Loading...
AR-14-270 Revision 1BUILDING ENERGY ANALYSIS REPORT PROJECT: Cabeza De Vaca Residence 52220 Avenida Rubio La Quinta, CA Project Designer: CITY OF LA QUANTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE 8300/5of JF Report Prepared by: Joan D. Hacker Insu-form, Inc. 77810 Las Montanas Road, Suite 201 Palm Desert, Ca 92211 760-345-1352 Job Number: Date: D 8/25/2015 £vl SSD The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number.' 2655 Run Code: 2015.08-25T11:08:35 ID: � 6o - (. 17 - V?o6 PERFORMANCE CERTIFICATE: Residential , Part 1 of 5 CF -1 R Project Name CabeZa De Vaca Residence Building Type-• m Single'Family ❑'Addition Alone 0 Multi'Family ® Existing+ Addition/Alteration Date 8/25/2015 Project Address 52220 Avenida Rubio. La Quinta . California Energy Climate Zone CA-Climate_Zone 15' . Total Cond. Floor Area 1;701 Addition 355 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ® No HERS Measures -- If Yes, A CF -4.R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2,of 5 of this form for details. INSULATION Area Special. Construction Type Cavity Features see Part.2 of 5 Status Slab Unheated Slab -on -Grade None 1,346 Perim ='180' Existing Wall Wood Framed R-11 1,503 Existing Roof Wood Framed Attic R-19 1,346 Existing Slab Unheated Slab -on -Grade None 355 Perim = 35' New Wall Wood Framed R-13 520 New Door Opaque Door None 40 New Roof Wood Framed Attic R-19 75 New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang . Sidefins Shades Status Front(VV) 90.0 0.710 0.73 2.0 none Bug.Screen Removed Left (N) 25.0 0.710 0.73 2.0 none Bug Screen Removed Rear (E) 107.4 0.710 0.73 2.0 none Bug Scieen Existing Right (S) 40.0 0.710 0.73 2.0 none Bug Screen Existing Skylight 9.0 0.710 0.73 none none None New Left (N) 60.0 0.650 0.60 2.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling. Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5. 1 by EnergySoft User Number. 2655 Run Code: 2015-08=25711:08:35 ID Page 3 of 11 PERFORMANCE CERTIFICATE Residential ;<:. k; Parti 2 -,of 5 ' CF -1 R Project Name Cabeza De Vaca Residence •, Building Type'.`. f® Single Family " ❑ Addition Alone ." ❑'Multi Family -® Existing+ Addition/Alteration 1812512015 Date SPECIAL FEATURES INSPECTION CHECKLIST ' The enforcement agency should pay special attention to the items;specified m this checklist These items,require special written justification and documentation, and special verification to be used,with th(e performance approach: The•enforcement agency determines the adequacy of.the justification, and may reject a_building or:design that otherwisecompliesbased on the adequacy of the special 'ustification and documentation submitted. _s. HERS REQUIRED VERIFICATION:. Items in this'section require -field testing and/or verification by a certified HERS.Rater: 'The -inspector must receive a completed CF -4R for'm for each of the measures. listed below`for:final to be riven. ' EnemyPro 5.1 by EnemySoft User Number: 2655 Run Code: 201508-25r11r08.35 ID.' Page 4 of 11 PERFORMANCE CERTIFICATE: ,ResidentialPart 3 of 5 CF -1 R Project Name 'B ilding'Type 'm'Single Family ❑ Addition,Alone . Date Cabeza De .Vaca Residence, 0 Multi Farr ily m Existing+ Addition/Alteration 1812512015 ANNUAL,ENERGY USE,,SUMMARY:f Standard '. Proposed Margin TDV kBtu/ft2- r Space Heating 12.41 •10.89 .1.52 Space Cooling 144.41 129.36 15.05 Fans 31.93 28.69 3.24 Domestic Hot Water 20.26 20.26 0.00 Pumps 0.00 0.00 0.00 Totals 209.01 189.20 19.81. Percent Better Than Standard: 9.5 i_ `. BUILDING ,COMPLIES NO„HERS'\%ERLFICA°TION REQUIRED . Fenestration Building Front Orientation: (149.270deq, Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (w) 570 0 Fuel Available at Site: Natural Gas (N) 700 60 Raised Floor Area: 0 (E) 650 107 Slab on Grade Area: 1,701 (S) 350 40 Average Ceiling Height: 9.0 Roof 1,430 9 Fenestration Average U -Factor: 0.69 TOTAL: 216 Average SHGC:, - 0.69 Fenestration/CFA: Ratio: 12.7% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Adnriniii [ative. Regulations and. Part 6 the Efficiency Standards of the California Gode'of Regulations: The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. 825!1015 Address 77810 Las Montanas Road, Suite 201 Name Joan D. Hacker Cit /State/Zi Palm Desert, Ca 92211 Phone -76073454352.,' Signed Date The individual with overall design responsibility, hereby certifies that the proposed building design represented in this set of construction documents is consistent with:the other, compliance°:forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, 'and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation instal lationzquality; and building envelope sealing require installer testing and certification,andfie Idverification by ari approved HERS rater. Designer or Owner (per Business- & Professions Code) Company Address Name City/State/Zip Phone Signed License # Date EnemyPro 5.1 by EnemySoft User Number: 2655 Runcode: 2015--08=`25TH:08:35 ID: Page 5 of 11 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Cabeza De Vaca Residence Building Type la Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1812512015 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 1,346 0.730 None 0 180 Existing 4.4.7-A1 Existing Living Wall 350 0.110 R-11 270 90 Existing 4.3.1-A2 Existing Living Wall 500 0.110 R-11 0 90 Existing 4.3.1-A2 Existing Living Wall 343 0.110 R-11 90 90 Existin 4.3.1-A2 Existing Living Roof 1,346 0.049 R-19 270 0 Existing 4.2.1-A4 Existing Living Wall 380 0.110 R-11 270 90 Removec 4.3.1-A2 Existing Living Wall 240 0.110 R-11 0 90 Removec 4.3.1-A2 Existing Living Wall 310 0.110 R-11 180 90 Existing 4.3.1-A2 Existing Living Slab 355 0.730 None 0 180 New 4.4.7-A1 Addition Wall 180 0.102 R-13 270 90 New 4.3.1-A3 Addition Door 40 1.450 None 270 90 New 4.5.1-A1 Addition Roof 75 0.048 R-19 270 0 New 4.2.1-A 16 Addition Wall 140 0.102 R-13 0 90 New 4.3.1-A3 Addition Wall 200 0.102 R-13 90 90 New 4.3.1-A3 Addition FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGCz Azm Status Glazing Type Location/Comments 1 Window 40.0 0.710 Default 0.73 Default 270 Removed Double Metal Clear Existing Living 2 Window 50.0 0.710 Default 0.73 Default 270 Removed Double Metal Clear Existing Living 3 Window 25.0 0.710 Default 0.73 Default 0 Removed Double Metal Clear Existing Living 4 Window 53.4 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 5 Window 4.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 6 Window 50.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 7 Window 40.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 8 Skylight 9.0 0.710 Default 0.73 Default 270 New Double Metal Clear Addition 9 Window 40.0 0.650 NFRC 0.60 NFRC 0 New Milgard Addition 10 Window 20.0 0.650 NFRC 0.60 NFRC 0 New Milgard Addition (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 1 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 5.0 10.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 6.8 8.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 1.0 4.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 5.0 10.0 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 8 None 1.00 9 Bu Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 EnergyPro 5.1 by EnergySoft User Number. 2655 Run Code: 2015-08-25711:08:35 ID: Pae 6 of 11 CERTIFICATE OF .COMPLIANCE: Ab!§identiaFPart 5.of 5 CF-1 R Project Name Cabeza De Vaca Residence Building Type. "0 Single Family ❑•Addition Alone 0 Multi Family, ® Existing+ Addition/Alteration Date 1812512015 BUILDING ZONE2 INFORMATION System Name Zone Name Floor'Area New Existinq Altered Removed Volume Year Built Living Zone Existing Living 1,346 12,114 1979 Addition 355 3,.195 Totals 1 3551 1,346 •• 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type . Min.,Eff.,, Thermostat Type Status Living Zone 1 Central Furnace ° '78% AFUE: Split Air Conditioner 12.0 SEER 'Setback Existing HVAC DISTRIBUTION System Name Heating Duct'. Cooling Duct Location R-Valle Ducts Tested? Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing 13 WATER HEATING SYSTEMS° S stem Name Qty. Type Distribution Rated Input Btuh Tank- Cap,' al" Energy Factor nor RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas No'Pipe,lnsulation 40,000 50 0;53 n/a n/a Existing MULTI-FAMILY WATER, HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ff c 0 Q ;� System Name Pipe Leri th Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried,-•— ❑: ❑• ' EnergyPro 5.1 by EnergySoft User Number. 2655 Run Code:.2015-08-25711:08:35 ' ID: Page 7 of 11 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Cabeza De Vaca Residence Date 1812512015 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (") below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pumpisolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACOA. §1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro5.1 by EnergySoft User Number: 2655 RunCode: 2015.08-25T11:08:35 ID: Page 8 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Cabeza De Vaca Residence 1812512015 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is.not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ftz or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 2655 Run Code: 2015-08-25711:08:35 ID: Page 9 of 11 MANDATORY- MEASURES SUMMARY: "Res"idential (Page 3 of 3 MF -1 R Project Name Date Cabeza De Vaca Residence 1812512015 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detachedgarages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2:_ Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occu aric "sensor. §150(k)11: Permanently installed. luminaires.located in rooms -or" areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy Iuimnaires.:EXCEPTION •1: Permanently installed low efficacy luminaires shall be allowed provided they,_are controlled by.either a'dimmer switch that complies with'the appiicable requirements of §119, or by a manual - on occupant sensor.that complies with the applicable.•, rbquirements;6t§119. EXCEPTION;2: Lighting inldetached storage building less than 1000 square feet located on a residential site'is not re wired to1c6m I witli 61.60k)i1. §150(k)12: Luminaires recessed'into insulated ceilings,shall be Iisted.for:zero clearance insulation.contact (IC) by, Underwriters . Laboratories or other nationallyrecogni2ed4estirig/rating laboratory; and have a label'that certifies -the lumiunaire is airtight with air leakage less then 2,0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be. sealed with a gasket or caulk between the luminaire housing and ceilin . §150(k)13: Luminaires providing) outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches,,which are`permanently.mounted to a residential building or'to other buildings on the same lot shall be higWefficacy. EXCEPTION 1- Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a,motion sensorrnot,having an override�or bypass switchahat disables the motion sensor, and one'of the following'controls: a photocontrol•not: having an override o0ypass.switch thaVdisables the photocontrol; OR an astronomical time clock not having an override ;orbypass switch that disables the astronomical time clock;. OR an energy management control system (EMCS) not having, an override:orbypass switch'that allows the luminaireao`be always qn EXCEPTION 2: Outdoor luminaires used to comply with Exception to', §150(k)'.13 maybe controlied'by a temporaryoverride, switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours.`EXCEPTION 3: Permanently installed. luminaires in or around swimming pool, water features, orothee location'subject to Article 680 of the California Electric Code need not be high efficacy luminaires.. §150(k)14: Internally illuminated address signs shall, comply. with Section 148; OR not contain a screw -base socket, and consume no more than five wafts of power, as determined according to §130 d'. §150(k)l5: Lighting!for parking lots and'carportsm with'4 total of for 8 or more vehicles per site shall complywith the applicable requirements in Sections 130, 132, 134, and 147.�Lighting for parking.garages for 8 or more vehicles shall comply with the applicable requirements of Sections 136,13i, 134:and 146: §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires:EXCEPTION Permanently:installed low efficacy luminaires shall be allowed provided that they are controlled by an occu ant sensor s -certified to com l` with the applicable requirements of 119. EnergyPrri 5.1 by EnergySoff User Number. 2655 RunCdde:- 2015-0&25T11:08:35 ID: Page 10 of 11 HVAC SYSTEM°HEATING 'AND,COOLING LOADS -SUMMARY. k Project Name _ Date Cabeza De Vaca Residence 8/25/2015 System Name Floor Area Living Zone 11701 ENGINEERING CHECKS SYSTEM LOAD; Number of S 'stems 1 COIL COOLING' -,CFM: Sensible Total Room Loads '.,963' .30,924 ' Return Vente ilghting 0 Return Air'Ducts 2,622 Return: Fan o Ventilation 0 0: Supply' -Fan 0 Supply. Air Ducts 2,622 TOTAL SYSTEM LOAD . 36,168. PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 70,000. 2,202 666 33,420 Total Out ut Btuh 70,000 Output Btuh/s ft 41.2 2,374 Cooling System 0 Output per System 58,000 0 0 0 Total Output Btuh 58,000 ' 2,202 0 Total Output ons 4.8 2,374 Total Output Btuh/s ft 34.1 Total Output s ft/Ton 351:9 38,169 Air S stem . CFM per System 1,300 ArHVAC EOUIPMENT,:;SELECTION- : r Airflow cfm 1,300: Existing. HVAC 46,990' : 0 70,000 Airflow cfm/s ft 0.76 ' Airflow cfmrron 269.0 Total Adjusted Output 46,990 (Adjusted for Peak Design'conditions) ' 0 70,000 Outside Air % 0.0 % Outside Air cfm/s ft 0.00 - ;. -TIME OF SYSTWPEAK, Aug 3 PM Jan 1 AM Note: values above given.atARI conditions . HEATING.SYSTEM:PSYCHROMETRICS- Airstream.Tem' eratures'at,Tiine.of Heatin' ;Peak' 26 OF 68 OF 68 OF 119OF F Outside Air 0 cfm Supply Fan Heating Coil . 117 °F 1,300 cfm ROOM 68 OF 70 OF COOLING SYSTEM PSYCH ROM ETICS' Airstream Tem &&tures at Time of-Coolk Peak 112 ! 78 OF 80 / 59 OF 80 / 59 °F • 46144 OF z Outside Air 0 cfm Supply Fan Cooling Coil 48145 OF 1,300 cfm 29.8% I ROOM 80 / 59 OF 78158 OF EnergyPro 5.1 by EnergySoft User Number: _2655 RunCode: 201508-25T11:08:35. ID:. = Page 11 of 11