Loading...
BCOM2019-0006 Revision 2taPERMIT Qa�tta - -- CALIFORNIA- -- # BCOM2019-006 PLAN LOCATION. MEETING ROOM - LEVEL 1 & 2 49-499 Eisenhower Dr. Project Address: La Quints, CA 92253 Project j t Description: - REMODEL EXISTING RETAIL AND OFFICE _ SPACE TO MEETING ROOMS. - ALTERATION: REVISED FLOOR PLANS AND _ PLUMBING PLANS TO REFLECT THE CHANGES TO FLOOR MOUNTED WATER CLOSETS APN #: 658190011 Applicant Name: Andrew Judd Address: 201 Main St. Suite 325 City, ST, Zip: Minneapolis, MN 55414 Telephone: 952-367-6414 Email: ajudd@cuningham.com Valuation of Project $ 1,600,000 Contractor Name: Orr Builders New SFD Construction: Address: 39-301 Badger Street, Suite 300 Conditioned Space SF City, St, Zip Palm Desert, CA 92211 Garage SF Telephone: (760) 360-6632 Patio/Porch SF Email: svance orrbuilders.com Fire Sprinklers SF State Lic: City Bus Lic: Architect/Engineer Name: Cuningham Group Construction Occupancy: A-3 Address: 201 Main St. Suite 325 Grading: City, St, zip Minneapolis, MN 55414 Telephone: 952-367-6414 Bedrooms: n/a Stories: 2 # Units: n/a Email: ajudd@cuningham.com State Lic: City Bus Lic: Property Owner's Name:La Quinta Resort & Club New Commercial / Tenant Improvements: Address: 49-499 Eisenhower Dr. Total Building 10,400 SF City, ST, Zip La Quinta, CA 92253 Construction Type: VA Occupancy: A-3 Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 Developing Visions into Landmarks Date: September 30, 2019 PROJECT: La Quinta Resort and Club ORR Job #:968-19 — Meeting Rooms a a I = Builders Request For Information RFI #18 W:q TO: Andy Judd — ajudd@cunnigham.com ❑ w � ATTN: UJ a � � o FROM: ORR Builders. > N CY g Project Manager: Steve Vance — svance �+�orrbuilders.com w n Site Superintendent: Scott Werry — swer"orrbuilders.com, Mike Ohrberg — Superintendant — mohrberg@orrbuilders.com () o C 6 Project Engineer: Melody Cser mcseiflorrbuilders.com w O c� Reference: Meeting Rooms — Plumbing Sheets Sheet/Detail: We are requesting the following information to be provided and/or Clarified; 1. Please proved plan change on the waste & vent system to accommodate the grounds for the toilets? New iso? RESPONSE NEEDED B Y: 10/3 RESPONSE: I EXP's response to RFI 018 SUBMITTED BY: Melody Cser Attached are the revised sheets showing the change from wall -mounted to floor -mounted water closets. These sheets also coordinate with other background changes. V. Manuzon / M. Hopf EXP 10/01/19 Answered by: Date: ORR Personnel: Date: a Please see the attached revised sheets A101.1, A102.1, P103.1, P104.1 and P501.1. Also included is the cutsheet for the revised water closet selection with a floor waste discharge. -Andy Judd, CGA, 10/01/2019 39.301 Badar Street, Suite 300. CA 92211* Ph: 760-360.6632 * Fax: 760-360-5591 * www.orrbuilders.com General Contractor * Lic. No AB 693077 SUBMITTAL REVIEW COMMENTS This review is only for conformance with the design concept of the project and LaQuinta Resort compliance with the information given in the Contract Documents. Corrections or comments made on the shop drawings/submittal data within this review do not relieve EXP Project # 2019006-00 the Contractor from compliance with the requirements of the Plans and Specifications. Approval of a specific item shall not include approval of an assembly EXP Log # Water Closets of which the item is a component. Contractor is responsible for dimensions to be confirmed and correlated at the job site, quantities, information that pertains solely to the fabrication processes or to the means of construction, coordination of the work of Date: Sept. 27, 2019 all trades and performing all work in a safe and satisfactory manner. It is the Page: 1 of 1 Contractor's responsibility to ensure all items requiring resubmission are addressed prior to ordering of such materials and to avoid delays in the project. Reviewed By: V. Manuzon / M. Hopf Water Closets Disposition: Approved as Noted Comments: 1. The water closet is approved. The core drills shall be provided per discussion. Please include the core drill for the vent for the water closet located inside the chase behind the fixture. 241 N. Broadway, Suite 203, Milwaukee, WI 53202, USA T: +1.414.221 0088 . www exp.com Madera'" FloWise®16-1/2" Height Elongated LESS EverClean® • Floor mount flushometer valve toilet • Vitreous china • High Efficiency, Low Consumption. Operates in the range of 1.1 gpf to 1.6 gpf (4.2 Lpf to 6.0 Lpf) • Meets definition of HET (High Efficiency Toilet) when used with a high efficiency flush valve (1.28 gpf or 1.6 / 1.1 gpf dual flush) • Fully glazed 2-1/8" trapway • Elongated bowl • 10" or 12" roughing -in • 16-1/2" rim height for accessible application • Condensation channel • Powerful direct -fed siphon jet action • 10" x 12" water surface area • 1-1/2" inlet spud • 2 bolt caps ❑ 3043.001 Elongated bowl only, top spud ❑ 3248.001 Elongated bowl only, top spud with slotted rim for bedpan holding ❑ 3249.001 Elongated bowl only, back spud System MaP* Score: • 1,000 grams of miso @ 1.1 gpf, 1.28 gpf or 1.6 gpf when used with an American Standard flush valve Maximum Performance (MaP) testing performed by IAPMO R&T Lab. MaP Report conducted by Veritec Consulting, Inc. and Koeller and Company. Component Parts: ❑ 047007-0070A Inlet Spud (furnished with bowl) ❑ 481310-100 Bolt caps with retainers (furnished with bowl) Nominal Dimensions: 718 x 356 x 419mm (28-1/4" x 14" x 16-1/2") Fixture only, less seat and flush valve Recommended working pressure —between 25 psi at valve when flushing and 80 psi static Compliance Certifications - Meets or Exceeds the Following Specifications: • ASME A112.19.2 / CSA B45.1 for Vitreous China Fixtures MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AD4 AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE BUILDING FACILITIES - CHECK LOCAL CODES. Madera"m FloWise° 16-1/2" Height Elongated Flushometer Toilet BARRIER FREE VITREOUS CHINA LESS EVERCLEAN® ® SEE REVERSE FOR ROUGHING -IN DIMENSIONS To Be Specified: ❑ Color: ❑ White ❑ Seat: ❑ American Standard #5901.100 Heavy duty open front less cover ❑ American Standard #5905.100 Extra heavy duty open front less cover ❑ Flushometer Valve: ❑ 1.6 gpf: ❑ Sensor -Operated: American Standard Selectronic® DC Power #6065.161.002 (Top Spud) ❑ Sensor -Operated: American Standard Selectronic° AC Power #6067.261.002 (Back Spud) ❑ Manual: American Standard #6047.161.002 (Top Spud) 1.28 gpf: Optional Flushometer valve Sensor -Operated: American Standard Selectronic' DC Power #6065.121.002 (Top Spud) ❑ Sensor -Operated: American Standard Selectronic® AC Power #6067.221.002 (Back Spud) ❑ Manual: American Standard #6047.121.002 (Top Spud) ❑ 1.6 / 1.1 gpf Dual Flush: ❑ Sensor -Operated: American Standard Selectronic® DC Power #6065.761.002 (Top Spud) M113 p CEO AMr�-N RM v 4-11 ENVIROMENTAL ADA WATER PRODUCT Wh.r_w dwith COMPLIANT EFFICIENT DECLARATION 1.1 or 1.28 gpf toilet flush valves © 2018 AS America Inc. spec_3043.001 Madera FW 16.51-leight-EL-Flushometer 11/18 Madera7m FloWise° 16-1/2" Height StaG Elongated Flushometer Toilet BARRIER FREE VITREOUS CHINA LESS EVERCLEAN® ® PART OF L l X 1 L 3043.001/3248.001 FINISHED WALL 102mm I - 4711mm (4") I 04-11ri 25mm I C/L OF SEAT POST HOLES 140mm (5-1/2') CENTERS 1• N.P.T*A 1' C-W.T. SUPPLY TO FLUSH VALVE 121mm� (43/4") 711mm l28'I 3artnvn—l—� I /'SPI1D 419 18-1/2') 1 3824"m r LFINISHED �r (14-1/4") FLOOR 150mm 2$4m� 13mm (5-7/W) (10•) (112") I 2(10') �1 (10 j C/L OF OUTLET 3249.001 (28-1/4•) 76mm 4ym 356mm ;3') 1- t18-fli') (14') G+1. OF SEAT POST HOLES 140mm (5-1/2') CENTERS -- ,r4p 438m ,1r.1/4'1 41, I f 18• I IR'1 I I 362mm j (14-1/4) FINISHED 25amr 150mm FLOOR 13mm Itb7M'y (1/2') 001m-� (10) C/L OF OUTLET -exp. ww.rw.`Ywr�n..rp�...wrt.w.riww. r w�wr r.tt.w►+..+'r �w..w+4..�w..�. w�.+.r, �.•� r�l N rnw. r. w rr.+nrww D 09/27/2019 sr V. Manuzon / M, Hopi s.. s"emmm a.sw"� comm.m. NOTES: PRODUCT 3043 SHOWN, 3248 SAME EXCEPT WITH SLOTTED RIM FOR BED PAN HOLDING. TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM BREAKER ON THE FLUSHOMETER VALVE, THE PLUMBER MUST VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING. THIS TOILET DESIGNED TO ROUGH -IN AT A MINIMUM DIMENSION OF 254MM (10") AND A MAXIMUM DIMENSION OF 305MM (12") FROM FINISHED WALL TO C/L OF OUTLET. FLUSHOMETER VALVE NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY. FLUSHOMETER VALVE REQUIREMENTS FOR 12" (305MM) ROUGH -IN: SWEAT EXTENSION NIPPLE IS REQUIRED. REFER TO VALVE MANUFACTURER AND LOCAL CODES. IMPORTANT: Dimensions of lixturas are nominal and may vary w,lhm the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages. M114 © 2018 AS America Inc. spec_3043.001 Madera FW 16.5Height-EL-Flushometer 11/18 WASHBROOKO FIoWIWO.125 GPF ULTRA HIGH EFFICIENCY URINAL SYSTEM SELECTRONIC® FLUSH VALVE n BARRIER FREE WASHBROOK® FloWise® 0.125 GPF ULTRA HIGH EFFICIENCY URINAL SYSTEM ❑ 6590.525 0.125 gpf Exposed Top Spud Urinal and Selectronic° Urinal Flush Valve URINAL: • Vitreous china • Ultra High Efficiency. Operates in the range of 0.125 gpf to 1.0 gpf (0.5 Lpf to 3.8 Lpf) • Flushing rim • Elongated 14" rim from finished wall • Washout flush action • Extended sides for privacy • 3/4" inlet spud • Outlet connection threaded 2" inside (NPTF) • Strainer included • Meets ASME flush requirements at 0.125 to 1.0 gpf • Model 6590.001 top spud SELECTRONIC® FLUSH VALVE: • Factory -Installed CR-P2 Lithium Battery • Pressure Compensation feature ensures accurate flush volume regardless of inlet water pressure • Self -Cleaning Piston with integral wiper spring significantly reduces clogging and maintenance • Selectronic® Proximity System with universal sensor provides hygienic, "hands free" operation • State -of -the -Art Electronics prevent ghost flushing • Dezincification Resistant semi -red brass alloy • Fully Mechanical Manual Override Button can flush the valve without power • Fail -Safe: Valve automatically closes upon loss of power or water pressure and does not need to be reset • Adjustable Sanitary Flush cleans the fixture & maintains the trap seal. • Stadium Feature: Valve automatically switches to water savings mode during periods of heavy usage • Chemical Resistant EPDM Seals for extended life • Adjustable Tailpiece for rough -in flexibility • Can be installed left or right handed • Model6063.013 Includes: • 2 Wall hangers • 3/4" I.P.S. angle stop with back -flow protection and vandal -resistant cap • Sweat solder kit including cover tube and wall flange • 3/4" High back pressure vacuum breaker, spud coupling and flange N35 SEE REVERSE FOR ROUGHING -IN DIMENSIONS High -Efficiency Urinal Systems: • 87.5% water savings when compared to a 1.0 gpf urinal system Battery Life: • 4 years @ 4,000 flushes per month Operating Pressure: 20 psi (flowing) - 80 psi (static) Flow Requirement: 10 gpm (37.9 L/min.) Nominal Fixture Dimensions: 360 x 480 x 664mm (14-1/8" x 18-7/8" x 26-1/8") m EPA G�`G Certified by KPMO RST © 2016 AS America Inc. spec_6590.525 Washbrook FW 0.125gpf Rev. B 8/16 I, WASHBROOKO FloWise°0.125 GPF �G ULTRA HIGH EFFICIENCY URINAL SYSTEM BARRIER FREE SELECTRONIC® FLUSH VALVE ® DETECTION ZONE 400mm-800mm FINISHED (15-3/4" TO 31-1/2") WALL 108-133mm �1 �� 64mm (4-1/4" to 5-1/4"J—". 1 ! ! (2-1/2") SUPPLY i (3/4DN 20P.S.) 15�n-� µ�; ._ . MANUAL •T..-.OVERRIDEBUTTON 293mm(11-1/2') 'CRITICAL LEV(1691/2 ) K2 HANGERS r360mm 8mm X 25mm -(5/16"X 1") SLOT 343mm(13-1/2") 480mm 438mm (18-7/8") 464mm (I7-1/4") (18-1/4") 664mm 26-1/8")REF. (-) (1/ 2') 1�x 83mm _I (3-1/4") / I ■ 432mm (17") MAX C/L OF 610mm 102mm (4„) OUTLET (24") OPTIONAL FINISHED FLOOR "Note: The Critical Line (-C-L-) on Vacuum Breaker must typically be a minimum of 6" (152mm) above fixture. Consult Codes for details. VALVE LEFT or RIGHT HAND INSTALLATION Fixture Compliance Certifications - Meets or Exceeds the Following Specifications: • ASME A112.19.2-2008/CSA 1345.1-08 for Vitreous China Fixtures Valve Listings: • ASSE 1037 • ANSI/ASME A112.19.2 • ADA Compliant PART OFLIXIL 2" N.P.T. FEMALE OUTLET CONNECTION 13mm_ (1/2") ? r r,t rf �" 1 1 r- \I� 13mm (1/2")� FINISHED WALL—' ,---GASKET 1 f 1 i 1 1 02mm—j (4 ) 2" N.P.T. INSIDE THREADS DETAIL OF OUTLET CONNECTION .❑MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES -CHECK LOCAL CODES. • When installed so top of rim is 432mm (17") MAXIMUM from finished floor. NOTES: PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard At 12.19.2. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages. N36 © 2016 AS America Inc. spec_6590.525 Washbrook FW 0.125gpf Rev. B 8/16