Loading...
003014 (SFD) Compaction Reportt s,^ Buena Engineers, Inc. 11 40 AN EARTH SYSTEMS, INC. COMPANY 1731-A WALTER STREET August 13, 1987 VENTURA, CALIFORNIA 93003 R.L. Harmon, M.D. 43-576 Washington Street Palm Desert, CA 92260 Project: 53-945 Rubio La Quinta, California Subject: Report of Field Densities Single Family Residence (805) 642-6727 B7 -0038-P1 87-8-733 RECE E AUG 2's 1 @87 CITE' OF LA QUINTA PLANNING & DEVELOPMENT DEPT. On June 27 and 30, 1987, a representative of our firm performed density tests in the fill for the house pad on the above referenced project. Tests were performed at random locations, in accordance with ASTM D 2922-81 and ASTM D 3017-78 Nuclear Density Test Procedure. Tests were performed as per authorization of R.L. Harmon, M.D. The estimated locations of the tests are presented on the attached plan with their results being summarized on the attached test report sheet. A total of three (3) density tests were performed. Tests results indicate that after reworking areas of low density, a minimum of ninety. (90)' percent* relative compaction has been obtained within the areas tested. The maximum density -optimum moisture were determined in the laboratory in accordance with ASTM D 1557-78, Method A or C. Test results are as follows: Soil Description USCS Brown silty fine to medium coarse sand with gravel SM/SP VENTURA (805) 642-6727 121.9 pcf 10.27 LANCASTER (805) 948-7538 BAKERSFIELD SANTA BARBARA PALM SPRINGS SAN LUIS OBISPO (805)327-5150 (805)966-9912 (619)328-9131 (805)544-6187 August 13, 1987 -2- B7-0038-P1 87-8-733 1. The project is located on the west side of Avenida Rubio, one 0) lot north of Calle Chillon in the City of La Quinta, California. 2. Prior to our arrival at the site, the fill had been placed. 3. First testing indicated low density. 4. On June 30, 1987, the failure was retested. 5. The purpose of testing was to observe compliance with the minimum requirements of the City of La Quinta, California. Limitations This firm did not perform a soils investigation, did not conduct any tests to determine the general condition, adequacy or stability of soils on the property, nor did it observe the backfilling or compacting operations which were already completed at the time our personnel were called to the site. The only services performed were the specific moisture and density tests summarized in this report. These test results provide only limited information about the surface materials observed at the locations and depths tested and cannot be relied upon for information about subsurface conditions or compaction, or to determine the appropriateness of any design or construction of improvements on the site. No inspection was made of the contractor's work and no guarantee or warranty of that work in backfilling or compaction of the soils on the site is made or implied. If there are any questions, please do not hesitate to contact this office. Respectfully submitted, BUENA ENGINEERS., NC. Phillip . Clanton PDC/JRV/mea HD Copies: 4 - R. L. Harmon, M.D. 2 - City of La Quinta 1 - P. 5. 2-VTAfile Reviewed a )6.4 1) � V � 2 Joseph R. Ven Civil Engineer BUENA ENGINEERS, INC. /Rpf ESSIpN9! p 00 F2 too. C 041210 a Exp. 7.p-11 1� U � c lmx. � BUenn Engineers,im. REPORT OF RELATIVE COMPACTIONS CONTRACTOR: ADDRESS: August 13, 1987 Job No. DATE: Report No. JOB &LOCATION: La Quinta, CA B7 -0038-P1 87-8-733 TEST NO. DATE TESTED DESCRIPTION °e MOISTURE IN PLACE DRV DENSITY IN PLACE RELATIVE COMPACTION MAXIMUM DENSITY 53-945 Rubio 1 6-22-87 Per Plan 1.0 BSG 13.7 103.8 85* 121.9 2 6-22-87 Per Plan FSG 12.2 115.8 95 121.9 3 6-30-87 I Retest 0 1 11.3 114.1 93** 121.9. = Falling Test = Passing Retest BSG = Below Subgrade FSG = Finish Subgrade WE CERTIFY THAT THESE TESTS WERE PERFORMED IN CONFORMANCE WITH COPIES BUENA ENGINEERS, INC. ti , • Q O � V VV j L".G!_11 Li�lL.1_!JN S3 --9 4.5 2u 3 t p LL b,U i I TGA CA BUENA ENGINEERS, INC. r R�� If7 • � DATE: FILE N0.370038/4/