07-0402 (GRES) Revision 1•-o
Bin #
�',
City of La Quinta
Building & Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address:
G
V/7j5,L/,,6�Z
Owner's Name:
A. P. Number:
Address:
Legal Description:City,
ST; Zip: ��
Contractor:i/
inG
y =
Address:
T1 a
Project Description: ff�/p��
City, ST, Zip:
' f
C I J/A /4 U G� Z !/ Al z
Telephone:
C
State Lic. # :
City Lic. #:
iV`A, OAU
Arch., Engr., Designer:
Address:
City, ST, Zip:
Telephone:
i` !
Construction Type: Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
State Lic. #:
Name of Contact Person:
��v �
Sq. Ft.:
#Stories:
# Units:
Telephone # of Contact Person: 7460
5 a - -
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Rec'd
TRACKING .
PERMIT FEES
Plan Sets
Plan Check submitted
IV?j
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Cheek Deposit
Truss Calcs.
Called Contact Person
Plan Cheik Balance
Energy Calcs.
Plans picked up
Construcion
Flood plain plan
Plans resubmitted
Mechanicsil
Grading plan'
2"" Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
''d Review, ready for correctio su
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
h a
School Fees
1
Total Per in Fees R
.
Lt Ito (74J64 - porq{ -M "ve.
35,E
W_q imp fo:
TITLE 24 REPORT
t
Title 24 Report for:
Van Patten Residence
54-940 Avenida Rubio;:
La Quinta, Ca: 92254V.`K-��
Project Designer:
Bob Sipovac
72651 Theodora.
Palm Desert, Ca 92254
760-567-2347
Report Prepared By:
Sipovac Construction Inc.�r.
Sipovac Construction
72651 Theodora Lane
Palm Desert, CA 92260
(760) 779-0790
Job Number, CITY 'OF LA QUINTA
BUILDING & SAFETY DEPT.
!' 262006 APPROVED
FOR CONSTRUCTION
Date: DATF,
10/1/2007
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report: This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building -Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro4.3 by EnergySoft Job Number., 2620.06. User Number. 52W771
S
t�
TABLE OF CONTENTS
i
Cover Page
Table of Contents
Form. CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
Form WS -5R Residential Kitchen Lighting
1
2
3'
a
10
EnergyPro 4.3 by Energysoft Job Number. 262006 User Number. 5289
Certificate Of Compliance: Residential
(Part 1 of 4) CF -1 R
-Lan-Patten-Besidence
Existing Floor Area:
1,950.
10L1./gn
Project Title
_54=9_40-Avenid.aRuhit- La_Quinza
0
ft2
Date
Project Address
ft2
Average Ceiling Height:
Building Permit #
�ipavac_Cgnstr-uction
Number of Dwelling Units:
(760) 779-0790
Documentation Author
Telephone
plan Check/Date
-Ene0
EJ
CAClimate Zo[ies5
Field Check/Date
Complia ce Method
Climate Zone
TDV Standard
Proposed
Compliance
(kBtu/sf-yr) Design
Design
Margin
Space Heating 2.11
9.58
-7.47
Space Cooling 58.88
49.56 '
9.31
Fans. 8.31
7.06
1.25
Domestic Hot Water 11.67
11.94
-.0.26
Pumps 0.00
0.00
-0.00
Totals 80.97
78.14
2.83
Percent better than Standard:
113.5%
Building Type: Single Family
❑ Multi Family
Building Front Orientation:
Fuel Type:
Fenestration:
❑ Addition
Existing + Add/Alt
(W) 270 deg
Natural Gas
Area: 203 ft2 Avg. U: 0.37
Ratio: 10.4% Avg. SHGC: 0.30
BUILDING ZONE INFORMATION
Zone Name _ Floor Area Volume
Zone 1 -----1,950 5 600
OPAQUE SURFACES Insulation Act.
Type Frame Area U -Fac. Cay. Cont. Azm
Total Conditioned Floor Area:
1,950
ft2
Existing Floor Area:
1,950.
ft2
Raised Floor Area:
0
ft2
Slab on Grade Area:
1,950
ft2
Average Ceiling Height:
8.0
ft
Number of Dwelling Units:
1.00
Number of Stories: 1
# of Thermostat Vent
Units Zone Type _ Type Hgt. Area
X00_ Conditioned- -Setback- 2 --nla
Gains Condition
Tilt Y / N Status JA IV Reference
Location / Comments
Wall Wood- 186_ -0102 R_13 -R--0-O-90__9.0
-Nall- Wood_ __29A- _0_102. _R=13- _R-O.O-1.8.0_ 9.0
-Wa-L- Wood_ 224 0102_-R,3-_EZ0_0 X70 9D
Door- None_ 21_ -OMD- None_ _R=0_U -27.0-9D
-Wall_ Wood- _28B_ 0.102 _R--13 --R--O-O- .0 90
-Roof_ Wood _1..950_ _0-025_ J�-3.8- _R-0.0-0- 0
IX
X
X
IN
X
a
[-]Altered--
❑Altered_
❑Alterert_
0
❑Altered_
❑❑Altered-
09=A3�E 0G_A21_ Zane,
09=A3 (E=09-42)_ Zone_1
02A3-(F-=OQ-A2) z 1
Existing_ 28=A4 Zane I
_0.9 A3_(F=0Q=A9 Zone.1
_01=A1.8-(E=01-A4)Zaae 1
❑
❑
EJ
n
I
❑
M
❑❑
Run Initiation Time: 10/01/07 17:17:53 Run Code: 1191284273
I EnergyPro 4.3 by EnergySoft User Number: 5289 Job Number: 262006 Page:3 of 10
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
Van Patten. Residence_ 10/1/2007
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments
1_ W-tndow---Bear_(E)-- X24 -0 3ZO-NERD-0.44 -NERC
2 Window Rear (E)_ 42.0 0.350 NFRC 0_22 NFRC
_90_ m.0-Nevlt_Milgatd-lider
90 90 New Anderson Sliding door
Zone 1
Zone 1
3
Window
Rear
(EL 16.0.
0.470 NFRC 0_29. NERC
90
90 New Milgard Fixed
Zone 1
4
Window
Rear
(E) 16.0
0.370 NFRC 0_44 NFRC
90
90 New Milgard Slider
Zone 1
5
Window
Rear
(E) 12.0
1.280 116-A 0_80 116-B
90
90 RemovedSingle Metal Clear
Zone 1
6
Window
Rear
(E) 12.0
1.280 116-A 0_80 116-B
90
90 RemovedSingle Metal Clear
Zone 1
L
8
Wio_dow Rear.(E)- 42.0
Window Rear (E) 12.0
0_790. 116-A QM. 116-B
1.280 116-A 0.80 116-B
90_
90
-0 Eeem2vecQoub.Le Metal.Tinted.
90 RemovedSingle Metal Clear
_Zone 1.
Zone 1
9
Window
Right
(S) 12.0
1.28 116-A 0_80 116-B
180
90 RemovedSingle Metal Clear
Zone 1
1Q
Window
Right
(S) 12.0
1_280 116-A 0_80 11CB
180
90 RemovedSingle Metal Clear
Zone 1
11
Window
Right
(SL 42.0
0.350 NFRC 0_22 NFRC
180
90. New Anderson Sliding. door
Zone 1
12
Window
Front
(W) 12.0
0.370 NFRC 0_44 NFRC
270
90 New Milgard Slider
Zone 1
13
1Niadow F-roat_(WJ 7-5
047-0_NFR-C-0-2S 1VFBC
-27-0L
-90- New Milgatd-Fixed
Zone 1
14
Window
Front
(W) 7.5
0.470.NFRC 0_29 NFRC
270
90 New Milgard Fixed
Zone 1
15
Window
Front
(W) 12.0
1.280 116-A 0_80 116-B
270
90 RemovedSingle Metal Clear
Zone 1
16
Window
Front
(W) 12.0
1.280 116-A 0_80 116-6
270
90 RemovedSingle Metal Clear
Zone 1
17
_Window
Left
(N) 42.0
0.320 NFRC 0_30 _NERC
• 0
90 New Anderson french door
Zone 1
18
Window
Left
(N) 2.0
0.480 NFRC 0.61 NFRC
0
90 Existing Glass block
Zone 1
19
Window
Left
(Vl)_ 2.0
0_480 NFRC 0.61 NFRC
0
90IStingGal ss block
Zone 1
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B
INTERIOR AND EXTERIOR SHADING
Window Overhang Left Fn Right Fin -
#
Exterior Shade Type
SHGC Hgt. Wd. Len. H t. LEA REA Dist Len Hgt Dist Len Hgt
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen -
_
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
T,-
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14.
Bug Screen
0.76
15
Bug Screen
0.76
16
Bug Screen
0.76
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES
Insulation
R -Val. Location
Condition Location/
JA IV Reference Status Comments
EnergyPro 4.3 by EnergySoft User Number. 5289 Job Number. 262006 Pane:4 of 10
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
Van Paften. Residence. 10/1/200.7
Project Title Date
FENESTRATION SURFACES
True' Cond. Location/
# Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments
20 -Window—Left. (N)- _20 —OAaO-NERC 0 6] -NERC _0_ _9.0 Existing_Glass.btadi Zone 1.
1. Indicate source either from NFRC or Table 116A.
2. Indicate source either from NFRC or Table 11611.
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin. Right Fin
# Exterior Shade Tvpe SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len Hgt Dist Len Hgt
20 Bug Screen 0.76
HERMAL MASS FOR HIGH MASS DESIGN
Area. Thick. Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES Insulation `11 Condition Location/
Type Length R -Val. Location JA IV Reference Status Comments
EnergyPro 4.3 by EnergySoft User Number. 5289 Job Number. 262006
_ Paoe: 5 of 10 I
Certificate Of Compliance: Residential
(Part3 of 4)
- CF -IR
Van. Patten. Residence.
Project Title
Rated
10/1./20.0.7.
Date
HVAC SYSTEMS
Location
Heating
Type
Minimum
Eff
Cooling
Type
Minimum Condition
Eff Status
Thermostat
Type
Zone 1
Electric
0.80 HSPF
Split Air Conditioner
14.0 SEER New
Setback
Standard Gas, 50 gal or Less. Small Gas. No. Pipe- Insulation
1. 40,0.00
50,
New 0.57
n/a n/a
HVAC- DISTRIBUTION
-
Location
Heating
Cooling
Duct .
Location
Duct Condition
R -Value Status
Ducts
Tested?
Zone 1
Ducted
Ducted.
Outdoors
8.0. NEW
Yes
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
WATER HEATING SYSTEMS
Rated
Tank
Energy
Tank Insul.
Water Heater
# in Input
Cap.
Condition Factor
Standby R -Value
System Name Type Distribution
Syst. (Btu/hr)
(gal)
Status -or RE
Loss (%) Ext
Standard Gas, 50 gal or Less. Small Gas. No. Pipe- Insulation
1. 40,0.00
50,
New 0.57
n/a n/a
Multi -Family Central Water Heating. Details
Hot Water Pump
Hot Water Piping Length (ft) Add 1/2"
In Plenum. Outside- Buried In£Ulation
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with TWO 24, Parts 1 and 6 of the California Code of
Regulations; and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, €nsulation installation quality, "
and building envelope sealing require installer testing and certification and field verification by an approved HERS rafer.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: Name: Sipovac Construction Inc.
Title/Finn: Bob Sipovac Title/Firm: Sipovac Construction
Address: 72651 Theodora. Address: 72651 Theodora Lane
Palm DesertCa 92254 Palm DesertCA 92260
Telephone, 760-567- 47 Lic. #: Telep 760 77A-0790
!CJ R �<v
(signature) (d to ' (signature
(d te)
Enforcement Agency
Name:
Title/Firm:
Address: _
Telephone:
(signature) (date)
Certificate Of Compliance : Residential (Part4 of 4) CF -1-R
Nan. Patten Residence_ 1.0/l/2001
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to.the items specified in this checklist. These.items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
oases on me aaequacy OT the special jusuncauon ana aocumentation suomittea.
Plan I Field
The Roof 'R-38 Roof Attic" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual.
w •
HERS Required Verification
Items in this section require field testing and/or verification_ by a certified home energy rater under the supervision of a
.._.._ �.
...0 ..rr..,..............y
Plan .Field
The HVAC System "Zone 1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documentec on the CF -4R. -
Run Initiation Time: 10/01/0717:17:3 Run Code: 1191284.273
EnergyPro 4.3 by EnergySoft User Number. 5289 Job Number: 262006 Page:7 of 10
Mandatory Measures- Summary: Residential (Page.- I of 2) MF -1-R
NOTE: .Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approa•:,r used. More stringent compliance
requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this cher :dist is incorporated into the permit
documents, the featuresnotedshall be considered by all parties as minimum componentperformance specifications for tie mandatory measures whether.
they are shown elsewhere in the documents or on this checklist only.
Check or initial applicable boxes or check NA if not applicable and included with tate
1:1
El
ENFORCE -
length recirculating sections of hot•water pipet sht)I! be jneyliilted.to Table 150B.
DESCRIPTION permit application documentation.
NIA
DESIGNER MENT
2. Coaling i ystem piping (suction, chilled watpr;'or pane llrje8) p!Flt!Q 1h N!ated between heating source and
Building Envelope Measures .
❑
❑
indirect hot water tank shall be insulated to Table .110 B,ijjld:Eg411Ioh 150=A.
§'150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling,
y
❑
Q
❑
❑
§ 150(b): Loose fill insulation manufacturer's labeled R -Value:
❑
❑
❑
❑
§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑
❑X
❑ `
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
apply to, exterior mass walls).
❑ '
❑
entirety in conditioned space. .
�§ 150(d): Minimum'R-13 raised floor insulation in framed floors or equivalent U -factor.
❑ .
❑
❑
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
EnergyPro 4.3 by EnergySoft User Number: 5289 Job Number. 262006
,
1. Masonry and factory -built fireplaces have:
a. closable metal or glass door covering the entire opening of the firebox
❑
❑X
❑
b. outside air intake with damper and control, flue damper and control
❑
C91
❑
2- No continuous burning gas pilot lights'allowed.
❑
0
❑
§ 150(f): Air retarding wrap installed to comply with §151 meets requirements specked in the ACM Residential Manual.
❑
❑
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑
❑
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑
, ❑
' permeance rate no greater than 2.0 perm/inch.
§ 118: Insulation specified or installed meets, insulation installation quality standards. Indicate type and include
❑
❑
El
Form:
§ 116-17: Fenestration Products, Exterior Doors, and I�Itration/Exfihretion Controls.
4 a 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
z
0
El
❑
2.~ Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
❑
❑
❑
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped: all joints and penetrations caulked and sealed.
❑
❑
❑
Space Conditioning, Water Heating and Plumbing System Measures f
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
Q
❑
§ 150(h): Heating and/or cooling, loads*calculated in accordance with ASHRAE, SMACNA or RCCA.
❑
❑
❑ •,
`§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
i
❑
❑X
❑
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
❑
❑
❑
having an installed thermal resistance of R-12 or greater.
2. Back-up tanksfor solal.ar systems, ynf red storage tanks, or other indirect hot water tanks have R-12 external
El
El
insulation or R 1(3internal insulation 6I1�} Indlcateq on the exterior of the tank showing,the R -value.
:.; �
3. The fgllovAgg piping is insulated according to Taitple 150,A/P qr Equation 150-A Insulation Thickness:
..
1. First 5 feet of hot and cold waterk-cis apw. t to water Opp.tor tflnk non -recirculating systems, and entire
1:1
El
11
length recirculating sections of hot•water pipet sht)I! be jneyliilted.to Table 150B.
2. Coaling i ystem piping (suction, chilled watpr;'or pane llrje8) p!Flt!Q 1h N!ated between heating source and
❑
❑
❑
indirect hot water tank shall be insulated to Table .110 B,ijjld:Eg411Ioh 150=A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑
❑
5. insulation must be protected.from damage, including that due to sunlight, moisture, equipment maintenance,
❑
❑
❑
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
❑ '
❑
entirety in conditioned space. .
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑
❑
❑
-
EnergyPro 4.3 by EnergySoft User Number: 5289 Job Number. 262006
Page:8 Of 10
Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance app oath used. More stringent
compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if iot
applicable.
ENFORCE -
N/A DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
2. System is installed with:
1. All duds and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604,
❑ ❑ ❑
605, and Standard 6-5; supply -air and retum-air duds and plenums are insulated to a minumum installed level of
b. Cover for outdoor pools or outdoor spas.
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure s -stem
3. Pool system has directional inlets and a circulation pump time switch.
that meets the applicable requirements of UL 181, UL 181A; or UL 181 B or aerosol sealant that meets the requirements
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh
burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
or tape shall be used.
§ 118 (): Cool Roof material meets specified criteria
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other thar
❑ ❑ ❑
sealed sheet metal, dud board or flexible duct shall not be used for conveying conditioned air. Building cavities and,_
§ 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Tat le
support platforms may contain ducts. Duds installed in cavities and support platforms shall not be compressed to cause
150-0, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are
reductions in the cross-sectional area of the duds.
electric and have an output frequency no less than 20 kHz. ,
3. Joints and seams of duct systems and their components shall not be sealed with doth back rubber adhesive
El El Eldud
tapes unless such tape is used in combination with mastic and draw bands.
luminaire has factory installed Hlp ballast.
4. Exhaust fan systems have back draft or automatic dampers.
❑ ❑ ❑
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually opening
❑ ❑ ❑
dampers.
provided that these luminaires ale controlled by switches separate from those controlling the high efficacy luminaires
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
❑ ❑ ❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
ark Controlled by an occupant sensors) cettfieq to comply with Section 119(d).
retardant and provides shielding from solar radiation that can cause degradation of the material.
§ 150(k)4: Permgh6ht�y installed luminaires located other than n kichens, bathrooms ggarages, laundry rooms, and utility rooms
shall be.high efficacy luminaires (except closets less than 70 ) OR are controlled by a dimmer switch OR are
7. Flexible duds cannot have porous inner cores.
❑ ❑ ❑
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
❑ ❑ ❑
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
❑ ❑ ❑
b. Cover for outdoor pools or outdoor spas.
❑ ❑ ❑
3. Pool system has directional inlets and a circulation pump time switch.
❑ ❑ ❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑ ❑ }❑,
burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118 (): Cool Roof material meets specified criteria
❑ ❑ Q
Lighting Measures
§ 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Tat le
❑ ® ❑
150-0, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are
electric and have an output frequency no less than 20 kHz. ,
§ 150(k)1: HIGH EFFICACY LUMINAIRES -.OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ ❑ ❑
luminaire has factory installed Hlp ballast.
§ 150(k)2: Permanently installed luminaires'in'kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as, determhed
❑ X❑ ❑
in Section 130(6), of perrrianentty installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires ale controlled by switches separate from those controlling the high efficacy luminaires
§ 150(k)3: Perrnarigntly installed luminaires in ,,,. nom§; garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑ � ElOR
ark Controlled by an occupant sensors) cettfieq to comply with Section 119(d).
§ 150(k)4: Permgh6ht�y installed luminaires located other than n kichens, bathrooms ggarages, laundry rooms, and utility rooms
shall be.high efficacy luminaires (except closets less than 70 ) OR are controlled by a dimmer switch OR are
❑ ❑ ❑
controlled by an occupant sensor that complies With Sechdo ( 9(d) that does not tum on automatically or have an
always on option. -
§ 150(k)5: Luminaires that are recessed into -.insulated ceilings are apprgved for.z grq'clearance insulation cover (tC) and are
E3 11 Elcertified
to ASTM E283 and labeled aS:air fight (AT) toles' at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ ❑ ❑
same lot shall be high efficacy luminaires (not including lighting around swimming pools/Water features or other Arficll;
680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 1194).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑ ❑ ❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑ ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section
119(d).
EnergyPro 4.3 by EnergySoft User Number. 5289 Job Number. 262006
Page: 9 of 10
Residential Kitchen Lighting. Workshe=et WS -5I
Van Patten Residence 10/1/2007
Project Title Date
At least 50%0 of the total rated wattage of permanently Installed luminaires In kitchens must be In luminaires that are high efficacy luminaires
as defined in Table 150-0. Luminaires that are not high efficacy must be switched separately.
Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed In kitchens.
High Efficacy
Luminaire Type High Efficacy? Watts Quantity Watts Other Watts
(1) 16w Compact Fluorescent 2D Yes X No 23.0 x 1 = 23 or
(1) 22w Fluorescent Circline Rapid Start Yes X I No I 27.0 x 4 = 108 or
Yes I No x = or
Yes No x = or.
Yes No x =
or
Yes I No x or
Yes I No x = or
Yes No. x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x or
Yes No x = or
Yes No x = or
Total A: 131 B: 0
COMPLIES IF A,--- B YES Al NO I
I
EnergyPro 4.3 by EnergySoft User Number: 5289 Job Number: 262006 Page 10 of 10