Loading...
07-0402 (GRES) Revision 1•-o Bin # �', City of La Quinta Building & Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: G V/7j5,L/,,6�Z Owner's Name: A. P. Number: Address: Legal Description:City, ST; Zip: �� Contractor:i/ inG y = Address: T1 a Project Description: ff�/p�� City, ST, Zip: ' f C I J/A /4 U G� Z !/ Al z Telephone: C State Lic. # : City Lic. #: iV`A, OAU Arch., Engr., Designer: Address: City, ST, Zip: Telephone: i` ! Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo State Lic. #: Name of Contact Person: ��v � Sq. Ft.: #Stories: # Units: Telephone # of Contact Person: 7460 5 a - - Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING . PERMIT FEES Plan Sets Plan Check submitted IV?j Item Amount Structural Calcs. Reviewed, ready for corrections Plan Cheek Deposit Truss Calcs. Called Contact Person Plan Cheik Balance Energy Calcs. Plans picked up Construcion Flood plain plan Plans resubmitted Mechanicsil Grading plan' 2"" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''d Review, ready for correctio su Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue h a School Fees 1 Total Per in Fees R . Lt Ito (74J64 - porq{ -M "ve. 35,E W_q imp fo: TITLE 24 REPORT t Title 24 Report for: Van Patten Residence 54-940 Avenida Rubio;: La Quinta, Ca: 92254V.`K-�� Project Designer: Bob Sipovac 72651 Theodora. Palm Desert, Ca 92254 760-567-2347 Report Prepared By: Sipovac Construction Inc.�r. Sipovac Construction 72651 Theodora Lane Palm Desert, CA 92260 (760) 779-0790 Job Number, CITY 'OF LA QUINTA BUILDING & SAFETY DEPT. !' 262006 APPROVED FOR CONSTRUCTION Date: DATF, 10/1/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report: This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building -Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro4.3 by EnergySoft Job Number., 2620.06. User Number. 52W771 S t� TABLE OF CONTENTS i Cover Page Table of Contents Form. CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting 1 2 3' a 10 EnergyPro 4.3 by Energysoft Job Number. 262006 User Number. 5289 Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R -Lan-Patten-Besidence Existing Floor Area: 1,950. 10L1./gn Project Title _54=9_40-Avenid.aRuhit- La_Quinza 0 ft2 Date Project Address ft2 Average Ceiling Height: Building Permit # �ipavac_Cgnstr-uction Number of Dwelling Units: (760) 779-0790 Documentation Author Telephone plan Check/Date -Ene0 EJ CAClimate Zo[ies5 Field Check/Date Complia ce Method Climate Zone TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.11 9.58 -7.47 Space Cooling 58.88 49.56 ' 9.31 Fans. 8.31 7.06 1.25 Domestic Hot Water 11.67 11.94 -.0.26 Pumps 0.00 0.00 -0.00 Totals 80.97 78.14 2.83 Percent better than Standard: 113.5% Building Type: Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition Existing + Add/Alt (W) 270 deg Natural Gas Area: 203 ft2 Avg. U: 0.37 Ratio: 10.4% Avg. SHGC: 0.30 BUILDING ZONE INFORMATION Zone Name _ Floor Area Volume Zone 1 -----1,950 5 600 OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm Total Conditioned Floor Area: 1,950 ft2 Existing Floor Area: 1,950. ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 1,950 ft2 Average Ceiling Height: 8.0 ft Number of Dwelling Units: 1.00 Number of Stories: 1 # of Thermostat Vent Units Zone Type _ Type Hgt. Area X00_ Conditioned- -Setback- 2 --nla Gains Condition Tilt Y / N Status JA IV Reference Location / Comments Wall Wood- 186_ -0102 R_13 -R--0-O-90__9.0 -Nall- Wood_ __29A- _0_102. _R=13- _R-O.O-1.8.0_ 9.0 -Wa-L- Wood_ 224 0102_-R,3-_EZ0_0 X70 9D Door- None_ 21_ -OMD- None_ _R=0_U -27.0-9D -Wall_ Wood- _28B_ 0.102 _R--13 --R--O-O- .0 90 -Roof_ Wood _1..950_ _0-025_ J�-3.8- _R-0.0-0- 0 IX X X IN X a [-]Altered-- ❑Altered_ ❑Alterert_ 0 ❑Altered_ ❑❑Altered- 09=A3�E 0G_A21_ Zane, 09=A3 (E=09-42)_ Zone_1 02A3-(F-=OQ-A2) z 1 Existing_ 28=A4 Zane I _0.9 A3_(F=0Q=A9 Zone.1 _01=A1.8-(E=01-A4)Zaae 1 ❑ ❑ EJ n I ❑ M ❑❑ Run Initiation Time: 10/01/07 17:17:53 Run Code: 1191284273 I EnergyPro 4.3 by EnergySoft User Number: 5289 Job Number: 262006 Page:3 of 10 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Van Patten. Residence_ 10/1/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments 1_ W-tndow---Bear_(E)-- X24 -0 3ZO-NERD-0.44 -NERC 2 Window Rear (E)_ 42.0 0.350 NFRC 0_22 NFRC _90_ m.0-Nevlt_Milgatd-lider 90 90 New Anderson Sliding door Zone 1 Zone 1 3 Window Rear (EL 16.0. 0.470 NFRC 0_29. NERC 90 90 New Milgard Fixed Zone 1 4 Window Rear (E) 16.0 0.370 NFRC 0_44 NFRC 90 90 New Milgard Slider Zone 1 5 Window Rear (E) 12.0 1.280 116-A 0_80 116-B 90 90 RemovedSingle Metal Clear Zone 1 6 Window Rear (E) 12.0 1.280 116-A 0_80 116-B 90 90 RemovedSingle Metal Clear Zone 1 L 8 Wio_dow Rear.(E)- 42.0 Window Rear (E) 12.0 0_790. 116-A QM. 116-B 1.280 116-A 0.80 116-B 90_ 90 -0 Eeem2vecQoub.Le Metal.Tinted. 90 RemovedSingle Metal Clear _Zone 1. Zone 1 9 Window Right (S) 12.0 1.28 116-A 0_80 116-B 180 90 RemovedSingle Metal Clear Zone 1 1Q Window Right (S) 12.0 1_280 116-A 0_80 11CB 180 90 RemovedSingle Metal Clear Zone 1 11 Window Right (SL 42.0 0.350 NFRC 0_22 NFRC 180 90. New Anderson Sliding. door Zone 1 12 Window Front (W) 12.0 0.370 NFRC 0_44 NFRC 270 90 New Milgard Slider Zone 1 13 1Niadow F-roat_(WJ 7-5 047-0_NFR-C-0-2S 1VFBC -27-0L -90- New Milgatd-Fixed Zone 1 14 Window Front (W) 7.5 0.470.NFRC 0_29 NFRC 270 90 New Milgard Fixed Zone 1 15 Window Front (W) 12.0 1.280 116-A 0_80 116-B 270 90 RemovedSingle Metal Clear Zone 1 16 Window Front (W) 12.0 1.280 116-A 0_80 116-6 270 90 RemovedSingle Metal Clear Zone 1 17 _Window Left (N) 42.0 0.320 NFRC 0_30 _NERC • 0 90 New Anderson french door Zone 1 18 Window Left (N) 2.0 0.480 NFRC 0.61 NFRC 0 90 Existing Glass block Zone 1 19 Window Left (Vl)_ 2.0 0_480 NFRC 0.61 NFRC 0 90IStingGal ss block Zone 1 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B INTERIOR AND EXTERIOR SHADING Window Overhang Left Fn Right Fin - # Exterior Shade Type SHGC Hgt. Wd. Len. H t. LEA REA Dist Len Hgt Dist Len Hgt 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen - _ 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 T,- Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14. Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation R -Val. Location Condition Location/ JA IV Reference Status Comments EnergyPro 4.3 by EnergySoft User Number. 5289 Job Number. 262006 Pane:4 of 10 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Van Paften. Residence. 10/1/200.7 Project Title Date FENESTRATION SURFACES True' Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments 20 -Window—Left. (N)- _20 —OAaO-NERC 0 6] -NERC _0_ _9.0 Existing_Glass.btadi Zone 1. 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11611. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin. Right Fin # Exterior Shade Tvpe SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len Hgt Dist Len Hgt 20 Bug Screen 0.76 HERMAL MASS FOR HIGH MASS DESIGN Area. Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation `11 Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments EnergyPro 4.3 by EnergySoft User Number. 5289 Job Number. 262006 _ Paoe: 5 of 10 I Certificate Of Compliance: Residential (Part3 of 4) - CF -IR Van. Patten. Residence. Project Title Rated 10/1./20.0.7. Date HVAC SYSTEMS Location Heating Type Minimum Eff Cooling Type Minimum Condition Eff Status Thermostat Type Zone 1 Electric 0.80 HSPF Split Air Conditioner 14.0 SEER New Setback Standard Gas, 50 gal or Less. Small Gas. No. Pipe- Insulation 1. 40,0.00 50, New 0.57 n/a n/a HVAC- DISTRIBUTION - Location Heating Cooling Duct . Location Duct Condition R -Value Status Ducts Tested? Zone 1 Ducted Ducted. Outdoors 8.0. NEW Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status -or RE Loss (%) Ext Standard Gas, 50 gal or Less. Small Gas. No. Pipe- Insulation 1. 40,0.00 50, New 0.57 n/a n/a Multi -Family Central Water Heating. Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" In Plenum. Outside- Buried In£Ulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with TWO 24, Parts 1 and 6 of the California Code of Regulations; and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, €nsulation installation quality, " and building envelope sealing require installer testing and certification and field verification by an approved HERS rafer. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Sipovac Construction Inc. Title/Finn: Bob Sipovac Title/Firm: Sipovac Construction Address: 72651 Theodora. Address: 72651 Theodora Lane Palm DesertCa 92254 Palm DesertCA 92260 Telephone, 760-567- 47 Lic. #: Telep 760 77A-0790 !CJ R �<v (signature) (d to ' (signature (d te) Enforcement Agency Name: Title/Firm: Address: _ Telephone: (signature) (date) Certificate Of Compliance : Residential (Part4 of 4) CF -1-R Nan. Patten Residence_ 1.0/l/2001 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to.the items specified in this checklist. These.items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies oases on me aaequacy OT the special jusuncauon ana aocumentation suomittea. Plan I Field The Roof 'R-38 Roof Attic" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. w • HERS Required Verification Items in this section require field testing and/or verification_ by a certified home energy rater under the supervision of a .._.._ �. ...0 ..rr..,..............y Plan .Field The HVAC System "Zone 1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documentec on the CF -4R. - Run Initiation Time: 10/01/0717:17:3 Run Code: 1191284.273 EnergyPro 4.3 by EnergySoft User Number. 5289 Job Number: 262006 Page:7 of 10 Mandatory Measures- Summary: Residential (Page.- I of 2) MF -1-R NOTE: .Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approa•:,r used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this cher :dist is incorporated into the permit documents, the featuresnotedshall be considered by all parties as minimum componentperformance specifications for tie mandatory measures whether. they are shown elsewhere in the documents or on this checklist only. Check or initial applicable boxes or check NA if not applicable and included with tate 1:1 El ENFORCE - length recirculating sections of hot•water pipet sht)I! be jneyliilted.to Table 150B. DESCRIPTION permit application documentation. NIA DESIGNER MENT 2. Coaling i ystem piping (suction, chilled watpr;'or pane llrje8) p!Flt!Q 1h N!ated between heating source and Building Envelope Measures . ❑ ❑ indirect hot water tank shall be insulated to Table .110 B,ijjld:Eg411Ioh 150=A. §'150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling, y ❑ Q ❑ ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ ` 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed apply to, exterior mass walls). ❑ ' ❑ entirety in conditioned space. . �§ 150(d): Minimum'R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ . ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. EnergyPro 4.3 by EnergySoft User Number: 5289 Job Number. 262006 , 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ C91 ❑ 2- No continuous burning gas pilot lights'allowed. ❑ 0 ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specked in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ , ❑ ' permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets, insulation installation quality standards. Indicate type and include ❑ ❑ El Form: § 116-17: Fenestration Products, Exterior Doors, and I�Itration/Exfihretion Controls. 4 a 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. z 0 El ❑ 2.~ Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped: all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures f § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ Q ❑ § 150(h): Heating and/or cooling, loads*calculated in accordance with ASHRAE, SMACNA or RCCA. ❑ ❑ ❑ •, `§ 150(i): Setback thermostat on all applicable heating and/or cooling systems. i ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanksfor solal.ar systems, ynf red storage tanks, or other indirect hot water tanks have R-12 external El El insulation or R 1(3internal insulation 6I1�} Indlcateq on the exterior of the tank showing,the R -value. :.; � 3. The fgllovAgg piping is insulated according to Taitple 150,A/P qr Equation 150-A Insulation Thickness: .. 1. First 5 feet of hot and cold waterk-cis apw. t to water Opp.tor tflnk non -recirculating systems, and entire 1:1 El 11 length recirculating sections of hot•water pipet sht)I! be jneyliilted.to Table 150B. 2. Coaling i ystem piping (suction, chilled watpr;'or pane llrje8) p!Flt!Q 1h N!ated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table .110 B,ijjld:Eg411Ioh 150=A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. insulation must be protected.from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ' ❑ entirety in conditioned space. . 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ - EnergyPro 4.3 by EnergySoft User Number: 5289 Job Number. 262006 Page:8 Of 10 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance app oath used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if iot applicable. ENFORCE - N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 2. System is installed with: 1. All duds and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and retum-air duds and plenums are insulated to a minumum installed level of b. Cover for outdoor pools or outdoor spas. R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure s -stem 3. Pool system has directional inlets and a circulation pump time switch. that meets the applicable requirements of UL 181, UL 181A; or UL 181 B or aerosol sealant that meets the requirements § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) or tape shall be used. § 118 (): Cool Roof material meets specified criteria 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other thar ❑ ❑ ❑ sealed sheet metal, dud board or flexible duct shall not be used for conveying conditioned air. Building cavities and,_ § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Tat le support platforms may contain ducts. Duds installed in cavities and support platforms shall not be compressed to cause 150-0, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are reductions in the cross-sectional area of the duds. electric and have an output frequency no less than 20 kHz. , 3. Joints and seams of duct systems and their components shall not be sealed with doth back rubber adhesive El El Eldud tapes unless such tape is used in combination with mastic and draw bands. luminaire has factory installed Hlp ballast. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually opening ❑ ❑ ❑ dampers. provided that these luminaires ale controlled by switches separate from those controlling the high efficacy luminaires 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water ark Controlled by an occupant sensors) cettfieq to comply with Section 119(d). retardant and provides shielding from solar radiation that can cause degradation of the material. § 150(k)4: Permgh6ht�y installed luminaires located other than n kichens, bathrooms ggarages, laundry rooms, and utility rooms shall be.high efficacy luminaires (except closets less than 70 ) OR are controlled by a dimmer switch OR are 7. Flexible duds cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ }❑, burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (): Cool Roof material meets specified criteria ❑ ❑ Q Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Tat le ❑ ® ❑ 150-0, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. , § 150(k)1: HIGH EFFICACY LUMINAIRES -.OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed Hlp ballast. § 150(k)2: Permanently installed luminaires'in'kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as, determhed ❑ X❑ ❑ in Section 130(6), of perrrianentty installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires ale controlled by switches separate from those controlling the high efficacy luminaires § 150(k)3: Perrnarigntly installed luminaires in ,,,. nom§; garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ � ElOR ark Controlled by an occupant sensors) cettfieq to comply with Section 119(d). § 150(k)4: Permgh6ht�y installed luminaires located other than n kichens, bathrooms ggarages, laundry rooms, and utility rooms shall be.high efficacy luminaires (except closets less than 70 ) OR are controlled by a dimmer switch OR are ❑ ❑ ❑ controlled by an occupant sensor that complies With Sechdo ( 9(d) that does not tum on automatically or have an always on option. - § 150(k)5: Luminaires that are recessed into -.insulated ceilings are apprgved for.z grq'clearance insulation cover (tC) and are E3 11 Elcertified to ASTM E283 and labeled aS:air fight (AT) toles' at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/Water features or other Arficll; 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 1194). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number. 5289 Job Number. 262006 Page: 9 of 10 Residential Kitchen Lighting. Workshe=et WS -5I Van Patten Residence 10/1/2007 Project Title Date At least 50%0 of the total rated wattage of permanently Installed luminaires In kitchens must be In luminaires that are high efficacy luminaires as defined in Table 150-0. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed In kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 16w Compact Fluorescent 2D Yes X No 23.0 x 1 = 23 or (1) 22w Fluorescent Circline Rapid Start Yes X I No I 27.0 x 4 = 108 or Yes I No x = or Yes No x = or. Yes No x = or Yes I No x or Yes I No x = or Yes No. x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x or Yes No x = or Yes No x = or Total A: 131 B: 0 COMPLIES IF A,--- B YES Al NO I I EnergyPro 4.3 by EnergySoft User Number: 5289 Job Number: 262006 Page 10 of 10