Loading...
BWFE2019-0267Date: 12/30/2019 Application Number: BWFE2019-0267 Property Address: 78745 AVENIDA ULTIMO APN: 770092006 Application Description: STAUBER / 70LF GARDEN WALLS AND (3) COLUMNS Property Zoning: Application Valuation: $6,000.00 Applicant: ALFREDO ALVIDREZ - BLOCKWORKS INC DBA A A MASONRY 77-700 DELAWARE PLACE PALM PALM DESERT, CA 92211 Owner: JEFFERY & SUSAN STAUBER 78745 AVENIDA ULTIMO LA QUINTA, CA 92253 Contractor: BLOCKWORKS INC DBA A A MASONRY 77-700 DELAWARE PLACE PALM PALM DESERT, CA 92211 (760)360-7388 Llc. No.: 804168 Detail: 70LF OF 6' GARDEN WALL WITH (3) PILASTERS AT PROPERTY LINES, [ANGELUS 5-1.0, 5-1.1, AND 5-1.9 LQ SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. 2016 CALIFORNIA BUILDING CODES. t A FINANCIAL DESCRIPTION INFORMATION ACCOUNT CITY AMOUNT WALL/FENCE - FIRST 10OLF 101-0000-42404 0 $53.67 DESCRIPTION ACCOUNT CITY AMOUNT WALL/FENCE - FIRST 100LF PC 101-0000-42600 0 $67.08 Total Paid for BLOCK WALL 2019: $120.75 DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 cocW 0ati11r��(I — ceNt of,b, or�sear — PERMIT # 3W FEzo tq — 0 2-(v-I PLAN LOCATION: Project Address: M Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: (�LP...+. S a� c � �� III -� �• Applicant Name: A�� I a �� r� >r4 cob —4.5 Address: -� 700 Of City, ST, Zip: AA -e- Sr Telephone: 3 t L L Email: a\CA OAyl S o ` - J Valuation of Project $ ry-) Contractor Name: New SFD Construction: Address: 27706 &"Lc Conditioned Space SF City, St, Zip Garage SF Telephone: t i Patio/Porch SF Email: t } Fire Sprinklers SF State Lic: ' �y City Bus ,ic:.�U 6 Arch/Eng Name:44 Construction Type: Occupancy: Address: Grading: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: S—rA\.)3Ee— New Commercial / Tenant Improvements: Address: VU Total Building SF City, ST, Zip ! r.� * Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Req'd Rec'd Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License Neighbor Approval Letter for Block Wall Construction DATE: /VIC, .,_. WALL CONSTRUCTION ADDRESS: 787LK AnAJA UG-Am4v int� , ��a 5Z2�3 -., have been made aware of my neighbor's block wall construction project. I have seen or have had explained to me the proposal made by my neighbor and/or AA Masonry, to erect a wall at this address. NEIGHBOR'S NAME & ADDRESS (PRINTED CLEARLY WITH PHONE NUMBER) J/GL L� STE7.A-,' PHONE: 0--��� f NEIGHBOR'S SIGNATURE: RECEIVED DEC 302019 CITY OF LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT -bWm .ol`t-o2G7 gel Chi 5�- i n C MY IT9'7 4 5 iAG` a1 '70 L.F �\A s\.� MP r�a_,z block aG v\-,\M I S O L < L6 r a 19� N 0 v- 'o 1 A I'L m *�n�.INC ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL BEARING PRESSURE = 1500paf 3. ALLOWABLE SOIL PASSIVE PRESSURE = ITCt 4. COEFFICIENT OF FRICTION - 0.25, COHESION Opaf 5, CAN71UVER ACTIVE a. 3Opcf 6. MASONRY COMPRESSIVE STRENGTH, fm - 1500pai. SPECIAL INwECTION NOT REQUIRED PER CBC SECTION 1704.2. EXCEPTION 2. 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES: 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 12. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD —DRAWN STEEL WIRE CONFORMING TO ASTM A951, PROVIDE MINIMUM 6 INCH LAP SPLICES. 13. STRENGTH OF CONCRETE FOR FOOTINGS — 2500pa1 0 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4, CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPUT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE —AND —GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE -USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E—x MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270. OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E-2 MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. S. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000pa1. 7. FIRST COURSE MAY BE WET —SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. B. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-0"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED 10. GROUT ALL CELLS WITH REINFORCEMENT. 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE, B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK —OUT DETAILS SEE DETAIL SHEET S-5.1. 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE MASONRY FENCE WALL SCHEDULE 'H' MAX. X BARS 15' LONG CYLI ur LGNG CMII 'B' MIN. 6 —0 4048 o.e. 4054 o.c. 1 —11 6'—B" 4040"o.e. 4045"o.c. 2'—l" 7'-4 032"0.c. 4036"o.c. B —0"I &024"o.c. 4027"o.c. GHL INC ARCHITECTURE - ENGINEERING 228 East Badillo Street I Covina. CA 91723 T: 626,938 1595 F: 626. 11485 8' to 8' High Site Wall Concentric Spread Footing C ® 110mph iulta Risk Category I W Wide CMU OPTIONAL WALL CAP rSTTI. LADDER TYPE 5 STD FOR SLUMPSTONE)— JOINT REINF. AT TOP COURSE, AT FIRST COURSE, AND 24"o.c. 6" WIDE (NOM.) CMU GROUT CELLS — w/ REINF. X W 'X' BARS PER Z SCHEDULE 0 = CTR. OF WALL] o_ OWLS. TO MATCH VERT. REINF. LAP 24" MIN. F.G. WET —SET FIRST COURSE 2-#4 CONT — CONT. CONC. FTC. ALT. BENDS— — CITY OF LA QUINTA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY: A. DATE: 09/21/2018 o! w a N 3" CLR. TYP. G E�XP. 9-30-20 C 1 V \ F% OF CAS DATE SIGNED 9-10-18 S-1.OLQ #16-077 K CO., I C.BLOCSI ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL BEARING PRESSURE — 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE - ISOpcf 4. COEFFICIENT OF FRICTION - 0.25, COHESION - Opsf 5. CANTILEVER ACTIVE — 30pd 6. MASONRY COMPRESSIVE STRENGTH, f'm — 1506pa1. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES: 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER, CENTER VERTICAL BARS IN CELLS. 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD —DRAWN STEEL HARE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. 3. STRENGTH OF CONCRETE FOR F0011NGS = 2500pa1 0 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE —AND —GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDE❑ MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000ps1. 7. FIRST COURSE MAY BE WET —SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. B. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-0"ox. OR 20'—O"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED 10, GROUT ALL CELLS WITH REINFORCEMENT. 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK —OUT DETAILS SEE DETAIL SHEET S-5.1. 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE MASONRY FENCE WALL SCHEDULE 'H' MAX. X BARS 18- LONG F 1: LONG C4U 'B' MIN. 6 —0 4048 o.c. 4054 o.c, 2 —6 6'—B" 4040"o.c. 4045"o.c. 2 —9 7'-4 4032"o:c, 4036"ox. 3'-0" 024"o.c. 4027'o.c. 3'-3' GHL INC. ARCHITECRAF , ENGINEERING 228 East eadillo Street I Covina, CA 91723 T: 626 938.3595 F: 626,938 0485 _ WWW1111k Cd:-4> 6' to 8' High Site Wall Eccentric Spread Footing C o 110mph (ult) Risk Category I W wide CMu OPTIONAL WALL CAP 5TTD LADD' �15 SIU FOR JOINT REINF, 1 COURSE, AT F COURSE, AND 6" WIDE (NOM, GROUT CELLS w/ REINF. 'X' BARS PER SCHEDULE 0 CTR. OF WALL OWLS. TO MAT VERT. REINF. L 24" MIN. FC WET —SET FIRSI COURSE 2-04 CON T. CONT. CONC. F CITY OF LA QUINTA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY: A. DATE: 09/21/2018 F'LK SGHLUULE DATE SIGNED 9-10-18 S-1.1LQ #16-077 Al&4 BLOCK COL, INC. !Inca If46 ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL BEARING PRESSURE — 1500pof 3, ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4, COEFFICIENT OF FRICTION + 0.25, COHESION — Opsf 5. CANTILEVER ACTIVE - 30pcf 6. MASONRY COMPRESSIVE STRENGTH, f m - 1500psi. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2. EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES: 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 2. NOT USED. 8'-8" to 8'-8" High Pilaster Spread Footing Seismic, 5% o 1 second 1W or ZV CMU Pilaster OPTIONAL WALL CAP CMU PILASTER, SOLID GROUT (16" SHOWN) 3. STRENGTH OF CONCRETE FOR FOOTINGS - 2500psi • 26 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS 2—#4 VERT. BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. B. GROUT SHALL CONFORM TO ASTM C476, WITH AN B-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000ps1. 7. FIRST COURSE MAY BE WET —SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. B. NOT USED. 9. PROVIDE EXPANSION / CONTROL JOINT ON EACH SIDE OF PILASTER WHERE INTERSECTING BLOCK WALLS OCCUR. 10. NOT USED. 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. OPTIONAL ADHERED VENEER (MAX WEIGHT-10psf) MAY BE APPLIED TO EACH FACE OF PILASTER. INSTALLATION BY OTHERS. MECHANICALLY —ANCHORED VENEER IS NOT PERMITTED. 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE 16616 OR 16616 MASONRY PILASTER SCHEDULE PILASTER, SOLID C. H W MAX. IN, 6'-6" 16 2 —9 4 24" 3'-4` 5 7'-4. 16" 3 —0 4 24" 3 —B 5 16" 3" 3- 5 24" 1 —O 6 LOADING 1. SEISMIC, 5% DAMPING • 1 SECOND ACCELERATION Cs-0.33Wt. 2. SEISMIC LOADING EXCEEDS ALL WIND LOADING FOR EXPOSURE C, 130mph AND LESS. 'W -16" SQ. W 2—#4 w 3I"OUTSIDE FACE 3" OUTSIDE FACE OF BLOCK TO - OF BLOCK TO t. OF VERT ¢. OF VERT OWLS. TO MATCH VERT. REINF. LAP —� 24" MIN. EQ F.G WET —SET FIRST - COURSE LONG EA. WAY CONC. FTG. B" WIDE (NOM.) CMU PILASTER, SOLID GROUT ALL CELLS A PILASTER SECTION GHL INC. ARCHITECTURE - ENGINEERING 228 East Willo S[reel I Covina, CA 91723 T: 626.938 1595 F: 626-938 0485 _ ww"!, Iiwr-kr EN r h" 1 EQ. � P Y � N _ 3" CLR. 'B' SQUARE MIN. TYP. PER SCHEDULE CITY OF LA QUINTA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY: A. DATE: 09/21/2018 Frpt _�0)0. NZ1 1= L11ff-ir-7 # EXP. 9-30-20 * � C1V41. '�• P DATE SIGNED 9-10-18 S--1.9LQ #16-077