BRES2015-0193 Revision 2�M&00
Bin #
Qty of La Quinta
Building K Safety Division
Permit #
- 78-495 Cal[6 Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Project Address:
0 (fOO e—T- Ownrr'sNamc:
A. P. Number:
Address:
Legal Description: L'0-F (�o TL,
City, ST, Zip:
Contractor: V1 7—
Telephone:
Address:
Project Description:
City, ST, Zip:
Telephone:
un
State Lic.
City City Lic.
Arch., Engr., Designer
Address:
'4L
City, ST, Zip:
Telephone:
----------
•Construction Type: Occupancy:
State Lic. #:
. . . . . . . . Project type (circle one): New Add'n Alter Repair
Demo
Name of Contact Person:
Sq. Ft.: # Stories: # Units:
Telephone # of Contact Person:
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
Submittal Req'd
Rec'd TRACKING PERMIT FEES
Plan Sets
Plan Check submitted Item
Amount
Structural Cales.
Reviewed, ready for corrections
Plan Check Deposit
Truss CaIcs.
Called Contact Person
Plan Check Balance
Title 24 CaIcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2"' Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.T.
H.O.A. Approval
Plans resubmitted
Grading
IN If OUSE:-
Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees,
Total Permit Fees
12
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATA ill/Wb BY= 0 c
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McGourty Residence Calculation DatefTime: 16:46, Thu, May 05, 2016
Calculation Description: Title 24 Analysis Input File Name: McGourty-Mike Mendoza -Jody Jones-15.xml
CFI R-PRF-01
Page 1 of 12
GENERAL INFORMATION
01
Project Name
McGourty Residence
02
Calculation Description
Title 24 Analysis
03
Project Location
81-788 Couples Court
04
City
La Quinta
05
Standards Version
Compliance 2015
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2013-4 (744)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6 6
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
170
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
3938
15
Number of Zones
4
16
Slab Area (ft2)1
3938
17
Number of Stories
1
18
Addition Cond. Floor Area
N/A
19
Natural Gas Available
Yes
20
Addition Slab Area (ft2)
N/A
21
Glazing Percentage (%)
21 9%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
ihis building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
5.74
5,77
-0.03
-0.5%
Space Cooling
135.83
128.82
7.01
5.2%
IAQ Ventilation
1.04
1.04
0.00
0.0
Water Heating
6.52
7.26
-0.74
-11.3
Photovoltaic Offset
--•
0,00
000
—
Compliance Energy Total
149.13
142.89
6.24
4.2
Registration Number: 216-N0169435A-000000000-0000 Registration Date/flme: 2016-05-0516:58:20 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-05 16:47:34
RECEIVED
MAY 0 6 2016
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
MAY
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: McGourty Residence Calculation Daterrime: 16:46, Thu, May 05, 2016 Page 2 of 12
Calculation Description: Title 24 Analysis Input File Name: McGourty-Mike Mendoza -Jody Jones-15.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Exposed slab floor in conditioned zone
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
Minimum Airflow
• Verified EER
Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
• -- None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on -site renewable energy system.
Reference Energy Use
Energy Design Rating
Margin
Percent Improvement
Total Energy (kTDV/f2-yr)•
188.02
181.78
6.24
3.3
• includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03 1
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
McGourty Residence
3938
1
6
4
3
1
Registration Number: 216-N0169435A-000000000-0000 Registration Date/Time: 2016-05-0516:58:20 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-05 16:47:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McGourty Residence Calculation Daterrime: 16:46, Thu, May 05, 2016
Calculation Description: Title 24 Analysis
Input File Name: McGourty-Mike Mendoza -Jody Jones-15.xml
CF1 R-PRF-01
Page 3 of 12
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ftz)
Avg, Ceiling
Height
Water Heating System 1
Water Heating System 2
master bedroom
Conditioned
HVAC 11
976
9
DHW Sys 1
kit living
Conditioned
HVAC 22
1290
9
DHW Sys 1
bedroom
Conditioned
HVAC 33
980
9
DHW Sys 1
Garage Zone
Conditioned
HVAC 44
692
1 9
1 DHW Sys 1
OPAQUE SURFACES
01
02 1
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
80d Wall
master bedroom
R-21 Wall (W21 2x6.16)
80
Right
980
67.9
90
170d Wall
master bedroom
R-21 Wall (W21 2x616)
170
Front
560
20.1
90
260d Wall
master bedroom
R-21 Wall (W.21.2x6.16)
260
Left
500
0
90
350d Wall
master bedroom
R-21 Wall (W21.2x6.16)
350
Back
420
180
90
Roof
master bedroom
R-38 Roof Attic
976
80d Wall 2
kit living
R-21 Wall (W.21.2x6.16)
80
Right
575
23
90
170d Wall 2
kit living
R-21 Wall (W.21 2x6.16)
170
Front
475
104
90
260d Wall 2
kit living
R-21 Wall (W21 2x6.16)
260
Left
460
96
90
350d Wall 2
kit living
R-21 Wall (W.21.2x6.16)
350
Back
960
247
90
Roof 2
kit living
R-38 Roof Attic
1290
80d Wall 3
bedroom
R-21 Wall (W21 2x6.16)
80
Right
630
0
90
170d Wall 3
bedroom
R-21 Wall (W.21.2x6 16)
170
Front
300
25
90
250d Wall
bedroom
R-21 Wall (W.21.2x6.16)
250
-specify-
1300
48.9
90
260d Wall 3
bedroom
R-21 Wall (W.21.2x6.16)
260
Left
18
0
90
350d Wall 3
bedroom
R-21 Wall (W.21.2x6.16)
350
Back
360
72
90
Roof 3
bedroom
R-38 Roof Attic
980
80d Wall 4
Garage Zone
R-21 Wall (W21,2x6.16)
80
Right
350
24
90
170d Wall 4
Garage Zone
R-21 Wall (W21.2x6.16)
170
Front
250
162
90
260d Wall 4
Garage Zone
R-21 Wall (W21.2x6 16)
260
Left
260
0
90
Roof 4
Garage Zane
R-38 Roof Attic
692
Registration Number: 216-NO169435A-000000000-0000 Registration Date/Time: 2016-05-0516:56:20 HERS Provider: CaICERTS ina
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-05 16:47:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McGourty Residence Calculation Daterrime: 16:46, Thu, May 05, 2016
Calculation Description: Title 24 Analysis
Input File Name: McGourty-Mike Mendoza -Jody Jones-15.xmi
CF1 R-PRF-01
Page 4 of 12
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic master bedroom
Attic Roofmaster bedroom
Ventilated
3
01
085
No
No
Attic kit living
Attic Roofkit living
Ventilated
3
0 1
0.85
No
No
Attic bedroom
Attic Roofbedroom
Ventilated
3
0 1
0.85
No
No
Attic Garage Zane
Attic RoofGarage Zone
Ventilated
3
01
0.85
No
No
Registration Number: 216-N0169435A-000000000-0000 Registration Date/flime: 2016-05-0516:58:20 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-0516:47:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McGourty Residence Calculation DateITime: 16:46, Thu, May 05, 2016
Calculation Description: Title 24 Analysis
Input File Name: McGourty-Mike Mendoza -Jody Jones-15.xml
CF1 R-PRF-01
Page 5 of 12
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multiple
er
Area
(ft2)
U-factor
SHGC
Exterior Shading
new B
Window
80d Wall (Right-80)
-
1
2.3
0.29
0.35
Insect Screen (default)
new B 2
Window
80d Wall (Right-80)
-
----
1
2.3
0.29
0.35
Insect Screen (default)
new B 3
Window
80d Wall (Right-80)
---
-
1
2.3
0.29
0.35
Insect Screen (default)
new F
Window
80d Wall (Right-80)
-
--
1
30.0
0.32
0.24
Insect Screen (default)
new G
Window
80d Wall (Right-80)
----
----
1
6.0
0.32
024
Insect Screen (default)
new H
Window
80d Wall (Right-80)
----
-
1
25.0
0.31
026
Insect Screen (default)
new 17
Window
350d Wall (Back-350)
-
-
1
180.0
0.32
0.23
Insect Screen (default)
new E
Window
80d Wall 2 (Right-80)
----
-
1
23.0
0.29
0.35
Insect Screen (default)
new A
Window
170d Wall 2 (Front-170)
----
-
1
32.0
0.31
0.21
Insect Screen (default)
new 01
Window
170d Wall 2 (Front-170)
-
----
1
40.0
0.71
0.60
Insect Screen (default)
new A 2
Window
170d Wall 2 (Front-170)
----
-
1
32.0
0.31
0.21
Insect Screen (default)
new A 3
Window
260d Wall 2 (Left-260)
-
1
32.0
031
0.21
Insect Screen (default)
new 16
Window
260d Wall 2 (Left-260)
-
1
32.0
0.32
023
Insect Screen (default)
new A 4
Window
260d Wall 2 (Left-260)
-
-
1
32.0
0.31
0.21
Insect Screen (default)
new 07
Window
350d Wall 2 (Back-350)
-
1
23.0
1032
0.23
Insect Screen (default)
new E 2
Window
350d Wall 2 (Back-350)
-
-•-
1
200.0
0.29
0.35
Insect Screen (default)
new 08
Window
350d Wall 2 (Back-350)
-
1
24.0
0.32
0.23
Insect Screen (default)
new 18
Window
170d Wall 3 (Front-170)
-
----
1
25.0
029
0.35
Insect Screen (default)
new B 4
Window
250d Wall (- specify --250)
---
----
1
2.3
0.29
0.35
Insect Screen (default)
new B 5
Window
250d Wall (- specify --250)
---
-
1
12.3
0.29
0.35
Insect Screen (default)
new B 6
Window
250d Wall (- specify --250)
-
--
1
2.3
0.29
0.35
Insect Screen (default)
new C
Window
250d Wall (- specify --250)
--
-
1
6.0
0.29
0.35
Insect Screen (default)
new C 2
Window
250d Wall (- specify --250)
--•-
-
1
6.0
0.29
0.35
Insect Screen (default)
new D
Window
250d Wall (- specify --250)
-
----
1
15.0
0.29
0.35
Insect Screen (default)
new D 2
Window
250d Wall (- specify --250)
•---
--
1
15.0
0.29
0.35
Insect Screen (default)
new 06
Window
350d Wall 3 (Back-350)
-•-•
---
1
72.0
10.32
1 0.23
Insect Screen (default)
Registration Number: 216-N0169435A-000000000-0000 Registration Date/Time: 2016-05-05 16:58:20 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-05 16:47:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McGourty Residence Calculation DatefTime: 16:46, Thu, May 05, 2016
Calculation Description: Title 24 Analysis
Input File Name: McGourty-Mike Mendoza -Jody Jones-15.xmi
CFI R-PRF-01
Page 6 of 12
DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door 12
170d Wall
201
0.50
Door 15
80d Wall 4
24.0
0.50
Door 13
170d Wall 4
81.0
0.08
Door 114
170d Wall 4
81.0
0,08
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofmaster bedroom
Attic Roofs
Wood Framed Ceiling
n 0.(.
none
0 644
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
Inside Finish: Gypsum Board
• Cavity/Frame: R-21 /2x6
Exterior Finish: Wood
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofkit living
Attic Roofs
Wood Framed Ceiling
in. O.G.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofbedroom
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofGarage Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Registration Number: 216-NO16943SA-000000000-0000 Registration Date/Time: 2016-05-05 16:58:20 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-05 16:47:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McGourty Residence Calculation Daterrime: 16:46, Thu, May 05, 2016
Calculation Description: Title 24 Analysis
Input File Name: McGourty-Mike Mendoza -Jody Jones-15.xml
CFI R-PRF-01
Page 7 of 12
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
master bedroom
976
119
None
08
No
Covered Slab 2
kit living
1290
102
None
0.8
No
Covered Slab 3
bedroom
980
153
None
0.8
No
Slab
Garage Zone
692
86
None
0
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
WATER HEATING SYSTEMS
01
02
03
04
05 06
Name
System Type
Distribution Type
Water Heater
Number of Heaters Solar Fraction (%)
DHW Sys 1 - 1/2
DHW
Pipe Insulation, All Lines
DHW Heater 1
2 .0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
066
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/2
�-
—
—
—
—
Registration Number: 216-N0169435A-000000000-0000 Registration Date/Time: 2016-05-05 16:58:20 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-0516:47:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McGourty Residence Calculation Date/Time: 16:46, Thu, May 05, 2016
Calculation Description: Title 24 Analysis
Input File Name: McGourty-Mike Mendoza -Jody Jones-15.xml
CF1 R-PRF-01
Page 8 of 12
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
Cooling Component 1:Heating Component 1:Air
Distribution System 1:HVAC Fan 1:1
Other Heating and Cooling
System
Healing Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
Cooling Component 2:Heating Component 2:Air
Distribution System 2:HVAC Fan 2:1
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
Cooling Component 3:Heating Component 3:Air
Distribution System 3:HVAC Fan 3:1
Other Heating and Cooling
System
Heating Component 3
1 Cooling Component 3
HVAC Fan 3
Air Distribution System 3
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
:Heat Pump System 4:::2
Heat Pump Heating and
Cooling System
Heat Pump System 4
Heat Pump System 4
None
None
HVAC - HEATING UNIT TYPES
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 2
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 3
CntrlFurnace - Fuel -Fred central furnace
80 AFUE
HVAC - HEAT PUMPS
01
02
03 04 1 05
06 1 07
08
09
10
Name
Type
Heating
HSPFICOP Cap 47 Cap 17
Cooling
SEER EER
Zonally
Controlled
Multispeed
Compressor
HERS
Verification
Heat PumpSystem 4
Y
DuctlessHeatPum P
10
27000 15600
18
13
No
No
Heat Pump System
4-hers-cool
Registration Number: 216-N0169435A-000000000-0000 Registration Date/Time: 2016-05-0516:58:20 HERS Provider: CalCERTS inc
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF113-04072016-744 Report Generated at: 2016-05-05 16:47:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McGourty Residence Calculation DatelTime: 16:46, Thu, May 05, 2016
Calculation Description: Title 24 Analysis
Input File Name: McGourty-Mike Mendoza -Jody Jones-15.xmi
CF1 R-PRF-01
Page 9 of 12
HVAC - COOLING UNIT TYPES
01
02
03 04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
13A
16.5
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Cooling Component 2
SplitAirCond
13
16.5
Not Zonal
Single Speed
Cooling Component
2-hers-cool
Cooling Component 3
SplitAirCond
13.1
16.5
Not Zonal
Single Speed
Cooling Component
3-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Cooling Component 2-hers-cool
Required
350
Required
Required
Required
Cooling Component 3-hers-cool
Required
350
Required
Required
Required
Heat Pump System 4-hers-cool
Not Required
Not Required
Not Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06 1
07
Name
Type
Duct Leakage
Insulation R-valuo
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
B
Attic
None
Air Distribution System
1-hers-dist
Air Distribution System 2
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
2-hers-dist
Air Distribution System 3
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
3-hers-dist
no ducts
None
Registration Number: 216-N0169435A-000000000-0000 Registration Date/Time: 2016-05-0516:58:20 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFSR-04072016-744 Report Generated at: 2016-05-05 16:47:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McGourty Residence Calculation Daterrime: 16:46, Thu, May 05, 2016
Calculation Description: Title 24 Analysis
Input File Name: McGourty-Mike Mendoza -Jody Jones-15.xml
CF1 R-PRF-01
Page 10 of 12
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handier
Air Distribution System 1-hers-disc
Required
6.0
Not Required
Not Required
Not Required
Not Required
--
Air Distribution System 2-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
�-
Air Distribution System 3-hers-dist
Required
6.0
Not Required
I Not Required
Not Required
Not Required
---
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
058
HVAC Fan 2-hers-fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.58
HVAC Fan 3-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
HVAC Fan 2-hers-fan
Required
0.58
HVAC Fan 3-hers-fan
Required
058
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
91.88
0.25
Default
0
Required
Registration Number: 216-NO16943SA-000000000-0000 Registration Date/Time: 2016-05-0516:58:20 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-05 16:47:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McGourty Residence Calculation Daterrime: 16:46, Thu, May 05, 2016
Calculation Description: Title 24 Analysis
Input File Name: McGourty-Mike Mendoza -Jody Jones-15.xmi
CF1 R-PRF-01
Page 11 of 12
COOLING VENTILATION
01
02
03
04
05
Name
Cooling Vent CFM
Cooling Vent Watts1CFM
Total Watts
Number of Fans
WH Fan 1
61
0.52459
32
1
WH Fan 2
61
0.52459
32
1
WH Fan 3
61
0.52459
32
1
� CaICERTS, Ins.
Registration Number: 216-No169435A-000000000-0000 Registration Date/Time: 2016-05-0516:58:20 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-05 16:47:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: McGourty Residence Calculation DatefTime: 16:46, Thu, May 05, 2016 Page 12 of 12
Calculation Description: Title 24 Analysis Input File Name: McGourty-Mike Mendoza -Jody Jones-15.xm1
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2016-05-05 16:58:20
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application
Responsible Designer Name:
Responsible Designer Signature:
TACO
Tim Scott
Company:
Date Signed:
Scott Design and Title 24, Inc.
2016-05-05 16:58:20
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 216-NO16943SA-000000000-0000 Registration Date/rime: 2016-05-05 16:58:20 HERS Provider: CaICERTS Inc,
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-05 16:47:34