12-1006 (RER) Revision 29 I BUILDING ENERGY ANALYSIS REPORT PROJECT: Ley Residence 47-295 Via Ravenna La Quinta, CA Project Designer: 0 Report Prepared by: Joan D. Hacker Insu-form, Inc. 77810 Las Montanas Road, Suite 201 Palm Desert, Ca 92211 760-345-1352 CITY ORCI-QUINTA BUILDING & SAFETY DEPT. APPROVED 1 FOR CONSTRUCTION DATE n!E% BY_*&-- Job Number: Date: 6/10/2013 3X, JUL 0 5 2013 CITE( of LA QUANTA COMMUNITY DEVELOPMENT i�vww••t 2. The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 11 HVAC System Heating and Cooling Loads Summary 14 EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 2655 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Ley Residence Building Type ® Single Family ❑ Addition Alone I ❑ Multi Family ® Existing+ Addition/Alteration Date 6/10/2013 Project Address 47-295 Via Ravenna La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,835 Addition 0 If of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes E) No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Wall Wood Framed R-11 1,370 Existing Door Opaque Door None 40 Existing Roof Wood Framed Attic R-19 2, 835 Existing Slab Unheated Slab -on -Grade None Z 835 Perim = 75' Existing FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidef ins Shades Status Front (NE) 26.6 0.500 0.38 6.0 none Bug Screen Altered Front (NE) 64.0 0.500 0.38 2.0 none Bug Screen Altered Left (SE) 25.0 1.190 0.83 2.0 none Bug Screen Removed Left (SE) 51.3 0.500 0.38 2.0 none Bug Screen Altered Left (SE) 72.0 0.500 0.38 2.0 none Bug Screen New Rear (SW) 55.0 1.190 0.83 2.0 none Bug Screen Removed Rear (SW) 99.8 0.500 0.38 2.0 none Bug Screen Altered Rear (SW) 64.0 0.500 0.38 6.0 none Bug Screen Altered Rear (SW) 120.0 0.500 0.38 2.0 none Bug Screen New Right (NKK 172.0 0.500 0.38 2.0 none Bug Screen Altered Right (NM 64.0 0.500 0.38 2.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 78•/6 AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Ener Pro 5. 1 by EnergySoft User Number. 2655 RunCode: 2013-06-10715:11:43 ID: Page 3 of 14 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Ley Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 6/10/2013 Project Address 47-295 Via Ravenna La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,835 Addition 0 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidef ins Shades Status Left (S) 8.0 1.190 0.83 2.0 none Bug Screen Removed Left (S) 32.0 0.500 0.38 2.0 none Bug Screen Altered Rear (lM 27.5 1.190 0.83 2.0 none Bug Screen Removed Rear (M 24.0 0.500 0.38 2.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2013-06-10T15:11:43 /D: Page 4 of 14 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Ley Residence Building Type ® Single Family 0 Addition Alone 1 0 Multi Family ® Existing+ Addition/Alteration Date 6/10/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 1, 835.0 ft' Covered Slab Floor, 3.500" thick at Existing Living HIGH MASS Design - Verify Thermal Mass: 1,000.0 ft' Exposed Slab Floor, 3.500" thick at Existing Living HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnemyPro 5.1 by EnerqySoft User Number: 2655 RunCode: 2013-06.10T15:11:43 ID: Page 5 of 14 PERFORMANCE CERTIFICATE: Residential Part 3 of 5) CF-1 R Project Name Building Type m Single Family 0 Addition Alone Date Ley Residence 0 Multi Family m Existing+ Addition/Alteration 6/10/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 Space Heating 8.17 7.33 0.84 Space Cooling 121.11 121.85 -0.74 Fans 26.26 26.31 -0.05 Domestic Hot Water 14.41 14.41 0.00 Pumps 0.00 0.00 0.00 Totals 169.94 169.90 0.04 Percent Better Than Standard: 0.0% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 45 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NE) 420 91 Fuel Available at Site: Natural Gas (SE) 520 155 Raised Floor Area: 0 (SK) 700 308 Slab on Grade Area: 2.835 (N►9 560 236 Average Ceiling Height: 9.0 Roof 2,835 0 Fenestration Average U-Factor: 0.50 TOTAL: 790 Average SHGC: 0.38 Fenestration/CFA Ratio: 27.9% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company /nsu-form, Inc. 6/102013 Address 77810 Las Montanas Road, Suite 201 Name Joan D. Hacker 2Le=44% +innedD City/State/ZipCity/State[Zip Palm Desert, Ca 92211 Phone 760-345-1352 Date The individual with overall design responsibility hereby certifies that the proposed uilding design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Address Name City/State/Zip . Phone Signed License # Date EnemvPro 5.1 by EnemySoft User Number. 2655 RunCode: 2013-06-10T15:11:43 ID: Page 6 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Ley Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1611012013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 289 0.110 R-11 45 90 Existing 4.3.1-A2 Existing Living Door 40 1.450 None 45 90 Existing 4.5.1-A1 Existing Living Wall 297 0.110 R-11 135 90 Existing 4.3.1-A2 Existing Living Wall 216 0.110 R-11 225 90 Existing 4.3.1-A2 Existing Living Wall 324 0.110 R-11 315 90 Existing 4.3.1-A2 Existing Living Roof 2,835 0.049 R-19 45 0 Existing 4.2.1-A4 Existing Living Slab 1,835 0.730 None 0 180 Existing 4.4.7-A1 Existing Living Wall 68 0.110 R-11 180 90 Existing 4.3.1-A2 Existing Living Wall 176 0.110 R-11 270 90 Existing 4.3.1-A2 Existing Living Wall 400 0.110 R-11 135 90 Removec 4.3.1-A2 Existing Living Slab 1,0001 0.730 None 0 180 Existing 4.4.7-A1 Existing Living FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 26.6 0.500 NFRC 0.38 NFRC 45 Altered 1WC 6200 Alum2ow--E Existing Living 2 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 3 Window 64.0 0.500 NFRC 0.38 NFRC 45 Altered IWC 6200 Alum/Low-E Existing Living 4 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 5 Window 25.0 1.190 Default 0.83 Default 135 Removed Single Metal Clear Existing Living 6 Window 1 45.0 0.500 NFRC 0.38 NFRC 135 Altered IWC 6200 Alum/Low-E Existing Living 7 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 8 Window 2.7 0.500 NFRC 0.38 NFRC 135 Altered IWC 6200 Alu lLow-E Existing Living 9 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 10 Window 3.6 0.500 NFRC 0.38 NFRC 135 Altered IWC 6200 Alumkow-E Existing Living 11 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 12 Window 72.0 0.500 NFRC 0.38 NFRC 135 New IWC 6200 AluMLow-E Existing Living 13 Window 40.0 1.190 Default 0.83 Default 225 Removed Single Metal Clear Existing Living 14 Window 15.0 1.190 Default 0.83 Default 225 Removed Single Metal Clear Existing Living 15 Window 35.8 0.500 NFRC 0.38 NFRC 225 Altered IWC 6200 A/um/Low-E Existing Living 16 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t I Wd Ove hang Left Fin Len H t LExt REA Dist Len Right Fin Hclt Dist Len H t 1 Bug Screen 0.76 8.0 3.4 6.0 0.1 6.0 6.0 2 Bug Screen 0.76 8.0 3.4 6.0 0.1 6.0 6.0 3 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 6 Screen 0.76 6.8 2.3 2.0 0.1 2.0 2.0 7 _Bug Bug Screen 0.76 6.8 2.3 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 2.0 1.4 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 2.0 1.4 2.0 0.1 2.0 20 10 Bug Screen 0.76 2.0 5.3 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 2.0 5.3 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 8.0 9.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 15 18ug Screen 1 0.76 5.5 6.5 2.0 0.1 2.0 2.0 16 Bug Screen 1 0.76 5.5 6.5 2.0 0.1 2.0 2.0 Ener Pro 5.1 by EnergySoft User Number. 2655 RunCode: 2013-06-10Ti5:11:43 ID: Page 7 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Ley Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family 9 Existing+ Addition/Alteration Date 1611012013 OPAQUE SURFACE DETAILS Surface U- T e Area Factor Insulation Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 17 Window 64.0 0.500 NFRC 0.38 NFRC 225 Altered IWC 6200 Alum/Low--E Existing Living 18 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 19 Window 64.0 0.500 NFRC 0.38 NFRC 225 Altered 1WC 6200 Alum/Low--E Existing Living 20 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 21 Window 120.0 0.500 NFRC 0.38 NFRC 225 New I IWC 6200 Alum/Low-E Existing Living 22 Window 40.0 0.500 NFRC 0.38 NFRC 315 Altered IWC 6200 Alum/Low-E Existing Living 23 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 24 Window 14.0 0.500 NFRC 0.38 NFRC 315 Altered IWC 6200 Alum/Low-E Existing Living 25 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 26 Window 54.0 0.500 NFRC 0.38 NFRC 315 Altered IWC 6200 Alumkow-E Existing Living 27 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 28 Window 64.0 0.500 NFRC 0.38 NFRC 315 Altered IWC 6200 Alum/Low-E Existing Living 29 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 30 Window 64.0 0.500 NFRC 0.38 NFRC 315 New IWC 6200 Alumkow-E Existing Living 31 Window 8.0 1.190 Default 0.83 Default 180 Removed Single Metal Clear Existing Living 32 JMndow 32.01 0.500 NFRC 0.38 1 NFRC 180 Altered IWC 6200 Alum/Low-E Existing Living (1) LI -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-6 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat I Wd Ove hang Left Fin Len H t LExt I REA Dist Len Right Fin Hat Dist Len H t 17 Bug Screen 0.76 8.01 8.0 2.0 0.1 2.01 2.0 18 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 8.0 8.0 6.0 0.1 6.0 6.0 20 Bug Screen 0.76 8.0 8.0 6.0 0.1 6.0 6.0 21 Bug Screen 0.76 8.0 15.01 2.01 0.1 2.0 2.0 22 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 23 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 24 Bug Screen 0.76 3.5 4.0 2.0 0.1 2.0 2.0 25 Bug Screen 0.76 3.5 4.0 2.0 0.1 2.0 2.0 26 Bug Screen 0.76 8.0 2.5 2.0 0.1 2.0 2.0 27 Bug Screen 0.76 8.0 2.5 2.0 0.1 2.0 2.0 28 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 29 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 30 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 31 JBug Screen 0.76 8.0 1.0 2.0 0.1 2.0 2.0 32 JBug Screen 0.76 8.0 4.0 2.0 0.1 2.0 2.0 Ener Pro 5.1 by EnerqySoft User Number., 2655 RunCode: 2013-06-1 0 71 5:11:43 ID: Pae 8 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Ley Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family Ea Existing+ Addition/Alteration I I ii Date 6/10/2013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix T e Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID TvDe Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 34 Window 8.0 1.190 Default 0.83 Default 270 Removed Single Metal Clear Existing Living 35 Window 19.5 1.190 Default 0.83 Default 270 Removed Single Metal Clear Existing Living 36 Window 24.0 0.500 NFRC 0.38 NFRC 270 New IWC 6200 Alurnkow-E Existing Living (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t Wd Ove hanq Left Fin Right Fin Len H qA LExt REA Dist Len I Hot Dist I Len H t 33 Bug Screen 0.76 8.0 4.0 2.0 0.1 2.0 2.0 34 Bug Screen 0.76 8.0 1.0 2.0 0.1 2.0 2.0 35 Bug Screen 0.76 6.5 3.0 2.0 0.1 2.0 2.0 36 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 Ener Pro 5.1 by EnergySoft User Number: 2655 RunCode: 201346-10T15:11:43 ID: Pa e 9 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Ley Residence Building Type la Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 6/10/2013 BUILDING ZONE INFORMATION System Name Zone Name New Floor Area Existinq Altered Removed Volume Year Built Living Zone Existina Livino 2,835 25,515 1960 Totals 01 2,8351 01 0 HVAC SYSTEMS System Name Ot . Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Living Zone 2 Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Cooling Duct Ducts Duct Location R -Value Tested? Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing 13 11 13 WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.53 n/a n1a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft C o m — System Name Pipe Len th Pipe Diameter Insul. Thick. Ot . HP Plenum Outside Buried ❑ EnergyPro 5.1 by Ener Soft User Number.' 2655 RunCode: 2013-06-10T15:11:43 ID: Pae 10 of 14 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Ley Residence Date 6/10/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed desi n labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150 : Air retarding wrap is tested, labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 permAnch and shall be protected from physical damage and UV light deterioration. Fire laces Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight-fifting tight-fittingdamper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 1500)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §1506)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoff User Number. 2655 RunCode: 2013-06-10T15:11:43 ID: Page 11 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Ley Residence 1 6/10/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A. or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode. 2013-06-10T15:11:43 ID: Page 12 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Ley Residence 1611012013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l 5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131 134, and 146. §150(k)l 6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-06.10715:11:43 ID: Page 13 of 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Ley Residence Date 6/10/2013 System Name Living Zone Floor Area 2,835 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 2,340 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 71,000 47,321 2,803 947 42,902 Total Output Btuh 142,000 0 Output Btuh/ ft 50.1 4,013 3,048 Cooling System 0 0 Output per System 58,000 0 0 0 0 Total Output Btuh 116,000 0 2,803 0 Total Output ons 9.7 4,013 3,048 Total Output Stuh/s ft 40.9 Total Output s ftfTon 293.3 55,346 F 48,998 Air System CFM per System 1,500 HVAC EQUIPMENT SELECTION Airtlow cfm 3,000 Exist 68,685 33,466 142,000 Airflow cfm/s 1.06 Airflow cfm/ron 310.3 Outside Air 0/6 0.0% Total Adjusted System Output 68,685 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 33,466 Aug 3 PM 142,000 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF O; Outside Air 0 cfm Supply Fan 3,000 cfm 69 OF 69 OF 114 OF T Y Heating Coil 113 OF ' ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 79/64°F 79/64°F 58/57°F Outside Air Ar 0 cfm Supply Fan Cooling Coil 59 / 57 OF 3,000 cfm i 46.9 % ROOM 79/64°F 78/64°F t EnergyPro 5.1 by EnergySoft User Number.' 2655 RunCode: 2013-06-10T15:11:43 /D: Page 14 of 14