Loading...
07-3057 (SFD) Revision 1CITY OF LA QUINTA PLAN CHECK CORRECTION LIST July 30, 2008 PLAN CHECK NO.: 08-980 (Revision) SECOND CHECK/ APPROVED ADDRESS: 53-461 Via Pisa OCCUPANCY: R -3/U SCOPE OF WORK: Deepen Footing TYPE -OF -CONST.: V -B ADDITIONAL PLAN CHECK FEE: 4 Hours total The submitted plans and specifications have been reviewed by the VCA CODE GROUP. In our professional opinion the plans are in substantial conformance with the building codes and regulations adopted by the CITY OF LA QUINTA and the State of California Amendment. APPROVAL FOR A BUILDING PERMIT IS HEREBY RECOMMENDED SUBJECT TO OBTAINING APPROVALS/CLEARANCES FROM ALL APPLICABLE CITY DEPARTMENTS, AGENCIES, AND ASSOCIATIONS. Plans checked by: Lam Nguyen, P.E. VCA CODE GROUP 2200 W Orangewood Ave, Ste 155 Orange, CA 92868 (714) 363-4700 ext. VCA File No. LQ -20521R 1 5�(� Title: SCHMALZRIED RES. Job # 1196 Dsgnr: DEL MAR ENGINEERIN( Date: 8:38AM, 15 MAY 08 Description: FOOTING t Scope Rev: 560000 Page 1 User: KW-0606115,Ver 5.8.0,1 -Dec -2003 Combined Footing Design (c)1983-2003 ENERCALC Engineering Software cant columns at nook.ecw.Calculations Description FOOTING AT STEEL COLUMNS (SW #15) 1ST FLR, NOOK General Information Factoring of entered loads to ultimate loads within this program is according Code Ref: ACI 318-02,1997 UBC, 2003 IBC, 2003 NFPA 5000 Allow Soil Bearing 2,500.0 psf fc 2,500.0 psi Seismic Zone 4 Fy 60,000.0 psi Concrete Wt 145.0 pcf Min As Pct 0.0000 Short Term Increase 1.33 Distance to CL of Rebar 3.50 in Overburden 0.00 psf Live & Short Term Load Combined Dimensions Factoring of entered loads to ultimate loads within this program is according 111111 1 Footing Size... MEN Column Support Pedestal Sizes Distance Left 0.50 ft #1 : Square Dimension 0.00 in Dist. Betwn Cols 11.50 ft ...Height 0.00 in Distance Right 3.00 ft #2 : Square Dimension 0.00 in Footing Length 15.00 ft ...Height 0.00 in Width 2.75 ft Applied Moments... Dead Load k -ft Thickness 36.00 in O 987 ^" .....................__.__. Load factoring supports 2003 IBC and 2003 NFPA 5000 by virtue of their references to ACI 318-02 for concrete design. Factoring of entered loads to ultimate loads within this program is according to ACI 318-02 C.2 Steel Req'd @ Left Vertical Loads... (a) Left Column 0) Ri-ght Column Dead Load k k QROFESS/py Live Load k k k � ShortTerm Load Min. Overturning Stability �MQZ Soil Pressures Applied Moments... Dead Load k -ft k- C� W N O 987 ^" Eccentricity Live Load Short Term Load k -ft 41.000 k -ft k- 41.000 k- EXP. 12/31/ 0.000 ft Applied Shears... 0.0 3,325.0 psf Zv t �� Dead Load k k CIVIL' Live Load 4.500 k OFCALIF� Short Term Load 4.500 k Dead + Live Summary Warning: OTM Ratio < 1.5 Length = 15.00ft, Width = 2.75ft, Thickness = 36.00in, Dist. Left = 0.50ft, Btw.n. = 11.50ft, Dist. Right = 3.00ft Maximum Soil Pressure 3,051.64 psf Allowable 3,325.00 psf Steel Req'd @ Left 0.043 m2/ft Max Shear Stress 2.63 psi Steel Req'd @ Center 0.222 int/ft Allowable 85.00 psi Steel Req'd @ Right 0.109 in2/ft Min. Overturning Stability 1.235:1 Soil Pressures Soil Pressure @ Left Actual Allowable ACI Factored Eccentricity Dead + Live 435.0 2,500.0 psf Eq. C-1 609.0 psf 0.000 ft Dead+Live+Short Term 0.0 3,325.0 psf Eq. C-2 -0.0_ psf _ 6.075 ft Eq. C-3 0.0 psf Soil Pressure @ Right End Dead + Live 435.0 2,500.0 psf Eq. C-1 609.0 psf 0.000 ft Dead+Live+Short Term 3,051.6 3,325.0 psf Eq. C-2 4,272.3 psf 6.075 ft Stability Ratio 1.2 :1 Eq. C-3 2,746.5 psf �1 Title: SCHMALZRIED RES. L15 QB-( Dsgnr: DEL MAR ENGINEERIN( Date: 8:38AM,Description: FOOTING f Scope Rev: 580000 Page 2 User: KW -0606115, Ver 5.8.0, 1 -Dec -2003 Combined Footing Design (c)1983-2003 ENERCALC Engineering Software cant columns at_nook.ecw:Calculations Description FOOTING AT STEEL COLUMNS (SW #15) 1ST FLR, NOOK Moment & Shear Summary ( values for moment are given per unit width of footing) Moments... ACI C-1 ACI C-2 ACI C-3 Mu @ Col #1 0.00 k-ft/ft -0.08 k-ft/ft -0.05 k-ft/ft Mu Btwn Cols 0.00 k-ft/ft 24.30 k-ft/ft 24.26 k-ft/ft Mu @ Cot #2 0.00 k-ft/ft 11.99 k-ft/ft 7.71 k-ft/ft One Way Shears... Vn : Allow* 0.85 85.000 psi 85.000 psi 85.000 psi Vu @ Col #1 0.000 psi 0.000 psi 0.000 psi Vu Btwn Cols 0.000 psi 0.000 psi 0.000 psi Vu @ Cot #2 0.000 psi 2.631 psi 1.691 psi Two Way Shears... Vn : Allow* 0.85 170.000 psi 170.000 psi 170.000 psi Vu @ Col #1 0.000 psi 1.057 psi 0.680 psi Vu @ Col #2 0.000 psi 1.477 psi 0.949 psi Reinforcing ( values given per unit width of footing) Left Edge of Col #1 Between Columns (M Right Edge of Col #2 Ru/Phi As Req'd Ru/Phi As Req'd Ru/Phi As Req'd ACI C-1 0.00 psi -0.043 in2/ft @ Top 0.00 psi -0.043 in2/ft @ Top 0.00 psi -0.043 in2/ft @ Top ACI C-2 0.08 psi -0.043 in2/ft @ Top 25.57 psi 0.222 in2/ft @ Bottom 12.61 psi 0.109 in2/ft @ Bottom ACI C-3 0.05 psi -0.043 in2/11 @ Top 25.52 psi 0.222 in2/ft @ Bottom 8.11 psi 0.070 in2/ft @ Bottom ACI Factors (per ACI, applied internally to entered loads) ACI C-1 & C-2 DL 1.400 ACI C-2 Group Factor 0.750 Additional Seismic "1.4" Factc 1.400 ACI C-1 & C-2 LL 1.700 ACI C-3 Dead Load Factor 0.900 Additional Seismic "0.9" Facto 0.900 ACI C-1 & C-2 ST 1.700 ACI C-3 Short Term Factor 1.300 ....seismic = ST * : 1.100 . �.. oQRp ml Z R N . C Q 867 EXP. 121311® J'> CIV11. �T�OF CAI�F�