Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-1475 (SFD)
Building X441 Address 6.35- 114 l�vUA. Tittfl `\X P.O. BOX 1504 APO LI CATION ONLY 78-495 CALLE TAMPICO Q LA QUINTA, CALIFORNIA 92253 A&c, Tel. I' t/9i- -977 . OW5"j'd—DFS�'RT �F��icGPI�GN'r CC2P, k -v3 6s "W L city L►�QK t),7! 115 - State Lic. & Classif. L{'L Arch., Engr., Designer Z&y/te Address BUILDING: TYPE CONST.11'0 P. CCC. GR A.P. Number Y72 ' 97 G —491 �s q Legal Description Ao% S/ lue r 2_5 / -fl Project Description ./ AP, W7h�cYan- 1 n I G, Zip j T76o City Sq. Ft. Lic. # Size [New ❑ !3-/53 MMzI �p IJQfv,r 174n. P, 26--/a05o Zip State vv� 2211 Lic. # 4J�7�9Sr3 LICENSED CONTRACTOR'S DECLARATION OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant [o the provisions o1 the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 0/the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code.. The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT., If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT tic .s< - a_ �JSQ/No. Stories .2 No. Dw. Sto 7 `�o ries Units Add ❑ Alter ❑ Repair ❑ Demolition ❑ Valuation PERMIT Plan Chk. Dep. Plan Chk. Bal. Cjo o 2- P(_)_0 P(_)_0 I n I D 4 Issued by: Validated by:_ Validation: YELLOW = APPLICANT Date PINK = FINANCE AMOUNT rM Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 Project Name: Brian Sonnenberg This Box For District Use Only DEVELOPER FEES PAID AREA: -MOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: RECEEPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Date: July 29, 2005 Owner's Name: Brian Sonnenberg Phone No. (760) 567-2026 Project Address: 52-635 Via Dona, La Quinta, CA 92253 Project Description: 1 Single Family Home APN: 772-410-999-29894-4 Tract #: Lot #'s: Type of Development: Residential XX Commercial Industrial Total Square Feet of Building Area: 4,596 Sq. Ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: 07/29//05 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 4596 Amount per Sq.Ft. $ 2.88 Amount Collected $ 13,236.48 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: Leticia C. Torres, Facilities Clerk NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that is strict provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment cf the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as terein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as deUrmined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. 41V:cim}'dnc�-dcvfcis:'cirtiticaii+ofc4)mpliincc form tables'[')USF-doc 1/16/03 T 05/31/05 14:20 FAX 503 227 4634 FJDELITY NATIONAL TITLE COMPANY _ SUBDMSION DEPARTMENT WHEN RECORDED MAIL TO: Mr. Sonnenberg 23432 Stafford Hili Ct . West Linn, OR 97068 MAIL TAX STATEMENT TO: SAME AS ABOVE PORTLAND BOLT & MFG. CO. DOCUMENT TRANSFER TAX $ 605.00 XX Computed on the consideration or value of property conveyed; OR x001/005 DOC Cs®@'4-028eiaS3 84/20/2004 We" Fee�30.60 Page i of 6 010 T Tax Paid Recorded in Of-tvial Records Cou"4Y Of Riverside Gary Assessor, county Orao tY C 111! Itrk 8 Recorder !l 111111 Bl �!f II 1111 !I!! !� N!l1111 llll111l11111 Computed on the consideration or value less liens or encumbrances remaining at the time of sale. \�M - u - Signature of Declarant or Agent determining tax — Firm Name 7 ~ D dv GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company ("Grantot" ), hereby (3RANT(S) to Sonnenberg Family, a Oregon limited liability ii:ompaixy ("Grantee"), the real property located in the City of La Quinta, County of Riverside, State of California, described as: See Legal Description attached hereto and incorporated herein as Exhibit "A". SUBJECT TO all matters of record including, without limitation, the covenants and agreements described in Exhibit "A" attached hereto. Dated: ND LA QUMI A PARTNERS, LLC, a Delaware limited liability company By: Nationwide Realty Investors, Ltd. an Ohio limited H ility corn y its managing ber By: Joseph . Arenson Authorized Representative DA °COR NOCM W M2C Ea NCHC ! EtN. I 1 1 COPY LONG 0.CrUN0 Computed on the consideration or value less liens or encumbrances remaining at the time of sale. \�M - u - Signature of Declarant or Agent determining tax — Firm Name 7 ~ D dv GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company ("Grantot" ), hereby (3RANT(S) to Sonnenberg Family, a Oregon limited liability ii:ompaixy ("Grantee"), the real property located in the City of La Quinta, County of Riverside, State of California, described as: See Legal Description attached hereto and incorporated herein as Exhibit "A". SUBJECT TO all matters of record including, without limitation, the covenants and agreements described in Exhibit "A" attached hereto. Dated: ND LA QUMI A PARTNERS, LLC, a Delaware limited liability company By: Nationwide Realty Investors, Ltd. an Ohio limited H ility corn y its managing ber By: Joseph . Arenson Authorized Representative 405i31�05 14:21 FAX 303 227 4634 PORTLAND BOLT & MFG. CO. 2002/005 STATE OF California COUNTY OF _ Riverside On Match 8, 2004 before me, . Larby, Notary P bli (Name, Title of Officer) personally appeared Joseph 4, Ar nson personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) islare subscribed to the within Instrument and acknowledged to me that he/shelthey executed the some in his/her/their authorized capecity(iss), and that by his/her/their signature(s) on the Instrument the person(s), or the entity upon behalf of which the persona) acted, executed the instrument. . WITNESS my hand and official seal. (Signal ra of No y ubliC) OFFICIAL' 5 K. LAr-2y SO PM *1.269797 MottRIVERSIDECOUrNTy MYIUF24,UPL'ec 2004 +,This area for notarial seal) ,05!31/05 14:21 FAX 503 227 4034 PORTLAND BOLT & MFG. CO. EXUDIT "A" Legal Description Parcel No. 1; 1a003/005 Lot 81 (the "Lot') of Tract No. 29894-4, in the City of La Quinta, as shown by Map on file in Book 351, Pages 49 to 57, inclusive, of Maps, in the Office of the County Recordes of Riverside County, California. EXCEPTING AND RESERVING THEREFROM TO GRANTOR, and its successors, assigns, invitees, licensees and employees, together with the right to grant and transfer all or a portion of the same, all easements and rights for access, ingress, egress, encroachrnent, maintenance, drainage, support, and for other purposes over the Association Maintenance Areas and other portion of the Lot, reserved to Grantor in the following instruments: 1. The Amended and Restated Declaration of Covenants, Conditions a.1d Restrictions and Reservation of Easements for The hideaway Owners Association (as amended or supplemented, the "Declaration"), recorded on December 13, 2002, as Instrument No. 2002- 745938, of Official Records of Riverside County, California (the "Official Reaordb"); 2, The Supplementary Declaration of Annexation of property, recorded on March 4, 2004, as Instrument No. 200¢0151981, of Official Records of Riverside Country, California. FURTHER RESERVING THEREFROM, the right to enter the Lot for a term of twelve (12) months following the recordation of this Grant Deed, to complete and -epair any improvements or landscaping located thereon as determined necessary by Grantor, in its sole discretion, in order to comply with requirements for the recordation of the Final Tract. Map, the grading of said Tract and/or in compliance with the requirements of applicable govermnental agencies. Such entry by Grantor shall be preceded by reasonable notice to Grantee before such entry. If this reservation of right of entry is not complied with by Grantee, Grantor may enforce this right of entry in a court of law. Grantee shall be responsible for all damages arising out of said breach including attorneys' fees and court costs. This reservation of right of entry shall automatically expire twelve (12) months from the recordation of this Grant Deed. Parcel No. 2: Nonexclusive casements for access, ingress, egress, drainage, maintenances repairs and for other purposes, all as described in the Declaration. SUBJECT TO: Non delinquent general, special and supplemental real property taxes and assessments. u5.�J1 u5 14:2z FAS 503 227 4634 PORTLAUND BOLT & MFG. CO, 1 004/005 2. All other covenants, conditions, restrictions, reservations, easements, rights and rights-of-way of record including, without imitation, the Declaration and the Map for Tract No. 29894-4. Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed, (b) grants to Grantor and The Hideaway Owners Association such powers and rights as are set forth in the Declaration, and (c) accepts, - covenants and agrees to be bound by and assume performance of ail of the applicable provisions and requirements set forth in the Declaration, including Section 13,15 establishing the procedure for resolving disputes with Grantor, and the notice, which provisions and requircm�.nts are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be performed by Grantee under the Declaration. The restrictions on use and occupancy of the Lot a: a set forth in the Declaration to which this Grant Deed is specifically and expressly made subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING, ,;ranting unto Grantor and The Hideaway Owners isociation such powers and rights which are set forth in the Declaration defined above, on 1 / _, 2004. SONNENBER9 FAMTLY, LLC Brian Sonnenberg, STATE OF ) 65. COUNTY OF t��//J� �_ ) On /4p^ 0 1 I's— , 2001, before me, the undersigned, a notary public in and for said State, personally appeared Brian Sonnenberg, (or proved tome on the basis of satisfactory evidence) to be the persorV whose namel** /S 4 subscribed to the within instrument d acknowledged to me that Wt the same in 44 authorized capacitio, and that by ti r signature on the instrument the person/ or the entity upon behalf of which the perso4acted, executed the instrument. WITNESS MY HAND AND OFFICIAL SEAL. (SEAL] Signature My commission expires: M,, a;�, ?.0j-7 05/91/05 14:22 FAX 503 227 4894 PORTLAND BOLT & MFG. CO. C;ovemmejlt Code 27361.7 I certify under penalty of yei jury that the notary seal an the ciocutllel)t,to which this statement is attached reads as follows: Name of notaty: Commission No.: Date Commission expires: County: 13y: Date: 1005/005 HIDEAWAY OWNERS ASSOCIATION April 20, 2005 Mr. Jeffrey Miller 834 SW St. Clair Avenue. Suite 202 Portland, OR 97.205-1322 RE: Sonnenberg/Final Working Drawings -Landscape Lot 81D at 52635 Via Dona Dear Mr. Miller, The Hideaway Design Review. Committee has rev_ewed and approve the Final Working Drawings for Lot 81D. Please have your General Contractor call to schedule a Pre - Construction Meeting prior to the commencement of construction at, the lot per the Design Guidelines. Please call Brook Marshall at (760) 346-1161 with any questions. Sincerely, Hideaway Design Review Committee - cc: DRC File DESERT RESORT MANAGEMENT POST OFFICE BOX 4772 / PALM DESERT, CALIFORNIA 94261-4772 73-350 ALESSANDRO, SUITE f / PALM DESERT, CALIFORNIA 82260 PHONE 760.346.I161 / FAX 760.346.9918 / E-MAIL: ASSOCIATION@HIDEAWAYGOLFCLUB.COM u -r uo Wt z at Ip KF STRUCTURAL&SANTAMRR I A 760 836 0856 P.1 R F STRUCTURAL CONSULTANTS, INC. 75-153 MERLE, DRIVE, STE. 6, PALM DESERT, CA 92211 �. PHONE (760) 836-1100 FAX (760) 836-0856 ?_e�� 0S -. , ��, E- MAIL RAYMO "C7(�kFSTRlJC7lJRAL.COM MAY 4, 2006 GREGORY JOHNSON CUSTOM HOMES BUILDER 78-365 HIGHWAY 111, SUiTF 177 LA QUINTA, CA. 92253 Attn-_ Mr, GREGORY JOHNSON Re.: THE SONNENBERG RESIDENCE; 52-635 VIA DONNA. LA QUINTA, CA. FOLLOW-UP 7Y7 WALK THROUGH J013 NO.: 4306 DEAR. GREG THIS LF7'1'•ER ADVISUS THAT WE HAVE OBSERVED THE STRUCTURAL. REQUIREMENTS TTIAT ARF. VISIBLE DURING CONS'T'RUCTION AT THE TIME OF OUR SITE VISIT. WE BELIF..VE THAT THE AS-BIJII,T CONSTRUCTION AT THE TIME OF O -1R VISIT IS IN GENERAL CONFORMANCE WITH OUR S'T'RUCTURAL PLANS AND RELEVANT CORRESPONDENCE ISSUED BY OUR OFFICE. WE OBSERVED THF BUILDING IN ITS FRAMED CONDITION PRIOR TO INSTALLATION OF DRYWALL, AND STUCCO. WE OBSERVED THE VISUAL AND AC'CESSIBI.,E STRUCTURAL REQUIREMENTS. (EXCLUSIONS ARE ITEMS SUCH AS: TOOTING SIZE AND REINFORCEMENT, TOP PLATE SPLICES, ROOF SHEATHING, AND ANY STRAPS ABOVE THE ROOF SHEA"T"HING). RESPECTM TL•,E:V Si TnA fmrvn Fkp.0(;-958 30.0 r ~ ' of '�/!i :f•S)�i��\` •� ZEYAD FAQTII, PE Certificate of Occupancy -itOFF 9wBuilding & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 52635 VIA DONA Use classification: SFD Building Permit No.: 05-1475 Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL Owner of Building- MR. SONNENBERG Address: 23432 STAFFORD HILL COURT City, ST, ZIP: WEST LINN ORE 97068 By: S. WILLETT Date: 10-27-06 Building Official POST IN A CONSPICUOUS PLACE R F STRUCTURAL CONSULTANTS, INC. 75-153 MERLE DRIVE, STE. B, PALM DESERT, CA 92211 PHONE (760) 836-1000 FAX (760) 836-0856 E- MAIL R_ .FRANGIE@VERIZON.NET September 30, 2005 Gregory Johnson Custom Home Builder 78-365 highway 111, suite 177. La quinta, Ca. 92253 Tel. (760) 567-2026 Fax (760) 771-5309 Attn.: Mr. Gregory Jonhson Re.: The Sonnenberg Residence r 5235 Via Dona La qumta, Ca Job no.: 4306 Subject: Alternate Grade Beam Dear Gregory In regard of the above mentioned project, and as per our phone conversation on September 24, 2005, we submit the following: As shown per the attached partial foundation plan and grade bean calculations the grade beam may be 12" wide and 24" deep at the breakfast room Hardy Frame shear wall. Verify the above information with the building department prior to construction If you have any questions please do not hesitate to contact our office. Zeyad Faqih P.E. QROFESS��N� M. F l W �� 9pyF2z NO. 5.7958 Exp ng -an CAVIL �P CALIED��� attachment (3) t�rl I CE NTA CITY OF LA � DEPT. ApPRAVED FOO FOR DA'mflmf --BY, A RE -INSPECTION FEE OF $30 WILL BE CHARGED IF THE APPROVED PLANS AND JOB CARD ARE NOT Oh! THE SITE FOR A SCHEDULED INSPECTION. NO EXCEPTIONS! c .N To specify your title block on these five lines, use the SETTINGS main menu selection, choose the Printing & Title Block tab, and ent your title block information. Title : Dsgnr: Description Scope : Job # Date: 9:01AM, 30 SEP 05 User: K%-0 04868, Ver 5.5.0, 25 -Sep -2001 Combined.'Footing DeSI n Page 1 fc11983-2001 ENERCALC Enaineerina Software g Description GRADE BEAM AT HARDY FRAME General Information Calculations are designed to ACI 318-95 and 1997 UBC Requirements - .. sa.- - , .. , �;egsta •n ;:. .. .. _ :.. - _ , .. •rs _. ,.. -. . .. _ s __ aiao:.:x-:.ze:.r�.w:r�.a;yes:r�sw,��.,�.�rr:;a�_ce+..+,s� Allow Soil Bearing 2,500.0 psf rc 2,500.0 psi Seismic Zone 4 Fy 40,000.0 psi Concrete Wt 145.0 pcf Min As Pct 0.0014 Short Term Increase 1.33 Distance to CL of Rebar 3.50 in Overburden 0.00 psf Live & Short Term Load Combined Dimensions Dung Size... 612.92 psf Column Support Pedestal Sizes Allowable Distance Left 10.00 ft #1 : Square Dimension 0.00 in Dist. Betwn Cols 4.00 ft ...Height 0.00 in Distance Right 10.00 It #2: Square Dimension 0.00 in Footing Length 24.00 It ...Height 0.00 in Width 1.00 R Thickness 24.00 in Loads Vertical Loads... (cD Left Column ci) Right Column Dead Load k k Live Load k k Short Term Load 5.500 k k Applied Moments... Dead Load k -ft k41 Live Load k -ft k -g Short Term Load 20.000 k -ft k -R Footing Design OK Length = 24.00ft, Width = 1.00ft, Thickness = 24.00in, Dist. Left = 10.00ft, Btwn. = 4.00ft, Dist. Right = 10.00ft Maximum Soil Pressure 612.92 psf Dead + Live Allowable 3,325.00 psf Steel Req'd @ Lef 0.344 in2fft Max Shear Stres; 13.71 psi Steel Req'd @ Cente 0.893 in2/ft Allowable 85.00 psi Steel Req'd @ Righ 0.455 in2/ft Min. Overturning Stabilit 8.026:1 476.8 ps` Soil Pressures Soil Pressure @ Left Actual Dead + Live 290.0 Dead+Live+Short Term 425.4 Soil Pressure @ Right End 0.000 ft Dead + Live 290.0 Dead+Live+Short Term 612.9 Stability Ratio 8.0 :1 Nab►e ACI Factored Eccentricity 2,500.0 psf Eq. 9-1 406.0 ps-' 0.000 ft 3,325.0 psf Eq. 9-2 595.6 ps= 0.722 ft Eq. 9-3 476.8 ps` 2,500.0 psf Eq. 9-1 406.0 ps� 0.000 ft 3,325.0 psf Eq. 9-2 858.1 ps' 0.722 ft Eq. 9-3 686.9 ps-' To specify your title block on these five lines, use the SETTINGS main menu selection, choose the Printing & Title Block tab, and ent your title block information. Title: Dsgnr: Description Scope : Job # Date: 9:01AM, 30 SEP 05 Rev: 550100 User: KW-WO4868, Ver 5.5.0, 25 -Sep -2001 Combined Footing Design Page 2 (01983-2001 ENERCALC Engineering Software Description GRADE BEAM AT HARDY FRAME values for moment are i +en per unit width of footm Moment &Shear Summary ( g` p � � � g) IT Moments... ACI.9-1 ACI 9-2 ACI 9-3 Mu @ Col #1 0.00 k-ft/ft 11.30 k-ft/ft 12.25 k-ft/ft Mu Btwn Cols 0.00 k-ft/ft 39.30 k-ft/ft 40.25 k-ft/ft Mu @ Col #2 0.00 k-ft/ft 20.78 k-ftfft 19.84 k-ft/ft One Way Shears... Vn : Allow' 0.85 85.000 psi 85.000 psi 85.000 psi Vu @ Col #1 0.000 psi 7.918 psi 8.496 psi Vu Btwn Cols 0.000 psi 0.000 psi 0.000 psi Vu @ Col #2 0.000 psi 13.710 psi 13.132 psi Two Way Shears... Vn : Allow • 0.85 170.000 psi 170.000 psi 170.000 psi Vu @ Col #1 0.000 psi 4.062 psi 4.055 psi Vu @ Col #2 0.000 psi 0.674 psi 0.650 psi Reinforcing ( values given per unit width of footing) ?4SYi25Kde31YL::Jiie4lAf:!Ul'�.- ..o��.v y .4. ••. .. . s; F :sAi.�alaa"_.:�t3iCitr'S2i"N '�'/ w' '..�C-�tai:'asteYYl+oriuifvw5•)(9J�3ii::;r 'r - diSUO.LL"":C1.3vri)cC+=� @ Left Edge of Col 91 Between Columns @ Right Edge of Col #2 Ru/Phi As Req'd Ru/Phi As Req'd RufPhi As Req'd ACI 9-1 0.00 psi -0.344 in2/ft 0.00 psi -0.344 in2/ft ).00 psi -0.344 int/ft ACI 9-2 29.88 psi 0.344 in2/ft 103.91 psi 0.872 in2/ft 54.94psi 0.455 in2/ft ACI 9-3 32.38 psi 0.344 in2tft 106.41 psi 0.893 in2/ft 52.44psi 0.434 in2tft ACI Factors (per ACI; applied internally to entered loads) KS4n" +f`3''.b:iih'RP,SC..LtiiK-NYi1:::Y' -' ...,".. ,. -. •.' _. - + LSe ACI 9-1 & 9-2 DL 1.400 ;fit.'.. •'�aSr2?SiikLn' •. .�'.r+l%dev/. ...t&.1:s:'Ga':'J.k:)ivlr,^wCVtuk��r`e5.31in:ZS1a,.+..,.t,,:Uc�:.'. Sn Ys�S::. ACI 9-2 Group Factor 0.750 UBC 1921.2.7 "1.4" Factor 1.400 ACI 9-1 & 9-2 LL 1.700 ACI 9-3 Dead Load Factor 0.900 UBC 1921.2.7 "0.9" Factor 0.900 ACI 9-1 & 9-2 ST 1.700 ACI 9-3 Short Term Factor 1.300 ....seismic = ST " : 1.100 Z�Z. e Earth Systems 1i Southwest CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED CONMRucT r)m Consulting Engineers and Geologists TITLE 24 REPORT Title 24 Report for: The Sonnenberg Residence 52-365 Via Dona La Quinta, CA 92253 Project Designer: Jeffrey L. Miller, Architect 834 S.W. St. Clair Ave. #202 Portland, OR 97205 (503) 222-2324 Report Prepared By: CJ McFadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 FBCUILDINOG F LA QUINTA & SAFETY DEPT. PPROVED CONSTR TION Job NurI10C i au�7l��J� r I 1 Date: 6/22/2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. i This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number: 3665 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 i I TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 8 Form C -2R Computer Method Summary 10 Form ENV -3 Proposed Construction Assembly 17 HVAC System Heating and Cooling Loads Summary 18 Room Load Summary 22 Room Heating Peak Loads 26 Room Cooling Peak Loads 30 EnergyPro 3.1 By EnergySoft Job Number: User Number: 3665 Component Type o Certificate of Compliance: Residential (Part'l of 2) CF -1 R ' The Sonnenberg Residence 3/22/2005 Project Title Date 52-365 Via Dona La Quinta Wood 0.057 ' Project Address Slab On Grade BuildinE Permit # - BREEZE AIR CONDITIONING (760) 346-0855 Plan Chick / Date Documentation Author Telephone n/a 0.756 Computer Performance 15 Solid Wood Door Field Check / Date ' Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Raised Floor ' Total Conditioned Floor Area: 4,596 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 3,677 ft2 Exterior Floor / Over Open Space Building Type: - 65.4 ' (check one or more) 0.27 X❑ Single Family Detached ❑ Addition Screen ❑ Single Family Attached ❑ Existing Building ❑ ' ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (Southeast) 135 deg Floor Construction Type: ® Slab Floor ' Number of Dwelling Units: 1.00 0.45 Number of Stories: 2 ® Raised Floor Component Type Frame Type Const. Assembly U -Value Location/Commerits (attic, garage, typical, etc.) R-38 Roof (R.38.2xl4.16) Wood 0.026 Exterior Roof R-21 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Solid Wood Door Wood 0.387 Exterior Door Raised Floor Wood 0.037 Exterior Floor / Over Open Space FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Rear (North) 171.0 0.44 0.23 Bug Screen ❑ x❑ ❑ X❑ Front (South) 65.4 0.44 0.27 Bug Screen X❑ ❑ ❑X❑ Front (South) 65.4 0.45 0.20 Bug ScreenX❑ ❑ ❑ x❑ Left (West) 227.8 0.44 0.23 Bug Screen❑ X❑ ❑ X❑ Right (Northeast) 84.0 0.44 0.23 Bug Screen ❑ X❑ ❑ X❑ Front (Southeast) 35.0 0.45 0.20 Bug ScreenX❑ ❑ ❑ x❑ Front (South) 11.0 0.44 0.23 Bug Screen X❑ ❑ ❑ X❑ Left (Southwest) 30.0 0.44 0.23 Bug ScreenX❑ 1:1 ElX❑ Left (West) 98.1 0.45 0.20 Bug Screen X❑ El El 21Left (West) 65.4 0.44 0.27 Bug Screen X❑ ❑ ❑ x❑ Rear (Northwest) 11.0 0.44 0.23 Bug Screen ❑ x❑ ❑ x❑ Rear (North) 65.4 0.44 0.27 Bug Screen ❑ x❑ ❑ x❑ -Run Initiation Time: 06 06105 06:38:40 Run Code: 1118065120 [EnergyPro 3.1 By Ener Soft User Number. 3665 Job Number: Pa e:3 of 38 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R ' The Sonnenberg Residence 6/22/2005 Project Title Date 52-365 Via Dona La Quinta ' Project Address Building Permit # - BREEZE AIR CONDITIONING (760) 346-0855 Plan Check / Date Documentation Author Telephone Shading Computer Performance 15 Field Check / Date ' Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION (North) ' Total Conditioned Floor Area: 4,596 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 3,677 ft2 0.20 Building Type: Screen ' (check one or more) X❑ Single Family Detached ❑ Addition X❑ ❑ Single Family Attached ❑ Existing Building (North) ' ❑ Multi -Family ❑ Existing Plus Addition 0.44 Front Orientation: (Southeast) 135 deg Floor Construction Type: ® Slab Floor ' Number of Dwelling Units: 1.00 X❑ Number of Stories: 2 ® Raised Floor ' BUILDING Component Type FENESTRATION Const. Frame Assembly Location/Comments Tvpe U -Value (attic, garage, typical, etc.) Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Rear (North) 32.7 0.45 0.20 Bug Screen ❑ X❑ ❑ X❑ Rear (North) 65.4 0.44 0.27 Bug Screen X❑ ❑ ❑ X❑ Rear (North) 32.7 0.45 0.20 Bug ScreenX❑ ❑ ❑ X❑ Right (East) 51.4 0.45 0.20 Bug Screen ❑ X❑ ❑ a Right (East) 32.7 0.44 0.27 Bug Screen ❑ X❑ ❑ X❑ Right (East) 45.0 0.44 0.23 Bug Screen ❑ X❑ ❑ X❑ Front (South) 79.0 0.44 0.23 Bug Screen ❑X❑ ❑ X❑ Front (South) 65.4 0.44 0.27 Bug Screen ❑X❑ ❑ X❑ Front (South) 65.4 0.45 0.20 Bug Screen ❑ X❑ ❑ X❑ Left (West) 65.7 0.45 0.20 Bug Screen ❑ o ❑ o Right (Northeast) 19.2 0.44 0.27 Bug Screen ❑ X❑ ❑X❑ Front (Southeast) 19.2 0.44 0.27 Bug Screen ❑ X❑ ❑X❑ Run Initiation Time: 06/06/05 06:38:0 Run Code: 1118065120 Ener Pro 3.1 By Ener Soft User Number. 3665 . Job Number: Pa e:4 of 38 1 Certificate of Compliance: Residential (Part 1 Of 2) CF -1 R ' The Sonnenberg Residence h/22/2005 Project Title Date 52-365 Via Dona La Quinta Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check/Date Documentation Author Telephone ' Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION ' Total Conditioned Floor Area: 4,596 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 3,677 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (Southeast) 135 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 2 ® Raised Floor BUILDING Component Type 1 FENESTRATION Const. Frame Assembly Location/Comments Tvoe a -Value (attic, garage. tvoical, etc. Shadina Devices Type Orientation Area Fenestration Exterior Dverhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (Southeast) 30.0 0.44 0.23 Bug Screen ❑x❑ ❑ x❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 06/06/05 06.38:40 Run Code: 1118065120 Ener Pro 3.1 By Ener Soft User Number. 3665 Job Number. Pa e:5 of 38 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R ' The Sonnenberg Residence 3/22/2005 Project Title Date ' HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Desigr Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / ' pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC #1 Central Fumane 80% AFUE Ducts in Attar. 42 Sethark HVAC #2 ' Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC #3A & #3B Split Heat Pump 6.90 HSPF Ducts in Attic 4.2 Setback HVAC #4 ' Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 42 S tha .k HVAC #1 Snlat Air Conditioner 14 0 SEER Ducts in Attar 4.2 Sethack HVAC #2 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC #3A & #3B Split Heat Pump 12.6 SEER Ducts in Attic 4.2 Setback HVAC #4 WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A O.Smath FGR -75 Large Gas Recirc/Time+Temp 2 76,000 75 0.72 0.0000 0.0 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, lift energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Ifitle 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: BREEZE AIR CONDITIONING ' Title/Firm: Jeffrey L. Miller, Architect Address: 834 S.W. St. Clair Ave. #202 Telephone: Portland. OR 97205 ' Telephone: (503) 222-2324 Lic. #: ' (signature) Enforcement Agency ' Name: Title/Firm: Address: Telephone: ' EnergyPro 3.1 By EnergySo User Number: 3665 (date) Name: CJ McFadden Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PACE PALM DESERT, CA 922.11 Telephone: (760) 346-0855 &- = (signature) el Z (dat ) Job Number: of 38 Certificate of Comaliance: Residential (Addendum) CF -1 R The Sonnenberg Residence 6/22/2005 Project. Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System "HVAC #1 " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 68 sqft Tile in Mortar Interior Mass, 0.75' thick at Master Suit HIGH MASS Design(see C -2R) - Verify Thermal Mass: 68 sqft Exposed Slab Floor, 4.00" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 612 sqft Covered Slab Floor, 4.00" thick at Master Suite The HVAC System "HVAC #2 " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 116 sqft Tile in Mortar Interior Mass, 0.75" thick at Bedrooms 2 & 3 / Gallery HIGH MASS Design(see C -2R) -Verify Thermal Mass: 116 sqft Exposed Slab Floor, 4.00" thick at Bedrooms 2 & 3 / Gallery HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1044 sqft Covered Slab Floor, 4.00" thick at Bedrooms 2 & 31 Gallery The HVAC System "HVAC #3A & #313 " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1653 sqft Tile in Mortar Interior Mass, 0.75' thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1653 sqft Exposed Slab Floor, 4.00" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 184 sqft Covered Slab Floor, 4.00" thick at Living Area The HVAC System "HVAC #4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. 'HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC #1 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater mus•: provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #2 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater mist provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #3A & #313 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. I EnergvPro 3.1 By EnergvSoft User Number. 3665 Job Number. Page:7 of 38 I Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. CESIGNER ENFORCEMENT Building Envelope Measures ❑X 11,90(.): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturers labeled R -Value. ' 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does X§ not apply to exterior mass walls). ❑ ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no ❑§ greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ § 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures a§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA. ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. X] §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:8 of 38 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an. asterisk (") may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) FIV I'§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. a§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specifiedcriteria Lighting Measures R7§150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. a§ 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement iallowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 3665 Job Number: Page:9 of 38 Computer Method Summary (Part 1 of 3) C -2R ' _T_hidence �/ 6/22/20Q5 Project Title Date _52=3.65_Via-Dona—La-Quint a ■I Project Address Building Permit # ' BREEZE AIR CO_NDIZLONING, 11 (760) 346-0855 Documentation Author ►1 Telephone Plan Check/Date Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone ' Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Heating 5.46 7.47 -2.01 'Space Space Cooling 39.61 37.77 1.84 Domestic Hot Water 6.20 4.53 1.67 1:1 51.27 49.77 1.51 'Totals Percent better than Standard: ■ 2.9% BUILDING COMPLIES Total Conditioned Floor Area: 4,596 ft2 Floor Construction Type: Raised Floor Slab Floor ' Building Type: Single Fam Detached MA RVITF 11 ff VITA PA W4 I III I Building Front Orientation: (Southeast) 135 deg Total Fenestration Area: 33.4% Number of Dwelling Units: 1.00 Total Conditioned Volume: 45,839 ft 3 ' Number of Stories: 2 Total Conditioned Slab Area: 3,677 ft 2 ZONE INFORMATION # of Thermostat Vent 'BUILDING Zone Name Floor Area Volume Units Zone Type Type Hgt. Area _MVAC #1 680 F; 800 0_15 Conditioned S -tom hark _8 _n/ -H #2 1,160 11,020 91.25 Conditioned— Sethack 8 n/e JiVA�#3A ,.#3g 1 837 19,288 --GAO– Conditioned Setback 8 n/a ' JiVgC #4 919 8.730 0.20 Conditioned Setback 8 n/a Solar OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference Location / Comments Roof— 680 0.026 345 _ 0 Wall 407 0.057 0 g.0_ Wall—_ 107 0.057 90 90 Wall 324 0.057 180 9A Wall—_��M 0.057 270 90 .Roof_ 671 0.026_ —345 —0 Wall 53 0.057 0 90 Wall 218 0.057 45 90 Wall 248 0.057 135 90_ .nnnr 19 0.387 135 g0 wall 69 0.057 180 90 Wall_ 150 0.057 225 90 Wall_ 189 0.057 270 go r Wall_ 21 0.057 315 9.0 Roof— 1,692 0.026 345 Q Wall 584 0.057 Q 9.0 Wall 411 0.057 90 90_ -Wall 45 0.057 135 90 Wall— 644 9.057 180 90 .Door 19 0.3$7- 180 90 Wall_ 430 0.057 270 90 .F�ooL 0 037 0 180 Roof— _9 A 0.026_ —345 _ 0 -Wall 215 0.057 n 9Q Wall_ 46 0 057 455 , 90 .Wall— 356 0—O -5Z 90 90 Wall 102 9 057- 135 94 Wall 158 0.057 180 90 Wall_ ._264 0.057 270 9Q l Run Initiation Time: 06/06105 06:38:40 Run Code: 1118065120 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 10 of 38 j �/ ■ A. ►'1 ■I NA 1 R - I 1. 11 ■;.. HKAG ►1 ■ A- ■111111111MARTATF11WAYNAM. �/ ■ MOM KI■NEW .. ...... 1 ■111111111014RIAIFIRAMM �/ ■111111111MARTATFIlffiYAWAW4715 1:1 ■ A . ►:1 ■ :. . /:/ ■= MA RTATF1 ■= MA RVITF 11 ff VITA PA W4 I III I 11 ■WMARTATF11WITWA 11 ■ l Run Initiation Time: 06/06105 06:38:40 Run Code: 1118065120 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 10 of 38 j Computer Method Summary (Part 2 of 3) C -2R The Sonnenberg Residence 6/22/2005 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments 1 Wind Avi Rear (Aor 13A 0.440 _023_ 0 gn Kolbe & Kolbe ZONE #1 2 Window Rear (North) 13.0 0.440 0.23 0 90 Kolbe & Kolbe ZONE #1 3 Window Rear (North) 13.0 0.440 0.23 0 90 Kolbe & Kolbe ZONE #1 4 Window Rear (North) 13.0 0.440 0.23 0 90 Kolbe & Kolbe ZONE #1 5 Window Rear (North) 13.0 0.440 0.23 0 90 Kolbe & Kolbe ZONE #1 6 Window Rear (North) 30.0 0.440 0.23 0 90 Kolbe & Kolbe ZONE #1 L Window Front (South) 32.7 0.440 0.27 180 90 Kolbe & Kolbe ZONE #1 8 Window Front (South) 32.7 0.450 0.20 180 90 Kolbe & Kolbe ZONE #1 6 Window Front (South) 32.7 0.450 0.20 180 90 Kolbe & Kolbe ZONE #1 AD Window Front (South) 32.7 0.440 0.27 _18_0 90 Kolbe & Kolbe ZONE #1 11 Window Left (West) 41.0 0.440 0.23 270 90 Kolbe & Kolbe ZONE #1 12 Window Rear (North) 30.0 0.440 0.23 0 90 Kolbe & Kolbe ZONE #2 13 Window Rear (North) X0.0 0.440 0.23 0_ 90 Kolbe & Kolbe ZONE #2 14 Window Right (Northeast) 13.0 0.440 0.23 45 90 Kolbe & Kolbe ZONE #2 15 Window Right (Northeast) 11.0 0.440 0.23 45 90 Kolbe & Kolbe ZONE #2 16 Window Right (Northeast) 30.0 0.440 0.23 45 90 Kolbe & Kolbe ZONE #2 17 Window Right (Northeast) 30.0 0.440 0.23 45 90 Kolbe & Kolbe ZONE #2 18 Window Front (Southeast) 35.0 0.450 0.20 135 90 Kolbe & Kolbe ZONE #2 19 Window Front (,South) 11.0 0.440 0.23 180 90 Kolbe & Kolbe ZONE #2 20 Window Left (Southwest) 30.0 0.440 0.23 225 90 Kolbe & Kolbe ZONE #2 21 Window Left (West) 32.7 0.450 0.20 270 90 Kolbe & Kolbe ZONE #2 .22 Window Left (West) 32.7 0.450 0.20 270 90 Kolbe & Kolbe ZONE #2 23 Window Left (West) 32.7 0.450 0.20 270 90 Kolbe & Kolbe ZONE #2 24 Window Left (West) 32.7 0.440 0.27 270 90 Kolbe & Kolbe ZONE #2 25 Window Rear (Northwest) 11.0 0.440 0.23 315 90 Kolbe & Kolbe ZONE #2 26 Window Rear (North) 32.7 0.440 0.27 0 90 Kolbe & Kolbe ZONE #3A & #3B 27 Window Rear (North) 32.7 0.450 0.20 0 90 Kolbe & Kolbe ZONE #3A & #3B 28 Window Rear (North) 32.7 0.440 0.27 0 90 Kolbe & Kolbe ZONE #3A & #3B 29 Window Rear (North) 32.7 0.440 0.27 0 90 Kolbe & Kolbe ZONE #3A & #3B INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 _ 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 _ 7 Bug Screen 0.76 7.0 4.7 7.0 0.1 7.0 7.0 8 Bug Screen 0.76 7.0 4.7 7.0 0.1 7.0 7.0 9 Bug Screen 0.76 7.0 4.7 7.0 0.1 7.0 7.0 10 Bug Screen 0.76 7.0 4.7 7.0 0.1 7.0 7.0 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 7.0 5.0 8.0 0.1 8.0 8.0 19 Bug Screen 0.76 5.0 2.2 8.0 0.1 8.0 8.0 20 Bug Screen 0.76 5.0 6.0 6.0 0.1 6.0 6.0 Ti Bug Screen 0.76 7.0 4.7 8.0 0.1 8.0 8.0 22 Bug Screen 0.76 7.0 4.7 8.0 0.1 8.0 8.0 23 Bug Screen 0.76 7.0 4.7 8.0 0.1 8.0 8.0 _ 24 Bug Screen 0.76 7.0 4.7 8.0 0.1 8.0 8.0 _ 25 Bug Screen 0.76 _ 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 7.0 4.7 7.0 0.1 7.0 7.0 EnergvPro 3.1 By EnergvSoft User Number: 3665 Job Number: Page: 11 of 38 Computer Method Summary (Part 2 of 3) C -2R The Sonnenberg Residence 6/22/2005 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 3.0. Window Rear (North) 32.7 -0.440_ 097 0_ _90. Kolbe & Kolbe ZONE #3A & #3B 31 Window Rear (North) 32.7 0.450 0.20 0 90 Kolbe & Kolbe ZONE #3A & #3B ' 32 Window Right (East) 32.7 0.450 0.20 90 90 Kolbe & Kolbe ZONE #3A & #36 33 Window Right (East) 32.7 0.440 0.27 90 90 Kolbe & Kolbe ZONE #3A & #3B 34 Window Right (East) 18.7 0.450 0.20 90 90 Kolbe & Kolbe ZONE #3A & #3B 35 Window Right (East) 11.0 0.440 0.23 90 90 Kolbe & Kolbe ZONE #3A & #3B ' 3a Window Front (,South) 41.0 0.440 0.23 180 90 Kolbe & Kolbe ZONE #3A & #3B 37 Window Front (South) 32.7 0.440 0.27 180 90 Kolbe & Kolbe ZONE #3A & #3B 38 Window Front (_South) 32.7 0.440 0.27 180 90 Kolbe & Kolbe ZONE #3A & #3B 39 Window Front (South) 32.7 0,450 x.20 180 90 Kolbe & Kolbe ZONE #3A & #3B 40 Window Front (South) 32.7 0.450 0.20 180 90 Kolbe & Kolbe ZONE #3A & #3B 41 Window Front (South) 20.0 0.440 0.23 180 90 Kolbe & Kolbe ZONE #3A & #3B A2 W1ad054-Left (West) 32.7 _0-440 0-27 270 _90 Ko be_& Kolbe ZONE #3A & #38 43 Window Left (West) 32.7 0.450 0.20 270 90 Kolbe & Kolbe ZONE #3A & #3B 44 Window Left (West) 42.1 0.440 0.23 270 90 Kolbe & Kolbe ZONE #3A & #3B ' 45 Window Left (West) 17.5 0.450 0.20 270 90 Kolbe & Kolbe ZONE #3A & #3B 46 Window Left (West) 54.0 0.440 0.23 270 90 Kolbe & Kolbe ZONE #3A & #3B 47 Window Rear (North) 8.0 0.440 0.23 0 90 Kolbe & Kolbe ZONE #4 A8 Window Rear (North) 8.0 0.440 0.23 0 90 Kolbe & Kolbe ZONE #4 ' 49 Window Right (Northeast) 19.2 0.440 0.27 45 90 Kolbe & Kolbe ZONE #4 50 Window Right (East) 16.0 0.440 0.23 90 90 Kolbe & Kolbe ZONE #4 51 Window Right (East) 18.0 0.440 0.23 90 90 Kolbe & Kolbe ZONE #4 52 Window Front (Southeast) 19.2 0.440 0.27 135 90 Kolbe & Kolbe ZONE #4 ' 53 Window Front (Southeast) 10.0 0.440 0.23 135 90 Kolbe & Kolbe ZONE #4 54 Window Front (Southeast) 10.0 0.440 0.23 135 90 Kolbe & Kolbe ZONE #4 55 Window Front (Southeast) 10.0 0.440 0.23 135 90 Kolbe & Kolbe ZONE #4 56 Window Front (South) 9.0 0.440 0.23 180 90 Kolbe & Kolbe ZONE #4 57 Window Front (South) 9.0 0.440 0.23 180 90 Kolbe & Kolbe ZONE #4 58 Window Left (West) 18.0 0.440 0.23 270 90 Kolbe & Kolbe ZONE #4 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 30 t Bug Screen 0.76 7.0 4.7 7.0 0.1 7.0 7.0 31 Bug Screen 0.76 7.0 4.7 7.0 0.1 7.0 7.0 32 Bug Screen 0.76 33 Bug Screen 0.76 ' 34 Bug Screen 0.76 55 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 ' 38 Bug Screen 0.76 - 39 Bug Screen 0.76 _ 40 Bug Screen 0.76 41 Bug Screen 0.76 ' 42 Bug Screen 0.76- 7.0 4.7 8.0 0.1 8.0 8.0 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 ' 47 Bug Screen 0.76 48 Bug Screen 0.76 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 _ S8 Bug Screen 0.76 ' Run Initiation Time: 06106105 06.38.40 Run Code: 1118065120 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 12 of 38 Computer Method Summary (Part 2 of 3) C -2R The Sonnenberg Residence 6/22/2005 Project Title Date FENESTRATION SURFACES Bug Screen 0.76 61 Bug Screen ' 62 Bug U- 0.76 Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments _59. Windows ONesa is() 0.440_ 023 270 _90 Kolbe & Kolbe ZONE #4 60 Window Left (West) 10.9 0.440 0.23 270 90 Kolbe & Kolbe ZONE #4 61 Window . Left (West) 10.9 0.440 0.23 270 90 Kolbe & Kolbe ZONE #4 62 Window Left (West) 10.9 0.440 0.23 270 90 Kolbe & Kolbe ZONE #4 63 Window Left (West) 8.0 0.440 0.23 270 90 Kolbe & Kolbe ZONE #4 64 Window Left (West) 16.0 0.440 0.23 270 90 Kolbe & Kolbe ZONE #4 ' 65 Window Left (West) 15.5 0.450 0.20 270 90 Kolbe & Kolbe ZONE #4 INTERIOR AND EXTERIOR SHADING # Gv#crinr ChnAl Tvnc cur_r, 60 Bug Screen 0.76 61 Bug Screen 0.76 _ 62 Bug Screen 0.76 63 Bug Screen 0.76 64 Bug Screen 0.76 65 Bug Screen 0.76 Left Fin Right Fin Dist. Len. Hgt. Dist. Len. Hgt. EnergvPro 3.1 By EnergvSoft User Number: 3665 Job Number: Paoe:13 of 38 CoMputer Method Summary (Part 3 of 3) C-2R ' The Sonnenberg Residence 6/22/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN ' Area Thick. Heat Inside Locaton Type (sf) (in.) Cap. Cond. Form 3 Reference R-Val. Comnents Tile in Mortar 1,$ -025 940_67 n/a a ZONE #1 / Interior Mass ' Concrete, Heavyweight 68 4_00 28 0_98 n/a 0 ZONE #1 / Slab on Grade Q-Q- crr . Heavyweight 612 4_00 28 0_98 n/a 2 ZONE #1 / Slab on Grade Tile in Mortar 116 0.75 24 0.67 n/a 0 ZONE #2 / Interior Mass Cooc[e1eight 116 4.00 28 0_98 n/a 0 ZONE #2 / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R-Val. Depth Location / Comments ' Slab Perimeter 13 0.76 0.0 0 ZONE #1 Slab— etimeter X16 0.76 _0. Q 0 ZONE #1 Slab Perimeter 14 0.76 0.0 0 ZONE #2 Slab Perimeter 129 0.76 0.0 —0 ZONE #2 ' .Slab_eerimeter 238 0.76 0.0 0 ZONE #3A & #36 HVAC SYSTEMS 'Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R-Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC: #1 ' Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC #2 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC: #3A & #36 Split Heat Pump 6.90 HSPF Ducts in Attic 4.2 Setback HVAC #4 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / ' heat pump, evap. cooling) (SEER) (attic, etc,) R-Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC: #1 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC #2 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC #3A & #38 ' Split Heat Pump 12.6 SEER Ducts in Attic 4.2 Setback HVAC #4 WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recoaery Standby R-Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O.Smith FGR-75 LaMe Gas Recirc/Time+Temp 2_ Z&000 75 0.72 0.0000 0.0 ' 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Los:.. ' For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. EnergyPro 3.1 By EnerovSoft User Number: 3665 Job Number: Paae:14 of 38 1 1 Computer Method Summary (Part 3 of 3) C -2R ' The Sonnenberg Residence pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Hydronic Piping Pipe Pipe Insul. 6/22/2005 Project Title 1 Cooling Equipment Minimum Duct Date THERMAL MASS FOR HIGH MASS DESIGN ' heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments HEATING SYSTEMS Rated' Tank ' Area Thick. Heat 1 or Recovery Standby R -Value Inside Location Type (sq (in.) Cap. Cond. Form 3 Reference R -Val. Comments Heavyweight 11,44 40 98 -0-11, n/a _2 70"NE $ /Slab on rnwl, 'Concrete, Tile in Mortar 1.653 0_75 24 0_67 n/a 0 ZONE #3A & #313 / Interior Mass Concre e Heavyweight 1.65.3 4.00 28 0.98 n/a 0 ZONE #3A & #313 / Slab on Grade Concrete, Heavyweight 184 4_00 28 0_98 n/a 2 ZONE 43A & #3B / Slab on Grade ' PERIMETER LOSSES F2 Insulation Length Factor R -Val. Depth Location / Comments 'Type Slab Perimeter 27 0.76 0.0 ZONE #3A & #3B HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Loca-ion / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. 1 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / ' heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments HEATING SYSTEMS Rated' Tank Energy Facts Tank Insul. 'WATER Water Heater Water Heater Distribution # in Input Cap. 1 or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. ' For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. i EnerpyPro 3.1 By EnerovSoft User Number: 3665 Job Number. Paae:15 of 38 i I Computer Method Summary (Addendum) C -2R ' The Sonnenberg Residence 6/22/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. Tie local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System "HVAC #1 " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 68 sqft Tile in Mortar Interior Mass, 0.75' thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 68 sqft Exposed Slab Floor, 4.00" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 612 sqft Covered Slab Floor, 4.00" thick at Master Suite The HVAC System "HVAC #2 " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) -Verify Thermal Mass: 116 sqft Tile in Mortar Interior Mass, 0.75" thick at Bedrooms 2 & 3 /Gallery HIGH MASS Design(see C -2R) -Verify Thermal Mass: 116 sqft Exposed Slab Floor, 4.00" thick at Bedrooms 2 & 3 /Gallery HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1044 sqft Covered Slab Floor, 4.00" thick at Bedrooms 2 & 3 Gallery The HVAC System "HVAC #3A & #3B " includes credit for a Radiant Barrier installed per Section 8.13 of the Residenflal Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1653 sqft Tile in Mortar Interior Mass, 0.75" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1653 sqft Exposed Slab Floor, 4.00" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 184 sqft Covered Slab Floor, 4.00" thick at Living Area The HVAC System "HVAC #4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. 'HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a -orm CF -6R. I Plan I Field The HVAC System "HVAC #1 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must: provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #2 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #3A & #38 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS -ater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:16 of 38 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 ' PROJECT NAME DATE The Sonnenberg Residence 6/22/2005 COMPONENT DESCRIPTION DESCRIPTION 0.010 OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 ASSEMBLY NAME R-21 Wall .21.2x6.16 0.31 7 0.37 8 2.60 ASSEMBLY Floor INSIDE SURFACE AIR FILM 0.680 23.11 TYPE (check one) X Wall LL LL Ceiling / Raaf Cl FRAMING MATERIAL Wood H p FRAMING % 15 % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) CONSTRUCTION COMPONENTS ' A THICK- NESS FRA (in.) ❑ ❑ ❑ © ❑ ' DESCRIPTION 0.010 OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.31 7 0.37 8 2.60 9 0.68 INSIDE SURFACE AIR FILM FRA (in.) ❑ ❑ ❑ © ❑ ' 0.875 0.010 0.375 5.500 0.625 0.175 0.060 0.060 0.465 0.465 SUBTOTAL R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.1751 0.175 0.060 0.060 0.465 0.465 21.000 5.445 0.5621 0.562 0.31 2.63 0.37 0.98 2.60 0.26 0.68 0.6801 0.680 23.11 7.56 'HEAT CAPACITY (Optional) WALL. WEIGHT (lbs/sf", SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 8.46 0.20 1.69 0.06 0.35 0.02 1.06 0.29 0.31 2.63 0.37 0.98 2.60 0.26 0.68 14.8 TOTAL HC 3.7 Rc Rf 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. t0.0433 X 0.85 + 0.1323 X 0.15 '11 Rc 1 - (Fr -/6 1110)' 1 I Rf Fr% 1100 ASSEMBLY U -VALUE COMMENTS 1 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 17 of 38 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Sonnenberg Residence 6/22/2005 SYSTEM NAME FLOOR AREA HVAC #1 680 Number of Systems 1I Heating System Output per System 54,100 Total Output (Btuh) 54,100 Output (Btuh/sqft) 79.6 Cooling System Output per System 36,000 Total Output (Btuh) 36,000 Total Output (Tons) 3.0 Total Output (Btuh/sqft) 52.9 Total Output (sgft/ron) 226.7 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 1.76 Airflow (cfm/Ton) 400.0 Outside Air (%) 4.2 Outside Air (cfm/sqft) 0.08 Note: values above given at ARI conditions CAI I NU OTO I C IYI 1"0 T V r7 KV IYI C I RI to J 24.0 of 67.4 of Outside Air 51 cfm 69.3 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 778 16,701 1,867 420 17,447 0 835 872 0 0 5 1,952 1,268 51 2,496 0 0 835 872 20323 3,136 21,687 HS26-036/G40UH36A-70X (3) 29,375 2,190 54,100 Total Adjusted System Output 28,375 2,190 54,100 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 109.2 of Heating Coil Supply Fan 1200 cfm 109.2 of Supply Air Ducts 108.5 of ROOMS 70.0 of �% Return Air Ducts %i (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) I 114.1 / 80.3 of 80.2 / 64.8 of 57.5 / 56.0 of 57.5 / 56.0 of Supply Air Ducts Outside Air O 51 cfm Cooling Coil Supply Fan 58.1 / 56.3 of 1200 cfm 461% R.H. FROOMS 178.6 / 64.1 of 78.0 / 63.8 of h Return Air Ducts `S EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 18 of 38 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Sonnenberg Residence 6/22/2005 SYSTEM NAME FLOOR AREA HVAC #2 1,160 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK IICOILHTG.PEAK 24,436 CFM ISensiblel Latent I I CFM I Sensible 1,187 24,436 3,084 537 22,042 0 1,222 1,102 0 0 87 3,324 2,013 87 4,260 0 0 1,222 1,102 30 203 5 097 1 28,507 HS26-048/G40UH48B-090X (4) 38,695 3,892 72,100 Total Adjusted System Output 38,695 3,892 72,100 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm I Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 OF 66.9 OF 108.60E 108.6 OF Supply Air Ducts Outside Air '0 87 cfm Heating Coil Supply Fan 108.0 OF 1600 cfm ROOMS 70.0 OF 69.4 OF 114.1 /80.3 OF Outside Air 87 cfm 78.7/64.6 OF f% Return Air Ducts ; 80.6/65.60F = 58.2 / 56.8 OF 58.2 / 56.8 OF Cooling Coil Supply Air Ducts Supply Fan 58.9 / 57.1 OF 1600 cfm49-.8% R.H. ROOMS 78.0 / 64.4 OF Return Air Ducts I j EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:19 of 38 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME The Sonnenberg Residence DATE 6/22/2005 SYSTEM NAME HVAC #3A & #3B FLOOR AREA 1,837 ENGINEERING CHECKS SYSTEM LOAD Number of Systems I 2 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible Total Room Loads 2,153 45,961 5,205 992 41,317 Return Vented Lighting 0 Return Air Ducts 2,298 2,066 Return Fan 0 0 Ventilation 138 5,270 3,396 138 6,753 Supply Fan 0 0 Supply Air Ducts 1 2,298 2,066 TOTAL SYSTEM LOAD 55 828 8,60 52,201 Heating System Output per System 72,100 Total Output (Btuh) 144,200 Output (Btuh/sqft) 78.5 Cooling System Output per System 48,000 Total Output (Btuh) 96,000 Total Output (Tons) 8.0 Total Output (Btuh/sqft) 52.3 Total Output (sgft/Ton) 229.6 Air System HVAC EQUIPMENT SELECTION CFM per System 1,600 144,200 HS26-048/G40UH48B-090X (4) 78,190 6,094 Airflow (cfm) 3,200 Airflow (cfm/sgft) 1.74 Airflow (cfm/Ton) 400.0 Total Adjusted System Output (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK 78,190 6,094 ALg 2 pm 144,200 Outside Air (%) 4.3 Outside Air (cfm/sqft) 0.07 Jan 12 ann Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 OF 67.4 OF 109.2 OF 109.2 OF Outside Air 138 cfm Heating Coil Supply Fan 3200 cfm 69.4 of Return Air Ducts 09' Supply Air Ducts 108.6 of ROOMS 70.0 of I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 114.1 / 80.3 OF Outside Air 138 cfm 78.7/64.1 0F iI 80.2 / 64.9 OF 57.6 / 56.1 OF 57.6 156.1 OF O` Supply Air Ducts Cooling Coil Supply Fan 58.2 / 56.4 of 3200 cfm 46.3% R.H. ROOMS i 78.0 / 63.9 OF Return Air Ducts EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page•20 of 38 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME The Sonnenberg Residence DATE 6/22/2005 SYSTEM NAME HVAC #4 FLOOR AREA 919 ENGINEERING CHECKS ISYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible Total Room Loads 1,060 22,084 2,443 816 13,042 Return Vented Lighting 0 Return Air Ducts 1,104 652 Return Fan 0 0 Ventilation 69 2,639 1,642 69 3,395 Supply Fan 0 0 Supply Air Ducts 11104 652 TOTAL SYSTEM LOAD 26 93 4 085 17,741 Heating System Output per System 48,000 Total Output (Btuh) 48,000 Output (Btuh/sgft) 52.21 Cooling System Output per System 48,000 Total Output (Btuh) 48,000 Total Output (Tons) 4.0 Total Output (Btuh/sgft) 52.2 Total Output (sgft/Ton) 229.8 Air System HVAC EQUIPMENT SELECTION CFM per System 1,600 30,256 HP26-048/CB30M-51 (4 Ton) 38,175 4,124 Airflow (cfm) 1,600 Airflow (cfm/sqft) 1.74 Airflow (cfm/Ton) 400.0 Total Adjusted System Output 38,175 4,124 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 2 pm 30,256 Outside Air (%) 4.3 Outside Air (cfm/sgft) 0.08 Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 OF 67.7 OF 85.20 85.2 OF Supply Air Ducts Outside Air 0 w 69 cfm 84.8 OF Heating Coil Supply Fan 1600 cfm ROOMS 70.0 OF 69.6 OF I ec Return Air Ducts OOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 114.1 / 80.3 OF Outside Air, 69 cfm 78.6 / 64.4 OF 80.2 / 65.2 OF 58.1 / 56.6 OF 58.1 / 56.6 OF c'a 'ISupply Air Ducts Cooling Coil Supply Fan 58.7 / 56.9 OF 1600 cfm47.1% R.H. ROOMS 78.0 / 64.2 OF Return Air Ducts EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:21 of 38 j ROOM LOAD SUMMARY PROJECT NAME The Sonnenberg Residence DATE 6/22/2005 SYSTEM NAME HVAC #1 FLOOR AREA 680 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #1 Master Suite 1 778 16,701 1,867 778 16,701 1,867 420 17,447 PAGE TOTAL 1 778 16,701 1,867 420 17,447 TOTAL 1 778 16,701 1,867 420 17,447 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:22 of 38 ROOM LOAD SUMMARY PROJECT NAME The Sonnenberg Residence DATE 6/22/2005 SYSTEM NAME HVAC #2 FLOOR AREA 1,160 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM I SENSIBLE ZONE #2 Bedrooms 2 & 3 /Gallery 1 1,187 24,436 3,084 1,187 24,436 3,084 537 22,042 PAGE TOTAL 1 1,187 24,436 3,084 TOTAL 1 1,187 24,436 3,084 537 22,042 537 22,042 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:23 of 38 ROOM LOAD SUMMARY PROJECT NAME The Sonnenberg Residence DATE 6/22/2005 SYSTEM NAME HVAC #3A & #3B FLOOR AREA 1,837 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING FEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #3A & #36 Living Area 1 2,153 45,961 5,205 2,153 45,961 5,205 992 41,317 PAGE TOTAL TOTAL 1 2,153 45,961 5,205 IF 992 41,317 1 2,153 45,961 5,20511 992 41,317 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 24 of 38 ROOM LOAD SUMMARY PROJECT NAME The Sonnenberg Residence DATE 6/22/2005 SYSTEM NAME H VAC #4 FLOOR AREA 919 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #4 Second Floor 1 1,060 22,084 2,443 1,060 22,084 2,443 816 13,042 PAGE TOTAL 1 1,060 22,084 2,443 816 13,042 TOTAL 1 1,060 22,084 2,443 816 13,042 EnergyPro 3.1 . By EnergySoft User Number: 3665 Job Number: Page:25 of 38 ROOM HEATING PEAK LOADS Project Title Date The Sonnenberg Residence 16/22/2005 ' Room Information Design Conditions Room Name Master Suite Time of Peak Jan 12 am Floor Area 680 Outdoor Dry Bulb Temperature 24°F ' Indoor Dry Bulb Temperature 70°F Conduction Area U -Value .LT of Btu/hr 1 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 14 633 Infiltration: cnadulle x Air Sensible x Area680 X Ceiling Height ACH 50 / 60] X QT 46 = 2 814 ' Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 17,447 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 26 of 38 680.0 X X x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x xx x 0.0255 x X X x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.01 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 798 973.2 0.0566 46.0 2,535 201.4 0.4400 46.0 4,076 65.4 0.4500 46.0 1,354 Perimeter = 129.0 45.5 5,870 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 14 633 Infiltration: cnadulle x Air Sensible x Area680 X Ceiling Height ACH 50 / 60] X QT 46 = 2 814 ' Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 17,447 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 26 of 38 ROOM HEATING PEAK LOADS ' Project Title Date The Sonnenberg Residence 6/22/2005 ' Room Information Design Conditions Room Name Bedrooms 2 & 3 / Gallery Time of Peak Jan 12 am Floor Area 1,160 Outdoor Dry Bulb Temperature 24OF ' Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr ' Items shown with an asterisk (') denote conduction through an interior surface to another room. Pc ge Total: 17 482 Infiltration: x ��nea.0 X Air Sensible x Area Coiling X Ceiling Heightx ACH.So / 60] AT 46 = 4 560 ' Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 22,042 i Energ 'Pro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 27 of 38 1 671.0 X X x X X X X X x X x X X X X X X X x X X x x x X X x x X x x X X x X X X X x 0.0255 X X X x X X X X x X X x X X X x x X x X X X x X X X X X X X X X X x x x X X X 46.0 = = = = = = = = = = = = = = = 788 948.5 0.0566 46.0 2,471 228.7 0.4400 46.0 4,629 18.7 0.3872 46.0 3331 133.1 0.4500 46.0 2,755 perimeter = 143.0 45.5 6,506 ' Items shown with an asterisk (') denote conduction through an interior surface to another room. Pc ge Total: 17 482 Infiltration: x ��nea.0 X Air Sensible x Area Coiling X Ceiling Heightx ACH.So / 60] AT 46 = 4 560 ' Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 22,042 i Energ 'Pro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 27 of 38 1 ROOM HEATING PEAK LOADS Project Title Date The Sonnenberg Residence 6/22/2005 ' Room Information Design Conditions Room Name Living Area Time of Peak Jan 12 am Floor Area 1,837 Outdoor Dry Bulb Temperature 24OF ' Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr ' Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 33 334 Infiltration: I 1.001X 1.080 ' x 1 837 x Heigh x 60] x 46 = 7 982 ehedule Alr Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 41,317 L EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 28 of 38 1 1632.0 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0255 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 = = = = = = = = = = = = = 1,916 2,119.2 0.0566 46.0 5,520 429.7 0.4400 46.0 8,697 232.4 0.4500 46.0 4,811 18.7 0.3872 46.0 333 perimeter = 265.0 45.5 12,058 ' Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 33 334 Infiltration: I 1.001X 1.080 ' x 1 837 x Heigh x 60] x 46 = 7 982 ehedule Alr Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 41,317 L EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 28 of 38 1 ROOM HEATING PEAK LOADS Project Title Date The Sonnenberg .Residence 16/22/2005 Room Information Design Conditions Room Name Second Floor Time of Peak Jan 12 am Floor Area 919 Outdoor Dry Bulb Temperature 24 of Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr Raised Floor 225.0 x 0.0371 x 46.0 = 384 'Raised Conditioned Floor Wood 694.0 X 0.1730 x 0.0 = 0 Bp�f (R IR 2x14 161 919.0 x 0.0255 X 46.0 = 1,079 R-21 Wall W.21.2x6.16 1,170.4 X 0.0566 X 46.0 = 3,049 .Kolbe -&-So 227.1 X 0.4400 X 46.0 = 4.597 Kolbe & Kolbe 15.5 X 0.4500 x 46.0 = 321 x x x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = _I x x = x x = Items shown with an asterisk (•) denote conduction through an interior surface to another room. Page Total: 9 429 Infiltration: I 1.001X 1.080 X 919 X Height x 0.50 160] x 46 = 3613 chedule Ir Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 13,042 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 29 of 38 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Sonnenberg Residence 6/22/2005 Project Title Date ' Room Name Master Suite Design Indoor Dry Bulb Temperature: 780F 0 'Design Outdoor Dry Bulb Temperature: 115 F Design Temperature Difference: 37o F Conduction Area U -Value X DETD 1 X 56.0 X 35.6 X 37.0 X 37.0 X X X X X Btu/hr 972 1,962 3,279 1,089 1. Design Equivalent Temperature Difference (DETD) Page Total 7 301 I Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr CsmntWdw F North smntWdw (F(F) CsmntWdw F (North) (North) CsmntWdw F (North) CsmntWdw (F) (North) CsmntWdw D (North) FxdGlsWdw 5 (South) FrnchDr 4 (South) FrnchDr 4 South FXdGISWdW 5 South ( 0.0 x1 X x x X X1 X x x X + + + + + + + + + + 13.0 X X X x x x x x x x 15 )Y ) Y )y y �_ Y 0.256 = = = = = = = = __ = 50 ( 0.0 1 13.0 15 0.256 50 ( 0.0 1 13.0 15 0.256 50 ( 0.0 1 13.0 15) 0.256 50 ( 0.0 1 13.0 15)),-. 0.256 50 ( 0.0 30.0 15) 0.256 115 ( 32.7 1 0.0 32) 0.30 147 ( 32.7 1 0.0 32)y 0.223 109 ( 32.7 1 0.0 32)).- 0.223 109 ( 32.7 1 0.0 32)y' 0.30 147 Sched. Page Total 876 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 680 x 0.500 Watts/sgft xA3.413 Btu�1/Waft = 1,160 Occupants 1.00 X 680 X 25 Btuh/occ. / sgfdocc. = 850 Receptacle 1.00 x 680 x 1.500 Watts/sgft x Btul/Waft = 3481 Process 1.00 x 680 x .. 0.000 Wafts/sqft xBtu'11Watt = 0 Infiltration: 1.c0 x 1.080 z ELs8o x x / 60� 0 = chedule Air Sensible Area Ceiling Height ACH _T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,701 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 680 x 200 Btuh/occ. / 200 sgf�occ. = 680 Receptacle 1.00 X 680 x 0.000 Wafts/sqft x 3.41 Btu i/Waft = 0 Process 1.00 X 680 X 0.000 Wafts/sqft X 3.41 Btu 1/Waft = 0 Infiltration: chedulle x Air Latent x Area 68 X Ceiling Height 0 x ACH.50 / 60] 0.100433 = 1 187 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,867 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 30 of 38 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Sonnenberg Residence 6/22/2005 Project Title Date ' Room Name Master Suite Design Indoor Dry Bulb Temperature: 780F Design Outdoor Dry Bulb Temperature: 1 150F Design Temperature Difference: 370F Conduction Area U -Value X 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC CsmntWdw C (West) ( 0.0 X 1 + 41.0 X 73)x 0.256 ( x + x )x ( x + x )x ( x + x )x ( x + x )x ( x + x )x ( x + x )x ( x + x )� ( x + X ) Btu/hr 0 Btu/hr 766 Sched. Page Total 7s6 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 680 x 0.500 Watts/sgft xt3.1.413 Btuft/Watt = 1,160 Occupants 1.00 X 680 X 250 Btuh/occ. / sgf`IOCc. = 850 Receptacle 1.00 x 680 x 1.500 Watts/sgft x Btuih/Watt = 3481 Process 1.00 x 680 x 0.000 Watts/sqft xBtuh/Watt = 0 Infiltration: I 1.00I x I i7o8o °x s8o x x / 60] 3Z = chedule Air Sensible Area Ceiling Height ACH -/�,T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,701 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 680 x 200 Btuh/occ. / 200 sgfl/occ. = 680 Receptacle 1.00 X 680 x 0.000 Watts/sqft x 3.41 Btuh/Watt = o Process 1.00 x 680 X 0.000 Watts/sgft x 3.41 BtuhlWatt = o Infiltration: 1.00 x 4840 x 68 x Heigh x 60] 0.0)433 = 1 187 "`-- ehedule Air Latent Area Ceiling Height ACH _.W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,867 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 31 of 38 RESIDENTIAL ROOM COOLING LOAD SUMMARY ' The Sonnenberg Residence 6/22/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof R.38.2x14.16 k-21 Wall ( .21.2x6.16 Kolbe & Kolbe olid Wood Door Kolbe & Kolbe Area U -Value 671 X Bedrooms 2 & 3 / Gallery 78°F 115°F 37°F ETD 1 X 56.0 X 35.6 X 37.0 X 35.6 X 37.0 X X X X 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC CsmntWdw D (North) CsmntWdw (r) CsmntWdw F (North) (Northeast) CsmntWdw G (Northeast) CsmntWdw (D) (Northeast) CsmntWdw D (Northeast) Swn GlsEnt Dr 1 (Southeast) CsmntWdw G South CsmntWdw D (Southwest) FrnchDr 4 est ( 0.0 x X1 x x x x X x X1 x 1 + + 1 + 1 + 1 + 1 + 1 + 1 + + 1 + 30.0 X X X X X x X x x x 15) X X )X x x X X ) x 0.256 ( 0.0 30.0 15) 0.256 ( 0.0 13.0 48 0.256 ( 0.0 11.0 48) 0.256 ( 0.0 30.0 48) 0.256 ( 0.0 30.0 48)X 0.256 ( 35.0 0.0 62) 0.223 ( 11.0 0.0 32) 0.256 ( 30.0 0.0 62)x 0.256 ( 29.4 1 3.3 73 0.223 Btu/hr 959 1,912 3,723 258 2.216 9 068 Btu/hr 115 115 160 135 369 369 117 42 115 151 Sched. Page Total 1 s8s Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,160 X 0.500 Wafts/sqft x 3.413 BtuhM►att = 1,980 Occupants 1.00 X 1,160 X 250 Btuh/occ. / 200 sgft/occ. = 1,450 Receptacle 1.00 X 1,16 x 1.500 Wafts/sgft x 3.413 BtuhMaft = 5,939 Process 1.00 x 1,160 x 0.0000.000 Wafts/sqft x 3.412 Btuth/Watt = 0 Infiltration: 1-0o x 7 1,080 is 1;1so x x 0-50 / 60] 0 = Schedule Air Sensible Area Ceiling Height ACH _`.T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,436 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 1 160 x 2001 Btuh/occ. / 200 sgfUocc. = 1 160 Rece tacle 1.00 X 1 160 x 0.000 Watts/sqft x 3.41 Btu.i[Waft = 0 (Process 1.00 x 1 160 x 0.000 Watts/sgft x 3.41 Btul[Watt = 0 Infiltration: 1.00 x 4840 x 1 16 x Height x 0.50 / 60] 0.0)433 = 1 924 chedule Air Latent Area Ceiling Height ACH W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,084 IEnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 32 of 38 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Sonnenberg Residence 6/22/2005 Project Title Date Room Name Bedrooms 2 & 3 / Gallery Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X DETD1 78DF 115°F 37DF Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FrnchDr 4 (West) ( 29.4 X1 + 3.3 X 73 )X 0.223 = 151 FrnchD.r (4) (West) ( 29.4 X 1 + 3.3 X 73 ) x 0.223 = 151 WW FAGIdw 5 (West) ( 29.4 X 1 + 3.3 X 73 ) X 0.30 = 204 CsmntWdw G (Northwest) ( 0.0 x 1 + 11.0 X 48)x 0.256 = 135 ( X + X )x ( x + X )x ( x + x )x = ( x + x )x = ( x +x )x = ( x + x )x = Sched. Page Total sae Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,160 X 0.500 Watts/sgft xA-3-413 BtuhlWatt = 1,980 Occupants 1.00 X 1,160 X 250 Btuh/OCC. / sgft/occ. = 1,450 Receptacle 1.00 x 1,160 x 1.500 Watts/sgft X Btu h/Waft = 5 939 Process 1.00 x 1160 x 0.000 Watts/sqft XBtuh/Watt = 0 Infiltration: x Air Sensible Area e 'z J16p x Ceiling � x ACH / 60] Z = ss Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,436 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 160 x 200Btuh/OCC. / 200 sgfilocc. = 1 160 Receptacle 1.00 X 1 160 x 0.000 Watts/sgft X 3.41 Btu -i/Watt = 0 Process 1.00 X 1 160 X 0.000 Wafts/sqft X 3.41 Btu ilWatt = 0 Infiltration: 1.00 x 4 840 X 1 16 X 9.50 X0.50 / 60] 0.00433 = 1 924 —Schedule Air Latent Area Ceiling Height ACH :-W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,084 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 33 of 38 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Sonnenberg Residence 6/22/20Q5 Project Title Date Room Name Living Area Design Indoor Dry Bulb Temperature: 780F Design Outdoor Dry Bulb Temperature: 115 0F Design Temperature Difference: 370F Conduction Area U -Value X 1. Design Equivalent Temperature Difference (DETD) I Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Solar Gain Orientation Area SGF FxdGlsWdw 5 (North) FrnchDr (4) (North) FxdGlsWdw 5 (North) FxdGlsWdw 5 North FxdGlsWdw (5) FrnchDr 4 (North) (North) FmchDr 4 (East) FxdGlsWdw 5 (East) Fm6CIr 2 CsmntWdw G (East) East ( 0.0 X+ X+ x+ x+ X+ X1, x x x x 15)X + + + + ( 0.0 32.7 ( 0.0 0.223 ( 0.0 15)X ( 0.0 32.7 ( 0.0 0.30 ( 0.0 1 ( 0.0 1 ( 0.0 1 ( 0.0 A+ DETD 1 56.0 35.6 37.0 37.0 35.6 Page Total Unshaded Area SGF SC 32.7 x X x x X x x x X x1 15)X )X x x X ) x x 0.30 32.7 15 0.223 32.7 15)X 0.30 32.7 15) 0.30 32.7 15) 0.301 32.7 15) 0.223 32.7 73)X 0.223 32.7 73)X: 0.30 18.7 7 0.223 11.0 73) 0.256 Btu/hr 2,333 4,272 6,996 3,869 258 17 727 Btu/hr 147 109 147 147 147 109 531 717 304 206 Sched. Page Total z 567 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,837 x 0.500 Watts/sgft x 3.41 Btu hMatt = 3,135 Occupants 1.00 X 1,837 X 250 Btuh/occ. / 200 sgft/occ. = 2,296 Receptacle 1.00 x 1,837 x 1.500 Watts/sgft x 3.413 Btuh/Watt = 9,405 Process 1.00 X 1,837 x 0.000 Watts/sqft X 3.412 Btuh/Watt = _ 0 Infiltration: x 'x x E:�__Jom x / 60] _6,4201 Schedule Air Sensible Area Ceiling Height ACH 1T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 45,9611 Sched. Latent Gain Frac. Area Heat Gain Btu/hr- Occupants tu/hrOccu ants 1.00 X 1 837 x 2001 Btuh/occ. I 200 sgfflocc. = 1 837 Receptacle 1.00 X 1 837 x 0.000 Watts/sgft X 3.41 Btu i/Watt = 0 Process 1.00 X 1 837 X 0.000 Watts/sgft X 3.41 Btu -iMatt = 0 Infiltration:-Schedulex 60] AIrL to^40 x Area 83 x Ceiling x ACH.50 / OVOn433 = 3368 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 5,205 IEnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 34 of 38 RESIDENTIAL ROOM COOLING LOAD SUMMARY ' The Sonnenberg Residence 6/22/200'5 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Living Area 78°F 115°F 370E Conduction Area U -Value DETD 1 Btu/hr X X X X X X X x X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Solar Gain Orientation Area SGF CsmntWdw C (South) ExrJGIsWfJw (15) (South) FxdGlsWdw 5 (South) FrnchDr 4 (South) FmchDr (4) (South) CsmntWdw E (South) FxdGlsWdw 5 (West) FrnchDr 4 (West) CsmntWdw B FrnchDr 3 (West) West ( 0.0 x+ X+ x+ x+ X+ X1, X1 x x X + + 1 + 1 + 1 + ( 0.0 ( 0.0 ( 0.0 ( 0.0 ( 0.0 ( 29.4 ( 0.0 ( 0.0 ( 0.0 Page Total 1 01 Unshaded Area X X X x x x x X X x SGF ) X ) y ) Y x y X X )1, SC = = = = = = = = __ = Btu/hr 41.0 32 0.256 336 32.7 32 0.30 315 32.7 32 0.30 315 32.7 32) 0.223 233 32.7 32) 0.223 233 20.0 32) 0.256 164 3.3 73) 0.301 204 32.7 73))-. 0.223 531 42.1 73))@ 0.256 787 17.5 73 0.223 284 Sched. Page Total 3 402 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 1,837 x 0.500 Watts/sqft x 3.413 Btu.,iMaft = 3,135 Occupants 1.00 X 1,837 x 250 Btuh/occ. 1 200 sgfffocc. = 2,296 Receptacle 1.00 x 1,837 x 1.500 Watts/sqft x 3.413 Btu;1/VVatt = 9,405 Process 1.00 X 1,837 x .. 0.000 Watts/s�591 gft x 3.41 Btuh/Watt = 0 Infiltration: �seh '�0 x Airs }x x ceilin x 1 / 60] I �T 3?J = Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 45,961 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 837 x 200 Btuh/OCC. / 200 sgftrocc. = 1 837 Receptacle 1.00 X 1 837 x 0.000 Watts/sgft x 3.41 Btuh[Waft = 0 Process (� 1.00 x 1 837 x 0.000 Watts/sqft X 3.41 Btuh/Waft = 0 Infiltration: I1 1.00 x 1 4,8401 x 1 83 x 10.50 x 0.50 / 60] O.OG433 = 3 368 chedule Alr Latent Area Ceiling Height ACH _yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 5,205 LEnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 35 of 38 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Sonnenberg Residence 6/22/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Living Area 78°F 115°F 370F Conduction Area U -Value DETD 1 Btu/hr X X X X X X X x X X = X - X = X = X = X = X = X = X = 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr CsmntWdw A est ( 0.0 x 1 + 54.0 x 73)x 0.256 = 1,009 ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )_ _ ( x + x )s = ( x + x )x = ( X + X )— Sched. Page Total 1 oos Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,837 X 0.500 Watts/sgft x 3.41 BtuhlWatt = 3,135 Occupants 1.00 X 1,837 X 250 Btuh/OCC. / 200 sgf'Iocc. = 2,296 Receptacle 1.00 x 1,837 X 1.500 Watts/sgft x 3.413 BtuhMaft = 9,405 Process 1.00 x 1,837 x .. 0.000 Watts/sgft x 3.41 BtuhMatt = 0 Infiltration: ��0 x Airs X Area S3 x Ceiling � x ACH / 60] T1 B-4201 _ Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 45,9611 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 1 837 x 200 Btuh/Occ. I 200 sgft/occ. = 1 837 Receptacle 1.00 X 1 837 X 0.000 Watts/sgft X 3.41 Btuh/Watt = o Process I� 1.00 X 1 837 X 0.000 Watts/sgft X 3.41 BtuhlWaft = o Infiltration: I 1.00 x 4840 x 1 83 x 10.50 x 0.50 / 60] 1 0.03433 = 3 368 -Schedule Air Latent Area Ceiling Height ACH \yy' Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 5,205 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 36 of 38 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Sonnenberg Residence 6/22/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction ' Raise Raise. R-38 Roof R.; ' R-21 Wall W.; Kolbe & Kolbe Kolbe & Kolbe Area U -Value 225. X C 694. X 0 919.Q X 0 1,170.4 X 0 227. X 0 15.5 X 0 X x X Second Floor 78°F 115°F 37°F DETD1 X 27.0 X 0.0 X 56.0 X 35.6 X 37.0 X 37.0 X X X Btu/hr 226 0 1,314 2,359 3,697 258 1. Design Equivalent Temperature Difference (DETD) Page Total 7 854 I Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr CsmntWdw M (North) sm (North) FXdGISWdW P (Northeast) CsmntWdw L (East) CsmntWdw (J) (East) FxdGlsWdw P (Southeast) CsmntWdw O (Southeast) CsmntWdw O (Southeast) CsmntWdw O) CsmntWdw K (Southeast) South ( 0.0 x1 x x x x x x X x + + + + + + + + + + 8.0 x x x X X x x X x 15) x x x x x ) x 0.256 = = = = = = = = = 31 ( 0.0x 1 8.0X 15)x 0.256= 31 ( 0.0 1 19.2 48) 0.30 277 ( 0.0 1 16.0 73) 0.256 299 (-0.0 1 18.0 73) 0.256 336 ( 0.0 1 19.2 62)X 0.301 358 ( 0.0 1 10.0 62) 0.256 159 ( 0.0 1 10.0 62)X 0.256 159 ( 0.0 1 10.0 62)x 0.256 159 ( 0.0 1 9.0 32 0.256 74 Sched. Page Total 1 ase Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 919 x 0.500 Watts/sqft x 3.412 Btuih/Watt = 1,568 Occupants 1.00 X 919 X 250 Btuh/OCC. / 200 sgfJocc. = 1,149 Receptacle 1.00 x 919 x 1.500 Watts/sqft x 3.413 BtulhMatt = 4,705 Process 1.00 x 919 x 0.000 Watts/ssgft x 3.412 BttulhMatt = 0 Infiltration: �on�LO x - Air 7k x Area Ceiling x ACH.50 / 60] nr = Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,084 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 919 x 200 Btuh/occ. I 200 sgf!/occ. = 919 R, eceptacle 1.00 x 919 x 0.000 Wafts/sqft x 3.41 Btuh/Watt = 0 Process 1.00 x 919 x 0.000 Wafts/sqft x 3.41 Btu nfWatt = o Infiltration: F -1-001x Air Latent X Area 91 x Ceiling Height x 60] Schedule ACH 50 / -\W Fraction = 1 524 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,443 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:37 of 38 RESIDENTIAL ROOM COOLING LOAD SUMMARY ■ The Sonnenberg Residence 6/22/2005 Project Title Date ' Room Name Second Floor Design Indoor Dry Bulb Temperature: 780F ' Design Outdoor Dry Bulb Temperature: 115 0F Design Temperature Difference: 370F Conduction Area U -Value X 1. Design Equivalent Temperature Difference (DETD) Page Total I Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Btu/hr 0 Solar Gain Orientation Area SGF Area SGF Sc Btu/hr CsmntWdw K (South) (West) CsmntWdw M (West) CsmntWdw N (West) CsmntWdw (N) (West) CsmntWdw N (West) CsmntWdw M (West) CsmntWdw L (West) FrnchDr 7 (West) 1 16.0 ( 0.0 X1 X x x X X x x X x + + + + + + + + + + 9.0 X X X x x x X X X x 32) K ) K ) _( ) x x x x ) x )x 0.256 = = = = = = = = = = 74 ( 0.0 1 18.0 73 0.256 336 ( 0.0 1 16.0 73 0.256 299 ( 0.0 1 10.9 73 0.256 204 ( 0.0 1 10.9 73) 0.256 204 ( 0.0 1" 10.9 73) 0.256 204 ( 0.0 1" 8.0 73) 0.256 150 ( 0.0 1" 16.0 73 0.256 299 ( 0.0 1 15.5 73)x 0.223 252 ( Sched. Page Total 2 021 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 919 x 0.500 Watts/sgft x 3.41 BtuhlWaft = 1,568 Occupants 1.00 X 919 X 250 Btuh/occ. I 200 sgfJocc. = 1,149 Receptacle 1.00 x 919 x 1.500 Wafts/sgft x 3.413 Btuh/Waft = 4,705 ,Process 1.00 x 919 x .. 0.000 Wafts/sqft x 3.41 BtLahMaft = _ 0 Infiltration: l d i J x Airs Area 'x x Ceiling x ACH / 60] T 29061 _ Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,084 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 919 x 2001 Btuh/occ. / 200 sgft/occ. = 919 Receptacle 1.00 x 919 x 0.000 Watts/sqft X 3.41 Btuh/Watt = 0 Process 1.00 X 919 x 0.000 Wafts/sqft x 3.41 Btuh/Waft = o Infiltration: 1.00 X 4 840 X 91 X Height X 60] 0.03433 = 1 524 ehedule Air Latent Area Ceiling Height ACH --�W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,443 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 38 of 38