10-0496 (AR)P.O. BOX 1504
Tiht
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number: 10-00000496 Owner:
Property Address: 77182 CALLE FLORA MILLER ROBERT G & SHARON L
APN: 658-210-012- - - 838 SW 1ST AVE #210
Application description: ADDITION - RESIDENTIAL PORTLAND, OR 97204
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 69470
Contractor:
Applicant: Architect or Engineer: GOLDEN CONSTRUCTION INC, PAU
73710 FRED WARING DR STE 101
PALM DESERT, CA 92260
(760)776-4215
Lic. No.: 786919
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Busislid Professionals Code, and my License is in full force and effect.
License Clas B License No.: 786919
Date:, ntractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(�) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.l.
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 7/16/10
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 719000192
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so a o become subject to the workers' compensation laws of California,
and agree that, if I sh come subject to the workers' compensation provisions of Section
3700 the Labor ode, s orthwi omply with those provisions.
te. pplican
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that t e information is correct. 1 agree to comply with all
city and county ordinances and state laws relating to rldin co struction, and hereby authorize representatives
of this coun o enter upon the above-mentioned pe ty o spection 3
ate' Signature (Applicant or Ag t),
Application Number . . . . . 10-00000496
Structure Information 811SF CASITA/VB/RES-3/CLASS A -FR [ENG]
Other struct info . .
. . . CODE EDITION 2007/2008
# BEDROOMS
2.00
FLOOD ZONE NO
GARAGE SQ FTG
19.00
PATIO SQ FTG
185.00
----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
811.00
Permit . . . BUILDING PERMIT
Additional desc . .
Permit Fee . . . .
504.50 Plan Check Fee
327.93
Issue Date . . . .
Valuation . . . .
69470
Expiration Date . .
1/12/11
Qty Unit Charge
Per
Extension
BASE FEE
414.50
20.00 4.5000
----------------------------------------------------------------------------
THOU BLDG 50,001-100,000
90.00
Permit . . . ELECT - ADD/ALT/REM
Additional desc . .
Permit Fee . . . .
43.77 Plan Check Fee
10.94
Issue Date . . . .
Valuation . . . .
0
Expiration Date
1/12/11
Qty Unit Charge
Per
Extension
BASE FEE
15.00
811.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY
28.39
19.00 .0200
----------------------------------------------------------------------------
ELEC GARAGE OR NON-RESIDENTIAL
.38
Permit . . . MECHANICAL
Additional desc . .
INCL RELOCATION OF EXST EQUIP
Permit Fee . . . .
75.00 Plan Check Fee
18.75
Issue Date . . . .
Valuation . . . .
0
Expiration Date . .
1/12/11
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 9.0000
EA MECH FURNACE <=100K
9.00
1.00 4.5000
EA MECH VENT INST/ DUCT ALT
4.50
2.00 9.0000
EA MECH APPL REP/ALT/ADD
18.00
1.00 9.0000
EA MECH B/C <=3HP/100K BTU
9.00
3.00 6.5000
----------------------------------------------------------------------------
EA MECH VENT FAN
19.50
Permit . . . . . . PLUMBING
LQPERMIT
Application Number . . . . . 10-00000496
Permit . . . PLUMBING
Additional desc . .
Permit Fee . . . . 100.50 Plan Check Fee
25.13
Issue Date . . . . Valuation . . .
. 0
Expiration Date . . 1/12/11
Qty Unit Charge Per
Extension
BASE FEE
15.00
12.00 6.0000 EA PLB FIXTURE
72.00
1.00 7.5000 EA PLB WATER HEATER/VENT
7.50
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS
3.00
----------------------------------------------------------------------------
Special Notes and Comments
811SF (2) BEDROOM CASITA WITH 185 SF
PATIO COVER/VB/RES-3/CLASS A -FR [ENG]
LOW PITCHED ROOFS SHALL COMPLY WITH ESR
2015P AND RELOCATED MECHANICAL EQUIPMENT
SHALL MAINTAIN ALL REQUIRED CLEARANCES.
A SEPARATE PERMIT IS REQUIRED FOR BLOCK
WALLS. 2007/2008 CALIFORNIA BUILDING
CODES.
July 16, 2010 12:15:04 PM AORTEGA
----------------------------------------------------------------------------
Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473)
3.00
ENERGY REVIEW FEE
32.79
STRONG MOTION (SMI) - RES
6.95
Fee summary Charged Paid Credited
-------------------------------------
Due
--------------------
Permit Fee Total 723.77 .00 .00
723.77
Plan Check Total 382.75 .00 .00
382.75
Other Fee Total 42.74 .00 .00
42.74
Grand Total 1149.26 .00 .00
1149.26
LQPERMIT
Date 7/22/10
No. 30768
Owner Robert G. Miller
Address 77-182 Calle Flora
City La Quinta Zip 92253
Tract #
Type Detached Guest House
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
La Quinta, CA 92253
(760) 771-8515
APN #
Jurisdiction
Permit #
No. of Units
q�J��t�sc�o
BERMUDA DUNES r
RANCHO MIRAGE d
INDIAN WELLS
q4. PALM DESERT y
LA QUINTA
P INDIO y�
O
658-210-012
La Quinta
Lot # No. Street S.F. Lot # No. Street S.F.
Unit 1 77182 Calle Flora 811 Unit 6
Unit 2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.97 X 811 S.F. or $2,408.67 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By C/C-Sunrise Bank, Paul Golden Check No. 001668
Name on the check Telephone 760/776-4215
Funding Residential
By Dr. Sharon P. McGehee
Superintendent
Fee collected /exem ed by Patricia Barbuzza Payment Recd
$21408.67 <= .Over/Undsr
Signature '
NOTICE: Pursuant to Government Code Section 62 (d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
OCHOA DESIGN ASSOCIATES
DESIGN / SITE PLANNING
73-626 Highway 111
Palm Desert, CA 92260
(760) 773-6605 Fax (760) 773-6602
July 19, 2010
To: Building and Safety Dep.
78-495 Calle Tampico
La Quinta Ca. 92253
Re: Miller residence
77-182 Calle Flora
La Quinta Ca. 92253
Dear Plan Examiner:
Ochoa Design Associates
architecture/design/planning
Our office reviewed the Roof Truss Layout and Calculations prepared by Spates Fabricators. The truss layout
and calculations are in substantial compliance with structural design.
Do not hesi to to call our office, for any questions regarding this.
Thank u,
Juan Carlos Ochoa
Lic.# C-28502
73-626 Highway 111 Palm Desert, CA 92260 (760) 773-6605 Fax (760) 773-6602
E -Mail: ochoadesign@ochoadesign.com Website: www.ochoadesign.com
OAIA Member of the American Institute of Architects
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Miller Guest Suite
71-182 Calle Flora
La Quinta, CA 92253
Project Designer:
Ochoa Design Associates
73-626 Highway 111
Palm Desert, CA 92260
760-773-6605
Report Prepared by:
Scott DeVoe
BREEZE AIR CONDITIONING
75-145 St. Charles Place
Palm Desert, CA 92211
(760) 346-0855
e
EEFR EZEZONING INC. •
Omb mg
----_ CITY OF LA QUINTA
[ Job Number: BUILDING & SAFETY DEPT.
' APPROVED
JUL 0 2 2010 CONSTRUCTION
FOR CON NS O
�y Date:
DATE ear
6/28/2010
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
I
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 8
HVAC System Heating and Cooling Loads Summary 11
Room Load Summary 12
Room Heating Peak Loads 13
Room Cooling Peak Loads 15
EnergyPro 5.0 by EnergySoft Job Number. ID: User Number: 3665
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -IR
Project Name
Miller Guest Suite
Building Type ® Single Family ® Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/28/2010
Project Address
71-182 Calle Flora La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond, Floor Area
811
Addition
811
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
Roof Wood Framed Attic
R-38 811 Radiant Barrier New
Wall Wood Framed
R-19 1,308 New
Slab Unheated Slab -on -Grade
None 811 Perim = 130' New
FENESTRATION U-
Orientation Area Factor
Exterior
SHGC Overhang Sidefins Shades Status
Front (N) 48.0 0.340
0.25 7.0 none Bug Screen New
Front (N) 18.0 0.320
0.32 none none Bug Screen New
Rear (S) 50.0 0.290
0.27 none none Bug Screen
New
Right (VV) 5.0 0.290
0.27 none none Bug Screen New
Front (N) 48.0 0.340
0.25 7.0 none Bug Screen New
Left (E) 5.0 0.290
0.27 none none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE Split Air Conditioner 14.2 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location - R -Value Status
Guest Suites Ducted
Ducted Attic, Ceiling Ins, vented 6.0
New
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
EnergyPro 5.0 by EnergySoft User Number., 3665 RunCode: 2010-06-28T08:24:4 ID.
Pa e 3 of 16
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Miller Guest Suite
Building Type ® Single Family ® Addition Alone
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/28/2010
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The Roof R-38 Roof includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -413 form for each of the measures listed below for final to be given.
The Cooling System Lennox XC14/G60UHV (3 Ton) includes credit for a 12.2 EER Condenser A certified HERS rater must field verify the installation
of the correct Condenser.
The HVAC System Guest Suites incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
EnemvPro 5.0 by EnemySoft User Number- 3665 RunCode: 2010-06-28T08:24:4 ID: Pa e 4 of 16
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family m Addition Alone
Date
Miller Guest Suite
❑ Multi Family ❑ Existing+ Addition/Alteration
6/2612010
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 5.74 5.93 -0.19
Space Cooling 74.06 68.94 5.13
Fans 14.80 19.63 -4.83
Domestic Hot Water 0.00 0.00 0.00
Pumps 0.00 0.00 0.00
Totals 94.61 94.50 0.10
Percent Better Than Standard: 0.1%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 0.10 (N) 432 114
Fuel Available at Site: Natural Gas (E) 247 5
Raised Floor Area: 0 (S) 536 50
Slab on Grade Area: 811 (Vtq 268 5
Average Ceiling Height: 9.5 Roof 811 0
Fenestration Average U -Factor: 0.32 TOTAL: 174
Average SHGC: 0.26 Fenestration/CFA Ratio: 21.5
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company BREEZE AIR CONDITIONING
628/2010
Address 75-145 St. Charles Place Name Scott Devoe
City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone (760) 346-0855 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Ochoa Design Associates
Address 73-626 Highway 111 Name Juan Carlos Och
City/State/Zip Palm Desert, CA 92260 Phone 760-773-6605 Signed License # Date
Ene Pro 5.0 by EnemySoft User Number: 3665 RunCode: 2 01 0-0 6-28 708:24:4 /D: Pae 5 of 16
CERTIFICATE OF COMPLIANCE: Residential
Part 4 of 5 CF -1 R
Project Name
Miller Guest Suite
Building Type ® Single Family m Addition Alone
0 Multi Family O Existing+ Addition/Alteration
Date
6/28/2010
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
400
0.025 R-38
270
0 New 4.2.1-A21
Zone 1A
Wall
178
0.074 R-19
0
90 New 4.3.1-A5
Zone 1A
Wall
30
0.074 R-19
90
90 New 4.3.1-A5
Zone 1A
Wall
261
0.074 R-19
180
90 New 4.3.1-A5
Zone 1A
Wall
2131
0.074 R-19
2701
90 New 4.3.1-A5
Zone 1A
Slab
400
0.730 None
0
180 New 4.4.7-A1
Zone 1A
Roof
411
0.025 R-38
270
0 New 4.2.1-A21
Zone 1B
Wall
140
0.074 R-19
0
90 New 4.3.1-A5
Zone 1B
Wall
212
0.074 R-19
90
90 New 4.3.1-A5
Zone 1B
Wall
226
0.074 R-19
180
90 New 4.3.1-A5
Zone 1B
Wall
50
0.074 R-19
270
90 New 4.3.1-A5
Zone 1B
Slab
411
0.730 None
0
180 New 4.4.7-A1
Zone 1B
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor SHGC
Azm Status
Glazing Type
Location/Comments
1
Window
48.0 0.340 NFRC 0.25 NFRC 0 New
Jeld-Wen Clad Lo/E (SGD)
Zone 1A
2
Window
9.0 0.320 NFRC 0.32 NFRC 0 New
Jeld-Wen Clad Lo/E (Fixed)
Zone 1A
3
Window
5.0 0.290 NFRC 0.27 NFRC 180 New
Jeld-Wen Clad Lo/E(Awning)
Zone 1A
4
Window
20.0 0.290 NFRC 0.27 NFRC 180 New
Jeld--Wen Clad Lo/E (Awning)
Zone 1A
5
Window
5.0 0.290 NFRC 0.27 NFRC 270 New
Jeld-Wen Clad Lo/E (Awning)
Zone 1A
6
Window
48.0 0.340 NFRC 0.25 NFRC 0 New
Jeld-Wen Clad Lo/E (SGD)
Zone 1B
7
Window
9.0 0.320 NFRC 0.32 NFRC 0 New
Jeld-Wen Clad Lo/E (Fixed)
Zone 1B
8
Window
5.0 0.290 NFRC 0.27 NFRC 90 New
Jeld-Wen Clad Lo/E (Awning)
Zone 1B
9
Window
5.0 0.290 NFRC 0.27 NFRC 180 New
Jeld-Wen Clad Lo/E (Awning)
Zone 1B
10
Window
20.0 0.290 NFRC 0.27 NFRC 180 New
Jeld-Wen Clad Lo/E (Awning)
Zone 1B
i T-
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC Hot Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len H t Dist Len H t
1
Bug Screen
0.76 8.0 6.0 7.0 0.1
7.0 7.0
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76 8.0 6.0 7.0 0.1
7.0 7.0
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
EnergyPro
5.0 by EnergySoft User Number.- 3665
RunCode: 2010-06-28T08:24:4 ID:
Page 6 of 16
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF -1 R
Project Name
Miller Guest Suite
Building Type ® Single Family ® Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1612812010
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existinq Altered Removed Volume Year Built
Guest Suites Guest Suite 1
400
3,800
Guest Suite 2
411
3,905
Totals 8111 0 01 0
HVAC SYSTEMS
System Name Oty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Guest Suites 1 Central Furnace
80% AFUE Split Air Conditioner 14.2 SEER Setback
New
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
Guest Suites Ducted
Ducted Attic, Ceiling Ins, vented 6.0
m New
WATER HEATING SYSTEMS
S stem Name Oty.
Type
Distribution
Rated
Input
(Btu h)
Tank
Cap.
al
Energy Standby
Factor Loss or
or RE Pilot
Ext.
Tank
Insul. R-
Value
Status
CEC Standard
MULTI -FAMILY WATER HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
E
E
zt� m
w a-
Hot Water Piping Length
ff
o
v
¢ —
System Name
Pipe
Lencith
Pipe
Diameter
Insul.
Thick.
Qty. HP
Plenum Outside Buried
❑
❑
❑
❑
❑
❑
❑
❑
EnemyPro 5.0 by EnemySoft User Number: 3665
RunCode: 2010-06-28708:24:4 ID:
Pae 7 of 16
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Miller Guest Suite
Date
6/28/2010
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (") below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-13.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
1500)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro5.0 by EnergySoft User Number: 3665 RunCode: 2010-06-28708:24:44 ID: Page 8 of 16
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Miller Guest Suite
1612812010
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dam ers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Ouality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 f12 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.0 by EnergySoft User Number: 3665 RunCode: 2010-06-28708:24:44 ID: Page 9 of 16
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R
Project Name
Date
Miller Guest Suite
1 6/28/2010
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual-
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPM 5.0 by EnergySoR User Number: 3665 RunCode: 2010-06-28708:24:44 ID: Page 10 of 16
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Miller Guest Suite
Date
6/28/2010
System Name
Guest Suites
Floor Area
811
ENGINEERING CHECKS
SYSTEM LOAD
Number of S stems
1
COIL
CFM
Total Room Loads 737
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 400
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
Sensible
12,682
0
1,051
0
16,677
0
1,051
1 31,461
PEAK COIL HTG.
PEAK
Heating System
Latent CFM
Sensible
Output perSystem 54,000
1,708 669
17,087
Total Output Btuh 54,000
Output Btuh/s ft 66.6
1,268
Cooling System
0
Output perSystem 33,800
8,082 400
22,565
Total Output Btuh 33,800
9,791
0
Total Output (Tons) 2.8
1,268
Total Output Btuh/s ft 41.7
Total Output s ftfron 287.9
1 42,187
Air System
CFM perSystem
1,200
HVAC EQUIPMENT SELECTION
Airflow(cfm)
1,200
Lennox XC14/G60UHV (3 Ton)
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
31,105
31,105
0 54,000
0 54,000
Aug 3 PM I Jan 1 AM
Airflow cfm/s ft 1.48
Airflow cfmrron 426.0
Outside Air % 33.3%
Outside Air cfm/s ft 0.49
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF 61 OF
Outside Air
400 cfm Supply Fan
1,200 cfm
79 OF
61 OF 105 OF
Heating Coil
104 OF
ROOM
80 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 86/67°F 86/67°F 55/54°F
Outside Air -4 r
400 cfm Supply Fan Cooling Coil
1,200 cfm
73/61 OF
4 No- 4 1 1 1 13.4
E
56 / 54 OF
51.7% ROOM
72 / 60 OF
EnergyPro5.0 by EnergySoft
User Number: 3665 RunCode: 2010-08-28708:24:44
ID:
Page 11 of 16
ROOM LOAD SUMMARY
Project Name Date
Miller Guest Suite 6/28/2010
System Name Floor Area
Guest Suites 811
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Zone 1A Guest Suite 1 1 370 6,365 848 370 6,365 848 330 8,430
Zone 1B Guest Suite 2 1 3671 6,317 860 367 6,317 8601 339 8,656
PAGE TOTAL
TOTAL'
737
12,682
1,708
669
17,087
737
12,682
1,708
669
17,087
Total includes ventilation load for zonal systems.
EnerqyPro5.0 by EnemySoft User Number: 3665 RunCode: 2010-06-28T08:24:4 ID: Pae 12 of 16
ROOM HEATING PEAK LOADS
Project Name
Miller Guest Suite
Date
6/28/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Guest Suite 1
Floor Area 400.0 ft2
Indoor Dry Bulb Temperature 80 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area U -Value AT *F
400.0 X 0.0250 X 54 =
681.3 X 0.0740 X 54 =
48.0 X 0.3400 X 54 =
9.0 X 0.3200 X 54 =
30.0 X 0.2900 X 54 =
perim = 60.0 X 0.7300 X 54 a
X X
X X =
X X
X X =
X X =
X X =
X X =
X X =
X X =
X X
X X =
X X =
X X =
X X
X X =
X X =
X X =
X X
X X =
X X
X X =
X X =
X X =
X X =
X X =
through an interior surface to another room Page Total
)( 400 X 9.50 X 0.356 /60] X
Area Ceiling Height ACH AT
Btu/hr
R-38 Roof
540
R-19 Wall
2,722
Jeld-Wen Clad Lo/E (SGD)
881
Jeld-Wen Clad WE (Fixed)
156
Jeld-Wen Clad WE (Awning)
470
Slab -On -Grade
2,365
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 )( 1.064
Schedule Air Sensible
Fraction
7,134
TOTAL HOURLY HEAT LOSS FOR ROOM 8,430
Energ Pro 5.0 by EnergySoft User Number.- 3665 RunCode: 2010-06-28T08:24:4 ID: Pae 13 of 16
ROOM HEATING PEAK LOADS
Project Name
Miller Guest Suite
Date
6/28/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Guest Suite 2
Floor Area 411.0 ftz
Indoor Dry Bulb Temperature 80 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value AT *F
X 0.0250 X 54 c
X 0.0740 X 54 c
X 0.3400 X 54 =
X 0,3200 X 54 =
X 0.2900 X 54 =
X 0.7300 X 54 =
X X
X X =
X X =
X X =
X X
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
to another room Page Total
9.50 X 0.356 /60] X �
Ceiling Height ACH AT
Btu/hr
R-38 Roof
411.0
555
R-19 Wall
626.5
2,503
Jeld-Wen Clad Lo/E (SGD)
48.0
881
Jeld-Wen Clad LWE (Fixed)
9.0
156
Jeld-Wen Clad Lo/E (Awning)
30.0
470
Slab -On -Grade
perim = 70.0
2, 759
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 411 X
Area
7,324
TOTAL HOURLY HEAT LOSS FOR ROOM 8,656
EnergyPro 5.0 by Energ Soft User Number: 3665 RunCode: 2010.06-28T08:24:4 ID: Pae 14 of 16
S . Y
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Miller Guest Suite
1 6/28/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Guest Suite 1
Outdoor Dry Bulb Temperature
112 OF
Floor Area 400.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 72 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof (Vtq 400.0 X 0.0250
X
56.0 =
560
R-19 Wall (N) 178.0 X 0.0740
X
23.0 =
303
R-19 Wall (E) 30.0 X 0.0740
X
33.0 =
73
R-19 Wall (S) 260.5 X 0.0740
X
26.0 =
501
R-19 Wall (WJ 212.8 X 0.0740
X
33.0 =
520
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
1,957
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF Area
GLF
Btu/hr
SIdgGIsOr (1) (N) 0.0 X 16.1 +
48.0
X 16.1 =
772
FxWdw (A) (N) 0.0 X 18.3 +
9.0
X 18.3 =
164
AwnWdw (8) (S) 0.0 X 15.8 +
5.0
X 15.9 =
79
AwnWdw (C) (S) 0.0 X 15.8 +
20.0
X 15.9 =
318
AwnWdw (8) (W) 0.0 X 15.8 +
5.0
X 31.8 =
159
X +
X -
X +
X -
X +
X -
X +
X -
Page Total
1,492
Internal Gain
Btu/hr
Occupants 2.0 Occupants X 230
Btuh/occ.
=
460
Equipment 1.0 Dwelling Unit X 1,600
Btu
Infiltration: 1.064 X 0.92 X 21.89 X 40 =
856
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
6,365
Latent Gain
Btu/hr
Occupants 2.0 Occupants X 200
Btuh/occ.
=
400
Infiltration: 4,771 X 0.92 X 21.89 X 0.00467 =
448
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
848
EnerqvPmo 5.0 by Ene Soft User Number: 3665 RunCode: 2010-06-28T08:24:4 ID:
Pae 15 of 16
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Miller Guest Suite
6/28/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Guest Suite 2
Outdoor Dry Bulb Temperature
112 OF
Floor Area 411.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 72 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
R-36 Roof (IM 411.0 X 0.0250
X
56.0 =
575
R-19 Wall (N) 139.5 X 0.0740
X
23.0 =
237
R-19 Wall (E) 211.5 X 0.0740
X
33.0 a
516
R-19 Wall (S) 225.5 X 0.0740
X
26.0 =
434
R-19 Wall (IAS 50.0 X 0.0740
X
33.0 =
122
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
1,885
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF Area
GLF
Btu/hr
SldgGISDr (1) (N) 0.0 X 16.1 +
48.0
X 16.1 =
772
FxWdw (A) (N) 0.0 X 18.3 +
9.0
X 18.3 =
164
Awn Wdw (B) (E) 0.0 X 15.8 +
5'0
X 31.8 =
159
Awn Wdw (B) (S) 0.0 X 15.8 +
5.0
X 15.9 =
79
AwnWdw (C) (S) 0.0 X 15.8 +
20.0
X 15.9 =
318
X +
X -
X +
X -
X +
X -
X +
X -
Page Total
1,492
Internal Gain
Btu/hr
Occupants 2.0 Occupants X 230
Btuh/occ.
=LA1,600
Equipment 1.0 Dwelling Unit X 1,600
Btu
=
Infiltration: 1.064 X 0.92 X 22.49 X 40 =
879
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
6,317
Latent Gain
Btu/hr
Occupants 2.0 Occupants X 200
Btuh/occ.
=1
400
Infiltration: 4,771 X 0.92 X 22.49 X 0.00467 =
460
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
860
Ene Pro 5.0 by Ene Soft User Number: 3665 RunCode: 2010-06-28T08:24:4 ID:
Pae 16 of 16