Loading...
10-0496 (AR)P.O. BOX 1504 Tiht 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 10-00000496 Owner: Property Address: 77182 CALLE FLORA MILLER ROBERT G & SHARON L APN: 658-210-012- - - 838 SW 1ST AVE #210 Application description: ADDITION - RESIDENTIAL PORTLAND, OR 97204 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 69470 Contractor: Applicant: Architect or Engineer: GOLDEN CONSTRUCTION INC, PAU 73710 FRED WARING DR STE 101 PALM DESERT, CA 92260 (760)776-4215 Lic. No.: 786919 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Busislid Professionals Code, and my License is in full force and effect. License Clas B License No.: 786919 Date:, ntractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (�) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.l. (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/16/10 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 719000192 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so a o become subject to the workers' compensation laws of California, and agree that, if I sh come subject to the workers' compensation provisions of Section 3700 the Labor ode, s orthwi omply with those provisions. te. pplican WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that t e information is correct. 1 agree to comply with all city and county ordinances and state laws relating to rldin co struction, and hereby authorize representatives of this coun o enter upon the above-mentioned pe ty o spection 3 ate' Signature (Applicant or Ag t), Application Number . . . . . 10-00000496 Structure Information 811SF CASITA/VB/RES-3/CLASS A -FR [ENG] Other struct info . . . . . CODE EDITION 2007/2008 # BEDROOMS 2.00 FLOOD ZONE NO GARAGE SQ FTG 19.00 PATIO SQ FTG 185.00 ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 811.00 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 504.50 Plan Check Fee 327.93 Issue Date . . . . Valuation . . . . 69470 Expiration Date . . 1/12/11 Qty Unit Charge Per Extension BASE FEE 414.50 20.00 4.5000 ---------------------------------------------------------------------------- THOU BLDG 50,001-100,000 90.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . . 43.77 Plan Check Fee 10.94 Issue Date . . . . Valuation . . . . 0 Expiration Date 1/12/11 Qty Unit Charge Per Extension BASE FEE 15.00 811.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 28.39 19.00 .0200 ---------------------------------------------------------------------------- ELEC GARAGE OR NON-RESIDENTIAL .38 Permit . . . MECHANICAL Additional desc . . INCL RELOCATION OF EXST EQUIP Permit Fee . . . . 75.00 Plan Check Fee 18.75 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/12/11 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 2.00 9.0000 EA MECH APPL REP/ALT/ADD 18.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 3.00 6.5000 ---------------------------------------------------------------------------- EA MECH VENT FAN 19.50 Permit . . . . . . PLUMBING LQPERMIT Application Number . . . . . 10-00000496 Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 100.50 Plan Check Fee 25.13 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/12/11 Qty Unit Charge Per Extension BASE FEE 15.00 12.00 6.0000 EA PLB FIXTURE 72.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ---------------------------------------------------------------------------- Special Notes and Comments 811SF (2) BEDROOM CASITA WITH 185 SF PATIO COVER/VB/RES-3/CLASS A -FR [ENG] LOW PITCHED ROOFS SHALL COMPLY WITH ESR 2015P AND RELOCATED MECHANICAL EQUIPMENT SHALL MAINTAIN ALL REQUIRED CLEARANCES. A SEPARATE PERMIT IS REQUIRED FOR BLOCK WALLS. 2007/2008 CALIFORNIA BUILDING CODES. July 16, 2010 12:15:04 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 3.00 ENERGY REVIEW FEE 32.79 STRONG MOTION (SMI) - RES 6.95 Fee summary Charged Paid Credited ------------------------------------- Due -------------------- Permit Fee Total 723.77 .00 .00 723.77 Plan Check Total 382.75 .00 .00 382.75 Other Fee Total 42.74 .00 .00 42.74 Grand Total 1149.26 .00 .00 1149.26 LQPERMIT Date 7/22/10 No. 30768 Owner Robert G. Miller Address 77-182 Calle Flora City La Quinta Zip 92253 Tract # Type Detached Guest House CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # No. of Units q�J��t�sc�o BERMUDA DUNES r RANCHO MIRAGE d INDIAN WELLS q4. PALM DESERT y LA QUINTA P INDIO y� O 658-210-012 La Quinta Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 77182 Calle Flora 811 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.97 X 811 S.F. or $2,408.67 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By C/C-Sunrise Bank, Paul Golden Check No. 001668 Name on the check Telephone 760/776-4215 Funding Residential By Dr. Sharon P. McGehee Superintendent Fee collected /exem ed by Patricia Barbuzza Payment Recd $21408.67 <= .Over/Undsr Signature ' NOTICE: Pursuant to Government Code Section 62 (d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting OCHOA DESIGN ASSOCIATES DESIGN / SITE PLANNING 73-626 Highway 111 Palm Desert, CA 92260 (760) 773-6605 Fax (760) 773-6602 July 19, 2010 To: Building and Safety Dep. 78-495 Calle Tampico La Quinta Ca. 92253 Re: Miller residence 77-182 Calle Flora La Quinta Ca. 92253 Dear Plan Examiner: Ochoa Design Associates architecture/design/planning Our office reviewed the Roof Truss Layout and Calculations prepared by Spates Fabricators. The truss layout and calculations are in substantial compliance with structural design. Do not hesi to to call our office, for any questions regarding this. Thank u, Juan Carlos Ochoa Lic.# C-28502 73-626 Highway 111 Palm Desert, CA 92260 (760) 773-6605 Fax (760) 773-6602 E -Mail: ochoadesign@ochoadesign.com Website: www.ochoadesign.com OAIA Member of the American Institute of Architects BUILDING ENERGY ANALYSIS REPORT PROJECT: Miller Guest Suite 71-182 Calle Flora La Quinta, CA 92253 Project Designer: Ochoa Design Associates 73-626 Highway 111 Palm Desert, CA 92260 760-773-6605 Report Prepared by: Scott DeVoe BREEZE AIR CONDITIONING 75-145 St. Charles Place Palm Desert, CA 92211 (760) 346-0855 e EEFR EZEZONING INC. • Omb mg ----_ CITY OF LA QUINTA [ Job Number: BUILDING & SAFETY DEPT. ' APPROVED JUL 0 2 2010 CONSTRUCTION FOR CON NS O �y Date: DATE ear 6/28/2010 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. I TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 8 HVAC System Heating and Cooling Loads Summary 11 Room Load Summary 12 Room Heating Peak Loads 13 Room Cooling Peak Loads 15 EnergyPro 5.0 by EnergySoft Job Number. ID: User Number: 3665 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -IR Project Name Miller Guest Suite Building Type ® Single Family ® Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/28/2010 Project Address 71-182 Calle Flora La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond, Floor Area 811 Addition 811 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 811 Radiant Barrier New Wall Wood Framed R-19 1,308 New Slab Unheated Slab -on -Grade None 811 Perim = 130' New FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Front (N) 48.0 0.340 0.25 7.0 none Bug Screen New Front (N) 18.0 0.320 0.32 none none Bug Screen New Rear (S) 50.0 0.290 0.27 none none Bug Screen New Right (VV) 5.0 0.290 0.27 none none Bug Screen New Front (N) 48.0 0.340 0.25 7.0 none Bug Screen New Left (E) 5.0 0.290 0.27 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.2 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location - R -Value Status Guest Suites Ducted Ducted Attic, Ceiling Ins, vented 6.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.0 by EnergySoft User Number., 3665 RunCode: 2010-06-28T08:24:4 ID. Pa e 3 of 16 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Miller Guest Suite Building Type ® Single Family ® Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/28/2010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -413 form for each of the measures listed below for final to be given. The Cooling System Lennox XC14/G60UHV (3 Ton) includes credit for a 12.2 EER Condenser A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System Guest Suites incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnemvPro 5.0 by EnemySoft User Number- 3665 RunCode: 2010-06-28T08:24:4 ID: Pa e 4 of 16 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family m Addition Alone Date Miller Guest Suite ❑ Multi Family ❑ Existing+ Addition/Alteration 6/2612010 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 5.74 5.93 -0.19 Space Cooling 74.06 68.94 5.13 Fans 14.80 19.63 -4.83 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 94.61 94.50 0.10 Percent Better Than Standard: 0.1% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 0.10 (N) 432 114 Fuel Available at Site: Natural Gas (E) 247 5 Raised Floor Area: 0 (S) 536 50 Slab on Grade Area: 811 (Vtq 268 5 Average Ceiling Height: 9.5 Roof 811 0 Fenestration Average U -Factor: 0.32 TOTAL: 174 Average SHGC: 0.26 Fenestration/CFA Ratio: 21.5 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company BREEZE AIR CONDITIONING 628/2010 Address 75-145 St. Charles Place Name Scott Devoe City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone (760) 346-0855 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Ochoa Design Associates Address 73-626 Highway 111 Name Juan Carlos Och City/State/Zip Palm Desert, CA 92260 Phone 760-773-6605 Signed License # Date Ene Pro 5.0 by EnemySoft User Number: 3665 RunCode: 2 01 0-0 6-28 708:24:4 /D: Pae 5 of 16 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Miller Guest Suite Building Type ® Single Family m Addition Alone 0 Multi Family O Existing+ Addition/Alteration Date 6/28/2010 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 400 0.025 R-38 270 0 New 4.2.1-A21 Zone 1A Wall 178 0.074 R-19 0 90 New 4.3.1-A5 Zone 1A Wall 30 0.074 R-19 90 90 New 4.3.1-A5 Zone 1A Wall 261 0.074 R-19 180 90 New 4.3.1-A5 Zone 1A Wall 2131 0.074 R-19 2701 90 New 4.3.1-A5 Zone 1A Slab 400 0.730 None 0 180 New 4.4.7-A1 Zone 1A Roof 411 0.025 R-38 270 0 New 4.2.1-A21 Zone 1B Wall 140 0.074 R-19 0 90 New 4.3.1-A5 Zone 1B Wall 212 0.074 R-19 90 90 New 4.3.1-A5 Zone 1B Wall 226 0.074 R-19 180 90 New 4.3.1-A5 Zone 1B Wall 50 0.074 R-19 270 90 New 4.3.1-A5 Zone 1B Slab 411 0.730 None 0 180 New 4.4.7-A1 Zone 1B FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 48.0 0.340 NFRC 0.25 NFRC 0 New Jeld-Wen Clad Lo/E (SGD) Zone 1A 2 Window 9.0 0.320 NFRC 0.32 NFRC 0 New Jeld-Wen Clad Lo/E (Fixed) Zone 1A 3 Window 5.0 0.290 NFRC 0.27 NFRC 180 New Jeld-Wen Clad Lo/E(Awning) Zone 1A 4 Window 20.0 0.290 NFRC 0.27 NFRC 180 New Jeld--Wen Clad Lo/E (Awning) Zone 1A 5 Window 5.0 0.290 NFRC 0.27 NFRC 270 New Jeld-Wen Clad Lo/E (Awning) Zone 1A 6 Window 48.0 0.340 NFRC 0.25 NFRC 0 New Jeld-Wen Clad Lo/E (SGD) Zone 1B 7 Window 9.0 0.320 NFRC 0.32 NFRC 0 New Jeld-Wen Clad Lo/E (Fixed) Zone 1B 8 Window 5.0 0.290 NFRC 0.27 NFRC 90 New Jeld-Wen Clad Lo/E (Awning) Zone 1B 9 Window 5.0 0.290 NFRC 0.27 NFRC 180 New Jeld-Wen Clad Lo/E (Awning) Zone 1B 10 Window 20.0 0.290 NFRC 0.27 NFRC 180 New Jeld-Wen Clad Lo/E (Awning) Zone 1B i T- (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Hot Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 8.0 6.0 7.0 0.1 7.0 7.0 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 8.0 6.0 7.0 0.1 7.0 7.0 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 EnergyPro 5.0 by EnergySoft User Number.- 3665 RunCode: 2010-06-28T08:24:4 ID: Page 6 of 16 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Miller Guest Suite Building Type ® Single Family ® Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1612812010 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built Guest Suites Guest Suite 1 400 3,800 Guest Suite 2 411 3,905 Totals 8111 0 01 0 HVAC SYSTEMS System Name Oty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Guest Suites 1 Central Furnace 80% AFUE Split Air Conditioner 14.2 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Guest Suites Ducted Ducted Attic, Ceiling Ins, vented 6.0 m New WATER HEATING SYSTEMS S stem Name Oty. Type Distribution Rated Input (Btu h) Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E E zt� m w a- Hot Water Piping Length ff o v ¢ — System Name Pipe Lencith Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ EnemyPro 5.0 by EnemySoft User Number: 3665 RunCode: 2010-06-28708:24:4 ID: Pae 7 of 16 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Miller Guest Suite Date 6/28/2010 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (") below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 1500)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro5.0 by EnergySoft User Number: 3665 RunCode: 2010-06-28708:24:44 ID: Page 8 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Miller Guest Suite 1612812010 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dam ers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Ouality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 f12 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.0 by EnergySoft User Number: 3665 RunCode: 2010-06-28708:24:44 ID: Page 9 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Miller Guest Suite 1 6/28/2010 §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual- on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPM 5.0 by EnergySoR User Number: 3665 RunCode: 2010-06-28708:24:44 ID: Page 10 of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Miller Guest Suite Date 6/28/2010 System Name Guest Suites Floor Area 811 ENGINEERING CHECKS SYSTEM LOAD Number of S stems 1 COIL CFM Total Room Loads 737 Return Vented Lighting Return Air Ducts Return Fan Ventilation 400 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING Sensible 12,682 0 1,051 0 16,677 0 1,051 1 31,461 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 54,000 1,708 669 17,087 Total Output Btuh 54,000 Output Btuh/s ft 66.6 1,268 Cooling System 0 Output perSystem 33,800 8,082 400 22,565 Total Output Btuh 33,800 9,791 0 Total Output (Tons) 2.8 1,268 Total Output Btuh/s ft 41.7 Total Output s ftfron 287.9 1 42,187 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow(cfm) 1,200 Lennox XC14/G60UHV (3 Ton) Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 31,105 31,105 0 54,000 0 54,000 Aug 3 PM I Jan 1 AM Airflow cfm/s ft 1.48 Airflow cfmrron 426.0 Outside Air % 33.3% Outside Air cfm/s ft 0.49 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 61 OF Outside Air 400 cfm Supply Fan 1,200 cfm 79 OF 61 OF 105 OF Heating Coil 104 OF ROOM 80 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 86/67°F 86/67°F 55/54°F Outside Air -4 r 400 cfm Supply Fan Cooling Coil 1,200 cfm 73/61 OF 4 No- 4 1 1 1 13.4 E 56 / 54 OF 51.7% ROOM 72 / 60 OF EnergyPro5.0 by EnergySoft User Number: 3665 RunCode: 2010-08-28708:24:44 ID: Page 11 of 16 ROOM LOAD SUMMARY Project Name Date Miller Guest Suite 6/28/2010 System Name Floor Area Guest Suites 811 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone 1A Guest Suite 1 1 370 6,365 848 370 6,365 848 330 8,430 Zone 1B Guest Suite 2 1 3671 6,317 860 367 6,317 8601 339 8,656 PAGE TOTAL TOTAL' 737 12,682 1,708 669 17,087 737 12,682 1,708 669 17,087 Total includes ventilation load for zonal systems. EnerqyPro5.0 by EnemySoft User Number: 3665 RunCode: 2010-06-28T08:24:4 ID: Pae 12 of 16 ROOM HEATING PEAK LOADS Project Name Miller Guest Suite Date 6/28/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Suite 1 Floor Area 400.0 ft2 Indoor Dry Bulb Temperature 80 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value AT *F 400.0 X 0.0250 X 54 = 681.3 X 0.0740 X 54 = 48.0 X 0.3400 X 54 = 9.0 X 0.3200 X 54 = 30.0 X 0.2900 X 54 = perim = 60.0 X 0.7300 X 54 a X X X X = X X X X = X X = X X = X X = X X = X X = X X X X = X X = X X = X X X X = X X = X X = X X X X = X X X X = X X = X X = X X = X X = through an interior surface to another room Page Total )( 400 X 9.50 X 0.356 /60] X Area Ceiling Height ACH AT Btu/hr R-38 Roof 540 R-19 Wall 2,722 Jeld-Wen Clad Lo/E (SGD) 881 Jeld-Wen Clad WE (Fixed) 156 Jeld-Wen Clad WE (Awning) 470 Slab -On -Grade 2,365 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 )( 1.064 Schedule Air Sensible Fraction 7,134 TOTAL HOURLY HEAT LOSS FOR ROOM 8,430 Energ Pro 5.0 by EnergySoft User Number.- 3665 RunCode: 2010-06-28T08:24:4 ID: Pae 13 of 16 ROOM HEATING PEAK LOADS Project Name Miller Guest Suite Date 6/28/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Suite 2 Floor Area 411.0 ftz Indoor Dry Bulb Temperature 80 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value AT *F X 0.0250 X 54 c X 0.0740 X 54 c X 0.3400 X 54 = X 0,3200 X 54 = X 0.2900 X 54 = X 0.7300 X 54 = X X X X = X X = X X = X X X X = X X = X X = X X = X X = X X = X X = X X X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = to another room Page Total 9.50 X 0.356 /60] X � Ceiling Height ACH AT Btu/hr R-38 Roof 411.0 555 R-19 Wall 626.5 2,503 Jeld-Wen Clad Lo/E (SGD) 48.0 881 Jeld-Wen Clad LWE (Fixed) 9.0 156 Jeld-Wen Clad Lo/E (Awning) 30.0 470 Slab -On -Grade perim = 70.0 2, 759 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 411 X Area 7,324 TOTAL HOURLY HEAT LOSS FOR ROOM 8,656 EnergyPro 5.0 by Energ Soft User Number: 3665 RunCode: 2010.06-28T08:24:4 ID: Pae 14 of 16 S . Y RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Miller Guest Suite 1 6/28/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Suite 1 Outdoor Dry Bulb Temperature 112 OF Floor Area 400.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof (Vtq 400.0 X 0.0250 X 56.0 = 560 R-19 Wall (N) 178.0 X 0.0740 X 23.0 = 303 R-19 Wall (E) 30.0 X 0.0740 X 33.0 = 73 R-19 Wall (S) 260.5 X 0.0740 X 26.0 = 501 R-19 Wall (WJ 212.8 X 0.0740 X 33.0 = 520 X X = X X = X X = X X = Page Total 1,957 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr SIdgGIsOr (1) (N) 0.0 X 16.1 + 48.0 X 16.1 = 772 FxWdw (A) (N) 0.0 X 18.3 + 9.0 X 18.3 = 164 AwnWdw (8) (S) 0.0 X 15.8 + 5.0 X 15.9 = 79 AwnWdw (C) (S) 0.0 X 15.8 + 20.0 X 15.9 = 318 AwnWdw (8) (W) 0.0 X 15.8 + 5.0 X 31.8 = 159 X + X - X + X - X + X - X + X - Page Total 1,492 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460 Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 0.92 X 21.89 X 40 = 856 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,365 Latent Gain Btu/hr Occupants 2.0 Occupants X 200 Btuh/occ. = 400 Infiltration: 4,771 X 0.92 X 21.89 X 0.00467 = 448 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 848 EnerqvPmo 5.0 by Ene Soft User Number: 3665 RunCode: 2010-06-28T08:24:4 ID: Pae 15 of 16 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Miller Guest Suite 6/28/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Suite 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 411.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-36 Roof (IM 411.0 X 0.0250 X 56.0 = 575 R-19 Wall (N) 139.5 X 0.0740 X 23.0 = 237 R-19 Wall (E) 211.5 X 0.0740 X 33.0 a 516 R-19 Wall (S) 225.5 X 0.0740 X 26.0 = 434 R-19 Wall (IAS 50.0 X 0.0740 X 33.0 = 122 X X = X X = X X = X X = Page Total 1,885 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr SldgGISDr (1) (N) 0.0 X 16.1 + 48.0 X 16.1 = 772 FxWdw (A) (N) 0.0 X 18.3 + 9.0 X 18.3 = 164 Awn Wdw (B) (E) 0.0 X 15.8 + 5'0 X 31.8 = 159 Awn Wdw (B) (S) 0.0 X 15.8 + 5.0 X 15.9 = 79 AwnWdw (C) (S) 0.0 X 15.8 + 20.0 X 15.9 = 318 X + X - X + X - X + X - X + X - Page Total 1,492 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. =LA1,600 Equipment 1.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 0.92 X 22.49 X 40 = 879 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,317 Latent Gain Btu/hr Occupants 2.0 Occupants X 200 Btuh/occ. =1 400 Infiltration: 4,771 X 0.92 X 22.49 X 0.00467 = 460 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 860 Ene Pro 5.0 by Ene Soft User Number: 3665 RunCode: 2010-06-28T08:24:4 ID: Pae 16 of 16