Andalusia TR 31681 (75 Series; Plans 4-6) Title 24REVISED Title 24 Energy Conservation Standards Compliance Report ANDALUSIA AT CORAL MOUNTAIN 75 SERIES ■PLANS LA QUINTA 4-5-6 I CITY OF LA QUINTA November 10, 2004 Y Job Nu, MOP2e4§f B-7Y DEPT. ! FOR CONSAJCTION ROVED Prepared F,or'A° CORAL OPTION I—, C P.O. BOX 1716 LA QUINTA, CA 92253 (760) 777-7747 Madlin ' s enterptises Catherine M. Madlin, Certified Energy Analyst Post Office Box 1443 • Palm Springs, CA 92263 760-322-5004 / 323-3644 (fax) E-mail: CMadlin@aol.com Ma 1d1in s enterpfises Catherine M. Madlin, Certified Energy Analyst . 760-322-5004 / 323-3644 (fax) ....... Title 24 Energy Conservation Standards Compliance Report This proposed project has been reviewed for compliance with the 2001 State of California Energy Conservation Standards, Title 24, by Madlin's Enterprises. The building design described in this compliance portfolio is in conformance with the standards as outlined in the attached compliance forms and documentation. r Date: November 10, 2004 Job Number: 24575B Owner's Name: Coral Option I, LLC. Project Designer: Pekarek-Crandell, Inc. Project Name: Andalusia at Coral Mountain - 75 Series Project Location: La Quinta Method of Compliance: Micropas V6.1 Certified Computer Program i V` Post Office Box 1443 • Palm Springs, Ca 92263 v Y Madlin ente fises Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) ...... . CNC;::<C��P��IET�T`'.>;: i:i':' :C ..........:.:...;L�11�i�:E::RE..�,iTitEME�I'I'�'.::>:::::< Job Name Andalusia at Coral Mountain - 75 Series Job No. / File No. 24575B Method of Compliance Micropas V6.1 Computer Simulation Insulation: Roof / Ceiling R-38 Batts Roof Radiant Barrier Required Insulation: Walls R-19 Batts + V EPS R-3.9 or Better R-19 Batts - Firewall House to Garage or Utility R-13 Batts - 2x4 Walls - Firewall Insulation: Floor - Slab on Grade Not Required ` Insulation: H.V.A.C. Ducts/Location/Testing R-4.2 / Attic / No Duct Testing Glazing U Value / Type: Fixed, Operable, DH, Case Glazing Solar Heat Gain Coefficient , 0.38, Dual Pane, Low E2, Any Frame Type 0.35 SHGC (NFRC Tested Values) Glazing U-Value / Type: French Drs or Std Patio Drs Glazing Solar Heat Gain Coefficient 0.38, Dual Pane, Low E2, Any Frame Type 0.35 SHGC (NFRC Tested Values) Glazing U-Value / Type: Large Patio Doors Glazing Solar Heat Gain Coefficient 0.40, Dual Pane, Low E2, Any Frame Type 0.40 SHGC (NFRC Tested Values) Glazing U-Value / Type: Entry Doors Glazing Solar Heat Gain Coefficient 0.50, Dual Pane, Low E2, Any Frame Type 0.50 SHGC (NFRC Tested Values) Glazing U-Value / Type: Skylights or Solar Tubes 1.72 Single Domed, Clear (CEC Default Value) Glazing Exterior Shading Overhangs as Shown on Plans Thermal Mass Square Footage & % Not Required H.V.A.C. System Type Gas Heating / Electric Cooling Units HVAC System Efficiencies (heating/cooling) 78% AFUE / 12.0 SEER with TX Valve Domestic Hot Water Heater (1) 75 Gallon Gas - All Models + (1) 30 Gallon Gas In Designated Guest Suites Energy Factor / Eff. / Standby Loss 0.78 RE or Better - 75 Gallon Units 0.58 EF or Better - 30 Gallon Units R12 Blanket on Tank Not Required Recirculating Pump for DHW Yes - 75 Gallon Systems Other Requirements Applicable Mandatory Measures • Post Office Box 1443 v Palm Springs, Ca 92263 v Madlin s enterprises Catherine M. Madlin, Certified Energy Analyst • 760-322-5004 / 323-3644 (fax) ... . o a o n o Madlin-'s enterprises Catherine M. Madlin, Certified Energy Analyst . 760-322-5004 / 323-3644 (fax) ... v .. Andalusia at Coral Mountain Series 75 - flan 4 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Project Title.......... ANDALUSIA.PLAN.4 Date..11/09/04 13.54:57 Project Address........ PLAN 4 ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date E Climate Zone. ..... 15------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-24575B1 Wth-CTZ15S92 Program -FORM CF-1R ! I User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------------------------------------------------------------------------------I ! GENERAL INFORMATION Conditioned Floor ------------------- Area..... 3933 sf i Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories.. ....... 1 Floor Construction Type.... Slab On Grade' ' Glazing Percentage......... 19.4 % of floor area Average Glazing U-factor... 0.4 Btu/hr-sf-F Average Glazing SHGC....... 0.38 Average Ceiling Height..... 10.9 ft T BUILDING SHELL INSULATION Component Frame ------------------------- Cavity Sheathing Total Assembly ! Type Type --------- R-value -------- R-value R-value U-factor Location/Comments Wall Wood R-17.8 ---------------------- ------------------------ R-3.9 R-21.7 0.051 i Wall Wood R-17.8 R-0 R-17.8 0.064 Door None R-0 R-0 R-0 0.330 RoofRadiant Wood R-11 R-27 R-38 0.025 S1abEdge None R-0 R-0 F2=0.760 SlabEdge i. None R-0 R-0 F2=0.510 FENESTRATION ------------ Area U- Interior Exterior Over- hang/ Orientation ---------- (sf) Factor SHGC Shading Shading Fins Window Back (S) ----- ------ 48.0 0.380 --------------------- 0.350 Standard -------------- Standard ----- Yes Door Right (W) 48.0 0.380 0.350 Standard Standard .Yes Door Back (S) 240.0 0.400 0.400 Standard Standard Yes Door Back (S) 48.0 0.380 0.350 Standard Standard Yes Door Back (S) 48.0 0.380 0.350 Standard Standard Yes Window Right (W) 4.0 0.380 0.350 Standard Standard None Window Right (W) 4.0 0.380 0.350 Standard Standard None Window Right (W) 9.0 0.380 0.350 Standard Standard None Window Right (W) 13.5 0.380 0.350 Standard Standard None Window Right (W) 9.0 0.380 0.350 Standard Standard None Window Right (W) 9.0 0.380 0.350 Standard Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Right (W) 4:5 0.380 0.350 Standard Standard None Window Right. (W) 4.5 0.380 0.350 Standard Standard None. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... ANDALUSIA.PLAN.4 Date..11/09/04 13:54:57 -----MICROPAS6 v6.01 File-24575B1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin s Enterprises Run -REVISED PERMIT CALC ----------------------------------------------------------------------- FENESTRATION ------------ Over- Area U- Interior Exterior hang/ Orientation --------- (sf) ----- Factor SHGC Shading Shading Fins - Window Front (N) 15.0 ------ 0.380 ------ 0.350 --------------- Standard -------------- Standard ----- None Door Left (E) 48.0 0.380 0.350 Standard Standard None Window Front (N) 4.5 0.380 0.350 Standard Standard None Window Front (N) 4.5 0.380 0.350 Standard Standard None Window Right (W) 12.5 0.380 0.350 Standard Standard None i Window Right (W) 12.5 0.380 0.350 Standard Standard None ! Window Left (E) 4.5 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Window Back (S) 12.5 0.380 0.350 Standard Standard None Window Back (S) 12.5 0.380 0.350 Standard Standard None Door Back (S) 24.0 0.380 0.350 Standard Standard None i Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Right (W) 23.4 0.380 0.350 Standard Standard None Window Front (N) 4.5 0.380 0.350 Standard Standard None Door Front (N) 48.0 0.500 0.500 Standard Standard None Window Left (E) 4.5 0..380 0.350 Standard Standard None Window Left (E) 20.0 0.380 0.350 Standard Standard None Equipment Type Furnace ACSplitTXV Furnace ACSplitTXV Minimum Efficiency 0.780 AFUE 12.00 SEER 0.780 AFUE 12.00 SEER SLAB SURFACES Area Slab Type (sf) Standard Slab 3429 Standard Slab 504 HVAC SYSTEMS ------------ Refrigerant Tested ACCA Charge and Duct Duct Duct Manual Airflow Location R-value Leakage D ----------------- n/a Attic ------- R-4.2 ------- No ------ No Yes Attic R-4.2 No No n/a Attic R-4.2 No No Yes Attic R-4.2 No No Thermostat Type Setback Setback Setback Setback CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF.-1R Project Title.......... ANDALUSIA.PLAN.4 Date..11/09/04 13:54:57 -----MICROPAS6 v6.01 File-24575B1 Wth-CTZ15S92 Program -FORM CF-lR User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC -------------------------------------------------------------------- WATER HEATING SYSTEMS ! Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value ------------------------------------------ -------------- ------ ---------- DHW 1 Large Gas Recirc/TimeTemp 1 n/a' 75 R-0 DHW 2 z Storage. Gas Standard 1 0.58 30 R- n/a t WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss Insulation Pilot System - Efficiency Input Fraction R-value Light ------------------ --------------- DHW1---------------------- Large 0.78 n/a 0.03 R-n/a 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** ( This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet.attic ventilation criteria. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) ! or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-1R Project Title.......... ANDALUSIA.PLAN.4 Date..11/09/04 13:54:57 -MICROPAS6v6.01 File-24575B1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin s Enterprises Run -REVISED PERMIT CALC ----- - --------------------------------------------------------------- REMARKS This revised calculation reflects updates/changes to glazing areas and types. The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The installing hvac contractor shall provide the required CF-6R with the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the HVAC system. The installed plumber shall provide the required CF-6R listing the water heater model number(s) and certified plumbing fixtures. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 5 CF-1R Project Title.......... ANDALUSIA.PLAN.4 Date..11/09/04 13.54.57 MICROPAS6 v6.01 File-24575B1 Wth-CTZ15S92 Program -FORM CF-1R -------_User#_MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------------------------------------ -------------------- ------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations. to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER .-Name.*.. Company. CORAL OPTION 1, LLC Address. P.O. BOX 1716 LA QUINTA, CA 92253. Phone... 760-777-7747 License. Signed.. 1j ( at ) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) 1 DOCUMENTATION AUTHOR Name.... CATHERINE M. MADLIN Company. Madlin's Enterprises Address. P.O. Box 1443 Palm Springs, CA 92262 Phone... 760-322-5004 Signed.. ( ate) Certified Energy Analyst Catherine M. Madlin NR 98-90-544 r r rr R 98-90-144 CADEC California Association of Building Energy Consultants COMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... ANDALUSIA.PLAN.4 Date..11/09/04 13.54.57 Project Address........ PLAN 4 ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone........... 15 Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-24575B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----- ----------------------------------------------------------- = MICROPAS6 ENERGY USE SUMMARY = -------------------------P-- = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) ------------------------ Design ---------- Design Margin = = Space Heating......... 4.32 ---------- 3.87 ---------- _ 0.45 = = Space Cooling.......... 38.81 32.73 6.08 = = Water Heating.......... 7.25 9.74 -2.49 = North Total 50.38 46.34 4.04 = = Space Heating.......... 4.32 4.33 -0.01 = = Space Cooling.......... 38.81 33.06 5.75 = = Water Heating.......... 7.25 9.74 -2.49 = East Total -------- 50.38 -------- 47.13 -------- 3.25 = Space Heating.......... 4.32 4.48 -0.16 = = Space Cooling.......... 38.81 32.79 6.02 = = Water Heating.......... 7.25 9.74 -2.49 = South Total -------- 50.38 -------- 47.01 -------- 3.37 = Space Heating.......... 4.32 3.82 0.50 = = Space Cooling.......... 38.81 33.60 521 = = Water - Heating...... .. 7.25 9.74 -2..49 = = West Total -------- 50.38 -------- 47.16 -------- _ 3.22 = _ *** Building complies ---------------- with Computer Performance GENERAL INFORMATION Conditioned Floor Area..... 3933 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 2 COMPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... ANDALUSIA.PLAN.4 _______________________________________________________ Date..11/09/04 13:54:57 MICROPAS6 v6.01 File-24575B1 Wth-CTZ15S92 Program -FORM C-2R --------User#-MP0207 ------------------------------------------------------------ User-Madlin's Enterprises Run -REVISED PERMIT CALC Conditioned Volume......... 42912 cf Slab -On -Grade Area......... 3933 sf Glazing Percentage......... 19.4 % of floor area Average Glazing U-factor... 0.4 Btu/hr-sf-F Average Glazing SHGC....... 0.38 Average Ceiling Height..... 10.9 ft BUILDING ZONE INFORMATION Floor ---------------------- # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage C- Zone Type (sf) -------------- ----- (cf) Units itioned Type (ft) (sf) Credit 1 1.ZONE ------- ------------ ------------------- -Residence 3429 37872 0.87 Yes Setback 2:0 Standard No 2.ZONE Residence 504 5040 0.13 Yes Setback 2.O Standard No OPAQUE SURFACES Area U- --------------- Insul Act Solar Form 3 Location/ Surface (sf) --------------- factor ----- R-val Azm Tilt Gains Reference Comments 1.ZONE ----- --- ---- - ----------------- ---------------- `. 1 Wall 414 0.051 21.7 0 90 Yes W.17.8.PW2X6 + 2 Wall 1075 0.051 21.7 90 90 Yes W.17.8.PW2X6 3 Wall 408 -0.051 21.7 180 90 Yes W.17.8.PW2X6 5 Wall 1023 0.051 21.7 270 90 Yes W.17.8.PW2X6 ' 7 Wall 305 0.064 17.8 0 90 No W.19.2X6FIRE 9 Wall 115 0.064 17.8 0 90 No W.19.2X6FIRE 13 Door 24 0.330 0 0 90 No None 14 RoofRadiant 3427 0.025 38 n/a 0 Yes R.38.2X4.24 2.ZONE 4 Wall 106 0.051 21.7 180 90 Yes W.17.8.PW2X6 6 wall 170 0.051 21.7 270 90 Yes W.17.8.PW2X6 8 Wall 508 0.064 17.8 0 90 No W.19.2X6FIRE 10 Wall 13 0.051 21.7 135 90 Yes W.17.8.PW2X6 11 Wall 120 0.051 21.7 225 90 Yes W.17.8.PW2X6 12 Wall 13 0.051 21.7 315 90 Yes W.17.8.PW2X6 15 RoofRadiant 504 0.025 38 n/a 0 Yes R.38.2X4.24 PERIMETER LOSSES Length ---------------- F2 Insul Solar Surface (ft) ------------ ------ Factor R-val Gains Location/Comments 1 1.ZONE -------- ------- ----- ---------------------- 16 S1abEdge 270 0.760 R-0 No 18 S1abEdge 33 0.510 R-0 No 2.ZONE 17 S1abEdge 50 0.760 R-0 No . 19 S1abEdge 51 0.510 R-0 No COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... ANDALUSIA.PLAN.4 Date..11/09/04 13:54:57 MICROPAS6 v6.01 File-24575B1 Wth-CTZ15S92 Program -FORM C-2R User#_MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC -------- ------------------------------------------------------------ Orientation ---------------------- 1.ZONE 1 Window Back (S) 2 Door Right (W) 3 Door Back (S) 4 Door Back (S) 5 Door Back (S) 6 Window Right (W) 7 Window Right (W) 8 Window Right (W) 9 Window Right (W) 10 Window Right (W) 11 Window Right (W) 12 Window Right (W) 13 Window Right (W) 14 Window Right (W) 15 Window Front (N) 16 Door Left (E) 17 Window Front (N) 18 Window Front (N) 19 Window Right (W) 20 Window Right (W) 21 Window Left (E) 22 Window Left (E) 23 Window Left (E) 24 Window Left (E) 25 Skylight Horz 26 Skylight Horz 32 Window Front (N) 33 Door Front (N) 34 Window Left (E) 35 Window Left (E) 2.ZONE 27 Window Back (S) 28 Window Back (S) 29 Door Back (S) 30 Window Right (W) 31 Window Right (W) FENESTRATIO N Act Exterior Shade Interior Shade Azm Tilt Type/SHGC Type/SHGC --- -------------------------------- 48.0 0.380 0.350 180 90 48.0 0.380 0.350 270 90 240.0 0.400 0.400 180 90 48.0 0.380 0.350 180 90 48.0 0.380 0.350 180 90 4.0 0.380 0.350 270 90 4.0 0.380 0.350 270 90 9.0 0.380 0.350 270 90 13.5 0.380 0.350 270 90 9.0 0.380 0.350 270 90 9.0 0.380 0.350 270 90 4.5 0.380 0.350 270 90 4.5 0.380 0.350 270 90 4.5 0.380 0.350 270 90 15.0 0.380 0.350 0 90 48.0 0.380 0.350 90 90 4.5 0.380 0.350 0 90 4.5 0.380 0.350 0 90 12.5 0.380 0.350 270 90 12.5 0.380 0.350 270 90 4.5 0.380 0.350 90 90 4.5 0.380 0.350 90 90 4.5 0.380 0.350 90 90 4.5 0.380 0.350 90 90 1.0 1.720 0.830 0 0 1.0 1.720 0.830 0 0 4.5 0.380 0.350 0 90 48.0 0.500 0.500 0 90 4.5 0.380 0.350 90 90 20.0 0.380 0.350 90 90 12.5 0.380 0.350 180 90 12.5 0.380 0.350 180 90 24.0 0.380 0.350 180 90 4.5 0.380 0.350 270 90 23.4 0.380 0.350 270 90 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 None/1 None/1 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 OVERHANGS AND SIDE FINS Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 None/1 None/1 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface (sf) ----- Wdth ----- Hgth ----- Dpth ---- Hght Ext Ext Ext Dpth Hght Ext Dpth Hght 1.ZONE ---- ---- ---- ---- ---- ---- _ ____ 1 Window 48.0 8 6 1 0 n/a n/a n/a n/a n/a n/a n/a n/a 2 Door 48.0 6 8 25.5 6 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 240.0 20 12 16.5 2 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 48.0 6 8 11 2 n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 48.0 6 8 11 2 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... ANDALUSIA.PLAN.4 Date..11/09/04 13:54:57 MICROPAS6 v6.01 File-24575B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------------------------------------------------------------------------------- SLAB SURFACES Area Slab Type (sf) ---------------- ------ 1.ZONE Standard Slab 3429 2.ZONE ' Standard Slab 504 HVAC SYSTEMS I------------ Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type Efficiency Airflow Location R-value Leakage D Eff -------------------------------------------------------------------- ---- 1.ZONE Furnace 0.780 AFUE n/a Attic R-4.2 No No 0.743 ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No 0.637 t 2.ZONE Furnace 0.780 AFUE n/a Attic R-4.2 No No 0.743 ACSplitTXV 12.00 SEER Yes Attic R-4.2 No' No 0.637 WATER HEATING SYSTEMS --------------------- Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value ------------------------------------------ -------------- ---------------- DHW 1 1 Large Gas Recirc/TimeTemp 1 n/a 75 R-0 DHW 2 2 Storage Gas Standard 1 0.58 30 R- n/a { WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R-value Light -------------------------------------------------------------------- DHW 1 1 Large 0.78 n/a 0.03 R-n/a 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed -to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** 1 This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. COMPUTER METHOD SUMMARY Page 5 C-2R Project Title.......... ANDALUSIA.PLAN.4 Date..11/09/04 13:54:57 -----MICROPAS6v601--File-24575B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin s Enterprises Run -REVISED PERMIT CALC - ---------------- ------------- ------- ----- ------- SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION -------------------------- *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** *** must be reported on the CF-6R installation certificate. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS This revised calculation reflects updates/changes to glazing j areas and types. The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The installing hvac contractor shall provide the required CF-6R with the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the HVAC system. The installed plumber shall provide the required CF-6R listing the water heater model number(s) and certified plumbing fixtures. Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) Madlin-'s enterprises TVTTTVV Andalusia at Coral Mountain Series 75 Plan 4 with Dining boom Option • CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13.56.10 Project Address......... PLAN 4 w DINING RM OPT ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box '1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Climate Zone ...........15 Date i Compliance Method ...... -MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC -------- $ -------------------------------------------------------------------- GENERAL INFORMATION 4 ------------------- ' Conditioned Floor -Area ..... 3907 sf Building Type .............. Single Family Detached Construction Type ......... -New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories.. ....... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 20.2 % of floor afea Average Glazing U-factor... 0.4 Btu/hr-sf-F 1 Average Glazing SHGC....... 0.38 Average Ceiling Height..... 11 ft BUILDING SHELL INSULATION f. Component Frame Cavity Sheathing Total Assembly Type Type ---------- R-value -------- R-value R-value U-factor Location/Comments Wall Wood R-17.8 ---------------------- R-3.9' R-21.7 0.051 ------------------------ 1 Wall Wood R-17.8 R-0 R-17.8 0.064 Door None R=O- R-0 R-0 0.330 RoofRadiant Wood' R-11 R-27 R-38 0.025 SlabEdge None R-0 R-0 F2=0.760 SlabEdge None R-0 R-0 F2=0.'510 FENESTRATION ------------ F Over- . Orientation Area (sf) U- Factor SHGC Interior Shading Exterior Shading hang/ Fins -------------------- ----- ------ Window Back (S) 48.0 '0.380 ------ 0.350 --------------- Standard ---------- Standard ----- Yes Door Right (W), 48.0 0.380 0.350 Standard Standard - Yes i Door Back (S) 240.0 0.400 0.400 Standard Standard Yes Door Back (S) 48.0 0.380 0.350 Standard Standard Yes Door ' Back (S) 48.0 0.380 0.350 Standard Standard Yes Window Right (W) 4.0 0.380 0.350 Standard Standard None Window Right (W) 4.0 0.380 0.350 Standard Standard None_ Window Right (W) 9.0 0.380 0.350 Standard Standard None Window Right' (W) 13.5 0.380 0.350 Standard Standard None Window Right (W) 9.0 0.380 0.350 Standard Standard - None Window Right (W) 9.0 0.380 0.350 Standard Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window • Right. (W) 4.5 0.380 0.350 Standard Standard None' Window Right (W)- 4.5 0.380 0.350 Standard Standard None f I } CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13:56:10 MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program -FORM CF-1R -User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------- -------------------------------------------------------------- FENESTRATION Orientation Area (sf) U- Factor Interior Exterior Over - hang/ -- -------- ----- SHGC Shading Shading Fins Window Front (N) 15.0 ------ 0.380 ------ 0.350 --------------- Standard -------------- Standard --- None Door Window Left (E) 48.0 0.380 0.350 Standard Standard None Window Front Front (N) (N) 4.5 4.5 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None Door Right (W) 24.0 0.380 0.350 Standard Standard None None Door Window Right Left (W) (E) 24.0 4.5 0.380 0.380 0.350 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard Standard Standard. None None Window Window Left Left, (E) (E) 4.5 4.5 0.380 0.380 0.350 0.350 Standard Standard None Skylight Horz 1.0 1.720 0.830 Standard None Standard None None None Skylight Window Horz Back (S) 1.0 12.5 1.720 0.380 0.830 0.350 None Standard None Standard None Window Back (S) 12.5 0.380 0.350 Standard Standard None None Door Window Back Right (S) (W) 24.0 4.5 0.380 0.380 0.350 0.350 Standard Standard Standard None Window Right (W) 23.4 0.380 0.350 Standard Standard Standard None None Window Front'(N) 4.5 0.380 0.350 Standard Standard None Door Window Front Left (N) (E) 48.0 4.5 0.500 0.380 0.500 0.350 Standard Standard Standard None Window Left (E) 20.0 0.380 0.350 Standard Standard Standard None None SLAB SURFACES ------------- Area. Slab Type (sf) Standard Slab 3403 Standard Slab 504 HVAC SYSTEMS Equipment Minimum ------------ Refrigerant Charge and Duct Duct Tested ACCA Duct Manual Thermostat ---Type- Efficiency Airflow --------------- ----------- Location R-value Leakage D Type, Furnace 0.780 AFUE. n/a Attic ------- R-4.2 ------- ------ No No ------- Setback ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No Setback Furnace 0.780 AFUE n/a Attic R-4.2 No No Setback ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No Setback CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13.56.10 MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program -FORM CF-1R --------User#_MP0207 User-Madlin's Enterprises Run=REVISED PERMIT CALC ---------------------------------=---------------------- ------- WATER HEATING SYSTEMS Number Tank External Tank Type Heater Type --------- Distribution ------------------- in Type System Energy Factor Size (gal) Insulation R-value DHW 1 ------ -------- ------ ---------- Large Gas Recirc/TimeTemp 1 n/a 75 R-0 DHW 2 ` Storage Gas Standard 1 0.58 30 R- n/a ' WATER HEATING SYSTEMS DETAIL r---------------------------- Standby Internal Tank ` Recovery Rated Loss Insulation Pilot System Efficiency ----------- Input ------------ Fraction R-value Light .DHW 1 ------------------------- ------- - Large 0.78 n/a 0.03 R-n/a 0 F SPECIAL FEATURES AND MODELING ASSUMPTIONS --------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions This printout is for the front facing North. This building incorporates a Radiant Barrier. The radiant barrier must have }., an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, r and must meet attic ventilation criteria. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION -------------------------- ** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-lR Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13:56:10 MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----- ----------------------------------------------------------------------- REMARKS This revised calculation reflects updates/changes to glazing areas and types. i The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is,responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The installing hvac contractor shall provide the required CF-6R .with the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the HVAC system. ' The installed plumber shall provide the required CF-6R listing the water heater model number(s) and certified plumbing fixtures. N CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 5 CF-lR ------------------------------ _________________________________ Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13.56.10 -MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program -FORM CF-lR I User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----- ---------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER -Name.... Company. CORAL OPTION 1, LLC Address. P.O. BOX 1716 LA QUINTA, CA 92253 Phone... 760-777-7747 License. Signed.. fi at ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... CATHERINE M. MADLIN Company. Madlin's Enterprises Address. P.O. Box 1443 Palm Springs, CA 92262 Phone... 760-322-5004 Certified Energy Analyst Catherine M. Madlin NR 98-90-544 r r rr R 98-90-144 CADEC California Association of Building Energy Consultants COMPUTER METHOD SUMMARY. Page 1 C-2R Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13.56.10 Project Address........ PLAN 4 w DINING RM OPT ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author..: CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC -------- -------------------------------------------------------------------- = MICROPAS6 - -------------------------------- ENERGY USE SUMMARY = -------------------------P-- ' = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) --------- Design -----_---- Design Margin = = Space Heating.......... ------- 4.34 -----�---- 3.90 0.44 = Space Cooling.......... 38.92 33.34 5.58 = = Water Heating.......... 7.29 9.80 -2.51 = = North Total ---------------- 50.55 -------- 47.04 _ 3.51 - = Space Heating.......... 4.34 4.40 -0.06 = = Space Cooling.......... 38.92 33.45 5.47 = = Water Heating.......... 7.29 9.80 -2.51 = East Total -------- -------- 50.55 -------- 47.65 2.90 = Space Heating.......... 4.34 4.50 -0.16 = = Space Cooling.......... 38.92 33.42 5.50 = = Water Heating.......... 7.29 9.80 -2.51 = South Total -------- -------- 50.55 -------- 47.72 2.83 = Space Heating.......... 4.34 3.77 0.57 = = Space Cooling.......... 38.92 34.17 4.75 = = Water Heating.......... 7.29 9.80 -2.51 = = West Total ---------------- 50.55 -------- 47.74 _ 2.81 = _ *** Building complies with Computer Performance*** _ GENERAL INFORMATION ------------------- Conditioned Floor Area..... 3907 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 2 COMPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13:56:10 MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------- ------------------------------------------------------------------ Conditioned Volume......... 42912 cf Slab -On -Grade Area......... 3907 sf Glazing Percentage......... 20.2 % of floor area Average Glazing U-factor... 0.4 Btu/hr-sf-F Average Glazing SHGC....... 0.38 Average Ceiling Height..... 11 ft BUILDING ZONE INFORMATION Floor # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage Zone Type -------------- (sf) ----- (cf) ------- Units itioned Type (ft) (sf) Credit 1.ZONE ----- ------- ----------- ----- -------- --------- Residence 3403 37872 0.87 Yes Setback 2.0 Standard No 2.ZONE Residence 504 5040 0.13 Yes Setback 2.0 Standard No Surface 1.ZONE 1 Wall 2 Wall 3 Wall 5 Wall 7 Wall 9 Wall 13 Door 14 RoofRadiant 2.ZONE 4 Wall 6 Wall 8 Wall 10 Wall 11 Wall 12 Wall 15 RoofRadiant OPAQUE SURFACES Area U- --------------- Insul Act Solar Form 3 Location/ (sf) ----- factor ----- R-val ----- Azm --- Tilt ---- Gains ----- Reference Comments ------------ ---------------- 414 0.051 21.7 0 90 Yes W.17.8.PW2X6 1075 0.051 21.7 90 90 Yes W.17.8.PW2X6 408 0.051 21.7 180 90 Yes W.17.8.PW2X6 1000 0.051 21.7 270 90 Yes W.17.8.PW2X6 303 0.064 17.8 0 90 No W.19.2X6FIRE 115 0.064 17.8 0 90 No W.19.2X6FIRE 24 0.330 0 0 90 No None 3401 0.025 38 n/a 0 Yes R.38.2X4.24 106 0.051 21.7 180 90 Yes W.17.8.PW2X6 170 0.051 21.7 270 90 Yes W.17.8.PW2X6 508 0.064 17.8 0 90 No W.19.2X6FIRE 13 0.051 21.7 135 90 Yes W.17.8.PW2X6 120 0.051 21.7 225 90 Yes W.17.8.PW2X6 13 0.051 21.7 315 90 Yes W.17.8.PW2X6 504 0.025 38 n/a 0 Yes R.38.2X4.24 Length Surface (ft) 1.ZONE 16 SlabEdge 270 18 SlabEdge 33 2.ZONE 17 SlabEdge 50 19 SlabEdge 51 PERIMETER LOSSES ---------------- F2 Insul Solar Factor R-val Gains Location/Comments --------------- --------------------------- 0.760 R-0 No 0.510 R-0 No 0.760 R-0 No 0.510 R-0 No COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13:56:10 ------------ -MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----- ------------------------------------------------------------------ Orientation ---------------------- 1.ZONE 1 Window Back (S) 2 Door Right (W) 3 Door Back (S) 4 Door Back (S) 5 Door Back (S) 6 Window Right (W) 7 Window Right (W) 8 Window Right (W) 9 Window Right (W) 10 Window Right (W) 11 Window Right (W) 12 Window Right (W) 13 Window Right (W) 14 Window Right (W) 15 Window Front (N) 16 Door Left (E) 17 Window Front (N) 18 window Front (N) 19 Door Right (W) 20 Door Right (W) 21 Window Left (E) 22 Window Left (E) 23 Window Left (E) 24 Window Left (E) 25 Skylight Horz 26 Skylight Horz 32 Window Front (N) 33 Door Front (N) 34 Window Left (E) 35 Window Left (E) 2.ZONE 27 Window Back (S) 28 Window Back (S) 29 Door Back (S) 30 Window Right (W) 31 Window Right (W) FENESTRATION SURFACES --------------------- Area U- Act Exterior Shade Interior Shade (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC ----- ----- ----- --- -------------------------------- 48.0 0.380 0.350 180 90 48.0 0.380 0.350 270 90 240.0 0.400 0.400 180 90 48.0 0.380 0.350 180 90 48.0 0.380 0.350 180 90 4.0 0.380 0.350 270 90 4.0 0.380 0.350 270 90 9.0 0.380 0.350 270 90 13.5 0.380 0.350 270 90 9.0 0.380 0.350 270 90 9.0 0.380 0.350 270 90 4.5 0.380 0.350 270 90 4.5 0.380 0.350 270 90 4.5 0.380 0.350 270 90 15.0 0.380 0.350 0 90 48.0 0.380 0.350 90 90 4.5 0.380 0.350 0 90 4.5 0.380 0.350 0 90 24.0 0.380 0.350 270 90 24.0 0.380 0.350 270 90 4.5 0.380 0.350 90 90 4.5 0.380 0.350 90 90 4.5 0.380 0.350 90 90 4.5 0.380 0.350 90 90 1.0 1.720 0.830 0 0 1.0 1.720 0.830 0 0 4.5 0.380 0.350 0 90 48.0 0.500 0.500 0 90 4.5 0.380 0.350 90 90 20.0 0.380 0.350 90 90 12.5 0.380 0.350 180 90 12.5 0.380 0.350 180 90 24.0 0.380 0.350 180 90 4.5 0.380 0.350 270 90 23.4 0.380 0.350 270 90 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 None/1 None/1 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 None/1 None/1 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 OVERHANGS AND SIDE FINS ----------------------- ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface -(sf) Wdth ----- Hgth ----- Dpth ---- Hght ---- Ext Ext Ext Dpth Hght Ext Dpth Hght 1.ZONE ---- ---- ---- ---- ---- ---- - 1 Window 48.0 8 6 1 0 n/a n/a n/a n/a n/a n/a n/a n/a 2 Door 48.0 6 8 25.5 6 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 240.0 20 12 16.5 2 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 48.0 6 8 11 2 n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 48.0 6 8 11 2 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13.56.10 -----MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----------------------------------------------------------------------- SLAB SURFACES Area Slab Type ------ (sf) -------- ------ Standard Slab 3403 2.ZONE Standard Slab 504 HVAC SYSTEMS ------------ Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type Efficiency ---------- Airflow Location R-value Leakage D Eff 1.ZONE -------------------- ------- --------- -------- ---- Furnace 0.780 AFUE n/a Attic R-4.2 No No 0.743 ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No 0.637 2.ZONE Furnace 0.780 AFUE n/a Attic R-4.2 No No 0.743 ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No 0.637 WATER HEATING SYSTEMS Number Tank External Tank Type Heater Type ---------- Distribution ------------------- in Type System Energy Factor .(gal) Size Insulation R-value DHW 1 ------ -------- ------ 1 Large Gas Recirc/TimeTemp 1 n/a 75 R-0 DHW 2 ' 2 Storage Gas Standard 1 0.58 30 R- n/a WATER HEATING ---------------------------- SYSTEMS DETAIL Standby Internal Tank Recovery Rated Loss Insulation Pilot System ------------ Efficiency ------------ Input ------------ Fraction R-value Light DHW 1 ------------------------- ------- 1 Large 0.78 n/a 0.03 R-n/a 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. ' This printout is for the front facing North. This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. COMPUTER METHOD SUMMARY Page 5 C-2R ° Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13:56:10 MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ---------------------------------------------------- SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- f This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION ------------------------- *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** ** CEC approved testing and/or verification methods.and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. ( REMARKS This revised calculation reflects updates/changes to glazing areas and types. The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy .Conservation Standards. The owner may (at his/her option) install 'better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and i equipment selection(s). The HVAC design shall be done in accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic r load must be adjusted for additional design conditions and system/equipment performance. The installing hvac contractor shall provide the required CF-6R with the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the HVAC system. The installed plumber shall provide the required CF-6R listing the water heater model number(s) and certified plumbing + fixtures. Madlin-'s enterprises Catherine M. Madlua, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) . Andalusia at Coral Mountain Series 75 - Plan 5 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:57:27 Project Address........ PLAN 5 ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building -Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-24580B1 Wth-CTZ15S92 Program -FORM CF-1R -------User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC I --------------------------------------------------------- GENERAL INFORMATION ------------------- Conditioned Floor Area..... 4314 sf . Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories.. ...... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 17.8 % of floor area Average Glazing U-factor... 0.4 Btu/hr-sf-F Average Glazing SHGC....... 0.38 Average Ceiling Height..... 10.8 ft BUILDING SHELL INSULATION Component Frame ------------------------- Cavity Sheathing Total Assembly Type ----- Type ---- R-value -------- R-value R-value U-factor Location/Comments Wall Wood R-17.8 ---------------------- ------------------------ R-3.9 R-21.7 0.051 Wall Wood R'-17.8 R-0 R-17.8 0.064 Wall Wood R-13 R-0 R-13 0.088 2x4 Studs Door None R-0 R-0 R-0 0.330 RoofRadiant Wood R-11 R-27 R-38 0.025 SlabEdge None R-0 R-0 F2=0.760 S1abEdge None R-0 R-0 F2=0.510 FENESTRATION ------------ Area U- Interior Exterior Over- hang/ Orientation -------- (sf) ----- ------ Factor SHGC Shading Shading Fins Door Back (S) 24.0 ------ 0.380 --------------- 0.350 Standard -------------- Standard ----- Yes Door Back (S) 24.0 0.380 0.350 Standard Standard Yes Door Back (S) 24.0 0.380 0.350 Standard Standard Yes Door Back (S) 24.0 0.380 .0.350 Standard Standard Yes Door Back (S) 48.0 0.380 0.350 Standard Standard Yes Door Back (S) 24.0 0.380 0.350 Standard Standard Yes Door Back (S) 240.0 0.400 0.400 Standard Standard Yes Window Right (W) 3.8 0.380 0.350 Standard Standard None Window Right (W) 3.8 0.380 0.350 Standard Standard None Window Right (W) 3.8 0.380 0.350 Standard Standard None Window Front (N) 4.5 0.380 0.350 Standard Standard None Window Front (N) 12.5 0.380 0.350 Standard Standard None Window Front (N) 4.5 0.380 0.350 Standard Standard None CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... ANDALUSIA.PLAN.S Date..11/09/04 13:57:27 -----MICROPAS6-v601- File-24580B1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC -------------------------------------------------- ------- FENESTRATION ------------ Over- Orientation ---------- Area (sf) ----- U- Factor ------ SHGC Interior Shading Exterior Shading hang/ Fins Window Front (N) 7.5 0.380 ------ 0.350 --------------- Standard -------------- Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Right (W) 7.5 0.380 0.350 Standard Standard. None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Right (W) 7.5 0.380 0.350 Standard Standard None Window Front (N) 5.0 0.380 0.35.0 Standard Standard None Window Right (W) 20.0 0.380 0.350 Standard Standard None Window Front (N) 20.0 0.380 0.350 Standard Standard None Window Window Back Right (S) (W) 4.5 4.5 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard None None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Window Front Left (N) (E) 23.4 4.5 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None, Window Left (E) 4.5 0.380 0.350 Standard Standard None None i Window Window Left Left (E) (E) 25.0 4.5 0.380 0.380 0.350 0.350 Standard Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard Standard None None Window Window Left Left (E) (E) 4.5 12.5 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None Window Left (E) 12.5 0.380 0.350 Standard Standard None None Window Window Left Left (E). (E) 4.5 4.0 0.380 0.380 0.350 0.350 Standard Standard Standard None Window Left (E) 4.0 0.380 0.350 Standard Standard Standard None None 'Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Window Window Back Left (S) 4.5 0.380 0.350 Standard Standard None Window Left (E) (SE) 10.0 10.0 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None None Window Back (S) 10.0 0.380 0.350 Standard Standard None Window Right.(W) 4.5 0.380 0.350 Standard Standard None Window Right (W) 4.5. 0.380 0.350 Standard Standard None Window Right (W) 25.0 0.380 0.350 Standard Standard None Window Front (N) 4.5 0.380 0.350 Standard Standard None Door Front (N) 48.0 0.500 0.500 Standard Standard None SLAB SURFACES ------------- Area Slab Type (sf) Standard Slab 3827 Standard Slab 487 n CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:57:27 MICROPAS6 v6.01 File-24580B1 Wth-CTZ15S92 Program -FORM CF-lR --------User#_MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----------------------------------------------------------------- HVAC SYSTEMS Equipment Refrigerant Tested ACCA Minimum Charge and Duct Duct Duct Manual Thermostat ---Type- Efficiency Airflow Location R-value Leakage D -------------------------- Type Furnace -------------- ------ 0.780 AFUE n/a Attic R-4.2 No No ---------- Setback ACSplitTXV '12.00 SEER Yes Attic R-4.2 No No Setback i HPSplit ' 6.80 HSPF n/a Attic R-4.2 No No Setback HPSplit i 10.00 SEER No Attic R-4.2 No No Setback WATER HEATING SYSTEMS --------------------- Number Tank External Tank Type in Energy Size Heater Type Distribution Type System Factor (gal) ----------- Insulation R-value DHW 1 ------------------- -------------- ------ ---------- .Large Gas Recirc/TimeTemp 1 n/a 75 R-0 i DHW 2 Storage Gas Standard 1 0.58 30 R- n/a WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss Insulation Pilot System ----- Efficiency Input Fraction R-value, ------------------------ Light DHW 1 ------------------------- ------- Large 0.78 n/a 0.03 R-n/a 0 +, SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------- *** ------------------------ Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Radiant Barrier. The radiant barrier must have t an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). f 'This building incorporates non-standard Water Heating System CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-1R Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:57:27 ------MICROPAS6 v6.01 File-24580B1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC -------------------------------------------------------------------- HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** ** CEC approved testing and/or verification methods.and *** i *** must be reported on the CF-6R installation certificate. *** This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning :' system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS This revised calculation reflects updates/changes to glazing areas and types. The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and 1 equipment selection(s). The HVAC design shall be done in accordance with industry standards. The load calculation in a this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and. system/equipment performance. The installing hvac contractor shall provide the required CF-6R i with the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the HVAC system. The installed plumber shall provide the required CF-6R listing the water heater model number(s) and certified plumbing i fixtures. , CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 5 CF-1R Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13.57.27 ------MICROPAS6v6- 01-File-24580B1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC - ------------------------ ------------- ------- ----- ------- COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special,Features Modeling Assumptions section. i DESIGNER or OWNER , DOCUMENTATION AUTHOR Name... . Company. CORAL OPTION 1, LLC Address. P.O. BOX 1716 LA QUINTA, CA 92253 Phone... 760-777-7747 LicenseCna:4( Signed.i p te) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) Name.... CATHERINE M. MADLIN Company. Madlin's Enterprises Address. P.O. Box 1443 Palm Springs, CA 92262 Phone... 760-322-5004 Signed.. (date) Certified Energy Analyst Catherine M. Madiin " NR 98-90-544 r,/\ nrrrl R 98-90-144 CAB EC I COUOM10 Anodonon of Building Energy 'ConsulraM COMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:57:27 Project Address........ PLAN 5 ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-24580B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----- ----------------------------------------------------------------------- = MICROPAS6 -------------------------------- ENERGY USE SUMMARY = ------------------------P-- _ Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) -------- Design Design ---------- Margin = = Space Heating.......... ---------- 4.64 ---------- 4.23 0.41 = Space Cooling.......... 37.70 32.61 5.09 = = Water Heating.......... 6.61 8.88 -2.27 = North Total -------- -------- 48.95 -------- 45.72 3.23 = Space Heating.......... 4.64 4.25 0.39 = = Space Cooling.......... 37.70 33.58 4.12 = = Water Heating.......... 6.61 8.88 -2.27 = East Total -------- -------- 48.95 -------- 46.71 2.24 = Space Heating.......... 4.64 4.35 0.29 = = Space Cooling.......... 37.70 33.35 4.35 = = Water Heating.. ....... 6.61 8.88 -2.27 = South Total -------- -------- 48.95 -------- 46.58 2.37 = Space Heating.. ...... 4.64 4.08 0.56 = = Space Cooling.......... 37.70 33.77 3.93 = = Water Heating.......... 6.61 8.88 -2.27 = West Total -------- -------- 48.95 -------- 46.73 2.22 _ *** Building complies ---------------- with Computer Performance GENERAL INFORMATION ------------------- Conditioned Floor Area..... 4314 sf Building Type .............. Single Family Detached Construction Type .. New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction -Type.... Slab On Grade Number of Building Zones... 2 COMPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13.57.27 MICROPAS6 v6.01 File-24580B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------------------------------------------------------------------------------- Conditioned Volume......... 46404 cf Slab -On -Grade Area......... 4314 sf Glazing Percentage......... 17.8 % of floor area k Average Glazing U-factor... 0.4 Btu/hr-sf-F Average Glazing SHGC....... 0.38 Average Ceiling Height..... 10.8 ft BUILDING ZONE INFORMATION ------------------------- • Floor # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage Zone Type (sf) (cf) Units itioned Type (ft) (sf) Credit -------------- ------------ ----------------------- ---------------------- 1.ZONE Residence 3827 41534` 0.89 Yes Setback 2.0 Standard No, 2.ZONE Residence 487 4870 0.11 Yes Setback 2.0 Standard No OPAQUE SURFACES --------------- Area U- Insul Act Solar Form 3 Location/ Surface (sf) factor R-val Azm Tilt Gains Reference Comments -------------- ------ ----- ----- --- ---- ----------------- ---------------- ' 1.ZONE 1 Wall 486 0.051 21.7 0 90 Yes W.17.8.PW2X6 { 3 Wall 931 0.051 21.7 90- 90 Yes W.17.8.PW2X6 5 Wall 407 0.051 21.7 180 90 Yes W.17.8.PW2X6 7 Wall 961 0.051 21.7 270 90 Yes W.17.8.PW2X6 9 Wall 174 0.064 17.8 0 90 No W.19.2X6FIRE 11 Wall 83 0.088 13 0 90 No W.13.2X4.16 2x4 Studs 13 Door 24 0.330 0 0 90 No None 15 RoofRadiant 3823 0.025 38 n/a 0 Yes R.38.2X4.24 { 2.ZONE 2 Wall 66 0.051 21.7 0 90 Yes W.17.8.PW2X6 4 Wall 356 0.051 21.7 90 90 Yes W.17.8.PW2X6 6 Wall 133 0.051 21.7 180 90 Yes W.17.8.PW2X6 8 Wall 219 0.051 21.7 270 90 Yes W.17.8.PW2X6 10 Wall 283 0.064 17.8 0 90 No W.19.2X6FIRE 12 Wall 78 0.088 13 0 90 No W.13.2X4.16 2x4 Studs 14 Door 24 0.330 0 0 90 No None 16 RoofRadiant 487 0.025 38 n/a 0 Yes R.38.2X4.24 i PERIMETER LOSSES ---------------- Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- 1.ZONE 17 SlabEdge 304 0.760 R-0 No 19 SlabEdge 20 0.510 R-0 No 2.ZONE 18 SlabEdge 94 0.760 R-0 No 20 SlabEdge 28 0.510 R-0 No COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13.57.27 MICROPAS6 v6.01 File-24580B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC -------- -------------------------------------------------------------------- Orientation 1.ZONE 1 Door 2 Door 3 Door 4 Door 5 Door 6 Door 7 Door 8 Window 9 Window 10 Window 11 Window 12 Window 13 Window 14 Window 15 Window 16 Window 17 Window 18 Window 19 Window 20 Window 21 Window 22 Window 23 Window 24 Window 25 Window 26 Window 27 Window 28 Window 29 Window 30 Window 31 Window 32 Window 33 Window 34 Window 35 Window 36 Window 37 Window 38 Skylight 39 Skylight 40 Skylight 41 Skylight 50 Door 2.ZONE 42 Window 43 Window 44 Window 45 Window 46 Window 47 Window 48 Window FENESTRATION SURFACES --------------------- Area U- Act Exterior Shade Interior Shade (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC ----- ----- ----- --- ---- -------------- -------------- Back (S) 24.0 0.380 0.350 180 90 Back (S) 24.0 0.380 0.350 180 90 Back (S) 24.0 0.380 0.350 180 90 Back (S) 24.0 0.380 0.350 180 90 Back (S) 48.0 0.380 0.350 180 90 Back (S) 24.0 0.380 0.350 180 90 Back (S) 240.0 0.400 0.400 180 90 Right (W) 3.8 0.380 0.350 270 90 Right (W) 3.8 0.380 0.350 27.0 90 Right (W) 3.8 0.380 0.350 270 90 Front (N) 4.5 0.380 0.350 0 90 Front (N) 12.5 0.380 0.350 0 90 Front (N) 4.5 0.380 0.350 0 90 Front (N) 7.5 0.380 0.350 0 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 7.5 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 7.5 0.380 0.350 270 90 Front (N) 5.0 0.380 0.350 0 90 Right (W) 20.0 0.380 0.350 270 90 Front (N) 20.0 0.380 0.350 0 90 Back (S) 4.5 0.380 0.350 180 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Front (N) 23.4 0.380 0.350 0 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 25.0 0.380 0.350 90 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 12.5 0.380 0.350 90 90 Left (E) 12.5 0.380 0.350 90 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 4.0 0.380 0.350 90 90 Left (E) 4.0 0.380 0.350 90 90 Horz 1.0 1.720 0.830 0 0 Horz 1.0 1.720 0.830 0 0 Horz 1.0 1.720 0.830 0 0 Horz 1.0 1.720 0.830 0 0 Front (N) 48.0 0.500 0.500 0 90 Back (S) 4.5 0.380 0.350 180 90 Left (E) 10.0 0.380 0.350 90 90 Left (SE) 10.0 0.380 0.350 135 90 Back (S) 10.0 0.380 0.350 180 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 25.0 0.380 0.350 270 90 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 None/l None/1 None/1 None/1 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 None/1 None/1 None/1 None/l Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 \ - COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... ANDALUSIA.PLAN.S Date..11/09/04 13.57.27 MICROPAS6 v6.01 File-24580B1 Wth-CTZ15S92 Program -FORM C-2R --------User#_MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------------------- ------------ ------------- ------- ----- ------- FENESTRATION SURFACES --------------------- Area U- Act Exterior Shade Interior Shade Orientation (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC ------------ ----- ----- ----- --- -------------------------------- 49 Window Front (N) 4.5 0.380 0.350 0 90 Standard/0.76 Standard/0.68 OVERHANGS AND SIDE FINS ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface (sf) - ----- Wdth ----- Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght 1.ZONE ----- ---- ---- ---- ---- ---- 1 Door 24.0 3 8 10 2 n/a n/a n/a n/a n/a n/a n/a n/a 2 Door 24.0 3 8 10 2 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 24.0 3 8 10 2 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 24.0 3 8 11.5 2 n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 48.0 6 8 11.5 2. n/a n/a n/a n/a n/a n/a n/a n/a *6 Door 24.0 3 8 11.5 2 n/a n/a n/a n/a n/a n/a n/a n/a 7 Door 240.0 20 12 16.5 2 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES ------------- Area Slab Type ----------- (sf) 1.ZONE ------ Standard Slab 3827 2.ZONE Standard Slab 487 HVAC SYSTEMS Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type --- Efficiency ----------- Airflow Location R-value Leakage D Eff 1.ZONE -------------------- ------- --------- -------- ---- Furnace 0.780 AFUE n/a Attic R-4.2 No No 0.743 ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No 0.637 2.ZONE HPSplit 6.80 HSPF n/a Attic R-4.2 No No 0.772 HPSplit 10.00 SEER No Attic R-4.2 No No 0.637 Tank Type Heater Type -------- DHW 1 1 Large Gas DHW 2 2 Storage Gas WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Distribution Type System Factor (gal) R-value Recirc/TimeTemp 1 n/a 75 R-0 Standard 1 0.58 30 R- n/a COMPUTER METHOD SUMMARY Page 5 C-2R Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:57:27 MICROPAS6 v6.01 File-24580B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC -------- -------------------------------------------------------------------- System ------------ DHW 1 1 Large WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss Insulation Pilot Efficiency Input Fraction R-value Light ----------------------------------------------------- 0.78 n/a 0.03 R-n/a 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection., *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** *** must be reported on the CF-6R installation certificate. *** I ' This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS This revised calculation reflects updates/changes to glazing areas and types. The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in COMPUTER METHOD SUMMARY Page 6 C-2R Project Title.......... ANDALUSIA.PLAN.S Date..11/09/04 13:57:27 MICROPAS6 v6.01 File-24580B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------- --------------------------------------------- REMARKS accordance with industry standards. The load calculation in 4 this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic t load must be adjusted for additional design conditions and r system/equipment performance. The installing hvac contractor shall provide the required CF-6R with the installed hvac equipment model numbers. i j A night setback thermostat is required to be installed with the HVAC system. The installed plumber shall provide the required CF-6R listing the water heater model number(s) and certified plumbing fixtures. i Madlin-'s enterprises Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) v v v v v v Andalusia at Coral Mountain Series 75 Plan 5 - Lot H . - Detached G.H. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:58:45 Project Address........ LOT 11 - PLAN 5 DET.GH ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan C ec Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone........... 15 --------------------- + Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. _______________ MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program -FORM CF-1R •.� ------User#-MP0207 User-Madlin's Enterprises Run -LOT 11 REV PERMIT CALC ---------------------------------------------------------------- ---- GENERAL INFORMATION Conditioned Floor Area..... 4314 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units-. 1 , Number of Stories.. ........ 1 Floor Construction Type Slab On Grade Glazing Percentage......... 17.9 % of floor area' Average Glazing U-factor... 0.4 Btu/hr-sf-F Average Glazing SHGC....... 0.38 Average Ceiling Height..... 10.8 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type Type -- R-value R-value R-value U-factor Location/Comments Wall ------- Wood -------- R-17.8 ---------------------- R-3.9 R-21.7 0.051 ------------------------ Wall Wood R-17.8 R-0 R-17.8 0.064 Wall Wood R-13 R-0 R-13 0.088 2x4 Studs Door None R-0 R-0 R-0 0.330 Roof Radiant Wood R-11 R-27 R-38 0.025 S1abEdge None R-0 R-0 F2=0.760 SlabEdge None R-0 R-0 F2=0.510 FENESTRATION ------------ t ' Over - Area U- Interior Exterior hang/ Orientation f-------------------- (sf) ----- Factor ------ SHGC Shading Shading Fins Door Back (S) 24.0 0.380 --------------------- 0.350 Standard ------- ----- Standard -- Yes Door Back (S) 24.0 0.380 0.350 Standard Standard Yes Door Back (S) 24.0 0.380 0.350 Standard Standard Yes Door Back (S) 24.0 0.380 0.350 Standard Standard Yes Door Back (S) 48.0 0.380 0.350 Standard Standard Yes Door Back (S) 24.0 0.380 0.350 Standard Standard Yes Door Back (S) 240.0 0.400 0.400 Standard Standard Yes }' Window Right (W) 3.8 0.380 0.350 Standard Standard None Window Right (W) 3.8 0.380 0.350 Standard Standard None Window Right (W) 3.8 0.380 0.350 Standard Standard None Window Front (N) 4.5 0.380 0.350 Standard Standard None - Window Front (N) 12.5 0.380 0.350 Standard Standard None Window 'Front (N) 4.5 0.380 0.350 Standard Standard None CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:58.45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin's Enterprises Run -LOT 11 REV PERMIT CALC ------------------------------------------------------------------------------- FENESTRATION ------------ Over- Area U- Interior Exterior hang/ Orientation -------------------- (sf) Factor SHGC Shading Shading Fins window Front (N) ----- 7.5 ------ 0.380 ------ 0.350 --------------- Standard -------------- Standard ----- None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Right (W) 7.5 0.380 0.350 Standard Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard None i Window Right (W) 7.5 0.380 0.350 Standard Standard None Window Front (N) 5.0 0.380 0.350 Standard Standard None Window Right (W) 20.0 0.380 0.350 Standard Standard None i Window Front (N) 20.0 0.380 0.350 Standard Standard None Window Back (S) 4.5 0.380 0.350 Standard Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Front (N) 23.4 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None ' Window Left (E) 25.0 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None i Window Left (E) 12.5 0.380 0.350 Standard Standard None Window Left (E) 12.5 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None Window Left (E) 4.0 0.380 0.350 Standard Standard None Window Left (E) 4.0 0.380 0.350 Standard Standard None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None' None None Skylight Horz 1.0 1.720 0.830 None None None Window Back (S) 4.5 0.380 0.350 Standard Standard None Window Left (E) 10.0 0.380 0.350 Standard Standard None Window Left (SE) 10.0 0.380 0.350 Standard Standard None Window Back (S) 10.0 0.380 0.350 Standard Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Right (W) 25.0 0.380 0.350 Standard Standard None Window Front (N) 4.5 0.380 0.350 Standard Standard None Door Front (N) 48.0 0.500 0.500 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None SLAB SURFACES ------------- Area Slab Type ---------------- (sf) ------ Standard Slab 3827 Standard Slab 487 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-lR Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:58:45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin's Enterprises Run -LOT 11 REV PERMIT CALC ------ -----------------------------------=---------------------------------- HVAC SYSTEMS Refrigerant Tested ACCA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat Type Efficiency Airflow Location R-value Leakage D Type -------------------------------------------------------- ---------------- Furnace 0.780 AFUE n/a Attic R-4.2 No No Setback ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No Setback HPSplit 6.80 HSPF n/a Attic R-4.2 No No Setback HPSplit 10.00 SEER No Attic R-4.2 No No Setback WATER HEATING SYSTEMS --------------------- Number Tank External in EnerSize Tank Type Heater Type Distribution Type System Factor (gal) Rnvalueion ------------------------------------------ -------------- ---------------- DHW 1, Large Gas Recirc/TimeTemp 1 n/a 75 R-0 DHW 2 Storage Gas Standard 1 0.58 30 R- n/a Y WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R-value Light -------------------------------------------------------------------- DHW 1 Large 0.78 n/a 0.03 R-n/a 0 i SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items,in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *`** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). This building incorporates non-standard Water Heating System CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-lR Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:58:45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin's Enterprises Run -LOT 11 REV PERMIT CALC ------------------------------------------------------------------------------- F HERS REQUIRED VERIFICATION -------------------------- *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** i *** must be reported on the CF-6R installation certificate. *** This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS This revised calculation reflects updates/changes to glazing areas and types. F The values and materials used in this compliance portfolio are �. the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor. is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The installing hvac contractor shall provide the required CF-6R with the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the HVAC system. The installed plumber shall provide the required CF-6R listing the water heater model number(s) and certified plumbing fixtures. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 5 CF-1R Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13.58.45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program -FORM CF-1R ------User#_MP0207 User-Madlin's Enterprises Run -LOT 11 REV PERMIT CALC I --------------------- ------------ --------- ------- ------- ----- ------ COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to. implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER Name.... Company. CORAL OPTION 1, LLC Address. P.O. BOX 1716 LA QUINTA, CA 92253 Phone... 760-777-7747 License. Signed.. YV p ( a e) ENFORCEMENT AGENCY Name.. i Title... Agency.. t Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... CATHERINE M. MADLIN Company. Madlin's Enterprises Address. P.O. Box 1443 Palm Springs, CA 92262 Phone... 760-322-5004 Signed.. (date) Certified Energy Anagyst Catherine M. Madlin NR 98.90-544 r r rr R 98-90-144 CAB EC California Association of Building Energy Consult4nrs COMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13.58.45 Project Address........ LOT 11 - PLAN 5 DET.GH ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 ------------------ Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises ------------------------------------------------------------------------------- Run -LOT 11 REV PERMIT CALC = MICROPAS6 ENERGY USE SUMMARY = --------------------- = Energy Use Standard Proposed _ Compliance = _ (kBtu/sf-yr) Design ---------------------------------- Design Margin = = Space Heating...,....... 4.64 ---------- 4.23 ---------- _ 0.41 - - Space Cooling.......... 37.71 32.69 5.02 _ = Water Heating.......... 6.61 8.88 -2.27 = _ -------- North Total 48.96 -------- 45.80 -------- 3.16 = Space Heating.......... 4.64 4.24 0.40 = - Space Cooling.......... 37.71 33.65 4.06 = = Water Heating.......... 6.61 8.88 -2.27 = = ------ East Total 48.96 -------- 46.77 -------- - 2.19 = = Space Heating.......... 4.64 4.36 0.28 = - Space Cooling.......... 37.71 33.43 4.28 = = Water Heating.......... 6.61 8.88 -2.27 = -------- South Total 48.96 -------- 46.67 -------- 2.29 = Space Heating.......... 4.64 4.09 0.55 - = Space Cooling.......... 37.71 33.81 3.90 = = Water Heating.......... 6.61 8.88 -2.27 = = -------- West Total 48.96 -------- 46.78 -------- _ 2.18 = _ *** Building complies with Computer Performance GENERAL INFORMATION ------------------- Conditioned Floor Area..... 4314 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 2 COMPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13.58.45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -LOT 11 REV PERMIT CALC ------------------------------------------------------------------------------- Conditioned Volume......... 46404 cf Slab -On -Grade Area......... 4314 sf Glazing Percentage......... 17.9 % of floor area Average Glazing U-factor... 0.4 Btu/hr-sf-F Average Glazing SHGC....... 0.38 Average Ceiling Height..... 10.8 ft ! BUILDING ZONE INFORMATION ------------------------- Floor # of Vent Vent Air Area Volume Dwell Cond- 'Thermostat Height Area Leakage Zone Type (sf) (cf) Units itioned Type (ft) (sf) Credit -------------- ------------ ----------------------- ---------------------- 1.ZONE Residence 3827 41534 0.89 Yes Setback 2.0 Standard No 2.ZONE Residence 487 4870 0.11 Yes Setback 2.0 Standard No OPAQUE SURFACES --------------- Area U- Insul Act Solar Form 3 Location/ Surface (sf) factor R-val Azm Tilt Gains Reference Comments -------------- ------ ----- ----- --- ---- ------------------------------ 1.ZONE 1 Wall 486 0.051 21.7 0 90 Yes W.17.8.PW2X6 3 Wall 931 0.051 21.7 90 90 Yes .W.17.8.PW2X6 5 Wall 407 0.051 21.7 180 90 Yes W.17.8.PW2X6 7 Wall 961 0.051 21.7 270 90 Yes W.17.8.PW2X6 9 Wall 174 0.064 17.8 0 90 No W.19.2X6FIRE 11 Wall 83 0.088 13 0 90 No W.13.2X4.16 2x4 Studs 13 Door 24 0.330 0 0 90 No None 15 RoofRadiant 3823 0.025 38 n/a 0 Yes R.38.2X4.24 2.ZONE 2 Wall 66 0.051 21.7 0 90 Yes W.17.8.PW2X6 4 Wall 352 0.051 21.7 90 90 Yes W.17.8.PW2X6 6 Wall 133 0.051 21.7 180 90 Yes W.17.8.PW2X6 8 Wall 219 0.051 21.7 270 90 Yes W.17.8.PW2X6 10 Wall 283 0.064 17.8 0 90 No W.19.2X6FIRE 12 Wall 78 0.088 13 0 90 No W.13.2X4.16 2x4 Studs 14 Door 24 0.330 0 0 90 No None 16 RoofRadiant 487 0.025 38 n/a 0 Yes R.38.2X4.24 PERIMETER LOSSES ---------------- Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- --------------------- 1.ZONE 17 SlabEdge 304 0.760 R-0 No 19 SlabEdge 20 0.510 R-0 No 2.ZONE 18 SlabEdge 94 0.760 R-0 No 20 SlabEdge 28 0.510 R-0 No COMPUTER METHOD SUMMARY Page 3 C-2R -------------------------_________ Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13.58.45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -LOT 11 REV PERMIT CALC ------------------------------------------------------------------------------- Orientation 1.ZONE 1 Door 2 Door 3 Door 4 Door 5 Door 6 Door 7 Door 8 Window 9 Window 10 Window 11 Window 12 Window 13 Window 14 Window 15 Window 16 Window 17 Window 18 Window 19 Window 20 Window 21 Window 22 Window 23 Window 24 Window 25 Window 26 Window 27 Window 28 Window 29 Window 30 Window 31 Window 32 Window 33 Window 34 Window 35 Window 36 Window 37 Window 38 Skylight 39 Skylight 40 Skylight 41 Skylight 50 Door 51 Window 2.ZONE 42 Window 43 Window 44 Window 45 Window 46 Window 47 Window Area (sf) FENESTRATION SURFACES --------------------- U- Act Exterior Shade Interior Shade factor SHGC Azm Tilt Type/SHGC Type/SHGC Back (S) 24.0 0.380 0.350 180 90 Back (S) 24.0 0.380 0.350 180 90 Back (S) 24.0 0.380 0.350 180 90 Back (S) 24.0 0.380 0.350 180 90 Back (S) 48.0 0.380 0.350 180 90 Back (S) 24.0 0.380 0.350 180 90 Back (S) 240.0 0.400 0.400 180 90 Right (W) 3.8 0.380 0.350 270 90 Right (W) 3.8 0.380 0.350 270 90 Right (W) 3.8 0.380 0.350 270 90 Front (N) 4.5 0.380 0.350 0 90 Front (N) 12.5 0.380 0.350 0 90 Front (N) 4.5 0.380 0.350 0 90 Front (N) 7.5 0.380 0.350 0 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 7.5 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 7.5 0.380 0.350 270 90 Front (N) 5.0 0.380 0.350 0 90 Right (W) 20.0 0.380 0.350 270 90 Front (N) 20.0 0.380 0.350 0 90 Back (S) 4.5 0.380 0.350 180 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Front (N) 23.4 0.380 0.350 0 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 25.0 0.380 0.350 90 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 12.5 0.380 0.350 90 90 Left (E) 12.5 0.380 0.350 90 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 4.0 0.380 0.350 90 90 Left (E) 4.0 0.380 0.350 90 90 Horz 1.0 1.720 0.830 0 0 Horz 1.0 1.720 0.830 0 0 Horz 1.0 1.720 0.830 0 0 Horz 1.0 1.720 0.830 0 0 Front (N) 48.0 0.500 0.500 0 90 Left (E) 4.5 0.380 0.350 90 90 Back (S) 4.5 0.380 0.350 180 90 Left (E) 10.0 0.380 0.350 90 90 Left (SE) 10.0 0.380 0.350 135 90 Back (S) 10.0 0.380 0.350 180 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 None/1 None/1 None/l None/1 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 None/1 None/1 None/l None/1 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 COMPUTER METHOD SUMMARY Page 4 C-2R --------------------------------------------------------- Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:58:45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -LOT 11 REV PERMIT CALC ------------------------------------------------------------------------------- FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade Orientation (sf) factor SHGC Azm Tilt Type/SHGC T ype/SHGC ---------------------- ----- ----- ----- --- -------------------------------- 48 Window Right (W) 25.0 0.380 0.350 270 90 Standard/0.76 Standard/0.68 49 Window Front (N) 4.5 0.380 0.350 0 90 Standard/0.76 Standard/0.68 OVERHANGS AND SIDE FINS ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface ----------- (sf) ----- Wdth ----- Hgth ----- Dpth Hght ---- ---- Ext Ext Ext Dpth Hght Ext Dpth Hght 1.ZONE ---- ---- ---- ---- ---- ---- ---- ---- 1 Door 24.0 3 8 10 2 n/a n/a n/a n/a n/a n/a n/a n/a 2 Door 24.0 3 8 10 2 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 24.0 3 8 10 2 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 24.0 3 8 11.5 2 n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 48.0 6 8 11.5 2 n/a n/a n/a n/a n/a n/a n/a n/a 6 Door 24.0 3 8 11.5 2 n/a n/a n/a n/a n/a n/a n/a n/a 7 Door 240.0 20 12 16.5 2 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES ------------- Area Slab Type ---------------- (sf) 1.ZONE ------ Standard Slab 3827 2.ZONE Standard Slab 487 HVAC SYSTEMS Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type ------------- Efficiency ----------- Airflow Location R-value Leakage D Eff I.ZONE -------------------- ------- --------- -------- ---- Furnace 0.780 AFUE n/a Attic R-4.2 No No 0.743 ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No 0.637 2.ZONE HPSplit 6.80 HSPF n/a Attic R-4.2 No No 0.772 HPSplit 10.00 SEER No Attic R-4.2 No No 0.637 WATER HEATING SYSTEMS Number Tank External Tank Type ------------ in Heater Type Distribution Type System ----------- Energy Factor Size (gal) Insulation R-value DHW 1 ------------------- I ------ -------- ------ ---------- 1 Large Gas Recirc/TimeTemp 1 n/a 75 R-0 DHW 2 2 Storage Gas. Standard 1 0.58 30 R- n/a COMPUTER METHOD SUMMARY Page 5 C-2R Project Title.......... ANDALUSIA.PLAN.S Date..11/09/04 13.58.45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -LOT 11 REV PERMIT CALC ------------------------------------------------------------------------------- WATER HEATING SYSTEMS DETAIL Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R-value Light ------------=------------------------------------------------------- DHW 1 1 Large 0.78 n/a 0.03 R-n/a 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) ' or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS This revised calculation reflects updates/changes to glazing areas and types. The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in COMPUTER METHOD SUMMARY Page 6 C-2R Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13.58.45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin s Enterprises Run -LOT 11 REV PERMIT CALC ------ -------------------------------------------------------------------- REMARKS accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The installing hvac contractor shall provide the required CF-6R with the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the HVAC system. The installed plumber shall provide the required CF-6R listing the water heater model number(s) and certified plumbing fixtures. 1 Madlin-'s enterprises Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) .... VVV Andalusia at Coral Mountain series 75 - Plan 6 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10:17:04 Project Address........ PLAN 6 ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone........... 15 Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. __________________________ -----MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC -------------------------------------------------------------------- GENERAL INFORMATION ------------------- Conditioned Floor Area..... 5089 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories.. ........ 1 Floor Construction Type Slab On Grade Glazing Percentage......... 18.5 % of floor area Average Glazing U-factor... 0.4 Btu/hr-sf-F Average Glazing SHGC....... 0.38 Average Ceiling Height..... 10.7 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type - Type ------- R-value -------- R-value R-value U-factor Location/Comments Wall Wood R-17.8 -------- R-3.9 ------- R-21.7 ------ ------------------ 0.051 Wall Wood R-17.8 R-0 R-17.8 0.064 Wall Wood R-13 R-0 R-13 0.088 2x4 Studs Door None R-0 R-0 R-0 0.330 ' RoofRadiant Wood R-11 R-27 R-38 0.025 S1abEdge None R-0 R-0 F2=0.760 SlabEdge None R-0 R-0 F2=0.510 FENESTRATION Orientation ---------- Area (sf)- U- Factor SHGC- Interior Shading-------- Exterior Shading Over - hang/ Fins Window Back (S) 48.0 ------ 0.380 ----- 0.350 Standard -------------- Standard ----- Yes Door Right (W) 48.0 0.380 0.350 Standard Standard Yes Door Back (S) 240.0 0.400 0.400 Standard Standard Yes Door Right (W) 120.0 0.400 0.400 Standard Standard Yes Door Window Back Back (S) (S) 48.0 15.0 0.380 0.380 0.350 0.350 Standard Standard Standard Standard Yes Window Window Right Right (W) 4.0 4.0 0.380 0.350 Standard Standard None None Window Right (W) (W) 4.5 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None None Window Window Right Right (W) (W) 13.5 13.5 0.380 0.380 0.350 0.350 Standard Standard Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard Standard None None Window Right (W) 4.5 0.380 0.350 Standard Standard None CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10:17.04 MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program -FORM CF-lR --------User#_MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----------------------------------------------------------- FENESTRATION Over - Area U- Interior Exterior hang/ Orientation ------- (sf) ----- Factor SHGC Shading Shading Fins Window Right (W) 9.0 ------ 0.380 ------ 0.350 --------------- Standard -------------- Standard ----- None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Left (E) 15.0 0.380 0.350 Standard Standard None Door Left (E) 48.0 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None Window Front (N) 4.5 0.380 0.350 Standard Standard None Window Right (W) 17.5 0.380 0.350 Standard Standard None Door Front (N) 24.0 0.380 0.350 Standard Standard None Door Front (N) 24.0 0.380 0.350 Standard Standard None Door Front (N) 24.0 0.380 0.350 Standard Standard None Window Right (W) 12.5 0.380 0.350 Standard Standard None Window Right (W) 12.5 0.380 0.350 Standard Standard None Window Right (W) 12.5 0.380 0.350 Standard Standard None Window Back (S) 12.5 0.380 0.350 Standard Standard None Window Left (E) 23.4 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None Window Left (E) 15.0 0.380 0.350 Standard Standard None Window Left (E) 15.0 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None Window Left (E) 13.5 0.380 0.350 Standard Standard None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None, None Door Window Front Left (N) (E) 48.0 4.5 0.500 0.380 0.500 0.350 Standard Standard Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None None .SLAB SURFACES ------------- Area Slab Type (sf) Standard Slab 4526 Standard Slab 563 HVAC SYSTEMS Refrigerant g Tested ACCA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat ---Type----- Efficiency Airflow --------------------------- Location R-value Leakage D Type Furnace 0.780 AFUE n/a Attic ------- R-4.2 ------- ------ No No ---------- Setback ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No Setback Furnace 0.780 AFUE n/a Attic R-4.2 No No Setback ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No Setback CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10:17:04 -----MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC --------------------------------------------------------------------- WATER HEATING SYSTEMS Number Tank External Tank Type ------------ in Heater Type Distribution Type System ------------------------------ Energy Factor Size (gal) Insulation R-value DHW 1 ------ -------- ------ ---------- Large Gas Recirc/TimeTemp 1 n/a 75 R-0 DHW 2 Storage Gas Standard 1 0.58 30 R- n/a WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction---R_value----- Light, ----------------------------------------- DHW 1 Large 0.78 n/a 0.03 R-n/a 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS ---------------------------------- *** Items in -this -section -should -be -documented -on -the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** *** must be reported on the CF-6R installation certificate. *** 'This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification, is not necessary for the RCA or TXV. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-1R Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10:17.04 MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program -FORM CF-1R -User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------- ----------------------------------------------------------------- REMARKS This revised calculation reflects updates/changes to glazing areas and types. The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report. are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The installing hvac contractor shall provide the required CF-6R with the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the HVAC system. The installed plumber shall provide the required CF-6R listing the water heater model number(s) and certified plumbing fixtures. I CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 5 CF-1R Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10:17:04 MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program -FORM CF-1R --------User#_MP0207 User-Madlin s Enterprises Run -REVISED PERMIT CALC ---------------- ------------ ------------- ------- ----- ------- COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... Company. Name.... Company. CATHERINE M. MADLIN Madlin's Enterprises CORAL OPTION 1, LLC Address. P.O. BOX 1716 Address. P.O. Box 1443 LA QUINTA, CA 92253 Palm Springs, CA 92262 Phone... 760-777 747 Phone... 760-322-5004* License. Signed W 0 Signed, 4�� ate ) ( ate) ENFORCEMENT AGENCY `. Name.... Title... t Agency.. Phone... ' Signed.. ' ,(date) 0 I Certified Energy Analyst Catherine K Madiin NR 98-00=044 r r rr R 99.90=144 CADEC Colifornio As dation.oj Building Energy Consultants COMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10:17:04 Project Address........ PLAN 6 ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ---------------- MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program -FORM C-2R -User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----_-- --------------------------------------------------------------=-- = MICROPAS6 _ --------------------------------- ENERGY USE SUMMARY _ ---------------------------- ° = Energy Use - Standard Proposed Compliance = _ (kBtu/sf-yr) ------------- Design -----�---- Design Margin = = Space Heating.......... ---------- 4.11 -------- = _ Space Cooling.......... 36.91 31.74 5.17 = = Water Heating.......... 5.60 7.53 -1.93 = North Total -------- -------- 46.62 -------- 43.24 3.38 = Space Heating.......... 4.11 3.95 0.16 = Space Cooling.......... 36.91 31.63 5.28 = = Water Heating.......... 5.60 7.53 -1.93 = East Total -------- -------- 46.62 -------- 43.11 3.51 = Space Heating.......... 4.11 3.94 0.17 = = Space"Cooling.......... 36.91 32.32 4.59 = = Water Heating.......... 5.60 7.53 -1.93 = = South Total ---------------- 46.62 -------- 43.79 2.83 = Space Heating.......... 4.11 3.75 0.36 = = Space Cooling.......... 36.91 31.38 5.53 = = Water Heating.......... 5.60 7.53 -1.93 = West Total -------- -------- 46.62 -------- 42.66 3.96 _ *** Building complies with Computer Performance GENERAL INFORMATION ------------------- Conditioned Floor Area..... 5089 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 2 COMPUTER METHOD SUMMARY Page 2 C-2R ---------------------------------------- ----------------- ----------------------------------------------- ---------- Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10:17:04 MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program -FORM C-2R -User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------- -------------------------------- ------------------------- Conditioned Volume......... 54507 cf Slab -On -Grade Area......... 5089 sf Glazing Percentage......... 18.5 % of floor area Average Glazing U-factor... 0.4 Btu/hr-sf-F Average Glazing SHGC....... 0.38 Average Ceiling Height..... 10.7 ft BUILDING ZONE INFORMATION Floor Area Volume # of Dwell Cond- Thermostat. Vent Height _ Vent Area Air Leakage Zone Type ---- '---------- (sf) (cf) Units itioned Type (ft) (sf) Credit 1.ZONE ----- -------- --------- Residence 2.ZONE 4526 48877 0.89 Yes Setback "2.0 Standard No Residence 563 5630 0.11 Yes Setback 2.0 Standard No OPAQUE SURFACES Surface Area (sf) U- factor Insul R-val Act Azm Tilt Solar Gains Form 3 Location/ Reference ------- ------ ----- ----- Comments 1.ZONE ------- ----- ------------ ---------------- .1 3 Wall 401 0.051 21.7 0 90 Yes W.17.8.PW2X6 Wall 1353 0.051 21.7 90 90 Yes W.17.8.PW2X6 5 Wall 601 0.051 21.7 180 90 Yes W.17.8.PW2X6 7 9 Wall 1054 0.051 21.7 270 90 Yes W.17.8.PW2X6 11 Wall Wall 331 0.064 17.8• 0 90 No W.19.2X6FIRE 13 Door 90 24 0.088 0.330 13 0 0 .90 0 No W.13.2X4.16 2x4 Studs y 14 RoofRadiant 4521 0.025 38 n/a 90 0 No Yes None R.38.2X4.24 2.ZONE 2 Wall 180 0.051 21.7 0 90 Yes W.17.8.PW2X6 4 Wall 302 0.051 21.7 90 90 Yes W.17.8.PW2X6 . 6 8 Wall 35 0.051 21.7 180 90 Yes W.17.8.PW2X6 10 Wall Wall 330 0.051 21.7 270 90 Yes W.17.8.PW2X6 12 Door 65 24 0.064 0.330 17.8 0 0 135 90 90 No W.19.2X6FIRE 15 RoofRadiant 563 0.025 38 n/a 0 Yes Yes None R.38.2X4.24 PERIMETER LOSSES. Length ---------------- F2 Insul Solar Surface (ft) Factor ------------ R-val Gains Location/Comments 1.ZONE -------- ------- 16 SlabEdge 357 0.760 R-0 No 18 SlabEdge 35 0.510 R-0 No 2.ZONE 17 SlabEdge 97 0.760 R-0' No 19 SlabEdge 7 0.510 R-0 No a COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10:17:04 MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program -FORM C-2R -User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------- --------------------------------------------------- Orientation ---------------------- -.ZONE 1 Window Back (S) 2 Door Right (W) 3 Door Back (S) 4 Door Right (W) 5 Door Back (S) 6 Window Back (S) 7 Window Right (W) 8 Window Right (W) 9 Window Right (W) 10 Window Right (W) 11 Window Right (W) 19 Window Left (E) 20 Window Front (N) 21 Window Right (W) 22 Door Front (N) 23 Door Front (N) 24 Door Front (N) 25 Window Right (W) 26 Window Right (W) 27 Window Right (W) 28 Window Back (S) 29 Window Left (E) 30 Window Left (E) 31 Window Left (E) 32 Window Left (E) 33 Window Left (E) 34 Window Left (E) 35 Window Left (E) 36 Skylight Horz 37 Skylight Horz 38 Skylight Horz 39 Skylight Horz 40 Skylight Horz 41 Door Front (N) 2.ZONE 12 Window Right (W) 13 Window Right (W) 14 Window Right (W) 15 Window Right (W) 16 Window Right (W) 17 Window Left (E) 18 Door Left (E) 42 Window Left (E) 43 Window Left (E) FENESTRATION SURFACES --------------------- Area U- Act Exterior Shade Interior Shade (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC 48.0 0.380 0.350 180 90 48.0 0.380 0.350 270 90 240.0 0.400 0.400 180 90 120.0 0.400 0.400 270 90 48.0 0.380 0.350 180 90 15.0 0.380 0.350 180 90 4.0 0.380 0.350 270 90 4.0 0.380 0.350 270 90 4.5 0.380 0.350 270 90 13.5 0.380 0.350 270 90 13.5 0.380 0.350 270 90 4.5 0.380 0.350 90 90 4.5 0.380 0.350 0 90 17.5 0.380 0.350 270 90 24.0 0.380 0.350 0 90 24.0 0.380 0.350 0 90 24.0 0.380 0.350 0 90 12.5 0.380 0.350 270 90 12.5 0.380 0.350 270 90 12.5 0.380 0.350 270 90 12.5 0.380 0.350 180 90 23.4 0.380 0.350 90 90 4�.5 0.380 0.350 90 90 4.5 0.380 0.350 90 90 15.0 0.380 0.350 90 90 15.0 0.380 0.350 90 90 4.5 0.380 0.350 90 90 13.5 0.380 0.350 90 90 1.0 1.720 0.830 0 0 1.0 1.720 0.830 0 0 1.0 1.720 0.830 0 0 1.0 1.720 0.830 0 0 1.0 1.720 0.830 0 0 48.0 0.500 0.500 0 90 4.5 0.380 0.350 270 90 4.5 0.380 0.350 270 90 9.0 0.380 0.350 270 90 4.5 0.380 0.350 270 90 4.5 0.380 0.350 270 90 15.0 0.380 0.350 90 90 48.0 0.380 0.350 90 90 4.5 0.380 0.350 90 90 4.5 0.380 0.350 90 90 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 None/1 None/1 None/1 None/1 None/1 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 None/1 None/1 None/1 None/1 None/l Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10.17:64 MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program -FORM C-2R -User#_MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------- ---------------------------------------------=--------- OVERHANGS AND SIDE FINS ----------------------- ---Window -- ------Overhang----- ---Left Fin--- ---Right Fin-- Left Rght Surface - -Area (sf) Wdth ----- Hgth Dpth Hght Ext ---- ----- ---- Ext Ext Dpth Hght Ext Dpth Hght 1.ZONE ---- ---- -------- ---- ---- ---- ---- 1 Window 2 48.0 8 6 .1.67 0 n/a n/a n/a n/a n/a n/a n/a n/a Door 3 48.0 6 8 30 6 n/a n/a n/a n/a n/a n/a. n/a n/a Door 4 240.0 22 12 17 2 n/a n/a n/a n/a n/a n/a n/a n/a !' Door 5 120.0 12 12 13 2 n/a n/a n/a n/a n/a n/a n/a n/a Door 48.0 6 8 28 6 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES ------------- Area Slab Type ----------- (sf) 1.ZONE ------ Standard Slab 4526 2.ZONE Standard Slab 563 HVAC SYSTEMS i. System ------------ Refrigerant Minimum Charge and Duct Tested ACCA Duct Duct Manual Duct ---Type------ Efficiency Airflow Location R-value Leakage D Eff ------------- - Furnace ,ACSplitTXV 0.780 12.00 AFUE n/a Attic SEER Yes Attic R-4.2 No No 0.743 2.ZONE R-4.2 No No 0.637 Furnace ACSplitTXV 0.780 12.00 AFUE n/a Attic SEER Yes Attic R-4.2 No No 0.743 R-4.2 No No. 0.637 WATER HEATING SYSTEMS --------------------- Number Tank External Tank Type Heater ----------- Type Distribution Type ------------------- in Energy Size Insulation System Factor (gal) R-value DHW 1 ------ ----:---- ------ 1 Large Gas Recirc/TimeTemp 1 n/a 75 R-0 DHW 2 2 Storage Gas Standard, 1 0.58 30 R- n/a COMPUTER METHOD SUMMARY Page 5 C-2R ---------------------=------------- ------------------------------------------------------------------ Project ----------- Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10:17:04 MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC -------------------- --------------- ----------- - ------------- ------- ----- ------- WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss Insulation Pilot System -Efficiency Input Fraction R-value Light ---------------------------- DHW 1--------------- 1 Large 0.78 n/a 0.03 R-n/a 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION -------------------------- *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS This revised calculation reflects updates/changes to glazing areas and types. The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in COMPUTER METHOD SUMMARY Page 6 C-2R Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10:17:04 MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC -------- REMARKS accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The installing hvac contractor shall provide the required'CF7.6R with the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the HVAC system. The installed plumber shall provide the required CF-6R listing the water heater model number(s) and certified plumbing fixtures. t Madlin's enteypfises Catherine M. Madlin, Certified Eneero Analyst v 760-322-5004 / 323-3644 (fax) . ... e Andalusia Plan 6 - Lots I at Coral Mountain Series 75 & 10. - Detached G.H. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-lR Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:01:27 Project Address........ LOTS 1 & 10 PLAN 6 ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 Climate Zone........... 760-322-5004 15 --------------------- Field C ec Date Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program -FORM CF-1R ------User#_MP0207 --------------------------=--------------------------------------- User-Madlin's Enterprises Run -LOTS 1 & 10 REV. PERMIT GENERAL INFORMATION ------------------- Conditioned Floor Area..... 5099 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories.. ..... 1 ' Floor Construction Type.... Slab On Grade Glazing Percentage......... 18.6 % of floor Average Glazing U-factor... 0.4 Btu/hr-sf-F ,area Average Glazing SHGC....... 0:38 Average Ceiling Height..... 16.7 ft BUILDING SHELL INSULATION t Component Frame ----------------------- Cavity--Sheathing--Total--Assembly Total Assembly Type Type R-value R-value R-value U-factor Location/Comments z------------ ------- ----------------------- ------ - Wall Wood ------------------ R-17.8 R-3.9 R-21.7 0.051 ,.: Wall Wood R-17.8 R-0 R-17.8 0.064 Wall Wood R-13 R-0 R-13 0.088 2x4 Studs Door None R-0 R-0 R-0 0.330 RoofRadiant Wood R-11 R-27 R-38 0.025 SlabEdge None R-0 R-0 F2=0.760 SlabEdge None R-0 R-0 F2=0.510 FENESTRATION ------------ Over- Orientation ----------- Area U- Interior (sf) Factor SHGC Shading Exterior Shading hang/ Fins Window Back (S) ----- ------ --------------------- 48.0 0.380 0.350 Standard -------------- Standard ----- Yes Door Right (W) 48.0 0.380 0.350 Standard Standard Yes Door Back (S) 240.0 0.400 0.400 Standard Standard Yes Door Right (W) 120.0 0.400 0.400 Standard Standard Yes Door Back (S) 48.0 0.380 0.350 Standard Standard Yes Window Back (S) 15.0 0.380 0.350 Standard Standard None Window Right (W) 4.0 0.380 0.350 Standard Standard None Window Right (W) 4.0 0.380 0.350 Standard Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Right (W) 13.5 0.380 0.350 Standard Standard None Window Right (W) 13.5 0.380 0.350 Standard Standard None - Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard None CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:01:27 MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin's Enterprises Run -LOTS 1 & 10 REV. PERMIT ----- -------------------------------------------------------------------- FENESTRATION ------------ Over- Orientation --------- -- Area (sf) U- Factor SHGC Interior Shading Exterior Shading hang/ Fins Window Window Right Right (W) ----- 9.0 4.5 ------ 0.380 ------ 0.350 --------------- Standard -------------- Standard -- None f Window Right (W) (W) 4.5 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None Window Left (E) 15.0 0.380 0.350 Standard Standard None None Door Window Left Left (E) (E) 48.0 4.5 0.380 0.380 0.350 0.350 Standard Standard Standard None Window Front (N) 4.5 0.380 0.350 Standard Standard Standard None None j Window Right (W) 17.5 0.380 0.350 Standard Standard None Door Front (N) 24.0 0.380 0.350 Standard Standard None Door Front (N) 24.0 0.380 0.350 Standard Standard None Door Window Front Right (N) 24.0 12.5 0.380 0.350 Standard Standard None Window Right (W) (W) 12.5 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None None Window Window Right Back (W) (S) 12.5 12.5 0.380 0.380 0.350 0.350 Standard Standard Standard None ' Window Left (E) 23.4 0.380 0.350 Standard Standard Standard None None Window Window Left Left (E) (E) 4.5 4.5 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None Window Left (E) 15.0 0.380 0.350 Standard Standard None None Window Window Left Left (E) (E) 15.0 4.5 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None Window Left (E) 13.5 0.380 0.350 Standard Standard None None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Door Window Front Left (N) (E) 48.0 4.5 0.500 0.380 0.500 0.350 Standard Standard Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None None Window Window Front (N) 3.8 0.380 0.350 Standard Standard None Window Front Front (N) (N) 3.8 3.8 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None None r SLAB SURFACES ------------- Area Slab Type ---------------- (sf) Standard Slab ------ 4546 Standard Slab 553 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-lR Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:01:27 MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program -FORM CF-1R User#_MP0207 User-Madlin's Enterprises Run-LOTS-1 & 10 REV. PERMIT ------ HVAC SYSTEMS Refrigerant Tested ACCA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat Type Efficiency Airflow Location R-value Leakage D ' Type -------------------------------------------------------- ------ ---------- Furnace 0.780 AFUE n/a Attic R-4.2 No No Setback ACSp1itTXV 12.00 SEER Yes Attic R-4.2 No No Setback Furnace 0.780 AFUE n/a Attic R-4.2 No No Setback ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No Setback r ` WATER HEATING SYSTEMS I--------------------- Number Tank External +' in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value ------------------------------ ---------------------- ---------- DHW 1 Large Gas Recirc/TimeTemp 1 n/a 75 R-0 DHW 2 Storage Gas Standard 1 0.58 30 R- n/a WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal.Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R-value Light ------------------------ ---------------------- t DHW 1----------------------- Large 0.78 n/a 0.03 R-n/a 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS ---------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** t ***verified during plan check and field inspection. *** i This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). This building incorporates non-standard Water Heating System CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-1R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:01:27 MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program -FORM CF-1R ------User#-MP0207 User-Madlin's Enterprises Run -LOTS 1 & 10 REV. PERMIT HERS REQUIRED VERIFICATION ------------------------ *** Items in this section require - field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** *** must be reported on the CF-6R installation certificate. ***: This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. , i REMARKS This revised calculation reflects updates/changes to glazing -areas and types. The values and materials used in this'compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. ! The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The installing hvac contractor shall provide the required CF=6R with the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the HVAC system. The installed plumber shall provide the required CF-6R li"sting the water heater model number(s) and certified plumbing fixtures. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 5 CF-1R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:01:27 MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program -FORM CF-lR User#-MP0207 User-Madlin's Enterprises Run -LOTS 1 & 10 REV. PERMIT ---------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations . to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, r any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER Name.... Company. CORAL OPTION 1, LLC Address. P.O. BOX 1716 LA QUINTA CA 92253 Phone... 760-7.77- 7 7 License. Signed.. //[ Q ( too ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) r 1 DOCUMENTATION AUTHOR Name.... CATHERINE M. MADLIN Company. Madlin's Enterprises Address. P.O. Box 1443 Palm Springs, CA 92262 Phone... 760-322-5004 Signed.. (date) Certified Energy Analyst Catherine M. Madlin . NR 98.90.544 , r r R 98.90.144 LC r CAA Ccalifomio Assodafion of Building Energy C wlwa COMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:01:27 Project Address........ LOTS 1 & 10 PLAN 6 ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 Climate Zone. ..... 760-322-5004 15 Field C ec --------------------- Date Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program -FORM C-2R -User#-MP0207 User-Madlin ----- s Enterprises Run -LOTS 1 & 10 REV. PERMIT = MICROPAS6 ENERGY USE SUMMARY = ------------------------P-- = Energy Use Standard Proposed Compliance _ _ (kBtu/sf-yr) ------------------ Design Design Margin = = Space Heating.......... --------- 4.26 ------- 4 .15 --- _ 0.11 = = Space Cooling.......... 37.50 32.32 5.18 = = Water Heating.......... 5.59 7.51 -1.92 _ _ North Total ---------------- 47.35 -------- 43.98 _ 3.37 = = Space Heating.......... 4.26 4.12 0.14 = _ Space Cooling.......... 37.50 32.36 5.14 _ = Water Heating.......... 5.59 7.51 -1.92, _ East Total -------- -------- 47.35 -------- 43.99 3.36 = Space Heating.......... 4.26 4.08 0.18 = = Space Cooling.......... 37.50 32.96 .4.54 = = Water Heating.......... 5.59 7.51 -1.92 = South Total -------- -------- 47.35 -------- 44.55 2.80 = Space Heating.......... 4.26 3.92 0.34 = = Space Cooling.......... 37.50 32.09 5.41 = = Water Heating........... 5.59 7.51 -1.92 = = West Total ---------------- 47.35 -------- 43.52 _ 3.83 = _ *** Building complies --------------- with Computer Performance • GENERAL INFORMATION ------------------ Conditioned Floor -Area ..... 5099 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 0 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number,of Building Zones... 2 COMPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14.01.27 MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -LOTS 1 & 10 REV. PERMIT ----- -------------=------------------------------------------------------ Conditioned Volume......... 54407 cf Slab -On -Grade Area......... 5099 sf Glazing Percentage......... 18.6 % of floor area Average Glazing U-factor... 0.4 Btu/hr-sf-F Average Glazing SHGC....... 0.38 Average Ceiling Height..... 10.7 ft Zone Type i 1. ZONE Residence S 2.ZONE Residence BUILDING ZONE INFORMATION ------------------------- Floor # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage (sf) (cf) Units itioned Type (ft) (sf) Credit ------------ ----------------------- ---------------------- 4546 48877 0.89 Yes Setback 2.0 Standard ' No 553 5530 0.11 Yes Setback 2.0 Standard No OPAQUE SURFACES Area U- --------------- Insul Act Solar Form 3 Surface -------------- (sf) factor R-val Azm Tilt Gains Reference 1.ZONE ------ ----- ----- --- ---- ----- N ------------ 1 Wall 510 0.051 21.7 0 90 Yes W.17.8.PW2X6 3 Wall 1353 0.051 21.7 90 90 Yes W.17.8.PW2X6 5 Wall 601 0.051 21.7 180 90 Yes W.17.8.PW2X6 7 Wall 1054 0.051 21.7 270 90 Yes W.17.8.PW2X6 9 Wall 331 0.064 17.8 0 90 No W.19.2X6FIRE 11 Wall 90 0.088 13 0 90 No W.13.2X4.16 13 Door 24 0.330 0 0 90 No None 14 RoofRadiant 4541 0.025 38 n/a 0 Yes R.38.2X4.24 2.ZONE 2 Wall 180 0.051 21.7 0 90 Yes W.17.8.PW2X6 4 Wall 302 0.051 21.7 90 90 Yes W.17.8.PW2X6 6 Wall 155 0.051 21.7 180 90 Yes W.17.8.PW2X6 8 Wall 330 0.051 21.7 270 90 Yes W.17.8.PW2X6 10 Wall 65 0.064 17.8 0 90 No W.19.2X6FIRE 12 Door 24 0.330 0 135 90 Yes None 15 RoofRadiant 553 0.025 38 n/a 0 Yes R.38.2X4.24 PERIMETER LOSSES Location/ Comments ---------------- 2x4 Studs Length F2 Insul Solar Surface ------------ (ft) ------ Factor R-val Gains Location/Comments 1.ZONE -------- ------- ----- ---------------------- 16 SlabEdge 369 0.760 R-0 No 18 SlabEdge 35 0.510 R-0 No 2.ZONE 17 SlabEdge 109 0.760 R-0 No 19 SlabEdge 7 0.510 R-0 No COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:01:27 MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program -FORM C-2R -User#-MP0207 User-Madlin's Enterprises Run -LOTS 1 & 10 REV. PERMIT ----- ------------------------------------------------------------------ FENESTRATION SURFACES --------------------- Area U- Act Orientation (sf) factor SHGC Azm Tilt ---------------------- ----- ----- ----- --- ---- 1. ZONE 1 Window 2 Door 3 Door 4 Door 5 Door 6 Window 7 Window 8 Window 9 Window 10 Window 11 Window 19 Window 20 Window 21 Window 22 Door 23 Door 24 Door 25 Window 26 Window 27 Window 28 Window 29 Window 30 Window 31 Window 32 Window 33 Window 34 Window 35 Window 36 Skylight 37 Skylight 38 Skylight 39 Skylight 40 Skylight 41 Door 44 Window 45 Window 46 Window 2.ZONE 12 Window 13 Window 14 Window 15 Window 16 Window 17 Window 18 Door 42 Window 43 Window Back (S) 48.0 0.380 0.350 180 90 Right (W) 48.0 0.380 0.350 270 90 Back (S) 240.0 0.400 0.400 180 90 Right (W) 120.0 0.400 0.400 270 90 Back (S) 48.0 0.380 0.350 180 90 Back (S) 15.0 0.380 0.350 180 90 Right (W) 4.0 0.380 0.350 270 90 Right (W) 4.0 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 13.5 0.380 0.350 270 90 Right (W) 13.5 0.380 0.350 270 90 Left (E) 4.5 0.380 0.350 90 90 Front (N) 4.5 0.380 0.350 0 90 Right (W) 17.5 0.380 0.350 270 90 Front (N) 24.0 0.380 0.350 0 90 Front (N) 24.0 0.380 0.350 0 90 Front (N) 24.0 0.380 0.350 0 90 Right (W) 12.5 0.380 0.350 270 90 Right (W) 12.5 0.380 0.350 270 90 Right (W) 12.5 0.380 0.350 270 90 Back (S) 12.5 0.380 0.350 180 90 Left (E) 23.4 0.380 0.350 90 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 15.0 0.380 0.350 90 90 Left (E) 15.0 0.380 0.350 90 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 13.5 0.380 0.350 90 90 Horz 1.0 1.720 0.830 0 0 Horz 1.0 1.720 0.830 0 0 Horz 1.0 1.720 0.830 0 0 Horz 1.0 1.720 0.830 0 0 Horz 1.0 1.720 0.830 0 0 Front (N) 48.0 0.500 0.500 0 90 Front (N) 3.8 0.380 0.350 0 90 Front (N) 3.8 0.380 0.350 0 90 Front (N) 3.8 0.380 0.350 0 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 9.0 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Left (E) 15.0 0.380 0.350 90 90 Left (E) 48.0 0.380 0.350 90 90 Left (E) 4.5 0.380 0.350 90 90 Left (E) 4.5 0.380 0.350 90 90 Exterior Shade Interior Shade Type/SHGC Type/SHGC ---------------------------- Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 None/l None/l None/l None/l None/l Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 None/l None/l None/1 None/l None/l Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:01:27 MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program -FORM C-2R User#_MP0207 User-Madlin's Enterprises Run -LOTS 1 & 10 REV. PERMIT ------ --------------------------------------------------------------- OVERHANGS AND SIDE FINS ---Window--------Overhan -Left Fin--- ---Right Fin-- � Area Left Rght Surface --- (sf) Wdth Hgth Dpth Hght Ext ----- ----- Ext Ext Dpth Hght Ext Dpth Hght 1.ZONE ---- ---- ---- ---- ---- 1 Window 2 48.0 8 6 1.67 0 n/a n/a n/a n/a n/a n/a n/a n/a Door 48.0 6 8 30 6 n/a n/a n/a n/a n/a n/a n/a n/a 3'Door 240.0 22 12 17 2 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 120.0 12 12 13 2 n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 48.0 6 8 28 6 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES -------------Area Slab Type (sf) -------- 1.ZONE ------ Standard Slab' 4546 2.ZONE Standard Slab 553 HVAC SYSTEMS , ' System ------------ Refrigerant Minimum Charge and Duct Tested ACCA Duct Duct Manual Duct Efficiency Airflow Location R-value Leakage D Eff ---Type ------- 1.ZONE ----------- -------------------- ------------------------ ---- Furnace ACSplitTXV 0.780 12.00 AFUE n/a Attic SEER Yes Attic R-4.2 No No R-4.2 No' No 0.743 0.637 2.ZONE Furnace 0.780 AFUE n/a Attic R-4.2 No' No 0.743 ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No 0.637 WATER HEATING SYSTEMS --------------------- Number Tank External Tank Type Heater ---------- Type Distribution Type in Energy Size Insulation System Factor (gal) R-value DHW 1 ------------------- -------------- ---------------- 1 Large Gas Recirc/TimeTemp 1 n/a 75 R-0 DHW 2 2 Storage Gas Standard 1 0.58 30' R- n/a' j • 1 COMPUTER METHOD SUMMARY Page 5 C-2R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:01:27 MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program -FORM C-2R ------User#-MP0207 User-Madlin's Enterprises Run -LOTS 1 & 10 REV. PERMIT ---------------------------------------------------------------------- WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R-value Light ------------------------------------------------------------- ------- DHW 1 1 Large 0.78 n/a 0.03 R-n/a 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS f----------------------------------------- *** *** Items in this section should be documented on the plans, *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS This revised calculation reflects updates/changes to glazing areas and types. The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. 'The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in s I f COMPUTER METHOD SUMMARY Page 6 C-2R ------------------------ ______ _g_ _ -------------------------------------- Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:01:27 MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program -FORM C-2R -User#-MP0207 User-Madlin s Enterprises Run -LOTS 1 & 10 REV. PERMIT ----- ---------------------------------------------------------------- REMARKS accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, ?eople and a fixed latent heat gain percentage. This basic Load must be adjusted for additional design conditions and system/equipment performance. Che installing hvac contractor shall provide the required CF-6R with the installed hvac equipment model numbers. k night setback thermostat is required to be installed with the iVAC system. Che installed plumber shall provide the required CF-6R listing :he water heater model number(s) and certified plumbing :ixtures. Madlin -s enteyprzses Catherine M. Madlin, Cerlified Energy Analyst . 760-322-5004 / 323-3644 (fax) .... V S V Andalusia at Coral Mountain Series 75 Plan 6 - Lot 4 - NVo Guest House CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:02:27 Project Address........ LOT 4 PLAN 6 w/o GH ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. _________________________ -----MICROPAS6 v6.01 File-24587B1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin's Enterprises Run -LOT 4 REV PERMIT CALC ---------------------------------------------------------------------- GENERAL INFORMATION ------------------- Conditioned Floor Area..... 4526 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 18.8 % of floor area Average Glazing U-factor... 0.4 Btu/hr-sf-F Average Glazing SHGC....... 0.38 Average Ceiling Height...... 10.8 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type Type ---------- R-value -------- R-value R-value U-factor Location/Comments Wall Wood 'Wood R-17.8 ---------------------- R-3.9 R-21.7 0.051 ------------------------ Wall R-17.8 R-0 R-17.8 0.064 Wall Wood R-13 R-0 R-13 0.088 2x4 Studs ' Door None R-0 R-0 R-0 0.330 RoofRadiant Wood R-11 R-27 R-38 0.025 ' SlabEdge None R-0 R-0 F2=0.760 SlabEdge None R-0 R-0 F2=0.510 FENESTRATION ------------ Area U- Interior Exterior Over- hang/ Orientation ---------- (sf) ----- Factor SHGC Shading Shading Fins Window Back (S) ------ 48.0 0.380 --------------------- 0.350 Standard -------------- Standard ---- Yes Door Right (W) 48.0 0.380 0.350 Standard Standard Yes Door Back (S) 240.0 0.400 0.400 Standard Standard Yes Door Right (W) 120.0 0.400 0.400 Standard Standard Yes . Door Back (S) 48.0 0.380 0.350 Standard Standard Yes Window Back (S) 15.0 0.380 0.350 Standard Standard None Window Right (W) 4.0 0.380 0.350 Standard Standard None Window Right (W) 4.0 0.380 0.350 Standard Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Right (W) 13.5 0.380 0.350 Standard Standard None Window Right (W) 13.5 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None Window Front (N) 4.5 0.380 0.350 Standard Standard None CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:02:27 MICROPAS6 v6.01 File-24587B1 Wth-CTZ15S92 Program -FORM CF-1R User#_MP0207 User-Madlin's Enterprises Run -LOT 4 REV PERMIT CALC ------ ----------------------------------------------------------------- FENESTRATION Over - Area U- Interior Exterior hang/ Orientation ----------- (sf) Factor SHGC Shading Shading Fins Window Right (W) ----- 17.5 ------ 0.380 ------ 0.350 --------------- Standard -------------- Standard ----- None Door Front (N) 24.0 0.380 0.350 Standard Standard None Door Front (N) 24.0 0.380 0.350 Standard Standard None Door Front (N) 24.0 0.380 0.350 Standard Standard None Window Right (W) 12.5 0.380 0.350 Standard Standard None Window Right (W) 12.5 0.380 0.350 Standard Standard None Window Right (W) 12.5 0.380 0.350 Standard Standard None Window Back (S) 12.5 0.380 0.350 Standard Standard None Window Left (E) 23.4 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None Window Left (E) 15.0 0.380 0.350 Standard Standard None Window Left (E) 15.0 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None Window Left (E) 13.5 0.380 0.350 Standard Standard None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Skylight Horz 1.0 1.720 0.830 None None None Door Front (N) 48.0 0.500 0.500 Standard Standard None Window ' Front (N) 4.5 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None SLAB SURFACES ------------- Area Slab Type ---------------- (sf) Standard Slab ------ 4526 HVAC SYSTEMS ------------ Refrigerant Tested ACCA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat ---Type----- Efficiency ----------- Airflow ------------------ Location R-value Leakage D Type Furnace 0.780 AFUE n/a Attic ------- R-4.2 ------- ------ No No ---------- Setback ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No Setback WATER HEATING --------------------- SYSTEMS Number Tank External Tank Type ------------ -Heater ----------- Type Distribution in Type System Energy Size Factor (gal) Insulation R-value DHW 1 . ------------------- -------------- ------ ---------- Large Gas Recirc/TimeTemp 1 n/a 75. R-0 DHW 2 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-lR Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:02:27 MICROPAS6v6�01--File-24587B1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin's Enterprises Run -LOT 4 REV PERMIT CALC ----- - ------------------------------------------------------- WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value ------------------------------ -------------- ------ ---------- Storage Gas Standard 1 0.58 30 R- n/a System DHW 1 Large WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss Insulation Pilot Efficiency Input Fraction R-value Light ---------------------------------------------------------- 0.78 n/a 0.03 R-n/a 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions.. This printout is for the front facing North. This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning i system(s). This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION -------------------------- *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS Lot 4 does .not have a guest house. This revised calculation reflects updates/changes to glazing areas and types: CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-1R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:02:27 MICROPAS6 v6.01 File-24587B1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin's Enterprises Run -LOT 4 REV PERMIT CALC REMARKS .The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. l The installing hvac contractor shall provide the required CF-6R with the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the } HVAC system. The installed plumber shall provide the required CF-6R listing the water heater model number(s) and certified plumbing fixtures. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 5 CF-1R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14.02:27 -----MICROPAS6 v6.01 File-24587B1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0207 User-Madlin's Enterprises Run -LOT 4 REV PERMIT CALC ---------------------------------------------------=----------- ---- -- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations,' any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER Name.... Company. CORAL OPTION 1, LLC Address. P.O. BOX 1716 LA QUINTA, CA 92253 Phone... 760-77 7747 License. Signed.. Z11?, Q a e) Name.... Title... Agency.. Phone... Signed.. ENFORCEMENT AGENCY F (date) DOCUMENTATION AUTHOR Name.... CATHERINE M. MADLIN Company. Madlin's Enterprises Address. P.O. Box 1443 Palm Springs, CA 92262 Phone... 760-322-5004 Signed.. (date) !/ jp'ae- Certified Energy Analyst Catherine M. Madlin NR 98.90-544 r r rr R 98-90-144 C A D E C California Association of Building Energy Consultants i i COMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:02:27 Project Address........ LOT 4 PLAN 6 w/o GH ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Bui ing Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone.......... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-24587B1 Wth-CTZ15S92 Program -FORM C-2R ------User#-MP0207 User-Madlin s Enterprises Run -LOT 4 REV PERMIT CALC ------------ --------------- ------------ --------- ------ ------- ------------ _ MICROPAS6 ----------------------------------- ENERGY USE SUMMARY = ------------------------P-- = Energy Use Standard =_ Proposed'Compliance _ (kBtu/sf-yr) . ------------- Design ---------- Design Margin = = Space Heating.......... 3.81 ------ 3.68 ---- - 0.13 = _ Space Cooling.......... 36.14 30.48 5.66 = = Water Heating.......... 6.30 8.46 -2.16 = = North Total -------- 46.25 ---------------- 42.62 _ 3.63 = = Space Heating.......... 3.81 3.76 0.05 = = Space Cooling.......... 36.14 30.91 5.23 = = Water Heating.......... 6.30 8.46 -2.16 = East Total -------- 46.25 -------- -------- 43.13 3.12 = Space Heating.......... 3.81 3.59 0.22 = _. Space Cooling.......... 36.14 31.22 4.92 = = Water Heating.......... 6.30 8.46 -2.16 = = South Total -------- 46.25 ---------------- 43.27 _ 2.98 _ Space Heating.......... 3.81 3.36 0.45 = = Space Cooling.......... 36.14 31.01 5.13 = = Water Heating.......... 6.30 8.46 -2.16 = West Total -------- 46.25 -------- -------- 42.83 3.42 _ *** Building complies with Computer Performance GENERAL INFORMATION ------------------- Conditioned Floor Area..... 4526 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 .Weather Data Type.......... FullYear Floor Construction Type...'. Slab On Grade Number of Building Zones..., 1 r COMPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14.02.27 -----MICROPAS6 v6.01 File-24587B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -LOT 4 REV PERMIT CALC ----------------------------------------------------- Conditioned Volume......... 48877 cf Slab -On -Grade Area......... 4526 sf Glazing Percentage......... 18.8 % of floor area Average Glazing U-factor... 0.4 Btu/hr-sf-F Average Glazing SHGC....... 0.38 Average Ceiling Height..... 10.8 ft BUILDING ZONE INFORMATION Floor # of I Vent Vent Air. Area Volume Dwell Cond- Thermostat Height Area Leakage Zone Type (sf) (cf) -------------- ------------ Units itioned Type (ft) (sf) Credit, 1.ZONE ----------------------- Residence 4526 48877 1.00 Yes Setback 2.O Standard No OPAQUE SURFACES Area ' U- Insul Act Solar Form 3 Location/ Surface i-------------- (sf) ------ factor ----- R-val Azm Tilt Gains Reference Comments 1.ZONE ----- --- ---- ----- ------------ ---------------- 1 Wall 517 0.051 21.7 0 90 Yes W.17.8.PW2X6 2 Wall 1349 0.051 21.7 90 90 Yes W.17.8.PW2X6 3 Wall 601 0.051 21.7 180 90 Yes W.17.8.PW2X6 4 Wall 1054 0.051 21.7 270 90 Yes W.17.8.PW2X6 5 Wall 331 0.064 17.8 0 90 No W.19.2X6FIRE 6 Wall 90 0.088 13 0 90 No W.13.2X4.16 2x4 Studs 7 Door 24 0.330 0 0 90 No None 8 RoofRadiant 4521 0.025 38 n/a 0 Yes R.38.2X4.24 Length Surface (ft) --- ------ 1.ZONE 9 S1abEdge 369 10 SlabEdge 35 PERIMETER LOSSES ---------------- F2 Insul Solar Factor R-val Gains Location/Comments -------------- --------------------------- 0.760 R-0 No 0.510 R-0 No FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade Orientation -(sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC ------------ -- ----- ----- --- ------------------ -------------- 1.ZONE 1 Window Back (S) 48.0 0.380 0.350 180 90 Standard/0.76 Standard/0.68 2 Door Right (W) 48.0 0.380 0.350 270 90 Standard/0.76 Standard/0.68 3 Door Back (S) 240.0 0.400 0.400 180 90 Standard/0.76 Standard/0.68 4 Door Right (W) 120.0 0.400 0.400 270 90 Standard/0.76 Standard/0.68 5 Door Back (S) 48.0 0.380 0.350 180 90 Standard/0.76 Standard/0.68 6 Window Back (S) 15.0 0.380 0.350 180 90 Standard/0.76 Standard/0.68 7 Window Right (W) 4.0 0.380 0.350 270 90 Standard/0.76 Standard/0.68 8 Window Right (W) 4.0 0.380 0.350 270 90 Standard/0.76 Standard/0.68 9 Window Right (W) 4.5 0.380 0.350 270 90 Standard/0.76 Standard/0.68 10 Window Right (W) 13.5 0.380 0.350 270 90 Standard/0.76 Standard/0.68 COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:02:27 MICROPAS6 v6.01 File-24587B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin s Enterprises Run -LOT 4 REV PERMIT CALC ------ ------------------------------------------------------------------------- FENESTRATION SURFACES Orientation ------------ Area (sf) ----- U- factor SHGC ----- Act Azm Tilt Exterior Shade Type/SHGC Interior Shade Type/SHGC 11 Window Right (W) 13.5 0.380 ----- 0.350 --- 270 ---- 90 -------------- Standard/0.76 -------------- Standard/0.68 12 Window Left (E) 4.5 0.380 0.350 90 90 Standard/0.76 Standard/0.68 13 Window Front (N) 4.5 0.380 0.350 0 90 Standard/0.76 Standard/0.68 14 Window Right (W)- 17.5 0.380 0.350 270 90 Standard/0.76 Standard/0.68 15 ! 16 Door Front (N) 24.0 0.380 0.350 0 90 Standard/0.76 Standard/0.68 Door Front (N) 24.0 0.380 0.350 0 90 Standard/0.76 Standard/0.68 17 Door Front (N) 24.0 0.380 0.350 0 90 Standard/0.76 Standard/0.68 18 Window Right (W) 12.5 0.380 0.350 270 90 Standard/0.76 Standard/0.68 19 Window Right (W) 12.5 0.380 0.350 270 90 Standard/0.76 Standard/0.68 20 Window Right (W) 12.5 0.380 0.350 270 90 Standard/0.76 Standard/0.68 21 Window Back (S) 12.5 0.380 0.350 180 90 Standard/0.76 Standard/0.68 22 Window Left (E) 23.4 0.380 0.350 90 90 Standard/0.76 Standard/0.68 23 Window Left (E) 4.5 0.380 0.350 90 90 Standard/0.76 Standard/0.68 24 Window Left (E) 4.5 0.380 0.350 90 90 Standard/0.76 Standard/0.68 25 Window Left (E) 15.0 0.380 0.350 90 90 Standard/0.76 Standard/0.68 26 Window Left (E) 15.0 0.380 0.350 90 90 Standard/0.76 Standard/0.68 27 Window Left (E) 4.5 0.380 0.350 90 90 Standard/0.76 Standard/0.68 28 Window Left (E) 13.5 0.380 0.350 90 90 Standard/0.76 Standard/0.68 29 Skylight Horz 1.0 1.720 0.830 0 0 None/1 None/1 30 Skylight Horz 1.0 1.720 0.830 0 0 None/1 None/1 31 Skylight Horz 1.0 1.720 0.830 0 0 None/1 None/1 32 Skylight Horz 1.0 1.720 0.830 0 0 None/1 None/1 i 33 Skylight Horz 1.0 1.720 0.830 0 0 None/1 None/1 34 Door Front (N) 48.0 0.500 0.500 0 90 Standard/0:76 Standard/0.68 35 Window Front (N) 4.5 0.380 0.350 0 90 Standard/0.76 Standard/0.68 36 Window Left (E) 4.5 0.380 0.350 90 90 Standard/0.76 Standard/0.68 OVERHANGS AND SIDE FINS ---Window-- ----------------------- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface - (sf) ----- Wdth ----- Hgth ----- Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght 1.ZONE ---- ---- ---- ---- ---- 1 Window 48.0 8 6 1.67 0 n/a n/a n/a n/a n/a n/a n/a n/a 2 Door 48.0 6 8 30 6 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 240.0 22 12 17 - 2 n/a n/a n/a n/a n/a n/a n/a n/a E 4 Door 120.0 12 12 13, 2 n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 48.0 6 8 28 6 n/a n/a n/a n/a n/a n/a n/a n/a SLAB ------------- SURFACES Area Slab Type (sf) 1.ZONE ------- ------ Standard Slab 4526 COMPUTER METHOD SUMMARY Page 4 C-2R __________________________ Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:02:27 MICROPAS6 v6.01--File-24587B1 Wth-CTZ15S92 Program -FORM C-2R ------User#_MP0207 User-Madlin s Enterprises Run_LOT-4- REV -PERMIT CALC --------------- ---------------------- HVAC SYSTEMS ------------ Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type Efficiency Airflow Location R-value Leakage ----------- D- Eff 1.ZONE -------------------------------------=------ ---- Furnace 0.780 AFUE n/a Attic R-4.2 No No 0.743 ACSplitTXV 12.00 SEER Yes Attic R-4.2 No i No 0.637 WATER HEATING SYSTEMS --------------------- Number Tank External Tank Type ------------ in Energy Size Heater Type Distribution Type System Factor (gal) ------------------------------ Insulation R-value DHW 1 --------------------- ---------- ! 1 Large Gas Recirc/TimeTemp 1 n/a 75 R-0 DHW 2 2 Storage Gas Standard 1 0.58 30 R- n/a WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R-value Light DHW 1 + 1 Large 0.78 n/a 0.03 R-n/a- 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans,'*** *** installed to manufacturer and CEC specifications, and *** i *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the' roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning', system(s). ' This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under ***' *** the supervision of a CEC-approved HERS provider.using *** COMPUTER METHOD SUMMARY Page 5 C-2R Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14.02.27 ------MICROPAS6 v6.01 File-24587B1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -LOT 4 REV PERMIT CALC -------------------------------------------------------------------- HERS REQUIRED VERIFICATION -------------------------- *** CEC approved testing and/or verification methods.and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS Lot 4 does not have a guest house. This revised calculation reflects updates/changes to glazing areas and types. The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and . equipment selection(s)'. The HVAC design shall be done in accordance with industry standards. The load calculation,in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The installing hvac contractor shall provide the required CF-6R ' with the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the HVAC system. The installed plumber shall provide the required CF-6R listing the,water heater model number(s) and certified plumbing fixtures. ,M i ain s enterpfises Catherine M. Madlin, Certified EyzeiV Analyst v 760-322-5004 / 323-3644 (fax) V ... V V,. a a a v e ° 0 ° H. V.A. C. Load Calculation Madlin-'s enterprises Catherine M. Madlin, Certified Enemy Analyst • 760-322-5004 / 323-3644 (fax) ..' .. t v . Andalusia at Coral Mountain Series 75 - Plan 4 HVAC SIZING Page 1 HVAC Project Title.......... ANDALUSIA.PLAN.4 Date..11/09/04 13:54:57 Project Address........ PLAN 4 ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M.-MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone........... 15 Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ________________________ -----MICROPAS6 v6.01 File-24575B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ---------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area ................. Volume.. 3933 sf ........... Front Orientation.......... 42912 cf Front Facing 0 deg (N) Sizing Location............ INDIO Latitude ................... Winter Outside Design...... 33.7 degrees 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. .. .. ..... Interior Shading Used...... 30 F No Exterior Shading Used...... No Overhang Shading Used...... No ' Latent Load Fraction....... 0.20 HEATING AND COOLING -------------------------------- LOAD SUMMARY Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ---------------------- 25382 9445 Glazing Conduction ............... 12459 10332 Glazing Solar .................... Infiltration n/a 14869 ..................... Internal Gain 25304 14996 .................... Ducts. n/a 3051 .................... Sensible Load .................... 6314 69459 5269 57963 Latent Load ...................... n/a 11593 Minimum Total Load ---------------------- 69459 69555 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 2 HVAC _______________________----------------- ----------------- Project Title.......... ANDALUSIA.PLAN.4 Date..11/09/04 13.54:57 MICROPAS6 v6.01 File-24575B1 Wth-CTZ15S92 Program-HVAC SIZING --------User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----------------------------------------------------------------- HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE '1.ZONE' Floor Area.. ................... 3429 sf Volume ........................... 37872 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 20045 ----------- 7674 Glazing Conduction ............... 11262 9339 Glazing Solar... ................. Infiltration n/a 13366 ..................... Internal Gain 22332 13234 .................... Ducts n/a 2915 ............................ 5364 4653 Sensible Load .................... 59002 51181 Latent Load ..................... n/a 10236 Minimum Zone Load ----------- 59002 ----------- 61417 ZONE 12.ZONE'' Floor Area..... .................. Volume............................ 504 sf 5040 cf Heating Cooling Description --------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 5337 ----------- 1771 Glazing Conduction ............... 1197 993, Glazing Solar..... ............. Infiltration n/a 1503 ..................... Internal Gain....... 2972 1761 ............. Ducts............................ n/a 137 951 616 Sensible Load.................... 10457 6781 Latent Load ...................... n/a 1356 - Minimum Zone Load ----------- 10457 ----------- 8138 HVAC SIZING Page 3 HVAC Project Title.......... ANDALUSIA.PLAN A Date..11/09/04 13:54:57 MICROPAS6 v6.01 File-24575B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----- GENERAL INFORMATION ------------------- FloorArea ................. 3933 Volume.. .... 42912 Front Orientation.......... Front Sizing Location.,........... INDIO Latitude... ....... 33.7 Winter Out, Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 sf cf Facing 90 deg (E) degrees HEATING AND COOLING -------------------------------- LOAD SUMMARY Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 25382 ----------- 9445 Glazing Conduction ............... 12459 10332 Glazing Solar .................... Infiltration n/a 19725 ..................... Internal Gain...... 25304 14996 .............. Ducts. n/a 3051 .................... Sensible Load 6314 5755 .................... Latent Load 69459 63304 ...................... n/a 12661 Minimum Total Load ----------- 69459 ----------- 75964 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING ----------------------------- Page 4 HVAC Project Title.......... ANDALUSIA.PLAN.4 Date..11/09/04 13:54:57 MICROPAS6 v6.01 File-24575B1 Wth-CTZ15S92 Program-HVAC SIZING --------User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------------------------------------------------------------------- HEATING AND COOLING LOAD ---------------------------------------- SUMMARY BY ZONE ZONE '1.ZONE' Floor Area....................... 3429 sf Volume ........................... 37872 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 20045 ----------- 7674 Glazing Conduction ............... 11262 9339 Glazing Solar.................... Infiltration n/a 18057 ..................... Internal Gain .................... 22332 13234 Ducts n/a 2915 ............................ 5364 5122 Sensible Load .................... 59002 56341 Latent Load ...................... "n/a 11268 Minimum Zone Load ----------- 59002 ----------- 67610 ZONE 12.ZONE' Floor Area .................... Volume.......... ... 504 sf ......... 5040 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 5337 ----------- 1771 Glazing Conduction ............... 1197 993 Glazing Solar .................... Infiltration n/a 1667 ..................... Internal Gain 2972 1761 .................... Ducts............................ n/a 137 951 633 Sensible Load .................... 10457 6962 Latent Load ...................... n/a 1392 Minimum Zone Load ----------- 10457 ----------- 8355 HVAC SIZING Page 5 HVAC Project Title.......... ANDALUSIA.PLAN.4 Date..11/09/04 13.54.57 MICROPAS6 v6.01 File-24575B1 Wth-CTZ15S92 Program-HVAC SIZING -User#-MP0207 User=Madlin's Enterprises Run -REVISED PERMIT CALC ------- ------------------------------------------------------------------ GENERAL INFORMATION Floor Area ................. 3933 sf Volume.. .... ........... 42912 cf Front Orientation.......... Front Facing Sizing Location............ INDIO Latitude .............. 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range. ..... ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Heating Description --------------------------------- (Btuh) Opaque Conduction and Solar...... ----------- 25382 Glazing Conduction ............... 12459 Glazing Solar .................... n/a Infiltration ..................... 25304 Internal Gain .................... Ducts. n/a .................... Sensible Load 6314 69459 .................... Latent Load ........:............. n/a Minimum Total Load 69459 180 deg (S) Cooling (Btuh) 9445 10332 12242 14996 3051 5007 55073 11015 66088 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 6 HVAC Project Title.......... ANDALUSIA.PLAN.4 Date..11/09/04 13:54:57 MICROPAS6v601--File-24575B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----- - ---------------------------------------------------- HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE '1.ZONE' Floor Area ............... 3429 sf Volume ........................... 37872 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 20045 ----------- 7674 Glazing Conduction ............... 11262 9339 Glazing Solar ................... Infiltration n/a 11087 ..................... Internal Gain 22332 13234 .................... Ducts. n/a 2915 .......................... 5364 4425 Sensible Load .................... 59002 48674 Latent Load ...................... n/a 9735 ----------- Minimum Zone Load 59002 ----------- 58409 ZONE 12.ZONE' Floor Area...___________ rnn �.9 - --- - - - - - ' ' . . . . . . . . . . . . . Volume........................... ✓ V J 1 5040 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 5337 ----------- 1771 Glazing Conduction ............... 1197 Glazing Solar .................... n/a .993 1155 Infiltration ..................... Internal Gain 2972 1761 .................... Ducts....... n/a 137 ................... 951 582 Sensible Load............ ...... 10457 6399- Latent Load ...................... n/a 1280 Minimum Zone Load ----------- 10457 ----------- 7679 HVAC SIZING Page 7 HVAC Project Title.......... ANDALUSIA.PLAN A Date..11/09/04 13:54:57 -----MICROPAS6v6- 01-File-24575B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin s Enterprises Run -REVISED PERMIT CALC - -------------------- ------------- ------- ----- ------- GENERAL INFORMATION Floor Area................. 3933 sf Volume.. .... ........... 42912 cf Front Orientation.......... Front Facing Sizing Location............ INDIO Latitude .............. 33.7 degrees Winter Outside Design...., 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range. ..... ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Heating Description --------------------------------- (Btuh) Opaque Conduction and Solar...... ----------- 25382 Glazing Conduction ............... 12459 Glazing Solar .................... Infiltration n/a ..................... Internal Gain 25304 .................... Ducts. n/a .... ................... Sensible Load 6314 .................... LatentLoad...... 69459 . ............ n/a Minimum Total Load 69459 270 deg (W) Cooling (Btuh) 9445 10332 20238 14996 3051 5806 63868 12774 76642 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 8 HVAC ---------------------------------------- Project Title.......... ANDALUSIA.PLAN.4 Date..11/09/04 13:54:57 MICROPAS6 v6.01 File-24575B1 Wth-CTZ15S92 Program-HVAC SIZING --------User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ---------------------------------------------------------- HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE '1.ZONE' Floor Area ....................... 3429 sf Volume ........................... 37872 cf Description Heating Cooling --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 20045 ----------- 7674 Glazing Conduction............... Glazing Solar 11262 9339 .................... Infiltration......... n/a 18373 ... ...... Internal Gain .................... 22332 13234 Ducts n/a 2915 ............................ 5364 5154 Sensible Load .................... 59002 56689 Latent Load ...................... n/a 11338 ----------- Minimum Zone Load 59002 ----------- 68026 ZONE '2.ZONE' Floor Area .................... 504 sf Volume........................... 5040 cf Heating Cooling Description ---------------------- (Btuh) (Btuh) Opaque Conduction and Solar...:.. ----------- 5337 ----------- 1771 Glazing Conduction ............... Glazing Solar 1197 993 .................... Infiltration n/a 1865 ..................... Internal Gain 2972 1761 .................... Ducts.. n/a 137 ........................ _ 951 653 Sensible Load .................... 10457 7180 Latent Load ...................... n/a 1436 ----------- Minimum Zone Load 10457 ----------- 8616 Madlin-'s enterprises Catherine M. Madlin, Certified Enemy Analyst v 760-322-5004 / 323-3644 (fax) . V V . V . S Andalusia at Coral Mountain Series 75 Plan 4 with Dining Room Option HVAC SIZING Page 1 HVAC Project Title.......:.. ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13:56:10 Project Address........ PLAN 4 w DINING RM OPT ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program-HVAC SIZING -User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------- ------------------------------------------------------------------=-- GENERAL INFORMATION ------------------- Floor Area ................. Volume.. 3907 sf , ........... Front Orientation.......... 42912 cf Front Facing 0 deg (Ni Sizing Location............ INDIO Latitude.. . ' Winter Outside Design 33.7 degrees 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range. ..... ..... 30 F i Interior Shading Used...... No j Exterior Shading Used...... No Overhang Shading Used...... No S Latent Load Fraction....... 0.20 HEATING AND COOLING -------- ----------------------- LOAD SUMMARY ! Description --------------------------------- (Btuh)g (Btuh)g Opaque Conduction and Solar...... ---------------------- 25303 9389 Glazing Conduction ............... 12818 10629 Glazing Solar .................... Infiltration n/a 15570 ..................... Internal Gain .................... 25304 n/a 14996 3051 Ducts ...... ....... ......... 6342 5363 Sensible Load .. 69766 58998 Latent Load ...................... n/a 11800 Minimum Total Load ---------------------- 69766 70798 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all .factors when selecting the HVAC equipment. HVAC SIZING Page 2 HVAC Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13.56.10 -----MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program-HVAC SIZING --User#-MP0207 User-Madlin s Enterprises Run -REVISED PERMIT CALC --------------------------------------------------------------------- HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE '1.ZONE' Floor Area ....................... 3403 sf Volume ........................... 37872 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 19966 ----------- 7618 Glazing Conduction ............... 11620 9636 Glazing Solar .................... Infiltration n/a 14067 ..................... Internal Gain 22332 13234 .................... Ducts n/a 2915 ............................ 5392 4747 Sensible Load .................... 59309 52217 Latent Load ................. n/a 10443 Minimum Zone Load i ----------- 59309 ----------- 62660 ZONE 12.ZONE' Floor Area ....................... Volume....... 504 sf .................. 5040 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 5337 ----------- 1771 Glazing Conduction ............... 1197 993 Glazing Solar .................... n/a 1503 Infiltration ..................... 2972 1761 Internal Gain .................... n/a 137 Ducts..... ..................... 951 616 Sensible Load .................... 10457 6781 Latent Load ...................... n/a 1356 Minimum Zone Load ----------- 10457 ----------- 8138 HVAC SIZING Page 3 HVAC Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13:56:10 MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program-HVAC SIZING ------_User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC -------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area................. 3907 sf Volume.. .... ........... 42912 cf Front Orientation.......... Front Facing 90 deg (E) Sizing Location............ INDIO Latitude............ Winter Outside Design...... 33.7 degrees 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. ..... ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING -------------------------------- LOAD SUMMARY Heating Cooling Description --------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ---------------------- 25303 9389 GlazingConduction .... 12818 10629 Glazing Solar .................... Infiltration n/a 19869 ..................... Internal Gain .................... 25304 n/a 14996 3051 Ducts ............................ 6342 5793 Sensible Load .................... 69766 63727 Latent Load ...................... n/a 12745 Minimum Total Load ---------------------- 69766 76472 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered.' It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 4 HVAC Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13:56:10 MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE '1.ZONE' i Floor Area ....................... 3403 sf Volume ........................... 37872 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 19966 ----------- 7618 Glazing Conduction ............... 11620 9636 Glazing Solar .................... Infiltration n/a 18201 ..................... Internal Gain 22332 13234 .................... Ducts n/a 2915 ............................ 5392 5160 Sensible Load .................... 59309 56765 Latent Load ...................... n/a 11353 Minimum Zone Load ----------- 59309 ----------- 68118 ZONE 12.ZONE' Floor Area........ ............... Volume 504 sf ........................... 5040 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 5337 ----------- 1771 Glazing Conduction ............... 1197 993 Glazing Solar .................... Infiltration n/a 1667 ..................... Internal Gain 2972 1761 .................... Ducts n/a 137 ............................ 951 633 Sensible Load.................... 10457 6962 Latent Load.... .................. n/a 1392 Minimum Zone Load ----------- 10457 ----------- 8355 HVAC SIZING Page 5 HVAC Project Title.......... ANDALUSIA.PLAN4.wDR.OPT--------Date__11/09/04 13:56.10 MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program-HVAC SIZING --------User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC -------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area ................. 3907 sf Volume.. ........... 42912 cf Front Orientation.......... Front Facing Sizing Location............ INDIO Latitude ............... 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range. ...... ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Heating Description. --------------------------------- (Btuh) Opaque Conduction and Solar...... ----------- 25303 Glazing Conduction ............... 12818 Glazing Solar..... ............... Infiltration n/a ..................... Internal Gain 25304 n/a .................... Ducts. ..... ................... Sensible Load .................... 6342 69766 Latent Load ...................... n/a Minimum Total Load 69766 180 deg (S) Cooling (Btuh) 9389 10629 12943 14996 3051 5101 56109 11222 67331 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, -etc., must also be considered. it is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 6 HVAC Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13:56:10 MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------------------------------------------------------------------------------- HEATING AND COOLING LOAD SUMMARY BY, ZONE ---------------------------------------- ZONE '1.ZONE' Floor Area ......................... Volume 3403 sf ........................... 37872 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 19966 ----------- 7618 Glazing Conduction ............... 11620 9636 Glazing Solar.. ................ Infiltration n/a 11788 ..................... Internal Gain 22332 13234 .................... Ducts n/a 2915 ............................ 5392 4519 Sensible Load .................... 59309 49710 Latent Load ...................... n/a 9942 Minimum Zone Load ----------- 59309 ----------- 59652 ZONE 12.ZONE' Floor Area ....................... Volume........................... 504 sf 5040 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 5337 ----------- 1771 Glazing Conduction............ 1197 993 Glazing Solar .................... n/a 1155 Infiltration.. .................. 2972 1761 Internal Gain. ................... n/a 137 Ducts............................ 951 582 Sensible Load .................... 10457 6399 Latent Load ...................... n/a 1280 Minimum Zone Load ----------- 10457 ----------- 7679 HVAC SIZING Page 7 HVAC Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13:56:10 MICROPAS6 v6.01 File-24576B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area ................. 3907 sf Volume....... . 42912 cf .. Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ INDIO Latitude ................ 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F SummerRange........ ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY- -------------------------------- Description -------------------- Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... InternalGain .................... Ducts. ... ................... Sensible Load .................... LatentLoad ...................... Heating (Btuh) 25303 12818 n/a 25304 n/a 6342 69766 n/a Cooling (Btuh) 9389 10629 20545 14996 3051 5861 64471 12894 ---------------------- Minimum Total Load 69766 77365 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other. relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 8 HVAC -------------------------------------- ___________________________________________________________ Project Title.......... ANDALUSIA.PLAN4.wDR.OPT Date..11/09/04 13.56.10 ------MICROPAS6v601- File-24576B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC - --------------------------------------------------------- HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE '1.ZONE' Floor Area.. ..................... 3403 sf Volume ........................... 37872 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 19966 ----------- 7618 Glazing Conduction ............... 11620 9636 Glazing Solar .................... Infiltration n/a 18680 ..................... Internal Gain 22332 13234 .................... Ducts... n/a 2915 ....................... 5392 5208 Sensible Load .................... 59309 57291 Latent Load ...................... n/a 11458 Minimum Zone Load ----------- 59309 ----- ------ 68750 ZONE 12.ZONE' Floor Area ....................... Volume 504 sf ........................... 5040 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 5337 ----------- 1771 Glazing Conduction ............... Glazing Solar 1197 993 ................... Infiltration n/a 1865 ..................... Internal Gain 2972 1761 .................... Ducts....... n/a 137 ..................... 951 653 Sensible Load .................... 10457 7180 Latent Load ...................... n/a 1436 Minimum Zone Load ----------- 10457 ----------- 8616 Madlin-'s enterprises Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) Andalusia at Coral Mountain Series 75 - Plan 5 HVAC SIZING Pa e'l HVAC ------------------------------ ------------------------------------ Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:57:27 Project Address........ PLAN 5 ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone........... 15 Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. -----MICROPAS6v6- 01-File-24580B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC - ----------------- ------------- ------- ----- ------- GENERAL INFORMATION ------------------- Floor Area ................. 4314 sf Volume.. .. ........... 46404 cf Front Orientation.......... Front Facing 0 deg (N) Sizing Location............ INDIO Latitude....... .... 33.7 degrees Winter Outside Design 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range. .. .. ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY -------------------------------- Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 27570 ----------- 9839 Glazing Conduction. .............. 12628 10472 Glazing Solar .................... Infiltration n/a 13989 ..................... Internal Gain 27363 16216 .................... Ducts. n/a 3097 .................... Sensible Load 6756 5361 .................... Latent Load 74316 58973 ...................... n/a 11795 ----------- Minimum Total Load 74316 ----------- 70768 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 2 HVAC -------------------------------------------------------- Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:57:27 MICROPAS6 v6.01 File-24580B1 Wth-CTZ15S92 Program-HVAC SIZING --------User#_MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC --------------------- ------------ ------------- ------- ----- ------- HEATING AND COOLING LOAD SUMMARY BY ZONE ------------------------------------- ZONE '1.ZONE' Floor Area ....................... Volume........................... 3827 sf 41534 cf Heating Cooling Description ------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 20611 ----------- 7486 Glazing Conduction....:.......... 11490 9528 Glazing Solar .................... Infiltration n/a 12167 ..................... Internal Gain 24491 14514 - .................... Ducts n/a 2982 ............................ 5659 4668 Sensible Load.................... 62252 51345 Latent Load ...................... n/a 10269 Minimum Zone Load ----------- 62252 ----------- 61614 i ZONE 12.ZONE' Floor Area ....................... Volume 487 sf ........................... 4870 cf ' r Heating Cooling Description --------------------------------- .(Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 6959 -- ------- 2353 Glazing Conduction ............... 1137 943 Glazing Solar...... ............ Infiltration n/a 1821 ..................... Internal Gain.. 2872 1702 r Ducts n/a 116 ............................ 1097 693 Sensible Load.................... 12065 7628 Latent Load... ................. n/a 1526 Minimum Zone Load ----------- 12065 ----------- 9153 HVAC SIZING Page 3 HVAC --------------------------------------------------------------- Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:57:27 MICROPAS6 v6.01 File-24580B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area ................. Volume.. 4314 sf .... ........... Front Orientation.......... 46404 cf Front Facing 90 deg (E) Sizing Location............ INDIO Latitude ............... Winter Outside Design...... 33.7 degrees 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range............ 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING -------------------------------- LOAD SUMMARY Heating Cooling Description ---------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ---------------------- 27570 9839 Glazing Conduction ............... 12628 10472 Glazing Solar .................... Infiltration n/a 21411 ..................... Internal Gain 27363 16216 .................... Ducts. n/a 3097 .................... Sensible Load 6756 6103 .................... Latent Load ...................... 74316 n/a 67137 13427 Minimum Total Load ---------------------- 74316 80565 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 4 HVAC Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13.57:27 -----MICROPAS6v601--File-24580B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC - ------------------ ------------- ------- ----- ------- HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE '1.ZONE' Floor Area....................... 3827 sf Volume ........................... 41534 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 20611 ----------- 7486 Glazing Conduction ............... 11490 9528 Glazing Solar.. ................ Infiltration n/a 20227 ..................... Internal Gain 24491 14514 .................... Ducts n/a 2982 ............................ 5659 5474 Sensible Load .................... 62252 60210 Latent Load ...................... n/a 12042. ----------- Minimum Zone Load 62252 ----------- 72253 ZONE '2.ZONE' Floor Area ....................... 487 sf Volume. ..... 4870 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 6959 ----------- 2353. Glazing Conduction ............... 1137 943 Glazing Solar .................... Infiltration n/a 1184 ..................... InternalGain 2872 1702 .................... Ducts n/a 116 ............................ 1097 630 Sensible Load.... .............. 12065 6927 Latent Load ...................... n/a 1385 Minimum Zone Load ----------- 12065 ----------- 8312 HVAC SIZING Page 5 HVAC Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:57:27 MICROPAS6 v6.01 File-24580B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin s Enterprises Run -REVISED PERMIT CALC ------------------------------------------------------------------------ GENERAL INFORMATION Floor Area ................. 4314 sf Volume.. .... ........... 46404 cf Front Orientation.......... Front Facing Sizing Location............ INDIO Latitude ............... 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range. .. .. ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Heating Description --------------------------------- (Btuh) Opaque Conduction and Solar...... ----------- 27570 Glazing Conduction ............... 12628 Glazing Solar .................... n/a Infiltration ..................... Internal Gain .................... 27363 n/a Ducts..' .. ................... Sensible Load .................... 6756 74316 Latent Load ...................... n/a ----------- Minimum Total Load 74316 180 deg (S) Cooling (Btuh), 9839 10472 11724 16216 3097 5135 56482 11296 67779 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 6 HVAC Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13.57.27 -_---MICROPAS6-v6.01 File-24580B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------------------------------------------------------------ HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE '1.ZONE' Floor Area .............. 3827 sf Volume ........................... 41534 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 20611 ----------- 7486 Glazing Conduction ............... 11490 9528 Glazing Solar .................... Infiltration n/a 10033 ..................... Internal Gain... 24491 14514 ................. Ducts n/a 2982 ............................ 5659 4454 Sensible Load .................... 62252 48997 Latent Load ...................... n/a 9799 ----------- Minimum Zone Load 62252 ----------- 58796 ZONE '2.ZONE' Floor Area ............... ....... 487 sf Volume ........................... 4870 cf Heating Cooling Description (Btuh) (Btuh) ------------------------------------------------------- Opaque Conduction and Solar...... 6959 2353 Glazing Conduction ............... 1137 943 Glazing Solar .................... n/a 1692 Infiltration ..................... 2872 1702 Internal Gain .................... n/a 116 Ducts ............................ 1097 680 Sensible Load.... .............. 12065 7485 Latent Load ...................... n/a 1497 ---------------------- Minimum Zone Load 12065 8983 HVAC SIZING Page 7 HVAC Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:57:27 MICROPAS6 v6.01 File-24580B1 Wth-CTZ15S92 Program-HVAC SIZING -------User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC --------------------------------=------------------------------------ GENERAL INFORMATION Floor Area................. 4314 sf Volume.. ............ 46404 cf Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ INDIO Latitude ............. 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range... ..... ..... 30 F Interior Shading Used...... No Exterior Shading Used ...... .No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING -------------------------------- LOAD SUMMARY Heating Cooling Description -------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 27570 ----------- 9839 Glazing Conduction ............... 12628 10472 Glazing Solar .................... Infiltration n/a 21407 ..................... Internal Gain........... 27363 16216 ....... Ducts. n/a 3097 ................... Sensible Load 6756 6103 .................... Latent Load 74316 67134 ...................... n/a 13427 Minimum Total Load ----------- 74316 --- -------- 80560 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 8 HVAC --------------------------------------- _______ ________ __HVAC Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:57:27 -MICROPAS6v6-01File-24580B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----- - HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE '1.ZONE' Floor Area ...................... Volume 3827 sf ........................... 41534 cf Heating Cooling Description --------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 20611 ----------- 7486 Glazing Conduction ............... Glazing Solar 11490 9528 .................... Infiltration n/a 29528 .................... Internal Gain 24491 14514 .................... Ducts n/a 2982 ............................ 5659 5462 Sensible Load......... 62252 60084 Latent Load ...................... n/a 12017 Minimum Zone Load ----------- 62252 ----------- 72100 ZONE 12.ZONE' Floor Area ................... 487 sf f Volume............. ............ 4870 cf Heating Cooling Description ------------------------ (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 6959 ----------- 2353 Glazing Conduction ............... Glazing Solar.......... 1137 943 ........ Infiltration..................... n/a 1296 Internal -Gain 2872 1702 .................... Ducts n/a 116 ............................ 1097 641 Sensible Load .................... 12065 7050 Latent Load............. ....... n/a 1410 Minimum Zone Load 12065 . 8460 Madlin-'s enterprises Catherine M. Madlin, Certified Enemy Analyst . 760-322-5004 / 323-3644 (fax) ... v v vv Andalusia at Coral Mountain Series 75 Plan 5 - Lot 11 - Detached G.H. HVAC SIZING Page 1 HVAC Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13.58:45 Project Address........ LOT 11 - PLAN 5 DET.GH___ _____________ ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone........... 15 Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ----MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises. Run -LOT 11 REV PERMIT CALC - --------------------------------------------=---------------------- GENERAL INFORMATION ------------------- FloorArea ................. Volume.. .. ............ Front Orientation.......... Sizing Location............ Latitude... ....... Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range..... ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 4314 sf 46404 cf Front Facing 0 deg (N) INDIO 33.7 degrees 29 F 70 F 112 F 78 F 30 F No No No 0.20 HEATING AND COOLING LOAD SUMMARY -------------------------------- Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 27562 9832 Glazing Conduction ............... 12698 10530 Glazing Solar .................... Infiltration n/a 14126 ..................... Internal Gain 27363 16216 .................... Ducts. n/a 3097 ............................. Sensible Load 6762 5380 .................... Latent Load 74384 59180 ...................... n/a 11836 ----------- Minimum Total Load 74384 ----------- 71017 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 2 HVAC Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13.58.45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program-HVAC SIZING -User#_MP0207 User-Madlin's Enterprises Run -LOT ----- ------------------------------------------------------------- 11 REV PERMIT CALC HEATING AND COOLING LOAD ---------------------------------------- SUMMARY BY ZONE ZONE '1.ZONE' Floor Area ....................... Volume 3827 sf ......................... 41534 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) ----------- Opaque Conduction and Solar...... ----------- 20611 7486 Glazing Conduction ............... 11560 9587 Glazing Solar .................... Infiltration n/a 12305 ..................... Internal Gain .................... 24491 n/a 14514 2982 Ducts .............................. 5666 4687 Sensible Load........... ....... 62329 51560 Latent Load ...................... n/a 10312 Minimum Zone Load ----------- 62329 ----------- 61872 ZONE 12.ZONE' Floor Area ....................... Volume 487 sf ........................... 4870 cf. Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque_Conduction and Solar...... ----------- 6951 ----------- 2346 Glazing Conduction ............... 1137 943 Glazing Solar .................... Infiltration n/a 1821 .................. Internal Gain .................... 2872 n/a 1702 116 Ducts ............................ 1096 693 Sensible Load.... ...... ....... 12055 7621 Latent Load ...................... Minimum Zone Load n/a 1524 ---------------------- 12055 9145 HVAC SIZING Page 3 HVAC Project Title.......... ANDALUSIA.PLAN.S Date..11/09/04 13.58.45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program-HVAC SIZING User#_MP0207 User-Madlin's Enterprises Run -LOT 11 REV PERMIT CALC ------ ------------------------------------------------------------- GENERAL INFORMATION Floor Area ................. 4314 sf Volume.. ... ........... 46404 cf Front Orientation.......... Front Facing 90 deg (E) Sizing Location............ INDIO Latitude ................ 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range. ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 27562 ----------- 9832 Glazing Conduction ............... 12698 10530 Glazing Solar .................... Infiltration n/a 21471 ..................... 27363 16216 Internal Gain .................... n/a 3097 Ducts ............................ Sensible Load 6762 6115 .................... 74384 67260 Latent Load ...................... n/a 13452 ----------- Minimum'Total Load 74384 ----------- 80712 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 4 HVAC Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:58:45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program-HVAC SIZING User#_MP0207 User-Madlin's Enterprises Run -LOT 11 REV PERMIT CALC ----- ----------------------------------------------------------------- HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- i ZONE '1.ZONE' Floor Area ....................... 3827 sf Volume........................... 41534 cf Description --------------------------------- Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... InternalGain .................... Ducts............................ Sensible Load .................... Heating Cooling (Btuh) --------- (Btuh) 20611 ----------- 7486 11560 9587 n/a 20287 24491 14514 n/a 2982 5666 5486 62329 60341 Latent Load ...................... n/a 12068 ---------------------- Minimum Zone Load 62329 72409 ZONE '2.ZONE' Floor Area ....................... 487 sf Volume ........................... 4870 cf Description --------------------------------- Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... InternalGain .................... Ducts............................ Sensible Load .................... Heating Cooling (Btuh) ----------- (Btuh) 6951 ----------- 2346 1137 943 n/a 1184 2872 1702 n/a 116 1096 629 12055 6920 Latent Load ...................... n/a 1384 ---------------------- Minimum Zone Load . 12055 8304 HVAC SIZING Page 5 HVAC Project Title.......... ANDALUSIA.PLAN.S Date..11/09/04 13:58.45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -LOT 11 REV PERMIT CALC ------ -------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area ................. 4314 sf Volume. 46404 cf Front Orientation.......... Front Facing 180 deg (S) Sizing Location............ INDIO Latitude .................. 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. ..... ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Heating Cooling s Description. (Btuh) (Btuh) ------------------------------------------------------- Opaque Conduction and Solar...... 27562 9832 Glazing Conduction ............... 12698 .10530 Glazing Solar .................... n/a 11862 Infiltration ..................... 27363 16216 Internal Gain .................... n/a 3097 Ducts. .................... 6762 5154 Sensible Load .................... 74384 56690 Latent Load... n/a 11338 ---------------------- Minimum Total Load 74384 68028 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design 'temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. r, HVAC SIZING Page 6 HVAC Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:58:45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program-HVAC SIZING ------User#_MP0207 User-Madlin's Enterprises Run -LOT ------------------------------------------------------------- 11 REV PERMIT CALC HEATING AND COOLING LOAD ---------------------------------------- SUMMARY BY ZONE ZONE '1.ZONE' Floor Area ....................... Volume 3827 sf ........................... 41,534 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 20611 ----------- 7486 Glazing Conduction........... .. 11560 9587 Glazing Solar .................... Infiltration n/a 10170 ..................... Internal Gain .................... 24491 n/a 14514 2982 Ducts ............................ 5666 4474 Sensible Load...... 62329 49212 Latent Load ...................... n/a 9842 Minimum Zone Load ----------- 62329 ----------- 59054 ZONE 12.ZONE' Floor Area ....................... Volume 487 sf ........................... 4870 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 6951 ----------- 2346 Glazing Conduction ............... 1137 943 Glazing Solar .................... Infiltration n/a 1692 ..................... Internal Gain .................... 2872 n/a 1702 116 Ducts ............................ 1096 680 Sensible Load .................... 12055 7478 Latent Load ...................... n/a 1496 Minimum Zone Load ----------- 12055 ----------- 8974 HVAC SIZING Page 7 HVAC Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:58:45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin s Enterprises Run -LOT 11 REV PERMIT CALC ------ ---------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area... ....... 4314 sf Volume.. .......46404 cf Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ INDIO Latitude ............... 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. .. .. ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY -------------------------------- Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 27562 ----------- 9832 Glazing Conduction ............... 12698 10530 Glazing Solar .................... Infiltration n/a 21436 ..................... Internal Gain .................... 27363 n/a 16216 3097 Ducts. ................... 6762 6111 Sensible�Load .................... 74384 67221 Latent Load ...................... n/a 13444 - ----------- Minimum Total Load 74384 ----------- 80666 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also 'be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 8 HVAC Project Title.......... ANDALUSIA.PLAN.5 Date..11/09/04 13:58:45 MICROPAS6 v6.01 File-24581B1 Wth-CTZ15S92 Pro ram-HVAC SIZING -User#-MP0207 User-Madlin s Enterprises Run -LOT 11 REV PERMIT CALC ----- ---------------------------------------------------------------- HEATING AND ,COOLING LOAD ---------------------------------------- SUMMARY BY ZONE ZONE '1.ZONE' Floor Area.......... ... ..... Volume 3827 sf ........................... 41534 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 20611 ----------- 7486 Glazing Conduction ............... 11560 9587 Glazing Solar .................... Infiltration n/a 20140 ..................... Internal Gain 24491 14514 .................... Ducts n/a 2982 ............................ 5666 5471 Sensible Load .................... 62329 60179 Latent Load ...................... n/a 12036 Minimum Zone Load ----------- 62329 ----------- 72214 ZONE 12.ZONE' Floor Area ..................... Volume 487 sf ........................... 4870 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 6951 ----------- 2346 Glazing Conduction ............... Glazing Solar 1137 943 .................... Infiltration.. n/a 1296 ................. Internal Gain.. 2872 1702 .................. Ducts n/a 116 ............................. 1096 640 Sensible Load .................... 12055 7043 Latent Load ...................... n/a 1409 Minimum Zone Load ----------- 12055 ----------- 8451 Madlin-'s enterprises Catherine M. Madlin, Certified Energy Analyst • 760-322-5004 / 323-3644 (fax) ... v . v . s Andalusia at Coral Mountain Series 75 - flan 6 HVAC SIZING Page 1 HVAC Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10:17:04 Project Address........ PLAN 6 ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----- ----------------------------------------------------------------- GENERAL INFORMATION Floor Area................. 5089 sf Volume.. .. ....... .. Front Orientation.......... 54507 cf Front Facing 0 deg (N) Sizing Location............ INDIO Latitude ....... ........ Winter Outside Design 33.7 degrees 29 F ` Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range. .. .. ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No • Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING -------------------------------- LOAD SUMMARY Heating Cooling' Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ---------------------- 31000 11269 Glazing Conduction ............... 15441 12805 Y Glazing Solar .................... Infiltration n/a 21096 ..................... Internal Gain 32141 19048 .................... Ducts n/a 3097 -6731 ............................ Sensible Load .................... 7858 86440 74046 Latent Load ...................... n/a 14809 Minimum Total Load ---------------------- 86440 88855 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc.., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 2 HVAC Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10:17:04 MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE '1.ZONE' Floor Area ....................... 4526 sf Volume ........................... 48877 cf Heating Cooling Description ------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 25012 ----------- 9183 Glazing Conduction ............... 13899 11526 Glazing Solar .................... Infiltration n/a 18079 ..................... Internal Gain 28821 17080 .................... Ducts n/a 2982 ............................ 6773 5885 Sensible Load .................... 74505 64734 Latent Load ...................... n/a 12947 Minimum Zone Load ----------- 74505 ----------- 77681 ZONE 12.ZONE' Floor Area ....................... Volume 563 sf ........................... 5630 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 5988 ----------- 2087 Glazing Conduction ............... 1542 1279 Glazing Solar .................... Infiltration n/a 3016 ..................... Internal Gain 3320 1967 .................... Ducts n/a 116 ............................ 1085 847 Sensible Load... ............... 11936 9312 Latent Load ...................... n/a 1862 Minimum Zone Load ----------- 11936 ----------- 11174 HVAC SIZING Page 3 HVAC Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10:17:04 MICROPAS6v6-01File-24585B2 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----- - --------------------------------------------------------- GENERAL INFORMATION Floor Area ................ 5089 sf Volume. ......54507 cf Front Orientation.......... Front Facing 90 deg (E) Sizing Location............ INDIO Latitude......... 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range. ..... 30 F Interior Shading.Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description Btuh Btuh ---------------------------------------------- Opaque Conduction and Solar...... 31000 11269 Glazing Conduction.. .............. 15441 12805 Glazing Solar .................... n/a 21307 Infiltration.......... ......... 32141 19048 Internal Gain ......... .:.......... n/a 3097 Ducts. .7858 6753 SensibleLoad...... 86440 74279 Latent Load......... ............. n/a 14856 ---------------------- Minimum Total Load 86440 .89135 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. 9 HVAC SIZING Page 4 HVAC --------------------------------------- __________________________ Project Title.......... ANDALUSIA.PLAN.6-------Date__11/10/04 10:17:04 MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program-HVAC SIZING -User#_MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ------- ------------------------------------------------------------- HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE '1.ZONE' Floor Area.. .............4526 sf Volume ........................... 48877 cf Heating Cooling Description ----------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 25012 ----------- 9183 Glazing Conduction ............... Glazing Solar...... 13899 11526 .............. Infiltration n/a 20177 ..................... Internal Gain....... .................... 28821 17080 Ducts n/a 2982 ................ .......... 6773 6095 Sensible Load .................... 74505 67041 Latent Load......... ............. n/a 13408 Minimum Zone Load ----------- 74505 ----------- 80450 ZONE 12.ZONE' Floor Area ................... Volume........................... 563 sf 5630 cf Heating Cooling Description ----------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 5988 ----------- 2087 Glazing Conduction ............... Glazing Solar 1542 1279 .................... Infiltration...................... n/a 1131 Internal Gain .................... 3320 1967 Ducts...... n/a 116 .. ............. 1085 658 Sensible Load .................... 11936 7237 Latent Load ...................... n/a 1447 Minimum Zone Load ----------- 11936 ----------- 8685 HVAC SIZING Page 5 HVAC ------------------------------- Project Title.......... ANDALUSIA.PLAN.6---_------Date..11/10/04 10:17:04 MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program-HVAC SIZING -User#-MP0207 User-Madlin s Enterprises Run -REVISED PERMIT CALC ------- ------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area ................. 5089 sf Volume.. 54507 cf Front Orientation.......... Front Facing 180 deg (S) Sizing Location............ INDIO Latitude......... 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY -------------- Heating Cooling Description ---------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 31000 ----------- 11269 Glazing Conduction ............... 15441 12805 Glazing Solar .................... Infiltration n/a 19303 .................... Internal Gain .................... 32141 0 1948 Ducts............................ n41 048 97 Sensible Load 7858 6552 .................... Latent Load ...................... 86440 .72074 n/a 14415 Minimum Total Load ----------- 86440 ----------- 86488 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 6 HVAC Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10.17:04 ------MICROPAS6-v601 File-24585B2 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ---------------------.------------------------------------- HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE '1.ZONE' .............. s Floor Area.........4526 f Volume..... .. 48877 cf Heating Cooling Description (Btuh) (Btuh) ----------------------------------- ----------- Opaque Conduction and Solar...... 25012 9183 Glazing Conduction ............... 13899 11526 Glazing Solar .................... n/a 16286 Infiltration ..................... 28821 17080 Internal Gain .................... n/a 2982 Ducts ............................ 6773 5706 Sensible Load.................... 74505 62762 Latent Load ...................... n/a 12552 ---------------------- Minimum Zone Load 74505 75314 ZONE 12.ZONE' Floor Area ................... 563 sf Volume........................... 5630 cf Heating Cooling Description (Btuh) (Btuh) --------------------------------------------- Opaque Conduction and Solar...... 5988 2087 Glazing Conduction ............... 1542 1279 Glazing Solar .................... n/a 3016 Infiltration ..................... 3320 1967 Internal Gain .................... n/a 116 Ducts ............................ 1085 847 Sensible Load .................... 11936 9312 Latent Load ...................... n/a 1862 ---------------------- Minimum Zone Load 11936 11174 Heating Cooling Description (Btuh) (Btuh) --------------------------------------------- Opaque Conduction and Solar...... 5988 2087 Glazing Conduction ............... 1542 1279 Glazing Solar .................... n/a 3016 Infiltration ..................... 3320 1967 Internal Gain .................... n/a 116 Ducts ............................ 1085 847 Sensible Load .................... 11936 9312 Latent Load ...................... n/a 1862 ---------------------- Minimum Zone Load 11936 11174 HVAC SIZING Page 7 HVAC Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10.17.04 MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program-HVAC SIZING --------User#_MP0207 User-Madlin's Enterprises .Run -REVISED PERMIT CALC ----------------------------------------------------------- GENERAL INFORMATION Floor Area ................. 5089 sf Volume.. .... ............ 54507 cf Front Orientation.......... Front Facing Sizing Location............ INDIO Latitude ............. 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. .. . 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Heating Description --------------------------------- (Btuh) Opaque Conduction and Solar...... ----------- 31000 Glazing Conduction ............... 15441 Glazing Solar .................... Infiltration n/a ..................... Internal Gain 32141 .................... Ducts. n/a .................... Sensible Load .................... 7858 86440 Latent Load ...................... n/a Minimum Total Load 86440 270 deg (W) Cooling (Btuh) 11269 12805 22370 19048 3097 6859 75448 15090 90538 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 8 HVAC Project Title.......... ANDALUSIA.PLAN.6 Date..11/10/04 10.17.04 MICROPAS6 v6.01 File-24585B2 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -REVISED PERMIT CALC ----- -------------------------------------------------------------------- HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE '1.ZONE' Floor Area............ ......... 4526 sf Volume.. ....................... 48877 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 25012 ----------- 9183 Glazing Conduction ............... 13899 11526 Glazing Solar .................... Infiltration n/a 21559 ..................... Internal Gain.. 28821 17080 .................. Ducts n/a 2982 ............................ 6773 6233 Sensible Load .................... 74505 68562 Latent Load ...................... n/a 13712 Minimum Zone Load ----------- 74505 ----------- 82274 ZONE 12.ZONE' Floor Area ....................... Volume 563 sf ........................... 5630 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 5988 ----------- 2087 Glazing Conduction ............... 1542 1279 Glazing Solar .................... Infiltration n/a 811 ..................... Internal Gain .................... 3320 1967 Ducts n/a 116 ............................ 1085 626 Sensible Load .................... 11936 6886 Latent Load..... ............... n/a 1377 ---------------------- Minimum Zone Load 11936 8263 Madlin 's enterprises Catherine M. Ma.dlin, Certified EnerV Analyst v 760-322-5004 / 323-3644 (fax) . V . T T V T Andalusia at Coral Mountain Series 75 Plan 6 Lots I & 10 - Detached G.H. HVAC SIZING Page 1 HVAC Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:01:27 Project Address........ LOTS 1 & 10 PLAN 6 ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 Climate Zone........... 760-322-5004 15 Field C ec Date Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's ----- ----------------------------------------------------------------------- Enterprises Run -LOTS 1 & 10 REV. PERMIT GENERAL INFORMATION ------------------- Floor Area ................. 5099 sf Volume.. .. 54407 cf Front Orientation.......... Front Facing 0 deg (N) Sizing Location.........:.. INDIO Latitude... .... ....... 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. ... ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 i HEATING AND COOLING LOAD SUMMARY -------------------------------- Heating Description (Btuh) -------------------------------------------- Opaque Conduction and Solar...... 32233 Glazing Conduction ............... 15616 Glazing Solar ................... n/a Infiltration ..................... 32082 Internal Gain .................... n/a Ducts............................ 7993 Sensible Load .................... 87924 LatentLoad ...................... n/a Minimum Total Load 87924 Cooling (Btuh) 11653 12950 21166 19013 3097 6788 74666 14933 89600 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 2 HVAC Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:01:27 MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -LOTS ----- ---------------------------------------------------------------------- 1 & 10 REV. PERMIT HEATING AND COOLING LOAD ---------------------------------------- SUMMARY BY ZONE ZONE '1.ZONE' FloorArea ....................... Volume 4546 sf ........................... 48877 cf Heating Cooling l Description --------------------------------- (Btuh) (Btuh) ; Opaque Conduction and Solar...... ----------- 25632 ----------- 9374 Glazing Conduction ............... 14074 11671 Glazing Solar .................... Infiltration n/a 18150 .................. Internal Gain .................... 28821 n/a 17080 2982 Ducts ............................ 6853 5926 Sensible Load .................... 75379 65182 Latent Load ...................... n/a 13036 Minimum Zone Load ----------- 75379 ----------- 78219 ZONE 12.ZONE' t Floor Area.. ............. ....... Volume.... 553 sf ........ ........... 5530 cf Heating Cooling Description -------------------- (Btuh) (Btuh). Opaque Conduction and Solar...... ----------- 6601 ----------- 2279 Glazing Conduction ............... 1542 1279 Glazing Solar .................... Infiltration.......... n/a '3016 ......... Internal Gain .................... 3261 n/a 1932 116 Ducts ............................. 1140 862 Sensible Load .................... 12545 9484 Latent Load., ...................... n/a 1897 Minimum Zone Load ----------- 12545 ----------- 11381 HVAC SIZING Page 3 HVAC Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14.01.27 MICROPAS6v6�01--File-24586B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin s Enterprises Run -LOTS 1 & 10 REV. PERMIT ----- - -------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area ................. Volume.. 5099 sf .... ........... Front Orientation.......... 54407 cf Front Facing 90 deg (E) Sizing Location............ INDIO Latitude............ Winter Outside Design...... 33.7 degrees 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range. ..... ..... Interior Shading Used...... 30 F No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING -------------------------------- LOAD SUMMARY Heating Cooling Description ---------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ---------------------- 32233 11653 Glazing Conduction ............... Glazing Solar 15616 12950 .................... Infiltration n/a 21650 ..................... Internal Gain 32082 19013 .................... Ducts. n/a 3097 .................... Sensible Load. 7993 6836 .................... Latent Load 87924 75199 ...................... n/a 15040 Minimum Total Load ---------------------- 87924 90239 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 4 HVAC --------------------------------------- ------------------------------------ ________________________________ Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14.01.27 MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program-HVAC SIZING -User#-MP0207 User-Madlin s Enterprises Run -LOTS 1 & 10 REV. PERMIT ----- ----------------------------------------------------- HEATING AND COOLING LOAD ---------------------------------------- SUMMARY BY ZONE ZONE '1.ZONE' Floor Area ....................... Volume 4546 sf ........................... 48877 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 25632 ----------- 9374 Glazing Conduction ............... Glazing Solar 14074 11671 .................... Infiltration n/a 20519 .................. Internal Gain 28821 17080 .................... Ducts n/a 2982 ............................ 6853 6163 Sensible Load ... ................ 75379 67789 Latent Load ...................... n/a 13558 Minimum Zone Load ----------- 75379 ----------- 81347 ZONE 12.ZONE' Floor Area ..................... Volume........................... 553 sf 5530 cf Heating Cooling Description --------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 6601 ----------- 2279 Glazing Conduction............... Glazing Solar..... 1542 1279 ............. Infiltration n/a 1131 ..................... Internal Gain........ 3261 1932 .......... Ducts n/a 116 ............................ 1140 674 Sensible Load .................... 12545 7410 Latent Load ...................... n/a 1482 Minimum Zone Load ----------- 12545 ----------- 8892 HVAC SIZING Page 5 HVAC ------------------------------------------ Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14.01:27 MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -LOTS 1 & 10 REV. PERMIT ----- I -------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area ................. Volume.. 5099 sf .... ........... Front Orientation.......... 54407 cf Front Facing 180 deg (S) Sizing Location............ INDIO Latitude....... ..... Winter Outside Design 33.7 degrees 29 F ...... Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. ..... ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction........ 0.20 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ---------------------- 32233 11653 Glazing Conduction ............... Glazing Solar 15616 12950 .................... Infiltration n/a 19453 ..................... Internal Gain 32082 19013 .................... Ducts. n/a 3097 .................... + Sensible Load 7993 6617 .................... Latent Load 87924 72782 ...................... n/a 14556 Minimum Total Load ---------------------- 87924 87338 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. - It is the HVAC designer's responsibility to consider all factors when selecting.the HVAC equipment. i HVAC SIZING Page 6 HVAC Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14.01:27 MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -LOTS 1 & 10 REV. PERMIT --------------------------------------------------------------- HEATING AND COOLING LOAD ---------------------------------------- SUMMARY BY ZONE ZONE '1.ZONE' FloorArea ....................... Volume 4546 sf ........................... 48877 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 25632 ----------- 9374 Glazing Conduction ............... Glazing Solar 14074 11671 .................... Infiltration n/a 16436 .................... Internal Gain 28821 17080 .................... Ducts n/a 2982 ............................ 6853 5754 Sensible Load .................... 75379 63298 Latent Load ...................... n/a 12660 Minimum Zone Load ----------- 75379 ----------- 75957 ZONE 12.ZONE' Floor Area ...................... Volume 553 sf ........................... 5530 cf Heating Cooling Description ------------------------------ (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 6601 ----------- 2279 Glazing Conduction.. ............. Glazing Solar 1542 1279 .................... Infiltration n/a 3016 ..................... Internal Gain 3261 1932 .................... Ducts n/a 116 116 ............................ 1140 862 Sensible Load .................... 12545 9484 Latent Load ...................... n/a 1897 Minimum Zone Load ----------- 12545 ----------- 11381 HVAC SIZING Page 7 HVAC Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:01:27 MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -LOTS 1 & 10 REV. PERMIT ---------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area ................. 5099 sf Volume.. .... ........... 54407 cf Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ INDIO Latitude... .... ....... 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. .. ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY -------------------------------- Description --------------------------------- Opaque Conduction and Solar...... Glazing Conduction........... Glazing Solar .................... Infiltration ..................... Internal Gain .................... Ducts. ... ................... Sensible Load .................... Latent Load ...................... Heating (Btuh) 32233 15616 n/a 32082 n/a 7993 87924 n/a Cooling (Btuh) 11653 12950 22713 19013 3097 6943 76368 15274 ---------------------- Minimum Total Load 87924 91642 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 8 HVAC --------------------------------------- Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:01:27 MICROPAS6 v6.01 File-24586B1 Wth-CTZ15S92 Program-HVAC SIZING -User#-MP0207 User-Madlin's Enterprises Run -LOTS 1 & 10 REV. PERMIT ----- -------------------------------------------------------------- HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE '1.ZONE' Floor Area ..................... 4546 sf Volume ........................... 48877 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 25632 ----------- 9374 Glazing Conduction ............... 14074 11671 Glazing Solar .................... Infiltration n/a 21902 ..................... Internal Gain 28821 17080 .................... Ducts n/a 2982 .............. .......... . 6853 6301 Sensible Load.................... 75379 69309 Latent Load ...................... n/a 13862 ---------------------- Minimum Zone Load 75379 83171 ZONE 12.ZONE' Floor Area.. .................. 553 sf Volume........................... 5530 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 6601 ----------- 2279 Glazing Conduction ............... 1542 1279 Glazing Solar .................... n/a 811 Infiltration ..................... Internal Gain 3261 1932 .................... . Ducts n/a 116 ............................ 114.0 642 Sensible Load .................... 12545 7059 Latent Load ...................... n/a 1412 ---------------------- Minimum Zone Load 12545 8470 Madlin -s enterprzses Calherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) ..... v . Andalusia at Coral Mountain Series 75 Plan 6 - Lot 4 - No Guest House HVAC SIZING Page 1 HVAC Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:02:27 Project Address........ LOT 4 PLAN 6 w/o GH *******_____________________ ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 Climate Zone..... ..... 760-322-5004 15 _____________ Field C ec Date -------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercom Inc ---------------------------------------------------------------------Pl-------- -------------------------------------------------------------- ----------- -----MICROPAS6 v6.01 File-24587B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -LOT 4 REV PERMIT CALC F------------------------------------------------------------------------ GENERAL INFORMATION -------------- Floor Area ................. Volume. .... ........... Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design ...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range.. .. ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 4526 sf 48877 cf Front Facing 0 deg (N) INDIO 33.7 degrees 29 F 70 F 112 F 78 F 30 F No No No 0.20 HEATING AND COOLING LOAD SUMMARY -------------------------------- Heating 1 Description (Btuh) -------------------------------------------- 1 Opaque Conduction and Solar...... i Glazing Conduction ................ Glazing Solar .................... Infiltration .................. Internal Gain.. Ducts. ................... Sensible Load .................... LatentLoad...................... i Minimum Total Load 25618 14039 n/a 28821 n/a 6848 75325 n/a Cooling (Btuh) 9367 11642 18245 17080 3350 5968 65652 13130 75325 78783 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil `sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 2 HVAC Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:02:27 MICROPAS6 v6.01 File-24587B1 Wth-CTZ15S92 Program-HVAC SIZING ------User#-MP0207 User-Madlin's Enterprises Run -LOT 4 REV PERMIT CALC --------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area ................. 4526 sf Volume.. ........... 48877 cf Front Orientation.......... Front Facing 90 deg (E) Sizing Location............ INDIO Latitude ............. 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range........ ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load.Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY -------------------------------- Description --------------------------------- Opaque Conduction and Solar...... Glazing Conduction .............. Glazing Solar .................... Infiltration ..................... Internal Gain .................... Ducts. ................... Sensible Load............ ...... Latent Load ...................... Heating (Btuh) 25618 14039 n/a 28821 n/a 6848 75325 n/a Cooling (Btuh) 9367 11642 20374 17080 3350 6181 67995 13599 ---------------------- Minimum Total Load 75325 81594 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 3 HVAC Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:02:27 MICROPAS6 v6.01 File-24587B1 Wth-CTZ15S92 Program-HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run -LOT 4 REV PERMIT CALC ----- -------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area ................. 4526 sf Volume.. .. ............ 48877 cf Front Orientation.......... Front Facing 180 deg (S) Sizing Location............ INDIO Latitude.... 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F ! Summer Inside Design....... 78 F Summer Range. ... 30 F Interior Shading Used...... No Exterior Shading Used...... No ' Overhang Shading Used...... No Latent Load Fraction....... 0.20 t HEATING AND COOLING LOAD SUMMARY -------------------------------- Heating Cooling Description (Btuh) (Btuh) ----------- -------------------------------------------- Opaque Conduction and Solar...... 25618 9367 G Glazing Conduction ............... 14039 11642 Glazing Solar .................... n/a 16483 Infiltration ..................... 28821 17080 Internal Gain.. n/a 3350 . r. Ducts 6848 5792 Sensible Load .................... 75325 63715 Latent Load ............... n/a 12743 - - - - - - - - - - - - - - - - - - - - Minimum Total Load 75325 76458 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 4 HVAC ---------------------- ------------------------------------- ---------------------------------------- Project Title.......... ANDALUSIA.PLAN.6 Date..11/09/04 14:02:27 MICROPAS6 v6.01 File-24587B1 Wth-CTZ15S92 Program-HVAC SIZING ------User#-MP0207 User-Madlin's Enterprises Run -LOT 4 REV PERMIT CALC -------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area. ........ ........ 4526 sf Volume.. .... ... ....... Front Orientation.......... 48877 Front cf Facing Sizing Location............ INDIO Latitude............ Winter Outside Design...... 33.7 29 F degrees Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range...... ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY 270 deg (W) Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 25618 ----------- 9367 Glazing Conduction ............... 14039 11642 Glazing Solar .................... Infiltration n/a 21724 ..................... Internal Gain 28821 17080 .................... Ducts n/a 3350 ............................ Sensible Load......... 6848 6316 ......... Latent Load 75325 69480 ...................... n/a 13896 ----------- Minimum Total Load 75325 ----------- 83376 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. �l a d1in s 9 en terpmes Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) .... . e V G 0 0 a Addendums and Notes v 0 a Madlin s en terprises Catherine M. Madlin, Certified Energy Analyst • 760-322-5004 / 323-3644 (fax) ....... Title 24 Building Energy Efficiency Standards Residential Manual Excerpt RADIANT BARRIERS Introduction A radiant barri heat. Aluminui Installation of although they of radiant material. season, The Commission has approved an energy credit for radiant barriers meeting specific eligibility and installation -criteria. The radiant barrier energy credit is an adjustment to the ceiling U-value when the ceiling is adjacent to an attic with a radiant barrier. The credit is automatically applied by modeling a. radiant barrier in an approved computer program with this optional capability. Construction Below are the parameters for receiving credit for a radiant barrier, including criteria for the,' installation, ventilation and material, all of which contribute to the performance of the radiant barrier. Installation Installation must be in conformance with ASTM C-1158-97 (Standard Practice for Use and Installation of Radiant Barrier Systems (RBS) in Building Construction.), ASTM C-727- 90(1996)e1 (Standard Practice for Installation and Use of Reflective Insulation in Building ConstrluctiorT.), ASTM CT313-975 (Standard Specification for Sheet radiant Barriers for Building `Construction Appli g ations), and ASTM C-1224-99 (Standard Specification for Reflective Insuja$i�yfor Buiidinq Applications and the radiant barrier must be securely i stalled in a perm Radiarht I memoos, t "i d t a is oo /� rs (op c o ds ny - ov rig 1. Draped over the truss/rafter ( the top chord) before the upper roof deck is installed. 2. Spanning between the truss/rafters (top chords) and secured (stapled) to each side. 3. Secured (stapled) to the bottom surface of the truss/rafter (top chord). A minimum air space must be maintained between the top surface of the radiant barrier and roof decking of not less than 1.5 inches at the center of the truss/rafter span. • P.O. Box 1443 v Palm Springs, Ca 92263-1443 • E-mail. Cmadlin@aol.com • Madlin's Enterprises — Addendums & Notes 4. Attached [laminated] directly to the underside of the roof decking. The radiant barrier must be laminated and perforated by the manufacturer to allow moisture/vapor transfer through the roof deck. The radiant barrier must be installed to cover all gable end walls and other vertical surfaces in the attic. , Ventilation 'The attic must be eE ntila ed to: / AJJ U 1. Conform to m ufa�tOrer ssi t'str ictiorTs- 2. Provide a rrJi im �n freg entilatior� area o n t less tha ne square foot f ent area for each 150 sp are eetlaf atticfloor'arEa� U 3. Provide no less than 30 percent upper vents. (Ridge vents or gable end vents are recommended to achieve the best performance. The material should be cut to allow for full air flow to the venting.) The radiant barrier (except for radiant barriers laminated directly to the roq.deck) must be installed to: 1. Have a minimum gap of 3.5 inches between the bottom of the radiant barrier and the top of the ceiling insulation to allow ventilation air to flow between the roof decking and the top - surface of the radiant barrier. 2. Have a minimum of six (6) inches (measured horizontally) left at the roof peak to allow hot air to escape from the air space between the roof decking and the top surface of the radiant barrier. When installed in enclosed rafter spaces where ceilings are applied directly to the underside of roof rafiterrs,—�a minimum air space of 1 inch must be provided between the radiant barrier and the top f the ceiling insulaation, and ventilation must be provided'for each rafter space. Vents must qe proved at b h the 'Upp er-andjov ncisof-t a E nclosed-rafter-space- Emissivi �J The emissivity of the radiant barrier must bp less than or equal to 0.05as tested in accordance with ASTM C-1371-98 or AST JE408-7(1996)e1. • The product must meet all requirements for California certified insulation material [radiant barriers] of the Department of Consumer Affairs, Bureau of Home Furnishings and Thermal Insulation. y .� Madlin's Enterprises Addendums & Notes v . Note: Aluminum will deteriorate or corrode in the presence of alkaline materials. Unless the aluminum foil is protected by waterproofed paper or plastic coating, keep it from coming into direct contact with anything alkaline, such as masonry surfaces. Inspection If a radiant barrier was used for compliance credit, check the installation guidelines provided above for the builder. Especially'critical are the ventilation and air space requirements that enable the radiant barrier to perform as expected. , Iv-CCEC Title 24 Fesiden gal Pesig anuI I 001 ol at v Figure 3-2: Methods ' or n§tallat'o for R iant Barr,%r's } ' } j _.r . r .:fir s,_, • � ' r t �J. +[ n f t I• 'V - � _ ' • is `y JL Madlin's enterprises Catherine M. Madlin, Certified Energy Analyst . 760-322-5004 / 323-3644 (fax) ....... Title 24 Building Energy Efficiency Standards Residential Manual Excerpt THERMOSTATIC EXPANSION VALVES Thermostatic expansion valves (TXVs) or an equivalent alternative approved by the Commission are required for split system central air conditioners in some compliance methods and calculations. I,,f TXVs, are required for compliance flgld verification (usual confirmation) by a certified HERS rater i's;lr)equired. j, i 'i %( 1, V /...-....y 4 /r•__-'\,l i ,.-.... I-_"�..wti\ f HERS Raters Approved HERS-faters conduct -the -fie ldwerification diaghostic testing and inspections, and provide Certificate of Field Verification and Diagnostic Testing (CF-4R) forms or notification that corrective actions are needed. HERS raters must be independent of both the builder and sub- contractor who installed the duct systems being field verified, and can have no financial interest in making corrections to the systems. As special inspectors HERS raters can not be employed by subcontractors or parties, other than the builder, whose work they are evaluating. Building Departments Building departments consider approved HERS raters to be special inspectors. HERS raters must demonstrate competence, to the satisfaction of the building official, for the visual inspections and diagnostic testing. The building department, at its discretion, may require field verification testing and inspection to be conducted in conjunction with the building department's required inspections, and/or observe installer diagnostic testing and HERS rater verification in conjunction with the building department's required inspections to corroborate the results documented in installer certifications, and in the Certificate of Field Verification and Diagnostic Testing (CF-4R). I 3 I i r it ��'r, W 1' j i r ''f `r✓ / \(\\ LJ 4 i • P.O. Box 1443 • Palm Springs, Ca 92263-1443 v E-mail: Cmadlin@aol.com v Madlin s 9 en terprises Catherine M. Madlin, Certified Energy Analyst . 760-322-5004 / 323-3644 (fax) ....' ... o e � 9 p � ' O Manufacturer's Specifications Resistance Factor ( ) of CO2,rnpon Esuifding Materials, ,sir Spaces and Films L 2uiL4' inq Bnaed rm-value Gypsum Board 1/2" 0.45 5/8" 0.56 Plywood 1/4" 0.31 „ 3/8" 0.47 1/2" 0.62 3/4" 0.94 Hardboard, Underlayment 1/4" 0.31 1" 1.24 ► u-iiding Paper Permeable Felt, 151b. 0.06 Plastic Film Neg Concrete blocks, three oval cores Cinder aggregate 4"thick 1.11 12" thick 1.89 8" thick 1.72 Sand and Gravel Aggregate 8" thick 1.11 Lightweight Aggregate 8" thick 2.00 4° thick 1.50 Gypsum Mortar or Plaster 1/4" 0.05. 1/2" 0.10 1" 0.20 Gypsum Plaster (Perlite) 1" 0.64 Gypsum Plaster (Vermiculite) 1° 0.59 Brick, per inch 0.20 Fake brick, per inch 0.11 Stucco, per inch 0.20 Roofing Viateariais Asbestos Cement Shingles 0.21 Asphalt Roll Roofing 0.15 Asphalt Shingles 0.44 Built Up Roofing 3/8' 0.33 Wood Shingles 0.94 .Siding tNlaterials - Asbestos Cement, 1/4" thick lapped 0.21 Asphalt 0.15 Wood Shingle, 16"x7.5' Exposure 0.87 Double with 12" Exposure 1.19 Wood Drop Siding, 1 °x8" 0.77 Wood Bevel Siding, .5"x8" (lapped) 0.81 Wood Bevel Siding, .3/4"x10° (lapped) 1.05 Wood Plywood, .3/8" (lapped) 0.59 Structural Glass 0.10 Insulation Materia.s �i-valeae Insulation Board - FALCON FOAM, @ Type 1/75-F 3.90 FALCON FOAM, @ Type VIII/75•F 4. 0 FALCON FOAM, @ Type I1/75"F 4.40 FALCON FOAM, @ Type IX/75"F 4.40 Extruded Polystyrene @ 75"F 5.00 Polyurethane/Polyisocyanurate Aged @ 75•F 5.60 Insulation batts:blankets Mineral Wool Per Inch/75•F 3.66 Insulation Loose Fill FALCON FOAM, 3.40 Cellulosic/Inch 3.1-3.7 Perlite, Expanded/Inch 2.2-2.9 Vermiculite, exfoliated/inch 2.1-2.3 Air S.p2cec (214'j . Heat Flow Up Non -reflective 0.75 (Summer) 0.87 (Winter) Reflective, one surface 2.22 (Summer) 2.21 (Winter) Heat Flow Down Non -reflective 0.85 (Summer) 1.02 (Winter) Reflective, one surface 3.29 (Summer) 3.59 (Winter) Heat Flow Horizontal Non -reflective 0.84 (Summer) 1.01 (Winter) Reflective, one surface 3.24 (Summer) 3.46 (Winter) Surface Air t~iir-ss, Inside (Still Air) . Heat Flow Up (through a horizontal surface) Non -reflective 0.61 Reflective 1.32 Heat Flow Down (through a horizontal surface) Non -reflective 0.92 Reflective 4.55 Heat Flow Horizontal (through a vertical surface) Non -reflective 0.68 F;Aaving Air Surfaces Any Position or Direction 15 MPH Wind (Winter) 0.17 7.5 MPH Wind (Summer) 0.25 � c. L ` Falcon Foamy Y Andersen® Center of Glass Performance Data Dual -Pane Glass Visible { + ° Inside Surface (Air filled Li t I SC' SHGC' RHG` Fading I Tuvs Tdw° I j %HR Glass I_ U-Factor';@center` j Temp9 Casement/Awning, Tilt•Wash, _ -- Woodwright, Nan•oline° Transom -- - 83°h r 0.92 j 0.79 J 191 62% I ° 64/0 0.50 I 41% ° 45 F Fixed (Picture Windows)_ 82% 0.90 j 0.77 - 187 I 57% I 60% j 0 49 j 41% 46°F Circle Top'" ---- p-- 83% --- 0.92 1 0.79 191 I --.o 62% I 65% 0.49 ; 41% °_ I 45 F Perma•Shield° - Narroline° Gliding Patio Door Fleldhame° Arch To S 82% 0.87 0.75� 181 i 54% I r '---7 58% I 0.49 ' ----- j 42% j 46°F n Pr P ngline'" L 80°6 0.82 0.71 172 1 47% 1 53% ! 0.48 42% -_. 46°F High -Performance" Low-E Glass (Dual -pane, Low-E, argon blend filled) Casement, Awning, Tik-Wash, Woodwright;"Transom Picture, Awning Double -Hung Picture trsible Light' 73% SC' SHGC= RHG` I0._50_ 0.43I 104 _ 0.49 0.43 I 102 j 0.50 ( 0.43 1 104 -' i'-'-' -- 0.50 j 0.43 I 104 I - 0.49 0.42 101 j 0.49 j 0 4242 101 j 0.47 0.41 98 0.49 0.43 j 102 j - 0.49 0.42 1 SO1 Fading Tuve Tdwa 17/I 3-4_%_. T ! 16% I 33% ; 17°k 34% I 17% 1 34% 15°"b 32% _ 15% 32°� 14°� 31% 16% 1 3_3% , _ 2%_25% t U-Factor'I@center` I %uHR Inside Surface Glass I Temp' I0.28 0.28 0.28_ j 0.28 I _ 0.27 I 0.28% I60% -i j 60% 60% ? _ 60% I 60°h 60% j 55°FCasement 73. I_56°F 56°F Gliding Windows (400 Series) Circle Top, Elli�ltical_ Top, Circle, Oval 73% 73% 1 72% I Perma-Shield° Patio Door, Narroline° Gliding Patio Door 56°F 56°F Frenchwood° Hinged, Outsw_ing, Gliding FlexiframemArch Windows, Sprirlgline'" 72°,6 71% 1 56°F 0.27 _ 61% 60% _ 60% 1 56°F 56°F Roof Window VSlrylights (tempered) Laminated (all products) 7373%I 0 28 0.28 I 71°� 56° F High -Performance Sun- I Inside Low-E Glass (Dual -pane, tinted argon blend filled) Visible Light' SC= SHGC' RHG` Fading Tuva Tdwe %HR JU-Factor'ocentera Surface Glass Casement, Awning, Tik-Wash, g, rift -Wash, 1 � j Temps Woodwright; Transom _ _ Picture Units: CA NL DHP 40% i 40% 0.36 0.35 _ 0.31 I I 76 1(3%_ i 24% 0.31 1 58% 1 54°F_ Gliding Windows -_ _- _.-� 40% 0.36 0.30 j 0.31 74 i 75 15% j ---' 16% 23% 24°� 1 0.30 1 - - 0.30 57% 57% ' S4°F _.�__ j 54°F Circle Top'; Oil 0! al Top, Circle, Oval _40% I 0.36 _ 0.31 75 ! 16°k j 24% 0.30 57% 54°F Perma-Shield° Patio Door Frenchwood° Hinged, Gliding ----- g r 39% j 39°h 0.34 0.35_ 0.30 0.30 - 73 1 - 14% 22% - - 1 0.30 1 58% 54°F _g Flexiframe° Arch Windows, Springline_" _ 38°� 0.33 _ 0.29 73 I 71 I 14°G 13� 22_% 21% j 0.30 j j 0.30 j 58% -- 54°F j _Roof Windows/Skylights (tempered) - 39% 0.34 0.30 I 73 1 14% I 22% I 58% 55°F I -- Laminated (all products) - - - - 39% 1 0.35 0.30_ �- 73 1 2% 16% 0.30 - - j 0.30 j 58% - _o 54°F - , -- 58 fi I 55 F This data is accurate as of August 12, 2003. Due to ongoing product changes, updated test results, or new industry standards, this data may change over rime. Canadian Product Performance Ratings Tested to: CAN/CSA A440-M90 The mullion was tested and the deflection was within the maximum allowable of L/175 at Dositive and nPoativa Innrie of )rnn o° Units Tested CW16 P6050 _ _ AP421V A3535 TW3862 NL3862 DHP5662 _ G65_ _ 9ir/00 3048 ET8- - - Air Tightness Waterstance Tightnesslow-out dload Land I R A-3 Fixed _ B-7 j 8-7 B-4 B-3 j B-3.LC-3 B 3 B-3 B-3 B-7 B-7 I _ C-4 C-4 No -Not Not Not - A-3 G2 C-i�l - A-2 A-3 _ Fixed C-2 C-3 A-3 C 3 Fixed C-5 Fixed C-5 Not esistance to forced entry tApplicable Units Tested ?ass FX-12050 AF-608 Pass SP-802 Pass FWH6080AP Pass 9080SASR Pass FW06080AP Applicable 3180 Pass FWG8080 Applicable 160611 Applicable PSG8080 238 --- 'High-Performance'(HP Low-E) and 'High -Performance Sun' (HP Sun) are Andersen trademarks for "Low-E" glass. Based on NFRC testing/simulation conditions using Windows 4.1 and NFRC validated spectral data. o°F outside temperature, 70°F inside temper. ature and a 15 mph wind. 1 Visible Transmittance (VT) measures how much light comes through the glass. The higher the value, from 0 to 1, the more daylight the glass lets in. Visible Transmittance is measured over the 380 to 760 nanometer portion of the solar spectrum. 2 Shading Coefficient defines the amount of heat gain through the glass compared to a single lite of clear 1/8' (3 MM) glass. 3 Solar Heat Gain Coefficient (SHGC) defines the fraction of solar radiation admitted through the glass both directly transmitted and absorbed and subsequently released inward. The lower the value, the less heat is transmitted through the glass. 4 Relative Heat Gain Is calculated under a different set of assumptions than thermal Performance. 5 Transmission Ultra -Violet Energy (TUV). The transmission of short wave energy in the 300- 380 nanometer portion of the solar spectrum. The energy can cause fabric fading. 6 Transmission Damage Function (TDW). The transmission o1 short wave energy in the 300- 600 nanometer portion of the solar spectrum. The value includes both the UV and visible light energy that can cause fabric fading. This rating has also been referred to as the Krochmann Damage Function. This rating better predicts fading potential than UV transmission alone. The lower the Damage Function rating, the less transmission of short wave energy through the glass that can Potentially cause fabric fading. Fabric type Is also a key component of fading potential. 7 U-Factor is a measure of the heat loss through the total unit In BTU/hr deg.F sq. ft. 8 Percent relative humidity before condensation occurs at the center of glass, taken using center of glass temperature. 9 Inside glass surface temperatures are taken at the center of glass. Air Tightness Water Tightness Wmilload Resistance and blow-out Resistant to forced entry Fixed Fixed _-Fixed --- AA-3 I 8_-7 B-7 B-7 B-2 C-5 _N_otApplical Not ��licaI NotApplicat Pass C-5 _ C-5 C-3 - _. A_3 - A-3 _ A-3 _ A --- 3 A 3 B-2 B-4 B-4 E73 B-2 - C-3 _ C-3 C-3 _7�__ Pass_ Not Applicat Not Applicak Pass PassA-3 B-2 Pass e Performance Data Andersen' NFRC Certified Total Unit Performance Andersen windows and patio doors meet or exceed the following standards: WDMA,-I.S: 2, W.D.M.A A.S. (WDMA license No. 129). Hallmark certified. Independent testing laboratories have performed all required tests on selected sizes. Compliance with these standards is confirmed by ongoing testing in Andersen Laboratories. These products are covered by one or more o1 the following patents: 4,999,950; 5,595,409; 5,775,749; 6,055,786; 5,544.450; 5,566,507; 5.582,445; 5.097,629; 5,740,632; 5,199,234; D312,565; D397,604; and D417,831. Other patents pending. Without Grilles 400 Series Windows HP HP Sun HP HP Sun Andersen' Product Type Low-E I Low-E Low-E ! Low-E Casement U-Factor' 0.33 0.35 0.34 i 0.36 24" x 48" size SHGC' 0.33 0.24 0.30 0.22 VP 0.53 0.29 0.48 0.26 Awning U-Factor' 0.33 0.35 0.34 0.36 48" x 24" size SHGC' 0.32 ! _0.24_ 0.30 0.22 VP 0.52 0.28 0.47 1 0.26 Casement/Awning U-Factor' 0.30 1 0.32_ j 0.34 Picture Window SHGC' 0.36 _0.32 0.26 0.33 0.24 48" x 48" size VP 0.59 0.32 0.53 I 0.29 Woodwright'" U-Factor' 0.33 I 0.35 0.34 0.36 Double -Hung SHGC' 0.32 0.24 _0.29 j 0.22 36" x 60" size VP 0.51 0.28 0.46 I 0.25 Woodwright" U-Factor' _0.30 1 0.32 0.3_2 i 0.34 Picture Window SHGC' 0.33 I 0.24 0.31 1 0.22 48" x 48" size VP 0.54 0.29 0.48 I 0.26 Woodwright" U-Factor' 0.30 1 0.32 0.32 i 0.34 Transom SHGC' 0.35 0.25 0.32 i 0.23 48" x 48" size VP 0.57 0.31 0.51 i 0.28 Tilt -Wash U-Factor' 0.34 _0.36 0.35 1 0.35_ Double -Hung SHGC' 0.32 i 0.24 0.29 0.22 36" x 60" size VP 0.51 i 0.28 0.45 0.25 Tilt -Wash U-Factor' 0.33 i 0.3_5__ 0.35 0.37 Double -Hung Picture SHGC' 0.35 i 0.25 0.32 j 0.24 48" x 48" size VP 0.56 ; 0.30 0.50 0.27 Tilt -Wash U-Factor' 0.33 0.35 0.34 I 0.36 Double -Hung Transom SHGC' 0.35 1 0.25 0.32 0.23_ 48" x 48" size VP 0.56 0.31 0.50 i 0.27 Gliding Window U-Factor' 0.36 1 0.38 0.38 i 0.39 60" x 36" size SHGC' 0.30 0.23 0.28 _0.21 VP 0.46 I 0.25 0.41 ! 0.22 Elliptical Window U-Factor' 0.30 0.32 0.32 0.34 48" x 48" size SHGC' 0.36 I 0.26 _ 0.33 J 0.24 VP 0.59 ; 0.32 0.53 1 0.29 Circle Top" U-Factor' 0.30 ! _0.32_ 0.32 ; 0.34_ Casement SHGC' 0.36 i 0.26 0.33 I 0.24 0.53 i 0.29 48" x 48" size VP 0.59 0.32 Circle/Oval U-Factor' _0.30 0.32 0.32 i 0.34 48" x 48" size SHGC' 0.36 0.26 _ 0.33 0.24 VP 0.59 ! 0.32 0.53 ! 0.29 Arch Windows U-Factor' 0.31 0.33 0.32 ! 0.3_4 48" x 48" size SHGC' 0.36 0.26 I 0.24 VP 0.59 1 0.32 _0.33 0.53 0.29 Flexiframe° U-Factor' 0.30 0.32 0.32 0.34 48" x 48" size SHGC' 0.36 __0.26 L 0.33 - 0.24 VP 0.59 0.32 0.53 1 0.29 Springline' Window U-Factor' 0.34 0.36 0.36 0.38 48" x 48" size SHGC' 0.35 0.26 0.32 0.24 VP 0.55 0.30 0.50 0.27 Tempered Skylight U-Factor' 0.44 0.46 0.44 0.46 48" x 48" size SHGC' 6.42 _ 0.31 _ 0.42 0.31 VP 0.67 0.37 0.65 ! 0.36 Venting U-Factor' 0.42 0.44 0.42 0.44 Roof Window SHGC' 0.40 0.29 0.39 0.29 48" x 48" size _ VP 0.62 0.34 0.60 0.33_ V Stationary _ U-factor' 0.42 ? 0.44 0.42 0.44 Roof Window SHGC' 0.40 0.30 1 0.39 0.29 48" x 48" size VP 0.64 0.35 1 0.60 I 0.33 400 Series Doors Andersen' Product Type Without Grilles HP i HP Sun Low-E I Low-E HP Low-E 1 HP Sun Low-E Frenchwood' Gliding Patio Door 72" x 82" size U-Factor' SHGC' VP 0.33 j 0.29 j 0.44 0.35 0.21 0.24 0.35 - 0.26 0.36 0.20 0.21 0.39 Frenchwood' Hinged Patio Door 38" x 82" size U-Factor' SHGC' VP 0.33 0.27 i 0.41 0.34 0.20 0.22 --0.367 0.34 0.36 0.19 0.20 0.25 Frenchwood' Outswing Patio Door 38" x 82" size U-Factor' SHGC' VP 0,34 0.27 i 0.41 1 0.36 0.20 0.22 0.36 I 0.25 0.36 ! 0.37 0_19 0.20 Frenchwood' Patio Door Sidelight 16" x 82" size U-Factor' SHGC' VP 0.35 0.20 1 0.27 0.36 0.15 0.15 0.35 0.36 _ 0.15 0.14 0.19 i 0.26 Frenchwood° Patio Door Transom 38" x 14' size U-Factor' SHGC' VP 0.34 i 0.16 _ 0.20 0.35 0.13 0.11 0.34 I 0.35 0.12 0.10 0.15 I -.� 0 1? 200 Series Windows & Doors Andersen' Product Type Without Grilles_ -Clear Dual -Pane: Low-E Clear Dual -Pane Low-E Casement 24" x 48" size U-Factor' SHGC' VP 0.48 _ 0.57 0.59 ! - j a _ 1 - 0.49 0.52 - 0.54 Awning 48" x 24" size U-Factor' SHGC' VP 0.48 0.56 0.58 1 = i -_ - 0.49 1 = = ! - 0.52 0.53 Tilt -Wash Double -Hung 36" x 60" size U-Factor SHGC' VP 0.49 0.56 0.58 0.34 ___0.33 1 0.51 0.50 0.35 0.51 0.30 i 0.46 0.52 Narroline° Double -Hung 36" x 60" size U-Factor' SHGC' VP 0.50 0.58 0.60 0.35 i 0.33 1 0.53- 0.50 1 0.36 0.52 ! 0.31 --0-5-37 _ 0.47 Narroline° Transom 48" x 48" size U-Factor' SHGC' VP 0.47 0.59 0.62 0.31 0.34� ! 0,55 0.48 1 0.33 0.54 1 0.31 0.56 1 0.49 Gliding Window 60" x 36" size U-Factor' SHGC' VP 0.50 0.57 0.58 1 0.35 1 0.33 1 0.52 0.50 1 0.35 0.51 1 0.30 0.52 1 0.46 Fixed, Transom, Circle Top" 48" x 48" size U-Factor' SHGC' VP 0.47 0.60 0.62 0.31 ! 0.34 - 1 0.55 0.48 1 0.33 0.54 0.32 0.56 1 0.49 Narroline° Gliding Patio Door 72" x 82" size U-Factor' SHGC' VP 0.49 6.60 0.62 ; 0.32 0.35 --0.55 0.50_ 0.35 0.54 " 0.32 0.56;­0.49 Perna -Shield' Gliding Patio Door 72" x 82" size U-Factor' SHGC' VP 0.47 0.60 0.62 1 0.3_1 _ 0.34 ; 0.56 0.48'11 0.33 0-5 7 0.32 0.56 0.50 Grilles-Flnelight or Full Divided light. 'High -Performance" (HP Low-E) and -High-Performance Sun" (HP Sun) are Andersen trademarks lot -t.ow-E' glass. 1 U-Factor defines the amount of heat loss through the total unit in BTU/hr sq. h•.°F. The lower the value, the less heat is lost through the entire product. 2 Solar Heat Gain Coefficient (SHGC) defines the fraction of solar rradiotion admitted through tMe glass both directly transmitted and absorbed and subsequently released inward. The lower the value, the less heat is transmitted through the product 3 Visible Transmittance (Vr) measures how much light comes through a product 1@ass and frame). The higher the value, from 0 to 1, the more daylight the product lets In over the preduci s total unit area. Visible Transmittance is measured over the 380 to 760 nanometer portion of the solar spectrum. This data is accurate as of August 12, 2GO3. Due to ongoing product changes, updated test results, or new industry standards, this data may change over time. . 239 Andersen® 400 Series Air Infiltration, Testing and Light Transmittance Sound AAMA/WDMA Certified I Trans. i Andersen' Product Performance Rating 101/ I.S. 2/NAFS-02 standard Air Infiltration crm/W I class fin, nr m' r 400 Series CasementWindowt - DP 40 C-C 40 36 x 72 1 0.03 (.54) . 25 22 1.400 Senl s Awning WindooWt DP 35 AP-C 35 65 x 28 j 0.04 (.73) j 26 I 22 400 Senes Casement ; 1 I kand Awning Ptcture Windowst� f, • i DP 60 F-C 60 72 x 60 <.01 (.18) I 30 I 25 4MSeries Woodwng!T Double Hung>T� ,, "-i, DP 30 sr 400 Series Woodwnghf 0.14 (2.52) j j 27 23 H-LC 30 46 x 77 Dbuble'Hung Picture Window DP 65 F-C 65 67 x 77 <.01 l I 1 400 Senes WoodwnghCt I (.18) 28 _ 23 , Double Hung»Transom Wlridow T DP 65 400 SenesTill:W8hxDouble--Hgngt (vritlt.SlandaNsillSmp-)sdtv�q': ' DP 30 I TR-LC 65 75 x 27 I <.01 I 0.10 (.18) (1.80) I _ 28 27 i 22 I I 23 H-R 30 46 x 72 400 Serves At Wash Double Hung' 52 (1321mmj Height and Under t' DP 50 H-R 50 38 x 65 0.24 (4.39) 27 j 23 400 SenesTtt Wash Double Nun g ` PicUlre�Windowt DP 50 F-R 50 67 x 77 I <.OS (.18) 26 - 400 Sends Tilt Wash Double Hun g,. Transom Windowt DP 30 ** 0.05 (.91) 27 I 23 HS-C 30 72 x 60 400 Serves Gliding Window DP 30 0.02 (.36) 25 21 400 Serves Roof Wind nary i DP 40 DP * * I _ _ . 0.01 (.18) 30 24 i400 Serves Roof Windfifiow (VeWg) ., DP 25 * * I 0.01 0.02 (.18) (.36) 34 30 28 I 24 40,0 SenesSkylightt»$i DP 65 SKG-C 65 56 x 56 400 Se�C�ircle op and ' �E11ipUplVJindowst DP 65 ** I <.01 I <,Ol <.01- <.01 (.18) (.18) 32 - 25 - - 400 Serves Circle and Oval Wlndowt) DP 65 ** -0ek eneseAich Wlndow,t �} :; DP 65 DP 65 ** 4QO Serves Flexrh'ame;Wmdowt'.: 400�Se6es Sodnglme. Wmdowt-, DP 65 F-HC 65 96 x 72 (-<.01 (.18) - - S.j;. 406 Series Frenctiwoo& Gtidi g Pabo Doorsti;''-{ 16080 DP 35 SGD-LC 35 189�x 96 0.05 0.05 (.91) (.91) 31 i I 31 26 26 160611 SRD DP 25 REINFORCED SGD-LC 25 189 x 82 DP 40 SGD-LC 40 189 x 82 0.05 (.91) 31 26 SGD-LC 30 189 x 80 16068 _ DP 30 0.06 (1.10) 31 I 26 SGD-LC 50 96 x 96 10.03 _8080, 6080 DP 50 (.54) 31 26 SGD-LC 60 96 x 82 10.08 60611, 8068, 80611, 6080 DP 60 (1.46) 31 26 6080 AP/PA DP 40 HGD-R 40 71 x 96 0.02 (.36) 32 26 9080 SASR _DP 40 HGD-R 40�107 x 966 _0.01 (.18) 32 26 _6080 SA 3180 S DP 40 1 DP 60 HGD-R 40 71 x 96 j HGD-R 60 36 x 96 0.01 0.02 (.18) (.36)_ P32 26 26 90611 SASR DP 50 HGD-R 50 107 x 82 0.01 (.18) 32 I 26 HGD-R 40 71 x 82 I 60611 AP/PA DP 40 0.02 (.36) 2 I 26 HGD-R 50 71 x 82 60611 SA DP 50 0.01 (.18) 32 26 HGD-R 60 36 x 82 31611 A DP 60 0.01 CIE 32 26 400 Series Frenchwood'_Outsw ng.PaUo Doors fill >` 3180 DP 50 6080 AP/PA DP 40 400 Serves Frenchwood' Sidelights, DP 77 400 Serves FrenchwoodroTransoms DP 77 HGD.R 50 36 x 95 HGD-R 40 71 x 95 SL-LC 77 19 x 96 TR-LC 77 96 x 82 0.02 (.18) 31 26 0.02 (.18) 31 26 <.01 (.18) - • - - t Available with Stormwatch' Protection - including design pressure upgrades. For a copy of the Andersen Coastal Product Guide, contact your Andersen supplier. • Applicable only when DP upgrade kit is installed with factory prefinished white interior units (with prefinished interior trim stop option). •' Did not meet minimum sae requirements for NAFS-02 testing. ^ STC and ORC ratings given are for individual units based on independent tests and represent the entire unit. Higher STC and OITC values may be available with other glazings. Contact Andersen for more information. This data is accurate as of August 12, 2003. Due to ongoing product changes, updated test results, or new industry standards, this data may change over rime. Call your Andersen representative for current performance information or upgrade options. 236