Loading...
Andalusia TR 31681-3 (75 Series; Plans 24 & 25) 2010 Codes - Title 24r-t-d , r } � f c� io �i� � ' consu ti croup,mc., ENERGY CALCULATION (T-24) (Residential Development) Andalusia at Coral Mountain 75' Lots Plan 24 and 25 Tract No. 31681-3 La Quinta, County of Riverside, CA Gouvis Job No.: 63021 1/16/2014 Developer: T.D. Desert Development, Ltd. Architect: Pekarek-Crandell, Inc. � QUID A CITY BUILDING SAFETY �� Eo� CON' `�� )CTION C DATE RECEIVED JAN 2 2 2014 CITY OF LA QUINTA MUNIIY DEVELOPMENT 949.752.1612 Gangyi Zhou, 4400 Campus Drive M34279 Exp. Date 12/31/2014 The attached calculations are valid only when bearing original or o- p Newport Beach, CA electronic signature of Gangyi Zhou, Hereon. 92660 ' www.gouvisgroup.com Hayward, CA Palm Springs, CA Ho Chi Minh City, Vietnam p t l BUILDING ENERGY ANALYSIS REPORT PROJECT: Andalusia At Coral Mountain 75' Lots Plan 4 La Quinta, CA 92253 Project Designer: Pekarek-Crandell, Inc. 31872 Camino Capistrano, Suite 100 San Juan Capistrano, CA 92675 949-487-2320 Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 Job Number: II-KI AI C ! 7 Date:; �, QUINTA ,F„-.-TY DEFT. 1,/16/2014 , J.. ,r— 3 FO€; CJ:v6 I RUC1 iON The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 20b8 Building Energy Efficiency Standards. 1 - -- - - 6yl--- € This program dev`eloped-by EnergyPro 5.1 by EnergySoft User Number., 8165 RunCode: 2014-01-16T20:09:17 ID: 63021 1 I TABLE OF CONTENTS I Cover Page Table of Contents Form CF-1 R Certificate of Compliance Form MF-1 R Mandatory Measures Summary CITY.OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED CONSTRUCTION DATE BY 2 3 11 EnergyPro 5.1 by EnergySoft Job Number: ID: 63021 User Number: 8165 1 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Andalusia At Coral Mountain 75' Lots Plan Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 111612014 Project Address La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,184 Addition r # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features (see Part 2 of 5) Status Wall Wood Framed R-21 2,716 New Roof Wood Framed Attic R-38 4,385 Radiant Barrier New FENESTRATION U- Exterior Orientation Area(fl) Factor SHGC Overhang Sidef ins Shades Status Front (N) 32.0 0.300 0.17 none none Bug Screen New Right (VV) 48.0 0.300 0.20 none none Bug Screen New Right (Vtg 24.0 0.300 0.17 none none Bug Screen New Front (N) 159.5 0.320 0.30 none none Bug Screen New Left (E) 4.5 0.320 0.30 none none Bug Screen New Left (E) 48.0 0.320 0.30 none none Bug Screen New Left (E) 18.0 0.380 0.35 none none Bug Screen New Rear (S) 42.0 0.300 0.17 none none Bug Screen New Rear (S) 18.0 0.300 0.20 none none Bug Screen New Right (IM 440.0 0.320 0.30 none none Bug Screen New Front (N) 80.5 0.320 0.30 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status 1.5 Ton Gas Furance Ducted Ducted Attic, -Ceiling Ins vented-, 8.0 New 2 Ton Gas Furnace Ducted �Ductetl �CeilingJns,,vented 8.0 I `� C.-Aftic, �• ��' "� a A New 4 Ton Gas Furnace Ducted Ducted �- Attic, Ceiling /nsM'v(e�nted T k 8.0 New -;PY0 ED WATER HEATING M �.; � � , Ot . Type Gallons FA- n ' Eff i NS Distribution Status 2 Small Gas 75 0.62 Kitchen Pipe Ins New BY EnergyPro 5.1 by EnergySoft User Number.- 8165 RunCode: 2014-01-16T20:09:17 ID: 63021 Page 3 of 13 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Andalusia At Coral Mountain 75' Lots Plan Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 111612014 Project Address La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,184 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Cavity (ft) Features see Part 2 of 5 Status -Type FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Left (E) 14.5 0.320 0.30 none none Bug Screen New Rear (S) 72.0 0.320 0.30 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status 3 Ton Gas Furnace Ducted Ducted Attic,=Ceiling_Ins,,vented _, 8.0 New N (-;I I Y' OF LA QUiNTA I BUILDING & SAFETY DEPT. WATER HEATING Ot . Type Gallons tt` PPrROVED MiffEff. DN"nistribution Status � M DATE BY N Energ Pro 5.1 by Energ Soft User Number. 8165 RunCode: 2014-01-16T20:09:17 ID: 63021 Pa e 4 of 13 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name Andalusia At Coral Mountain 75' Lots Plan 1 Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 111612014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System 1.5 T Gas Furnace includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 1.5 Ton Gas Furance includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System 1.5 Ton Gas Furance incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System 1.5 Ton Gas Furance includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 1.5 Ton Gas Furance incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System 2 T Gas Fumace includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 2 Ton Gas Fumace includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System 2 Ton Gas Fumace incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System 2 Ton Gas Fumace includes credit for verified adequate airflow. A=cert�bd HERS, rater -must diagnostically measure airflow of the �Y �.r i lcJ�S V 1 /A HVAC System. R 1 E I I i a <.� �, r' „ . •,-� _ The HVAC System 2 Ton Gas Furnace incorporates HERS verifie"d Duct Lea kage. HERS'field verification -and diagnostic testing is required to verify that duct leakage meets the specified criteria. 1" �, +-1 P P. n��- The Cooling System 4 T Gas Fumace includes credit fora 11.0 EER Condehser.A certified,HERS �atet must field verify the installation of the correct �d ��I U(' i IUIN Condenser. The HVAC System 4 Ton Gas Fumace includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. DATE -BY__ I EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2014-01-16T20:09:17 ID: 63021 Page 5 of 13 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name Andalusia At Coral Mountain 75' Lots Plan 1 Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 111612014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. The HVAC System 4 Ton Gas Furnace incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System 4 Ton Gas Fumace includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 4 Ton Gas Fumace incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System 3 T Gas Furnace includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 3 Ton Gas Fumace includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System 3 Ton Gas Fumace incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System 3 Ton Gas Fumace includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 3 Ton Gas Fumace incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. I ,n I"r-% , . A L,-1 A BUILDIN'C & SAFr=---v ncn-r I HUG [ION DATE _ By Ene Pro 5.1 by EnergySoft User Number. 8165 RunCode: 2014-01-16T20:09:17 ID: 63021 Page 6 of 13 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone I Date Andalusia At Coral Mountain 75' Lots Plan 4 ❑ Multi Family ❑ Existing+ Addition/Alteration 1111612014 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV (kBtu/ft2- r) North East South West Space Heating 4.53 4.71 -0.18 4.84 -0.31 3.37 1.15 3.80 0.73 Space Cooling 54.16 49.75 4.41 46.76 7.40 49.78 4.38 51.59 2.57 Fans 10.97 11.20 -0.23 10.62 0.35 11.18 -0.21 11.57 -0.60 Domestic Hot Water 8.72 10.18 -1.46 10.18 -1.46 10.18 -1.46 10.18 -1.46 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 78.38 75.83 2.54 72.40 5.97 74.51 3.87 77.14 1.24 Percent Better Than Standard: 3.2 % 7.6 % 4.9 % 1.6 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 1,362 272 Fuel Available at Site: Natural Gas (E) 390 85 Raised Floor Area: 0 (S) 1,070 132 Slab on Grade Area: 0 (147 895 512 Average Ceiling Height: 10.0 Roof 4,385 0 Fenestration Average U-Factor: 0.32 TOTAL: 1,001 Average SHGC: 0.28 Fenestration/CFA Ratio: 23.9 % REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed Jo comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GMEP Engineers 1/16/2014 Address 4400 Campus Drive Name Gangyi Zhou City/ tate/ZiNewport Beach, CA 92660 Phone 9497521612 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit appl4cab� a d"recognizes-recognizesusing duct design, duct sealing, verification of refrigerant charge, insulation ir%stallation quality, and�build , [envelope sealing require installer testing and certification and field verification by an approved HERS rater. �, •• �, vr-if 4_ .EFTA � Designer or Owner (per Business &� g Professions Code).�r E ; 9r Z Company Pekarek-Crandell, Inc. FOR CONSTRUCTION Address 31872 Camino Capistrano, Suite 100 Name q City/State/Zip San Juan Capistrano, CA 92675 Phone 949-4 A72320---_ BY Signed _ License # Date EnergyPro 5.1 by Ene Soft User Number.- 8165 RunCode: 2014-01-16T20:09:17 ID: 63021 Page 7 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF-1 R Project Name Andalusia At Coral Mountain 75' Lots Plan 4 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1111612014 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 268 0.069 R-21 0 90 New 4.3.1-A6 Castica/Bedroom 4 Wall 158 0.069 R-21 270 90 New 4.3.1-A6 Castica/Bedroom 4 Roof 650 0.025 R-38 0 0 New 4.2.1-A21 Castica/Bedroom 4 Wall 103 0.069 R-21 1 01 90 New 4.3.1-A6 Bedroom 3/Wet Bar/Entry Wall 50 0.069 R-21 90 90 New 4.3.1-A6 Bedroom 3/Wet BarlEntry Roof 625 0.025 R-38 0 0 New 4.2.1-A21 Bedroom 3/Wet BarlEntry Wall 28 0.069 R-21 0 90 New 4.3.1-A6 Kitchen/Dinning/Great Wall 90 0.069 R-21 90 90 New 4.3.1-A6 Kitchen/Dinning/Great Wall 640 0.069 R-21 180 90 New 4.3.1-A6 KtchenlDinninglGreat Wall 76 0.069 R-21 270 90 New 4.3.1-A6 Kitchen/Dinning/Great Roof 1,600 0.025 R-38 0 0 New 4.2.1-A21 Kitchen/Dinning/Great Wall 692 0.069 R-21 0 90 New 4.3.1-A6 Master/Bedroom 2/Laundr Wall 1661 0.069 R-21 90 90 New 4.3.1-A6 Master/Bedroom 2/Laundr Wall 298 0.069 R-21 180 90 New 4.3.1-A6 iMasterlBedroom 2/Laundr Wall 1491 0.069 R-21 2701 90 New 4.3.1-A6 Master/Bedroom 2/Laundr Roof 1,5101 0.025 1 R-38 01 0 New 4.2.1-A21 Master/Bedroom 2/Laundr FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 4.5 0. 3001 NFRC 0.17 NFRC 0 New Casement Castica/Bedroom 4 2 Window 27.5 0.300 NFRC 0.17 NFRC 0 New Casement Castica/Bedroom 4 3 Window 48.0 0.300 NFRC 0.20 NFRC 270 New Fixed Glass Castica/Bedroom 4 4 Window 24.0 0.300 NFRC 0.17 NFRC 270 New Casement Castica/Bedroom 4 5 Window 27.5 0.320 NFRC 0.30 NFRC 0 New I Sliding Glass Door Bedroom 31Wet Bar/Entry 6 Window 4.5 0.320 NFRC 0.30 NFRC 90 New Sliding Glass Door Bedroom 3/Wet Bar/Entry 7 Window 48.0 0.320 NFRC 0.30 NFRC 90 New French Door Bedroom 3/14/et Bar/Entry 8 Window 9.0 0.380 NFRC 0.35 NFRC 90 New Fixed Glass (1) Bedroom 3/Wet Bar/Entry 9 Window 9.0 0.380 NFRC 0.35 NFRC 90 New Fixed Glass (1) Bedroom 31Wet Bar/Entry 10 Window 132.0 0.320 NFRC 0.30 NFRC 0 New Sliding Glass Door Kitchen/Dinning/Great 11 Window 4.5 0.300 NFRC 0.17 1 NFRC 180 New Casement Kitchen/Dinning/Great 12 Window 4.5 0.300 NFRC 0.17 NFRC 180 New Casement Kitchen/Dinning/Great 13 Window 4.5 0.300 NFRC 0.20 NFRC 180 New Fixed Glass Kitchen/Dinning/Great 14 Window 4.5 0.300 NFRC 0.20 NFRC 180 New Fixed Glass Kitchen/Dinning/Great 15 Window 4.5 0.300 NFRC 0.20 NFRC 180 New Fixed Glass KitcherWinning/Great 16 Window 4.5 0.300 NFRC 0.20 NFRC 180 New Fixed Glass Kitchen/Dinning/Great (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin H t Wd Len H t LExt REA Dist Len I H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 f"------ 9 Bug Screen 0.76 N C'_ I"T W 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 J, . r-%} F. 13 Bug Screen 0.76 14 Bug Screen 0.76 15 IBug Screen 0.76 16 JBug Screen 0.76 N f Arm IN EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2014-01-16T20:09:17 ID: 63021 Page 8 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name I Andalusia At Coral Mountain 75' Lots Plan 4 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1111612014 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 17 Mindow 16.5 0.300 NFRC 0.17 NFRC 180 New Casement Kitchen/Dinning/Great 18 Window 16.5 0.300 NFRC 0.17 NFRC 180 New Casement Kitchen/Dinning/Great 19 Window 80.0 0.320 NFRC 0.30 NFRC 270 New Sliding Glass Door Kitchen/Dinning(Great 20 Window 264.0 0.320 NFRC 0.30 NFRC 270 New Sliding Glass Door Kitchen/Dinning(Great 21 Mindow 1 11.0 0.320 NFRC 0.30 NFRC 0 New I Casement(1) MasteNBedroom 2/Laundry 22 Window 11.0 0.320 1 NFRC 0.30 NFRC 0 New Casement(1) MasteNBedroom 2/Laundry 23 Mndow 16.5 0.320 NFRC 0.30 NFRC 0 New Casement(1) Master/Bedroom 2/Laundry 24 Mindow 16.5 0.320 NFRC 0.30 NFRC 0 New Casement(1) MasteNBedroom 21Laundry 25 Mindow 16.5 0.320 NFRC 0.30 NFRC 0 New Casement(1) MasteNBedroom 2/Laundry 26 Mindow 4.5 0.320 NFRC 0.30 NFRC 0 New Casement(1) Master/Bedroom 2(Laundry 27 Window 4.5 0.320 NFRC 0.30 NFRC 0 New Casement(1) Master/Bedroom 2/Laundry 28 Mindow 10.0 0.320 NFRC 0.30 NFRC 90 New Casement(1) MasteNBedroom 2/Laundry 29 Window 4.5 0.320 NFRC 0.30 NFRC 90 New Casement(1) MasteNBedroom 2/Laundry 30 Mndow 72.0 0.320 NFRC 0.30 NFRC 180 New Sliding Glass Door Master/Bedroom 2/Laundry 31 Window 96.0 0.320 NFRC 0.30 NFRC 270 New Sliding Glass Door Master/Bedroom 2/Laundry (1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin H t Wd Len HqA LExt REA Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76-- 24 Bug Screen 0.76 25 Bug Screen 0.76 P a! 1 26 Bug Screen 0.76 - -"``` `" , ,+-t Y D! PT 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 � .;; i ti�� f fOIN] 30 Bug Screen 0.76 31 Bug Screen 0.76 DAT E M EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2014-01-16T20:09:17 ID: 63021 Pa e 9 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name Andalusia At Coral Mountain 75' Lots Plan Building Type © Single Family ❑ Addition Alone 4 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 111612014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area Volume Year Built New Existing Altered Removed 1.5 Ton Gas Furance Area 620 6,200 2 Ton Gas Furnace Area 614 6,140 4 Ton Gas Furnace Area 11420 14,200 3 Ton Gas Fumace Area 1,530 15,300 Totals 1 4,184 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status 1.5 Ton Gas Furance 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New 2 Ton Gas Furnace 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New 4 Ton Gas Furnace 1 Central Furnace 80 % AFUE Split Air Conditioner 13.0 SEER Setback New 3 Ton Gas Furnace 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Cooling Duct Location Duct R-Value Ducts Tested? Status 1.5 Ton Gas Furance Ducted Ducted Attic, Ceiling Ins, vented 8.0 0 New 2 Ton Gas Furnace Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New 4 Ton Gas Furnace Ducted Ducted Attic, Ceiling Ins, vented 8.0 New 3 Ton Gas Furnace Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 75 gal or Le 2 Small Gas Kitchen Pipe Ins 75,000 75 0.62 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length,,' ft w `.'to , ; a — QUINTA & SkFEI DEPT. �, _' ;,S stem Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside BLJjLC � Buried' ` r-() i OC,Nc3 i RI rt^�rnn► N ❑ -. C ATP ❑ N yI EnergyPro 5.1 by EnergySoft User Number., 8165 RunCode: 2014-01-16T20:09:17 ID: 63021 Page 10 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name Andalusia At Coral Mountain 75' Lots Plan 4 Date 1 111612014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM Ell 677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from 2hysical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine-lines),and-piping insulated between -heating water tank shall be insulated to Table 150-B and Equation 150-,� ffV (`_': 1 F�, n i I l KITA source and indirect hot I §1500)2: Pipe insulation for steam hydronic heating systems! or hot water systems >15 p§i, meets;.the requirements 123-A. bviILLA, a.a �fi L Il�t� l . of Standards Table 150 ' 3A: Insulation is protected from damage, including that due to sunli' he, moisture, e` ui ment mairitenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant uction(linesincludes-a vapo retardant or is conditioned space. enclosed entirely in 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. t�iw 1 i7 Y 1 EnergyPro 5.1 by EnergySoR User Number: 8165 RunCode: 2014-01-16T20:09:17 ID: 63021 Page 11 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Andalusia At Coral Mountain 75' Lots Plan 4 111612014 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500.ftz or_100,watts-for-dwelling-units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy�luminaires in the kitcFen�are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a� multi -scene programmable_.co'ntrol system;sand all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet,!and.utility"rooms are, igKefficacy and controlled by a manual -on occupant sensor. I „ .-­� ,- A t -: r. w +!= n N §150(k)9: Permanently installed lighting that is internal to cabinets shalGuse no more than ::20-watts of power per linear foot of illuminated cabinet. M FOR CONS I HUU I 1V14 DATE ____----- BY EnergyPro 5.1 by EnergySoft User Number.' 8165 RunCode: 2014-01-16T20:09:17 ID: 63021 Page 12 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Andalusia At Coral Mountain 75' Lots Plan 4 1 111612014 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130 d . §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY OF L,� QUINTA BUILDING i3 S,6.: E _'.�Y DEPT. P +> �I', �_/ � D FOR CONSTRUCTION DATE BY EnergyPro 5.1 by EnergySoR User Number: 8165 RunCode: 2014-01-16T20:09:17 ID: 63021 Page 13 of 13 BUILDING ENERGY ANALYSIS REPORT PROJECT: Andalusia At Coral Mountain 75' Lots Plan 5 La Quinta, CA 92253 Project Designer: Pekarek=Crandell, Inc. 31872 Camino Capistrano, Suite 100 San Juan Capistrano, CA 92675 949-487-2320 Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 Job Number: 63021 Cl_�a n1F LA aij INiT Date: S - —V oEP. gl3tLUlrvv 1/FOR- 0�1�4�STRUC, N The EnergyPro computer program has been used to perform the calculations summarized`in-this-complianreport. This program has approval and is authorized by the California Energy Commission for use with both't�dent— ia�l�anlonresiderital£4e 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by Energ Soft User Number: 8165 RunCode: 2014-01-16T19:52:23 ID: 63021 I TABLE OF CONTENTS I Cover Page Table of Contents Form CF-1 R Certificate of Compliance Form MF-1 R Mandatory Measures Summary CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE __- ---- BY 2 3 12 I EnergyPro 5.1 by EnergySoft Job Number: ID: 63021 User Number: 8165 1 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Andalusia At Coral Mountain 75' Lots Plan Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 111612014 Project Address La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,331 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Wall Wood Framed R-21 3,511 New Roof Wood Framed Attic R-30 4,331 Radiant Barrier New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidef ins Shades Status Front (N) 76.0 0.300 0.17 none none Bug Screen New Left (E) 44.0 0.300 0.17 none none Bug Screen New Left (E) 3.1 0.300 0.20 none none Bug Screen New Right (Ko 48.0 0.320 0.30 none none Bug Screen New Rear (S) 24.0 0.360 0.35 none none Bug Screen New Front (N) 35.4 0.320 0.30 none none Bug Screen New Right (W 96.0 0.320 0.30 none none Bug Screen New Rear (S) 120.4 0.300 0.17 none none Bug Screen New Front (N) 8.0 0.300 0.20 none none Bug Screen New Front (N) 27.5 0.300 0.20 none none Bug Screen New Left (E) 180.0 0.320 0.30 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status 1.5 Ton Gas Furnace Ducted Ducted Attic, Ceiling Ins, vented 8.0 New 2 Ton Gas Furnace Ducted Ducted r--Attic;-Ceiling'Ins`vented 8.0 New 5 Ton Gas Furnace Ducted K . Ducted � �<Attiq Ceiling'.. 'r h lns, vent�edK--'i U 11 *4 1 1 _ 8.0 New WATER HEATING t3UiLt kV i G -'x.=c ` 1 L�L:r' i . Ot . Type Gallons Min. Eff ADistrib.utiori _.._ C Status 2 Small Gas 75 0.621 F077'eh�e}n Pipe Ins�ju 1 �U" A New DATE DY Energ Pro 5.1 by EnergySoft User Number: 8165 RunCode: 2014-01-16T19:52:23 ID: 63021 Page 3 of 14 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Andalusia At Coral Mountain 75' Lots Plan Building Type to Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 111612014 Project Address La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,331 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST 0 Yes ❑ No HERS Measures -- If Yes, A CF-413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidef ins Shades Status Left (E) 48.0 0.320 0.30 none none Bug Screen New Left (E) 3.1 0.380 0.35 none none Bug Screen New Front (N) 312.0 0.320 0.30 none none Bug Screen New Front (N) 9.0 0.300 0.17 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status 1.5 Ton Gas Fumace Ducted Ducted (--Attic;`Ceiling Ins, -vented- --�8. 0 New ul I Y (-)I- LJA WIN (A p bUILU:-16 & 8,- lFETY DEPT. M WATER HEATING Ot . Type Gallons Min. Eff )R 0itributidifICN Status N 'DATE BY N Energ Pro 5.1 by EnergySoft User Number.' 8165 RunCode: 2014-01-16T19:52:23 ID: 63021 Page 4 of 14 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name Andalusia At Coral Mountain 75' Lots Plan Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration16,12014 7Date SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. The Roof R-30 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System 1.5 T Gas Furnace includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 1.5 Ton Gas Furnace includes credit for Verged Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System 1.5 Ton Gas Furnace incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System 1.5 Ton Gas Furnace includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 1.5 Ton Gas Furnace incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System 2 T Gas Furnace includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 2 Ton Gas Furnace includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System 2 Ton Gas Furnace incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System 2 Ton Gas Furnace includes credit for verified adequate'�airflow.`O certified, HERSAMter must diagnostically HVAC System. measure airflow of the The HVAC System 2 Ton Gas Furnace incorporates HERS verified Duct Leakage. _HERS -field verification and"diagnostic,testing is required to verify that duct leakage meets the specified criteria. ,f \, J � J.— . _ V F 0 The Cooling System 5 T Gas Furnace includes credit fora 11.0 EER C ndenser certified HERS_ dater` mu yld veril the installation of the correct Condenser. The HVAC System 5 Ton Gas Furnace includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.158 w/cfm. OATS — SY EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2014-01-16T19:52:23 ID: 63021 Page 5 of 14 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name Andalusia At Coral Mountain 75' Lots Plan 1 Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 111612014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. The HVAC System 5 Ton Gas Furnace incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System 5 Ton Gas Furnace includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 5 Ton Gas Fumace incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System 1.5 T Gas Furnace includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 1.5 Ton Gas Fumace includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System 1.5 Ton Gas Fumace incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System 1.5 Ton Gas Fumace includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 1.5 Ton Gas Fumace incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. _ CITY OF IA i U 11'q y r-k ,— n nr.-,-i-v DEFT- t3UIL-L-0W•� — —' -- — FOR CONSTRUCTiON nnTF BY EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2014-01-16T19:52:23 ID: 63021 Page 6 of 14 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone I Date Andalusia At Coral Mountain 75' Lots Plan 5 ❑ Multi Family ❑ Existing+ Addition/Alteration I 1111612014 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kBtu/ft2- r) North East South West Space Heating 5.28 5.66 -0.39 5.29 -0.02 5.31 -0.03 5.87 -0.59 Space Cooling 56.17 47.39 8.78 51.05 5.12 51.87 4.30 50.82 5.36 Fans 11.48 10.89 0.58 11.67 -0.19 11.82 -0.34 11.59 -0.12 Domestic Hot Water 5.48 6.48 -1.00 6.48 -1.00 6.48 -1.00 6.48 -1.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 78.41 70.43 7.98 74.49 3.92 75.48 2.93 74.76 3.65 Percent Better Than Standard: 10.2 % 5.0 % 3.7 % 4.7 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 2,010 468 Fuel Available at Site: Natural Gas (E) 855 278 Raised Floor Area: 0 (S) 1,170 144 Slab on Grade Area: 0 (►M 510 144 Average Ceiling Height: 10.8 Roof 4,331 0 Fenestration Average U-Factor: 0.32 TOTAL: 1,035 Average SHGC: 0.27 Fenestration/CFA Ratio: 23.9 % REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GMEP Engineers 1/16/2014 Address 4400 Campus Drive Name Gangyi Zhou City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone 9497521612 Signed Date The individual with overall design responsibility hereby certifies=that-the,proposed-buildin -- esign represented in this set of construction documents is consistent with the other ance'#ormsland worksheets,�wit, the specifications, and pcoiQp with any other calculations submitted with this permit application.! and recognizes that eompliance using duct design, duct sealing, verification of refrigerant charge, insulation instal-latiori quality; andibuilding envelope sealing require installer testing and certification and field verification by an approved HERS rater MOE CONSTRUCTION Designer or Owner (per Business & Professions Code) Company Pekarek-Crandell, Inc. DATE 13Y Address 31872 Camino Capistrano, Suite 100 Name City/State/Zip San Juan Capistrano, CA 92675 Phone 949-487-2320 Signed License # Date EnergyPro 5.1 by Ene ySoft User Number: 8165 RunCode: 2014-01-16T19:52:23 ID: 63021 Page 7 of 14 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF-1 R Project Name I Andalusia At Coral Mountain 75' Lots Plan 5 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1111612014 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 256 0.069 R-21 0 90 New 4.3.1-A6 Bedroom 4/Casita Wall 185 0.069 R-21 90 90 New 4.3.1-A6 Bedroom 4/Casita Wall 1621 0.069 R-21 270 90 New 4.3.1-A6 Bedroom 4/Casita Wall 276 0.069 R-21 180 90 1 New 4.3.1-A6 Bedroom 4/Casita Roof 562 0.031 R-30 0 0 New 4.2.1-A20 Bedroom 4/Casita Wall 115 0.069 R-21 0 90 New 4.3.1-A6 Master Suite/Hall1 Wall 69 0.069 R-21 270 90 New 4.3.1-A6 Master Suite/Hall1 Wall 443 0.069 R-21 180 90 New 4.3.1-A6 Master Suite/Hall 1 Roof 1,182 0.031 R-30 0 0 New 4.2.1-A20 Master Suite/Hall 1 Wall 587 0.069 R-21 0 90 New 4.3.1-A6 Great Room/Kitchen/Mom Wall 294 0.069 R-21 90 90 New 4.3.1-A6 Great Room/Kitchen/Mom Wall 298 0.069 R-21 0 90 New 4.3.1-A6 Great Room/Kitchen/Mom Roof 1,650 0.031 R-30 0 0 New 4.2.1-A20 Great Room/Kitchen/Mom Wall 287 0.069 R-21 0 90 New 14.3.1-A6 1 Bedroom 2&3lLaundry Wall 98 0.069 R-21 90 90 New 14.3.1-A6 Bedroom 2&3lLaundry Wall 1 1351 0.069 1 R-21 2701 90 New 14.3.1-A6 Bedroom 2&3/Laundry FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 11.0 0.300 NFRC 0.17 NFRC 0 New Casement Bedroom 4/Casita 2 Window 11.0 0.300 NFRC 0.17 NFRC 0 New Casement Bedroom 4/Casita 3 Window 11.0 0.300 NFRC 0.17 NFRC 0 New Casement Bedroom 4/Casita 4 Window 11.0 0.300 NFRC 0.17 NFRC 0 New Casement Bedroom 4/Casita 5 Window 22.0 0.300 NFRC 0.17 NFRC 90 New I Casement Bedroom 4/Casita 6 Window 3.1 0.300 1 NFRC 0.20 NFRC 90 New Fixed Glass Bedroom 4/Casita 7 Window 48.0 0.320 NFRC 0.30 NFRC 270 New French Door Bedroom 4/Casita 8 Window 24.0 0.380 NFRC 0.35 NFRC 180 New French Door(1) Bedroom 4/Casita 9 Window 11.8 0.320 NFRC 0.30 NFRC 0 New Casement(1) Master Suite/Hall 1 10 Window 11.8 0.320 NFRC 0.30 NFRC 0 New Casement(1) Master Suite/Hall 1 11 Window 11.6 0.320 NFRC 0.30 NFRC 0 New Casement(1) Master Suite/Hall 1 12 Window 96.0 0.320 NFRC 0.30 NFRC 270 New Sliding Glass Door Master Suite/Hall 1 13 Window 4.5 0.300 NFRC 0.17 NFRC 180 New Casement Master Suite/Hall 1 14 Window 11.8 0.300 NFRC 0.17 NFRC 180 New Casement Master Suite/Hall 1 15 Window 11.8 0.300 NFRC 0.17 NFRC 180 New Casement Master Suite/Hall 1 16 Window 11.8 0.300 NFRC 0.17 1 NFRC 180 New Casement Master Suite/Hall 1 (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Ri ht Fin H t Wd Len H t LExt RExt Dist Len Hat Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 a A r „i I ! t Fr IA 9 Bug Screen 0.76 � � ° ' M 10 Bug Screen 0.76 r UILU Ivu G z)Pr• I Y L LH I . N 11 Bug Screen 0.76 /! r- N 12 Bug Screen 0.76'-- 13 Bug Screen 0.76 ram'"1 l�lyi� 7 y tilJ'v l llihV 14 Bug Screen 0.76 15 Bug Screen 0.76 , T� _ 16 Bug Screen 0.76 - " - EnergyPrio 5.1 by EnergySoft User Number.- 8165 RunCode: 2014-01-16T19:52:23 ID: 63021 Page 8 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Andalusia At Coral Mountain 75' Lots Plan 5 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 111612014 OPAQUE SURFACE DETAILS Surface Type Area Ll- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavit Exterior Frame Interior Frame Wall 307 0.069 R-21 180 90 New 4.3.1-A6 Bedroom 2&3/Laundry Roof 937 0.031 R-30 0 0 New 4.2.1-A20 Bedroom 2&3/Laundry FENESTRATION SURFACE DETAILS ID Type Area LI-Factor SHGCz Azm Status Glazing Type Location/Comments 17 Window 4.5 0.300 NFRC 0.17 NFRC 180 New Casement Master Suite/Hall 1 18 Window 16.5 0.300 NFRC 0.17 NFRC 180 New Casement Master Suite/Hall 1 19 Window 16.5 0.300 NFRC 0.17 NFRC 180 New Casement Master Suite/Hall 1 20 Window 4.0 0.300 NFRC 0.20 NFRC 0 New Fixed Glass Great RoomlKitchenAWorninglE 21 Window 4.0 0.300 NFRC 0.20 NFRC 0 New Fixed Glass Great Room/Kitchen/Morning/ 22 Window 27.5 0.300 NFRC 0.17 NFRC 0 New Casement Great Room/Kitchen/Morning/ 23 Window 27.5 0.300 NFRC 0.20 NFRC 0 New Casement(2) Great RoornXitchen/Morning/ 24 Window 108.0 0.320 NFRC 0.30 NFRC 90 New Sliding Glass Door Great Room/Kitchen/Morning/ 25 Window 48.0 0.320 NFRC 0.30 NFRC 90 New French Door Great Room/Kitchen/Morning/ 26 Window 3.1 0.380 NFRC 0.35 NFRC 90 New Fixed Glass(1) Great Room/Kitchen/Momin 27 Window 72.0 0.320 NFRC 0.30 NFRC 90 New Sliding Glass Door Great Room/Kitchen/Momin ' 28 Window 96.0 0.320 1 NFRC 0.30 NFRC 0 New Sliding Glass Door Great Room/Kitchen/Moming/ 29 Window 216.0 0.320 NFRC 0.30 NFRC 0 New Sliding Glass Door Great Room/Kitchen/Morning/ 30 Window 4.5 0.300 NFRC 0.17 NFRC 0 New Casement Bedroom 2&3/Laundry 31 Window 4.5 0.300 NFRC 0.17 NFRC 0 New Fixed Glass(2) Bedroom 2&3/Laundry 32 Window 4.5 0.300 NFRC 0.17 NFRC 0 New Fixed Glass(2) Bedroom 2&3/Laundry (1) LI-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin H t Wd Len Hcit I LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 lBug, Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 t-- �-� "-_ -_ 25 Bug Screen 0.76 ;!) Y ( It 1- JA t- � u i ) 4 1 PC 26 Bug Screen 0.76 r , E i i i-% n , n Q n c- TV r I= PT N 27 Bug Screen 0.76 M 28 Bug Screen 0.76 29 Bug Screen 0.76 ^Tl(` N M 30 Bug Screen 0.76 _ N 31 Bug Screen 0.76 N N 32 Bug Screen 1 0.761 1 n �TF Ener Pro 5.1 by EnergySoft User Number. 8165 RunCode: 2014-01-16T19:52:23 ID: 63021 Page 9 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name I Andalusia At Coral Mountain 75' Lots Plan 5 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration I Date 1111612014 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 22.0 0.300 NFRC 0.17 NFRC 90 New Casement Bedroom 2&3/Laundry 34 Window 11.0 0.300 NFRC 0.17 NFRC 180 New Casement Bedroom 2&3/Laundry 35 Window 4.5 0.300 NFRC 0.17 NFRC 180 New Casement Bedroom 2&NLaundry 36 Window 27.5 0.300 NFRC 1 0.17 NFRC 180 New Casement Bedroom 2&3/Laundry (1) LI-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Overhang Left Fin Right Fin Hat Wd Len H t LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 L A I Y � F. !�+ � I I K 11' A I I �r";rz ^runic: rr��eE�,r-�n�r I M I DATc Rv I 1 — EnergyPro 5.1 by EnergySoft User Number. 8165 RunCode: 2014-01-16119:52:23 ID: 63021 Pa a 10 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name Andalusia At Coral Mountain 75' Lots Plan I Building Type 0 Single Family ❑ Addition Alone 5 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1111612014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area Volume Year Built New Existing Altered Removed 1.5 Ton Gas Furnace Area 562 5,620 2 Ton Gas Furnace Area 1,182 11,820 5 Ton Gas Furnace Area 1,650 19,800 1.5 Ton Gas Furnace Area 937 9,370 Totals 4,331 01 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status- 1. 5 Ton Gas Furnace 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New 2 Ton Gas Furnace 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New 5 Ton Gas Furnace 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New 1.5 Ton Gas Furnace 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Cooling Duct Location Duct R-Value Ducts Tested? Status 1.5 Ton Gas Fumace Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New 2 Ton Gas Furnace Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New 5 Ton Gas Furnace Ducted Ducted Attic, Ceiling Ins, vented 8.0 El New 1.5 Ton Gas Furnace Ducted Ducted Attic, Ceiling Ins, vented 1 8.01 m New WATER HEATING SYSTEMS S stem Name at . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 75 gal or Le 2 Small Gas Kitchen Pipe Ins 75,000 75 0.62 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft _ A Pi a Length Pipe Diameter Insul. Thick. OF LA QUIN1 !N & SAFFE TY DEFT. lo c s stem Name' 100 y Q r � Qty. HP Plenum Outside B; Buried ❑ N DA F113_ BY 1— —9- EnergyPro 5.1 by Ener Soft User Number- 8165 RunCode: 2014-01-16T19:52:23 ID: 63021 Pa a 11 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name Andalusia At Coral Mountain 75' Lots Plan 5 Date 1 111612014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. *§150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM El677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no areater than 2.0perm/inch and shall be protected from Rhysical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems; and entire length of recirculating sections of hot water pipes are insulated per Standards -Table'll50'6. , , t.: i l % fT A M §1500)2: Cooling system piping (suction, chilled water, or Y brinelines);and piping:insulated'between"tieatng� sourc A. e and indirect hot water tank shall be insulated to Table 150-B and E nation 150-, , +a+� �At j ; DER I §1500)2: Pipe insulation for steam hydronic heating systems or hot water,systems >15-psi, meetsAhe requirements of Standards Table 123-A. / - : • _� € ' , �t_Li, . N 150 ' 3A: Insulation is protected from damage, including that due to suh- ht,Qoisture, e ° u 'me t maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certifier b' ytKd—Solar Ratio vand=Certification-Oor oration. EnergyPro 5.1 by EnergySoR User Number., 8165 RunCode: 2014-01-16T19:52:23 ID: 63021 Page 12 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Andalusia At Coral Mountain 75' Lots Plan 5 1 111612014 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500. ft2 or 100 wafts larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low�efficacy�lumrrai�rs in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi scene programmable control'system; a d all permanently installed luminaries in garages, laundry rooms, closets greater than 70�square feet; and utilityjooms are,high efficacy and controlled by a manual -on occupant sensor.-- §150(k)9: Permanently installed lighting that is internal to cabinets shalFu96 no more -than 204vatts of pc per linear foot of Aer illuminated cabinet. F R G%ONSTRUC;TION DATE _,— -- — BY EnergyPro 5.1 by EnergySoff User Number: 8165 RunCode: 2014-01-16Ti9:52:23 ID: 63021 Page 13 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Andalusia At Coral Mountain 75' Lots Plan 5 111612014 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130 d . §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY 01F LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2014-01-16T19:52:23 ID: 63021 Page 14 of 14