Andalusia TR 31681 BTCP2017-0003 (Plans 24-26) 2016 Code Update - Certificate of Compliance• CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
r
Project Name: Plan 24 Residence Calculation Date/Time: 08:07, Thu, Jun 29, 2017
Calculation Description: Title 24 Analysis - Input File Name: Plan 24-Andalusia-17.ribd16x
CF1R-PRF-61
Page 1 of 10,E <, "
GENERAL INFORMATION
01
Project Name
Plan 24 Residence
02
Calculation Description
Title 24 Analysis
03
Project Location
Coral Mountains
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager.Version
BEMCmpMgr 2016.2.1 (695)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.1
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft)
4184
15
Number of Zones
1
16
Slab Area (ft)
4184
17
Number of Stories
1
18
Addition Cond. Floor Area
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ft2'
n/a
21
Glazing Percentage (%)[20,39/6
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
.
02
This building incorporates features that require field testing.a d/o�lverification*"b aY certified HERS raterpunder the supervision' of a CEC-a roved HERS provider.
.. ., ti �P ., Pp
03
This building incorporates one or more*-', Special Feat ru es shown below
`y �--� P R 0 V I
Q E R.
v
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE $ 1 BY v'
/,�y^//
r LANJ
_
Registration Number: 217-P010002453C-000-000-0000000-0000 Registration Date/Time: 2017-06-29 09:14:27
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695
RECEIVED
JUN 14 2017
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
I&
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-29 08:09:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project.Name: Plan 24 Residence Calculation Date/Time: 08:07, Thu, Jun 29, 2017
Calculation Description: Title 24 Analysis Input File Name: Plan 24-Andalusia-17.ribdl6x
CF1 R-PRF-61
Page 2 of 10
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.92 2.20
-0.28
-14.6%
Space Cooling
82.15 71.76
10.39
12.6%
IAQ Ventilation
0.79 0.79
0.00
0.0%
Water Heating
3.14 9.09
-5.95
.-189.5%
PV Credit
---- 0.00
0.00
----
North Facing Compliance Total
88.00 83.84
4.16
4.7%
Space Heating
1.92 2.42
-0.50
-26.0%
Space Cooling
82.15 71.68
10.47
12.7%
IAQ Ventilation
0.79 0.79
0.00
0.0%
Water Heating
3.14 9.09
-5.95
-189.5%
PV Credit
---- 0.00
0.00 .
---
East Facing Compliance Total
88.00 83.98
4.02
4.6%
Space Heating ''-
1.92 2.54
-0.62
-32.3%
Space Cooling
822..15 69�49 Cnc
0�
12.66
0.00
15.4%
0.0%Water
IAQ Ventilation79
Heating
T14 e9109
�p/
-5.95
-189.5%
PV Credit
H
E -- R S i R 0 o 00 1
E)
0.00
----
South Facing Compliance Total
88.00 81.91
6.09
6.9%
Space Heating
1.92 2.55
-0.63
-32.8%
Space Cooling
82.15 69.50
12.65
15.4%
IAQ Ventilation
0.79 0.79
0.00
0.0%
Water Heating
3.14 9.09
-5.95
-189.5%
PV Credit .
---- 0.00
0.00
---
West Facing Compliance Total
88.00 81.93
6.07
6.9%
Registration Number: 217-Po10002453C-000-000-0000000-000o Registration Datefrime: 2017-06-29 09:14:27
CA Building Energy Efficiency Standards - 2016 Residential Compliance, Report Version - CF1 R-05232017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-29 08:09:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 24 Residence Calculation Date/Time: 08:07, Thu, Jun 29, 2017
CF1R-PRF-01
Page 3 of 10
Calculation Description: Title 24 Analysis
Input File Name: Plan 24-Andalusia-17.ribdl6x
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy.Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC). A score of zero represents the energy performance of a building
that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6
(such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under
Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV
Final EDR of Proposed Design
North
49.6
47.7
0.0
47.7
East
49.6
47.8
0.0
47.8
South
49.6
46.9
0.0
46.9
West
49.6
46.9
0.0
46.9
❑
Design meets Tier 1 requirement of .15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requiremen't of 30% or -greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
for in cliimate one CZF15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
Design meets Zero Net Energy (ZNE) Design, Designation requirement,Sin
photovoltaic (PV) renewable energy generation sufficient�to„achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified.
REQUIRED SPECIAL FEATURES ' f �n%.0 'a A U U H %s a
The following are features that must be installed as condition%for meetiMnglth%mmodeled ene rgy perfo„mance,fo�this computer analysis. � C>
• Cool roof
• Insulation above roof deck
• Window overhangs and/or fins
• Pipe insulation, all lines
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
--None--.-
Registration Number: 217-P010002453C-000-000-0000000-0000 Registration Date/Time: 2017-06-29 09:14:27 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-05232017-695 Report Generated at: 2017-06-29 08:09:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 24 Residence Calculation Date/Time: 08:07, Thu, Jun 29, 2017
Calculation Description: Title 24 Analysis Input File Name: Plan 24-Andalusia-17.ribdl6x
CF1R-PRF-01
Page 4 of 10
BUILDING - FEATURES. INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 24 Residence
4184
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
residence
Conditioned
HVAC1
4184
9
DHW Sys 1
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
} d lione
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft)
Tilt (deg)
N Wall
f residences f
R-21 Wall (W.21.2x6.16)
0
Front
1280
184.5
90
E Wall
residence,;. - " .OftRj21
V all.,(W.21.2x6A6), M
Im,.90
1,Left
920
91
90
S Wall
re§ide�rice C! <
R 2�]Wall (W�21..2x6 16)�
180
{Back, 0
1280
171
90
W Wall
t' J r �'re`ide`nce �R►•
J R""21�Wall,(W 2J..2x6! 16)A
—271) $I
1Right
� is 920
428
90
Roof
` t residences k._A
K: ®R-38&Roof Attie M
,-N % / JVA
r-.t 1C C
, 4184
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic residence
Attic Roofresidence
Ventilated
3
0.3
0.75
Yes
Yes
Registration Number: 217-PO10002453C-000-000-0000000-0000 Registration Date/Time: 2017-06-29 09:14:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-29 08:09:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 24 Residence Calculation Date/Time: 08:07, Thu, Jun 29, 2017
Calculation Description: Title 24 Analysis
Input File Name: Plan 24-Andalusia-17.ribdl6x
CF1 R-PRF-61
Page 5 of 10
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
10 ---- .32.30
Window
N Wall (Front-0)
6.0
12.0
1
72.0
0.32
0.30
Insect Screen (default)
21 ---- .32.30
Window
N Wall (Front-0)
2.0
5.5
1
11.0
0.32
0.30
Insect Screen (default)
22 ---- .32.30
Window
N Wall (Front-0)
2.0
5.5
1
11.0
0.32
0.30
Insect Screen (default)
23 ---- .32.30
Window
N Wall (Front-0)
3.0
5.5
1
16.5
0.32
0.30
Insect Screen (default)
24 ---- .32.30
Window
N Wall (Front-0)
3.0
5.5
1
16.5
0.32
0.30
Insect Screen (default)
25 ---- .32.30
Window
N Wall (Front-0)
3.0
5.5
1
16.5
0.32
0.30
Insect Screen (default)
26 ---- .32.30
Window
N Wall (Front-0)
1.5
3.0
1
4.5
0.32
0.30
Insect Screen (default)
27 ---- .32.30
Window
N Wall (Front-0)
1.5
3.0
1
4.5
0.32
0.30
Insect Screen (default)
1 ----- .30.17
Window '
N Wall (Front-0)
1.5
3.0
1
4.5
0.30
0.17
Insect Screen (default)
2 ----- .30.17
Window
N Wall (Front-0)
5.0
5.5
1
27.5
0.30
0.17
Insect Screen (default)
28 ---- .32.30
Window
E Wall (Left-90)
---
----
1
10.0
0.32
0.30
Insect Screen (default)
29 ---- .32.30
Window
rE-Wall (Lef�-'90)� !f I
�2% -5-2 P
P*----
1
_4.5
0.32
0.30
Insect Screen (default)
7 ---- .32.30
Window
('� E Wallc(WUM 4
----y�;---�
d(' i
48.0
0.32
0.30
Insect Screen (default)
6 ---- .32.30
Window
�E=Wall�(Left`-90)i`--A L*= t.
U----U r
;
U U1 U
-4/9
0.32
0.30
Insect Screen (default)
16 ---- .30.17
Window
9-Wall (BackpiD) 5 P
R-yO
V --1
D 1E
R 4.5
0.30
0.17
Insect Screen (default)
15 ----- .30.17
Window
S Wall (Back-180)
----
----
1
4.5
0.30
0.17
Insect Screen (default)
14 ----- .30.20
Window
S Wall (Back-180)
----
-
1
4.5
0.30
0.20
Insect Screen (default)
13 ----- .30.20
Window
S Wall (Back-180)
----
----
1
4.5
0.30
0.20
Insect Screen (default)
12 ----- .30.20
Window
S Wall (Back-180)
----
----
1
4.5
0.30
0.20
Insect Screen (default)
11 ----- .30.20
Window
S Wall (Back-180)
----
----
1
4.5
0.30
0.20
Insect Screen (default)
17 ---- .30.17
Window
S Wall (Back-180)
----
----
1
72.0
0.30
0.17
Insect Screen (default)
18 ----- .30.17
Window
S Wall (Back-180)
----
----
1
72.0
0.30
0.17
Insect Screen (default)
19 ---- .32.30
Window
W Wall (Right-270)
8.0
10.0
1
80.0
0.32
0.30
Insect Screen (default)
20 ---- .32.30
Window
W Wall (Right-270)
21.0
12.0
1
252.0
0.32
0.30
Insect Screen (default)
31 ---- .32.30
Window
W Wall (Right-270)
12.0
8.0
1
96.0
0.32
0.30
Insect Screen (default)
Registration Number: 217-P010002453C-000-000-0000000-0000 Registration Datefrime: 2017-06-29 09:14:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-29 08:09:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 24 Residence Calculation Date/Time: 08:07, Thu, Jun 29, 2017
Calculation Description: Title 24 Analysis Input File Name: Plan 24-Andalusia-1 7.ribdl 6x
CF1 R-PRF-61
Page 6 of 10
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door
E Wall
24.0
0.50
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
10 ---- .32.30
18
0.1
18
18
0
0
0
0
0
0
0
0
0
21 ---- .32.30
6
0.1
6
6
0
0
0
0
0
0
0
0
0
22 ---- .32.30
6
0.1
6
6
0
0
0
0
0
0
0
0
0
23 ---- .32.30
61,f
OA
6
6
0
0
0
0
0
0
0
0
0
24 ---- .32.30
•6 1.
,- 0.1
6
6
0
0
0
0
0
0
0
0
0
25 ---- .32.30 �`
4` 6
-0.1,-
6
6
0-0
0_
0
0
0
0
0
0
26 ---- .32.30
rT6
-b.1
6 ram
0�
0 �
OH A
� Ow"
0
0
0
0
0
27 -- .32.30
6r.' R
. \k �
�_. 6�
y��+ t6'
i9 `6 ___
O0
q11
i� 0...
e+ 0 It
0.�__
._. 0
0
0
0
0
1 ---- .30.17
` $
0.1
a e8 e—
a-� 8 R—
r� 4
,� 1. 1
�r 0,r,~
a-- or,
0
0
0
0
0
2 ----- .30.17
8
06.1
it 18 L—
i -% 8 "9
rr0 r Z
% -'0 V
It 01,'
L— Orr
0
0
0
0
0
19 ---- .32.30
8
0.1
8
8.
0
0
0
0
0
0
0
0
0
20 ---- .32.30
18
0.1
18
18
0
0
0
0
0
0
0
0
0
31 ---- .32.30
18
0.1
18
18
0
0
0
0
0
0
0
0
0
Registration Number: 217-Po10002453C-000-000-0000000-0000 Registration Date/Time: 2017-06-29 09:14:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-29 08:09:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 24 Residence Calculation Date/Time: 08:07, Thu, Jun 29, 2017
CF1R-PRF-61
Page 7 of 10
Calculation Description: Title 24 Analysis
Input File Name: Plan 24-Andalusia-1 7.ribdl 6x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
• Cavity / Frame: no insul. / 2x4 Top Chrd
• Roof Deck: Wood Siding/sheathing/decking
2x4 Top Chord of Roof Truss @ 24
Above Deck Insulation: R10 Sheathing
Attic Roofresidence
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.086
Rooting: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
SLAB FLOORS
01
�, 02
03
04
OS
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab ex
residence ��
41F t
266
_ None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION AA A f-- N A I ,+I „� N I K C w
01
�_ ..
% r. r
a a w-- n-02 R-- am
* % �a V-�. 403 r-%
Ifr
04
Quality Insulation Installation (QII)
``Quality installation of°Spray Foamrinsulation
r VBuifding'Envelope Air Leakage
CFM50
Required
Not Required
Not Required
--
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1 (2)
2
WATER HEATERS
01
02
03
.04
05
06
07
08
09
10
11
Tank
Energy
Tank Insulation
Tank Location or
Heater
Number
Volume
Factor or
Input
R-value
Standby Loss I
Ambient
Name
Element Type
Tank Type
of Units
(gal)
Efficiency
Rating/Pilot
(IntlExt)
Recovery Eff
NEEA Heat Pump Type
Condition
DHW Heater 1
Gas
Large Storage
2
75
0.76 frac
76,000 Btu/hr
R-0
0.02
/n
n/a
Registration Number: 217-P010002453C-000-000-0000000-0000 Registration Date/Time: . 2017-06-29 09:14:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-05232017-695 Report Generated at: 2017-06-29 08:09:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 24 Residence Calculation Date/Time: 08:07, Thu, Jun 29, 2017
CF1 R-PRF-61
Page 8 of 10
Calculation Description: Title 24 Analysis
Input File Name: Plan 24-Andalusia-17.ribd16x
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC1
Heat Pump Heating and
Cooling System
Heat Pump System 1
Heat Pump System 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEAT PUMPS
01
02
03
04
05
06
07
08
09
10
11
Name
System
Type
Number of
Units
Heating.
Cooling
Zonally
Controlled
Compressor
Type
HERS
Verification
HSPF/COP
Cap 47
Cap 17
SEER
EER
Heat Pump System 1
SplitHeatPump
4
8.2
32500
19920
15
12.2
Not Zonal
Single Speed
Heat Pump System
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Heat Pump System 1-hers-cool
Required. ItP"' _-
.;350 IM MI
1(121� Requ'ired
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02 A
0 r- or 1
„� A"� 0.4� ��o
�1 ^ �-OS �
06
07
Name
Type `� i
I 1Duct�Leakitge
In"sulation'R-value @
Duct-LocIt on
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
---
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
- HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
Registration Number: 217-P010002453C-000-000-0000000-0000 Registration DatelTime: 2017-06-29 09:14:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-29 08:09:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 24 Residence Calculation Date/Time: 08:07, Thu, Jun 29, 2017
Calculation Description: Title 24 Analysis Input File Name: Plan 24-Andalusia-17.ribdl6x
CF1R-PRF-61
Page 9-of 10
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Waft Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%,)
HERS Verification
SFam IAQVentRpt
72
0.25
Default
0
- Required
'HERSCa i E T�S/ I n c.
PROVIDER
i>Y r D i a ,-�
Registration Number: 217-P010002453C-000-000-0000000-0000 Registration Date/Time: 2017-06-29 09:14:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-29 08:09:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 24 Residence Calculation Date/Time: 08:07; Thu, Jun 29, 2017
Calculation Description: Title 24 Analysis Input File Name:.P_lan 24=Andalusia-17.ribd16x
CF1 R-PRF-61
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Ti•Wi'�ci
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2017-06-29 09:14:27
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design' features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted�tothe enforcement,agencyfor approvalw�iththis.building permit application.
Responsible Designer Name: , r'`
s
1b,
RRees[ponsible Designer Signatutre:
0 in 11 l
Tim Scott l' .
U if 44
Company:
!�
Date Signed:
2017 06 29 09:1�4:277
Scott Design and Title 24, Inc.
Address:
License:
77085 Michigan Drive
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
0
Easy to Verify
at CaICERTS.com
Registration Number: 217-P010002453C-000-000-0000000-0000 Registration DatefTime: 2017-06-29 09:14:27
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-29 08:09:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 25 Residence Calculation Date/Time: 15:18, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis Input File Name: Plan 25-Andalusia-1 7.ribdl 6x
CF1 R-PRF-61 '
Page 1 of 11,
GENERAL INFORMATION
01
Project Name
Plan 25 Residence
02
Calculation Description
Title 24 Analysis
03
Project Location
Coral Mountains
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.2.1 (695)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.1
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft)
4502
15
Number of Zones
1
16
Slab Area (ft)
4502
17
Number of Stories
1
18
Addition Cond. Floor Area
n/a
19
Natural Gas Available
Yes
�20
Addition Slab Area (ft.)
n/a
21
Glazing Percentage (%)
23.6%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance o00�1*
02
n Pi - `@ } F{. !.e'+�.w K..H `atek.
This building incorporates features that require fieltl testing�and/o�wenficationiby-a certified HERS raterjunder the supe vision of a CEC-approved HERS provider:
•`"r9
03
r� �+. ,� t it ra ice+ ! 1i► iiae ! tlt 1f d
This building incorporates one or more Special Features shown below
N " E. lR S PROVIDER
LQZ % -7 O00�
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVE®
FOR CONSTRUCTION
DATE7 �g iIBY
3po
Registration Number: 217-P010002813 0- o- --%gistration Date/Time: 2017-06-29 09:16:18
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-28 15:19:40
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 25 Residence Calculation Date/Time: 15:18, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis Input File Name: Plan 25-Andalusia-17.ribd16x
CF1 R-PRF-61
Page 2 of 11
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement "
Space Heating.
1.82
2.79
-0.97
-53.3%
Space Cooling
79.84
. 70.63
9.21
11.5%
IAQ Ventilation
0.77
0.77
0.00
0.0%
Water Heating
2.92
8.45
-5.53
-189.4%
PV Credit
----
0.00
0.00
---
North Facing Compliance Total
85.35
82.64
2.71
3.2%
Space Heating
1.82
2.77
-0.95
-52.2%
Space Cooling
79.84
67.20
12.64
15.8%
IAQ Ventilation
0.77
0.77
0.00
0.0%
Water Heating
2.92
8.45
-5.53
-189.4%
PV Credit
----
0.00
0.00
----
East Facing Compliance Total
85.35
79.19
6.16
7.2%
Space Heating
1.82
2.72
-0.90
-49.5%
Space Cooling
IAQ Ventilation
�84.
r0``9
, 7�0�12
0,77
nL0
9.72
0.00
12.2%
0.0%
Water Heating
��2"9i28:45Q
-5.53
-189.4%
PV Credit
H
E-- R S P R 0 NO E
D E R
0.00
South Facing Compliance Total
85.35
82.06
3.29
3.9%
Space Heating
1.82
2.91
-1.09
-59.9%
Space Cooling
79.84
66.89
12.95
16.2%
IAQ Ventilation
0.77
0.77
0.00
0.0%
Water Heating
2.92
8.45
-5.53
-189.4%
PV Credit
--
0.00
0.00
---
West Facing Compliance Total
85.35
79.02
6.33
7.4%
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-28 15:19:40
Registration Number: 217-P010002813D-000-000-0000000-0000 Registration Date/Time: 2017-06-29 09:16:18
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 25 Residence Calculation Date/Time: 15:18, Wed, Jun 28, 2017
CF1 R-PRF-01
Page 3 of 11
Calculation Description: Title 24 Analysis
Input File Name: Plan 25-Andalusia-17.ribd16x
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006' International Energy Conservation Code (IECC). A score of zero represents the energy performance of a building
that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6
(such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under
Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV
Final EDR of Proposed Design
North
49.1
47.8
0.0
47.8
East
49.1
46.2
0.0
46.2
. South
49.1
47.6
0.0
47.6
West
- 49.1 'k
46.1
0.0
46.1
❑
Design meets Tier 1 requirement of'15%o or greater code compliance margin (CALGreen A4.203.1.2.1) and Qll verification prerequisite.
❑
Design meets Tier 2 requiremen't'of 3000 or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design ,Designnatiion requirementfor 3=ngleFamily, in climate one CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
photovoltaic (PV) renewable energy generation suffaien�to�achieve a Final Energy Design. Rating (EDR) of4eroRor less. The PV System must be verified.
REQUIRED SPECIAL FEATURES _ , �. rr+
The following are features that must be installed as conditioh\for meetiingltheymodeted energy perLorrmance fo�this computer analysis.
• Cool roof �° .v � � � • • g � r • � � V
• Insulation above roof deck
• Window overhangs and/or fins_
• Pipe insulation, all lines
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing '
Domestic Hot Water System Verifications:
--None--
Registration Number: P17-P010002813D-000-000-0000000-0000 Registration Date/Time: 2017-06-29 09:16:18 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-28 15:19:40
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 25 Residence Calculation Date/Time: 15:18, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis Input File Name: Plan 25-Andalusia-17.ribd16x
CF1 R-PRF-61
Page 4 of 11
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 25 Residence
4502
1 1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
residence
Conditioned
HVAC1
4502
9
DHW Sys 1
OPAQUE SURFACES
01
` 'a 02
03
04
05
06
07
08
Name
r ^Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
N Wall t
residence
R-21 Wall (W.21.2x6.16)
0
Front
1280
210.92
90
E Wall
residence
R421 Wall.(1N.21.2x6A6)� INK,
90
y� Left
920
278.8
90
S Wall
residence ff
14121'Wall (W'21.2x6f1.6P
180
� Back, —
-- 1280
150.416
90
W Wall
, residence
R 21�Wall,(W�21,.2x6!16)�
1 270 R
�RigAf %
,.a 920
448.015
90
Roof
residencesq
R-38• Roof Attic
w
4502
ATTIC
01
02
03
04 -
05
06
07-
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic residence
Attic Roofresidence
Ventilated
3
0.3
0.75
Yes
Yes
Registration Number: 217-P010002813D-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration DatefTime: 2017-06-29 09:16:18
Report Version - CF1 R-05232017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-28 15:19:40
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 25 Residence Calculation Date/Time: 15:18, Wed, Jun 28, 2017
CF1R-PRF-61
Page 5 of 11
Calculation Description: Title 24 Analysis
Input File Name: Plan 25-Andalusia-17.ribd16x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
20 ---- .32.30
Window
N Wall (Front-0)
2.0
2.0
1
4.0
0.32
0.30
Insect Screen (default)
21 ---- .32.30
Window
N Wall (Front-0)
2.0
2.0
1
4.0
0.32
0.30
Insect Screen (default)
22 ---- .32.30
Window
N Wall (Front-0)
5.0
5.5
1
27.5
0.32
0.30
Insect Screen (default)
23 ---- .30.17
Window
N Wall (Front-0)
2.5
5.5
5.564
76.5
0.30
0.17
Insect Screen (default)
9 ---- .30.30
Window
N Wall (Front-0)
2.5
5.5
1.004
13.8
0.30
0.20
Insect Screen (default)
10 ---- .32.30
Window
N Wall (Front-0)
2.5
5.5
1.004
13.8
0.32
0.30
Insect Screen (default)
11 ---- .32.30
Window
N Wall (Front-0)
2.5
5.5
1.004
13.8
0.32
0.30
Insect Screen (default)
30 ---- .32.30
Window
N Wall (Front-0)
1.5
3.0
1
4.5
0.32
0.30
insect Screen (default)
31 ---- .30.17
Window
N Wall (Front-0)
1.5
3.0
1
4.5
0.30
0.17
Insect Screen (default)
31 ---- .30.17 2
Window
N Wall (Front-0)
1.5
3.0
1
4.5
0.30
0.17
Insect Screen (default)
1 ---- .30.17
Window
N Wall (Front-0)
2.0
5.5
1
11.0
0.30
0.17
Insect Screen (default)
2 ---- .30.17
Window
Wall (Fron4-0)�
2 0 r
^5.5
n 1
11.0
0.30
0.17
Insect Screen (default)
3 -- .30.17
Window
1 N Wall (Front t))� �"
^�^� 2.0
�5.5,
1
r 11.0
0.30
0.17
Insect Screen (default)
4 ---- .30.17
Window
'-N=W6lI#r'onf-0')" ' t
U2.0 t
=$/5.91
U D1 U
"�`1'1 U
0.30
0.17
Insect Screen (default)
24 ---- .32.30
Window
E^Wall IF S P
R9.f"
�12.0,
1
�108.0
0.32
0.30
Insect Screen (default)
25 ---- .32.30
Window
E Wall (Left-90)
6.0
8.0
1
48.0
0.32
0.30
Insect Screen (default)
43 ---- .38.35
Window
E Wall (Left-90)
----
----
1
2.4
0.38
0.35
Insect Screen (default)
12 ---- .32.30
Window
E Wall (Left-90)
9.0
8.0
1
72.0
0.32
0.30
Insect Screen (default)
5 ---- .32.30
Window
E Wall (Left-90)
4.0
5.5
1
22.0
0.32
0.30
Insect Screen (default)
6 ---- .30.17
Window
E Wall (Left-90)
---
----
1
2.4
0.30
0.17
Insect Screen (default)
34 ---- .30.17
Window
S Wall (Back-180)
2.0
5.5
1
11.0
0.30
0.17
Insect Screen (default)
35 ---- .30.17
Window
S Wall (Back-180)
1.5
3.0
1
4.5
0.30
0.17
Insect Screen (default)
36 ---- .30.17
Window
S Wall (Back-180)
5.0
5.5
1
27.5
0.30
0.17
Insect Screen (default)
17 ---- .30.17
Window
S Wall (Back-180)
1.5
3.0
1
4.5
0.30
0.17
Insect Screen (default)
16 ---- .30.17
Window
S Wall (Back-180)
2.5
5.5
1.004
13.8
0.30
0.17
Insect Screen (default)
15 ---- .30.17
Window
S Wall (Back-180)
2.5
5.5
1.004
13.8
0.30
0.17
Insect Screen (default)
14 --- .30.17
Window
S Wall (Back-180)
1.5
3.0
3.067
13.8
0.30
0.17
Insect Screen (default)
13 ---- .30.17
Window
S Wall (Back-180)
3.0
5.5
0.273
4.5
0.30
0.17
Insect Screen (default)
19 ---- .30.17
Window
S Wall (Back-180)
3.0
5.5
1
16.5
0.30
0.17
Insect Screen (default)
Registration Number: 217-P010002813D-000-000-0000000-0000 Registration Date/Time: 2017-06-29 09:16:18 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-28 15:19:40
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 25 Residence Calculation Date/Time: 15:18, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis Input File Name: Plan 25-Andalusia-17.ribd16x
CF1 R-PRF-61
Page 6 of 11
18 ---- .30.17
Window
S Wall (Back-180)
3.0
5.5
1
16.5
0.30
0.17
Insect Screen (default)
8 - 38.35
Window
S Wall (Back-180)
3.0
4.0
2
24.0
0.38
0.35
Insect Screen (default)
28 ---- .32.30
Window
W Wall (Right-270)
12.0
8.0
1
96.0
0.32
0.30
Insect Screen (default)
27 ---- .32.30
Window
W Wall (Right-270)
12.0
8.0
1
96.0
0.32
0.30
Insect Screen (default)
29 ---- .32.30
Window
W Wall (Right-270)
17.3
12.0
1.002
208.0
0.32
0.30
Insect Screen (default)
7 ---- .32.30
Window
W Wall (Right-270)
6.0
8.0
1
48.0
0.32
0.30
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door
E Wall
24.0
0.50
Registration Number: 217-P010002813D-000-000-0000000-0000 Registration Date/Time: 2017-06-29 09:16:18 HERS Provider:. CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-28 15:19:40
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 25 Residence Calculation Date/Time: 15:18, Wed, Jun 28, 2017
CF1 R-PRF-61
Page 7 of 11
Calculation Description: Title 24 Analysis
Input File Name: Plan 25-Andalusia-17.ribd16x
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right
Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
20 ---- .32.30
8
0.1
8
8
0
0
0
0
0
0
0
0
0
21 ---- .32.30
8
0.1
8
8
0
0
0
0
0
0
0
0
0
22 ---- .32.30
8
0.1
8
8
0
0
0
0
0
0
0
0
0
23 ---- .30.17
8
0.1
8
8
0
0
0
0
0
0
0
0
0
9---- .30.30
8
0.1
8
8
0
0
0
0
0
0
0
0
0
10 ---- .32.30
8
0.1
8
8
0
0
0
0
0
0
0
0
0
11 ---- .32.30
8
0.1
8
8
0
0
0
0
0
0
0
0
0
30 ---- .32.30
8
0.1
8
8
0
0
0
0
0
0
0
0
0
31 ---- .30.17
8
0.1
8
8
0
0
0
0
0
0
0
0
0
31 ---- .30.17 2
8'
0.1
8
8
0
0
0
0
0
0
0
0
0
1---- .30.17
` 8
0.1
;:=8
n �81
�",�"= 0:?*CZh
0 jr'14
On
0
0
0
0
0
0
2 ---- .30.17
8
*A0.1
8�
11 10
lro- OF �
If 0
oil It
-1) 07-4
0
0
0
0
0
3---- .30.17
8'
�0.1 `
�8
F8�°
col V
V OCbi
oil U
If OVA
0
0
0
0
0
4---- .30.17
8
"'1011
H8 F
R 8g
F0' R
Q V
1 0F)
F 0R
0
0
0
0
0
24 ---- .32.30
10
0.1
10
10
0
0
0
0
0
0
0
0
0
25 ---- .32.30
10
0.1
10
10
0
0
0
0
0
0
0
0
0
12 ---- .32.30
10
0.1
10
10
0
0
0
0
0
0
0
0
0
5---- .32.30
10
0.1
10
10
0
0
0
0
0
0
0
0
0
34 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
35 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
36 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
17 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
16 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
15 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
14 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
13 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
19 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
18 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
Registration Number: 217-Po10002813D-000-000-0000000-0000 Registration Date/Time: 2017-06-29 09:16:18 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 . Report Generated at: 2017-06-28 15:19:40
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 25 Residence Calculation Date/Time: 15:18, Wed, Jun 28, 2017
CF1 R-PRF-61
Page 8 of 11
Calculation Description: Title 24 Analysis
Input File Name: Plan 25-Andalusia-17.ribd16x
8---- .38.35
10 .
0.1
10
10
0
0
0
0
0
0
0
0
28 ---- .32.30
10
0.1'
10
10
0
0
PO
0
0
0
0
0
0
27 ---- .32.30
10
0.1
10
10
0
0
0
0
0
0
0
0
29 ---- .32.30
18
0.1
18
18
0
0
0
0
0
0
0
0
7---- .32.30
10
0.1
10
10
0
0
1 0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
• Cavity / Frame: no insul. / 2x4 Top Chrd
• Roof Deck: Wood Siding/sheathing/decking
2x4 Top Chord of Roof Truss @ 24
Above Deck Insulation: R10 Sheathing
Attic Roofresidence
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.086
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Fram Wall
i
2x6'@�= in! O.0
�►
,� R 21
�0`069
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
SLAB FLOORS -4t� \WJ
U � ;+pus U U `U ft--el ,ff U U V 'ems 0
01
02A H F
R S 03 P R
0 loY ! 1:1
E R 05
06.
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab ex
residence
4502
266
None
0.8
No
BUILDING ENVELOPE -HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
---
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1 (2)
2
.0%
Registration Number: 217-P010002813D-000-000-0000000-0000 Registration Date/Time: 2017-06-29 09:16:18 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-28 15:19:40
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 25 Residence Calculation Date/Time: 15:18, Wed, Jun 28, 2017
CF1 R-PRF-61
Page 9 of 11
Calculation Description: Title 24 Analysis
Input File Name: Plan 25-Andalusia-17.ribd16x
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
Tank
Energy
Tank Insulation
Tank Location or
Heater
Number
Volume
Factor or
Input
R-value
Standby Loss I
Ambient
Name
Element Type
Tank Type
of Units
(gal)
Efficiency
Rating/Pilot
(Int/Ext)
Recovery Eff
NEEA Heat Pump Type
Condition
DHW Heater 1
Gas
Large Storage
2
75
0.76 frac
76,000 Btu/hr
R-0
0.02
/n
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC1
Heat Pump Heating and
Cooling System
Heat Pump System 1
Heat Pump System 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEAT PUMPS
01
02
03
04
05
06
07
08
09
10
11
Name
System
Type
Number of
Units
Heating
Cooling
Zonally
Controlled
Compressor
Type
HERS
Verification
SHSPFIGOF
1Cap 47i►
yKGap17
SEER
EER
Heat Pump System 1
SplitHeat.P+um
.,us4(
8X
'4
�34J250
�-.
2055)1
�
* 1 1.1124p'
Not Zonal
Single Speed
Heat Pump System
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
66
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Heat Pump System 1-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
---
Registration Number: 217-P010002813D-000-000-0000000-0000 Registration Date/Time: 2017-06-29 09:16:18 HERS Provider: CaICERTS inc..
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-05232017-695 Report Generated at: 2017-06-28 15:19:40
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 25 Residence Calculation Date/Time: 15:18, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis Input File Name: Plan 25-Andalusia-17.ribd16x
CF1 R-PRF-01
Page 10 of 11
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
IAQ Recovery
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
r r i 75
0.25
Default
0
Required
ERTS Inc.
i • D y.
Registration Number: 217-P010002813D-000-000-0000000-0000 Registration Date/Time: 2017-06-29 09:16:18
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF 1 R-05232017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-28 15:19:40
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 25 Residence Calculation Date/Time: 15:18, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis Input File Name: Plan 25-Andalusia-17.ribd16x
CF1 R-PRF-61
Page 11 of 11 .
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2017-06-29 09:16:18
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business`and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted tto,the enforcement,agencyjor approval,,with,th s.building peamit application.
Responsible Designer Name:
Responsible D`e`s�i+g�ner Signature:
Tim Scott,
Company:
HERS
Date Signed: 1r
ER
09:1�6:18�
Scott Design and Title 24, Inc.
2017-06 29
Address:
License:
77085 Michigan Drive'
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
❑ ❑
r L:.L.:ih P;
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 217-P010002813D-000-000-0000000-0000 Registration Date/Time: 2017-06-29 09:16:18 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-28 15:19:40
q CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name: Plan 26 Residence Calculation Date/Time: 15:27, Fri, Jun 23, 2017 Page 1 of 11
Calculation Description: Title 24 Analysis Input File Name: Plan 26-Andalusia-17.ribdl6x
la
GENERAL INFORMATION
01
Project Name
Plan 26 Residence
02
Calculation Description
Title 24 Analysis
03
Project Location
Coral Mountains
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.2.1 (695)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.1
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
5131
15
Number of Zones
1
16
Slab Area (12)
4184
17
Number of Stories
1
18
Addition Cond. Floor Area
n/a
19
Natural Gas Available
Yes
r2O
Addition Slab Area (ft2)
n/a
21
Glazing Percentage 1%)
24.4%
COMPLIANCE RESULTS
01
.....
Building Complies with Computer Performance
02
r� rox a=1. s x r- v r..n�
This building incorporates features that require fief i testing and/or,verif, ion by'a certified HERS ratee�u}n�der theme sugpergviision of agCEC-approved HERS provider.
03
. y r'A.:,.:...�. P.:n ii- � .. 4
This building incorporates one -or more$pecial Features sho n below "
«7
'.�
'�CP� 17 - 000 43
CITY T.
OF QUIP PA
BUILDING & SAFETY
PP
FOR CONSTRUCTION
DATE? � I BY
Registration Number: 217-P01 879C-0
CA Building Energy Efficiency Standards - 2016
Registration Date/Time: 2017-06-23 16:40:53
Report Version - CF1 R-05232017-695
JUL 14 20117
CITY OF UN QUINTA
COMMUNITY DEVELOPMENT
VP -
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-23 15:28:28
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
s
Project Name: Plan 26 Residence Calculation Date/Time: 15:27, Fri, Jun 23, 2017
Calculation Description: Title 24 Analysis Input File Name: Plan 26-Andalusia-1 7.ribdl 6x
9
CF1 R-PRF-01
Page 2 of 11
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
2.04
3.18
-1.14
-55.9%
Space Cooling
77.98
65.78
12.20
15.6%
IAQ Ventilation
0.73
0.73
0.00
0.0%
Water Heating
2.56
2.88
-0.32
-12.5%
PV Credit
--
0.00
0.00
--
North Facing Compliance Total
83.31
72.57
10.74
12.9%
Space Heating
2.04
3.29
-1.25
-61.3%
Space Cooling
77.98
64.22
13.76
17.6%
IAQ Ventilation la
E r.
0.73
0.73
0.00
0.0%
Water Heating %?.
2.56
2.88
-0.32
-12.5%
PV Credit a
--
0.00
0.00
--
r �
East Facing Compliance Total .;;
:.: 83.31
71.12
12.19
14.6%
Space Heating 2.04
3.00
-0.96
-47.1%
Space Cooling ,
64 29
77 98� r
°
C
13.69
17.6%
0.0%
IAQ Ventilation
073 .
0 73:
0.00
Water Heating2°56
..
-0.32
-12.5%
it
-0 00
0.00
--
PV C red f.
South Facing Compliance Total
83.31
70.90
12.41
14.9%
Space Heating
2.04
3.14
-1.10
-53.9%
Space Cooling
71.98
64.18
13.80
17.7%
IAQ Ventilation
0.73
0.73
0.00
0.0%
Water Heating
2.56
2.88
-0.32
-12.5%
PV Credit
---
0.00
0.00
--
t{
West Facing Compliance Total
83.31
70.93
12.38
14.9%
Registration Number: 217-P010002879C-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration DateMme: 2017-06-23 16:40:53 HERS Provider: CaiCERTS inc.
Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-23 15:28:28
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Plan 26 Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 15:27, Fri, Jun 23, 2017
1.
Input File Name: Plan 26-Andalusia-1 7.ribdl 6x
j}4
.f
CFI R-PRF-01
Page 3 of 11
ENERGY DESIGN RATING I 1
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC). A score of zero represents the energy performance of a building
that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6
(such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under
Title 24, Part 11 (CALGreen).
f, f
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable I
energy can both be seen
EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV
Final EDR of Proposed Design
North
48.2
43.1
0.0
43.1
East
48.2
42.4
0.0
42.4
South
48.2
42.3
0.0
42.3
West
48.2
42.3
0.0
42.3
❑
Design meets Tier 1 requirement. 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement'of 30% or:greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
Design meets Zero Net Energy (ZNE) Design Designation requirement -for Single m climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
❑
fFaamily
Energy Design'Ratmg less. The PV System must be verified.
photovoltaic (PV) renewable energy generation sufficient toachieve`a'Final (EDR) of zero or
xr
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condrtion,for meetingithe, modeled energy perfor�mance,forjthis. computer analysis.
• Cool roof
• Insulation above roof deck
• Window overhangs and/or fins
• Pipe insulation, all lines
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications: .
• High quality insulation installation (all)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
11 —None—
Registration Number: 217-P010002879C-000-000-0000000-0000 Registration Date/Time: 2017-06-23 16:40:53 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-23 15:28:28
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 26 Residence Calculation Date/Time: 15:27, Fri, Jun 23, 2017
Calculation Description: Title 24 Analysis Input File Name: Plan 26-Andalusia-17.ribdl6x
CF1 R-PRF-01
Page 4 of 11
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 26 Residence
5131
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
residence
Conditioned
HVAC1
5131
9
DHW Sys 1
OPAQUE SURFACES
01
` 02
03
04
05
06
07
08
Name
I -Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft)
Tilt (deg)
N Wall
< residence
R-21 Wall (W21.2x6.16)
0
Front
1360
428.025
90
E Wall
residence..:.,,
,.µ..
R-21 Wall>(W 21:2x6 18)�
y 90
Left
1080
190
90
S Wall
residence
R'21f1Nall (W21y2x616)F
80
BackF AF
1360
147.616
90
W Wall
�` "residence
R j21 Wall;(W 21:.2x6#16)
e 27q
Righ'1
4, 1080
508.5
90
Roof
residence- L..,1
R-3&RoofAttic
SIC
Tlb OC
5131
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic residence
Attic Roofresidence
Ventilated
3
0.3
0.75
Yes
Yes
Registration Number: 217_P010002879C-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
0
Registration Date/Time: 2017-06-23 16:40:53
Report Version - CF1 R-05232017-695
I
(
HERS Provider:
CaICERTS inc.
Report Generated at: 2017-06-23 15:28:28
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: Plan 26 Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 15:27, Fri, Jun 23, 2017
Input File Name: Plan 26-Andalusia-17.ribd16x
Page 5 of 11
FENESTRATION / GLAZING i
1 01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
;
U-factor
SHGC
Exterior Shading
7 ---- .30.17
Window
N Wall (Front-0)
11.0
10.0
1
110.0
0.30
0.17
Insect Screen (default)
17 ---- .30.17
Window
N Wall (Front-0)
11.0
12.0
1
132.0
0.30
0.17
Insect Screen (default)
29 ---- .30.17
Window
N Wall (Front-0)
2.5
5.5
1.004
13.8
0.30
0.17
Insect Screen (default)
30 ---- .30.17
Window
N Wall (Front-0)
2.5
5.5
1.004
13.8
0.30
0.17
Insect Screen (default)
31 -- .30.17
Window
N Wall (Front-0)
2.5
5.5
1.004
13.8
0.30
0.17
Insect Screen (default)
32 ---- .30.17
Window
N Wall (Front-0)
2.5
5.5
1.004
13.8
0.30
0.17
Insect Screen (default)
33 ---- .30.17
Window
N Wall (Front-0)
2.5
5.5
1.004
13.8
0.30
0.17
Insect Screen (default)
34 -- .30.17
Window . ;;
N Wall (Front-0)
1.5
3.0
1
4.5
0.30
0.17
Insect Screen (default)
35 -- .30.17
Window
N Wall (Front-0)
1.5
3.0
1
4.5
0.30
0.17
Insect Screen (default)
36 ---- .30.17
Window:;
N Wall (Front-0)
1.5
3.0
1
4.5
0.30
0.17
Insect Screen (default)
37 ---- .30.17
Window
-.: N Wall (Front-0)
1.5
3.0
1
4.5
0.30
0.17
Insect Screen (default)
39 ---- .30.17
Window
`;M1Nall (Front-Q)
2 0'(
5.5
1.
11.0
0.30
0.17
Insect Screen (default)
40 -- .30.17
Window
N Wall (Front-l)),
2.0_
5.51
11.0
0.30
0.17
Insect Screen (default)
18 --- .30.17
Window
�``N=V11all Front-0'`� ('
( )
3.6-1 t
5:5
` 1
16:5
0.30
0.17
Insect Screen (default)
19 ---- .30.17
Window
N-;Wall (Front 0) S P
6.0°
�8.0
1
°- 48.0
0.30
0.17
Insect Screen (default)
27 ---- .30.17
Window
N Wall (Front-0)
2.5
5.0
1
12.5
0.30
0.17
Insect Screen (default)
41 --- .30.17
Window
E Wall (Left-90)
2.0
5.5
1
11.0
0.30
0.17
Insect Screen (default)
42 ---- .30.17
Window
E Wall (Left-90)
2.0
5.5
1
11.0
0.30
0.17
Insect Screen (default)
13 ---- .30.17
Window
E Wall (Left-90)
6.0
8.0
1
48.0
0.30
0.17
Insect Screen (default)
15 ---- .30.17
Window
E Wall (Left-90)
3.0
8.0
1
24.0
0.30
0.17
Insect Screen (default)
11 ---- .32.30
Window
E Wall (Left-90)
6.0
8.0
1
48.0
0.32
0.30
Insect Screen (default)
16 --- .30.17
Window
E Wall (Left-90)
3.0
8.0
1
24.0
0.30
0.17
Insect Screen (default)
26 ---- .30.17
Window
S Wall (Back-180)
1.5
3.0
1
4.5
0.30
0.17
Insect Screen (default)
25 ---- .30.17
Window
S Wall (Back-180)
2.5
5.5
1.004
13.8
0.30
0.17
Insect Screen (default)
24 --- .30.17
Window
S Wall (Back-180)
2.5
5.5
1.004
13.8
0.30
0.17
Insect Screen (default)
22 --- .30.17
Window
S Wall (Back-180)
1.5
3.0
1
4.5
0.30
0.17
Insect Screen (default)
21 --- .30.17
Window
S Wall (Back-180)
1.5
3.0
1
4.5
0.30
0.17
Insect Screen (default)
6 ---- .30.17
Window
S Wall (Back-180)
1.5
3.0
1
4.5
0.30
0.17
Insect Screen (default)
5 ---- .30.17
Window
S Wall (Back-180)
1.5
3.0
1
4.5
0.30
0.17
Insect Screen (default)
Registration Number: 217-Po10002879C-000-000-0000000-o000 Registration Date/Time: 2017-06-23 16:40:53 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-23 15:28:28
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
I
Project Name: Plan 26 Residence Calculation Date/Time: 15:27, Fri, Jun 23, 2017
Calculation Description: Title 24 Analysis Input File Name: Plan 26-Andalusia-17.ribd16x
a
CFI R-PRF-01
Page 6 of 11
4 ---- .30.17
3 -- .30.17
Window
Window
S Wall (Back-180)
S Wall (Back-180)
1.5
1.5
3.0
3.0
1
1
4.5
4.5
0.30
1 0.30
0.17
0.17
Insect Screen (default)
Insect Screen (default)
2 ---- .30.17
Window
S Wall (Back-180)
3.0
2.0
1
6.0
0.30
0.17
Insect Screen (default)
1 ---- .30.17
Window
S Wall (Back-180)
3.0
26.0
0.077
6.0
0.30
0.17
Insect Screen (default)
43 ---- .32.30
Window
S Wall (Back-180)
9.0
8.0
1
72.0
0.32
0.30
Insect Screen (default)
38 --- .30.17
Window
S Wall (Back-180)
1.5
3.0
1
4.5
0.30
0.17
Insect Screen (default)
8 -- .32.30
Window
W Wall (Right-270)
10.0
10.0
1
100.0
0.32
0.30
Insect Screen (default)
9 --- .32.30
Window
W Wall (Right-270)
22.0
12.0
1
264.0
0.32
0.30
Insect Screen (default)
28 ---- .32.30
Window
W Wall (Right-270)
11.0
12.0
1
132.0
0.32
0.30
Insect Screen (default)
20 ---- .30.17
Window
W Wall (Right-270)
2.5
5.0
1
12.5
0.30
0.17
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name '' i
''r'
Side of Building
krea (ft2)
U-factor
Door :.;_ :,.,
.,:.:. E Wall
) 24.0
0.50
�CL. TS,
Vim . F R S P,. V I DE
n
Registration Number: 217-P010002879C-000-000-0000000-0000 Registration DateTme: 2017-06-23 16:40:53
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-23 15:28:28
k
i
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name: Plan 26 Residence Calculation Date/Time: 15:27, Fri, Jun 23, 2017 Page 7 of 11
t
i Calculation Description: Title 24 Analysis Input File Name: Plan 26-Andalusia-1 7.ribdl 6x
OVERHANGS AND FINS I
I
01
02
03
04
05
06
07
08
09
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Distt-i:j
Depth
Top Up
Dist R
Bot Up
7--- .30.17
10
0.1
10
10
0
0
0
0
0 }
0
0
0
0
17 ---- .30.17
10
0.1
10
10
0
0
0
0
0 f
0
0
0
0
29 --- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
1 0
30 --- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
31 --- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
32 --- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
33 --- .30.17
10 t z
0.1
10
10
0
0
0
0
0
0
0
0
0
34 -- .30.17
10„> -`:;'
0.1
10
10
0
0
0
0
0 }
0
0
0
0
35 -- .30.17
1.Q
0.1
10
10
0
0
0
0
0
0
0
0
0
36 --- .30.17
10
6.1
10 '
10
0
0
0
0
0
0
0
0
0
37 -- .30.17
a >10
0:1
ye*10
101
0
�0'
0
0
0
0
0
0
0
39 --- .30.17
10
0.1
101,0
0 -.
0
0 1
0¢,. ..
0
0
0
0
0
40 -- .30.17
10
:A0.1
] 0
k 10�
'�t0
" 01
' 0
U
0
0
0
0
0
18 --- .30.17
10
''�Q�1
« 10 -
110S
0
Q
0:
0R
0 1
0
0
0
0
19 --- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
27 -- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
41 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
42 -- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
13 ---- .30.17
10
0.1
10
10
0
0
0
0
0 f
0
0
0
0
15 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
11--.32.30
10
0.1
10
10
0
0
0
0
0 r
0
0
0
0
16 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
26 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
25 --- .30.17
10
0.1
10
10
0
0
0
0
0 !
0
0
0
0
24 --- .30.17
10
0.1
10
10
0
0
0
0
0 `
0
0
0
0
22 -- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
21 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
6--- .30.17
10
0.1
10
10
0
0
0
0
0 i
0
0
0
0
t
Registration Number: 217-P010002679C-000-000-0000000-0000 Registration Date/Time: 2017-06-23 16:40:53 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-23 15:28:28
1
_I CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
103;fika:J:1z451
Project Name: Plan 26 Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 15:27, Fri, Jun 23, 2017
Input File Name: Plan 26-Andalusia-17.ribdl6x
Page 8of11
5--.30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
4--.30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
3--- .30.17
10
0.1
10
10
0 f
0
0
0
0 ;
0
0
0
0
2---- .30.17
10
0.1
10
10
0 ;
0
0
0
0
0
0
0
0
1---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
43 ---- .32.30
10
0.1
10
10
0
0
0
0
0 j
0
0
0
0
38 -- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
0
8--- .32.30
10
0.1
10
10
0
0
0
0
0 {
0
0
0
0
9--- .32.30
18
0.1
18
18
0
0
0
0
0
0
0
0
0
28 --- .32.30
18
0.1
18
18
0 A
0
0
0
0 ;
0
0
0
0
20 ---- .30.17
10
0.1
10
10
0
0
0
0
0
0
0
0
1 0
OPAQUE SURFACE CONSTRUCTIONS
01
02 ''
03
04
05
06
1 07
R '
t
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type,W
Framing
R-value
U-value
Assembly Layers
x
Z7
=*P
Y'
• _ Cavity / Frame: no insul. / 2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decking
a�
2z4Jbp Chord of RoofTtuss @ 24
"none
•Above Deck Insulation: R10 Sheathing
Roof Shingle)
Attic Roofresidence
Attic Roofs"
a Wood Framed -Ceiling .
ink'-O.C!
!
i
0:086
Roofing: Light (Asphalt
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
•lCavity / Frame: R-21/2x6
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 0 Coat Stucco
SLAB FLOORS
01 5
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value &`Depth
Carpeted Fraction
Heated
Covered Slab ex
residence
4184
266
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage +
CFM50
Required
Not Required
I
Not Required
--
Registration Number: 217-Po10002879C-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration DatelTime: 1 2017-06-23 16:40:53
Report Version - CF1 R-05232017-695
I
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-23 15:28:28
1
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 26 Residence Calculation Date/Time: 15:27, Fri, Jun 23, 2017
Calculation Description: Title 24 Analysis
Input File Name: Plan 26-Andalusia-17.ribdl6x
CF1 R-PRF-01
Page 9 of 11
WATER HEATING SYSTEMS
01
02
03
04
2 05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1 (1)
1 1
.0%
WATER HEATERS i
01
02
03
04
05
06
07
08
09
10
11
Tank
Energy
Tank Insulation
Tank Location or
Heater
Number
Volume
Factor or
Input
R-value
Standby Loss /
Ambient
Name
Element Type
Tank Type
of Units
(gal)
Efficiency
Rating/Pilot
(Int/Ext)
Recovery Eff
NEEA Heat Pump Type
Condition
DHW Heater 1
Gas
Small Storage
1
75
0.8 EF
60,000 Btu/hr
R-0
n/a
/n
n/a
SPACE CONDITIONING SYSTEMS
01 z:`':
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC1 x
Heat Pump Heating and.
Heat Pump System 1
Heat Pump System 1
HVAC Fan 1
Air Distribution System 1
Cooling System !
.0w - w4%
HVAC - HEAT PUMPS A �t
01
' `' 02�'^a ^a .a..
"" � 3
04' .05 06
f 07
*68 '
�' 09
10
11
Name
System
Type
Numberlof..
Units
r - Heating
Cooling
Zonally
Controlled
Compressor
Type
HERS
Verification
HSPF/COP
Cap 47
Cap 17
SEER
EER
Heat Pump System 1
SplitHeatPump
5
8.5
1
26500
22500
15
12.5
Not Zonal
Single Speed
Heat Pump System
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
j
Verified SEER
Verified Refrigerant
Charge
Heat Pump System 1-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
'Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
k None
Air Distribution System
1-hers-dist
Registration Number: 217-P010002879C-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
I
Registration Date/Time: 2017-06-23 16:40:53
Report Version - CF1 R-05232017-695
1
it
I
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-23 15:28:28
4
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
P
Project Name: Plan 26 Residence Calculation. Date/Time: 15:27, Fri, Jun 23, 2017 , Page 10 of 11
x
Calculation Description: Title 24 Analysis Input File Name: Plan 26-Andalusia-17.ribd16x
I
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-list
Required
5.0
Not Required
Not Required
Not Required
Not Required
--
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM) t
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58 9
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 : s
102
1 03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan s'`
Required
0.58
IAQ (Indoor Air Quality) FANSR
01
, a.02 .::
t 03n 1m A 14 -
04 . ;
05
06
Dwelling UnitY.
t:t
IAQ CFM{
a �.: , ..: `
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery{
; Effectiveness(%)
HERS Verification
SFam IAQVentRpt
81 '` 1-
Defaulf �
0
Required
Registration Number: 217-P010002879C-000-000-0000000-0000 Registration Date/Time: 2017-06-23 16:40:53 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-23 15:28:28
f
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 26 Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 15:27, Fri, Jun 23, 2017
Input File Name: Plan 26-Andalusia-17.ribdl6x
CF1 R-PRF-01
Page 11 of 11
DOCUMENTATION AUTHORIS DECLARATION STATEMENT
,
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2017-06-23 16:40:53 ;
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
n
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSONIS DECLARATION STATEMENT
I certify the following under penalty of per[0ry, under,the laws of the State of California: /
'
1. 1 am eligible under Division 3 of the Business.and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system'design`features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted toahe enforcement agency for approval wdh;his; building permit application.
Responsible Designer Name: c'
k�� aaa
Responsible Designer Signatu"re
Tcxri.�cmZri
Tim Scott t} ~
=:.- � ,
Company: �"°*i;
Date.Signed: s
6:40: 3
Scott Design and Title 24, Inc. `�
9
20 7 06 23
Address:
License:
77085 Michigan Drive
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 217-P010002879C-000-000-0000000-0000 Registration DateMme: 2017-06-23 16:40:53
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-23 15:28:28