Andalusia TR 31681-3 (Plans 21-23; Plan 25 Trellis Option) 2013 Codes Field Revisions - Title 24BUILDING ENERGY ANALYSIS REPORT ,..
t+� `
PROJECT:
Andalusia Plan 21-A ,
Coral Mountains 75' Lots '
La Quinta, CA
Project Designer:
Pekarek-Crandell,ln
31411 Camino Capistr nCITY OF LA (�T
San Juan. Capistrano, CA 2W&DING & SAFETY I `�
949.487.2320 APPR . EPT
OVED
FOR CONS
RUCTION
DATE_
Report Prepared by.
Gangyi Zhou
GNEP,Engineers
4400 ,Campus Drive
Newport Beach, CA 92660
RECEIVED Job Number:
_ >n
MAR 31 2015 . 63276
CITY OF LA QUINTA g
COMMOHM DMLOPMElff Date:
1 /13/2015 '
l
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report: This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards? j
This program developed by EnergySoft, LLC — www.energysoft.com.
Energ Pro 5.1 by Ene Soft User Number. 8165 RunCode: 201.. 01-13�11:39:5i .(D;63276
.. Y
PERFORMANCE CERTIFICATE _Residential Part 1 of 5.
GF-1.R,
Project Name
Andalusia Plan 21-A
Building Type 0 Single Family 0 Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration .
Date
111312015
Project Address
Coral Mountains 75' Lots .. La, Quinta ... ;
California Energy Climate Zone
, CA Climate Zone 1.5
Total Cond. Floor Area
3, 607 .,
Addition
n/a
# of Stories
1
FIELD INSPECTION-ENEACITCHECKLIST
El Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided, per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION—
Construction,, Ty pe :•.. ; :..
Area Special
Cavity :(ft Features see Part of 5 Status..
Wall Wood Framed R-19 3,092 Ext=R-4.0 New
Roof Wood Framed Attic R-30 3,385 Radiant Barrier New
Wall Wood Framed R-13 270 New
FENESTRATION U- Exterior
Orientation Area(ft Factor SHGC. ;0-yprhong Sidefins,, Shades Status ....
Front (N) 181.0 0.300 0.17 none none Bug Screen New
Front (N) 96.0 0.320 0.30 none none Bug Screen New
Right (lM 107.8 0.300 0.17 none none Bug Screen New
Front (N) 19.0 0.300 0.17 none none Bug Screen New
Front (N) 12.5 0.300 0.17 none none Bug Screen New
Left (E) 144.0 0.320 0.30 10.0 none Bug Screen New
Left (E) 30.3 0.320 0.30 none none Bug Screen New
Left (E) 3.1 0.380 . 0.35 none none Bug Screen New
Right (W) 192.0 0.320 0.30 10.0 none Bug Screen New
Left (E) 59.5 0.300 0.17 none none Bug Screen New
Right (IM 27.5 0.300 0.17 none none Bug Screen New
HV_AC SYSTEMS
Ot . Heating Min.. Eff .,.,,Cool 1,ng Min. Eff.., Thermostat .Status:....,
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback New
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback New
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location ;:. :; .. R-Value ....Status . , ..:.
2.5 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0 New
5 T Ducted
Ducted Attic,. Ceiling Ins, vented 8.0 New
3 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0 New
WATER HEATING
Ot . Type Gallons Min. Eff .Distribution,.:, ,•,.:. _,.. Status
2 Small Gas 50
0.58 Kitchen Pipe Ins New
EnergyPro 5.1 by Ene Soft •User Number.• 8165. , '
_ R►inCodeF201'S-I 143T11:39:57 :10; 63216 Page 3 of73
PERFORMANCE. CERTIFICATE Residential.i :.....:. Part 1 of 5 ..
CF-1 R.
Project Name
Andalusia Plan 21 A
Building Type 0 Single Family ❑ Addition AI'one `" ,` '
❑ Multi Family ❑ Existing+ Addition/Alteration
1.111312015
Date
Project Address
Coral Mountains 75' Lots . La ..Quinta ..
California Energy Climate Zone
CA Climate, Zone:.15........
Total Cond. Floor Area
; _ 3, 607
Addition
nla
.....
# of Stories
1
FIELD INSPECTION -PNERGY CHECKLIST '- ,.
El Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of of this form.
0 Yes ❑ No Special Features --If Yes, see Part 2 of 5 of this form.for details.
INSULATION Area Special
Construction ... T, a Cavity .(fi) Features see..Part 2,of, 5
Status._
FENESTRATION U- Exterior
Orientation Area(ft2) .. Factor SHGC, ,Overhan . Sidefins.,....;.Status.
r
HVAC SYSTEMS
Ot . Heating Min. Eff ..'Ppoling Min. Eff.. Thermostat
1 Split Heat Pump 8.50 HSPF Split Heat Pump 17.0 SEER Setback
New
1 Split Heat Pump 8.50 HSPF Split Heat Pump 17.0 SEER Setback
New
HVAC DISTRIBUTION. Duct
Location Heating Cooling Duct Location .. ; v R-Value
Status .
2 T Ducted Ducted Attic, Ceiling.lns, vented 8.0
New
2 T Ducted Ducted Attic, Ceiling Ins, vented 8.0
New
WATER HEATING
Ot . Type Gallons Min... Eff,., ,.Distribution.:... '
Status
EnefqyPro 5.1 by Energ Soft User Number 8165' RunCode: 201"!-13T11:39.67 JD: 632,76
PERFORMANCE CERTIFICATE Residential , ..: Part ofi 5) CF-1 R..
Project Name
Andalusia Plan 21-A
Building Type ® Single Family ❑'Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1/13/2015
SPECIAL FEATURES INSPECTION CHECKLIST '
The enforcement agency should pay special attention to the items specified in this checklist. These. items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agericy—
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special 'ustification and documentation. submitted.,,. ,
Compliance for all orientations is spi?&ified,• see"section'151 '(cf 2 of the Standards and section 7.6:2 of the Residenti4rCom0liance'Mdfib6L
The Roof R-30 Roof Attic includes credit for a Radiant Barrier that. is Continuous meeting eligibility and installation criteria as'specified in Residential
Appendix RA4.2.2.
HERS REQUIRED VERIFICATION -
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-414 form for each of the measures listed, below for final to be iven.
The Cooling System 2.5 T includes credit foia'12.5 EER Condenser: A certified HERS Mter'must'field verify'M6 installation of the correct Condense'
The HVAC System 2.5 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 2.5 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 2.5 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to -verify that duct
leakage meets the specified criteria.
The Cooling System 5 T includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 5 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 5 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airfiow'of the HVAC System.
The HVAC System 5 T incorporates HERS verged Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
The Cooling System 3 T includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation'of the correct Condenser.
The HVAC System 3 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
EnemyPro 5.1 by Ene Soft . User Number. 81fi5... Run.Code: 2015-01=13T11:39:57 " `. `'OD: 63276 _Pa e 5 of�13`
PERFORMANCE „.CERTIFICATE R,-- 'dential._h (Part. 2 of 6" .. CF-1 R.
Project Name
Andalusia Plan 21 A...
Building Type ® Single -Family `� Addiition Alone
❑ Multi Family ❑ Existing+Addition/Alteration
Date "
, 111312015._
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency -
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special iustification, and. documentation.submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form for each.,.of,the measures listed below for final to,.be given..
Compliance credit for quality installation bf insulation has been used. "HERS field verYr7cation'is iequited.
The HVAC System 3 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 3 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
The Cooling System 2 T includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 2 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 wlcfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 2 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure ain7ow of the HVAC System.
The HVAC System 2 T incorporates HERS verified Duct Leakage. HERS field Verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
The Cooling System 2 T includes credit for a 13.0 EER Condenser. A certirted HERS rater must field verify the installation of the correct Condenser.
The HVAC System 2 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
The HVAC System 2 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 2 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
Ene . Soft )-3T1139:57 7f. 2= D66
PERFORMANCE CERTIFICATI,:.,Res den`#P1-,,' ; ; (Part,3 of S) .. CF-1 R
Project Name
Building Type 0 Single Family-` 13 Addition Alone
Date
Andalusia Plan 21 A
❑Multi Family ❑ Existing+ Addition/Alteration
1/13/2015
77, :.. .
ANNUAL ENERGY.USI= SUMMARY.:. , , ,. ;- ; .. "
Standard - .-Fading' .'Margin Facing ""Margin 'Facing- " ' Margin facing.' 'Margin
TDV kBtu/ft2- r North East South west
Space Heating 5.19 5.63 -0.44 4.16 1.03 3.49 1.70 4.83 0.36
Space Cooling 58.46 39.64 18.82 40.61 17.85 43.24 15.22 41.17 17.29
Fans 11.66 10.49 1.17 10.76 0.90 11.41 0.25 10.84 0.82
Domestic Hot Water 10.11 13.24 -3.13 13.24 -3.13 13.24 -3.13 13.24 -3.13
Pumps 0.00 0.00 0.00 0.00 .0.00 0.00 0.00 0.00 0.00
Totals 85.41 69.01 16.41 68.78 16.64 71.37 14.04 70.09 15.33
Percent Better,Than Standard: ,, :.,...,, :•.:..::.., . .19.2 % . ,. 19.5 %, _ 16.4_% 17.9
__ ...._
BUILDING COMPLIES -HERS VER�FICATION$REQLIMED
Fenestration
Building Front Orientation: All Four orientation Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (N) Z501 309
Fuel Available at Site: Natural Gas (E) 786 237
Raised Floor Area: 0 (S) 0 0
Slab on Grade Area: o (K9 948 327
Average Ceiling Height: 12.0 Roof 3,385 0
Fenestration Average U-Factor: 0.31 TOTAL: 873
Average SHGC:.... 0.24 Fenestration/CFA R,atio_: 24.2
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company GMEP Engineers
�- 1/13/2015
Address 4400 Campus Drive Name Gangyi Zhou
City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
.installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Pekarek-Crandell,lnc
Address 31411 Camino Capistrano Name
City/State/Zip San Juan Capistrano, CA 92675 Phone 949.487.2320 Signed License # Date
EnemyPro 5.1 by EnemySoft User Nu ber'6.165 RunCode: '2015.01-13T11:39:57 "' , ID: 63276' Pa ; 7 of 13
e
CERTIFICATE OF COMPLIANCE Residential ; ; :, (Part 4 of 5) CF-1 R
Project Name
Andalusia Plan 21-A "
Building Type m Single Family` Cl Addition"Atone
❑ Multi Family ❑ Existing+Addition/Alteration
77
Date : "" '
1/13/2015.
OPAQUE SURFACE
DETAILS . 4 ,
'Surface
Type
Area
U-
Factor
Insulation' ." " ; '
: Azm
Tilt
: Status
Joint Appendix
4
Location/Comments
Cavi
Exterior
Frame
Interior
Frame
Wall
198
0.057
R-19
4.6
None
0
90.
New ,'
4.3.17A5. `
Master Suite, Master Bath
Wall
161
0.057
R-19
4.0.
None..
270
90
New
4.3.1-A5
Master Suite, Master Bath
Wall
448
0.057.
R-19
4.0
None
0
90
New
4.3.1-A5 '
Master Suite, Master Bath
Roof
750
0.031
R-30 .
0
0 New
4.2.1-A20
Master Suite, Master Bath
Wall
348
0.057
R-19
4.0
None
0
90
New
4.3.1-A5
Great Room, Entry Kitche
Wall
113
0.057
R-19
4..0
None
90
90
New
4.3.1-A5
Great Room, Ent ; Kitche
Wall
129
0.057
R-19
4.0
None
270
90
New
4.3.1-A5
Great Room, Enf ` ,:Kitche
Wall
55
0.057
R-19
4.0 ,
None
0
90
New
4.3.1-A5
Great Room, Entry, Kitche
Roof
1,250
0.031
R-30 .
0
0 New
4.2.1-A20
Great Room, Entry, Kitche
Wall
163
0.057
R-19
4.0
None
01
90
New
4.3.1-A5
Ha111Bath2Bedrrri21Pwdr
Wall
70
0.057
R-19
4.0
None
90
90
New
4.3.1-A5
Ha111Bath21Bedrm2/Pwdr
Wall
204
0.057
R-19
14.0
None
0
90
New
4.3.1-A5
Ha1VBath21Bedrm21Pwdr
Roof
650
0.031
R-30
0
0 New
4.2.1-A20
Ha111Bath21Bedrrn21Pwdr
Wall
197
0.057
R-19
4.0
None
0
90
New
4.3.1-A5
Casita/Bath4
Wall
2181
0.057
R-19
4.0
None
90
90
New
4.3.1-A5
lCasitalBath4 :
Wall
1581
0.057
R-19_...._
4.'0. :
None"..';
;.
270
'90
New. '
4:11-A5
FENESTRATION•.SURFACE
DETAILS....... •.:: r -. :} �. . _:.. :....
ID
Type
Area
U-Factor
'"'SHGC
Aim
Status
Gazing `.T e
Locati0 omments
1
Window
16.5
0.300 1
NFRC
0.17
NFRC
0
New Casement
Master Suite, Master.Bath
2
Window
24.0
0.320
NFRC
0.30
NFRC
0
New. French
Glass Door
Master Suite; Master Bath
3
Window
64.0
0.300
NFRC
0.17
NFRC .
270
New', ' 'Fixed
Glass.:' '.. •:
Master Suite, Master Bath . `
4
Window
16.5
0.300
NFRC
: 0.17
NFRC ':.
;, 0
New Casement
Master Suite Master Bath '
5
Window
4.5
0.300
NFRC
0.17
NFRC
0
New Casement
Master Suite Master Bath ; t.
6
Window
16.5
0.300
NFRC
- 6.17
NFRC
0
New. Casement
_
Master Suite, Master Bath...
7
Window
4.5
0.300
NFRC
0.17
NFRC
.0
New Casement
..
Master Suite Vashqr Bath
8
Window
14.0
0.300
NFRC.
6.17
NFRC ...
0
New Fixed
Glass ::
Great Room, Ent , Kitchen, ,
9
Wndow
5.0
0.300
NFRC
0.17
NFRC
.0
New Fixed
Glass`;'.
Great Room, Entry Kitchen, .
10
Window
12.5
0.300
NFRC
0.17
NFRC
_ 0
New ..: Single
Hung
Great Room, Entry, Kitchen,
11
Window
27.5
0.300
NFRC.
6.17
NFRC...
0
New .Casement
. `.
Great Room, Entry, Kitchen,
12
Window
144.0
0.320
NFRC
'0.30
NFRC
.'.:..90.
New Sliding
Glass Door
Great Room, Entry,'Kitchen; ; '..,
13
Window
30.31
0.320
NFRC
0.30
NFRC, .
% ,,,90
New. I French
Glass Door "
Great Room, Entry, Kitchen,. W.
14
Window,
3.1
0.380
NFRC
0:35
NFRC..,.
90,
New .:, :Rnd
Fixed Glass
Great Room, Entry Kitchen,
15
Window
1 192.01
0.320
NFRC
0.30
NFRC
270
New Sliding
Glass Door
Great Room,, Entry, Kitchen, .
16
Window
1 43.81
0.300
NFRC
' .0.17 1
NFRC
270
New Fixed
Glass
Great Room; Entry, Kitchen;.
(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: _116-B = D,efault_Table. from $tapoards, NFRC r Labeled Value
-
EXTERIOR
SHADING, D. AILS _.. :. .;..: ...
ID
Exterior Shade Type .
SHGC
Window
Ovethan'
Left Fin
Ri fFin':
H t
Wd
Len
H t
LExt '
RExt'
Dist
Len
H t
Dist
Len
'H t
1
Bug Screen
0.76
2
Bug Screen
0.76
y
3
Bug Screen
0.76
;
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
.
12
Bug Screen
0.76
10.0
12.0
10.0
0.1
3.0
3.0
13
Bug Screen
0.76 .
14 _
Bug Screen
0.76
15
Bug Screen
0.76
10.0
16.0
10.0
0.1
3.0
3.0
`
16 JBug
Screen
0.76
EnergyPro 5.1 by Ene Soft ,UserNom6er 8165 ,:Pae 8 of 13
CERTIFICATE dF. COMPLIANCE ;Res den# al„ .. ._(Part 4 of .5)_ F-1 R
Project Name J
Andalusia Plan 21-A
Building Type m Single Family " 3"Addition Alone ''
❑ Multi Family Q Existing+Addition/Alteration
Date '
1./13/201 .
OPAQUE SURFACE
DETAILS_ '
Surface
Type
Area
U-
Factor
Insulation
Azm
Tilt
Status
Joint Appendix
4.
Location/Comments
Cavity
Exterior
Frame
Interior
Frame
Roof
408
0.031
R-30
0
0 New
4.2.1-A20
Casita/Bath4
Wall
310
0.057
R-19
4.0
None
0
90
New
4.3.1-A5
Zone 4
Wall
148
0.057
R-19
4.0
None
90
90
New
4.3.1-A5
Zone 4
Wall
173
0.057
R-19
14.0
None
1
270
90
New
14.3.1-A5
Zone 4
Wall
270
0.102
R-13
0
90
New
14.3.1-A3
Zone 4
Roof
327
0.031
R-30
0
0 New
4.2.1-A20
Zone 4
FENESTRATION
SURFACE,DETAILS.
ID
Type
Area
U-Factor
SHGC
Azm
Status "
Gjaiin • e
Location/Comments '.
17
Window
11.0
0.300
NFRC
0.17
1 NFRC
0
New Casement
Great Room, Entry, Kitchen,
18
Window
72.0
0.320
NFRC
0.30
NFRC.
0
New French
Glass Door
Ha11/Bath2/Bedrm2/Pwdr
19
Window
4.5
0.300
NFRC
0.17
NFRC
0
New Casement
Ha111Bath2/Bedrm21Pwdr •
20
Window
4.5
0.300
NFRC
0.17
NFRC
0
New Casement
Hall/Bath2/Bedim2/Pwdf
21
Window
27.5
0.300
NFRC
0.17
NFRC
1 0
New Casement
Ha1YBath2/Bedrm2/Pwdr
22
Window
11.0
0.300
NFRC
0.17
NFRC
0
New Casement
Ha11/Bath2/Bedrm2/Pwdr
23
Window
4.5
0.300
NFRC
0.17
NFRC
90
New Casement
Casita/Bath4
24
Window
27.5
0.300
NFRC
0.17
NFRC
90
New Casement
Casita/Bath4
25
Window
27.5
0.300
NFRC
0.17
NFRC
270
New Casement
Casita/Bath4
26
Window
4.5
0.300
NFRC
0.17
NFRC
0
New Casement
Zone 4
27
Window
4.5
0.300
NFRC
0.17
NFRC
0
New Casement
Zone 4
28
Window
27.5
0.300
NFRC
0.17
NFRC
0
New Casement
Zone 4
29
Window
27.5
0.300
NFRC
0.17
NFRC
90
New Casement
Zone 4
(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table frgm Standards, NFRC =,Labeled Value
.... ,:. .
EXTERIOR
SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
Overhang
Left Fin
Ri Fit Fin
Hot
Wd
Len
H t
LExt
RExt
Dist
Len
H t
Dist
Len
H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20 lBug
Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
EnergyPro 5.1 by EnergySoft User Number.: B 65 `RunCode: 2615-01= 1r!,1:19:57 . _ ,}D: 03276 . . ' .. Page 9 of 13
CERTIFICATE OF COMPLIANCE:".Res Oehtia.l ... (Part 5 of 5)' CF-1R
Project Name
Andalusia Plan 21 A
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1.1113120.15.
BUILDING ZONE INFORMATION
-
System Name
Zone Name
Floor Area
Volume
Year Built
New
Existinq
Altered
Removed
2.5 T
Master Suite, Master Bath
861
8,696
5 T
Great Room, Entry, Kitchen, Wet
1,361
19;190
3 T
Ha11/8ath21Bedrm2/Pwdr
650
7,150
2 T
Casita, Bath 4
408
4,488
2 T
Bedroom 3, Bath 3
327
3,597
Totals
3,607
0
.0
0
HVAC SYSTEMS
System Name
Qty.
Heating Type
Min. Eff.
Cooling T b"-
Min. Eff.
ThermosW'T '
Status
2.5 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER
Setback
New
5 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER
Setback
New
3 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER
Setback
New
2 T
1
1 Split Heat Pump
8.50 HSPF.
S lit Heat Pump
17.0 SEER
Setback...
New
2 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
17.0 SEER
Setback
New
HVAC DISTRIBUTION
System Name
Heating
Coolin
Duct Location
Duct
R-Value
Ducts
Tested?
Status
2.5 T
Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
0.
New
5 T
Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
0
New
3 T
Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
El
New
2 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
El
New
2 T Ducted
Ducted
Attic, Ceiling Ins, vented _::...
8.01
0 _ , _
New, .
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
2
Small Gas
Kitchen Pipe Ins
40,000
50
0.58
Na
n/a
New
MULTI -FAMILY WATER
HEATING:DETAI'
S. _ � �, .:' . :....
HYDRONIC
'HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
ft
0
0
a —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty.
HP
Plenum
Outside
Buried
EnergyPro 5.1 by EnergySoft User.Number.. 8165 ... '.. RunCode:.2015-01-13T11:39r57 ' iD: 63276 :pa a '1`O of 13. .
MANDATORY MtA8,UAt9 `$` MMARY ;,.Reside. ltlal. : Pa e 1 Of 3 MF-1 R
Project Name
Andalusia Plan .21„A
Date
1/13/2015
NOTE: Low-rise residential buildingsvoiAect to the Standards: must.comply`with all.applicable mandatory measures listed, ,regardless,of
the compliance approach used. More stringent energy measures'listed on the'Certificate ofi;Comliance (CF 1 R OF 1 R=ADD or CF
1 R-ALT Form) shall supersede the items marked with an asterisk (') below: This Mandatory Measures summary shall be incorporated .:
into the permit documents, and the applicable features shall be considered .by all partrtes as minimum coniponent,performance
specifications whether they are shown elsewhere in the documents or m this. summary. Submit all applicable sections of the MF-1 R
Form with plans.. ....:.
Building Envelo _,e Measures -
116 a 1: Doors and windows between_conditioned and unconditionei s aces are. maritJfactured to limit a t leaka 'e:.". ".:: : ,
§116(a)4: Fenestration products(except field -fabricated windows) have a label listmg`fhe certified U Facto"; certified`SolarHeat Gain
Coefficient SHGC , and infiltration. that.meets the re uiremerits' of 10 1 j ., a
117: Exterior doors and windows are weather-stripped; all.'oints..and erietra jons are.'caulked and sealed.. _
118 a : Insulationspecified or. installed me.ets.Standards fo..r Insulatin .Material. Indicate t and.inclWe. on CF-6,R Form:
§118(i): The thermal erhittance and solar refiectance''VA' ues_;ofJhe cool roofing materiat meeffthe requirements'of §118(i) whenlhe -`
installation of a Cool Roof is specified on the CF-;1 R Form:. `:"
*§150 a : Minimum R-19 insulation in wood-frame.ceilin orequivalent tJ-factor..::...:,.
150 b : Loose fill insulation shall conform.with manufacturer's_installed desi n labeled R,Value..:'_
*§150 c : Minimum R-13 insulation in_wood-frame. wall, ore uivalent U factor. 17
*§150 d : Minimum R-13 insulation in raised wood -frame floor or equivalent U-factor.
150 f : Air retarding wrap is tested, labeled, and installed according to ASTM Ell 677 'k 2000 when s ecified on the CF-1 B Form. :
150 : Mandatory Vapor barrier installed. in,:Climate.Zones.1.4 or,16..,
§150(1): Water absorption rate for slab, edge ihsulation material alone without facings is no greater.than 0.36/6water vapor perm'eance
rate is no greater than,2.0 perm/inch and.shaII be . rote from:..h 'sical dama age" UV..I' ht deterioration
Fireplaces, Deco atrve'Gas'Apoliances:and Gas"Lo 'Measures:
150 e 1 A: Masonry or facto -built fire laces. have `a closable metal or lass door cOverin' the entire o enin of the firebox:
§150(e)l B: Masonry or factory -built fireplaces Have a cbmbustion outside air Intake;'Whlch"is afleast six,square inches in area and is
equipped with a with a readily accessible, o erable, and tight -fitting damper and or.a.pombustion=air control device:: _ ,
§150(e)2: Continuous burning pilot ligfits antJ the use'of iridoorairfor cooling a firebox'jacket en that indoor Air is vented to the'
outside of the buildin , are' _rohibitpd..
S ace Conditioning; Water 1Heatin aril . umbin, System Measures.
§110-§113: HVAC'equipir eht','water'heaters; sh6Wi e' ?heads, faucets'and ail other regulated appliances are'ceriif'ied' by file Energy"
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies'rriee.'t the air release '
valve, backflow prevention,pump,isolation valve, and recirculatipn loo connection re uirernents of. 1.13 c 5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooling appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 1 s0 Btu/hr are exempt), and "pool and
spa heaters.
150 h : Heating and/or coo loads are calculated in accordance with ASHRAE,. SMACNA.or ACCA_•
-ling
150 i : Heating systems are equipped with thermostats that meet,_tbe setback,re uirements-of.Section 1.12 c .
§1500)l A: Storage gas water heaters rated with an fnergyFactor no'geea"ter"ihan the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks foe'soldf water=heating §ystem, or other indirect hot water:
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculatingsections of hot water pipes are insulated er Stardards Table 150-g.
Coolin system piping source `'
§1500)2: g y p p g (suction, chilled water or brine lines) and piping insulated between heating source and indirect hot
water tank shall be insulated tO.Table 150-B and E � action 150. A.
§1500)2: Pipe insulation for steam hydronic heating systems or fiot water'systems >1, S psi, Meets the requirements of Standards Table
123-A.
150 ' 3A: Insulation is protected from damage, including that due to sunli fit, moisture,`e ui ment maintenance, and wind...
§1500)3A: Insulation for chilled water piping.and refrigerant suction lines includesa vapor retardant oris-enclosed entirely in
conditioned space.
150 " 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Co . oration. ..
EnergyPro 5.1 byEnergySoft . 'User.fVumber;8165 ,,... :RunCode: 20f5-01-1$T11 39 57 lD 63276 Page 11 pf,13 .
MANDATORY mEA$VR�.SUMMARY Residential Pa a 2. of 3 MF-1 R
Project Name
Date
Andalusia Plan 21 A
111312015
§150(m)1: All air -distribution system ducts and plenums`installed, are seated and insulated,to rrleet the requirements of. CIVIC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a'mirnmum installed level of i;- .,
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape' of other duct Gosure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that'meets the.'regwremenxs of lil `723. ,If mastic or tape is
used to seal openings greater than 1/4 inch, the combination of mastic and either.mesh or t .-'e shall.be used
§150(m)l : Building cavities, support plafforms for'air handlers,'and,plenums. defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air.'Bolldmg`cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in"the cross=sectidnal area `
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes '
unless such tape is used in combination with. mastic and draw bands.
150 m 7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving` conditioned space haveeither`automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.; .
Cellular foam insulation shall be protected as above or painted with a coating that is wafer retardant `and provides shielding from solar
radiation that can cause degradation of .the material..
150 m 10: Flexible ducts cannot. have_ orous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.240071/entilotion and Acceptable indoor, Air*.
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole'Building Ventilation'
required in Section 4 of that Standard..
Pool and Spa Heating System s and Equipneet Measures:
§114(a): Any pool or spa heating systeni`shalI be ce.i,tified to have:`a'thermal efficiency that complies with the.Appliance Efficiency
Regulations; an on -off switch mounted outside of the heater; a permanentweatherproof plate or card with operating" instructions; and
shall not use electric resistance heating or a pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with At least 36" of pipe betweenfiiter And heater; or dedicated suction
and return lines, or built-up connections for future solar heating.
§114 b 2: Outdoor pools ors as that have a heat pump or as heater shall, have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the:pool water, and atirre switch that Mill allow 611 pumps to beset or '
programmed to run only during off-peak electric demand-� eriods.
150 : Residential_ pool,systems or. e. ui ment meet the.pump sizing, flow rate.,, piping, filters,•and valye -requirements of § 150
Residential Lighting Measures;
§150(k)l : High efficacy luminaires ori_ED Ligfit'Engine with Int@gral Heat'Sinkhas'An efficacy that is no"lower'than'the`efficacies
contained in Table 150-C and is not a low efficacy luminaire.as specified b 150(k)2.
150 k 3: The wattage of permanently installed luminaires shall be determined ass ecified b': 136 d
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire.orexhaust fan 'shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain.:a line -voltage socket orline-
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150 k 7: All switching devices and controls.shall meet the requirements of 150 k 7.
§150(k)8: A minimum of 50 percent of the total rated wattage of pe'rmanentlyinstalled lighting'in kitchens shall be high efficacy:
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2or 100 watts for dwelling units larger than 2,500 ftz maybe
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant =
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; .and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by'a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro5.1 by EnergySoft . User Number. 81.¢5 ., _ RunCode 2015-01,1.3T11:39'r5y 1D t?32�6 .. ' ,Page 12 of.13
MANDATORY MEASURES„SUMMAAY Residential ..(age'
'3 648. MF-TR
Project Name
Date
Andalusia Plan 21-A
111312015
150 k 10: Permanently installed luminaires in bathrobms,'attached'arid detached �afa' es laund ` rooms; closets arid.utilit rooms § O Y � 9 9 ., . ry... y.
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchensbath'rooms; `garages, laundry' rooms, .
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of. 119 oi'rz a manual ,
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a.residential site. is not required to comply with § 150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be iisted'for zero clearance insulation contact (IC) by Underwriters .
Laboratories or other nationally recognized testing/rating laboratory;. and have a label that. certifies the lumiunaire is airtight witFi air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between '
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more,. _.
dwelling units, entrances, balconies, and porches,.which are permanently mounted.to a building residential or to:other buildings on.the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires'shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the. motio.n,sensor,,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocoritrol; 6 .'an'.` `
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680. of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no"'
more than five watts of power as dete.rmined.accordin to §130(d).
§150(k)15: Lighting for parking lots and carports with a. total of.for 8 or more 4ehiclespe'r'site shall comply with the.applicatile
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with"the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed,,non'-dwelling spaces of low-rise residential, buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be aflowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements. of 119.
EnergyPro 5.1 by EnefgySof( User Number-. 8165 . , .. RunCode: �015,01-13T11:39 57 D. 63276 .: Page 13 of ,13
BUILDING ENERGY 14ALY.SI REPORT
PROJECT: '
-Andalusia Plan,2113
• Coral Mountains 75' Lots
La Quinta, CA ,
Project Designer:
Pekarek=Crandell, Inc
31411 Camino Capistrano
San Juan. Capistrano, CA 92675
" . 949.487.2320
Report Prepared by:
Gangyi-Zhou
GMEP Engineers
•4400 :Campus Drive
Newport Beach, CA 92660
Job Number:
63276
Date:
1/13/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the Cal'rfomia Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC = www.energysoft.com, `
EnergyPro 5.1 by Energ Soft 'User Number: 8165 RunCode: 201 &0,,f 13T12:24:23 7D:.63276
PERFORMANCE .CERTIFICATE:. Residential Part 1 .of 5 ,
'CF-1 R
Project Name
Andalusia Plan 21B
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+Addition/Alteration
Date
111312015
Project Address
Coral Mountains 75' Lots„ 1.a. Quinta ::
California Energy Climate Zone
CAClimate.Zone 15,...
Total Cond. Floor Area
...3,280 ...
Addition
n/a
# of Stories
1
FIELD INSPECTION ENEROY CHECKLIST
El Yes ❑ No HERS Measures -- If Yes, A CF-413 must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If.Yes, see Part 2.of.5 of this form for details.
INSULATION '
Construction .. Typo
Area Special
Cavity (ft) Features , see,Part 2, of, 5, Status.:..
Wall Wood Framed
R-19 Z911 Ext=R-4.0 New
Roof Wood Framed Attic
R-30 3,101 Radiant Barrier New
FENESTRATION
Orientation. „Area(
U- Exterior
Factor,.,SHGC Qver,han Sidefins .S,hades :.:.....:....:.::......Status
Front (N) 172.0
0.295 0.17 none none Bug Screen New
Front (N) 24.0
0.315 0.30 none none Bug Screen New
Right (Kq 64.0
0.295 0.17 none none Bug Screen New
Front (N) 19.0
0.295 0.17 none none Bug Screen New
Front (N) 12.5
0.295 0.17 none none Bug Screen New
Left (E) 144.0
0.315 0.30 10.0 none Bug Screen New
Left (E) 30.3
0.315 0.30 10.0 none Bug Screen New
Left (E) 8.5
0.295 0.17 none none Bug Screen New
Right (W) 192.0
0.315 0.30 10.0 none Bug Screen New
Right (W) 43.8
0.295 0.17 10.0 none Bug Screen New
Front (N) 72.0
0.315 0.30 none none Bug Screen New
HVAC SYSTEMS
Qty. Heatiing
Min. Eff Cooling Min. Eff :. ;. .....Thermostat -Status
1 Split Heat Pump
8.50 HSPF Split Heat Pump 15.0 SEER Setback New
1 Split Heat Pump
8.50 HSPF Split Heat Pump 15.0 SEER Setback New
1 Split Heat Pump
8.50 HSPF Split Heat Pump 15.0 SEER Setback New
HVAC DISTRIBUTION ' Duct
Location Heating Cooling Duct Location.. R-Value Status ,
2.5 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0 New
5 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0 New
3 T Ducted
Ducted Attic, Ceiling Ins, vented &0 New
WATER HEATING
Qty. Type
Gallons . Min. Eff.. .. Distribution. , Status
2 Small Gas
50 0.58 Kitchen Pipe Ins New
EnergyPro 5.1 by EnergySoft User,Number'8165. ,. RunCode: 2015t01-137'12:24:Y3 . ' . fD:.63276
Page 3 of 13
_. . .. .._... .
PERFORMANCE CERTIFICATE_.Residential Part .1, of 5 ..._.
Project Name
Andalusia Plan 218
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration .
Date
111312015
Project Address
Coral Mountains 75' Lots La Quinta...,..
California Energy Climate Zone
CA. climate Zoe.1.5.
Total Cond. Floor Area
3, 280
Addition
Na ;
# of Stories
1
FIELD INSPECTION ENEROY'CHECKLIST
El Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided.per Part 2 of 5 of this form.
0 Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of. this form.for. details.
INSULATION `. ' Area Special
Construction Type Cavity (ft) Features (see. Part 2,of 5) , .._ _.Status ... ,.
FENESTRATION U- Exterior
Orientation Area. . Factor.. SHOO Overhan Sidefi.ns..,..Slhades......:.: ::. . _ Status
Front (N) 9.0 0:295 0.17 6.0 none Bug Screen New
Right (tN) 59.5 0.295 0.17 none none Bug Screen New
Left (E) 27.5 0.295 0.17 none none Bug Screen New
HVAC SYSTEMS
City. Heating Min. Eff Cooling Min. Eff Thermostat .,,..Status
1 Split Heat Pump 8.50 HSPF Split Heat Pump 17.0 SEER Setback New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location_ ,. ;:s R-Value .. _ Status.
2 T Heat Pump Ducted Ducted Attic, Ceiling Ins, vented 8.0 New
WATER HEATING
Ot . Type Gallons Min.,Eff- : Distribution .:.:.....: : .. Status
EnergyPro 5.1 by Ene SoR -....User Number. 8165,.. ..RunCodi'2015-0143.T1Z:24c23 7D: 6327ti ;
PERFORMANCE CE..RTIFIC -T : Residential ,.,, (Part.2 of 5)- .. CF-1 R.
Project Name
Andalusia Plan 218
Building Type ®Single Family Ol Addition'Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1/13/2015
SPECIAL FEATURES INSPECTION CHECKLIST '
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation,, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special 'ustificatiQn.and ;documentation submitted,._:. ...: ..: .
Compliance for all orientations is spebified, see'sectiorl"151 (6)`2 of the Standards and section '7.6,2 of the Residential Compliance `Manual.
The Roof R-30 Roof Attic includes credit for a Radiant Sariier that is Continuous meeting eligibility and installation criteria as specked in Residential
Appendix RA4.2.2.
HERS REQUIRED VERIFICATION "
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form for each of the measures listed below for final to•.be, iven.,
The Cooling System 2.5 T includes' credit fora 12.5`EER Condenser. A certified HERS rater must field Verify the installabori`ofthe correct Condenser.'
The HVAC System 2.5 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 2.5 T includes credit for verified adequate airflow. A certirted HERS rater must diagnostically measure airflow of the HVAC System:
The HVAC System 2.5 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System 5 T includes credit for a 12.5 EER Condenser. A certified HERS rater must field verity the installation of the correct Condenser.
The HVAC System 5 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 5 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 5 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specked criteria.
The Cooling System 3 T includes credit for a 12.5 EER Condenser. A certified HERS rater must field verity the installation of the correct Condenser.
The HVAC System 3.T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
EnergyPro 5.1 by Ene Soft User Nurnber.•_8165 ' . >. ,RunCode: 2015-01=13T1144,23 .".`•.. ,aD: 63276, . `..':.: ; '.:• _ "., Page 5 of 13
PERFORMANCE CE:RTI,FI.CATE Fiesidenial 2 :of 5) CF-1 R
Project Name
Andalusia Plan 21 B
Building Type ® Single Family 0 Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111312015
SPECIAL FEATURES INSPECTION"CHECKLIST"
The enforcement agency should pay special attention to the items specified in'this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special 'ustification.and documentation submitted..". .
HERS REQUIRED VERIFICATION +
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R.form for each of the measures..listed-below for, final to be iven. ,.
Compliance credit for quality installation of insulation has been -used: -HERS field verification is required
The HVAC System 3 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 3 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
The Cooling System 2 T includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 2 T Heat Pump includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 2 T Heat Pump includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the
HVAC System.
The HVAC System 2 T Heat Pump incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that
duct leakage meets the specked criteria.
EnergyPro 5.1 by EnemySoft User Number.. 8165. . Run Code: PtH5=01-'13Ti2:24 23"' ' 46,63276 Pa e 6 of 13
PERFORMANCE CERTIFICATE:. Residen�al . Pert 3 of 5) CF-1 R .
Project Name
Building Type 0 Single Family ❑ Addition'A1066" ` `
Date - "
Andalusia Plan 21B
❑ Multi Family ❑ Existing+Addition/Alt eration
1/13/2015
ANNUAL ENERGY ,USEt.SUMMARY...:. _
Standard ` -Facing - ~ ` Margin Facing Margin Facing "Margin Facing Margin
TDV kBtu/ft2- r North East South west
Space Heating 4.99 5.34 -0.35 3.98 1.01 3.17 1.83 4.34 0.65
Space Cooling 58.22 40.19 18.03 40.66 17.57 43.59 14.63 41.75 16.48
Fans 11.54 10.48 1.06 10.62 0.92 11.34 0.21 10.84 0.71
Domestic Hot Water 11.12 14.56 -3.44 14.56 -3.44 14.56 -3.44 14.56 -3.44
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Totals 85.88 70.58 15.29 69.82 16.06 72.66 13.22 71.49 14.39
Percent Better h;Rn.Standar,d:,,,, .; ,.:,,r, 17.8•% :.. ;. 18.7 % .,.. .. 15.4 % 16.8
BUILDING COMPLIES - HERS.VERI.F.ICATION.REQUIRED
Fenestration
Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: . 1.00 (N) 2,194 309
Fuel Available at Site: Natural Gas (E) 640 210
Raised Floor Area: 0 (S) 0 0
Slab on Grade Area: 0 (►M 955 359
Average Ceiling Height: 11.9 Roof 3,101 0
Fenestration Average U-Factor: 0.31 TOTAL: 878
Average SHGC:. 0.24 Fenestration/CFA..Ratio: 26.8 % ..
REMARKS
STATEMENT. OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company GMEP Engineers
1/13/2015
Address 4400 Campus Drive Name Gangyi Zhou
City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Pekarek-Crandell,lnc
Address 31411 Camino Capistrano Name
City/State/Zip San Juan Capistrano, CA 92675 Phone 949.487.2320 Signed License # Date
Ene Pro 5.1 by Ene Soft User Number: 6166 RunCode 2615-01-13T12:24:23 ID:.63276 ". P e 7 of 13
' rl
CERTIFICATE OP" OMPLIANCE Residential :.�: Tart,4 of 5 `" CF-1 R_:
Project Name
Andalusia Plan 21B -• .
Building Type. m Single'Family 4[] Addition`Alone`
❑Multi Family.. .Q Existing+ Addition/Alteration',,.
Date '
1/13/2015.
OPAQUE SURFACE,pETAIL$,
r
Surface
Type
Area
U-
Factor
Insulation'
Azm"
Tilt
Status
Joint App'e'ndlx
4
Location/Comments.
Cavity
Exterior
Frame
Interior.
Frarr4
Wall
198
0.057
R-19
4.0
None._
0
90
New
4.3:1-A5
Mastersuite,. Master Bath
Wall
161
0.057
R-19
4.0
None
270
90
New r `
4.3.1-A5
MasterSuite, Master Bath.
Wall
448
0.057
R-19
4.0
None
0
90
New
4.3.1-A5
Master Suite, Master Bath
Roof
6511
0.031
R-30
0
0 New
4.2.1-A20
Master Suite, Master Bath
Wall
348
. 0.057
R-19
4.0
None
.0
90
1 New.
4.3.1-A5
Great Room, Entry, Kitche
Wall
111
0.057
R-19
14.0
None
90
90
New
4.3.1-A5
Great Room, Entry,' Kitche
Wall
129
0.057
R-19
4.0
None
270
90
New
4.3.1-A5 .
Great Room, Entry,,: 1<'tche
Wall
55
0.057
R-19
4.0
None
0
90
New
4.3.1-A5
Great Room, Ent , Kitche
Roof
1,250
0.031
R-30
0
0 New . '
4.2.1-A20
Great Room, Entry, Kitche
Wall
437
0.057
R-19
4.0
None
- 0
90
New
4.3.1-A5
Bedrm3/Bath1Ha1YBathNB
Wall
100
0.057
R-19
4.0
None
90
90
New
4.3.1-A5
Bedrm3/Bath1Ha111BathZ(8
Wall
153
0.057
R-19
4.0
None
270
90
New .
4.3:1-A5
Bedrm31Bath/Hall/Bath2/ -
Wall
204
0.057
R-19
4.0
None
0
90
New
4.3.1-A5
Bedrm31Bath/HalU8ath21B
Roof
820
0.031
R-30
0
0 New
4.2.1-A20
Bedrm3/Bath1Ha111Bath2/8
Wall r
197
0.057
R-19
4.0
None
0
- 90
New.
4.3.1-A5
Casita/Bath4. .
Wall
219
0.057
R-19, -
4..0 ..
None,
. ;; _:- ;
90
.90
New
4.3.1-A5 ..:.
Casita/Bath4
FENESTRATION
SURFACE,
DETAILS
ID
- Type
Area
' U-Factor
SHGC . "
`Azm `
Status
Glazin ° Type'-`
Locafioh omrrienfs
1
Window.
16.5
0.295
NFRC
0.17
NFRC
0
New ....Casement.'-
,,..: ;; ° . -:.
Master. Suite, Master Bath,
2
Window
24.0
0.315
NFRC
0.30
NFRC
0
New French.
Glass. Door.
Master Suite, Master Bath `
3
Window
64.0
0.295
NFRC
0.17
NFRC
270
New Fixed:Glass
Master Suite, Master8ath
4
Window
16.5
0.295
NFRC
0.17
NFRC
0
New Casement
Master Suite, A%laster Bath
5
Window
4.5
0.295
NFRC
0.1.7
NF8'q `.:
0
New Casement
- .. s _
Master Suite, Master. Bath . ,..
6
Window
16.5
0.295 1
NFRC
0.17
NFRC
-= 0
New " ' Casement
:, ,. '
Master. Suite: -Master8ath
7
Window
4.5
0.295
NFRC .
0.17,
NFRC, ;.
`' 0
New '. Casemen't
Master Suite; Alaster Bath
8
Window
14.0
0.295
NFRC '
, 0.17
NFRC
; 0
New :.: Fixed
Glass,
Great,Roorri,• Entry, Kitchen;
9
Window
5.0
0.295
NFRC
-0.17.
NFRC :'.
::
New `..^-` Fixed
Glass'
Great Room, Entry;' Kitchen,:'. ;
10
Window
12.5
0.295
NFRC
0.17
NFRC
0
"New- .` Single.Hung
Great Room, Entry Kitc . en; ;
11
Window
27.5
0.295
NFRC
0.11
NFRC
0
New ' , Casement
.
Great Room, Entry; kitchen,, . ;
12
Window
144.0
0.315
NFRC.
0.30
NFRC
`; 90
New . ' Sliding'Glass',Door
Great Room;.; Entry Kitchen;
13
Window
30.3
0.315
NFRC
0.30
NFRC
90
New,. _ French
Glass Door
Great, Room; Entry, Kitchen;'` .
14
Window
4.5
0.295
NFRC
0.17
NFRC
_90
New Fixed
Glass
Great Room, Entry, Kitchen;
15
JWindow
10.0
0.315
NFRC
0.30
NFRC
270
New Sliding
Glass Door
Great -Room', Entry, 'Kitchen;
16
1 Window
43.8
0.295
NFRC
0.17
NFRC
270.
New Fixed
Glass
Great Room, Entry, Kitchen,
(1) U-Factor Type: .1 16-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: .,116-B =, Default Table. from Standards, NFRC = labeled V.alue......
'
EXTERIOR
SHADING D.E..TAILS
.ID
Exterior Shade T e
SHGC
Window'';'`
' `Overhan
-Left Fin
Right Fin" .
H t
Wd
Len "
H t
LExt
I RExt
Dist
.Len
H t
Dist
Len
H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4 '
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10 :
Bug Screen
0.76
.11
Bug Screen
0.76
12
Bug Screen
0.76
12.0
12.0
10.0
0.1
3.0
3.0
13
Bug Screen
0.76
8.0
4.0
10.0
0.1
3.0
3.0
14
Bug Screen
0.76
,
15
Bug Screen
0.76
12.0
16.0
10.0
0.1
3.0
3.0
16 lBug
Screen
0.761
7.01
6.41
10.01
0.1
3.0
3.0
G
EnergyPro 5.1 by EnergyS6ft `..User Number 8165, ` ,"'RunCode: 2015=01-13tJ1.NJ3 " ' .iD: 6327¢ ' Page 8 of 13
CERTIFICATE OF COMPLIANCE:..Residential .(Part.4. of-5) CF-I.A
Project Name
Andalusia Plan 21 B
Building Type ®Single Family 0Addltio'n Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1/13/2015
OPAQUE SURFACE .D.ETAILS_
. > ..;.
Surface
Type
Area
U-
Factor
Insulation
,Azm.
...Tilt
, Status
Joint Appendix "
4
Location/Comments
Cavit
Exterior
Frame
Interior
Frame'
Wall
153
0.057
R-19
4.0
None
270
90
New
4.3.1-A5
Casita/Bath4
Roof
380
0.031
R-30
0
0 New
4.2.1-A20
Casita/Bath4
FENESTRATION,.SURFACE.DETAIL$
ID
Type
Area
U-Factor
SHGC2
Azm'
'Status
'Glazing`' T e' ` '
" LocatiorilComments . `
17
Window
11.0
0.295
NFRC
0.17
NFRC
0
New Casement
Great Room, Entry, Kitchen,
18
Window
72.0
0.315
NFRC
0.30
NFRC
0
New Sliding
Glass Door_ "
Bedrm3Bath/Hall/Bath2/Bed
19
Window
27.5
0.295
NFRC
0.17
NFRC
0
New Casement
Bedrm3/BaftM 111Bath2/Bed
20
Window
4.5
0.295
NFRC
0.17
NFRC
0
New Casement
Bedrm3/Bath1Ha1Bath21Bed;
21
Window
4.5
0.295
NFRC
0.17
NFRC
0
New
[Casement.
Bedrm3/Bath/Ha0/Bath2/Bed ,
22
Window
27.51
0.295
NFRC 1
0.17
NFRC
270
New Casement
Bedrm31Bath1Ha111Bath21Bedrrr
23
Window
4.5
0.295
NFRC
0.17
NFRC
0
New Casement,
Bedrm31Bath1Ha111Bath21Bedrrr
24
Window
4.5
0.295
NFRC
0. 17
NFRC
-0
New Casement.
Bedrm31Bath1Hp1 ath?JBed ,
25
Window
27.5
0.295
NFRC
0.1.7
NFRC,
0
New Casement.
Bedrm318a1h1Ha111Bath2/Bedr7i
26
Window
11.0
0.295
NFRC
0.17
NFRC
-0
New Casemeni
`
Bedrm3/Bath1HalUBath21Bed
27
Window
27.5
0.295
NFRC
0.17
NFRC
:90
New Casement
Casita/Bath4
28
Window
4.0
0.295
NFRC
0.17
NFRC
90
New Fixed
Glass
Casita/Bath4
29
Window
4.5
0.295
NFRC
0.17
NFRC
270
New Casement
Casita/Bath4
30
Window
27.5
0.295
NFRC
0.17
NFRC
270
New Casement
Casita/Bath4
(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: .116-B =.Default Table from. Standards, NFRC = Labeled Value
..
EXTERIOR
SHADING„DETAILS ..
ID
Exterior Shade Type
SHGC
Window
Overhang
Left Fin
Ri ht Fin
H t
Wd
Len
H t
LExt
REA
Dist
Len
H t
Dist
Len
H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
3.0
1.5
6.0
0.1
6.0
6.0
21
Bug Screen
0.76
3.0
1.5
6.0
0.11
6.0
6.0
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
EnergyPro 5.1 by Ene. SoR User Number 8165 `RunCode:.Z015-01-13T12:24:23 ' :10: 63276. Pa e 9 of 13
CERTIFICATE OF COMPLIANCE.:. Residential ; _ .. Part5 Qf 5) - CF-1 R
Project Name
Andalusia Plan 21 B
Building Type 0 Single Family ❑ Addition Alone''
❑ Multi Family Existing+ Addition/Alteration .
Date
Date 01.5
BUILDING ZONE INFORMATION
System Name
Zone Name
Floor Area
Volume
Year Built
New
Existing
Altered
Removed
2.5 T
Master Suite, Master Bath
750
7,575
5 T
Great Room/Entry/KitcheMWet 8
1,222
17,230
3 T
Bedroom 3, Bath 3, Hall, Bath Z
900.
9,900
2 T Heat Pump
Casita/Bath4
408
4,488
Totals
3,280
0
0
0
HVAC SYSTEMS ..:
System Name
Qty.
Heating T�ypb
Win. Eff.
'Cooling Tylid
Min. Eff.
'fheemostat Type
Status
2.5 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER, Setback
New
5 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER Setback
New
3 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER Setback
New
2 T Heat Pump
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
17.0 SEER Setback•
New
HVAC DISTRIBUTION.,_'. 7777777
System Name
Heating
Cooling
Duct Location
Duct
R-Value
Ducts
Tested?
Status
2.5 T
Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
0
New
5 T
Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
0
New
3 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
ID
New
2 T Heat Pump Ducted
Ducted
Attic, Ceiling Ins, vented 1
8.01
0
New
WATER HEATING
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
2
Small Gas
Kitchen Pipe Ins
40,000
50
0.58
n/a
n/a
New
MULTI -FAMILY WATER..HEATING
DETAILS..
HYDRONIC.,HEATING,SY$TEM
PIPING .,, :.:...
Control
Hot Water Piping Length
ft
_ o
i�
v
a —
System Name
Pipe
Len th
Pipe
Diameter
Insul.
Thick.
Qty.
HP
Plenum
Outside
Buried
EnergyPro, 5.1 by EnergySoft User Number'•8165 ; :';::' it'unCode: 2013-01-0T!.2:24.b ' ... "fD: 63276 Page 16 of 13
MANDATORY, MEASURES`SUMMARY:.,.ResidentlalPa a .1 of 3 MF-1 R .
~
Project Name
Andalusia Plan 21 B
Date
111312015
NOTE: Low-rise'residential buildings subject to the Standards must comply with All.appl* ble mandatory r icasures listed,'regardless of::,
the compliance approach used. More stringent energy measures listed on'the Certificate of Compliance (CF 1 R, CF 1 R ADD, or CF
1 R-ALT Form) shall supersede the items marked. with an asterisk'(`) below_ This Mandatory Measures Summary :Shall be..incorporated
`into the permit documents, and the applicable features shall be considered by all parties as'mmimum coniponent;pertorma'nce '
specifications whether they are'shown elsewhere in'the documents,orin this summary:"Submit all applicable sections'of the MF 1 fi' `
Form with tans. : ,:... G _
Building Envelo a Measures L.
1 16a 1: Doors.and windows.between conditioned and unconditioned,s" aces are manufacturetlao;limit air.teaka `e,.
§116(a)4: Fenestration products (except field -fabricated Wj6dow$) have ii label listing the certified U Factor; certified Solar"Heat Gam
Coefficient SHGC ., and infiltration•.that meets ihs`re`uirements`ofi Mb-111. a):
117: Exterior doors and windows are, weather stri" bed all �`oints and, enetr`ations'are caulked and sealed._
118 a :Insulations ecified or.installed• me %-Standards for Insulatin Material. _indicate t e and.include,'on CF-6R Form
§118(i): The thermal emittance and solarfeflectaride values'of the cool roofing maferi61 meets lhe`fequirernents"of`§118'ij when the a..."
installation of a Cool Roof is specified on the.CF 1'R..Form..4
*§150 a : Minimum R-19. insulation. in wood -frame ceilin ore uivalent.U-factor...,
150 b : Loose fill insulation shall conform with manufacturers installed desi n labeled R-Value
*§150 c •: Minimum R-13 insulation in wood -frame wall: ore uivalent U-factor.
*§150 d : Minimum R-13 insulation in,raised wood -frame floor or e. uivalent lJ-factor ;;:•
150 : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 20t)0 when _ ecified on'the CF4R Form.:
150 : Mandatory Vapor barner.installed,in Climate:Zones.14; or 16.. .::.-.
§150(I): Water absorption rate'for slab edgb. insulation material alone withouffacin' & is no;greater than 0.3%o water vapor.per"meance :• .
rate is no reater,than 2.0 ma/inch and, shall be rotected from" h sical.dama` a arid.IJV.light de erioration'.
Fireplaces, Decorstive`Gas A ' lian`ces and Gas,Lo Measures:'.
150 e 1 A: Masonry or.facto -built fire Aces have`a closeble metal. o.r ' lass door coveriri fhe entire o enin of the frrebox
§150(e)l B: Masonry orfactorybuilt' fire places hai,f combustion outside air intake,' which is atleast six`square inches m;'area and is
equipped with a with a readilyaccessible, . .erable,;and tight -fitting damper and or a pombustion=air control device.`
§150(e)2: Continuous burning pilot lights and the use of indoor air'for cooling a firebox ladket when that iridooe air is vented to the
outside of the -building, are, rohibited.
Space Conditionin Vater:Heatm Wand Plumbing S stem Measures „`'A Y ) y
§110-§113: HVAC equipment; water heaters;"stiowerheads,`faucets and'all other regulated appliances are certified b Mhe�Energy'
Commission.. '
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential "occupancies meet the air release .
valve, backflow prevention, pump isolation valve, and recirculation,loo connection"re uiremeots.of §113 c 5... .
-§115: Continuously burning pilot lights are prohibited for;natural gas: fan type central furnaces household cooking" appliances
(appliances with an electrical supply voltage connection with'pilof lights that'consume less than 150 Btu/hr are exempt), and pool and `
spa heaters. z
150 h : Heating and/or cooling loads are calculated in., accordance. with A-$HRAE,,SMACNA•or..ACCA.
150 i : Heating systems are.equipped,with.thermostats that meet the.setback.r.e_uirements.of Section 1.12_
§1500)1 A: Storage gas water heaters rated with an 'Energy'Factor no greater than the fedetarminirrial. standard are exte'rnalily wrapped
with insulation having an installed.thermal. resistance of R-12 or rester.
§1500)1 B: Unfired storage tanks, such as storage'tanks or'backup tanks for sclarwaterheating `system ,ot other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation wtiere-`t6`intem' I insulation R-value'is indicated on -the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to wat2rheater tank, non -recirculating systems, and entire length of:
recirculating sections of hot water pipes are insulated per Standards Table.160-8. ..'. ;
§1500)2: Cooling system piping (suction, chilled water' orbrine lines);and piping insulated between.heating sou"' a and indirect hot
water tank shall be insulated to Table 15.0$ and Equation 150-A. ": °..:• ..:>
§1500)2: Pipe insulation for steam hydronic'fieating systems`or hot water systems >15 psi,'meets the requireh ents of Standards Table
123-A.
1 503A: Insulation is protected from damage, including that due to. sunlight, moisture, .e ui ment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapoirretardant orris enclosed entirely in `
conditioned space.
150 • 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation..-
EnergyPro 5.1 by EnergySoft User Number. 81,65 RunCode 1015-01-13T12:24:23 ro: 63276 :'
.Page 11 of 13
MANDATORY MEASURES SUMMARY. i-esldenial Pa `e 2 of r3 MF=TR
Project Name
Date
Andalusia Plan 21 B
1,111312015
§150(m)1: All air-distribution'system"ductsand plenumsirisfaffed, are sealed"and insulated to meet the.regui-rements of CIVIC Sections` ;
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are.insulated to a-mirnmum installed level of R- .;
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or ofherduct closure system;ahat meets the,
applicable requirements of UL 181, UL.181 A, or UL 181 B or aerosol sealant that meet§ -the requirements. of UL 723 If mastic or tape is
used to seal openings reater than 1/4,inch, the combination.of mastic and ether mesh or." to a shall beaus' d
§150(m)l : Building cavities, support" platform"s for air handlers 'and plenums;defined or constructed with rrratene ats of rthan sealed,
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms'si hall notbe"compressedlo`cause"reductions in'the cross -sectional area'
of the ducts. _
§150(m)2D: Joints and seams of duct systems and their components sha11" not be :sealed with cloth back'rubber'adhesive ducttapes '
unless such tape is used. in combination with mastic and draw bands: :.
150 m 7: Exhaust fans stems have back draftor automatic dam ers ::.. :.
§150(m)8: Gravity ventilating systems serving conditioned `space'have either aut6hi tic`or read'[''
ily accessible;'manually operated
dam ers.
§150(m)9: Insulation shall be protected from damage, including that due to sun Ijgh1.t, moisture equipment maintenance and wind,
Cellular foam insulation shall be protected as above or painted with,a coating that is water' retardant and provides sfiieiding from"solar '
radiation that can cause d-,gradation of the material.
150 m 10: Flexible ducts cannot have, orous inner cores.
§150(o): All dwelling units shall meet.the r'equirementsof ANSI/ASHRAE Standard�62 2-2007 Ventilation and Acceptable -'Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing tf e'Whole tuilding Ventilation , '
required in Section_4.of that Standard.
Pool and Spa 11eatin _S stems.and E. w meet Measures° �•. " '
§114(a): Any pool or spa heating system'shall'be'certified to'have a.therrna7tefficiency 1h at complies wrth.the Appliance t #ftciency
Regulations; an on -off switch mounted outside of the. heater; a. permanent weatherproof plate or card with operating instructions; and :
shall not use electric resistance -heating or a. ilot.li ht. `
§114(b)l : Any pool or spa heating equipmenf shall be installed with :at least:36 of pipe between filter and heater; or dedicatdd suction
and return lines,'or built-upconnections,for future solar heatin .
114 b 2: Outdoor pools ors as that have a. heat. um -or. as heater shall have a cover....,,__%,,
§114(b)3: Pools shall have directional'infetsthat-adequately`mix the'pool water, and a time switch (fiat wiH'allow all pumps to beset or "
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems ore. ui merit meet thepurnp sizing, flow,rate,. i, in ; filters, and valve re uir'Ments'of. 150 . '
Residential Lighting Measures,;,
§150(k)1: High efficacy luminaires'or'LED Light Enginewith Integral Neat Sink has anefficacy that is no'lower than ttie efficacies
contained in Table 150-C and is not a low efficacy luminaire_as s ecified b. 15Q k 2, _
150 k 3: The wattage of permanently installed luminaires shall be'determfhed ass ecified b 130 d . ..
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output fre =Ey* no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain line -voltage socket or line- ;
a
voltage lamp holder OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall nofcontain a.
medium screw -base socket. -
150 k 6.- Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the. applicable requirements of. 150(k).
150 k 7: All switching devices and controls shall meet the requirements of 1.50. k 7.
§150(k)8: A minimum of 50 percent of the total rated'waffage of permanently instalted lighting irn'kitchensshall be high efficacy:
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ftz may be
exempt from the 50% high efficacy requirement when: all low,efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed ,
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a- ,
manual -on occupant sensor. .
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear footof
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number.• 8165.... RunCode:.201s-01-13r12:=s1p; ,63276* Page 12 of 13
MANDATORY MEASURES. SUMMARY Resldentlal
Project Name
Date
Andalusia Plan 21 B
111312015
§150(k)10: Permanently installed lumin'aires'in bathrooms; attached and detactied'garages;"laundry rooms, closets'and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed lummaires'Igcated inYroorh§ or areas oth: in. kitchens, bathrooms; garages,:lauhdry rooms,
Pee.than
closets, and utility rooms shall be high efficacy luimnaires, 'EXCEPTION 1ermanentlylhstalled.lo. w efficacy luminaires 'shall be
allowed provided they are controlled by either a dimmer switch that;complies with the applicable requirements of;§119, or'by a manual-.
on occupant sensor that complies with the.. applicable requirements of §119 EXCEPTION 2 Lighting m "detached sto"rage buildirg less'.
than 1000 square feet located on a residential site is not re` uire..to cpm' ( Wit . 150 k
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation dontact `(1C) by Underwfiter$ `
Laboratories or other nationally recognized .testing/rating'laboratory;'and haye a label that certifies the lumiunai-te i.s arrt'ight with air'^
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and'be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including°lighting for private patios iO'014-rise residential 'bwldings with 'four or, more
dwelling units, entrances, balconies, and porches, which are permanently mounted to.a residential building or to other iulldirig's:on the .
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficil_acy luminaires shail,be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not; having: an override or bypass switch that disabies.thejmoUon sensor,`
and one of the following controls: a photocontrol not having an' override or bypass switch that disables tt.6'photoo6n66I; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management,
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor ..:,
luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the" .rnitiori.:
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric'Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address'signs'stiall comply with Section 148, OR not contain a screw -base socket, and consume no
more than five watts of power as determined accords to 130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or morevehiclds per site shall comply with the applicable }
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131 134, and 146. .
§150(k)16: Permanently installed lighting in'the enclosed, non dwelling spsces`df low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed,low efficacy iuiiimaires'shall;be:allowed provided
that they are controlled by an occupant sensors certified,to comply with the applicable requirements of § 119.
EnergyPro 5.1 by EnergySoR , User Number. 8165„ RunCode ., 2015-01 13T12 24 23 ' : 3763276 Page 13 of..13 '
r
BUILDING ,ENERGY;ANALYSIS REPORT
PROJECT'
Andalusia Plan 21 C
` Coral Mountains 75' Lots
La Quinta, CA
Project Designer:
Pekarek-Crandell,Inc
31411 Camino Capistrano`
San Juan Capistrano, CA 92675 ,
949:487.2320 ,
Report Prepared by:
Gangyi Zhou-
GMEP Engineers
4400 Campus Drive
Newport Beach, CA 92660 ,
--Job Number:
63276.
Date:
1 /13/2015 `f
The EnergyPro`computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
Ene Pro 5.1 by Energ Soft User Number. 8165 RunCode: 201541-43T11.3919 ^ ;:ID: 63276 .. ..._ . •._ . .
r
User Number: 8165
EnergyPro 5.1 by EnergySoft;
Job Number:
1D: 63276
PERFORMANCECERTIFICATE:.•.Residential . ..Tart 1 6f.5 .
CF-1R
Project Name
Andalusia Plan 21 C
Building Type 0 Single Family 11 Addit'ion'Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111312015
Project Address
Coral Mountains 7.5'Lots La,Quinta.
California Energy Climate Zone
CA Climate,Zone 1.5 ...
Total Cond. Floor Area
3,280 . ..
Addition
n/a
# of Stories
1
FIELD INS PECTION''ENERGY CHECKLST
El Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area' Special
Cavity ft) .,„ .Features see Part 2 of. 5
Status .
Wall Wood Framed R-19 2,917 Ext=R-4.0
New
Roof Wood Framed Attic R-30 3,101 Radiant Barrier
New
FENESTRATION U- Exterior
Orientation. Area(ft) Factor SHGC ..,_.Overhang Sidefins Shades Status
Front (N) 144.5 0.300 0.17 none none Bug Screen
New
Front (N) 24.0 0.320 0.30 none none Bug Screen
New
Right (W) 57.3 0.300 0.17 none none Bug Screen
New
Front (N) 19.0 0.300 0.17 10.0 none Bug Screen
New
Front (N) 12.5 0,300 0.17 10.0 none Bug Screen
New
Front (N) 36.5 0.300 0.17 10.0 none Bug Screen
New
Left (E) 144.0 0.320 0.30 10.0 none Bug Screen
New
Left (E) 30.3 0.320 0.30 none none Bug Screen
New
Left (E) 36.3 0.300 0.17 none none Bug Screen
New
Right (W) 192.0 0.320 0.30 10.0 none Bug Screen
New
Right (W) 43.8 0.300 0.17 10.0 none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff
Cooling Min. Eff ...:; . _ >; Thermostat . .. Status
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER ' Setback;
New
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback
New
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value „„Status
2.5 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
5 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
3 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
WATER HEATING
at . Type Gallons Min. Eff . ; Distributic..n....,_ :., ,.: Status ..
2 Small Gas 50
0.58 Kitchen Pipe Ins New
EnergyPro5.1byEneTySoft Usef.'.Number,' 0165
RunCode:.�015-01-13T11;39:39. -
Pa e 3 of 13
PERFORMANCE. CERTIFICATE. 'Residential A (Part 1 of 5)
U-1 R
Project Name
Andalusia Plan 21C
Building Type 0 Sing 16' Family 1] Addition Alond"
0 Multi Family 13 Existing+ Addition/Alteration
Date;
111312015
Project Address
Coral Mountains 75'Lots La.Quinta_
California Energy Climate Zone I
CA Climate,Zone 15
Total Cond. Floor Area
3,0
Addition
n1a
#of Stories
"'
FIELD INSPECTION -'ENERGY'CHECKLIST
El Yes 0 No HERS Measures If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
El Yes 11 No Special Features If Yes, see Part 2-.of 5.:of:thi's form for details.,,
INSULATION— Area Special
Construction Type Cavity Jft) Features (,5qe,. part. g.
FENESTRATION U_ Exterior.
Orientation Ama(ft) Factor. SHQ!p Qv
.. grlhiang
Status.
Front (N) 72.0 0.320 0.30 none none Bug Screen
New
Right (Kq 55.0 0.300 0.17 none none Bug Screen
New
Left (E) 4.5 0.300 0.17 none none Bug Screen
New
HVAC SYSTEMS
Oty. Heating Min. Eff Cooling Min, Eff
I Split Heat Pump 8.50 HSPF Split Heat Pump 17.0 SEER Setback
New
HVAC DISTRIBUTION Duct
Location Heating QQQI.in Duct .13-Valuq
Status,
2 T Heat Pump Ducted Ducted Attic, Ceiling Ins, vented 8.0
New
WATER HEATING
Oty. Type Gallons Miir1.,.Eff, _:.Piistribpti1oq __$tatus
EnefqyPro 5.1 by Energy$oft :Vie(Nuinber.8165_*..- ,
--P age: 4 of 13
PERFORMANCE -CERTIFICATE `:Residential ..:, _ :_.: Part 2 o#.5) :. CF-IR
Project Name
Andalusia Plan 21 C
Building Type ® Single'Fam'ily ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111312015
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and,documentation.submitted,;..,;,...,..:: y..:.:
Compliance for all orientations is specked, see sec6on'151 (c)'2 bl the Standards and section 7.6.2 of the Residential Compliance Manual.
The Roof R-30 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification .by a certified HERS Rater. The inspector must, receive a
completed. CF-4R..form for each of the measures Listed below for final to be iver .. u
The Cooling System 2.5 T7ncludes*edit for a 12.5 EER Condenser: A ceitified HERS -rater must field verify the installation of the coiriect`Condenser.
The HVAC System 2.5 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 2.5 T includes credit for verified adequate airflow. A certi6ed HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 2.5 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is'required'to verify that' duct
leakage meets the specified criteria.
The Cooling System 5 T includes credit for a 12.5 EER Condenser. A certified HERS rater must field verity the installation of the correct Condenser.
The HVAC System 5 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 5 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 5 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specked criteria.
The Cooling System 3 T includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 3 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
EnergyPro 5.1 by Ene SoR "UserNwri6'eF 8.tti5 : r'Run.Code: 201.4-6-13T11:39:29 :'.iD: 6327t ; . .::Pa e 5 of 13
PERFORMANCE CERTIFICATE. .: .Res�qrt 6 OF-1
idential 'of' R
Project Name
Andalusia Plan .21C
Buildingtype OSingle 'Family O:Additi6n'Alone
0 Multi Family 0 Existing+ Addition/Alteration
bate'
111312015
SPECIAL FEATURES INSPECTION 'CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement..agency.
determines the adequacy of the justification, and may reject a building or design that o'ther'w:ise'com'o'lie*t'bas6d:dhthe 'adeqtja6-Y of
the sDecial iustificatioriand documentation.submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or. verification by a completed.CF certified HERS Rater. The inspqptor.must receive a
JO I b"'
!74R.form for eAQh..of.jhe measures listed below.for final t to., e given.."
Compliance credit for quality In§tallatfoh of ihs616ti6fi'hjs b6bfi used. HERS fieldVerificationighequlrbd.
The HVAC System 3 Tincludes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 3 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
The Cooling System 2 T includes credit for a 13.0 EER Condenser. A certified HERS rates inuit field v6* 1hi?Jnsta11a6on`6f the correct Condenser.
The HVAC System 2 T Heat Pump includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w1clm.
Compliance credit for quality installation of insulation has been used. HERS field verification isrequired.
The HVAC System 2 T Heat Pump includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the
HVAC System.
The HVAC System 2 TTFeat Pump incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that
duct leakage meets the specified criteria.
Erie Pro 5.1 by Ener qySoft User Nuhibei'1"1,65' .
PERFORMANCE CERTIFICATE Residential (-Part $ of 5, CF71 R
...
Project Name
Building Type 0 Single Family 0 Addition Alone
Date
Andalusia Plan 21 C
❑ Multi Family ❑ Existing+ Addition/Alteration
111312015
ANNUAL ENERGY.USE SUMMARY. .
Standard Facing'". -Margin "Faang Margin `Facing -Maigin Facing Margin
TDV kBtu/ft2- r North East South West
Space Heating 5.02 5.36 -0.34 3.98 1.04 3.31 1.71 4.44 0.58
Space Cooling 58.23 40.15 18.08 40.36 17.87 43.33 14.90 40.93 17.29
Fans 11.54 10.47 1.07 10.55 1.00 11.27 0.28 10.64 0.90
Domestic Hot Water 11.12 14.56 -3.44 14.56 -3.44 14.56 -3.44 14.56 -3.44
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Totals 85.91 70.55 15.36 69.45 16.47 72.47 13.44 70.58 15.33
Percent Better Than Standard: 1.7.9,%. 19.2 % .. ; . , , :.,15.6 % .1.7.8 %
BUILDING C0MPLIES,' -.HERS VERIFICATION REQUIRED_ :.; .. .
Fenestration'
Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (N) Z194 309
Fuel Available at Site: Natural Gas (E) 640 215
Raised Floor Area: o (S) 0 0
Slab on Grade Area: 0 (149 955 348
Average Ceiling Height: 11.9 Roof 3,101 0
Fenestration Average U-Factor: 0.31 TOTAL: 872
Average SHGC:.. 0.23 Fenestration/CFA Ratio: 26.6 i.:. .
REMARKS.
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company GMEP Engineers
1/13/2015
Address 4400 Campus Drive Name Gan 9Yi Zhou
City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the spec'ifications,'and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Pekarek-Crandell,lnc
Address 31411 Camino Capistrano Name
City/State/Zip San Juan Capistrano, CA 92675 Phone 949.487.2320 Signed License # Date
EnemyPro 5.1 6y EnemySoft User Number: a165 :'RuhC de 2015-01-13111r39 29 JD: Bj276 :" '. :'Pa e 7 of 13
°
CERTIFICATE
Project Name
Andalusia Plan 2
n y one
0 Multi Family 0,Existing+.�.ddition/Alteiration
Date`
OPAQUE- SURFAIPE
DETAILS
Surface
Type
Area'
I Factor
InsUhition
I Azrn
Tilt
Status
4-
Location/Comments
Cavity
Exterior
Frame
Inte.riorl
Frame
Gr
11
Window
27.5
0.3 ,
NFR
Great PoQfif,86try,
JK
(1) U-Factor Type: 11 6-A Default Table from Stiridd(ds� NFRQ = Labeled Value
EXTERIOR
SHAPING DETAILS
ID
. Exterior Shade Type..
SHQC
Hgt
Wd
Len
Hgt
LExt..
RExt,
.--Dis�t
Len'
'H6t
Dist*
Len
Hgt
1
Bug Screen
0.76
2
Bug Screen
.0.76
3
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
ag
^
a
CERTIFICATE O�F,COMPLIANCE Residential ` _ :(Part.4 6f_5.) "..:: CF-1 R_
Project Name
Andalusia Plan 21 C. .:.
Building Type • ® Single Family Addition Alone"
❑ Multi Family, ❑.Existing+ Addition/Alteration
1/13/2015
OPAQUE SURFACE -DETAILS.
Surface
Type
Area
U-
Factor
Insulation
Azm
Tilt
Status
Joint Appendix, '
4
Location/Comments
Cavity
Exterior
Frame
Interior
Frame
Wall
158
0.057
R-19
4.0
None
270
90
New c
4.3.1-A5
Casita/Bath4
Roof
380
0.031
R-30
0
0 New
4.2.1-A20
Casita/Bath4
c
FENESTRATION
SURFACE
DETAILS
ID
Type
Area
f1 Factor
'SHGC
Azfi
`Status
Glazin' Type-`
.`LocationtComnients
17
Window.
11.0
0.300
NFRC
0.17
NFRC
6
New Casement
GreafRoom,'Entry, Kitchen,'
18
Window
72.0
0.320
NFRC'.
.0.30
NFRC '
°D
New ,` '. Sliding
Glass Door ..
Bedrni3/8ath/Ha111Bath2/8ed '
19
Window
27.5
0.300
NFRC
0.17
NFRC
0
New Casement
": r a.;'
Bedrm3%Bath%Hall/Bath_2/Bed
20
Window
4.5
0.300
NFRC
0.17
NFRC
.0
New Casement.'
;
Bedmi3/Bath/Ha11/Bath21Bed
21
Window
4.5
0.300
NFRC
"" 0.17
NFRC
: 0
New ::Casement
;: `
Bedrm3/Bath/HalNt3ath2/Bed
22,
Window
27.5
0.300
NFRC
0:17
NFRC
270
New Casement
Bedri i3/Bath/Hall/Bath2/Bed
23
Window
4.5
0.300
NFRC
0.17
NFRC.
0
.New ' Casement'.
::
Bedrm3%Batp#I Ol/t3ath2/Bed `.
24
Window
4.5
0.306
NFRC
. - 0.1J
NFRC ..
'0
New. Casement'.
`
8edrm3/Bath/Hall/Bafii2/Bed ,`-
25
Window
27.5
0.300
NFRC
0:17
NFRC .
0:
New `_, : 'Casement'
. ,.
Bedrrri31BaUMj111Bzith21Bedrh
Window
11.0
0.300
NFRC
0:17
NFRC
0
New " ." Casement
Bedrm3/Bath/HalU,,9ath2/Bed, i .
Window
4.5
. 0.300
NFRC `
0.17
NFRC
90
New Casement
Casita%Bath4
Window
10.6
0.300
NFRC
'0.17
NFRC
90
New--.,' ..' Fixed
Glass
Casita/Bath4
M29
Window
10.6
0.300
NFRC
0.17
NFRC
90
New. ".." -Fixed
Glass `. " :`
Casita/Bath4
Window
10.6
0.300
NFRC
0.17
NFRC
:•,90
New . • Fixed
Glass :'
Casita/Bath4
Window
27.5
0.300
NFRC
0.17
NFRC
276
New Casement'
. " "
'Casita/BatM
(1) • U-Factor Type: 116-A = Default Table from Standards,'NFRC = Labeled Value
2 SHGC Type: 116-8.,= Default Table from Standards, NFRC =,Labeled Value
EXTERIOR
SHADING,DETAILS...
ID
•
Exterior Shade Type
SHGC
Window
overhand
F Left Fin
Ri hf Fin'
H t
Wd
Len
H t
LEM
REM
. Dist
Len
H t
Dist
Len
H t .
17
JBug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
_
20
Bug Screen
0.76
3.0
1.5
10.0
0.1
3.0
3.0
21
Bug Screen
0.76
3.0
1.5
10.0
0.1
-3.0
3.0
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
,
31. lBug
Screen
0.76
f
EnergyPro 5.1 by Ene Soft . . USef.Nitmbef'6165 ",.`. 3turiCode:'2015-01=13i11:38:29. "�D: 63276 ., 'Page 9 of 13
CERTIFICATE•OF COMPLIANCE::Residential.::.: (Part 5_.of:5) :... CF-1'R
Project Name
Andalusia Plan 21 C
Building Type m Single Family EI Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1/13/20,15..
BUILDING ZONE INFORMATION.
System Name
Zone Name
Floor Area
Volume
Year Built
New
Existing
Altered
Removed
2.5 T
Master Suite, Master Bath
750
7,575
5 T
Great Room/Entry/KitcheNWet Bi
1,222
17,230
3 T
Bedroom 3, Bath 3, Hall, Bath 2, 1
900
9,900
2 T-Heat Pump
Casita/Bath4
408
4,488
Totals
3,280
_0J
01
0
HVAC SYSTEMS; . ,
System Name
Ot .
I Heatin Type' "
Min. �Eff.
Conlin 'T e
�Min:`Eff.
"Therrriosbi T e. .:.:
Status
2.5 T
1
1 Split Heat Pump
8.50 HSPF
Split Heat Pump
1.5.0 SEER Setback
_ ` '; . '.
New
5 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15,b SEER Setback
., .. ._
New .
3 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER Setback
New
2 T Heat Pump
1
Slit Heat Pump
8.50 HSPF
Split Heat Pum
17.0 SEER. 5eiback
` .. ':.`. ' `.'
New .
HVAC DISTRIBUTION
System Name
Heating
Cooling
Duct Location
Duct
R-Value
Ducts'
Tested?
Status
2.5 T
Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
0
New
5 T
Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
0
New
3 T
Ducted
Ducted .
Attic, Ceiling. Ins, vented
8,01
0
New
2 T Heat Pump Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
0
New
El
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
2
Small Gas
Kitchen Pipe Ins.
40,000
50
0.58
n/a
n/a
New
MULTI -FAMILY WATER.
HEATING
DETAILS.
.; : ; :.
HYDRONIC.
HEATING
SYSTEM.
PIPING .
Control
Hot Water Piping Length
ft
_ o
m
a —
S stem Name
Pipe
Len th
Pipe
Diameter
Insul.
Thick.
Qty.
HP
Plenum
Outside
Buried
EnergyPro 5.1 by Erie Soft User Number.•..8165 RunCode' 2.01$-01-f3T11:39:29 JD; 63278 . , ` Pa e'10o'f 13'.
MANDATORY MEASURES SUMMARY.. ResldentlI` i'a e 1 of 3, MF71 R .
Project Name :
Date
Andalusia Plan 21 C
111312015
r;
NOTE: Low-rise residential building"s'subject to the Standards must comply with all applicable mandatory'measureslisted; regardless of, ,
the compliance approach used. More stringent energy measureslisted on, -the Certificate :of'Cgmpliance °(Cf 1 R CF 1 R ADD or`CF
1 R-ALT Form) shall supersede the items marked with an, asterisk (*) below.'This'Mandatory Measures Summary'shall be`incorporated
into the permit documents, and the applicable features.shall be considered by all parties as"rnrnimum component;performance
specifications whether they are shown elsewhere i:h the documents or in this' summary Submiti all applicable sections of the MF-1 R.,
Form with planS. ,
Building Envelo 'e Measures ;,
116 a 1: Doors and windows between condiUoned..and s are;rnanufactured to 'limit.air leaka''e
unconditioned aces
§116(a)4: Fenestration products (except field-fabnpated Windows) have e'�1abel listing the certrfied lJ factor certified Soiar'Heat Gam
Coefficient SHGC , and infiltration ifiatmeets'th' re_ wrements'_of. 10-1 f 1 a _-
;
117: Exterior doors and windows,are weather stri ' "ed, all hints and enetratio s are. caUlked.and sealed:'
118 a : Insulation s ecified_or installed meets Standards for J_* ati!2g Material . lndicate,t a `a4include'on C�-6A Form.:
§118(i): The thermal eniittance and solar refiectance.'values Of the cool roofing rriatenal meets the req irements of_.61 f8(i) wlien.'tfie
installation of a Cool Roof is s ecified on the';C0:1R'Form , ,.... ' f
*§150 a : Minimum R-19 insulation in wood-frame,ceH.Ing ore bivalent U #actor
,,.
150 b : Loose fill insulation shall conform..with manufacturer`s installed deli n'labeled R-Value
*§150 c : Minimum R-13.insulatiori in wood -frame wall or.6 wvalent.U-factor , _
*§150 d : Minimum R-13 insulation in raised wood -tramp. floor ore bivalent ll-factor.
150 : Air retardin wra is tested, labeled, and installed accordin to ASTM E. - - 2000 when.`s' ecified on the'CF iR Form
150 : Mandatory Vapor barrier.installed in.C.limate.Zgnes,l4,or 16..,.;,..:•.;.
§150(q: Water absorption rafe br 'slab edge insulation material alone without facings is rib T. greaterahan t):3% water vaporpermeance ; ..:
rate is no greater -than 2.0 erm/inch'and shall bepprotected. from''h' sical clarria a and' i -li ht detenorat'ion.
Fire laces, DePoratW6 Gas" .. Trances and Gas Lo§'Measures:
150 e 1 A: Mason or, facto built fire laces have. a closable metal or `lass door: covens' the entire o enm of the firebox
§150(e)1 B: Masonry or factory=built fireplaces have'a combustion. outside ar'mtake' which'is at least six square mches'in.area and �s
.,
equipped with a with a, readil accessible, o erable,`and ti 'ht flttln damper and or`a combustion;air control device,
§150(e)2: Continuous burning pilot lights and the use 0f indoor airfor.cootin'g a firebox jacket when that indoor air is vented to the
outside of.thebuildiri ,are prohibited'.
Space Conditioning; Water Heating and Plumbing S st66$01e6sures
110- 1.13: HVAC e di 'ment, water heaters, show'eeheads, faucets and. all other re`"ulated'a liances.are certified b the Ener „ '
§ § q � �P 9 PP • Y gY:
Commission.
§113(c)5: Water heating recirculation loops spewing niultiple;dwelling Units anti High=Rise residential, occupancies'ineet the aireiease
:.. - _
valve, backflow prevention,pump.isolation valve,.aiid recircuration'Loo conhedtion.re` uirements oi`
§115: Continuously burning pilotaights are prohibited for natufal gas:'fan type central furnaces hoysehold cooking`apphances ;
i
(appliances with an electrical supply vottage'connection With `pilot lights that consume less'than �150 Btulhr are exempt), and pool and
spa heaters.
150 h : Heating and/or cooling loads are calculated,in,acggrdance with A$HRAE,, .SMACNA,or ACCA.,
150 i : Heating systems aree ui ed.with'thermostats.thatmeet the.Setback. r , wreme AS of Section 1`12 c
§1500)1 A: Storage gas water heaters rated with an nergy'Factor no greater than th6 federal minimal standard ,are 'ezterrially wrapped '
with insulation having an installed thermal resistance of:R=1 or reater _ `
§1500)1 B: Unfired storage tanks such as storage tanks or`backuptanksforsolar water healing system; or•other indirect hot water
.
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation'R-value is'indicated bn the exterior of the
tank.
§1500)2: First 5 feet of hot and cold. water pipes closestto water heater tank, non recirculating Systems,.and entire length of `
,,.
recirculatin sections of hot water. i _es ar,'e insulated r Standards Table 150 B
§1500)2: Cooling system piping (suction chilled water or brine lines),and piping insulated b `tweeri.'heating source and; indirect hot
water tank shall be insulated,.to Tabled 156 81nd;E nation 150 A.
§1500)2: Pipe insulation forsteam hydronic heating systems or hot water systems >15 psi, meets'the iequiremen'tsof Standards Table '
123-A.
150 ' 3A: Insulation is protected from dams e., including that due to sunlight, moisture, equipment maintenance, and. wind,.,:..,:._
§1500)3A: Insulation for chilled Water 'piping'and'refrigerant suction lines'Inc►odes a vapor retardant or is enclosed entirely in
conditioned space.
150 ' 4: Solar water -heating systems and/or collectors are.certifiedb the Solar,11a(tirig and Certification Corporation. ..
EnergyPro5.1 by EnergySoft User iVu her 8165 Rund0e 7015-Q1 ',13T11,r34:29 1D: 63276 ; tpage 11 of 13,'..
MANDATORY MEASURES SUI1AIVIA0Y ,Residential v , Pa e 2 of 3 '.:.,MF-1 R
Project Name
Date
Andalusia Plan 21 C
111312015
§150(m)1: All -air -distribution system `ducts and plenums iristailed, are sealed and "rnsulated' ' meet the requirements of CMC.Sections `
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and pienums are insulated to'a minimum installed level of R
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure "system'th .. meets°the" ".'.
applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant, that meets the requirements of UL 7,23 If.mastic or tape is .
used to seal openings reater-.than 1/4 inch, the combination of.mastic and either mesh'or.,ta a shall be.
§150(m)1: Building cavities, 'support platforms for air'tiandlers, and plenums defined or constructed with materta►s other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air Building cavities an supportplafforms may
contain ducts. Ducts installed in cavities and support plaffornis shall not be comp�es. sed to cause reductions in the cross -sectional area,
of the ducts.
§150(m)2D: Joints and seam's,of `iiuct systems and their cpmponenfs shaO trot be sealed with cloth back rubber adhesive tluct tapes'"
unless such tape is used in comtiination_with mastic and draw bands-
150 m 7: Exhaust fan s ste.,ms, have back draft or:autornatic dam ers ,+• .
§150(m)8: Gravity ventilating` systems serving conditioned space have either'automatic or readily -accessible; manually Tperated
dampers.
§150(m)9: Insulation shall be protected from. damage inip"I ng that'due to sunlight,, moisture equipmer�,t maintenance and wind. -.
Cellular foam insulation shall be protected as atiove,or painted with a coating that is water'retardant.and pr'ovides�shiefding irom"sOla' r '
radiation that can cause degradation of the material... ..; ..
150 m 10: Flexible ducts.,cannot have orous.inner ores.
§150(o): All dwelling units shall I.meet'the requirements of ANSI/ASHRAE Standard .62 2 2007 Ventilation and Acceptable Indoo[,Air.
Quality in Low -Rise Residential Buildings. Window o'peiation is not a permissible method of- prbviding'the Whole Building Ventilation
required in Section,4,of that.$tandard,_ '
Pool and $ a Heating s stems°and O "Li 'ment Measures: ..
§114(a): Any pool or spa heating system`'shall be certified to :have a thermal efficiency thaf'complies with;ihe Appliance Efficiency
Regulations; an on -off switch mounted outside of the heater, a permanent 'weatherproofi plate or cattl with operating mst�uctions an
shall not use electric resistance,heatin or a pilot light
ht.. s
§114(b)1: Any pool or spa heating equipment. shall be installed with at least 36 of pipe between filter and -heat r, or dedicated suction
and return lines, or built-u connecfions.for future solarheatin
114 b 2: Outdoor pools ors pas that have .a. heat puTp or•< as heater shall ha cover.
§114(b)3: Pools shall have directi6nal'mlet§1hat adequately mix ttie pool water and a time. switch that will allow atl pumps to'be- set or
programmed to run only dunn off-peak electric demand. eriods .
§150 :Residential pool systems or.e. ui ment meet. the . um sizin ;`flow rate,. `i' m ; filters, and`va1Je re. udements,of 150
Residential Li htin Measures. 1- ''
§150(k)1: High efficacy, luminaire`s`or LED Light Engine with lntegral Heat Sink hos.an efficacy that'is no.lower than the efficacies '
contained in Table 150-C.and is.not a low eff icacy luminaire.as `s.ecified.b 150k 2 . -
150 k 3: The wattage of er'Map htjy installed.luminaires: shall be:determin* 0 ass ecif'ie.,d bj`§ 130 d .
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall `be electronic"and shall have'an output frequency no�less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights,integral,to a pe�rnanently.iristalled luminaire or exhaust:fan shall.contain "
only high efficacy lamps meeting.the minimum efficacies contained i"Table.150 C, and shall not contain aline -voltage socket or-)ine.-
I[ -
voltage lamp holder; OR shall be rated to consume no more than fi'ive watts ofi pow"er`as determined by''§130(d), and shalt not contain a` '
medium screw -base socket.•,
150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 150(k).
150 k 7: All switching devices and controls shall meet the. requirements of. 150.(k)7., ;-
§150(k)8: A minimum of 50 percent of the total rated'wattage:of permanenfly installed lighting 6Xitchehs shall be high efficacy. '
EXCEPTION: Up to 50 watts for dwelling units less than or, equal to.2,500 ftz or 100 watts for dwelling units'larger than 2,50.0 fiz.maybe .
,- .
exempt from the 50% high efficacy requirement when all low efficacy luminaires in the kitchen are'cpntroiled by a manual on occupant
sensor, dimmer, energy management system (FMCS), or a itiulti-scene programmable con to system and*' I permanently mstatled
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are"high efficacy and controlled'by a
manual -on occupant sensor... I
salllghtingthtisinteltocbnetsshalusnmrethn20wofipower.perinear foot of§150(k)9: Permanently intd na
illuminated cabinet. '
' 1
EnergyPro 5.1 by Energy oft . , ;,user Number. 81 �5 - . _ i'RunCode; 2015-01 13T11 39:29 °'fD: 63276 Page 12
MANDATORY MEASURES SUMMARY R,esiden'lal. Pa a 3.of 3 MF-1 R .
Project Name
Date
Andalusia Plan 21 C
111312015
§150(k)10: Permanently installed luminaires inbati roorns,'attadhed and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor..._
§150(k)l 1: Permanently installed luminaires located'in rooms or areas'other than in kitchens; bathrooms; garages,;laundry rooms,:'.
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1.: Permanently installed low efficacy lumiriaires'shall be:.
allowed provided they are controlled by'either a dimmer switch that complies with the appljcable regwremehts.of §119 or, by a manual, ,,,
on occupant sensor that complies with the applicable requirements :of §119,. EXCEPTIQN 2: Lighting m detached storage buFlding'tess
than 1000 s uare feet located_on.a residential site,is not,require d,to co%n l .with_ 150. k 11. Y
§150(k)12: Luminaires recessed into insulated ceilings shall.be Ustec for zero clearance insulation contact(IC) byUnderw" rrters .;
Laboratories or other nationally recognized testing/rating laboratory; antl have a'la6el that certifies the lumiunaire. is airtight with air .
'a'
leakage less then 2.0 CFM at 75 Pascals when tested in accordance'with ASTM E283; and be sealed With gaskefor cauk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing`outdoor lighting, including" lighting for private patios in low rise residential buildings with .four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residenUatbuild. i or to other buildings on the ..
same lot shall be high efficacy. EXCEPTION 1: Permanently instilled outdoor low efficacy luminaires `shall be allowed provided That
they are controlled by a manual on/off switch, a motion sensor'not having an override or bypass switch'that.disables.th'e moUon;sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables thg.photoconteol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical'time.clock ':O an energy, management+"'
control system (EMCS) not having an override or bypass switch that allows the'luniinaire to be always on,' EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the' motion
sensing function provided that the motion sensor is automatically.reactivated within six hours;. EXCEPTION 3. Permanently installed.".. '
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric "Code need not '
be high efficacy luminaires.
§150(k)l4: Internally illuminated address sighs°shall comply with Section '14' 'OR.not contain a screw=base'-kaket, and consume no'
_.,
more than five wafts of power as determined Accordion to' 130 d .
§150(k)l 5: Lighting for parking lots and carports with a to of for 8 or m6fe'vehicles per "site shall eomply'' With the applicable,
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for-8 or.mor646—i4icle§ sA*l comply %44h the applicable
requirements of Sections 130,..131:, 134, and.146.. _
§150(k)l6: Permanently installed lighting in the enclosed non dwelling spaces of low rise'residential buildings Wth_fo4r or'rftore '
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently in$talled'low efficacy luminairesshatl,be allowed provided .
4
that the are controlled b. an occupant sensors certified.to comply with the.a . licable require1
EnergyPro 5.1 by EnergySoft User Num, ber. 8165 RunCode .2015-01 13T11 39�29,.. ; ., :: Tp: 63�76 - � � . Page 13
BUILDING. ENERGY, ANALYSIS REPORT
PROJECT:
Andalusia Plan22A a
Coral Mountains 75' Lots
La Quinta, CA,
Project Designer: ,
t
Pekarek-Crandell,lnc
. T
31411 Camino Capistrano
San Juan Capistrano, CA 92675 r
949.487.2320
Report Prepared, by:
' Gangyi Zhou .
GMEP Engineers ;
*4400 Campus Drive
Newport. Beach, CA 92660
{ CITY OF,LA QUINTA
BUILDING SAFETY DEPT
APPROVED C, N
DATE�
F
ma-ECE
IE Job Number'
63276 ,
MAR 31'.2015 ,
MY of LA QUMTA Date:
COMMUMI'91f DEVELOPMENT
1 /13/2015 ;•
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro, 5.1 by EnergySoft User Number. 8165 :. RunCode: 2615-01-13T11 `53:48
Jy.
PERFORMANCE CERTIFICATE:
'Residential(part ,l.,of 5
CF-1.R .
Project Name
Andalusia Plan 22A
Building Type 0 Single Family'' 11 Addition Along"
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111312015
Project Address
Coral Mountains 75' Lots La Quin.,ta ._ „.
California Energy Climate Zone
CA Climate Zone •15 .,
Total Cond. Floor Area
3,,560
Addition
n/a .
# of Stories
1
FIELD INSPECTION ENERGY.CHECKLIST" `- ` "'`
El Yes ❑ No HERS Measures -- If Yes, A CF-413 must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this .form -for details.,...
INSULATION'
Construction Type
Area Special
Cavity (ft) Features , see Par! 2..of 5 .....
Status
Wall Wood Framed R-19 Z286 Ext=R4.0
New
Roof Wood Framed Attic R-30 3,187 Radiant Barrier
New
FENESTRATION U- Exterior
Orientation Area(ft) Factor ....SHGC . Overhan Sidefins .Shades_..._,., v - . Status_..:_
Front (N) 14.0 0.300 0.20 none none Bug Screen
New
Front (N) 15.0 0.300 0.17 10.0 none Bug Screen
New
Front (N) 37.0 0.300 0.17 10.0 none Bug Screen
New
Left (E) 96.0 0.320 0.30 10.0 none Bug Screen
New
Left (E) 33.8 0.300 0.17 none none Bug Screen
New
Left (E) 30.3 0.320 0.30 10.0 none Bug Screen
New
Left (E) 3.1 0.380 0.35 none none Bug Screen
New
Right (W) 192.0 0.320 0.30 10.0 none Bug Screen
New
Right (W) 64.0 0.320 0.30 none none Bug Screen _
New
Rear (S) 48.0 0.320 0.30 10.0 none Bug Screen
New
Front (N) 16.5 0.300 0.17 6.0 none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff.
Coolling Min. Eff ._..Thermostat . , Status. ,.:,..
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback
New
1 Central Furnace 80% AFUE
Split Air Conditioner 13.0 SEER Setback
New
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location
4 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
2.5 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
3 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
WATER HEATING
Ot . Type Gallons Min. Eff...., ;Distribution .•,; ;., Status.
2 Small Gas 50
0.58 Kitchen Pipe Ins New
EnergyPro 5.1 by EnergySaft User Nymber.-• 8105,
RunCode: 1015-01-13.T11;33:48 ID: 63276
Page 3 of 14
PERFORMANCE CE13TIFICATE:..,R6sidential... :.- `'. Part_ 1 ':ofi.:5
CF-1 R
Project Name
Andalusia Plan 22A
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111312015
Project Address
Coral Mountains 75',Lots La Quinta :..
California Energy Climate Zone
CA. Climate Zone 15...,
Total Cond. Floor Area
3;560 ,:..
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
El Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features,-- If,Yes,.see Part 2 of 5 of this form for details. .
INSULATION Area Special
Construction Type Cavity (ft) Features.fsee Part.2 05..,::.Status
FENESTRATION U- Exterior
Orientation. Area(„ . Factor . ,.SHOP Overhang Sidefins . Shades _.:::,. Status
Right (Kq 96.0 0.320 0.30 8.0 none Bug Screen New
Rear (S) 108.5 0.300 0.17 none none Bug Screen New
Front (N) 48.0 0.320 0.30 10.0 none Bug Screen New
Front (N) 59.5 0.300 0.17 none none Bug Screen New
Right (Kq 11.0 0.300 0.17 10.0 none Bug Screen New
Right (Kq 11.0 0.300 0.17 none none Bug Screen New
Front (N) 11.0 0.300 0.17 8.0 none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff :...Thermostat ,. ;Status.
1 Split Heat Pump 8.50 HSPF Split Heat Pump 17.0 SEER Setback New
HVAC DISTRIBUTION Duct
Location Heating Cool[ing Duct Location......,._..:.. R-Value..... Status
2 T Ducted Ducted Attic, Ceiling Ins, vented 8.0 New
WATER HEATING
Ot . Type Gallons Min. Eff Distribution,. Status
Ene Pro 5.1 b Ene Soh tJserNumber. 8165 ;; .Rui C6de:`20t5-0f-13T1.1c53c4B. ';. , . 1D: 0276..... ;..:...
Page 4 of 14
PERFORMANCE GERTIF.ICATE. ; Resitlential Part2 ofi..5 ) CF-1 R
Project Name
Andalusia Plan 22A
Building Type ® Single' Family Q Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
9/13/2Q15
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the s ecial 'ustification. and documentation submitted...._,
Compliance for all orientations is specified;'sel9.s'ection 151 (c)`2 of the Staridards`and section 7.6.2ofthe''Residential Coinpliance"Manudl.
The Roof R-30 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
.Items in this section require field testing and/or verification by a certified HERS Rater.. The inspector must receive a
completed CF-'4R form .for each of.,ihe rrieasures_listed, below for.final..to be iven.
The Cooling System 3 T includes credit for a'12.5 EER Condenser: 'A certified HERS ratet*nf0st field verify the installation of ttii3 correct Condenser• `-
The HVAC System 4 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 4 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 4 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage '
meets the specified criteria.
The Cooling System 2.5 T includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 2.5 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 2.5 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 2.5 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System 3 T includes credit for a 12.5 EER Condenser. A certified HERS rater must'field verify the installation of the correct Condenser.
The HVAC System 3 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
EnemyPro 5.1 by EnemySoft Wei Number:065 RunCode: 2015=01-13T11 53:48.:: <%D: 63276 ....;; ,: 04tie 5 of 14
PERFORMANCE.CERTIFI-C"' Resideo al..._,:...`:... , (Part 2 :of
Project Name
Andalusia Plan 22A _ ....
Building Type ® Single Family 13 Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111312015
SPECIAL FEATURES INSPECTION •CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation,, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the s ecial iustification.and documentations bT#ted..,.
HERS REQUIRED VERIFICATION -...:..
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form for each. of the measures listed._below for, final to be, iven..,, ,
Compliance credit for quality.in§tallatioii of insulation has been 'W. HERS field •verification is required.
The HVAC System 3 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 3 T incorporates HERS verified. Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
The Cooling System 2 T includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 2 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 2 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 2 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
EnemyPro 5.1 by Ene ySoft User Number: 811i5 "RuriCode: 2015-0'1-13Tll:53:48 � - 10: 63M Page 6 of 14
PERFORMANCE. COMM ' t::..,Residel (Part 3.gf, 5) ., CF-1 R
Project Name
Building Type 0 Single Family ❑ Addition Alone
Date
Andalusia Plan 22A
❑ Multi Family ❑ Existing+ Addition/Alteration
111312015
ANNUAL ENERGY US,E SUMMABy.'_...
Standard 'Facing Margin ' acing ' Margiri Fairing "Margin Facing `` Margin-
TDV kBtu/ft2- r North East South West
Space Heating 4.09 3.76 0.33 4.05 0.04 3.32 0.77 3.37 0.72
Space Cooling 54.46 39.78 14.67 39.12 15.33 39.62 14.84 39.71 14.74
Fans 10.88 9.93 0.95 9.81 1.07 9.95 0.92 9.92 0.96
Domestic Hot Water 10.25 13.23 -2.99 13.23 -2.99 13.23 -2.99 13.23 -2.99
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Totals 79.67 66.70 12.97 66.22 13.45 66.12 13.55 66.24 13.43.
Percent Better Than.Standard: _ 16.3 % 16.9 % 17.0% 16:9
BUILDING COMPLIES ._HERS �iER�FICATION REQUIRED; ..
Fenestratiori'
Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall Area Area .
Number of Dwelling Units: 1.00 (N) 1,120 201
Fuel Available at Site: Natural Gas (E) 360 163
Raised Floor Area: 0 (S) 925 157
Slab on Grade Area: 0 (►M 776 374
Average Ceiling Height: 12.0 Roof 3,187 0
Fenestration Average U-Factor: 0.31 TOTAL: 895
Average SHGC:. ..:: 0.25 Fenestration/C.FA_ Ratio:
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company GMEP Engineers
1/13/2015
4400 Campus Drive Gan i Zhou
me ame 9Y
Na
City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, -and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Pekarek-Crandell,lnc
Address 31411 Camino Capistrano Name
City/State/Zip San Juan Capistrano, CA 92675 Phone 949.487.2320 Signed License # Date
Enem Pro 5.1 by Ene Soft User Number.. 8165 ,: ".;14unCode: 2015-01-13T 1:53:48 tU 63276 Pa e 7 of 14
CERTIFICATE OF COMPLIANCE . , ,Residential :. °(Paq.4 of: 5):... „': IF-1 R
Project Name
Andalusia Plan 22A
Building Type ® Single Family O Addition Alone '
❑ Multi Family ❑ Existing+ Addition/Alteration •
Date
4,/13/2015:
OPAQUE SURFACE•DETAILS
_..,
Surface
Type
Area
U-
Factor
Insulation
Aim
Tilt..',
Status
Joint Appendix
4
Location/Comments. .
Cavity
Exterior
Frame
Interior`
Frame
Wall
399
0.057
R-19
4.0 .
None
0
90
New
4.3.1-A5
Great RooMKitchen/Ent
Wall
157
0.057
R-19
4.0
None
90
' 90
New
4.3.1-A5
Great RoornlKitchenlEntry
Wall
99
0.057
R-19
4.0
None
270
90
New _
4.3.1-A5
Great RoomlKitchenlEntry
Wall
721
0.057
R-19
14.0
None
180
90
1 New
4.3.1-A5
Great RoornlKitchenlEntry
Roof
1,100
0.031
R-30
0
0 New
4.2.1-A20
Great RoonVKitchen/Ent
Wall
84
0.057
R-19
4.0
None
0
90
New
4.3.1-A5
Master Suite/Hall 1
Wall
40
0.057
R-19
-4.0
None
'90
90
New
4.3.1-A5
Master Suite/Hall1 `
Wall
94
0.057
R-19
4.0
None
270
90
New
4.3.1-A5
Master Suite/Hall 1 .
Wall
399
0.057
R-19
4.0
None.
180
90
New
4.3.1-A5
Master Suite/Hall1
Roof
- 950
0.031
R-30
0
0 New
4.2.1 A20
Master Suite/Hall 1 ,.
Wall
245
0.057
R-19
4.0
None
0
90
New
4.3.1-A5
Bed3/Jr Suite/Laundry/Ha
Wall - .
143
. 0.057
R-19 _
4.0
None
270
90
New
4.3.1-A5
Bed3/Jr Suite%Laund /Fia
Wall
298
0.057
R-19
4.0
None
180
90
New
4.3.1-A5
Bed3/Jr Suite/Laundry/Hal
Roof
693
0.031
R-30
0
0 New
4.2.1-A20
Bed3/Jr Suite/Laundry/Hal
Wall
192
0.057
R-1.9
4.0
None
0
90
New
4.3.1-A5
Casita
Wall
66
0.057
R-19 ..
4.0. _
None
1 ;
_ 270,
90
New....
4:3.-1 A5, ' ;: ;, ;- :.
; Casita
FENESTRATION,
SURFACE,
_DETAILS ....... r-
ID
T e
Area
U-Factor
SHGC r
'Azm `
Status
iin GlaType ` `'`''
` Location7Commants
1
Window
4.0
0.300
NFRC
. 0.20
NFRC
0
New. Fixed
Glass
Great Room/Kitchen/Entry/Mo
2
Window
4.0
0.300
NFRC
0.20
NFRC
0
New Fixed
Glass
Great Room/Kitchen/Entry/Mo ,
3
Window
6.0
0.300
NFRC
., 0.20
NFRC
0
New Fixed
Glass ;
Great Roorri/K tchen/EntrylMo
-4 -
Window..
15.0
0.300
NFRC
0.17
NFRC
0
New. Single
Hung - ' .
Great Room/Kitchen/Ent . 1Mo .
5
Window
37.0
0.300
NFRC
0.17
NFRC
0
New FG/MITER,
Great RoomlKitchen/Entry/Mo;
6.
Window
96.0
0.320 1
NFRC
0.30
NFRC
90
New Sliding
Glass Door
Great Room/Kitchen1Entry1Mo,.
7
Window
33.8
0.300
NFRC
0.17
NFRC
90
New FG/MITER
Great RoomJKitchen/Entry/Mo
8
Window
30.3
0.320
NFRC
0.30
NFRC
90
New French'Glass
Door _.
Great Room/Kitchen%Entry/Mo •
9
Window
3.1
0.380
NFRC
0.35
NFRC
90
New Rnd
Fixed
Great Room/Kitchen/En!g ;
10
Window
192.0
0.320
NFRC
0.30
NFRC.
-270
New 'Sliding
Glass Door
Great Room/Kitchen/Entry/Mdi
11
Window
64.0
0.320
NFRC , .
0.30
NFRC
270
New ` Fixed
Glass 0.3210.3 - ,' ..
Great Room/Kitchen1Enlry/Mo,
.12
Window
48.0
0.320
NFRC
0.30
NFRC
180
New Sliding
Glass Door `
Great RoorrMtche' rVEntry/Mo
13
Window
16.5
0.300
NFRC
0.17
NFRC
0
New Casement
Master Suite/Hall 1
14 •
Window
-96.0
0.320
NFRC
0.30
NFRC
270
New Sliding
Glass'Door
Master Suite/Hall 1 �:
15
Window
11.0
0.300
NFRC
0.17
NFRC
180
New Casement
Master Suite/Hall 1
16
Window
11.0
0.300
NFRC
0.17 1
NFRC I
180
New. Casement
Master Suite/Hall 1
(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Tablefrom Standards, NFRC = l,abeled,Value
. .. :..
EXTERIOR
SHADING DETAILS_ _.
ID
_..Exterior Shade Type
SHGC
Window
Overhang,
Left Fin
Right Fin'
H t
Wd
Len
I H t -
LExt
RExt
Dist
Len
H t
Dist
Len
H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
_
4
jBug Screen
0.76
5.0
3.0
10.0
0.1
3.0
-3.0
'
5
Bug Screen
0.76
7.0
5.3
10.0
0.1
3.0
3.0
`
6
Bug Screen
0.76
8.0
12.0
• 10.0
.0.1
3.0
3.0
'
7
Bug Screen
0.76
8
Bug Screen
0.76
8.0
•4.0
10.0
-0.1
3.0
3.0
9
Bug Screen
0.76
,
+•
10
Bug Screen
0.76
10.0
16.0
10.0
0.1
3.0
3.0
11
Bug Screen
0.76
,
12 .
Bug Screen. -
0.76
8.0
6.0
10.0
0.1
3.0
3.0
13
Bug Screen
0.76
5.5
3.0
6.0
0.1
6.0
6.0
14
Bug Screen
0.76
8.0
12.0
8.0
0.1
2.0
2.0
.15
Bug Screen
0.76
16
Bug Screen 1
0.76
EnergyPro 5.1 by Ene Soft ` • -User Number.• :8165 .:.:.•,JQunCode:.2015-01-13T1,1:33:48 _ `" 7D: 63M.' :- Page 8 of 14
CERTIFICATE'O_F COMP.L1Af CE; Aesident al (Part 4.of 5) CF-1 R
Project Name
Andalusia Plan 22A
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1/13/'2015
OPAQUE SURFACE
DETAILS._
Surface
Type
Area
U-
Factor.
Insulation .
Az
Tilt
Status
Joint Appendix
4
Location/Comments
Cavity.Cavity.1
Exterior
Frame.
Interior
Frame
Roof
444
0.031
R-30
0
0 New
4.2.1-A20
Casita
FENESTRATION_SURFACE-DETAILS
ID
Type
Area I
U=Factor
SHGC
Azm
Status"
Glazin d T ..
Locati6n7Comments
17
Window
16.5
0.300
NFRC
0.17
NFRC
180
New Casement
Master Suite/Hall 1
18
Window
16.5
0.300
NFRC
0.17
NFRC
180
New Casement
Master Suite/Hall 1
19
Window
16.5
0.300
NFRC
0.17
NFRC
180
New Casement
Master Suite/Hall 1 _
20
Window
10.0
0.300
NFRC
0.17
NFRC
180
New Casement
Master Suite/Hall 1
21
Window
48.0
0.320
NFRC
0.30
NFRC
0
New Sliding
Glass Door
Bed3/Jr Suitekaundry/Hall 2
22
Window
27.51
0.300
NFRC
0.17
NFRC
0
New Casement
Bed3/Jr Suitekaundry/Hall 2
23
1 Window
4.5
0.300
NFRC
0.17
NFRC
0
New Casement..
Bed3/Jr Suitekaundry/Hall 2
24
Window
11.0
0.300
NFRC
0.17
NFRC
270
New Casement
Bed3/Jr SuitekaundrylHall 2
25
Window
11.0
0.300
NFRC
0.17
NFRC
270
New Casement
Bed3/Jr Suitekaundry/Hall 2
26
Window
4.5
0.300
NFRC
0.17
NFRC
180
New. Casement
Bed3/Jr Suite/Laundry/Hall 2
27
Window
4.5
0.300
NFRC
0.17
NFRC
180
New Casement
Bed3/Jr Suite/Laundry/Hall 2
28
Window
4.5
0.300
NFRC
0.17
NFRC
180
New Casement
Bed3/Jr Suite/Laundry/Hall 2
29
Wndow
4.5
0.300
NFRC
0.17
NFRC
180
New Casement
Bed3/Jr Suitekaundry/Hall 2, ,
30
Window
4.5
0,300
NFRC
0.17
NFRC
180
New Casement
Bed3/Jr Suite/Laundry/Hall 2
31
Window
4.5
0.300
NFRC
0.17
NFRC
180
New Casement
1
Bed3/Jr Suitekaundry/Hall 2 .
32
Window
11.0
0.300
NFRC
0.17
NFRC
0
New Casement
Casita
(1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC.Type: _116-B = Default.Table from.Standards, NFRC = labeled Value
EXTERIOR
SHADING DETAILS '
ID
Exterior Shade Type
SHGC
Window
Ove hang
Left Fin
Right Fin
H t I
Wd
Len
H t
LExt
RExt
Dist
Len
H t
Dist
Len
H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
8.0
6.0
10.01
0.1
3.01
3.0
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
5.5
2.0
10.0
0.1
3.0
3.0
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
31
Bug Screen
0.76
32
Bug Screen
0.76
5.5
2.0
8.0
0.1
2.0
2.0
EnergyPro 5.1 by Ene, ..ff...o14_ 7
• • ' - • - •
Project Name
22A
Building Type ;. Single Family ■ Addition
0 Multi Family 0 Existing+ Addition/Alteration
OPAQUEPlan
..
JointA4 endix
Location/Comments
moo-=
Location/Comments
. W.
il ...
Exterior Shade Type
CERTIFICATE OF'COMPLIANCE:; .Residential (Part 5 yof.5) CF-1 R
Project Name
Andalusia Plan 22A
Building Type ❑ Singie'Fam"ily ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1111312015
BUILDING ZONE INFO
'AT
System Name
Zone Name
Floor Area
Volume
Year Built
New
Existinq
Altered
Removed
4 T
Great Room, Entry, Kitchen, Wet
1,273
17,949
2.5 T
Master Suite, Master Bath
1,150
I Z 650
3 T
Bed3, Jr Suite. Laundry
693
7,623
2 T
Casita
444
4,484
Totals
.3,5601
01
01
0
HVAC SYSTEMS.
System Name
Qty.
Heating Type
''Min. Eff.
"Cooling T . e'
'Min. Eff.
ThermostatT we
.'Status
4 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER Setback
.New
2.5 T
1
Central Furnace
80% AFUE
Split Air Conditioner
13.0 SEER Setback
New
3 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER Setback
New
2 T
1
Split Heat Pump
8.50 HSPF
S lit Heat Pump
17.0 SEER Setback.
New
HVAC DISTRIBUTION
System Name
Heating
Cooling
Duct Location
Duct
R-Value
Ducts
Tested?
Status
4 T
Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
0 •
New
2.5 T
Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
0
New
3 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.0.
El
New
2 T Ducted
I
Ducted
JAttic, Ceiling Ins, vented
8.01
0 1
New
13
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
2
Small Gas
Kitchen Pipe Ins
40,000
50
0.58
Ma
n/a
New
MULTI -FAMILY WATER.HEATING
D,ETAILS.,
. =. ;..
HYDAONICHEATING.;SYSTE.M.
PIPING...
Control
Hot Water Piping Length "
ft
2
0
iu
v
a —
System Name
Pipe
Len th
Pipe
Diameter
Insul.
Thick.
at .
HP
Plenum
Outside
Buried
13
EnergyPro 5.1 by EnergySoft User Number. • 0166 • `RunCode: 7613-01-13T1.1 53:' 8 "15: 63276 �a a 11 of 14
N
MANDATORY MW RES. SUMMARY NR ;" -ent"! :: ` '.(Pa e 1 of 3 :_ ' MF-1 R
Project Name
Andalusia Plan 22A'
Date .
111312015
NOTE: Low-rise residential''buildings subject'to the Standards must comply with'all..applicable mandatory measures l" ed;: regardless of
the compliance approach used. More stringent energy measures listed on'the Certificateof Compliance (CF tR .CF 1 R-ADD 'or`CF
1 R-ALT Form) shall supersede the items marked with an asterisk,(*) below. This Mandatory Measures Summary 6hafl,be incorporated
into the permit documents, and the applicable features shall be'considered by all parties as"minimum corr�ponent'pertormarnce.' '
specifications whether they are shown elsewhere in the documents. or in.this summary,,Submjt afl appiicable sections bi the fvlF-1 R
Form with plans.,
Building EnWo_ 'e Measures::. =
116 a 1: Doors and windows between conditioned and unconditioned s aces are'manufactured,to U . it'air'I ka e
§116(a)4: Fenestration products (except field fabricated windows) Have a label listiho the`certified.0 Factor, certified'Solar H6403ain
Coefficient SHGC , and infiltration that "meets the. re uire,ments of 10-11 a a F`
117: Exterior doors and windows are weather-stii ed; all joints and., enetrations'.are caulked and. sealed. `
118 a : Insulationspecified or installed meets Standards for Insulating Material.. Indicate .. a and include.on CF-BR Form...
§118(i): The thermal emittance and sofar 'reflectance values of the Cool roofirig material meets'the requirements of §118(1) when the
installation of a Cool Roof is s ecified on the, CF-:1 R Form.
*§150 a : Minimum R-19 insulation'in wood -frame ceiling orequivalent U-factor.
150 b : Loose fill insulation shall conform with manufacturer's installed de$i n labeled R-Value.
*§150 c : Minimum R-13 insulation in wood -frame wall, orequivalent U-factor.
*§150 d : Minimum R-13 insulation in raised wood -frame floor ore uivalent U-factor. _.
150 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on. the.CF-1R Forma..'
150 : Mandatory Vapor barrier install.ed,.in Climate Zones 14 or, .16.......... .
§150(1): Water absorption rate for slab edge insulation material alone without: facings is no,greater than 0.30/6; water,yapor permeance, "
rate is no greater than 2.0 eermlin.ch. and. shall.be. rotected,from- physical dama a and`UV li -htdeterioration w
Firep Iaces, :Decora' iVeGas''., lancesond.Gaslo: 'Measures:_ f; '
150 e 1 A: Masonry or facto -built fire laces have a closable metal or lass door Go rin °'the entire o enm 'of the firebox.
§150(e)l B: Masonry or factory -built fireplaces'have'a combustion outside air intake;,whieh is at least six ' uareinches iri area"and i1.S.'. '
equipped with a with a readilyaccessible,.o erable, and ti ht-fittin edam er.`and or a combustion air control device. , .:;' . ".::... :.`
§150(e)2: Continuous burning pilot lights and the use'of indoor air for cooling a firebox Jacket .When-that`indoor air is vented to the
outside of the building, are. rohibited.
Space Conditionin : ', Water .Hbatin' and Plpmbm '`S stem
§110-§113: HVAC equipment, water heaters; showerhdads,'faucets and all other`regulated'appliances are certified by the -Energy -
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High=Rise residential occupancies meet the air release
valve, backf low prevention, pump* isolatipn.vailve, and recirculation loo connection re uirements.of 113,(c)5.. '
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central'fumaces,'household.cooking appliances'
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu%hr are exempt), and pool and
spa heaters.
150 h : Heating and/or cooling loads are calculated in accordance. with ASHRAE, SMACNA Or.ACCA.
150 i : Heating systems are equipped.With thermostats that meet the setback re uirements.of .Section_.112 e .._.. :.
§1500)l A: Storage gas water heaters rated with an Energy Factor no'greate(than the federal -minimal standard are'ekternally wrapped
with insulation having an installed thermal resistance of R-12 or greater. '
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the '
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table_ 150-13... 11
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping'ins'ulate'd between `heating source and indirect hot
water tank shall be insulated to Table 150.-B and Equation 1.50-A..,.
§1500)2: Pipe Pipe insulation for steam hydronic heating systems orhof water systems >l5 psi, meets'the requirements of Standards Table .
123-A.
150 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance,. and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed enfirely in
conditioned space.
150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certificatio n.Corporation.
EnergyPro 5.1 by EnerpySoft User Number-• 81 §,5 , , .- . RunCode: 2015-01-13.T11;5$:48„. JD: 6327.E • Page 12 of 14
MANDATORY ;MEASURES. SUMMARY,.Residentiaf Pa e 2 of. 3 .. ;.:MF-i R
Project Name
Date
Andalusia Plan 22A
1/1312015
§150(m)1: All air -distribution systeri ducts and plenums installed, are sealed and.insulated to meet the'requirements ofi CMC Sections
.`
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level, of
4.2 or enclosed entirely in conditioned space. Openings -shall be sealed with mastic; tape or oth'er.duct closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 11811,13 or aerosol sealant that meets the requiremof � ents U .723 if mastic ortape`is
used to seal openings reater than 1/4.inch, .the combination of mastic. and either mesh pt to a "shall be used
§150(m)1: Building cavities; support platforms for air handlers and.plenums defined or strutted with materrals other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying codi coned av bikiing cavities, and support platforms may
.
contain ducts. Ducts installed in cavities and support platforms shall not be" compressed to cause'reductions in.the cross-sectianall area
of the ducts.
§150(m)2D: Joints and seams of duct systems ah0heir,componer is shall not be sealed with. cloth -back rubber adhesive.du`ct.tapes'
unless such tape is used in gombination with mastic and. draw.bands.
150 m 7: Exhaust fans stems hay..e back draft or automatiaclam e. rs._
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible;'manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, includino that du0o sunlight, moisture equipment maintenance, and wind.
Cellular foam insulation shall be protected as above' or painted with a coaling fhat is v a r `retardant and provides shielding from solar '
radiation that can cause degradation of the material..
150 m 10: Flexible ducts cannot have, porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard'62:2-2007 Ventilation and Accept4ble'lndoor Air
Quality in Low -Rise Residential Buildings. Window operation isnot a permissible method of providing the Whole Building Ventilation'
required in Section4 of -that Standard..
Pool and S a llleafing S stems_and E..ui rfine"easures: '
§114(a): Any pool or spa heating system'sKA11 be certified 'tofiave;'a thermal efficiency that complies with theAppliance 1=fficiency
Regulations; an on -off switch mounted outside of�the heater; a permanent weatherproof plate'of card with operating instructions; an
shall not use electric resistance heating or a pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 3fi' of pipe between filter and heater, or dedicated suction '
and return lines, or built-up connections for future solar, heating.
114 b 2: Outdoor pools or.s as that.have a.h.eat pump or gas heater shall have,a cover.._; ,..;,..
§114(b)3: Pools shall have directionaT'iniets'that adequately mix the pool water `and a1inie switch fhat will allow all pumps'fo be set or
programmed to rurionly during off-peak electric demand,periods.
150 : Residential, pool systems ore ui ment meet thep um sizin , flow rate, pipin. , filters, and valve, re uirements..of §15.Qj .
Residential Lighting .Measures: -
150 k 1: High efficacy luminaires or LED Light En` the withAnte ral Heat Sink has an efficacy that is,no lower than the efficacies
contained in Table 150-C and is not a low efficacy,luminaire.as' s ecified. by § 150(k)2. .
150 k 3: The wattage of permanently installed.luminaires shall, be_'det0mined :as s `'ecified by" ' 130 d . '
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greafer'shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 150 k .
150 k 7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be '
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in.the kitchen are controlled by a manual on occupant '
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number. • 8165 . _ RunCode: 2015-01-13T1J.:50:48 !D: 63276 .. .. ... ;- .. Page 13 of 14 .
MANDATORY MEASI .RES,SU...MMARY `Resideni"ial .. Pa a 3�6f 3 ' MF-1R
Project Name
Date
Andalusia Plan 22A
1/1312015
§150(k)10: Permanently installed tuminaires in bathrooms, attached and defached garages, laundryrooms; closets artd utility rooms-`
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.: .
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, � "' .'
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy Iuminaires.shall be
-by
allowed provided they are controlled.by either a dimmer switch that complies with the.applicable requirements'of §119 or a manual
on occupant sensor that complies with the applicable requirements of §119: EXCEPTION 2. Lighting incJetached storage building less
than 1000 square feet located on a.residential site is not re, uired,to com I with 150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall b0isted'for zero clearance: insufation`contad (IC) by'Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies. the lure iunair� is airtight with,_air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283;` and be�sealed "with a gasket or'caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential bui)dings'with four or more''-
dwelling units, entrances, balconies, and porches, which are permanently mountedto a residential:bwlding or to other buildings°on the ; Y
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires'hallbe allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the,motion.,sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the. photocontrgl;..OR an '
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2:, Outdoor .
luminaires used to comply with Exception1 to §150(k)13 may be controlled by a temporary override switch which bypasses the motion. .
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed_
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the'California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw' -base socket, and consume no
more than five watts of power as determined accordin to 130 d .
§150(k)15: Lighting for parking lots and carports with'a total of for 8 or more vehicles per.site shall comply with: the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall corriply'with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces' *of low-rise residential buildings with four or mo'r'e .
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be, allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable re uirements of 119.
EnergyPro 5.1 by EnergySoft User Number., 8165 RunCode:. 2015r01-13T1.1; 53, 48 ` ", - ID: 63276 Page 14 of 14.
BUILDING ENERGY ANALV$1'9 REPORT _ `' ..
PROJECT:
Andalusia Plan 22B
Coral Mountains 75' Lots
La Quinta, CA
Project Designer:
Pekarek-Crandell, lnc
31411 Camino Capistrano
San Juan Capistrano, CA 92675
- 949.487.2320
Report Prepared by:
Gangyi Zhou
GMEP Engineers
4400 Campus Drive
Newport Beach, CA 92660
9497521612
Job Number:,
63276
Date:
1 /14/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. ,
This program developed by EnergySoft, LLC — www.energysoft.com.
EneryyPro 5.1 by EnergySoft User Number. 8165 RunCode: Z015-01-14.T12.04:0$_. `'lD:.03276
User Number: 8165
I.Energypro 5.1 by EnergySoft
Job Number:
ID: 63276
PERFORMANCE CERTIFICATE. Residential : ,:. :.Part 1 of 5
....CF* 1.R
Project Name
Andalusia Plan 228
Building Type m Single Family 0 A'dditiori Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111412015
Project Address
Coral Mountains 75' Lots La Quinta ...,,
,::
California Energy Climate Zone
CA Climate Zone.15; ..
Total Cond. Floor Area
:.. : 3, 560 .
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details..
INSULATION
Construction, Type _.. :,. _ ..
Area Special
Cavity(ft� . Features. see. Part 2 .of 5
Status...,
Wall Wood Framed
R-19 2,286 Ext=R-4.0
New
Roof Wood Framed Attic
R-30 3,187 Radiant Barrier
New
FENESTRATION U- Exterior
Orientation Area(ft) .:Factor ;SHGC„ Overhan Sidefins...Shades ., ..
Status
Front (N) 14.0 0.300
0.20 none none Bug Screen
New
Front (N) 15.0 0.300
0.17 10.0 none Bug Screen
New
Front (N) 37.0 0.300
0.17 10.0 none Bug Screen
New
Left (E) 96.0 0.320
0.30 10.0 none Bug Screen
New
Left (E) 33.8 0.300
0.17 none none Bug Screen
New
Left (E) 30.3 0.320
0.30 10.0 none Bug Screen
New
Left (E) 3.1 0.380
0.35 none none Bug Screen
New
Right (Vlq 192.0 0.320
0.30 10.0 none Bug Screen
New
Right (VlQ 64.0 0.320
0.30 none none Bug Screen
New
Rear (S) 48.0 0.320
0.30 10.0 none Bug Screen
New
Front (N) 16.5 0.300
0.17 6.0 none Bug Screen
New
HVAC SYSTEMS
Qty. Heating Min. Eff
. Cooling Min. Eff. ,_. Thermostat,
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback
New
1 Central Furnace 80 % AFUE
Split Air Conditioner 13.0 SEER Setback
New
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heatin'Cooling
Duct
Duct Location ,R-Value ._
, .Status.,.. ,.z.
4 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
2.5 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
3 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution
Status
2 Small Gas 50
0.58 Kitchen Pipe Ins
New
Energ Pro5.1 b Energ Soft -User Number. 8165
;;RunCoder 2015-01.-14T1230As09-, .. `..__lD.-,03276 .- .';;., ..;
Page 3 of 14
PERFORMAN'08,MATIFICAT 1
E:,..J3e9(0en, a.- .(�art.! of 5)
-113
QF—
Project Name
Andalusia Plan 22B
Building Type 0 Single'Family 0 Addition Alo' ne
13 Multi Family 0 Existing+ Addition/Alteration
Date
111412015
Project Address
Coral Mountains 75'Lots La pyinta
California Energy Climate Zone
CA Climate Zone...1.5
Total Cond. Floor Area
3,560
Addition
n1a
V —of Stories
I
FIELD INSPPECTION"ENERGY CMECKUST
El Yes 0 No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
El Yes 0 No Special Features.7- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction, Type.
Area Special
Cavity (ft) Features.(seq. Part 24 of 5)
Status
FENESTRATIOU U- Exterior
Orientation, Area(ft)- factor $HQC.... OVerh@ng--$idIqfins Status...
Right (Vto 96.0 0.320
0.30 8.0 none Bug Screen
New
Rear (S) 108.5 0.300
0.17 none none Bug Screen
New
Front (N) 48.0 0.320
0.30 10.0 none Bug Screen
New
Front (N) 59.5 0.300
0.17 none none Bug Screen
New
Right (K9 11.0 0.300
0.17 10.0 none Bug Screen
New
Right (1/10 11.0 0.300
0.17 none none Bug Screen
New
Front (N) 11.0 0.300
0.17 8.0 none Bug Screen
New
HVAC SYSTEMS
Qty. Heating Min. gff
Cooling Min. Eff Thermostat Status.
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 17.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Lopati.99. -R-Valpe, Status,
2T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
WATER HEATING4 4. .4
Oty. Type Gallons Min. Eff Distribution.— Status
EnefgyPro 5. 1 by EnergySoft User'NurrjPer 81'05
-R ode: 2015!�Q144F
unC 12,0Z09 63276,
-Page 4 of 14'
PERFORMANCE CERTI"FICAT,E Rsiden,taL A_;; .. , .. (Part 2 of 5) CF-1 R .
Project Name
Andalusia Plan 22B
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration"
Date
111412015
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification, and documentation.submitted.
Compliance for all orientations is specified see sectioh'151 (c)`2 of the'Standards "and section`7.6.2 of the Residential Compliance Manual. "
The Roof R-30 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF74R form„for;each of the measures. listed below_for final.to. be.. iven..:,
The Cooling System 3 T includes credit for a12.5 EER Condenser. "A certified HERS rater mustfield verify the installation of the correct Condensei.
The HVAC System 4 T includes credit for Verified Fan "Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 4 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 4 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
The Cooling System 2.5 T includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 2.5 T includes credit for.Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field "verification is required.
The HVAC System 2.5 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 2.5 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specked criteria.
The Cooling System 3 T includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 3 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Erie Pro 5.1 by EnergySoft User Number 8165 .".: ,RunC de: 2015-b1-14T12:b4:09 '1D:. �3276 Pa e 6 of 14
PERFORMANCE,CERTIFICAT"E:, Residential ;(Part 2 of 5) CF-1 R.
Project Name
Andalusia Plan .22B ..
Building Type ® Single Family ❑ Addition Alorie" '` `'
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111412015
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation,. and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation, submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-48 .form. for each, of_the.r e..asures, listed.below fpr final to be., iven..,.
Compliance credit for quality installation Of insulation has been used. HERS field verification is "required.
The HVAC System 3 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System..
The HVAC System 3 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specked criteria.
The Cooling System 2 T includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 2 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The H VAC System 2 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 2 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specked criteria.
Ene Pro5.1 b Ene Soft ''User Number. `ti16b " 12unCode: 2015-�1-14T13:04:09 : .; .'. `D:.6327.6 Pa e 6 of 14
PERFORMANCE' CERTIFICATE. ,.Residential. (Part.3 of 5) CF-1 R.
Project Name
Building Type m Single Family :0 Addition Alone
Date
Andalusia Plan 22B
❑ Multi Family ❑ Existing+ Addition/Alteration
1111412015
ANNUAL ENERGY.USE: SUMMARY, ,:,;
Standard Facing Margin 'Facing ""Margin Facing Margin Facing Margin
TDV (kBtu/ft2- r) North East South west
Space Heating 4.09 3.76 0.33 4.05 0.04 3.32 0.77 3.37 0.72
Space Cooling 54.46 39.78 14.67 39.12 15.33 39.62 14.84 39.71 14.74
Fans 10.88 9.93 0.95 9.81 1.07 9.95 0.92 9.92 0.46
Domestic Hot Water 10.25 13.23 -2.99 13.23 -2.99 13.23 -2.99 13.23 -2.99
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Totals 79.67 66.70 12.97 66.22 13.45 66.12 13.55 66.24 13.43
Percent Better Than,,Standard 16.3 % 16..9 %, .; .17.0 �.. ,: - ....:. ......16.9
BUILDING COMPLIES-H,ERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: AOFourOrientations Ext. Walls/Roof Wall Area Area .
Number of Dwelling Units: 1.00 (N) 1,120 201
Fuel Available at Site: Natural Gas (E) 360 163
Raised Floor Area: o (S) 925 157
Slab on Grade Area: o (IM 776 374
Average Ceiling Height: 12.0 Roof 3,187 0
Fenestration Average U-Factor: 0.31 TOTAL: 895
Average SHGC:.,. ...:. 0.25 ... .. Fenestration/CFA Ratio,,..
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company GMEP Engineers
111412015
Address 4400 Campus Drive Name Gangyi Zhou
Cit /S ate/Zip Newport Beach, CA 92660 Phone 9497521612 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Pekarek-Crandell,Inc
Address 31411 Camino Capistrano Name
City/State/Zip San Juan Capistrano, CA 92675 Phone 949.487.2320 Signed License # Date'
EnemyPrp 5.1 by Ene Soft User Num6er.•'8165` -RunCode: 1015-01-14T12r04 09 ID: 63276 :Page 7 of 14
CERTIFICATEOF COMPLIAN,Ct.Residential ;(Parf 4 of.5) CF-1R
Project Name
Andalusia Plan 228 .
Building Type 10 Single Family O Addition`Alone"
❑ Multi Family ❑ Existing+ Addition/Alteration,',
Date - -
1/14/2015.
OPAQUE SURFACE,DETAILS.
-
Surface
Type
Area
U-
Factor
Insulation
Azm'
Tilt
Status
Joint Appendix`'
4
"
Location/Comments
Cavit
Exterior
Frame
Interior
Frame
Wall
399
0.057
R-19
4.0
None
0
90
New
4.3.1-A5
Great RoorrilKit6henlEntry
Wall
157
0.057
R-19
4.0
None
90
90
New
4.3.1-A5
Great Room/Kitchen/Entry
Wall
99
0.057
R-19
4.0
None
270
90
New
4.3.1-A5
Great RoomlKitchentEntry
Wall
72
0.057
R-19
4.0
None
180
90
New
4.3.1-A5
Great Room/Kitchen/Ent
Roof
1,100
0.031
R-30
0
0 New
4.2.1-A20
Great Room/Kitchen/Ent
Wall
84
0.057
R-19
4.0
None
0
90
New
4.3.1-A5
Master Suite/all 1
Wall
40
0.057
R-19
4.0
None
90
90
New
4.3,1-A5
Master'Suite71la/1.9_,
Wall
94
0.057
R-19
4.0
None
270
90
New
4.3.1-A5.
Master SuiteMall I.
Wall
399
0.057
R-19
4.0
None
.180
90,
New.
4.3.1-A5'
Master SuiteA6il.1
Roof
950
0.031
R-30 -
0
0 New
4.2.1-A20
Master SuiteM ll 1 °
Wall
245
0.057
R-19
4.0
None
0
90
New
4.3.1-A5
Bed3lJrSuite/Lauhd".-p
Wall
143
0.057
R-19
4.0
None
270
o90
New
4.3.1-A5
Bed3lJr SuitelLaqpdrylHa.
Wall
298
0.057
R-19
4.0.
None
180
90
New '.
4.3.1-A5
Bed3lJr Suitekaundry/Ha
Roof
693
0.031
R-30
0
0 New
4.2.1-A20
Bed3/Jr Suite/Laundry/Ha
Wall
192
0.057
R-19
4.0
1 None
0
90
New
4.3.1-A5
Casita
Wall
66
0.057.
R-,1.9 .- ....4.0
. -_
IVori&
`,. ; : ,
270
90
New :'
4.3.1=A5 ......` • •'
. Casita. .. , .- :� . •'.>. `
FENESTRATION
SURFACE
DETAILS
ID
Type
Area "
U Factor
'T'SHGC
'A "
Status `.
GlazingType.'.
LocaUori(Coinm.ents,.'
1
Window
4.0
0.300
NFRC
0.20
NFRC
0
New Fixed
Glass,
Great Room/KitcherVEntrylMo
2 'Window
4.0
0.300
NFRC
.0.20
NFRC
; -0
New;Fixed
Glass_
Great RooinACitchenlEntry/Nlo;
3
Window
6.0
0.300
NFRC.
0.20
NFRC
0
New_ .• Fixed
Glass .:'.:.
Great Roorri/KitchenlEntiylMo
4
Window
15.0
0.300
NFRC
0:17
NFRC
0
New' '. ' ,Single
Puri-* 7
Great RopnMtchgnlEntry/Mo
5
Window
37.0
0.300
NFRC
0.17
NFRC ,:..
0
New. ". FG/MITER
'.. `'
Great Room/ICitchen%Entrymp ,
6
Window
96.0
0.320
NFRC
0.30
NFRC
790
New. -. Sliding,
Glass, Door `. '' ;:,
Great Room/Kifchen/Entry%Mo -
7
Window
33.8
0.300
NFRC
4.17
NFRC
90
New.....,, FG/MITER.:.
GreafRoom/Kitchen/EntrylMo_.
8
Window
30.3
0.320
NFRC
0.36
NFRC . ,..
90
Nee' ` `' French
Glass Door ' ;` ;
.Great Roorn/KitizhenlEntry/IVIo
9
Window
3.1
0.380
NFRC..
._ 0.35
NFRC-,,:.
'...90
New' RndFized
,;.
GreatRoom/Kitchen/Entry/Mon
10
Window
192.0
0.320
NFRC
0.30
NFRC..,
. '270
New, . . .Sliding
Glass Door . H,
Great'Room/Kitchen/Eniry/Mo.
11
Window
64.0
- 0.320
NFRC
0:3,0
NFRC...:
270
New .- Fixed
Glass 0:3zo 3 . ' ;:,.;
Great_ RoorrMtchei►/EntrylWo
12
Window
48.0 .
0.320,
NFRC
,0.30
NFRC
180'
New ' `Sliding
Glass Door
Great Roorri7Kitc4en1Entry/Mo_
13
Window
16.5
0.300.
NFRC
0.17
NFRC `
: 0
New Caserrienf
1. .'
Master SuiteMall 1
14 .
Window
96.0
0.320
NFRC
0.30
NFRC.
270
New Sliding
Glass. Door .; ,. ; .
Nlaster'suite/Hall 1
15
Window
11.0
0.300
NFRC
0.17
NFRC •'
180
New Casement
: ;;
MasterSuiteMall.l ,_.
16
Window
11.0
0.300
NFRC
0.17
NFRC
180
New Casement
Master Suite/all 1
(1) "U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: .1.16-8 = Default Table from Standards, NFRC =.Labeled Value
EXTERIOR
SHAD,ING.DETAILS
ID
Exterior Shade Type
SHGC
Window
Overhan
Left Fin'
Right Fin '
H t
Wd
Len
H t
LExt
REA
Dist
. Len'
H t
Dist
Len
H t
1
Bug Screen
0.76
,
2
Bug Screen
0.76
3
Bug Screen
0.76
4
IBug Screen
0.76
5.01
3.0
-10.0
0.1
3.0
3.0
5
Bug Screen
0.76
7.0
5.3
10.0
0.1
3.01
3.0
-
6
Bug Screen
0.76
8.0
12.0
10.01
0.1
3.0
" 3.0
7
Bug Screen
0.76
8
Bug Screen
0.76
8:0
4.0
10.0
0.1
3.0
3.0
9 •
Bug Screen
0.76
-
10
Bug Screen
0.76
10.0
16.0
10.0
0.1
3.0
3.0
11
Bug Screen
0.76
12
Bug Screen
0.76
8.0
6.0
10.0
0.1
: 3.0
3.0
13
Bug Screen
0.76
5.5
3.0
6.0
0.1
6.0
6.0
14
Bug Screen
0.76
8.0
12.0
8.0
0.1
2.0
2.0
15
Bug Screen 1
0.761-
' 16
Bug Screen 1
0.76
Ene Pro5.1 b Ene "Soft' 'Us6?'1Vumbec°8165 ; ...<.;17unCode: 201'S-01-14T12;04r09 :::ib` 63276 Pa de 8 of 14`
3
CERTIFICATE OF -.COMPLIANCE: Residential Part.4 of 5 CF-1 R
Project Name
Andalusia Plan 22B
Building Type m Single Family D Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
'Date '
9/14/2Q1.5
OPAQUE SURFACE
DETAILS...
Surface
Type
Area
U-
Factor
Insulation
Azm
Tilt
Status
Joint Appendix
4
Location/Comments
Cavity
Exterior
Frame
Interior
Frame
Roof
444
0.031
R-30
0
0 New
4.2.1-A20
Casita
FENESTRATION.SURFACE
DETAILS
ID
Type
Area
U-Factor
"SHGC
Am''
Status'
` : ,: ;;;Glazin. "T =
`:Location/Comments
17
Window
16.5
0.300
NFRC
0..17
NFRC
.180
New .. Casement
Master'Suite/Hall 1
18
Window
16.5
0.300
NFRC
0.17
NFRC
180
New Casement
Master Suite/Hall 1 '
19
Window
16.5
0.300
NFRC
.0.17
NFRC
.180
New Casement
Master Suite/Hall 1.-
20
Window
10.0
0.300
NFRC
0.17
NFRC
180
New Casement
Master Suite/Hall 1
21
Window
48.0
0.320
NFRC
0.30
NFRC
0
New Sliding
Glass Door ':'
8ed3lJrSuite/LaundrylHall 2
22
Window
27.5
0.300
NFRC
0.17
NFRC
0
New Casement
_
Oed3/Jr Suite7Laund /Hall 2
23
Window
4.5
0.300
NFRC
0.17
NFRC
. 0
New Casement,
Bed3/Jr Suite/Laundry/Hall 2'
24
Window
11.0
0.300
NFRC
0.17
NFRC
270
New Casement
Bed3%Jr Suite/LaundryMall 2.
25
Window
11.0
0.300
NFRC
0.17
NFRC
270
New Casement.
Bed3/JrSuite/Laundry/Hall2
26
Window
4.5
0.300
NFRC
0.17
NFRC
1B0
New Casement
_
Bed3/Jr SuitelLaundryIHall2
27
Window
4.5
0.300
NFRC
0.17
NFRC
180
New 'I Casement
Bed3/Jr Suite/LaunZlryMal 2 .'
28
Window
4.5
0.300
NFRC
0.17
NFRC
180
New Casement
Bed3/Jr Suite/Laundry/Hall
29
Window
4.5
0.300
NFRC
0.17
NFRC
180
New Casement
Bed3/Jr Suite/Lauridrymall 2
30
Window
4.5
0.300
NFRC
0.17
NFRC.
180
New Casement
Bed3/Jr Suite/LaunddryMall 21
31
Window
4.5
0.300
NFRC
0.17
NFRC
180
New Casement
Bed3/Jr Suite/LaundryMall 2
32
Window
11.0
0.300
NFRC
0.17
NFRC
0
New Casement
Casita
(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
.
EXTERIOR
SHADING DETAILS
ID
Exterior Shade T e
SHGC
Window
Ove hang
Left Fin
Right Fin
H t
Wd
Len
H t
LExt
RExt
Dist
Len
H t
Dist
Len
H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
8.0
6.0
10.01
0.1
3.01
3.0
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
5.5
2.0
10.0
0.1
3.0
3.0
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
31 IBug
Screen
0.76
32 JBug
Screen
0.76
5.5
2.0
8.0
0.1
2.0
2.0
EnergyPro 5.1 by Ene. Soft User N"4,mer.'6165 .; RunCode: 2015.01-14T12:Q409 - ...,...ID: 63276 .. ,_; . 'Page 9 of 14
- - - - •
Project
Plan 22B
ri Single Family '0 .. . . -
0 Multi Family 0 Existing+ Addition/Alteration
OPAQUEAndalusia
MM
Joint Appendix
4
Location/Comments
FENESTRATION
SURWE
DETAILS
MEN.. R- . - . .. .
-.MME
CERTIFICATE OF COMPIAN.E:.Residential. (Part 5 of -5) CF-1 R
Project Name
Andalusia Plan 22B
Building Type m Single Family d Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1/14/2015
BUILDING ZONE INFORMATION
,
System Name
Zone Name
Floor Area ft
Volume
Year Built
New
Existinq
Altered
Removed
4 T
Great Room, Entry, Kitchen, Wet
1,273
17,949
2.5 T
Master Suite, Master Bath
1,150
12,650
3 T
Bed3, Jr Suite. Laundry
693
7,623
2 T
Casita
444
4,484
Totals
3,560
; ;_.0
0,
0
HVAC SYSTEMS
System Name
Qty.
I 'Heating Type
Min. Eff.
Coolie Type `'
-Min. Eff. "
'Thermostat Type' `'
'Status
4 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
.15.0 SEER
Setback
New
2.5 T
1
Central Furnace
80 % AFUE
Split Air Conditioner
13.0 SEER
Setback
New
3 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER
Setback. ,
New
2 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
17.0 SEER
Setback
New
HVAC DISTRIBUTION ..
System Name
Heating
Coolinq
Duct Location
Duct
R-Value
Ducts
Tested?
Status
4 T
Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
m •
New
2.5 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
m
New
3 T Ducted
Ducted
Attic, Ceiling Ins, vented .
8.0.
El
New
2 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
EI INew
13
WATER HEATING SYSTEMS_
S stem Name
Ot .
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
2
Small Gas
Kitchen Pipe Ins
40,000
50
0.58
n/a
n/a
New
MULTI -FAMILY WATER,HEATING
DETAILS
°.:`
HYDRONIC
HEATING SYSTEM
PIPING .. _
Control
Hot Water Piping Length
ft
0
Mo
N
a
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Ot .
HP
Plenum
Outside
Buried
13
Ene Pro 5.1 b Ene Soft User Number V65, . .'r:. RenCode.' 2015-01-14T12:04`09 ;ID: 63276 pa a 11 of 14
MANDATORY MEA$URES,SUMMARY .1esir ent'ial ` .,age ,1 of
Project Name
Andalusia Plan 22B
Date
111412015
NOTE: Low-rise residential buildings subjectto'the Standards rriust complywith all'appticable mandatory'measures listed; s`of "
the compliance approach used. More stringent energy measures listed on the Certificate of,Compliance (CF-1 R, CF-1 R-ADD, or CF- ,:'
1 R-ALT Form) shall supersede the items marked with an asterisk (:) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere.in the documents or in this summary. Submit all applicable sections of the MF-1 R
Form with plans.
Building Envelo"e Tvleasures
116 a 1: Doors and windows between conditioned and, unconditioned ,$, aces are manufactured to limit air (eaka '
§116(a)4: Fenestration products (except field -fabricated wiridows) have a label listing the -certified' U'Factor, certified Solar Heat Gain `
Coefficient SHGC , and infiltration that meets the re uirements:of . 1'0.-111.-
117: Exterior doors and windows are weather-stripped; all_•oints and penetrations are. caulked and 1dealed,:_ ._ _...`.7.
118 a : Insulations ecified or installed meets Standar s for In$ulatin .Material. Indicate tr a and include on. CF-6R Form
§118(i): The thermal emittance and solar refl6daince`values'of the cool roofing material meet's the requirements of §118(i) when'the
installation of a Cool Roof is specified on the CF-1.R Form.
* 150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor.
150 b : Loose fill insulation shall conform with manufacturer's,installed design Iabeled.R-Value,
* 150 c : Minimum R-13 insulation in wood -frame wall ore uivaler)'U-factor. ...
* 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. ,
150 f : Air retarding wrap is tested, labeled, and installed according to.ASTM E1,677-95.•20,00. when. s ecified.orithe CF-lR Form.
150 : Mandatory Vapor barrier installed -in Climate..Zones. 14, or 16..:.
§150(I): Water absorption rate for slab etlge insulation material alone without facings is no,'greater`than 0 3% :water vapor permeance.j
rate is no greater than 2.Q. erm/in..ch.and shall be -protected from, h. sical dama e and UV li ht detenoration
Fire laces, Decofaliive Gas A . liances and Gas Lo Meaeures:: ;: _ • t .: .
150 a 1A: Mason or facto built. fire laces shave closable metal or lass doorc'ovenn 'the entire o rtm ofithe firepox.. ,
§150(e)i B: Masonry or factory -built fireplaces ,have a conibustion outside'air intake, which'is at least six $guare-inches in.area'an-d is
.
equipped with a with.a readilyaccessible, operable, and. ti ht-fittin damper and or, a. combustion air control device.
§150(e)2: Continuous burning pilot lights and the use'of indoor air for,coot"ng a fire "ox Jacket when"that indoor air is vented to tlie" ." '
outside of the buildin , areProhibited, ,. .. :..
Space Conditioning,Vlater'Heating`and P�umbin 5 stem Measures:''
§110-§113: HVAC equipment, waterheaters,'showerheads,'faucets and all other`regulated appliandesare certified by' the 'En ergy`
Commission. - R
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release'
valve, backflow prevention, pump isolation valve, and recirculation.,loo 'connection requirements of 1'13. c 5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, Household cooking appliances '
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters. `
150 h :.Heatin and/or cooling loads are calculated in accordance with ASHRAE, S:MACNA,or ACCA.
150 i : Heating s stems are equipped with thermostats that meet the setback re uirementsof Section 112(c).
§1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or. reater..
§1500)1 B: Unfired storage tanks, such as storage: tanks or backup tanks for solar water -heating system; or other indirect hot water
tanks have R-12 external insulation or R-16 internal: insulation where the internal insulation R-value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater.tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per..$tandards Table,150-B.
§1500)2: Cooling system piping (suction, chilled water, or brine lines)'and°piping insulated between heating"source and indirecthot
water tank shall be insulated to Table 150-Band Equation 150-A. `
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements'of Standards Table
123-A. , '
150 ' 3A: Insulation is protected from dama e, including that due to sunlight,. moi sture, e• ui ment maintenance,.and wind. -
§150Q)3A: Insulation for, chilled water piping. and refrigerant suction lines includes a vapor'retardant or isenclosed entirely"in
conditioned space.
150 ' 4: Solar water -heating systems and/or collectors ,are certified.by the Solar Rating and Certification Corporation.
EnergyPro•5.1 by EnergySoft. ,.,;,_, „ID:.age 12of 143
P
MANDATORY MEASU,_RES.. SUMMARY Residential :: ` I'a `e 2 of 3 MF 1 R ,
Project Name
Date
Andalusia ' Plan.228 _ -
1/1412015
§150(m)1: All air-distribution'systerri ducts and ple'riurris`installed,`are sealed and insuiated to mebf the requirements of CMC Sections "
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system .that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the'requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the. combination of mastic and. either mesh or tape shallbe.used .
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or'oonstructed with materials othef than' sealetl
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may' '
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and "their components shallnot.4e sealed With cloth back robber adhesive duct tapes '
unless such tape is used in combination.,.with. mastic and. draw kiarids.. '
1 50rri 7: Exhaust fan s stems have back draft or automatic dampers.' .
§150(m)8: Gravity ventilating systems serving conditioned space'have either automatic or`readily accessible; Nianually'operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that ,due, _to sunlight, moisture equipment n�amtennce, and wind. ' '
"a
Cellular foam insulation shall be protected as above or'painted with coating •tliat is water "retardant and provides"shielding from solar'
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have orous.inner_cores..,;.
§150(o): All dwelling units shall meet the requirbnients•of ANSI/ASHRAE Standard 62 2-2007Ventilation and Acceptable I.ndoor;Air .
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of proViding'the 1Nhole'Building Ventiiation
required in Section. 4.of..that Standard
Pool and S a:.Heatin S stems. �nd.E; ui 'ment:Measures z :.
§114(a): Any pool or spa beating 'system'shall beicertified io`ha46- a thermal efficiericy'that.comjilies With the Appliance Efficiency
Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plaie or card with operating instructions, `and r
shall not use electric resistance heating or a. ilo..t.li ht:.:-._
§114(b)1: Any pool or spa heating equipment shall be installed With. atleast`36" of pipe between filter and heater, or dedicat6d'suction`
and return lines, or built-up connections for future solar..heatin .
114 b 2: Outdoor pools ors as that have a heat:: um or, as heater shall have a.corer. •:....:.
§114(b)3: Pools shall have directional inlets thatadequa'tely"n'iz the pool water; -and afime switch'fhat will allow'all pumps to be setor
programmed to run only during off-peak electric demand eri.od5._ .
150 :Residential, ool s ste.ms or..e. ui merit. tneet,the um sizin ,flow rate., i in ; fi.lters, and _. valve reuiremerits of 1. .50, . ,
Residential L!g htin Measures:
§150(k)1: High efficacy lurriinaires*or"tED Llght`Engine withlrsteg?al Heat -Sink has an efficacy that is no lovVer than'the efficacies`
contained in Table 150-C and is not a low efficacy luminaire ass ecified by § 1 50k 2. -
150 k 3: The wattage of permanently installed luminaires shall be determined as specified by 130 d . ;..:
§150(k)4: Ballasts for fluorescent lamps rated 13 Wafts or greater shall be electronic and shall have ah'butput frequency no°less than
20 kHz. '
§150(k)5: Permanently installed night lights and night lights integral to a permariently'installed luminaire or exhaust fan.shall contain.. .
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line=voltage socket or line= '
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
1 50k 6: Lighting integral to exhaust fans, in rooms other than, kitchens, shall meet the applicable requirements Qf.§ 1 50k .
150 k 7: All switching devices and controls shall meet -the requirements of 150 k 7.
§150(k)8: A minimum. of 50 percent of the total rated wattage of permanently installed lighting in kitchens 'shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy' luminaires in.the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor..
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
.. . 1
EnergyPro 5.1 by EnergySoq. ; :User, Number. 8105 _,.:. RunCode: 2013-01 14T12 64:6.9 lQ: 63276 Page 13
MANDATORY MEAS'URES:.SUMMARY..Resldenti8d .. ; .. :...... Pa a '3 of 3). MF-1 R
Project Name
Date
Andalusia Plan 22B
111412015
§150(k)10: Permanently installed luminaires in bathrooms, attached and'detached garages,'laundry rooms, close s' and' utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)1,1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of.§119, or by a manual-. .
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with § 150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for ero clearance insulation contact (ICJ by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label.that certifies the,lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be'sealed with a`gaskei or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in, low-rise' residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the.
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that .
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the Photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (FMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to., 130 d .
§150(k)15: Lighting for parking lots and carports with a tdtal of for 8 or`riiore vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146..
§150(k)16: Permanently installed lighting in the enclosed; non -dwelling spaces of low-rise residential buildings with 'four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements. of,119.
EnergyPro 5.1 by. EnergySoft U.ser Number 8165. , ..: RunCode:"2615-01 14T12 04r09. #iD:, 63276 Page 14 of 14 ":
BUILDING ENERGY ANALYSIS REPORT
PROJECT
• Andalusia Plan 22-C
r
Coral Mountains -75'. Lots
' La'Quinta, CA
Project Designer:
Pekarek-Crandell, lnc
31411 Camino Capistrano
San Juan Capistrano, CA 92675
949.487.2320 r ,
Report Prepared by:
Gangyi Zhou . 1
GMEP Engineers
4400 Campus Drive
Newport Beach, CA`92660 -
• Job Number:
63276
Date:
1/13/2015
•
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is'
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
d
Fn'ergyPro 5.1 by Energ
KSbft User Numbe"r.' ,81;65 RunCode:'2015-Q1.-13T1,1;53 27 ;: ID:.63276'
PERFORMANCE CERTIFICATE:;Residential
:. Part 1. of 5
`. ...F-1 R
Project Name
Andalusia Plan 22-C
Building Type 0 Single Family 0 Addition Alone' ` - -
❑ Multi Family ❑ Existing+ Addition/Alteration
Date'
111312015
Project Address
Coral Mountains 75' Lots ; La. Quinta ..: ,;
California Energy Climate Zone
. .CA Climate Zone .15 ...-
Total Cond. Floor Area
. 3, 599 ., ..
Addition
n/a
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
El Yes ❑ No HERS Measures -- If Yes, A CF-413 must be provided per Part 2 of 5 of this form.
0 Yes ❑ No Special Features -- If Yes, see. Part 2 of 5 of this,forcn for details...... ,
INSULATION
Construction. Type
Area Special
Cavity ( Features.. see Part 2 of 5
Status
Wall Wood Framed R-19 2,713 Ext=R-4.0
New
Roof Wood Framed Attic R-30 3,465 Radiant Barrier
New
FENESTRATION U- Exterior
Orientation. Areq(ft2). Factor .SHGC .0yefting Si0eflips . Shades
Status.,... ,
Front (N) 14.0 0.300 0.20 none none Bug Screen
New
Front (N) 37.0 0.300 0.17 none none Bug Screen
New
Front (N) 15.0 0.300 0.17 none none Bug Screen
New
Left (E) 96.0 0.320 0.30 10.0 none Bug Screen
New
Left (E) 33.8 0.300 0.17 none none Bug Screen
New
Left (E) 30.3 0.320 0.30 none none Bug Screen
New
Left (E) 4.5 0.380 0.35 none none Bug Screen
New
Right (149 192.0 0.320 0.30 10.0 none Bug Screen
New
Right (M 56.4 0.320 0.30 none none Bug Screen
New
Rear (S) 48.0 0.320 0.30 none none Bug Screen
New
Front (N) 87.0 0.300 0.17 none none Bug Screen
New
HVAC SYSTEMS
Qty. Heating Min. Eff. __Conlin__CpqI1inq
Min. Eff Thermostat ..
Status.
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback
New
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback
New
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 17.0 SEER Setback
New
HVAC DISTRIBUTION
Location ....: -..; :.. Heating
Duct
Cooling Duct Location _ .,: ,; . _ . _R-Value_. ,.
,Status
4 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
4 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
2 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
WATER HEATING
Qty. Type Gallons, _.Min.. Eff ,.Distribution.,..,.
,Status.
2 Small Gas 50
0.58 Kitchen Pipe Ins
New
EnergyPro 5.1 Oy Ene' g Soft User .Al0mber'8165 ' ,. -.
,-R MCode: 201"l-13T1.1:53r27 `. . 10 6$276
PERFORMANCE_ CERTI,FICATE.. Residential :=: _ : ; . (Part'! .of.5
CF-1 R
Project Name
Andalusia Plan 22-C
Building Type 0 Single Family ❑ Additidn Aldne
❑ Multi Family ❑ Existing+ Addition/Alteration
Date'
111312015
Project Address
Coral Mountains 75' Lots La Quints.
California Energy Climate Zone
CA Climate,Zone 15, ..;
Total Cond. Floor Area
3,599
Addition
n/a : _.
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
El Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special`
Construction . T. a .. Cavity .( Features_, see.Part 2 of 5 $tatus,.. .
FENESTRATION U- Exterior
Orientation Area( ., Factor. „$HGC ._4verhan Sidefins ,.Shades , . :Status,_...;
Front (N) 48.0 0.320 0.30 none none Bug Screen New
Right (lN) 96.0 0.320 0.30 8.0 none Bug Screen New
Rear (S) 108.5 0.300 0.17 none none Bug Screen New
Right (VV) 22.0 0.300 0.17 none none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff ,_.. Cooltn
1 Split Heat Pump 8.50 HSPF Split Heat Pump 17.0 SEER Setback New
HVAC DISTRIBUTION Duct
Location- Heating Cooling Duct Location.,.... .R-Value.:..Status , ..
2 T Ducted Ducted Attic, Ceiling Ins, vented 8.0 New
WATER HEATING
Ot . Type Gallons Min. Eff . Distribution Status , ...
Ene Pro 5.1 b Energ'Soft_ UserNumber.,.8165 .''RunCodec 2015-b1,13T11r33;27 __ , .JD: 63276. ":.. ,. .Pa e.d of 14.
PERFORMANCE.;CERTIFICATE Residential ., .:: (Part 2 of 5)
Project Name
Andalusia Plan 22-C
Building Type ® Single Family ❑ Addition`Alone
❑ Multi Family ❑ Existing+ Addition/Alteration.
Date
111312015
SPECIAL FEATURES INSPECTION .-CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special iustification,.anddocumentation.submitted..;_...;;::.,=:
Compliance for all orientations is specified see`section 151 (6)'2 of tha Standards and section 7:6.2 of the Residential Compliance"Manual.
The Roof R-30 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater., The..inspe'ctor must receive .
completed CF-4R. form. for.each.of the measures listed below for final to be. iven,.
The Cooling System 4 T includes credit for a 12.5 EER Condenser A certified HERS rater must field veiify'the installation of the correct "Condenses.
The HVAC System 4 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cf n.
Compliance credit for quality installation of insulation, has beenused. HERS field verification is required.
The HVAC System 4 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 4 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
The Cooling System 4 T includes credit for a 12.5 EER Condenser. A certified HERS rater must Field verify the installation of the correct Condenser.
The HVAC System 4 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 4 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 4 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
The Cooling System 2 T includes'credit for a 13:0 EER Condenser. A certified HERS rater must Field verify the installation of the correct Condenser.
The HVAC System 2 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
EnergyPro. 5.1 by Eherpyqbft User Number.` S165 ., ;`:RunCode: Z015 1-13T11i53:27 ,.. aD. 63276 -: Pa e 5 of 14_
PERFORMANCE CERTIFICATE:.".Reside il; :.;,w .. (Part 2 of 5: CF-1 R
Project Name
Andalusia Plan 22-C .-
Building Type ® Single -Family` 't7 Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
bate
111312015
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the s ecial "ustification and. documentation,submitted..•
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified. HERS Rater. The inspector must. receive a
listed inal,.e.vcompleted CF-4Rformfor each:ofthe me suresen: :....
Compliance credit for quality installation of insulation has been used. HERS field verification'fs equired.
The HVAC System 2 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 2 T incorporates HERS verified Duct Leakage. HERS field verification and diagnos'tic'testing is required to verify that duct leakage
meets the specified criteria.
The Cooling System 2 T includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 2 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/c/m.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 2 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically mea' ure'airflow of the HVAC System.
The HVAC System 2 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
EnergyPro 5.1 by Ene Soft User Number°AY65 .T.-`Run.Code: 2015-01-13T11:53:27 ::ID: 63276. :' ''" .. Pa e 6 of 14
PERFORMANCE.CERTIFICATE ,Residential_ :(Part, 3 of 5) Cf-1 R ;_
Project Name
Building Type 0 Single Family "ij Addition Alone
Date
Andalusia Plan 22-C
❑ Multi Family ❑ Existing+ Addition/Alteration.
1111312015
ANNUAL ENERGY USE SUMMARY.,:,,:.
Standard Facing - " "'Margin Facing ' ' Margin ` Facing Margin Facing 'Margin
TDV kBtu/ft2- r North East South West
Space Heating 4.92 4.50 0.42 4.56 0.36 3.61 1.31 4.05 0.87
Space Cooling 55.80 39.25 16.55 39.79 16.01 39.76 16.05 40.14 15.66
Fans 11.02 10.23 0.79 10.37 0.65 10.38 0.64 10.45 0.57
Domestic Hot Water 9•54 12.66 -3.12 12.66 -3.12 12.66 -3.12 12.66 -3.12
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Totals 81.29 66.65 14.64 67.39 13.90 66.41 14.88 67.30 13.98
Percent Better Thon.Standard:. 18.0 % 17.1 % 17.2%.
BUILDING COMPLIES - .HERS VERIF.ICATIOV REQUIRED ``.
Fenestration
Building Front Orientation: An Four'Or►entations Ext. Walls/Roof Wall Area Area .
Number of Dwelling Units: 1.00 (N) 1,485 201
Fuel Available at Site: Natural Gas (E) 360 165
Raised Floor Area: 0 (S) 980 157
Slab on Grade Area: 0 (►M 776 366
Average Ceiling Height: 12.0 Roof 3,465 0
Fenestration Average U-Factor: 0.31 -TOTAL: 889
Average SHGC:. _,0.25 Fenestration/CF,A Ratio: 24.7.%.
REMARKS .. _ . :.....
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company GMEP Engineers
1/13/2015
Address 4400 Campus Drive Name Gangyi Zhou
City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications",. and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Pekarek-Crandell,lnc
Address 31411 Camino Capistrano Name
City/State/Zip San Juan Capistrano, CA 92675 Phone 949.487.2320 Signed License # Date
EnemvPro 5.1 by Ene Soft . Usei'Numtier.• 8165 .RunCode: 2015=01-13T11s53:27
CERTIFICATE OF,,COMPLIAN.CE Re ident,la .: ;,(Part 4 O.,f.,5) ...::. CF-1 R .
Project Name
Andalusia Plan 22-C `
Building Type `® Single Family `0 Addition Alone
. ❑ Multi Family ❑ Existing+ Addition/Alteration. ,
Date
1/93/2015�
OPAQUE SURFACE
DETAILS
Surface
T e
Area
U-
Factor
Insulation
Azm
Tilt
Status.
Joint Appendix'
4.
Location/Comments
Cavity
.
Exterior
Frame
Interior
Frame'
Wall
399
0.057
R-19
4.0
None
0
90
New
4.3.1-A5
Great RoomlKitchen/Ent
Wall
155
0.057
R-19
4.0
None
90
90
New
4.3.1-A5
Great RoomlKitchenlEntry
Wall
107
0.057
R-19
4.0
None.
270
90
New
4.3.1-A5
Great Room/Kitchen/Ent.
Wall
721
0.057
R-19
14.0 '
None'
1
1801
90
1 New
4..3.1-A5
Great Room/Kitchen/Ent,
Roof
1,100
0.031
R-30
0
0 New
4.2.1-A20
Great Room/Kitchen/Ent
Wall
401
0.057
R-19
4.0
None
0
90
New
4.3.1-A5
Master Suite0r.SuitelLau
Wall
40
0.057
R-19
4.0
None'
90
90
New
4.3.1-A5 • '
Master.Suite/Jr,SuiterLaui
Wall
94
0.057
R-19
4.0
None
270
90
New -:4.3.
I-A5.
Master Suite/Jr Suite/Lai ',
Wall
752
0.057
R-19
4.0
None
160
• '`90
New .`
.4:3.!:M
M6sterSuite11 Sui161Ladr
Roof
1,541,
0.031
R-30
_
'0
New
4.2.1-A20
Master_Sufte/Ji Suite/Lau
Wall
293
0.057
R-19
4:0
None.'
90
New. _'.
4:3.1-A5
Office Bedroom
Wall
.143
0.057
R-19
4.0
None
5270
90
New
4.3.1-A5 =.••
Office BedrobM.Roof
380
0.031
R-30
0 New
4.2.1-A20
Office Bedroom"Wall
192
0.057
R-19
4.0
None
90
New
4.3.1-A5
Casita
Wall
66
0.057
R-19
4.0
None`
.
270
90
New • .
4.3..1-A5 '.
Casita
Roof
444
0.031
R-30
_..
0
D• New : , ;.
4r2.1-A20
Casita". "
FENESTRATION
SURFACE
DETAILS _ .
ID
Type
Area
U-Factor
::SHGC
Azm"
Status
, Glazin T e
:Lflcatwn/Comm nts
1
Window
4.0
0.300
NFRC
.0.20
NFRC .:
0
New Fixed
Glass. -:
Great Room%Kitchen/Entry/Mo
2
Window
4.0
0.300
NFRC
0.20
NFRC ..
0
New. _ Fixed,
Glass ;. t ;'.
Great Room/Kitchen/EntrylMo _
3
Window
6.0
0.300
NFRC
.0.20
NFRC
: 0
New Fixed
Glass ,fi 1:
Great RoomlKitche'rVEn IMo:
4
Window
37.0
0.300
NFRC
0:17
NFRC
':'V
New . "; ::FG.IlV11TER;
-°
Gieat:Room/Kitchen/Entry1Mo
5
Window
15.0
0.300
NFRC
0.17
NFRC
;0
Now'._-,: Single
Hung
Great RoomlKitchen7Entry/Nto.
6
Window
96.0
0.320
NFRC
0.30
NFRC
:,',90
New :,. , ; Sliding
Gl&s Door, -
Great Rooril/iV f chenjEntry/Mo'
7
Window
33.8
0.300
NFRC
0.17
NFRC
90
New fG/MITER
Great Room/Kitchen/,Ent. %Mo'
' 8
Window
30.3
0.320
NFRC
0.36
NFRC
r '90
New Fien&h
Glass Door
Great, Roorri%KitcheNEntry/IV1o,
9
Window
4.5
0.380
NFRC
0.35
NFRC, ..
.'90
New ..: ; 'RndFixed
,
Great f?oomlKitc_henlEntry7Mo:
10
IMndow
192.0
0.320
NFRC
0.30
NFRC
270
New' ', Sliding
G/ass:Door : :Great
RoorNKifchenlEntrydhilo ,
11
Window
56.4
0.320
NFRC
,,0.30
1 NFRC . ,
:. _.270
New Fixed_
Glass, 0.32/0.3
Great Roomfl6tchenlEntry/M6i
12
Window
48.0
0.320
NFRC
�0.30,
NFRC
480
New Sliding
Glass'Door
Great Room/KitchenlEntry/llifo`,
13
Window
16.5
.0.300
NFRC
U:17
NFRC. ".
D
New . ; Casement'
_..; A
Master ;Suite/J� Suitekaundr
14
Window
48.0
0.320
NFRC
..0,36
NFRC,
;'O.
New :` Sliding
Glass Door „
Master'Suite%Jr Suite/Laundry':
15
Window
96.0
0.320
NFRC
0;30
NFRC ..;
:, 270
New , Sliding
Glass. Door a
-Master Smte%J `SuitelLaun ry_ ,
16
Window
11:0
0.300
NFRC
0.17
NFRC
180
New . Casement
•
,Master Suite/Jr Suitdkboery',
(1) U-Factor Type: 116-A = Default Table from Standards,`NFRO
2 SHGC Type: 1 16-B.,=,Default Table from Standards, NFRC
=.Labeled'Vafue'.•:..M1
= Labeled Value
EXTERIOR
SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
' '-'Overhan
"Left Fin
Ri ht Fin.
H t
Wd
Len
H t
LExt,
REA
Dist
Len
H t
Dist
Len
H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4 _
Bug Screen
0.76
a
5
Bug Screen
0.76
6
Bug Screen
0.76
8.0
10.0
10.0
0.1
2.0
2.0
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
10.0
16.0
10.0
0.1
2.0
2.0
.
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15 jBug
Screen
0.76
8.0
72.0
8.0
0.1
2.0
2.0
16 jBug
Screen
0.76
Ene Pro5.1 b Ene Soft ' .User"Number'. 8165 . - ,' RunCode: 701.5-01-13T11;53:27 • .'' AD: 63276 ;:: ; • Pa e 8 of 17
CERTIFICAT�*OF'COMPLIANOE:'**"' artA. f5 71 R':�
Project Name
Andalusia Plan 22-C
Building Type 0 Single Family* 0 Additiori'Alond
DIVIultiFamily 'D,Existing+Addition//�lteration
312015.
OPAQUE SURFACE.,I)ET410-
Surface
Type
Area
U-
Factor
Insulation
Azm
Tilt
Status..
Joint Appendii
4
Location/Comments
Cavity.
Exterior
Frame
Interior
Frame
-jr
I
FENESTRATIONSURFACE
DETAILS
ID
Type
Area
U-Factor'
14GC2
Status--].'�
laziriglype
6 cati6h1C16ffiffi7n1s
17
Window
11.0
0.300
NFRC
0.17
NFRC
180
New Casement
Master Suitc�14r sqitb1L?undry
18
Window
16.5
0.300
NFRC
0.17
NFRC
186
New Ciis
.�.J,.
Master SuitelJr Suitekaundry
19
Window
16.5
0.300
NFRC
0.17
NFRC'
180
New- Casemeqt.'
Master Suite1ji Suiteka4ndry
20
Krindow
16.5
0.300
NFRC
0.17
NFRC
180
New Casement
Master SuitelJr SuitelLa n
V dry
21
Window
10.0
0.300,NFRC
0.17
NFRC
180
New Casement
Master 4L?itelJr SuitelLaufidr
,y
22
Window
4.5
0.300
NFRC
0.17
NFRC
180
New Casem
9 nt
Master SuitelJr SuitelLaun
23
Window
4.5
0.300
NFRC
0.17
NFRC
-186
New Casement
Master Suitelir loitekdu�dr
24
Window
4.5
0.300
NFRC-
0.17
NFRC
1.80
NeYV '.Cas
Tn-dr-v-
Master SuitblJr S�itekaun fy
25
Window
4.5
0.300
NFRC
0.17
NFRC
'.180
New 'Cas-em
n
ii �aW'�4 SuitekiLinqily
26
Window
4.5
0.300
NFRC
0.17
NFRC*.
186
New Casemqfir
Master S&HPZ
.27
Window
4.5
0.300
NFRC
0.17
NFRP,.
1,80
Ne w Caseme'ht
un
Mast6rtuite1JrStiiteZLa tt�
28
Window
4.5
0.300
NFRC
0.17
NFRC
0
New Casement
Office Bedroom"
29
Window
27.5
0.300
NFRC
0.17
NFPC
.6
New Casement
ofrice Be&obm
30
Krindow
11.0
0.300
NFRC
V. 17
NFRC
270
Wew Casement
Office Bedroom
31
Window
11.0
0.300
NFRC
0. 17
NFRC
270
New Casemeht
Office Bedroom
32
1 Window
.11.0
0.300
NFRC
, 0. 17.
NFRC
0
New Casement
Cagita
(1) U-Factor Type: 11 6-A = Default Table from Standards; NFIRC Uibel,A V61�6,4.
e . d*
(2) SHGC Type: , 1107,13 F= Petf ault Table f rorn Standards, NFFIC L4061 V
allu"
e
EXTERIOR
SHADINADETAILS.
ib
� Exterior Shade Type
SHGC
Win oii
Overhang ' .."-4 -j'..:j
.. ft
te Fin
n
Hqt-
Wd
Len
H-qt
I-Ext
-REkt
'Dist
-Leri,
--Hg t'.'
Dist j
Len, .
Hgt'
17
jBug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23 jBug
Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29 jBug
Screen
0.76
30
Bug Screen
-T-
0.76
-0.76
31 IBug
Screen
32 jBug
Screen 1
0.76
EnergyPro 5.1 by EnprgySoft Uspi Numbei.�,8165.... -27 --6321,6 P 09 of 14
. RtinCode: 20541 Tll:��3.' 10�
• - I •
Project Name
Andalusia Plan 22-C
Building Type 0 Single Family-13 Addition A .,one
0 Multi Family 0 Existing+ Addition/Alteration
.. - ••
oint Appendix
4
Location/Comments
-S�Q"4CE
DETAILS_
to]-
:.R6a, CF-1 RCERTIFICATE OFCOMPLANCEsi
Project Name
Andalusia Plan 22-C .
Building Type 0 Single Family ❑ Addition Alone"
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
.1-11312015
BUILDING ZONE_INFO.RMATION
System Name
Zone Name
Floor Area
Volume
Year Built
New
Existing
Altered
Removed
4 T
Great Room, Entry, Kitchen, Wet
1,273
17,949
4 T
Master Suite, Master Bath, ASu'
1,541
16,951
2 T
Office Bedroom
341
3,751
2 T
Casita
444
4,484
Totals
;3,5991
01
01
0
HVAC SYSTEMS .
System Name
Qty.
` Heatiri' Type-
Min'. Eff..
Coding Type
`Min..Eff.. '
`Thermostat T e
Status'
4 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER Setback
New
4 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
.15.0 SEER Setback
New
2 T
1
Split Heat Pump
8.50 HSPF .Split
Heat Pump ...
17.0 SEER Setback
New
2 T
1
S lit Heat Pump
8.50 HSPF
Split Heat Pump
17.0 SEER Setback„
. „
New
HVAC DISTRIBUTION
System Name
Heating
Conlin
Duct Location
Duct
R-Value
Ducts
Tested?
Status
4 T
Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
0-
New
4 T
Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
0
New
2 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
0
New
2 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
M
New
13
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
2
Small Gas
Kitchen Pipe Ins
40,000
50
0.58
n/a
Ma
New
MULTI -FAMILY WATER
HEATING.
OETAILS.
HYORONIC
HEATING
SYSTEM
PIPING.
Control
Hot Water Piping Length
ft
0
0
io
v
a —
System Name
Pipe
Len th
Pipe
Diameter
Insul.
Thick.
at .
HP
Plenum
Outside
Buried
01
13
EnergyPro 5.1 by- EneSoft User Number. 8.165 , .. Run Code: 2015-01.=13T1153r27 JD: 63276 . ....: • ' .. ` :. ':";.:Pa a 11 of 14'
MANDATORY MEASURES,SUMMARY. Residen#la1 Pa e 1 of, 3 < .:.-.: MF-1 R.
Project Name
Andalusia Plan 22-C,
Date
111312015
NOTE: Low-rise residential buildings subject to;the Standards musicomply with all applicable mandatory' measures listed; regardless of ,
the compliance approach used. More stringent energy measures listed on the Certificate: of Compliance •(CF-1 R,.CF-1 R-ADD; or CF
1 R-ALT Form) shall supersede the items marked with an asterisk.(') below. This Mandatory Mea"surer Summary shall be incorporated.
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of.the MF-1 R
Form with plans.
Building Envelope Measures
116 a 1: Doors and windows.between conditioned and unconditioned s aces'are manufactured to limit'air'leaka e
§116(a)4: Fenestration producfs (except field -fabricated windows) have a.label listing the certrfied U-Facfor, certified Solar. Heat Gain
Coefficient SHGC , and infiltration that meets the re uiremen'ts of; 10.111(a).�'.: _•
117: Exterior doors and windows are. weather-stri ed; all 'oints.and ene3rations are caulked and. sealed..
118 a : Insulations ecified or installed.meets 5tandards.forIIns ulatm0 AllAter ial. lndicate.f a and.ir c. de"on CF-6R Form .
§118(i): The thermal em'ittance'and solar retlectan6e Values bf the coot roofing.material meets the`-require'rents of: §118(i) 1164 'the
installation of a Cool Roof is specified on the. CF-1 R. Form.
'§150 a : Minimum R-19 _insulation in wood -frame ceiling or e,_ uivalent:U,-factor.
150 b : Loose fill insulation shall conform with.manufacturer's installed:desl n labeled R-Value:
" 150 c : Minimum R-.13 insulation in, wood -frame wall or e4uivalent U factor
'§150 d : Minimum R-13 insulation in. raised wood -frame filoor or` urvalent U_ factor .•" >
150 f : Air retarding wrap is tested, labeled, and installed accordin to ASTM,E1'677-95 2000 when s .ecified on:the CF-.1.R`Form
150 : Mandatory Vapor barrier installed.in Climate2ones 1;4 or,16.
§150(I): Water absorption rate for slab edge insulation material atone without facings is no greaterYhan 0.3°�;;vuater vaPor:permeance '
rate is'no greater than 2.0 erm/jnch,an.d shall be, rotected`frdrh 01hysicAl dama e'and. UV. G ht deterioration
Fire laces, Decoratty..e Gas' . 1iarlces and Gas Lo4 Measures; •... •.
T
1 e 1 A: Mason or facto, -built fire laces have 'a closable metal or `lass door coverin the entire o 'enin of the firebox
§150(e)1 B: Masonry or factory-builf fireplaces have'a combustion outside air intake, which is at least six square inches In area aria is
.: "
equipped with a with,a readilyaccessible, _ erable, and t' ht fittin` darn er rand or;a.combustion-air control device:
§150(e)2: Continuous burning plloflights and the use"of indoor air for cooling a firebox jacket when that indoor arris vented to the
outside of the building, are: rohibited. -
Space Conditionin ;Water Heatin' arnd'Plumb n 'S stem Measures: J .
§110-§113: HVAC equipment,'water'heaters-, showerheads,'faucets and all other regulated appliances are certified by the'Energy'
Commission. '
§113(c)5: Water heating recirculation loops'serving multiple dwelling units antl High -Rise resident, I occupancies'meet the`air release
valve, backflow prevention, pump jsolation,valye.; and, recirculationn-loo re. 'uirements.Af..11.3(C)5-
C."..connection
§115: Continuously burning pilot fights are`prohibited'for natural gas.: fan=type central furnaces household' 6Xing appliances .•:.
(appliances with an electrical supply voltage connection with pilot Iighis chat consume lessthari 1'50 Btu/hr are exempt), and pool and
spa heaters.
150 h : Heating and/or cooling loads are calculated in accordance with,ASHRAE, SMACNA or ACCA. ....:. ., , .
150 i : Heating systems are equipped ed with thermostats that meet the,setback,re uirements of:Section 1,12 c ,
§1500)l A: Storage gas water heaters rated with an Eri fty; Factor no greater than the federal minimal sfandard are externally wrapped
with insulation havingan installed, thermal resistance of 'R-12,or reate'. '
§1500)1 B: Unfired storage tanks, such as 'storage`tAHks or Backup tanks for solar water heating system >5r other ,indirecf hot water .
tanks have R-12 external insulation or R-.16 internal insulation where'the internal insulation R-value is indicated on "the exterior"bf the
tank.
§1506)2: First 5 feet of hot and cold water pipes closest to_water heater, tank,, non -recirculating systems, and entire length of ,
recirculatingsections of hot water pipes are insulated_ er:Standards'. 6:1. 0 B.
§1500)2: Cooling system piping (suction, chilled water -or 'brine lrnes) and piping insulated betW6 rfheating'source and indirect hot`
water tank shall be insulated..to Table 1504and.. nation 1,50-A.'. .
§1500)2: Pipe insulation for steam hydronic heating'systems of hot water systems 515 psi, meet's the requirements of Standards Table
123-A.
150 ' 3A: Insulation is protected from dama e, including that due.to sunlight, moisture, a ui ment maintenance, and wind. + '
§1500)3A: Insulation for chilled water piping and r'efrigeraht suction lines' ihdludes a `vapor retardant or is enclosed entirely in
conditioned space.
150 ' 4: Solar water -heating systems and/or collectors are.certified by the Solar Rating and Certification Corporation. r
EnergyPro5.1 by EnergySoft . User Number..•,81 §5 . •; . RunCode:.2015-01-13T11 53:27 , ;..- ID,: 63276 • , Page 12 of 14
,.S
MANDATORY MEASURES SUMMARY Residential, =' ` Pa `e 2 of 3 MF-1 R .
Project Name - • - - - • •
Date F'
Andalusia Plan 22-C
1/13/2015
§150(m)l : All air -distribution system.'ducts and plenums installed, are sealed and insulated. to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5'; supply -air and return air ducts and plenums are;msulated to"a minimum Installed level of
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic; tape or other duct -closure system that meets ahe
applicable requirements of UL 181, UL 181 A, or IJL 181 B or aerosol. sealant that meets the requirements'of hL 723, If mastic or tape is ,
used to seal openings greater than 1/4.:inch, the corn tition.of mastic an'd either mesh or`ta a shall be,.used
§150(m)l : Building cavities, support platforms for air handlers and plenums defined or constructed with materials other than seated
sheet metal, duct board or flexible duct shall.not be.used fbr'666veying66nditioned .air Bu`ildmg ca�nties and support platforms may
contain ducts.,Ducts installed in cavities and support platforms shall not be compressed to'cause re* Uttions in the;cross-sectional areii
a ;.
of the ducts.
§150(m)2D: Joints and seams'of duct systems and their components shall not be sealed with clothback ri bber�adhesive duct tapes
unless such tape is used in comat binion, with`mastic:anti draw`barids.
150 m 7: Exhaust fan. systems have back draft or.automatic dam ers * i
§150(m)8: Gravity ventilating`systems serving conditioned space have eith`eF automatic or`readily accessible, manually operated'`
dam rs.
§150(m)9: Insulation shall be protected from. damage including that due to sunlig1ht,. moisture equipment maintenance and wend.-; ;
Cellular foam insulation shall be protected as above or painted w thA coating that is weter. retardant and provtdes`shieltlingfrom solar
radiation that can cause de radation of the tn'ate"'— I '
150 m 10: Flexible ducts cannot have.porous inner cores. '
§150(o): All dwelling units shall meet the'requieements of ANSI/ASHR"AE Standard. 62 2-2007. Ventilation'and.Accgptable`lndoor
Quality in Low -Rise Residential Buildings. Window operatonis not a�permissibte method providi"ng_the`Whole.Building Ventilation
required in Section 4 of that Standard.:: .
Pool and Spa Heatm S `stems and,E ui merit Measures:-
§114(a): Any pool or spahe'ating "system shall be certified to have a thermal efficiency that complies with: the Appliance'Effidency
Regulations; an on -off switch mounte'ti outside of the heater;"a permanent weathe[proof:plate or card. with operatingrinstrucbons; and
shall not use electric resistance, heatin or.a:. clot li lit., `
§114(b)l : Any pool or spa heating64dipmentshallbe installed with at least 36 o'f.pipe between'filter and.heatef, or fedicated suction
and return lines, or built-up connections for' Vture'solar.heating.
114 b 2: Outdoor pools ors as that have a .heat.purr)p o.r. as heater shall have a:cover..
§114(b)3: Pools shallhave" directional mlets'that adequately mix the pool'water and'a time twitch'that will allow all pump§ to be set_or,"'
..
programmed to run only during- off-peak electric'demantl, eriads:::.:' .. .
150 : Residential,pool systems or.e 'uiO merit meet the: um siziri ,flow rate, i in filter and valve re uirerrients of 1'50
Residential l,i htin Measures.'
§150(k)l : High -efficacy luminaires or LED Light Engine with Integral :Heft Sink has'an efficacy that is no lower thah'the efficacies"
contained in Table 150-C and is not a. low, efficac Iuminaire as s edfied b 150 (k)2.=
150 k 3: The watta e'of permanently installed urninaireS'shall.le`determ'ined a"s`S 'eclfied.b 130 d .
§150(k)4: Ballasts for fluorescent lamps rated t3 Watts or greater shall be'electronic and`shall have an outputfrequency rid less than t
'
20 kHz.
§150(k)5: Permanently installed night.lights and. night lights :integral to a permanently installed lurriinaire Qr exhaust fan shall .contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain aline -voltage socket`orline- .
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicabje re quiremeritt.of 150 k .
150 k 7: All switching devices, and controls shall meet the require . meritsof. 150(k)7.
§150(k)8: A minimum of 50 percent of the''total rated. wattage`of permanently installed lighting m kitchens shall be.high.efficapy.
EXCEPTION: Up to 50 watts for dwelling units less tFian or equal to. 2,500 ft2or 1,00 watts -for dwelling units largerthan 2,500 ft2may be
exempt from the 50% high efficacy requirement when: all low_ efficacy luminaires m; the kitchen are'controlled by a rbanuaton occupant
sensor, dimmer, energy management systeni•(EMCS), or'a multi -scene' programmable control system;ii:and,. all_permanerii(y installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are hig�I efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting'that`is'internal`to cabinets shall use no more'than20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoR Vspf tpbet j .165 ." Run�ode:'2015-Q1-13T11.53:27 ID: 63216. , '.• t', ` ;`rage 13.of 14,
MANDATORY MEASU.RES.'SI�MMARY: Resrd;ential ;: °.: P'a"e 3 of 3 MF-1 R.
Project Name
Date
Andalusia Plan 22-C
111312015
§150(k)10: Permanently installed luminaires in'bathroom§,'attached and detached garages, lab nd ri rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor...
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms„garage s, laundry rooms,,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable regwrem"ei nts of §119, or by a manual ,
r
on occupant sensor that complies with the applicable requireents of,4119. EXCEPTION 2 1_ighting m:detached storage building less
than 1000 square feet located on.a residential site is. not. required to .com I 'with: 150 k 11
§150(k)12: Luminaires recessed into insulated ceilingssshall be listed for zero clearance insulation,contact`(IC) byUnderwriters .
Laboratories or other nationally recognized testing/rating laboratory; and have a.label that certmes,the lumiunaire is airtigFit with,a",,
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket'or-caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private'patios."in.low=rise'residential buildings with four or,rnore;
dwelling units, entrances, balconies, and porches, which are.perrrianentI' mounted.to a residential building or to other bulldmgs:on the_.
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall 1,e allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the m.otion;sen.sor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; Oka energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2:.Outdoor
luminaires used to comply with Exceptions to §150(k)13 maybe controlled by a temporary override switch Which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3:. Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address.signs shall comply wit6.Section 148;.OR not contain a screw -base socket, and consume.no
more than five watts of power as.determined according to 13() d ..
§150(k)15: Lighting for parking lots and carports witha`total of for 8 or more vefiicles per site shall comply with'the applicable,,
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vetiicfes shall comply with the applicable
re uirements of Sections 130,.131, 134, and 146.
§150(k)16: Permanently installed lighting in the:enclosed, non dwelling spaces`of low-nse`tesidential buildings w'ith:four or more: . ;. .
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed,promed
that they are controlled by an occupant sensors certified to comply with theApplicable requirements of 119. .
EnergyPro 5.1 by EnergySoR . User Number.• 0165,, ;OunCode: 2015-01-1 T11 53:27 , ,, ID`.63276 _ ; ,: Page 14 of 44.
31
BUILDING ENERGY ANALYSIS.R.EPORT
PROJECT:
Andalusia Plan 23A
RICEIVED Coral Mountains 75' Lots
La Quinta,, CA
!BAR 31 2015
OFaAQUINTA Project Designer:
COMMUNrl Y ®EVELOPMUff
Pekarek-Crandell,lnc
- 31411 Camino Capistrano
San Juan Capistrano, CA 92675
�949.487.2320
Report Prepared by:
Gangyi Zhou
GMEP.Engineers —
4400 Campus Drive
Newport Beach, CA'92660 r'
9497521612
{
- - CI��OF LA QUINTA
BUILDING & SAFETY DEPT.
APT ��®
FOR CONST UCTION
. Job Number: pad
63276
Date:
r
1/21/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC—www.energysoft.com. `
Energ Pro 5.1 by EnergySoft User'INumber-8165. .., ,'... RunC,ode: 2015-Of=21T17 16:U3
rl
PERFORIVIANQE"CEIRTIPICATE: "AesId'en'tia'I ..(Part 1..of 5)
CF-1 R
Project Name
Andalusia Plan 23A
Building Type 0 Single Family 0 Addition Alone
13 Multi Family 0 Existing+ Addition/Alteration
Date
112112015
Project Address
Coral Mountains 75'L.ots , La Qqinta
California Energy Climate Zone
jCA Climate Zone 15,-,
Total Cond. Floor Area
3,612
Addition
n1a
#of Stories
FIELD INSPtCTI0WENeAdYCHE0K-LI8T
El Yes 0 No HERS Measures If Yes, A CF-4R must be provided per Part.2 of 5 of this form.
El Yes 0 No Special Features If Yes, see Part 2 of 5 of. this,form:f.or,.details.
INSULATION
Construction,
Area 'Special
(ft)
Cavity Fpaturp� (seefart 2 of 5)-
$1atUS
Wall Wood Framed
R-19 Z 990 Ext=R-4. 0
New
Slab Unheated Slab -on -Grade
None -3,612 Perim = 430'
New
Roof WbodFramedAttic
R-30 4,619 Radiant Barrier
New
FENESTRATION U- Exterior
Orientation Areg(ft).... Factor.., -$HGC -_..Overho -ng Sidefins,,Shc e
-.Status
Front (N) 41.0 0.300
0.17 none none Bug Screen
New
Front (N) 27.5 0.300
0.17 12.0 none Bug Screen
New
Front (N) 17.5 0.300
0.17 none none Bug Screen
New
�eft (E) 144.0 0.320
0.30 12.0 none Bug Screen
New
Left (E) 30.3 0.320
0.30 2.6 none Bug Screen
New
Right (IM 192.0 0.320
0.30 15.0 none Bug Screen
New
'Right (tM 38.5 0.300
0.17 9.0 none Bug Screen
New
Rear (S) 16.5 0.300
0.17 none none Bug Screen
New
Rear (S) 85.5 0.300
0.17 none none Bug Screen
New
Right (W 24.0 0.320
0.30 9.0 none Bug Screen
New
Right (VL9 57.0 0.300
0.17 1.0 none Bug Screen
New
HVAC SYSTEMS
Oty. Heating, Min. Eff
Cooling Min. Eff .,.Thermp4.tat._.,Status
I Split Heat Pump 8. 50 HSPF
Split Heat Pump 15. 0 SEER Setback
New
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback
New
I Split Heat Pump 8.50 HSPF
Split Heat Pump 17.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Poolling
3 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
2.5 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
2 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
WATER HEATING
Oty. Type Gallons Min. E�ff.. pistril�utjqn
Status,
2 Small Gas 50
0.58 Ifthen Pipe Ins
New
EnergyPro 5. 1 by EnergySoft User Number..M.5 �,:!Ru�C6di,.2015-01-21T!7:16:03 61276
-Page 3 of 15
PERFORMANC8'.)OtRTIPI-C-AT.P-.�:.,fieside*nt� I (Part 1'
-CF-1.13
Project Name
Andalusia Plan 23A
Building Type 0 Single Family 0 Additioh None'
11 Multi Family 0 Existing+ Addition/Alteration
Date
112112015
Project Address
Coral Mountains 75'Lots La Quinta',_,,
California Energy Climate Zone
CA Climate Zone,15
Total Cond. Floor Area
3,61,
Addition
n1a
#of Stories
I
FIELD INSPPECT-10KEWERGY C8'I5CXLI8T
El Yes 0 No HERS Measures If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
IZI Yes 0 No Special Features If..Yes, see Part 2 of 5 of this form f9r.details,
INSULAT15-�"
Construction Type
Area Spec . ial
Cavity (fl') Features.,(.sqq.Pprt.2 pf.5) ,Status....
FENESTRATION U- Exterior
Orientation Area(ft) Faptor. .$,HG C n Status .
Oyerlhla Sidefin�;,_Shades,
Left (E) 33.0 0.300
0.1� none none Bug Screen New
Front (N) 40.5 0.300
0.17 none none Bug Screen New
Front (N) 120.0 0.320
0.30 none none Bug Screen New
Left (E) 27.5 0.300
0.17 none none Bug Screen New
Rear (S) 24.0 0.320
0.30 4.0 none Bug Screen New
Right (Vtq 72.0 0.320
0.30 none none Bug Screen New
HVAC SYSTEMS
Oty. Heating Min. Eff
Cooling M in. Eff TherMqstpt.. Status,
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback New
I Split Heat Pump 8. 50 HSPF
Split Heat Pump 17.0 SEER Setback New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location..... R-YAlue .,Status.,,
3 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0 New
2 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0 New
WATER HEATING
Oty. Type Gallonp.. --.01171, Eff ...,,JPirA0bVt1QP. Status
EnergyPrD 5. 1 by EnbrgySdff VS6ePJurrib6r'-8-!,0,
',"RuhPodi: 70t5-0,t�4fTl, :1 -3. 27
7 60 ID 6� 6.�_
Page 4 of 15 -1
PERFORMANCE CEaTIFICATE Residential ,..(Part 2 of 5�. _ CF-1 R
Project Name
Andalusia Plan 23A
Building Type 0 Single Family 0 Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
112112015
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special 'ustification.and,documentation submitted.. :..,..:.
Compliance for all orientations is specified,' see section 151 (6) 2 of the Standards and section 7.6.2 of the Residential "Compliance °Manual.
The Roof R-30 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix RA4.2.2.
HERS REQUIRED VERIFICATION"
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF749..form.for.eaO,of.the measures listed. belpw,for,final.to bp.given,.
The Cooling System 3 T include§ credit for a ' 12.5 EER Condenser: A ceifified HERS rate`- rnustfield verify the installation of thb correct Condenser
The HVAC System 3 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 3 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 3 T incorporates HERS verified Duct Leakage. HERS field verification and diaghostic testing is`eequired to -verify that duct leakage
meets the specified criteria.
The Cooling System 2.5 T includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 2.5 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 2.5 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically ineasuie airflow of the HVAC System.
The HVAC System 2.5 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify`that duct
leakage meets the specified criteria.
The Cooling System 2 T includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 2 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
EnergyPro 5.1. by EnergySoft Use- Nuinber'8165..'..,'::Reindode:.201S-6.1-21T17r18:03 1&.' 63276 Page 5 of 15
PERFORMANCE:CERTIFICATE. Residential(Part 2 of.5)... CF-1 R
Project Name
Andalusia Plan 23A„
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
112112015
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted. .
HERS REQUIRED VERIFICATION "
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R,.form;for each>of the.measures;listed below for final_to be, iven. :.
Compliance credit for quality installatiori'of insulation iias.been used HERS field verifrcahon 1s required
The HVAC System 2 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 2 T incorporates HERS verified Duct Leakage HERS field verification and diagnostic testing is required to' verify that duct leakage
meets the specified criteria..
The Cooling System 3 T includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 3 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm..
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 3 T includes credit for verified adequate. airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 3 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required'to verify that duct leakage
meets the specified criteria.
The Cooling System 2 T includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 2 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation tias been used.'* HERS field verification is'required. '
The HVAC System 2 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure ailflow'of the HVAC System.
Ene Pro 5.1 by Ene Soft : Llser Number. 6165 'RunCode '2015=01=21 T17:16:03 `'V: 63276 : "; :.: Pa e 6 of 16 .
PERFORMANCE. CERTIFICATE.:. ,Residential (Part 2 of 5) CF-1 R .
Project Name
Andalusia Plan 23A
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
112112015
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and .documentation submitted.... ;.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form, for each_of.the measures.listed.below for final..to be;, iven. .. :...:............. . ..:
The HVAC System 2 T incorporates HERS verified Duct Leakage:' HERS field verification and diagnostic testing rsYequired to verify that ductYeakage
meets the specked criteria.
Ene Pro 5.1 b Ene Soft UserNumber..8165 Runcode: loin-61-21T1.7:16::63.. '10: 63276" Pa e'7 of 15 .
PERFORMANCE;.CERTIFICATE .:, Residential.. (Part.3 of 5) CF-1R.
Project Name
Building Type m Single Family E Addition Alone
Date
Andalusia Plan 23A
❑ Multi Family ❑ Existing+ Addition/Alteration
1112112015
ANNUAL ENERGY.0E SUMMARY...:.:
Standard Facing Margin Facing " 'Margin 'Facing Margin Facing" Margin
TDV kBtu/ft2- r North East South West
Space Heating 4.58 4.43 0.14 4.20 0.38 3.44 1.14 4.20 0.38
Space Cooling 56.64 40.78 15.86 41.37 15.28 41.55 15.09 42.02 14.62
Fans 11.40 10.92 0.48 11.06 0.34 11.12 0.28 11.21 0.19
Domestic Hot Water 10.10 12.91 -2.81 12.91 -2.81 12.91 -2.81 12.91 -2.81
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Totals 82.72 69.04 13.67 69.53 13.19 69.01 13.71 70.33 12.39
Percent Better.Than Standard: 16.5 %, ., ,15.9 % 15.0
BUILDING `6:` JES ..HERS VE,RIF:ICATION REQUIRED
.: _. _
Fenestration"
Building Front Orientation: All Four onentations Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (N) 1,370 247
Fuel Available at Site: Natural Gas (E) 586 235
Raised Floor Area: 0 (S) 1,295 126
Slab on Grade Area: 3,612 AM 730 384
Average Ceiling Height: 11.1 Roof 4,619 0
Fenestration Average U-Factor: 0.31 TOTAL: 991
Avera e SHGC: 0.24.... Fenestration/CFA, Ratio: .... - _..:; 27.4
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and.specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company GMEP Engineers
1/21/2015
Address 4400 Campus Drive Name Gangyi Zhou 0/
City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone 9497521612 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Pekarek-Crandell,Inc
Address 31411 Camino Capistrano Name
City/State/Zip San Juan Capistrano, CA 92675 Phone 949.487.2320 Signed License # Date
Ene Pro 5.1 b Ene Soft ' UserNumbertl6$ `:',:.:RunCoder 2015.01-21T17 16:03 `.: :16: 63276 Page 8 of 15
CERTIFICATE OF COMPLIANCE, Residential ; :.:`...:. .(Part,4 of.5) ,, ..•... CF-1 R
Project Name
Andalusia Plan 23A
Building Type m Single Family :O Addition Alone'", .,';:.`
❑ Multi Family 10 Existing+ Add ition/Alteration '
Date
1/21/2015.
OPAQUE SURFACE
DETAILS. "- r
Surface
Type
Area
U-
Factor
insulation
Am.
Tilt
Status
" 'Joint A'ppendiz`
4
Location/Comments .
Cavity
Exterior
. Frame
Interior,
.Frame
Wall
347
0.057
R-19
4.0-..
None
0
90
New
4.3.1-A5
Great Room/EntryMlet BE
Wall
92
0.057
R-19
4.0 '
None
90
90
New
4.3..1-A5
Great Room/Entry/Wet Ba
Wall
60
0.057
R-19
4.0
None
270
90
New ;
4.3.1-A5
Great Room/Entry/Wet Ba
Slab
926
0.730
None +
0
180
1 New
4.4. 7-A 1
Great Room/EntrylWet Bi
Roof
926
0.031
R-30
0
0 New
4.2.1-A20
Great Room/Entry/Wet Ba
Wall
120
0.057
R49
4.0
None
0
90
New
4.3.1-A5
Master Suite
Wall
310
0.057
R-19
4.0.
None
. :
180
90
New
4.3.1-A5 ` ..
Master Suite
Wall
199
0.057
R-19 ;..
4.0
„•None
270
90
New'. _!..
4-3. I-A,57
Master Suite "
Slab
608
_0. 730
None
0
180
New
4.4.7 A 1:
Master Suite
Roof
608
0.031
R-30
0
0 New
4.2.1-A20
Master Suite
Wall
87
0.057
R-19
4.6
None
0
90
New
4.3.1-A5
Morning Room/Kitchen
Wall.
135
0.057
R-19
14.0
None
.180
90
New
4.3.1-A5
Morning Room/Kitchen
Wall
67
0.057
R-19
4.0
None
90
90
New
4.3.1-A5
Morning Room/Kitchen'
Slab
609
0.730
None
0
'' 180
New.
4.4.7-A1
MorningRoom/Kitchen
Roof
609
0.031
R-30
0
0 New
4.2.1-A20
Morning Room/Kitchen
Wall _.
261
0.057
R-1:9 :.
4.0.-._.......
None
...
01.
FENESTRATION,SURFACE.DETAIL$.
:
ID
Type
Area
U-Factor
" 'SHGC
Azm:.'
Status
Giazin .� e
Location/Comments
1
Window
4.0
0.300
NFRC
0.17
NFRC
.0
New Fixed
Glass
Great Room/Entry/Wet Bar,. ;
2
Window.
4.0
0.300
NFRC
0.171
NFRC `
0
New Fixed
Glass.,
Great Room/Entt /lWet
3 .
Window
27.5
0.300
IVFRC •
0.1.7
NFRC
0
New Casement.'
-. ? °
Great Room/Entry t Bar.
4
Window.
17.5
0.300
NFRC
'017
NFRC _.
-.0
New Single
Hung ::'
GieafRoom/Entry/INefBar
5
Window
144.0
0.320
NFRC
.0.30
NFRC
`90
New,.'.. SlidingGlass,Door
"
Great Room/Entry/1Net.Bar.
6
Window
30.3
0.320
NFRC
0.36
NFRC.,.."
90
New French
Glass:Door', _. '• :_
Great Room/Entry/lNet Bar
7
Window
192.0
0.320.
NFRC
6.30
NFRC . `
--,270,
New. " ': Sliding
Glass Dpor, ..
Great RoorNEntryllNet'Bar `•
8
Window
38.5
0.300
NFRC-,'0't
7;
NFRC . "' .
, . _: 270
New ,.. ,, ; Casement
-, :;
Great RoOm/EnfrylWet,
9
Window
16.5
0.300
NFRC
.0.17
NFRC ....
J..80
New Fixed
Glass
Master'Suite
10
Window
16.5
0.300
NFRC
6.17
NFRC... '
` ,;180
New f Casement
Master'Suite"
11
Window
16.5
0.300
NFRC
0'17
NFRC,'_'
. 180
.New ' "Casement,..,
` `
Master Suit .
- 12
Window
4.5
0.300
NFRC ."
"• 0 17
1VFRC.. ,
.:180
New. Casement.
Master Suite
13
Window
16.5
0.300
NFRC -
.0.11
NFRC
180
New Casement'
Master Suite.. ,. • , . '
14
Window
24.0
.0.320
NFRC
0.30
NFRC
270
New French
Glass Door'
Master Suite •
15
Window"
57.0
0.300
NFRC
0.17
I.NFRC ..
270
New Fixed
Glass.
Master Suite
16
Window
33.01
0.300 1
NFRC
047
1 NFRC
01
New _ Fixed
Glass
Morning Room/Kitchen .
(1) 1-1-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC.T e:. ,1,16-8 =.Default Table from Standards„ NFRC ,. Labeled Value
EXTERIOR
SHADING.,DETAILS
ID
Exterior Shade Tyl5e
SHGC
Window
Oveehan'
Left Fin
"'sRi ht:Fin
H t
Wd
Len
' H t.
LExt
. RExt
Dist
Len
H t
Dist
I Len `
H t
1 .
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
.5.5
5.0
12.0
0.1
20
2.0
`
-4
Bug Screen
0.76
5
Bug Screen
0.76
12.0
12.0
12.0
0.1
2.0
2.0
6
Bug Screen
0.76
8.0
4.0
2.6
0.1
2.0
2.0
7 '
Bug Screen
0.76
12.0
16.0
15.0
0.1.
2.0
2.0
8
Bug Screen
0.76
TO
5.5
9.0
0.1
2.0
2.0
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0:76
13
Bug Screen
0.76
14
Bug Screen
0.76
8.0
3.0
9.0
0.1
2.0
2.0
r
15 IBug
Screen .
0.76
8:0 1
7.1
1.0
0.1
2.0
2.0
16 IBug
Screen • 1
0.76
EnergyPro5.lbyEne 'Soft ' `.' use? Number.: 8165' ' RtunCode: 20:15-01=21 T,1716:b3 fi7: ;63276 Pa e 9 of a5.
CERTIFICATE OF `COMPLIANCE , .R sidential .�Parf 4 6 .5) CF-1 R
Project Name
Andalusia Plan 23A
Building Type m Single Family ❑ Addition Alone '
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1112112015
OPAQUE SURFACE
DETAILS
Surface
Type
Area
U-
Factor
Insulation
Azm
Tilt
Status
Joint Appendix
4
Location/Comments
Cavity
Exterior
Frame
Interior
Frame
Wall
413
0.057
R-19
4.0
None
180
90
New
4.3.1-A5
Bedrm20edrm 3/Powder/
Wall
60
0.057
R-19
4.0
None
90
90
New
4.3.1-A5
Bedrrn2/Bedrrn 3/Powder/
Slab
934
0. 730
None
0
180
New
4.4. 7-A 1
Bedrm2Bedrm 3/Powder/
Roof
9341
0.031
R-30
0
0 New
4.2.1-A20
Bedrm2Bedmr 3/Powder/
Wall
309
0.057
R-19
14.0
None
1
0
90
New.
4.3.1-A5
Casita/Bath4/Bedrm4
Wall
133
0.057
R-19
4.0
None
90
90
New
4.3.1-A5
Casita/Bath4/Bedrm4'
Wall
312
0.057
R-19
4.0
None
180
90
New
4.3.1-A5
Casita/Bath4/Bedrm4
Wall
88
0.057
R-19
4.0
None
1 270
90
1 New
4.3.1-A5
CasitaBath4/Bedrm4.
Slab
536
0.730
None
0
180
New
4.4.7-A 1
Casita/Bath4/Bedrm4
Roof
1,543
0.031
R-30
0
0 New
4.2.1-A20
Casita/Bath4/Bedrrr4
FENESTRATION.S.URFACE
DETAILS.''
ID
Type
Area
"Ll-Factor ., '
` SHGC
Azm-'I
'Status
Glazin `T e_
Location/Comments
17
Window
33.0
0.300
NFRC
0.17
NFRC
90
New Fixed
Glass
Morning Room/Kitchen
18
Window
4.5
0.300
NFRC.
0.17
NFRC
0
New Casement
Bedrrri2/Bedrm 3/Ppwder/Laun
19
Window
48.0
0.320
NFRC
0.30
NFRC
.0
New Sliding
Glass Door.
Bedrm2/Bedrm 3/Powder/Lauh
20
Window
72.0
0.320
NFRC
0.36
NFRC
0
New Sliding.Glass
Door
Bedrm2/Bednn: 37Powder/Leu
21
Window
4.5
0.300
NFRC
0.17
NFRC
0
New Casement
Bedrm21Bedm► 3/powder/Lau
22
Window
4.5
0.300
NFRC.
0.17
NFRC
180
New Casement
Bedrrn2/Bedmi 3/Powder/Lauh
23
Window
4.5
0.300
NFRC
0.17
NFRC
180
New' Casement
Bedrrn2/BedrM'3/PowdeNLaun
24
Window
4.5
0.300
NFRC
0.17
NFRC
180
New Casement
Bedrrj72Bpdrm 37PowdeNL6un
25
Window
4.5
0.300 .NFRC
0.17
NFRC
180
New Casement
Bedrm2/Bedrm 3/Powder/La07
26
Wndow
9.0
0.300
NFRC
'0.17
NFRC
'18.0
New Casement
Bedrm2/Bedrm 31PowdeiYLaun
27
Window
9.0
0.300.
NFRC
0.17
NFRC
0
New Casement
Casita/Balh4/B.edrm4. .
28
Window
9.0
0.300
NFRC
0.17
NFRC
0
New Casement
Casita/Bath4Bedriri4
29
Window
4.5
0.300
NFRC
0.17
NFRC
0
New Casement
Casga/8ath4Bedrm4
30
Window
4.5
0.300
NFRC
0.17
NFRC
0
New Casement
_ .
Casita/Ba'th4/Beo :4 `
31
Window
4.5
0.300
NFRC
0.17
NFRC
0
New Casement
Casfta/Bath4Bedrrn4..
32
Window
27.5
0.300 1
NFRC
0.17
NFRC
90
New Sliding
Glass
CasitaBath4Bedrm4
(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 11.6,-B =_Default Table -from Standards, NFRC = Labelad Value ,-
EXTERIOR
SHADING DETAILS. F
ID
Exterior Shade Type
SHGC
Window
Overhang'
'Left Fin
Right Fin
H t
Wd
Len
H t
I LExt
RExt
Dist
Len
H t
Dist
Len
H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20 JBug
Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
31
Bug Screen
0.76
32 JBug
Screen
0.76
EnergyPro, 5.1 by EnergySdft ' 0ser.Numbeit,8165 :_: ;RunCode 2015.01-21T17:16:03 40: 63276
CERTIFICATE OF COMPLIANCE `Residential (Part 4 of ,5 CF-1.R
.m
Project Name
Andalusia Plan 23A
Building Type Single Family O_ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
112112015
OPAQUE SURFACE.
DETAILS
Surface
Type
Area
U-
Factor
Insulation
Azm
Tilt
Status
Joint Appendix
4
Location/Comments
Cavity
Exterior
Frame
Interior
Frame
FENESTRATION
SURFAC.E.DETAILS
, .:...
ID
Type
Area
U-Factor
- SHGC
Aim
Status
Glazing T e
Location/Comments!
33
Window
4.5
0.300
NFRC
0.17
NFRC
180
New Casement
Casfta1Bath41Bedrm4
34
Window
24.0
0.320
NFRC
0.30
NFRC
180
New French
Glass Door
Casfta1Bath41Bedrm4
35
Window
72.0
0.320
NFRC
0.30
NFRC
270
New Sliding
Glass Door
Casita/Bath4Bedrm4 `
(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: _ _116-5 = Default Table from Standards,. NFRC = Labeled. Value
EXTERIOR.
SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
Ove hang
Left Fin
Right Fin
H t
Wd
Len
H t
LExt
RExt
Dist
Len
H t
Dist
Len
H t
33
Bug Screen
0.76
34
Bug Screen
0.76
8.0
3.0
4.0
0.1
4.0
4.0
35
Bug Screen
0.76
EnergyPro 5.1 by Ene Soft, . ;User'Number;8M5 , -RunCode: 2015-0141T1,1.16 03 , ,='';1D:,:63216 :_,.>.. , : . ' ;Pa 11 of 15
CERTIFICATE OF COMPL.IANCE:. Residen_ tal '. Part 5 of 5) CF-1 R
Project Name
Andalusia Plan 23A
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
112112015
BUILDING ZONE INFORMATION:.....:;
System Name
Zone Name
Floor Area ft
Volume
Year Built
New
Existing
Altered
Removed
3 T
Great Room/Entry/Wet Bar
926
13,057
2.5 T
Master Suite
608
6,136
2 T
Moming Room/Kitchen
609
6,151
3 T
Bedr7n243edrm 3/Powder1Laund
934
9,428
2 T
Casita/Bath4Bedrm4
536
5,355
Totals
3,6121
0
0.
0
HVAC SYSTEMS
System Name
at .
Heating Type e
Min. Eff.
Cooling Type "
Min. Eff.
Thermostat 7 e ;"
Status .
3 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER Setback
New
2.5 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER Setback
New .
2 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
17.0 SEER Setback,
New
3 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER Setback..
New.
2 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
17.0 SEER Setback
`
New
HVAC DISTRIBUTION,
System Name
Heating
Coolin
Duct Location
Duct
R-Value
Ducts
Tested?
Status
3 T
Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
m
New
2.5 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
m
New
2 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
E)
New
3 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.01
m 1
New
2 T Ducted
Ducted
. Attic, Ceiling Ins, vented
8:0
m
New
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
2
Small Gas
Kitchen Pipe Ins
40,000
50
0.58
n/a
n/a
New
MULTI -FAMILY WATER,
HEATING.
DETAILS
:' '' :." ..:
1 YPI30NIC.
HEATING
SYSTEM
PIPING .. , ..
Control
Hot Water Piping Length
ft
0
ro
Q —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty.
HP
Plenum
Outside
Buried
13
11
Energ yPro 5.1 by Energ SoR User Number. 61,65 RunCode..2015-01-21T17:16:03.- `� )D:.63276 Page 12 of 15
MANDATORY..MEA$URES`SUMMARY Res�dent�al .. Page 1 ofi:3. ` MF-1 R
Project Name * Date
Andalusia Plan 23A 1/211'2015
NOTE: Low-rise residential `buildings subject to`the'Sfandards must comply with' ail applicable mandatory measures I ted,'regardless of"
the compliance approach used. More stringent energy -measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF-
1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R
Form with plans.
Building Envelo 'e 1Vleasbres '
116 a 1: Doors and windows between conditioned and unconditioned s aces.are. manufactured to•limit.air leakage..
§116(a)4: Fenestration products (except field -fabricated windows)'have'a'iabe'liisting t 'certified U-Factor,'certified Solar Heat -Gain
Coefficient SHGC , and infiltration that meets the requirements 10-1.11 a .
117: Exterior doors and windows are weather-stripped; all joints and penetrations.are caulked and,sealed: ' '
118 a : Insulationspecified or installed meets. Standards. forJnsulatin Material. Indicafe t e and include on CF-6R.Form.
118 i : The thermal emittance and solar reflectance values of the`cool roofing material meets the' re uirements of 118 i when the
§ (7 g q § (7 -
installation of a Cool Roof is s ecified on the CF-1 R Form..•
* 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor:
150 b : Loose fill insulation shall conform with manufacturer's instal led.desi n labeled R-Value. '
* 150 c Minimum R-13 insulation in wood -frame wall orequivalent U-factor. .
* 150 d : Minimum R-13 insulation in raised.wood-frame floor ore uivalent.U-factor..-
150 f : Air retarding wrap is tested, labeled,.and installed according. to ASTM E1677-95 2000 .when specified. on the CF-1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 1.4 or 16.
§150(I): Water absorption rate for slab edge insulation material alone without facings is_no'greater than 0.3%: water vapor permeance ,
rate is n2..0ected hsdms a and UIiht detm.ifrom.erioration
'Fire laces, Decorative.-ti 'A ' liances and.Gas Lo Measures
150 e 1 A: Masonry or factory -built fireplaces have a closable metal, or qlass door coverin 'the entire o e' of the firebox
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside airinfake', which is at"least six square inches'in area and is'
equipped with a with a readily accessible, operable,, and.ti ht-fittin damper and..or;a combustion -air. control device.
§150(e)2: Continuous burning pilot lights and the us'e'of indoor air for cooling a firebox jack6f,"Ohen That indoor air is vented to'fhe
outside of the building, are rohibited,,.. ,..:,.;,
Space Conditionin ;Water Heatin aniiPlumbing S stem'Measures
§110-§113: HVAC equipment, water'heaters, showerheads, faucets'and all other'regulated appliance's are certified'.6y the Energy"
Commission.- ,
,§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release"
valve, backflow prevention, pump isolation,valve, and, recirculation. loo. :connection re. ui.rements of, 113 c 5.
§115: Continuously burning pilot lights are prohibited for natural gasp fan -type central furnaces,'househo1d cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters. '
1 50h : Heating.and/or cooling loads are calculated in accordance_ with:ASHRAE, SMACNA or ACCA.
150 i : Heating systems are equipped with thermostats that meet the setback.re uirements.of Section+1.112(c).
§1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-.1.2_or, reater.. .
§1500)1 B: Unfired storage tanks, such.as storage tanks or backup tanks for'solar water=heating system, or other indirect hot water ,
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the,
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculatinci sections of hot water i es are•insulated per Standards_ Table 150.13
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping h§ulated between heating source and indirect hot
water tank shall be insulated to Table 1.50-13 and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150 ' 3A: Insulation is prote7cted from damage, including that due to sunli ht,:moisture, a ui ment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines indudesavaporretardant or is enclosed entirely in
,conditioned space. '
150 ' 4: Solar water -heating systems and/or collectors are certified by the SoW'Ratind and Certification Cor oration.
EnergyPro 5.1 by EnergySoft User Number. 81.o.. RunCode., 2015-01.21T17 l6:63 !p 63276, Page 13.of 15
MANDATORY MEASURts'sUMMARY Residential :." Pa e 2 of 3 MF-1 R
Project Name
Date
Andalusia Plan 23A
112112015
150 m 1: All air -distributions stem ducts and leriums installed, are' insulated to meet t' § ( ) '�' y � p he requirerrtenfs of CIVIC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4.inch, the combination of mastic and either,mesh or to e.shall be.used . .
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support_platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the'cross-sectional area
of the ducts.
§150(m)2D: Joints and seamsof duct systems and their components shall not be sealed with clothback* rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150 m 7: Exhaust fans stems have back draft or automatic dampers. ,
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible; nianually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porousinner cores.
§150(o): All dwelling units shall meet the requirern6hts of ANSI/ASHRAE Standard 62.2-20.07 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that.Standard.
Pool and Spa.fleating Systems an, d.E ui ment:Nleasures:
§114(a): Any pool or spa heating system shall be"ceifified to have: a thermal efficiency that co"niplies with the Appliance
Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions;' and
shall not use electric resistance heating, or,a pilot. light.
§114(b)1: Any pool or spa heating equipment shall be installed.with at least 36" of pipe between filter and heater,'or dedicated suction
and return lines, or built-up connections for.future solar heating.
114 b 2: Outdoor pools ors as that have a heat pump or, as heater shall have a cover.
§114(b)3: Pools shall have directional'iril'ets that adequate'lyrriiii fhe pool water', and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods,
150 : Residential ool.:s stems or,e ui me.nt meet the• um .,sizin , flow rate, piping, filte.rs,_and:valve requirements of §15.0
Residential Lighting Measures: "
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacythat`is no lower'than the efficacies
contained in Table 150-C and is not a low efficac . luminaire asspecified by § 1 50.k 2.
150 k 3: The wattage of permanently installed luminaires shall be determined.as specified by §i30(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire'o*r exhaust -fan shall contain .
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 150 k .
150 k 7: All switching devices and contmis.shall meet the requirements of. 150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 2b wafts of power per linear foot of
illuminated cabinet.
Ene►yyPro 5.1 by EnergySoft . User Number 8165 , j2unCode: 2015 01 2.1T17;16:03 , Ip: 6327fi ._' ,Page 14 of 15
MANDATORY MEASURES SUMMARY 'Residen#ial (Page3. of 3 MF-1 R:..
Project Name
Date
Andalusia Plan 23A
112112015
150 10: Permanently installed luminairesin bathrooms,'attaclied and'detached ara eS, laund''rooms; closets and utilif rooms "
§ k () Y i9 9 rY Y
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (FMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to 130 d .
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with'the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146. 0
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable re uirements of 119.
EnergyPro 5.1 by EnergySoft User Number. 8165 RunCode: 2015-0141 r ..l :6.3 ;: ID: 03276. „ ';,•:. Page 15 of 15 . .
BUILDING ENERGY ANALYSIS::REPORT
PROJECT:
Andalusia Plan 23-B ,
f Coral Mountains; 75' Lots
.La Quinta, CA
i Project _Designer:
Pekarek-Crandell, lnc
31411 Camino Capistrano ,
San. Juan Capistrano, CA 92675
949.487.2320
i
Report Prepared by:
Gangyi Zhou
GMEP.Engineers
4400 Campus Drive
Newport Beach, CA 92660 .
,Job Number:
63276 '
Date: _ 4,
1 / 13/2015' `
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.'
This program developed by EnergySoft, LLC — www.ener§ysoft.com.
Ene Pro 5.1 by Ene Soft User Numbee 8965. `. RunCode:3015-01-33T12:05.32 ID: 63276
IL
t
PERFORMANCE 'CERTIFICATE.. Residential .:...,.,. ,.Part.1 of'5)
CF-1 R
Project Name
Andalusia Plan 23-B
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111312015
Project Address
Coral Mountains 75' Lots La, Quinta _,,.
California Energy Climate Zone
CA Climate Zone.15 ,.
Total Cond. Floor Area
31612
Addition
n/a
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
El Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. ,
INSULATION
Construction, Type e ; .
Area Special
Cavity (ft) Features.(see.Part, 2,of,5) . ..._Status....
Wall Wood Framed R-19 3,936 Ext=R-4.0
New
Slab Unheated Slab -on -Grade None 3,369 Perim = 408'
New
Roof Wood Framed Attic R-30 4,219 Radiant Barrier
New
FENESTRATION U- Exterior
Orientation Area fi)...Factor_.; SHGC_. Overhang Sidefi . s ,._ Shades . Status .. ,..
Front (N) 41.0 0.300 0.17 none none Bug Screen
New
Front (N) 68.0 0.300 0.17 none none Bug Screen
New
Front (N) 17.5 0.300 0.17 none none Bug Screen
New
Left (E) 144.0 0.320 0.30 10.0 none Bug Screen
New
Left (E) 30.3 0.320 0.30 none none Bug Screen
New
Right (W) 192.0 0.320 0.30 10.0 none Bug Screen
New
Right (M 38.5 0.300 0.17 none none Bug Screen
New
Rear (S) 16.5 0.300 0.17 none none Bug Screen
New
Rear (S) 103.0 0.300 0.17 none none Bug Screen
New
Right (Vt) 24.0 0.320 0.30 none none Bug Screen
New
Right (K9 64.0 0.300 0.17 none none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff
Cooling Min. Eff Thermostat,_ .Status
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback
New
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback
New
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 17.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct. Location . _ . R-Value,
3 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
2.5 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
2 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
WATER HEATING
Ot . Type Gallons. :Min. Eff. „ .,:,Distribution Status. ...
2 Small Gas 50
0.59 Kitchen Pipe Ins
New
EnergyPro 5.1 by EnergySoft User N4m0di. 8165, . .,_
'RunCode:2 15-0141T12 05:32 , fD:.6327.6 : • :. ' '
:Page 3-of 15...
PERFORMANCE, :Residential..... Part 1' of 5 *,.
CF-.1 R ..
Project Name
Andalusia Plan 23-B
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111312015
Project Address
Coral Mountains 75' Lots La Quinta ..::
California Energy Climate.Zone
CA Climate Zone ,15. ,.
Total Cond. Floor Area
„ .. 3,612
Addition
n/a .
# of Stories
2 .
FIELD INSPECTION ENERGV CHECKLIST
El Yes ❑ No HERS Measures -- If Yes, A CF-413 must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features. --.If Yes, see Part,2 of,5 of this form for,details.- .
INSULATION ' ` Area Special
Construction ..Type Cavity (ft) . Features, seq,PArt 2.of.5 . ,Status.
FENESTRATION U- Exterior
Orientation . Area(ft) Factor, .,:SHGC. _Overhang SidefinsShades _ ,... , .,:.:. Status ..::..:,
Left (E) 33.0 0.300 0.17 none none Bug Screen New
Front (N) 120.0 0.320 0.30 none none Bug Screen New
Left (E) 27.5 0.300 0.17 none none Bug Screen New
Rear (S) 24.0 0.320 0.30 none none Bug Screen New
Right (Kq 72.0 0.320 0.30 none none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff .., Cooling. Min. Eff Thermostat Status.. ;..
1 Split Heat Pump 8.50 HSPF Split Heat Pump 15.0 SEER Setback New
1 Split Heat Pump 8.50 HSPF Split Heat Pump 17.0 SEER Setback New
HVAC DISTRIBUTION Duct
Location . Heating. Cooling Duct Location A...:.. ; , . R-Val.ue..,..._::Status
3 T Ducted Ducted Attic, Ceiling Ins, vented 8.0 New
2 T Ducted Ducted Attic, Ceiling Ins, vented 8.0 New
WATER HEATING
Qty. Type Gallons _ . Min.. Eff ,,.:Distribution .:_ ;, ; .Status
EnergyPro 5.1 by EnergySoft Wer lVumber.`8165 : , RunCode:,2015-1=1.3TO.65M ID; 63276.
Page 4 of 15 .
PERFORMANCE CERTIFICATE -;Residential '; Part of .5)
Project Name
Andalusia Plan 23-B
Building Type ® Single Family 0 Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1/13/2015
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The. enforcement agency .
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on'the adequacy of
the special justification and..documentation submitted.. ,
Compliance for all orientations is specified, see ;section 151 (c} 2 of the Standaids and section 7.6.2 of the esidential Compliance Manual.
The Roof R-30 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility arid'installation criteria as specified in Residential
Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
.Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form fQr each_ of.the measures,listed below for,final to be, iven.. _ k:..., ..;
The Cooling System 3 T includes credif for a f2.5 EER Condenser: 'A certified HERS rater must`field verify the installation of the correct Conderiseh"
The HVAC System 3 T includes'credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cf n.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 3 T includes credit for verified adequate airflow. 'A certified HERS iater must diagnostically measure airflow of the HVAC System.
The HVAC System 3 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to 'verify that duct leakage
meets the specified criteria.
The Cooling. System 2.5 T includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 2.5 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfrn.
Compliance credit for quality installation of insulation has been used. HERS field verification Is required.
The HVAC System 2.5 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 2.5 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System 2 T includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 2 T includes credit for Veered Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Ene Pro 5.1 b ,Ene Soft ' 'Lls&) Number^8165 -'
PERFORMANCE 'CERIFICATE Residential ; _ .... (Part 2 of 5) C.F-1 R .
Project Name
Andalusia Plan 23-8
Building Type ® Single Family" 0 Addition Alone `
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111312015.
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject.a. building or design that otherwise complies based on the adequacy of
the special 'ustification.and documentation.submitted...:....
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS. Rater.. The inspector, must receive a
completed CF-411.form for each.of,the. measures listed below for final to be fiver :
Compliance credit for quality installation of Insulation has'3e9n'itsed. HERS field ve"rirication is ►equireii
The HVAC System 2 T includes credit for verified adequate ain9ow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 2 T incorporates HERS verged Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
The Cooling System 3 T includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 3 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 3 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 3 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
The Cooling System 2 T includes credit fora 13.0 EER Condenser. A certified HERS rater must field'verify the installation of the correct Condenser.
The HVAC System 2 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 2 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
EnergyPro 5.1 by Ene Sofl User Number• "8165 .. ,, . •.ltunCode:� 2015c01-13.T12:05:32 � ' '- ID: 63276 � ' . � PTge 6 of 15
PERFORMANCE CtATWICA!-�,','.-'R-q§1de' lig.1 CF-1 R
(Part 2 of 5) . .
Project Name
Andalusia Plan 23-B
Building Type 0 Single Family 0 Addlition-Alone " ' t' - � " - '
0 Multi Family 0 Existing+ Addition/Alteration
Daile - -
1 111312015
SPECIAL FEATURES INSPECTI bN - CH , Eld, K . LI - S I T
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, an ' d special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFIcAt`�-``
ION.
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R, form for.,e;ach..Qf.the.measures Ii%qd..OeIQwfo e gi
r.fipal. to b
The HVAC System 2 T incorporates RERS VerifleMica,6555e. HERS rteid Zification ind diagii6stie-testwo is required to vefify that dudt leakage
meets the specified criteria.
EnergyPro 5.1 by Ener-qySoft User ivurh�be?,.',8f65 �-':-'.--'-`AunCode: - 161 . 5-0 .1-1JY11.65.4� ID: 6J276 Pa_qe 7 of 15
PERFORMANCE CE.RTIFLCATE Residential:. (Part 3 of 5) CF-1 R.,
Project Name
Building Type .0 Single Family 121 Addition Alone `"`
Date
Andalusia Plan 23-B
❑ Multi Family ❑ Existing+ Addition/Alteration
1111312015
ANNUAL ENERGY USE 'SUMMARY ..
Standard Facing Margin Facing Margin Facing Margin " � 'Facing Margin
TDV kBtu/ft2- r North East South West
Space Heating 5.49 4.87 0.62 4.83 0.66 4.08 1.41 4.45 1.04
Space Cooling 59.30 43.61 15.68 43.46 15.84 44.06 15.24 44.43 14.87
Fans 11.80 11.50 0.30 11.47 0.33 11.63 0.18 11.69 0.11
Domestic Hot Water .9.51 12.25 -2.74 12.25 -2.74 12.25--274' 12.25- -2.74
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
. Totals 86.10 72.23 13.86 72.01 14.09 72.02 14.08 72.83 13.27
Percent Better, an Standard: 1§..1% - : 16.4 %, 16.4 % . 45,4
BUILDING .COMPLIES -HERS .VERIFICATION REQUIRED
Fenestration'"''
Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall Area Area
,Number of Dwelling Units: 1.00 (N) 1,615 247
Fuel Available at Site: Natural Gas (E) 816 235
Raised Floor Area: 0 (S) 1,630 144
Slab on Grade Area: 3,369 (169 890 391
Average Ceiling Height: 11.1 Roof 4,219 0
Fenestration Average U-Factor: 0.31 TOTAL: 1,015
Average SHGC:. _ :.,:_ ,_ ., .0.25 .. Fenestration/CFA Ratio: .28.1 i
REMARKS.
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company GMEP Engineers
1/13/2015
Address 4400 Campus Drive Name Gangyi Zhou
City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction -documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Pekarek-Crandell,lnc
Address 31411 Camino Capistrano Name
City/State/Zip San Juan Capistrano, CA 92675 Phone 949.487.2320 Signed License # Date
EnemyPro 5.1 by Enem YSoft UserNurriber.• 8165 . . ' RunCode: 2015-01=13 12:05 32 ID: 63276 Page 8 of 15
CERTIFICATE OF COMPLIANCE :Residential ; ;; `. ::.::(Part,4. Hof 5) ..•.:>.: CF=1 R.:
Project Name
Andalusia Plan 23-8,::., _.:- . ,
Building Type ® Single Mily" Cl Addition Alone`
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111312015
OPAQUE SURFACE
DETAILS
Surface
.Type
Area
U-
Factor
Insulation'
Azm.
Tilt
Status
`Joint Appendix
4
Location/Comments .
Cavity
Exterior
Frame
Int.eriorl
Frame
Wall
347
0.057
R-19
4.0
None
0
90
New
4.3.1-A5
Great Room/Entry/Wet Be
Wall
.92
0.057
R-19_-
4.0
None
90
90
New
4.3.1-A5
Great Room/Ent 7WetBa
Wall
70
0.057
R-19
4.0
None
270
90
New
4.3.1-A5
Great Room/Entry/Wet Ba
Slab
926
0.730
None
0
180
New,
4.4.7-A 1
Great Room/Entry/Wet Ba
Roof
926
0.031
R-30
0
1
0 New.
4.2.1-A20
Great RoornlEntrylWet Ba
Wall
135
0.057
R-19 .
14.0
None
0
•90
New
4.3.1-A5
Master Suite
Wall
293
0.057
R-19
. 4:0
None
180
90
New......4,3.1-A5.,.
Master Suite _,.:..:
Wall
132
-0.057
R-19
4.0
None '
. . `"
�
�� 270
-
� 90
New",' •
..
�{ 3.1=A5 : "� `. ' .- .'
.. Master Suite
Slab
608
0.730
None
0
180
New
4.4.7-A 1.
Master Suite
Roof
608
0.031
R-30
0
0 New' : ,
4.2.1 A20
_.
Master Suite
Wall
87
0.057
R-19
4.0 .
None.
0
90
New :..4:3.1'A5
MorningRm/Kitchen'
Wall
160
0.057
R-19
14.0
None
180
90
New - '
4.3.1-A5
Momin `Rm%Kitchen'.: `
Wall
27
0.057
R-19
4.0
None
90
90
New
4.3.1-A5
Morning Rm/Kitchen` '
Slab
6091
0.730
None
0
180
New'
4.4. Z-A9
Morning Rm/Kitchan
Roof
6091
0.031
R-30
01
0 New
4.2.1-A20
Moming Rm/Kitchen ,-•
Wall _
3381
0.057
R-19
> 4.0 ., - ..,.1
None .:.
0
90.
,New :
4.3:1-A5 , ,. : •:.
Bedm 2/Pwdi1L "' %Bal
FENESTRATION.
SURFACE
DETAILS 1 1'r
ID
Type
Area"
U-Facioe ;'
`SHGC
Aim"''Status
GlazinT a
Location/Comments
1
Window.
4.0
0.300
NFRC
0.17
NFRC
0
New Fixed
Glass..
Great Roorri/EntrylWeii'Bar....
2
Window
4.0
0.300
NFRC
0.17
NFRC
' 0
New Fixed
Glass : "
Great.Room/Entry/WetBar,." .
3
Window
27.5
0.300
NFRC
0.17:
NFRC: .
;0
New . Casement
:: < ' :
GreatRoorri/En . M/efBar'
4
Window
17.5
0.300
NFRC .
0.17
NFRC
; 0
New -Single
Hung
Great Room/EntryANef Bar ; '
5
Window
144.0
0.320
NFRC
0.30
NFRC
90
New Sliding
Glass Door
Great Room//Entry/Wet:Baf
6
Window
30.3
0.320
NFRC
0.30
NFRC... ,
';;90.
New .. " ` French
Glass, Door'.'" ' ' = -
,Great Room/EntryM!gt Bar
7
Window
192.0
0.320
NFRC.
0.30
NFRC
270:
New ' ` :` Sliding
Glass'Door ; : ?,' %=
"Great•Roorri/EntryM!et.Bw.',;'
8
Window
38.5
0.300
NFRC"- -
.. 0.17
NFRC
'270
New' = Casement.-,
Great:Room1Entry/Wet•Bar,
9
Window •
16.5
0.300
NFRC
0.17
NFRC
.180
New. ' . Fixed
Glass
Master Suite:
10
Window
16.5
0.300
NFRC
0.17
NFRC
180
New Casement
Master Suite .
11
Window
16.5
0.300
NFRC ..'
0.17
NFRC...,,
fi80
New , ',: , : Casement
Master, Suite
12
Window
4.5
0.300
NFRC
0.17
NFRC
180
New Casement:
`..,
Master Suite
.13
Window
16.5
0.300
NFRC
0.17
NFRC
'180
New Casement
Master Suite
14
Window
16.5
0.300
NFRC
0.11
NFRC,
180
New. Casement
.
Master Suite
15
Window
24.0
0.320
NFRC
0.30
NFRC
270
New French
Glass Door
Master Smie
16
Window
64.0
0.300
NFRC
0.17
i NFRC
_ -270
New Fixed
Glass
Master Suite
'(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC T e.: . 116-B. = Default. Table from Standards, NFRC .= Labeled Value..
EXTERIOR
SHADING.pETAILS
IDJ
Exterior Shade Type
SHGC
Window
Overhang
Left Fin
Right Fin
H t
Wd
Len .
H t
LExt
RExt
Dist
Len
H t
Dist
Len
H t
1 -
Bug Screen
0.76
2 _
Bug Screen
0.76
3
Bug Screen
0.76
4 -
Bug Screen
0.76
5
Bug Screen
0.76
10.0
12.0
10.0
0.1
2.0
2.0
6
Bug Screen
0.76
t _
7
Bug Screen
0.76
10.0
16.0
10.0
0.1
2.0
-2.0
8
Bug Screen
0.76
9
Bug Screen
0.76
'
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
-16
Bug Screen
0.76
EnergyPro,5.1 by EnergySoft User Nurnb6r. 8166. ' `, >.`RunCode: 2015-01-13T12:05:32 -.ID: $3276 ; ^ :: •: {'a e 9 of 15
CERTIFICATE OF COMPLIANCE:' :Residential-(Part`:4 of 5) .-• CF-1 R.
Project Name
Andalusia Plan 23-8 .
Building Type m Single Family "❑'Addition'Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date `
1/13/2015
OPAQUE SURFACE
DETAILS
Surface
Type
Area
U-
Factor
Insulation
Azm,
.Tilt
{
Status
Joint Appendix
4
Location/Comments
Cavity
Exterior
Frame
Interior.
Frame
Wall
492
0.057
R-19
4.0
None
180
90
New
4.3.1-A5
Bedrm2/Pwdr/Laund /Bat
Wall
.120
0.057
R-19
4.6
None'
90
90
New,
4.3.1-A5
Bedrm21Pwdr1LaundryvBa1
Slab
691
0.730
None
0
180
New i
4.4.7-A1
Be drm 2(PwdrIL a un drylBa
Roof
291
0.031
R-30
0
'0
New.
4.2.1-A20
Bedrm21Pwdr1LaundryvBa1
Wall
154
0.057
R-19
4.0
None
0
90
New;
4.3.1-A5
Bedroom 31Bath 3
Wall
230
0.057
R-19
4.0
None
180
90
New
4.3.1-A5
Bedroom 3/Bath 3
Wall
210
0.057
R-19
4.0
None
90
90
New
4.3.1-A5
Bedroom 3/Bath 3
Wall
.210
0.057
R-19
4.0
None
270
90
New
4.3.1-A5
Bedroom 3/Bath`3 , '.'.:..
Roof
243
0.031
R-30
t
0
0 New
4.2.1-A20
Bedroom 3%Baih 3
Wall
309
0.057
R-19
4.0
None
'0
90
New
4.3.1-A5
Casita/Bath4/Bedrrn4
Wall
133
0.057
R-19
4.0
None
90
New
4.3.1-A5
CasitaBath4/Bedrm4
Wall
312
0.057
R-19
4.0
None
90
New
4.3.1-A5
Casita/Bath4/Bedrm4 .
Wall
88
0.057
R-19
4.0
None _
L270
90
New
4.3.1-A5
CasitaBath4Bedmi4Slab
535
0.730
None
180
New
4.4.7-A1
Casita/Bath4/Bedrrn4
Roof
1,543
0.031
R-30
.
0 New
4.z.1-A20 .
Casita/Bath4Bedrm4
FENESTRATION,SURFACE
DETAILS .
ID
Type
Area
U-Factor
'--SHGC
Aim-
Stafus "
' `Glaiin T ypp` . '
'Location/,Comments'''
17
Window
33.0
0.300
NFRC
0.17
NFRC
0
.New Fixed
Glass
Morning Rm/Kitchen
' 18
Window
33.0
0.300
NFRC
0.17
NFRC
90
New Fixed
Glass '.
'Morning Rm/Kitdtien
19
Window
4.5
0.300
NFRC
0.17
NFRC,
6,
New Casement
",
Bedrm2/Pwdr1Laundr3i/Qath.2 ,
20
Window
48.0
0.320
NFRC
0.30.
NFRC
0
New ' : .. `Sliding
Glass Door
Badrm21Pwdr1Laugdr pth
21
Window
1 4.5
0.300
NFRC
0.17
NFRC
1 180
New '.: Iasement
' . , ,': " ' : ;
Bedmi2/Pwdr/La0ndry/Bath,2
22
Window
4.5
0.300 1
NFRC
0.17
NFRC
180
New Casement
Bedrm2/Pwdr/Laundry/Bath`2
23 -.
Window
4.5
0.300
NFRC
0.17
NFRC
480
New Casement
:.
Bedmi2/Pwdr/Laundry1Bath2..
24
Window;
4.5
0.300
NFRC
0.17
NFRC,....
:.._.180
New Casement.
Bedrrri2/Fydr/Laui►dryBath2-'
25
Window
10.0
0.300
NFRC
0.17
NFRC
180
New Casement
Bedrm2/Pwdr/Lauridry/Bath 2
'26
Window
-4.5
0.300
NFRC
0.17
NFRC
0
New Casement
Bedroom 3/Bath 3
27
Window
1 72.0
0.320
NFRC
` 0.30
NFRC.
0
New Sliding
Glass.Door
Bedroom 3/Bath 3
28,
Window
9.0
0.300
NFRC
0.17
NFRC
..'..'0
New Casement
Casita/Bath4/Bedmi4
29
Window
9.0
0.300
NFRC
0.17
NFRC.
0
New 'Casement
Casita/Bath4/Bedrm4
30
Window
4.5
0.300
NFRC
0.17
NFRC
.0
New Casement
,
Casita/Bath4/Bedrm4 .
31
Window
4.5
0.300
NFRC
0.17
NFRC •
0
New Casement
Casita/8ath4/Bedrm4
32
Window
4.5
0.300
NFRC
0.17
NFRC
0
New Casement
Casita/Bath4/Bedrm4
(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B =.Default Table from Standards, NFRC,= Labeled Value
+
EXTERIOR
SHADING DETAILS.
ID _
'Exterior Shade Type
SHGC
Window
Ove hang
Left Fin
Rig ht Fir
H t
Wd
Len
H t
LExt
RExt
Dist
Len
'H t
Dist
Len.'
H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
'0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24 lBug
Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30 lBug
Screen
0.76
31 JBug
Screen
0.76
32 IBug
Screen
0.76
EnergyPrp 5.1 by Ene Soft User Number.• 8165 " ,` .Rt nCod6.:-2016-61-i3Tl.2:05.12 /D:'63276 : Pa a 10 of 1.5
CERTIFICATE OF COMPLIANCE:..Residential .' ;. ; .:; ..'. (Part 4 of 5� CF-1 R
Project Name
Andalusia Plan 23-8
Building Type m Single Family ❑ Addition Alone"
❑Multi Family ❑Existing+ Addition/Alteration
Date
111312015
OPAQUE SURFACE..
ETAILS
Surface
Type
Area
U-
Factor
Insulation '
Azm
Tilt
Status
Joint Appendix
4
Location/Comments
Cavity
Exterior
Frame
Interior
Frame
FENESTRATION.
SURFACE
DETAILS
ID
Type
Area
U-Factor
`,SHGC
Azm
Status
` '' Glaiin ' T 'e '"
tocatiod/Comments `
33
Window
27.5
0.300
NFRC
0.17
NFRC
90
New Sliding
Window
Casita/Bath4/Bedrm4,.,
34
Window
4.5
0.300
NFRC
0.17
NFRC
180
New Casement
Casita/Bath4/Bedrm4. '
35
Window
24.0
0.320
NFRC
0.30
NFRC
180
New , .. .French
Glass poor
Casita/Bath4/Bedrm,4
36
Window
72.0
0.320
NFRC
0.30
NFRC
270
New Sliding
Glass Door
Casita/Bath4/Bedmi4
(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC,=. Labeled Value
.,.,
EXTERIOR
SHADING, _DETAILS
ID
Exterior Shade Type
SHGC
Window
'Overhaiio
Left Fin
Right Fin
H t
Wd
Len
H t
LExt
RExt
Dist
Len
H t
Dist
Len
H t
33
Bug Screen
0.76
34
Bug Screen
0.76
35
Bug Screen
0.76
36 lBug
Screen
0.76
EnergyPro 5.1 by Ene Soft `User. Number.• 8165 , .. ' RunCode: 201$-01-13T12:03:32 : 7D: 83276 Page 11 of 15
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R
Project Name
Andalusia Plan 23-B
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1111312015
BUILDING ZONE INFORMATION:..;
System Name
Zone Name
Floor Area
Volume
Year Built
New
Existing
Altered
Removed
3 T
Great Room/Entry/Wet Bar
926
13,057
2.5 T
Master Suite
608
6,136
2 T
Morning Rm/Kitchen
609
6,151
3 T
Bedrm2/PwddLaundry/Bath 2
6911
6,979
Bedroom 3/Bath 3
243
Z449
2 T
Casita/Bath4/Bedrm4
536
5,355
Totals
3,612
0
0
0
HVAC SYSTEMS
System Name
Qty.
Heating Type '
'Min. Eft.
Coolin g'Ty a
Min. Eff.
Thermostat.T a
Status
3 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER Setback.
New `
2.5 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER Setback
.,New
2 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
17.0 SEER Setback
New
3 T
1
Split Heat Pump
8.50 HSPF
S lit Heat Pum
15.0 SEER Setback
' `
New
2 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
17.0 SEER Setback
New
HVAC DISTRIBUTION .,
System Name
Heating
Coolinq
Duct Location
Duct -
R-Value
Ducts
Tested?
Status
3 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
New
2.5 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
0
New
2 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
New
3 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.01
INew
2 T Ducted
Ducted.. ,
Attic, Ceiling Ins, vented._
B.0
.. 0
New
WATER HEATING,.SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
2
Small Gas
Kitchen Pipe Ins
40,000
50
0.59
n/a
n/a
New
MULTI-FAMILY'WATER
HEATING_DETAILS
, . _
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
ff
c
_ o
6
�a
a —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
at .
HP
Plenum
Outside
Buried
13
13
Enef gyPro 5.1 by EnergySoft User Number: 8165 .: ., .,RunCode:..2015-61-13T12:95:J2 — 1D: 63276 ' . :: , :c:i'Page 12 of 15
MANDATORY M.EAS,URES.SUM.(Pago 1 of 3 MF-1 R
Project Name
Andalusia Plan 23-8 .
Date
111312015
NOTE: Low-rise residential buildings subject to the'Standards must comply with iIl:applicable inandatory•'rneasures listed, regardless of `.
the compliance approach used. More stringent energy measures listed on the Certificate of Com,pliance'(CF 1 R,`,CF 1 R=ADD, or CF-
1 R-ALT Form) shall supersede the items marked with an asterisk (*) below.'This Mandatory Measures Summary`shall be incorporated ..
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance;:
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R
Form with . lans. :. ..
Building Enveloa Measures: ;..
116 a 1: Doors and windows between conditioned and unconditioned.s .aces are" r►lanufactured to limit air leaks e
§116(a)4: Fenestration products (except field -fabricated windows) have',label lifting the certif U Fact6Y certified Solar Heat. Gain
Coefficient SHGC , and infiltration ;that meets the r.e-rernents.of 10-111, a
117: Exterior doors and windows are weather-stripped; all 'ornts.and enetrationsare,caulked and sealed..
118 a : Insulations ecified or.installed meets Standards for li6suiating Material .indicate type. arid'indude=on CF-6R f=oim
§118(i): The thermal emittance and solar reflectance°values: of the cool roofing material meets;the requirements of`§118(i) when,the
installation of a Cool Roof is specified on the CF-.1 R Form..
*§150 a : Minimum R-19 insulation in wood -frame. ceiling ore uivalent U-factor.._
150 b : Loose fill insulation shall conform with manufacturer's installed.desi n labeled R-Value.
*§150 c : Minimum R-13 insulation in wood -frame wall or. e uivalent.t)-factor.
*§150 d : Minimum R-13 insulation in raised wood-frame,floor.,or a uivaleht U7factor_
1 50:Air retarding wrap is tested, labeled, and installed accordin to ASTM E1.6Z7 95 2000 when 5 ecified on'the.CF-iR Form.•'-
150 : Mandatory Va or barrier installed in Climate Zones 14,or 1,6... -. .. -.
§150(I): Water absorption rate for slab edge insulation material alone without facings is no,greater;than 0 8% water vapor.'permeance
rate is no rester than 2.0. erm/ini:h, and shall be rotected. from. `h `sical dams and U ..li ..light deterioration
Fireplaces, DecQrative'Gas A 'liances `and Gas Lo Measures:`,
150 e 1 A: Mason or facto�-built fire laces have a closable metal or; 'fass"door eavenri the entire o enin of the firebox
§150(e)l B: Masonry or factory -built fireplaces have a. ombustion outside air intake; whichis at least six squ `- i'mches in area and is
- .
equipped with a with .a resell. accessible, o erable, and.ti `ht-fittin dam r and'.or a'corrtbustion-air contr"ol.device...
§150(e)2: Continuous burning pilot lights and the use of indoor. adfor cooling a f�rebox�acket when that indoor air'is'vented`to the
outside of the building, are prohioJited. ;
Space Conditionin° Water.Heatin and P�umbm S stem, Measures:: t
•§110-§113: HVAC equipment, water heaters, showerheads', faucets and all other regulated appliances'are certified by the`Ener'gy'
Commission.
§113(c)5: Water heating recirculation loops servi fC;,muitiple dwelling units and:High=Rise residential occupancie-s:meet"the air, release.'
valve, backflow, prevention, um isolationmalve., and recirculation loo` conn6c: ion_re uirenienfs of 1.13 c 5.
§115: Continuously burning pilot lights are prohibited for natural gas; fah hype central furnaces household'cookmg'appliances
' (appliances with an electrical supply voltage connection with pilot lights that consume lessthan 157] Btulhr are exempt), and pool' and
spa heaters.
150 h : Heating and/or cooling loads are calculated in, accordance with ASHRAE, SMACNA or,ACCA.
150 i : Heating systems are equipped, with thermostats that meet the setback re. uirements of Section 112 c
§1500)1 A: Storage gas water heaters rated with an Energy'Factor no greater than.the federal muilrimal standard are'exterr!Mly wrapped
,.
with insulation havingan installed thermal resistance of R-.12,6r' rester
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -(heating systems or r i othendirect hot Water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value-is'indicated on tFie ezte*rior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater,tank,. non -recirculating systems, and -entire length of
recirculating sections of hot water pipes.are insulated per.%ndards
§1500)2: Cooling system piping (suction, chilled water, or'bnne lines) acid piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B-and.S uation 150-A..;..,_•;.
§1500)2: Pipe insulation for steam hydronic`heating systems or hot water,systerns i15 psi, meets''the-require ments of Standards Table
123-A.
150 ' 3A: Insulation is protected from damage, including that due,to sunlight, moisture, equipment maintenance,,and wind..:..{ .. .
§1500)3A: Insulation for chilled water piping and refrigerant suction`lines includes a vapor's""etardant or is efid6sb&britirely in
conditioned space.
150 ' 4: Solar water -heating systems and/or collectors. are certified by the Solar Ratin and Certification Cor , .ration.
EnergyPro 5.1 by EnergySoR . User, Number,..8165 , „ RunCode:. 2.01$-01 13T13 05:32 1p: 63216 Page 13 of 15 _, ` .
MANDATORY. MEASURES -SUMMARY, Residential . , Pa e 2 of 3 MF-1 R
Project Name
Date
Andalusia Plan 23-8
111312015
§150(m)1: All air -distribution system ducts arid plenums.'in stalled, a're sealed and insulatedto meet the regwreme6ts of CIVIC Sections .• ,
601, 602, 603, 604, 605 and Standard 6-5; supplyair and return=air ducts"And_pleriums are rnsuII ted to'a minirnum`mstalled level of R-
.;
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic; tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requ'rremen s of UL 723. If mastic or, *' e", s
used to seal open ins, reater than 1/4 inch,. the combination ,of mastic and _either.mesh. or tope' •shall be used
§150(m)1: Building cavities, support platforms for air handlers and,pleums defined or constructed with: materials otherthan sealed
sheet metal, duct board or flexible duct shall nottie used for conveying `conditioned:air. Building cavities and support platforms may
'platforms
contain ducts. Ducts installed in cavities and support Shall not be compressed to cause reductions"In the cross-sectiori4farea.
of the ducts. .
§150(m)2D: Joints and seams of "duct •systems and. their components shall not be'sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with,mastic and draw bands ;
150 m 7: Exhaust fans stems. have back draft or:automatic dampers ,.. .
§150(m)8: Gravity ventilating"systems °serving conditioned space hai ve eithe'rautomatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected feom;damage 'including that due to sunlight, moisture; equipment.rnainteriance "and wind. = :.
Cellular foam insulation shall be protected as above or'paihted with a coating that is wate.r retardant. provides, shielding from solar
radiation that can cause deg radation of the. material:.
150 m 10: Flexible ducts, cannot have porous inner cores::
§150(o): All dwelling units shall meet'the requirements of ANSI/ASHRAE $tan(lard 62 2-20071fentilationand Acceptable' Indoor Air
Quality in Low -Rise Residential Building : lN sindow.operat on is not a perrriiss 6le,mefhod of providWhole
ing the $uilding' Ventilation '
re uired in Section 4 of1hat Standard.
Pool and Spa Heating S E ui me7tMeasures '
§114(a): Any pool or spa heating system shall be certified to have 61hermal efficiency that complies With the Appliance ;E,ffid6ncy'
Regulations; an on -off switch mounted outside of the heater'"a,permanenf weafherproof,plate or card with. operat'ing'instructions; and
shall not use electric resistance. heating .or a pilot light.'
§114(b)l : Any pool or spa "heating equipment shall be instalied -wit "at least 96" of pipe between filter'MO heater,'or dedicated suction
and return lines, or built-up connections foe future solar. heatin . '
114 b 2: Outdoor pools ors as that,have a ;heat um of as heater'shall have a cover..
§114(b)3: Pools shall have directional inlets that adequately mix the,pool water, and a time switch'that will allow all'purnps to beset or " "
programmed to run only during off- eak electric demand eridds. ; '.
§150 :Residential poql systems :ore . ui ment ..meet the um sizin; `, flow rate, ' i in ;filters; and valve_re Lirements of §150
Residential. Li htin
§150(k)l : High efficacy'luminaires or LED Light Engine`with integral Heat`Sink.has an - fficacy'that is nolower than the efficacies
contained in Table 150-C and is not a low efficac .luminaire. as s ecified by § 1'50 k 2.
150 k 3: The wattage of permanently installed luminaires shall be determined as soecified. b .' 130(d.).
§150(k)4: Ballasts for fluorescent lamps rated13 Watts or'g"reater'shall be electronic and shall have an output'fregoency no le§s than•'
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to,a,_permanently installed luminaire.or.ezhaustfan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C .and shall not contain a line'vdttage socket or line
voltage lamp holder; OR shall be rated to consume do more than five watts of power as determined by §130(d), and shall riot contain 'a
medium screw -base socket.
150 k 6: Lighting integral to exhaust fans, in rooms other,than kitchens, shall:.meet the applicable requirements of 1.50 k .
150 k 7: All switching devices and controls shall meet the re, uirements of §150(k)7...
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be'high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100. watts for dwelling units larger than 2,500 ft2 may be. ,.
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled.by a manual on occupant.
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all periiianently ins'tatled '
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets,shall use'no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro5.1 by EnergySoff User Nymber 8165 :'tunCode:.2015-01 13T12 05 32 ID: 63276 Page 14 of 18
MANDATORY MEASURES SUMMARY; Residential Pa e 3 of
Project Name
Date
Andalusia Plan 23-8
111312015
§150(k)l0: Permanently'installed luminaires in bathrooms; attached and detached garages;'laundry rooms; closets and utility rooms __
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires'located in rooms or areas other than _in kitchens, bathrooms,, garages; laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1• Peem.ahently insta1letl low efficacy Iurriinaires'shall be'. t`
allowed provided they are controlled by either a dimmer switch that complies with the applicable regwrements of §119•,or by a malanu
on occupant sensor that complies with the.applicable requirements of §119. EXCEPTION.2 Lighti' in-detached'sioragebuilding"less .
than 1000 square feet located on. a. residential.site.is not re, wired to coin L .with : 150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings' §hall belisted for zero clearance ini A on',contact .(IC),by Underwriters ;
Laboratories or other nationally recognized testing/rating laboratory; _and have a Tabei that certifies, the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and'be'sealed with a'gasket or caulk between
the luminaire housing and ceiling..
§150(k)13: Luminaires providing outdoor lighting; including lighting"for private patios-inlow="rise residential,buildings`with four or,mpre
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed.provtded that ;
they are controlled by a manual on/off switch, a motion sensor not having an override•orbypass"switch fha3 disables the motion sensor, '.
and one of the following controls: a photocontrol not having an override or bypass switch.that disables'the photocontrol; Ok' "' ..
astronomical time clock not having an override or bypass switch that disables the, astronomical time clock; 6A an energy management ,
control system (EMCS) not having an over or bypass switch that allows the iuminaire to be always on'EXCEPTION 2: Outdoor ;
luminaires used to comply with Exception to §150(k)13 may be controlled by a temporary override, switch which bypassesrthe'motinn
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3 Permanentl'y installed
luminaires in or around swimming pool, water features, or other location subject to Article680 of the Califorrna'Electric Code need not `
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a`screw=base socket, and bonsume no
more than five wafts of.power as determined according to §130.d .
§150(k)15: Lighting for parking lots and carports'with..a total ' fo) 8 or more.vehicles per'sitesha0 Comply with the,applicable ,
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for`8 or more ve--icles §'hall corriplywith the applicable
re uirements of Sections.130,.131., 134,, and 146.. .
§150(k)16: Permanently installed lighting'in the enclosed, non -dwelling spaces`of low-rise residential bui.ldings'with four or more "
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy'Iuminaies shall be: allowed provided
p
that the are controlled b an occupant sensors certified to.com I with the applicable re uiiements of 11`J.
EnergyPro 5.1 by EnergySoft User Number.•. $165..• Runcode: 2Q15-01 19T12 05r32 ID: 63276 Page 15 of 15
BUILDING ENERGY:ANALYSi,S :REPORT„
PROJECT:
Andalusia Plan 23C
Coral Mountains 75' Lots '
La Quinta, CA �..
Project Designer:
Pekarek-Crandell., Inc
'31411 Camino Capistrano
San Juan Capistrano, CA 92675
949.487:2320
Report Prepared by: ,
x Gangyi Zhou
GMEP. Engineers • w
4400 Campus Drive
Newport Beach, CA 92660 `
Job Number: •
63276
Date:
1 /13/2015
t,
The EnergyPro computer program has been.used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program -developed by EnergySoft, LLC - www.ehergysoft.com. r
Ene Pro 5.1 b Ene Soft User Number. 1.65 RunCoo'ez 2015-01=13Tl2s04 31,.. . 'ID 63276 c x:
EnergyPro 5.1 by EnergySoft Job Number: ID: 63276 User Number: 8165
PERFORMANCE.CE.RTIFICATE:.Resiclential:. Part 1 of 5
CF-1 R
Project Name
Andalusia Plan 23C
Building Type 0 Single. Fa0hily 0 Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111312015
Project Address
Coral Mountains 75' Lots La, Quinta
California Energy Climate Zone
CA Climate Zone 1.5 ..
Total Cond. Floor Area
.. , ...3, 612
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY!CHECKLIST
El Yes ❑ No HERS Measures -- If Yes, A CF-413 must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see. Part 2 of 5 of this form for details.
INSULATION
Construction ..Type ...
Area Special
Cavity. (fi) Features see.Part 2 of 5
Status
Wall Wood Framed R-19 2,990 Ext=R-4.0
New
Slab Unheated Slab -on -Grade None 3,612 Perim = 430'
New
Roof Wood Framed Attic R-30 4,619 Radiant Barrier
New
FENESTRATION U- Exterior
Orientation .Area( Factor SHGC . Overhang Sidefins _. Shades
Status_ . .
Front (N) 41.0 0.300 0.17 none none Bug Screen
New
Front (N) 27.5 0.300 0.17 12.0 none Bug Screen
New
Front (N) 17.5 0.300 0.17 none none Bug Screen
New
Left (E) 144.0 0.320 0.30 12.0 none Bug Screen
New
Left (E) 30.3 0.320 0.30 2.6 none Bug Screen
New
Right (W) 192.0 0.320 0.30 15.0 none Bug Screen
New
Right (W) 38.5 0.300 0.17 9.0 none Bug Screen
New
Rear (S) 16.5 0.300 0.17 none none Bug Screen
New
Rear (S) 85.5 0.300 0.17 none none Bug Screen
New
Right (Kq 24.0 0.320 0.30 9.0 none Bug Screen
New
Right (149 57.0 0.300 0.17 1.0 none Bug Screen
New
HVAC SYSTEMS
City. Heating Min. Eff
Coolie Min. Eff _.; . Thermostat ,
Status
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback
New
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 15.0 SEER Setback
New
1 Split Heat Pump 8.50 HSPF
Split Heat Pump 17.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct. Location.,.,, ... - , , - ,R .Value..:
Status, ;.
3 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
2.5 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
2 T Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
WATER HEATING
Ot . Type Gallons Min. Eff....Distribution.
Status
2 Small Gas 50
0.58 Kitchen Pipe Ins
New
EnergyPro 5.1 by Ene Soft 'User Numbee-6l65. . ;: , : RunCode.. 2015-01-,13T12:04:31 1D: 63276
°.Pa e3of15,
PERFOWAN,c-E'.. 'EATIFICAtt: 'Ap4l'! n""I
C- 6 Up (Part .1
A CF -1 R
Project Name
Andalusia Plan 23C
Building Type 0 Single Famlly� U Addition Aloh6�
13 Multi Family 0 Existing+ Addition/Alteration
Date
111312015
Project Address
Coral Mountains 75'Lots La Quinta.
— -1.1, � �
California Energy Climate Zone
one
z .]
Total Cond. Floor Area
t:.. q,61
Addition
n1a
of Stories
1.
FIELD INSPP-CYION'EN-E'RGY'CH*'ECK-LISIF
El Yes 0 No HERS Measures If Yes, A CF-4R must be provided.per Part 2 of 5 of this form.
-E) Yes 0 No Special Features If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Constructign...-Type. Ily (ft). FeatUrP4 (see. t.g.,of 5) Status_
FENESTRATION U- Exterior
Orientation Arpa(ft) _fcapt9r., PWefin!$, S�aqes .Status
Left (E) 33.0 0.300 0.17 none none Bug Screen New
Front (N) 40.5 0.300 0.17 none none Bug Screen New
Front (N) 120.0 O�320 0.30 none none Bug Screen New
Left (E) 27.5 0.300 0.17 none none Bug Screen New
Rear (S) 24.0 0.320 0.30 4.0 none Bug Screen Now
Right (Kq 72.0' 0.320 0.30 none none Bug Screen New
HVAC SYSTEMS
Oty. Heating Min. Eff .Coofflng Min. Eff Thermostat Status.
I - Split Heat Pump 8.50 HSPF Split Heat Pump 15.0 SEER Setback New
1 Split Heat Pump 8.50 HSPF Split Heat Pump 17. 0 SEER Setback New
HVAC DISTRIBUTIOU Duct
Location Heating Cooling DuctLocc
3 T Ducted Ducted Attic, Ceiling Ins, vented 8.0 New
2 T Ducted Ducted Attic, Ceiling Ins, vented 8.0 New
WATER HEATING
Oty. Type Gallons Mip.,Eff Status
En e rgyPro 5. 1 b� En 6 6&S dft -.'.'-tJq i AN ffibk. 816 5 n C o cW 2 0 15 - 01. 3 �tf 2:64, ID:
Page 4 of 15
PERFORMANCE CERTIFICATE:: Rersdentiaf Part 2. of 5.) CF-1 R .
Project Name
Andalusia Plan 23C
Building Type ® Single Family '0 Addition Alone * `" '
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111312015
SPECIAL FEATURES INSPECTIOk' kE'-CKLIST "
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the s ecial •ustification and documentation submitted.._.
Compliance for all orientationeis specified; see''sectio'ri 151 (c) 2 of the Standards and `section`7.6.2 of'the Resi ential Compliance Manual.
The Roof R-30 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix RA4.2.2..
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form pr each of. the measures, listed below for final to be., iven.
The Cooling System 3 T includes credit fora 12.5 EER Condenser A 66dified'HERS rater must field verify the"installation of the correct Condenser.' '
The HVAC System 3 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 3 T includes credit for verified adequate airflow. A certified HERS'rater must diagnostically measure airflow of the HVAC System.
The HVAC System 3 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specked criteria.
The Cooling System 2.5 T includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 2.5 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used' HERS field verification is required.
The HVAC System 2.5 T includes credit for verified adequate ain9ow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 2.5 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System 2 T includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct"Condenser.'
The HVAC System 2 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Ene Pro 5. 1.by Ene SoR User Numtier 8185 ..:unCode: 2015-1)1-1. T12:04:31 "'" fD 6327(i " :. Pa e 6 of 15,
PERFORMANCE CERTIFICATE Residential, (part. 2. of.5). CF'1 R
Project Name
Andalusia Plan 23P,.., ,, ...
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1/13/2015
SPECIAL FEATURESVINSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification, and documentation submitted.,, :.. .
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R-,form for each of.1he. measures listed ,below for final -to. be g iven,-
Compliance credit for quality installation'ofinsulation has been used. HERS field ve"ncatioii is quired.
The HVAC System 2 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 2 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
The Cooling System 3 T includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 3 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 3 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
The HVAC System 3 T incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage
meets the specified criteria.
The Cooling System 2 T includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.
The HVAC System 2 T includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System 2 T includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.
EnergyPro 5.1 by Ene .Soft bserNumber�.`8165 RunCode' 2015-01-13T12:04: `!":46: 63276. :Pa e 6 of 15
PERFORMANCE CERTIFICATE .: Residential (Part 2 of 5) CF-1 13,
Project Name
Andalusia Pian.23C .
Building Type ® Single Family ❑ Addition Alone ` -
❑ Multi Family ❑ Existing+Addition/Al tera tion
Date
111312015
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the s ecial.'ustification and, documentation submitted. ,
e
HERS REQUIRED. VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must -receive a
,completed CF=4R form, for.each of the,measures listed..below_fpr finalao be, -given..,,
The HVAC System 2 T'incorpbi*es-NERS verified Duct Leakage:`PIERS field venftcatroti and diagnostic testing fs required to verify that duct leakage' y
meets the specified criteria.
Erie Pro 5.1 by Ene Soft UserNumber..8165 . °RunCode: 2015-01-13T12'04:31 :' (D: 63276 '. ; °r r.: ':~::' ..:« ".z: ' Pa e 7 of 15
PERFORMANCE CERTIFICATE A' ' "d nfial_ .(Part 3 of 5) : CFA R.
Project Name
Building Type 0 Single Family ❑ Addition Alone
Date
Andalusia Plan 23C
❑ Multi Family ❑ Existing+ Addition/Alteration
1111312015
ANNUAL ENERGY�USE SUMMARY
Standard Facing Margin - Facing Margin Facing Margin 'Facing. Margin
TDV kBtu/ft2- r North East South West
Space Heating 4.58 4.43 0.14 4.20 0.38 3.44 1.14 4.20 0.38
Space Cooling 56.64 40.78 15.86 41.37 15.28 41.55 15.09 42.02 14.62
Fans 11.40 10.92 0.48 11.06 0.34 11.12 0.28 11.21 0.19
Domestic Hot Water 10.10 12.91 -2.81 12.91 -2.81 12.91 -2.81 12.91 -2.81
Pumps 0.00 0.00 0.00 0.00 .0.00 0.00 0.00 0.00 0.00
Totals 82.72 69.04 13.67 69.53 .13.19 69.01 13.71 70.33 12.39
Percent Better Than Standard: 16.5 % 15.9.% 16.6 %. 15.0 %
BUILDING,. COMPLIES HERS VERIFICATIyON REQU1:RED.
Fenestration
Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (N) 1,370 247
Fuel Available at Site: Natural Gas (E) 586 235
Raised Floor Area: 0 (S) 1,295 126
Slab on Grade Area: 3,612 (W) 730 384
Average Ceiling Height: .11.1 Roof 4,619 0
Fenestration Average U-Factor: 0.31 TOTAL: 991
Average SHOO:-- ...: 0.2.4. Fenestration/.CFA Ratio:, . 27.4.
REMARKS :..:
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company GMEP Engineers
111312015
Address p us 4400 Cam Drive i Zhou
Name Gan 9Y
City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone Si ned Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in,this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using: duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Pekarek-Crandell,lnc
Address 31411 Camino Capistrano Name
City/State/Zip San Juan Capistrano, CA 92675 Phone 949.487.2320 Signed License # Date
1Ener-qYPro5.1bYEner-qySofi
..
User Numtier.`8165;;',:;RunCode 7015-01-13T12r04:31�"; alD; 63276 � ._ Pae 8 of 15
CERTIFICATE OP COMPLIANC :.:vResidential (Part 4. of 5). , CP-1 R ,
Project Name
Andalusia Plan 23C
Building Type m Single Family: 0 Addition Alone"
11Multi Family ❑ Existing+ Addition/Alteration
Date'
111312015
OPAQUE SURFACE
DETAILS .,;. ,..:.;•
Surface
Type
Area
U-
I Factor
Insulation
Azm
Tilt
Status
Joint Appendix
, 4.
'
Location/Comments
Cavit
Exterior
I Frame
Interior
Frame
Wall
347
0.057
R-19
4.0
None
0
90
New ,
4.3.1-A5
Great Room/En/Wet Be
Wall
92
0.057
R-19
4.0 -
None
90
90
New
4.3.1-A5
Great Room/En /Wet Ba
Wall
60
0.057
R-19
4.0
None
270
90
New
4.3.1-A5
Great Room/Ent/Wet Ba
Slab
926
0.730
None
0
'180
New '
4.4.7-A1
Great Room/Entry/Wet Be
Roof '
926
0.031
R-30
0
0 New :
4.2.1-A20
Great Room/Entry/Wet Ba
Wall
1201
0.057
R-19
4.0
None
0
90
New, . •
4.3.1-A5
Master Suite
Wall
310
0.057
R-19
4.0
None
180
90
New
4.3.1-A5
Master Suite
Wall
199
0.057
R-19
4.0
None
270
90
New.
4.3.1-A5
Master Suite
Slab
608
0.730
None
0
180
1 New
4.4.7-A1
Master Suite
Roof
608
0.031
R-30
0
0 New.
4.2.1-A20
Master Suite
Wall
87
0.057
R-19
4.0
None
0
90
New
4.3.1-A5
Moming Room/Kitchen
Wall
1351
0.057
R-19
4.0
None
180
90
New.
4.3.1-A5
Morning Room/Kitchen `
Wall
67
0.057
R-19
4.0
None'
90
90
New
4.3.1-A5
Morning Room/Kitchen
Slab
609
0.730
None
0
180
New
4.4.7-A1
Morning RooMKitche.R
Roof
609
0.031
R-30
-
0
0 New
4.2.1-A20
Moming RoomlKitchen
Wall
261
0.057
R-19 ...
4.0 , ,
None
A
.90
New
4.'3.1-AS,V
: t3edmi2(Bedmi 31Powder
FENESTRATION..
SURFAC.E-DETAIL$
... `:
ID
Type
Area
U-Factor
'SHGC
Azm."
Status
"Glazin T.
Location/Comments
1
Window
4.0
0.300
NFRC
0.17.
NFRC
0
New Fixed
Glass
Great RoomlEntry/Wet Bar
2
Window
4.0
0.300
NFRC
0.17
NFRC
0
New _ Fixed
Glass.. ;
Great Room/Entry/Wet,Bar .
3
Window
27.5
0.300
NFRC
0:11
NFRC
Q
New. `� :Casement`
.
Great Rog Fnt 1y!et8ar ..
4
Window
17.5
0.300
NFRC
0.17
NFRC. ;
. 0
New " ;' " Single
Hung `
Great Room/Britry/i!Vef Bar "` ,
5
Window
144.0
0.320
NFRC '
0.30
NFRC
.:: ,.90
New. " = 'Sliding'Glass
Door ; ;
Great Roo
6
Window
30.3
0.320 1
NFRC _..
'. 0:30
NFRC
90
New . -French
Glass Door .. :
Great'RoOm► Entr N t Bar
7
Window
192.0
0.320
NFRC''
0.30.
NFRC
:270
New `sliding
Qlass.Dqor,,1,
et;Bar .,
8
Window
38.5
0.300
NFRC
0.17
NFRC .
270.
New :' Ca
en semt, `" . `."
Great Rboftilt rylWet;Bar
9
Window
16.5
0.300
NFRC
:0.17
NF
180
New Fixed
Glass
Master'Suite '
'10
Window
16.5
0.300
NFRC
0.17
NFRC
. 180.,New.
Casement
Master Suite
11
Window
16.5
0.300
NFRC
' 0.17
NFRC
180
,New Casement
:
Master Suite
12
Window
4.5
0.300
NFRC
.0. 17
NFRC
180
New Casement
Master Suite,
13
Window
16.5
0.300
NFRC
0:17
NFRC
180
New' ':Casement'.`
Master Suite' _
14
Window
24.0
0.320
NFRC
0.30
NFRC
270
New French
Glass�Door . ,. :.Master,Suite
'
15
Window
57.0
0.300
NFRC
0.17
NFRC
270
New Fixed
Glass
Master Suite
16
Window
33.0
0.300
NFRC
0.17
NFRC
DI
New , ., Fixed
Glass
Morning Room/Kitchen
(1) U-Factor Type:. 116-A = Default Table from Standards, NFRC ='Labeled'Value
2 SHGC Type:_... 1.76 B =,Default Table from Standards, NFRC -Labeled .Value
EXTERIOR
SHADING -.DETAILS
ID
Exterior Shade Type
SHGC
Window
Overhang '
'LeftFin `
Ri ht Fin `
H t
Wd
Len..
H. t
LExt.
I RExL
Dist
Len .
H t
Dist
Len
H` t
1
Bug Screen
0.76
2
Bug Screen
0.76 .
3
Bug Screen
0.76
5.5
5.0
12.0
0.1
2.0
2.0
4
Bug Screen
0.76
5 lBug
Screen
0.76
12.0
12.0
12.0
0.1
2.0
2.0
6
Bug Screen
0.76
8.0
4.0
2.6
0.11
2.0
2.0
7
Bug Screen
0.76
12.0
16.0
15.0
0.1
2.0
2.0
8
Bug Screen
0.76
7.0
5.5
9.0
0.1
2.0
2.0
9
Bug Screen
• 0.76
r
10
Bug Screen
0.76
11
Bug Screen
'0. 76
`
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
&0
3.0
9.0
0.1
2.0
2.0
15
Bug Screen.
0.76
8.0
7.1
1.0
0.1
2.0
2.0
16
Bug Screen
0.76
Ene Pro 5.1 b Erie Soft .. User Number.8165: . >: R nCode' 201_"r01-13T12r04:31 .' .fD: 63276 -.Pa e 9 of 15
CERTIFICATE OF COMPLIANCE Residential (Part 4 of 5)" ..... CF-1 R
Project Name
Andalusia Plan 23C
Building Type 0 Single Famly ' 0 Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
-Date '
1/13/2015
OPAQUE SURFACE
DETAILS
Surface
Type
Area
U-
Factor
Insulation
Azm.
,Tilt
;s
Status
Joint Appendix "
W. 4.
Location/Comments
Cavity
Exterior
Frame
Interior
Frame
Wall
413
0.057
R-19
4.0
None
180
90
New
4.3.1-A5'
Bedrm2%Bedim 3/Powder/
Wall
60
0.057
R-19
4.0
None
90
90
New •
4.3. i-A5
Bedrm2/Bedrm 3/Powder/
Slab
934
0.730
None
0
180
New
4.4.7-A1
Bedr7n2/Bedrm 3/Powder/
Roof
9341
0.031
R-30
0
0 New
4.2.1-A20 -'
Bedrm2/Bedrm 3/Powder/
Wall
309
0.057
R-19
4.0
None'
0
90
New
4.3.1-A5
Casita/Bath4/Bedrm4 .
Wall
133
0.057
R-19
4.0
None
90
90
New :
4.3.1-A5,
Casita/8ath4/Bedrm4
Wall
312
0.057
R-19
4.0
None
180
90
New
4.3.1-A5
Casita/Bath4l!30 ►4
Wall
88
0.057
R49
4.0
None
270
90
New :.
4.3.1-A5
Casita/Bath4/8edrrri4 ,
Slab
536
0.730
None
0
180
New
4.4.7-A1
Casita/Bath4/Bedrn►4 .. _
Roof
1,543
0.031
R-30
0
0 New
4.2.1-A20
Casita/Bath4/Bedrm4
FENESTRATION
SURFACE
DETAILS .
ID
Type
Area'
U-Factor-
"..' 'SHGC
Azm'
`Status '
`. Glazin 'T a
"Location/Comni4hts
17
Window
33.0
0.300
NFRC
0.17
NFRC
90
New Fixed
Glass
Moming Room/Kitchen"' ;t ',, •;
18
Window
4.5
0.300,
NFRC
'0. t7
NFRC '. "
'
0
New Casement
..
BedrM2/Bedrm,;3/Powder/Laun
19
Window.
48.0
0.320
NFRC
0:30
NFRC
0
New Sliding
Glass Door ..
Bedim2/Bedrm `3/Powder/Ladn
20
Window
72.0
0.320
NFRC
0.30
NFRC
0
New ' -'Sliding
Glass Door
Bedrm2/Bedmi 3/PowderlLa'
21
Window
4.5
0.300
NFRC
0 17.
NFRC
D.
New I. .. Casement'.
•.
Bedrm2/6!edriii'3/P6wdkk6un
22
Window
4.5
0.300
NFRC
0.17
NFRC
180
New . Casement
` '
Bedrm2/Bedrrh 3/Powder/Laun
23
Window
4.5
0.300
NFRC • .
0.17
NFRC
180
New Casement
'' "
Bedrm2/Bedrm 31Powder/Lau i.
24
Window
4.5
0.300
NFRC
0.17
NFRC...._
` :180
New :Casement
.1 .=.:,::;':: :
Bedrm2/Bednn:3(Powtler1Laun
25
Window
4.5
0.300
NFRC
0.17
NFRC ,
180
New Casement
6edrm2Bedrm 3/PowdedLaun
26
Window
9.0
0.300
NFRC. ;
0.17
NFRC..•
180
New ... ," • Casement.'.
; `;
$edrrn2/Bedn?f"3/Pnwder/Lawn
27
Window
9.0
0.300
NFRC,
0.17
NFRC .�
_ - 0
New.',`_ ,. 'Casement
:` " .. ;.•, :'..,''
Casita/Bath4/Bedrm4. ,.
28
Window '.
9.0
0.300
NFRC
0.17
NFRC
0
New. Casement
Casita1Bath4/8edrm4
29
Window
4:5
0.306
NFRC
0.17
NFRC
0
New Casement
C.1sity1Bath40edMn4.
30
Window
4.5
0.300
NFRC
.0. 17
NFRC
.0
New . Casement'
.
CaditaTBath-4/0e01'in`4;::'. "
31
Window
4.5
0.300
NFRC
0.17
NFRC
t0
New,_ .-_Casement
'
Casita/Batii4/Bedm74 ; ..., '
32
Window
27.5
0.300
NFRC
0.17
NFRC. _
.90
New Sliding'
'Glass -. z
Casita/BatH"edrm4 ,_`:
(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value -
2 SHGC Type: , 116--13 ="Default.Table from Standards, NFRC = labeled Value ..••`
EXTERIOR
4
SHADING,DETAILS. `
ID
Exterior Shade Type
SHGC
Window
Overhang
Left Fin ; .
'Right Fin
H t
Wd
Len .
H t ..
LExt
. RExt .
. Dist
Leh'.
. H t
Dist
Len
H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20 JBug
Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
,
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
31
Bug Screen
0.76
32 JBug
Screen
0.76
EnergyPro 5.1 by Ene Soft . User Number.• 8.7$5 -,Mm0ode': 2015141-13T12.04:31 "iD: 63276 :• �Pa a 10 of 15`
t
CERTIFICATE OF COM"PLIANCE:..Residential .. ; l,,.:' , ,:. .,(Part. 4 of_ 5) CF-1 R.
Project Name
Andalusia Plan 23C
Building Type ® Single Family '❑ Addition' Alone '
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111312015
OPAQUE SURFACE.DETAILS,
Surface
Type
Area
U-
Factor
Insulation
Azm
Tilt
Status
Joint Appendix
4
Location/Comments
Cavity
Exterior
Frame
Interior
Frame
FENESTRATION
SURFACE
DETAILS
ID
Type
Area
U-Factor
'SHGCz
kri '
Status
: -:'Glazin Type
'Location/Comments-'
33
Window
4.5
0.300
NFRC
0.17
NFRC
180
New Casement
Casita1BathVBedrm4
34
Krindow
24.0
0.320
NFRC
0.30
NFRC
180
New. ' French
Glass Door
Casita/Bath4/Bedrm4,
35
Window
72.0
0.320
NFRC
0.30
NFRC
270
New Sliding
Glass Door
Casita1Bath41Bedrrii4
(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-.B = Default.Table from.Standards, NFRC = Labeled Value_
.
EXTERIOR
SHADING.DETAILS
ID
Exterior Shade Type
SHGC
Window
Overhang'
Lett Fin
'Right Fin`
H t I
Wd
Len
H qA
LExt
I RExt
Dist
Len
H t
Dist
Len
H t
33
Bug Screen
0.76
34
Bug Screen
0.76
8.0
3.0
4.0
0.1
4.0
4.0
35
Bug Screen
0.76
Ene Pro5.1 b Ene Soft User,. Number:8165;'.::I4unCode'3015-01-13T12:04:31_. ID:63276 _ Page f1 of1.5.
CERTIFICATE'OF COMPLIANCE:. 'Residenticil ,.,. ;, ,. ; (Part 5 ,of 5), . _ -CF-1 R
Project Name
Andalusia Plan 23C .
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1/13/2015
BUILDING. ZONE INFORMATION
System Name
Zone Name
FloorArea
Volume
Year Built
New
Existinq
Altered
Removed
3 T
Great Room/Entry/Wet Bar
926
13,057
2.5 T
Master Suite
608
6,136
2 T
Morning Room/Kitchen
609
6,151
3 T
Bedmt2/Bedrm 3/Powderkaund
934
9,428
2 T
Casita/Bath4/Bedrm4
536
5,355
Totals
3,612
0
.�01
.0,
HVAC SYSTEMS
System Name
Qt .
Heating Type
Min. Eff.
'Cooling T l "
'Min.'Eff.'.
Therinostat'T. p e
Status
3 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER
Setback., :
New
2.5 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER
Setback
New.
2 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
17.0 SEER
Setback
New
3 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER
Setback
New
2 T
1
Split Heat Pump
8.50 HSPF
Split Heat Pump
17.0 SEER
Setback
'New
HVAC DISTRIBUTION—,
System Name
Heating
Cooling
Duct Location
Duct
R-Value
Ducts
Tested?
Status
3 T
Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
New
2.5 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
0
New
2 T Ducted
Ducted.
Attic, Ceiling Ins, vented
8.0
El
New
3 T Ducted
Ducted
Attic, Ceiling Ins, vented
8.0
10
New
2 T Ducted
I
Ducted
Attic, 9
Ceilin Ins, vented:.,
8.0
.:.. p , ,
New
WATER HEATING SYSTEMS
S stem Name
Qt .
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
2
Small Gas
Kitchen Pipe Ins
40,000
50
0.58
n/a
n/a
New
MULTI-FAMILYWATER
HEATING
DETAILS
HYDRONI,C
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
ff
0
id
v
¢ —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty.
HP
Plenum
Outside
Buried
13
EnergyPro 5.1 by Ene Soft User Nurriber:8105' " .` RunCode: 2015-01-13T12r04:31 dD: 63276 Page 12 of.!i5.,
MANDATORY MEASURES 'SUM MA' AV': k6Ssid4Mi4.1 0 e 1 `of .3 ` : ,;:." MF-1 R ,.
Project Name
Andalusia Plan 23C
Date -
1/13/2015
NOTE: Low-rise residential buildings subject to tlie'Standards must comply:with all app!Jc' ble mandatary measures fisted,, regardless of
the compliance approach used.. More stringent energy measures listed on the Certificate 'of Compliance::(CF tR, CF 1A-ADD or CF
1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures tummary'shafl be' incofp6 da d ..`
into the permit documents, and the a licable featuies'shaf) be considered b all stiles as minimum com onent erformance _ •... P PP y P... p P
specifications whether they are shown elsewhere In the documents or in this'summary. Submit all applicable sections of the MF-1 R
Form with plans.
Building Envelo a Measures: `
116 a 1: Doors and windows between conditioned and unconditioned spaces are._manufactured to limit air leaks e
§116(a)4: Fenestration products (except field -fabricated s) window,have a labdi'listing thie". feeed;U Factor certified Solar Hea'tGairf•- =
Coefficient SHGC , and infiltration. that meets the reuirements of 10..=111. a . . '
117: Exterior doors and windows are weather-strj ed, all bints.and netrattons-:are caulked anii sealed. -
118 a : Insulations ecified'or.installed meets'S,tandards for Insulatin Material "indicate t e and-include,ori CF-•6#'Form.'-'.,.
§118(i): The thermal emittarice grid solar reflectance "values of the cool roofing `'material meets the requirements of;§118(i)when the
installation of a Cool Roof is. specified, on the.CF-i R Form..•:. _::` ' :.," .
*§150 a : Minimum R-19 insulation in wood-frame.ceilrn 'or;e uivalent UActor - • :=: .
150 b : Loose fill insulation. shall. conform,with manufacturer's installed-desi n labeled R-.Value
*§150 c : Minimum R-13 insulation in wood -frame wall. or e" uivalent U-tactor.
*§150 d : Minimum R-13 insulation in raised wood -frame floor or a uivalent. U-factor.
150 : Air retardingwrapis tested, labeled, and. installed accordin to ASTM E1.677.95.2000 'when s ecified on the"CF-1 R Form:.. .
150 : Mandatory Vapor barrier installed in Climate Zones,l4.or..16. .•
§150(I): Water absorption rate`for slab edge insulation material along wnthout facings is no greater than 0.3% water vapor permeance
rate is no areater,than. 2.0 erm/inch:and shall be rotected- from ' h sicaf lama' e`and UV li `fit deterior`atfon
Fireplaces, Decorative.Gas `fiance " 'rid Gas log Measures: `'
150 e 1 A: Mason or facto- built'fire laces have a Closable metal or' lass door'. ` vertu` the Entire oenm of the firebiix
§150(e)1 B: Masonry oYfactorybuilt fireplaces have a combustion outside air intake; wh�ch'is at least six"square inches in ,area and is
equip ed with a with a readily accessible, operable. -And ti fit-fittin dam er and 6i'a.combustion=air Control
§150(e)2: Continuous buming pilot7ighfs'and the'use-of indoor air'for cooling a firebox jacket when that m inor alr is vertted to'the
outside of the bujl-din , are rohibited: ;
Space Conditioning; Water"Heatin anii Plumbing 'S stem Measures:' 777777
§110-§113: HVAC equipment, Water heaters, showerheads,`faucets and all other'regulated'appliances are'certifZ_d 'by the Energy'
Commission. t
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies'meet 04air release
valve, backflow prevention, purrip.isolation valve, and recirculation' loo connection re uvements of
§115: Continuously burning pilot lights are prohibitedfor natural gas: fan=type ceniral furnaces household •cook ` mgappliarices `
(appliances with an electrical supply voltage connection with pilot lights that consume less than 160 Bil are exempt), and pool and
spa heaters.
150 h : Heating and/or coolin .loads are calculated in accordance with: ASHRAE, SMACNA. or:ACCA. :
150 i : Heating systems are equipped with. thermostats that meet the setback re uirements of,Se.ction 3,i2(c
§1500)1A: Storage gas water heaters rated with an Energy Factor no great& than'the federal minimal standard are externally wrapped
with insulation havingan installed thermal resistance pf•R-12 or' rester.'
§1506)1 B: Unfired storage tanks, such as'storage tanks or backup'tariks `for solar water -heating system, or other indirect hot water'
tanks have R-12 external insulation or R=16 internal insulation where the internal insulation-R-value is'inlicated on the ekii riot of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems,. and.entire.length of
. ...
recirculatin sections of hot water. i es.are insul.ated,p er Standards Table 150-13..
§1500)2: Cooling system piping (suction, chilled water or brine Imes) and:pipmg insulated. between heating source and indirect hot
water tank shall be insulated to.Table 150-B and E,�uation.l5U A
§1500)2: Pipe insulation for steam'hydronic beating systems'or'hoi"watensystems 51`5 psi, meets the requirements of Standards Table
123=A.
150 ' 3A: Insulation is protected from. dam e, includin that due. to sunli fit, moisture, a ui merit maintenance., and wind.. ,
§1500)3A: Insulation for chilled water piping and refrigerantsuction'lines includes a vapor retardant or is'enclosed'entirdy" in
conditioned space.
150 ' 4: Solar water -heating systems and/or -collectors are certified by the Solar.RatiI49 and Certification Corporation.
EnergyPro 5.1 by EnergySoft Run�ode:.2015-01 13T12 04:31 �'.' - fD: 63276.. - .: • _ :' - Page.13 of,15.
MANDATORY.MEASUR S.SUMMARY Residential; K. ,,-: ; Pa a of 3 :: IVIFw R.
Project Name
Date
Andalusia Plan 23C 0111312015
§150(m)1: All air-distribution`system ducts and plodbiieinstalle'd are sealed and insulated'to meet the requirements of CMC Sections:
601, 602, 603, 604; 605 and Standard 6-5; supply -air and return -air ducts'and plenums"are insulated to a.minimum'installed.level of
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with .mastic, taPe or other duct -closure system ghat meets the
applicable requirements of UL 181, UL 181A, or UL.181 B or aerosol sealant that meets the. req`uirerrients'of Ul723 If mastic. or"tap0s
used to seal o enin s heater than,i/4. inch, the combination:of mastic and either mesh.,orta e-shall be used"'." '
§150(m)1: Building cavities, support platforms for airrhandlers 'and plenums defined or constructed with mdtenals pther;than sealed
sheet metal, duct board or flexible duct shall not be used for conveying condiUoned'air t3u'ilding cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions"in the cross -sectional area'`
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall.not t?e sealed'with cloth back rubber adhesive duct tapes `.
unless such tape is used in combination with mastic..and draw,bands .'"
150 m 7: Exhaust fans stems. have, back draft or_automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioners soace'have'eYdher`automatic orreadily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moistu_ re eQujpment maintenance and_wind...
Cellular foam insulation shall be protected as above or painted:with`a coating that is water retardant and: provides shielding from solar.
radiation that can cause degradation of the material. '
150 m 10: Flexible ducts cannot have. orous inner cores.
§150(0): All dwelling units shall meet the requiremen#s of ANSI/AS.HRAE Standard 62,2-2007 Ventilationand Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing''the'W ole Bwiding Ventilat on -
re uired in Section .4 of.that Standard.. _ _•.. • ._._•- .;
Pool and a Heatin S stems,and E, w mint Measures S
§114(a): Any pool or spa.lieating system §h'atl be certified to have.'a thermal efficiency;thal complies wdhahe Appliance,l=fficiency
Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or. card with operating instructions; and
shall not use electric resistance heating or a.pilot light.
114b1:An ._
§ O y pool or spa heating equipment shall be installed with_ at least 36" tw of,pipe'beeen ::#filter and heater,'or dedicated sucfion"
and return lines, or built-up connections.for ,future.solar heatin . `"` • ° `' - ° ; • ; :. `
114 b 2: Outdoorpools ors as that have a.heat pump or. as.heater.shail have a:cover.'.: ,• :.:. ;.:
§114(b)3: Pools shall have drectional inletsthat adequatelymxahe pool water and a tif' itch'that will,aflow aTl.pumps to be set or
•
programmed to run only during off- eak electric demand: .riods:
150 :Residential pooi. s stems or equipment meet the . um sizm ,flow rate,' `i m ;'filters; "and valve re uirements of §150 _ `;
:.,
Residential Lightina Measures:
§150(k)1: High efficacy"luminaires br LED Lighf'Engine`with lnW&a'il.HeM'Sirik has an efficacythat is no 10,Aidir thari'the efficacies" `
contained in Table 150-C and is not.a low efficacy I.uminaire as. specified b 1%k 2
150 k 3: The wattage of permanently installed tuminaires`shail be'det6ir ined;as;s ecified'6 130 d .
§150(k)4: Ballasts for fluorescent lamps rated'13 Watts'or greater`shah tie electronic `and shall have an output'frequency no le'ss-than `
20 kHz.
§150(k)5: Permanently installed night lights and night light§•integral'to a pernanei ri installed luminaire or :exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 1.50-C ancJ shall not d6h,6in.a line voltage socket or"line
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a"
medium screw -base socket.
150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens., shall. meet the'applicable requirements of §150(k).
150 k 7: All switching devices and controls shall meet the requirements of, 1.50, k 7.
§150(k)8: A minimum of 50 percent of th6 totaf rated wattage of permanently"installed lighting in kitchens shall be high efficacy ".: .
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,5bO ft2 or 100 watts`for dwelling units'larger than 2;500 ft2 may be•:,
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen;'are'contr`oiled by a manual on.occupant `
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms 'are `high efficacy and controlled by 'a'
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet. '
' r r
EnergyPro 5.1 by EnergySoft User Number 8165 : , RunCo�les 2015-01 13T12:04:3! ; `: ' '; dD 63276. "; Page 14 of 95
ti.
MANDATORY MEASURES. SUMMARY:, Residential., Pa e`'3 of 3 .' .MF-1 R .
Project Name
Date
Andalusia Plan 23C
1/13/2015
§150(k)10: Permanently installed luminaires in bathrooms; attached and detached garages,laundry'rooms; ciois6t"s'and utility rooms"'
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor...
§150(k)11: Permanently installed luminaires located in rooms or areas,other;than ,jn_kitcHdns, bAt;hrooms; garages,`lauridry rooms;.
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1'.`Permanently installed low efficacy luminaires $hall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable rcquiremQitts of.. 119 ofby a maniiAl-
on occupant sensor that complies with the applicable requirements of ,§l 19. EXCEPTION_2: Lighting in deta h4l storage building`less
than 1000 square feet located on. a. residential site is not ee wired to com - I _ with.: " 150 k 11.
§150(k)l2: Luminaires recessed into'insutated ceilings shafl be listed'for zero clearance insulation contact..(IC) by Und6rWr'iters
Laboratories or other nationally recognized testmgh" in laboratory; and have a label that certifies the lumiunaire is alrtight with'air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and sealed with a`gaske't or cautk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing'outdoorligliting, including lighting for private patios in. low-rise residential buildings With .f r,ormore"` '
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other, buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low.efficacy Iumnaires shall be:allowed provided;that
they are controlled by a manual on/off switch, a motion sensor not having an override. or bypass switch that disables the motion sensor, .
and one of the following controls: a photocontrol not having an override or.bypass'switch that disables ihe.phoi' 66trol;.'OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION,2: Outdoor'.
luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch wNch`bypasses 'hi 'motion:. `
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently'.installed ,
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires. .
§150(k)l4: Internally illuminated address signs shall comply witFi Section,148; OR not contain a screw=base socket, and'consume' no
more than five watts of power as determined according to, 130(d).
§150(k)15: Lighting for parking lots and carports with `a total, of for 8 or more vehicles per site `Shall comply with the. applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply "with the applicable
requirements of Sections 130, 131, 134,, and 146.. ..
§150(k)16: Permanently installed lighting inthe enclosed, non=dwelling spaces of low rise residential buildings with;four or more .
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently.installed,low efficacy luminaires shall tie allowed provided
that the are controlled b an occupant sensors certified to comply� with the a .. licable re.uirements
EnergyPro 5.1 by EnergySoft User Number'.8165 , .r. RunCode: 2015-01=13T12 04'3,{ .. iD: 63276 . , . Page 15 of 15