Codorniz TR 32070 BTCP2017-0010 (Plans 1, 2, 2X, & 3) 2016 Code Update - Title 24CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name: Codorniz Plan - SF1 Cassia Calculation Date/Time: 19:40, Fri, Dec 15, 2017 Page 1 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-1 Cassia - Revised 12-14-17.ribd16x
GENERAL INFORMATION
01
Project Name
Codorniz Plan - SF1 Cassia
02
Calculation Description
Title 24 Analysis
03
Project Location
Avenue 52 and Jefferson Street
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.2.1 (695)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.1
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
1250
15
Number of Zones
1
16
Slab Area (ft2)
647
.17
Number of Stories
2
18
Addition Cond. Floor Area
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ft2)
n/a
21
Glazing Percentage (%)
22.4%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance-
02
t c 'mot' F i d. M "'+===ti M t_ :f1 �� h K 4 Y"�. �..a.y-'•-
This building incorporates features that r*&quire field testing-and/orlvenfication bya certified HERS rate- under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Featu es shown below
t� This compliance analysis 14valid only for permit;applications th ough.October 24,f2017
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE 11mazapm Ll
Registration Number: 217-P010290052B-000-000-0000000-0000 Registration DatefTime: 2017-12-18 09:41:44
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
COIU►CITY OFMUNITy LA QUpgTA
DEVELOPMENT
HERS Provider: Ca in
Report Generated at: 2017-12-15 19.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF1 Cassia Calculation Date/Time: 19:40, Fri, Dec 15, 2017 Page 2 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-1 Cassia - Revised 12-14-17.ribdl6x
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.64 2.12
-0.48
-29.3%
Space Cooling
• 113.23 97.04
16.19
14.3%
IAQ Ventilation
1.56 1.56
0.00
0.0%
Water Heating
9.88 8.62
1.26
12.8%
PV Credit
--- 0.00
0.00
---
North Facing Compliance Total 126.31 109.34
16.97
13.4%
Space Heating
1.64 2.19
-0.55
-33.5%
Space Cooling
113.23 106.65
6.58
5.8%
IAQ Ventilation
1.56 1.56
0.00
0.0%
Water Heating
9.88 8.62
1.26
12.8%
PV Credit
---- 0.00
0.00
---
East Facing Compliance Total- f------ 126.31 119.02
7.29
5.8%
Space Heating
Space Cooling
'_� T''" 1.64 1.70
11.3.23 96.33
-0.06
16.90
-3.7%
14.9%
IAQ Ventilation
15, 156
E-
Inc..
0.00
0.0%
Water Heating
_
�t9.88C n 8 2;
1.26
12.8%
PV Credit
-- S 0`00 I
0.00
South Facing Compliance Total 126.31 108.21
18.10
14.3%
Space Heating
1.64 2.03
-0.39
-23.8%
Space Cooling
113.23 108.15
5.08
4.5%
IAQ Ventilation
1.56 1.56
0.00
0.0%
Water Heating
9.88 8.62
1.26
12.8%
PV Credit
-- 0.00
0.00
--
West Facing Compliance Total 126.31 120.36
5.95
4.7%
FA
Registration Number: 217-P010290052B-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:41:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 19:41:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF1 Cassia Calculation Date/Time: 19:40, Fri, Dec 15, 2017 Page 3 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-1 Cassia - Revised 12-14-17.ribdl6x
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generationto"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV
Final EDR of Proposed Design
North
56.3
51.4
0.0
51.4
East
56.3
54.2
0.0
54.2
South
56.3 jy
51.0
0.0
51.0
West
56.3 ,�
54.6
0.0
54.6
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement ,for ,inrclimate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
�Single fFamily
photovoltaic (PV) renewable energy generation sufficient toachieve-a Final Energy Design'Rating"(EDR) of zero of less. The PV System must be verified.
REQUIRED SPECIAL FEATURES �� L0
The following are features that must be installed as conditionMor meetinglthe�mode, led energy perto manwcRe fo this comPuteu analysis.
• Cool roof - ` -,� " ti '�?+ r .k w.r: u• �a.rr ar !e rw « w
• Insulation below roof deck
• Window overhangs and/or fins
• Exposed slab floor in conditioned zone
• Non-standard duct location (any location other than attic)
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Verified low -leakage ducts in conditioned space must meet maximum 25 cfm leakage to outside (RA3.1.4.3.8)
Domestic Hot Water System Verifications:
-- None --
Registration Number: 217-P0102900528-000-000-0000000-0000 Registration DateRme: 2017-12-18 09:41:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 19:41:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD „ CFI R-PRF-01
Project Name: Codorniz Plan - SF1 Cassia Calculation Date/Time: 19:40, Fri, Dec 15, 2017 Page 4 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-1 Cassia - Revised 12-14-17.ribdl6x
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Codorniz Plan - SF1 Cassia
1250
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
1stFloor
Conditioned
HVAC Split Systeml
1250
9
DHW Sys 1
L CE, mcv-$%
S"IDER
Registration Number: 217-P010290052B-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:41:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 19:41:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD. CF1 R-PRF-01
Project Name: Codorniz Plan - SF1 Cassia Calculation Date/Time: 19:40, Fri, Dec 15, 2017 Page 5 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-1 Cassia - Revised 12-14-17.ribdl6x
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window 8 Door Area (ft2)
Tilt (deg)
Exterior Wall Front N 7.5
1st Floor
R-13 Wall /R-5 ESP
0
Front
109
20
90
Exterior Wall Front NW 3x
1st Floor
R-13 Wall /R-5 ESP
315
specify -
30
24
90
Exterior Wall Front NE 3x
1st Floor
R-13 Wall /R-5 ESP
45
specify -
30
0
90
Exterior Wall Right W
1st Floor
R-13 Wall /R-5 ESP
270
Right
15
0
90
Exterior Wall Front N - 8
1st Floor
R-13 Wall /R-5 ESP
0
Front
143
40
90
Exterior Wall Front N - 2
1st Floor
R-13 Wall /R-5 ESP
0
Front
18
0
90
Exterior Wall Front N - 1
1st Floor
R-13 Wall /R-5 ESP
0
Front
82
7
90
Exterior Wall Left E - 18
1st Floor
R-13 Wall /R-5 ESP
90
Left
144
0
90
Exterior Wall Rear S -13x
1st Floor
R-13 Wall /R-5 ESP
180
Back
189
90
90
Exterior Wall Right W - 1
1st Floor
R-13 Wall /R-5 ESP
270
Right
194
32.5
90
Exterior Wall Right W 1.5
1st Floor
R-13 Wall /R-5 ESP
270
Right
14
0
90
Exterior Wall Front N 12.
1st Floor _
o,,R-l3 Wall /R-5 ESP _
_ 0
_ Front
114
30
90
Exterior Wall Front N 8.4
1 1st Floor �� t
aR 3 Wall/R-5,ESP�-0Fyont
75.75
15
90
Exterior Wall Left E 27.5
1 / , 1,st Floor r
'R',1'-3 Wall/R-5 ESP
r 901
Left
248
12.6
90
Exterior Wall Left E 9.9x
i 1st`F.loor(
RR 1TWA-1 l /R-S�ESP
� %90
—Left,
89.6
8
90
Exterior Wall Rear S 21x9
1st Floo A
� 11P113=Wall /R-6TESP tA t
180 I
L-0 Back
3 189
15
90
Exterior Wall Right W 10.
1st Floor
R-13 Wall /R-5 ESP
270
Right
95
10
90
Exterior Wall Right W 9.5
1st Floor
R-13 Wall /R-5 ESP
0
Front
85.5
0
90
Exterior Wall Rear S 6.5x
1 st Floor
R-13 Wall /R-5 ESP
0
Front
58.5
0
90
Exterior Wall Front N 3x9
1st Floor
R-13 Wall /R-5 ESP
0
Front
27
0
90
Interior Surface to Garag
1st Floor>>Garage_
R-13 Wall
232
17.3
1st Floor Roof
1st Floor
R-22 Roof Attic
44
2nd Floor Roof
1 st Floor
R-22 Roof Attic
603
Interior Surface 2nd Floo
1st Floor>>Garage_
R-19 Floor No Crawlspace
332
Exterior Wall Left 24.25x
Garage_
Garage Exterior Wall
90
Left
194
20
90
Exterior Wall Front 21x8
Garage_
Garage Exterior Wall
180
Back
168
128
90
Exterior Wall Right 14.5x
Garage_
Garage Exterior Wall
270
Right
116
0
90
Garage Roof
Garage_
R-0 Roof Attic
427
Registration Number: 217-P010290052B-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:41:44 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 19:41:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01
Project Name: Codorniz Plan - SF1 Cassia Calculation Date/Time: 19:40, Fri, Dec 15, 2017 Page 6 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-1 Cassia - Revised 12-14-17.ribd16x
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Garage_
Attic Garage Roof Cons
Ventilated
4
0.1
0.85
No
No
Attic 1st Floor
Attic Roof1st Floor
Unventilated
4
0.63
0.85
No
Yes
R--JR T-5
*ffi'�) C nc.
Registration Number: 217-P010290052B-000-000-0000000-0000 Registration Dateffime: 2017-12-18 09:41:44
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
A
HERS Provider: CaICERTS inc.
Report Generated at: 2017-12-15 19:41:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF1 Cassia Calculation Date/Time: 19:40, Fri, Dec 15, 2017 Page 7 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-1 Cassia - Revised 12-14-17.ribd16x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
Window 2620FG - Fen 6
Window
Exterior Wall Front N 7.5 (Front-0)
2.5
2.0
1
5.0
0.28
0.22
Insect Screen (default)
Window 2660SH - Fen 5
Window
Exterior Wall Front N 7.5 (Front-0)
2.5
6.0
1
15.0
0.30
0.20
Insect Screen (default)
Window 2660SH - Fen 7
Window
Exterior Wall Front N - 8 (Front-0)
2.5
6.0
1
15.0
0.30
0.20
Insect Screen (default)
Window 2620FG - Fen 8
Window
Exterior Wall Front N - 8 (Front-0)
2.5
2.0
1
5.0
0.28
0.22
Insect Screen (default)
Window 2660SH - Fen 9
Window
Exterior Wall Front N - 8 (Front-0)
2.5
6.0
1
15.0
0.30
0.20
Insect Screen (default)
Window 2620FG - Fen 10
Window
Exterior Wall Front N - 8 (Front-0)
2.5
2.0
1
5.0
0.28
0.22
Insect Screen (default)
Window 2036SH - Fen 11
Window
Exterior Wall Front N - 1 (Front-0)
2.0
3.5
1
7.0
0.30
0.20
Insect Screen (default)
Window 9080 SLDR - Fen 12
Window
Exterior Wall Rear S -13x (Back-180)
9.0
8.0
1
72.0
0.30
0.20
Insect Screen (default)
Window 9020FG - Fen 13
Window
Exterior Wall Rear S -13x (Back-180)
9.0
2.0
1
18.0
0.28
0.22
Insect Screen (default)
Window 2660SH - Fen 1
Window
Exterior Wall Right W - 1 (Right-270)
2.5
6.0
1
15.0
0.30
0.20
Insect Screen (default)
Window 2620FG - Fen 2
Window
Exterior Wall Right W - 1 (Right-270)
2.5
2.0
1
1 5.0
0.28
0.22
Insect Screen (default)
Window 2620FG - Fen 4
Window
ExterioaWafl--Right W 1 (•nigh 2w0��
? 2:5
2.0
# 1_
_ 5.0
0.28
0.22
Insect Screen (default)
Window 2660SH - Fen 3
Window
1 Exterio14Wall Righ �W �11,i`(Right-270 I
*C 2.51
At6.0
# 0.5
'7.5
0.30
0.20
Insect Screen (default)
Window 3050SH - Fen 16
Window
ExteriodrWall F ont NA2Font-0)** 1
111i {3011111111ii15F
0 010
*f5r0
0.30
0.20
Insect Screen (default)
Window 3050SH -Fen 17
Window
'Exterior 1Nall Fr nt N 12. (F ont-0)
3.0n
V5.0
1
R15.0
0.30
0.20
Insect Screen (default)
Window 2630FG - Fen 14
Window
Exterior Wall Front N 8.4 (Front-0)
2.5
3.0
1
7.5
0.28
0.22
Insect Screen (default)
Window 2630 FG - Fen 15
Window
Exterior Wall Front N 8.4 (Front-0)
2.5
3.0
1
7.5
0.28
0.22
Insect Screen (default)
Window 2626FG - Fen 19
Window
Exterior Wall Left E 27.5 (Left-90)
2.5
2.5
1.008
6.3
0.28
0.22
Insect Screen (default)
Window 2626FG - Fen 20
Window
Exterior Wall Left E 27.5 (Left-90)
2.5
2.5
1.008
6.3
0.28
0.22
Insect Screen (default)
Window 2040SH - Fen 18
Window
Exterior Wall Left E 9.9x (Left-90)
2.0
4.0
1
8.0
0.30
0.20
Insect Screen (default)
Window 3050SH - Fen 21,22
Window
Exterior Wall Rear S 21x9 (Back-180)
3.0
5.0
1
15.0
0.30 1
0.20
Insect Screen (default)
Window 2640SH - Fen 23
Window
Exterior Wall Right W 10. (Right-270)
2.5
4.0
1
10.0
0.30
0.20
Insect Screen (default)
Window 2640SH - Fen 24
Window
Exterior Wall Left 24.25x (Left-90)
2.5
4.0
1
10.0
0.30
0.20
Insect Screen (default)
Window 2640 SH - Fen 25
Window
Exterior Wall Left 24.25x (Left-90)
2.5
4.0
1
10.0
0.30
0.20
Insect Screen (default)
Registration Number: 217-P010290052B-000-000-0000000-0000 Registration Date[Time: 2017-12-18 09:41:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 19:41:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF1 Cassia Calculation Date/Time: 19:40, Fri, Dec 15, 2017 Page 8 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-1 Cassia - Revised 12-14-17.ribd16x
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door 3080
Exterior Wall Front NW 3x
24.0
0.50
Door 2868
Interior Surface to Garag
17.3
0.50
Garage Door 16070 OHD
Exterior Wall Front 21x8
128.0
0.70
{
Registration Number: 217-Po10290052B-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:41:44
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-12-15 19:41:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01.
Project Name: Codorniz Plan - SF1 Cassia Calculation Date/Time: 19:40, Fri, Dec 15, 2017 Page 9 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-1 Cassia - Revised 12-14-17.ribd16x
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
Window 2620FG - Fen 6
1.5
8
2
2
0
0
0
0
0
0
0
0
0
Window 2660SH - Fen 5
1.5
3
2
2
0
9.5
0
8.5
0
0
0
0
0
Window 2660SH - Fen 7
1.5
8
2
2
0
0
0
0
0
0
0
0
0
Window 2620FG - Fen 8
1.5
8
2
2
0
0
0
0
0
0
0
0
0
Window 2660SH - Fen 9
1.5
8
2
2
0
0
0
0
0
0
0
0
0
Window 2620FG - Fen 10
1.5
8
2
2
0
0
0
0
0
0
0
0
0
Window 2036SH - Fen 11
1.5
8
2
2
0
0
0
0
0
0
0
0
0
Window 9080 SLDR - Fen 12
1.5'"
4
2
2
0
0
0
0
0
14.5
0
2
0
Window 9020FG - Fen 13
1.5,"
8
2
2
0
0
0
0
0
0
0
0
0
Window 2660SH - Fen 1
1.5
' -4 "
2.-
2
0
0
0
0
0
0
0
0
0
Wndow 2620FG - Fen 2
'`� 1.5
,.�' 2 -` }
2
opw
fmolm%
wro'oft
0t
0
0
0
0
0
0
Window 2620FG - Fen 4
, 11.5%
2 1
2�
J C2
Ojme
0
0.# f
-1 C
0
0
0
0
.0
Wndow 2660SH -Fen 3
j 1.5r '
4 '
AWWWn
�IIMiE2
� 2 i
$WW0J V
0�
01 IN
V A
!M 0
0
0
0
0
dow 3050SH - Fen 16
/ 1.5
��:.;
P42
R 2
Po0
V
k onF
0R
0
0
0
0
0
Window 3050SH - Fen 17
1.5
1
2
2
0
0
0
0
0
0
0
0
0
Wndow 2630FG - Fen 14
1.5
1
2
2
0
1.5
0
2.95
0
0
0
0
0
Window 2630 FG - Fen 15
1.5
8
2
2
0
0
0
0
0
0
0
0
0
Window 2626FG - Fen 19
1.5
1
2
2
0
0
0
0
0
0
0
0
0
Window 2626FG - Fen 20
1.5
1
2
2
0
0
0
0
0
0
0
0
0
Window 2040SH - Fen 18
1.5
1
2
2
0
0
0
0
0
0
0
0
0
Window 3050SH - Fen 21,22
1.5
1
2
2
0
0
0
0
0
0
0
0
0
Window 2640SH - Fen 23
1.5
1
2
2
0
6
0
0.5
0
0
0
0
0
Registration Number: 217-Po10290052B-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:41:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 19:41:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name: Codorniz Plan - SF1 Cassia Calculation Date/Time: 19:40, Fri, Dec 15, 2017 Page 10 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-1 Cassia - Revised 12-14-17.ribdl6x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
• Inside Finish: Gypsum Board
• Cavity / Frame: R- 13 / 2x4
Garage Exterior Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.101
Exterior Finish: 3 Coat Stucco
Ceilings (below
Inside Finish: Gypsum Board
R-0 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
none
0.481
Cavity/Frame: no insul. /2x4
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Garage Roof Cons
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
t
Cavity / Frame: R-9 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof1 st Floor
Attic Roofs ,
Wood Framed Ceiling
in. O.C.
R 9
0.103
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
_
Cavity/Frame: R-13/2x4
Sheathing/Insulation: R5Sheathing
R-13 Wall /R-5 ESP
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.063
Exterior Finish: 3 Coat Stucco
Ceilings below;
y ff-"-Y
A!
Inside Finish: Gypsum Board
Cavity/Frame: R-9.1 /2x4
R-22 Roof Attic
<'- '
Framed
in.
attic)
Wood Ceiling,
2x4 @ 1_6. O:C.
$R 13
O:Q7y11
Over Ceiling Joists: R-3.9 insul.
,.
Inside Finish: Gypsum Board
• Cavity/Frame: R-13/2x4
R-13 Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.092
Other Side Finish: Gypsum Board
• Floor Surface: Carpeted
• Floor Deck: Wood Siding/sheathing/decking
• Cavity/Frame: R-19/2x6
R-19 Floor No Crawlspace
Interior Floors
Wood Framed Floor
2x6 @ 16 in. O.C.
R 19
0.048
Ceiling Below Finish: Gypsum Board
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab -on -Grade
1st Floor
307
60
None
1
No
Slab -on -Grade 2
1st Floor
340
47
None
0
No
Slab -on -Grade 3
Garage_
427
0.1
None
0
No
Registration Number: 217-P010290052B-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:41:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 19:41:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01
Project Name: Codorniz Plan - SF1 Cassia Calculation Date/Time: 19:40, Fri, Dec 15, 2017 Page 11 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-1 Cassia - Revised 12-14-17.ribdl6x
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
--
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1 (1)
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
Tank
Energy
Tank Insulation
Tank Location or
Heater
Number
Volume
Factor or .
Input
R-value
Standby Loss /
Ambient
Name
Element Type
Tank Type
of Units
(gal)
Efficiency
Rating/Pilot
(Int/Ext)
Recovery Eff
NEEA Heat Pump Type
Condition
DHW Heater 1
Gas
Small
1"
0
0.94 EF
199,000 Btu/hr
R-0
n/a
n/a
Instan a
/n
SPACE CONDITIONING SYSTEMS 1 'Aft 00#* AV*
01 f�
, 02L j i 03
04�
05
06
SC Sys Name (
"Wystem Type Heating Unit Name f
Cooling Vnit Name r•.
Fan Name
Distribution Name
HVAC Split Systeml
Other Heating and'Cooling 9A
System Heating Component 1
V t 1.0-V tf~ If^%
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFurnace
1
95 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Name
System Type
Number of Units
Efficiency
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
I
SplitAirCond
1
1
11.7
1 7
14
Not Zonal
1
Single Speed
1
Cooling Component
1 1-hers-cool
Registration Number: 217-P010290052B-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:41:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 19:41:49
'CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CFI R-PRF-01
Project Name: Codorniz Plan - SF1 Cassia
Calculation Description: Title 24 Analysis
Calculation Date/Time: 19:40, Fri, Dec 15, 2017 Page 12 of 13
Input File Name: RJT Homes - Codorniz SF-1 Cassia - Revised 12-14-17.ribdl6x
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Not Required
Not Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
LowLICod
Sealed and tested
6
Conditioned zone (VLL)
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
See RA3.1.4.3.8
Required
Not Required
Not Required
Not Required
—
HVAC -FAN SYSTEMS ,I ,'"r.,- A H I I (I \� .11
'I`�
01 i ` '
`I ��y xJ�� CIE
,. ! \� ((� W2\� L� 3.k U D
g
1 7 U 03 �0
04
Name /,/
� W .= Type < C' 0 11
\ J'JFa!FPower-(Watts/,CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan w
V v 0.58 y
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
43
0.25
Default
0
Required
Registration Number: 217-P010290052B-000-000-0000000-0000 Registration DateRme: 2017-12-18 09:41:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 19:41:49
0
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name: Codorniz Plan - SF1 Cassia Calculation Date/Time: 19:40, Fri, Dec 15, 2017 Page 13 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-1 Cassia - Revised 12-14-17.ribdl6x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature: ,c44a CJ /ZPC�� �/
p p
Michele J Kler
Company:
Signature Date:
Advancing Home Performance, Inc.
2017-12-16 15:43:42
Address:
CEA/HERS Certification Identification (If applicable):
74998 Country Club Drive.
City/State/Zip:
Phone:
Palm Desert, CA 92260
760-851-8648
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business'and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
- Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plansyand specifications submitted to,the enforcementEagency for appeoval with,this,building permit application.
Responsible Designer Name:
11 L t
pon#sible resigner Sig atU
Chad Meyer (08�1
(Res
yer
i !%/ {`�1,�L
I i !t`i.dclA
Company:
Date Signed: i► �^�a,
1'2-18
RJT Homes
20 7 009:41:4�4"�
Address:
License:
PO Box 810
N/A
City/State/Zip:
Phone:
La Quinta, CA 92253
760-564-6555
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 217-Po10290052B-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:41:44
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-12-15 19:41:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CFI R-PRF-01
Project Name: Codorniz Plan - SF-2 Sage
Calculation Description: Title 24 Analysis
Calculation Date/Time: 20:02, Fri, Dec 15, 2017 Page 1 of 13
Input File Name: RJT Homes - Codorniz SF-2 Sage - Revised 12-14-17.ribd16x
GENERAL INFORMATION
01
Project Name
Codorniz Plan - SF-2 Sage
02
Calculation Description
Title 24 Analysis
03
Project Location
Avenue 52 and Jefferson Street
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.2.1 (695)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.1
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
1504
15
Number of Zones
1
16
Slab Area (ft2)
722
17
Number of Stories
2
18
Addition Cond. Floor Area
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ft)
n/a
21
Glazing Percentage (%)
23.3%
COMPLIANCE RESULTS-
01
Building Complies with Computer Performance A#00 AWAW XM 1 ,
02
.n 'l w w *i u.r. r+ x �-+ w ri. �r..�r-�
This building incorporates features that rtiequire field testing -and/or verification by a certfied HERS rateaunder the super�visi`on of a CEC-approved HERS provider.
03
This building incorporates one or mo` a Special FeattuuresIshow below OW W WL W 4t ' M�
l te'l '+ar . Rwf 4.� '"r"p #. i Ar . R li sf # O -�s 9S
This compliance analysis is'wand�only for'permrt?applrcat�ons through_October 24, 2017
Registration Number: 217-P010265039C-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATEJII�WJBY
la-WW41.0910
Registration Date/Time: 2017-12-18 09:42:19
Report Version - CF1 R-07312017-695
DEC 2 8 2017
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
HERS Provider: CaICERTS Inc.
Report Generated at: 2017-12-15 2030
pmd
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF-2 Sage Calculation Date/Time: 20:02, Fri, Dec 15, 2017 Page 2 of 13
s
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-2 Sage - Revised 12-14-17.ribdl6x
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.12 2.67
-1.55
-138.4%
Space Cooling
99.93 82.75
17.18
17.2%
IAQ Ventilation
1.38 1.38
0.00
0.0%
Water Heating
8.34 7.20
-
1.14
13.7%
PV Credit
-- 0.00
0.00
--
North Facing Compliance Total
110.77 94.00
16.77
15.1%
Space Heating
1.12 2.21
-1.09
-97.3%
Space Cooling
99.93 85.25
14.68
14.7%
IAQ Ventilation
1.38 1.38
0.00
0.0%
Water Heating
8.34 7.20
1.14
13.7%
PV Credit
l/
-- 0.00
0.00
--
East Facing Compliance Total -.
w ._
110.77 96.04
14.73
13.3%
Space Heating
1.12 1.30
-0.18
-16.1%
- Space Cooling
9 3 822..63
��yy
17.30
17.3%
IAQ Ventilation
138 1'.38
0.00
0.0%
Water Heating
8'34_ ______.ER
-
1.14
13.7%
PV Credit
H
- ko I
0.00
--
South Facing Compliance Total
110.77 92.51
18.26
16.5%
Space Heating
1.12 1.93
-0.81
-72.3%
Space Cooling
99.93 93.65
'6.28
6.3%
IAQ Ventilation
1.38 1.38
0.00
0.0%
Water Heating
8.34 7.20
+
1.14
13.7%
PV Credit
-- 0.00
0.00
--
West Facing Compliance Total
110.77 104.16
6.61
6.0%
Registration Number: 217-P010265039C-000-000-0000000-0000 Registration DateRme: 2017-12-18 09:42:19
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-07312017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-12-15 20:03:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF-2 Sage Calculation Date/Time: 20:02, Fri, Dec 15, 2017 Page 3 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-2 Sage - Revised 12-14-17.ribdl6x
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV
Final EDR of Proposed Design
North
54.6
49.1
0.0
49.1
East
54.6
49.8
0.0
49.8
South
54.6
48.6
0.0
48.6
West
54.6 ;
52.4
0.0
52.4
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30%orgreater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement_ for Single Family�in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
a *�-' �"
t `
photovoltaic P renewableener
p ( V) gy generation sufficientiq achieve-a'Flnal Energy Design Rating'(EDR) of zero or less.; The PV System must be verified.
REQUIRED SPECIAL FEATURES /� '"CAI I "_ I A\ I I �i I I I I it
The following are features that must be installed as condition for meetinglthejmodeted energy performance foWhisom.= A
� computer analysis.
• Cool roof - k � r a u .n .rw y r`+rw Y.r r .•►:r w
• Insulation below roof deck
• Window overhangs and/or fins
• Exposed slab floor in conditioned zone ,
• Non-standard duct location (any location other than attic)
• Pipe insulation, all lines 0 '
A ..
Registration Number: 217-P010265039C-000-000-6000000-0000 Registration Date/Time: 2017-12-18 09:42:19
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-12-15 20:03:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF-2 Sage Calculation Date/Time: 20:02, Fri, Dec 15, 2017 Page 4 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-2 Sage - Revised 12-14-17.ribdl6x
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy, performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Verified low -leakage ducts in conditioned space must meet maximum 25 cfm leakage to outside (RA3.1.4.3.8)
Domestic Hot Water System Verifications:
-- None -- 4 A
BUILDING - FEATURES INFORMATION-
01
% 02.,
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
,� Units „
?Number.of�Bedrooms-
..,
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Codorniz Plan - SF-2 Sage
1504' ,If
1 If ff
( ;A-013
1
? 0
1
ZONE INFORMATION I% `� '"�-4"',g $r I!.( 0 vi
01
02 'N-A
rd
64 V (
OS R
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
1st Floor
Conditioned
HVAC Split Systeml
1504
9
DHW Sys 1
i
Registration Number: 217-P010265039C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:42:19 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 20:03:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF-2 Sage Calculation Date/Time: 20:02, Fri, Dec 15, 2017 Page 5 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-2 Sage - Revised 12-14-17.ribdl6x
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door Area (ft2)
Tilt (deg)
Exterior Wall Front N 13x
1st Floor
R-13 Wall w/R-5
0
Front
117
72
90
Exterior Wall Right W - 5
1 st Floor
R-13 Wall w/R-5
270
Right
45
15
90
Exterior Wall Front N - 1
1st Floor
R-13 Wall w/R-5
0
Front
140
45
90
Exterior Wall Left E - 8.
1st Floor
R-13 Wall w/R-5
0
Front
77
15
90
Exterior Wall Front N - 5
1 st Floor
R-13 Wall w/R-5
0
Front
50
24
90
Exterior Wall Left E - 11
1st Floor
R-13 Wall w/R-5
90
Left
99
25
90
Exterior Wall Rear S 7.8x
1 st Floor
R-13 Wall w/R-5
0
Front
62.6
0
90
Exterior Wall Rear S - 5.
1st Floor
R-13 Wall w/R-5
180
Back
41.6
12.5
90
Exterior Wall Right W - 2
/ 1 st Floor
R-13 Wall w/R-5
270
Right
243
32.9988
90
Exterior Wall Front N 13.
1st Floor
R-13 Wall w/R-5
0
Front
119
23.9976
90
Exterior Wall Left E 10.7 ..
1st Floor
R-13 Wall w/R-5
90
Left
86
0
90
Exterior Wall Front N 15.
1 st Floor _
R-13 Wall w/R-5
_ 0
_ Front
76
15
90
Exterior Wall Right W 1.5
1st Floor €
R-13�Wa I /R-51_
U—
Front
14
0
90
Exterior Wall Front N 5.5
f 1st Flo r
R;13 WaIL R-
r 9)^
f [Front
50
18.1038
90
Exterior Wall Left E 18x9
r 1st Floes
R-13 allow/R-5
9
Left
162
12.5
90
Exterior Wall Rear S 6.5x
1st Floor
41R-t3 Wall w/R-5
—00 180
Baca
; 59
15
90
Exterior Wall Left E 8x9
1st Floor
R-13 Wall w/R-5
90
Left
72
0
90
Exterior Wall Rear S 7.75
1st Floor
R-13 Wall w/R-5
0
Front
69.75
0
90
Exterior Wall Rear S 6.75
1 st Floor
R-13 Wall w/R-5
180
Back
60.75
8
90
Exterior Wall Right W 8x9
1st Floor
R-13 Wall w/R-5
180
Back
72
0
90
Exterior Wall Rear S 13x9
1 st Floor
R-13 Wall w/R-5
180
Back 1117
15
90
Exterior Wall Right W 27x
1st Floor
R-13 Wall w/R-5
270
Right
243
25.2
90
Interior Surface to Garag
1 st Floor>>Garage_
R-13 Wall
342
17.3
1st Floor Roof
1st Floor
R-22 Roof Attic Codorniz
44
2nd Floor Roof
1st Floor
R-22 Roof Attic Codorniz
782
Exterior Wall Left 19.5x9
Garage_
Garage Exterior Wall
90
Left
176
10
90
Exterior Wall Front 21x9
Garage_
Garage Exterior Wall
180
Back
189
128
90
Exterior Wall Right 8x9
Garage_
Garage Exterior Wall
270
Right
72
0
90
Garage Roof
Garage_
R-0 Roof Attic
462
Registration Number: 217-P010265039C-000-000-0000000-0000 Registration Dateffime: 2017-12-18 09:42:19 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-07312017-695 Report Generated at: 2017-12-15 20:03:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF-2 Sage Calculation Date/Time: 20:02, Fri, Dec 15, 2017 Page 6 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-2 Sage - Revised 12-14-17.ribdl6x
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Garage_
Attic Garage Roof Cons
Ventilated
4
0.1
0.85
No
No
Attic 1st Floor
Attic Rooflst Floor
Unventilated
4
0.63
0.85
No
Yes
. i,✓
Registration Number: 217-P010265039C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:42:19 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 - Report Generated at: 2017-12-15 20:03:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF-2 Sage Calculation Date/Time: 20:02, Fri, Dec 15, 2017 Page 7 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-2 Sage - Revised 12-14-17.ribdl6x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft)
LI-factor
SHGC
Exterior Shading
Window 9080 SLDR - Fen 5
Window
Exterior Wall Front N 13x (Front-0)
9.0
8.0
1
72.0
0.30
0.20
Insect Screen (default)
Window 2660SH - Fen 6
Wndow
Exterior Wall Right W - 5 (Right-270)
2.5
6.0
1
1 15.0
0.30
0.20
1 Insect Screen (default)
Window 2660SH - Fen 7
Window
Exterior Wall Front N - 1 (Front-0)
2.5
6.0
1
15.0
0.30
0.20
Insect Screen (default)
Window 2660SH - Fen 8
Window
Exterior Wall Front N - 1 (Front-0)
2.5
6.0
1
15.0
0.30
0.20
Insect Screen (default)
Wndow 2660SH - Fen 9
Window
Exterior Wall Front N - 1 (Front-0)
2.5
6.0
1
15.0
0.30
0.20
Insect Screen (default)
Window 2660SH - Fen 10
Window
Exterior Wall Left E - 8. (Front-0)
2.5
6.0
1
15.0
0.30
0.20
Insect Screen (default)
Window 2660SH - Fen 11
Window
Exterior Wall Left E - 11 (Left-90)
2.5
6.0
1
15.0
0.30
0.20
Insect Screen (default)
Window 2640SH - Fen 12
Window
Exterior Wall Left E - 11 (Left-90)
2.5
4.0
1
10.0
0.30
0.20
Insect Screen (default)
Window 2650SH - Fen 13
Window
Exterior Wall Rear S - 5. (Back-180)
2.5
5.0
1
12.5
0.30
0.20
Insect Screen (default)
Window 8 GB - Fen 1
Wndow
Exterior Wall Right W - 2 (Right-270)
2.0
.7
1.071
1.5
0.64
0.66
Insect Screen (default)
Window 8 GB - Fen 2
Window
Exterior Wall Right W - 2 (Right-270)
2.0
.7
1.071
1.5
0.64
0.66
Insect Screen (default)
Window 2660SH - Fen 3A
Window
Exterioa-1Na11--Right W 12 (Right-270 f
;:�N2 5 d
�6.0
n �2
30.0
0.30
0.20
Insect Screen (default)
Door 3068FR -Fen 18
Wiridow "_
Exterior Wall FrontN 1P(Front-0)
r""3A
'� 6.6
1.2 2
�24.0
0.30
0.20
Insect Screen (default)
Window 2620FG - Fen 19
Window
Exterior Wall FrontjN-45�(Front-0 1
I U2.54 C
`-2:67
L( U1 U '
�500
0.28
0.22
Insect Screen (default)
Window 2620FG - Fen 20
Window
-* Exterior Wall Front N�15. (Font-0) '
R2.5Z>
2.01
1
R 5.0
0.28
0.22
Insect Screen (default)
Window 2620FG- Fen 21
Window
Exterior Wall Front N 15. (Front-0)
2.5
2.0
1
5.0
0.28
0.22
Insect Screen (default)
Door 2868FR - Fen 22
Window
Exterior Wall Front N 5.5 (Front-0)
2.6
6.6
1.055
18.1
0.30
0.20
Insect Screen (default)
Window 2650SH - Fen 23
Window
Exterior Wall Left E 18x9 (Left-90)
2.5
5.0
1
12.5
0.30
0.20
Insect Screen (default)
Wndow 3050SH - Fen 24
Window
Exterior Wall Rear S 6.5x (Back-180)
3.0
5.0
1
15.0
0.30
0.20
Insect Screen (default)
Window 2040SH- Fen 25
Window
Exterior Wall Rear S 6.75 (Back-180)
2.0
4.0
1
8.0
0.30
0.20
Insect Screen (default)
Window 3050SH - Fen 26
Window
Exterior Wall Rear S 13x9 (Back-180)
3.0
5.0
1
15.0
0.30
0.20
Insect Screen (default)
Window 2626FG - Fen 14
Window
Exterior Wall Right W 27x (Right-270)
2.5
2.5
1.008
6.3
0.28
0.22
Insect Screen (default)
Window 2626FG - Fen 15
Window
Exterior Wall Right W 27x (Right-270)
2.5
2.5
1.008
6.3
0.28
0.22
Insect Screen (default)
Window 2626FG - Fen 16
Window
Exterior Wall Right W 27x (Right-270)
2.5
2.5
1.008
6.3 1
0.28 1
0.22 1
Insect Screen (default)
Wndow 2626FG - Fen 17
Window
Exterior Wall Right W 27x (Right-270)
2.5
2.5
1.008
6.3
0.28
0.22
Insect Screen (default)
Window 2640SH - Fen 27
Window
-Exterior Wail Left 19.5x9 (Left-90)
2.5
4.0
1
10.0
0.30
0.20
Insect Screen (default)
Registration Number: 217-P010265039C-000-000-0000000-0000 Registration Dateffime: 2017-12-18 09:42:19 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 20:03:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF-2 Sage Calculation Date/Time: 20:02, Fri, Dec 15, 2017 Page 8 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-2 Sage - Revised 12-14-17.ribdl6x
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door 3080
Exterior Wall Front N - 5
24.0
0.34
Door 2868
Interior Surface to Garag
17.3
0.34
Garage Door 16080 OHD
Exterior Wall Front 21x9
128.0
0.70
'PVI�
Registration Number: 217-P010265039C-000-000-0000000-0000 Registration Dateffime: 2017-12-18 09:42:19
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
t
HERS Provider: CaICERTS inc.
Report Generated at: 2017-12-15 20:03:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1R-PRF-01
Project Name: Codorniz Plan - SF-2 Sage
Calculation Description: Title 24 Analysis
Calculation Date/Time: 20:02, Fri, Dec 15, 2017 Page 9 of 13
Input File Name: RJT Homes - Codorniz SF-2 Sage - Revised 12-14-17.ribd16x
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
Window 9080 SLDR - Fen 5
1.5
8.1
2
2
0
15
0
4
0
0
0
0
0
Window 2660SH - Fen 6
1.5
8.1
2
2
0
0
0
0
0
13
0
1.25
0
Window 2660SH - Fen 7
1.5
1
2
2
0
0
0
0
0
0
0
1 0
0
Window 2660SH - Fen 8
1.5
1
2
2
0
0
0
0
0
0
0
0
0
Window 2660SH - Fen 9
1.5
1
2
2
0
0
0
0
0
0
0
0
0
Window 2660SH - Fen 10
1.5
1
2
2
0
7.5
0
4.75
0
0
0
0
0
Window 2660SH - Fen 11
1.5 i
8.1
2
2
0
0
0
0
0
2
0
0.1
0
Window 2640SH - Fen 12
1.5
8.1
2
2
0
0
0
0
0
2
0
6
0
VUndow 2650SH - Fen 13
1.5
8.1
2
2
0
0
0
0
0
8
0
7
0
Window 8 GB - Fen 1
1.5
8.1
2
2
0
0
0
0
0
0
0
0
0
Window 8 GB - Fen 2
1.5
8.1
�2
n 2'^A
,i r.,7r1) -7::�N
=; 0'=
on
0
0
0
0
0
0
VVindow 2660SH - Fen 3,4
7 1.5! ,
8.1
2
' 2
! 4 - 0y ,�
t 0 1-�
01 t. I'
N q?rd
0
0
0
0
0
Door 3068FR -Fen 18
r1.5 '.
\1
2`
U '2 s!
0 11:
0
0U
U 0
0
0
0 1
0
0
Window 2620FG - Fen 19
1.5
H2 F
R 2 4;
R
-10:6 NJ
I OJ-3
F 9.R
0
10.6
0
3.2
0
Window 2620FG - Fen 20
1.5
1
2
2
0
10.6
0
9.5
0
10.6
0
6.5
0
Window 2620FG- Fen 21
1.5
1
2
2
0
10.6
0
3.5
0
10.6
0
9.2
0
Door 2868FR - Fen 22
1.5
1
2
2
0
0
0
0
0
0
0
0
0
Window 2650SH - Fen 23
1.5
1
2
2
0
0
0
0
0
0
0
0
0
Window 3050SH - Fen 24
1.5
1
2
2
0
8
0
3.91
0
0
0
0
0
Window 2040SH- Fen 25
1.5
1
2
2
0
0
0
0
0
0
0
0
0
Window 3050SH - Fen 26
1.5
1
2
2
0
0
0
0
0
8
0
6.75
0
Window 2626FG - Fen 14
1.5
1
2
2
0
0
0
0
0
0
0
0
0
Window 2626FG - Fen 15
1.5
1
2
2
0
0
0
0
0
0
0
0
0
Window 2626FG - Fen 16
1.5
1
2
2
0
0
0
0
0
0
0
0
0
Window 2626FG - Fen 17
1.5
1
2
2
0
0
0
0
0
0
0
0
0
Registration Number: 217-P010265039C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:42:19 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 20:03:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF-2 Sage Calculation Date/Time: 20:02, Fri, Dec 15, 2017 Page 10 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-2 Sage - Revised 12-14-17.ribdl6x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
• Inside Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x4
Garage Exterior Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.361
Exterior Finish: 3 Coat Stucco
Ceilings (below
Inside Finish: Gypsum Board
R-0 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
none
0.481
Cavity/Frame: no insul. /2x4
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Garage Roof Cons
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity / Frame: R-9 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofist Floor
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 9
0.103
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Cavity/Frame: R-13/2x4
µ
Sheathing/Insulation: R5 Sheathing
R-13 Wall w/R-5
Exterior -Walls
Wood Fram_ed_Wall
t.y 2x4f@ 16 in. O.0
R 13„
0.063
Exterior Finish: 3 Coat Stucco
Ceilings. (below,
r '
A
DCavity/Frame:
Inside Finish: Gypsum Board
R-9.1 /2x4
R-22 Roof Attic Codorniz
attic) j ` "
> Wood Framed•Ceihng •
2x4 @<16 m, O.C. G
�R 22
07Q
Over Ceiling Joists: R 12.9 insul.
C,r
H
�r i� 0
y/
� I �
� R
Inside Finish: Gypsum Board
of
i
€ .a
x
4
Cavity/Frame: R-13/2x4
R-13 Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.092
• Other Side Finish: Gypsum Board
SLAB FLOORS
01
02
03
04
05
06
07
Name
zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab -on -Grade
1st Floor
248
0.1
None
1
No
Slab -on -Grade 2
1st Floor
474
0.1
None
0
No
Slab -on -Grade 3
Garage_
462
0.1
None
0
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
---
Registration Number: 217-P010265039C-0oo-000-0000000-0000 Registration DateMme: 2017-12-18 09:42:19 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 20:03:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: Codorniz Plan - SF-2 Sage
Calculation Description: Title 24 Analysis
Calculation Date/Time: 20:02, Fri, Dec 15, 2017 Page 11 of 13
Input File Name: RJT Homes - Codorniz SF-2 Sage - Revised 12-14-17.ribdl6x
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1 (1)
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
Tank
Energy
Tank Insulation
Tank Location or
Heater
Number
Volume
Factor or
Input
R-value
Standby Loss /
Ambient
Name
Element Type
Tank Type
of Units
(gal)
Efficiency
Rating/Pilot
(Int/Ext)
Recovery Eff
NEEA Heat Pump Type
Condition
DHW Heater 1
Gas
Instan anll
1
0
0.94 EF
199,000 Btu/hr
R-0
n/a
/n
n/a
SPACE CONDITIONING SYSTEMS
01 /'
, ' 02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC Split Systeml �`
Other Heating and Cooling
�". Systems
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC-HEATING UNIT TYPES
01 ;�
�'°` �i. +i U '02----.-!' 1r U 4 CZ/ flrr/ L
LE 0 035:�O V
04
Name L'" �`
f K System Type K tj V I t
) Numbetof Units
Efficiency
Heating Component 1
CntrlFurnace
1
92 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Name
System Type
Number of Units
Efficiency
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
1
12.5
15
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Registration Number: 217-P010265039C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:42:19 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 20:03:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R-PRF-01
Project Name: Codorniz Plan - SF-2 Sage Calculation Date/Time: 20:02, Fri, Dec 15, 2017 Page 12 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-2 Sage - Revised 12-14-17.ribdl6x
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
LowLICod
Sealed and tested
6
Conditioned zone (VLL)
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
See RA3.1.4.3.8
Required
Not Required
Not Required
Not Required
--
HVAC-FAN SYSTEMS h
01
p 02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
- Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION `" — 1 Allow 000 JF"I __
01
Jlk Jr" 02 J Jr'#Jr
03
Name
! iM '040 *Verified Fan Watt Dr� A* A Ik ` 40 (�
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan "IlkH
t ,'5 Requiretl
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
45
0.25
Default
0
Required
Registration Number: 217-P010265039C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:42:19 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 20:03:34
` •CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01
Project Name: Codorniz Plan - SF-2 Sage Calculation Date/Time: 20:02, Fri, Dec 15, 2017 Page 13 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-2 Sage - Revised 12-14-17.ribd16x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature: �p �]
C l2 &0Q CJ&
Michele J Kier
Company:
Signature Date:
Advancing Home Performance, Inc.
2017-12-16 15:41:38
Address:
CEA/HERS Certification Identification (If applicable):
74998 Country Club Drive.
City/State/Zip:
Phone:
Palm Desert, CA 92260
760-851-8648
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations. "�--w_ ! r \� _,.-,-,,,—
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to.the enforcement,aggncy for approval v,/ith,thi�s-building permit application.
Zvi
Responsible Designer Name:
ka �r �t
Responsible Designer Signatufe��
Chad Meyer
yer
Company: �,f
RJT Homes l� H R S
Date Signed: 0
1`2 2:1
20 7 18 9.
Address:
License:
PO Box.810
Codorniz
City/State/Zip:
Phone: '
La Quinta, CA 92253
760-564-6555
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 217-P010265039C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:42:19
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-12-15 20:03:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorriiz Plan - SF3 Cordia Calculation Date/Time: 19:32, Fri, Dec 15, 2017 Page 1 of 11
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-3 A & B - revised 12-14-17.ribd16x
GENERAL INFORMATION
01
Project Name
Codorniz Plan - SF3 Cordia
02
Calculation Description
Title 24 Analysis
03
Project Location
Avenue 52 and Jefferson Street
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.2.1 (695)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.1
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
3462
15
Number of Zones
1
16
Slab Area (ft2)
950
17
Number of Stories
2
18
Addition Cond. Floor Area
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ft)
n/a
21
Glazing Percentage (°/.)
9.4%
COMPLIANCE RESULTS �� r--: -
01
Building Complies with Computer Performance
02
.v t r •,--�' x v t. � �+, � �, hr mot... as x �f..ss''---.
This building incorporates features~that rtiequire field testing.and/or�venfication 6y a certified HERS rate} Funder the supernsjon of a CEC-approved HERS provider.
03
This building incorporates one. or more Special Featu a shown below ' '�� � .,i
This compliance analysis istvalid only for permrt�apphcations thcoughKOctober 24, 2017
CITY Olt LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE 1 ��tw��
SuA'61-1 • so 14
Registration Number: 217-Po10265023C-000-000-0000000-0000 Registration DateTme: 2017-12-1809:41:04
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
DEC 2 8 2017-
CITY OF LA 004TA
COMMUNITY DEVELOPMENT
HERS Provider: CaICERTS inc.
Report Generated at: 2017-12-15 19: :5"
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R-PRF-01
Project Name: Codorniz Plan - SF3 Cordia Calculation Date/Time: 19:32, Fri, Dec 15, 2017 Page 2 of 11
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-3 A & B - revised 12-14-17.ribdl6x
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
0.68 1.27
-0.59
-86.8%
Space Cooling
51.82 36.76
15.06
29.1%
IAQ Ventilation
0.86 0.86
0.00
0.0%
Water Heating
3.80 3.26
0.54
14.2%
PV Credit
-- 0.00
0.00
--
North Facing Compliance Total
57.16 42.15
15.01
26.3%
Space Heating
0.68 1.04
-0.36
-52.9%
Space Cooling
51.82 35.67
16.15
31.2%
IAQ Ventilation
0.86 0.86
0.00
0.0%
Water Heating
3.80 3.26
0.54
14.2%
PV Credit
-- 0.00
0.00
---_
East Facing Compliance Total f
57.16 40.83
16.33
28.6%
Space Heating
'""� 0.68 0.77
-0.09
-13.2%
Space7
Cooling 51 82 c-
15.05
29.0%
IAQ Ventilation
0:86 0.86
R
0.00
0.0%
Water Heating:80-
_
___ _
0.54
14.2%
PV Credit
- , S kc0 I
i
0.00
--
South Facing Compliance Total
57.16 41.66
15.50
27.1%
Space Heating
0.68 0.99
-0.31
-45.6%
Space Cooling
51.82 38.74
13.08
25.2%
IAQ Ventilation
0.86 0.86
0.00
0.0%
Water Heating
3.80 3.26
0.54
14.2%
PV Credit
-- 0.00
0.00
--
West Facing Compliance Total
57.16 43.85
13.31
23.3%
Registration Number: 217-Po10265023C-000-000-0000000-0000 Registration DateRme: 2017-12-18 09:41:04 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 19:32:59
• y
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01
Project Name: Codorniz Plan - SF3 Cordia Calculation Date/Time: 19:32, Fri, Dec 15, 2017 Page 3 of 11
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-3 A & B - revised 12-14-17.ribd16x
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to••zero out" its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV
Final EDR of Proposed Design
North
49.4
40.6
0.0
40.6
East
49.4
39.9
0.0
39.9
South
49.4 A
40.3
0.0
40.3
West
49.4
41.6
0.0
41.6
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirementof 30%0 ocgreater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for�Singlle�Family.in climate �zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
photovoltaic (PV) renewable energy generation sufficient�to�achieve•a Final Energy D• esign`Rating'(EDR) of zero.or less. The PV System must be verified.
REQUIRED SPECIAL FEATURES ���� ��Qt II A". I" II A I �} Ire H 11 W"- 6
The following are features that must be installed as condition for meetingithe7modeled energy performanccewfo this computer analysis.
^Y Cool roof `� .r.I' -i'r Y' •! `VF' W Y. -YY!• f9Vi i{ 1LL
•
• Insulation below roof deck
• Window overhangs and/or fins
• Exposed slab floor in conditioned zone
• Non-standard duct location (any location other than attic)
• Pipe insulation, all lines
Registration Number: 217-P010265023C-000-000-0000000.0000 Registration Date/Time: 2017-12-18 09:41:04
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-12-15 19:32:59
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF3 Cordia Calculation Date/Time: 19:32, Fri, Dec 15, 2017 Page 4-of 11
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-3 A & B - revised 12-14-17.ribdl6x
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Verified low -leakage ducts in conditioned space must meet maximum 25 cfm leakage to outside (RA3.1.4.3.8)
Domestic Hot Water System Verifications:
• -- None --
BUILDING - FEATURES INFORMATION i 0
01
03
04
05
06
•07
Project Name
Conditioned Floor Area'(ft2)'
-Number of Dwelling
' Units
Numberof Bedrooms.
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Codorniz Plan - SF3 Cordia
3462
` 1 II i r
1L --af,,j II 1:
, I f l le—_
! 0
1
ZONE INFORMATION I 'z"', N�,S� 141 L�� "- u V 17 1u u U Q
01
02 "-A
H r3 S P
f4 V f
oy- R
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Main House
Conditioned
HVAC Split Systeml
3462
9
DHW Sys 1
«
Registration Number: 217-Po10265023C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:41:04
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-12-15 19:32:59
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF3 Cordia Calculation Date/Time: 19:32, Fri, Dec 15, 2017 Page 5 of 11
Calculation Description: Title 24 Analysis Input File Name: RJT Homes -'Codorniz SF-3 A & B - revised 12-14-17.ribal6x
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft)
Tilt (deg)
Exterior Wall Front N 1Ox
Main House
R-13 Wall (Codorniz)
0
Front
110
75
90
Exterior Wall Right W - 5
Main House
R-13 Wall (Codorniz)
270
Right
45
0
90
Exterior Wall Front N - 4
Main House
R-13 Wall (Codorniz)
0
Front
41
24
90
Exterior Wall Right W - 5 2
Main House
R-13 Wall (Codorniz)
270
Right
53
15
90
Exterior Wall Front N - 1
Main House
R-13 Wall (Codorniz)
0
Front
122
38
90
Exterior Wall Left E - 13
Main House
R-13 Wall (Codorniz)
90
Left
122
0
90
Exterior Wall Rear S - 5.
Main House
R-13 Wall (Codorniz)
180
Back
50
0
90
Exterior Wall Right W - 2
Main House
R-13 Wall (Codorniz)
270
Right
23
0
90
Exterior Wall Rear S - 4.
Main House
R-13 Wall (Codorniz)
180
Back
41
0
90
Exterior Wall Left E - 2.
Main House
R-13 Wall (Codorniz)
90
Left
23
0
90
Exterior Wall Rear S - 7x
Main House
R-13 Wall (Codorniz)
180
Back
63
0
90
Exterior Wall Right W - 1
. \ Main House _
JR-13 Wall (Codorniz)
270
_ Right
131
18
90
Exterior Wall Right W - 1 2
Main House � � a
l k- Wall (Codorniz ))
�70
tRight
160
40
90
Exterior Wall Front N 13x
%Main, House j
[hV3 Wall (Codorniz) N
_ 0
Frontt
104
18.1053
90
Exterior Wall Left E 1.5x
% .' Main Ho'�use
R-13 Wall Codorniz) ,.
( f�.a !I^-
90
TMR M R.
Left
'A'4.. •r.=-' M�
14
.
0
90
Exterior Wall Front N 10.
Main Ho use
1 13 All (Codorniz)
Id0
L-0 Front r
95
8
90
Exterior Wall Left E 34.7
Main House
R-13 Wall (Codorniz)
90
Left
313
63
90
Exterior Wall Rear S 14x9
Main House
R-13 Wall (Codorniz)
180
Back
126
12.6
90
Exterior Wall Right W 1.7
Main House
R-13 Wall (Codorniz)
270
Right
16
0
90
Exterior Wall Rear S 9.5x
Main House
R-13 Wall (Codorniz)
180
Back
86
12.6
90
Exterior Wall Right W 34.
Main House
R-13 Wall (Codorniz)
270
Right
155
25
90
Interior Surface to Garag
Main House>>Garage_
R-13 Wall
342
17.8
1st Floor Roof
Main House
R-22 Roof Attic Codorniz
208
2nd Floor Roof
Main House
R-22 Roof Attic Codorniz
742
Exterior Wall Left 30.29x
Garage_
Garage Exterior Wall
90
Left
272.6
79
90
Exterior Wall Rear 32.7x9
Garage_
Garage Exterior Wall
180
Back
294.4
72
90
Exterior Wall Right 11.04
Garage_
Garage Exterior Wall
27
- specify - 1
99.4
15
90
Garage Roof
Garage_
R-0 Roof Attic
447
Registration Number: 217-PO10265023C-000-000-0000000.0000 Registration DateRme: 2017-12-18 09:41:04 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 19:32:59
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF3 Cordia Calculation Date/Time: 19:32, Fri, Dec 15, 2017 Page 6 of 11
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-3 A & B - revised 12-14-17.ribd16x
ATTIC
d1
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic _Garage_
Attic Garage Roof Cons
Ventilated
4
0.1
0.85
No
No
Attic Main House
Attic RoofMain House
Unventilated
4
0.63
0.85
No
Yes
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
Window 7680 SLDR - Fen 7
Window
Exterior Wall Front N 10x (Front-0)
7.5
8.0
1
60.0
0.29
0.23
Insect Screen (default)
Window 7620 FG - Fen 6
Window
Exterior Wall Front N 10x (Front-0)
7.5
2.0
1
15.0
0.28
0.22
Insect Screen (default)
Window 2660SH - Fen 8
Window
Exterior Wall Right W - 5 2 (Right-270)
2.5
6.0
1
15.0
0.30
0.20
Insect Screen (default)
Window 2660SH - Fen 9.10
Window
Exterior Wall Front N - 1 (Front-0)
2.5
6.0
2
30.0
0.30
0.20
Insect Screen (default)
Window 2040 SH - Fen 11
Window
Exterior Wall Front N - 1 (Front-0)
2.0
4.0
1
8.0
0.30
0.20
Insect Screen (default)
Window 3060 SH -Fen 1
Window
Exterior'W Wi ht W 0 (Rf ht 2" �
9.. a.i , . 9
3.0 4
r6.0
1 1 .4
.18.0
0.30
0.20
Insect Screen (default)
Window 2660 SH -Fen 2
Window �'.`
t�Exterior+Wall Right W C1 2 (Right-270 1
? 2.5
6.0
f 15.0
0.30
0.20
Insect Screen (default)
Window 2620FG - Fen 3
Window 'I
�k&erior W 1111=Rig V11 11 2 (Right-270 1
%2.5* t
VW2 0
0 101 4 '
IW59
0.28
0.22
Insect Screen (default)
Window 2660SH -Fen 4
Window
Exterior WaII Righ'fW -1=2 (Right-270)'1'
2.5
6.0
1'15.0
0.30
0.20
Insect Screen (default)
Window 2620FG - Fen 5
Window
Exterior Wall Right W - 1 2 (Right-270)
2.5
2.0
1
5.0
0.28
0.22
Insect Screen (default)
Door 2868FR - Fen 14
Window
Exterior Wall Front N 13x (Front-0)
2.7
6.7
1.022
18.1
0.28
0.22
Insect Screen (default)
Window 2040SH - Fen 15
Window
Exterior Wall Front N 10. (Front-0)
2.0
4.0
1
8.0
0.30
0.20
Insect Screen (default)
Window 2040SH - Fen 16
Window
Exterior Wall Left E 34.7 (Left-90)
2.0
4.0
1
8.0
0.30
0.20
Insect Screen (default)
Window 2650SH - Fen 17,18
Window
Exterior Wall Left E 34.7 (Left-90)
2.5
5.0
2
25.0
0.30
0.20
Insect Screen (default)
Window 3050SH - Fen 19,20
Window
Exterior Wall Left E 34.7 (Left-90)
3.0
5.0
2
30.0
0.30
0.20
Insect Screen (default)
Window 2626FG - Fen 21
Window
Exterior Wall Rear S 14x9 (Back-180)
2.5
2.5
1.008
6.3
0.28
0.22 1
Insect Screen (default)
Window 2626FG - Fen 22
Window
Exterior Wall Rear S 14x9 (Back-180)
2.5
2.5
1.008
6.3
0.28
0.22
Insect Screen (default)
Window 2626FG - Fen 23
Window
Exterior Wall Rear S 9.5x (Back-180)
2.5
2.5
1.008
6.3
0.28
0.22
Insect Screen (default)
Window 2626FG- Fen 24
Window
Exterior Wall Rear S 9.5x (Back-180)
2.5
2.5
1.008
6.3
0.28
0.22
Insect Screen (default)
Window 2650SH- Fen 12,13
Window
Exterior Wall Right W 34. (Right-270)
2.5
5.0
2
25.0
0.30
0.20
Insect Screen (default)
Window 2660SH - Fen 25
Window
Exterior Wall Left 30.29x (Left-90)
2.5
6.0
1
15.0 1
0.30 1
0.20 1
Insect Screen (default)
Window 2660SH - Fen 26
Window
Exterior Wall Right 11.04 (- specify -27)
2.5
6.0
1
15.0
0.30 1
0.20 1
Insect Screen (default)
Registration Number: 217-P01o265023C-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Date/Time: 2017-12-18 09:41:04
Report Version - CF1 R-07312017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-12-15 19:32:59
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF3 Cordia Calculation Date/Time: 19:32, Fri, Dec 15, 2017 Page 7 of 11
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-3 A & B - revised 12-14-17.ribd16x
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door 3080
Exterior Wall Front N - 4
24.0
0.50
Door 2868
Interior Surface to Garag
17.8
0.50
Garage Door 8080 OHD
Exterior Wall Left 30.29x
64.0
0.70
Garage Door 9080 OHD
Exterior Wall Rear 32.7x9
72.0
0.70
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
i'
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
Window 7680 SLDR - Fen 7
1.5
2
2
2
0
5
0
1.25
0
0
0
0
0
Window 7620 FG - Fen 6-
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 2660SH - Fen 8
1.5
0.1
2
2 1.
0
--�- , -
4.5
�_...r�
0 -,
0.91
0
0
0
0
0
Window 2660SH -Fen 9.10
? 1.5 �:
8.1
r 2�
0
0
O j
71� 0
0
0
0
0
0
Window 2040 SH - Fen 11
Window 3060 SH -Fen 1
f 1.5.-r„�
:-1.5
41t8.1
0 1
2
�2 �,-
f E`.,..
�2 A
0"
f, 0_1
*ra
� Of f
R 0�~
0� �
W- OW-%
A 0
0
1.5
0
0
0
3.25
0
0
0
Window 2660 SH - Fen 2
1.5
0O.1
if �2
"2 "�
10
*�" '1l''
K 0�'�`
� O t
0
0
0
0
0
Window 2620FG - Fen 3
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 2660SH - Fen 4
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 2620FG - Fen 5
1.5
0.1
2
2
0
0
0
. 0
0
0
0
0
0
Door 2868FR - Fen 14
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 2040SH - Fen 15
1.5
0.1
2
2
0
0
0
0
0
1.5
0
5.5
0
Window 2040SH - Fen 16
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 2650SH - Fen 17,18
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 3050SH - Fen 19,20
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 2626FG - Fen 21
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 2626FG - Fen 22
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 2626FG - Fen 23
1.5
0.1
2
2
0
0
0
0 1
0
1.75
0
0.33
0
Window 2626FG- Fen 24
1.5
0.1
2 1
2
0
0 1
0
0
0 1
1.75
0
3.75
0
Window 2650SH- Fen 12,13
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Registration Number: 217.Po10265023C-000-000-0000000-0000 Registration Dateffime: 2017-12-18 09:41:04 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 19:32:59
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF3 Cordia Calculation Date/Time: 19:32, Fri, Dec 15, 2017 Page 8 of 11
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-3 A & B - revised 12-14-17.ribdl6x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
• Inside Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4
Garage Exterior Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.361
Exterior Finish: 3 Coat Stucco
Ceilings (below
Inside Finish: Gypsum Board
R-0 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
none
0.481
Cavity/Frame: no insul. /2x4
• Floor Surface: Carpeted
• Floor Deck: Wood Siding/sheathing/decking
• Cavity/Frame: R-19/2x6
R-19 Floor No Crawlspace
Interior Floors
Wood Framed Floor
2x6 @ 16 in. O.C.
R 19
0.048
Ceiling Below Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4 Top Chrd
,J
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Garage Roof Cons
Attic Roofs ; j
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
�
• Cavity / Frame: R-9 / 2x4 Top Chrd
�-
-- y .
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofMain House
Attic Roofs
Wood Framed Ceiling
in. O.0
R 9.
0.103
Roofing: Light Roof (Asphalt Shingle)
I!
104'Wood
°'
C
t
C 1: K 1,R-13
co
• Inside Finish: Gypsum Board
Cavity /Emma: Rion: 13 / R5
Sheathing /Insulation: R5 Sheathing
Wall (Codorniz)
Exteri6f Walls
Framed,Wall
% 7'•••r'�M,"'A
2x4 @ 16 in. O.C.
R 13 -S
0 063
�"' !F vi
Exterior Finish: 3 Coat Stucco
V A -.0 t 11 �
V A"O` t
" t(A
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-22 Roof Attic Codorniz
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 22
0.043
Over Ceiling Joists: R-12.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-13 / 2x4
R-13 Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.092
Other Side Finish: Gypsum Board
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab -on -Grade
Main House
348
0.1
None
1
No
Slab -on -Grade 2
Main House
602
0.1
None
0
No
Slab -on -Grade 3
Garage_
447
0.1
None
0
No
Registration Number: 217-Po10265023C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:41:04 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 19:32:59
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name: Codorniz Plan - SF3 Cordia Calculation Date/Time: 19:32, Fri, Dec 15, 2017 Page 9 of 11
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-3 A & B - revised 12-14-17.ribdl6x
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
—
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1 (1)
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
i1!
Tank
Energy
Tank Insulation
Tank Location or
Heater
Number
Volume
Factor or
Input
R-value
Standby Loss /
Ambient
Name
Element Type
Tank Type
of Units
(gal)
Efficiency
Rating/Pilot
(Int/Ext)
Recovery Eff
NEEA Heat Pump Type
Condition
DHW Heater 1
Gas ��
Instan a Small
1
0
0.94 EF
199,000 Btu/hr
R-0
n/a
/n
n/a
SPACE CONDITIONING SYSTEMS I C- AO**
01
n��—
!
�+ a4 04_
w 05
06
SC Sys Name !`
��ystem Type �,~
„% Heating Unit Name
Cooling Unit Name
w Fan Name
Distribution Name
HVAC Split Systeml
Other Heating and Cooling
System
` "`0 9 A `�"
Heating Component 1
`1l' 0 tE--010 K` t
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFurnace
1
92 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Efficiency
Name
System Type
Number of Units
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
1
12.5
15
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Registration Number: 217-P010265023C-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Date/Time: 2017-12-18 09:41:04
Report Version - CF1 R-07312017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-12-15 19:32:59
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CFI R-PRF-01
Project Name: Codorniz Plan - SF3 Cordia
Calculation Description: Title 24 Analysis
Calculation Date/Time: 19:32, Fri, Dec 15, 2017 Page 10 of 11
Input File Name: RJT Homes - Codorniz SF-3 A & B - revised 12-14-17.ribdl6x
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
LowLlCod
Sealed and tested
6
Conditioned zone (VLL)
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
- - Verification _ _ _ _
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
See RA3.1.4.3.8
Required
Not Required
Not Required
Not Required
---
HVAC -FAN SYSTEMS J �i/ J! �3-1 1( I 1..+"�
01 �� /<
}11
qI
i
r o i L 2 1l__"' .Lf
r� g
� 7 U H U$ 0
04
Name %,r
W = Type < J: X> I —It
\/' JFap Power2(Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan _
V Y s 0.58 L
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
65
0.25
Default
0
Required
Registration Number: 217-P010265023C-000-000-0000000-0000 Registration Date/Time: 20W-12-18 09:41:04 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 19:32:59
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - SF3 Cordia Calculation Date/Time: 19:32, Fri, Dec 15, 2017 • Page 11 of 11
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz SF-3 A & B - revised 12-14-17.ribd16x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature: ��p�/
Michele J Kler
Company:
Signature Date:
Advancing Home Performance, Inc.
2017-12-16 15:45:32
Address:
CEA/HERS Certification Identification (If applicable):
74998 Country Club Drive.
City/State/Zip:
Phone:
Palm Desert, CA 92260
760-851-8648
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations. ` - --.0 ' \
3. The building design features'or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications subinitted to.the enforcement,agency for a pproval.with,this_building permit application.
y
Responsible Designer Name:
L 11
LIt
! F
I�R-e sponslble Designer Signatute
Chad Meyer l /! '�\ 1 t
) 07 t i I t M yer
Company:
RJT Homes R
Date Signed: Ae
12�18�09:4I
2017
Address:
License:
PO Box 810
Codorniz
City/State/Zip:
Phone:
La Quinta, CA 92253
760-564-6555
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 217-P010265023C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:41:04
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-07312017-695
a -.
Easy to Verify
at CaICERTS.com
HERS Provider: CaICERTS inc.
Report Generated at: 2017-12-15 19:32:59
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - P2X Verbena Calculation Date/Time: 18:41, Fri, Dec 15, 2017 Page 1 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz P2X Verbena - Revised 12-14-17.ribdl6x
GENERAL INFORMATION
01
Project Name
Codorniz Plan - P2X Verbena
02
Calculation Description
Title 24 Analysis
03
Project Location
Avenue 52 and Jefferson Street
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpNIgr 2016.2.1 (695)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.1
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
2706
15
Number of Zones
1
16
Slab Area (ft2)
690
17
Number of Stories
2
18
Addition Cond. Floor Area
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ft2)
n/a
21
Glazing Percentage (%)
14.1 %
COMPLIANCE RESULTS-
01
Building Complies with Computer Performance NAWWrMMWWWOftr
if
02
r t 'i k �..s-r rK s.."e!M .rr ,
This building incorporates features that rtiequire field testing and/o'venfication�by a certified HERS rateyr�under the supery soon of a CEC-approved HERS provider.
03
This building incorporates"one or moreSpecial Featuawshown below*' WWW A A 0 411111I01W of
Thiscocompliance analysis?islval d�only fo p rmit applic ti ns th ough..Oct b r 24%2017
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE 1b-06—BY
sar.Q1 n . so to
Registration Number: 217-Po10265009C-000-000-0000000-0000 Registration DateMme: 2017-12-1809:40:29
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
CITY OF LA QUINTA
'kgf0Up11TY tzEVEi0pq;ENT
HERS Provider: CaICER i
Report Generated at: 2017-12-15 18:42:3
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01
Project Name: Codorniz Plan - P2X Verbena - Calculation Date/Time: 18:41, Fri, Dec 15, 2017 Page 2 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz P2X Verbena - Revised 12-14-17.ribd16x
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
0.87 1.14
-0.27
-31.0%
Space Cooling
66.64 51.01
.15.63
23.5%
IAQ Ventilation
0.97 0.97
0.00
0.0%
Water Heating
4.86 4.17
0.69
14.2%
PV Credit
-- 0.00
0.00
--
North Facing Compliance Total 73.34 57.29
16.05
21.9%
Space Heating
0.87 1.65
-0.78
-89.7%
Space Cooling
66.64 49.63
17.01
25.5%
f
IAQ Ventilation
0.97 0.97
0.00
0.0%
Water Heating
4.86 4.17
0.69
14.2%
PV Credit
r --- 0.00
0.00
--
East Facing Compliance
Total--,,, 73.34 56.42
`
16.92
23.1%
Space Heating
-� 0.87 1.41
0.54
-62.1
Space Cooling
64 46.78
19.86
29.8%
IAQ Ventilation
Water Heating
0:97 0'97
4:86 - - 4.17
-•' -
0.00
0.69
0.0%
14.2%
PV Credit
E - 0 00 I
0.00
--
South Facing Compliance Total 73.34 53.33
20.01
27.3%
Space Heating
0.87 0.98
-0.11
-12.6%
Space Cooling
66.64 49.26
17.38
26.1 %
IAQ Ventilation
0.97 0.97
0.00
0.0%
Water Heating
. 4.86 4.17
0.69
14.2%
PV Credit
-- 0.00
0.00
West Facing Compliance Total 73.34 55.38
17.96
24.5%
Registration Number: 217-0010265009C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:40:29 HERS Provider: CaiCERTS inc:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 18:42:34
• CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - P2X Verbena Calculation Date/Time: 18:41, Fri, Dec 15, 2017 Page 3 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz P2X Verbena - Revised 12-14-17.ribd16x
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV '
Final EDR of Proposed Design
North
51.9
44.1
0.0
44.1
East
51.9
43.6
0.0
43.6
South
51.9
42.1
0.0
42.1
West
51.9
43.1
0.0
43.1
❑
Design meets Tier 1 requirement o415% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requiremenYof 30%_or;greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Des ign'DesigCation requirement_ for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
photovoltaic (PV) renewable energy generation sufficienMachieve�a Final Energy Design: Rating'(EDR) of zero or Iess.Jhe PV System must be verified.
REQUIRED SPECIAL FEATURES � �/�. N"QI II N " I I lk -1f t--,07 1111 If \ n
The following are features that must be installed as condition�for meeti• ngithefo mn_ce� imodeted energy perafo5this comput% analysis.:.
� `.+ Y .Y Wii�• Y! �l 4Nr N NY `9-f'' � Y. :Oi.i' :Ya tl 'a
• Cool roof
• Insulation below roof deck
• Window overhangs and/or fins
• Exposed slab floor in conditioned zone
• Non-standard duct location (any location other than attic) '
• Pipe insulation, all lines
Registration Number: 217-P010265009C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:40:29 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 18:42:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CFI R-PRF-01
Project Name: Codorniz Plan - P2X Verbena
Calculation Description: Title 24 Analysis
HERS FEATURE SUMMARY
Calculation Date/Time: 18:41, Fri, Dec 15, 2017 Page 4 of 13
Input File Name: RJT Homes - Codorniz P2X Verbena - Revised 12-14-17.ribd16x
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:' „
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Verified low -leakage ducts in conditioned space must meet maximum 25 cfm leakage to outside (RA3.1.4.3.8)
Domestic Hot Water System Verifications:
• -- None --
BUILDING - FEATURES INFORMATION / o
01
��02s�
03
04
05
06
07
Project Name
Conditioned Floor Area_(ft2)
Number of Dwelling
', Units
Numbe5of Bedrooms.
A, Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Codorniz Plan - P2X Verbena
2706
` 1
T11,%k
; ` 1
? 0
1
ZONE INFORMATION ! tr{
ii1k l�
01
(/ 02 A
H [03 S
R f'04 V f
D Og'—
06
07
-
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
1st Floor
Conditioned
HVAC Split System1
2706
9
DHW Sys 1
Registration Number: 217-P010265009C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:40:29 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 18:42:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: Codorniz Plan - P2X Verbena
Calculation Description: Title 24 Analysis
Calculation Date/Time: 18:41, Fri, Dec 15, 2017 Page 5 of 13
Input File Name: RJT Homes - Codorniz P2X Verbena - Revised 12-14-17.ribdl6x
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door Area (ft2)
Tilt (deg)
Exterior Wall Front N 8x1
1 st Floor
R-13 Wall w/R-5 ESP
0
Front
80
15
90
Exterior Wall Right W 4x9
1st Floor
R-13 Wall w/R-5 ESP
270
Right
36
0
90
Exterior Wall Front N - 6
1 st Floor
R-13 Wall w/R-5 ESP
0
Front
54
18
90
Exterior Wall Left E - 4x
1 st Floor
R-13 Wall w/R-5 ESP
90
Left
36
24
90
Exterior Wall Front N - 4
1st Floor
R-13 Wall w/R-5 ESP
0
Front
72
12.5
90
Exterior Wall Front N - 6 2
1 st Floor
R-13 Wall w/R-5 ESP
0
Front
54
12.5
90
Exterior Wall Rear S - 20
1 st Floor
R-13 Wall w/R-5 ESP
180
Back
183
34.0022
90
Exterior Wall Right W - 1
.1st Floor
R-13 Wall w/R-5 ESP
270
Right
117
72
90
Exterior Wall Rear S 5xl0
1st Floor
R-13 Wall w/R-5 ESP
180
Back
50
15
90
Exterior Wall Right W 15.
1 st Floor
R-13 Wall w/R-5 ESP
270
Right
140
45.0072
90
Exterior Wall Front N 10.
-- 1 st Floor _
R-13 Wall w/R-5 ESP
0
Front
95
0
90
Exterior Wall Right W 15. 2
1st Floor.
�R-13 Wall w/R-5 ESP
270
_ Right
137
15
90
Exterior Wall Front N 22x
j 1st Floor �� w
IR �13 Wall w/R-5 ESP} ;
F ,(1�0
1 (Front
3 198
21.6038
90
Exterior Wall Left E 21.2
, ,/�. 'stFloorR
13 Wall w/R-5 E$P%
A 90
Left
189
27.6
90
Exterior Wall Rear S 5.5x
1�.-
I 1st Flo3o'rs A
f
,��„ - 3 Wall w/R- ESP,!
.. 180 �
Back
v+ 50
0
90
Exterior Wall Left E 7.3x
y
1st Floor-
III t0 l3 Wall w/R- ESPY t
90
L-0 Ceti V-
66
0
90
Exterior Wall Rear S 27x9
1st Floor
R-13 Wall w/R-5 ESP
180
Back
243
72.6
90
Exterior Wall Right W 13.
1st Floor
R-13 Wall w/R-5 ESP
270
Right
121
20
90
Interior Surface to Garag
1st Floor>> Garage_
R-13 Wall
232
17.8
1st Floor Roof
1st Floor
R-22 Roof Attic (Cool Roo
27
2nd Floor Roof
1 st Floor
R-22 Roof Attic (Cool Roo
663
Exterior Wall Front N 13.
Garage_
Garage Exterior Wall
0
Front
125
8
90
Exterior Wall Left 7.5x9
Garage_
Garage Exterior Wall
90
Left
68
0
90
Exterior Wall Front N 9x9
Garage_
Garage Exterior Wall
0
Front
81
0
90
Exterior Wall Left E 21x9
Garage_
Garage Exterior Wall
90
Left
189
0
90
Exterior Wall Rear S 21x9
Garage_
Garage Exterior Wall
180
Back
189
128
90
Garage Roof
Garage_
R-0 Roof Attic
525
Registration Number: 217-P010265009C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:40:29 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 18:42:34
CERTIFICATE OF COMPLIANCE RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01
Project Name: Codorniz Plan - P2X Verbena Calculation Date/Time: 18:41, Fri, Dec 15, 2017 Page 6 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz P2X Verbena - Revised 12-14-17.ribd16x
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type'
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Garage_
Attic Garage Roof Cons
Ventilated
4
0.1
0.85
No
No
Attic 1st Floor
Attic Rooflst Floor
Unventilated
4
0.63
0.85
No
Yes
Inc
s+ ie w,. w
Registration Number: 217-P010265009C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:40:29
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-12-15 18:42:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: Codorniz Plan - P2X Verbena
Calculation Description: Title 24 Analysis
Calculation Date/Time: 18:41, Fri, Dec 15, 2017 Page 7 of 13
Input File Name: RJT Homes - Codorniz P2X Verbena - Revised 12-14-17.ribdl6x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
Window 2660SH - Fen 5
Window
Exterior Wall Front N 8x1 (Front-0)
2.5
6.0
1
15.0
0.30
0.20
Insect Screen (default)
Window 3060SH - Fen 6
Window
Exterior Wall Front N - 6 (Front-0)
3.0
6.0
1
18.0
0.30
0.20
Insect Screen (default)
Wndow 2650SH - Fen 7
Window
Exterior Wall Front N - 4 (Front-0)
2.5
5.0
1
12.5
0.30
0.20
Insect Screen (default)
Window 2650SH - Fen 8
Window
Exterior Wall Front N - 6 2 (Front-0)
2.5
5.0
1
12.5
0.30
0.20
Insect Screen (default)
Window 8 GB - Fen 9
Window
Exterior Wall Rear S - 20 (Back-180)
4.0
.7
0.758
2.0
0.64
0.66
Insect Screen (default)
Window 8 GB - Fen 10
Window
Exterior Wall Rear S - 20 (Back-180)
4.0
.7
0.758
2.0
0.64
0.66
Insect Screen (default)
Window 2660SH - Fen 11
Window
Exterior Wall Rear S - 20 (Back-180)
2.5
6.0
2
30.0
0.30
0.20
Insect Screen (default)
Window 9080 SLDR - Fen 1
Window
Exterior Wall Right W - 1 (Right-270)
9.0
8.0
1
72.0
0.29
0.23
Insect Screen (default)
Window 2660SH - Fen 12
Window.
Exterior Wall Rear S 500 (Back-180)
2.5
6.0
1
15.0
0.30
0.20
Insect Screen (default)
Window 2660SH - Fen 2
Window
Exterior Wall Right W 15. (Right-270)
2.5
6.0
1
15.0
0.30
0.20
1 Insect Screen (default)
Window 2660SH - Fen 3
Window
Exterior Wall Right W 15. (Right-270)
2.6
6.0
0.962
15.0
0.30
0.20
Insect Screen (default)
Window 2660SH - Fen 4
Window
" Exterio5W0II-•Right W t15. z(Rig 270� f
'�M% 2:5 /
7"'16.0
1
15.0
0.30
0.20
Insect Screen (default)
Window 2620FG - Fen 15
Window
ILExterioryWall Right W 1 (Right-270� .�
1111K 2.51
�2.0
I
�5.0
0.28
0.22
Insect Screen (default)
Window 2620FG - Fen 16
Window 'N
�. tea, � �-+ }-a Y-.� :. . � .
�terior Will"Right=W 151. 2 (Right-270)* 1.
` *2.5* f
102F
0 Al A
11111M5�&
0.28
0.22
Insect Screen (default)
Window 2620FG - Fen 17
Window
'Exterior WaIIlRightt-4V 15 (Right-270)
L .5
2.0
D 1
� 5.0
0.28
0.22
Insect Screen (default)
Window 2626FG - Fen 18
Window
Exterior Wall Front N 22x (Front-0)
2.5
2.5
1.008
6.3
0.28
0.22
Insect Screen (default)
Window 2636SH - Fen 19
Window
Exterior Wall Front N 22x (Front-0)
2.5
3.5
1.029
9.0
0.30
0.20
Insect Screen (default)
Window 2626FG - Fen 20
Window
Exterior Wall Front N 22x (Front-0)
2.5
2.5
1.008
6.3
0.28
0.22
Insect Screen (default)
Window 2626FG - Fen 21
Window
Exterior Wall Left E 21.2 (Left-90)
2.5
2.5
1.008
6.3
0.28
0.22
Insect Screen (default)
Window 3050SH - Fen 22
Window
Exterior Wall Left E 21.2 (Left-90)
3.0
5.0
1
15.0
0.30
0.20
Insect Screen (default)
Window 2626FG - Fen 23
Window
Exterior Wall Left E 21.2 (Left-90)
2.5
2.5
1.008
6.3
0.28
0.22
Insect Screen (default)
Window 3050SH - Fen 24
Window
Exterior Wall Rear S 27x9 (Back-180)
3.0
5.0
2
30.0
0.30
0.20
Insect Screen (default)
Window 2626FG - Fen 26
Window
Exterior Wall Rear S 27x9 (Back-180)
2.5
2.5
1.008
6.3
0.28
0.22
Insect Screen (default)
Window 2626FG - Fen 27
Window
Exterior Wall Rear S 27x9 (Back-180)
2.5
2.5
1.008
6.3
0.28
0.22
Insect Screen (default)
Window 3050SH - Fen 25
Window
Exterior Wall Rear S 27x9 (Back-180)
3.0
5.0
2
30.0
0.30
0.20
Insect Screen (default)
Door 3068FR - Fen 14
Window
Exterior Wall Right W 13. (Right-270)
3.0
6.7
1.001
20.0
0.29
0.23
Insect Screen (default)
Window 2040SH - Fen 13
Window
Exterior Wall Front N 13. (Front-0)
2.0
4.0
1
8.0 1
0.30
0.20
Insect Screen (default)
Registration Number: 217-P010265009C-000-000-0000000-0000 Registration Dateffime: 2017-12-18 09:40:29 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 18:42:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - P2X Verbena Calculation Date/Time: 18:41, Fri, Dec 15, 2017 Page 8 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz P2X Verbena - Revised 12-14-17.ribd16x
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door 3080
Exterior Wall Left E - 4x '
24.0
0.50
Door 2868
Interior Surface to Garag
17.8
0.50
Garage Door 16080
Exterior Wall Rear S 21x9
128.0
0.70
- I
T:
k:R
L aslvt -1 -.. 5f nc.
HERS PROVIDER
Registration Number: 217-P010265009C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:40:29 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 18:42:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - P2X Verbena Calculation Date/Time: 18:41, Fri, Dec 15, 2017 Page 9 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz P2X Verbena - Revised 12-14-17.ribdl6x
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
Window 2660SH - Fen 5
1.5
0.1
2
2
0
4
0
3
0
0
0
0
0
Window 3060SH - Fen 6
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 2650SH - Fen 7
4
0.1
4
4
0
4
0
3.5
0
4
0
1.16
0
Window 2650SH - Fen 8
1.5
8.18
2
2
0
0
0
0
0
4
0
4.75
0
Window 8 GB - Fen 9
1.5
8.18
2
2
0
0
0
0
0
0
0
0
0
Window 8 GB - Fen 10
1.5
8.18
2
2
0
0
0
0
0
0
0
0
0
Window 2660SH - Fen 11
1.5 jl
8.18
2
2
0
0
0
0
0
0
0
0
0
Window 9080 SLDR - Fen 1
1.5'
8.18
2
2
0
5
0
1.83
0
0
0
0
0-
Window 2660SH - Fen 12
1.5 ` !
0.1
2
2
0
0
0
0
0
13
0
1.25
0
Window 2660SH - Fen 2
; 1:5
0.1
-2-,
2
0
0
0
0
0
0
0
0
0
Window 2660SH - Fen 3
\`1.5
, `0:1 '
#111111111IF2
2
I*w 0JN%
=rKO'^
ON 1
0
0
0
0
0
0
Window 2660SH - Fen 4
f ,1.5/
�S 0.1 1
2;J
f C2
#00 01me
f 0***
0f 1-1
0r,
0
0
0
0
0
Window 2620FG - Fen 15
1.5 "
00.1 '
111111102
11 2)hpp
i*Wdl V
10' 0**0
019 1
1051140
10 0
4
0
1.91
0
Window 2620FG -Fen 16
i` 1.5
1
H2 F
R241t<0'
R
r0 J
0n
iF 0R
0
10.45
0
4.91
0
Window 2620FG - Fen 17
1.5
0.1
2
2
0
0
0
0
0
10.45
0
7.91
0
Window 2626FG - Fen 18
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 2636SH - Fen 19
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 2626FG - Fen 20
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 2626FG - Fen 21
1.5
0.1
2
2
0
0
0
0
0
0
0 1
0
0
Window 3050SH - Fen 22
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 2626FG - Fen 23
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 3050SH - Fen 24
1.5 1
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 2626FG - Fen 26
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 2626FG - Fen 27
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 3050SH - Fen 25
1.5
0.1
2
2
0
0
0
0
0
0
0
0
0
Door 3068FR - Fen 14
1.5
0.1
2
2 1
0
0
.0
0
0
0
0
0
0
Registration Number: 217-Po10265009C-000-000-0000000-0000 Registration Dateffime: 2017-12-18 09:40:29 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 18:42:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - P2X Verbena Calculation Date/Time: 18:41, Fri, Dec 15, 2017 Page 10 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz P2X Verbena - Revised 12-14-17.ribdl6x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value.
U-value
Assembly Layers
• Inside Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x4
Garage Exterior Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.361
Exterior Finish: 3 Coat Stucco
Ceilings (below
Inside Finish: Gypsum Board
R-0 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
none
0.481
Cavity/Frame: no insul. /2x4
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Garage Roof Cons
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Cavity / Frame: R-9 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof1 st Floor
Attic Roofs `
Wood Framed Ceiling
in. O.C.
R 9
0.103
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Cavity/Frame: R-13/2x4
Sheathing / Insulation: R5 Sheathing
R-13 Wall w/R-5 ESP
Exterior Walls
Wood FramedWall
2x4 @ 16 in. O.C.
R 13
0.063
Exterior Finish: 3 Coat Stucco
Ceilings (below.,,
1(..4
Inside Finish: Gypsum Board
Cavity/Frame: R-9.1 /2x4
R-22 Roof Attic (Cool Roo
attic)/, '
Wood Framed:Ceiling
,@ 16 In. O.C.
R 22
O�Q43�
Over Ceiling Joists: R-12.9 insul.
1 f
�"
T�,,.,i
1 i
T#P
• Inside Finish: Gypsum Board
Cavity/Frame: R-13/2x4
R-13 Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.092
Other Side Finish: Gypsum Board
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab -on -Grade
1st Floor
217
24
None
1
No
Slab -on -Grade 2
1st Floor
473
58
None
0
No
Slab -on -Grade 3
Garage_
525
0.1
None
0
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
--
Registration Number: 217-P010265009C-000-000-0000000-0000 Registration DateMme: 2017-12-18 09:40:29 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 18:42:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - P2X Verbena Calculation Date/Time: 18:41, Fri, Dec 15, 2017 Page 11 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz P2X Verbena - Revised 12-14-17.ribdl6x
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1 (1)
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
Tank
Energy
Tank Insulation
Tank Location or
Heater
Number
Volume
Factor or
Input
R-value
Standby Loss /
Ambient
Name
Element Type
Tank Type
of Units
(gal)
Efficiency
Rating/Pilot
(Int/Ext)
Recovery Eff
NEEA Heat Pump Type
Condition
DHW Heater 1
Gas
Instan a Small
1
0
0.94 EF
199,000 Btu/hr
R-0
n/a
0
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC Split Systeml
�.
Other Heating and Cooling
". System, i
Heating Component 1
i= r=4k
Cooling Component 1
1 n
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES ''j_ �\ K r,-e -1 _4 f I I kk t l� I�� I f '11� 11 K i l ff
01
2J ti,.,""''� b-27=3 U U_ U i 'I' j k
U Uk 08 �" V
04
Name
H System Type i, kJ V J t
) Nu ber4'of Units
Efficiency
Heating Component 1
CntrlFurnace
1
92 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Name
System Type
Number of Units
Efficiency
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
1
12.5
15
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Registration Number: 217-P010265009C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:40:29 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 18:42:34
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: Codorniz Plan - P2X Verbena
Calculation Description: Title 24 Analysis
Calculation Date/Time: 18:41, Fri, Dec 15, 2017 Page 12 of 13
Input File Name: RJT Homes - Codorniz P2X Verbena - Revised 12-14-17.ribd16x
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
Lowl-lCod
Sealed and tested
6
Conditioned zone (VLL)
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
See RA3.1.4.3.8
Required
Not Required
Not Required
Not Required
—
HVAC -FAN SYSTEMS A
01
02
03
04
Name f f
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1 �-� _:_ !
1_: ='""Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS -HERS VERIFICATION' 1
#
01 ! / ,.��/ i
g g p gK j
1. 11 1 9 f02 l l
03
Name '
1 ' �` ,'�.
` == p rinfied Fan Watt Drawl 1k `
,
Required Fan Efficiency atts/CFM
q y (W )
HVAC Fan 1-hers-6A "*-A
H e R S Reequired V 1 0 e R
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
57
0.25
Default
0
Required
Registration Number: 217-P010265009C-000-000-0000000-0000 Registration Date/Time: —' 2017-12-18 09:40:29 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-12-15 18:42:34
� CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Codorniz Plan - P2X Verbena Calculation Date/Time: 18:41, Fri, Dec 15, 2017 Page 13 of 13
Calculation Description: Title 24 Analysis Input File Name: RJT Homes - Codorniz P2X Verbena - Revised 12-14-17.ribdl6x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
"d cc7M,
Michele J'Kler
Company:
Signature Date:
Advancing Home Performance, Inc.
2017-12-16 15:46:39
Address:
CEA/HERS Certification Identification (If applicable):
74998 Country Club Drive.
City/State/Zip:
Phone:
Palm Desert, CA 92260
760-851-8648
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted the enforcement,agency for approvalwith,thi building permit application.
Responsible Designer Name:
C
iResponslble'Designer Sig atu�ei
C�a Dyer
Chad Meyer - /'
Y /� .�
. t� � 0%
Company: M
RJT Homes b' R S
Date Signed: 'W
12
2017 18 09:4I0:29
Address: _
License:
PO Box 810
Codorniz
City/State/Zip:
Phone:
La Quinta, CA 92253
760-564-6555
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 217-Po10265009C-000-000-0000000-0000 Registration Date/Time: 2017-12-18 09:40:29
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-12-15 18:42:34