Loading...
0311-015 (ELEC)LICENSED CONTRACTOR DECLARATION hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date 762799 A 05t31/,t( Date �� �f/. Signature of Contracto _ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( )' I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier STATE FUND Policy No. 1557214-02 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation n provisions of Section 3700 of the Labor Co"de, I shall forthwith comply with those provisions. bate:., - Appicanta-..-r Warning: Failure to secure ' Worke Compensation coverage is unlawful and shall subject an employer to"criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is - correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes. / Signature (Owner/Agent)— -I- ^" - Date 1 BUILDING PERMIT PERMIT# 0311-015 DATE VALUATION ppyq LOT TRACT : 'e Pl.7,Oi1(trtJO ptli' i/J[•�rf% JOB SITE ADDRESS 7.q-294— I/2 H%VY 13 APN OWNER CONTRACTOR/DESIGNER/EN (NEER &rAMXO xiEMOP7v4 ENT CO. SfAMK0D1'`'ti TAP'Mk.L' T CO. 2205 n PODTI TI7A AIM :3856 VIAT OUM MANHATlA,N BEACH CA 90266 MA I)'8L MY CA 90292 (310)SZI.6161 CBL# 2172 USE OF PERMIT.Ry c.T laWl SITZ UCtHT)rN(3. 1 s &A AT PAR,C.I!I.S 7 et 1� MAT PARC ELS Z3 &4 PER APPROVED PLANSI/€ MUC` URAE, CALC3,200! CBC., VALUATION 1910M.00 I,S 19MM,, . C0b7' 0.' C011IM'RI 'C."113 ON 17.00 IDD PIAN CHECK FEE 101-000-439-1.144 $117.00 CONSTRUCTION 1E& 101-•000-418-000 $180.00 EL EC TIUCAL FEE 101.000.420.000 $33.00 STRONG MOTION IEE - COMM 100-M.0-241-000 33.57 -TOTAL. CONSTItLJ`MON AND PLAU GTS. K $333.51 Las PIM -PAM I $0,00 T01Ai.. rEwid 'L' FYLS J5133"P.' NOW - =14 S7 CiL Q 1 2423 J RECEIPT — DATE DAT9 F ALE INSPE R RECORD OPERATION DATE tl�i TOO 00' OPERATION 7DATE 1144P -AP� ALS: BUILOING PROV A11pP ,FO MECHANICAL V4& Set. Backs Underground:Du cts Forms & Footings Ducts Slab'Grade Return Air � 'Sfeell Combustion Air RoQf. Deck Exhaust Fans O.K. to Wrap F.A.U. Frarfing Compressor Insulation Vents ,"..Fireiplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final POOLS -SPAS BLOCKWALL APPhOVid_S Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste:Lines Heater Final Water Piping .j Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover 'Sewer Connection z. Encapsulation Gas. Poing' Gas Test ,Appliances Final COMMENTS: T V: c. Final Utility Notice (Gas) RO ELECTRICAL Af)f'RO LIS' jemp.0owtOole �.Undergroundtonduit 'pough Wiring '-Low Voltage Wiring Fbdures, Main Service Sub Panels E;ieri4r Receptacles, G.F.I. Smo7k'o Detectors Temp.- Use of Power Final Utility Notice (Penn), 4 19 A X Bin # City of La Quinta Building 8z Safety Division Permit # P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: S L Owner's Name: �jvl�r-c. I., lnJ i 1ti�, z A. P. Number: Address: �c? j� 4 y z),d Legal Description:'(City. ST, Zip:L l� 5 E &:7=r4�, ZZ� Contractor: ST,4 Lo P ^fl r N"T FTelephon :'f ler) 7 �q O lGj �- Address: -P0 F� 0- X /-y �"1� c� Project Description: City, ST, Zip: PAJ-- ✓( �!✓S� 11�T, G/1 CI 5 j� ��C� 2.� i LI I-+ rs Telepho a 1(_0 D ( , �. _ �/f .G - U l i ' S State Lic. # : City Lic. #: Arch., Engr., Designer: Address: City, ST, Zip: Telephone:S-7 - { ' • .,.'•:.,. -•,.. _ .'-: ,.:::rt= Construction Type: Occupancy: State Lic. #::h." Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: DA n/ JAC-cl g S 5 0 N X Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: -? 6b3 Z7 5 ^ � � stimated Value of Project.DU U APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Req'd TRACKING PERMIT FEES Plan Sets Plan Check submitted 14- Q /L Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Cafes. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for correctioue iss , Z p Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '^' Review, readv for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A I p p Pub. Wks. Appr Date of permit issue School Fees r-- Total Permit Fees 3, "--V C'M Cs 2iUw oG lG,LiuGdw P.O. BOX 1504 BUILDING & SAFETY DEPARTMENT 78-495 CALLS TAMPICO (760) 777-7012 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 To: Greg Butler, Building & Safety Manager - -To CDD: 10-28-2003 From: Oscar Orci, Planning Manager Due date: 11-3-03 Status:1 st Review y Building Plans Approval . (This is an approval to issue a Building Permit) The Community Development Department has reviewed the Building Plans for the following project:. Description: Site Lighting for Parcels 2,3,4,7,8. Address or general location: 79-295 Highway 111 Applicant Contact: DanJacobsson 760-275-4064 The Community Development Department finds that: ❑ these Bing Plans do .not require Community Development Department a a. ...these Building Plans are approved by the Community Development Department. ❑ ...these Building Plans require corrections.. Please forward a copy of the attached corrections to the applicant. When the corrections are made please return them to the Community Development Department for review. v /den ®� Orci, Pla.Aning Manager ate r• YOUNG ENGINEERING SERVICES -,Engineering •Architecture•Surveying• Building & Safely Services Letter of Transmittal To: %u A:: �L Q�a�".QrL� — Date: Project: Attn:PC#: Tel No.: Tract No.: We are forwarding: By Messenger No. of Copies Description: � J r •I �� . i wid—Is By Mail Your Pickup Comments: This Material Sent for: Your Files Per Your Request Your Review Approval, Checking At the request of: Other By: 0iY_ sl)t ' Phone # 77-404 Wildcat Drive, Suite C, Plam Desert, C4 92211 (760) 360-5770 Bronz Young �phq Earth Systems Southwest Project: Light Standards for The Centre, in La Quinta CA Project No: 08628-03 Date: 03/19/03 Calculation By: Shelton L. Stringer, GE FOUNDATION LOAD ANALYSIS OF 34 -FT HIGH LIGHT STANDARDS by 2061 CBC Basic Wind Speed Exposure:�4��5,�! v4 k DI mph Lateral Wind Load govern Design Wind Stagnation Pressure qs4 ;;r12°6 psf - ` from Table 16-F Importance Factor Iwr ; "t1 00ti from Table 16-K t Pressure Drag Coefficient C aa'1.4,U from Table 16-H Exposure Pressure Height Height Projected Lateral Bending Ce p from Ground from Base Pole' Area Force Centroid`` Moment t Table 16-G CeCggslw h H Diameter PA P " x "M psf feet feet inches: sf lbs' feet ft -lbs d °vr'2 5 0 x sg r5p Pole (0-15 ft) 1.06 18.7 15 12.5 6.6% 7.9 y 147 '„ 8.75.1286-' Pole (15-20 ft) 1.13 19.9 20 17.5 5.8 2.6 52 17.50 902 'Pole (20-25 ft)' 1.19 21.0 25 22.5 5.1, 2.3' 48 "22.50 1070 y Pole (25-30 ft) 1.23 21.7, 30 27.5 , 4.3 1.9 42 27.50 1161 Pole (30-40 ft) 1.31 23.1 34.5 X3248 ` ;�� 3 6' � " 15 34 32.25 :1102' L Fixture 1.31 23.1 36.5 i,f, 34.4 z! F?. a4.0 ±:,; 92 36.50 3374 Totals 20.1 415,. .' 21.4 8895 ' FOUNDATION DESIGN ANALYSIS Hoftontal Load H = Fi 0s415 kips Foundation Diameter D _ �`�2 O'feet •' y Foundation. Depth L = }fi,`�ryhr, 6"Ofeet Effective Application Height e = s d rF21s;4yfeet y . . -, .94Lae131 .Ca�cI.b Brms 16n ,.;. r,. Average Density of Soil y _ i'Wi�F � 100) pcf . �Ayerage Friction angle _ .r rx 4 Y �4 �301degrees conservative value for loos se state''' Rankine Passive Coefficient KP = = tan 2 (45 ° + 02) -level ground QROF ESS/pN ' = Passive Effect. Fluid Presure EFPp ' = 3.00 Q�0 ON L. ST q�F• �``/ 9�2 2� • yKp I�3 G� 2 - 300 Oct c� Passive Pressure @ base pb _, = '++. cn Nb.2266 ]mo m 3 yDLKP ` • `� 22 Exp.. 04 'psf 5,400 _ :4: Ultimate Passive Force Pp = 1.5 rDL Z K p `r� cFCrECHN��'P��Q S"r `r� k Sf rG'.f>Af A% 32 kips gTFOf A`1FOQ� +l'A^T-'iDr,)3fE'C '�. �E M�jl}�9%'4�''r] 7:}. k�'�dnc•sR.:'.+'ilyF'... ti y 4,� r�,��.�Moment Equilibrwm�•�,tr� FSv� k,, ,� �'-�y''�i•`'' yr,;,�11a5'�.a sm ^^{ .".cyrr 91 ,a'�xSni... .�'yF"�''�"�� � � �,yxv'C� `yry�r� ' �� .�'LIsicr3J°� ''J7�k _ 5 C''°�, y§S„bg�%}`• Jr'l� %�kY; ��� _ ��Mr/Md .�(0 5 yDL�'Kp)/H(e+L�) ��M�,��,�+,j}-��,�v. 'x`�, 4,+.�: } ,tf k•„�ari` 9L'"`•, Fila r�}sd�d�$i�r,F io:154�}{i+W is ,�. �Z�, F xi T' +� 'i td 4 w7 4'.�.,kJ .+• "�" � ..-�• i ?3 '�`y�t3 �.�i � �3 �, �i��'in^''i..4'�,i�:t� sFr •r �` Moi FS d +Mr '`0�'i,*34',a;+t-fir,„*cv 1� `�r�:• � ,.- S + ,,, ��„ .sa � a �i` ..',��,�t���.,.z�..�` •�h „(M ).�., ..x.�.. �',�s,�sti,.��.�� cy���x:F .�-��«. ,{fix , � ��5 �•�; �~ .�: ,s�...t��f,<�;s�. 3r��OkaY,�t>;. „�t Applied Lateral Load; 'P = 415 lbs Short-Term/Permanent, '. ? _ '� 2 -Enter (1) Permanent, (2) Short Terni Xi. Lateral Soil Bearing, S= psf/ft (from Table 18 -I -A) . S1 = . - 600 psf = S*d/3 for d < 12 ft, else 4*S S3 = ;. i 1,800 psf = S*d ford<12, 12*S ford>12 .,'. . Foundation diameter, b= 'r 2:0.0 ft s Application height, h = -'� : 21.4, ft A _ *P/(S1*b .,'. 0 81 ft = 2.34 ) Trial depth,-, d -' - , _ z 6 s �0 ft (if less than 12 ft, otherwise ente'r 12) Req'd depth-nonconstr, o do = _ . .' } „ 4.8 ft = A/2*(1+SQRT(1+4.36'h/A)) Okay Allowable Deflection,' „ ,:,, ya =' 0.5 inches Overturning Moment, M = 8.895 ft -kis = P*h [" PY1:; L k'a. _- a,: l i*u .,...r kid, ..-..a..A. .de-� ..s,.r.'3. ...,I ..d ... . ?cr.. ..... .... „r,:,... .eX.. w...: ,+•t... ?,.. 1,..... C -i:... \'". �,....1 J_ -a. ..iF.n _<i'i's.a� t]. -3:$b...''?' F�.E ._ ?Iv(Y ,�.tiFS tt „.. R..,..?f. . Compressive Strength t'c' "< ,, `3 500} psi Pier Moment of Inertia Ic = 1.63E+04 5n° _ ,rD4/64 • Neutral Axisc = 12 in Bending Moment M = 106739 in -lbs ' Extreme Bending Stress: fb 79 psi _ MGI Tensile Strength ff _ 136 psi _. 2.3fco-5 ' FS 1.73 , Okay, No reinforcement required", x,12' S' TAPERED POLE B CONNECT ALL EQUIPMENT• PER SPECIFICATIONS. POLE GROUND CONDUCTORS TO SHALL BE MADE PLUMB WITHGROUNDING LUG IN POLE LEVELING NUTS. ORARY CAP ALL CONDUIT HAND HOLE WITH COVER V 1'-6" FROM BASE OF POLE. ' 9"x 6" MIN. OPP.ERWELD GROUND ROD ' D TO EQUIPMENT GROUND AT GROUND LUG'IN POLE DETAIL "C" PROVIDE JUNCTION BOX ON 37 POLES WITH SECURITY A A CAMERAS ONLY. REF SITE PLAN FOR SECURITY 0 4) ANCHOR BOLTS 1-1/4" DIA.i POLE LOCATIONS 42" LONG x 6" HOOK WITH 2 FINISH GRADE NUTS, 2 FLAT WASHERS AND 1 ' LOCK WASHER EACH �• ' .. • N CONDUIT AS 4-#8x8' (MIN) LONG BARS REQUIRED EQUALLY SPACED , (i" MIN) c z_ y3.TIES ® 16" O.C. MAX VERTICAL AND HORIZONTAL BARS SHALL BE.FIELD TIED. 3" MINIMUM COVER TYP WELDING NOT PERMITTED. SUPPORT REINFORCEMENT IN t ITS PROPER LOCATION FROM THE FORMWORK DURING _ CONCRETE OPERATION. N Z 2' BELOW FROST LINE 24 - DIAMETER NOTES: I. 3500 PSI MIN. 28 DAY COMPRESSIVE STRENGTH CONCRETE WITH GRADE 60 REINFORCING STEEL J 2. IF WATER. IS PRESENT IN HOLE, REMOVE BEFORE POURING CONCRETE S. • FOUNDATION EXCAVATION SHALL BE BY 24' AUGER IN UNDISTURBED OR PROPERLY COMPACTED !J FILL PER SPECIFICATIONS. 4. FOUNDATION SHALL HAVE A MINIMUM ALLOWABLE END BEARING OF 2000 PSF. FOUNDATION HAS BEEN DESIGNED FOR A COHESIVE SOIL BASED ON A MINIMUM COHESIVE VALUE OF 1000 PSF. 5. FOUNDATION HAS BEEN DESIGNED FOR A GRANULAR SOIL BASED ON A MINIMUM LATERAL SOIL PRESSURE OF 1000 PSF, UTILIZING AASHTO FIGURE 1.8.2C(4)' OF "EMBEDMENT OF POSTS WITH OVERTURNING LOADS'. �. EXPOSED CONCRETE SHALL BE PAINTED TRAFFIC YELLOW. 1. DETAIL FOR 39' POLE (MAX) WITH MAX. FIXTURE EPA 4.6 SQ.FT. #3 TIES AT 16" O.C. 5/8"x 12' (MIN) COPPERWELD GROUND ROD CONNECTED TO EQUIPMENT GROUND WIRE AT ERTICAL .4-#8 VERTICAL---. GROUND LUG IN POLE REINFORCING . BARS PLACED INSTALLATION IN CONCRETE ADJACENT TO PAVING REQUIRES CONTINUOUS ANCHOR BOLTS 1/2" EXPANSION JOINT MATERIAL ALL AROUND. SEAL WITH JOINT SEALER PER SPECIFICATIONS CONDUIT AS REQUIRED JUNCTION BOX (SECURITY POLES SECTION "A -A" ONLY), LOCANDBETWEEN SECOND TIES MON S y�q�A�+C" ®�EgpNgpGgQIN MOR E . C!o"ll' JGCJ'tl l7'CJO .. P61_E-T6-bASE PLATE WELD SHALL COMPLY WITH AWS ANCHOR SPECS. AT TOP AND BOTTOM BOLTS OF BASE PLATE BASE PLATE BOLT HOLE T4Y5P ' POLE BASE PLATE ND 0'-3 3/4' BOLT PATTERN PER MANUFACTURER'S RECOMMENDATION o 1 \_ LIGHT FIXTURE ORIENTATION 24" DIA. CONCRETE FOUNDATION (SEE SITE PLAN FOR ORIENTATION TO BUILDING) JUNCTION BOX (SECURITY POLES ONLY), FLUSH WITH FACE OF LIGHT POLE BASE. LOCATE JUNCTION'BOX TOWARDS FRONT OF BUILDING. BOLT' COVER TYPICAL REF SPECIFICATIONS SECTION "B-B" HANDHOLE WITH COVER REMOVED BURNDY COPPER #KPA4C GROUNDING LUG WELDED SCRULUG AND TIN PLATED TO INSIDE OF POLE NUT AND BOLT OR BURNDY TWO PIECE BOLT COPPER #KC20 SERVIT ATTACHED TO ROUNDING LUG COVER REQUIRED HED GROUND TO CR LOCKING WASHER. GROUNDABLE D NUT 5" MIN. 5.5" MAX LEVELING NUT WASHER BOLT PROJECTION (MAX 1" FROM CONCRETE) BASE PLATE PER SPECIFICATIONS DETAIL "C" ANCHOR BOLT N 12 1/2" BOLT CIRCLE � as RgD�V uQi TYPICAL ANCHOR BOLT SPACING IGHT POLE BASE DETAIL. Earth Systems Southwest Project: Light Standards for The Centre, in La Quinta, CA ." '� Project No: 08628-03 Calculation By: Shelton L. Stringer, GE ' Date: 03/19/03 ' FOUNDATION LOAD ANALYSIS OF 34 -FT HIGH LIGHT STANDARDS by 2001 CBC Basic Wind Speed * x v,7M mph Lateral Wind Load govern Design FY . ExposureYC }; Wind Stagnation Pressure MEW tiA psf gsyws�,from Table,16-F • Importance Factor Iwsv,s µUOQ from Table 16-K - Pressure Drag Coefficient Cq 74, from Table 16-H Exposure Pressure T Height Height Projected Lateral Bending Ce p -,from Ground from Base 'Pole Area ' Force Centroid Moment ' Table 16-G CeCggslw h H Diameter PA P x' M r.psf feet feet inches. sf lbs feet ft-lbs r 245J 0 sr`grjr Pole (0-15 ft) 1.06 18.7 15 '12.5 6.6 7.9 147 8.75. 1286 Pole (15-20 ft) 1.13 19.9 X20 17.5 ° 5.8 < f 2.6 52 17.50 902 Pole (20-25 ft) 1.19 21.0 25 _ 22.5 5.1 2.3 48 22.50 1070 Pole (25-30 ft) 1:23 21.7 30 r - 27.5 4.3 1.9 42 27.50 1161 Pole (30-40 ft) 1.31 23.1 34.5 m32� "` 3 6°` 1 5 34 32.25' 1102 Fixture 1.31 23.1 36.5x34` 92 36.50 r 3374 Totals 20.1 415 21.4 8895 FOUNDATION DESIGN ANALYSIS ' Horizontal Load H 'D Ikips #�2 (feet • • Foundation Diameter _ Foundation De p th L ` ' _ '���,s, f6Qfeet ''`2v Effective Application Height e Ngjwj2afeet Latex,- Sr -r .:t ,, ;m..�. cYi 6 r '�.. ,y Y -'* { ' at a 2 9 5 e"•''fE,..ry* e-• 3 t+` .a ' i`r ."ral�1 oad�C,a aci b..:Broms.t --_ ;,method: x r� rK�{,�,..�,�,•�.....;:<L�.,�:.�z��.'� �_..��^ r,° .a.5.,:�'.. i,,. Y Ana. .��>a.�l��;... , c.... �,{��,.r..,: �Average Density of Soil _ y ` Q pcf �° L Average Friction angle = g g ._ _5, 30 degrees conservative value for loos se state Rankine Passive Coefficient Kp ;: _ • tan' (45 ° + 2) -level ground QbLOFESSIpN Passive Effect. Fluid Presure EFPp. r 3.00 ^ . QUO Ort L. ST ql�, ' �y .; Y4 c X2266 - _ '' F rn '3 rDLK, 300 pcf r � U) No. 2266 m }Passive Pressure @ base - pb = Exp. 6-30-04 • ,, , w .5,400 psf � � t Ultimate Passive Force Pp 1.5 yDL KP LP �P �cw4ikC'k 32 kips 9TFOF A Wfj' 4 k . d-=: L .r1i ` s+k�" 2h<Gc'i ,'i'^^'6-ia . ' Ta j 7' y "•.vo""3y� Moment EquU,brium FS (t t ' •<`��P ,f *r'S- y e��;tot' �' l "'A� r al M`/ d 6 DL �p /I Z s' mss, tik' (k 1,sf�r7 P ") r1� * °» '•'{ { f* f- :p ,7`_fv L„ ���r�k..$�q'eS,r�'u�� - 1++Y iC� �Moc FS d) -Q y� c t`�i . + i .n 'kF'. �. `�,'�G w:_h r aaxtst v am .>•,<:w�,. .sn�..� .�,...�..,�,...�,� �s. �,�>-�.�:r,.� ,[ i- ..��5 er} �x� -ter �� ,? '�3Cc. �,�OkaYs��Y *a LateralSBeari ;a_'nd _Desi n?c"riteriataken"fromCBCSection,1806: 72�Spur �, ;"ss,h �?u ? F`k? �;; Applied Lateral Load, P = 415 lbs ' Short-Term/Permanent, ? 2 - Enter (1) Permanent, (2) Short Term '. ' Lateral Soil Bearing, S=' Y.". , -J X 1'50' psf/ft (from Table 184-A) - S1 600 psf = S'd/3 ford < 12 ft, else 4'S ry S3 = 1,800 psf = S'd for d<12, 12'S ford>12 Foundation diameter, b = 2.00 ft r Application height, - h = , 21.4 ft A = : ; r . 0.81 ft = 2.34'P/(S1•b) Trial depth, .d = 4 ft if less than 12 ft, otherwise enter 12 : Req'd depth-nonconstr, do = w 4.81ft' = A/2'(1+SQRT(1+4:36"h/A)) Okay t Allowable Deflection, ' ya = 0.5 inches 1 I( j�.G d. 'Overturning Moment, M= 8.895 ft -kis P'h j i = cTi� ii{,•rivE��� ;�..:y{�.•:.F�.,i;:.,-F•.� ,�.. a15�1�-t�e!F/, ..+,v.h.:. }. � ai Yz 'i ,r ,:�I, 3:1. t.'FC7.i. i'Ok+/ 1 c•_ , Compressive Strength tc � Kpsi. - CITY OF LA 'QUINT Pier Moment of Inertia " Ic : = 1.63E+04.in4, _ > >rD4 646UILDING SAF 1(.DEP Neutral Axis c . 12 in ' Bending Moment M s 106739 in -lbs -' •` APPROVED Extreme Bending. Stress - tb 79 psi = Mc/I ", o.e r'FOR CONSTRUCTION � Tensile Strength ft ' " 136 psi 2.3f ' ,; GD FS ` 1.73 Okay, No reinforceme t re uire • ., •` � '',5 y T1 : " a.t. r�; arr;,. -. `' - .{^J - •;1 • v.. C aLl - I,, � ... e. • ` '• r, . r'� •.. ��: �� �,rrr . ti's 'I� � - ,i Ilr � � �' , )0' S'EL TAPERED POLE IB CONNECT ALL EQUIPMENT PER' SPECIFICATIONS. POLE B GROUND CONDUCTORS TO SHALL BE MADE PLUMB WITH GROUNDING LUG IN POLE LEVELING NUTS. TEMPORARY CAP ALL CONDUIT HAND HOLE WITH COVER V -6 -FROM BASE Of POLE. ' 9"x 6" MIN. 5/8"x 12' COPP.ERWEID GROUND ROD CONNECTED TO EQUIPMENT GROUND WIRE AT GROUND LUG 'IN POLE DETAIL "C" N PROVIDE JUNCTION BOX ON POLES WITH SECURITY A A CAMERAS ONLY. REF SITE " • PLAN FOR SECURITY n(4) ANCHOR BOLTS' 1-1/4" OIA.z POLE LOCATIONS 42" LONG x 6" HOOK WITH 2 FINISH GRADE NUTS, 2 FLAT WASHERS AND 1 LOCK WASHER EACH. tR �,.. fV 4-#8x8' (MIN) LONG BARS CONDUIT AS . EQUALLY SPACED REQUIRED (1" MIN) c . � #3. TIES ®16" O.C. MAX VERTICAL AND HORIZONTAL BARS SHALL 8E. FIELD TIED. 3" MINIMUM COVER. TYP WELDING NOT PERMITTED. SUPPORT REINFORCEMENT IN ITS PROPER LOCATION FROM THE FORMWORK DURING _ CONCRETE OPERATION. 2' BELOW FROST LINE 24' DIAMETER NOTES: 1. 3500 PSI MIN. 28 DAY COMPRESSIVE STRENGTH CONCRETE WITH PRADE 60 REINFORCING STEEL 2. IF WATER. IS PRESENT IN HOLE, REMOVE BEFORE .POURING CONCRETE S. FOUNDATION EXCAVATION SHALL BE BY 24" AUGER IN UNDISTURBED OR PROPERLY COMPACTED FILL PER SPECIFICATIONS. ' t. FOUNDAIIO14 SHALL HAVE A MINIMUM ALLOWABLE END BEARING OF 2000, PSF. 'i. FOUNDATION HAS BEEN DESIGNED FOR A COHESIVE SOIL BASED ON A MINIMUM COHESIVE VALUE OF 1000 PSF. i. FOUNDATION HAS BEEN DESIGNED FOR A GRANULAR SOIL BASED ON A MINIMUM LATERAL SOIL PRESSURE OF. 1000 PSF, UTILIZING AASHTO FIGURE 1.8.2C(4) OF "EMBEDMENT OF POSTS WITH. OVERTURNING LOADS'. �. EXPOSED' CONCRETE SHALL BE PAINTED TRAFFIC YELLOW. t. DETAIL FOR 39' POLE (MAX) WITH MAX. FIXTURE EPA 4.6 SQ.FT. #3 TIES AT 16" O.C.5/8"x 12' (MIN) COPPERWELD GROUND ROD CONNECTED TO El GROUND WIRE AT 4-#8 VERTICAL GROUND LUG IN POLE . REINFORCING BARS PLACED INSTALLATION IN CONCRETE ADJACENT TO PAVING REQUIRES CONTINUOUS ANCHOR BOLTS 1/2" EXPANSION JOINT MATERIAL ALL AROUND. SEAL WITH JOINT SEALER PER SPECIFICATIONS !' CONDUIT AS REQUIRED JUNCTION BOX (SECURITY POLES ONLY). LOCATED SEB COND TOP SECTION "A -A" EES' JMoo E ' INEENG 1 v 1 A. �Cllucno POLE- `✓?OaBASE PLATE WELD • SHALL COMPLY WITH AWS A ANCHOR SPECS. AT TOP AND BOTTOM BOLTS OF BASE PLATE BASE PLATE BOLT HOLE 45' TYP POLE BASE PLATE0 0'-3 3/4' BOLT PATTERN PER MANUFACTURER'S RECOMMENDATION o . \_ N p' LIGHT FIXTURE ORIENTATION -/24' 'DIA. CONCRETE FOUNDATION (SEE SITE PLAN FOR ORIENTATION TO BUILDING) JUNCTION BOX (SECURITY POLES ONLY), FLUSH WITH FACE OF LIGHT POLE BASE. LOCATE JUNCTION'BOX TOWARDS FRONT OF BUILDING. BOLT COVER TYPICAL REF SPECIFICATIONS SECTION "B -B" HANDHOLE WITH COVER REMOVED BURNDY COPPER #KPA4C GROUNDING LUG WELDED SCRULUG AND TIN PLATED TO INSIDE. OF POLE NUT AND BOLT OR BURNDY TWO PIECE BOLT COPPER #KC20 SERVIT ATTACHED TO GROUNDING LUG COVER REQU IRED #4 GROUND.CABLE ATTACHED LOCKING WASHERAT' TO GROUND ROD NUT 15- MIN, 5.5' MAX LEVEL WEER BOLT PROJECTION (MAX CONCRETE) BASE PLATE PER SPECIFICATIONS DETAIL "C" ANCHOR BOLT N h1 12 1/2' BOLT CIRCLE 4. . r• • TYPICAL ANCHOR BOLT SPACING IGHT POLE BASE DETAIL