Loading...
BPOL2020-000178-495 CALLE TAMPICO Tiht DVOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Permit Type/Subtype: POOL/PRIVATE Owner: Application Number: BPOL2020-0001 BRIDGET SMITH Property Address: 54278 INVERNESS 54278 INVERNESS APN: 775101020 LA QUINTA, CA 92253 Application Description: SMITH / POOL AND SPA AT REAR YARD Property Zoning: Application Valuation: $35,000.00 Applicant: Contractor: J B POOLS D J B POOLS 84400 ONDA DRIVE 84400 ONDA DRIVE INDIO, CA 92203 I AN 6 3 2020 INDIO, CA 92203 CITY Of l�lQ1�4NTA (760)413-3023 LIc. No.: 1021763 DESIGN &DEVE49PMENTDEPA�TMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C53 License No.: 1021763 Date: 1 ;ice 62a Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: () I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) 1, as owner ofthe property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: Date: 1/3/2020 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of thie�jnrk for which this permit is issued. r— 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: ACEAMERICAN INSURANCE COMPANY Policy Number: C66356085 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: lf' . Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon thR above - mentioned property for inspection purposes. , I Date: / -3 —.-7 a Signature (Applicant or Agent) Date: 1/3/2020 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: J B POOLS 84400 ONDA DRIVE INDIO, CA 92203 BPOL2020-0001 54278 I N V ERN ESS 775101020 SMITH / POOL AND SPA AT REAR YARD $35,000.00 Owner: BRIDGET SMITH 54278INVERNESS LA QUINTA, CA 92253 Contractor: J B POOLS 84400 ONDA DRIVE I N DI O, CA 92203 (760)413-3023 Llc. No.: 1021763 Detail: POOL, SPA, AND FIRE PIT AT REAR YARD [DENISE POELTER ENGINEERING.] NEW EQUIPMENT MUST BE LOCATED IN AN APPROVED LOCATION EITHER WITHIN THE REAR YARD SETBACK OR 5' MINIMUM FROM THE SIDE P/L--FIELD VERIFY. THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. SPECIAL INSPECTION REPORT REQUIRED AT PRE PLASTER. 2016 CALIFORNIA BUILDING CODE DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 1 0 $2.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $13.42 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $26.83 Total Paid for PLUMBING 2019: $40.25 DESCRIPTION ACCOUNT CITY AMOUNT SWIMMING POOL/SPA 101-0000-42404 0 $201.25 DESCRIPTION ACCOUNT CITY AMOUNT SWIMMING POOL/SPA PC 101-0000-42600 0 $109.48 Total Paid for POOL / SPA 2019: $310.73 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 8495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 AO&L PGA WEST RESIDENTIAL ASSOCIATION, INC. NOTICE TO PROCEED December 23, 2019 Mr. & Mrs. Matthew Smith Page 1 of 2 Re: 54-278 Inverness - Application Dated October 4, 2019 and Received at the Association Office October 4 2019 Review by Architectural Committee October 21 2019 `Review and Comment' Letter October 30 2019 `Review and Comment' Letter #2 November 14 2019 New Contractor November 25 2019 Updated Plan submittal November 262019 Architectural Committee Review December fi 2019, `Review & Comment' Letter #3 December 13, 2019 and Architectural Committee's E-Mail Memo dated December 19, 2019 memorializing the phone conversation regarding the Contractor, JB Pools Construction, naming the two Sub -Contractors and listing all other trades to be performed by JB Pools Construction, insurance coverage for the Ford F350, the personal vehicle of the contractor, Jesse Blancarte, and the E-mail acceptance by Jesse Blancarte dated December 19, 2019. Pool, Spa, Outdoor Shower Raised Fire Pit Gas Line Concrete Hardsca a and Landsra pin Dear Mr. & Mrs. Smith, Your architectural Variance Request submittal is accepted conditional on being in accordance with the Application Submittal Re uirements Architectural Guidelines Association CCU R's and Maintenance and Indemnity A reement. This "Notice to Proceed" authorization is subject to and a part of the Application `Review and Comment' letter dated October 30, 2019, `Review & Comment' letter #2 dated November 14, 2019, `Review & Comment' letter #3 dated December 13, 2019 and memos dated December 19, 2019 (all attached). It is understood that by starting the project, the Homeowner and their Contractor of record commit to their compliance with the Architectural Committee's `Notice to Proceed' letter. It is the responsibility of the homeowner to provide, advise and confirm to their contractor the requirements of this acceptance. This should avoid possible misunderstanding at the project completion. The homeowner and the contractor to schedule a pre -construction meeting with the Landscape/Irrigation Manger, Bill Bobbitt, the Maintenance/Lighting Manager, Fernando Murillo and Architectural Chair Person. Please contact the HOA office to set up the appointments The purpose is to confirm the site pre -construction condition, establishing the responsibility for existing HOA property as documented by photographs. At this meeting pool perimeter to be located and any modifications Page 2 of 2 and repairs to the existin side yard and street side for construction access and the new piping installation to be confirmed. This meeting date commences the period of 45 calendar days for project completion. The timely completion of this ro'ect in the 45 calendar days is essential. It is recommended that the contractor does not schedule a re -construction mcetin with the HOA until they are ready to start the project. The contractor has provided and a reed to the project completion days. The review and approval are based only on the aesthetics of your proposed plan and should not be taken as certification by the HOA. The construction worthiness and integrity of the proposed change is the responsibility of the homeowner and contractor. The HOA does not verify or certify the near property line location. It is the responsibility of the homeowner and contractor to locate any underground utilities and services and modify as needed. The `Notice to Proceed' letter requires a copy of the City of La Quinta Permit to be provided prior to any demolition or construction activity. The contractor to provide a copy of the engineering drawing for the HOA's application file. Please sign in the space provided acknowledging receipt and return a copy for our file to the HOA Managers at the Pre -Construction job walk. Signature Date If I may be of further assistance, please contact me at the HOA office, (760) 771-1234, Extension 15. Cordially, If# I del_ Kelly McGalliard CCAM PCAM Operations Manager For the Architectural Committee Enc. 1 CC: Architectural Committee POOL WATER BOWLS — INFINITY YdALLS 0 516 IL 1 O V O O )NATER BOND - 1 LED LISHT5 F/L TANNING SHELF —9° (I—) b' BW, 11 11 SIC, IT TURF AREA METER 4 �---5'� f �4 — "IRE -PIT 5' x 2 GREY GONGRETE G — 5TU6G0 FINISHED / TURF AREA 7 FIRE PIT 2' +1 +18" RAISED ti b' BYy �1�U CAOQR 5HOYER A RA15ED +16" I�o - EXISTI� GAS I T� NOTES: —REMOVE 5 OUEEN PALMS TO BE REPLACED BY 15 GALLONS QUEEN PALMS. —REMOVE GRA55 AREA AND GAP IRRIGATION. — KEEP EXISTING LANDSCAPE E 57 NC:�) E DE I AGE CITY OF LA C�UH� d� BUILDING & SAFETY DEBT. FOR C®NSTk+. Gl'h-lJN IATF l I j i 1 my 11 i.�10 d® pouts V tal l uIll 11UIiI I:ulmil all•111.1. UR LII: •. L -. 82-365 HWY 111 STE. 101 INDIO CA 92201 760347-4210 OFFICE wwwmpomsmCCOM SMITH RESIDENCE 5427B INVERNESS WY. LA QUINTA, CA 92253 2016 CALIFORNIA BUILDING CODE (BASED ON 20 1 5 IBC) 2016 CALIFORNIA MECHANICAL CODE (BASED ON 201 5 UMC) 201 6 CALIFORNIA PLUMBING CODE (BASED ON 201 4 NEC) 201 6 CALIFORNIA ELECTRICAL CODE (BASED ON 2014 NEC) 2016 CALIFORNIA ENERGY EFFICIENCY STANDARDS INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH SECTION 1 1 4 - MANDATORY REQUIREMENTS. EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL. SECONDARY BOUNDARY TO BE POOL GUARD WATER SENSOR ALARM NSF CERTIFIED TO ASTM F 22❑B—❑B. POOL HEATER, POOL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS. NOTES; 1 . ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED. 2. ALL GFCI OUTLETS SHALL BE WEATHER RESISTANT. 3. ALL OUTLETS SUPPLIED BY SINGLE-PHASE, 1 5A AND 20A, 1 25V OR 240V BRANCH CIRCUIT FOR SWIMMING POOL PUMP MOTORS ARE REQUIRED TO HAVE GFCI PROTECTION . 4. PROVIDE 36" WORKING CLEARANCE FOR THE POOL EQUIPMENT MOTOR IS REQUIRED. I NOTES,