2015 08 25 DHI
I I
Director's Hearing Agendas and staff
f
reports are now available on the
City's web page: www.la-quinta.org
DIRECTOR'S HEARING
AGENDA
CITY HALL STUDY SESSION ROOM
78-495 Calle Tampico, La Quinta
REGULAR MEETING on TUESDAY, AUGUST 25, 2015 AT 3:00 P.M.
PUBLIC HEARINGS
For all Public Hearings on the agenda, a completed "Request to Speak" form must be
filed with the Executive Assistant prior to consideration of that item.
A person may submit written comments to the Director before a public hearing or
appear in support or opposition to the approval of a project(s). If you challenge a
project(s) in court, you may be limited to raising only those issues you or someone
else raised at the public hearing or in written correspondence delivered to the City at,
or prior to the public hearing.
1. Tentative Parcel Map 2015-0006 (TPM 36883), submitted by BR2, LLC.,
proposing to subdivide an approximately 10.94 acre commercial parcel into
four commercial parcels. Project: Washington Park - Phase 4. CEQA: exempt
from further environmental review pursuant to Section 15315 (Class 15 - Minor
Land Divisions). Location: 46800 Washington Street; Parcel 2 of Parcel Map
30903 at the northeast corner of Washington Street and Avenue 47.
2. Tentative Parcel Map 2015-0004 (TPM 36856), submitted by East of Madison,
LLC., proposing to subdivide an approximately 0.97 acre residential parcel into
two residential parcels. Project: The Madison Club. CEQA: exempt from further
environmental review pursuant to Section 15315 (Class 15 - Minor Land
Divisions). Location: 53-650 Fremont Way; Lot 88 of Tract Map 33076-2.
DIRECTOR'S HEARING 1 AUGUST 25, 2015
3. Tentative Parcel Map 2015-0005 (TPM 36855), submitted by East of Madison,
LLC., proposing to subdivide two residential parcels, approximately 0.90 and
0.82 acres, into three residential parcels. Project: The Madison Club. CEQA:
exempt from further environmental review pursuant to Section 15315 (Class 15
- Minor Land Divisions). Location: 53-710 and 53-620 Pike Place, Lots 78 and 79
of Tract Map 33076-2.
ADJOURNMENT
DECLARATION OF POSTING
I, Monika Radeva, Executive Assistant of the City of La Quinta, do hereby declare that
the foregoing Agenda for the Director's Hearing was posted on the outside entry to
the Council Chamber at 78-495 Calle Tampico, and the bulletin boards at 78-630
Highway 111, and the La Quinta Cove Post Office at 51-321 Avenida Bermudas, on
August 20, 2015.
DATED: Au ust 18, 2015
MONIKA RADEVA, Executive Assistant
City of La Quinta, California
PUBLIC NOTICES
The La Quinta City Study Session Room is handicapped accessible. If special equipment is needed for
the hearing impaired, please call the City Clerk's office at 777-7123, twenty-four (24) hours in
advance of the meeting and accommodations will be made.
If special electronic equipment is needed to make presentations to the Director, arrangements
should be made in advance by contacting the City Clerk's office at 777-7123. A one (1) week notice is
required.
If background material is to be presented to the Director during a Director's Hearing, please be
advised that eight (8) copies of all documents, exhibits, etc., must be supplied to the Executive
Assistant for distribution. It is requested that this take place prior to the beginning of the meeting.
Any writings or documents provided to the Director regarding any item(s) on this agenda will be
made available for public inspection at the Community Development Department's counter at City
Hall located at 78-495 Calle Tampico, La Quinta, California, 92253, during normal business hours.
DIRECTOR'S HEARING 2 AUGUST 25, 2015
PH 1
DIRECTOR'S HEARING
STAFF REPORT
DATE: AUGUST 25, 2015
CASE NUMBER: TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
APPLICANT: BILL SANCHEZ FOR BR2, LLC
PROPERTY OWNER: BR2, LLC
REQUEST: SUBDIVIDE EXISTING 10.94 ACRE COMMERCIAL LOT INTO
FOUR COMMERCIAL LOTS
CEQA: EXEMPT FROM FURTHER ENVIRONMENTAL REVIEW
PURSUANT TO SECTION 15315 (CLASS 15 - MINOR LAND
DIVISIONS)
LOCATION: 46800 WASHINGTON STREET; PARCEL 2 OF PARCEL MAP
30903 AT THE NORTHEAST CORNER OF WASHINGTON
STREET AND AVENUE 47
LEGAL: APN: 643-020-032
RECOMMENDED ACTION:
Approve Tentative Parcel Map 2015-0006 (TPM 36883), subject to the attached
Findings and Conditions of Approval.
EXECUTIVE SUMMARY:
The applicant proposes to subdivide an approximately 10.94 acre parcel into four
parcels within the Washington Park commercial development (Attachment 1). Staff
supports the proposal and has no significant issues with the proposed subdivision.
BACKGROUND:
This Washington Park Specific Plan is predominantly developed with various
commercial centers. Phase 4 of the Washington Park Specific Plan is currently being
developed, which includes the construction of a 47,427 square foot, 12-screen movie
theater approved by the Planning Commission under Site Development Permit (SDP)
2014-938 and Conditional Use Permit 2014-158 on August 26, 2014.
PAReports - Dir Hrg\2015\08-25-15 DIR HEARING PACKET\PH 1 - TPM 2015-0006 (TPM 36883) Phase 4 Washington Park into 4 Parcels\PH 1 (1) TMP
2015-0006 (TPM 36883) REPORT - final draft gp.docx
Page 1 of 3
Phase 4 of the Washington Park Specific Plan is located at the northeast corner of
Washington Street and Avenue 47, behind the Lowe's and Target (Attachment 2). The
subject property is a single parcel, which was previously subdivided as part of Parcel
Map 30903. The Specific Plan for this area identifies development of 113,000 square
feet of retail space, including a 64,000 square foot athletic club or commercial retail
space. The site plan for SDP 2014-938 identifies three restaurant pads located along
Washington Street for future development (Attachment 3).
PROPOSAL & ANALYSIS:
Tentative Parcel Map 36883 proposes to subdivide the 10.94 acre property into four
commercial parcels (Attachment 4) as follows:
• Parcel 1
- 7.24 acres
• Parcel 2
- 1.10 acres
• Parcel 3
- 1.23 acres
• Parcel 4
- 1.27 acres
The applicant requests the parcel maps to accommodate separate parcels for the
movie theater and three future commercial pad developments. The proposed division
does not modify any circulation, utility service, density or other design element of the
originally approved Site Development Permit. Reciprocal Parking and circulation
across parcels will ensure a cohesive development.
The design of Tentative Parcel Map 36883, as conditioned, conforms to current state,
regional, and local design guidelines and standards including those of the City of La
Quinta General Plan and Municipal Code. The proposed site design incorporates the
interior circulation pattern, infrastructure, and utilities consistent with that of the
previously approved Site Development Permit, is in compliance with the applicable
Washington Park Specific Plan and General Plan goals, policies, and development
standards.
AGENCY AND PUBLIC REVIEW:
Public Agency Review:
This request was sent to all applicable City departments and affected public agencies
on June 30, 2015. All written comments received are on file and available for review
with the Community Development Department. All applicable comments have been
incorporated in the recommended Conditions of Approval.
Public Notice:
This project was advertised in The Desert Sun newspaper on August 14, 2015, and
mailed to all property owners within 500 feet of the site. To date, no comments have
been received from adjacent property owners. Any written comments received will be
PAReports - Dir Hrg\2015\08-25-15 DIR HEARING PACKET\PH 1 - TPM 2015-0006 (TPM 36883) Phase 4 Washington Park into 4 Parcels\PH 1 (1) TMP
2015-0006 (TPM 36883) REPORT - final draft gp.docx
Page 2 of 3
handed out at the hearing.
ENVIRONMENTAL REVIEW
The City of La Quinta Community Development Department has determined that this
project is Categorically Exempt from the provisions of the California Environmental
Quality Act (CEQA) pursuant to Section 15315 Class 15 (Minor Land Divisions).
Report prepared by: Jay Wuu, Principal Planner
Report approved for submission by: Gabriel Perez, Planning Manager
Attachments: 1. Project Information
2. Project Area Site Map
3. Washington Park- Phase 4 Site Plan (SDP 2014-938)
4. Tentative Parcel Map 36883
5. Site Development Map No. 36883
PAReports - Dir Hrg\2015\08-25-15 DIR HEARING PACKET\PH 1 - TPM 2015-0006 (TPM 36883) Phase 4 Washington Park into 4 Parcels\PH 1 (1) TMP
2015-0006 (TPM 36883) REPORT - final draft gp.docx
Page 3 of 3
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK — PHASE 4
AUGUST 25, 2015
Page 1 of 19
FINDINGS
A. The proposed tentative parcel map is consistent with the city General Plan. The
proposed map conforms to the design guidelines and standards of the General
Plan for Low Density Residential designated properties, as set forth in the Land Use
Element while maintaining residential development standards including setbacks,
pad elevations, and other design and performance standards that assure a high
quality of development. Furthermore, the lots proposed are the similar in size and
configuration of the previously -approved lots prior to their merger and
adjustment.
B. The design or improvement of the proposed tentative parcel map is consistent
with the city General Plan in that its street and parcel design are in conformance
with applicable goals, policies, and development standards, and will provide
adequate infrastructure and public utilities.
C. The design of the tentative parcel map and the proposed improvements are not
likely to cause substantial environmental damage nor substantially injure fish or
wildlife or their habitat. The City of La Quinta Community Development
Department has determined that this project is Categorically Exempt from the
provisions of the California Environmental Quality Act (CEQA) pursuant to Section
15315 Class 15 (Minor Land Divisions).
D. The design of the tentative parcel map and the proposed improvements are not
likely to cause serious public health problems. As conditioned, the proposed
tentative parcel map will not result in any increased hazard to public health or
welfare, as the design has been reviewed by the appropriate responsible agencies
for health and safety issues, with none identified.
E. The site of the proposed tentative parcel map is physically suitable for the type of
development and proposed density of development. As conditioned, the proposed
design of the subdivision is physically compatible with the site with regards to level
topography for the type of land use designation and potential development of the
subject property, and in consideration of existing residential development in the
surrounding area.
F. As conditioned, the proposed tentative parcel map is consistent withal[ applicable
provisions of this title and the La Quinta Zoning Ordinance, including, but not
limited to, minimum lot area requirements, any other applicable provisions of this
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK — PHASE 4
AUGUST 25, 2015
Page 2 of 19
code, and the Subdivision Map Act.
G. As conditioned, the design of the tentative parcel map will not conflict with
easements, acquired by the public at large, for access through or use of property
within the proposed subdivision, for access through or use of the property within
the subdivision in that none presently exist and access is provided within the
project and to adjacent public streets.
CONDITIONS OF APPROVAL
GENERAL
The applicant agrees to defend, indemnify and hold harmless the City of La Quinta
("City"), its agents, officers and employees from any claim, action or proceeding to
attack, set aside, void, or annul the approval of this Tentative Parcel Map, or any
Final Map recorded thereunder. The City shall have sole discretion in selecting its
defense counsel.
The City shall promptly notify the applicant of any claim, action or proceeding and
shall cooperate fully in the defense.
2. Tentative Parcel Map 36883 shall comply with all applicable conditions and/or
mitigation measures for the following related approval(s):
Site Development Permit 2014-938, Tentative Parcel Map 30903, Conditional Use
Permit 2014-158, MOA 2014-0013.
3. This Tentative Parcel Map, and any Final Map recorded thereunder, shall comply
with the requirements and standards of Government Code §§ 66410 through
66499.58 (the "Subdivision Map Act"), and Chapter 13 of the La Quinta Municipal
Code ("LQMC").
The City of La Quinta's Municipal Code can be accessed on the City's Web Site at
www.lo-quinto.org.
4. This Tentative Parcel Map shall expire on August 25, 2016, two years from the date
of Director's Hearing approval, unless recorded or granted a time extension
pursuant to the requirements of La Quinta Municipal Code 13.12.160 (Extensions
of time for tentative maps).
FINDINGS AND CONDITIONS OF APPROVAL - RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK - PHASE 4
AUGUST 25, 2015
Page 3 of 19
5. Prior to the issuance of any grading, construction, or building permit by the City,
the applicant shall obtain any necessary clearances and/or permits from the
following agencies, if required:
• Riverside County Fire Marshal
• La Quinta Public Works Department (Grading Permit, Green Sheet (Public
Works Clearance) for Building Permits, Water Quality Management
Plan(WQMP) Exemption Form - Whitewater River Region, Improvement
Permit)
• La Quinta Community Development Department
• Riverside Co. Environmental Health Department
• Desert Sands Unified School District (DSUSD)
• Coachella Valley Water District (CVWD)
• Imperial Irrigation District (IID)
• California Regional Water Quality Control Board (CRWQCB)
• State Water Resources Control Board
• SunLine Transit Agency (SunLine)
• South Coast Air Quality Management District Coachella Valley (SCAQMD)
The applicant is responsible for all requirements of the permits and/or clearances
from the above listed agencies. When these requirements include approval of
improvement plans, the applicant shall furnish proof of such approvals when
submitting those improvement plans for City approval.
6. The applicant shall comply with applicable provisions of the City's NPDES
stormwater discharge permit, LQMC Sections 8.70.010 et seq. (Stormwater
Management and Discharge Controls), and 13.24.170 (Clean Air/Clean Water);
Riverside County Ordinance No. 457; the California Regional Water Quality Control
Board - Colorado River Basin Region Board Order No. R7-2013-0011 and the State
Water Resources Control Board's Order No. 2009-0009-DWQ and Order No. 2010-
0014-DWQ.
A. For construction activities including clearing, grading or excavation of land
that disturbs one (1) acre or more of land, or that disturbs less than one (1)
acre of land, but which is a part of a construction project that encompasses
more than one (1) acre of land, the Permitee shall be required to submit a
Storm Water Pollution Protection Plan ("SWPPP") to the State Water
Resources Control Board.
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK — PHASE 4
AUGUST 25, 2015
Page 4 of 19
The applicant or design professional can obtain the California Stormwater
Quality Association SWPPP template at www.cabmphandbooks.com for use
in their SWPPP preparation.
B. The applicant shall ensure that the required SWPPP is available for
inspection at the project site at all times through and including acceptance
of all improvements by the City.
C. The applicant's SWPPP shall include provisions for all of the following Best
Management Practices ("BMPs") (LQMC Section 8.70.020 (Definitions)):
1) Temporary Soil Stabilization (erosion control).
2) Temporary Sediment Control.
3) Wind Erosion Control.
4) Tracking Control.
5) Non -Storm Water Management.
6) Waste Management and Materials Pollution Control.
D. All erosion and sediment control BMPs proposed by the applicant shall be
approved by the City Engineer prior to any onsite or offsite grading,
pursuant to this project.
E. The SWPPP and BMPs shall remain in effect for the entire duration of project
construction until all improvements are completed and accepted by the
City Council.
F. The applicant shall execute and record an agreement that provides for the
perpetual maintenance and operation of all post -construction BMPs as
required.
7. Permits issued under this approval shall be subject to the provisions of the
Development Impact Fee and Transportation Uniform Mitigation Fee programs in
effect at the time of issuance of building permit(s).
8. Approval of this Tentative Parcel Map shall not be construed as approval for any
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK — PHASE 4
AUGUST 25, 2015
Page 5 of 19
horizontal dimensions implied by any site plans or exhibits unless specifically
identified in the following conditions of approval.
9. Developer shall reimburse the City, within thirty (30) days of presentment of the
invoice, all costs and actual attorney's fees incurred by the City Attorney to review,
negotiate and/or modify any documents or instruments required by these
conditions, if Developer requests that the City modify or revise any documents or
instruments prepared initially by the City to effect these conditions. This obligation
shall be paid in the time noted above without deduction or offset and Developer's
failure to make such payment shall be a material breach of the Conditions of
Approval.
10. Developer shall reimburse the City, within thirty (30) days of presentment of the
invoice, all costs and actual consultant's fees incurred by the City for engineering
and/or surveying consultants to review and/or modify any documents or
instruments required by this project. This obligation shall be paid in the time noted
above without deduction or offset and Developer's failure to make such payment
shall be a material breach of the Conditions of Approval.
PROPERTY RIGHTS
11. Prior to issuance of any permit(s), the applicant shall acquire or confer
easements and other property rights necessary for the construction or proper
functioning of the proposed development. Conferred rights shall include
irrevocable offers to dedicate or grant access easements to the City for
emergency services and for maintenance, construction and reconstruction of
essential improvements. Said conferred rights shall also include grant of access
easement to the City of La Quinta for the purpose of graffiti removal by City
staff or assigned agent in perpetuity and agreement to the method to remove
graffiti and to paint over to best match existing. The applicant shall establish the
aforementioned requirements in the right of way documents for the
development or other agreements as approved by the City Engineer. Pursuant to
the aforementioned, the applicant shall submit and execute an
"AUTHORIZATION TO REMOVE GRAFFITI FROM PRIVATE PROPERTY" form
located at the Public Works Department Counter prior to Certificate of
Occupancy of future development.
12. Pursuant to the aforementioned condition, conferred rights shall include
approvals from the master developer over easements and other property rights
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK — PHASE 4
AUGUST 25, 2015
Page 6 of 19
necessary for construction and proper functioning of the proposed development
not limited to access rights over proposed and/or existing parking, access aisles
that access public streets and open space/drainage facilities of the development.
Said rights shall also include reciprocal access and reciprocal parking rights
within Tentative Parcel Map 36883 and easements for utility lines to the
satisfaction of the City Engineer.
13. Where public facilities are placed on privately -owned setbacks, the applicant
shall offer for dedication blanket easements for those purposes on the Final
Map.
14. The applicant shall offer for dedication those easements necessary for the
placement of, and access to, utility lines and structures, drainage basins,
mailbox clusters, park lands, and common areas on the Final Map.
15. Direct vehicular access to Washington Street and Avenue 47 is restricted,
except for those access points identified on the tentative parcel map, or as
otherwise conditioned in these conditions of approval. The vehicular access
restriction shall be shown on the recorded final parcel map.
16. The applicant shall furnish proof of easements, or written permission, as
appropriate, from those owners of all abutting properties on which grading,
retaining wall construction, permanent slopes, or other encroachments will occur.
17. The applicant shall cause no easement to be granted, or recorded, over any
portion of the subject property between the date of approval of the Tentative
Parcel Map and the date of recording of any Final Map, unless such easement is
approved by the City Engineer.
MAPrI
18. Prior to the City's approval of a Final Map, the applicant shall furnish accurate
mylars of the Final Map. The Final Map shall be 1" = 40' scale.
19. Identify Flood Zone X instead of Flood Zone C for project note #3 on Tentstive Tract
Map No. 36883.
IMPROVEMENT PLANS
FINDINGS AND CONDITIONS OF APPROVAL - RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK - PHASE 4
AUGUST 25, 2015
Page 7 of 19
As used throughout these Conditions of Approval, professional titles such as "engineer,"
"surveyor," and "architect," refer to persons currently certified or licensed to practice their
respective professions in the State of California.
20. Improvement plans shall be prepared by or under the direct supervision of
qualified engineers and/or architects, as appropriate, and shall comply with the
provisions of LQMC Section 13.24.040 (Improvement Plans).
21. The following improvement plans shall be prepared and submitted for review and
approval by the Public Works Department. A separate set of plans for each line
item specified below shall be prepared. The plans shall utilize the minimum scale
specified, unless otherwise authorized by the City Engineer in writing. Plans may
be prepared at a larger scale if additional detail or plan clarity is desired. Note, the
applicant may be required to prepare other improvement plans not listed here
pursuant to improvements required by other agencies and utility purveyors.
A. On -Site Precise Grading Plan 1" = 30' Horizontal
B. PM10 Plan
1" = 40' Horizontal
C. WQMP (Plan submitted in Report Form)
D. On -Site Private Water and Sewer Plans 1" = 20' Horizontal
(Separate Storm Drain Plans if applicable)
Other engineered improvement plans prepared for City approval that are not listed
above shall be prepared in formats approved by the City Engineer prior to
commencing plan preparation.
All Off -Site Plan & Profile Street Plans and Signing & Striping Plans shall show all
existing improvements for a distance of at least 200-feet beyond the project limits,
or a distance sufficient to show any required design transitions.
All On -Site Signing & Striping Plans shall show, at a minimum; Stop Signs, Limit
Lines and Legends, No Parking Signs, Raised Pavement Markers (including Blue
RPMs at fire hydrants) and Street Name Signs per Public Works Standard Plans
and/or as approved by the Engineering Department.
FINDINGS AND CONDITIONS OF APPROVAL - RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK - PHASE 4
AUGUST 25, 2015
Page 8 of 19
The applicant shall prepare an accessibility assessment on a marked up print of
the building floor plan identifying every building egress and notes the 2010
California Building Code accessibility requirements associated with each door. The
assessment must comply with submittal requirements of the Building & Safety
Department. A copy of the reviewed assessment shall be submitted to the Public
Works Department in conjunction with the Site Development Plan when it is
submitted for plan checking.
In addition to the normal set of improvement plans, a "Precise Grading" plan is
required to be submitted for approval by the Building Official, Community
Development Director and the City Engineer.
"Precise Grading" plans shall normally include all on -site surface improvements
including but not limited to finish grades for curbs & gutters, building floor
elevations, wall elevations, parking lot improvements and ADA requirements.
22. The City maintains standard plans, detail sheets and/or construction notes for
elements of construction which can be accessed via the "Plans, Notes and Design
Guidance" section of the Public Works Department at the City website (www.la-
quinta.org). Please navigate to the Public Works Department home page and look
for the Standard Drawings hyperlink.
23. The applicant shall furnish a complete set of all approved improvement plans on a
storage media acceptable to the City Engineer (currently mylars).
24. Upon completion of construction, and prior to final acceptance of the
improvements by the City, the applicant shall furnish the City with reproducible
record drawings of all improvement plans which were approved by the City. Each
sheet shall be clearly marked "Record Drawing" and shall be stamped and signed
by the engineer or surveyor certifying to the accuracy and completeness of the
drawings. The applicant shall have all approved mylars previously submitted to
the City, revised to reflect the as -built conditions. The applicant shall employ or
retain the Engineer of Record during the construction phase of the project so that
the FOR can make site visits in support of preparing "Record Drawing". However, if
subsequent approved revisions have been approved by the City Engineer and
reflect said "Record Drawing" conditions, the Engineer of Record may submit a
letter attesting to said fact to the City Engineer in lieu of mylar submittal.
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK — PHASE 4
AUGUST 25, 2015
Page 9 of 19
IMPROVEMENT SECURITY AGREEMENTS
32. Prior to approval of any Final Map, the applicant shall construct all on and off -
site improvements and satisfy its obligations for same, or shall furnish a fully
secured and executed Subdivision Improvement Agreement ("SIA") guaranteeing
the construction of such improvements and the satisfaction of its obligations for
same, or shall agree to any combination thereof, as may be required by the City.
33. Any Subdivision Improvement Agreement ("SIA") entered into by and between
the applicant and the City of La Quinta, for the purpose of guaranteeing the
completion of any improvements related to this Tentative Tract Map, shall
comply with the provisions of LQMC Chapter 13.28 (Improvement Security).
34. Improvements to be made, or agreed to be made, shall include the removal of
any existing structures or other obstructions which are not a part of the
proposed improvements; and shall provide for the setting of the final survey
monumentation.
35. Depending on the timing of the development of this Tentative Tract Map, and
the status of the off -site improvements at the time, the applicant may be
required to:
A. Construct certain off -site improvements.
B. Construct additional off -site improvements, subject to the reimbursement
of its costs by others.
C. Reimburse others for those improvements previously constructed that are
considered to be an obligation of this tentative tract map.
D. Secure the costs for future improvements that are to be made by others.
E. To agree to any combination of these actions, as the City may require.
Off -Site Improvements should be completed on a first priority basis.
In the event that any of the improvements required for this development are
constructed by the City, the applicant shall, prior to the approval of the Final
Map, or the issuance of any permit related thereto, reimburse the City for the
costs of such improvements.
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK — PHASE 4
AUGUST 25, 2015
Page 10 of 19
36. If the applicant elects to utilize the secured agreement alternative, the applicant
shall submit detailed construction cost estimates for all proposed on -site and
off -site improvements, including an estimate for the final survey
monumentation, for checking and approval by the City Engineer. Such
estimates shall conform to the unit cost schedule as approved by the City
Engineer.
At the time the applicant submits its detailed construction cost estimates for
conditional approval of the Final Map by the City Council, the applicant shall
also submit one copy each of an 8-1 /2" x 11 " reduction of each page of the
Final Map, along with a copy of an 8-1 /2" x 11 " Vicinity Map.
Estimates for improvements under the jurisdiction of other agencies shall be
approved by those agencies and submitted to the City along with the applicant's
detailed cost estimates.
Security will not be required for telephone, natural gas, or Cable T.V.
improvements.
37. Should the applicant fail to construct the improvements for the development, or
fail to satisfy its obligations for the development in a timely manner, the City
shall have the right to halt issuance of building permits, and/or final building
inspections, withhold other approvals related to the development of the project,
or call upon the surety to complete the improvements.
GRADING
25. The applicant shall comply with the provisions of LQMC Section 13.24.050 (Grading
Improvements).
26. Prior to occupancy of the project site for any construction, or other purposes, the
applicant shall obtain a grading permit approved by the City Engineer.
27. To obtain an approved grading permit, the applicant shall submit and obtain
approval of all of the following:
A. A grading plan prepared by a civil engineer registered in the State of
California,
B. A preliminary geotechnical ("soils") report prepared by a professional
FINDINGS AND CONDITIONS OF APPROVAL - RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK - PHASE 4
AUGUST 25, 2015
Page 11 of 19
registered in the State of California,
C. A Fugitive Dust Control Plan prepared in accordance with LQMC Chapter
6.16, (Fugitive Dust Control), and
D. A Best Management Practices report prepared in accordance with LQMC
Sections 8.70.010 and 13.24.170 (NPDES Stormwater Discharge Permit and
Storm Management and Discharge Controls).
E. A WQMP prepared by an authorized professional registered in the State of
California.
All grading shall conform with the recommendations contained in the Preliminary
Soils Report, and shall be certified as being adequate by soils engineer, or
engineering geologist registered in the State of California.
A statement shall appear on the Final Map that a soils report has been prepared in
accordance with the California Health & Safety Code § 17953.
The applicant shall furnish security, in a form acceptable to the City, and in an
amount sufficient to guarantee compliance with the approved Fugitive Dust
Control Plan provisions as submitted with its application for a grading permit.
Additionally, the applicant shall replenish said security if expended by the City of
La Quinta to comply with the Plan as required by the City Engineer.
28. The applicant shall maintain all open graded, undeveloped land in order to prevent
wind and/or water erosion of such land. All open graded, undeveloped land shall
either be planted with interim landscaping, or stabilized with such other erosion
control measures, as were approved in the Fugitive Dust Control Plan.
29. Building pad elevations on the rough grading plan submitted for City Engineer's
approval shall conform with pad elevations shown on the tentative map, unless
the pad elevations have other requirements imposed elsewhere in these
Conditions of Approval.
30. Building pad elevations of perimeter lots shall not differ by more that one foot
higher from the building pads in adjacent developments.
31. Prior to any site grading or regrading that will raise or lower any portion of the site
by more than plus or minus five tenths of a foot (0.5') from the elevations shown
FINDINGS AND CONDITIONS OF APPROVAL - RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK - PHASE 4
AUGUST 25, 2015
Page 12 of 19
on the approved Tentative Parcel Map, the applicant shall submit the proposed
grading changes to the City Staff for a substantial conformance finding review.
32. Prior to the issuance of a building permit for any building lot, the applicant shall
provide a lot pad certification stamped and signed by a qualified engineer or
surveyor with applicable compaction tests and over excavation documentation.
Each pad certification shall list the pad elevation as shown on the approved
grading plan, the actual pad elevation and the difference between the two, if any.
Such pad certification shall also list the relative compaction of the pad soil. The
data shall be organized by lot number, and listed cumulatively if submitted at
different times.
33. Prior to any grading improvements, the applicant shall submit grading
performance security valued at 100% of the cost of the grading improvements in
accordance with La Quinta Municipal Code 8.80.050, or as approved by the City
Engineer.
In the event the applicant fails to construct the improvements for the
development, or fails to satisfy its obligations for the development in a timely
manner, pursuant to the approved plan, the City shall have the right to halt
issuance of all permits, and/or final inspections, withhold other approvals related
to the development of the project, or call upon the surety to complete the
improvements.
DRAINAGE
34. Stormwater handling shall conform with the approved hydrology and drainage
report for SDP 2014-938 and/or Parcel Map 30903, or as approved by the City
Engineer. Nuisance water shall be disposed of in an approved manner.
35. The design of the development shall not cause any increase in flood boundaries
and levels in any area outside the development.
36. The applicant shall comply with the provisions of LQMC Section 13.24.120
(Drainage), Retention Basin Design Criteria, Engineering Bulletin No. 06-16 -
Hydrology Report with Preliminary Hydraulic Report Criteria for Storm Drain
Systems and Engineering Bulletin No. 06-015 - Underground Retention Basin
Design Requirements. More specifically, stormwater falling on site during the 100
year storm shall be retained within the development, unless otherwise approved
FINDINGS AND CONDITIONS OF APPROVAL - RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK - PHASE 4
AUGUST 25, 2015
Page 13 of 19
by the City Engineer. The tributary drainage area shall extend to the centerline of
adjacent public streets. The design storm shall be either the 1 hour, 3 hour, 6 hour
or 24 hour event producing the greatest total run off.
37. Nuisance water shall be retained on site. Nuisance water shall be disposed of per
approved methods contained in Engineering Bulletin No. 06-16 - Hydrology Report
with Preliminary Hydraulic Report Criteria for Storm Drain Systems and Engineering
Bulletin No. 06-015 - Underground Retention Basin Design Requirements.
38. In design of retention facilities, the maximum percolation rate shall be two inches
per hour. The percolation rate will be considered to be zero unless the applicant
provides site specific data indicating otherwise and as approved by the City
Engineer.
39. The project shall be designed to accommodate purging and blowoff water
(through underground piping and/or retention facilities) from any on -site or
adjacent well sites granted or dedicated to the local water utility authority as a
requirement for development of this property.
40. No fence or wall shall be constructed around any retention basin unless approved
by the Community Development Director and the City Engineer.
41. For on -site above ground common retention basins, retention depth shall be
according to Engineering Bulletin No. 06-16 - Hydrology Report with Preliminary
Hydraulic Report Criteria for Storm Drain Systems. Side slopes shall not exceed 3:1
and shall be planted with maintenance free ground cover. Additionally, retention
basin widths shall be not less than 20 feet at the bottom of the basin.
42. Stormwater may not be retained in landscaped parkways or landscaped setback
lots. Only incidental storm water (precipitation which directly falls onto the
setback) will be permitted to be retained in the landscape setback areas. The
perimeter setback and parkway areas in the street right-of-way shall be shaped
with berms and mounds, pursuant to LQMC Section 9.100.040(B)(7).
43. The design of the development shall not cause any increase in flood boundaries
and levels in any area outside the development.
44. The development shall be graded to permit storm flow in excess of retention
capacity to flow out of the development through a designated overflow and into
the historic drainage relief route.
FINDINGS AND CONDITIONS OF APPROVAL - RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK - PHASE 4
AUGUST 25, 2015
Page 14 of 19
45. Storm drainage historically received from adjoining property shall be received and
retained or passed through into the historic downstream drainage relief route.
46. The applicant shall comply with applicable provisions for post construction runoff
per the City's NPDES stormwater discharge permit, LQMC Sections 8.70.010 et seq.
(Stormwater Management and Discharge Controls), and 13.24.170 (Clean
Air/Clean Water); Riverside County Ordinance No. 457; and the California Regional
Water Quality Control Board - Colorado River Basin (CRWQCB-CRB) Region Board
Order No. R7-2013-0011 and the State Water Resources Control Board's Order No.
2009-0009-DWQ and Order No. 2010-0014-DWQ or the most current order that is
in effect.
A. For post -construction urban runoff from New Development and
Redevelopments Projects, the applicant shall implement requirements of
the NPDES permit for the design, construction and perpetual operation and
maintenance of BMPs per the approved Water Quality Management Plan
(WQMP) for the project as required by the California Regional Water Quality
Control Board - Colorado River Basin (CRWQCB-CRB) Region Board Order No.
R7-2013-0011.
B. The applicant shall implement the WQMP Design Standards per (CRWQCB-
CRB) Region Board Order No. R7-2013-0011 utilizing BMPs approved by the
City Engineer. A project specific WQMP shall be provided which incorporates
Site Design and Treatment BMPs utilizing first flush infiltration as a
preferred method of NPDES Permit Compliance for Whitewater River
receiving water, as applicable.
C. The developer shall execute and record a Stormwater Management/BMP
Facilities Agreement that provides for the perpetual maintenance and
operation of stormwater BMPs.
111113111:0
47. The applicant shall comply with the provisions of LQMC Section 13.24.110
(Utilities).
48. The applicant shall obtain the approval of the City Engineer for the location of all
utility lines within any right-of-way, and all above -ground utility structures
including, but not limited to, traffic signal cabinets, electric vaults, water valves,
and telephone stands, to ensure optimum placement for practical and aesthetic
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK — PHASE 4
AUGUST 25, 2015
Page 15 of 19
purposes.
49. Underground utilities shall be installed prior to overlying hardscape. For
installation of utilities in existing improved streets, the applicant shall comply
with trench restoration requirements maintained, or required by the City
Engineer.
IMPERIAL IRRIGATION DISTRICT
50. Based on preliminary information provided it is anticipated that the additional
power load requirement of the proposed project would potentially necessitate the
design and construction of a primary distribution feeder backbone extension
(conduit installation and cable). This work would be at the expense of the
applicant. Any related easements and rights -of -way must be provided by
applicant.
51. Power line extensions to serve this development will be made in accordance with
IID Regulation No.15 and Regulation No. 2. The final cost will be determined once
the applicant submits a customer service proposal application and final design is
completed.
52. Applicant should contact IID Energy La Quinta Division Customer Operations, 81-
600 Avenue 58 LA Quinta, CA 92253, telephone no. (760)398-5890 or (760)398-
5841, for information regarding electrical service for the project and any additional
IID Electrical infrastructure that may be needed to service this project.
53. Any construction or operation on IID property or within its existing and proposed
right of way or easements including but not limited to: surface improvements such
as proposed new streets, driveways, parking lots, landscape; and all water, sewer,
storm water, or any other above ground or underground utilities; will require an
encroachment permit, or encroachment agreement (depending on the
circumstances). A copy of the IID encroachment permit application and
instructions for its completion can be found at the IID website. The IID Real estate
Section should be contacted at (760)339-9239 for additional information
regarding encroachment permits and agreements.
54. Any new, relocated, modified or reconstructed IID facilities required for and by the
project (which can include but is not limited to electrical utility substation,
electrical transmission and distribution lines, etc.) need to be included as part of
the project's CEQA and/or NEPA documentation, environmental impact analysis
FINDINGS AND CONDITIONS OF APPROVAL - RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK - PHASE 4
AUGUST 25, 2015
Page 16 of 19
and mitigation. Failure to do so will result in postponement of any construction
and/or modification of IID facilities until such time as the environmental
documentation is amended and environmental impacts are fully mitigated. Any
and all mitigation necessary as a result of the construction, relocation and/or
upgrade of IID facilities is the responsibility of the project proponent.
MAINTENANCE
55. The applicant shall comply with the provisions of LQMC Section 13.24.160
(Maintenance).
56. The applicant shall make provisions for the continuous and perpetual
maintenance of on -site landscaping, access drives, sidewalks, and stormwater
BMPs.
FEES AND DEPOSITS
57. The applicant shall comply with the provisions of LQMC Section 13.24.180 (Fees
and Deposits). These fees include all deposits and fees required by the City for
plan checking and construction inspection. Deposits and fee amounts shall be
those in effect when the applicant makes application for plan check and permits.
FIRE DEPARTMENT
58. The required fire flow shall be available from 5 Super hydrant(s) (6" x 4" x 21/2" x
21/2") spaced not more than 300 apart and shall be capable of delivering a fire
flow 5,500 GPM per minute for four hours duration at 20 psi residual operating
pressure, which must be available before any combustible material is placed on
the construction site.
59. Prior to building plan approval and construction, applicant/developer shall furnish
two copies of the water system fire hydrant plans to Fire Department for review
and approval. Plans shall be signed by a registered civil engineer, and shall confirm
hydrant type, location, spacing, and minimum fire flow. Once plans are signed and
approved by the local water authority, the originals shall be presented to the Fire
Department for review and approval.
60. Prior to issuance of building permits, the water system for fire protection must be
provided as approved by the Fire Department and the local water authority.
FINDINGS AND CONDITIONS OF APPROVAL - RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK - PHASE 4
AUGUST 25, 2015
Page 17 of 19
61. Blue dot retro-reflectors pavement markers on private streets, public streets and
driveways to indicated location of the fire hydrant. 06-05 (located at
www.rvcfire.org)
62. Fire Apparatus access road shall be in compliance with the Riverside County Fire
Department Standard number 06-05 (located at www.rvcfire.org). Access lanes
will not have an up, or downgrade of more than 15%. Access roads shall have an
unobstructed vertical clearance not less than 13 feet and 6 inches. Access lanes
will be designed to withstand the weight of 75 thousand pounds over 2 axles.
Access will have a turning radius capable of accommodating fire apparatus.
Access lane shall be constructed with a surface so as to provide all weather driving
capabilities.
63. An approved Fire Department access key lock box (Minimum Knox Box 3200 series
model) shall be installed next to the approved Fire Department access door to the
building. If the buildings are protected with an alarm system, the lock box shall be
required to have tampered monitoring. Required order forms and installation
standards may be obtained at the Fire Department.
64. Display street numbers in a prominent location on the address side of building(s)
and/or rear access if applicable. Numbers and letters shall be a minimum of 12" in
height for building(s) up to 25' in height. In complexes with alpha designations,
letter size must match numbers. All addressing must be legible, of a contrasting
color, and adequately illuminated to be visible from street at all hours.
65. Install a complete commercial fire sprinkler system. Fire sprinkler system(s) with
pipe sizes in excess of 4" in diameter will require the project Structural Engineer to
certify with a "wet signature", that the structural system is designed to support
the seismic and gravity loads to support the additional weight of the sprinkler
system. All fire sprinkler risers shall be protected from any physical damage.
66. The PIV and FCD shall be located to the front of building within 50 feet of approved
roadway and within 200 feet of an approved hydrant. Sprinkler riser room must
have indicating exterior and/or interior door signs. A C-16 licensed contactor must
submit plans, along with current permit fees, to the Fire Department for review
and approval prior to installation
67. Install an alarm monitoring system for fire sprinkler system(s) with 20 or more
heads, along with current permit fees, to the Fire Department for review and
approval prior to installation.
FINDINGS AND CONDITIONS OF APPROVAL - RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK - PHASE 4
AUGUST 25, 2015
Page 18 of 19
68. Install a portable fire extinguisher, with a minimum rating of 2A-10BC, for every
3,000 sq. ft. and/or 75 feet of travel distance. Fire extinguishers shall be mounted
3.5 to 5 ft above finished floor, measured to the top of the extinguisher. Where
not readily visible, signs shall be posted above all extinguishers to indicate their
locations. Extinguishers must have current CSFM service tags affixed.
69. No hazardous materials shall be stored and/or used within the building, which
exceeds quantities listed in 2013 CBC. No class I, II or IIIA of
combustible/flammable liquid shall be used in any amount in the building.
70. Exit designs, exit signs, door hardware, exit markers, exit doors, and exit path
marking shall be installed per the 2013 California Building Code.
71. Electrical room doors, if applicable, shall be posted "ELECTRICAL ROOM" on outside
of door.
72. Fire Alarm Control Panel room doors, if applicable, shall be posted "FACP" on
outside of door.
73. Fire Riser Sprinkler room doors, if applicable, shall be posted "Fire Riser" on outside
of door.
74. Roof Access room door, if applicable, shall be posted "Roof Access" on outside of
door.
75. Access shall be provided to all mechanical equipment located on the roof as
required by the Mechanical Code.
76. Driveway loops, fire apparatus access lanes and entrance curb radius should be
designed to adequately allow access of emergency fire vehicles. The applicant or
developer shall include in the building plans the required fire lanes and include the
appropriate lane printing and/or signs
77. Air handling systems supplying air in excess of 2000 cubic feet per minute to
enclosed spaces within buildings shall be equipped with an automatic shutoff.
2013 CMC
78. Nothing in our review shall be construed as encompassing structural integrity.
Review of this plan does not authorize or approve any omission or deviation from
all applicable regulations. Final approval is subject to plan review and field
FINDINGS AND CONDITIONS OF APPROVAL - RECOMMENDED
TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
WASHINGTON PARK - PHASE 4
AUGUST 25, 2015
Page 19 of 19
inspection. All questions regarding the meaning of the code requirements should
be referred to Fire Department at 760-863-8886.
79. The minimum dimension for gates is 20 feet clear and unobstructed width and a
minimum vertical clearance of 13 feet 6 inches in height. Any gate providing
access from a road shall be located at least 35 feet setback from the roadway and
shall open to allow a vehicle to stop without obstructing traffic on the road.
Where a one-way road with a single traffic lane provides access to a gate
entrance, a 38-foot turning radius shall be used.
80. Gate(s) shall be automatic or manual operated. Install Knox key operated
switches, with dust cover, mounted per recommended standard of the Knox
Company. Building plans shall include mounting location/position and operating
standards for Fire Department approval.
81. Any portion of the facility or of an exterior wall of the first story of the building
shall not be located more than 150 feet from fire apparatus access roads as
measured by an approved route around the complex, exterior of the facility or
building.
ATTACHMENT 1
Project Information
CASE NUMBER: TENTATIVE PARCEL MAP 2015-0006 (TPM 36883)
APPLICANT: BILL SANCHEZ FOR BR2, LLC
PROPERTY OWNER: BR2, LLC
ENGINEER: ADKAN ENGINEERS
REQUEST: SUBDIVIDE EXISTING 10.94 ACRE COMMERCIAL LOT IN
PHASE 4 OF THE WASHINGTON PARK COMMERCIAL CENTER
INTO FOUR COMMERCIA LOTS
LOCATION: 46-800 WASHINGTON STREET
GENERAL PLAN
DESIGNATION: GENERAL COMMERCIAL
ZONING
DESIGNATION: REGIONAL COMMERCIAL
SPECIFIC PLAN: WASHINGTON PARK (SP 1987-011 AMENDMENT 4)
SURROUNDING
ZONING/LAND USES:
NORTH:
REGIONAL COMMERCIAL
EXISTING COMMERCIAL DEVELOPMENT
SOUTH:
COMMUNITY COMMERCIAL
EXISTING COMMERCIAL DEVELOPMENT
EAST:
REGIONAL COMMERCIAL
VACANT, UN -ENTITLED LAND
WEST:
LOW DENSITY RESIDENTIAL
EXISTING RESIDENTIAL DEVELOPMENT
Xz'
•
Ov* rti
•
r/1
Res
d,Al
4
ILL
769
T,
P.1w , i Wd
ji
ko.";
L�, SAND FLOVIIER �.L.k:�` � ���,,, �, _: �,, � -
tilt
UJ
F J
Cn
Am
CREST 'V'IE
TERM
N"
71 plr;61�1
Al.
Ak
I
t
4b
V
Oh Jr
4
Iy
, .
r°
.�
OF.
�
HIGHLAND11/A.NM
7-1
.r t AM
•
bk
1,3
r 4
zn%&
WE '
S
r"r
Ax,
Is,.
3r.
Washington Park
Phase 4
Project Area Site Map
ATTACHMENT 2
2
C)
M
w E
S
August 13, 2014
LOJ ,. City of La Quinta
T
Planning Division
_ o��imw�of Community Development Department
REGIONAL COMMERCIAL
� s s
CO,MME
PROPOSED THEATER
42,427 st
�Q
ti
-C
Et
'QF
KEY PLAN TQ� BE
YaD
�� fi.669 S F
Future Pad Buildings to
be Processed with
Seperate SDP.
fio 90 21 1
�4 �
ATTACHMENT 3
m
Z
W
AS-1
WASHINGTON PARK - PHASE 4 BoV,"` °P.A°'� ` ° ''Group
j�
30240 Rancho lha ,CA 12675 .o�unMvav�e�uoxc°wm cu6ir.�oi �..rvo Ind. 5tn Fio°r DLR GI O V p
San Juan Capishano,CA 92675 ..ra oqe ��ivae iMPPi®erwenacxnm- OSbzb°79ct s�ias
LA QUINTA, CA 1: 949.443.1234 f 626 ]96 8735
AUGUST 6, 2014 75-13715-00
eTTar'WKA=IVT d
EASEMENT NOTES
® AN EASEMENT OR OTHER PROVISIONS FOR THE FURP05E OF A6GE55 AND
R16HT5 INCIDENTAL THERETO AS 5HONN ON THE RECORDED MAP, NNICH AFFEC T5
PARCELS A, B, C, D.
® THE MATTERS CONTAINED IN AN INSTRUMENT ENTITLED RECIPROCAL AGGE55 AND
WATER L INE EASEMENT, BY AND BETWEEN WA50N5TON Ill, LTD. AND LOWE5 HIW,
f I
INC., UPON THE TERMS THEREIN PROVIDED RECORDED AU5U5T 6, 2005 AS
IN5TRU4NT NO. 03-5g6402 OF OFFICIAL RE60RO5.
AFFECTS PARCELS A, DO
r
�I 1
® THE MATTERS CONTAINED IN AN INSTRUMENT ENTITLED RECIPROCAL ACCESS
I
EASEMENT, BY AND BEHEEN WA5HIN6T0N Ill, LTD. AND LONE5 HIW, INC., AND
TARGET CORPORATION, UPON THE TERM5 THEREIN PROVIDED RECORDED Al.i5t/5T
6, 2003 AS 1N57RUMENT NO. 03 5g6401 OF OFFICIAL RECOR05.
AFFECTS PARCELS A, B, D
® AN EASEMENT FOR UNDERGROUND PIPELINE AND Rl6HT5 INCIDENTAL THERETO IN
FAVOR OF COACHELLA VALLEYWATER DISTRICT AS SET FORTH IN A Do'UMENT
RECORDED NOVEMBER 17, 2006 A5 IN5TRUMENT NO, 06-652566 OF OFFICIAL
RE6ORO5, AFFECTS A5 5HOWN THEREIN.
�g HALFr WIDTH
! 39' 12'
WASHIN6TON STREET
EXI5 T I N6 I MPRO VEMEN T5
72'
36' 36'
1224' 1 24' 12'
AVENUE 47
EXI S TI M6 I MPROVEMENT5
26' 26'
6' 211' 20' 6'
LA QUINTA CENTER ORIVE
EX I S T I M6 IMPROVEMENTS
SITE
IN THE cir e F.++ LA 11 COUNTY OF RIVERSIDE, STATE OF GALIPORN/A
TDEYELOFMENT MAF NO. 36883
BE/N&
A PORTION OF THE NORTHEAST QUARTER OF 5ECTION W, TONNSHIP 5 501)7H, RANGE 7 EAST
BASED ON THE 5AN BERNI+RDINO MERip1AN
� � �� } �
�� ✓� � ��
k f
fl III IIy..'I� I I I I W 'i4fl !I I
:1✓' ! !
�
�ifh 'ri
�
�
i1 I I I I I III
i' �
•�. f r
rs�
'
el �. 1 J �\I �l ✓ ��r :J
J-01
��
j`
} }}
�
y2.a ARi
i W
1
I
I f
I 6
k � 1 k
�I 1
PROJECT NOTE5
L ALL IMPROVEMENTS PER 6RADIN6 PLANS, LA QUUINTA CITY ON5 Na P6 2014-1002 AN7.
1 -
COACHELLA VALLEY HATER P15TRICT SEWER AND WATER PLANS. I
2. THOMA3 BROS. 5OORDINATE5: 200q RIV. CO. (PAGE 3q0, 6RIO C-10) 11 W
3 FEMA MAPPED FLOOD ZONE C, SAID PROPERTY 15 NOT SUBJECT TO OVERFLONW I I
IAUNDATION OR FLOOD HAZARD.
4 NOT :ABJECT TO LIOUEFACTION OR OTHER 6EOLO616 HAZARDS. SAID I {
PROPERTY f5 NOT IN ANY 5FE61AL 5TUDIE5 ZONES.
5. SETBACK5 OF SLOPS TO PROPERTY LINES SHALL CONFORM TO LA OUINTA MUNICIPAL ` !
CODE REQUIREMENTS I I
6. THIS PROJECT l5 LOCATED WITHIN WA5H1N5T0N PARK SPECIFIC PLAN NO. l467-01/ I I
7. THIS PROJECT 15 WITHIN COMMUNITY SERVICE DISTRICT 134 I
6. I EXISTING STRUCTURE UNDER CONSTRUCTION ON SITE i
q. 3 FUTURE 5TRU6TURES OR ONELLIN55 ON 51TE I
/O. NO HAZARDp'Y MATERIALS STORED ON5ITE.
/I. THERE ARE NO KNONN NELL5 ON PROPERTY WITHIN 200' OF SUBJECT
PROPERTY.
12. NO 5,056RFACE SEPTIC FACILITIES ARE PROPOSED I k
13. ALL SLOPES ARE AT A MAXIMUM 2.1 RATIO 1 I
14, ALL OF THE DRAINAGE FACILITIES WITHIN THE SPECIFIC PLAN ARE ROUTED
14lT15ATION BASINS FOR TREATMENT OF RUNOFF 100% RETENTION OF 100 YEAR I
IS. TOTAL NUMBER OF LOTS: 4
BUILDABLE LOTS: 4 l I I
NON -BUILDABLE LOTS: O I W 1
TOTAL 6RO55 A6REA6E 416,134 5F / IOA33 ACRES I i TOTAL NET ACREA6E, 472,2g2 5F / 10.64± ACRES k
AVERA6E NET SIZE 10,,073 51' /-71 ACRES _
MINIMUM LOT 5/ZE, 46,056 5F / 00 ACRES
16 THIS TENTATIVE PARCEL MAP DOES NOT INCLUDE THE ENTIRE CONTI61U0IU5 {yI !r
OWNER5HIP OF THE LAND DIVIDER.
OWNER/APPLICANT ENGINEER
BR2, LLG / LQ LAND COMPANY LLG qmmmfi�
30240 RAALHO OEKJ RD. SUITF B ENO/NEHRS
5AN JUAN CAPI5TRAN0, GA g2675 667q AIRPORT DRIVE
CONTACT: JACK TARR RIVER5IDE, CA g2504
(g4q)443-1234 151-6W6 241
TOPOGRAPHY 50IL5 ENGINEER
TMR A550C/A7E5 5LADDEN EN51NEERINC7
155 K H05PITALITY LN 5TE. 122 TT725 ENFLD LN
5AN BERNARDINC,, CA g2406 PALM DE5ERT, CA g2211
TEL: (qOq) 6qO-3730 TEL: (760) 722-30g3
A55E55OR5 PARCEL NUMBER5
643-020-032
ZONING/LAND U5E
EX6T1N6 ZONING SPECIFIC PLAN SP-Me7-0/1
PROP05EO ZONING- SPECIFIC PLAN 5P 1g67-0I1
EX15TIN6 LANDU5E. GOMMERCIAL/RETAIL
PROPOSED LAN016E: GOMMERCIALIRETAIL
ADJACENT LAND U5E
s
NORTH: REGIONAL COMMERCIAL
SOUTH. GOMMVNITYCOMMERGIAL
EAST: PE610NAL COMMERCIAL (VACANT)
WEST. LOW DEN5ITY RE5IDENTIAL
SHOP UTILITY PURVEYOR5
,h �►
,WATER: COACHELLA VALLEY WA TER DISTRICT
PAD '� �r ✓ �,+ SEWER: VALLEY WATER DISTRICT
THE &AS CO
MPANY
ELECTRIG: LLD,
CO
SI ERJZON
UL I .- I�E �•, \ ✓.9¢i✓✓9h \ �+ + T gLEPHONE: ME AARNER CABLE
A I I fi
i I I LS
Ra
fr
I
II` S I SHOP
11 PAO
�I LS I�
I
"MAP U5ED FOR FINANCIAL PURP05E5 ONLY
L
SHOP
PAO
PA R,
f�C
w
PfiX 2T39
-PA/I-D l J 21 J ._i J J
\ Nor
THEATER
•4 (UNDER
-h \ GON5TRUGT/0N)
SF / 7
5F C !
1$
55,147 5F / 1.27 AG (6)
MJ47 5F.✓J..27 AG (N)
Is
LS
-rx 'S1gR� Y=-� �. �`. LS 516,
9..
SCHOOL: DESERT SANDS UNIFIED
+T LEGAL DESCRIPTION
r'AFL:EL 2 OF PARCEL MAP NO, 30403 EXCEPTING
i RC` M THAT PORTION LYING WITHIN PARCEL
,r MAP 32'03-3
✓/ NIL SEC T55, R7E, SBM
A
\ REA -6ROSS55 METET
� LEGEND PARK/N6 SPACES
/
RE57R16TED AGGE55 TOTAL SPADES � 77/
} (6) GROSS AREA HANDICAP SPACES 16
1}} (A) NET AREA
} BLUE BOARDER
ADA PATH OF TRAVEL
7 w
D 40 L1C
1` 5GALE I"=40'
figNA5 BROS 6GLE PAS-AW,, 6R/D C-lO (200V
-va b
f
1 i � RLVJ5_0l95 �'.
r� x�ceyT,p,+ wr wr.
5ITE DEVELOPMENT MAP NO. 36883
pg[fE35i PREPARATION DATE :.ALINE 2015
4.4
P B-332
30-17 P ENGINEER S
- GNI En) 688- . .'VeyYg . PeMhp
..iSs r1 �, 6879 Ai;p-1 D,;,, R,vers0e, CA 92504
Tel:(951 6BB 0241, Faz:(951) 688-0599
SHFFi �
PhH Dbfe- 6/f
0
m
K
m
Z
ATTAto%URACAIT G
EASEMENT N07E5
® AN EASEMENT OR OTHER PROVI5ION5 FOR THE PURPOSE OF ACCESS AND
RIGHTS INCIDENTAL THERETO A5 5HOWN ON THE RECORDED MAP, WHICH AFFECT5
PAR6EL5 A, B, C, D.
® THE MATTERS CONTAINED IN AN INSTRUMENT ENTITLED RECIPROCAL ACCE55 AND
I I
WATER LINE EASEMENT, BY AND BETWEEN WASHIN&TON III, LTD. AND LOWE5 HIN
I /
INC„ UPON THE TERMS THEREIN PROVIDED RECORDED AU6U5T 6, 2003 AS
INSTRUMENT NO. 0.3-5gb4C2 OF OFFICIAL RECORDS.
T Pp
AFFECT5 PARCEL5 A, B, D
�� 7
® THE MATTERS CONTAINED IN AN INSTRUMENT ENTITLED RECIPROCAL ACCESS
I�
I
EASEMENT, BY AND BETWEEN WA5NINOTON Ill, LTD. AND LOWE5 HIW, INC., AND
TARGET CORPORATION, UPON THE TERM5 THEREIN PROVIDED RECORDED AUr't6T
)
6, 2003 AS INSTRUMENT NO. 00-5gb40I OF OFFICIAL RECORDS.
AFFECT5 PARCEL5 A, B, D
® AN EASEMENT FOR UNDERGROf4W PIPEL INE AND R16NT5 INCIDENTAL THERETO IN
FAVOR OF COACHELLA VALLEY WATER DISTRICT AS SET FORTH IN A DOCUMENT
RECORDED NOVEMBER l7, 2006 AS INSTRUMENT NO. O6-B525BB OF OFFICIAL
RE60RD5, AFFECT5 A SHOWN THEREIN.
1
PROJECT NOTES
IN THE CITY OF LA INTA, C,dii dYTY OF RIVE'RSiD£, 5iA I""a OF GALIFORN/A
TENT
A T/ YE FARGML MAC NO. 36eO3
BE/NC, A PORTION OF THE NORTHEAST OUAR7FR OF SECTION S0, TOANSH/P 5 SOUTH, RANGE 7 EAST
BASED ON THE SAN fiMNARPINO MERIDIAN
NL
" IJ
r rWi�
t
I )
I t
}
I 1 �
1�w
I I �
t
PARG,EL 2
r
4q,7g3 5F / 1.14 AG (6)
s 48,056 SF / 1.10 AG (N)
t II
t � h F_ J
I
� I
r I
G 1
�r
h
y I I Z CATION
I ALL IMPROVEMENTS PER 6RA0 N6 PLAN5, LA 6VINTA CITY Dk,6 No P6 2014-1002 ANf j
COACHELLA VALLEY WATER DI5TRICT SEWER AND WATER PLANS. 11
2 THOMAS EROS. COORDINATES: 2COq R)V. CO. (PA6E 3g0, &RID C-l0)
3. FEMA MAPPED FLOOD ZONE C, SAID PROPERTY 15 NOT SUBJECT TO OVER,
It"UNDATION OR FLOOD HAZARD.
4 NOT 566JECT TO LIQUEFACTION OR OTHER 6EOL0616 HAZAR95. SAID
PROPERTY 15 NOT IN ANY SPECIAL 5TUDIE5 ZONE5.
5. SETBACKS OF SLOPES TO PROPERTY LINES SHALL CONFORM TO LA OUINTA MUNICIPAL
CODE REGUIREMENT5. 6
6. 77415 PROJECT IS LOCATED WITHIN WASHlN5TON PARK SPECIFIC PLAN NO. lg67-01/
7. 7N15 PRO.EC r l5 WITHIN COMhR)NITY SERVICE 015TRICT 04
6. 1 EXI5TIN6 5TRUCTURE UNDER CON5TRUCTION ON 51TE
g. 3 FUTURE STRUCTURES OR DWELLIN65 ON 517E
TO. NO HAZARDOU5 MATERIAL5 5TORED ONSITE.
11. THERE ARE NO KNOWN WELL5 ON PROPERTY WITHIN 200' OF SUBJECT
PROPERTY.
12. NO SUBSURFACE 5EPT16 FACILITIES ARE PROPOSED
13. ALL 5LOPE5 ARE AT A MAXIMUM 2:1 RATIO
14, ALL OF THE DRAINAGE FACILITIES WITHIN THE SPECIFIC PLAN ARE ROUTED TIM
M1Tl6ATION BA5/1,15 FOR TREATMENT OF RUNOFF 10036 RETENTION OF 100-YEAR 5
l5. TOTAL NUMBER OF LOTS: 4
BUILDABLE LOTS: 4
NON -BUILDABLE LOTS: O
TOTAL 6RO55 A6REA6E: 476,13q 5F / IO.g3l ACRES
TOTAL NET ACREAGE: 472,2q2 SF/TO. T ACRES
AVERA6E NET SIZE: 10,073 5F / 2.71 ACRES
MIN/MbM LOT SIZE: 40,,056 5F / 00 A6RE5
16. THIS TENTATIVE PARCEL MAP DOE5 NOT INCLUDE THE ENTIRE CONTl6UG05
OWNER5HIP OF THE LAND L21VICER.
W
1 l
A�1"7,.' CVWD
EASEMENT
I I
2
I�
r
I
I t
6 s
55,530 SF / 1.27 AG (6) \ '
t
53,608 5F / 1.23 AG (N) \
1
I
r
11 P
a
X
g
• r _
rr.
t Y
a y \
\ 315,481 5F / 7.24 AC (6) V A
\ 315,401 5F / 7.24 AG (N)
J Aile, OF, -PJJi JJJDJ /
PAIJE) 2 0,51 r1 J f J 7 �� \
4
l% \
rb a NOV4134'E i i R:61 L /
1w.ar• t.�dg�, � �
J O
FARGEL 4
55,147 5F / 1.27 AG (G)��°pa
55,147 SF / 1.27 AG (N) All
Al- 44 f
'PMAP U5ED FOR FINANCIAL PURP05E5 ONLY
27-392
OWNER/APPLICANT
ENGINEER
BR2, LLG ILO LAND COMPANY LLG two
3024ORANCHO VIE.VR0.5UITEB
ENO/NEE/48
SAN XAN CAP15TR4N0, CA g2675
6B7q AIRPORT DRIVE
CONTACT: JACK TARR
RIVERSIDE, CA g2504
(g4q)443-1234
g5lbM-0241
TOP06RAPHY
5015 ENGINEER
TMR A550CIATE5
5LADDEN EN6/NEERIN5
155 W. H05PITALITYL11 STE 122
7r725 ENFLD LN.
SAN BERNARDINO, CA g2406
PALM DE5ERT, CA g2211
IEL: (q0q) BqC-3730
TEL! (760) 722-3Bg3
A55E550R5 PARCEL NUMBER5
6,4.3-020-032
ZON/N6/LAND U5E
EX15TIN& ZONING: SPECIFIC PLAN - SP-Ige7-011
PROP05ED ZONING: SPECIFIC PLAN - 5P-IgB7-Oil
EX15TIN6 LANDU5E: COMMERCIAL/RETAIL
P:ROP05ELI LANDU5E: COMMERCIAL/RETA/L
AVLk4GENT LAND OW
NoRrm RE6lONAL COMMERCIAL
SOUTH: COMMUNITY COMMERCIAL
EAST: REGIONAL COMMERCIAL (VACANT)
WEST: LOW DENSITY RESIDENTIAL
UTILITY PURVEYOR5
WATER: COACHELLA VALLEY WATER 015TRICT
5EWER: COACHELLA VALLEY WATER 015TRICT
0A5: THE GA5 COMPANY
ELECTRIC: 1,1.D.
TELEPHONE: VEROON
CABLE: TIME WARNER CABLE
SCHOOL: DE5E:RT SANDS UNIFIED
LEGAL DESCRIPTION
P+iRC:ii 2 OF PARCEL MAP NO. 30gO3 EXCEPTING
0CWFRpM THAT PORTION LYING WITHIN PARCEL
MAP 326,93-3
N/E 1/4 5EC 30, T55, R7E, 5BM
AREA - CRO53INET
LEGEND
/ // RE5TRf6TE0ACCE55
(6) 6RO55 AREA
/AU NET AREA
BLUE BOARDER
INDEX
SHEET I - TENTATIVE PARCEL MAP
5HEET 2 - 517E DEVELOPMENT PLAN
.. iu, •a>gw?.
zs�/sm ��'u
lki
Lq
ili.f tu•t+Gw evf �m
TENTATIVE PARCEL MAP NO. 36663
PREPARATION DATE : ,.UNE 2015
3 '
W. 5 3900 � p:lkc
43 / N E E R S
• EXP. 6-39-17
n 4WIL 6B79 Airport Drive, Ri—,id CA 92504
Tel:( , 951) 666-0241,F-:(951) 6666 T
Pki DO, 6/el
0
m
z
PH 2
DIRECTOR'S HEARING
STAFF REPORT
DATE: AUGUST 25, 2015
CASE NUMBER: TENTATIVE PARCEL MAP 2015-0004 (TPM 36856)
APPLICANT: EAST OF MADISON, LLC
PROPERTY OWNER: EAST OF MADISON, LLC
REQUEST: SUBDIVIDE EXISTING .97 ACRE RESIDENTIAL LOT 88 OF
TRACT 33076-2 INTO TWO LOTS
CEQA: EXEMPT FROM FURTHER ENVIRONMENTAL REVIEW
PURSUANT TO SECTION 15315 (CLASS 15 - MINOR LAND
DIVISIONS)
LOCATION: 53-650 FREMONT WAY; LOT 88 OF TRACT MAP 33076-2 IN
THE MADISON CLUB
LEGAL: APN: 767-710-001 AND 767-890-009
RECOMMENDED ACTION:
Approve Tentative Parcel Map 2015-0004 (TPM 36856), subject to the attached
Findings and Conditions of Approval.
EXECUTIVE SUMMARY:
The applicant proposes to subdivide an approximately .97 acre parcel into two parcels
within the Madison Club Country Club (Attachment 1). Staff supports the proposal and
has no significant issues with the proposed subdivision.
BACKGROUND:
This Madison Club Country Club is currently developed with an existing 18-hole golf
course, custom residences, and undeveloped residential lots. An Amendment to
Specific Plan 99-035 and Tentative Tract Map No. 33076 was approved February 1,
2005 for the subdivision of 165 acres into 225 single family lots, 50 detached villas on
33 acres, and an 18-hole golf course on 272 acres. Access to the site is provided from
Avenue 54 and secondary access on Avenue 52.
PAReports - Dir Hrg\2015\08-25-15 DIR HEARING PACKET\PH 2 - TPM 2015-0004 (TPM 36856) Madison Club Lot 88 into two lots\PH 2 (1) TPM 36856
(TPM 2015-0004) REPORT - final draft gp.docx
Page 1 of 3
Lot 88 of Tract 33076-02 is located at the southeastern portion of the Specific Plan
(Attachment 2). The subject property is a single parcel, which was previously
subdivided as part of Tentative Tract Map 33076. The development regulations of the
Specific Plan require a minimum lot size of 10,000 sq. ft., minimum 85 foot lot
frontage, 5 foot interior side yard setbacks, 25 foot front yard setbacks, and 25 foot
rear yard setbacks.
PROPOSAL & ANALYSIS:
Tentative Parcel Map 36856 proposes to subdivide Lot 88, a .97 acre property into two
residential parcels (Attachment 3) as follows:
• Parcel 1 - 28,680 sq. ft.
• Parcel 2 - 29,260 sq. ft.
The proposed subdivision includes a portion of the existing golf course Lot P of Tract
33076-1. The portion of Lot P proposed for the subdivision is currently a passive
landscaped area and will not impact active areas of the golf course once incorporated
into the proposed parcel map. The proposed division does not modify any circulation,
utility service, or other design element of the originally approved Tract Map 33076.
The design of Tentative Parcel Map 36856, as conditioned, conforms to current state,
regional, and local design guidelines and standards including those of the City of La
Quinta General Plan and Municipal Code. The proposed site design incorporates the
interior circulation pattern, infrastructure, and utilities consistent with that of the
previously approved Tract Map 33076 and Specific Plan 99-035. Tentative Parcel Map
36856 is in compliance with the applicable Specific Plan and General Plan goals,
policies, and development standards.
AGENCY AND PUBLIC REVIEW:
Public Agency Review:
This request was sent to all applicable City departments and affected public agencies
on June 30, 2015. All written comments received are on file and available for review
with the Community Development Department. All applicable comments have been
incorporated in the recommended Conditions of Approval.
Public Notice:
This project was advertised in The Desert Sun newspaper on August 14, 2015, and
mailed to all property owners within 500 feet of the site. To date, no comments have
been received from adjacent property owners. Any written comments received will be
handed out at the hearing.
PAReports - Dir Hrg\2015\08-25-15 DIR HEARING PACKET\PH 2 - TPM 2015-0004 (TPM 36856) Madison Club Lot 88 into two lots\PH 2 (1) TPM 36856
(TPM 2015-0004) REPORT - final draft gp.docx
Page 2 of 3
ENVIRONMENTAL REVIEW
The City of La Quinta Community Development Department has determined that this
project is Categorically Exempt from the provisions of the California Environmental
Quality Act (CEQA) pursuant to Section 15315 Class 15 (Minor Land Divisions).
Report prepared and approved for submission by: Gabriel Perez, Planning Manager
Attachments: 1. Project Information
2. Project Area Site Map
3. Tentative Parcel Map 36856
PAReports - Dir Hrg\2015\08-25-15 DIR HEARING PACKET\PH 2 - TPM 2015-0004 (TPM 36856) Madison Club Lot 88 into two lots\PH 2 (1) TPM 36856
(TPM 2015-0004) REPORT - final draft gp.docx
Page 3 of 3
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0004 (TPM 36856)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 1 of 9
FINDINGS
A. The proposed tentative parcel map is consistent with the city General Plan. The
proposed map conforms to the design guidelines and standards of the General Plan
for Low Density Residential designated properties, as set forth in the Land Use
Element while maintaining residential development standards including setbacks,
pad elevations, and other design and performance standards that assure a high
quality of development. Furthermore, the lots proposed are the same size and
configuration of the previously -approved lots prior to their merger, and comply with
the standards of the La Quinta Resort Specific Plan
B. The design or improvement of the proposed tentative parcel map is consistent with
the city General Plan in that its street and parcel design are in conformance with
applicable goals, policies, and development standards, and will provide adequate
infrastructure and public utilities.
C. The design of the tentative parcel map and the proposed improvements are not
likely to cause substantial environmental damage nor substantially injure fish or
wildlife or their habitat. The City of La Quinta Community Development Department
has determined that this project is Categorically Exempt from the provisions of the
California Environmental Quality Act (CEQA) pursuant to Section 15315 Class 15
(Minor Land Divisions).
D. The design of the tentative parcel map and the proposed improvements are not
likely to cause serious public health problems. As conditioned, the proposed
tentative parcel map will not result in any increased hazard to public health or
welfare, as the design has been reviewed by the appropriate responsible agencies for
health and safety issues, with none identified.
E. The site of the proposed tentative parcel map is physically suitable for the type of
development and proposed density of development. As conditioned, the proposed
design of the subdivision is physically compatible with the site with regards to level
topography for the type of land use designation and potential development of the
subject property, and in consideration of existing residential development in the
surrounding area.
F. As conditioned, the proposed tentative parcel map is consistent with all applicable
provisions of this title and the La Quinta Zoning Ordinance, including, but not limited
to, minimum lot area requirements, any other applicable provisions of this code, and
the Subdivision Map Act.
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0004 (TPM 36856)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 2 of 9
G. As conditioned, the design of the tentative parcel map will not conflict with
easements, acquired by the public at large, for access through or use of property
within the proposed subdivision, for access through or use of the property within the
subdivision in that none presently exist and access is provided within the project and
to adjacent public streets.
CONDITIONS OF APPROVAL
GENERAL
1. The applicant agrees to defend, indemnify and hold harmless the City of La Quinta
("City"), its agents, officers and employees from any claim, action or proceeding to
attack, set aside, void, or annul the approval of this Tentative Parcel Map, or any Final
Map recorded thereunder. The City shall have sole discretion in selecting its defense
counsel.
The City shall promptly notify the applicant of any claim, action or proceeding and
shall cooperate fully in the defense.
2. This Tentative Parcel Map, and any Final Map recorded thereunder, shall comply with
the requirements and standards of Government Code §§ 66410 through 66499.58
(the "Subdivision Map Act"), and Chapter 13 of the La Quinta Municipal Code
("LQMC").
The City of La Quinta's Municipal Code can be accessed on the City's Web Site
at www.la-quinta.org.
3. This Tentative Parcel Map shall expire on August 25, 2017, two years from the date
of Director's Hearing approval, unless recorded or granted a time extension pursuant
to the requirements of La Quinta Municipal Code 13.12.160 (Extensions of time for
tentative maps).
4. Prior to the issuance of any grading, construction, or building permit by the City, the
applicant shall obtain any necessary clearances and/or permits from the following
agencies, if required:
• Riverside County Fire Marshal
• La Quinta Public Works Department (Grading Permit, Green Sheet (Public
Works Clearance) for Building Permits, Water Quality Management
FINDINGS AND CONDITIONS OF APPROVAL - RECOMMENDED
TENTATIVE PARCEL MAP 2015-0004 (TPM 36856)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 3 of 9
Plan(WQMP) Exemption Form - Whitewater River Region, Improvement
Permit)
• La Quinta Community Development Department
• Riverside Co. Environmental Health Department
• Desert Sands Unified School District (DSUSD)
• Coachella Valley Water District (CVWD)
• Imperial Irrigation District (IID)
• California Regional Water Quality Control Board (CRWQCB)
• State Water Resources Control Board
• SunLine Transit Agency (SunLine)
• South Coast Air Quality Management District Coachella Valley (SCAQMD)
The applicant is responsible for all requirements of the permits and/or clearances
from the above listed agencies. When these requirements include approval of
improvement plans, the applicant shall furnish proof of such approvals when
submitting those improvement plans for City approval.
5. Permits issued under this approval shall be subject to the provisions of the
Development Impact Fee and Transportation Uniform Mitigation Fee programs in
effect at the time of issuance of building permit(s).
6. Approval of this Tentative Parcel Map shall not be construed as approval for any
horizontal dimensions implied by any site plans or exhibits unless specifically
identified in the following conditions of approval.
7. Developer shall reimburse the City, within thirty (30) days of presentment of the
invoice, all costs and actual attorney's fees incurred by the City Attorney to review,
negotiate and/or modify any documents or instruments required by these
conditions, if Developer requests that the City modify or revise any documents or
instruments prepared initially by the City to effect these conditions. This obligation
shall be paid in the time noted above without deduction or offset and Developer's
failure to make such payment shall be a material breach of the Conditions of
Approval.
8. Developer shall reimburse the City, within thirty (30) days of presentment of the
invoice, all costs and actual consultant's fees incurred by the City for engineering
and/or surveying consultants to review and/or modify any documents or instruments
required by this project. This obligation shall be paid in the time noted above
without deduction or offset and Developer's failure to make such payment shall be a
material breach of the Conditions of Approval.
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0004 (TPM 36856)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 4 of 9
PROPERTY RIGHTS
9. Conferred rights shall include approvals from the HOA over easements and other
property rights necessary for construction and proper functioning of the proposed
development not limited to access rights over proposed and/or existing private
streets that access public streets and open space/drainage facilities of the master
development.
10. The applicant shall offer for dedication on the Final Map a ten -foot wide public utility
easement contiguous with, and along all private streets. Such easement may be
reduced to five feet in width with the express written approval of IID.
11. The applicant shall offer for dedication those easements necessary for the
placement of, and access to, utility lines and structures, drainage basins, mailbox
clusters, park lands, and common areas on the Final Map.
12. The applicant shall furnish proof of easements, or written permission, as appropriate,
from those owners of all abutting properties on which grading, retaining wall
construction, permanent slopes, or other encroachments will occur.
13. The applicant shall cause no easement to be granted, or recorded, over any portion
of the subject property between the date of approval of the Tentative Parcel Map and
the date of recording of any Final Map, unless such easement is approved by the City
Engineer.
14. Improvements including sidewalks shall be designed and constructed in accordance
with City adopted standards, supplemental drawings and specifications, or as
approved by the City Engineer. Improvement plans shall be stamped and signed by
engineers and other professionals registered in California.
MAPS
15. Prior to the City's approval of a Final Map, the applicant shall furnish accurate mylars
of the Final Map. The Final Map shall be 1" = 40' scale.
16. Sheet 2: Please revise the proposed pad elevation shown in Section A -A to 984.5 to
match the plan.
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0004 (TPM 36856)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 5 of 9
IMPROVEMENT PLANS
As used throughout these Conditions of Approval, professional titles such as "engineer,"
"surveyor," and "architect," refer to persons currently certified or licensed to practice their
respective professions in the State of California.
17. Improvement plans shall be prepared by or under the direct supervision of qualified
engineers and/or architects, as appropriate, and shall comply with the provisions of
LQMC Section 13.24.040 (Improvement Plans).
18. The following plans shall be submitted to the Building and Safety Division for review
and approval. The plans shall utilize the minimum scale specified, unless otherwise
authorized by the Building Official in writing. Plans may be prepared at a larger scale
if additional detail or plan clarity is desired. Note, the applicant may be required to
prepare other improvement plans not listed here pursuant to improvements required
by other agencies and utility purveyors.
A. On -Site Residential Precise Grading Plan 1" = 30' Horizontal
Other engineered improvement plans prepared for City approval that are not listed
above shall be prepared in formats approved by the City Engineer prior to
commencing plan preparation.
Grading plans shall normally include perimeter walls with Top Of Wall & Top Of
Footing elevations shown. All footings shall have a minimum of 1-foot of cover, or
sufficient cover to clear any adjacent obstructions.
19. The City maintains standard plans, detail sheets and/or construction notes for
elements of construction which can be accessed via the "Plans, Notes and Design
Guidance" section of the Public Works Department at the City website (www.la-
quinta.org). Please navigate to the Public Works Department home page and look
for the Standard Drawings hyperlink.
20. The applicant shall furnish a complete set of all approved improvement plans on a
storage media acceptable to the City Engineer (currently mylars).
21. Upon completion of construction, and prior to final acceptance of the improvements
by the City, the applicant shall furnish the City with reproducible record drawings of
all improvement plans which were approved by the City. Each sheet shall be clearly
marked "Record Drawing" and shall be stamped and signed by the engineer or
surveyor certifying to the accuracy and completeness of the drawings. The applicant
shall have all approved mylars previously submitted to the City, revised to reflect the
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0004 (TPM 36856)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 6 of 9
as -built conditions. The applicant shall employ or retain the Engineer of Record
during the construction phase of the project so that the FOR can make site visits in
support of preparing "Record Drawing". However, if subsequent approved revisions
have been approved by the City Engineer and reflect said "Record Drawing"
conditions, the Engineer of Record may submit a letter attesting to said fact to the
City Engineer in lieu of mylar submittal.
GRADING
22. The applicant shall comply with the provisions of LQMC Section 13.24.050 (Grading
Improvements).
23. Prior to occupancy of the project site for any construction, the applicant shall obtain
a grading permit approved by the City Engineer.
24. To obtain an approved grading permit, the applicant shall submit and obtain
approval of all of the following:
A. A grading plan prepared by a civil engineer registered in the State of
California,
B. A preliminary geotechnical ("soils") report prepared by a professional
registered in the State of California,
All grading shall conform with the recommendations contained in the Preliminary
Soils Report, and shall be certified as being adequate by soils engineer, or
engineering geologist registered in the State of California.
A statement shall appear on the Final Map that a soils report has been prepared in
accordance with the California Health & Safety Code § 17953.
25. Building pad elevations on the grading plan submitted for City Engineer's approval
shall conform with pad elevations shown on the tentative map, unless the pad
elevations have other requirements imposed elsewhere in these Conditions of
Approval.
26. The applicant shall minimize the differences in elevation between the adjoining
properties and the lots within this development.
27. Prior to any site grading or regrading that will raise or lower any portion of the site by
more than plus or minus half of a foot (0.5') from the elevations shown on the
approved Tentative Parcel Map, the applicant shall submit the proposed grading
FINDINGS AND CONDITIONS OF APPROVAL - RECOMMENDED
TENTATIVE PARCEL MAP 2015-0004 (TPM 36856)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 7 of 9
changes to the City Engineer for a substantial conformance review.
28. Prior to the issuance of a building permit for any building lot, the applicant shall
provide a lot pad certification stamped and signed by a qualified engineer or
surveyor with applicable compaction tests and over excavation documentation.
Each pad certification shall list the pad elevation as shown on the approved grading
plan, the actual pad elevation and the difference between the two, if any. Such pad
certification shall also list the relative compaction of the pad soil. The data shall be
organized by lot number, and listed cumulatively if submitted at different times.
DRAINAGE
29. Stormwater handling shall conform with the approved hydrology and drainage
report for the TM 33076. Nuisance water shall be disposed of in an approved
manner.
The design of the development shall not cause any increase in flood boundaries and
levels in any area outside the development.
30. Storm drainage historically received from adjoining property shall be received and
retained or passed through into the historic downstream drainage relief route.
31. The applicant shall comply with applicable provisions for post construction runoff per
the City's NPDES stormwater discharge permit, LQMC Sections 8.70.010 et seq.
(Stormwater Management and Discharge Controls), and 13.24.170 (Clean Air/Clean
Water); Riverside County Ordinance No. 457; and the California Regional Water
Quality Control Board - Colorado River Basin (CRWQCB-CRB) Region Board Order No.
R7-2013-0011 and the State Water Resources Control Board's Order No. 2009-0009-
DWQ and Order No. 2010-0014-DWQ.
UTILITIES
32. The applicant shall comply with the provisions of LQMC Section 13.24.110 (Utilities).
33. Underground utilities shall be installed prior to overlying hardscape. For installation
of utilities in existing improved streets, the applicant shall comply with trench
restoration requirements maintained, or required by the City Engineer.
The applicant shall provide certified reports of all utility trench compaction for
approval by the City Engineer.
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0004 (TPM 36856)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 8 of 9
MAINTENANCE
34. The applicant shall comply with the provisions of LQMC Section 13.24.160
(Maintenance).
35. The applicant shall make provisions for the continuous and perpetual maintenance
of perimeter landscaping up to the curb, access drives, sidewalks, and stormwater
BMPs.
FEES AND DEPOSITS
36. The applicant shall comply with the provisions of LQMC Section 13.24.180 (Fees and
Deposits). These fees include all deposits and fees required by the City for plan
checking and construction inspection. Deposits and fee amounts shall be those in
effect when the applicant makes application for plan check and permits.
FIRE DEPARTMENT
37. Effective January 1st 2013 all one/two family dwellings and townhouses will require
an automatic residential fire sprinkler system designed and installed in accordance
with section HCD R313.3 or NFPA 13D.
38. For residential areas, approved standard fire hydrants, located at each intersection
and spaced 500 feet apart with no portion of any lot frontage more than 165 feet
from a hydrant. Minimum fire flow shall be 1000 GPM for a 2-hour duration at 20
PSI.
39. For any buildings with public access, provide or show there exists a water system
capable of delivering a fire flow 1000 gallons per minute for 2 hours duration at 20
psi residual operating pressure, which must be available before any combustible
material is placed on the construction site.
40. Prior to building plan approval and construction, applicant/developer shall furnish
two copies of the water system fire hydrant plans to Fire Department for review and
approval. Plans shall be signed by a registered civil engineer, and shall confirm
hydrant type, location, spacing, and minimum fire flow. Once plans are signed and
approved by the local water authority, the originals shall be presented to the Fire
Department for review and approval.
41. Prior to issuance of building permits, the water system for fire protection must be
provided as approved by the Fire Department and the local water authority.
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0004 (TPM 36856)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 9 of 9
42. Fire Apparatus access road shall be in compliance with the Riverside County Fire
Department Standard number 06-05 (located at www.rvcfire.org). Access lanes will
not have an up, or downgrade of more than 15%. Access lanes will be designed to
withstand the weight of 80 thousand pounds over 2 axles. Access will have a turning
radius capable of accommodating fire apparatus. Access lane shall be constructed
with a surface so as to provide all weather driving capabilities.
43. All structures shall be accessible from an approved roadway to within 150 feet of all
portions of the exterior of the first floor.
ATTACHMENT 1
Proiect Information
CASE NUMBER: TENTATIVE PARCEL MAP 2015-0004 (TPM 36856)
APPLICANT: EAST OF MADISON, LLC
PROPERTY OWNER: EAST OF MADISON, LLC
ENGINEER: RCE CONSULTANTS, INC.
REQUEST: SUBDIVIDE EXISTING .97 ACRE RESIDENTIAL LOT 88 OF
TRACT 33076-2 INTO TWO LOTS
LOCATION: 53-650 FREMONT WAY; LOT 88 OF TRACT MAP 33076-2 IN
THE MADISON CLUB
GENERAL PLAN
DESIGNATION: LOW DENSITY RESIDENTIAL
ZONING
DESIGNATION: LOW DENSITY RESIDENTIAL
SURROUNDING
ZONING/LAND USES: NORTH:
GOLF COURSE
EXISTING GOLF COURSE
SOUTH:
GOLF COURSE
EXISTING GOLF COURSE
EAST:
GOLF COURSE
EXISTING GOLF COURSE
WEST:
LOW DENSITY RESIDENTIAL
EXISTING PRIVATE RESIDENCE
MADISON CLUB
U)
w
0
z
LL 2
AVENUE 50
ZI.-
0bi
0Q�
u) AVENUlf 52
AVEN U EI 54
z
PROJECT SITE
PROPOSED TENTATIVE
VICINITY MAP
N.T.S.
OWNER/LAND DIVIDER
NAME: EAST OF MADISON, LLC
ADDRESS: 80955 AVENUE 52
LA QUINTA, CA 92247
PHONE.: 760-391-5072
ENGINEER / MAP PREPARER
NAME: RCE CONSULTANTS, INC.
ADDRESS: 24422 AVENIDA DE LA CARLOTA, SUITE 300
LAGUNA HILLS, CA 92653
PHONE: 949-453-0111
ASSESSORS PARCEL NUMBER
767-710-001
767-890-009
767-890-010
767-890-016
SURVEYOR
NAME: GUIDA SURVEYING INC.
ADDRESS: 9241 IRVINE BLVD.
IRVINE, CA 92618
PHONE: 949-777-2000
FLOOD ZONE
FLOOD ZONE DESIGNATION "X" AS SHOWN ON FEMA PANEL NO.
06065C2261G EFFECTIVE DATE AUGUST 28, 2008.
LEGAL DESCRIPTION
LOT 88 OF TRACT NO. 33076-2, IN THE CITY OF LA QUINTA,
COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS SHOWN BY MAP
ON FILE IN BOOK 393, PAGES 61 THROUGH 80, INCLUSIVE OF MAPS,
IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY; AND
LETTERED LOT P ON TRACT MAP 33076-1, IN THE CITY OF LA
QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, FILED IN
BOOK 388, PAGES 57 THROUGH 79, INCLUSIVE, OF MAPS IN THE
OFFICE OF THE COUNTY RECORDER OF SAID COUNTY.
UTILITIES
COACHELLA VALLEY WATER DISTRICT (760) 398-2651
IMPERIAL IRRIGATION DISTRICT (IID) 1-800-303-7756
THE GAS COMPANY (760) 323-1851
VERIZON 1-800-483-5000
TIME WARNER (760) 340-1312 EXT. 281
UNDERGROUND SERVICE ALERT 1-800-227-2600
DIAL TOLL FREE
1-800-227-2600
AT LEAST TWO DAYS
BEFORE YOU DIG
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
REVISIONS
LEGEND
TRACT BOUNDARY
PROPOSED PROPERTY LINE
EXISTING PROPERTY LINE
EXISTING CENTERLINE
EXISTING PAD LIMIT
PROPOSED PAD LIMIT
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED LOT NUMBER
EXISTING LOT NUMBER
ABBREVIATIONS
AC
ACRE
CENTERLINE
EOP
EDGE OF PAVEMENT
EX
EXISTING
NO
NUMBER
h'
PROPERTY LINE
PROP
PROPOSED
PUE
PUBLIC UTILITY EASEMENT
ROW
RIGHT-OF-WAY
SF
SQUARE FEET
TOPOGRAPHIC NOTES
X
IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA
TENTATIVE PARCEL MAP NO. 36856
SECTION 10, TOWNSHIP 6 SOUTH, RANGE 7 EAST, SAN BERNARDINO MERIDIAN
RCE CONSULTANTS, INC. DATED 12/10/2014
1. TOPOGRAPHIC BASE SHEET IS BASED ON FIELD SURVEY CONDUCTED
06/23/14.
2. UNDERGROUND UTILITIES ARE BASED ON SURVEYED SURFACE FEATURES
AND/OR APPROVED IMPROVEMENT DRAWINGS.
3. TEMPORARY BENCH MARK LOCATED AT EDGE OF PAVEMENT AT THE PRC
ON THE NORTHERLY END OF LOT 79 AND EASTERLY SIDE OF PIKE
PLACE
ADJACENT TENTATIVE & RECORD MAPS
33076-1, 33076-2
PROJECT NOTES
1. HYDROLOGY REPORT IS PER THE PREVIOUSLY APPROVED "HYDROLOGY &
HYDRAULICS STUDY FOR MADISON CLUB (PHASE 1), VOL. IIIA" PREPARED
BY RCE CONSULTANTS, INC. APPROVED DECEMBER 2007.
2. WQMP TO BE SUBMITTED WHEN THE PRECISE GRADING PLAN IS
SUBMITTED FOR FUTURE HOMES.
3. TRAFFIC STUDY PER "MADISON STREET/AVENUE 52 RESIDENTIAL
PROJECT TRAFFIC IMPACT ANALYSIS" PREPARED BY URBAN
CROSSROADS, INC. DATED SEPTEMBER 2004.
4. GEOTECHNICAL REPORT PER "GEOTECHNICAL INVESTIGATION PROPOSED
MADISON CLUB NEC AVENUE 54 & MADISON STREET, LA QUINTA,
CALIFORNIA" PREPARED BY SLADDEN ENGINEERING DATED JANUARY
2005.
5. THE SUPPLEMENTAL REPORTS AND STUDIES (BIOLOGICAL REPORT,
CULTURAL/ARCHAEOLOGICAL REPORT, PALEONTOLOGICAL REPORT, AND
NOISE STUDY) WERE COMPLETED IN CONJUNCTION WITH THE
ENVIRONMENTAL ASSESSMENT 99-380 AND EIR SCH 99061109.
6. SCHOOL DISTRICT: COACHELLA VALLEY UNIFIED SCHOOL DISTRICT
7. EXISTING AND PROPOSED ZONING DESIGNATION: LOW DENSITY
RESIDENTIAL
8. ADJACENT EXISTING AND PROPOSED LAND USE: SPECIFIC PLAN 99-035:
THE MADISON CLUB
9. OFF-STREET PARKING SHALL CONFORM TO SECTION 5.4.1 RESIDENTIAL
DEVELOPMENT STANDARDS PER MADISON CLUB SPECIFIC PLAN 99-035
AMENDMENT #1.
GROSS SITE AREA & NET SITE AREA
THE PROPERTY SHOWN HEREIN CONTAINS THE ENTIRE CONTIGUOUS OWNERSHIP.
TOTAL GROSS AREA: 1.33 AC
TOTAL NO. OF NUMBERED PARCELS: 2
TOTAL NO OF LETTERED FARCES: 1
SIGNATURE
O'Consu Ita nts, Inc.
DESIGNED BY: R.T. CHECKED BY: J.R.
DATE NO. DRAWN BY: R.T. DATE: 12/10/14
3
29
36
37
1 r1nAT1r1AI R A A M
SCALE: 1" = 300'
LOT INFORMATION
LOT NUMBER
AREA
MAX PAD ELEV.
DESIGN PAD ELEV.
LAND USE
1
28,680 SF
991.5
985.0
RESIDENTIAL LOT
2
29,260 SF
991.5
984.5
RESIDENTIAL LOT
P
4,597,330 SF
--
--
GOLF COURSE LOT
NOTE: FOR MODIFICATIONS TO APPROVED GRADING, REFER TO SECTION 6.3.3 OF SPECIFIC PLAN
99-035 AMENDMENT #1
EASEMENT NOTES
NUMBERED AND DESCRIBED PER FIDELITY NATIONAL TITLE COMPANY,
ORDER NO.: 996-23054189-EH1 DATED 10/15/2014
13 EXISTING 22' WIDE PUE EASEMENT PER
TRACT 33076-2/MB 393/61-80
EXISTING 12' WIDE LANDSCAPE AND DRAINAGE EASEMENT PER
14 TRACT 33076-2/MB 393/61-80
A15 EXISTING 22' WIDE IID EASEMENT PER TRACT
33076-2/MB 393/61-80
24422 Avenida De La Carlota.
C46559 Suite 300
P.E. Laguna Hills, Ca. 92653
6-30-15 Phone: 949.453.0111
EXP. Fax: 949.453.0411
SCALE:
1 if = 300'
FILE No.
0502
STAMP
QkODELS/ CgCFZ
NO. C46559 7 A
EXP. 6-30-15
CIVIL �P
BASIS OF BEARINGS
THE NORTH LINE OF THE NW 1 /4
OF SECTION 9, TOWNSHIP 6
SOUTH, RANGE 7 EAST, SAN
BERNARDINO MERIDIAN PER PM
44/67-68 SAID LINE BEARS
N89°46'12"E
T6r, r LL-r -T�
60�
61
N
62
---
63
67 \
68
69
70
71
72
73
74
RESIDENTIAL DEVELOPMENT STANDARDS
(SPECIFIC PLAN 99-035 AMENDMENT #1)
MIN. LOT SIZE
10,000 SF
MIN. LOT FRONTAGE
85'
MAX. STRUCTURE HEIGHT (EXCLUDING BASEMENT)
28'
MAX. NO. OF STORIES
2
MIN. FRONT YARD SETBACK/NON-GARAGE (FROM BACK OF CURB)
25'
MIN. FRONT ENTRY GARAGE SETBACK (FROM BACK OF CURB)
30'
MIN. SIDE ENTRY GARAGE SETBACK
25'
MIN INTERIOR SIDE YARD
5'
MIN. CORNER SIDE YARD
20'
MIN. REARYARD SETBACK
25'
MAX. LOT COVERAGE
50%
MIN. LIVABLE AREA (EXCLUDING GARAGE)
3,500 SF
FOOTNOTES
1. MIN. LOT FRONTAGE ON CURVES, CUL-DE-SACS, AND KNUCKLES SHALL
BE 25'. MIN LOT FRONTAGE FOR FLAG LOTS SHALL BE 15'.
2. ANY PORTION OF A BASEMENT ABOVE ANY FINISH GRADE IS EXCLUDED
FROM CALCULATION OF BUILDING HEIGHT. BUILDINGS WITHIN 150 FEET OF
A GENERAL PLAN IMAGE CORRIDOR (AVENUE 52, AVENUE 54, AND
MADISON STREET) ARE LIMITED TO 22' WITHIN THE 150-FOOT ZONE.
3. ROLL -UP TYPE GARAGE DOORS ARE REQUIRED.
4. FOR INTERIOR SETBACKS, IF THE BUILDING IS OVER 17' IN HEIGHT, THE
SETBACK IS 5' PLUS 1' FOR EVERY FOOT OVER 17' IN HEIGHT OR
FRACTION THEREOF, TO A MAXIMUM REQUIRED SETBACK OF 10'. THE
ADDITIONAL SETBACK MAY B PROVIDED ENTIRELY AT GRADE LEVEL OR A
COMBINATION OF AT GRADE AND AIRSPACE ABOVE THE 17' BUILDING.
5. DEVELOPER RESERVES THE RIGHT TO CONTROL UNIT TYPE THROUGH
DEVELOPMENT REGULATIONS AND THROUGH APPLICATION TO THE CITY
FOR A CONDITIONAL USE PERMIT FOR SPECIAL PRODUCT TYPES,
INCLUDING ATTACHED OR ZERO LOT LINE RESIDENCES.
BENCH MARK APPROVED BY:
ELEV = 972.241
PD 3 3W
MONUMENT IN HANDWELL AT THE
INTERSECTION OF WASHINGTON ST TIMOTHY R. JONASSON, P.E. DATE
& 42 AVENUE ELEV = 117.05' PUBLIC WORKS DIRECTOR/CITY ENGINEER
R.C.E. NO. 45843 EXP. 12-31-16
ATTACHMENT 3
LINE DATA
NUMBER
BEARING
DISTANCE
L1
S71'41'31 "E
27.31'
L2
S5'04'45"W
116.11'
L3
S69'20'59"E
100.00'
L4
S53'53'43"E
190.37'
L5
S87'46'41 "E
146.58'
L6
S80'46'27"E
246.35'
L7
S73*13'36"E
128.62'
L8
S80'00'57"E
123.56'
L9
N87'26'51 "E
120.42'
L10
N48*52'41"E
318.42'
L11
N23'32'16"W
238.63'
L12
N69'06'17"E
421.56'
L13
S10'56'40"E
87.51'
L14
N59'11'34"E
85.73'
L15
N2'02'35"E
321.34'
L16
S55'21'12"E
85.57'
L17
N25'35'44"W
209.60'
L18
N85'16'32"W
152.69'
L19
S36'56'00"W
246.62'
L20
N85'17'43"W
123.77'
L21
S89'43'00"E
158.76'
L22
N76'08'32"E
169.62'
L23
S62'24'41 "W
188.46'
L24
N55'25'16"E
77.26'
L25
S52'31'35"E
48.45'
L26
S87'00'53"E
211.89'
L27
S78'10'20"E
269.73'
L28
N80'18'49"W
142.15'
L29
S86'47'19"W
157.44'
L30
S82'13'23"E
133.44'
L31
N42'10'27"W
85.00'
L32
N1O'17'13"W
85.00'
L33
N14'10'54"E
85.00'
L34
N19'51'47"E
85.00'
L35
N51'17'19"E
85.00'
L36
N73'24'25"E
114.25'
L37
N15'54'56"E
105.94'
L38
N14'47'05"W
93.71'
L39
N35'43'09"W
162.57'
L40
N27'03'38"W
132.17'
L41
S11'27'23"E
259.32'
L42
SO'21'31 "W
135.48'
L43
SO'08'25"E
257.66'
L44
S12'03'08"W
184.17'
L45
S58'25'30"W
283.49'
L46
S3'50'44"W
130.90'
L47
N22'57'38"E
32.64'
L48
N68'30'56"W
152.86'
L49
N54'13'33"E
135.67'
L50
S12'35'05"W
103.30'
L51
N 1 '04'20"E
217.13'
L52
S76'12'16"E
97.76'
L53
N25'50'55"E
61.32'
L54
S23'56'55"E
113.88'
L55
S52'43'13"E
96.40'
L56
N75'54'49"E
63.08'
L57
N28'56'43"E
170.97'
L58
N22'07'57"E
680.44'
L59
NO'56'51"E
30.22'
L60
N28'54'20"E
277.13'
LINE DATA
NUMBER
BEARING
DISTANCE
L61
N23'05'13"W
127.80'
L62
N79'18'36"E
230.58'
L63
S37'51'29"W
72.72'
L64
N61'29'58"W
231.19'
L65
N53'44'51"E
178.84'
L66
NO'54'04"E
75.97'
L67
S22'16'10"E
78.28'
L68
N32'45'40"E
440.97'
L69
S32'25'53"W
151.56'
L70
N 1 '17' 18"W
156.39'
L71
S1O'10'09"W
151.13'
L72
S25'01'58"W
261.51'
L73
S35'57'51"E
107.91'
L74
N83'49'32"E
229.36'
L75
N78'26'41"E
288.66'
L76
S84'09'47"E
243.67'
L77
S16'22'55"E
89.67'
L78
N30'58'48"E
81.46'
L79
S26'02'29"W
179.22'
L80
S6'32'10"W
224.70'
L81
S5'47'32"W
150.55'
L82
S7'43'15"W
150.96'
L83
S11'06'53"W
110.23'
L84
S8'44'47"W
349.55'
L85
S10'37'41 "E
155.34'
L86
S33'44'42"E
159.26'
L87
N41'09'47"W
167.46'
L88
N1334'45"W
131.81'
L89
S11'04'01"E
273.16'
L90
S58'33'23"E
195.35'
CURVE DATA
NUMBER
DELTA
LENGTH
RADIUS
C1
10*41'44"
39.95'
214.00'
C2
43'24'00"
254.51'
336.00'
C3
29'34'38"
226.62'
439.00'
C4
85*10'43"
37.17'
25.00'
C5
6'57'15"
28.89'
238.00'
C6
19'38'40"
81.60'
238.00'
C7
28'39'32"
50.02'
100.00'
C8
69'36'40"
51.03'
42.00'
C9
13'57'44"
218.34'
896.00'
C10
1*18'21"
15.34'
673.08'
C11
82'03'32"
35.80'
25.00'
C12
18*10'46"
145.64'
459.00'
C13
19'20'41"
154.97'
459.00'
C14
29*45'12"
356.24'
686.00'
C15
5*17'43"
84.47'
914.00'
C16
34*08'10"
59.58'
100.00'
C17
78'24'41"
57.48'
42.00'
C18
4'07'43"
145.12'
2014.00'
C19
87'10'45"
38.04'
25.00'
SHEETINDEX
SHEET NO. DESCRIPTION
1 TITLE, VICINITY, AND LOCATION MAPS
2 TENTATIVE PARCEL MAP
IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA
TENTATIVE PARCEL MAP NO. 36856
BEING A SUBDIVISION OF LOT 88 OF TRACT NO. 33076-2
AND LOT T" OF TRACT NO. 33076-1
INDEX SHEET
RAWING NAME:
PM 36856 01 TL
ROJECT No.
0003 MDC
SHEET 1 OF 2
I 0
(984)
AREA TO BE GRADED --- - -
DURING FINAL
IMPROVEMENTS � N�9'18'36 E 0
61.99
- -
0.58' N 23'
�6. - --� 9,
(N34'17'10"W)
3`\ (99.02')
<G-61 R�gS9 _
2 � � � _ _ EXL NEOP�
Opp _ (TYP.)
� l
EX PHASE 2 SEWER _
- � EX PAD
PER -SEWER PLAN - LIMIT (TYP.) �
EXISTING
GOLF TEE
-^ 1\I/ EX ELECTRICAL PAD = 985.0 \ (TYP.)
\ \ oa \ SERVICE
PAD = 23,565 SF
X / 1
EOP�N] 8 1 y- EX PAD N23'05'13"W
ASS V \ LIMIT (TYP.)
65.80
AS '
o •,��'�A \ (PAD = 985.5 PROPOSED PAD /
S V ) LIMIT (TYP.) o
r 0 \ AREA TO BE GRADED
EX WATbR-ME-TER PER 1pbl
\ DURING FINAL �1
-�i�'A l Na � TJ71'8-2 PHASE 2 WATER PLAN'
�� P POSSE, PROPOSED IMPROVEMENTS \ �� y
q e / EX PHASE 2 STORM DRAIN.A SEWER ,\ PROPERTY
/
PER STORM DRAIN PLAN �/ LATERALy j LINE (TYP.)
L Tj-r -F11 EX PHASE 2 WATER
�N57'30'56"E
PER WATER PLAN
237.92'
(PAD = 985.0) \`
PROPOSED \ o
STORM DRAIN PAD = 984.5 / CO
EX ELECTRICAL \\ \\� TYP.) /
�` PROPO D PAD = 227690 SF / �� �9�`li
CONDUIT \ 983.25 e .b
r EX SEWER
LATERAL
PERL� \. EOP � WATER METER
PHASE 2 SEWERPAN ��4�� � � ��� �j�
(TYP.)
PROPOSED PAD 1 1 / d
\ LIMIT (TYP.) EX PROPERTY / O �
r LINE LIMIT (TYP.)4
� '�,�
EX ELECTRICAL r \ �z. _ -
TRANSFORMERS � \ S6, p / / � �^M (PAD = 975.7)
oar \ /
/EX FH PER PHASE 2 V �\ % p
EXISTING GOLF
PAD 985.5 �c�1 WATER PLAN (TYP.) \
( ) / CARTPATH
\ V\iz Lz�
r
EXISTING
FAIRWAY
/ (PAD = 975.9)
EX SEWER LATERAL PER
PHASE 2 SEWER(TYP.)\ / �
O N 2
na1 :� EXPERASE STORMSTORM DRA N DPLAIN \ \ \
PAD = 986.7 / \
CXV
FREMONT WAY \
(PRIVATE STREET) - / 9 3 $ P A /
R/ W 28' R W
/ /
14' 14' 22' t 211 '
PUE & IID EASEMENT PROPOSED PAD = 985.5 1 1 I (PAD = 976.4)
18 SHOULDER REINFORCED 18 SHOULDER REINFORCED
12' LANDSCAPE J\��,�� 8-� I I I \
& DRAINAGE 2.0% 0% e e _ o
,9 _ ;
2 EASEMENT MAC _MgS1 N] 8 :8�y:/ V n I I o ' I
b r I I EXISTING % 3
IGREEN
3.0" A.C. OVER (PAD = 987.0) / \\ GRAPHIC SCALE
DECORATIVE DECORATIVE DRAINAGE SWALE I I
PAVING 4.5" CRUSHED A.B. PAVING
30 0 15 30 60
SECTION A -A 00
— - ----- / ( IN FEET) 00
N.T.S. I I �— n -r _1 inch = 30 ft.
o
_
(PAD 977.1)
24422 Avenida De La Carlota. STAMP BASIS OF BEARINGS BENCH MARK APPROVED BY: IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA DRAWING NAME:
Suite 300
P.E.C46559 Laguna Hills, Ca. 92653 �opROFEss/O,yq� TPM 36856 02
SIGNATURE Phone: 949.453.0111 ��� PLO �� ���� THE NORTH LINE OF THE NW 1/4 ELEV = 972.241 TENTATIVE PARCEL MAP NO. 36856
EXP. 6-30-15 Fax: 949.453.0411 �� ���, OF SECTION 9, TOWNSHIP 6 PROJECT No.
NO. C46559 7 A SOUTH, RANGE 7 EAST, SAN PD 3 3W BEING A SUBDIVISION OF LOT 88 OF TRACT NO. 33076-2 0003 MDC
EXP. 6-30-15 BERNARDINO MERIDIAN PER PM MONUMENT IN HANDWELL AT THE AND LOT "P" OF TRACT NO. 33076-1
O'Co n s u to n ts, Inc. 44/67-68 SAID LINE BEARS INTERSECTION OF WASHINGTON ST TIMOTHY R. JONASSON, P.E. DATE
DESIGNED BY:R.T. CHECKED BY: J.R. SCALE: FILE No. srq/'Z-GFCA0 `P N89°46'12"E & 42 AVENUE ELEV = 117.05' PUBLIC WORKS DIRECTOR/CITY ENGINEER TENTATIVE PARCEL MAP SHEET 2 OF 2
REVISIONS DATE NO -DRAWN BY: R.T. DATE: 12/10/14 1" = 30' 0502 R.C.E. NO. 45843 EXP. 12-31-16
PH 3
DIRECTOR'S HEARING
STAFF REPORT
DATE: AUGUST 25, 2015
CASE NUMBER: TENTATIVE PARCEL MAP 2015-0005 (TPM 36855)
APPLICANT: EAST OF MADISON, LLC
PROPERTY OWNER: EAST OF MADISON, LLC
REQUEST: SUBDIVIDE EXISTING LOT 78 AND 79 OF TRACT MAP 33076-
2 INTO THREE LOTS
CEQA: EXEMPT FROM FURTHER ENVIRONMENTAL REVIEW
PURSUANT TO SECTION 15315 (CLASS 15 - MINOR LAND
DIVISIONS)
LOCATION: 53-710 AND 53-620 PIKE PLACE; EXISTING LOTS 78 AND 79
OF TRACT MAP 33076-2
LEGAL: APN: 767-700-030, 767-700-031, AND 767-890-009
RECOMMENDED ACTION:
Approve Tentative Parcel Map 2015-0005 (TPM 36855), subject to the attached
Findings and Conditions of Approval.
EXECUTIVE SUMMARY:
The applicant proposes to subdivide Lot 79, a .9 acre parcel, and Lot 78, a .82 acre
parcel, into three parcels within the Madison Club Country Club (Attachment 1). Staff
supports the proposal and has no significant issues with the proposed subdivision.
BACKGROUND:
This Madison Club Country Club is currently developed with an existing 18-hole golf
course, custom residences, and significant number of undeveloped residential lots. An
Amendment to Specific Plan 99-035 and Tentative Tract Map No. 33076 was approved
February 1, 2005 for the subdivision of the 165 acres into 225 single family lots, 50
detached villas on 33 acres, and an 18-hole golf course on 272 acres. Access to the
site is provided from Avenue 54 and secondary access on Avenue 52.
PAReports - Dir Hrg\2015\08-25-15 DIR HEARING PACKET\PH 3 - TPM 2015-0005 (TPM 36855) Madison Club Lots 78and 79 into three lots\PH 3 (1) TMP
2015-0005 (TPM 36855) REPORT - final draft gp.docx
Page 1 of 3
Lots 78 and 79 of Tract 33076-02 are located at the southeastern portion of the
Specific Plan (Attachment 2). The subject properties are two residential parcels, which
was previously subdivided as part of Tentative Tract Map 33076. The development
regulations of the Specific Plan include a minimum lot size of 10,000 sq. ft., minimum
85 foot lot frontage, 5 foot interior side yard setbacks, 25 foot front yard setbacks, and
25 foot rear yard setbacks.
PROPOSAL & ANALYSIS:
Tentative Parcel Map 36855 proposes to subdivide Lot 79, a .9 acre parcel, and Lot 78,
a 0.82 acre parcel, into three residential parcels (Attachment 3) as follows:
• Parcel 1 - 20,400 sq. ft.
• Parcel 2 - 26,930 sq. ft.
• Parcel 3 - 33,380 sq. ft.
The proposed subdivision includes a portion of the existing gold course lot, Lot P of
Tract 33076-1. The portion of Lot P proposed for the subdivision is currently a passive
landscaped area and will not impact active areas of the golf course once incorporated
into the proposed parcel map. The proposed division does not modify any circulation,
utility service, or other design element of the originally approved Tract Map 33076.
The design of Tentative Parcel Map 36855, as conditioned, conforms to current state,
regional, and local design guidelines and standards including those of the City of La
Quinta General Plan and Municipal Code. The proposed site design incorporates the
interior circulation pattern, infrastructure, and utilities consistent with that of the
previously approved Tract Map 33076 and Specific Plan 99-035. Tentative Parcel Map
36855 is in compliance with the applicable Specific Plan and General Plan goals,
policies, and development standards.
AGENCY AND PUBLIC REVIEW:
Public Agency Review:
This request was sent to all applicable City departments and affected public agencies
on June 30, 2015. All written comments received are on file and available for review
with the Community Development Department. All applicable comments have been
incorporated in the recommended Conditions of Approval.
Public Notice:
This project was advertised in The Desert Sun newspaper on August 14, 2015, and
mailed to all property owners within 500 feet of the site. To date, no comments have
been received from adjacent property owners. Any written comments received will be
handed out at the hearing.
PAReports - Dir Hrg\2015\08-25-15 DIR HEARING PACKET\PH 3 - TPM 2015-0005 (TPM 36855) Madison Club Lots 78and 79 into three lots\PH 3 (1) TMP
2015-0005 (TPM 36855) REPORT - final draft gp.docx
Page 2 of 3
ENVIRONMENTAL REVIEW
The City of La Quinta Community Development Department has determined that this
project is Categorically Exempt from the provisions of the California Environmental
Quality Act (CEQA) pursuant to Section 15315 Class 15 (Minor Land Divisions).
Report prepared and approved for submission by: Gabriel Perez, Planning Manager
Attachments: 1. Project Information
2. Project Area Site Map
3. Tentative Parcel Map 36855
PAReports - Dir Hrg\2015\08-25-15 DIR HEARING PACKET\PH 3 - TPM 2015-0005 (TPM 36855) Madison Club Lots 78and 79 into three lots\PH 3 (1) TMP
2015-0005 (TPM 36855) REPORT - final draft gp.docx
Page 3 of 3
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0005 (TPM 36855)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 1 of 9
FINDINGS
A. The proposed tentative parcel map is consistent with the city General Plan. The
proposed map conforms to the design guidelines and standards of the General Plan
for Low Density Residential designated properties, as set forth in the Land Use
Element while maintaining residential development standards including setbacks,
pad elevations, and other design and performance standards that assure a high
quality of development. Furthermore, the lots proposed are the same size and
configuration of the previously -approved lots prior to their merger, and comply with
the standards of the La Quinta Resort Specific Plan
B. The design or improvement of the proposed tentative parcel map is consistent with
the city General Plan in that its street and parcel design are in conformance with
applicable goals, policies, and development standards, and will provide adequate
infrastructure and public utilities.
C. The design of the tentative parcel map and the proposed improvements are not
likely to cause substantial environmental damage nor substantially injure fish or
wildlife or their habitat. The City of La Quinta Community Development Department
has determined that this project is Categorically Exempt from the provisions of the
California Environmental Quality Act (CEQA) pursuant to Section 15315 Class 15
(Minor Land Divisions).
D. The design of the tentative parcel map and the proposed improvements are not
likely to cause serious public health problems. As conditioned, the proposed
tentative parcel map will not result in any increased hazard to public health or
welfare, as the design has been reviewed by the appropriate responsible agencies for
health and safety issues, with none identified.
E. The site of the proposed tentative parcel map is physically suitable for the type of
development and proposed density of development. As conditioned, the proposed
design of the subdivision is physically compatible with the site with regards to level
topography for the type of land use designation and potential development of the
subject property, and in consideration of existing residential development in the
surrounding area.
F. As conditioned, the proposed tentative parcel map is consistent with all applicable
provisions of this title and the La Quinta Zoning Ordinance, including, but not limited
to, minimum lot area requirements, any other applicable provisions of this code, and
the Subdivision Map Act.
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0005 (TPM 36855)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 2 of 9
G. As conditioned, the design of the tentative parcel map will not conflict with
easements, acquired by the public at large, for access through or use of property
within the proposed subdivision, for access through or use of the property within the
subdivision in that none presently exist and access is provided within the project and
to adjacent public streets.
CONDITIONS OF APPROVAL
GENERAL
1. The applicant agrees to defend, indemnify and hold harmless the City of La Quinta
("City"), its agents, officers and employees from any claim, action or proceeding to
attack, set aside, void, or annul the approval of this Tentative Parcel Map, or any Final
Map recorded thereunder. The City shall have sole discretion in selecting its defense
counsel.
The City shall promptly notify the applicant of any claim, action or proceeding and
shall cooperate fully in the defense.
2. This Tentative Parcel Map, and any Final Map recorded thereunder, shall comply with
the requirements and standards of Government Code §§ 66410 through 66499.58
(the "Subdivision Map Act"), and Chapter 13 of the La Quinta Municipal Code
("LQMC").
The City of La Quinta's Municipal Code can be accessed on the City's Web Site
at www.la-quinta.org.
3. This Tentative Parcel Map shall expire on August 25, 2017, two years from the date
of Director's Hearing approval, unless recorded or granted a time extension pursuant
to the requirements of La Quinta Municipal Code 13.12.160 (Extensions of time for
tentative maps).
4. Prior to the issuance of any grading, construction, or building permit by the City, the
applicant shall obtain any necessary clearances and/or permits from the following
agencies, if required:
• Riverside County Fire Marshal
• La Quinta Public Works Department (Grading Permit, Green Sheet (Public
Works Clearance) for Building Permits, Water Quality Management
FINDINGS AND CONDITIONS OF APPROVAL - RECOMMENDED
TENTATIVE PARCEL MAP 2015-0005 (TPM 36855)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 3 of 9
Plan(WQMP) Exemption Form - Whitewater River Region, Improvement
Permit)
• La Quinta Community Development Department
• Riverside Co. Environmental Health Department
• Desert Sands Unified School District (DSUSD)
• Coachella Valley Water District (CVWD)
• Imperial Irrigation District (IID)
• California Regional Water Quality Control Board (CRWQCB)
• State Water Resources Control Board
• SunLine Transit Agency (SunLine)
• South Coast Air Quality Management District Coachella Valley (SCAQMD)
The applicant is responsible for all requirements of the permits and/or clearances
from the above listed agencies. When these requirements include approval of
improvement plans, the applicant shall furnish proof of such approvals when
submitting those improvement plans for City approval.
5. Permits issued under this approval shall be subject to the provisions of the
Development Impact Fee and Transportation Uniform Mitigation Fee programs in
effect at the time of issuance of building permit(s).
6. Approval of this Tentative Parcel Map shall not be construed as approval for any
horizontal dimensions implied by any site plans or exhibits unless specifically
identified in the following conditions of approval.
7. Developer shall reimburse the City, within thirty (30) days of presentment of the
invoice, all costs and actual attorney's fees incurred by the City Attorney to review,
negotiate and/or modify any documents or instruments required by these
conditions, if Developer requests that the City modify or revise any documents or
instruments prepared initially by the City to effect these conditions. This obligation
shall be paid in the time noted above without deduction or offset and Developer's
failure to make such payment shall be a material breach of the Conditions of
Approval.
8. Developer shall reimburse the City, within thirty (30) days of presentment of the
invoice, all costs and actual consultant's fees incurred by the City for engineering
and/or surveying consultants to review and/or modify any documents or instruments
required by this project. This obligation shall be paid in the time noted above
without deduction or offset and Developer's failure to make such payment shall be a
material breach of the Conditions of Approval.
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0005 (TPM 36855)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 4 of 9
PROPERTY RIGHTS
9. Conferred rights shall include approvals from the HOA over easements and other
property rights necessary for construction and proper functioning of the proposed
development not limited to access rights over proposed and/or existing private
streets that access public streets and open space/drainage facilities of the master
development.
10. The applicant shall offer for dedication on the Final Map a ten -foot wide public utility
easement contiguous with, and along all private streets. Such easement may be
reduced to five feet in width with the express written approval of IID.
11. The applicant shall offer for dedication those easements necessary for the
placement of, and access to, utility lines and structures, drainage basins, mailbox
clusters, park lands, and common areas on the Final Map.
12. The applicant shall furnish proof of easements, or written permission, as appropriate,
from those owners of all abutting properties on which grading, retaining wall
construction, permanent slopes, or other encroachments will occur.
13. The applicant shall cause no easement to be granted, or recorded, over any portion
of the subject property between the date of approval of the Tentative Parcel Map and
the date of recording of any Final Map, unless such easement is approved by the City
Engineer.
14. Improvements including sidewalks shall be designed and constructed in accordance
with City adopted standards, supplemental drawings and specifications, or as
approved by the City Engineer. Improvement plans shall be stamped and signed by
engineers and other professionals registered in California.
MAPS
15. Prior to the City's approval of a Final Map, the applicant shall furnish accurate mylars
of the Final Map. The Final Map shall be 1" = 40' scale.
16. Sheet 2: Please revise the proposed pad elevation shown in Section A -A to 984.5 to
match the plan.
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0005 (TPM 36855)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 5 of 9
IMPROVEMENT PLANS
As used throughout these Conditions of Approval, professional titles such as "engineer,"
"surveyor," and "architect," refer to persons currently certified or licensed to practice their
respective professions in the State of California.
17. Improvement plans shall be prepared by or under the direct supervision of qualified
engineers and/or architects, as appropriate, and shall comply with the provisions of
LQMC Section 13.24.040 (Improvement Plans).
18. The following plans shall be submitted to the Building and Safety Division for review
and approval. The plans shall utilize the minimum scale specified, unless otherwise
authorized by the Building Official in writing. Plans may be prepared at a larger scale
if additional detail or plan clarity is desired. Note, the applicant may be required to
prepare other improvement plans not listed here pursuant to improvements required
by other agencies and utility purveyors.
A. On -Site Residential Precise Grading Plan 1" = 30' Horizontal
Other engineered improvement plans prepared for City approval that are not listed
above shall be prepared in formats approved by the City Engineer prior to
commencing plan preparation.
Grading plans shall normally include perimeter walls with Top Of Wall & Top Of
Footing elevations shown. All footings shall have a minimum of 1-foot of cover, or
sufficient cover to clear any adjacent obstructions.
19. The City maintains standard plans, detail sheets and/or construction notes for
elements of construction which can be accessed via the "Plans, Notes and Design
Guidance" section of the Public Works Department at the City website (www.la-
quinta.org). Please navigate to the Public Works Department home page and look
for the Standard Drawings hyperlink.
20. The applicant shall furnish a complete set of all approved improvement plans on a
storage media acceptable to the City Engineer (currently mylars).
21. Upon completion of construction, and prior to final acceptance of the improvements
by the City, the applicant shall furnish the City with reproducible record drawings of
all improvement plans which were approved by the City. Each sheet shall be clearly
marked "Record Drawing" and shall be stamped and signed by the engineer or
surveyor certifying to the accuracy and completeness of the drawings. The applicant
shall have all approved mylars previously submitted to the City, revised to reflect the
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0005 (TPM 36855)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 6 of 9
as -built conditions. The applicant shall employ or retain the Engineer of Record
during the construction phase of the project so that the FOR can make site visits in
support of preparing "Record Drawing". However, if subsequent approved revisions
have been approved by the City Engineer and reflect said "Record Drawing"
conditions, the Engineer of Record may submit a letter attesting to said fact to the
City Engineer in lieu of mylar submittal.
GRADING
22. The applicant shall comply with the provisions of LQMC Section 13.24.050 (Grading
Improvements).
23. Prior to occupancy of the project site for any construction, the applicant shall obtain
a grading permit approved by the City Engineer.
24. To obtain an approved grading permit, the applicant shall submit and obtain
approval of all of the following:
A. A grading plan prepared by a civil engineer registered in the State of
California,
B. A preliminary geotechnical ("soils") report prepared by a professional
registered in the State of California,
All grading shall conform with the recommendations contained in the Preliminary
Soils Report, and shall be certified as being adequate by soils engineer, or
engineering geologist registered in the State of California.
A statement shall appear on the Final Map that a soils report has been prepared in
accordance with the California Health & Safety Code § 17953.
25. Building pad elevations on the grading plan submitted for City Engineer's approval
shall conform with pad elevations shown on the tentative map, unless the pad
elevations have other requirements imposed elsewhere in these Conditions of
Approval.
26. The applicant shall minimize the differences in elevation between the adjoining
properties and the lots within this development.
27. Prior to any site grading or regrading that will raise or lower any portion of the site by
more than plus or minus half of a foot (0.5') from the elevations shown on the
approved Tentative Parcel Map, the applicant shall submit the proposed grading
FINDINGS AND CONDITIONS OF APPROVAL - RECOMMENDED
TENTATIVE PARCEL MAP 2015-0005 (TPM 36855)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 7 of 9
changes to the City Engineer for a substantial conformance review.
28. Prior to the issuance of a building permit for any building lot, the applicant shall
provide a lot pad certification stamped and signed by a qualified engineer or
surveyor with applicable compaction tests and over excavation documentation.
Each pad certification shall list the pad elevation as shown on the approved grading
plan, the actual pad elevation and the difference between the two, if any. Such pad
certification shall also list the relative compaction of the pad soil. The data shall be
organized by lot number, and listed cumulatively if submitted at different times.
DRAINAGE
29. Stormwater handling shall conform with the approved hydrology and drainage
report for the TM 33076. Nuisance water shall be disposed of in an approved
manner.
The design of the development shall not cause any increase in flood boundaries and
levels in any area outside the development.
30. Storm drainage historically received from adjoining property shall be received and
retained or passed through into the historic downstream drainage relief route.
31. The applicant shall comply with applicable provisions for post construction runoff per
the City's NPDES stormwater discharge permit, LQMC Sections 8.70.010 et seq.
(Stormwater Management and Discharge Controls), and 13.24.170 (Clean Air/Clean
Water); Riverside County Ordinance No. 457; and the California Regional Water
Quality Control Board - Colorado River Basin (CRWQCB-CRB) Region Board Order No.
R7-2013-0011 and the State Water Resources Control Board's Order No. 2009-0009-
DWQ and Order No. 2010-0014-DWQ.
UTILITIES
32. The applicant shall comply with the provisions of LQMC Section 13.24.110 (Utilities).
33. Underground utilities shall be installed prior to overlying hardscape. For installation
of utilities in existing improved streets, the applicant shall comply with trench
restoration requirements maintained, or required by the City Engineer.
The applicant shall provide certified reports of all utility trench compaction for
approval by the City Engineer.
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0005 (TPM 36855)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 8 of 9
MAINTENANCE
34. The applicant shall comply with the provisions of LQMC Section 13.24.160
(Maintenance).
35. The applicant shall make provisions for the continuous and perpetual maintenance
of perimeter landscaping up to the curb, access drives, sidewalks, and stormwater
BMPs.
FEES AND DEPOSITS
36. The applicant shall comply with the provisions of LQMC Section 13.24.180 (Fees and
Deposits). These fees include all deposits and fees required by the City for plan
checking and construction inspection. Deposits and fee amounts shall be those in
effect when the applicant makes application for plan check and permits.
FIRE DEPARTMENT
37. Effective January 1st 2013 all one/two family dwellings and townhouses will require
an automatic residential fire sprinkler system designed and installed in accordance
with section HCD R313.3 or NFPA 13D.
38. For residential areas, approved standard fire hydrants, located at each intersection
and spaced 500 feet apart with no portion of any lot frontage more than 165 feet
from a hydrant. Minimum fire flow shall be 1000 GPM for a 2-hour duration at 20
PSI.
39. For any buildings with public access, provide or show there exists a water system
capable of delivering a fire flow 1000 gallons per minute for 2 hours duration at 20
psi residual operating pressure, which must be available before any combustible
material is placed on the construction site.
40. Prior to building plan approval and construction, applicant/developer shall furnish
two copies of the water system fire hydrant plans to Fire Department for review and
approval. Plans shall be signed by a registered civil engineer, and shall confirm
hydrant type, location, spacing, and minimum fire flow. Once plans are signed and
approved by the local water authority, the originals shall be presented to the Fire
Department for review and approval.
41. Prior to issuance of building permits, the water system for fire protection must be
provided as approved by the Fire Department and the local water authority.
FINDINGS AND CONDITIONS OF APPROVAL — RECOMMENDED
TENTATIVE PARCEL MAP 2015-0005 (TPM 36855)
THE MADISON CLUB
ADOPTED: AUGUST 25, 2015
Page 9 of 9
42. Fire Apparatus access road shall be in compliance with the Riverside County Fire
Department Standard number 06-05 (located at www.rvcfire.org). Access lanes will
not have an up, or downgrade of more than 15%. Access lanes will be designed to
withstand the weight of 80 thousand pounds over 2 axles. Access will have a turning
radius capable of accommodating fire apparatus. Access lane shall be constructed
with a surface so as to provide all weather driving capabilities.
43. All structures shall be accessible from an approved roadway to within 150 feet of all
portions of the exterior of the first floor.
ATTACHMENT 1
Project Information
CASE NUMBER: TENTATIVE PARCEL MAP 2015-0005 (TPM 36855)
APPLICANT: EAST OF MADISON, LLC
PROPERTY OWNER: EAST OF MADISON, LLC
ENGINEER: RCE CONSULTANTS, INC.
REQUEST: SUBDIVIDE EXISTING LOT 78 AND 79 OF TRACT 33076-2
INTO THREE LOTS
LOCATION: 53-710 AND 53-620 PIKE PLACE; EXISTING LOTS 78 AND 79
OF TRACT MAP 33076-2
GENERAL PLAN
DESIGNATION: LOW DENSITY RESIDENTIAL
ZONING
DESIGNATION: LOW DENSITY RESIDENTIAL
SURROUNDING
ZONING/LAND USES: NORTH:
GOLF COURSE
EXISTING GOLF COURSE
SOUTH:
GOLF COURSE
EXISTING GOLF COURSE
EAST:
GOLF COURSE
EXISTING GOLF COURSE
WEST:
LOW DENSITY RESIDENTIAL
VACANT RESIDENTIAL LOTS
ATTACHMENT 2
Site
'°�`•"---"^ram
r
�.w,�
►TTACHMENT 2- Parcel 36855 wF
TMP 2015-0005
P..
K
a
r r
t
i,
I I kill.
City of La Quinta
Planning Division
Community Development Department
MADISON CLUB
VICINITY MAP
N.T.S.
OWNER/LAND DIVIDER
NAME: EAST OF MADISON, LLC
ADDRESS: 80955 AVENUE 52
LA QUINTA, CA 92247
PHONE.: 760-391-5072
ENGINEER / MAP PREPARER
PROJECT SITE
DSED TENTATIVE
NAME: RCE CONSULTANTS, INC.
ADDRESS: 24422 AVENIDA DE LA CARLOTA, SUITE 300
LAGUNA HILLS, CA 92653
PHONE: 949-453-0111
ASSESSORS PARCEL NUMBER
767-700-030
767-700-031
767-890-009
767-890-010
767-890-016
SURVEYOR
NAME: GUIDA SURVEYING INC.
ADDRESS: 9241 IRVINE BLVD.
IRVINE, CA 92618
PHONE: 949-777-2000
FLOOD ZONE
FLOOD ZONE DESIGNATION "X" AS SHOWN ON FEMA PANEL NO.
06065C2261G EFFECTIVE DATE AUGUST 28, 2008.
LEGAL DESCRIPTION
LOTS 78 AND 79 OF TRACT NO. 33076-2, IN THE CITY OF LA
QUINTA, AS SHOWN BY MAP ON FILE IN BOOK 393, PAGE(S) 61
THROUGH 80, INCLUSIVE OF MAPS, IN THE OFFICE OF THE COUNTY
RECORDER OF RIVERSIDE COUNTY, CALIFORNIA; AND LETTERED LOT P
ON TRACT MAP 33076-1, IN THE CITY OF LA QUINTA, COUNTY OF
RIVERSIDE, STATE OF CALIFORNIA, FILED IN BOOK 388, PAGES 57
THROUGH 79, INCLUSIVE, OF MAPS, IN THE OFFICE OF THE COUNTY
RECORDER OF SAID COUNTY.
UTILITIES
COACHELLA VALLEY WATER DISTRICT
IMPERIAL IRRIGATION DISTRICT (IID)
THE GAS COMPANY
VERIZON
TIME WARNER
UNDERGROUND SERVICE ALERT
(760) 398-2651
1-800-303-7756
(760) 323-1851
1-800-483-5000
(760) 340-1312 EXT. 281
1-800-227-2600
DIAL TOLL FREE
1-800-227-2600
AT LEAST TWO DAYS
BEFORE YOU DIG
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
REVISIONS
LEGEND
TRACT BOUNDARY
PROPOSED PROPERTY LINE
EXISTING PROPERTY LINE
EXISTING CENTERLINE
EXISTING PAD LIMIT
PROPOSED PAD LIMIT
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED LOT NUMBER
EXISTING LOT NUMBER
ABBREVIATIONS
AC
ACRE
CENTERLINE
EOP
EDGE OF PAVEMENT
EX
EXISTING
NO
NUMBER
h'
PROPERTY LINE
PROP
PROPOSED
PUE
PUBLIC UTILITY EASEMENT
ROW
RIGHT-OF-WAY
SF
SQUARE FEET
IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA
TENTATIVE PARCEL MAP NO. 36855
SECTION 10, TOWNSHIP 6 SOUTH, RANGE 7 EAST, SAND BERNARDINO MERIDIAN
21
22
J
RCE CONSULTANTS, INC. DATED 12/10/2014
52 53 L2 54 ° � � F / TJ7 -:2 \
r59
\1 L26 L27 60
L28 L29 L30 X61
N
J
62
J
63
6 64
29 51
X 65
� _ �p LOT "P" �
30 50 TRACT NO. 33076-1
LOT "P" M.B. 388/57-79
31 � TRACT NO. 33076-1 �6�
T 49 M.B.388/57-79 89 66 C76 67
00 C15 L58 <Q
- - � is o
TOPOGRAPHIC NOTES
1. TOPOGRAPHIC BASE SHEET IS BASED ON FIELD SURVEY CONDUCTED
06/23/14.
2. UNDERGROUND UTILITIES ARE BASED ON SURVEYED SURFACE FEATURES
AND/OR APPROVED IMPROVEMENT DRAWINGS.
3. TEMPORARY BENCH MARK LOCATED AT EDGE OF PAVEMENT AT THE PRC
ON THE NORTHERLY END OF LOT 79 AND EASTERLY SIDE OF PIKE
PLACE
ADJACENT TENTATIVE & RECORD MAPS
33076-1, 33076-2
PROJECT NOTES
1. HYDROLOGY REPORT IS PER THE PREVIOUSLY APPROVED "HYDROLOGY &
HYDRAULICS STUDY FOR MADISON CLUB (PHASE 1), VOL. IIIA" PREPARED
BY RCE CONSULTANTS, INC. APPROVED DECEMBER 2007.
2. WQMP TO BE SUBMITTED WHEN THE PRECISE GRADING PLAN IS
SUBMITTED FOR FUTURE HOMES.
3. TRAFFIC STUDY PER "MADISON STREET/AVENUE 52 RESIDENTIAL
PROJECT TRAFFIC IMPACT ANALYSIS" PREPARED BY URBAN
CROSSROADS, INC. DATED SEPTEMBER 2004.
4. GEOTECHNICAL REPORT PER "GEOTECHNICAL INVESTIGATION PROPOSED
MADISON CLUB NEC AVENUE 54 & MADISON STREET, LA QUINTA,
CALIFORNIA" PREPARED BY SLADDEN ENGINEERING DATED JANUARY
2005.
5. THE SUPPLEMENTAL REPORTS AND STUDIES (BIOLOGICAL REPORT,
CULTURAL/ARCHAEOLOGICAL REPORT, PALEONTOLOGICAL REPORT, AND
NOISE STUDY) WERE COMPLETED IN CONJUNCTION WITH THE
ENVIRONMENTAL ASSESSMENT 99-380 AND EIR SCH 99061109.
6. SCHOOL DISTRICT: COACHELLA VALLEY UNIFIED SCHOOL DISTRICT
7. EXISTING AND PROPOSED ZONING DESIGNATION: LOW DENSITY
RESIDENTIAL
8. ADJACENT EXISTING AND PROPOSED LAND USE: SPECIFIC PLAN 99-035:
THE MADISON CLUB
9. OFF-STREET PARKING SHALL CONFORM TO SECTION 5.4.1 RESIDENTIAL
DEVELOPMENT STANDARDS PER MADISON CLUB SPECIFIC PLAN 99-035
AMENDMENT #1.
GROSS SITE AREA & NET SITE AREA
THE PROPERTY SHOWN HEREIN CONTAINS THE ENTIRE CONTIGUOUS OWNERSHIP.
TOTAL GROSS AREA: 1.85 AC
TOTAL NO. OF NUMBERED PARCELS: 3
TOTAL NO OF LETTERED PARCELS: 1
SIGNATURE
O'Consu Ita nts, Inc.
DESIGNED BY:R.T. CHECKED BY: J.R.
DATE NO. DRAWN BY: R.T. DATE: 12/10/14
------r ---- 23 / � 71 69 70 68 02
C18 ; �:1J 67,/66
65 64
24 RY
cli � <�
C� J
43 55 56`rr 4
2
54 L5
L6
53 5
��-
0
\cr 52 rn.
.. 63
gg��� 62
61
L9
L8
PROPOSED LOT
LINES (TYP.)
,76
L18
vle
49 50 51
1
L20 L21 L22
< - �
32 48 J 90 c �` 68
91 ham' 80 s
- - - .81
33 CO C73
Z� rya 47 92 L65 L55 69
o vo 93 C�2 L64 <01 82
�� . 46 95 ���� 88 83 �`� L5 C7
34 � 94 70
0
4
96 °�� lb 0 84 --
35 � LOT "Q„ � 1 71
00 � 97 85 L52
36 0 �� - 101 <� 862 J 72
re 44 000 N 98 037 �� o _' _j 102 100 `� L61_ 87 3 J
`L --- 99 C9 73
43 - 448 L50
/ I w N 103 -
C4 � c� 74
109 110 111 112 113 114 115 116 117 118 119 SHEET
106
42 ,� 104 107 108 �� ° �a � e e F - � �� /120 � 75
_ \
-�
41 �o `' 105 LOT "R11 121 L46
L76 S .
`-> L78 L77 \ �� 122 r
j
LOCATION MAP
SCALE: 1" = 300'
h
0
LOT INFORMATION
LOT NUMBER
AREA
MAX PAD
ELEV.
DESIGN PAD
ELEV.
LAND USE
1
20,400 SF
982.5
975.9
RESIDENTIAL LOT
2
26,930 SF
982.0
976.0
RESIDENTIAL LOT
3
33,380 SF
981.9
976.5
RESIDENTIAL LOT
P
4,600,680 SF
--
GOLF COURSE LOT
NOTE: FOR MODIFICATIONS TO APPROVED GRADING, REFER TO SECTION 6.3.3 OF SPECIFIC PLAN
99-035 AMENDMENT #1
EASEMENT NOTES
NUMBERED AND DESCRIBED PER FIDELITY NATIONAL TITLE COMPANY,
ORDER NO.: 996-23054188-EH1 DATED 10/15/2014
13 EXISTING 22' WIDE PUE EASEMENT PER
TRACT 33076-2/MB 393/61-80
EXISTING 12' WIDE LANDSCAPE AND DRAINAGE EASEMENT PER
14 TRACT 33076-2/MB 393/61-80
AEXISTING 22' WIDE IID EASEMENT PER TRACT
A
33076-2/MB 393/61-80
AEXISTING 26' WIDE STORM DRAIN EASEMENT
A
PER TRACT 33076-1/MB 388/57-79
24422 Avenida De La Carlota.
C46559 Suite 300
P.E. Laguna Hills, Ca. 92653
6-30-15 Phone: 949.453.0111
EXP. Fax: 949.453.0411
SCALE:
1 if = 300'
FILE No.
0502
STAMP
QkODELS/ C4z
P
C �.
� v� -7
NO. C46559 7 A
EXP. 6-30-15
\ CIVIL �P
\q' GF CALIF
BASIS OF BEARINGS
THE NORTH LINE OF THE NW 1 /4
OF SECTION 9, TOWNSHIP 6
SOUTH, RANGE 7 EAST, SAN
BERNARDINO MERIDIAN PER PM
44/67-68 SAID LINE BEARS
N89°46'12"E
RESIDENTIAL DEVELOPMENT STANDARDS
(SPECIFIC PLAN 99-035 AMENDMENT #1)
MIN. LOT SIZE
10,000 SF
MIN. LOT FRONTAGE
85'
MAX. STRUCTURE HEIGHT (EXCLUDING BASEMENT)
28'
MAX. NO. OF STORIES
2
MIN. FRONT YARD SETBACK/NON-GARAGE (FROM BACK OF CURB)
25'
MIN. FRONT ENTRY GARAGE SETBACK (FROM BACK OF CURB)
30'
MIN. SIDE ENTRY GARAGE SETBACK
25'
MIN INTERIOR SIDE YARD
5'
MIN. CORNER SIDE YARD
20'
MIN. REARYARD SETBACK
25'
MAX. LOT COVERAGE
50%
MIN. LIVABLE AREA (EXCLUDING GARAGE)
3,500 SF
FOOTNOTES
1. MIN. LOT FRONTAGE ON CURVES, CUL-DE-SACS, AND KNUCKLES SHALL
BE 25'. MIN LOT FRONTAGE FOR FLAG LOTS SHALL BE 15'.
2. ANY PORTION OF A BASEMENT ABOVE ANY FINISH GRADE IS EXCLUDED
FROM CALCULATION OF BUILDING HEIGHT. BUILDINGS WITHIN 150 FEET OF
A GENERAL PLAN IMAGE CORRIDOR (AVENUE 52, AVENUE 54, AND
MADISON STREET) ARE LIMITED TO 22' WITHIN THE 150-FOOT ZONE.
3. ROLL -UP TYPE GARAGE DOORS ARE REQUIRED.
4. FOR INTERIOR SETBACKS, IF THE BUILDING IS OVER 17' IN HEIGHT, THE
SETBACK IS 5' PLUS 1' FOR EVERY FOOT OVER 17' IN HEIGHT OR
FRACTION THEREOF, TO A MAXIMUM REQUIRED SETBACK OF 10'. THE
ADDITIONAL SETBACK MAY B PROVIDED ENTIRELY AT GRADE LEVEL OR A
COMBINATION OF AT GRADE AND AIRSPACE ABOVE THE 17' BUILDING.
5. DEVELOPER RESERVES THE RIGHT TO CONTROL UNIT TYPE THROUGH
DEVELOPMENT REGULATIONS AND THROUGH APPLICATION TO THE CITY
FOR A CONDITIONAL USE PERMIT FOR SPECIAL PRODUCT TYPES,
INCLUDING ATTACHED OR ZERO LOT LINE RESIDENCES.
BENCH MARK APPROVED BY:
ELEV = 972.241
PD 3 3W
MONUMENT IN HANDWELL AT THE
INTERSECTION OF WASHINGTON ST TIMOTHY R. JONASSON, P.E. DATE
& 42 AVENUE ELEV = 117.05' PUBLIC WORKS DIRECTOR/CITY ENGINEER
R.C.E. NO. 45843 EXP. 12-31-16
ATTACHMENT 3
LINE DATA
NUMBER
BEARING
DISTANCE
L1
S71'41'31 "E
27.31'
L2
S5'04'45"W
116.11'
L3
S69'20'59"E
100.00'
L4
S53'53'43"E
190.37'
L5
S87'46'41 "E
146.58'
L6
S80'46'27"E
246.35'
L7
S73'13'36"E
128.62'
L8
S80'00'57"E
123.56'
L9
N87'26'51 "E
120.42'
L10
N48'52'41"E
318.42'
L11
N23'32'16"W
238.63'
L12
N69'06'17"E
421.56'
L13
S10'56'40"E
87.51'
L14
N59'11'34"E
85.73'
L15
N2'02'35"E
321.34'
L16
S55'21'12"E
85.57'
L17
N25'35'44"W
209.60'
L18
N85'16'32"W
152.69'
L19
S36'56'00"W
246.62'
L20
N85'17'43"W
123.77'
L21
S89'43'00"E
158.76'
L22
N76'08'32"E
169.62'
L23
S62'24'41 "W
188.46'
L24
N55'25'16"E
77.26'
L25
S52'31'35"E
48.45'
L26
S87'00'53"E
211.89'
L27
S78'10'20"E
269.73'
L28
N80'18'49"W
142.15'
L29
S86'47'19"W
157.44'
L30
S82'13'23"E
133.44'
L31
N42'10'27"W
85.00'
L32
N10*17'13"W
85.00'
L33
N14'10'54"E
85.00'
L34
N19'51'47"E
85.00'
L35
N51'17'19"E
85.00'
L36
N73'24'25"E
114.25'
L37
N15*54'56"E
105.94'
L38
N14'47'05"W
93.71'
L39
N35'43'09"W
162.57'
L40
N27'03'38"W
132.17'
L41
S11 °27'23"E
259.32'
L42
SO°21'31 "W
135.48'
L43
SO'08'25"E
257.66'
L44
S12'03'08"W
184.17'
L45
S58'25'30"W
283.49'
L46
S3'50'44"W
130.90'
L47
N22'57'38"E
32.64'
L48
N68'30'56"W
152.86'
L49
N60'51'42"E
48.00'
L50
S79'14'12"W
91.38'
L51
S1'57'02"W
225.49'
L52
N8'54'15"E
81.45'
L53
N16'45'37"W
53.21'
L54
S76'12'16"E
97.76'
L55
N25'50'55"E
61.32'
L56
S23'56'55"E
113.88'
L57
S52'43'13"E
96.40'
L58
N75'54'49"E
63.08'
L59
N28'56'43"E
170.97'
L60
N22'07'57"E
680.44'
LINE DATA
NUMBER
BEARING
DISTANCE
L61
NO'56'51 "E
30.22'
L62
N37'11'20"E
237.44'
L63
N34'17'10"W
99.02'
L64
S79'39'24"W
229.54'
L65
S37'51'29"W
43.04'
L66
N61'29'58"W
231.19'
L67
N53'44'51 "E
178.84'
L68
NO'54'04"E
75.97'
L69
S22'16'10"E
78.28'
L70
N32'45'40"E
440,97'
L71
S32'25'53"W
151.56'
L72
N1 *17'18"W
156.39'
L73
S10*10'09"W
151.13'
L74
S25'01'58"W
261.51'
L75
S35'57'51 "E
107.91'
L76
N83'49'32"E
229.36'
L77
N78'26'41 "E
288,66'
L78
S84'09'47"E
243.67'
L79
S16'22'55"E
89.67'
L80
N30'58'48"E
81.46'
L81
S26'02'29"W
179.22'
L82
S6'32'10"W
224.70'
L83
S5'47'32"W
150.55'
L84
S7'43'15"W
150.96'
L85
S11'06'53"W
110.23'
L86
S8'44'47"W
349.55'
L87
S1037'41 "E
155.34'
L88
S33'44'42"E
159.26'
L89
N41'09'47"W
167.46'
L90
N13'34'45"W
131.81'
L91
S11'04'01"E
273.16'
L92
S58'33'23"E
195.35'
CURVE DATA
NUMBER
DELTA
LENGTH
RADIUS
C1
10*41'44"
39.95'
214.00'
C2
43'24'00"
254.51'
336.00'
C3
29'34'38"
226.62'
439.00'
C4
85*10'43"
37.17'
25.00'
C5
6'57'15"
28.89'
238.00'
C6
1938'40"
81.60'
238.00'
C7
28°39'32"
50.02'
100.00'
C8
69'36'40"
51.03'
42.00'
C9
13'57'44"
218.34'
896.00'
C10
82'03'32"
35.80'
25.00'
C11
24'48'42"
198.77'
459.00'
C12
19'20'41"
154.97'
459.00'
C13
29*45'12"
356.24'
686.00'
C14
5'17'43"
84.47'
914.00'
C15
34*08'10"
59.58'
100.00'
C16
78'24'41"
57.48'
42.00'
C17
4'07'43"
145.12'
2014.00'
C18
87*10'45"
38.04'
25.00'
SHEETINDEX
SHEET NO. DESCRIPTION
1 TITLE, VICINITY, AND LOCATION MAPS
2 TENTATIVE PARCEL MAP
IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA DRAWING NAME:
TENTATIVE PARCEL MAP NO. 36855 TPM 36855 01 TL
PROJECT No.
BEING A SUBDIVISION OF LOTS 78 & 79 OF TRACT NO. 33076-2 0003 MDC
AND LOT T" OF TRACT NO. 33076-1
INDEX SHEET SHEET 1 OF 2
(PAD = 977.1) 1F�1481 11Ti. nnTjV8-� �`o�� 8 0�
\ \ / / (PAD = 976.4) / N1111 .-81117a �� o
/ (PAD = 975.9) / \
p \__
0 TJ-r i E WX _ T METER, PER, / / _rF11AC_S IN it 110 8- /
`� \'PHASE 2 WA
PLAN /
PAD = 74. ( 9 5) (TYP.) / / / �`Oh�M1 �8
p Tj_r 4 v
EXPER ASEERPLAR/ (PAD = 975.7)
EX ELECTRICAL
/ \ 974. - -- Q TRANSFORMER (TYP.) pp 9 \ OP / SEWER LATERZ _rF11A V r 1\10. nn TJTJ 8_2
PE SE 2 SEWER----- \ \
/ \
PLAN (TYP/ ` \ / i \S 4S 4p.. R,o \ \ ° �
p,
,/
1p4 3gpEL / — \
(975) �� ----EX ctEAL / / (PAD - 975.2) v
_
44 p �j
Q j /
Q'i v EX PHASE-2, R, S WATER /
(PAD = 972.5) , / / � ��\ v �4>0o?o3�po �\ PEA W ER PLAN (PAD = 974.7) /
�� PROPOSED � v ,EX SEWER � (41
(N68'30' W) - AREA TO BE GRADED WATER METER LLATERAL PAR,
/ 2.8 ') - DURING FINAL (TYP.) v v ASE2 SEWER,,,
IMPROVEMENTS PLA TYP-.-), ��7 a a a �a-:2
,0 03 \ EX SEWER LATERAL PER \
o� PHASE 2 SEWER PLAN _
EOP
�9 EX ELECTRICAL \
V �/ / ��J I SERVICE v� \ 4�� �\ EEC PHASE 2 STORM DRAIN / / (PAD = 974.3)
-� _
p ' � ,9
/ 9)�� - -� I���� �°y r �MEJ. ' ITJ 8-2 PROPOSED PAD `35pS, PER STORM DRAIN PLAN
(-9� -- \ e e �9� LIMIT JTYP.) v ��7A �o v A /
/ of �o���� nn��/ PROPOSEDSTORM
(TYP.) v �6 70a ,
1 / /
r 7 � /
_ I PROPOSED v
\ / I (PAD - 976.4) II3 SEWER LATERAL �� �9> \ \ // \ a �'-:2
/ / / ('9 o r N i- \\ �) �9 � X EOP
(96 N 0)00 N z Z
A \ \ \
PAD - 974.0
o o (960) / �� PAD - 976.5 II
g5S> PAD = 22,490 SF I - \� ,� 971.8
2 PAD 975.9 \ EOP r -
6i LIMITEX ADTYP. - _ �� �� r- --
�� / ��,� (TYP.) AD = 976.0 PAD 13, 850 S F a, ��
� � �n o \ \°?92 86 _ _ � i EX FH PER PHASE 2
PA = 22, 360 S F �. v p 13.. RWATR PLAN (TYP.)
1 00
00,
(N54'13'33"E)
(135.67') EX PROPERTY,
/ I LINE LIMIT (TYP.) (976)
EX PROPERTY a �a \
/ LINE (TYP.) FI��� 10. a'�
/ N1 .. 1- '8 1Y71
Ln 7 V8 ` \ PHASE�STORM DRMN \
(PAD - 975.96 PER STORM DRAIN
EX PAD
/ LIMIT (TYP.) /
P
\/ O
(N1'04'20" E
(9�o)2J
i96968J �z 4;�a b/
it
�962
------------------
- --_ ---
i—
(9s�
(9So J
PIKE PLACE -
(PRIVATE STREET)
R/W 28' R/W
14' 14' 22'
PUE & IID EASEMENT
I � I
18" REINFORCED 18" REINFORCED 12'
SHOULDER SHOULDER LANDSCAPE
& DRAINAGE MW 2.0%
EASEMENT )C
EX LAKE EDGE /
2-0/62.Oq O
3
3.0" A.C. OVER SLOPES
EXISTING / \
DECORATIVE DECORATIVE DRAINAGE SWALE GRAPHIC SCALE
PAVING 4.5" CRUSHED A.B. PAVING LAKE EDGE
30 0 15 30 60
SECTION A -A'
( IN FEET)
t 233'
PROPOSED PAD = 976.5
EXISTING LAKE "I"
(NORMAL W.S.E. = 947.0)
(100 YR W.S.E. = 956.1)
N.T.S. 1 inch = 30 ft.
00
0
24422 Avenida De La Carlota.
Suite 300
P .E. C46559 Laguna Hills, Ca. 92653
SIGNATURE Phone: 949.453.0111
EXP. 6-30-15 Fax: 949.453.0411
O'Co n s u to n ts, Inc.
STAMP
��pROFESS/O,yq�
��� PAD L �'� Fyc�
� �� ���,
NO. C46559 7 A
EXP. 6-30-15
sq'� Cjv\_ P
BASIS OF BEARINGS
BENCH MARK
APPROVED BY:
IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA
DRAWING NAME:
TPM 36855 02
THE NORTH LINE OF THE NW 1/4
OF SECTION 9, TOWNSHIP 6
SOUTH, RANGE 7 EAST, SAN
BERNARDINO MERIDIAN PER PM
44/67-68 SAID LINE BEARS
N89°46'12"E
ELEV = 972.241
PD 3 3w
MONUMENT IN HANDWELL AT THE
INTERSECTION OF WASHINGTON ST
& 42 AVENUE ELEV = 117.05'
TENTATIVE PARCEL MAP NO. 36855
BEING A SUBDIVISION OF LOTS 78 & 79 OF TRACT NO. 33076-2
AND LOT "P" OF TRACT NO. 33076-1
TENTATIVE PARCEL MAP
PROJECT No.
0003 MDC
TIMOTHY R. JONASSON, P.E. DATE
PUBLIC WORKS DIRECTOR/CITY ENGINEER
R.C.E. NO. 45843 EXP. 12-31-16
SHEET 2 OF 2
�I
DESIGNED BY:R.T.
CHECKED BY: J.R.
SCALE:
1" = 30'
FILE No.
0502
REVISIONS
DATE
NO.DRAWN
BY: R.T.