BRES2018-040878-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type/Subtype:
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
`&ht 44 Qu&rw
DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED
BRES2018-0408
77620 CALLE SONORA
773223022
STEMMER / 1,710SF DWELLING
$111,198.60
Applicant:
JOE W STEMMER JR PD
42215 WASH INGTON ST#355
PALM DESERT, CA 92211
JAN 2 12020
I
CITY OF LA QUINTA
DESIGN & DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
(commencing with Section 70001 of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: B License No.: Fr49172 A
Date: (— ZT' Z(✓ Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 1/21/2020
Owner:
BRIAN STEMMER
77620 CALLE SONORA
LA QUINTA, CA 92253
Contractor:
BRIAN K STEMMER CONSTRUCTION
74478 HWY 111
# 322
PALM DESERT, CA 92260
(760)819-5476
Llc. No.: 649172
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of a work for which this permit is issued.
7,� I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 9211726
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: Applicant:_��GdV''
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building OFficial for a permit subject to
the conditions and restrictions set forth on this applicatio.
1. Each person upon whose behalf this application is made, ,
h person at whose
request and for whose benefit work is performed under.,. r ar:
ant to any permit issued
as a result of this application , the owner, and the applic:,: , ez h agrees to, and shall
defend, indemnify and hold harmless the City of La Quint
`icers, agents, and
employees for any act or omission related to the vork I
firmed under or
following issuance ofthis permit.
2. Any permit issuedas a result of this applicat: • bec
and void if work is not
commenced within 280 days from date of issuan( As
r, or cessation of work
for 180 days vpi!IQJ4&.ct permit to cancellation.
I certify thzt I have rea d this application and `at „e information is correct.
agree to comply with all city and county or. :I, ano btate laws relating to building
construction, and herr by authorize representatives of this city to enter upon the above -
mentioned property r r inspection purposes. A
Date: 1 _ 2 1 ` ZU Signatu, _ ipplicant or Agent)
Date: 1/21/2020
Application Number:
BRES2018-0408
Property Address:
77620 CALLE SONORA
APN:
773223022
Application Description:
STEMMER / 1,710SF DWELLING
Property Zoning:
Application Valuation:
$111,198.60
Applicant:
JOE W STEMMER JR
42215 WASHINGTON ST #355
PALM DESERT, CA 92211
Owner:
BRIAN STEMMER
77620 CALLE SONORA
LA QUINTA, CA 92253
Contractor:
BRIAN K STEMMER CONSTRUCTION
74478 H W Y 111
# 322
PALM DESERT, CA 92260
(760)819-5476
Llc. No.: 649172
--------------------------------------------------------------------------------------------
Detail: 1,710 SF DWELLING - THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODES.
DESCRIPTION ACCOUNT CITY AMOUNT
RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$14.46
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $14.46
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($750.00)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SINGLE FAMILY DETACHED 2018 UPDATE
224-0000-20320
0
$750.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SINGLE FAMILY DETACHED 2018 UPDATE
224-0000-20320
0
$1,560.00
Total Paid for TUMF - RESIDENTIAL: $1,560.00
-- c.; kP?.1 of rb,•zii.Sliii l' —
PERMIT S2ort — 0� —
PLAN LOCATION:
Project Address: 77626 Calle Sonora
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #: 773223022
new SFR
Applicant Name: Joe W. Stemmer Jr. Construction, INC
Address: 42215 Washington St, #355
City, ST, Zip: Palm Desert, CA 92211
Telephone: 760-880-3525
Email: jstemmer@dc.rr.com
Valuation of Project $ 200,000.
Contractor Name: Joe W. Stemmer Jr. Construction, INC
New SFD Construction:
Address:42215 Washington St, #355
Conditioned Space 1710 SF
City, St, Zip Palm Desert, CA 92211
Garage 492 SF
Telephone: 760-880-3525
Patio/Porch SF
Email:jstemmer@dc.rr.com
Fire Sprinklers 2202 SF
State Lie: B605857 City Bus Lic:763387
Arch/Eng Name: GLS Design
Construction Type: Frame Occupancy: SFR
Address:74991 Joni Dr. #9
Grading:
City, St, zip Palm Desert, CA 92260
Telephone: 760-340-3528
Bedrooms:4
Stories: l
# Lnits: l
Email: l5 isarchitecture.Com
State Lie: C11991 City Bus Lie:
Property Owner's Name:
New Commercial / Tenant Improvements:
.Address:
Total Building SF
City, ST, Zip
Construction Type: Occupancy:
Telephone:
Email:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
0aiKrau
—<IF-M nof,h,UFM-Rl' —
PERMIT #to
PLAN LOCATION:
Project Address77r« cilo.,
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN#: '�-7 � ` ?,1 3- 0Z2-
Qtli0.t�tI
Applicant Name: ?j( cv\
'� Z Z-
Address: -1 Lt L4 7ri� Rut
bb
City, ST, Zip: IPM 6 ,
Telephone: -7 l
Email: I_ (/C�-� b �I.I
Valuation of Project $
Contractor Name:
New SFD Construction:
Address:
Conditioned Space SF
City, St, Zip
Garage SF
Telephone:
Patio/Porch SF
Email:
Fire Sprinklers SF
State Lie: City Bus Lie:
Arch/Eng Name: A Construction Type:
Address: l ( �. Cs' rdC- Oln r Q VC Grading:
City, St, Zip 124I w, 1`3-cs-e q Z ZL,
Telephone: -7('6 4S I � S 2 Bedrooms: Stories
Email:
State Lie:
City Bus Lie:
Occupancy:
# Units:
Property Owner's Name: l t ary �
New Commercial / Tenant Improvements:
Address: - (� �
Total Building SF
City, ST, Zip
Construction Type: Occupancy:
Telephone:
{��
Email:
78495 CALLE TAMPICO
LA QU I NTA, CA 92253
760-777-7000
CERTIFICATE OF COMPLIANCE40
Desert Sands Unified School District
47950 Dune Palms Road
DESERT
SANDS
La Quinta, CA 92253
Date:
UNIFIED
(760)771-8515
No.: 20-015801588-1
SCHOOL
DISTRICT
Owner: Joe Stemmer Jr Email:
Address: 77620 Calle Sonora Jurisdiction: La Quinta
City: La Quinta Tract #:
Type: Single Family Residential
Lot # Street No. Street Name Sq. Feet APN Permit No.
77620 Calle Sonora 1710 773-223-022
RECEIVED
JAN 17 2020
CITY OF LA QUINTA
Comments: DESIGN AND DEVELOPMENT DEPARTMENT
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fess imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $3.79 X 1710 S.F. or $6,480.90 have been paid for the property listed above and that building
permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid By: cc/lst Sank j Brjan Stemmer.
Bank Name/Recipient of Certificate
By Scott L. Bailey
Superintendent
Fee Collected/ Exempted by: Rodney Slagle
av� 4��w
Check No.: 1693281
Telephone:
Funding: Residential
Certificate Fees Due: $6,480.90
Original Payment(3) Rec'd: $0.00
New Payment Ree'd: $6,480.90
Over/Under: $0.00
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) orto another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
X. Building Permit Number: 040
�--�� Project Description: SFR
Exempt: o
(Materials may contain hazardous wastes and
'�Y• I are not subject to recycling provisions)
Construction Debris Management Plan
Plan Submittal Date
Job Site Address
Owner's Name
Number, Street, or PO Box
City, State, Postal Code
Owner's Phone Number
77-620 Calle Sonora La Quinta, Ca. 92253
Brian Stemmer
Project Manager's
Project Manager's Phone N
Project Manager's E-mail Ai
Builder / Contn
Number, Street or PO
City, State, Postal (
Owner
Owner
Project Square Footage 1,715
City Approval By fK j Y Z'Q
Date of City Approval
Materials To Be Discarded:
Product
Tons
Trash
6.35 Not recyclable
Product
Tons
Asphalt
0.00 Recyclable
Masonry (broken)
0.00 Recyclable
Brick/Block
0.10 Recyclable
Plaster
2.15 Recyclable
Cardboard
0.40 Recyclable
Scrap Metal
0.00 Recyclable
Commingled
0.20 Recyclable
Tile (floor)
_
0.19 Recyclable
Concrete
8.58 Recyclable
Tile (roof)
_
0.25 Recyclable
Drywall
0.90 Recyclable
Wood
3.25 Recyclable
Donated /Reuse*
0.00 Recyclable
Landscape Debris
0.10 Recyclable
*Describe Items
new construction materials
Totals: Recycle Trash Projected Diversion:
16.111 6.4 L1. 44%
I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsite waste is diverted
from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials
generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued
in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A
contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the
property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The
property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If self -
hauling, all refuse material from this project site must be taken to an approved recycler or transfer station.
12
w
cm
O
CV
r`
Z
t
w
a
a
a
a
a�
z
Joe W. Stemmer Construction
42215 Washington St.
Palm Desert, CA 92211
(760) 819-5476
January 4, 2020
City of La Quinta
Attention: Building Department
Subject: Change of ownership
To Whom It May Concern:
This letter is regarding the vacant lot located at 77-620 Calle Sonora, APN 773-223-022.
I release all the SFD plans and documents to Brian Stemmer. A grant deed has been
recorded showing the transfer of the above stated address.
Rasp °ctFul ubmitted,
�2'e
W. St me
RECEIVED
_IAN 17 2020
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
STEMMER RESIDENCE
77620 CALLE SONORA
LA Q U I NTA, CA 92253
Project Designer:
GLS ARCHITECTURE GRO
74991 JONI DR #9
PALM DESERT, CA 9 ;
760 3403528
Report Prepared
Armando Chavez
UP INC. o-*'F1 cE
CITY OF LA QUINTA
?60 BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE Io 3Lk101 BY i,-AnLAdR-
'T3Q�2oIg- 1)1108
44890 SEELEY
LA Q U I NTA, CA 92253
760 278.1840
Job Number:
2018-GLS-017
Date:
12/13/2018
FZV.CENED
V0 012019 C2
INTERWes"
CONSUtjtNG CROUP
JAN 3 0 2019
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
WIt
5e- ;W0
TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF-1 R-PRF-01-E Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 11
Form MF-1 R Mandatory Measures Summary 12
HVAC System Heating and Cooling Loads Summary 16
`EnergyPro 7.1 by EnergySoft Job Number: ID: 2018-GLS-017 User Number: 20648 1
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SONORA RESIDENCE Calculation Date/Time: 11:16, Thu, Dec 13, 2018
Calculation Description: Title 24 Analysis
Input File Name: 102 - 77620 CALLE SONORA.ribd16x
CF1 R-PRF-01
Page 1 of I
GENERAL INFORMATION
01
Project Name
SONORA RESIDENCE
02
Calculation Description
Title 24 Analysis
03
Project Location
77620 CALLE SONORA
04
City
LA QUINTA
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
09
Software Version
CBECC-Res 2016.3.1 (1019)
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
0
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ftZ)
1710
15
Number of Zones
1
16
Slab Area (ftZ)
1710
17
Number of Stories
1
18
Addition Cond. Floor Area(ft2)
n/a
n/a
19
21
Natural Gas Available
Glazing Percentage (%)
Yes
17.0%
20
Addition Slab Area (ft)
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider,
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
I 07
08
Energy Use (kTDV/ftZ-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
0.30
2.23
-1.93
-643.3%
Space Cooling
89.89
80.43
9.46
10.5%
IAQ Ventilation
1.27
1.27
0.00
0.0%
Water Heating
7.35
12.03
-4.68
-63.7%
Photovoltaic Offset
---
0.00
0.00
----
Compliance Energy Total
98.81
95.96
2.85
2.9%
Registration Number: 218-P010328974A-000-000-0000000-0000 Registration Date/Time: 2018-12-13 11:24:47 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-13 11:17:03
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SONORA RESIDENCE Calculation Date/Time: 11:16, Thu, Dec 13, 2018
Calculation Description: Title 24 Analysis
Input File Name: 102 - 77620 CALLE SONORA.ribd16x
CFI R-PRF-01
Page 2 of v
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency
EDR of Proposed Efficiency EDR Value of Proposed PV + Battery
Final Proposed EDR
55.1
54.0 0.0
54.0
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV)
renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified. i
Notes:
• PV generation will be capped @ proposed design electric use (no battery)
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Raised heel truss
• Cool roof
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
-- None --
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
SONORA RESIDENCE
1710
1
3
1
0
1
Registration Number: 218-P010328974A-000-000-0000000-0000 Registration Date/Time: 2018-12-13 11:24:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-13 11:17:03
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SONORA RESIDENCE Calculation Date/Time: 11:16, Thu, Dec 13, 2018
Calculation Description: Title 24 Analysis
Input File Name: 102 - 77620 CALLE SONORA.ribd16x
CF1 R-PRF-01
Page 3 of 9
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Z1
Conditioned
HVAC-Z11
1710
10
DHW Sys 1
n/a
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door Area (ft)
Tilt (deg)
493 - N
Z1
R-15 Wall+ 1 EPS
0
Front
493
78
90
E-350
Z1
I R-15 Wall+ 1 EPS
90
Left
350
144
90
493 - S
Z1
I R-15 Wall+ 1 EPS
180
Back
493
92.6
90
W-350
Z1
R-15 Wall+ 1 EPS
270
Right
350
21.3
90
1710
Z1
R-38 Roof
n/a
n/a
1710
n/a
n/a
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Z1
Attic RoofZ1
Ventilated
0.2
0.86
0.88
Yes
Yes
Registration Number: 218-P010328974A-000-000-0000000-0000 Registration Date/Time: 2018-12-13 11:24:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-13 11:17:03
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SONORA RESIDENCE Calculation Date/Time: 11:16, Thu, Dec 13, 2018
Calculation Description: Title 24 Analysis
Input File Name: 102 - 77620 CALLE SONORA.ribd16x
CF1 R-PRF-01
Page 4 of S
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
4046
Window
493 - N (Front-0)
-
1
18.0
0.32
0.25
Insect Screen (default)
6050
Window
493 - N (Front-0)
----
-
1
30.0
0.32
0.25
Insect Screen (default)
60502
Window
493 - N (Front-0)
1
30.0
0.32
0.25
Insect Screen (default)
10080
Window
E-350 (Left-90)
-
1
80.0
0.32
0.25
Insect Screen (default)
8080
Window
E-350 (Left-90)
-
--
1
64.0
0.32
0.25
Insect Screen (default)
1416
Window
493 - S (Back-180)
-
1
2.0
0.32
0.25
Insect Screen (default)
14162
Window
493 - S (Back-180)
1
2.0
0.32
0.25
Insect Screen (default)
6080
Window
493 - S (Back-180)
----
---
1
48.0
0.32
0.25
Insect Screen (default)
1656
Window
493 - S (Back-180)
----
-
1
8.3
0.32
0.25
Insect Screen (default)
16562
Window
493 - S (Back-180)
-
1
8.3
0.32
0.25 1
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
3080
493 - S
24.0
1.00
2880
W-350
21.3
1.00
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
R-value
Winter Design
U-factor
Assembly Layers
Attic RoofZ1
Attic Roofs
Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.
none
0.644
• Cavity/Frame: no insul. /2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)
R-38 Roof
Ceilings (below
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C. with Raised Heel
Truss Height 20 in
R 38
0.025
• Inside Finish: Gypsum Board
Cavity/Frame: R-9.1 /2x4
Over Ceiling Joists: R-28.9 insul.
R-15 Wall+ 1 EPS
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.0
R 15
0 064
• Inside Finish: Gypsum Board
• Cavity / Frame: R-15 / 2x4
• Sheathing / Insulation: R4 Sheathing
• Exterior Finish: 3 Coat Stucco
Registration Number: 218-P010328974A-000-000-0000000-0000 Registration Date/Time: 2018-12-13 11:24:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-13 11:17:03
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SONORA RESIDENCE Calculation Date/Time: 11:16, Thu, Dec 13, 2018
Calculation Description: Title 24 Analysis
Input File Name: 102 - 77620 CALLE SONORA.ribd16x
CF1 R-PRF-01
Page 5 of 3
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
17102
Z1
1710
0.1
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1 (1)
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating /
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
NEEA Heat Pump
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
Brand / Model /
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Other
Condition
DHW Heater 1
Gas
Small Storage
1
50
0.62 EF
<= 75 kBtu/hr
R-0/R-0
0
I n/a
n/a
I n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC-Z11
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFurnace
1
80 AFUE
Registration Number: 218-Po10328974A-000-000-0000000-0000 Registration Date/Time: 2018-12-13 11:24:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-13 11:17:03
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SONORA RESIDENCE Calculation Date/Time: 11:16, Thu, Dec 13, 2018
Calculation Description: Title 24 Analysis
Input File Name: 102 - 77620 CALLE SONORA.ribd16x
CF1 R-PRF-01
Page 6 of 8
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Name
System Type
Number of Units
Efficiency
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
PkgAirCond
1
11
14
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Not Required
Not Required
Not Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
5.0
I Not Required
Not Required
Not Required
Not Required
n/a
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
Registration Number: 218-P010328974A-000-000-0000000-0000 Registration Date/Time: 2018-12-13 11:24:47 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-13 11:17:03
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SONORA RESIDENCE Calculation Date/Time: 11:16, Thu, Dec 13, 2018
Calculation Description: Title 24 Analysis
Input File Name: 102 - 77620 CALLE SONORA.ribd16x
CF1R-PRF-01
Page 7 of 8
IAQ (Indoor Air Quality) FANS
01
02
03
04 05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Recovery
IAQ Fan Type Effectiveness(%)
HERS Verification
SFam IAQVentRpt
47
0.25
Default 0
Required
PROJECT NOTES
ALL EXISTING AND PROPOSED INPUT DATA USED IN THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER. ANY ALTERATION OR DEVIATION FROM THIS CALCULATION
WILL BE GENERAL CONTRACTOR RESPONSABILITY.
Registration Number: 218-P010328974A-000-000-0000000-0000 Registration Date/Time: 2018-12-13 11:24:47 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-13 11:17:03
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SONORA RESIDENCE Calculation Date/Time: 11:16, Thu, Dec 13, 2018
Calculation Description: Title 24 Analysis
Input File Name: 102 - 77620 CALLE SONORA.ribd16x
CF1 R-PRF-01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature
ARMANDO CHAVEZ
Company:
Signature Date:
TITLE 24 OF THE DESERT
2018-12-13 11:21:30
Address:
CEA/HERS Certification Identification (If applicable):
74800 Shirley #62
N.A.
City/State/Zip:
Phone:
PALM DESERT, CA 92260
760-278-1840
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature-
Ruben Romero
Company:
Date Signed:
GLS ARCHITECTURE GROUP INC
2018-12-13 11:24:47
Address:
License:
74491 JONI DR SUITE #9
N.A.
City/State/Zip:
Phone:
Palm Desert, CA 92260
760-340-3528
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration
Provider responsibility for the accuracy of the information.
F
Easy to Verify
at CaICERTS.com
Registration Number: 218-Po10329974A-000-000-0000000-0000 Registration Date/Time: 2018-12-13 11:24:47
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149
HERS Provider: CaICERTS inc
Report Generated at: 2018-12-13 11:17:03
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
STEMMER RESIDENCE
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration 11211312018
Date
Project Address
77620 CALLS SONORA LA QUINTA
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
1,710
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features Status
Roof Wood Framed Attic R 38 1,710 Cool Roof New
Slab Unheated Slab -on -Grade - no insulation 1,710 Perim = 0' New
Wall Wood Framed R 15 1,350 Add=R-4.0 New
Door Opaque Door - no insulation 45 New
FENESTRATION I Total Area: 291 Glazing Percentage: 17.0% New/Altered Average U-Factor. a32
Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status
Front (N) 78.0 0.320
Left (E) 144.0 0.320
0.25 none none Bug Screen New
0.25 none none Bug Screen New
Rear (S) 68.6 0.320
0.25 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
HVAC DISTRIBUTION
Location Heating
Packaged Air Condition 14.0 SEER Setback New
Duct
Cooling Duct Location R-Value Status
HVAC-Z1 Ducted Ducted Attic 8.0 New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
1 Small Storage Gas 50
0.62 Standard
New
Ener Pro 7.1 by EneLqySoft User Number. 20648
ID: 2018-GLS-017
Page 11 of 16
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. "Exceptions may apply.
(Original 08/2016]
Building Envelope Measures:
§ 110.6(a)l:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per
NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011."
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
110.E-A and 110.E-B for compliance and must be caulked and/or weatherstri ed.'
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g),
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of 110.8 i when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceilin .'
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or
§ 150.0(c):
less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a
wood framed assembly.*
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0,037 maximum U-factor.'
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 11 0.8.
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
§ 150.0(g)1:
requirement also applies to controlled ventilation crawls ace for buildings complyin2 with the exception to § 150.0(d).
§ 150.0(g)2:
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
insulation in all exterior walls vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58• or the weighted average U-factor of all fenestration must not exceed 0.58."
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150,0(e)l A:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)l B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible operable, and tight -fitting damper or combustion -air control device."
§ 150.0(e)l C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 110,2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110,2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.'
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(p)5.
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
§ 110.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters."
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)l:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using desi n conditions specified in § 150.0(h)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
dryer vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve."
§ 150.00)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150,00)3A;
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)313:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150,0(n)l:
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2;
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation SRCC or by a listing agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110,8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing,that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)l:
(RA3.1.4.3,8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts."
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such toe is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150,0(m)9;
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0 m 11 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure dro , and labeling requirements of § 150.0(m)12.
Aomqbk
�LU 2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy _ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced airs stems."
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation,
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
§ 150.0(o)1A:
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
§ 110.4(a):
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.*
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
§ 110.4(b)1:
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
§ 110.4(b)3:
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
150.0
§ (p)'
rate, p1ping, filters, and valves'
Lighting Measures:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
§ 110.9:
of § 110.9..
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
§ 110.9(e):
be certified to the Energy Commission according to Reference JointA ndix JA8,
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
§ 150.0(k)1 D:
20 kHz.
_
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
§ 150.0(k)1 F.
meet the applicable requirements of § 150.0(k).*
_must
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1 G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)1 H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
§ 150.0(k)2C:
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturers instructions.
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
§ 150.0(k)2E:
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5 ; and meets all other requirements in § 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5( ; and all other requirements in § 150.0(k)2.
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
§ 150.0(k)21:
provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
I
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.'
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS.
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 150.0 k 3A or with the applicable requirements in §§ 110.9, 130.0, 130.2 130.4 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k 3B or 150,0 k 3D must compI with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply with the applicable requirements in §§ 110.9 130.0 130.2 130.4, 140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.1 0b through § 110.10 e .
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.' _
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.*
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone measured in the vertical lane."
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel), and a pathway for routing of plumbing from the solar zone to the water -heating system,
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.1 0c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".