Loading...
BRES2019-035478-495 CALLE TAMPICO T4ht 4 LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: BUILDING RESIDENTIAL/REMODEL Application Number: BRES2019-0354 Property Address: 79705 N TOM FAZIO LN APN: 766032021 Application Description: HAGGERTY / REMODEL THROUGHOUT DWELLING Property Zoning: Application Valuation: $400,000.00 Applicant: D KHA ARCHITECHTS 72182 PAINTER PATH PALM DESERT, CA 92260 JAN 0 7 2020 CITY OF LA QUINTA DESIGN & DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Clas : License No.: 82 Date: , v - Contractor: OWNER -BUILD DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 1/7/2020 Owner: MIKE HAGGERTY Contractor: SANTUCCI BUILDERS INC 72529 BEAVERTAIL STREET PALM DESERT, CA 92260 (760)578-7757 Llc. No.: 820801 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' co pens, tion, as provided for by Section 3700 of the Labor Code, for the performance nF t work for which this permit is issued. Tueo3 have and will maintain workers' compensation insurance, as required by Se0 of theLabor Code, for the performance of the work far which this permit is isworkers' compensation insurance carrier and policy number are; Carrier:/ R15121REMIER INSURANCE COMPANY Policy Number: 7600018977191 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Se n 3700 of he Lahar Code, I shall forthwith comply W hth se provisions. Date: - Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any actor omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to ter upon the above - mentioned If oper4l for inspection purposes. - Date: � Signature (Applicant or Agent): Date: ,1/7/2020 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: KHA ARCH ITECHTS 72182 PAINTER PATH PALM DESERT, CA 92260 BRES2019-0354 79705 N TOM FAZIO LN 766032021 HAGGERTY / REMODEL THROUGHOUT DWELLING $400,000.00 Owner: MIKE HAGGERTY Contractor: SANTUCCI BUILDERS INC 72529 BEAVERTAIL STREET PALM DESERT, CA 92260 (760)578-7757 Llc. No.: 820801 Detail: 1120 SF REMODEL AT MASTER BATH, WET BAR, LIVING ROOM AND, BACK PATIO AREAS, WITH FIREPLACE ADDITION TO GUEST HOUSE [RA ENGINEERING]. THIS INCLUDES FENESTRATION AT ENTRY DOOR AND PATIO SLIDER. CMU WINDSCREEN AND ENTRY PER SEPARATE BUILDING PERMIT. 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $16.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $16.00 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $26.83 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $26.83 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES/FIXTURES, ADDITIONAL 101-0000-42403 0 $67.00 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES/FIXTURES, ADDITIONAL PC 101-0000-42600 0 $16.75 Total Paid for ELECTRICAL 2019: $137.41 DESCRIPTION ACCOUNT CITY AMOUNT FIREPLACE 101-0000-42400 0 $161.00 DESCRIPTION ACCOUNT CITY AMOUNT FIREPLACE PC 101-0000-42600 j 0 $241.50 Total Paid for FIREPLACE 2019: $402.50 DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1 $125.00 Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $53.68 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $53.68 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $13.42 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $26.83 DESCRIPTION ACCOUNT CITY AMOUNT ROOF DRAIN 101-0000-42401 0 $13.42 DESCRIPTION ACCOUNT CITY I AMOUNT ROOF DRAIN PC 101-0000-42600 0 $13.42 Total Paid for PLUMBING 2019: $174.45 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, EA ADDITIONAL 500SF 101-0000-42400 0 $72.45 DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, EA ADDITIONAL 500SF PC 101-0000-42600 0 $57.96 DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, FIRST 100SF 101-0000-42400 0 $54.74 DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, FIRST 100SF PC 101-0000-42600 0 $149.73 Total Paid for REMODEL 2019: $334.88 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $52.00 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $52.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($2.64) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($122.36) DESCRIPTION ACCOUNT CITY AMOUNT DOOR/WINDOW, NEW/ALT, FIRST 1 101-0000-42400 0 $2.64 DESCRIPTION ACCOUNT CITY AMOUNT DOOR/WINDOW, NEW/ALT, FIRST 1 101-0000-42400 0 $104.69 DESCRIPTION ACCOUNT CITY AMOUNT DOOR/WINDOW, NEW/ALT, FIRST 1 PC 101-0000-42600 0 $122.36 Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION 2019: $104.69 DESCRIPTION ACCOUNT CITY AMOUNT ALTERATIONS/ADDITIONS - RESIDENTIAL 101-0000-42400 0 $81.00 Total Paid for ZONING CLEARANCE - PLANNING PLAN CHECK: $81.00 I��r Qwk rePERMIT# RP �(GEM ofrbo DESEERTT-IW PLAN LOCATION: Project Address: 79-705 Tom Fazio Lane North Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: 766-032-021 • TWO NEW EXTERIOR FIREPLACES —• REPAINT EXISTING EXTERIOR STUCCO • NEW ENTRY GATE / REMOVE EXISTING ENTRY GATE STRUCTURE —• REPLACE ENTRY DOOR & SIDELIGHTS IN EXISTING OPENINGS Applicant Name: KHAArchitects • REPLACE POCKET SLIDING DOOR TO OUTDOOR LIVING SPACE _• FRONT COURTYARD WALL MATERIAL CHANGE • ROOF EXTENSION OVER OUTDOOR LIVING • REPLACE EXISTING INTERIOR FIREPLACES . UPDATE UPDATE FLOORING FINISHES THROUGHOUT Address: 72-185 Painters Path City, ST, Zip: Palm Desert, CA 92260 • NEW MASTER BATH VANITIES & TUB —• RENOVATE WET BAR AREA Telephone: (760) 776-4068 • CONVERT EXISTING PANTRY TO WINE STORAGE Email: dave@kristihanson.com Valuation of Project $ 400,000 Contractor Name: SANTUCCI BUILDERS INC New SFD Construction: Address: 72529 BEAVERTAIL ST Conditioned Space SF City, St, Zip PALM DESERT, CA92260 Garage SF Telephone: (760) 578-7757 Patio/Porch SF Email: Fire Sprinklers SF State Lic: City Bus Lic: Arch/Eng Name: RA STRUCTURAL ENGINEERING Construction Type: VB Occupancy: R-3 Address: 77570 SPRINGFIELD LN Grading: City, St, Zip PALM DESERT, CA 92211 Bedrooms: Stories: # Units: Telephone: (760) 360-9998 Email: john@rastructural.com State Lic: City Bus Lic: Property Owner's Name: Mike Haggerty Address: City, ST, Zip Telephone: ( Email: New Commercial / Tenant Improvements: Total Building SF Construction Type: Occupancy: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 Date: 1/6/2020 No.: 20-01583-1 Owner: Mike Haggerty Address: 79705 N. Tom Fazio Lane City: La Quinta Type: Residential Addition < 500 Sq ft Lot # Street No. 79705 Comments: CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760)771-8515 Street Name N. Tom Fazio Lane Email: Jurisdiction: La Quinta Tract #: Sq. Feet APN 16 766-032-021 DESERT SANDS UNIFIED SCHOOL DISTRICT Permit No. RECEIVED JAN 0 7 2020 CITY OF LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less Exempt This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 16 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: Exempt / Jerry Santucci Bank Name/Recipient of Certificate By Scott L. Bailey Superintendent Fee Collected/ Exempted by: Rodney Slagle Check No.: Telephone: Funding: Exempt Certificate Fees Due: $0.00 Original Payment(s) Rec'd: $0.00 New Payment Rec'd: $0.00 Over/Under: $0.00 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. Pel essionally Marra ed 6y THE QUARRY AT LA QUINTA PSUNAL . ED HOMEOWNERS ASSOCIATION ®PROPERTY MANAGEMENT 1710 0WAI-11a valley's CV111mm"k). Alrrrangernr!ut rnrrryxtn� August 23, 2019 Mike & Olga Haggerty 79705 Fazio Lane North La Quinta, CA 92253 Re: 79-705 Tom Fazio Lane Noth - Remodel Dear Mr. & Mrs. Haggerty: 68950 Adelina Road Cathedral City, CA 92234 Phone: (760) 325-9500 Fax: (760) 325-9300 The Board of Directors and Architectural/Landscape Committee appreciate your recent submission of plans for the remodel. We thank you for your patience during the review process to ensure the HOA's Architectural Guidelines are being followed. The Architectural Committee and Board of Directors have approved the plans pending the $$500 review/application fee and $2500 refundable deposit. (please make payable to the Quarry HOA) Thanking you in advance for your assistance in this matter and all the best to you in your exciting endeavor. Sincerely, Caren OCiva Caren Oliva Community Manager, The Quarry at La Quinta HOA Personalized Property Management cc: Board of Directors, File. RECEIVED OCT 3 0 2019 CITY OF LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT V CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Hagerty Remodel Calculation Date/Time: 08:26, Thu, Sep 26, 2019 Calculation Description: Title 24 Analysis Input File Name: Haggerty Remodel.ribd16x CF1 R-PRF-01 Page 1 of 14 GENERAL INFORMATION 01 Project Name Hagerty Remodel 02 Calculation Description Title 24 Analysis 03 Project Location 79-705 Tom Fazio Lane 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 45 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ftZ) 5108 15 Number of Zones 4 16 Slab Area (ft) 5108 CITI( OF LA (JU111 i A k Number of Stories 1 18 Addition Cond. Floor Area (ft) 0 BUIL®INU L ICJ 04 1 Natural Gas Available Yes 20 Addition Slab Area (ftZ) 0 t Glazing Percentage (%) 29.0% `h r 1 0 COMPLIANCE RESULTS p�,PLIANCc ' E D 01 Building Complies with Computer Performan e .1 j 02 This building DOES NOT require HERS Verifi t1 7►TE _ _— -- DEC 0 2019 03 This building incorporates one or more Special Features shown below L.11 i Ur LA YU111IN ENERGY USE SUMMARY U01UN AIYU UCVCLUrIvI0I UCt'HKIMCK1 04 05 06 07 08 Energy Use (kTDV/ftZ-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 7.61 8.28 I -0.67 -8.8% Space Cooling 176.80 173.23 3.57 2.0% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 8.23 8.23 0.00 0.0% Photovoltaic Offset -- 0.00 0.00 .... Compliance Energy Total 192.64 189.74 2.90 1.5% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins Registration Number: 419-P010105534A-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 09/26/2019 08:46 Report Version - CF1 R-06232018-1149 k HERS Provider: CHEERS Report Generated at: 2019-09-26 08:27:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Hagerty Remodel Calculation Date/Time: 08:26, Thu, Sep 26, 2019 Calculation Description: Title 24 Analysis HERS FEATURE SUMMARY Input File Name: Haggerty Remodel.ribd16x CF1 R-PRF-01 Page 2 of 14 The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: --None-- Cooling System Verifications: --None -- HVAC Distribution System Verifications: • Duct Sealing required if a duct system component, plenum, or air handling unit is altered Domestic Hot Water System Verifications: - None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ftZ) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Hagerty Remodel 5108 1 3 4 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ftZ) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 1 Conditioned HVAC System 11 1437 8 DHW Sys 1 n/a Zone 2 Conditioned HVAC System 22 1450 8 DHW Sys 1 n/a Zone 3 Conditioned HVAC System 23 1276 8 DHW Sys 1 n/a Zone 4 Conditioned HVAC System 44 945 8 DHW Sys 1 n/a Registration Number: 419-P010105534A-000-000-0000000-0000 Registration DateMme: 09/26/2019 08:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:27:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Hagerty Remodel Calculation Date/Time: 08:26, Thu, Sep 26, 2019 CF1 R-PRF-01 Page 3 of 14 Calculation Description: Title 24 Analysis Input File Name: Haggerty Remodel.ribd16x OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Gross Area (ftZ) Window & Door Area (ftZ) Tilt (deg) Wall Exception Status Verified Existing Condition Northeast Exterior Wall Zone 1 R-21 Wall 45 Front 260 108 90 n/a Existing No Southeast Exterior Wall Zone 1 R-21 Wall 135 Left 252 99.012 90 n/a Existing No Southwest Exterior Wall Zone 1 R-21 Wall 225 Back 760 285.99 90 n/a Existing No Northwest Exterior Wall Zone 1 R-21 Wall 315 Right 430 90 90 n/a Existing No Notheast Interior Surface Zone 1 —Zone 2 R-21 Wall1 122 0 n/a Existing No Southeast Interior Surfac Zone 1 —Zone 2 R-21 Wall1 120 0 n/a Existing No Roof 3 Zone 1 R-38 Roof Attic 1437 n/a Existing No Notheast Exterior Wall Zone 2 R-21 Wall 45 Front 364 124.992 90 n/a Existing No Southwest Exterior Wall 2 I Zone 2 R-21 Wall 225 Back 388 193.05 90 n/a Existing No Northwest Exterior Wall 2 Zone 2 R-21 Wall 315 Right 170 81 90 n/a Existing No Northeast Interior Surfac Zone 2»Zone 4 R-21 Wall1 192 0 n/a Existing No Southeast Interior Surfac 2 Zone 2»Zone 3 R-21 Wall1 122 0 n/a Existing No Southwest Interior Surfac Zone 2»Zone 1 R-21 Wall1 1220 I 0 n/a Existing No Northwest Interior Surfac Zone 2»Zone 4 R-21 Wall1 108 0 n/a Existing No Roof 4 Zone 2 R-38 Roof Attic 1450 n/a Existing No Northeast Exterior Wall 2 Zone 3 R-21 Wall 45 Front 480 82 90 n/a Existing No Southeast Exterior Wall 2 Zone 3 R-21 Wall 135 Left 1092 92 90 n/a Existing No Southwest Exterior Wall 3 Zone 3 R-21 Wall 225 Back 455 162 90 n/a Existing No Northwest Exterior Wall 3 Zone 3 R-21 Wall 315 Right 770 62.5 90 n/a Existing No Northwest Interior Surfac 2 Zone 3»Zone 2 R-21 Wall1 378 0 n/a Existing No Roof 5 Zone 3 R-38 Roof Attic 1264 n/a Existing No Northeast Exterior Wall 3 Zone 4 R-21 Wall 45 Front 602 24 90 n/a Existing No Southeast Exterior Wall 3 Zone 4 R-21 Wall 135 Left 394 24.5895 90 n/a Existing No Southwest Exterior Wall 4 Zone 4 R-21 Wall 135 Left 364 65.5 90 n/a Existing No Northwest Exterior Wall 4 Zone 4 R-21 Wall 315 Right 250 17.5 90 n/a Existing No Southeast Interior Surfac 3 Zone 4»Zone 2 R-21 Wall1 140 0 n/a Existing No Southwest Interior Surfac 2 Zone 4»Zone 2 R-21 Wall1 230 0 n/a Existing No Roof 6 Zone 4 R-38 Roof Attic 939 n/a Existing No Registration Number: 419-P010105534A-000-000-0000000-0000 Registration Datefl-ime: 09/26/2019 08:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:27:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Hagerty Remodel Calculation Date/Time: 08:26, Thu, Sep 26, 2019 CF1 R-PRF-01 Page 4 of 14 Calculation Description: Title 24 Analysis Input File Name: Haggerty Remodel.ribd16x OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 12 Name Zone Type Orientation Area (ft2) Skylight Area (f:2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Status Verified Existing Condifion Roof Zone 3 R-38 Roof Attic1 - specify - 12.1 12 4 0.1 0.85 No Existing No Roof 2 Zone 4 R-38 Roof Attic1 - specify - 6.1 6 4 0.1 I 0.85 No Existing No ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Zone 1 Attic RoofZone 1 Ventilated 4 0.1 0.85 Yes No Existing No Attic Zone 2 Attic RoofZone 2 Ventilated 4 0.1 0.85 Yes No Existing No Attic Zone 3 Attic RoofZone 3 Ventilated 4 0.1 0.85 Yes No Existing No Attic Zone 4 Attic RoofZone 4 Ventilated 4 0.1 0.85 Yes No Existing No Registration Number: 419-P010105534A-000-000-0000000-0000 Registration Date/Time: 09/26/2019 08:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:27:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Hagerty Remodel Calculation Date/Time: 08:26, Thu, Sep 26, 2019 Calculation Description: Title 24 Analysis Input File Name: Haggerty Remodel.ribd16x CF1 R-PRF-01 Page 5 of 14 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 Verified Existing Name Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading Status Condition Window H2 Northeast Exterior Wall (Front-45) 12.0 9.0 1 108.0 0.65 0.43 Insect Screen (default) Existing No Window G2 Southeast Exterior Wall (Left-135) 6.0 9.0 1 54.0 0.65 0.43 Insect Screen (default) Existing No Window 15 Southeast Exterior Wall (Left-135) 5.1 5.0 0.824 21.0 1.19 0.43 Insect Screen (default) Existing No Window H1 Southwest Exterior Wall 12.0 9.0 1 108.0 0.65 0.43 Insect Screen (default) Existing No (Back-225) Window 16 Southwest Exterior Wall 5.1 5.0 1.02 26.0 1.19 0.43 Insect Screen (default) Existing No (Back-225) Window 17 Southwest Exterior Wall 4.0 5.0 1 20.0 0.59 0.57 Insect Screen (default) Existing No (Back-225) Window 18 Southwest Exterior Wall 5.0 9.0 1 45.0 0.59 0.57 Insect Screen (default) ! Existing No (Back-225) Window 19 Southwest Exterior Wall 5.0 9.0 1 45.0 0.59 0.57 Insect Screen (default) Existing No (Back-225) Window 21 Southwest Exterior Wall 6.9 6.0 1 014 42.0 1.19 0.43 Insect Screen (default) Existing No (Back-225) Window 20 Northwest Exterior Wall 6.0 9.0 1 54.0 1.19 0.43 Insect Screen (default) Existing No (Right-315) Window 22 Northwest Exterior Wall 2.5 6.0 1 15.0 0.59 0.57 Insect Screen (default) Existing No (Right-315) Window 23 Northwest Exterior Wall 3.5 6.0 1 21.0 0.59 0.57 Insect Screen (default) Existing No (Right-315) Window Al Notheast Exterior Wall (Front-45) 6.0 9.0 1 54.0 0.40 0.19 Insect Screen (default) Altered n/a Window 01 Notheast Exterior Wall (Front-45) 1.0 9.0 1 9.0 0.28 0.23 Insect Screen (default) Altered n/a Window 02 Notheast Exterior Wall (Front-45) 1.0 9.0 1 9.0 0.28 0.23 Insect Screen (default) Altered n/a Window 03 Notheast Exterior Wall (Front-45) 8.0 2.3 1.033 19.0 0.28 0.23 Insect Screen (default) Altered n/a Window 04 Notheast Exterior Wall (Front-45) 3.5 5.0 0.971 17.0 0.59 0.57 Insect Screen (default) Altered n/a Window 36 Notheast Exterior Wall (Front-45) 3.5 5.0 0.971 17.0 0.59 0.57 Insect Screen (default) Existing No Window F1 Southwest Exterior Wall 2 16.5 11.7 1 193.1 0.41 0.29 Insect Screen (default) Altered n/a (Back-225) Window H3 Northwest Exterior Wall 2 9.0 9.0 1 81.0 0.65 0.43 Insect Screen (default) Existing No (Right-315) Registration Number: 419-P010105534A-000-000-0000000-0000 Registration Date/Time: 09/26/2019 08:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:27:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Hagerty Remodel Calculation Description: Title 24 Analysis Calculation Date/Time: 08:26, Thu, Sep 26, 2019 Input File Name: Haggerty Remodel.ribd16x Page 6 of 14 Window 131 Northeast Exterior Wall 2 (Front-45) 8.0 8.0 1 64.0 0.65 0.43 Insect Screen (default) Existing No Window 11 Northeast Exterior Wall 2 (Front-45) _ ____ 1 18.0 1.04 0.76 Insect Screen (default) Existing No Window D1 Southeast Exterior Wall 2 (Left-135) 8.0 8.0 1 64.0 0.65 0.43 Insect Screen (default) Existing No Window 10 Southeast Exterior Wall 2 (Left-135) 5.0 1.0 2 10.0 0.59 0.57 Insect Screen (default) Existing No Window 14 Southeast Exterior Wall 2 (Left-135) 3.0 6.0 1 18.0 0.59 0.57 Insect Screen (default) Existing No Window E1 Southwest Exterior Wall 3 (Back-225) 8.0 9.0 1 72.0 0.65 0.43 Insect Screen (default) Existing No Window E2 Southwest Exterior Wall 3 (Back-225) 8.0 9.0 1 72.0 0.65 0.43 Insect Screen (default) Existing No Window 13 Southwest Exterior Wall 3 (Back-225) __ 1 18.0 1.04 076 Insect Screen (default) Existing No Window 05 Northwest Exterior Wall 3 (Right-315) 3.0 5.0 1 15.0 0.59 0.57 Insect Screen (default) Existing No Window 06 Northwest Exterior Wall 3 (Right-315) 3.0 5.0 1 15.0 0.59 0.57 Insect Screen (default) Existing No Window 07 Northwest Exterior Wall 3 (Right-315) ! 3.0 5.0 1 15.0 0.59 0.57 Insect Screen (default) Existing No Window 08 Northwest Exterior Wall 3 (Right-315) 3.5 5.0 1 17.5 0.59 0.57 Insect Screen (default) Existing No Skylight Roof (- specify --0) ---- -- 1 6.0 0.80 0.40 None Existing No Skylight 2 Roof (- specify -0) -- ---- 1 6.0 0.80 0.40 None Existing No Window 31 Southeast Exterior Wall 3 (Left-135) 3.5 5.0 1 17.5 0.59 0.57 Insect Screen (default) Existing No Window 32 Southeast Exterior Wall 3 (Left-135) 1.3 1.3 1.036 1.8 0.59 0.57 Insect Screen (default) Existing No Window 33 Southeast Exterior Wall 3 (Left-135) 1.3 1.3 1.053 1.8 0.59 0.57 Insect Screen (default) Existing No Window 34 Southeast Exterior Wall 3 (Left-135) 1.3 1.3 1.053 1.8 0.59 0.57 Insect Screen (default) Existing No Window 35 Southeast Exterior Wall 3 (Left-135) 1.3 1.3 1.053 1.8 0.59 0.57 Insect Screen (default) Existing No Window i1 :1 Southwest Exterior Wall 4 (Left-135) 6.0 8.0 1 48.0 0.65 0.43 Insect Screen (default) Existing No Registration Number: 419-P010105534A-000-000-0000000-0000 Registration DateMme: 09/26/2019 08:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:27:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Hagerty Remodel Calculation Date/Time: 08:26, Thu, Sep 26, 2019 CFI R-PRF-01 Page 7 of 14 Calculation Description: Title 24 Analysis Input File Name: Haggerty Remodel.ribd16x Window 24 Southwest Exterior Wall 4 35.0 5.0 0.1 17.5 0.59 0.57 Insect Screen (default) Existing No (Left-135) Window 25 Northwest Exterior Wall 4 (Rig ht-315) 3.5 5.0 1 17.5 0.59 0.57 Insect Screen (default) Existing No Skylight 3 Roof 2 (- specify --0) — I --- 1 6.0 0.80 1 0.40 1 None Existing No OPAQUE DOORS 01 02 03 04 05 06 Name Side of Building Area (ft2) U-factor Status Verified Existing Condition Door G1 Southeast Exterior Wall 24.0 0.50 Existing No Door L3 Northeast Exterior Wall 3 24.0 0.50 Existing No Registration Number: 419-P010105534A-000-000-0000000-0000 Registration Date/Time: 09/26/2019 08:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:27:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Hagerty Remodel Calculation Date/Time: 08:26, Thu, Sep 26, 2019 CF1 R-PRF-01 Calculation Description: Title 24 Analysis Input File Name: Haggerty Remodel.ribd16x Page 8 of 14 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window H2 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window G2 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window 15 3 0.1 3 I 3 0 0 0 0 0 0 0 0 0 Window H1 3 0.1 3 3 0 0 0 I 0 0 0 0 0 0 Window 16 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window 17 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window 18 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window 19 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window 21 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window 20 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window 22 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window 23 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window Al 2 0.1 2 2 0 0 0 0 0 1 0 0 0 0 Window 01 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 02 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 03 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 04 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 36 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window F1 20 0.1 10 10 0 0 0 0 0 0 0 0 0 Window H3 4 0.1 4 4 0 8 0 0.1 0 8 0 0.1 0 Window B1 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window D1 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 10 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 14 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window E1 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window E2 4 0.1 I 4 4 0 0 0 0 0 0 0 0 0 Window 05 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window 06 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Registration Number: 419-P010105534A-000-000-0000000-0000 Registration Date/Time: 09/26/2019 08:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:27:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Hagerty Remodel Calculation Date/Time: 08:26, Thu, Sep 26, 2019 Calculation Description: Title 24 Analysis Input File Name: Haggerty Remodel.ribd16x CF1 R-PRF-01 Page 9 of 14 Window 07 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window 08 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window 31 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window 32 3 0.1 3 3 0 4 0 0.1 0 0 0 0 0 Window 33 3 0.1 3 3 0 4 0 0.1 0 0 0 0 0 Window 34 3 0.1 3 3 0 4 0 0.1 0 0 0 0 0 Window 35 3 0.1 3 3 0 4 0 0.1 0 0 0 0 0 Window i1 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window 24 3 0.1 3 3 0 0 0 0 0 0 0 0 0 Window 25 3 0.1 3 3 0 0 0 0 J 0 0 0 0 0 Registration Number: 419-P010105534A-000-000-0000000-0000 Registration Date/Time: 09/26/2019 08:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:27:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Hagerty Remodel Calculation Date/Time: 08:26, Thu, Sep 26, 2019 CF1 R-PRF-01 Calculation Description: Title 24 Analysis Input File Name: Haggerty Remodel.ribd16x Page 10 of 14 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofZone 1 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 R-21 Walll Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.064 Other Side Finish: Gypsum Board • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-14.3/2x6 R-38 Roof Attic attic) Wood Framed Ceiling 2x6 @ 16 in. O.C. R 38 0.026 Over Ceiling Joists: R-23.7 insul. • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck., Wood Siding/sheathing/decking Attic RoofZone 2 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity/Frame: no insuL /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofZone 3 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Cavity/Frame: R-38/2x6 Roof Deck: Wood Siding/sheathing/decking R-38 Roof Atticl Cathedral Ceilings Wood Framed Ceiling 2x6 @ 16 in. O.C. R 38 0.036 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofZone 4 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 08 09 Verified Perimeter Carpeted Existing Name Zone Area (ft2) (ft) Edge Insul. R-value Fraction Heated Status Condition Slab -on -Grade Zone 1 1437 120 None 1 No Existing No Slab -on -Grade 2 Zone 2 1450 70 None 1 No Existing No Slab -on -Grade 3 Zone 3 1276 80 I None 1 No Existing No Slab -on -Grade 4 Zone 4 945 40 None 1 No Existing No Registration Number: 419-P010105534A-000-000-0000000-0000 Registration Date/Time: 09/26/2019 08:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:27:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Hagerty Remodel Calculation Date/Time: 08:26, Thu, Sep 26, 2019 CFI R-PRF-01 Page 11 of 14 Calculation Description: Title 24 Analysis Input File Name: Haggerty Remodel.ribdl6x BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 2 0 Existing No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model Tank Location or Ambient Condition DHW Heater 1 Gas Small Storage 2 50 0.525 EF <= 75 kBtu/hr 0 n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Status Verified Existing Condition HVAC System 11 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 New No HVAC System 22 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 New No HVAC System 23 Other Heating and Cooling System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 New No HVAC System 44 Other Heating and Cooling System Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4 Existing No Registration Number: 419-P010105534A-000-000-0000000-0000 Registration Date/Time: 09/26/2019 08:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:27:34 CF1 R-PRF-01 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Hagerty Remodel Calculation Date/Time: 08:26, Thu, Sep 26, 2019 Calculation Description: Title 24 Analysis Input File Name: Haggerty Remodel.ribd16x Page 12 of 14 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 I CntrlFurnace 1 80 AFUE Heating Component 2 CntrlFurnace 1 80 AFUE Heating Component 3 CntrlFurnace 1 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Efficiency Name System Type Number of Units EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 11.5 14 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 1 11.5 14 Not Zonal Single Speed Cooling Component 2-hers-cool Cooling Component 3 SplitAirCond 1 11.5 14 Not Zonal Single Speed Cooling Component 3-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Not Required n/a Not Required Not Required Not Required Cooling Component 2-hers-cool Not Required n/a Not Required Not Required Not Required Cooling Component 3-hers-cool Not Required n/a Not Required Not Required Not Required Registration Number: 419-P010105534A-000-000-0000000-0000 Registration Date/Time: 09/26/2019 08:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:27:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Hagerty Remodel Calculation Date/Time: 08:26, Thu, Sep 26, 2019 Calculation Description: Title 24 Analysis Input File Name: Haggerty Remodel.ribd16x CF1 R-PRF-01 Page 13 of 14 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R-value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not System 1 (Ventilated and specified) 6.0 Attic Attic None Existing No n/a Unventilated) Air Distribution Ducts located in attic Existing (not System 2 (Ventilated and specified) 6.0 Attic Attic None Existing No n/a Unventilated) Air Distribution Ducts located in attic Existing (not System 3 (Ventilated and specified) 6.0 Attic Attic None Existing No n/a Unventilated) Air Distribution Ducts located in attic Existing (not System 4 (Ventilated and specified) 6.0 Attic Attic None Existing No n/a Unventilated) HVAC - FAN SYSTEMS & HERS VERIFICATION 01 02 03 04 Name Type I Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 --- HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 -- IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 0.25 Default 0 Not Required Registration Number: 419-P010105534A-000-000-0000000-0000 Registration Date/Time: 09/26/2019 08:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:27:34 CF1 R-PRF-01 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Hagerty Remodel Calculation Date/Time: 08:26, Thu, Sep 26, 2019 Calculation Description: Title 24 Analysis Input File Name: Haggerty Remodel.ribdl6x Page 14 of 14 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Butch White 31tdv k)hite/ Company: Signature Date: Breeze Air Conditioning LLC 09/26/2019 Address: CEA/HERS Certification Identification (If applicable) 75-145 Street Charles Place City/State/Zip: Phone: Palm Desert, CA 92211 (760) 346-0855 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Butch White 3 utck W hit e/ Company: Date Signed: Breeze Air Conditioning LLC 09/26/2019 Address: License: 75-145 Street Charles Place 1045015 City/State/Zip: Phone: Palm Desert, CA 92211 (760) 346-0855 Digitally signed by CHEERSTm. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 419-P010105534A-000-000-0000000-0000 Registration Date/Time: 09/26/2019 08:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:27:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Haggerty Guest Hiuse Remodel Calculation Date/Time: 08:02, Thu, Sep 26, 2019 Calculation Description: Title 24 Analysis Input File Name: Haggerty Guest House Remodel.ribd16x 17A" A CF1 R-PRF-01 Page 1 of 6 GENERAL INFORMATION I C ITY 0 F LA U U 111 I = 01 I Project Name Haggerty Guest Hiuse Remodel BUILDINU LAVf AU" 02 Calculation Description Title 24 Analysis REVItW ltu r-ur-1 03 Project Location 79-705 Tom Fazio Lane UUL)C: 04 City La Quinta GO I I erg^r `°�` Sta dards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15� Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 0 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 463 15 Number of Zones 1 16 Slab Area (ft2) 463 17 Number of Stories 1 18 Addition Cond. Floor Area (ft2) 0 19 Natural Gas Available Yes 20 i Addition Slab Area (ft2) 0 21_glazing d=�k =-I Percents a %) 0. 1 r— 12.4% mr.mid Alllr) I)MIrl r10M951T f 0ADTMPJT ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 5.62 5.62 0.00 0.0% Space Cooling 210.03 210.03 0.00 0.0% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 49.51 49.51 0.00 0.0% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 1265.16 1 265.16 0.00 0.0% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins Registration Number: 419-P010105535A-000-000-0000000-0000 Registration Date/Time: 09/26/2019 08:49 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 y4 HERS Provider: CHEERS Report Generated at: 2019-09-26 08:03:02s CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Haggerty Guest Hiuse Remodel Calculation Date/Time: 08:02, Thu, Sep 26, 2019 CFI R-PRF-01 Page 2 of 6 Calculation Description: Title 24 Analysis HERS FEATURE SUMMARY Input File Name: Haggerty Guest House Remodel.ribd16x The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • --None-- Cooling System Verifications: • --None -- HVAC Distribution System Verifications: • --None -- Domestic Hot Water System Verifications: • --None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Haggerty Guest Hiuse Remodel I 463 I 1 1 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Conditioned Living Space Conditioned HVAC System 11 463 8 I DHW Sys 1 n/a OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft) Tilt (deg) Wall Exception Status Verified Existing Condition Southwest Exterior Wall Conditioned Living Space R-21 Wall 135 135 420 41.5 90 n/a Existing No Northeast Exterior Wall Conditioned Living Space R-21 Wall 45 45 420 35 90 n/a Existing No Southeast Exterior Wall Conditioned Living Space R-21 Wall 135 135 280 5 90 n/a Existing No Northwest Exterior Wall Conditioned Living Space I R-21 Wall 45 45 280 0 90 n/a Existing No Roof Conditioned Living Space R-38 Roof Attic 463 n/a Existing No Registration Number: 419-P010105535A-000-000-0000000-0000 Registration Date/Time: 09/26/2019 08:49 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:03:02 CF1 R-PRF-01 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Haggerty Guest Hiuse Remodel Calculation Date/Time: 08:02, Thu, Sep 26, 2019 Calculation Description: Title 24 Analysis Input File Name: Haggerty Guest House Remodel.ribd16x Page 3 of 6 ATTIC 01 02 03 04 05 06 07 08 09 10 Roof Roof Radiant Cool Verified Existing Name Construction Type Roof Rise Reflectance Emittance Barrier Roof Status Condition Attic Conditioned Living Space Attic RoofCondditi ned Living Ventilated 4 0.1 0.85 Yes No Existing No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 Verified Existing Name Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft) U-factor SHGC Exterior Shading Status Condition Window 37 Southwest Exterior Wall (- specify 3.5 5.0 1 17.5 0.59 0.37 Insect Screen (default) Existing No --135) Window 38 Northeast Exterior Wall (- specify 3.5 5.0 1 17.5 0.59 0.37 Insect Screen (default) Existing No Window39 Northeast Exterior Wall (- specify 3.5 5.0 1 17.5 0.59 0.37 Insect Screen (default) Existing No Window 40 Southeast ExteriorWall (- specify 5.0 1.0 1 5.0 0.59 0.37 Insect Screen (default) Existing No OPAQUE DOORS 01 02 03 04 05 06 Name Side of Building Area (ft) U-factor Status Verified Existing Condition Door N1 Southwest Exterior Wall 24.0 0.70 Existing No OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window 37 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 38 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window39 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 40 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Registration Number: 419-P010105535A-000-000-0000000-0000 Registration Date/Time: 09/26/2019 08:49 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:03:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Haggerty Guest Hiuse Remodel Calculation Date/Time: 08:02, Thu, Sep 26, 2019 Calculation Description: Title 24 Analysis Input File Name: Haggerty Guest House Remodel.ribd16x CF1 R-PRF-01 Page 4 of 6 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Construction Name Surface Type Construction Type Framing Total Cavity R-value Winter Design U-factor Assembly Layers Attic RoofConditioned Living I Space Attic Roofs Wood Framed Ceiling 2x4 Top Chord of Roof Truss @ 24 in. O.C. none 0.644 • Cavity/Frame: no insul. /2x4 Top Chrd Roof Deck: Wood Siding/sheathing/decking Roofing: Light Roof (Asphalt Shingle) R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 Exterior Finish: 3 Coat Stucco R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x6 @ 24 in. O.C. R 38 0.025 • Inside Finish: Gypsum Board Cavity/Frame: R-14.3/2x6 Over Ceiling Joists: R-23.7 insul. SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value Carpeted Fraction Heated Status Verified Existing Condition Slab -on -Grade Conditioned Living Space 463 120 None 1 No I Existing No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction M Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 0 Existing No Registration Number: 419-P010105535A-000-000-0000000-0000 Registration DateMme: 09/26/2019 08:49 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:03:02 CF1 R-PRF-01 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Haggerty Guest Hiuse Remodel Calculation Daterrime: 08:02, Thu, Sep 26, 2019 Calculation Description: Title 24 Analysis Input File Name: Haggerty Guest House Remodel.ribdl6x Page 5 of 6 WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model Tank Location or Ambient Condition DHW Heater 1 Gas Small Storage 1 50 0.525 EF <= 75 kBtu/hr 0 n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Status Verified Existing Condition F I HVAC System 11 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 AirSystemution j Existing No HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Name Type Duct Leakage Insulation R-value Supply Duct Location Return Duct Location Bypass Duct Status Verified Existing Condition HERS Verification Air Distribution System 1 Ducts located in attic (Ventilated and Unventilated) Existing (not specified) 8.0 Attic Attic None Existing No n/a IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 0.25 Default 0 Not Required Registration Number: 419-P010105535A-000-000-0000000-0000 Registration Date/Time: 09/26/2019 08:49 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:03:02 (,ERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Haggerty Guest Hiuse Remodel Calculation Description: Title 24 Analysis Calculation Date/Time: 08:02, Thu, Sep 26, 2019 Input File Name: Haggerty Guest House Remodel.ribdl6x Page 6 of 6 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Butch White Bat v wl N te,, Company: Signature Date: Breeze Air Conditioning LLC 09/26/2019 Address: CEA/HERS Certification Identification (If applicable): 75-145 Street Charles Place City/State/Zip: Phone: Palm Desert, CA 92211 (760) 346-0855 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Butch White 13 Ltt v wl Wel Company: Date Signed: Breeze Air Conditioning LLC 09/26/2019 Address: License: 75-145 Street Charles Place 1045015 City/State/Zip: Phone: Palm Desert, CA 92211 (760) 346-0855 Digitally signed by CHEERSTM. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 419-P010105535A-000-000-0000000-0000 Registration Date/Time: 09/26/2019 08:49 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-26 08:03:02