Griffin Ranch - Castilla Collection TR 32879 (Plans 1-3) Revision 1 - Title 24TITLE 24 ENERGY COMPLIANCE REPORT FOR: CASTILLA @ GRIFFIN RANCH La Quinta Climate Zone 15 PREPARED FOR: Trans West Housing Plans for CASTILLA @ GRIFFIN RANCH have been revie The following Title 24 energy report demonstrates compliance with California's Title 24 energy code for new residential projects. Mark Gallant, CEA/CEPE, HERs Rater CITY pF LA QUINTA BUILDING & SAFETY DEPT. APPROVED . FOR( CO / DA l r- / PREPARED BY: HAYNAL & COMPANY INC. 508 W Mission Ste 201 Escondido, CA 92025 760-743-5408 July 9, 2007 2005 CODE, Micropas 7.3 20-LIC#649028, HERS Rater www.title-24.com email: mark@title-24.com �l JUL 2 6 2001 MINIMUM REQUIREMENT SUMMARY: TITLE 24 COMPLIANCE Y Each of the following specific items, the MF-1R page, and the signed CF-1R pages must be clearly listed on the plans, and provided to the homeowners upon assuming occupancy. Project CASTILLA @ GRIFFIN RANCH 2005 CODE 7/9/2007 Ceiling Insulation R38 Wall Insulation I R13+R4 Fenestration (Windows) Dual (Vinyl or Wood) LowE2 Ufactor=0.39 SHGC=0.36 Fenestration (Fixed) Dual (Vinyl or Wood) LowE2 Ufactor=0.35 SHGC=0.36 Fenestration (Doors) Dual (Vinyl or Wood) LowE2 Ufactor-0.36 SHGC=0.36 Water Heating 75 Gal Gas. Recovery Eff=0.80, A.O. Smith FCG-75, Input=75100, FHR=127 (or equal) Recirc Pump with Timer and Temp Sensor, R12 External Blanket R-4 Pipe Insulation required with Recirc Pump Option HVAC System Heating Efficiency 80% AFUE minimum Cooling Efficiency 13.0 SEER minimum 11.5 EER TXV Valve Required Duct Insulation R-4.2 Tight Duct Test Required Thermostat Setback Recommended Heat/Cooling Loads CFA %/Gls Heat Min Sensible T.Cool CFM Tons Plan 1 Z1 1558 26.7 46133 29732 36868 1600 4 Plan 1 Z2 1044 17.7 28216 16293 20203 1200 3 Plan 1 Total 2602 23.1 74350 46025 57071 Plan 1+Office Z1 1721 27.6 49446 33255 41236 2000 5 Plan 1+Office Z2 1044 17.7 28216 16020 19865 1200 3 Plan 1+Office Total 2765 23.8 77663 49275 61101 Plan 2 Z1 1513 30.3 40444 30105 37330 1600 4 Plan 2 Z2 1313 18.4 33802 21644 26839 1400 3.5 Plan 2 Total 2826 24.8 74246 51749 64169 Plan 3 Z1 1960 27.5 52544 34272 42497 2000 5 Plan 3 Z2 1188 16.5 31236 17075 21173 1200 3 Plan 3 Total 3148 23.3 83780 51347 63670 HVAC Recommendations FAU/AC (or equal) I Tons I Sensiblel Capacity I In ut Plan 1 Zl Rheem RGPN07NAMGR 60000 75000 Rheem 13AJA-048 4.0 34050 47000 Plan 1 Z2 Rheem RGPN05NAUER 41000 50000 Rheem 13AJA-036 3.0 25100 34400 Plan 1+Office Z1 Rheem RGPN10NBRJR 81000 100000 Rheem 13AJA-060 5.0 40500 58500 Plan 1+Office Z2 Rheem RGPN05NAUER 41000 50000 Rheem 13AJA-036 3.0 25100 34400 Plan 2 Z1 Rheem RGPN07NAMGR 60000 75000 Rheem 13AJA-048 4.0 34050 47000 Plan 2 Z2 Rheem RGPN07NAMGR 60000 75000 Rheem 13AJA-042 3.5 29900 41500 Plan 3 Z1 Rheem RGPN10NBRJR 81000 100000 Rheem 13AJA-060 5.0 40500 58500 Plan 3 Z2 Rheem RGPN05NAUER 41000 50000 Rheem 13AJA-036 3.0 25100 34400 Note: the UBC requires that the heating system be capable of maintaining a temperature of 70 degrees at three feet above the floor throughout the conditioned space of the residence. The recommendations above is based on the attached heating and/or cooling load calculations. DHW is based on UPC Table 5-1. THE CONTRACTORS ARE RESPONSIBLE FOR THE FINAL SIZING OF HEATING, COOLING AND DHW EQUIPMENT. MANDATORY MEASURES SUMMARY: RESIDENTIAL (Page 1 of 2) MF-1 R Project Title' Date Note: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or check NA if not applicable. DESCRIPTION NA Designer Enforcement Building Envelope Measures: V/ 1/ V/ * §150(a): Minimum R-19 in wood frame ceiling insulation or equivalent U-factor in metal frame ceiling ❑ §150(b): Loose fill insulation manufacturer's labeled R-Value: 0 ❑ * §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls). * §150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor. 0 ❑ ❑ §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closeable metal or glass door covering the entire opening of the firebox ❑ 0 El b. outside air intake with damper and control, flue damper and control ❑ 0 2. No continuous burning gas pilot lights allowed. ❑ 0 11 §150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. 0 ❑ ❑ §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 0 ❑ ❑ §150(I) : Slab edge insulation - water absorption rate for the insulation material alone without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch. [J1 §118: Insulation specified or installed meets insulation installation quality standards. Indicate type & include CF-6R Form: §116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ 0 ❑ 2. Fenestration products (except field -fabricated) have label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 0 Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ 0 El §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. 11 0 El §150(i): Setback thermostat on all applicable heating and/or cooling systems. 11 0 El §1500): Water system pipe and tank insulation and cooling systems line insulation. ❑ 0 0 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R-value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A. 0 El rsesiaential Compnance Forms March 2005 MANDATORY MEASURES SUMMARY: RESIDENTIAL (Paae 2 of 2) MF-1 R Space Conditioning, Water Heating and Plumbing System Measures: (continued) NA Designer Enforcement x ✓ ✓ ✓ 5. Insulation must be protected from damage, including that due to sunlight, moisture,equipment maintenance and wind Q 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. 0 §150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirement of the CIVIC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than M Li sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. El 2 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. QEl §114: Pool and Spa Heating Systems and Equipment. 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. at least 36" of pipe between filter and heater for future solar heating Q b. cover for outdoor pools or outdoor spas Q ❑ El 3. Pool system has directional inlets and a circulation pump time switch. Q ❑ ❑ §115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no El 0 El burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118(i): Cool Roof material meets specified criteria 0 El El Residential Lighting Measures: §150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic and have an output frequency no less than 20 kHz §150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table El 150-C, hardwired ballasts and if the ballast is electromagnetic has a medium screw base socket. §150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the total rated wattage of permanently installed luminaires (based on nominal rated wattage of high efficacy lamps) in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. §150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms utility rooms shall be high efficacy R1 El luminaires. OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option. §150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and Li utility rooms shall be high efficacy luminaires (except closets less than 70ft2): OR are controlled by a dimmer switch OR are controlled by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always onoption. §150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are rated to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. §150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). §150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec.130,132, & 147. El Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec.130,131, & 146. §150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). uai vvl i ly lai we rut 11 is Marcn ZUUJ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 1 Project Title.......... Plan 1 Date..07/09/07 14:26:38 Project Address........ CASTILLA @ GRIFFIN RANCH ******* --------------------- La Quinta *v7.30* I I Documentation Author... Mark Gallant, CEPE/CEA ******* I Building Permit # I Haynal and Company, Inc. I I 508 W Mission Ave Ste 201 I Plan Check / Dated Escondido, CA 92025 I I 760-743-5408 I Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.30 for 2005 Standards by Enercomp, Inc. MICROPAS7 v7.30 File-CASTII Wth-CTZ15S05 Program -FORM CF-lR I User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) ---------------------------------- Design Design ---------- Margin = ---------- = Space Heating.......... 2.94 2.65 - 0.29 = = Space Cooling.......... 81.15 70.64 10.51 = = Water Heating.......... 9.87 10.04 -0.17 = = North Total 93.96 83.33 10.63 = = Space Heating.......... 2.94 2.67 0.27 = = Space Cooling.......... 81.15 73.97 7.18 = = Water Heating.......... 9.87 10.04 -0.17 = = East Total 93.96 86.68 7.28 = = Space Heating.......... 2.94 2.67 0.27 = = Space Cooling.......... 81.15 71.38 9.77 = = Water Heating.......... 9.87 10.04 -0.17 = = South Total 93.96 84.09 9.87 = = Space Heating.......... 2.94 2.56 0.38 = = Space Cooling.......... 81.15 73.94 7.21 = = Water _ Heating.......... 9.87 10.04 -0.17 = = West Total -------- 93.96 -------- 86.54 -------- - 7.42 = _ *** Building complies with Computer Performance _ *** HERS Verification Required for Compliance *** _ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2 Project Title.......... Plan 1 Date..07/09/07 14:26:38 MICROPAS7 v7.30 File-CASTII Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Conditioned Floor Area..... Building Type .............. Construction Type ......... Fuel Type ................. Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Required 2602 sf Single Family Detached New NaturalGas Cardinal - N,E,S,W 1 1 FullYear Slab On Grade 2 27519 cf 2602 sf 23.1 % of floor area 0.37 Btu/hr-sf-F 0.36 10.6 ft BUILDING ZONE INFORMATION Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type -------------- (sf) ----- (cf) Units ------ ----- le ----- ioned ----- Type -------- (ft) (sf) Housewrap 1 ---------------------- Residence 1558 17079 0.59 2.9 Yes Setback 2.0 Standard No 2 Residence 1044 10440 0.41 2.0 Yes Setback 2.0 Standard No OPAQUE SURFACES U- --------------- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface ------------ Type (sf) or R-val R-val Azm Tilt Reference Comments 1 ----- ---- ----- ----- ----- --- ---- --- ----------------------- 1 Wall Wood 488 0.068 13 4 0 90 Yes IV.9 C3 3 Wall Wood 109 0.068 13 4 0 90 No IV.9 C3 To Garage 4 Wall Wood 298 0.068 13 4 90 90 Yes IV.9 C3 6 Wall Wood 40 0.068 13 4 90 90 No IV.9 C3 7 Wall Wood 518 0.068 13 4 180 90 Yes IV.9 C3 9 Wall Wood 501 0.068 13 4 270 90 Yes IV.9 C3 11 Roof Wood 1558 0.025 38 0 n/a 0 Yes IV.1 A18 13 Door Other 21 0.500 0 0 0 90 No IV.5 A4 Garage Door 2 2 Wall Wood 155 0.068 13 4 0 90 Yes IV.9 C3 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3 Project Title.......... Plan 1 Date..07/09/07 14:26:38 MICROPAS7 v7.30 File-CASTII Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface ------------ Type (sf) or R-val R-val Azm Tilt Reference Comments 5 Wall ----- Wood ---- 549 ----- 0.068 ----- 13 ----- 4 --- 90 ---- 90 --- Yes ----------------------- IV.9 C3 8 Wall Wood 118 0.068 13 4 180 90 Yes IV.9 C3 10 Wall Wood 364 0.068 13 4 270 90 Yes IV.9 C3 12 Roof Wood 1044 0.025 38 0 n/a 0 Yes IV.1 A18 PERIMETER LOSSES Appendix Length F2 Insul Solar IV Location/ Surface ------------ (ft) ------ Factor R-val Gains Reference Comments 1 -------- ------- ----- --------- ---------------------- 14 S1abEdge 215 0.730 R-0 No IV.26 Al To Outside 2 15 SlabEdge 132 0.730 R-0 No IV.26 Al To Outside FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation ------------------ (sf) ----- factor SHGC ----- ----- Azm Tilt Type Location/Comments 1 --- ---- -------- ------------------- 1 Wind Front (N) 49.5 0.390 0.360 0 90 Standard F.3.3056 2 Wind Front (N) 22.5 0.350 0.360 0 90 Standard F.3.3026 3 Door Front (N) 24.0 0.360 0.360 0 90 Standard F.3080E 4 Wind Front (N) 16.5 0.390 0.360 0 90 Standard F.3056 $ Wind Left (E) 8.0 0.350 0.360 90 90 Standard L.2040 6 Wind Right (W) 8.8 0.390 0.360 270 90 Standard R.2636 7 Wind Right (W) 10.0 0.390 0.360 270 90 Standard R.2050A 8 Wind Back (S) 4.0 0.350 0.360 180 90 Standard B.2020 9 Wind Right (W) 10.0 0.350 0.360 270 90 Standard R.2050FX 10 Wind Right (W) 10.0 0.390 0.360 270 90 Standard R.2050 11 Wind Back (S) 48.0 0.390 0.360 180 90 Standard B.8060 12 Wind Left (E) 10.0 0.390 0.360 90 90 Standard L.2050 13 Door Left (E) 24.0 0.360 0.360 90 90 Standard L.3080 14 Wind Left (E) 10.0 0.390 0.360 90 90 Standard L.2050a 15 Door Back (S) 64.0 0.360 0.360 180 90 Standard B.8080 16 Wind Back (S) 24.0 0.350 0.360 180 90 Standard B.8030 17 Wind Back (S) 49.5 0.390 0.360 180 90 Standard B.3.3056 18 Wind Back (S) 22.5 0.350 0.360 180 90 Standard B.3.3026 2 19 Wind Front (N) 13.8 0.390 0.360 0 90 Standard F.2656 20 Wind Front (N) 21.0 0.350 0.360 0. 90 Standard F.3660 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 Project Title.......... Plan 1 Date..07/09/07 14:26:38 MICROPAS7 v7.30 File-CASTII Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- Orientation 21 Wind Right 22 Door Back 23 Door Right 24 Wind Back 25 Wind Left 26 Wind Left 27 Wind Left 28 Wind Left Surface 1 4 Window 13 Door 14 Window 15 Door 16 Window 17 Window 18 Window 2 22 Door 23 Door FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade (sf) factor SHGC Azm Tilt Type ---- (W) ----- 12.5 ----- 0.390 ----- 0.360 --- 270 ---- 90 (S) 24.0 0.360 0.360 180 90 (W) 24.0 0.360 0.360 270 90 (S) 48.0 0.390 0.360 180 90 (E) 12.5 0.390 0.360 90 90 (E) 7.5 0.390 0.360 90 90 (E) 6.3 0.390 0.360 90 90 (E) 15.0 0.390 0.360 90 90 OVERHANGS Location/Comments ----------------- Standard R.2650 Standard B.3080FR Standard R.3080 Standard B.8060a Standard L.2650 Standard L.1650 Standard L.2626 Standard L.3050A ---Window--- ------------ Overhang ------------ Area Left Right (sf) Width Height Depth Height Extension Extension ---- ----- ------ ----- ------------------------ 16.5 n/a 5.5 16 3 n/a n/a 24.0 n/a 8 48 1 n/a n/a 10.0 n/a 5 48 1 n/a n/a 64.0 n/a 8 13 3 n/a n/a 24.0 n/a 3 13 1 n/a n/a 49.5 n/a 5.5 13 3 n/a n/a 22.5 n/a 2.5 13 1 n/a n/a 24.0 n/a 8 29 1 24.0 n/a 8 48 1 SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ 1 Standard Slab 1558 2 Standard Slab 1044 n/a n/a n/a n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5 Project Title.......... Plan 1 Date..07/09/07 14:26:38 MICROPAS7 v7.30 File-CASTII Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- HVAC SYSTEMS Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type Systems Efficiency EER or TXV Airflow Draw Capacity ------------ 1 ------- ----------- -------------------------- -------- -------- Furnace 1 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 1 13.00 SEER 11.5 Yes No No No 2 Furnace 1 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 1 13.00 SEER 11.5 Yes No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) (Btu/hr) -------------------- (Btu/hr) 1 ---------- Furnace 30553 n/a n/a n/a ACSplit n/a 29732 37011 n/a 2 Furnace 17776 n/a n/a n/a ACSplit ------------- n/a ---------- 16293 20282 ---------- n/a Total 48330 ---------- 46025 57292 ---------- n/a Orientation of Maximum..... Front Facing 270 deg (W) Sizing Location............ PALM DESERT Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R-value Leakage Area Ducts ----------------------------------------------------- 1 Furnace Attic R-4.2 Yes No No ACSplit Attic R-4.2 Yes No No 2 Furnace Attic R-4.2 Yes No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 6 Project Title.......... Plan 1 Date..07/09/07 14:26:38 MICROPAS7 v7.30 File-CASTII Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- DUCT SYSTEMS Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location R-value Leakage ----------- Area Ducts ACSplit -------------- Attic R-4.2 Yes -------- No -------- No WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Large Gas Recirc/TimeTemp 1 n/a 75 R-12 WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R-value Light ------------------------------------------------------------- ------ 1 Large 0.80 n/a 0.032 R- n/a n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a non-standard Water Heating System. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 7 Project Title.......... Plan 1 Date..07/09/07 14:26:38 MICROPAS7 v7.30 File-CASTII Wth-CTZ15S05 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION *** must be reported on the CF-4R installation certificate. *** This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 8 Project Title.......... Plan 1 Date..07/09/07 14:26:38 MICROPAS7 v7.30 File-CASTII Wth-CTZ15S05 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER Name.... Name.... Company. Trans West Housing Company. Address. 47120 Dune Palms Road, St Address. La Quinta CA 92253 Phone... (760)777-4307 Phone... License. Signed.. Signed.. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Mark Gallant, CEPE/CEA Haynal and Company, Inc. 508 W Mission Ave Ste 201 Escondido, CA 92025 760-743-5408 07-09-2007 (date) CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1 Project Title.......... Plan 1+Office Date..07/09/07 14:26:49 Project Address........ CASTILLA @ GRIFFIN RANCH ******* --------------------- La Quinta *v7.30* Documentation Author... Mark Gallant, CEPE/CEA ******* Building Permit # I Haynal and Company, Inc. 508 W Mission Ave Ste 201 ( Plan Check / Date Escondido, CA 92025 760-743-5408 ( Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.30 for 2005 Standards by Enercomp, Inc. --------------------- MICROPAS7 v7.30 File-CASTIIO Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) ---------------------------------- Design Design -------------------- Margin = = Space Heating.......... 2.79 2.59 - 0.20 = - Space Cooling.......... 79.41 69.57 9.84 = = Water Heating.......... 9.29 9.44 -0.15 = = North Total 91.49 81.60 9.89 = = Space Heating.......... 2.79 2.49 0.30 = - Space Cooling.......... 79.41 73.31 6.10 = = Water Heating.......... 9.29 9.44 -0.15 = = East Total 91.49 85.24 6.25 = = Space Heating.......... 2.79 2.42 0.37 = = Space Cooling.......... 79.41 71.12 8.29 = = Water Heating.......... 9.29 9.44 -0.15 = = South Total 91.49 82.98 8.51 = = Space Heating.......... 2.79 2.42 0.37 = - Space Cooling.......... 79.41 74.23 5.18 = - Water Heating.......... 9.29 9.44 -0.15 = = West Total 91.49 86.09 5.40 = _ *** Building complies with Computer Performance _ *** HERS Verification Required for Compliance *** _ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 Project Title.......... Plan 1+Office Date..07/09/07 14:26:49 MICROPAS7 v7.30 File-CASTIIO Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Conditioned Floor Area..... Building Type .............. Construction Type ......... Fuel Type ................. Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Floor Area Zone Type (sf) -------------- ----- 1 Residence 1721 2 Residence 1044 Required 2765 sf Single Family Detached New NaturalGas Cardinal - N,E,S,W 1 1 FullYear Slab On Grade 2 29108 cf 2765 sf 23.8 % of floor area 0.37 Btu/hr-sf-F 0.36 10.5 ft BUILDING ZONE INFORMATION ----------------- ------- # of # of Cond- Thermo- Vent Vent Verified Volume Dwell Peop- it- stat Height Area Leakage or (cf) Units le ioned Type (ft) (sf) Housewrap ------ ----- ----- ------------- ---------------------- 18668 0.67 3.4 Yes Setback 2.0 Standard No 10440 0.33 1.7 Yes Setback 2.0 Standard No OPAQUE SURFACES --------------- U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ ----- ---- ----- ----- ----- --- ---- --------------------- 1 1 Wall 3 Wall 4 Wall 6 Wall 7 Wall 9 Wall 11 Roof 13 Door 2 2 Wall Wood 440 0.068 13 4 0 90 Yes IV.9 C3 Wood 109 0.068 13 4 0 90 No IV.9 C3 Wood 298 0.068 13 4 90 90 Yes IV.9 C3 Wood 40 0.068 13 4 90 90 No IV.9 C3 Wood 518 0.068 13 4 180 90 Yes IV.9 C3 Wood 491 0.068 13 4 270 90 Yes IV.9 C3 Wood 1721 0.025 38 0 n/a 0 Yes IV.1 A18 Other 21 0.500 0 0 0 90 No IV.5 A4 Wood 155 0.068 13 4 0 90 Yes IV.9 C3 To Garage Garage Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3 Project Title.......... Plan 1+Office Date..07/09/07 14:26:49 MICROPAS7 v7.30 File-CASTIIO Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- OPAQUE SURFACES U- --------------- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface ------------ Type (sf) or R-val R-val Azm Tilt Reference Comments 5 Wall ----- Wood ---- 549 ----- 0.068 ----- ----- 13 4 --- ---- 90 --- 90 Yes ------------------ IV.9 C3 8 Wall Wood 118 0.068 13 4 180 90 Yes IV.9 C3 10 Wall Wood 364 0.068 13 4 270 90 Yes IV A C3 12 Roof Wood 1044 0.025 38 0 n/a 0 Yes IV A A18 PERIMETER LOSSES Appendix Length F2 Insul Solar IV Location/ Surface ------------ (ft) ------ Factor -------- R-val Gains Reference Comments 1 ------- ----- --------- ---------------------- 14 S1abEdge 215 0.730 R-0 No IV.26 Al To Outside 2 15 S1abEdge 132 0.730 R-0 No IV.26 Al To Outside FENESTRATION --------------------- SURFACES Exterior Area U- Act Shade Orientation ------------------ (sf) ----- factor SHGC ----- ----- Azm Tilt Type Location/Comments 1 --- ---- -------- ------------------------ 1 Wind Front (N) 49.5 0.390 0.360 0 90 Standard F.3.3056 2 Wind Front (N) 22.5 0.350 0.360 0 90 Standard F.3.3026 3 Door Front (N) 24.0 0.360 0.360 0 90 Standard F.3080E 4 Wind Front (N) 16.5 0.390 0.360 0 90 Standard F.3056 5 Wind Left (E) 8.0 0.350 0.360 90 90 Standard L.2040 6 Wind Right (W) 8.8 0.390 0.360 270 90 Standard R.2636 7 Wind Right (W) 10.0 0.390 0.360 270 90 Standard R.2050A 8 Wind Back (S) 4.0 0.350 0.360 180 90 Standard B.2020 9 Wind Right (W) 10.0 0.350 0.360 270 90 Standard R.2050FX 10 Wind Right (W) 10.0 0.390 0.360 270 90 Standard R.2050 11 Wind Back (S) 48.0 0.390 0.360 180 90 Standard B.8060 12 Wind Left (E) 10.0 0.390 0.360 90 90 Standard L.2050 13 Door Left (E) 24.0 0.360 0.360 90 90 Standard L.3080 14 Wind Left (E) 10.0 0.390 0.360 90 90 Standard L.2050a 15 Door Back (S) 64.0 0.360 0.360 180 90 Standard B.8080 16 Wind Back (S) 24.0 0.350 0.360 180 90 Standard B.8030 17 Wind Back (S) 49.5 0.390 0.360 180 90 Standard B.3.3056 18 Wind Back (S) 22.5 0.350 0.360 180 90 Standard B.3.3026 29 Door Front (N) 48.0 0.360 0.360 0 90 Standard F.6080OP 30 Wind Right (W) 10.0 0.390 0.360 270 90 Standard R.2050OP 2 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 Project Title.......... Plan 1+Office Date..07/09/07 14:26:49 MICROPAS7 v7.30 File-CASTIIO Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- Orientation 19 Wind Front (N) 20 Wind Front (N) 21 Wind Right (W) 22 Door Back (S) 23 Door Right (W) 24 Wind Back (S) 25 Wind Left (E) 26 Wind Left (E) 27 Wind Left (E) 28 Wind Left (E) FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade (sf) factor SHGC Azm Tilt Type Location/Comments ---- ----- ----- --- ------------ ------------------------ 13.8 0.390 0.360 0 90 Standard F.2656 21.0 0.350 0.360 0 90 Standard F.3660 12.5 0.390 0.360 270 90 Standard R.2650 24.0 0.360 0.360 180 90 Standard B.3080FR 24.0 0.360 0.360 270 90 Standard R.3080 48.0 0.390 0.360 180 90 Standard B.8060a 12.5 0.390 0.360 90 90 Standard L.2650 7.5 0.390 0.360 90 90 Standard L.1650 6.3 0.390 0.360 90 90 Standard L.2626 15.0 0.390 0.360 90 90 Standard L.3050A OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface ----------- (sf) ----- Width ----- Height Depth.Height Extension Extension 1 ------ ----- ------ --------- --------- 4 Window 16.5 n/a 5.5 16 3 n/a n/a 13 Door 24.0 n/a 8 48 1 n/a n/a 14 Window 10.0 n/a 5 48 1 n/a n/a 15 Door 64.0 n/a 8 13 3 n/a n/a 16 Window 24.0 n/a 3 13 1 n/a n/a 17 Window 49.5 n/a 5.5 13 3 n/a n/a 18 Window 22.5 n/a 2.5 13 1 n/a n/a 2 22 Door 24.0 n/a 8 29 1 n/a n/a 23 Door 24.0 n/a 8 48 1 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ---- 1 Standard Slab 1721 2 Standard Slab 1044 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5 Project Title.......... Plan 1+Office Date..07/09/07 14:26:49 MICROPAS7 v7.30 File-CASTIIO Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type Systems Efficiency EER or TXV Airflow Draw Capacity ------------ 1 ------- ----------- ----- ------------- -------- -------- -------- Furnace 1 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 1 13.00 SEER 11.5 Yes No No No 2 Furnace 1 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 1 13.00 SEER 11.5 Yes No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) 1 --------- Furnace 32236 n/a n/a n/a ACSplit n/a 33255 41395 n/a 2 Furnace 17776 n/a n/a n/a ACSplit ------------- n/a ---------- 16020 ---------- 19942 n/a Total 50013 49275 ---------- 61337 --------- n/a Orientation of Maximum..... Front Facing 270 deg (W) Sizing Location............ PALM DESERT Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R-value Leakage Area Ducts ---------------------------------------------------- 1 Furnace Attic R-4.2 Yes No No ACSplit Attic R-4.2 Yes No No 2 Furnace Attic R-4.2 Yes No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 6 Project Title.......... Plan 1+Office Date..07/09/07 14:26:49 MICROPAS7 v7.30 File-CASTIIO Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- DUCT SYSTEMS Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location R-value Leakage Area Ducts ACSplit ------------------------- Attic R-4.2 Yes -------- No -------- No Tank Type ---------------- 1 Large System 1 Large WATER HEATING SYSTEMS --------------------- Number Tank Heater in Energy Size Type Distribution Type System Factor (gal) -------- ------------------- -------------- ----- Gas Recirc/TimeTemp 1 n/a 75 WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss Insulation Efficiency Input Fraction R-value -------------------------------------------------- 0.80 n/a 0.032 R- n/a External Insulation R-value R-12 Pilot Light n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a non-standard Water Heating System. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7 Project Title.......... Plan 1+Office Date..07/09/07 14:26:49 MICROPAS7 v7.30 File-CASTIIO Wth-CT215S05 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION -------------------------- *** must be reported on the CF-4R installation certificate. *** This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1 Proj-ct Title.......... Plan 2 Date..07/09/07 14 27 01 Vrojeict Address........ CASTILLA @ GRIFFIN RANCH ******* --------------------- La Quinta *v7.30* I I Documentation Author... Mark Gallant, CEPE/CEA ******* I Building Permit # I Haynal and Company, Inc. I I 508 W Mission Ave Ste 201 I Plan Check / Date I Escondido, CA 92025 I I 760-743-5408 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.30 for 2005 Standards by Enercomp, Inc. I MICROPAS7 v7.30 -------------------------------- File-CASTI2 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP1657 User-Haynal and Company, Inc. ------------------------------------------------------------------------------- Run -Typical House I MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) ---------------------------------- Design Design ---------- Margin = = Space Heating.......... 2.18 ---------- 2.10 - 0.08 = - Space Cooling.......... 73.71 65.62 8.09 = = Water Heating.......... 9.09 9.24 -0.15 = = North Total 84.98 76.96 8.02 = = Space Heating.......... 2.18 2.09 0.09 = = Space Cooling.......... 73.71 67.45 6.26 = = Water Heating.......... 9.09 9.24 -0.15 = = East Total 84.98 78.78 6.20 = = Space Heating.......... 2.18 1.79 0.39 = = Space Cooling.......... 73.71 66.48 7.23 = = Water Heating.......... 9.09 9.24 -0.15 = = South Total 84.98 77.51 7.47 = = Space Heating.......... 2.18 1.75 0.43 = = Space Cooling.......... 73.71 69.17 4.54 = = Water _ Heating.......... 9.09 9.24 -0.15 = = West Total -------- 84.98 ---------------- 80.16 - 4.82 = _ *** Building complies with Computer Performance _ *** HERS Verification Required for Compliance *** _ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2 Project Title.......... Plan 2 Date..07/09/07 14 27 01 MICROPAS7 v7.30 File-CASTI2 Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Conditioned Floor Area..... Building Type .............. Construction Type ......... Fuel Type ................. Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Required 2826 sf Single Family Detached New NaturalGas Cardinal - N,E,S,W 1 1 FullYear Slab On Grade 2 29688 cf 2826 sf 24.7 % of floor area 0.37 Btu/hr-sf-F 0.36 10.5 ft BUILDING ZONE INFORMATION ------------------------- Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ----- ------------- ---------------------- 1 Residence 1513 16558 0.54 2.7 Yes Setback 2.0 Standard No 2 Residence 1313 13130 0.46 2.3 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface ------------ Type (sf) or R-val R-val Azm Tilt Reference Comments 1 ----- ---- ----- ----- ----- --- ---- --- --------- -------------- 1 Wall Wood 156 0.068 13 4 0 90 Yes IV.9 C3 3 Wall Wood 239 0.068 13 4 0 90 No IV.9 C3 To Garage 5 Wall Wood 357 0.068 13 4 180 90 Yes IV.9 C3 7 Wall Wood 296 0.068 13 4 270 90 Yes IV.9 C3 9 Roof Wood 1513 0.025 38 0 n/a 0 Yes IV.1 A18 11 Door Other 21 0.500 0 0 0 90 No IV.5 A4 Garage Door 2 2 Wall Wood 275 0.068 13 4 0 90 Yes IV.9 C3 4 Wall Wood 582 0.068 13 4 90 90 Yes IV A C3 6 Wall Wood 137 0.068 13 4 180 90 Yes IV.9 C3 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3 Projgct Title.......... Plan 2 Date..07/09/07 14:27 01 _--__________________________________________________________________________ MICROPAS7 v7.30 File-CASTI2 Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ ----- ---- ----- ----- ----- --- ---- -------------------------- 8 Wall Wood 185 0.068 13 4 270 90 Yes IV.9 C3 10 Roof Wood 1313 0.025 38 0 n/a 0 Yes IV.1 A18 PERIMETER LOSSES ---------------- Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ --------------------- ------------------------------------ 1 12 S1abEdge 2 13 S1abEdge Orientation 148 0.730 R-0 No IV.26 Al To Outside 143 0.730 R-0 No IV.26 Al To Outside FENESTRATION SURFACES --------------------- 1 1 Door Front (N) 2 Door Front (N) 3 Wind Right (W) 4 Door Back (S) 5 Wind Right (W) 6 Door Back (S) 7 Wind Back (S) 8 Door Right (W) 9 Wind Back (S) 2 10 Wind Front (N) 11 Wind Front (N) 12 Wind Right (W) 13 Wind Front (N) 14 Wind Right (W) 15 Door Right (W) 16 Wind Right (W) 17 Wind Back (S) 18 Wind Back (S) 19 Wind Left (E) 20 Wind Left (E) 21 Wind Left (E) 22 Wind Left (E) Exterior Area U- Act Shade (sf) factor SHGC Azm Tilt Type Location/Comments •---- ----- ----- --- ----------------------------- 24.0 0.360 0.360 0 96.0 0.360 0.360 0 8.0 0.350 0.360 270 64.0 0.360 0.360 180 8.0 0.390 0.360 270 128.0 0.360 0.360 180 32.0 0.350 0.360 180 48.0 0.360 0.360 270 49.5 0.390 0.360 180 8.0 0.390 0.360 0 16.5 0.390 0.360 0 11.0 0.390 0.360 270 21.0 0.390 0.360 0 36.0 0.390 0.360 270 48.0 0.360 0.360 270 10.0 0.390 0.360 270 16.5 0.390 0.360 180 16.5 0.390 0.360 180 8.0 0.390 0.360 90 8.0 0.390 0.360 90 8.0 0.390 0.360 90 14.0 0.390 0.360 90 90 Standard F.3080EN 90 Standard F.4.3080 90 Standard R.2.2020 90 Standard B.8080A 90 Standard R.2040 90 Standard B.2.8080 90 Standard B.2.8020 90 Standard R.6080 90 Standard B.3.3056 90 Standard F.2040 90 Standard F.3056 90 Standard R.2056 90 Standard F.3660 90 Standard R.2.3060 90 Standard R.6080a 90 Standard R.2640 90 Standard B.3056 90 Standard B.3056B 90 Standard L.2040A 90 Standard L.2040B 90 Standard L.2040C 90 Standard L.3640 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 Praject Title.......... Plan 2 Date 07/09/07 14 27 01 MICROPAS7 v7.30 File-CASTI2 Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ 23 Door Left (E) 20.0 0.360 0.360 90 90 Standard L.2680 OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- ----- ----- ------ ----- ------------------------ 1 4 Door 64.0 n/a 8 11 0 n/a n/a 5 Window 8.0 n/a 4 11 0 n/a n/a 6 Door 128.0 n/a 8 15 2 n/a n/a 7 Window 32.0 n/a 2 15 0 n/a n/a 8 Door 48.0 n/a 8 25 0 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ 1 Standard Slab 1513 2 Standard Slab 1313 HVAC SYSTEMS Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type ------------ Systems Efficiency EER or TXV Airflow Draw Capacity 1 ------- ----------- ----- ------------- -------- -------- -------- Furnace 1 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 1 13.00 SEER 11.5 Yes No No No 2 Furnace 1 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 1 13.00 SEER 11.5 Yes No No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5 Project Title.......... Plan 2 Date..07/09/07 14 27 01 _____________________________________________________________________________ MICROPAS7 v7.30 File-CASTI2 Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) 1 ---------- Furnace 25314 n/a n/a n/a ACSplit n/a 30105 37475 n/a 2 Furnace 20672 n/a n/a n/a ACSplit ------------- n/a ---------- 21644 ---------- 26942 n/a Total 45986 51749 ---------- 64417 ---------- n/a Orientation of Maximum..... Front Facing 0 deg (N) Sizing Location............ PALM DESERT Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location ----------- R-value Leakage Area Ducts 1 ------- ------- -------- --------- Furnace Attic R-4.2 Yes No No ACSplit Attic R-4.2 Yes No No 2 Furnace Attic R-4.2 Yes No No ACSplit Attic R-4.2 Yes No No WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Large Gas Recirc/TimeTemp 1 n/a 75 R-12 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6 Project Title.......... Plan 2 Date..07/09/07 14:27:01 MICROPAS7 v7.30 File-CASTI2 Wth-CTZ15S05 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- WATER HEATING SYSTEMS DETAIL Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R-value Light -------------------------------------------------------------------- 1 Large 0.80 n/a 0.032 R- n/a n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a non-standard Water Heating System. HERS REQUIRED VERIFICATION ***Items in this section.require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1 --------------------------------------------------------------------- Project Title.......... Plan 3 Date..07/09/07 14:27:14 'Proj ct Address........ CASTILLA @ GRIFFIN RANCH ******* --------------------- La Quinta *v7.30* I I Documentation Author... Mark Gallant, CEPE/CEA ******* I Building Permit # Haynal and Company, Inc. I I 508 W Mission Ave Ste 201 I Plan Check / Date I Escondido, CA 92025 I I 760-743-5408 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.30 for 2005 Standards by Enercomp, Inc. ---------------------- MICROPAS7 v7.30 File-CASTI3 Wth-CTZ15S05 Program -FORM CF-1R I User#-MP1657 User-Haynal and Company, Inc. Run -Typical House I ------------------------------------------------------------------------------- MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) ---------------------------------- Design Design -------------------- Margin = = Space Heating.......... 2.36 2.02 - 0.34 = = Space Cooling.......... 74.56 64.94 9.62 = = Water Heating.......... 8.16 8.30 -0.14 = = North Total 85.08 75.26 9.82 = = Space Heating.......... 2.36 2.16 0.20 = = Space Cooling.......... 74.56 66.43 8.13 = = Water Heating.......... 8.16 8.30 -0.14 = = East Total 85.08 76.89 8.19 = = Space Heating.......... 2.36 2.21 0.15 = - Space Cooling.......... 74.56 65.17 9.39 = = Water Heating.......... 8.16 8.30 -0.14 = = South Total 85.08 75.68 9.40 = = Space Heating.......... 2.36 2.22 0.14 = - Space Cooling.......... 74.56 65.81 8.75 = = Water _ Heating.......... 8.16 -------- 8.30 -0.14 = = West Total 85.08 ---------------- 76.33 - 8.75 = _ *** Building complies with Computer Performance _ *** HERS Verification Required for Compliance *** _ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 --------------------- Project Title.......... Plan 3 Date..07 09 07 14 27 14 --------------------------- MICROPAS7 v7.30 File-CASTI3 Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 3148 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 2 34531 cf 3148 sf 23.3 % of floor area 0.37 Btu/hr-sf-F 0.36 11 ft BUILDING ZONE INFORMATION ----------------- ------- Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ----- ------------- ---------------------- 1 Residence 1960 22651 0.62 3.1 Yes Setback 2.0 Standard No 2 Residence 1188 11880 0.38 1.9 Yes Setback 2.0 Standard No OPAQUE SURFACES U- --------------- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface ------------ Type ----- (sf) ---- or ----- R-val R-val Azm Tilt Reference Comments 1 ----- ----- --- ---- --- --------- -------------- 1 Wall Wood 232 0.068 13 4 0 90 Yes IV.9 C3 3 Wall Wood 289 0.068 13 4 0 90 No IV.9 C3 To Garage 4 Wall Wood 180 0.068 13 4 270 90 No IV.9 C3 To Garage 5 Wall Wood 164 0.068 13 4 90 90 Yes IV.9 C3 7 Wall Wood 328 0.068 13 4 180 90 Yes IV.9 C3 9 Wall Wood 335 0.068 13 4 270 90 Yes IV.9 C3 11 Roof Wood 1960 0.025 38 0 n/a 0 Yes IV.1 A18 13 Door Other 21 0.500 0 0 0 90 No IV.5 A4 Garage Door 2 2 Wall Wood 164 0.068 13 4 0 90 Yes IV.9 C3 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3 Projgct Title.......... Plan 3------------------------Date__07/09/07 14:27:14 MICROPAS7 v7.30 File-CASTI3 Wth-CTZ15S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 6 Wall ----- Wood ---- 552 ----- 0.068 ----- ----- 13 4 --- 90 ---- 90 --- Yes ----------------------- IV.9 C3 8 Wall Wood 166 0.068 13 4 180 90 Yes IV.9 C3 10 Wall Wood 343 0.068 13 4 270 90 Yes IV.9 C3 12 Roof Wood 1188 0.025 38 0 n/a 0 Yes IV.1 A18 PERIMETER LOSSES Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ --------------------- -------------- ---------------------- 1 14 SlabEdge 209 0.730 R-0 No IV.26 Al To Outside 2 15 S1abEdge 144 0.730 R-0 No IV.26 Al To Outside FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ --------------------- 1 1 Door Front (N) 64.0 0.360 0.360 0 90 Standard F.8080 2 Door Front (N) 24.0 0.360 0.360 0 90 Standard F.3080EN 3 Wind Front (N) 16.0 0.350 0.360 0 90 Standard F.8020 4 Wind Left (E) 8.0 0.390 0.360 90 90 Standard L.2040 5 Door Left (E) 80.0 0.360 0.360 90 90 Standard L.10080 6 Door Right (W) 21.3 0.360 0.360 270 90 Standard R.2880 7 Wind Right (W) 24.0 0.390 0.360 270 90 Standard R.3.2040 8 Door Back (S) 48.0 0.360 0.360 180 90 Standard B.6080 9 Wind Back (S) 44.0 0.390 0.360 180 90 Standard B.8056 10 Door Left (E) 48.0 0.360 0.360 90 90 Standard L.6080 11 Door Back (S) 128.0 0.360 0.360 180 90 Standard B.2.8080 12 Wind Back (S) 32.0 0.350 0.360 180 90 Standard B.2.8020 2 13 Wind Front (N) 16.5 0.350 0.360 0 90 Standard F.3056 14 Wind Front (N) 10.0 0.350 0.360 0 90 Standard F.2050 15 Wind Right (W) 15.0 0.390 0.360 270 90 Standard R.3050 16 Door Right (W) 24.0 0.360 0.360 270 90 Standard R.3080 17 Wind Right (W) 8.0 0.390 0.360 270 90 Standard R.2040 18 Wind Back (S) 44.0 0.390 0.360 180 90 Standard B.8056A 19 Wind Left (E) 24.0 0.390 0.360 90 90 Standard L.3.2040 20 Wind Left (E) 16.0 0.390 0.360 90 90 Standard L.2.2040 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 Project Title.......... Plan 3 Date..07 09 07 14 27 14 MICROPAS7 v7.30 File-CASTI3 Wth-CT215S05 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ----------------- 21 Wind Left (E) 30.0 0.390 0.360 90 90 Standard L.2.3050 22 Wind Left (E) 8.0 0.390 0.360 90 90 Standard L.2040a OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- ----- ----- ------ ----- ------------------------ 1 4 Window 8.0 n/a 4 9 1 n/a n/a 5 Door 80.0 n/a 8 9 1 n/a n/a 10 Door 48.0 n/a 8 27 1 n/a n/a 11 Door 128.0 n/a 8 27 2 n/a n/a 12 Window 32.0 n/a 2 27 0 n/a n/a 2 16 Door 24.0 n/a 8 24 1 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ----- 1 Standard Slab 1960 2 Standard Slab 1188 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type ------------ Systems Efficiency EER or TXV Airflow Draw Capacity 1 ------- ----------- ----- ------------- -------- -------- -------- Furnace 1 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 1 13.00 SEER 11.5 Yes No No No 2 Furnace 1 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 1 13.00 SEER 11.5 Yes No No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5 ' Project Title.......... Plan 3 Date..07/09/07 14:27:14 � ------------ MICROPAS7 v7.30 File-CASTI3 Wth-CTZ15S05 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) 1 ---------- Furnace 32944 n/a n/a n/a ACSplit n/a 34272 42662 n/a 2 Furnace 19356 n/a n/a n/a ACSplit ------------- n/a ---------- 17075 ---------- 21255 n/a Total 52300 51347 ---------- 63917 ---------- n/a Orientation of Maximum..... Front Facing 90 deg (E) Sizing Location............ PALM DESERT Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location ----------- R-value Leakage Area Ducts 1 ------- ------- -------- --------- Furnace Attic R-4.2 Yes No No ACSplit Attic R-4.2 Yes No No 2 Furnace Attic R-4.2 Yes No No ACSplit Attic R-4.2 Yes No No WATER HEATING SYSTEMS --------------------- Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Large Gas Recirc/TimeTemp 1 n/a 75 R-12 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6 ----------- Pr�oject Title.......... Plan 3 Date..07 09 07 14 27 14 MICROPAS7 v7.30 File-CASTI3 Wth-CTZ15S05 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ------------------------------------------------------------------------------- WATER HEATING SYSTEMS DETAIL Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency ------------------------ Input ------------ Fraction ---------- R-value Light --------------- 1 Large 0.80 n/a 0.032 ------- R- n/a n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a non-standard Water Heating System. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary.