Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PGA West Signature - The Estates TR 36537 BTCP2016-0002 (Plans 1-3)
Bin, # .0ty Of La Quin td Building 8z Safety Dlvislon P.O. Box 1504,'78.495 Calle Tampko La.Quinta, CA 92253 • (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: Owner's Name:. R R E F I I— C W C L a Q, L L C, A.P.Number.. Address: 5927 Priestly Dr. , Suite 11 ----------------- Legal Description: City, ST, zip: Carlsbad, CA 92008 Contractor. California West Construet-i nTelephone: Address: 5927 Priestly Dr. Ste 110 Project Description: CIty,ST,zip: 'Carlsbad CA 92008 Telephone: 7 6 0 918 — 2 8 2 State Lic. # : City Lia #; Arch., angr., Designer: B a s s L a R o n i Address: City.,ST,zip: Newport Beach, CA,' 92660 Telephone: ( 9 4 9) 553-91C State Lic. #: Name of Contact Person: Mary Nettles Construction Type:. Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ff.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Regld Reed TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amouut Structural Cafes, Reviewed, ready for corrections Plan Check Deposit, . Truss Calcs. Called Contact Person Plan Check Balance Title 24 Coles. Plans picked up Construction Flood plain plan Plans resubmitted.. Mechanical G•radingplan r! Review, ready for correctionslissue Electrical Subcontactor List Called Contort person plumbing Grant Deed Plana picked up S.M.I. H.O.A. Approval Plans resubmitted Grading 10 U011.SE:- ''' Reylew, ready for correctionskssue Developer Impart Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit Issue School Fees Total Permit Fees March 16, 2015 Spates Fabricators, Inc. 85 — 435 Middleton Street Thermal, CA 92274 To Whom It May Concern, Timber Products Inspection, Inc. is proud to announce that the following truss manufacturing facility, Spates Fabricators, Inc. is a subscriber to our nationally accredited "Truss Quality Auditing Program". The TP Truss Quality Auditing Program is accredited under the IAS AA696 Evaluation Report and conforms to requirements for independent inspection of trusses under the International Building Code and International Residential Code. The TP program involves daily in -plant quality control checks by plant personnel and periodic unannounced inspections by TP personnel for conformance to engineering and industry standards for fabricators. The TP quality stamp on each truss bearing the registered GTI log is your assurance that the trusses were fabricated in accordance with the TP Truss Quality Auditing Program and applicable sections of the IBC and IRC. Specific design loads and installation requirements are not covered by the TP Auditing Program. At present, Spates Fabricators Inc. is in good standing and the program is set to be renewed in 2016. Please note that the quality programs are automatically renewed unless requested otherwise. Any questions about this program, the facilities status in the program or the use of the TP registered quality stamps may be directed to Timber Products Inspection, Inc. at (770) 922-8000. Sincerely, Timber Products Inspection Patrick C. Edwards, P.E. Director of Engineering P.O.Box 919 • 1641 Sigman Road • Conyers, Georgia 30012 • 770/922-8000 • FAX: 770/922-1290 105 S.E. 124th Avenue • Vancouver, WA 98684. 360/449-3138 • FAX: 360/449-3953 DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES SECTION: 0617 53—SHOP-FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK INDUSTRIES, INC. 14515 NORTH OUTER FORTY, SUITE 300 CHESTERFIELD, MISSOURI 63017 EVALUATION SUBJECT: MITEK° TRUSS CONNECTOR PLATES: TL18, MT18, MTI8HSTM, M18SHSTM TL20 AND MT20 ICC ICC a ICC c �.. PMG LISTED Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPQ Award in Excellence" A Subsidiary of CODECCOUNca ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. "°nop Copyright 0 2014 IMES Evaluation Report ESR-1988 Reissued October 2014 This report is subject to renewal December 2016. vwwv.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 06 00 00-WOOD, PLASTICS AND COMPOSITES Section: 06 17 53-Shop-Fabricated Wood Trusses REPORT HOLDER: MITEK INDUSTRIES, INC. 14515 NORTH OUTER FORTY, SUITE 300 CHESTERFIELD, MISSOURI 63017 (314) 434-1200 www.mii.com EVALUATION SUBJECT: MiTek® TRUSS CONNECTOR PLATES: TL18, MT18, MT18HSTM, M18SHSM, TL20 and MT20 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2012, 2009 and 2006 International Building Code (IBC) ■ 2012, 2009 and 2006 International Residential Code (IRC) ■ 1997 Uniform Building CodeTM (UBC) Property evaluated: Structural 2.0 USES MiTek® metal truss connector plates are used as joint connector components of light wood -frame trusses. 3.0 DESCRIPTION 3.1 MiTek®TL18 and MT18: Models TL18 and MT18 metal truss connector plates are manufactured from minimum No. 18 gage [0.0466 inch total thickness (1.18 mm)], ASTM A653 SS, Grade 40 steel, with a G60 galvanization coating [0.0005 inch thickness on each side (0.013 mm)] and having a base -metal thickness of 0.0456 inch (1.16 mm). The plates have teeth 3/8 inch (9.5 mm) long, punched in pairs formed at right angles to the face of the parent metal so that two teeth per hole occur along the length. The spacing along the longitudinal direction of each punched slot is 1 inch (25.4 mm) on center. The transverse centerlines of adjacent slots are staggered 0.10 inch (2.54 mm). The distance between longitudinal centerlines of the slots is 0.25 inch (6.35 mm). There are eight teeth per square inch (645 mm2) of surface area. Plates are available in 1/2-inch (12.7 mm) width increments, up to 12 inches (304.8 mm), and lengthwise in 1-inch (25.4 mm) multiples. See Figure 1 for details. 3.2 MiTek® MT18HSTm: Model MT18HSTM metal truss connector plates are manufactured from minimum No. 18 gage [0.0466 inch total thickness (1.18 mm)], ASTM A653, Grade 60, high -strength, low -alloy steel (HSLAS) with a G60 galvanization coating [0.0005 inch thickness on each side (0.013 mm)] and having a base -metal thickness of 0.0456 inch (1.16 mm). The plate has teeth 3/8 inch (9.5 mm) long, punched in pairs formed at right angles to the face of the parent metal so that two teeth per hole occur along the length. The spacing along the longitudinal direction of each punched slot is 1 inch (25.4 mm) on center. The transverse centerlines of adjacent slots are staggered 0.10 inch (2.54 mm). The distance between longitudinal centerlines of the slots is 0.25 inch (6.35 mm). There are eight teeth per square inch (645 mm2) of surface area. Plates are available in 1/2-inch (12.7 mm) width increments, up to 12 inches (304.8 mm), and lengthwise in 1-inch (25.4 mm) multiples. See Figure 1 for details. 3.3 MiTeV M18SHSTm: Model M18SHSTM metal truss connector plates are manufactured from minimum No. 18 gage [0.0466-inch (1.18 mm) total thickness], hot -dipped galvanized steel that meets the requirements of ASTM A653 SS, Grade 80 steel, with a G60 galvanization coating [0.0005 inch thickness on each side (0.013 mm)] and having a base metal thickness of 0.0456 inch (1.16 mm). The plates have 3/8-inch-long (9.5 mm) teeth, punched in pairs formed at right angles to the face of the parent metal so that two teeth per hole occur along the length. The spacing along the longitudinal direction of each punched slot is 1 inch (25.4 mm) on center. The transverse centerlines of adjacent slots are staggered 0.10 inch (2.54 mm). The distance between longitudinal centerlines of slots is 0.25 inch (6.35 mm). There are eight teeth per square inch (645 mm2) of surface area. Plates are available in 1/2-inch- width (12.7 mm) increments, up to 12 inches (304.8 mm), and lengthwise in 1-inch (25.4 mm) multiples. See Figure 1 for details. 3.4 MiTek® TL20 and MT20TM: Models TL20 and MT20M metal truss connector plates are manufactured from minimum No. 20 gage [0.0356 inch total thickness (0.9 mm)], ASTM A653 SS, Grade 40 steel, with a G60 galvanization coating [0.0005 inch thickness on each side (0.013 mm)) and having a base -metal thickness of 0.0346 inch (0.88 mm). The plates have teeth 3/8 inch (9.5 mm) long, punched in pairs formed at right angles to the face of the parent metal so that two teeth per hole occur along the length. The spacing along the longitudinal direction of each punched slot is 1 inch (25.4 mm) on ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as gn lml to any finding or other matter in this report, or as to any product covered by the report. emu n Copyright 0 2014 Page 1 of 3 ESR-1988 I Most Widely Accepted and Trusted Page 2 of 3 center. The transverse centerlines of adjacent slots are staggered 0.10 inch (2.54 mm). The distance between longitudinal centerlines of the slots is 0.25 inch (6.35 mm). There are eight teeth per square inch (645 MM2) of surface area. Plates are available in '/z-inch width (12.7 mm) increments, up to 12 inches (304.8 mm), and lengthwise in 1-inch (25.4 mm) multiples. See Figure 1 for details. 4.0 DESIGN AND INSTALLATION 4.1 General: All truss plates are pressed into the wood for the full depth of their teeth by hydraulic -platen embedment presses, multiple roller presses that use partial embedment followed by full -embedment rollers, or combinations of partial embedment roller presses and hydraulic -platen presses that feed trusses into a stationary finish roller press. Trusses must be assembled within the tolerances provided by the Truss Plate Institute's Quality Criteria for the Manufacture of Metal Plate Connected Wood Trusses, shown as Chapter 3 in ANSI/TPI 1 National Design Standard for Metal Plate Connected Wood Truss Construction. 4.2 Allowable Design Values: Allowable design values for MiTek® metal truss connector plates to be used in the design of metal plate connected wood roof and floor trusses are shown in Tables 1 and 2. Allowable design values are applicable when the connection is made with identical plates on opposite sides of the joint. This evaluation report is limited to the evaluation of connection capacity of the MiTek® metal truss connector plates listed in this report. The design, manufacture, and installation of trusses employing the truss plates have not been evaluated. 5.0 CONDITIONS OF USE The MiTek® Industries metal truss connector plates described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 This evaluation report and the manufacturer's published installation instructions, when required by the code official, must be submitted at the time of permit application. In the event of a conflict between the manufacturer's published installation instructions and this document, the instructions in this document govern. 5.2 Each application for a building permit, using these truss plate connectors, must be accompanied by documentation showing that the design, manufacture, and proposed installation conform with the requirements of the applicable code. 5.3 This report establishes plate design values only. For items not covered by this report, such as truss design, fabrication, quality assurance and special inspection, refer to ANSI/TPI 1, engineering drawings and the applicable code. 5.4 The design values (lateral resistance values, effective tension strength ratios, and effective shear resistance ratios) used in the design of trusses, using MiTek® Industries metal truss connector plates, must not exceed those listed in Tables 1 and 2 of this report. Load combination reductions must be in accordance with the applicable code. 5.5 All lumber used in the fabrication of trusses using MiTek® Industries metal truss connector plates must be graded in compliance with the applicable building code, and must have a moisture content not exceeding 19 percent at the time of assembly. Wet service factors from ANSI/TPI 1 Section 6.4.6 must be applied to the table values when the lumber moisture content exceeds 19 percent. Allowable values shown in the tables of this report are not applicable to metal connector plates embedded in either fire -retardant - treated lumber or preservative -treated lumber. 5.6 Metal truss connector plates must be installed in pairs on opposite faces of truss members. 5.7 Galvanized G60 metal truss plate connectors subject to corrosive environments must be protected in accordance with Section 6.5 of ANSI/TPI 1. 5.8 MiTek® metal truss connector plates are manufactured in St. Charles, Missouri; Tolleson, Arizona; Tampa, Florida; Edenton, North Carolina; and Bradford, Ontario, Canada. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the National Design Standard for Metal Plate Connected Wood Truss Construction, ANSI/TPI 1- 2007. 6.2 Manufacturer's descriptive literature. 6.3 A quality control manual. 7.0 IDENTIFICATION The MiTek® connectors are identified by an imprint of the plate name embossed into the surface of the plate (for example, the MT20TM plate is embossed "MT20"). Additionally, boxes containing the connector plates must be labeled with the MiTek® Industries name, the metal connector plate model, and the evaluation report number (ESR-1988). TABLE 1-ALLOWABLE LATERAL RESISTANCE VALUES, HYDRAULIC -PLATEN EMBEDMENT (lb/in2/PLATE) LUMBER SPECIES SG AA EA AE EE TL18, MT18, MT18HSTM, M18SHSTM, TL20 and MT20TM Douglas fir -larch 0.49 248 203 170 171 Hem -fir 0.43 188 159 133 141 Spruce -pine -fir 0.42 206 162 125 122 Southern pine 0.55 244 192 171 178 For 51: 1IWO- = 6.9 kPa. NOTES: 'Tooth -holding units = psi for a single plate (double for plates on both faces when applying to area on only one face). To achieve values, plates must be installed on opposite sides of joint. AA = Plate parallel to load, wood grain parallel to load. EA = Plate perpendicular to load, wood grain parallel to load. AE = Plate parallel to load, wood grain perpendicular to load. EE = Plate perpendicular to load, wood grain perpendicular to load. 3All truss plates are pressed into the wood for the full depth of their teeth by hydraulic -platen embedment presses, multiple roller presses that use partial embedment followed by full -embedment rollers, or combinations of partial -embedment roller presses and hydraulic -platen presses that feed trusses into a stationary finish roller press. ESR-1988 I Most Widely Accepted and Trusted Page 3 of 3 TABLE 2-EFFECTIVE TENSION AND SHEAR RESISTANCE ALLOWABLE DESIGN VALUES' PROPERTY FORCE DIRECTION TL18 AND MT18 MT18HSTM M18SHSTM TL20 AND MT20TM Efficiency Pounds/ inch/Pair of Connector Plates Efficiency Pounds/ inch/Pair of Connector Plates Efficiency Pounds/ inch/Pair of Connector Plates Efficiency Pounds/ inch/Pair of Connector Plates Tension values in accordance with Section 5.4.4.2 of TPI-1 (Minimum Net Section over the joint)Z Tension @ 01 0.5 1149 0.48 1596 0.52 2247 0.49 857 Tension @ 90, 0.52 1208 0.5 1671 0.53 2292 0.49 854 Tension values in accordance with TPI-1 with a deviation [see Section 5.4.9 (e)] (Maximum Net Section Occurs over the joint) Tension @ 0° 0.59 1349 0.59 1975 0.6 2586 0.59 1035 Tension @ 900 0.53 1214 0.51 1727 0.54 2341 0.49 E861 Shear Values Shear @ 00 0.56 874 0.55 1099 0.53 1363 0.51 604 Shear @ 300 0.66 1023 0.57 1153 0.57 1482 0.74 876 Shear @ 60' 0.83 1283 0.74 1492 0.7 1805M 970 Shear @ 900 0.49 757 0.52 1052 0.39 1012686 Shear @ 120' 0.39 608 0.4 802 0.41 1073498 Shear @ 150' 0.45 702 0.37 745 0.33 868592 For SI: 1 lb/inch = 0.175 N/mm, 1 inch = 25.4 mm. NOTES: 'Minimum coated thickness is 0.0356 inch (0.904 mm) for 20 gage, or 0.0466 inch (1.184 mm) for 18 gage in accordance with Section 4.3.4 of ANSI/TPI 1. Minimum coating thickness for G60 is 0.0010 inch (0.025 mm) total for both sides in accordance with Sections 4.3.3.2 and 6.3.4.1.3 of ANSI/TPI 1. 2Minimum Net Section - A line through the plate's tooth pattern with the minimum amount of steel for a specified orientation. For these plates, this line passes through a line of holes. 3Maximum Net Section - A line through the plate's tooth pattern with the maximum amount of steel for a specified orientation. For these plates, this line passes through a section of the plate with no holes. 0.125" 0.250" 0.125" 0.375`" 32 mm 6.4 mm 3.2 mm 4 u; WIDTH MT18, TL18, MT18HS, M18SHS, MT20, TL20 FIGURE 1-APPROXIMATE DIMENSIONS OF MITEK CONNECTOR PLATES (inches) (1 inch = 25.4 mm) IMES Evaluation Report ESR-1988 FBC Supplement Reissued December 2014 This report is subject to renewal December 2016 wwwJcc-es.orq 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES Section: 06 17 53—Shop-Fabricated Wood Trusses REPORT HOLDER: MITEK INDUSTRIES 14515 NORTH OUTER FORTY, SUITE 300 CHESTERFIELD, MISSOURI 63017 (314) 434-1200 www.mii.com EVALUATION SUBJECT: MiTek°TRUSS CONNECTOR PLATES: TL18, MT18, MTI8HSTM, M18SHSTM, TL20 AND MT20 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that MiTek® Truss Connector Plates TL18, MT18, MT18HST"' M18SHSTM, TL20 and MT20, recognized in ICC-ES master report ESR-1988, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2010 and 2007 Florida Building Code —Building ■ 2010 and 2007 Florida Building Code —Residential 2.0 CONCLUSIONS The MiTek® Truss Connector Plates TL18, MT18, MT18HSTM, M18SHSTM, TL20 and MT20, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1988, comply with the 2010 and 2007 Florida Building Code —Building and the 2010 and 2007 Florida Building Code —Residential, provided the design and installation are in accordance with the International Building Code (IBC) provisions noted in the master report. Use of the MiTek® Truss Connector PlatesTL18, MT18, MT18HSTM, M18SHSTM, TL20 AND MT20 has also been found to be in compliance with the High -Velocity Hurricane Zone provisions of the 2010 and 2007 Florida Building Code —Building and the 2010 and 2007 Florida Building Code —Residential. For products falling under Florida Rule 9N-3, verification that the report holder's quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report reissued December 2014. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. m¢eurnsu .. [40[MUMtlP Copyright 0 2014 Page 1 of 1 IMES Evaluation Report ESR-1988 CBC Supplement Reissued December 2014 This report is subject to renewal December 2016. wwwkc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES Section: 06 17 53—Shop-Fabricated Wood Trusses REPORT HOLDER: MITEK INDUSTRIES, INC. 14615 NORTH OUTER FORTY, SUITE 300 CHESTERFIELD, MISSOURI 63017 (317) 434-1200 www.mii.com EVALUATION SUBJECT: Mitek® TRUSS CONNECTOR PLATES: TL18, MT18, MT18HSTM' M18SHS rm, TL20 AND MT20 1.0 EVALUATION SCOPE Compliance with the following code: 2010 California Building Code (CBC) Property evaluated: Structural 2.0 PURPOSE OF THIS SUPPLEMENT This supplement is issued to indicate that the Mitee Truss connector plates TL18, MT18, MT18HSTm, M18SHSTm, TL20 and MT20, described in the master report ESR-1988 comply with the 2010 California Building Code, Chapters 16, 16A, 17, 17A, and 23, when design and installation are in accordance with the IBC provisions described in the master evaluation report and with Chapters 16, 16A, 17, 17A, and 23 of the 2010 California Building Code. This supplement expires concurrently with the master evaluation report reissued December 2014. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed --i as an endorsement of the subject of the report or a recommendation far its use. There is no warranty by ICC Evaluation Service. LLC, express or implied as IIIiI to any finding or other matter in this report, or as to any product covered by the report w rvmmxu mcemuxuc Copyright © 2014 Page 7 of 1