Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PGA West Signature - The Estates TR 36537 BTCP2016-0002 (Plans 1-3) Revision 1 - Title 24
Title 24 Energy Report The Estates at PGA West Plan 3 and 3 w/Bedroom 3 Option La Quinta Z013 Building Energy Efficiency Standards HEG Project No.: 14023U Revised Report: Delta 3 California West Construction Bassenian Lagoni Architects Heritage Energy Group, LLC February 23, 2016 Tel: (949) 789-7221 / Fax: (949) 789-7222 6 APR 0,5 2016 CITY OF LA QUIN7A COMMUNITY DEVELOPMENT .1 sr �rI 0 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 13:53, Wed, Mar 23, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CF1 R-PRF-NCB-01 Page 1 of 11 GENERAL INFORMATION 01 Project Name Plan 3 02 Calculation Description Title 24 Analysis 03 Project Location 04 A City la quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-2 (595c) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 2899 15 Number of Zones 1 16 Slab Area (FT2) 2528 17 Number of Stories 2 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 Glazing Percentage (%) 30.7% Detailed help on using the CF-1 R Certificate of Compliance is available via the Internet by either. r ' scanning`mithe QR code or -browsing to http://www.title24ennergycode.org/t24heID/cfl r.aspx w R ❑� COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-NO11187OA-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:02:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Description: Title 24 Analysis Calculation Date/Time: 13:53, Wed, Mar 23, 2016 Input File Name: 14023P3U.xml CF1 R-PRF-NCB-01 Page 2 of 11 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 2.92 3.36 -0.44 -15.1 % Space Cooling 112.34 115.38 -3.04 -2.7% IAQ Ventilation 0.91 0.91 0.00 0.0% Water Heating 9.75 5.03 4.72 48.4% PV Credit ---- 0.00 0.00 ---- North Facing - TOTAL 125.92 124.68 1.24 1.0% Space Heating 2.92 4.01 -1.09 -37.3% Space Cooling 112.34 110.37 1.97 1.8% IAQ Ventilation 0.91 0.91 0.00 0.0% Water Heating 9.75 5.03 4.72 48.4% PV Credit ---- 0.00 0.00 ---- East Facing - TOTAL 125.92 120.32 5.60 4.4% Space Heating 2.92 4.41 -1.49 -51.0% Space Cooling 12.34 ; 0.91� i' '';:= r"-"112:40°-a n -0.06 ' 0.91 f i { r / 0.00 -0.1% 0.0% IAQ Ventilation : + i_y� ",9.75,,','�_. � 5.03 �. t. 4.72 48.4% Water Heating 9 � lti i i j'{ lft r�-s PV Credit Ez /� R0.0'L� if t `t 0.00 South Facing - TOTAL 125.92 122.75 3.17 2.5% Space Heating 2.92 3.26 -0.34 -11.6% Space Cooling 112.34 106.61 5.73 5.1 % IAQ Ventilation 0.91 0.91 0.00 0.0% Water Heating 9.75 5.03 4.72 48.4% PV Credit ---- 0.00 0.00 ---- West Facing - TOTAL 125.92 115.81 10.11 8.0% Registration Number: 216-NO11187OA-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:02:26 • CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 13:53, Wed, Mar 23, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins CF1 R-PRF-NCB-01 Page 3of11 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 3 2899 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 living Conditioned HVAC System1 2899 10.1 DHW Sys 1 Registration Number: 216-NO11187OA-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-03-23 14:02:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 13:53, Wed, Mar 23, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CF1 R-PRF-NCB-01 Page 4 of 11 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ftZ) Window Area (ftZ) Tilt(deg) Front Wall living R-19 Wall 0 Front 364 52.528 90 Left Wall living R-19 Wall 90 Left 485 30 90 Rear Wall living R-19 Wall 180 Back 566 72 90 Right Wall living R-19 Wall 270 Right 737 69 90 garage wall living R-19 Wall 0 Front 100 0 90 Front Wa112 living R-19 Wall 0 Front 192 37.5 90 Left Wa112 living R-19 Wall 90 Left 737 148 90 Rear Wa112 living R-19 Wall 180 Back 404 283.995 90 Right Wa112 living R-19 Wall 270 Right 737 198 90 garage wall2 living R-19 Walll 0 Front 100 0 90 Roof living R-38 Roof Attic RB 393 Roof2 living R-38 Roof Attic RB 2224 Exterior WallR Garage r Garage Ext Wally 270 Right 'Fron 270 0 90 Exterior Wall Garage e Garage Ext Wall f `--D. ( l 323 0 90 Exterior W8111- Garage W > Garage Ext Wall° r ',�— 90 Left` ` ) 293 0 90 Exterior Wall Garage. �— '-{Garage Ext Wall 4--( x -,t '180 !Backe{ 10 0 90 Roofg Garage R-0 Roof Attic 519 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 5 0.1 0.85 Yes No Registration Number: 216-NO11187OA-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:02:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD . Project Name: Plan 3 Calculation Description: Title 24 Analysis Calculation Date/Time: 13:53, Wed, Mar 23, 2016 Input File Name: 14023P3U.xml CF1 R-PRF-NCB-01 Page 5 of 11 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height (ft) Width(ft ) Multiplie r Area (ft) U- factor SHG C Exterior Shading 3050-2 Window Front Wall (Front-0) 8.0 6.0 0.625 30.0 0.34 0.22 3076 frdr Window Front Wall (Front-0) 8.0 8.0 0.352 22.5 0.35 0.25 3080-1 frdr Window Left Wall (Left-90) 8.0 6.0 0.5 24.0 0.35 0.25 2030 Window Left Wall (Left-90) ---- ---- 1 6.0 0.34 0.22 9080 frdr Window Rear Wall (Back-180) ---- ---- 1 72.0 0.35 0.25 2060-2 Window Right Wall (Right-270) ---- ---- 1 24.0 0.34 0.22 3050-3 Window Right Wall (Right-270) ---- ---- 1 45.0 0.34 0.22 9080- stack Window Front Wa112 (Front-0) ---- ---- 1 25.0 0.34 0.22 2626--2 Window Front Wa112 (Front-0) ---- ---- 1 12.5 0.34 0.22 3080 Window Left W6112 (Left-90) 5.0 5.0 0.72 18.0 0.35 0.25 4060-2 Window Left Wal12 (Left-90) ---- ---- 1 48.0 0.34 0.22 4020-2 Window r- Left Wa112 (Left-90) ,___� �,� _ ---- ---- 1 4.0 0.34 0.22 3040 2 Window r Left Wa112 (L'eft 90) ' t ' f f ` 5.0 f 5:0 �70.96 24.0 0.34 0.22 2040-2 Window _L6ft-Wa112 (Left-90) ! 5 - J 15.0 , l`1 2 30.0 0.34 0.22 3020 Window , Left Wa112 (Left,90) f-y r 5.0 �" %5.Oy-A.24 6.0 0.34 0.22 3060 Window "Left Wa112 (Left=90) ` ' `- ` 1 18.0 0.39 0.29 3060-2 Window Rear Wa112 (Back-180) ---- ---- 1 36.0 0.34 0.22 3020-2 Window Rear Wa112 (Back-180) 3.0 3.0 1.333 12.0 0.34 0.22 6020 Window Rear Wa112 (Back-180) ---- ---- 1 12.0 0.34 0.22 16080 Window Rear Wall2 (Back-180) 3.0 3.0 14.222 128.0 0.34 0.22 3020-4 Window Rear Wa112 (Back-180) 8.0 8.0 0.375 24.0 0.34 0.22 3080-3 frdr Window Rear Wall2 (Back-180) 8.0 8.0 1.125 72.0 0.35 0.25 2060-2 2 Window Right W8112 (Right-270) ---- ---- 1 24.0 0.34 0.22 2020-2 Window Right Wa112 (Right-270) ---- ---- 1 8.0 0.34 0.22 20302 Window Right Wa112 (Right-270) ---- ---- 1 6.0 0.34 0.22 4050 Window Right Wa112 (Right-270) ---- ---- 1 20.0 0.34 0.22 2050-2 Window Right Wa112 (Right-270) ---- ---- 1 20.0 0.34 0.22 9080 ddr Window Right Wa112 (Right-270) ---- - 1 72.0 0.34 0.22 3080-2 frdr Window Right Wa112 (Right-270) 8.0 6.0 1 48.0 0.35 0.25 Registration Number: 216-NO11187OA-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:02:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 13:53, Wed, Mar 23, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CF1 R-PRF-NCB-01 Page 6 of 11 DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door Right Wa112 28.0 0.50 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 3050-2 10 1 6 6 0 0 0 0 0 0 0 0 0 3076 frdr 10 1 6 6 0 0 0 0 0 0 0 0 0 3080-1 frdr 6 1 4 4 0 0 0 0 0 0 0 0 0 3080 0 0 0 0 0 0 0 0 0 0 0 0 0 3040 --- 2 0 0 0 0 0 0 0 0 0 0 0 0 0 2040-2 0 0 r!0 ,. 0, r-'0' _ �0 � 0" 0 0 0 0 0 0 3020 0 0 / 0 t r a j 10 t z 0 ��s 0 tv� 0'. n 0 0 0 0 0 0 3020-2 2 ti `.s °, 2 r 2} i.2 i` r 0 01 0 0 0 0 0 0 16080 12 1 .10 _ i s10� t.0 �.� r,. 0 U 1 0--N - Or-)0 0 0 0 0 3020-4 12 1 10 `' `10--' .0 `'0 ` 0'` 0` 0 0 0 0 0 3080-3 frdr 2 2 2 2 0 0 0 0 0 0 0 0 0 3080-2 frdr 10 1 6 6 0 0 0 0 0 0 0 0 0 Registration Number: 216-NO11187OA-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:02:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 13:53, Wed, Mar 23, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CF1 R-PRF-NCB-01 Page 7 of 11 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic floor - Cavity: - no insulation - Sheathinglnsulation - no sheathingfinsul. - R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathingfinsul. - Cavity: R 19 Sheathing/Insulation: - no sheathinglnsul. - R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Attic Floor: - no attic floor - Cavity: R 38 SheathingInsulation - no sheathingfinsul. - R-38 Roof Attic RB Ceilings (below attic) r Wood Framed Ceiling _ 2x4 @ 24 iw O.0 r" R 38 Inside Finish: Gypsum Board { C r =e �� 1� • ` Inside Finish: Gypsum Board ` - , - _., ,i ,; f %� • \,- Sheathing/Insulation: - no sheathinglnsuL - �% f.../ Cavity: R 19 c^; Sheathing/Insulation: - no sheathingfinsul - R-19 Walll Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathinglinsuf - Cavity: - no insulation (vertical) - no insulation Sheathing/Insulation: - no sheathinglinsul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. (vertical) - Exterior Finish: 3 Coat Stucco SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab living 304 40 None 0.8 No Slab2 living 2224 255 None 0.8 No Slab -on -Grade Garage 519 122 None 0 No Registration Number: 216-NO11187OA-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:02:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 13:53, Wed, Mar 23, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CFI R-PRF-NCB-01 Page 8 of 11 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED REQUIRED 1464.0 WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Standard 1 0.0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0 0.95 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02, C i 03 -_:` iO4. } 1. !r"05 06 07 Name -. �, ` Pipe Insulation �� t �'• I E ~= " Parallel Piping 0 1r l i / - (Compact Distribution, -• '` _- --Point-of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n`/a - -` n/a 61a n/a HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC System1 Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 2899 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 216-NO11187OA-000000000-0000 Registration Date/Time:2016-03-23 16:10:53 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:02:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 13:53, Wed, Mar 23, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CF1 R-PRF-NCB-01 Page 9 of 11 HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 12.5 15 Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Not Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in unconditioned Sealed and tested f — 6 r�'-� t� —Attic r Attic None Air Distribution System 1-hers-dist attic t. li fl-'II I`kl I I \A tl 111 11 II; HVAC DISTRIBUTION - HERS VERIFICATION 01 02 s' ,.' e i :1 03 It"'Ft V I L.,; >C_ r04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dirt Required 6.0 Not Required Not Required Not Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 Registration Number: 216-NO11187OA-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-03-23 14:02:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 13:53, Wed, Mar 23, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CF1 R-PRF-NCB-01 Page 10 of 11 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 59 Exhaust 0 Required COOLING VENTILATION NONE 0 V- D '. k ._ _ ( Registration Number: 216-NO11187OA-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-03-23 14:02:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 13:53, Wed, Mar 23, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CFI R-PRF-NCB-01 Page 11 of 11 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Rudy Sains Company: Signature Date: Heritage Energy Group 2016-03-23 16:09:12 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949-584-1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency -for approval with this building permit application. Responsible Designer Name: �t f I + ResponsibleDesigner Signature:-, /,7-? Dave Warren Company: Date Signed: q ` ; r—w t- ; € i '%/ California West Communities 2016-03-23 16:10:53 Address: License: 5927 Priestly Drive, Suite 103 N/A City/State/Zip: Phone: Carlsbad, CA 92008 760-918-2824 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-NO11187OA-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:02:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-NCB-01 Project Name: Plan 3 Calculation Description: Title 24 Analysis Calculation Date/Time: 14:46, Wed, Mar 23, 2016 Input File Name: 14023P3UOPTxml Page 1 of 11 GENERAL INFORMATION 01 Project Name Plan 3 02 Calculation Description Title 24 Analysis 03 Project Location 04 A City la quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-2 (595c) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 2899 15 Number of Zones 1 16 Slab Area (FT2) 2528 17 Number of Stories 2 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 Glazing Percentage (%) 30.3% Detailed help on using the CF-1 R Certificate of Compliance is available via the Internet by eithe '_� r scanning the QR code or,browsing to _' http://www.title24energycode.org/t24help/cfl r.aspx +�-^�, .— f1 .a r R O V I D E *. ❑ COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-No111859A-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:56:03 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Description: Title 24 Analysis Calculation Date/Time: 14:46, Wed, Mar 23, 2016 Input File Name: 14023P3UOPTxml CF1 R-PRF-NCB-01 Page 2 of 11 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 2.82 3.08 -0.26 -9.2% Space Cooling 111.00 115.10 -4.10 -3.7% IAQ Ventilation 0.91 0.91 0.00 0.0% Water Heating 9.75 5.03 4.72 48.4% PV Credit ---- 0.00 0.00 ---- North Facing - TOTAL 124.48 124.12 0.36 0.3% Space Heating 2.82 3.61 -0.79 -28.0% Space Cooling 111.00 110.05 0.95 0.9% IAQ Ventilation 0.91 0.91 0.00 0.0% Water Heating 9.75 5.03 4.72 48.4% PV Credit ---- 0.00 0.00 ---- East Facing - TOTAL 124.48 119.60 4.88 3.9% Space Heating 2.82 4.39 -1.57 -55.7% Space Cooling 11.1 00 ^ r-""112.76=(7 r -1.76 ' �--' -1.6% IAQ Ventilation .�-s, 0.91 0.91 i i 0.00 0.0% Water Heating �� 9:75; �- V5.03 y'� I; PV Credit _ =._ R +�' P R'0.00 �-^y 0.00 -- South Facing TOTAL ~ 124.48 123.09 i/ 1.39 1.1% - Space Heating 2.82 3.26 -0.44 -15.6% Space Cooling 111.00 105.18 5.82 5.2% IAQ Ventilation 0.91 0.91 0.00 0.0% Water Heating 9.75 5.03 4.72 48.4% PV Credit ---- 0.00 0.00 ---- West Facing - TOTAL 124.48 114.38 10.10 8.1% Registration Number: 216-No111859A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:56:03 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 14:46, Wed, Mar 23, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U0PTxml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins CF1 R-PRF-NCB-01 Page 3 of 11 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 3 2899 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 living Conditioned HVAC System1 2899 10.1 DHW Sys 1 0 S Registration Number: 216-No111859A-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-03-23 14:56:03 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Description: Title 24 Analysis Calculation Date/Time: 14:46, Wed, Mar 23, 2016 Input File Name: 14023P3UOPTxml CF1 R-PRF-NCB-01 Page 4 of 11 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft2) Tilt(deg) Front Wall living R-19 Wall 0 Front 364 54 90 Left Wall living R-19 Wall 90 Left 485 30 90 Rear Wall living R-19 Wall 180 Back 566 20 90 Right Wall living R-19 Wall 270 Right 737 69 90 garage wall living R-19 Wall 0 Front 100 0 90 Front Wa112 living R-19 Wall 0 Front 192 12.5 90 Left Wa112 living R-19 Wall 90 Left 737 194 90 Rear Wa112 living R-19 Wall 180 Back 404 319.995 90 Right Wa112 living R-19 Wall 270 Right 737 180 90 garage wall2 living R-19 Walll 0 Front 100 0 90 Roof living R-38 Roof Attic RB 393 Roof2 living R-38 Roof Attic RB 2224 Exterior WallR Garage Garage Ext Wallr--- %, — - 270 Right 270 0 90 Exterior WallF Garage a' Garage Ext Walli Front,' 323 0 90 Exterior WallL Garage ` Garage Ext Wall"' t1 =90 ,�% - Left ' ` 293 0 90 Exterior Wall Garage ,y — _ r�pajrage Ext Wall ! '180 1 !BackK 10 0 90 Roofg Garage R-0 Roof Attic 519 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 5 0.1 0.85 Yes No Registration Number: 216-No111859A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:56:03 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 14:46, Wed, Mar 23, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPTxml CF1 R-PRF-NCB-01 Page 5 of 11 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height (ft) Width(ft ) Multiplie r Area (ft2) U- factor SHG C Exterior Shading 3050-2 Window Front Wall (Front-0) 8.0 6.0 0.625 30.0 0.34 0.22 3080 Window Front Wall (Front-0) 8.0 8.0 0.375 24.0 0.34 0.22 3080-1 frdr Window Left Wall (Left-90) 8.0 6.0 0.5 24.0 0.35 0.25 2030 Window Left Wall (Left-90) ---- ---- 1 6.0 0.34 0.22 2050 Window Rear Wall (Back-180) ---- ---- 1 20.0 0.39 0.29 2060-2 Window Right Wall (Right-270) ---- ---- 1 24.0 0.34 0.22 3050-3 Window Right Wall (Right-270) ---- ---- 1 45.0 0.34 0.22 2626 Window Front Wa112 (Front-0) ---- ---- 1 12.5 0.37 0.29 30802 Window Left Wall2 (Left-90) 5.0 5.0 0.96 24.0 0.35 0.25 4060-2 Window Left Wa112 (Left-90) ---- ---- 1 48.0 0.34 0.22 4020-2 Window Left Wa112 (Left-90) ---- ---- 1 16.0 0.34 0.22 3040--- Window .Left Wall2 (Left-90) , _ ,� r _,,_, r 5.0 f 5.0 0.48 12.0 0.34 0.22 2040-2 Window Left W6112 (Left-90) -_ J j i 5.0 I 15.O \ 0.64 16.0 0.34 0.22 3060 Window _16ft Wa112 (Left-90) _-, I Vki i^ i-- ? 1, 18.0 0.39 0.29 5060 Window ` Left_Wa112_(Left-90) i1 ,.� l ` _ , ti -- 1 30.0 0.34 0.22 30803 Window 'Left W6112 (Left=90) --= " ` -- "' - " 1 24.0 0.35 0.25 20302 Window Left W6112 (Left-90) ---- ---- 1 6.0 0.34 0.22 3060-2 Window Rear W6112 (Back-180) ---- ---- 1 36.0 0.34 0.22 3020-2 Window Rear Wa112 (Back-180) 3.0 3.0 1.333 12.0 0.34 0.22 6020 Window Rear W6112 (Back-180) ---- ---- 1 12.0 0.34 0.22 16080 Window Rear Wa112 (Back-180) 3.0 3.0 14.222 128.0 0.34 0.22 3080-3 frdr Window Rear W6112 (Back-180) 8.0 8.0 1.125 72.0 0.35 0.25 3020-4 Window Rear Wa112 (Back-180) ---- ---- 1 24.0 0.39 0.29 6060 Window Rear W6112 (Back-180) ---- ---- 1 36.0 0.39 0.29 2060-2 2 Window Right Wa112 (Right-270) ---- ---- 1 24.0 0.34 0.22 2020-2 Window Right Wa112 (Right-270) ---- ---- 1 8.0 0.34 0.22 20303 Window Right Wa112 (Right-270) ---- ---- 1 6.0 0.34 0.22 4050 Window Right Wa112 (Right-270) ---- ---- 1 20.0 0.34 0.22 2050-2 Window Right Wa112 (Right-270) ---- ---- 1 20.0 0.34 0.22 Registration Number: 216-N0111859A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:56:03 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 14:46, Wed, Mar 23, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPT.xml CF1 R-PRF-NCB-01 Page 6 of 11 9080ddr Window Right Wa112 (Right-270) I ---- I --- 1 1 72.0 0.34 0.22 50602 Window Right Wa112 (Right-270) 8.0 1 6.0 1 0.625 1 30.0 0.35 0.25 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up 3050-2 10 1 6 6 0 0 0 0 0 0 0 0 0 3080 10 1 6 6 0 0 0 0 0 0 0 0 0 3080-1 frdr 6 1 4 4 0 0 0 0 0 0 0 0 0 30802 0 0 0 0 0 0 0 0 0 0 0 0 0 3040--- 0 0 0 0 0 0 0 0 0 0 0 0 0 2040-2 0 0 0 0 0 0 0 0 0 0 0 0 0 3020-2 2 2 2 2 0 0 0 0 0 0 0 0 0 16080 12 1 10 10 0 0 0 0 0 0 0 0 0 3080-3frdr 2 2 2 /2 _ 0 �; 0{�_ 0; -� 0� 0 0 0 0 0 50602 10 1 61e. '\6, 0 0 1 0 0` 0 0 0 0 0 Registration Number: 216-N0111859A-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-03-23 14:56:03 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 14:46, Wed, Mar 23, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPT.xml CF1 R-PRF-NCB-01 Page 7 of 11 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (Roofule) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic floor - Cavity: - no insulation - Sheathinglnsulation - no sheathingfinsul. - R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: R 19 Sheathing/Insulation: - no sheathinglinsul. - R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Attic Floor: - no attic floor - Cavity: R 38 _ Sheathinglnsulation - no sheathinglnsul. - R-38 Roof Attic RB Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 iri. O.C; R 38 _ Inside Finish: Gypsum Board Inside Finish: Gypsum Board -- �j •'��-Sheathing/insulation: - no sheathing/nsul. - �, Cavity: R 19 Sheathing/lnsulation: - no sheathinglnsul. - R-19 Walll Exterior Walls Wood °Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Inside Finish: Gypsum Board Sheathing/lnsulation: - no sheathingAnsul. - Cavity: - no insulation (vertical) - - no insulation Sheathing/Insulation: - no sheathinglinsul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. (vertical) - Exterior Finish: 3 Coat Stucco SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab living 304 40 None 0.8 No Slab2 living 2224 255 None 0.8 No Slab -on -Grade Garage 519 122 None 0 No Registration Number: 216-No111659A-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:56:03 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 14:46, Wed, Mar 23, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPT.xml CF1 R-PRF-NCB-01 Page 8 of 11 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED REQUIRED 1464.0 WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Standard 1 0.0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0 0.95 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION / `� I= t'`- ' =� �- i f- = - 01 02 r < < 03 ,= 3 ' `' = t �. f '-04 i t " r r 05 06 07 Name Pipe Insulation Parallel Pipings C Ir,7 J #Compact Distribution, l` U —Point-of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a - n/a - — n/a — n/a n/a HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC System1 Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 2899 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 216-No111859A-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:56:03 il CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Description: Title 24 Analysis Calculation Date/Time: 14:46, Wed, Mar 23, 2016 Input File Name: 14023P3UOPTxml CF1 R-PRF-NCB-01 Page 9of11 HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 12.5 15 Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Not Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in unconditioned - -- Sealed and tested / r � 6 )J — "� r Attic Attic None Air Distribution System 1-hers-dist attic r , y HVAC DISTRIBUTION - HERS VERIFICATION 01 02 -.11 03— W P V = r04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 Registration Number: 216-N0111859A-000000000-0000 Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:56:03 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-NCB-01 Project Name: Plan 3 Calculation Date/Time: 14:46, Wed, Mar 23, 2016 Page 10 of 11 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPTxml IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 59 Exhaust 0 Required COOLING VENTILATION NONE Registration Number: 216-No111859A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance F R S R 0 V Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: CaICERTS inc. Report Version - CF1R-05072014-595c Report Generated at: 2016-03-23 14:56:03 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 14:46, Wed, Mar 23, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPTxml CF1 R-PRF-NCB-01 Page 11 of 11 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Rudy Sains Company: Signature Date: Heritage Energy Group 2016-03-23 16:09:12 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949-584-1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: . ResponsibleDesigner Signature: f%adPi Dave Warren ✓ �` �, -_ . 1, , `� _ lfi�teifi Company: - Date Signed: California West Communities k `" ' 16-03-23 6:10:53�' Address: License: 5927 Priestly Drive, Suite 103 N/A City/State/Zip: Phone: Carlsbad, CA 92008 760-918-2824 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-N0111859A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2016-03-23 16:10:53 HERS Provider: Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-03-23 14:56:03 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name The Estates -Plan 3 Date 3/23/2016 System Name HVAC System Floor Area 2,899 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 2,097 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 41,755 3,084 1,062 40,691 Total Output (Btuh) 89,000 0 Output Btuh/s ft 30.7 2,311 1,806 Cooling S stem o 0 Output per System 46,500 0 0 0 0 Total Output Btuh 46,500 0 3,084 0 Total Output (Tons) 3•9 2,311 1,806 Total Output (Btuh/s ft) 16.0 Total Output (s ft/Ton) 748.1 1 46,376 44,303 Air System CFM per System 1,680 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,680 15/12/80% 32,057 7,596 89,000 Airflow (cfm/s ft) 0.58 Airflow (cfm/Ton) 433.5 Outside Air (%) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 32,057 7,596 89,000 Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 67 OF Outside Air 0 cfm Supply Fan 1,680 cfm 67 OF 67 OF 105 OF Heating Coil 104 OF i� ROOM 68 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 112/78OF 76/62OF Outside Air Ar 0 cfm 76/62OF 76/62OF 55/54OF Supply Fan Cooling Coil 56 / 54 OF 1,680 cfm p 48.1 % R , OOM in 75/62OF EnergyPro 6.2 by EnergySoft User Number: 7244 Run Code: 2016-03-23T16:25:11 ID: 14023 Page 1 of 1 _01 c � Title 24 Energy Report The Estates at PGA West La Quinta 2013 Building Energy Efficiency Standards Revised Report: Plan Check Comments, Delta 4 Plans, and Plan 1 & 2 Options BEG Project No.: 14023U California West Construction Bassenian Lagoni Heritage Energy Group, LLC May 18, 2016 Tel: (949) 789-7221 / Fax: (949) 789-7222 JUN 2 3 2016 CITY OF LA QUINTA COMMUNITY DEVELOPMENT f f CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Projec`, , me: Plan 1 - The Estates Calculation Date/Time: 21:57, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1 U.xml f1 CF1 R-PRF-NCB-01 Page 1 of 11 GENERAL INFORMATION 01 Project Name Plan 1 - The Estates 02 Calculation Description Title 24 Analysis 03 Project Location The Estates 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-2 (595c) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 2528 15 Number of Zones 2 16 Slab Area (FT2) 2528 17 Number of Stories 1 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area {FT?) NA 21 Glazing Percentage (%) 35.7% Detailed help on using the CFA R Certificate ofiCompliance s available via the Internet by either scannin the OR code or;br'owsin to: j r L 0 http://www.title24enrgycod�e.og/t2elS f1r.arpx V I E R ■ a COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-N0111859B-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:07:49 r r CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project 1 ame: Plan 1 - The Estates Calculation Date/Time: 21:57, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1 U.xml I' S CFI R-PRF-NCB-01 Page 2of11 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 2.26 1.98 0.28 12.4% Space Cooling 114.10 118.46 -4.36 -3.8% IAQ Ventilation 0.98 0.98 0.00 0.0% Water Heating 11.18 5.76 5.42 48.5% PV Credit ---- 0.00 0.00 --- North Facing - TOTAL 128.52 127.18 1.34 1.0% Space Heating 2.26 2.86 -0.60 -26.5% Space Cooling 114.10 117.88 -3.78 -3.3% IAQ Ventilation 0.98 0.98 0.00 0.0% Water Heating 11.18 5.76 5.42 48.5% PV Credit ---- 0.00 0.00 --- East Facing - TOTAL 128.52 127.48 1.04 0.8% Space Heating -2.26 3.16 -0.90 -39.8% Space Cooling IAQ Ventilation \ / -0.9898'0.00 11.4710 R�l4:71 -0.61 -0.5% 0.0% Water Heating �' 11.18. .76; nc 542 48.5% PV Credit a E \l R S P R0.0 �) � / � D E R 0:00 South Facing - TOTAL 128.52 T t i` 124.61/ 3.91 ° 3.0 /° Space Heating 2.26 2.08 0.18 8.0% Space Cooling 114.10 114.03 0.07 0.1 % IAQ Ventilation 0.98 0.98 0.00 0.0% Water Heating 11.18 5.76 5.42 48.5% PV Credit ---- 0.00 0.00 ---- West Facing -TOTAL 128.52 122.85 5.67 4.4% Registration Number: 216-N0111859B-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:07:49 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-NCB-01 Project Name: Plan 1 - The Estates Calculation Daterrime: 21:57, Tue, May 17, 2016 Page 3 of 11 Calculation Description: Title 24 Analysis Input File Name: 14023P1 U.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. Window overhangs and/or fins BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 1- The Estates 2528 1 3 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone ,Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 living Conditioned HVAC SystemM1 2224 10.1 DHW Sys 1 Casita Conditioned HVAC SystemC2 304 10.1 DHW Sys 1 (: --, C CEPTS n co Registration Number: 216-N0111859B-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-17 22:07:49 r r CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 21:57, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1 U.xml I t CF1 R-PRF-NCB-01 Page 4 of 11 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window Area (ft) Tilt(deg) Front Wall living R-19 Wall 0 Front 348 84.5 90 Left Wall living R-19 Wall 90 Left 717 138 90 Rear Wall living R-19 Wall 180 Back 566 338 90 Right Wall living R-19 Wall 270 Right 737 198 90 Roof living R-38 Roof Attic RB 2224 Interior Surface living»Garage R-19 Wall1 200 Front Wall 2 Casita R-19 Wall 0 Front 136 0 90 Left Wall 2 Casita R-19 Wall 90 Left 225 48 90 Rear Wall 2 Casita R-19 Wall 180 Back 136 72 90 Right Wall 2 Casita R-19 Wall 270 Right 225 24 90 Roof 2 Casita R-38 Roof Attic RB 304 Interior Surface 3 \ Casita»Garage R-19 Wall 100 garage wall right Garage �� ! Garage Ext Wall �� 270 _ Right 341 0 90 garage wall front Garage r —J garage Ext Wall . -`180 Backs 363 0 90 garage wall left Garagei �-' � Garage Ezt Wall' -90 ft 341 0 90 Exterior Wall Garage., H � <Ga�age Ext Wall 0 ]l Front 1 0 90 Roof 3 Garage Garage Roof 521 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 5 0.1 0.85 Yes No Registration Number: 216-N0111859B-000000000-0000 Registration Date/Time: 2016-05-1808:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:07:49 I f CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 -The Estates Calculation Date/Time: 21:57, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1U.xml .1 1 CF1 R-PRF-NCB-01 Page 5 of 11 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height (ft) Width(ft ) Multiplie r Area (W) U- factor SHG C Exterior Shading (2)2626 Window Front Wall (Front-0) ---- ---- 1 12.5 0.27 0.23 9080 Window Front Wall (Front-0) 8.0 9.0 1 72.0 0.28 0.21 3080 Window Left Wall (Left-90) 8.0 3.0 1 24.0 0.34 0.16 3020 Window Left Wall (Left-90) 2.0 3.0 1 6.0 0.27 0.23 (2)4060 Window Left Wall (Left-90) ---- ---- 1 48.0 0.29 0.20 (2)3040 Window Left Wall (Left-90) 4.0 6.0 1 24.0 0.29 0.20 3040 Window Left Wall (Left-90) 4.0 3.0 1 12.0 0.29 0.20 (2)4020 Window Left Wall (Left-90) 2.0 8.0 1 16.0 0.27 0.23 2040 Window Left Wall (Left-90) ---- ---- 1 8.0 0.29 0.20 12080 Window Rear Wall (Back-180) 8.0 12.0 1 96.0 0.28 0.21 90802 Window Rear Wall (Back-180) 8.0 9.0 1 72.0 0.28 0.21 16080 Window Rear Wall (Back.1.80) -._y f__._ 8.0 16.0 1 128.0 0.28 0.21 Fixed Transoms Window / �� Rear Wall (Back-180) 2.0 { 'b 2Y0,'� 1 42.0 0.27 0.23 (2)3080 Window \l,_Righi Wall k(Right-27�0) �� ) it - ��-,1n 48.0 0.34 0.16 (2)2020 Window ,'' `� t Right Walljl fight-270) r.� r), t--% - ol 1 8.0 0.27 0.23 (2)2060 Window ."` �` Right 1Nall`(Right`270) ---- ---` 1 24.0 0.29 0.20 2030 Window Right Wall (Right-270) ---- ---- 1 6.0 0.29 0.20 4050 Window Right Wall (Right-270) ---- ---- 1 20.0 0.29 0.20 (2)2050 Window Right Wall (Right-270) ---- ---- 1 20.0 0.29 0.20 90803 Window Right Wall (Right-270) ---- ---- 1 72.0 0.28 0.21 3080-2 frdr Window Left Wall 2 (Left-90) 8.0 6.0 1 48.0 0.34 0.16 9080 ddr Window Rear Wall 2 (Back-180) ---- ---- 1 72.0 0.28 0.21 2060 Window Right Wall 2 (Right-270) - - --- 1 12.0 0.29 0.20 20602 Window Right Wall 2 (Right-270) ---- ---- 1 12.0 0.29 1 0.20 Registration Number: 216-N0111859B-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:07:49 r CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 21:57, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1 U.xml r CF1 R-PRF-NCB-01 Page 6 of 11 DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door Right Wall 28.0 0.50 Door 16080 garage wall front 128.0 1.00 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 9080 2 1 2 2 0 0 0 0 0 0 0 0 0 3080 12 0.5 10 10 1 0 0 0 0 0 0 0 0 3020 12 0.5 10 10 1 0 0 0 0 0 0 0 0 (2)3040 2 2 2 2 0 0 0 0 0 0 0 0 0 3040 2 .2 -2 2, _ y 0, -____-_0 � 0, 0 0 0 0 0 0 (2)4020 12080 2 , 2,_ C 1 �� 2 2 2Y r� �2 i 2,.._.,. -� 0 L)) M---.� �� 110k1,, 11 0 oil r. 17 Oil � � O f� � � 0 � 0 ^� 0 0 0 0 0 0 0 0 0 9080 2 2 "2 t t2 r. r 2 c. r t t �,. 0 t 0�„y tn.. 0 0 0 0 0 0 16080 12 6`5 " 10 ` " 1410"'. ` 1 '"`0 ` 0—.. "`" 0' L. 0 0 0 0 0 Fixed Transoms 2 1 2 2 0 0 0 0 0 0 0 0 0 3080-2 frdr 12 0.5 10 10 1 0 0 0 0 0 0 0 0 Registration Number: 216-N0111859B-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:07:49 I t CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 21:57, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1U.xml ! r CF1 R-PRF-NCB-01 Page 7of11 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic floor - Cavity: - no insulation - Sheathinglnsulation - no sheathing/insul. - Garage Roof Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Attic Floor: - no attic floor - _ Cavity. R 38 Sheathinglnsulation - no sheathing/insul. - R-38 Roof Attic RB Ceilings (below attic) Wood rF amed Ceiling' ,2x4'@ 24 n`: O.0 R 38 Inside Finish: Gypsum Board Uk�, ' = �' u U Inside Finish: Gypsum Board .•Sheathing/Insulation: - no sheathing/insul. - H C i• R Cavity: R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Walll Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Other Side Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: - no insulation (vertical) - - no insulation Sheathing/Insulation: - no sheathing/insul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. (vertical) - Exterior Finish: 3 Coat Stucco SLABFLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab living 2224 255 None 0.8 No Slab 2 Casita 304 72 None 0.8 No Slab 3 Garage 521 128 None 0 No Registration Number: 216-N0111859B-000000000-0000 Registration Date/Time: 2016-05-1808:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:07:49 f CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 21:57, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1 U.xml t r CFI R-PRF-NCB-01 Page 8 of 11 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED NOT REQUIRED --- WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Standard 1 0.0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0 0.95 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION, � � � c7c n _ 01 1r tt -•,.02n t t 7 03 f i `: t �'04's 1 1 I i 05 06 07 U U '. L it L '.r r/ U 1 U 0 Recirculation with Recirculation with Name ' Pipe Insulation LJ K= Parallel --Piping L *Compact,Distribution, eointt-,of Use Manual Control Sensor Control DHW Sys 1-hers-dhw n/a n/a - "-` ri7a - -� y n/a n/a HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC SystemM1 Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 2224 HVAC SystemC2 Other Heating and Cooling System Heating Component 2 Yes HVAC SystemC2-cool Yes Air Distribution System 2 HVAC Fan 2 304 Registration Number: 216-No111859B-000000000-0000 Registration Date/Time:2016-05-1808:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:07:49 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 21:57, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1 U.xml r t CFI R-PRF-NCB-01 Page 9of11 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 95 AFUE Heating Component 2 CntrlFurnace - Fuel -fired central furnace 93 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 12 14 Cooling Component 1-hers-cool HVAC SystemC2-cool SplitAirCond - Split air conditioning system 11.3 13 HVAC SystemC2-cool-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name ' ` Verified Airflowl� _ �� �r Airflow Target) 9 f Verified EERY y r Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool / ,-_Required �� i� ' ,350 `)Not Requir`dd Required Required HVAC SystemC2-cool-hers-cool :,'' NR�equired �' "- '"' `� 350` � bRequiret!4 u V Not Required Required `I F 6-4 P. - id 1%, i- F 6--c a I \ / f a I a— K HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in unconditioned Specified Lower 6 Attic Attic None Air Distribution attic Leakage Target System 1-hers-dist Air Distribution System 2 Ducts located entirely in Specified Lower 6 Conditioned Zone Conditioned Zone None Air Distribution conditioned space Leakage Target System 2-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required Air Distribution System 2-hers-dist Required 6.0 Required Not Required Not Required Registration Number: 216-N0111859B-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595c Report Generated at: 2016-05-17 22:07:49 t CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 21:57, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1 U.xml t I CF1 R-PRF-NCB-01 Page 10 of 11 HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 HVAC Fan 2-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 55� rt -,Exhaust, 0 Required COOLING VENTILATION NJ NONE Registration Number: 216-N0111859B-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-17 22:07:49 t I CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 21:57, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1 U.xml t t CF1 R-PRF-NCB-01 Page 11 of 11 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Rudy Sains Company: Signature Date: Heritage Energy Group 2016-05-18 08:38:36 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949-584-1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. �k 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans ant! specifications submitted to the enforcement agency,for approval with,this,.building permit application. Responsible Designer Name: (( L O "I Re'sponisibleDesigner Sigrjiajtujre: Dave Warren .11 Company: p HERS Date Signed: ER 2016-05 1 8: 9:52'� California West Communities Address: License: 5927 Priestly Drive, Suite 103 N/A City/State/Zip: Phone: Carlsbad, CA 92008 760-918-2824 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-N0111859B-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:07:49 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 22:09, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1Uopt.xml i 1 CF1 R-PRF-NC9-01 Page 1 of 11 GENERAL INFORMATION 01 Project Name Plan 1 - The Estates 02 Calculation Description Title 24 Analysis 03 Project Location The Estates 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-2 (595c) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 2788 15 Number of Zones 2 16 Slab Area (FT2) 2788 17 Number of Stories 1 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT?) NA 21 T Glazing Percentage (%) 27.2% Detailed help on using the CFAR Certificate ofCopliana is a ailb viathee Intr t by either 91ktR1 scannin�ge QRcode orwst�g��to11 CU http://www.tit;e energycode.org/t24hf-kelp/cfl r.aspx,�^� �/ t COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-NO11187OB-000000000-0000 Registration Date/Time: 2016-05-1808:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:19:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 22:09, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1 Uopt.xml CFI R-PRF-NCB-01 Page 2of11 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.94 1.62 0.32 16.5% Space Cooling 109.38 107.11 2.27 2.1 % IAQ Ventilation 0.93 0.93 0.00 0.0% Water Heating 10.13 5.23 4.90 48.4% PV Credit ---- 0.00 0.00 --- North Facing -TOTAL 122.38 114.89 7.49 6.1% Space Heating 1.94 2.31 -0.37 -19.1% Space Cooling 109.38 102.90 6.48 5.9% IAQ Ventilation 0.93 0.93 0.00 0.0% Water Heating 10.13 5.23 4.90 48.4% PV Credit ---- 0.00 0.00 --- East Facing - TOTAL 122.38 111.37 11.01 9.0% Space Heating 1:94 - 2.81 -0.87 -44.8% Space Cooling IAQ Ventilation '0.93 109?38 ED440M 0.931 L5.23 4.98 0.00 4.6% 0.0% Water Heating 10,13 4:90 48.4% PV Credit F4 E p S P R0. Z-) V I D E 0.00 ---- South Facing -TOTAL 122.38 f 1 113.37 9.01 7.4% Space Heating 1.94 1.74 0.20 10.3% Space Cooling 109.38 99.58 9.80 9.0% IAQ Ventilation 0.93 0.93 0.00 0.0% Water Heating 10.13 5.23 4.90 48.4% PV Credit ---- 0.00 0.00 ---- West Facing -TOTAL 122.38 107.48 14.90 12.2% Registration Number: 216-NO11187OB-000000000-0000 Registration Date/Time: 2016-05-1808:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:19:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-NC9-01 Project Name: Plan 1 - The Estates Calculation Date/Time: 22:09, Tue, May 17, 2016 Page 3 of 11 Calculation Description: Title 24 Analysis Input File Name: 14023P1 Uopt.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. Window overhangs and/or fins BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 1- The Estates 2788 1 3 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 living Conditioned, HVAC SystemMl 2516 10.1 DHW Sys 1 Casita Conditioned HVAC SystemC2 272 10.1 DHW Sys 1 n c o C E Rc Ccr HERS PRC7VI DER Registration Number: 216-NO11187OB-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-17 22:19:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 22:09, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1 Uopt.xml CF1 R-PRF-NCB-01 Page 4 of 11 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft) Tilt(deg) Front Wall living R-19 Wall 0 Front 348 12.5 90 Left Wall living R-19 Wall 90 Left 717 156 90 Rear Wall living R-19 Wall 180 Back 566 338 90 Right Wall living R-19 Wall 270 Right 737 180 90 Roof living R-38 Roof Attic RB 2516 Interior Surface living»Garage R-19 Wall1 200 Front Wall 2 Casita R-19 Wall 0 Front 136 0 90 Left Wall 2 Casita R-19 Wall 90 Left 225 48 90 Rear Wall 2 Casita R-19 Wall 180 Back 136 0 90 Right Wall 2 Casita R-19 Wall 270 Right 225 24 90 Roof 2 Casita R-38 Roof Attic RB 272 Interior Surface 3 Casita—Garage R-19 Wall 100 garage wall right Garage . - G;a'rage Ext; ' Wall I�rr270 f Right, 341 0 90 garage wall front Garage Iw f garage Ext Wall=:� "180 j j f Backs 363 0 90 garage wall left Garaged �' ; ^� Garage E;4Walf! u r 'Z--90 U 1 u L6 '�4 341 0 90 Exterior Wall Garage., Garage Ext 1Nall K ( N,0 Front 1 0 90 Roof 3 Garage Garage Roof 521 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 5 0.1 0.85 Yes No Registration Number: 216-NO11187OB-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:19:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 22:09, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1 Uopt.xml CF1 R-PRF-NCB-01 Page 5of11 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height (ft) Width(ft ) Multiplie r Area (ft2) U- factor SHG C Exterior Shading (2)2626 Window Front Wall (Front-0) ---- ---- 1 12.5 0.27 0.23 3080 Window Left Wall (Left-90) 8.0 3.0 1 24.0 0.34 0.16 3020 Window Left Wall (Left-90) 2.0 3.0 1 6.0 1 0.27 0.23 (2)4060 Window Left Wall (Left-90) ---- ---- 1 48.0 0.29 0.20 (2)3040 Window Left Wall (Left-90) 4.0 6.0 1 24.0 0.29 0.20 2040 Window Left Wall (Left-90) 4.0 2.0 1 8.0 0.29 0.20 (2)4020 Window Left Wall (Left-90) 2.0 8.0 1 16.0 0.27 0.23 5060 Window Left Wall (Left-90) ---- ---- 1 30.0 0.29 0.20 12080 Window Rear Wall (Back-180) 8.0 12.0 1 96.0 0.28 0.21 9080 Window Rear Wall (Back-180) 8.0 9.0 1 72.0 0.28 0.21 16080 Window Rear Wall (Back-180) 8.0 16.0 1 128.0 0.28 0.21 Fixed Transoms Window' ' . - r,^.Rear Wall, {Back-1.80).,_._ r._.� .� 2.0 21.0 1 42.0 0.27 0.23 6050 Window r, Ci Right Wall (Right-270) L_. ff -- `� 1 30.0 0.29 0.20 (2)2020 Window �_Ridht Wall}(Right-270) � ,41{.� 8.0 0.27 0.23 (2)2060 Window L Right Wall,(Rightti270) >--� �.`'* - tom! 1 24.0 0.29 0.20 2030 Window ` Right Wall'(Right=270) `"� ` --`- ` y ` ' 1 6.0 0.29 0.20 4050 Window Right Wall (Right-270) ---- ---- 1 20.0 0.29 0.20 (2)2050 Window Right Wall (Right-270) ---- ---- 1 20.0 0.29 0.20 90802 Window Right Wall (Right-270) ---- ---- 1 72.0 0.28 0.21 3080-2 frdr Window Left Wall 2 (Left-90) 8.0 6.0 1 48.0 0.34 0.16 2060 Window Right Wall 2 (Right-270) ---- ---- 1 12.0 0.29 0.20 20602 Window Right Wall 2 (Right-270) ---- ---- 1 12.0 0.29 0.20 DOORS 01 02 03 04 Name Side of Building Area (ft) U-factor Door Right Wall 28.0 0.50 Door 16080 garage wall front 128.0 1.00 Registration Number: 216-NO11187OB-000000000-0000 Registration Date/Time: 2016-05-1808:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:19:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 22:09, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1 Uopt.xml CFI R-P'RF-NCB=01 Page 6 of 11 OVERHANGS AND FINS 01 02 03 04 1 05 06 07 08 09 10 11 1 12 1 13 1 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up 3080 12 0.5 10 10 1 0 0 0 0 0 0 0 0 3020 12 0.5 10 10 1 0 0 0 0 0 0 0 0 (2)3040 2 2 2 2 0 0 0 0 0 0 0 0 0 2040 2 2 2 2 0 0 0 0 0 0 0 0 0 (2)4020 2 1 2 2 0 0 0 0 0 0 0 0 0 12080 2 2 2 2 0 0 0 0 0 0 0 0 0 9080 2 2 2 2 0 0 0 0 0 0 0 0 0 16080 12 0.5 10 10 1 0 0 0 0 0 0 0 0 Fixed Transoms 2' ', 1 2 2 0 0 0 0 0 0 0 0 0 3080-2 frdr 12 0.5 10 10 1 0 0 0 0 0 0 0 0 C E RTS n co HERS PROVI DER Registration Number: 216-NO11187OB-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-17 22:19:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 22:09, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1 Uopt.xml CF1 R-PRF-NCB-01 Page 7 of 11 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity. - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic floor - Cavity: - no insulation - Sheathinglnsulation - no sheathing/insul. - Garage Roof Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Wall Exterior. Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Attic Floor: - no attic floor - Cavity. R 38 Sheathinglnsulation - no sheathing/insul. - R-38 Roof Attic RB Ceilings (below attic) Wood'Framed Ceiling— ' 2x4 @ 24 in: O77:: R 381 Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - H E R S P R It.../ Y I E• R Cavity: R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Other Side Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity. - no insulation (vertical) - - no insulation Sheathing/Insulation: - no sheathing/insul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. (vertical) - Exterior Finish: 3 Coat Stucco SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab living 2516 255 None 0.8 No Slab 2 Casita 272 72 None 0.8 No Slab 3 Garage 521 128 None 0 No Registration Number: 216-NO11187OB-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:19:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 22:09, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1Uopt.xml CF1 R-PRF-NC6-01 Page 8 of 11 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED NOT REQUIRED --- WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Standard 1 0.0% WATER HEATERS 01 02• 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0 0.95 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION - 01 tt'�-`7���j 02 k r� [ �. 03 f ' r~; i '` U4,� i i r t'� 05 06 07 Name Pipe Insulation LJ 11 IC PEarallel-Pipingb C t U 7 U yCompact'D stribution, 3 U `. % rpoint,of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a - ' n/a ri/a n/a n/a HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC SystemM1 Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 2516 HVAC SystemC2 Other Heating and Cooling System Heating Component 2 Yes HVAC SystemC2-cool Yes Air Distribution System 2 HVAC Fan 2 272 Registration Number: 216-NO11187OB-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:19:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 22:09, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1 Uopt.xml CF1 R-PRF-NCB-01 Page 9 of 11 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 95 AFUE Heating Component 2 CntrlFurnace - Fuel -fired central furnace 93 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 12 14 Cooling Component 1-hers-cool HVAC SystemC2-cool SplitAirCond - Split air conditioning system 11.3 13 HVAC SystemC2-cool-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow'Airflow J Targetl Verified EERY ti Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool r Req fired 1, ` � 350 i t� -� Not Required C Required Required HVAC SystemC2-cool-hers-cool NRequired �"� i u '�-3 L350' u u u `=-' bRequi�edJ U "- u Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in unconditioned Specified Lower 6 Attic Attic None Air Distribution attic Leakage Target System 1-hers-dist Air Distribution System 2 Ducts located entirely in Specified Lower 6 Conditioned Zone Conditioned Zone None Air Distribution conditioned space Leakage Target System 2-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required TNot Required Air Distribution System 2-hers-dist Required 6.0 Required Not Required Not Required Registration Number: 216-NO11187OB-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-17 22:19:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 22:09, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1 Uopt.xml CF1 R-PRF-NCB-01 Page 10 of 11 HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 HVAC Fan 2-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name -IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 58_, Exhaust � 0 Required COOLING VENTILATION -'"NONE w Registration Number: 216-NO11187OB-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-17 22:19:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - The Estates Calculation Date/Time: 22:09, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P1Uopt.xml 6 CFI R-PRF-NCB-01 Page 11 of 11 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Rudy Sains Company: Signature Date: Heritage Energy Group 2016-05-18 08:38:36 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949-584-1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to -,the enforcement.agency,for approval with,this,building permit application. Responsible Designer Name: f L -R^e�sponsibleDesigner Sigrjiature:� �a�Pi�a�vzesv Dave Warren C4._11 1 �—�� J t� n i t 1 r� Company: Date Signed: 2016-05 18 08: 9:52� California West Communities Address: License: 5927 Priestly Drive, Suite 103 N/A City/State/Zip: Phone: Carlsbad, CA 92008 760-918-2824 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-NO11187OB-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:19:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Date/Time: 22:45, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2U.xml CF1 R-PRF-NCB-01 Page 1 of 10 GENERAL INFORMATION 01 Project Name Plan 2 02 Calculation Description Title 24 Analysis 03 Project Location The Estates 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-2 (595c) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT') 2760 15 Number of Zones 1 16 Slab Area (FT2) 2760 17 Number of Stories 1 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT?) NA 21 Glazing Percentage (%) 29.6% r t7=,- r= r5:-� n Detailed help on using the CF-1R Certificate ofrCompliance is available via'the'Internet by either scanningthe QR code or -browsing toLC=: j Co Q Q ' �± http://www.title24energycode.org/t24help/cfl r.aspx v ll" it kl... >► J t" R 0 V I D E R Q COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-NO184611A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:53:41 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Date/Time: 22:45, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2U.xml CF1 R-PkF-NCB-101 Page 2 of 10 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.37 1.25 0.12 8.8% Space Cooling 102.71 107.62 -4.91 -4.8% IAQ Ventilation 1.05 1.05 0.00 0.0% Water Heating 10.24 5.28 4.96 48.4% PV Credit ---- 0.00 0.00 ---- North Facing -TOTAL 115.37 115.20 0.17 0.1% Space Heating 1.37 2.12 -0.75 -54.7% Space Cooling 102.71 103.26 -0.55 -0.5% IAQ Ventilation 1.05 1.05 0.00 0.0% Water Heating 10.24 5.28 4.96 48.4% PV Credit ---- 0.00 0.00 --- East Facing - TOTAL 115.37 111.71 3.66 3.2% Space Heating 1.37 1.80 -0.43 -31.4% Space Cooling \ •, 102;7.1 3.73� -1.02 -1.0% IAQ Ventilation Water Heating10.24. -` .05 a .05.0.00 C E .28 R�, 4;96 0.0% 48.4 /o PV Credit E R S P RO.OZ,) +� lI E R 0.00 #� -- South Facing - TOTAL 115.37 111.86 V 3.51 3.0% Space Heating 1.37 0.87 0.50 36.5% Space Cooling 102.71 103.22 -0.51 -0.5% IAQ Ventilation 1.05 1.05 0.00 0.0% Water Heating 10.24 5.28 4.96 48.4% PV Credit ---- 0.00 0.00 ---- West Facing - TOTAL 115.37 110.42 4.95 4.3% Registration Number: 216-No184611A-000000000-0000 Registration Date/Time:2016-05-1808:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:53:41 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Description: Title 24 Analysis Calculation Date/Time: 22:45, Tue, May 17, 2016 Input File Name: 14023P2U.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins CF1 R-PRF-NC6-01 Page 3 of 10 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 2 2760 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 living Conditioned HVAC Systeml 2760 13.5 DHW Sys 1 OPAQUE SURFACES n 01 02.E j a �� 03 =:, ',:04 05 rf " F 06 07 08 Name �„ ,j Zone iiction1i �.+ Constru.. � 1emuth p Azitatns Orienio 1 `Gross Area (ftz) z Window Area (ft) Tilt(deg) Front Wall living � R `R'y19 Waller R { ',q" Front 243 83 90 Left Wall living R-19 Wall 90 Left 285 129 90 Rear Wall living R-19 Wall 180 Back 729 330 90 Right Wall living R-19 Wall 270 Right 1269 276 90 garage wall2 living R-19 Wall 0 Front 320 0 90 Roof living R-38 Roof Attic RB 2760 garage wall right Garage Garage Ext Wall 270 Right 143 0 90 garage wall front Garage Garage Ext Wall 180 Back 304 0 90 garage wall left Garage Garage Ext Wall 90 Left 285 0 90 Exterior Wall Garage Garage Ext Wall 0 Front 1 0 90 Roof 2 Garage Garage Roof 521 Registration Number: 216-N0184611A-000000000-0000 Registration Date/Time: 2016-05-1808:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:53:41 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Date/Time: 22:45, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2U.xml CFI R-PRF-NCB=01 Page 4 of 10 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 5 0.1 0.85 Yes No WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height (I t) Width(I t ) Multiplie r Area (ft2) U- factor SHG C Exterior Shading 9080 dr Window Front Wall (Front-0) 8.0 9.0 1 72.0 0.28 0.21 1626-3 Window Front Wall (Front-0) ---- ---- 1 11.0 0.27 0.23 3060-2 Window Left Wall (Left-90) 6.0 6.0 1 36.0 0.29 0.20 3020-2 Window Left Wall (Left-90) 2.0 6.0 1 12.0 0.27 0.23 4050 Window Left Wall (Left-90) ---- ---- 1 20.0 0.29 0.20 10020 Window Left Wall (Left-90) 2.0 10.0 1 20.0 0.27 0.23 2040-2 Window, ' Left Wally(Left-90) _- 4.0 4.0 1 16.0 0.29 0.20 5050 Window Left Wall (Left-90) 1, �( 5.0 ! t5.0N r.,--1 25.0 0.29 0.20 12080 dr Window ar Wall.(Back-180)• J -- k -- 1 96.0 0.28 0.21 16080 dr Window ' ,' Rearr.. - Wall (Back180 -) - 8.0 16.01 128.0 0.28 0.21 9080 dr 2 Window 1� Rear• Walll(Back-1.80) 9 1 N-0 V 8.0 t .Of 9.0- t A 1 72.0 0.28 0.21 2020-6 Window Rear Wall (Back-180) 2.0 17.0 1 34.0 0.27 0.23 4060-2 Window Right Wall (Right-270) ---- ---- 1 48.0 0.29 0.20 4030-2 Window Right Wall (Right-270) -- ---- 1 24.0 0.27 0.23 2020-2 Window Right Wall (Right-270) ---- ---- 1 8.0 0.27 0.23 2060-2 Window Right Wall (Right-270) ---- ---- 1 24.0 0.29 0.20 2030-2 Window Right Wall (Right-270) ---- ---- 1 12.0 0.27 0.23 2040-2 2 Window Right Wall (Right-270) ---- ---- 1 16.0 0.29 0.20 3050-2 Window Right Wall (Right-270) ---- ---- 1 30.0 0.29 0.20 3030-2 Window Right Wall (Right-270) ---- ---- 1 18.0 0.27 0.23 12080 Window Right Wall (Right-270) 8.0 12.0 1 96.0 0.28 0.21 Registration Number: 216-N0184611A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:53:41 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Date/Time: 22:45, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2U.xml CFI R-PRF-NCB-01 Page 5 of 10 DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door 16080 garage wall front 128.0 1.00 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 9080 dr 2 0.5 2 2 0 0 0 0 0 0 0 0 0 3060-2 0 0 0 0 0 0 0 0 0 0 0 0 0 3020-2 2 0.5 2 2 0 0 0 0 0 0 0 0 0 10020 2 0.5 2 2 0 0 0 0 0 0 0 0 0 2040-2 2 0.5 2 2 0 0 0 0 0 0 0 0 0 5050 2 0.5 2 2r,- g 4 0� ti _0 0 0 0 0 0 0 0 16080 dr 12 ` ,. 1 10� 1 1 110 " 0 U) 11 ok�, Oj 1 0� 0 0 0 0 0 9080dr2 .2 <" ,��0•5 � 11 \?ti..�, L-0 �� II 01J, rr Oil 11 11 1 0 0 0 0 0 2020 6 2 , 0:5 a `2 g-. r-s 2 qr- r. , rn e- 0 ,L A u# 0_,,% r7 0� 0 0 0 0 0 12080 2 6:5 '2 "" 41" 2' 0 to S` """`0 r Y 0� %- 0' ti 0 0 0 0 0 Registration Number: 216-N0184611A-000000000-0000 Registration Date/Time: 2016-05-1808:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:53:41 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Date/Time: 22:45, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2U.xml CFI R-PRF-NCB-01 Page 6 of 10 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic floor - Cavity. - no insulation - Sheathinglnsulation - no sheathing/insul. - Garage Roof Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity. R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Attic Floor: - no attic floor - - Cavity. R 38 R-38 Roof Attic RB Ceilings (below attic) Wood Framed Ceiling'-` ' 2x4 @,24 in: O:C: (�" R 381 Sheathinglnsulation - no sheathing/insul. - lnside Finish: Gypsum Board ( Inside Finish: Gypsum Board 1 k"�� ,.LIZ lj ,• Sheathing/Insulation: - no sheathing/insul. - �"�r H E I' S P R ti, N rino insulation E Cavity: - no insulation (vertical) - R Sheathing/Insulation: - no sheathing/insul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. (vertical) - Exterior Finish: 3 Coat Stucco SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab living 2760 247 None 0.8 No Slab 2 Garage 512 77 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED NOT REQUIRED --- Registration Number: 216-N0184611A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF113-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:53:41 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Date/Time: 22:45, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2U.xml CF1 R-PRF-NCB-01 Page 7 of 10 WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Standard 1 0.0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0 0.95 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a n/a HVAC SYSTEMS i_.t� j 01 `` r02.,t t 1*�`-� ��-:j1 i� ���- s03--, �� l� �� �% 17 041 �� �� sCi 05 06 07 Heating System E R�' R0 V"1ooli System C� Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC System1 Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 2760 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 95 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 11.7 14 Cooling Component 1-hers-cool Registration Number: 216-N0184611A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:53:41 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Date/Time: 22:45, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2U.xml CF1 R-10RF-NCEI-01 Page 8 of 10 HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Not Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in unconditioned Specified Lower 6 Attic Attic None Air Distribution attic Leakage Target System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%)� _ Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required. r" '� `1 11 ifI 6.0 ! ! 1.11 � IN,r:.1Not Required Not Required Not Required HVAC -FAN SYSTEMS \`A w.-� �" u -Z=; u u " `` Il " u `"` \ 01 i� IO2 r M V f L oO [03 rA 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 65 Exhaust 0 Required Registration Number: 216-N0184611A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-17 22:53:41 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-0RF-NCB-01 Project Name: Plan 2 Calculation Date/Time: 22:45, Tue, May 17, 2016 Page 9 of 10 Calculation Description: Title 24 Analysis Input File Name: 14023P2U.xml COOLING VENTILATION NONE C "Eu9T`�' L b HER 5 PROVIDE R Registration Number: 216-N0184611A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-17 22:53:41 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation DatefTime: 22:45, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2U.xml CF1 R-PI2F-NCB-61 Page 10 of 10 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Rudy Sains Company: Signature Date: Heritage Energy Group 2016-05-18 08:38:36 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949-584-1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to -the enforcement.agency.for approval with,this_building permit application. Responsible Designer Name: (('� r Re'sponsibleD�e`s�igner Signature: I (�-, l�a�Pi�afiru�v Dave Warren . {`� 11 t i �N r�'� n i ! 1 f Company: ' Date Signed: " 0 6-05 18 8:39:52� California West Communities Address: License: 5927 Priestly Drive, Suite 103 N/A City/State/Zip: Phone: Carlsbad, CA 92008 760-918-2824 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-N0184611A-000000000-0000 Registration Date/Time: 2016-05-18 0839:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 22:53:41 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 w/Bedroom 4 Calculation Date/Time: 23:05, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2UOpt.xml CFI R-PRF-NCB-01 Page 1 of 10 GENERAL INFORMATION 01 Project Name Plan 2 w/Bedroom 4 02 Calculation Description Title 24 Analysis 03 Project Location The Estates 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-2 (595c) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 2766 15 Number of Zones 1 16 Slab Area (FT2) 2766 17 Number of Stories 1 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 Glazing Percentage (%) 28.0% Detailed help on using the`CFAR Certificate of o Compliance is�il b w -a he Internet by either ' scanningthe QR code or�browsln to: ` Ic r http://%N".title24e,nergycode.org/t24help/cfl r.aspx `a. n k- t-t � rr` "R 0 V i D E R � COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-No184616A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 23:13:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 w/Bedroom 4 Calculation Date/Time: 23:05, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2UOpt.xml CFI R-PRF-NCB-01 Page 2 of 10 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.37 1.31 0.06 4.4% Space Cooling 102.64 105.76 -3.12 -3.0% IAQ Ventilation 1.05 1.05 0.00 0.0% Water Heating 10.22 5.27 4.95 48.4% PV Credit ---- 0.00 0.00 ---- North Facing - TOTAL 115.28 113.39 1.89 1.6% Space Heating 1.37 2.10 -0.73 -53.3% Space Cooling 102.64 100.91 1.73 1.7% IAQ Ventilation 1.05 1.05 0.00 0.0% Water Heating 10.22 5.27 4.95 48.4% PV Credit ---- 0.00 0.00 --- East Facing - TOTAL 115.28 109.33 5.95 5.2% Space Heating 1.37 1.75 -0.38 -27.7% Space Cooling IAQ Ventilation 102:64 ( 11.05 102:10!� t 1.05 C E 0.54 0.00 0.5% 0.0% Water Heating ttt 10.22. 1I 5.27y 4:95 48.4% PV Credit _--_} E R S P R'0.0�0 -) �l �{ } i � D E Tl p 0.00 ---- South Facing - TOTAL 115.28 110.17 5.11 4.4% Space Heating 1.37 0.87 0.50 36.5% Space Cooling 102.64 101.84 0.80 0.8% IAQ Ventilation 1.05 1.05 0.00 0.0% Water Heating 10.22 5.27 4.95 48.4% PV Credit ---- 0.00 0.00 --- West Facing - TOTAL 115.28 109.03 6.25 5.4% Registration Number: 216-N0184616A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 23:13:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 w/Bedroom 4 Calculation Date/Time: 23:05, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2UOpt.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins CFI R-PKF-NCB-01 Page 3 of 10 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 2 w/Bedroom 4 2766 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 living Conditioned HVAC System1 2766 13.5 DHW Sys 1 OPAQUE SURFACES +^ l7= 01 % , 021 03�= ( V 04 06 07 08 Name 'one t+ � IJ �Construction`,J f �Azimu4Fi I Orientation x i -Gross Area (ft2) Window Area (ft2) Tilt(deg) Front Wall living. E R M1R 19 Wall2 R NO' I I tFrontR 243 83 90 Left Wall living R-19 Wall 90 Left 285 129 90 Rear Wall living R-19 Wall 180 Back 729 294 90 Right Wall living R-19 Wall 270 Right 1269 268 90 garage wall2 living R-19 Wall 0 Front 320 0 90 Roof living R-38 Roof Attic RB 2766 garage wall right Garage Garage Ext Wall 270 Right 143 0 90 garage wall front Garage Garage Ext Wall 180 Back 304 0 90 garage wall left Garage Garage Ext Wall 90 Left 285 0 90 Exterior Wall Garage Garage Ext Wall 0 Front 1 0 90 Roof 2 Garage Garage Roof 521 Registration Number: 216-No184616A-000000000-0000 Registration Date/Time: 2016-05-1808:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 23:13:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 w/Bedroom 4 Calculaticn Date/Time: 23:05, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2U0pt.xml CFI R-PRF-NC6-01 Page 4 of 10 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 5 0.1 0.85 Yes No WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height (ft) Width(ft ) Multiplie r Area (ft2) U- factor SHG C Exterior Shading 9080 dr Window Front Wall (Front-0) 8.0 9.0 1 72.0 0.28 0.21 1626-3 Window Front Wall (Front-0) ---- ---- 1 11.0 0.27 0.23 3060-2 Window Left Wall (Left-90) 6.0 6.0 1 36.0 0.29 0.20 3020-2 Window Left Wall (Left-90) 2.0 6.0 1 12.0 0.27 0.23 4050 Window Left Wall (Left-90) ---- ---- 1 20.0 0.29 0.20 10020 Window Left Wall (Left-90) 2.0 10.0 1 20.0 0.27 0.23 2040-2 Window '.. Left Wall (Left-90) 4.0 4.0 1 16.0 0.29 0.20 5050 Window �f Left Wall '(L'ft-90) � �( _- 5.0 P t5:0.S 1 25.0 0.29 0.20 12080 dr Window , Rear Wall (Beck-180)' ) 1 - I a--- I 1 1 ., 96.0 0.28 0.21 16080 dr Window Rear Wall (Back-180) ,r - - .•., era w�"+ 8'.0 .. t 16.0 ... 9 128.0 0.28 0.21 3060-2 2 Window ~, �`i Rear' Wall tr(Back-180) V ; A ;-� V 8A L '� 9.0- 11�0.5 36.0 0.29 0.20 2020-6 Window Rear Wall (Back-180) 2.0 17.0 1 34.0 0.27 0.23 4060-2 Window Right Wall (Right-270) ---- ---- 1 48.0 0.29 0.20 4030-2 Window Right Wall (Right-270) ---- ---- 1 24.0 0.27 0.23 2020-2 Window Right Wall (Right-270) ---- ---- 1 8.0 0.27 0.23 2060-2 Window Right Wall (Right-270) ---- ---- 1 24.0 0.29 0.20 2030-2 Window Right Wall (Right-270) ---- ---- 1 12.0 0.27 0.23 2040 Window Right Wall (Right-270) ---- ---- 1 8.0 0.29 0.20 3050-2 Window Right Wall (Right-270) ---- ---- 1 30.0 0.29 0.20 3030-2 Window Right Wall (Right-270) - --- 1 18.0 0.27 0.23 12080 Window Right Wall (Right-270) 8.0 12.0 1 1 96.0 0.28 0.21 Registration Number: 216-No184616A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 23:13:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 w/Bedroom 4 Calculation Date/Time: 23:05, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2U0pt.xml CF1 R-PRF-NC6-01 Page 5 of 10 DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door 16080 garage wall front 128.0 1.00 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 r 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up 9080 dr 2 0.5 2 2 0 0 0 0 0 0 0 0 0 3060-2 0 0 0 0 0 0 0 0 0 0 0 0 0 3020-2 2, 0.5 2 2 0 0 0 0 0 0 0 0 0 10020 2 0.5 2 2 0 0 0 0 0 0 0 0 0 2040-2 2 0.5 2 2 0 0 0 0 0 0 0 0 0 5050 2 0.5 1-2 2,-ti 0, _ 0 .0� 0 0 0 0 0 0 16080 dr 3060-2 2 12 f 2 f� , _x 1 '0.5 L 10.:"� L ..2. © 11 1() 12__ , �`� 1 0 l� 0S ,_ ; � 0 0i7 � n oil N \ Oar ! 0 0 0 0 0 0 0 0 0 0 0 2020-6 2 0.5 r r2 �.. r-�2C-- r-0 r-d —2 1t 4 v1 0, . r.-« or-. 0 0 0 0 0 12080 2 ("5 42 "" ' ` 2 "' *0 ` } %-16 1W 0 r "" 01 ' 0 0 0 0 0 Registration Number: 216-N0184616A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 23:13:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 w/Bedroom 4 Calculation Date/Time: 23:05, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2U0pt.xml CF1 R-PRF-NCB-01 Page 6 of 10 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic floor - Cavity: - no insulation - Sheathinglnsulation - no sheathing/insul. - Garage Roof Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Attic Floor: - no attic floor - Cavity: R 38 R-38 Roof Attic RB Ceilings (below attic) Wod Fr oamed Ceiling,-2x4 @,24 in! O.C. R 38 Sheathinglnsulation - no sheathing/insul. - rInside Finish: Gypsum Board I( Inside Finish: Gypsum Board f7 !•Sheathing/Insulation: - no sheathing/insul. - p H E f" �. S {� t" R C ti Vno insul_ on E Cavity. - no insulation (vertical) - • R Sheathing/Insulation: - no sheathing/insul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. (vertical) - Exterior Finish: 3 Coat Stucco SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab living 2766 247 None 0.8 No Slab 2 Garage 512 77 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED NOT REQUIRED --- Registration Number: 216-N0184616A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS Inc. Report Generated at: 2016-05-17 23:13:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 w/Bedroom 4 Calculation Date/Time: 23:05, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2UOpt.xml CF1 R-PRF-NCB-01 Page 7 of 10 WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Standard 1 0.0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0 0.95 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a n/a _ _ " HVAC SYSTEMS ' f�`•., A` f..7► 1 f{ 01 r' .02 `\��`.-��+03- q 1� �4 i "-�- 117 1f04 4��s 05 06 07 H He Heating System E R S R "Cooling System t L.10 C� Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC System1 Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 2766 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 95 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 11.7 14 Cooling Component 1-hers-cool Registration Number: 216-N0184616A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 23:13:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 w/Bedroom 4 Calculation Date/Time: 23:05, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2U0pt.xml CF1 R-PRF-NC6-01 Page 8of10 HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Not Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in unconditioned Specified Lower 6 Attic Attic None Air Distribution attic Leakage Target System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%)_ s--. Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required � I i if I 6.0 I'U) 11 h�Not Required Not Required Not Required 11 it Ii 1. iI{i II I %I II 51 tl I II is ` HVAC -FAN SYSTEMS ` LI u ' 01 r7 i= (02 P" Phi V I fL..O t03 M 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 65 Exhaust 0 Required Registration Number: 216-No184616A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-17 23:13:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-NCB-G9 Project Name: Plan 2 w/Bedroom 4 Calculation Date/Time: 23:05, Tue, May 17, 2016 Page 9 of 10 Calculation Description: Title 24 Analysis Input File Name: 14023P2UOpt.xml COOLING VENTILATION NONE Cc:::N CERTS, nc. Registration Number: 216-N0184616A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-17 23:13:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 w/Bedroom 4 Calculation Date/Time: 23:05, Tue, May 17, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P2UOpt.xml CFI R-PRF-NCB=01 Page 10 of 10 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: �C"`�✓�acsav Rudy Sains Company: Signature Date: Heritage Energy Group 2016-05-18 08:38:36 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949-584-1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans'and specifications submitted to,the enforcement. agency. for approval with.this,building permit application. Responsible Designer Name: ResponsibleDesigner Signature: �avPi�i�vtefv '\\ I I I l C Dave Warren --, ':�) n f i f 0 Company: HERS Date Signed: " 2016-05 1 8:39:52�` California West Communities Address: License: 5927 Priestly Drive, Suite 103 N/A City/State/Zip: Phone: Carlsbad, CA 92008 760-918-2824 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-No184616A-000000000-0000 Registration Date/Time: 2016-05-1808:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-17 23:13:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 01:49, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CF1 R-PRF-NC9-01 Page 1 of 12 GENERAL INFORMATION 01 Project Name Plan 3 02 Calculation Description Title 24 Analysis 03 Project Location The Estates 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-2 (595c) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 2921 15 Number of Zones 2 16 Slab Area (FT2) 2528 17 Number of Stories 2 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 j Glazing Percentage (%) 35.0% Detailed help on using the CF-1R Certificate ofCompliana is�ilableviiaathe Internet by eitherscannil 91kNil e QRc d oin Qr�br�oust1g to f L }�,• 11 �' 11 Iri !lliil hftp://wmiw.title24energycode.org/t24help/cfl r.a` px ROVI DER ■ ❑ COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-N0184624A-000000000-0000 Registration Date/Time: 2016-05-1808:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 02:01:07 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 01:49, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CF1 R-PRiP-NCB-01 Page 2 of 12 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) FDesign Design Margin Improvement Space Heating 2.99 3.27 -0.28 -9.4% Space Cooling 114.52 118.69 -4.17 -3.6% IAQ Ventilation 0.91 0.91 0.00 0.0% Water Heating 9.67 4.99 4.68 48.4% PV Credit ---- 0.00 0.00 ---- North Facing - TOTAL 128.09 127.86 0.23 0.2% Space Heating 2.99 3.38 -0.39 -13.0% Space Cooling 114.52 100.38 14.14 12.3% IAQ Ventilation 0.91 0.91 0.00 0.0% Water Heating 9.67 4.99 4.68 48.4% PV Credit ---- 0.00 0.00 ---- East Facing - TOTAL 128.09 109.66 18.43 14.4% Space Heating 2.99 3.65 -0.66 -22.1% Space Cooling IAQ Ventilation 1<14'52 '� 0.91 98:39kk CE•� 0.91f 16.13 00 nc.68 14.1 % 0.0% Water Heating 9:67 �' 4.99 48.4% PV Credit J E l� R S ;<'+j ('S0.00-) 1'" [ � f� V i D E R 0.00 i.J� ---- South Facing - TOTAL 128.09 1107.94 20.15 15.7% Space Heating 2.99 2.57 0.42 14.0% Space Cooling 114.52 97.67 16.85 14.7% IAQ Ventilation 0.91 0.91 0.00 0.0% Water Heating 9.67 4.99 4.68 48.4% PV Credit ---- 0.00 0.00 ---- West Facing -TOTAL 128.09 106.14 21.95 17.1% Registration Number: 216-N0184624A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 02:01:07 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PR*F-NCB-Ul Project Name: Plan 3 Calculation Date/Time: 01:49, Wed, May 18, 2016 Page 3 of 12 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation • Window overhangs and/or fins BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 3 2921 1 3 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Main Conditioned HVAC SystemM1 2246 10.1 DHW Sys 1 Casita Conditioned HVACSystemC2 675 I M 10.1 DHW Sys 1 HER 5 PROVIDE R Registration Number: 216-N0184624A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-18 02:01:07 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 01:49, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CFI R-PRF-NCY-01 Page 4 of 12 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft) Tilt(deg) Front Wa112 Main R-19 Wall 0 Front 192 84.5 90 Left Wa112 Main R-19 Wall 90 Left 737 138 90 Rear Wa112 Main R-19 Wall 180 Back 404 338 90 Right Wa112 Main R-19 Wall 270 Right 737 198 90 garage wall2 Main R-19 Walli 0 Front 140 0 90 Roof2 Main R-38 Roof Attic RB 2246 Interior Surface Main»Garage R-19 Wall1 120 Front Wall Casita R-19 Wall 0 Front 364 54 90 Left Wall Casita R-19 Wall 90 Left 485 48 90 Rear Wall Casita R-19 Wall 180 Back 566 92 90 Right Wall Casita R-19 Wall 270 Right 737 69 90 garage wall Casita R-19 Wall 0 Front 100 0 90 Roof Casita " �R=38RoofAtticR6 �`�� y 'r j 393 Raised Floor f Casita --a R?19 Floor No Crawlspace I Exterior Wall Garaged `-` ` L--" u Garage Ezt Wall U t 2701/ a U Right^ t ' 270 0 90 Exterior WallF Garage, Garage Ext Wall ( �Q ,, Front] 323 0 90 Exterior WallL Garage Garage Ext Wall 90 Left 293 0 90 Exterior Wall Garage Garage Ext Wall 180 Back 10 0 90 Roofg Garage GarageRoof 1 1 519 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 3 0.1 0.85 Yes No Registration Number: 216-N0184624A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 02:01:07 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Description: Title 24 Analysis Calculation Date/Time: 01:49, Wed, May 18, 2016 Input File Name: 14023P3U.xml CFI R-PRP-NCB-01 Page 5 of 12 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height (ft) Width(ft ) Multiplie r Area (ft) U- factor SHG C Exterior Shading 9080- Window Front Wa112 (Front-0) 8.0 9.0 1 72.0 0.28 0.21 2626--2 Window Front Wall2 (Front-0) ---- ---- 1 12.5 0.27 0.23 3080 Window Left Wa112 (Left-90) 8.0 3.0 1 24.0 0.34 0.16 3020 Window Left Wa112 (Left-90) ---- ---- 1 6.0 0.27 0.23 4060-2 Window Left Wa112 (Left-90) ---- ---- 1 48.0 0.29 0.20 4020-2 Window Left Wa112 (Left-90) ---- ---- 1 16.0 0.27 0.23 3040---2 Window Left Wall2 (Left-90) 4.0 6.0 1 24.0 0.29 0.20 2040 Window Left Wa112 (Left-90) 4.0 2.0 1 8.0 0.29 0.20 3040 Window Left Wa112 (Left-90) ---- ---- 1 12.0 0.29 0.20 16080 Window Rear Wa112 (Back-180) 8.0 16.0 1 128.0 0.28 0.21 12080 Window Rear Wa112 (Back-180) ---- ---- 1 96.0 0.28 0.21 9080 Window . ' . Rear Wa112 (Back _180) - - 1 72.0 0.28 0.21 Transom Window Rear Wal12 (Back-180)L-, t �� L -� 2.0 21 0;� 1 42.0 0.27 0.23 2060-2 Window \',,_Right Wa112 (Right-270)_J ,)�i r r # j �--1 24.0 0.29 0.20 2020-2 Window LRight�WallZ Right-270) M � 1" y / i '1 -_ - C3 1 8.0 0.27 0.23 2030 Window ` Ftght'Wall2 (RigFt'270) 1 6.0 0.29 0.20 4050 Window Right Wa112 (Right-270) ---- ---- 1 20.0 0.29 0.20 2050-2 Window Right Wa112 (Right-270) ---- ---- 1 20.0 0.29 0.20 9080 ddr Window Right Wa112 (Right-270) ---- ---- 1 72.0 0.28 0.21 3080-2 frdr Window Right Wa112 (Right-270) 8.0 6.0 1 48.0 0.34 0.16 3050-2 Window Front Wall (Front-0) 5.0 6.0 1 30.0 0.27 0.23 30802 Window Front Wall (Front-0) 8.0 3.0 1 24.0 0.34 0.16 3080-1 frdr Window Left Wall (Left-90) 8.0 3.0 1 24.0 0.34 0.16 20302 Window Left Wall (Left-90) ---- ---- 1 6.0 0.29 0.20 3060 Window Left Wall (Left-90) 6.0 3.0 1 18.0 0.29 0.20 90802 Window Rear Wall (Back-180) ---- ---- 1 72.0 0.28 0.21 2050-2 2 Window Rear Wall (Back-180) 5.0 4.0 1 20.0 0.29 0.20 2060-2 2 Window Right Wall (Right-270) ---- ---- 1 24.0 0.29 0.20 3050-2 2 Window Right Wall (Right-270) ---- I ---- 1 30.0 0.29 0.20 Registration Number: 216-No184624A-000000000-0000 Registration Date/Time: 2016-05-1808:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 02:01:07 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 01:49, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml 3050 Window Right Wall (Right-270) I ---- I ---- 1 1 1 15.0 1 0.27 1 0.23 CFI R-PkF-NCB=01 Page 6of12 DOORS 01 02 03 04 Name Side of Building Area (W) U-factor Door Right Wa112 28.0 0.50 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 9080- 2 1 2 2 0 0 0 0 0 0 0 0 0 3080 12 1 10 10 0 0 0 0 0 0 0 0 0 3040 --- 2 2 1 2 2 0 0 0 0 0 0 0 0 0 2040 2 1 2 2 0 0 0 0 0 0 0 0 0 16080 12 1 `'10 f 716'-" OF)" --I ('0 01, �_ 0�� 0 0 0 0 0 Transom 2' 0 11t t o �� _ oil 4 19 0 0 0 0 0 0 3080-2 frdr 10 �1 ""``-'"6`--' 6`'-" —0� ` 0 "" ` ,{% 0`" " 0-- ' 0 0 0 0 0 3050-2 10 `` 1„ ii6 C i?-"% 6 . ? I 0 11-1 %..16 V t O—.0 C: Or% 0 0 0 0 0 30802 10 1 6 6 0 0 0 0 0 0 0 0 0 3080-1 frdr 10 1 6 6 0 0 0 0 0 0 0 0 0 3060 10 1 6 6 0 0 0 0 0 0 0 0 0 2050-2 2 2 1 2 2 0 0 0 0 0 0 0 0 I0 Registration Number: 216-N0184624A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 02:01:07 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 01:49, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CF1 R-Ph2F-NCB=01 Page 7 of.12 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic Floor - Cavity: - no insulation - Sheathinglnsulation - no sheathing/insul. - GarageRoof Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Wall Exterior.Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Attic Floor: - no attic floor - Cavity: R 38 R-38 Roof Attic RB Ceilings (below attic) �--�r--- Wood Framed Ceiling`'" r1 2x4 @ 24'in: O.0 - R 38 Sheathinglnsulation - no sheathing/insul. - Inside Finish: Gypsum Board Inside Finish: Gypsum Board :Sheathing/Insulation: - no sheathing/insul. - / H E R S �J i R I E: Cavity: R 19 R Sheathing/Insulation: - no sheathing/insul. - R-19 Walll Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Walll Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Other Side Finish: Gypsum Board Floor Surface: Carpeted Concrete Fill: - no concrete fill - Floor Deck: Wood Siding/sheathing/decking Cavity. R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Floor No Crawlspace Exterior Floors Wood Framed Floor 2x6 @ 16 in. O.C. R 19 Exterior Finish: - select finish - Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: - no insulation (vertical) - - no insulation Sheathing/Insulation: - no sheathing/insul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. (vertical) - Exterior Finish: 3 Coat Stucco Registration Number: 216-N0184624A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 02:01:07 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 01:49, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CF1 R-PI2F-NCB-d1 Page8of12 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab2 Main 2246 255 None 0.8 No Slab Casita 282 40 None 0.8 No Slab -on -Grade Garage 519 122 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED NOT REQUIRED --- WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 ! (Standard, c-....= 1 0.0% /! G1 i i 7! I I i I l) 1 I I I I r---\ WATER HEATERS, to f 1 1 \�__ E i _ t f ! 01 02 * d s--03 r-+. I... r"% 04, w �,..t ♦. ' �w05 , r- 06 07 08 Name Heater Element Type lit F - $ % -} Tank Type Tank Volume' (gal) EnergyFactcr or%- Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0 0.95 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a n/a Registration Number: 216-N0184624A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-18 02:01:07 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 01:49, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CF1 R-PRF-NCB=01 Page 9 of 12 HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC SystemM1 Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 2246 HVAC SystemC2 Heat Pump Heating and Cooling Heat Pump System 2 No Heat Pump System No HVAC HVAC 675 System 2 SystemC2-dist SystemC2-fan HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - HEATING SYSTEMS: Heat Pumps 01 02 03 04� 05 ` 06 07 ({�! He�atm II � �Cap 17 Cooling SEER Type iEfficiencEERName y ap4) Heat Pump System 2 DuctlessHeatPump3 .Heating side of , ductless mini -split heat pump F 7+7 HSPF E K P p 35000 U R� v 15000 4 ID E 16 13 HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 12.5 15 Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Not Required Required Required Heat Pump System 2-hers-cool Not Required Not Required Required Required Registration Number: 216-No184624A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 02:01:07 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 01:49, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CFI R-PRP-NCB-01 Page 10 of 12 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in unconditioned Specified Lower 6 Attic Attic None Air Distribution attic Leakage Target System 1-hers-dist HVAC HVAC SystemC2-dist Ducts located in unconditioned Sealed and tested 8 Attic Attic None SystemC2-dist-hers- attic dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required HVAC SystemC2-dist-hers-dist Not Required Not Required Not Required Not Required HVAC -FAN SYSTEMS e - it 01 i 02 1 7NI "1`1 11 03 04 Name *.�` t '~" �^� Type%` tr U u Z 'w I/ Far; Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan' � *...r V [ j� �0:58 Required HVAC SystemC2-fan Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 HVAC SystemC2-fan-hers-fan Not Required IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 59 Exhaust 0 Required Registration Number: 216-N0184624A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 02:01:07 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-NCB-01 Project Name: Plan 3 Calculation Date/Time: 01:49, Wed, May 18, 2016 Page 11 of 12 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml COOLING VENTILATION NONE ERS-� C (CERTSg nco , 20 � 5 PROVI DER Registration Number: 216-N0184624A-000000000-0000 Registration Date/Time: 2016-05-18 08:39:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-18 02:01:07 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 01:49, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3U.xml CF1 R-PRF-NCE9-01 Page 12 of 12 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: %�"✓�acsca Rudy Sains Company: Signature Date: Heritage Energy Group 2016-05-18 08:38:36 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949-584-1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to,the enforcement agency,for approval with,this,building permit application. Responsible Designer Name: ResponsiibleDbsiioner Signature: Dave Warren ^C`�.11��-! I I r--� n Company: HERS Date Signed: a ER 2016-05 1 08 8:39:52� California West Communities Address: License: 5927 Priestly Drive, Suite 103 N/A City/State/Zip: Phone: Carlsbad, CA 92008 760-918-2824 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-N0184624A-000000000-0000 Registration Date/Time: 2016-05-1808:39:52 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 02:01:07 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Bedroom 3 Calculation Date/Time: 11:45, Wed, Jun 15, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPTxml CF1 R-PRF-NCd-01 Page 1 of 12 GENERAL INFORMATION 01 Project Name Plan 3 w/Bedroom 3 02 Calculation Description Title 24 Analysis 03 Project Location The Estates 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-2 (595c) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 3181 15 Number of Zones 2 16 Slab Area (FT2) 2788 17 Number of Stories 2 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 Glazing Percentage (%) 27.5% Detailed help on using the CF-1 R Certificate of Compliance is available via,the Internet by either r scanning the QR code or.browsin to: ^� r http://www.title24e.nergycode.org/t24help/cfl r.aspx 4 to C- I)N,� IF IN0VI D ER Q COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-No184672B-000000000-0000 Registration Date/Time: 2016-06-1514:58:26 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-06-15 11:54:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Bedroom 3 Calculation Date/Time: 11:45, Wed, Jun 15, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPT.xml CFI R-PRF-NCB-01 Page 2 of 12 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 2.70 2.89 -0.19 -7.0% Space Cooling 110.33 112.05 -1.72 -1.6% IAQ Ventilation 0.87 0.87 0.00 0.0% Water Heating 8.88 4.58 4.30 48.4% PV Credit ---- 0.00 0.00 ---- North Facing -TOTAL 122.78 120.39 2.39 1.9% Space Heating 2.70 2.92 -0.22 -8.1% Space Cooling 110.33 94.51 15.82 14.3% IAQ Ventilation 0.87 0.87 0.00 0.0% Water Heating 8.88 4.58 4.30 48.4% PV Credit ---- 0.00 0.00 ---- East Facing - TOTAL 122.78 102.88 19.90 16.2% Space Heating 2:70 . 3.37 -0.67 -24.8% Space Cooling IAQ Ventilation - 110.33 5` 49� 0.8;C R�19458 14.84 0.00 13.5% 0.0% Water Heating8.88{ r Q0.87 . 4;30 48.4% PV Credit --j �^j 0. 7) V I C" D E R 0.00 C fl ---- South Facing -TOTAL 122.78 104.31••'/ 18.47 15.0% Space Heating 2.70 2.11 0.59 21.9% Space Cooling 110.33 90.94 19.39 17.6% IAQ Ventilation 0.87 0.87 0.00 0.0% Water Heating 8.88 4.58 4.30 48.4% PV Credit ---- 0.00 0.00 ---- West Facing - TOTAL 122.78 98.50 24.28 19.8% Registration Number: 216-NO1846728-000000000-0000 Registration Date/Time: 2016-06-15 14:58:26 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-06-15 11:54:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-NCB-Q4 Project Name: Plan 3 w/Bedroom 3 Calculation Date/Time: 11:45, Wed, Jun 15, 2016 Page 3 of 12 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPT.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation • Window overhangs and/or fins BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 3 w/Bedroom 3 3181 1 3 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Main Conditioned HVAC SystemM1 2506 10.1 DHW Sys 1 Casita Conditioned r~ HVAC SystemC2 �.'675r� n 10.1 DHW Sys 1 Q�'- FOR, � L' Lz= RCO HER 5 PROVIDER Registration Number: 216-N0184672B-000000000-0000 Registration Date/Time: 2016-06-15 14:58:26 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-06-15 11:54:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Bedroom 3 Calculation Date/Time: 11:45, Wed, Jun 15, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPT.xml CF1 R-PRF-NCEL01 Page 4 of 12 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft2) Tilt(deg) Front Wa112 Main R-19 Wall 0 Front 192 12.5 90 Left Wa112 Main R-19 Wall 90 Left 737 152 90 Rear Wa112 Main R-19 Wall 180 Back 404 338 90 Right Wa112 Main R-19 Wall 270 Right 737 180 90 garage wall2 Main R-19 Walll 0 Front 140 0 90 Roof2 Main R-38 Roof Attic RB 2506 Interior Surface Main»Garage R-19 Wall1 120 Front Wall Casita R-19 Wall 0 Front 364 54 90 Left Wall Casita R-19 Wall 90 Left 485 48 90 Rear Wall Casita R-19 Wall 180 Back 566 20 90 Right Wall Casita R-19 Wall 270 Right 737 69 90 garage wall Casita R-19 Wall 0 Front 100 0 90 Roof Casita - R-38Roof Attic RB .. 393 Raised Floor Casita R119 Floor No Crawlspace .0 Exterior Wall Ga`rage� '�� �.t a Garage EhWall' I C:�2701/ I u Righf { ' 270 0 90 Exterior WallF Garage H Garage Ext Wall K ( _) *VO 1 I ,) Front 323 0 90 Exterior WaIIL Garage Garage Ext Wall 90 Left 293 0 90 Exterior Wall Garage Garage Ext Wall 180 Back 10 0 90 Roofg Garage GarageRoof 519 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 3 0.1 0.85 Yes No Registration Number: 216-No184672B-000000000-0000 Registration Date/Time: 2016-06-15 14:58:26 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-06-15 11:54:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Bedroom 3 Calculation Date/Time: 11:45, Wed, Jun 15, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPT.xml CF1 R-PRF-NCBb1 Page 5 of 12 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height (ft) Width(ft ) Multiplie r Area (ft) U- factor SHG C Exterior Shading 2626--2 Window Front Wall2 (Front-0) ---- ---- 1 12.5 0.27 0.23 3080 Window Left Wa112 (Left-90) 8.0 3.0 1 24.0 0.34 0.16 3020 Window Left Wa112 (Left-90) ---- ---- 1 6.0 1 0.27 0.23 4060-2 Window Left Wa112 (Left-90) ---- ---- 1 48.0 0.29 0.20 4020-2 Window Left Wa112 (Left-90) ---- ---- 1 16.0 0.27 0.23 3040/2040 Window Left Wa112 (Left-90) 4.0 5.0 1 20.0 0.29 0.20 2040 Window Left Wa112 (Left-90) 4.0 2.0 1 8.0 0.29 0.20 5060 Window Left Wa112 (Left-90) ---- ---- 1 30.0 0.29 0.20 16080 Window Rear Wa112 (Back-180) 8.0 16.0 1 128.0 0.28 0.21 12080 Window Rear Wa112 (Back-180) ---- ---- 1 96.0 0.28 0.21 9080 Window Rear Wa112 (Back-180) ---- ---- 1 72.0 0.28 0.21 Transom Window n5pr Wa112 (Back-180)_ _� � 2.0 21.0 1 42.0 0.27 0.23 2060-2 Window Right Wa112'(Right-270)" #(�% �; -` - (; j�1 24.0 0.29 0.20 2020-2 Window�� ��_Right W6112 (Right-270)� r ,,%I a r ;--- `11r y 8.0 0.27 0.23 2030 Window LRight Wall2 (Right-270) f7 r1V i.-ti •. 1 us 1f -% --Z- l' 1 6.0 0.29 0.20 4050 Window ~ ' Righf Wa112'(RigHt=270) +"` -- 1 20.0 0.29 0.20 2050-2 Window Right Wa112 (Right-270) ---- ---- 1 20.0 0.29 0.20 9080 ddr Window Right Wa112 (Right-270) ---- ---- 1 72.0 0.28 0.21 6050 Window Right Wa112 (Right-270) ---- ---- 1 30.0 0.29 0.20 3050-2 Window Front Wall (Front-0) 5.0 6.0 1 30.0 0.27 0.23 30802 Window Front Wall (Front-0) 8.0 3.0 1 24.0 0.34 0.16 3080-1 frdr Window Left Wall (Left-90) 8.0 3.0 1 24.0 0.34 0.16 20302 Window Left Wall (Left-90) ---- ---- 1 6.0 0.29 0.20 3060 Window Left Wall (Left-90) 6.0 3.0 1 18.0 0.29 0.20 2050-2 2 Window Rear Wall (Back-180) 5.0 4.0 1 20.0 0.29 0.20 2060-2 2 Window Right Wall (Right-270) ---- ---- 1 24.0 0.29 0.20 3050-2 2 Window Right Wall (Right-270) ---- -- - 1 30.0 0.29 0.20 3050 Window Right Wall (Right-270) ---- - 1 15.0 0.27 1 0.23 Registration Number: 216-N0184672B-000000000-0000 Registration Date/Time: 2016-06-15 14:58:26 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-06-15 11:54:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Bedroom 3 Calculation Date/Time: 11:45, Wed, Jun 15, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPT.xml CF1 R-PRF-NCB-O'1 Page 6 of 12 DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door Right Wa112 28.0 0.50 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 3080 12 1 10 10 0 0 0 0 0 0 0 0 0 3040/2040 2 1 2 2 0 0 0 0 0 0 0 0 0 2040 2 1 2 2 0 0 0 0 0 0 0 0 0 16080 12 1 10 10 0 0 0 0 0 0 0 0 0 Transom 2 1 2 2 0 0 0 0 0 0 0 0 0 3050-2 10 1 �--_�6 6�� r�Or, —0 , 0� 0 0 0 0 0 0 30802 10 1 6 G1 �6 '---,0. L) 0 �� 0 i i r" -� 0� 0 0 0 0 0 3080-1 frdr ,10 < , ,\\ 1 ti� .-6" �1,6_ �0 j 11 0� 17 Oil � � 11 0 .� 0 0 0 0 0 3060 10 ':1 16 r- T-% 6 C- t-0, t"'1 0,. � 0 0 0 0 0 0 2050-2 2 2 1' -2 "- %2 `' ' 0 ' ' `"0 " 0'`- A— 0" 0 0 0 0 0 Registration Number: 216-N0184672B-000000000-0000 Registration Date/Time: 2016-06-15 14:58:26 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-06-15 11:54:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Bedroom 3 Calculation Date/Time: 11:45, Wed, Jun 15, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPT.xml CFI R-PRF-NCS-01 Page 7 of 12 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic floor - Cavity: - no insulation - Sheathinglnsulation - no sheathing/insul. - GarageRoof Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Attic Floor. - no attic floor - Cavity: R 38 R-38 Roof Attic RB Ceilings (below attic) Wood Framed Ceiling �'"' ' ',2x4 @ 24'ih; O.C: "'- R 38,1 Sheathinglnsulation - no sheathing/insul. - • Inside Finish: Gypsum Board I Inside Finish: Gypsum Board f] •rSheathing/Insulation: - no sheathing/insul. - Cavity: R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Walll Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Wall'! Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Other Side Flnish: Gypsum Board Floor Surface: Carpeted Concrete Fill: - no concrete fill - Floor Deck. Wood Siding/sheathing/decking Cavity: R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Floor No Crawlspace Exterior Floors Wood Framed Floor 2x6 @ 16 in. O.C. R 19 Exterior Finish: - select finish - Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: - no insulation (vertical) - - no insulation Sheathing/Insulation: - no sheathing/insul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. (vertical) - Exterior Finish: 3 Coat Stucco Registration Number: 216-N0184672B-000000000-0000 Registration Date/Time: 2016-06-15 14:58:26 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-06-15 11:54:04 < V CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Bedroom 3 Calculation Date/Time: 11:45, Wed, Jun 15, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPT.xml CF1 R-PRF-NC9-01 Page 8 of 12 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab2 Main 2506 255 None 0.8 No Slab Casita 282 40 None 0.8 No Slab -on -Grade Garage 519 122 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED NOT REQUIRED --- WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 (Standard, t.-= - tt 1 0.0% /r G-1 t4 I l l I J1 !Y \I.— It r �_r WATER HEATERS 01 02 03 ! t er• r1 04 1—R { •► — 1! 05 , ♦ t tr-•.. r 06 t-N 07 08 Name Heater Element Type Tank Type Tank Volume-" (gal) EnergyFactcr or''- Efficiency f '% Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0 0.95 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a n/a Registration Number: 216-N0184672B-000000000-0000 Registration Date/Time: 2016-06-15 14:58:26 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-06-15 11:54:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Bedroom 3 Calculation Date/Time: 11:45, Wed, Jun 15, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPT.xml CF1 R-PRF-NCB-0q Page 9 of 12 HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC SystemM1 Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 2506 HVAC SystemC2 Heat Pump Heating and Cooling Heat Pump System 2 No Heat Pump System No HVAC HVAC 675 System 2 SystemC2-dist SystemC2-fan HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - HEATING SYSTEMS: Heat Pumps 01 02 _ 03 _ _ 04 _ 05 06 07 S/ l� Heating Cooling SEER EER Name f .Type 'Efficiency �� Cap 47 .. _ Cap t17 Y'� Heat Pump System 2 DuctlessHeatPump�.Heating side of ductless mini -split heat K HSF �-} ^3 r35.000y � I ^y E150 16 13 pump [� �` t 1 V Y L J HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 12 14 Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Not Required Required Required Heat Pump System 2-hers-cool Not Required Not Required Required Required Registration Number: 216-N0184672B-000000000-0000 Registration Date/Time: 2016-06-15 14:58:26 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-06-15 11:54:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Bedroom 3 Calculation Date/Time: 11:45, Wed, Jun 15, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPT.xml CF1 R-PRF-NC6-01 Page 10 of 12 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in unconditioned Specified Lower 6 Attic Attic None Air Distribution attic Leakage Target System 1-hers-dist HVAC HVAC SystemC2-dist Ducts located in unconditioned Sealed and tested 8 Attic Attic None SystemC2-dist-hers- attic dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply [Not Air Distribution System 1-hers-dist Required 6.0 Not Required Required Not Required HVAC SystemC2-dist-hers-dist Not Required Not Required Not Required Not Required HVAC -FAN SYSTEMS I ll D7 n 01 f_ 04 Name ' `,� '`` '�-4 Type~----:::3 f---:::3 U 1-� Z=-~' Ll Fari,P6wer(MA91CFM) HERS Verification HVAC Fan 1 V Single Speed PSC Fu nace Fant K U V 1 U '0.58 H Required HVAC SystemC2-fan Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 HVAC SystemC2-fan-hers-fan Not Required IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 62 Exhaust 0 Required Registration Number: 216-N0184672B-000000000-0000 Registration Date/Time: 2016-06-15 14:58:26 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-06-15 11:54:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-NCB-01 Project Name: Plan 3 w/Bedroom 3 Calculation Date/Time: 11:45, Wed, Jun 15, 2016 Page 11 of 12 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPTxml TOOLING VENTILATION NONE 1-7 d(ol I HER 5 PROVI DER Registration Number: 216-N0184672B-000000000-0000 Registration Date/Time: 2016-06-15 14:58:26 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-06-15 11:54:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Bedroom 3 Calculation Date/Time: 11:45, Wed, Jun 15, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3UOPTxml CF1 R-ORF-NCB-01 Page 12 of 12 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Rudy Sains Company: Signature Date: Heritage Energy Group 2016-06-15 14:57:06 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949-584-1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to.,the enforcement agency for approval with,this.building permit application. Responsible Designer Name: I � � Responsibleb,esigner Signature: A\ H 1 11 J� (C: Dave Warren C`�.t 1 t� ;'. I �--, . , r'y Company: HERS Date Signed: At 2016-06 15 14: 8:26� California West Communities Address: License: 5927 Priestly Drive, Suite 103 N/A City/State/Zip: Phone: Carlsbad, CA 92008 760-918-2824 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-No184672B-000000000-0000 Registration Date/Time: 2016-06-15 14:58:26 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-06-15 11:54:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Slimline A/C Calculation Date/Time: 09:58, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3USEER14.xmi CF1 R-PRF-NC9-01 Page 1 of 12 GENERAL INFORMATION 01 Project Name Plan 3 w/Slimline A/C 02 Calculation Description Title 24 Analysis 03 Project Location The Estates 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-2 (595c) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 2921 15 Number of Zones 2 16 Slab Area (FT2) 2528 17 Number of Stories 2 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 j Glazing Percentage (%) 35.0% Detailed help on using the CF-1R Certificate ofCompliance �is available v�the Internet by either '+^, scanning `the QR code �o�r brost�g�to j" o ko 4helcfl ca http://www.title24energycode.org/t2p/spx COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-N0184696A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 10:08:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Slimline A/C Calculation Date/Time: 09:58, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3USEER14.xml CF1 R-FRF-NCB-01 Page 2 of 12 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 2.45 2.80 -0.35 -14.3% Space Cooling 108.96 113.13 -4.17 -3.8% IAQ Ventilation 0.91 0.91 0.00 0.0% Water Heating 9.67 4.99 4.68 48.4% PV Credit ---- 0.00 0.00 ---- North Facing - TOTAL 121.99 121.83 0.16 0.1% Space Heating 2.45 2.77 -0.32 -13.1% Space Cooling 108.96 97.93 11.03 10.1 % IAQ Ventilation 0.91 0.91 0.00 0.0% Water Heating 9.67 4.99 4.68 48.4% PV Credit ---- 0.00 0.00 ---- East Facing - TOTAL 121.99 106.60 15.39 12.6% Space Heating 2.45 3.13 -0.68 -27.8% Space Cooling IAQ Ventilation - 108.96 0.91 97:18= C E D 0.911 11.78 00 10.8% 0.0% Water Heating9:67 f 4.99- n68 c 48.4% PV Credit -j E i.J R S P R0.0`^+i V I D 1 f E R 0.00 I1 ---- South Facing - TOTAL 121.99 106.21/ 15.78 12.9% Space Heating 2.45 2.22 0.23 9.4% Space Cooling 108.96 94.50 14.46 13.3% IAQ Ventilation 0.91 0.91 0.00 0.0% Water Heating 9.67 4.99 4.68 48.4% PV Credit ---- 0.00 0.00 ---- West Facing - TOTAL 121.99 102.62 19.37 15.9% Registration Number: 216-No184696A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 10:08:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-NCB-01 Project Name: Plan 3 w/Slimline A/C Calculation Date/Time: 09:58, Wed, May 18, 2016 Page 3 of 12 Calculation Description: Title 24 Analysis Input File Name: 14023P3USEER14.xm1 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation • Window overhangs and/or fins BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 3 w/Slimline A/C 2921 1 3 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone'Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Main Conditioned HVAC SystemM1 2246 10.1 DHW Sys 1 Casita Conditioned HVACsSysjemC2r__ r .,� �.6 5',- 10.1 DHW Sys 1 � co �� ���,���� a �o ur� HERS PROVIDER Registration Number: 216-N0184696A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-18 10:08:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Slimline A/C Calculation Date/Time: 09:58, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3USEER14.xml CF1 R-PRF-NCB-01 Page 4 of 12 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window Area (ft2) Tilt(deg) Front Wa112 Main R-21 Wall 0 Front 192 84.5 90 Left Wa112 Main R-21 Wall 90 Left 737 138 90 Rear Wa112 Main R-21 Wall 180 Back 404 338 90 Right Wa112 Main R-21 Wall 270 Right 737 198 90 Roof2 Main R-38 Roof Attic RB 2246 Interior Surface Main»Garage R-21 Wall1 120 Front Wall Casita R-21 Wall 0 Front 364 54 90 Left Wall Casita R-21 Wall 90 Left 485 48 90 Rear Wall Casita R-21 Wall 180 Back 364 92 90 Right Wall Casita R-21 Wall 270 Right 485 69 90 Roof Casita R-38 Roof Attic RB 393 Raised Floor Casita R-19 Floor No Crawlspace 111 Exterior WallR Garage ] I Garage EA Wall ^))'' r210 t Right �w. 270 0 90 Exterior WallF Garage ,Garage ExtWall�� '-�0; ( Fronts 323 0 90 Exterior WaIIL Ga`raget ,=�-i U Garage Ezt'Wall t "t=901/ 293 0 90 Exterior Wall Garage. Ga"r`age Ext Wall t I,� ';180 ! ,> jaack� 10 0 90 Roofg Garage GarageRoof 1 1 519 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 3 0.1 0.85 Yes No Registration Number: 216-N0184696A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 10:08:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Slimline A/C Calculation Date/Time: 09:58, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3USEER14.xml CF1 R-PRF-NCB-01 Page 5 of 12 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height (I t) Width(ft ) Multiplie r Area (ft2) U- factor SHG C Exterior Shading 9080- Window Front Wa112 (Front-0) 8.0 9.0 1 72.0 0.28 0.21 2626--2 Window Front Wa112 (Front-0) ---- ---- 1 12.5 0.27 0.23 3080 Window Left Wa112 (Left-90) 8.0 3.0 1 24.0 0.34 0.16 3020 Window Left Wa112 (Left-90) ---- ---- 1 6.0 0.27 0.23 4060-2 Window Left Wa112 (Left-90) ---- ---- 1 48.0 0.29 0.20 4020-2 Window Left Wa112 (Left-90) ---- ---- 1 16.0 0.27 0.23 3040 --- 2 Window Left Wa112 (Left-90) 4.0 6.0 1 24.0 0.29 0.20 2040 Window Left Wa112 (Left-90) 4.0 2.0 1 8.0 0.29 0.20 3040 Window Left Wall2 (Left-90) ---- ---- 1 12.0 0.29 0.20 16080 Window Rear Wa112 (Back-180) 8.0 16.0 1 128.0 0.28 0.21 12080 Window Rear Wa112 (Back-180) ---- ---- 1 96.0 0.28 0.21 9080 Window, Rear Wa112 (Back-180) - - 1 72.0 0.28 0.21 Transom Window I Rear Wall2 (Back-180) L.-., J L)) ( F 2.0 ( 2VO'� 1 42.0 0.27 0.23 2060-2 Window ` \�-Righf W6112'(Right-270)' r ,1� yj- ( - � 1fy 24.0 0.29 0.20 2020-2 Window LRightAWall2=(Right-270) iC i T �r'`y -Y - my 1 8.0 0.27 0.23 2030 Window ` ' Right Wa112 (RigHt'270) '"� -- - 1 6.0 0.29 0.20 4050 Window Right Wa112 (Right-270) ---- ---- 1 20.0 0.29 0.20 2050-2 Window Right Wa112 (Right-270) ---- ---- 1 20.0 0.29 0.20 9080 ddr Window Right Wa112 (Right-270) 8.0 9.0 1 72.0 0.28 0.21 3080-2 frdr Window Right Wa112 (Right-270) 8.0 6.0 1 48.0 0.34 0.16 3050-2 Window Front Wall (Front-0) 5.0 6.0 1 30.0 0.27 0.23 30802 Window Front Wall (Front-0) 8.0 3.0 1 24.0 0.34 0.16 3080-1 frdr Window Left Wall (Left-90) 8.0 3.0 1 24.0 0.34 0.16 20302 Window Left Wall (Left-90) ---- ---- 1 6.0 0.29 0.20 3060 Window Left Wall (Left-90) ---- ---- 1 18.0 0.29 0.20 90802 Window Rear Wall (Back-180) 8.0 9.0 1 72.0 0.28 0.21 2050-2 2 Window Rear Wall (Back-180) 5.0 4.0 1 20.0 0.29 0.20 2060-2 2 Window Right Wall (Right-270) ---- ---- 1 24.0 0.29 0.20 3050-2 2 Window Right Wall (Right-270) ---- ---- 1 30.0 0.29 0.20 Registration Number: 216-N0184696A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 10:08:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Slimline A/C Calculation Date/Time: 09:58, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3USEER14.xml 3050 Window Right Wall (Right-270) I --- --- 1 1 15.0 1 0.27 1 0.23 CF1 R-P(RF-NCB=01 Page 6 of 12 DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door Right Wa112 28.0 0.50 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up 9080- 2 1 2 2 0 0 0 0 0 0 0 0 0 3080 12 1 10 10 1 0 0 0 0 0 0 0 0 3040 --- 2 2 1 2 2 0 0 0 0 0 0 0 0 0 2040 2 1 2 2 0 0 0 0 0 0 0 0 0 16080 12 1 f -'--10'---' � � /1.0"-'w" : 7 1 F) Fo K7 011 �_ � 9�" 0 0 0 0 0 Transom 2 mi [ 1 0 011 11 1€ 0' 0 0 0 0 0 9080 ddr 2 `' ,`� �1 2� J' - 2'" -0' _ 0`" ` j/ 0" 0_" "' 0 0 0 0 0 3080-2 frdr 10 -'_1 171116 C M 6 f" 1 r 5 Co V 1 O..i c 0'-% 0 0 0 0 0 3050-2 10 1 6 6 1 0 0 0 0 0 0 0 0 30802 10 1 6 6 1 0 0 0 0 0 0 0 0 3080-1 frdr 6 1 4 4 0 0 0 0 0 0 0 0 0 90802 10 1 6 6 1 0 0 0 0 0 0 0 0 2050-2 2 2 1 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 216-No184696A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 10:08:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Slimline A/C Calculation Date/Time: 09:58, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3USEER14.xml CF1 R-PI2F-NC13-01 Page 7 of 12 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (Rooffile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic floor - Cavity: - no insulation - Sheathinglnsulation - no sheathing/insul. - GarageRoof Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity. R 21 Sheathing/Insulation: - no sheathing/insul. - R-21 Wall Exterior. Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 Exterior Finish: Wood Siding/sheathing/decking Attic Floor: - no attic floor - Cavity: R 38 R-38 Roof Attic RB Ceilings (below attic) Wood rF amed Ceiling 2 @;24 n; O R 38,1 R� Sheathinglnsulation - no sheathing/insul. - • Inside Finish: Gypsum Board I :[Inside Finish: Gypsum Board ['--� Sheathing/Insulation: - no sheathing/insul. - Cavity: R 21 Sheathing/Insulation: - no sheathing/insul. - R-21 Wall'! Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 Other Side Finish: Gypsum Board Floor Surface: Carpeted Concrete Fill: - no concrete fill - Floor Deck: Wood Siding/sheathing/decking Cavity: R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Floor No Crawlspace Exterior Floors Wood Framed Floor 2x6 @ 16 in. O.C. R 19 Exterior Finish: - select finish - Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: - no insulation (vertical) - - no insulation Sheathing/Insulation: - no sheathing/insul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. (vertical) - Exterior Finish: 3 Coat Stucco Registration Number: 216-N0184696A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 10:08:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Slimline A/C Calculation Date/Time: 09:58, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3USEER14.xmi CF1 R-PRP-NCB-01 Page 8 of 12 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab2 Main 2246 255 None 0.8 No Slab Casita 282 40 None 0.8 No Slab -on -Grade Garage 519 122 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED NOT REQUIRED --- WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 .. l� FStandard. r= r r� ` 1 0.0% WATER HEATERS ' ,l \\ \�_y' ( 01 02 21 203 04 05 06 07 08 Name v Heater Element Type ' I 1L_ ' % `} Tank Type Tank Volumes (gal) ' Energy Factor ors"— Efficiency ' ' Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0 0.95 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a n/a Registration Number: 216-N0184696A-000000000-0000 Registration Date/Time: 2016-05-1810:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 10:08:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Slimline A/C Calculation Date/Time: 09:58, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3USEER14.xml CFI R-FRF-NCS-01 Page 9of12 HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC SystemM1 Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 2246 HVAC SystemC2 Heat Pump Heating and Cooling Heat Pump System 2 No Heat Pump System No HVAC HVAC 675 System 2 SystemC2-dist SystemC2-fan HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - HEATING SYSTEMS: Heat Pumps 01 02 03 04 _ _ 05 06 07 { Heatm,g' ` 7} Cooling SEER EER Name Type Effi iency Cap I I qapf 7 _ Heat Pump System 2 DuctlessHeatPump;'-Heating side ofm ductless mini -split heat pump ' I E � HSPF -} �35000, f � �150� ID 16 13 HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 12 14 Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Not Required Required Required Heat Pump System 2-hers-cool Not Required Not Required Required Required Registration Number: 216-No184696A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 10:08:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Slimline A/C Calculation Date/Time: 09:58, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3USEER14.xml CF1 R-PRP-NCB-01 Page 10 of 12 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in unconditioned Specified Lower 8 Attic Attic None Air Distribution attic Leakage Target System 1-hers-dist HVAC HVAC SystemC2-dist Ducts located in unconditioned Sealed and tested 8 Attic Attic None System C2-dist-hers- attic dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required HVAC SystemC2-dist-hers-dist Not Required Not Required Not Required Not Required HVAC -FAN SYSTEMS .-� II fr 01 r`�� i 102f �ii� 11 �� U3 04 Name ~��1 �^ '` �� Type'`—`=� L—= u u u �� Ll Far;Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fang' � � ,V I L) -0:58 � Required HVAC SystemC2-fan Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 HVAC SystemC2-fan-hers-fan Not Required IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 59 Exhaust 0 Required Registration Number: 216-No184696A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 10:08:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R-PRF-NCS-01 Project Name: Plan 3 w/Slimline A/C Calculation Date/Time: 09:58, Wed, May 18, 2016 Page 11 of 12 Calculation Description: Title 24 Analysis Input File Name: 14023P3USEER14.xml 'OOLING VENTILATION NONE -�N C (C' RTS (01 Registration Number: 216-N0184696A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-18 10:08:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 w/Slimline A/C Calculation DatefTime: 09:58, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023P3USEER14.xmi CFI R-PRF-NCB-01 Page 12 of 12 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ��" �✓�acsrm Rudy Sains Company: Signature Date: Heritage Energy Group 2016-05-18 10:15:30 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949-584-1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to:the enforcement.agency.for approval with this building permit application. Responsible Designer Name: �.,��� ! ResponsibleDesigner Sigriatujrje: �a�Pi�a�v In� Dave Warren �,-'t1,{ If Company: Date Signed: 0 6-05 18 10:22:54� California West Communities Address: License: 5927 Priestly Drive, Suite 103 N/A City/State/Zip: Phone: Carlsbad, CA 92008 760-918-2824 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-N0184696A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 10:08:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Date/Time: 01:33, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023p4U.xml CFI R-PRF-NC6=01 Page 1 of 11 GENERAL INFORMATION 01 Project Name Plan 4 02 Calculation Description Title 24 Analysis 03 Project Location The Estates 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-2 (595c) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 3446 15 Number of Zones 1 16 Slab Area (FT2) 2733 17 Number of Stories 2 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 Glazing Percentage (%) 27.7% Detailed help on using the CF-1111 Certificate oflComplianceAl Itrs avallableviathe Internet by either,-.� ' r scanning eQR r to<�\\-�U'\'cn U htp://www.title24pnergycode.org/t24help/cfl r.aspx In iL .3 II" R 0 V! D E R COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-N0184863A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 01:44:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Date/Time: 01:33, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023p4U.xml CFI R-P'RF-NCB-01 Page 2of11 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 2.94 3.17 -0.23 -7.8% Space Cooling 108.51 108.51 0.00 0.0% IAQ Ventilation 0.93 0.93 0.00 0.0% Water Heating 8.20 4.23 3.97 48.4% PV Credit ---- 0.00 0.00 ---- North Facing -TOTAL 120.58 116.84 3.74 3.1% Space Heating 2.94 3.66 -0.72 -24.5% Space Cooling 108.51 106.64 1.87 1.7% IAQ Ventilation 0.93 0.93 0.00 0.0% Water Heating 8.20 4.23 3.97 48.4% PV Credit ---- 0.00 0.00 ---- East Facing - TOTAL 120.58 115.46 5.12 4.2% Space Heating 2.94 3.51 -0.57 -19.4% Space Cooling IAQ Ventilation 0851 .93C (�'o'2o 104:914 ri3.57 0.93 E 0.00 3.3% 0.0% Water Heating :8.3" 4.23 /7 3:97 48.4% PV Credit H E R S P R0.00� i/ # D E R 0.00 ---o South Facing - TOTAL 120.58 113.61 i J� 6.97 5.8 /o Space Heating 2.94 2.78 0.16 5.4% Space Cooling 108.51 105.42 3.09 2.8% IAQ Ventilation 0.93 0.93 0.00 0.0% Water Heating 8.20 4.23 3.97 48.4% PV Credit ---- 0.00 0.00 --- West Facing - TOTAL 120.58 113.36 7.22 6.0% Registration Number: 216-N0184863A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 01:44:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-NCB-91 Project Name: Plan 4 Calculation Date/Time: 01:33, Wed, May 18, 2016 Page 3 of 11 Calculation Description: Title 24 Analysis Input File Name: 14023p4U.xml REQUIRED SPECIAL FEATURES fhe following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. Window overhangs and/or fins BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 4 3446 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 living Conditioned HVAC System 3446 10.1 DHW Sys 1 no C CERTSv nco HERS PROVIDE R Registration Number: 216-N0184863A-000000000-0000 Registration Date/Time: 2016-05-1810:22:54 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-18 01:44:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Date/Time: 01:33, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023p4U.xml CF1 R-PRP-NCB-01 Page 4 of 11 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft2) Tilt(deg) Front Wall living R-19 Wall 0 Front 399 72 90 Left Wall living R-19 Wall 90 Left 895 129 90 Rear Wall living R-19 Wall 180 Back 653 314 90 Right Wall living R-19 Wall 270 Right 1150 222 90 garage wall living R-19 Wall 0 Front 200 0 90 garage wall2 living R-19 Wall 90 Left 100 0 90 Front Wall 2 living R-19 Wall 0 Front 373 92 90 Left Wall 2 living R-19 Wall 90 Left 337 0 90 Rear Wall 2 living R-19 Wall 180 Back 373 59 90 Right Wall 2 living R-19 Wall 270 Right 337 68 90 Roof 'living R-38 Roof Attic RB 2051 Roof 2 living R-38 Roof Attic RB 713 Raised Floor living �� —� R19jFloor'No Crawlspace� = — -- --., 315 garage wall Right r Garage !,Garage Exit Wall =1 ~270 Rights 283 0 90 Garage wall front Garage �" i u Garage EztWall 0' i t L Fronf a 323 0 90 garage wall Left GarajeA K'Ga'rage EA Wall K (, 196 1 1 .) {Left K 283 0 90 Exterior Wall Garage Garage Ext Wall 0 Front 1 0 90 Roof 3 Garage R-0 Roof Attic 519 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 3 0.1 0.85 Yes No Registration Number: 216-N0184863A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 01:44:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Date/Time: 01:33, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023p4U.xml CF1 R-PRIG-NC113-01 Page 5 of 11 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height (ft) Width(ft ) Multiplie r Area (ft2) U- factor SHG C Exterior Shading 9080 ddr Window Front Wall (Front-0) ---- ---- 1 72.0 0.27 0.23 3060-2 Window Left Wall (Left-90) 5.0 5.0 1.44 36.0 0.29 0.20 3020-2 Window Left Wall (Left-90) 2.0 6.0 1 12.0 0.27 0.23 4050 Window Left Wall (Left-90) ---- ---- 1 20.0 0.29 0.20 3020-2 2 Window Left Wall (Left-90) 2.0 6.0 1 12.0 0.27 0.23 4020 Window Left Wall (Left-90) 2.0 4.0 1 8.0 0.27 0.23 2040-2 Window Left Wall (Left-90) ---- ---- 1 16.0 0.29 0.20 5050 Window Left Wall (Left-90) 5.0 5.0 1 25.0 0.29 0.20 16080 ddr Window Rear Wall (Back-180) 8.0 16.0 1 128.0 0.28 0.21 9080 ddr 2 Window Rear Wall (Back-180) ---- ---- 1 72.0 0.28 0.21 Transom Window Rear Wall (Back-180) 2.0 9.0 1 18.0 0.27 0.23 12080 Window - Rear Wall (Back-180) --- ---- 1 96.0 0.28 0.21 4060-2 Window Right Wall (Right-270) {� r( � t - i r- 1 48.0 0.29 0.20 4030-2 Window \' _RightWall (Right-270)(� �� rf �, �� '�,1�,� 24.0 0.27 0.23 12080 ddr Window! ; Right Walll(Right`270) 8.0 ,R 12.0, 1 96.0 0.28 0.21 2040-2 2 Window Right Wall`(Right=270) `` - ' -` - r 1 16.0 0.29 0.20 3050-2 Window Right Wall (Right-270) ---- -- 1 30.0 0.29 0.20 2020-2 Window Right Wall (Right-270) ---- ---- 1 8.0 0.27 0.23 3050-2 2 Window Front Wall 2 (Front-0) 5.0 6.0 1 30.0 0.29 0.20 2040 Window Front Wall 2 (Front-0) 4.0 2.0 1 8.0 0.27 0.23 3050-2 3 Window Front Wall 2 (Front-0) 5.0 6.0 1 30.0 0.29 0.20 3080 FRDR Window Front Wall 2 (Front-0) 8.0 3.0 1 24.0 0.35 0.25 2040-3 Window Rear Wall 2 (Back-180) ---- ---- 1 24.0 0.27 0.23 3050 Window Rear Wall 2 (Back-180) ---- ---- 1 15.0 0.29 0.20 Transom 2 Window Rear Wall 2 (Back-180) ---- ---- 1 20.0 0.27 0.23 3050-2 4 Window Right Wall 2 (Right-270) ---- ---- 1 30.0 0.27 0.23 3030-2 Window Right Wall 2 (Right-270) ---- ---- 1 1 18.0 0.27 0.23 2050-2 Window Right Wall 2 (Right-270) -- ---- 1 1 20.0 0.29 0.20 Registration Number: 216-N0184863A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 01:44:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Description: Title 24 Analysis Calculation Date/Time: 01:33, Wed, May 18, 2016 Input File Name: 14023p4U.xml CFI R-PRF-NCB-01 Page 6 of 11 DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door Front Wall 28.0 0.50 Door 16080 Garage wall front 128.0 1.00 Door 6080 garage wall Left 48.0 1.00 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up 3060-2 0 0 0 0 0 0 0 0 0 0 0 0 0 3020-2 2 1 2 2 0 0 0 0 0 0 0 0 0 3020-2 2 2 1 2 2 0 0 0 0 0 0 0 0 0 4020 \ 2 1 -- 2 n 2+ y 0 ,-,-, ____,0 �� On 0 0 0 0 0 0 5050 0 r 0 �` u� L)) I I 0 011 0� 0 0 0 0 0 16080ddr 14.�.� '�1 1.�1-10C) 111110.— 1101 V II 01J, r, Oil 11 11 0 0 0 0 0 0 Transom ' 2 1 1 12 9-7 r7b 2 C.- r n je 0 *4 AV 1 0-.y r-- 0r-10 0 0 0 0 0 12080 ddr 2 9' ` '2 `"` ' `2 """ ' 0 '-" b - ' 0"'� "— cc ' 0 0 0 0 0 3050-2 2 2 1 2 2 0 0 0 0 0 0 0 0 0 2040 2 1 2 2 0 0 0 0 0 0 0 0 0 3050-2 3 8 1 4 4 0 0 0 0 0 0 0 0 0 3080 FRDR 8 1 4 4 0 0 0 0 0 0 0 0 0 Registration Number: 216-N0184863A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 01:44:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Date/Time: 01:33, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023p4U.xml CFI R-PRF-NCB-01 Page 7 of 11 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity. - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic floor - Cavity. - no insulation - Sheathinglnsulation - no sheathing/insul. - R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Attic Floor. - no attic floor - Cavity. R 38 R-38 Roof Attic RB 4' Ceilings (below attic) - Wood'Framed Ceiling 2x4'@ 24 in . O.C.— R 38 Sheathinglnsulation - no sheathing/insul. - Inside Finish: Gypsum Board t l Floor Surface: Carpeted :LConcrete Fill: - no concrete fill - HERS R C U V I E)E• Floor Deck. Wood Siding/sheathing/decking R Cavity: R 19 Sheathing/Insulation: - no sheathing/insul. - R-19 Floor No Crawlspace Exterior Floors Wood Framed Floor 2x6 @ 16 in. O.C. R 19 Exterior Finish: - select finish - Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: - no insulation (vertical) - - no insulation Sheathing/Insulation: - no sheathing/insul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. (vertical) - Exterior Finish: 3 Coat Stucco SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab living 2733 288 None 0.8 No Slab 2 Garage 512 88 None 0 No Registration Number: 216-N0184863A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 01:44:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Date/Time: 01:33, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023p4U.xml CF1 R-PRF-NCB-G'1 Page 8 of 11 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Instal lation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED NOT REQUIRED --- WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Standard 1 0.0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0 0.95 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 n 03 ( �f 05 06 07 Name Pipe Insulation U '\� t U PParallel•Pipingd r 1 Z1 U Compact Distributiont ! 11 ` U Point of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a - n/a - n/a - _ ii/a n/a HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC System1 Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 3446 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 216-N0184863A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 01:44:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Date/Time: 01:33, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023p4U.xml CF1 R-PRF-NCB-61 Page 9 of 11 HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 12 14 Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Not Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type, Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in unconditioned Specified Lower / 6��� c � Attic c Attic None Air Distribution System 1-hers-dist attic Target !! i% Jl HVAC DISTRIBUTION - HERS VERIFICATION' i' �' " ' ` ` `' �' " 01 02 ir-- % It i 01"' 1`104 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required T77Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 Registration Number: 216-N0184863A-000000000-0000 Registration Date/Time: 2016-05-1810:22:54 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-18 01:44:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Date/Time: 01:33, Wed, May 18, 2016 Calculation Description: Title 24 Analysis Input File Name: 14023p4U.xml CF1 R-VRF-NCB-01 Page 10 of 11 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 72 Exhaust 0 Required -OOLING VENTILATION NONE rUnu L 23�, L It HER 5 PROVIDER Registration Number: 216-N0184863A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c Report Generated at: 2016-05-18 01:44:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Description: Title 24 Analysis Calculation Date/Time: 01:33, Wed, May 18, 2016 Input File Name: 14023p4U.xml CF1 R-PRE-NCB-01 Page 11 of 11 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Rudy Sains Company: Signature Date: Heritage Energy Group 2016-05-18 10:21:58 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949-584-1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to.,the enforcement.agency,for approval with this building permit application. Responsible Designer Name: { ResponjsiibleDesigner Sigri6ture: �adPi�ir�vu�v T C Dave Warren C`�..1 t� ! t '� ! I n 1 t t� Company: Date Signed: 2016-05 18 110: 2:54� California West Communities Address: License: 5927 Priestly Drive, Suite 103 N/A City/State/Zip: Phone: Carlsbad, CA 92008 760-918-2824 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-N0184863A-000000000-0000 Registration Date/Time: 2016-05-18 10:22:54 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595c CaICERTS inc. Report Generated at: 2016-05-18 01:44:02 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 1 Date 5/18/2016 System Name HVAC SystemM Floor Area 2,224 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,507 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 94,000 29,842 2,682 596 29,094 Total Output (Btuh) 94,000 0 Output Btuh/s ft 42.3 2,037 1,678 Cooling System 0 0 Output per System 46,300 0 0 0 0 Total Output Btuh) 46,300 0 2,037 1 33,915 2,682 0 Total Output (Tons) 3.9 1,678 Total Output (Btuh/s ft) 20.8 Total Output s ft/Ton 576.4 32,450 Air System CFM perSystem 1,375 HVAC EQUIPMENT SELECTION Airflow cfm 1,375 95-14-12 38,399 1,126 94,000 Airflow (cfm/s ft) 0.62 Airflow (cfm/Ton) 356.4 Outside Air (%) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 38,399 1,126 94,000 Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 67 OF 67 OF 115 OF Outside Air 0 cfm Supply Fan Heating Coil 1,375 cfm 67 OF 114 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF 76/62OF 76/63OF 55/54OF Outside Air 0 cfm Supply Fan Cooling Coil 56 / 54 OF 1,375 cfm 48.3 % ROOM 76/62OF 75/62OF EnergyPro 6.2 by EnergySoft User Number: 7244 RunCode: 2016-05-18T10:42:36 ID: 14023 Page 1 of 2 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 1 Date 5/18/2016 System Name HVAC SystemC Floor Area 304 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 241 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 49,000 5,122 367 135 6,736 Total Output (Btuh) 49,000 0 Output Btuh/s ft 161.2 0 0 Cooling System 0 0 Output per System 0 0 0 0 0 Total Output (Btuh) 0 0 367 0 Total Output (Tons) 0.0 0 0 Total Output (Btuh/s ft) 0.0 Total Output s ft/Ton 0.0 5,122 6,736 Air System CFM per System 775 HVAC EQUIPMENT SELECTION Airflow cfm 775 Carrier 58MTB0080-16 (Low Heat) 0 0 49,000 Airflow (cfm/s ft) 2.55 Airflow (cfm/Ton) 0.0 Outside Air (%) 0-0 % Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 0 0 49,000 Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 68 OF 68 OF 115 OF Outside Air 11110 0---* 1 0. 3 0 cfm Supply Fan Heating Coil 775 cfm 68 OF 115 °F ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak) 112/78OF 75/62OF 75/62OF 55/54OF Outside Air 0 cfm Supply Fan Cooling Coil 55 / 54 OF 775 cfm 46.7 % ROOM 75/62OF 75/62OF EnergyPro 6.2 by EnergySoft User Number: 7244 RunCode: 2016-05-18T10:42:36 ID: 14023 Page 2 of 2 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 1 Date 5/18/2016 System Name HVAC SystemM Floor Area 2,516 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,555 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 94,000 30,735 3,034 599 29,242 Total Output (Btuh) 94,000 0 Output Btuh/s ft 37.4 2,097 1,687 Cooling System 0 0 Output perSystem 46,300 0 0 0 0 Total Output (Btuh) 46,300 0 3,034 0 Total Output (Tons) 3.9 2,097 1,687 Total Output Btuh/s ft) 18.4 Total Output s ft/Ton 652.1 1 34,929 32,615 Air System CFM per System 1,375 HVAC EQUIPMENT SELECTION Airflow cfm 1,375 95-14-12 38,279 1,310 94,000 Airflow (cfm/s ft) 0.55 Airflow (cfm/Ton) 356.4 94,000 Jan 1 AM Outside Air (%) 0•0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 38,279 1,310 Outside Air cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 67 OF 67 OF 115 OF Outside Air 0 cfm Supply Fan He Coil 1,375 cfm 67 OF 114 °F ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak) 112/78OF 76/63OF 76/63OF 55/54OF Outside Air 0 cfm Supply Fan Cooling Coil 56 / 54 OF 1,375 cfm 48.6 % ROOM M 76 / 63 OF 75 / 62 OF EnergyPro 6.2 by EnergySoft User Number: 7244 RunCode: 2016-05-18T10:43:40 ID: 14023 Page 1 of 2 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 1 Date 5/18/2016 System Name HVAC SystemC Floor Area 272 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 193 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 49,000 4,117 328 120 6,017 Total Output Btuh) 49,000 0 Output Btuh/s ft 180.1 0 0 Cooling System 0 0 Output perSystem 0 0 0 0 0 Total Output Btuh) 0 0 3281 0 Total Output (Tons) 0.0 0 0 Total Output (Btuh/s ft) 0.0 Total Output s ft/Ton 0.0 4,117 1 6,017 Air System CFM per System 775 HVAC EQUIPMENT SELECTION Airflow cfm 775 Carrier 58MTB0080-16 (Low Heat) 0 0 49,000 Airflow cfm/s ft) 2.85 Airflow (cfm/Ton) 0.0 Outside Air (%) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 0 0 49,000 Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 68 OF 68 OF 115 OF Outside Air 0 cfm Supply Fan Heating Coil 775 cfm 68 OF 4 J-1 --- 1A 115 OF Room 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF 75/62OF 75/62OF 55/54OF ism C Outside Air 0 cfm Supply Fan Cooling Coil 55 / 54 OF 775 cfm 46.6 % ROOM 75/62OF 75/62OF EnergyPro 6.2 by EnergySoft User Number. 7244 RunCode: 2016-05-18T10:43:40 ID: 14023 Page 2 of 2 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 2 Date 5/18/2016 System Name HVAC System Floor Area 2,760 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,875 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 94,000 36,503 4,017 690 33,563 Total Output (Btuh) 94,000 0 Out ut Btuh/s ft 34.1 2,491 1,936 Cooling System 0 0 Output per System 46,300 0 0 0 0 Total Output (Btuh) 46,300 0 4,017 0 Total Output (Tons) 3.9 2,491 1,936 Total Output (Btuh/s ft) 16.8 Total Output s ft/Ton 715.3 1 41,486 37,435 Air System CFM perSystem 1,375 HVAC EQUIPMENT SELECTION Airflow cfm 1,375 FAU 95% 14SEER 11.7 EER 38,078 1,719 94,000 Airflow (cfm/s ft) 0.50 Airflow (cfm/Ton) 356.4 Outside Air (%) 0•0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 38,078 1,719 94,000 F Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 67 OF 67 OF 115 OF Outside Air 0 cfm Supply Fan Heating Coil 1,375 cfm 67 OF 114 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF 77/63OF 77/63OF 55/54OF Outside Air � 0 cfm Supply Fan Cooling Coil 57 / 55 OF 1,375 cfm 49.4 % ROOM 77/63OF 75/62OF EnergyPro 6.2 by EnergySoft User Number: 7244 RunCode: 2016-05-18T10:44:46 ID: 14023 Page 1 of 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 2 w/Bedroom 4 Date 5/18/2016 System Name HVAC System Floor Area 2,766 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,843 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 94,000 35,939 4,026 683 33,216 Total Output (Btuh) 94,000 0 Output Btuh/s ft 34.0 2,453 1,916 Cooling System 0 0 Output perSystem 46,300 0 0 0 0 Total Output (Btuh) 46,300 0 4,026 0 Total Output (Tons) 3.9 2,453 1,916 Total Output (Btuh/s ft) 16.7 Total Output (s ft/Ton) 716.9 1 40,845 37,048 Air System CFM perSystem 1,375 HVAC EQUIPMENT SELECTION Airflow cfm 1,375 FAU 95% 14SEER 11.7 EER 38,052 1,742 94,000 Airflow (cfm/s ft) 0.50 Airflow (cfm/Ton) 356.4 Outside Air (%) 0•0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 38,052 1,742 94,000 Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 67 OF 67 OF 115 OF Outside Air 0 cfm Supply Fan Heating Coil 1,375 cfm 67 OF 114 OF *A ROOM 0 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF 77/63OF 77/63OF 55/54OF c Outside Air c 0 cfm Supply Fan Cooling Coil 1,375 cfm 77 163 OF rn 57 / 55 OF 49.4 % ROOM 75 / 62 OF EnergyPro 6.2 by EnergySoft User Number: 7244 RunCode: 2016-05-18T10:45:25 ID: 14023 Page 1 of 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 3 Date 5/18/2016 System Name HVAC SystemM Floor Area 2,246 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,511 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 30,638 3,286 783 30,203 Total Output (Btuh) 89,000 0 Output Btuh/s ft) 39.6 1,696 1,340 Cooling System 0 0 Output per System 46,500 0 0 0 0 Total Output (Btuh) 46,500 0 3,286 0 Total Output (Tons) 3•9 1,696 1,340 Total Output (Btuh/s ft) 20.7 Total Output s ft/Ton) 579.6 1 34,029 132,884 Air System CFM perSystem 1,680 HVAC EQUIPMENT SELECTION Airflow cfm 1,680 15/12/80% 31,581 8,038 89,000 Airflow (cfm/s ft) 0.75 Airflow (cfm/Ton) 433.5 Outside Air (%) 0•0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 31,581 8,038 89,000 Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 67 OF 67 OF 105 OF Outside Air 0 cfm Supply Fan Heating Coil 1,680 cfm 67 OF 4 Ar- 4 J 104 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF 76/62OF 76/62OF 55/54OF Outside Air 0 cfm Supply Fan Cooling Coil 56 / 54 OF 1,680 cfm 48.4 % ROOM- M 76/62OF 75/62OF EnergyPro 6.2 by EnergySoft User Number: 7244 RunCode: 2016-05-18T10:46:12 ID: 14023 Page 1 of 2 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 3 Date 5/18/2016 System Name HVAC SystemC Floor Area 675 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 589 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 35,000 12,536 988 261 13,053 Total Output (Btuh) 35,000 0 Output Btuh/s ft 51.9 0 0 Cooling System 0 0 Output per System 46,300 0 0 0 0 Total Output (Btuh) 46,300 0 988 0 Total Output (Tons) 3•9 0 0 Total Output Btuh/s ft 68.6 Total Output s ft/Ton 174.9 1 12,536 13,053 Air System CFM perSystem 1,375 HVAC EQUIPMENT SELECTION Airflow cfm 1,375 hp16-13 37,980 1,028 21,860 Airflow (cfm/s ft) 2.04 Airflow (cfm/Ton) 356.4 Outside Air (%) 0-0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 37,980 1,028 21,860 Jan 1 AM Outside Air cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 68 OF 68 OF 115 OF Outside Air 0 cfm Supply Fan Heating Coil 1,375 cfm 68 OF 4 J 115 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak) 112/78OF 75/62OF 75/62OF 55/54OF Outside Air 0 cfm Supply Fan Cooling Coil 55 / 54 OF 1,375 cfm 47.0 % ROOM 75 / 62 OF 75 / 62 OF EnergyPro 6.2 by EnergySoft User Number: 7244 RunCode: 2016-05-18T10:46:12 ID: 14023 Page 2 of 2 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 3 w/Bedroom 3 Date 5/18/2016 System Name HVAC SystemM Floor Area 2,484 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,565 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 31,685 3,634 786 30,316 Total Output (Btuh) 89,000 0 Output Btuh/s ft 35.8 1,754 1,346 Cooling System 0 0 Output perSystem 46,500 0 0 0 0 Total Output (Btuh) 46,500 0 3,634 0 Total Output (Tons) 3•9 1,754 1,346 Total Output Btuh/sgft) 18.7 Total Output s ft/Ton 641.0 35,192 1 33,007 Air System CFM perSystem 1,680 HVAC EQUIPMENT SELECTION Airflow cfm 1,680 14/12/80% 31,510 8,162 89,000 Airflow (cfm/s ft) 0.68 Airflow (cfm/Ton) 433.5 Outside Air (%) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 31,510 8,162 89,000 Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 67 OF 67 OF 105 OF Outside Air 0 cfm Supply Fan Heating Coil 1,680 cfm 67 OF 4 On �1 4 104 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF 76/62OF 76/62OF 55/54OF Outside Air c 0 cfm Supply Fan Cooling Coil 56 / 54 OF 1,680 cfm 48.6 % ROOM 76/62OF 75/62OF EnergyPro 6.2 by EnergySoft User Number: 7244 RunCode: 2016-05-18T10:47:17 ID: 14023 Page 1 of 2 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 3 w/Bedroom 3 Date 5/18/2016 System Name HVAC SystemC Floor Area 675 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 550 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 35,000 11,707 988 249 12,430 Total Output (Btuh) 35,000 0 Output Btuh/s ft 51.9 0 0 Cooling System 0 0 Output perSystem 46,300 0 0 0 0 Total Output Btuh) 46,300 0 988 0 Total Output (Tons) 3.9 0 0 Total Output (Btuh/s ft) 68.6 Total Output s ft/Ton 174.9 1 11,707 12,430 Air System CFM perSystem 1,375 HVAC EQUIPMENT SELECTION Airflow cfm 1,375 hp16-13 37,980 1,028 21,860 Airflow (cfm/s ft) 2.04 Airflow (cfm/Ton) 356.4 Outside Air (%) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 37,980 1,0281 21,860 Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 68 OF 68 OF 115 OF Outside Air 0 cfm Supply Fan Heating Coil 1,375 cfm 68 OF 115 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF 75/62OF 75/62OF 55/54OF Outside Air c 0 cfm Supply Fan Cooling Coil 55 / 54 OF 1,375 cfm p - 47.0 % ROOM 75/62OF 75/62OF EnergyPro 6.2 by EnergySoft User Number: 7244 RunCode: 2016-05-18T10:47:17 ID: 14023 Page 2 of 2 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 3 w/Slimline A/C Date 5/18/2016 System Name HVAC SystemM Floor Area 2,246 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,474 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 30,128 3,286 762 29,499 Total Output (Btuh) 89,000 0 Output Btuh/s ft 39.6 1,420 1,126 Cooling System 0 0 Output per System 46,500 0 0 0 0 Total Output (Btuh) 46,500 0 3,286 0 Total Output (Tons) 3.9 1,420 1,126 Total Output (Btuh/s ft) 20.7 Total Output s ft/Ton 579.6 32,967 31,751 Air System CFM per System 1,680 HVAC EQUIPMENT SELECTION Airflow cfm 1,680 14/12/80% 31,397 8,196 89,000 Airflow (cfm/s ft) 0.75 Airflow cfm/Ton) 433.5 Outside Air (%) Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 31,397 8,196 89,000 Outside Air (cfm/s ft mo Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 67 OF 67 OF 105 OF Outside Air 11N. L= 0 cfm Supply Fan Heating Coil 1,680 cfm 67 OF 4 104 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF 76/62OF 76162OF 55/54OF Do A Outside Air 0 cfm Supply Fan Cooling Coil 56 / 54 OF 1,680 cfm 48.4 % ROOM E 76 / 62 OF 75 ! 62 OF ri EnergyPm 6.2 by EnergySoft User Number: 7244 RunCode: 2016-05-18T10:48:03 ID: 14023 Page 1 of 2 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 3 w/Slimline A/C Date 5/18/2016 System Name HVAC SystemC Floor Area 675 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 538 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 35,000 11,452 988 221 11,029 Total Output Btuh) 35,000 0 Output Btuh/s ft) 51.9 0 0 Cooling System 0 0 Output perSystem 46,300 0 0 0 0 Total Output (Btuh) 46,300 0 988 0 Total Output (Tons) 3.9 0 0 Total Output (Btuh/s ft) 68.6 Total Output s ft/Ton 174.9 11,452 11,029 Air System CFM perSystem 1,375 HVAC EQUIPMENT SELECTION Airflow cfm 1,375 hp16-13 37,980 1,028 21,860 Airflow (cfm/s ft) 2.04 Airflow (cfm/Ton) 356.4 Outside Air (% 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 37,980 1,028 21,860 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 68 OF 68 OF 115 OF Outside Air 0. 0 cfm Supply Fan Heating Coil 1,375 cfm 68 OF 4 115 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak 112/78OF 75/62OF 75/62OF 55/54OF C Outside Air 0 cfm Supply Fan Cooling Coil 55 / 54 OF 1,375 cfm 47.0 % ROOM 75/62OF 75/62OF EnergyPro 6.2 by EnergySoft User Number: 7244 RunCode: 2016-05-18T10:48:03 ID: 14023 Page 2 of 2 A k HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 4 Date 5/18/2016 System Name HVAC System Floor Area 3,446 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total ROOM Loads 2,358 Return Vented Lighting Return Air Ducts Return Fan Ventilation F 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 46,917 4,986 1,177 45,297 Total Output (Btuh) 89,000 0 Output Btuh/s ft 25.8 2,597 2,010 Cooling System 0 0 Output per System 46,500 0 0 0 0 Total Output (Btuh) 46,500 0 4,986 0 Total Output (Tons) 3.9 2,597 2,010 Total Output (Btuh/s ft) 13.5 Total Output s ft/Ton 889.3 1 52,110 149,318 Air System CFM per System 1,680 HVAC EQUIPMENT SELECTION Airflow cfm 1,680 14/12/80% 31,956 7,823 89,000 Airflow (cfm/s ft) 0.49 Airflow (cfm/Ton) 433.5 Outside Air (%) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 31,956 7,823 89,000 Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 67 OF 67 OF 105 OF 1-0 1 1 11 Outside Air 0 cfm Supply Fan Heating Coil 1,680 cfm 67 OF 104 OF ROOM ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF 76/63OF 76/63OF 55/54OF Outside Air Ar 0 cfm Supply Fan Cooling Coil 56 / 54 OF 1,680 cfm 49.0 % ROOM 76/63'IF 75/62OF EnergyPro 6.2 by EnergySoft User Number: 7244 RunCode: 2016-05-18T10:49:29 ID: 14023 Page 1 of 1