Loading...
BSOL2019-0026Date: i CALLE TAMPICO D -!n' VOICE (760) 777-7125 .(UINTA, CALIFORNIA 92253 DESIGN &DEVELOPMENT DEPARTMENT FAX (760) 777-7011 INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 2/26/2020 Permit Type/Subtype: SOLAR/RESIDENTIAL LESS THAN 10KW Owner: Application Number: BSOL2019-0026 HEFTI DENISE LEBRE Property Address: 52273 AVENIDA MADERO 52273 AVENIDA MADERO APN: 773241019 LA QUINTA, CA 92253 Application Description: LEBRE / 5.795 kW PV SYSTEM - (19) 305W PANELS/(1) INVERTER Property Zoning: Application Valuation: $19,000.00 Applicant: Contractor: FREEDOM FOREVER LLC - CAMILLE ABRAHAM � FREEDOM FOREVER LLC 43445 BUSINESS PARK DR STE 110 43445 BUSINESS PARK DR STE 110 TEMECULA, CA 92590 FEB 2 6 2020 TEMECULA, CA 92590 CITY OF LAQUINTA (951)319-4975 DESIGN & DEVELOPMENT DEPARTMENT Llc. No.: 1029644 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B, C10, C46, C39 License No.: 1029644 Date: Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, Improve, demolish, or repair any structure, prior to Its Issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Buslnessand Professions Cade) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permlt Subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the Improvements are not intended or offered for sale. If, however, the building or improvement fs sold APPLICANT ACKNOWLEDGEMENT within one year Of completion, the owner-but(der will have the burden of proving that IMPORTANT: Application is hereby made to the Building Official for a permit subject to he or she did not build or improve For the purpose of sale.). the conditions and restrictions set forth on this application. () I, as owner of the property, am exclusively contracting with licensed contractors 1. Each person upon whose behalf this application is made, each person at whose to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' request and for whose benefit work is performed under or pursuant to any permit State License Law does not apply to an owner of property who builds or improves issued as a result of this application , the owner, and the applicant, each agrees to, and thereon, and who contracts for the projects with a contractor(s) licensed pursuant to shall defend, indemnify and hold harmless the City of La Quanta, its officers, agents, and the Contractors' State License Law.). employees for any act of omission related to the work being performed under or (_) I am exempt under Sec. B.&P.C. for this reason following issuance of this permlt. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance oft ofk for which this permit is issued. ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: REDWOOD,FIRE AND CMUA INSURANCE CQ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. ✓?ate: d d I � Applicant: 1114~ WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. Date:o D OL ignature (Applicant or Agent) Date: 2/26/2020 Application Number: BSOL2019-0026 Property Address: 52273 AVENIDA MADERO APN: 773241019 Application Description: LEBRE / 5.795 kW PV SYSTEM - (19) 305W PANELS/(1) INVERTER Property Zoning: Application Valuation: $19,000.00 Applicant: FREEDOM FOREVER LLC - CAMILLE ABRAHAM 43445 BUSINESS PARK DR STE 110 TEMECULA, CA 92590 Owner: HEFTI DENISE LEBRE 52273 AVENIDA MADERO LA QUINTA, CA 92253 Contractor: FREEDOM FOREVER LLC 43445 BUSINESS PARK DR STE 110 TEMECULA, CA 92590 (951)319-4975 Llc. No.: 1029644 Detail: 5.795 kW SOLAR ARRAY - (19) 305W CANADIAN SOLAR CS6K-305MS PANELS + SOLAREDGE P320 OPTIMIZERS W/ (1) SOLAREDGE SE5000H-US INVERTER [342SF] 2019 CALIFORNIA ELECTRICAL CODE. DESCRIPTION HOURLY CHARGE - CITY BUILDING STAFF DESCRIPTION HOURLY CHARGE - CITY BUILDING STAFF ACCOUNT CITY 101-0000-42600 0.5 ACCOUNT CITY 101-0000-42600 0.5 Total Paid for BLDG CITY STAFF - PER HOUR: AMOUNT $80.50 AMOUNT $80.50 $161.00 DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT PV SYSTEM LESS THAN 10KW 101-0000-42403 0 $26.83 DESCRIPTION ACCOUNT CITY AMOUNT PV SYSTEM LESS THAN 10KW PC 101-0000-42600 0 $26.83 Total Paid for ELECTRICAL 2019: $53.66 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $101.97 Total Paid for PERMIT ISSUANCE: $101.97 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 PV SYSTEM SUMMARY: 5.795 KW ROOF MOUNT RESIDENTIAL PHOTOVOLTAIC SYSTEM SYSTEM SIZE (DC) STC: 19 X 305= 5795W DC PTC: 19 X 280.30 = 5325.70W DC SYSTEM SIZE (CEC-AC) 19 X 280.30 X 99% = 5272.44W AC MODULES 19 X CANADIAN 305W- CS6K-305MS MODULES INVERTER SOLAR EDGE SE5000H-US [S11] ROOF "S" TILE TILT 18' PITCH AZIMUTH : 180' RAFTER/TRUSS SIZE : 2" X 6" TRUSSES @ 24" O.0 ATTACHMENT TYPE "S" TILE HOOK WITH UNIRAC LIGHT RAIL MAIN SERVICE PANEL EXISTING 125 AMPS MSP WITH 100 AMPS MAIN BREAKER ON CENTER FEED INTERCONNECTION PV BREAKER TIED INTO MSP OCPD RATING : 30 AMPS STRINGING 1 STRING WITH 10 MODULES AND 1 STRING WITH 9 MODULES IN SERIES IN EACH STRING UTILITY IMPERIAL IRRIGATION DISTRICT (IID) TABLE OF CONTENTS PV-1 SITE LOCATION AND HOUSE AERIAL VIEW PV-2 SITE PLAN PV-2A ROOF PLAN WITH MODULES LAYOUT PV-3 ELECTRICAL LINE DIAGRAM PV-4 EXISTING SERVICE PANEL PV-5 ROOF MOUNTING DETAILS, ELEC. CALCULATION & MATERIAL LIST PV-6 LABELS PV-7 OPTIMIZER CHART CLIENT: freedom C190#1f0�9644 FREEDOM FOREVER LLC 43445 Business Park Dr Suite 110, Temecula, CA 92590 Tel: (800) 385-1075 PHOTOVOLTAIC SYSTEM CITY NOTES: THIS PROJECT COMPLIES WITH THE FOLLOWING: 2019 CALIFORNIA BUILDING CODE (CBC) 2019 CALIFORNIA ELECTRICAL CODE (CEC) 2019 CALIFORNIA FIRE CODE (CFC) 2019 CALIFORNIA PLUMBING CODE 2019 CALIFORNIA MECHANICAL CODE 2019 CALIFORNIA ENERGY CODE 2019 CALIFORNIA RESIDENTIAL CODE 2019 CALIFORNIA ADMINISTRATIVE CODE AS ADOPTED BY CITY OF LA QUINTA APN: 773-241-019 MODULES SHALL BE TESTED, LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 1703. THE FIRE CLASSIFICATION SHALL COMPLY WITH TABLE 1505.10F THE CALIFORNIA BUILDING CODE BASED ON THE TYPE OF CONSTRUCTION OF THE BUILDING. CRC SECTION R902.4 SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. RESIDENTIAL BUILDING UNDERGROUND ADDITION OR IMPROVEMENTS SHALL REPLACE NON -COMPLIANT PLUMBING FIXTURES WITH WATER CONSERVING PLUMBING FIXTURES IN ACCORDANCE WITH CGBSC SECTION301.1.1 AND CIVIL CODE 1101.1 AS FOLLOWS: -WATER CLOSETS: 1.6 GPF (GPF= GALLONS PER FLUSH) —FAUCETS (ALL INTERIOR) 2.2 ( GPM = GALLIONS PER MINUTE) --URINALS 1.0 GPF —SHOWER HEADS 2.5 GPM INSTALLATION NOTES: THE PV BREAKER SHALL NOT EXCEED 120% OF THE ALLOWABLE BACK FEED OF THE MAIN SERVICE BUSS RATING. PV WIRE SHALL BE USED ON DC RUNS FOR UNGROUNDED/TRANSFORMERLESS INVERTERS. INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITS ARE ATTACHED TO THE ROOF USING PRESSURE TREATED WOOD IN CASE OF COMPOSITE ROOF OR COUNDUIT HANGERS IN CASE OF CONCRETE ROOF DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE. C I TY 0 LA U, n,'�` N 1FA -� BUILDING DIVI 10I 1 REVIEWED F0F�. �. 7RPV SYSr CODE COMPLIANCE DATE1 _ P'y LEBRE HEFTI, DENISE 52273 AVENIDA MADERO, LA QUINTA, CA 92253 (818)634-3376 SITE LOCATION: `a Calle Sonora HOUSE AERIAL VIEW: REVISIONS: DATE 09/12/2019 DESCRIPTION DATE REVISION ELECTRICAL CORRECTION S 12/9/19 1 DESIGN BY: GREG codes updated to 2019 CEC 2/19/20 2 SOB ID.: I F036219 s Calla Sonora n A , Madero n n 6 SITE LOCATION MODULE LOCATION TITLE: SHEET: SITE LOCATION AND PV_1 HOUSE AERIAL VIEW ROOF AREA: 2815.63 SQ FT 44'-10" FENC,L LIIYL tIV/ IA VMIYMLj1M1V JVJVV- CS6K-305MS MODULES A /1/lr I IKIC r.----r.ry . .- 00 0 "IFVIMPED FOR, SITE PLAN 1 SCALE: 3/32" = 1'-0" IPKW'y k Ko CLIENT: REVISIONS: TITLE: SHEET: C-10#1029644 DATE: 09/12/2019 freedomLEBRE HEFTI, DENISE DESCRIPTION DATE REVISION r� r v F Ti 52273 AVENIDA MADERO, ELECTRICAL 12/9/19 1 DESIGN FREEDOM FOREVER LLC LA QUINTA, CA 92253 CORRECTIONS BY: GREG SITE PLAN PV-2 43445 Business Park Dr Suite 110, Temecula, CA 92590 (818) 634-3376 codes updated to 2019 CEC 2/19/20 2 Tel: (800) 385-1075 JOB ID.: F036219 (N) 19 CANADIAN CS6K-305MS MOI: (D(N) ATTACHMENT POIP 72" O.0 7 r6fdv- ONVOWcg"mKbwNO I CLIENT: .r freedom C-10#1029644 FREEDOM FOREVER LLC 43445 Business Park Dr Suite 110, Temecula, CA 92590 Tel: (800) 385-1075 LEBRE HEFTI, DENISE 52273 AVENIDA MADERO, LA QUINTA, CA 92253 (818) 634-3376 ROOF AREA STATEMENT MODULES ROOF QTY PITCH AZIMUTH ROOF AREA ARRAY AREA 1 19 18° 180' 1298.73 SQ FT 342.55 SQ FT REVISIONS: DESCRIPTION DATE ELECTRICAL 12/9/19 CORRECTION S codes updated to 2019 CEC 2/19/20 NOTE: O EMT CONDUIT SUPPORTED BY PIPE HANGERS 12" TO 18" AWAY FROM ROOF EDGE O ATTACH CLAMP AT 25% FROM EDGE AND 50% FROM CENTER OF MODULES JUNCTION BOX MOUNTED TO THE RAIL LEGEND: Iq CHIMNEY O PIPE VENT UNIT ; JfLOING DIVISION "VEVVED SON I� CODE 3 2" X 6" TRUSSES @ 24" O.0 (TYP.) AIN SERVICE PANEL -ARGER EMT@ ROOF PLAN WITH MODULES LAYOUT 1 SCALE: 1/8" = 1'-0" DATE: 09/12/2019 TITLE: SHEET: REVISION 1 DESIGN ROOF PLAN WITH PV-ZA By. GREG 2 MODULES LAYOUT JOB ID. F036219 16t:' weftup 81 125A Bus.) * (1.2) = 150A Max Rating (120% of Bus) 3V Backfeed (30A) + Main Breaker (100A) = (130A <— 150A) See 705.12 of 2019 CEC STRING-1 10 CANADIAN 305W- CS6K-305MS MODULES SOLAREDGE P320 POWER OPTIMIZERS STRING-2 9 CANADIAN 305W- CS6K-305MS MODULES I I I I I i I SOLAREDGE i P320 POWER OPTIMIZERS ! L_ ... ... --------------- 2 - #10 AWG, PV WIRE 1 - #6 AWG IN FREE AIR OR #8 AWG MUST BE IN EMT CONDUIT General Notes : TOTAL DC kW: 5.795 kW The output of a utility -interactive inverter shall be permitted to be connected to the load side of the service TOTAL AC kW: 5.000 kW disconnecting means of the other source at any distribution equipment on premises. Where distribution UTILITY INTERACTIVE PV SYSTEM equipment including switchgeor, switchboards or ponelboards are fed simultaneously by a primary source (E) 125A MAIN of electricity and one or more utility -interactive inverts, and where this distribution equipment is capable of SERVICE PANEL supplying multiple branch circuits or feeders or both, the interconnection provisions of CEC Section 1 P, 120/24OV, 60HZ 1 I I I I 2 - #10 AWG, PV WIRE 4 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 1 - #8 GEC, THW-2 IN 3/4" OR LARGER EMT CONDUIT (N) INVERTER SOLAR EDGE SE5000OH-US S[[S11] I \ AC I / DnCurrent Engineering Email: Projects(rlcurrciitrenci►ableseng.c Website: currentreneivableseng.com P.(951).254.5655 1. (19) CANADIAN 305W- CS6K-305MS MODULES wired and listed to UL1703 standards DC RAPID SHUTDOWN SWITCH (N) 30A, AC DISCONNECT SQUARE D DU221 RB TO LOAD (E) 100A / 2P MAIN BREAKER (CENTER FED) (N) 30A / 2P PV BREAKER -- ----- I I 3 - #10 AWG, THWN-2 j —— _ _ QRpFESSit Q�EMAN/j�, �`���, Digitally signed 1- #8 GEC, THWN 2 yL______________ s +rn y Methode IN 3/4" OR LARGER Y No. E 22012 " 0Martira Exp:09/30/21 g uha, PE EMT CONDUIT * * - �� Cl��ti �Q Date: 2020.02.19 �r£or CAI1�°� 16:20:20-08r00' ONNECT TO EXISTING UFER L-C 2. SOLAR EDGE SE5000H-US [S11] Inverter with integrated DC Disconnect and Arc Fault Protection. Attached with system electrical specifications and ground fault protected & listed to UL1741 standards. 3. Photovoltaic system ground will be tied into existing ground at main service from DC Disconnect/Inverter as per CEC Sec. 250.166(A). "The Grounding Electrode Conductor shall not be smaller than the neutral conductor and not smaller than 8AWG copper." 4. Equipment operating 150 volts or greater shall only be serviced or replaced by qualified personnel. Field protection may be in the form of conduit, closed cabinet or an enclosure which requires use of tools to open. 5. Solar Photovoltaic System equipment will be installed in accordance with requirements of Art. 690 of the 2019 CEC 6.Minimum height of conduit above roof to match temperature derating factor. 7.Photovoltaic DC conductors entering the building shall be installed in metallic raceway and shall be identified every 10 feet -- and within 1 foot above and below penetrations of roof/ceiling assemblies, walls, or barriers -- with minimum 3/8-inch-high white lettering on red background reading:"WARNING: PHOTOVOLTAIC POWER SOURCE" i� Electrical Contractor No: CLIENT: freedom C-10#1029644 FREEDOM FOREVER LLC 43445 Business Park Dr Suite 110, Temecula, CA 92590 LEBRE HEFTI, DENISE 52273 AVENIDA MADERO, LA QUINTA, CA 92253 (818) 634-3376 8. System Grounding Electrode conductor for PV system to be sized to meet the requirements of CEC 2019 table 250.66, not smaller than #8 CU AWG." 9. If the existing main service panel does not have a ground rod or ufer, it is the pv contractors responsibility install one. 10. Smoke alarms and carbon monoxide detectors will meet the necessary requirements per CRC R314, R315 11. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM. 12.Terminals of the disconnecting means may be energized in the open position. 13. A signage labeled "SOLAR LOADS ONLY" is to be installed on dedicated solar sub panel to be used for PV only. 14. Solaredge inverters are listed to UL1741 and UL1699B standards. 15. Solaredge Optimizers are listed to IEC62109-1 (class II safety) and UL1741 standards. 16. PV system is using continuous grounding method with #6 bare copper wire. 17. Conduit and conductor specifications are based on minimum code requirements and are not meant to limit up -sizing as required by field conditions DESCRIPTION DATE REVISION ELECTRICAL 12/9/19 1 CORRECTION S codes updated to 2019 CEC 2/19120 2 TITLE: DATE: 09/ 12/2019 DESIGN GREG ELECTRICAL BY: LINE DIAGRAM (E) UTILITY METER IID #75 366 847 SHEET: PV-3 inR in I Fn.,iR919 ,Ao nrpn• 125A Bus)' (1.2) = 150A Max Rating (120% of Bus) 3V Backfeed (30A) + Main Breaker (100A) = (130A 5 150A) See 705.12 of 2019 CEC SOLAREDGE P320 POWER OPTIMIZERS SOLAREDGE P320 POWER OPTIMIZERS I— — I I I I I I I I I I I 1 I I I- - I STRING-1 10 CANADIAN 305W- CS6K-305MS MODULES QTD 1K1f__7 9 CANADIAN 305W- CS6K-305MS MODULES 2 - #10 AWG, PV WIRE 1 - #6 AWG IN FREE AIR OR #8 AWG MUST BE IN EMT CONDUIT General Notes : TOTAL DC kW: 5.795 kW The output of a utility -interactive inverter shall be permitted to be connected to the load side of the service TOTAL AC kW: 5.000 kW disconnecting means of the other source at any distribution equipment on premises. Where distribution UTILITY INTERACTIVE PV SYSTEM equipment including switchgeor, switchboards or panelboards are fed simultaneously by a primary source (E) 125A MAIN of electricity and one or more utility -interactive inverts, and where this distribution equipment is capable of SERVICE PANEL supplying multiple branch circuits or feeders or both, the interconnection provisions of CEC Section 1 P, 120/240V, 60HZ 4 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 1 - #8 GEC, THW-2 IN 3/4" OR LARGER EMT CONDUIT (N) INVERTER SOLAR EDGE RAPID SHUTDOWN SE5000H-US [Sill SWITCH AC (N) 30A, AC 2 - #10 AWG, DISCONNECT PV WIRE D�+ SQUARE D DU221 RB o JUNCTION�fl - BOX_--� -===------ ---== =______=----=_ =__- ° -- a Current ' ----J (9-4Engineering Email: Projects n currentreneivableseng.t Website: currentreneivableseng.com P.(951).254.5655 1. (19) CANADIAN 305W- CS6K-305MS MODULES wired and listed to UL1703 standards No. E 22012 * Exp:09/30/21 yr CTR\GP," 9r�Or GAaia 2. SOLAR EDGE SE5000H-US [Sill Inverter with integrated DC Disconnect and Arc Fault Protection. Attached with system electrical specifications and ground fault protected & listed to UL1741 standards. 3. Photovoltaic system ground will be tied into existing ground at main service from DC Disconnect/Inverter as per CEC Sec. 250.166(A). "The Grounding Electrode Conductor shall not be smaller than the neutral conductor and not smaller than 8AWG copper." 4. Equipment operating 150 volts or greater shall only be serviced or replaced by qualified personnel. Field protection may be in the form of conduit, closed cabinet or an enclosure which requires use of tools to open. 5. Solar Photovoltaic System equipment will be installed in accordance with requirements of Art. 690 of the 2019 CEC. 6.Minimum height of conduit above roof to match temperature derating factor. 7.Photovoltaic DC conductors entering the building shall be installed in metallic raceway and shall be identified every 10 feet -- and within 1 foot above and below penetrations of roof/ceiling assemblies, walls, or barriers -- with minimum 3/8-inch-high white lettering on red background reading:"WARNING: PHOTOVOLTAIC POWER SOURCE" 1 � ElecMc lCont—tor No: CLIENT: freedol 11 C-10#1029644 FREEDOM FOREVER LLC 43445 Business Park Dr Suite 110, Temecula, CA 92590 LEBRE HEFTI, DENISE 52273 AVENIDA MADERO, LA QUINTA, CA 92253 (818)634-3376 Digitally signed I)D yMethode aniraguha, PE ate: 2020.02.19 r 16:20:20-08'00' TO LOAD (E) 100A / 2P MAIN BREAKER (CENTER FED) (N) 30A / 2P PV BREAKER -- - -------------------� ! ! 3-#10AWG,THWN-2 j -___--------__-_-. 1 - #8 EGC, THWN-2 1- #8 GEC, THWN-2 IL IN 3/4" OR LARGER EMT CONDUIT - CONNECT TO EXISTING UFER 8. System Grounding Electrode conductor for PV system to be sized to meet the requirements of CEC 2019 table 250.66, not smaller than #8 CU AWG." (E) UTILITY METER IID #75 366 847 9. If the existing main service panel does not have a ground rod or ufer, it is the pv contractors responsibility install one. 10. Smoke alarms and carbon monoxide detectors will meet the necessary requirements per CRC, R3141 R315 ...DING DIVISIC 11. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM. I� -VIEWED FOR, GGDI~: I 12.Terminals of the disconnecting means may be energized in the open position. .-'.r jP Ui E 13. A signage labeled "SOLAR LOADS ONLY" is to be installed on dedicated solar sub panel to be used for PV only. 14. Solaredge inverters are listed to UL1741 and UL1699B standards. 15. Solaredge Optimizers are listed to IEC62109-1 (class II safety) and UL1741 standards. 16. PV system is using continuous grounding method with #6 bare copper wire. 17. Conduit and conductor specifications are based on minimum code requirements and are not meant to limit up -sizing as required by field conditions REVISIONS: TITLE: SHEET: DESCRIPTION DATE REVISION DATE: 09/12/2019 ELECTRICAL 12/9/19 1 DESIGN GREG ELECTRICAL PV-3 CORRECTIONS BY: LINE DIAGRAM codes updated to 2019 CEC 2/19/20 2 .InR in FfIAFig19 i Eierrcai conr+ca No: CLIENT freedom C-1Q#1D29644 F c r< E v F R FREEDOM FOREVER LLC 43445 Business Park Dr Suite 110, Temecula, CA 92590 Tel: (800) 385-1075 S11HIM 1p &U61= - UtTER SOCKET LOAD CENTER LCw *1N tp Nv4 p ��yI,CR 1� r+r�►itr7lr�'�>wrCi� Yam.. ; 4 s� e No. E 22012 z * Exp:09130121 J1 CTR\(� �@ �r£or C atl���$► LEBRE HEFTI, DENISE 52273 AVENIDA MADERO, LA QUINTA, CA 92253 (818) 634-3376 Digitally signed yMethode aniraguha, PE Date: 2020.02.19 16:20:28-08'00' REVISIONS: DESCRIPTION DATE ELECTRICAL 12/9/19 CORRECTION S codes updated to 2019 CEC 2/19/20 /f�;t/ED LOIN r CODE; TITLE: DATE: 09/ 12/2019 REVISION 1 DESIGN EXISTING BY: GREG 2 SERVICE PANEL JOB ID.: F036219 SHEET: PV-4 UNIRAC LIGHT (E) S TILE UNIRAC SOLAR HOOK TYI STRUCTURE UNIRAC SOLAR HOOK (E) B STRI ^" 1/IODULES, DTHERS SUB FLASHING (OPTIONAL) I6"x3.5" SS LAG BOLT WITH MIN 2Y2" THREAD EMBEDMENT, SEALED PENETRATION ELECTRICAL CALCULATIONS BACKFEED BREAKER SIZING MAX. CONTINUOUS OUTPUT 2 1 A @ 240V 21 X 1.25 = 26.25AMPS 30A BREAKER - OK CEC 705.12 125 X 1.20 = 150 150 - 100 = 50A ALLOWABLE BACKFEED DE -RATED AMPACITY OF 10AWG CONDUCTOR @ 0.82 TEMPERATURE CORRECTION 40 X 0.82 = 32.80 AMPS - OK MATERIAL LIST QTY EQUIPMENT DESCRIPTION OPEN CIRCUIT VOLTAGE (Voc) : 39.9V CANADIAN 305W- MAX. POWER VOLTAGE (Vmp) : 32.7V 19 CS6K-305MS SHORT CIRCUIT CURRENT (Isc) : 9.91A MODULES MAX. POWER CURRENT (Imp): 9.33A PTC RATING: 280.3W SOLAR EDGE MAX. DC INPUT VOLTAGE : 480V SE5000H-US [S11] MAX. AC OUTPUT VOLTAGE RANGE: 211-240V 1 MAX. AC OUTPUT CURRENT: 21A WITH POWER MAX. AC POWER OUPUT: 5000W OPTIMIZERS CEC EFFICIENCY: 99 /o RATED DC INPUT POWER: 320V SOLAR EDGE MAXIMUM INPUT VOLTAGE: 48Vdc 19 P320 POWER MPPT RANGE: 8 - 48Vdc OPTIMIZERS MAX. INPUT CURRENT: 13.75Adc MAX. OUTPUT CURRENT: 15Adc 1 JUNCTION BOX 600VDC, NEMA 3R, UL LISTED 1 AC DISCONNECT 240VAC, 30A, NEMA 3R, UL LISTED 1 PV BREAKER 2 POLE, 240V, 30A 30 ATTACHMENTS "S" TILE HOOK 108' RAIL UNIRAC LIGHT RAIL UNIRAC LIGHT RAIL GROUNDING 32 MID CLAMPS MID CLAMPS 12 END CLAMPS UNIRAC LIGHT RAIL END CLAMPS 50, CONDUIT 3/4" OR LARGER EMT CONDUIT %rr r No. E 22012 t * t Exp: 09/30/21 1* srgl�ECTRICP��`e CA0 Digitally signed CODE by Methode OhfiPLIANCE �aniraguha, PE Date: 2020.02.19 16:20:38-08'00' n Elwl.leplCa bwdmNu � � freedom C-10#1029644 �•LEBRE F O R E V E R FREEDOM FOREVER LLC 43445 Business Park Dr Suite 110, Temecula, CA 92590 Tel: (800) 385-1075 CLIENT: HEFTI, DENISE 52273 AVENIDA MADERO, LA QUINTA, CA 92253 (818) 634-3376 REVISIONS: DATE: 09/12/2019ROOF TITLE: MOUNTING DETAILS, ELEC. CALCULATION & MATERIAL LIST SHEET: PV-5 DESCRIPTION DATE REVISION ELECTRICAL CORRECTION S 12/9/19 1 DESIGN BY: GREG codes updated to 2019 CEC 2/19/20 2 jog ID.: F036219 "WARNING" INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE (UNLESS BUSBAR IS FULLY RATED) 705.12(B)(2) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 690.56(C)(3) JO 0 F I I J/B DC I I I I I II I I 11 ### 690.31(G)(3) & (4), ### R324.7 I I "WARNING" I I PHOTOVOLTIC POWER SOURCE - _ - L L EVERY 10' ON COUNDUIT AND ENCLOSURES 0 C w w OC Z UgcMP Ccnjrncwn kc CLIENT: C-10#1029644 freedom FREEDOM FOREVER LLC 43445 Business Park Dr Suite 110, Temecula, CA 92590 Tel: (800) 385-1075 "WARNING" DUAL POWER SOURCES SECOND SOURCE IS PHOTO- VOLTAIC SYSTEM RATED AC OUTPUT CURRENT - 21 AMPS AC NORMAL OPERATING VOLTAGE - 240 VOLTS 690.54 PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT - 21 AMPS AC NORMAL OPERATING VOLTAGE - 240 VOLTS 690.15, 690.54 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT#E, DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY 690.56(C)(1)(A) "WARNING" ELECTRICAL SHOCK HAZARD. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. 690.13 PV SYSTEM DC DISCONNECT MAXIMUM VOLTAGE: 480V MAXIMUM CIRCUIT CURRENT: 21A MAX RATED OUTPUT CURRENT OF THE CONTROLLER OR DC -TO -DC CONVERTER:15A 690.53 LEBRE HEFTI, DENISE 52273 AVENIDA MADERO, LA QUINTA, CA 92253 (818)634-3376 NOTES: 1. CEC ARTICLES 690 AND 705 AND CRC SECTION R324 MARKINGS SHOWN HEREON 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SING MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK C. ARIAL FONT 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT POP -RIVETS OR SCREWS. CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS SHOWN. DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES FESSIpy Digitally signed by AN���i�y Methode �y� Maniraguha, PE E 22012 a Date: 2020.02.19 09/30/21 * 16:20:49-08'00' , CA 19 PV MODULE J JUNCTION BOX "ION PEV1E IEILF - : O CODE .,MAPLIAIV ! 17PTr, _ RY-._ INVERTER EQUIPPED WITH RAPID SHUTDOWN 6X8" TYP - CEC 705.10 REVISIONS: DESCRIPTION DATE I REVISION I DATE: 09/ 12/2019 ELECTRICAL I 12/9/19 CORRECTION S codes updated to 2019 CECI 2/19/20 ' DESIGN GREG BY: 2 Joe ID.: F036219 r_[9•1t 01*104IkgWOI MAIN SERVICE PANEL TITLE: LABELS SHEET: PV-6 1-10 11-20 21-30 31-40 41-50 51-60 1 2 3 ►1 5 C01 7 0 �7 10 gg� E7ecvca Canvuin ko• CLIENT: REVISIONS: TITLE: SHEET: IC-1091029644 e.\1� freedom LEBRE HEFTI, DENISE DESCRIPTION DATE REVISION DATE: 09/12/2019 r v x A 52273 AVENIDA MADERO, ELECTRICAL 12/9/19 1 DESIGN OPTIMIZER P\ /_7 FREEDOM FOREVER LLC LA QUINTA, CA 92253 CORRECTIONS BY: GREG V (818) 634-3376 codes updated to 2019 CEC 2/19/20 2 CHART 43445 Business Park Dr Suite 110, Temecula, CA 92590 JOB ID.: F036219 Tel: (800) 385-1075 AMBIENT TEMPERATURE SPECS RECORD LOW TEMP -3- AMBIENT TEMP (HIGH TEMP 2%) 36' CONDUIT HEIGHT 051 ROOF TOP TEMP 58' CONDUCTOR TEMPERATURE RATE 75' 'MODULE TEMPERATURE COEFFICIENT OF Voc -0.28%/°C PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT .80 4-6 .70 7-9 .50 10-20 P7cL:cn� cm"C* No: CLIENT: IC-10#1029644 freedom F C R F V F R FREEDOM FOREVER LLC 43445 Business Park Dr Suite 110, Temecula, CA 92590 Tel: (800) 385-1075 DC CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO JUNCTION BOX: (EXPECTED WIRE TEMP (In Celsius) 42' TEMP. CORRECTION PER TABLE (310.16) 1.00 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) 0.80 CIRCUIT CONDUCTOR SIZE 10 CIRCUIT CONDUCTOR AMPACITY 40A (REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X DC OPTIMIZER CURRENT 18.75A IDERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X 32.00A CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (18.75A) otherwise less the entry for circuit conductor size and ampacity DC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX TO INVERTER: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c) +22° (EXPECTED WIRE TEMP (In Celsius) 4Z+27 = 64' TEMP. CORRECTION PER TABLE (310.16) 0.65 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) 0.80 CIRCUIT CONDUCTOR SIZE 10AWG CIRCUIT CONDUCTOR AMPACITY 40A (REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X DC OPTIMIZER CURRENT 18.75A IDERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 'TEMP. CORRECTION PER TABLE (310.16) X 20.80A CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (18.75A) otherwise less the entry for circuit conductor size and ampacity LEBRE HEFTI, DENISE 52273 AVENIDA MADERO, LA QUINTA, CA 92253 (818) 634-3376 AC CONDUCTOR AMPACITY CALCULATIONS: FROM INVERTER TO MAIN SERVICE PANEL: No. OF INVERTER 1 (EXPECTED WIRE TEMP (In Celsius) 42. TEMP. CORRECTION PER TABLE (310.16) 0.87 NO. OF CURRENT CARRYING CONDUCTORS 3 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) 1 CIRCUIT CONDUCTOR SIZE 10AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 1.25 X MAX INVERTER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY (Result should be greater than (26.25A) otherwise less the entry for circuit conductor size and ampacity i �r� La a4e No. E 22012 a amrr * Exp:09/30/21 J'j. �FC TR1G�4 �4' ��FUf Cpt1F��`� REVISIONS: DESCRIPTION ELECTRICAL CORRECTION S codes updated to 2019 C ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY -IN LUG. Digitally signed Va Methode niraguha, PE Date: 2020.02.19 16:21:09-08'00' DATE REVISION 12/9/19 1 2/19/20 1 2 DATE: 1 09/12/2019 DESIGN BY: I GREG WIRING CALCULATION TITLE- SHEET: WIRING PV-8 CALCULATION JOB ID.: I F036219 SUPERPOWER CS6K-290 1 295 1 300 1 05MS Canadian Solar's new Superpower modules with Mono-PERC cells significantly improve efficiency and reliability. The innovative technology offers superior low irradiance performance in the morning, in the evening and on cloudy days, increasing the energy output of the module and the overall yield of the solar system. KEY FEATURES U 11 % more power than conventional modules �� CanadianSolar (25 linear power output warranty �ycan� 10 product warranty on materials years and workmanship *Black frame product can be provided upon request. MANAGEMENT SYSTEM CERTIFICATES* Excellent performance at low irradiance ISO 9001:2008 / Quality management system of up to: 97.5 % ISO 14001:2004/ Standards for environmental management system OHSAS 18001:2007 / International standards for occupational health & safety High PTC rating of up to: 91.90 % Improved energy production due to low temperature coefficients IP68junction box for long- term weather endurance * Heavy snow load up to 6000 Pa, wind load up to 4000 Pa * -For detail information, please refer to Installation Manual. PRODUCT CERTIFICATES* IEC 61215 / IEC 61730: TOV-Rheinland / VDE / CE / MCS / CEC AU / JET UL 1703 / IEC 61215 performance: CEC listed (US) / FSEC (US Florida) UL 1703: CSA / IEC 61701 ED2: VDE / IEC 62716: VDE UNI 9177 Reaction to Fire: Class 1 IEC 60068-2-68:SGS JTake-e--wwaaay 1� cv�rC C BWa1' 1 i C " Please contact your local Canadian Solar sales representative for the specific product certificates applicable in your market. CANADIAN SOLAR INC. is committed to providing high quality solar products, solar system solutions and services to customers around the world. As a leading PV project developer and manufacturer of solar modules with over 21 GW deployed around the world since 2001, Canadian Solar Inc. (NASDAQ: CSIQ) is one of the most bankable solar companies worldwide. CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1 K 1 E6, Canada, www.canadiansolar.com, support@canadiansolar.com ENGINEERING DRAWING (mm) Rear View Frame Cross Section A -A -T Mounting Hate ELECTRICAL DATA I STC* 290MS 295MS 30OMS 305MS Nominal Max, Power (Pmax) 290 W 295 W 300 W 305 W Opt. Operating Voltage (Vmp) 32.1 V 32.3 V 325 V 32.7 V Opt. Operating Current (Imp) 9.05 A 9.14 A 9.24 A 9.33 A Open Circuit Voltage (Voc) 39.3 V 39.5 V 39.7 V 39.9 V Short Circuit Current (Isc) 9.67 A 9.75 A 9.83 A 9.91 A Module Efficiency 17.72% 18.02% 18.33% 18.63% Operating Temperature -400C - +851C Max. System Voltage 1000 V (IEC) or 1000 V (UL) Module Fire Performance TYPE 1 (UL 1703) or CLASS C (IEC 61730) Max. Series Fuse Rating 15 A Application Classification Class A Power Tolerance 0 - + 5 W * Under Standard Test Conditions (STC) of irradiance of 1000 W/W, spectrum AM 1.5 and cell temperature of 250C. ELECTRICAL DATA I NMOT* CS6K 290MS 295MS 30OMS 305MS Nominal Max, Power (Pmax) 215 W 218 W 222 W 226 W Opt. Operating Voltage (Vmp) 29.7 V 29.8 V 30.0 V 3D.2 V Opt. Operating Current (Imp) 7.24 A 7.32 A 7.40 A 7.48 A Open Circuit Voltage (Voc) 36.8 V 37.0 V 37.2 V 37.4 V Short Circuit Current (Isc) 7,81 A 7.87 A 7.93 A 8.00 A "Under Nominal Module Operating Temperature (NMOT), irradiance of BOO W/m', spectrum AM 1,5, ambient temperature 20'C, wind speed 1 m/s. CS6K-295MS / I-V CURVES A A 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 ■ 1000 W/m' 5°C ■ rtt BOO w/m� 25•C ■ 600 W/m' 45'C ■ 400 W/m' 65-C ■ MECHANICAL DATA Specification Data CeIIType Mono -crystalline, 6 inch Cell Arrangement 60(6x10) Dimensions 1650x992x40 mm (65.Ox39.1 x1.57 in) Weight 18.2 kg (40.1 Ibs) Front Cover 3.2 mm tempered glass Frame Material Anodized aluminium alloy J-Box IP68, 3 diodes Cable 4.0 mm2 (IEC), 12 AWG (UQ, 1000 mm (39.4 in) Connector T4 series Per Pallet 27 pieces, 538 kg (1186.1 Ibs) Per Container (40' HQ) 756 pieces TEMPERATURE CHARACTERISTICS Specification Data Temperature Coefficient (Pmax) -0.39 %/°C Temperature Coefficient (Voc) -0.29%/°C Temperature Coefficient (Isc) 0.05 % / °C Nominal Module Operating Temperature (NMOT) 42 t 2 °C PERFORMANCE AT LOW IRRADIANCE PARTNER SECTION Excellent performance at low irradiance, with an - average relative efficiency of 97.5 % for irradiances between 200 W/m2 and 1000 W/m2 (AM 1.5, 25°C). The aforesaid datasheet only provides the general Information on Canadia n Solar products and, due to the ongoing innovation and Improvement, please always contact your local Canadian Solar sales representative for the updated information on specifications, key features and certification requirements of Canadian Solar products in your region. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. ..... ......... .... ........... ......... CANADIAN SOLAR INC. Aug. 2017. All rights reserved, PV Module Product Datasheet V5.551 _EN Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US / SE1000OH-US / SE1140OH-US ladwaL ® salary „HD..,. a ■� (6 aclar-W -= I ID ,... � 14^ 0 r v • Ir Optimized installation with HD -Wave technology / Specifically designed to work with / Extremely small power optimizers / Record -breaking efficiency / Built-in module -level monitoring / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for / Optional: Revenue grade data, ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5% accuracy) / UL1741 SA certified, for CPUC Rule 21 grid compliance Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US OUTPUT Rated AC Power Output 3800 @ 240V 5000 J00 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 3800 @ 240V 5000 5000 @ 208V 6000 @ 240V 7600 10000 10000 @ 208V 11400 @ 240V VA Maximum AC Power Output 3000 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min. -Nora. -Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211 - 240.2641 AC Output Voltage Min.-Nom.-Max. ✓ _ ✓ ✓ Vac (183 - 208 - 229) AC Frequency (Nominal) 59.3 - 60 - 60.5111 Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output - 16 - 24 - 48.5 A Current @2%V GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Yes Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 1 15500 17650 W Maximum DC Power @208V - 5100 7750 - 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240VR1 8.5 10.5 13.5 16.5 20 27 30,5 Adc Maximum Input Current @208VR1 - 9 - 13.5 - - 27 Adc Max. input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency gg 99 @ 240V 98,5 @ 208V % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces Revenue Grade Data, ANSI C12.20 Rapid Shutdown - NEC 2014 and 2017 69012 STANDARD COMPLIANCE RS485, Ethernet, ZigBee (optional), Cellular (optional) Optional"' Automatic Rapid Shutdown upon AC Grid Disconnect Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS Output Conduit Size /AWG Range 3/4" minimum / 14-6 AWG 3/4' minimum /14-4 AWG DC Rar Conduit Size / # of Strings AWGG Range / 3/4' minimum / 1-2 strings / 14-6 AWG 3/4' minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22110 1 25.1 / 11.4 1 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -25 to +60t41(-40'F / -40'C option)() 'F / °C Protection Rating NEMA 4X (Inverter with Safety Switch) m For other regional settings please contact SolarEdge support C Solar, a r R higher current source may 5E used; the inverter will limit is input current to the values stated �'%Revenue grade inverter P/N: SExnaH-USOOONNC2 sola redge.com For power de -rating information refer to: hrtps://www.solaredge.com/sites/defaulVfiles/se-temperature-derating-note-na pdf Ri -40 version P/N: SExxxxH-US000NNU4 ® SolarEdge Technologies. Inc All rights reserved SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc All other trademarks mentioned herein are trademarks of their respective owners. Date: 1Zf2018/V01/ENG NAM Subject to change without notice. RvHS Power Optirnizer For North America P320 / P340 / P370 / P400 / P405 / P505 l PV power optimization at the module -level / Specifically designed to work with SolarEdge inverters / Up to 25% more energy / Superior efficiency (99.5%) / Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading / Flexible system design for maximum space utilization r�� 0J -o N m A / Fast installation with a single bolt / Next generation maintenance with module - level monitoring / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) / Module -level voltage shutdown for installer and firefighter safety Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 INPUT Rated input DC Powers" 320 340 60 400 405 1 505 836 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 80 1250 Vdc MPPT Operating Range 8 - 48 8-60 8 - 80 12.5 -105 12.5 - 83 Vdc Maximum Short Circuit Current (I 11 101 14 Adc Maximum DC Input Current 13.75 12.63 17.5 Adc Maximum EfScienry 99.5 % Weighted ElEdesxy 98.8 98.6 % overvcrltage ealegpry i 0 OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OF Safety Output Voltage per 1 t 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class 8, IEC61000-6-2, IEC61000-6-3 SaW IEC62109-1 (class II safety), UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System 1000 Vdc CQmpallb)e inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 129 x 153 x 27.5 / 5.1 x 6 x 1.1 129x153x33.5/ 5.1x6x1.3 129x159x49.5/ 5.1x6.3x1.9 129x162x59/ 5.1x6.4x2.3 mm/in Weight firKludlny cables) 630 / 1.4 1 750 / 1.7 845 / 19 1064 / 2.3 gr / lb Input Connector MC4P1 Output Wire Type / Connector Double Insulated; MC4 Outpul Wire Length 0.95 / 3.0 1,2 / 3,9 m / ft Input Wire Length Q16 / 0.52 m / ft Operating Temperature Range -40 - +85 / -40 - +185 'C /'F Protection Raling IP68 / NEMA6P Relative Humidity 0 -100 % 'r, Rated SEC power of the module. Module of up to +5% power tolerance allowed r. NEC 2017 requires max input voltage be not more than 80V Q For other connector types please contact SolarEdge Minimum String Length P3320 P340, P370, 8 10 18 (Power Optimizers) P405 / P505 6 8 14 Maximum Suir g Length 25 25 50� (Flower tampers) 5700 (6000 with Maximum Power per String SE7600-US - SE11400- 5250 6000M 12750m W US) Parallel Strings of Different Lengths or Orientations Yes For detailed strirg sizing information refer to: httpV/www.solaredge.corrV5ites/default 61es/stririg_5izing-na.pctf It is not allowed to mix P405/P505 with P320/P340/P370/P400 in one string A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 3UV requirement m For SE14.4KU5/SE43,2KUS: It is allowed to install up to 6,500W per string when 3 strings are connected to the inverter (3 strings per unit for SE432KUS) and when the maximum power difference between the strings is up to 1,000W For SE30KUS/SE333KUS/SE666KUS/SE100KUS: It is allowed to install up to 15,000W per string when 3 strings are connected to the inverter (3 strings per unit for SE66.6KUS/SE100KUS) and when the maximum power difference between the strings is up to 2,006W solaredge.eom solar =se Al SolarEdge Technologies Ltd. All rights m bra em arks oftheir the SolarEdge logo, OPnMQED BY S/ENG N N are da to rtrs or registered trademarks or SdarrdgeTeNrrologies, Irie C E RoH S All other trademarks mendaned herein are trademarks oftheir respective owners Date: 1Jj101B/VOl/ENG NAM Sutry'ect to change without notice June 20, 2014 Mr. Meir Adest SolarEdge Technologies Ltd 6 Ha'Harash St. HOD HASHARON, ISRAEL 3933 US Route 11 Cortland, NY 13045 Telephone: (607) 753-6711 Facsimile: (607) 756-9891 www.intertek.com Letter Report No. 101703554CRT-001 Project No. G101703554 Ph: +972.9.957.6620 email: meir.a@solaredge.com Subject: ETL Evaluation of SolarEdge Products to NEC Rapid Shutdown Requirements Dear Mr. Meir Adest, This letter represents the testing results of the below listed products to the requirements contained in the following standards: National Electric Code, 2014, Section 690.12 requirement for rapid shutdown. This investigation was authorized by signed Quote 500534459 dated 06/10/2014. Rapid shutdown test were perform at SolarEdge Technologies Ltd, 6 Ha'Harash St HOD HASHARON, ISRAEL and witness by Intertek personal on 06/17/2014. The evaluation covers installations consisting of optimizers and inverters with part numbers listed below. The testing done has verified that controlled conductors are limited to not more than 30 volts and 240 volt- amperes within 10 seconds of rapid shutdown initiation. Applicable products: Y Power optimizers: o PBxxx-yyy-zzzz; where xxx is any number, 0-9, up to a maximum value where xxx = 350; yyy could be AOB or TFI; and zzzz is any combination of four letters and numbers. o OP-XXX-LV, OP-XXX-MV, OP-XXX-IV, OP-XXX-EV; where xxx is any number, 0-9. o Paaa, Pbbb, Pccc, Pddd, Peee; where aaa, bbb, ccc, ddd, eee is any number, 0-9 to a maximum upto aaa=300, bbb=350 ccc=500, ddd=600, eee=700. o Pxxx, Pyyy, Pzzz, Pmmm, Pnnn and P000; where xxx, yyy, zzz is any number, 0-9 to a maximum up to xxx=300, yyy=350, zzz=500; where mmm, nnn, 000 is any number, 0-9 to a maximum up to mmm=405, nnn=300, 000=350 • 1-ph Inverters: o SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE10000A-US / SE1140OA-US when the SolarEdge rapid shutdown cable labeled "MCI-CB-xxxxx-x" which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is any number; inverter part number may be followed by a suffix Page 1 of 2 This report is for the axcluslve use of Inteneys Client and Is prMlOW pUr3uaflt to the agreement between Intadek end its Client lnlarlW%fesponaIJAIfy end Ilatiltity are Ilrnited to the farms and cond+kons of the agreement. Inlertek assumes no Ilabtlity to any party, other then Io the Chant in accordance with ilia agreement, for any Ions. expanse a dantsge ammionod by the use of Nis report. Only ilte Client is nupxxlzed to pemdl coWng or deuibuWm of pd8 fepwl and then only in lls entirety Any use at the Irltunek name of one oI its marks for the sale or advai-Wenent of the tested material, pfnduct of ser-ACe must first be approved In wriling by Intertek. The obeervaUdns end teal re&dte In thtlk report are relevant only the snnple te5led. This roped by itself does not Imply that she malerlal, product or service Is or has ever been under an Intenak cerlkAcation program, 0 0 �® _r. _ 6fdAb ilnterlekll ertek Intertek Intertek Intertek Intertek Intertek Int Intertek Testing Services NA, Inc SD 12.1.2 (11/11/10) Informative SolarEdge Technologies Ltd • 3-ph Inverters: Letter Report 101703554CRT-001 June 201h, 2014 o SE9KUS / SEIOKUS / SE20KUS when the SolarEdge rapid shutdown cable labeled "MCI-CB-xxxxx- x" which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is any number; inverter part number may be followed by a suffix This letter report completes this portion of the evaluation covered by Intertek Project No.G101703554. If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the undersigned. Please note, this Letter Report does not represent authorization for the use of any Intertek certification marks. Completed by: Radhe Patel Reviewed by: Howard Liu Title: Signature: Engineering Team Lead W�) CJ C�.`"0' Title: Signature Staff Engineer Date June 20 , 2014 Date: June 20 , 2014 Intertek Testing Services NA, Inc. Page 2 of 2 SD 12.1.2 (11/11/10) Informative ILARMUUNT m ■■ U N SOLARMOUNTnow U N I RAC CONCEALED UNIVERSAL CLAMPS s OPTIONAL FRONT TRIM sPONIRAC 25 YIA 1111t`fsil I NI�FlHRHIY THE PROFESSIONALS' CHOICE FOR RESIDENTIAL RACKING lilt, Ill Ilpllgl«I pi lllllplll@I NIIIIIIIIIIIIINUIIIIryHII I II I I I 111111 IIIIIIIIIIIIIH4,Ifllll,•1plll n I I III I lkII LI I I I I HlI I I II I II I I I IIH IIIIIIIInuu...... I ............... luuu..•.un.... i., .•...un . ........... BEST INSTALLATION EXPERIENCE • CURB APPEAL* COMPLETE SOLUTION • UNIRAC SUPPORT TRUST THE INDUSTRY'S BEST DESIGN TOOL Stall Ihe design elor,ess ter evely ploe:cl I o ll 11 hillldel en hnr. llc:ipil Inlll li's a Bleat .fay 111 S1VC 11mC an(I Illellny. BETTER SYSTEMS ONE SYSTEM - MANY APPLICATIONS Quickly sel nmdules flusil to Ihr loin un :Ir.r,u pdelu:d nniki llnenl a lall!c varll;ly el rnonules In Poruad er Landscape. lilt the spsImll nil eo Ilal ill In ;low loots Coluponculs avadahle ill mill- clear. •;nld d;elr ime;i1w; w npluulvc ynel dwopli Ilnancwh and ar.stlictics. BETTER RISLIUS MAXIMIZE PROFITABILITY ON EVERY JOB Trusl Uonar, to help you Inhunnze hulk syslum and I;Ihnl cost. icon Ihr. roue Ihr: Lois Is qunled to the tune your learns get ell the null 1 a:,1r.1 Insiallc 1 os:. Nasle Mole fholil WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Piolesslonal supporl Im prolessmu;ll Im;lalkle ,led desIpllvls roll n;IV( Ieers�.. to om lecluocal suppoll and lraoonf. i nnlu AAllmirv1:I your :mIlllnll nrru yr Ijo you covered. Visit Ulular—comisulaimmool let limn: mionnalunl � VI11IIAINNIIAI lI lI)AI)IIINII Ln® Ncl UL2703 IJ SY;'lLMlllll ILA?�`IIIICAIIIIN CONCEALED UNIVERSAL LNDCLAMPS UNIVERSAL SEI F STANDING MIDCLAMPS 1 END CAPS INCLUDED WITH EVERY ENOCLAMP U BUILDER ONLINE DESIGN TOOL SAVES TIME & MONEY Visll dlalp•n unnac.',:nnl U41AIIRAC (' b q_1 M1-_ � ¢ p °, '": WA N 1— I 01 GANI U T 111' 1F. a` 1LW cif &# , _ I cl III It III] I ISI Itllfrl (XPIERIENCEI I)IIAllly IIIIh III[IIIC WAR[IAMIV ; I i111Ci1A11IN[At IIIN TECHNICAL SUPPORT Ihmac's leelunr,al slglpnrl toanl r., dcdir,alr.n lu :uu;wlulnF qucshons .� iddmsslnc Nmir m Heil limn Ali online liblaly of Ilocmliwim 111611111110. icooll", slanlpcd lellcls %Inrl tochmcal (Mki ?hilul:: )lushly ,mlplihes void Immolhng ;Ind proleel dlanlenp muna!ss;- CERTIFIED QUALITY PROVIDER Ihelac Is Ill! only I IV I"leuelief' vtnehn wills ISI I I;i;l I licdllenr• 101 9111.I1'711111i, hilllll:ill(I� :Illd lli.`:�AS III.IIII-'�--'lllll ',vhicll nlu;ws vdr dnlivul Ihu mPlue;i tllanliauls Im lit. II.Xr;ellrllce ,lod rIIIIlI1111111cill In iii'd iII;IX BANKABLE WARRANTY hunt leave feel 01011.10 io r,innlec. Ihlonr. iar, Lilo hlnmclnl slmnp•Ih fo Ilacll iuu pinliuclti anu Ir.iiurc full n1 Maur plan;o ni uluul koowilig pil nni plovldilgl nledu(;,: III crcullhmoi mi;i1ily SIIIAIiM )UNl Is ru ciod by :I :';, vial Iinlihi ll pludifl:1 vmIlmiliy anti -.'., uml limilcn hnn;ll vmll;ndy. c.NIBANCt. YOLnC AIIf)I,1 'Allisl ;llI,AI I: V VAC'VINIC, 1.111 (1 41Af:RNt .+?v t Nr.,IIll 1N1 b,f€.'I `I t 11 A 111i A ilI I 11'1 V :iWI°I Y 1 I hV1 SOLARHOOKS 1 .e�UNIi�AC SOLARHOOKS is a complete line of versatile attachment solutions for tile roofs. Simple to install and designed for maximum convenience, SOLARHOOKS includes an assortment of tile hooks to solve any challenge, from universal hooks to specific shapes for flat and Spanish tiles. SOLARHOOKS are kitted with lag bolts for maximum convenience and have a bead blasted stainless steel finish. With SOLARHOOKS, you have everything you need for a quick, professional tile installation. :L1UNIRAC YEAR 1UR-SYSTEM WARRANTY SIMPLE INSTALLATION VERSATILITY ASSORTMENT Lag bolts & EPDM washers included Available with multiple hole pattens and slotted Designs for Universal, Flat & Spanish tile connections for adjustabi lity •[:juNIRAC SOLARHOOKS •• APPLICATION GUIDE p I MODEL PART NUMBER I I IKLINIV sa mi riF �n,r:,; SOLARHOOK1 "Aiis J^de �. s'i f. �:; 11aur s�St;:ei 11K SPANISH SIDI 1AI C111 "J4 11c SOLARHOOK 014S7iS MATERIAL dlaslf.; ?Ui Stfc .�s��c! Rad �.fs.�� J "air'r zs S'c,.l JBla�i "i 04 strC APPLICATION s�[t>gluAi �,rnnx n�ia fs inrx: f c�nr� Hrn 17e..arnQl v�yv.•!h!��Wrs USES EXISTING TILES RAIL OR RAIL -LESS �? Raii ad Rail MOUNTING METHOD �irc .1f, uu d _ cr. dr's'oi:• F.itk!Anmr! DIRECT MOUNT, NO [-FOOT REQUIRED y y ADJUSTABLE FLATTILE VO STILE VO W TILE UNIVERSALTILE SIMPLE INSTALLATION vo NO TILE MOD. REQUIRED y y WARRANTY 25 Yew 25 Veai 25 `leaf 251'eai m 0 o N �71 ~CD CD Q.�3. CD � CD CDCD c CD (D CA CD m 00 O �o CD ,rt `d OCDt CD W P ,O CD cr Sy 0 p CD CD NO < o' C-D CD � c ° o GJ CD C� 0- �o o O ' v, o Cl, CD < NO CD n * Ec,srlet F, N y 5 Acn n n xo fi p o� -n C7 w w Zv m TCl 0 � n � -, CO p, CD o�q cr cn St o ID Ntt ,CDC, � � ttTl � O P• n �' 0 ►i 0 0 cn 0 o 1 0 CDCD r•CD CD CAD y • (JQ CD CD CD V '_h CD 0 CD Q CD C ~ O a BCD ° 0 PA CD CD 00 CD a 0 CD O~ ....� .. . paw BCD �(aD CD ,COD �C CD nOA O 00• a ° CD 0- CD FD CD r O .C. CD Q, CD CD CD CD oCD CD d a r RCD CD �. ' CD v�' O CD CD oCD CD �O o, CD CD CD C rn A N J O ■0 0 (D d CD m :� rt (D N CO (D F-N• K(Drt (n 1 (D(DGO� W K C w mn to::sCFO N Fl- H• rt rt 0 Na p :J za 0 kQ toCD ., � m rt rt 0 mmmm°, 0 mn•• w rt ro a ` m P- K o Ox 0 �N� O m N W rt H (fin cn ¢ rt m rt `� 170 a i]. N m ._ • rt I--' m " h F-+ C>a 000 0 F'• F'• 0 a ro K cKDrt' m�av K �4 0 0 rt °�, m a F� rr K��a CD 0 .... w 0 a rt P• : m G (n m • Q. 0 m N N 0 w N O Ul 5 C w 0 o K O H O. (D n .. z r� co 0 N C: > Q g mK�O� K O H• G L 0 �c r: z co J N 0 N CA 00 N r-+ Q1 0 1�► 0 n c�