BSOL2019-003178-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT SOLAR/RESIDENTIAL GREATER THAN 1OKW BSOL2019-0031 47625 VIA MONTIGO 643120030 HANDLER / 13.065kW PV SYSTEM $39,000.00 Applicant: DEVIN FONTANE - FREEDOM FOREVER LLC 43445 BUSINESS PARK DR STE 110 TEMECULA, CA 92590 ),A, T FEE-2 h 2020 0 C#Y OF LAQUINTA &%ftbNELQPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B C10. C46, C39 License No.: 1029644 . Date: Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/25/2020 Owner: FRANCINE HANDLER 47625 VIA MONTIGO LA QUINTA, CA 92253 Contractor: FREEDOM FOREVER LLC 43445 BUSINESS PARK DR STE 110 TEMECULA, CA 92590 (951)319-4975 Llc. No.: 1029644 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of th oCJFfor which this permit is issued. have and will maintain workers' compensation insurance, as required by Se i n 700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Y I Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. I1G7/ I .. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work fbr 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above - mentioned property for inspection purposes. Dateaignature (Applicant or Agent) Date: 2/25/2020 Application Number: BSOL2019-0031 Property Address: 47625 VIA MONTIGO APN: 643120030 Application Description: HANDLER / 13.065kW PV SYSTEM Property Zoning: Application Valuation: $39,000.00 Applicant: DEVIN FONTANE - FREEDOM FOREVER LLC 43445 BUSINESS PARK DR STE 110 TEMECULA, CA 92590 Owner: FRANCINE HANDLER 47625 VIA MONTIGO LA QUINTA, CA 92253 Contractor: FREEDOM FOREVER LLC 43445 BUSINESS PARK DR STE 110 TEMECULA, CA 92590 (951)319-4975 Llc. No.: 1029644 Detail: 13.065kW SOLAR ARRAY - (39) LG 335N1C-A5 335W MODULES + SOLAR EDGE SE 10000H + 60AMP SQUARE D AC DISCONNECT, EXISTING CENTER FED MSP DERATED TO 175 AMP WITH EXISTING 100 AMP SUBPANEL [4,623.15 SF ROOF AREA] 2019 CALIFORNIA ELECTRICAL CODE. Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT QTY AMOUNT PV SYSTEM GREATER THAN 10KW 101-0000-42403 0 $40.25 DESCRIPTION ACCOUNT CITY AMOUNT PV SYSTEM GREATER THAN 10KW PC 101-0000-42600 0 $40.25 Total Paid for ELECTRICAL 2019: $80.50 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $101.97 Total Paid for PERMIT ISSUANCE: $101.97 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Qwkra CALIFORNIA PERMIT # PLAN LOCATION: Project Address: `� Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: 1 Applicant Name: Address: '1 414 S u i n City, ST, Zip: e, Telephone: _ l 5 l a j 9 Lf!� I Email: J�r-ee- r,) Valuation of Project $ 5` t , 0 0 V (,6 }'''1 Contractor Name: it e & �—D � 9� New SFD Construction: Adcite ss: 7 ' Conditioned Space SF City, St, Zip `� C a5� Garage SF Telephone: 0\ "l l Patio/Porch SF Email: Fire Sprinklers SF State Lic: ( (D ( p-ac ity Bus Lic: L -+6(A8q 5 Arch/Eng Name: Construction Type: Occupancy: Address: Grading: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: \A an , New Commercial /Tenant Improvements: Address: y `� (DaCJ , J T c, m o I- O Total Building SF City, ST, Zip L C,_ Construction Type: Occupancy: Telephone: � Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 (760)777-7125 WWW.LAQUINTACA.GOV Current Renewables Engineering Inc. Freedom Forever LLC 19435 Fortunello Ave Current yr�vfxcedomforerer.com Riverside CA 92308 Engineering 4344S Business Park Drive Methode@currentrenewableseng.com Suite 110, Temecula 92590 951-254-5655 freedom 2/10/2020 FAULT STUDIES PER NEC 2017 705.12(9)(2)(3)(e) Project Scope: Rooftop Selar Py sr Customer Address: 47625 VIA MONTIGO, LA QUINTA, CA 92253 Customer Names: HANDLER, FRANCINE Project Name: HANDLER, FRANCINE UTILITY TRANSFORMER(Estlmated): 50 WA 120/240V, Single phase, 60HZ Utility: IMPERIAL IRRIGATION DISTRiCT([ID) ro�,� Utility Available Fault Current: �, C ! MA Digitally signed Southern California Edison, Electrical Service Requirements 13.1: "The Company's Contribution to the available short-circuit current at the service entrance will not Q0. � IIy� Z+� � �� b Methode y exceed 10,000 A for single-family dwelling, duplexes, or individually metered mobile homes that use self-contained type Company meters." Maniraguha, PE w y ,,, ce No. E 22012 Pacific Gas and electric Company, service requirements 2016, 5.7.2: * Exp: 09/30/21 * Date. "PG&E design its facilities so that the short-circuit duty at the service termination will not exceed tC` ~ti, 2020.02.10 10,000-amps symmetrical for new, single —family, residential applicants that are supplied by an individual service drop or lateral that is rated at 225 amps or less. This service incudes mobile 9j� 07:49:41 -08 00 4��+ (f homes and duplexes.' mi PV SYSTEM CONTRIBUTION @MAIN BUS: SOLAREDGESE1000OH-US VARIABLES VALUES I — 42 I=Fault current available from inverter(s)[A], Max cont. output current L= 5 L=Inverter output conductorlength[ft] PF— 2 Phase factor(1.732 for 3 phase, 2 for single phase) E_LL 240 E_LL= Line to line voltage[V] N 1 N=Number of parallel conductors per phase[1 for 1 phase, 2 for 3 phase] Conductor Size #6 AWG, CU Conductor C Value 2425 C=1/Z[per feet], Z=conductor impendance(Ohms) F factor = (I x L x PF)/(N x C x E—LL) 0.0007216494845 M factor = 1/(1 + F factor) 0.9992788709 Available Short -Circuit Current(AFC) at Fault = I x M 42 Amps TRANSFORMER TO FIRST HANDHOLE VARIABLES VALUES DESCRIPTION & UNITS I = 12,255 I=Fault current available at first handhole from utility transformer[A]. L= 30 L=Conductor length from transformer to service entrance[ft] (Estimated) PF= 2 Phase factor(1.732 for 3 phase, 2 for single phase) E_LL 240 E_LL= Line to Line VoltageM N 1 N=Number of parallel conductors per phase[3 for 1 phase, 2 for 3 phase] Ublity Conductors Size #350 KCMIL, AL Conductor C Value 15082 C=1/Z[per feet], Z=conductor impendance(Ohms) F factor = (I x L x PF)/(N x C x ELL) 0.2031378789 M factor = 1/(1 + F factor) 0.831159934 Available Short -Circuit Current(AFC) at Fault = I x M 10186 Amps UTILITY CONTRIBUTION @SERVICE ENTRANCE: VARIABLES VALUES DESCRIPTION & UI I = 10,186 I=Fault current available from utility[A]. L= 30 L=Conductor length from transformer to service entranw[fl PF— 2 Phase factor(1.732 for 3 phase, 2 for single phase) E LL 240 E_LL= Line to Line Voltage[V] N 1 Utility Conductors Size #350 KCMIL, AL Conductor C Value 15082 C=1/Z[per feet], Z=conductor impendance(Ohms) CITY OF LA Q U I NTr\ (Es[ima[eT UILDING DIVISIOi J REVIEWED FOR CODE COMPLIANCE F factor = (I x L x PF)/(N x C x E—LL) 0.1688436547 M factor = 1/(1 + F factor) 0.8555464163 LDATE----=l3Y__Available Short -Circuit Current(AFC) at Fault = I x M 8715 Amps_ UTILITY + PV SYSTEM CONTRIBUTION = BMAmps will not exceed 22kAIC ratinn of the navel. ZKQ PHOTOVOLTAIC SYSTEM PV SYSTEM SUMMARY: 13.065 KW CITY NOTES: SITE LOCATION: THIS PROJECT COMPLIES WITH THE FOLLOWING: _ ROOF MOUNT RESIDENTIAL PHOTOVOLTAIC SYSTEM 2016 CALIFORNIA BUILDING CODE (CBC) CITY OF LA OUINTA SYSTEM SIZE (DC) STC: 39 X 335= 13065W DC 2016 CALIFORNIA ELECTRICAL CODE (CEC) BUILDING DIVISION J 2016 CALIFORNIA FIRE CODE (CFC) PTC: 39 X 311.10 = 12132.90W DC 2016 CALIFORNIA PLUMBING CODE REVIEWED FOI l 2016 CALIFORNIA MECHANICAL CODE CODE SYSTEM SIZE (CEC-AC) 39 X 311.10 X 99% = 12011.57W AC 2016 CALIFORNIA ENERGY CODE COMPLIANCE MODULES 39 X LG335N1 C-A5, 335W MODULES 2016 CALIFORNIA RESIDENTIAL CODE 2016 CALIFORNIA ADMINISTRATIVE CODE �---- DATE_: _--.�"`�--EY_ _ 47625 Via IMonii a 2 INVERTER 1 OH -US S11 SOLAR EDGE SE 000 [ ) AS ADOPTED BY CITY OF LA QUINTA =__ -- -- 8 � ROOF FLAT TILE MODULES SHALL BE TESTED, LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 1703. THE FIRE CLASSIFICATION SHALL COMPLY WITH TABLE ' TILT 19 PITCH 1505.10F THE CALIFORNIA BUILDING CODE BASED ON THE TYPE OF CONSTRUCTION OF AZIMUTH 185° THE BUILDING. CRC SECTION R902.4 SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTION R314 AND Via Ft 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. �,�nce vre Florence < RAFTER/TRUSS SIZE 2" X 4" TRUSSES @ 24" O.0 & RESIDENTIAL BUILDING UNDERGROUND ADDITION OR IMPROVEMENTS SHALL REPLACE ATTACHMENT TYPE FLAT TILE HOOK WITH UNIRAC LIGHT RAIL NON -COMPLIANT PLUMBING FIXTURES WITH WATER CONSERVING PLUMBING FIXTURES IN < ACCORDANCE WITH CGBSC i�- EXISTING 200 AMPS MSP WITH NEW DERATED 175 SECTION301.1.1 AND CIVIL CODE 1101.1 AS FOLLOWS: MAIN SERVICE PANEL AMP MAIN BREAKER ON CENTER FEED —WATER CLOSETS: 1.6 GPF (GPF= GALLONS PER FLUSH) SITE LOCATION FAUCETS (ALL INTERIOR) 2.2 ( GPM = GALLIONS PER MINUTE) INTERCONNECTION PV BREAKER TIED INTO MSP —URINALS 1.0 GPF11 —SHOWER HEADS 2.5 GPM HOUSE AERIAL VIEW: OCPD RATING 60 AMPS STRINGS WITH MODULES IN SERIES IN EACH INSTALLATION NOTES: STRINGING STRING THE PV BREAKER SHALL NOT EXCEED 120% OF THE ALLOWABLE BACK FEED OF THE MAIN UTILITY IMPERIAL IRRIGATION DISTRICT IID ( ) SERVICE BUSS RATING. i PV WIRE SHALL BE USED ON DC RUNS FOR UNGROUNDED/TRANSFORMERLESS TABLE OF CONTENTS PV-1 SITE LOCATION AND HOUSE AERIAL VIEW PV-2 SITE PLAN PV-2A ROOF PLAN WITH MODULES LAYOUT PV-3 ELECTRICAL LINE DIAGRAM PV-4 EXISTING SERVICE PANEL PV-5 ROOF MOUNTING DETAILS, ELEC. CALCULATION & MATERIAL LIST PV-6 LABELS PV-7 OPTIMIZER CHART PV-8 SAFETY PLAN INVERTERS. INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITS ARE ATTACHED TO THE ROOF USING PRESSURE TREATED WOOD IN CASE , OF COMPOSITE ROOF OR COUNDUIT HANGERS IN CASE OF CONCRETE ROOF DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE. ' RECEIVED_ FEB 12 2020 _ o CITY OF LA QUINTA O DESIGN AND DEVELOPMENT DEPARTMENT — MODULE LOCATION f Eiocinoe!Coni-dorNo: CLIENT: REVISIONS: TITLE SHEET: freedom 43 C-10#1029644 HANDLER, FRANCINE DATE: 11/04/2019 N DESCRIPTION DATE REVISION F 0 R F. V F R 47625 VIA MONTIGO, DESIGN GREG SITE LOCATION AND PV_1 v FREEDOM FOREVER LLC LA QUINTA, CA 92253 BY: O HOUSE AERIAL VIEW (916) 871-4703 1 � 43445 Business Park Dr Suite 110, Temecula, CA 92590 JOB ID.: F039574 l`` Tel: (800) 385-1075 J 4 IS; 91 r; I 25'-8" ~� 22'-7' EleCLIENT: freedom IC-10#11029644 F ::) R F V F R FREEDOM FOREVER LLC 43445 Business Park Dr Suite 110, Temecula, CA 92590 Tel.-(800) 385-1075 HANDLER, FRANCINE 47625 VIA MONTIGO, LA QUINTA, CA 92253 (916) 871-4703 f9PY/lC I lklC REVISIONS: DESCRIPTION DATE I REVISION ROOF AREA: 4623.15 SQ FT SITE PLAN 1 SCALE: 3/32" = 1'-0" DATE: 1 11 /04/2019 DESIGN BY: GREG JOB ID.: 1 F039574 TITLE: 1 SHEET: SITE PLAN I PV-2 NOTE: O EMT CONDUIT SUPPORTED BY PIPE HANGERS 12" TO 18" AWAY FROM ROOF EDGE Q ATTACH CLAMP AT 25% FROM EDGE AND 50% FROM CENTER OF MODULES 30 JUNCTION BOX MOUNTED TO THE RAIL LEGEND: ® CHIMNEY O PIPE VENT 2" X 4" TRUSSES @ 24" O.0 (TYP.) ^u'c�r,snca«w° CLIENT: . freedom C-10#1029644 F-"IRF VFF FREEDOM FOREVER LLC 43445 Business Park Or Suite 110, Temecula, CA 92590 Tel: (800) 385-1075 ROOF AREA STATEMENT ROOF MOQDU ES PITCH AZIMUTH ROOF AREA ARRAY AREA 1 39 1 19° 1 185° 11246.45 SQ FT 733.87 SQ FT 1. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans and accompanying calculations and notify the Engineer of Record of any discrepancies prior to starting construction, 2. These plans are stamped for structural code compliance of the roof framing supporting the proposed PV installation referenced only. These plans are not stamped for water leakage. 3. Please see accompanying Structural Calculations report for details regarding calculations as well as limits of scope of work and liability. 4. Attachments to be installed in a staggered orientation to properly distribute loads. STRUCTURAL ONLY (N) 39 LG335N1C-A5, 335W MODULES (N) ATTACHMENT POINTS @Q 72" O.C. MAX. f.CCESS NAYS DISCONNECT PANEL Digitally signed by Joshua Yacoby, PE Date: 2019.11.06 16:33:27-08'00' ROOF PLAN WITH MODULES LAYOUT 1 SCALE: 3/32" = V-0" REVISIONS: TITLE SHEET: HANDLER, F RAN C I N E DESCRIPTION DATE REVISION DATE: 11 /04/2019 47625 VIA MONTIGO, DESIGN GREG ROOF PLAN WITH PV-ZA LA QUINTA, CA 92253 BY: MODULES LAYOUT (916) 871-4703 JOB ID. F039574 Max. OCPD: TOTAL DC kW: 13.065 kW (200A Bus) * (1.2) = 240A Max Rating (120% of Bus) TOTAL AC kW: 10.000 kW PV Backfeed (60A) + Main Breaker (175A) = (235A <_ 240A) INTERACTIVE PV SYSTEM See 705.12 of 2016 CEC STRING-2 I � I 13 LG335N1C-A5, 335W MODULES I � I I I I I I I L--- I -- SOLAREDGE III P400 POWER I — OPTIMIZERS STRING-3 13 LG335N1C-A5, , 4 - #10 AWG, PV 335W MODULES WIRE(TYP.2) I JUNCTION I BOX I II I I SOLAREDGE P400 POWER I OPTIMIZERS j J TRING-1 3 LG335N1C-A5, 35W MODULES SOLAREDGE P400 POWER OPTIMIZERS AC /— RAPID SHUTDOWN SWITCH DC --------------- (N) INVERTER SOLAR EDGE SE1000OH-US [Sill 6 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT 2 - #10 AWG, PV WIRE Current oQRtJFESSr*�y�! 1 - #6 AWG IN FREE AIR OR `��opE MAN�hq #8 AWG MUST BE IN EMT Engineering CONDUIT a E Email: Projects;)ctirrentrcnenm 012 ablcscng.co* No. No. Exp:E 22220121 General Notes : Website: currentreneisableseng.com P. (951).254.5655 FCiFtICA~• 1. (39) LG335N1C-A5, 335W MODULES wired and listed to UL1703 standards qTE 0F TIR\ CAO 2. SOLAR EDGE SE1000OH-US [Sill Inverter with integrated DC Disconnect and Arc Fault Protection. Attached with system electrical specifications and ground fault protected & listed to UL1741 standards. 3. Photovoltaic system ground will be tied into existing ground at main service from DC Disconnect/Inverter as per 2016 CEC Sec. 250.166(A). "The Grounding Electrode Conductor shall not be smaller than the neutral conductor and not smaller than 8AWG copper." 4. Equipment operating 150 volts or greater shall only be serviced or replaced by qualified personnel. Field protection may be in the form of conduit, closed cabinet or an enclosure which requires use of tools to open. 5. Solar Photovoltaic System equipment will be installed in accordance with requirements of Art. 690 of the 2016 CEC. 6.Minimum height of conduit above roof to match temperature derating factor. 7.Photovoltaic DC conductors entering the building shall be installed in metallic raceway and shall be identified every 10 feet -- and within 1 foot above and below penetrations of roof/ceiling assemblies, walls, or barriers -- with minimum 3/8-inch-high white lettering on red background reading: "WARN ING: PHOTOVOLTAIC POWER SOURCE" E111W 1C,"I,,lurNo: CLIENT: C-10#1029644 freedom F :+ k F V F R FREEDOM FOREVER LLC 43445 Business Paris Dr Suite 110, Temecula, CA 92590 Tel: (800) 385-1075 HANDLER, FRANCINE 47625 VIA MONTIGO, LA QUINTA, CA 92253 (916) 871-4703 Digitally signed by Methode Maniraguha, PE (E) 100A SUB (E) 200A MAIN PANEL SERVICE PANEL SINGLE PHASE / 240V / 60 HZ (E) 50A / 2P RELOCATED SUB PANEL LOADS BREAKER EXISTING ' CONDUIT AND WIRE • (N) 60A, AC DISCONNECT SQUARE D DU222RB NEMA 3R UL LISTED o 0 (N) DERATED 175A / 2P MAIN BREAKER (CENTER FED) (N) 60A / 2P PV BREAKER 3 - # AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT `l rDate: 2020.02.10 - CONNECT TO EXISTING UFER B.00:20-08�00� 8- System Grounding Electrode conductor for PV system to be sized to meet the requirements of CEC 2016 table 250.66, not smaller than #8 CU AWG." 9. If the existing main service panel does not have a ground rod or ufer, it is the pv contractors responsibility install one. 10. Smoke alarms and carbon monoxide detectors will meet the necessary requirements per CRC R314, R315 11. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM. 12.Terminals of the disconnecting means may be energized in the open position. 13. A signage labeled "SOLAR LOADS ONLY" is to be installed on dedicated solar sub panel to be used for PV only. 14. Solaredge inverters are listed to UL1741 and UL1699B standards. 15. Solaredge Optimizers are listed to IEC62109-1 (class II safety) and UL1741 standards. 16. PV system is using continuous grounding method with #6 bare copper wire. 17. Conduit and conductor specifications are based on minimum code requirements and are not meant to limit up -sizing as required by field conditions REVISIONS: DESCRIPTION DATE I REVISION TITLE: DATE: 11/04/2019 DESIGN GREG ELECTRICAL BY: LINE DIAGRAM (E) UTILITY METER SHEET: PV-3 JOB ID.: I F039574 (200A Bus) " (1.2) = 240A Max Rating (120% of Bus) PV Backfeed (60A) + Main Breaker (175A) = (235A <_ 240A) See 705.12 of 2016 CEC SOLAREDGE P400 POWER OPTIMIZERS SOLAREDGE P400 POWER OPTIMIZERS r--- RTRINr; 9 13 LG335N 1 C-A5, 335W MODULES STRINr; R 13 LG335N1C-A5, 335W MODULES C 2 - #10 AWG, PV WIRE 1 - #6 AWG IN FREE AIR OR #8 AWG MUST BE IN EMT CONDUIT General Notes : TOTAL DC kW: 13.065 kW TOTAL AC kW: 10.000 kW INTERACTIVE PV SYSTEM JUNCTION BOX TRING-1 3 LG335N 1 C-A5, 35W MODULES SOLAREDGE P400 POWER OPTIMIZERS AC /_ RAPID SHUTDOWN SWITCH 4 - #10 AWG, PV WIRE(TYP.2) u (N) INVERTER SOLAR EDGE SE1000OH-US [Sill 6 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT Current �' Engineering Email: Projects*currentrene;vableseng.e Website: currentrene;sableseng.com P.(951).254.5655 (39) LG335N1C-A5, 335W MODULES wired and listed to UL1703 standards c No. E 22012 * Exp:09/30/21 grf�FCAL1 2. SOLAR EDGE SE10000H-US [Sill Inverter with integrated DC Disconnect and Arc Fault Protection. Attached with system electrical specifications and ground fault protected & listed to UL1741 standards. 3. Photovoltaic system ground will be tied into existing ground at main service from DC Disconnect/Inverter as per 2016 CEC Sec. 250.166(A). "The Grounding Electrode Conductor shall not be smaller than the neutral conductor and not smaller than 8AWG copper." 4. Equipment operating 150 volts or greater shall only be serviced or replaced by qualified personnel. Field protection may be in the form of conduit, closed cabinet or an enclosure which requires use of tools to open. 5. Solar Photovoltaic System equipment will be installed in accordance with requirements of Art. 690 of the 2016 CEC. 6.Minimum height of conduit above roof to match temperature derating factor. 7.Photovoltaic DC conductors entering the building shall be installed in metallic raceway and shall be identified every 10 feet -- and within 1 foot above and below penetrations of roof/ceiling assemblies, walls, or barriers -- with minimum 3/8-inch-high white lettering on red background reading: "WARN ING: PHOTOVOLTAIC POWER SOURCE" -—I conU-WNn. CLIENT: ���, r0r�.:1 . •.freedom C-l0#1029644 FREEDOM FOREVER RLLC 43445 Business Park Dr Suite 110, Temecula, CA 92590 Tel: (800) 385-1075 HANDLER, FRANCINE 47625 VIA MONTIGO, LA QUINTA, CA 92253 (916) 871-4703 Digitally signed by Methode Maniraguha, PE Date: 2020.02.10 08:00:30-08'00' (E) 100A SUB (E) 200A MAIN PANEL SERVICE PANEL SINGLE PHASE / 240V / 60 HZ (E) 50A / 2P RELOCATED SUB PANEL LOADS •�• BREAKER EXISTING CONDUIT AND • WIRE (N) 60A, AC •��• DISCONNECT SQUARE D (N) DERATED 175A / 2P DU222RB MAIN BREAKER (CENTER FED) NEMA 3R UL LISTED (N) 60A / 2P PV i • BREAKER , JI 0 3 - # AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT - CONNECT TO EXISTING UFER *9.System Grounding Electrode conductor for PV system to be sized to meet the requirements of CEC 2016 table 250.66, not smaller than #8 CU AWG." 9. If the existing main service panel does not have a ground rod or ufer, it is the pv contractors responsibility install one. 10. Smoke alarms and carbon monoxide detectors will meet the necessary requirements per CRC R314, R315 11. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM. 12.Terminals of the disconnecting means may be energized in the open position. 13. A signage labeled "SOLAR LOADS ONLY" is to be installed on dedicated solar sub panel to be used for PV only. 14. Solaredge inverters are listed to UL1741 and UL1699B standards. 15. Solaredge Optimizers are listed to IEC62109-1 (class II safety) and UL1741 standards. 16. PV system is using continuous grounding method with #6 bare copper wire. 17. Conduit and conductor specifications are based on minimum code requirements and are not meant to limit up -sizing as required by field conditions REVISIONS: DESCRIPTION I DATE I REVISION DATE: 11 /04/2019 TITLE: DESIGN BY: GREG ELECTRICAL SINGLE LINE DIAGRAM (E) UTILITY METER SHEET: PV-3A JOB ID.: I F039574 Leomcal contractor No CLIENT: �' ti"'• freedom i C-10#1029644 fOREVFR �.; FREEDOM FOREVER LLC 43445 Business Park Dr Suite 110, Temecula, CA 92590 Tel: (800) 385-1075 HANDLER, FRANCINE 47625 VIA MONTIGO, LA QUINTA, CA 92253 (916) 871-4703 REVISIONS: DESCRIPTION N. i oQRo�Essr�Nq� `�4�00� MAN�RgG�yy No. E 22012 k Exp:09/30121 st�ECTR�G��. �TF of CA Digitally signed by Methode Maniraguha, PE Date: 2020.02.10 08:00:40-08'00' 1 DATE: 11 /04/2019 TITLE: SHEET DATE REVISION DESIGN BY: I GREG JOB ID,: I F039574 EXISTING I PV-4 SERVICE PANEL ELECTRICAL CALCULATIONS MATERIAL LIST PV MODULES, BY OTHERS UNIRAC LIGHT RAIL -- BACKFEED BREAKER SIZING (E) FLAT TILE MAX. CONTINUOUS OUTPUT 42A @ 240V 42 X 1.25 = 52.50AMPS 60A BREAKER - OK UNIRAC SOLAR HOOK TYP 2016 CEC 705.12 SUB FLASHING 200 X 1.20 = 240 (OPTIONAL) 240 - 175 = 65A ALLOWABLE BACKFEED (E) BUILDING 5/16"x3.5" SS LAG BOLT WITH DE -RATED AMPACITY OF 6AWG CONDUCTOR @ 0.82 STRUCTURE MIN 2Y2" THREAD EMBEDMENT, TEMPERATURE CORRECTION SEALED PENETRATION 75 X 0.82 = 61.50 AMPS - OK PV MODULES, BY OTHERS UNIRAC LIGHT RAIL (E) FLAT TILE UNIRAC SOLAR HOOK SUB FLASHING (OPTIONAL) (E) BUILDING 5/16"x3.5" SS LAG BOLT WITH STRUCTURE MIN 2%2' THREAD EMBEDMENT, SUB FLASHING SEALED PENETRATION (OPTIONAL) UNIRAC LIGHT RAIL UNIRAC SOLAR HOOK TYP QTY EQUIPMENT DESCRIPTION OPEN CIRCUIT VOLTAGE (Voc) : 41.OV MAX. POWER VOLTAGE (Vmp): 34.1V 39 LG335N1C-A5, SHORT CIRCUIT CURRENT (Isc): 10.49A 335W MODULES MAX. POWER CURRENT (Imp) : 9.83A PTC RATING: 311.1W MAX. DC INPUT VOLTAGE : 480V SOLAR EDGE MAX. AC OUTPUT VOLTAGE RANGE: 211-240V 1 SE1000OH-US MAX. AC OUTPUT CURRENT : 42A [S11] MAX. AC POWER OUPUT: 10000W CEC EFFICIENCY : 99% RATED DC INPUT POWER: 400V SOLAR EDGE MAXIMUM INPUT VOLTAGE: 48Vdc 39 P400 POWER MPPT RANGE: 8 - 80Vdc OPTIMIZERS MAX. INPUT CURRENT: 13.75Adc MAX. OUTPUT CURRENT: 15Adc 1 JUNCTION BOX 60OVDC, NEMA 3R, UL LISTED 1 AC DISCONNECT 240VAC, 60A, NEMA 3R, UL LISTED 1 PV BREAKER 2 POLE, 240V, 60A 62 ATTACHMENTS FLAT TILE HOOK 250' RAIL UNIRAC LIGHT RAIL UNIRAC LIGHT RAIL GROUNDING 68 MID CLAMPS MID CLAMPS 20 END CLAMPS UNIRAC LIGHT RAIL END CLAMPS 40' CONDUIT 3/4" OR LARGER EMT CONDUIT (E) FLAT TILE y¢�FSSSY�0 Digitally signed i 1{ „ by Joshua YY 0. 86065 m Ya co b P E Or �Sf o * Exp.9130/2020 * y, QQ� A� Digitally signed 2" X 4" TRUSSES @ �rf c/V06 ti� Date: 2019.11.06°� �N� 9 `� 24" O.0 �f7pFCp% 16:33:16 -0800 �G ti y Methode STRUCTURAL ONLY No t % aniraguha, PE * Exp:09/30/21 * ate: 2020.02.1 0 ti 1, Prior to commencement of work, the contractor shall verify the framing sizes, spacings, +�rr ECTR'C �Q�4 08 :00,5 2 -08 t DDr and spans noted n the stamped plans and accompanying calculations and notify the S �� � Photovoltaic Panel Mounting Detail Engineer of Record of any discrepancies prior to starting construction. l� 2. These plans are stamped for structural code compliance of the roof framing supporting Scale: NTS the proposed PV installation referenced only. These plans are not stamped for water leakage. 3; Please see accompanying Structural Calculations report for details regarding calculations as well as limits of scope of work and liability. d Attachments to be installed in a staggered orientation to properly distribute loads. Ell--IcontractorNI: CLIENT: REVISIONS: TITLE: SHEET: freedom C-10#1029644 HANDLER, FRANCINE DATE: 11/04/2019 ROOF MOUNTING DESCRIPTION DATE REVISION f n R F V F R 47625 VIA MONTIGO, DESIGN GREG DETAILS, ELEC. PV-5 FREEDOM FOREVER LLC LA QUINTA, CA 92253 BY: CALCULATION & 43445 Business Park Dr Suite 110, Temecula, CA 92590 (916) 871-4703 MATERIAL LIST Jog ID.: F039574 Tel: (800) 385-1075 "WARNING" INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE (UNLESS BUSBAR IS FULLY RATED) 705.12(D)(2) I I I I PHOTOVOLTAIC SYSTEM, EQUIPPED WITH RAPID SHUTDOWN 690.12 "WARNING" ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. 690.35(F) ARRAY lm� 0 C w w z I J/B DC - AI I fl CEC 690.31(G)(3) & (4), CRC R324.7 I II "WARNING" PHOTOVOLTIC POWER SOURCE f J L EVERY 1U ON COUNDUIT AND ENCLOSURES EkdrlcalConyecmrNo: CLIENT: freedF 0om C-10#1029644 FREEDOM FOREVER LLC 43445 Business Park Dr Suite 110, Temecula, CA 92590 Tel: (800) 385-1075 "WARNING" DUAL POWER SOURCES SECOND SOURCE IS PHOTO- VOLTAIC SYSTEM RATED AC OUTPUT CURRENT - 42 AMPS AC NORMAL OPERATING VOLTAGE - 240 VOLTS 690.54 PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT - 42 AMPS AC NORMAL OPERATING VOLTAGE - 240 VOLTS 690.14, 690.15, 690.54 "WARNING" ELECTRIC SHOCK HAZARD IF A GROUND- FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. 690.5(C) DIRECT CURRENT PHOTOVOLTAIC POWER SOURCE MAXIMUM VOLTAGE - 240 VDC MAX CIRCUIT CURRENT - 42 AMPS "WARNING" ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. 690.17 PV SYSTEM DC DISCONNECT OPERATING CURRENT: 32.66A OPERATING VOLTAGE: 400.00V SHORT-CIRCUIT CURRENT: 45.00A MAX SYSTEM VOLTAGE: 480.00V 690.14(CO(2)), 690.15, 690.53 HANDLER, FRANCINE 47625 VIA MONTIGO, LA QUINTA, CA 92253 (916) 871-4703 NOTES: 1. CEC ARTICLES 690 AND 705 AND CRC SECTION R324 MARKINGS SHOWN HEREON 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SING MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK C. ARIAL FONT 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT POP -RIVETS OR SCREWS. CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS SHOWN. DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES Q�OFESS1,9 ANiRG��y o cc No. E 22012 ao * Exp:09/30/21 'rr CTR\'- �lFOf CAEIF�� ® a 0 0 Digitally signed Methode Manira uha, 0 PE Date: 2020.02.1 ® 08:01:03-08'00' D o 0 Z ® 0 -i c� 0 0 O 0 000 00 n 39 PV MODULE JUNCTION BOX AC DISCONNECT INVERTER EQUIPPED SUB PANEL WITH RAPID SHUTDOWN MAIN SERVICE PANEL 6X8" TYP - CEC 705.10 REVISIONS: DESCRIPTION I DATE I REVISION DATE: 1 11 /04/2019 DESIGN BY: I GREG JOB ID.: I F039574 TITLE: I SHEET: LABELS I PV-6 1-10 11-20 21-30 31-40 41-50 51-60 1 2 3 5 on 7 0 0 10 �"°""�'°ci0 "° CLIENT: REVISIONS: TITLE SHEET: PI -I f� C-10#i029644 DATE: 11/04/2019 freedom HANDLER, FRANCINE DESCRIPTION DATE REVISION F 0 R F, V F R 47625 VIA MONTIGO, DESIGN GREG OPTIMIZER PV-7 FREEDOM FOREVER LLC LA QUINTA, CA 92253 CHART 43445 Business Park Dr Suite 110, Temecula, CA 92590 (916) 871-4703 JOB ID.: F039574 Tel: (800) 385-1075 CREW SIGNATURES: MEDICAL INFORMATION: 0 0 Z 0 Q PPE INFORMATION HAZARDS SAFETY PLAN SCALE: NTS 1 _ EI-16-1 C-1,11*, N.:CLIENT: C-10#1029644 �freedom F n R r v f h FREEDOM FOREVER LLC HANDLER, FRANCINE 47625 VIA MONTIGO, LA QUINTA, CA 92253 (916) 871-4703 REVISIONS: DATE' 11/04/2019 TITLE SAFETY PLAN SHEET: P\/_Q v U DESCRIPTION DATE REVISION DESIGN BY: GREG 43445 Business Park Dr Suite 110. Temecula, CA 92590 Tel: (800) 385-1075 log ID. F039574 CD CA CD CD cn CD CD K c O � o � N N O m n c 0 a ❑ ❑ ❑ ❑ ❑ (D C .. O 0 0 0 0 0 � O r O Z O a Li m m O R R R o o a p p 7 Z N O (D ♦ ♦ 4 1 C CO) o ❑ ❑ ❑ ❑ ❑ v CL N A N A N A N A N A O O O O O ❑��oo� vcn zc» r O O N C� (D m (D o�' C o 7.0 N 7 y (D C D (D ro ro W O C TI (D S r. CT7 < N O Q �° o ° n m ��♦ ° CD c m a O O O O O O A A A Z D O O O D D o ❑a ❑ qq x O n m w m m z w♦ ♦♦♦♦ a N 4 c 0 3 M D � 0 70 n ti ��� m D s s � mm m �v, � M � �� T y � O -D U a'� � n rNw � 8n A � 8A O < < O O C < O O O S D b D D n a a n n n n a ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ LG Life's Good LG. LGa3SN1C-AS LG's new module, LG NeONTm 2, adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires cell" enhance power output and reliability. LG NeCINT"' 2 demonstrates LG's efforts to increase customer's values beyond efficiency. It features enhanced warranty, durability, performance under real environment, and aesthetic design suitable for roofs. Enhanced Performance Warranty LG NeONI 2 has an enhanced performance warranty. The annual degradation has fallen from-0.6%/yrto -0.55%/yr. Even after 25 years, the cell guarantees 1.2%p more output than the previous LG NeONT"" 2 modules. Aesthetic Roof LG NeONT 2 has been designed with aesthetics in mind; thinner wires that appear all black at a distance. The product may help increase the value of a property with its modern design. .�.: Better Performance on a Sunny Day LG NeCINT'" 2 now performs better on sunny days thanks to its improved temperature coefficiency. About LG Electronics om us C E Intertek s drums,: High Power Output 1;ff Compared with previous models, the LG NeCINT14 2 has been designed to significantly enhance its output efficiency, thereby making it efficient even in limited space. Outstanding Durability With its newly reinforced frame design, LG has extended the warranty of the LG NeONTM 2 for an additional 2 years. Additionally, LG NeCINT' 2 can endure a front load up to 6000 Pa, and a rear load up to 5400 Pa. Double -Sided Cell Structure The rear of the cell used in LG NeCINT°" 2 will contribute to generation, just like the front; the light beam reflected from the rear of the module is reabsorbed to generate a great amount of additional power. LG Electronics is a global player who has been committed to expanding its capacity, based on solar energy business as its future growth engine. We embarked on a solar energy source research program in 1985, supported by LG Group's rich experience in semi -conductor, LCD, chemistry, and materials industry. We successfully released the first Mono X10 series to the market in 2010, which were exported to 32 countries in the following 2 years, thereafter. In 2013, LG NeCINTM (previously known as Mono X* NeON) won "Intersolar Award", which proved LG is the leader of innovation in the industry. LG NeON z Mechanical Properties Cells L6335N1 C•R5 Cell Tme iy onocrystalune / N-type Cell Dimensions 161.7 x 161.7 mm / 6 inches s of Busbar Dimensions (L x W x H) Front Load Rear Load 12 (Multi Wire Busbar) 1686 x 1016 x 40 cam 66.38 x 40 x 1.57 inch 6000Pa 5400Pa Weight 18 kg Connector Type MC4 Junction Box IP68 with 3 Bypass Diodes Cables Glass Frame Certifications and Warranty Certifications 1000 mm x 2 ea High Transmission Tempered Glass Anodized Aluminium IEC 61215, IEC 61730-1 /-2 UL1703 IEC 61701 (Salt mist corrosion test) IEC 62716 (Ammonia corrosion test) 1509001 Module Fire Performance (USA) Type 1 Fire Rating (CANADA) Class C (ULC / ORD C1703) Product Warranty 12 years Output Warranty of Pmax Linear warranty" " 1) 1st year 98%, 2) After 211d year:0 55%annual degradation, 3) 25 years: 84.8% Temperature Characteristics NOCT Pmpp Voc Isc Characteristic Curves 10 � s u 4 2 45t3°C -0.37%/°C -0.27%/°C 0.03 %/°C 100DWV 0 1 13 is 20 25 30 rs 40 140 ..... .... .. .. .._— _..—_. .. m120 ............... ... .. .. ..-----....... ..... ..... aisc 0 100................_.-.�-- a0 2J LG North America Solar Business Team OLG Electronics USA Inc Life's Good 1000 Sylvan Ave, Englewood Cliffs, NJ 07632 Contact: Ig.solar@0 Ige m m wwwlgsolarusacom larag°M Electrical Properties (STC *) Module LG33SN1 c-A5 Maximum Power (Pmax) 335 MPP Volage (Vmpp) 34.1 MPP Current (Impp) 9.83 Open Circuit Voltage (Voc) 41.0 Short Circuit Current (Isc) 10.49 Module Efficiency 19.6 Operating Temperature -40 - +90 i Maximum System Voltage 1,000 Maximum Series Fuse Rating 20 Power Tolerance (%) 0 - +3 STC (Standard Test Condidon); Irradiance 1,000 Wei, , Ambient Temperature 25 °C, AM 15 • The narreplate power output Is measured and detem,lned by LG Electmnlm at Its sole and absolute dlsvetion The Typical change in module efficiency at 200W/m2 in relation to 1000W/m2 is -2.096 Electrical Properties (NOCT*) Module LG335N1 C-AS Maximum Power (Pmax) 247 MPP Voltage (Vm ) 31.5 MPP Current (Impp) 7.63 Open Circuit Voltage (Voc) 38.2 Short circuit Current (lac) 8.44 * NOCT (Nominal Operating cell Tempeaatur ay Imadiarax BOOW/m', ambient temperature 20 °C, wind speed 1 m/s Dimensions (mm/in) — T-Paarun: re) W Product specifications are subject to change without notice. Copyright ® 2017 LG Electronim. All rights reserved 01/01/2017 7 .18� Innovation for a Better Life Z Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US / SE1000OH-US / SE1140OH-US rl 2 -_2 51 I to aalar yrl L ! i[7 • ANTN 0 Rnlar,f . h� ® i rrrr •000 a • .. M ■ IF • o Optimized installation with HD -Wave technology / Specifically designed to work with / Extremely small power optimizers / Record -breaking efficiency / Built-in module -level monitoring / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for / Optional: Revenue grade data, ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5% accuracy) / UL1741 SA certified, for CPUC Rule 21 grid compliance solaredge.com solar- ■• z 1 Single Phase Inverter with HD -Wave Techn❑ Ogg/ for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US •O OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @240V 10000 @ 208V VA AC Output Voltage Min--Nom.-Max ✓ ✓ ✓ ✓ ✓ ✓ Vac (211 - 240 - 264) AC Output Voltage Min.-Nom.-Max ✓ _ ✓ ✓ Vac (183 - 208 229) AC Frequency (Nominal) 59-3 - 60 - 60.50) Hz Maximum Continuous Output 12,5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output _ 16 _ 24 485 A Current @208V _ GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Yes I hresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 77SO 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240Vi'l 8.5 10.5 1 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208Vizl 9 - 13.5 27 45 Adc Adc Max. Input Short Circuit Current Reverse -Polarity Protection `es Ground -Fault Isolation Detection 600ku Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V % 98.5 @ 208V Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces Revenue Grade Data, ANSI C1220 Rapid Shutdown - NEC 2014 and 2017 690.12 STANDARD COMPLIANCE Safety Grid Connection Standards Emissions RS48S, Ethernet, ZigBee (optional), Cellular (optional) Optional"' Automatic Rapid Shutdown upon AC Grid Disconnect UL1741, UL1741 SA, UL169913, CSA C22.2, Canadian AFCI according to TLL M-07 IEEE1547, Rule 21, Rule 14 (HI) FCC Part 15 Class 8 INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 3/4" minimum / 14-6 AWG 3/4• minimum /14-4 AWG DC Input Conduit Size / # of Strings AWG Rartge / 3/4" minimum / 1-2 strings / 14-6 AWG 3/4• minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HXW AP) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22110 25.1 / 11A 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -25 to +600) (-40°F / -40"C option)() 7 / `C Protection Rating NEMA 4X (Inverter with Safety Switch) 0' For other regional settings please comact SDldrkdge support (',A higher current source maybe used; the inWiW will limit its input current to the values stated Revenue grade inverter P/N: SExxxxH-USMONNC2 For power de -rating information refer to: hm;w/Awwsolaredge.com/sites/defaulVfiles/se-temperature-derating-note-na.pdf -40 version P/N: SEx H-USOOONNU4 C, SolarEdge Technologies, Inc All rights reserved SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc All other trademarks mentioned herein are trademarks of their respective owners. Date. 12/2016/VO1/ENG NAM, Subject to change without notice. RoH S Power Optirinizer For North America P320 / P340 / P370 / P400 / P405 / P505 25 YEAR WARRANTY 1 PV power optimization at the module -level / Specifically designed to work with SolarEdge inverters / Up to 25% more energy Superior efficiency (99.5%) / Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading / Flexible system design for maximum space utilization solaredge.com I Fast installation with a single bolt Next generation maintenance with module - level monitoring / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) r/ Module -level voltage shutdown for installer and firefighter safety solar=@o 1 Power optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 HIM11j11 Rated Input DC Powe,hs 320 1 340 370 400 405 505 W Absolute Maximum Input Voltage 48 60 80 125(1) 830 Vdc (Vol: at lowest tenperaaare) MPPT Operating Range. 8 - 48 8 - 60 8 - 80 12,5 -105 12.5 - 83 Vdc Maximum Short Circuit Current 11 10.1 14 Adc FsU Maximum DC Input Current 13.75 12 63 17.5 Adc Maximum Hkiero 99.5 % WeightedEfflcieTcy 98.8 986 % overvdlage Catggry 0. OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Outpgl Current 15 1 Adc Maximum output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OF Safety Output Voltage per 1 t 0.1 Vdc STANDARD COMPLIANCE EMC Safety ROHS INSTALLATION SPECIFICATIONS FCC Part15 Class 8, IEC61000-6-2, IEC61000-6-3 IEC62109-1 (class II safety), UL1741 Yes Maximum Allowed System 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(WxLxH) 129x153x27.5/5.1x6x1.1 129x153x33.5/ 5.1x6x13 129x159x49.5/ 5.1x6.3x%9 129x162x59/ 5.1x6.4x2.3 rem/in ► tlghl (imlld irg tables) 630 / 1.4 7S0 / 1.7 845 / 1-9 1064 / 2.3 .7 / lb Input Connector MC4r1) oviout Wire Type / Connector Double Insulated; MC4 Output Wire Length 0.95 / 3.0 1.213.9 m / ft Input Wire Lepxp 0,16 / 0 52 m / ft Operathlg Temperalwe Rary -40 - +85 / -40 - 4185 "C / "F Protection Rating Relative kumldlty IP68 / NEMA6P _ 0 - 100 % Rated STC powe- of the module. Module of up to .5% power tolerance allowed NEC 2017 requires max input voltage be not more than 80V For other conne_tor types please contact SolarEdge Minimum String Length P320, P340, P370,P400 8 10 8 (Power Optimizers) P405 / P505 6 B 14 Maximum String Length 25 25 SON (Power 01%0101A 5700 (6000 with Maximum Power per String SE7600-US - SE11400- 5250 US) Parallel Strings of iElftent Len9ft or Orientations Yes 6000r0 1 127501a1 1 W "' For detailed strirg sizing information refer to: httpl/mn v.sulamdge.corn/sites/defaulVfiles/5tring_si7ing na.pdf It is not allowed to mix P405/1`505 with P320/P34C/P370/P400 in one string ' A string with me e than 30 optimizers does not meet NEC rapid shutduwn requirements; safety vo!Lage will be above the 30V requirement r'For SE14.4KUS/5E43,2KUS: It is allowed to install up to 6,50DW per string when 3 strings are connected to the inverter (3 strings per unit for SE43.21<U5) and when the maximum power difference between the strings is up to 1,000W "- For SE30KUS/SE33,3KU5/SE66.6KUS/5E100KUS: It is allowed to install up to 1S,000W per string when 3 strings are connected to the inverter (3 strings per unit for SE66.6Kt1S/SE100KUS) and when the maximum power difference between the ;trings is up to 2.000W ® SolarEdge Technolcgies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPT[MQED BY SOLAREDGE are trademark or registered trademarks of SolarEdge T hnologias, me E RoH S All other trademarks nernfoned herein are trademarks of thelr respective mvners. Date:17J2018/V01/ENG NAM Subject to change without notice June 20, 2014 3933 US Route 11 Cortland, NY 13045 Telephone: (607) 753-6711 Facsimile: (607) 756-9891 www.intertek.com Letter Report No. 101703554CRT-001 Project No. G101703554 Mr. Meir Adest Ph: +972.9.957.6620 SolarEdge Technologies Ltd email: meir.a@solaredge.com 6 Ha'Harash St. HOD HASHARON, ISRAEL Subject: ETL Evaluation of SolarEdge Products to NEC Rapid Shutdown Requirements Dear Mr. Meir Adest, This letter represents the testing results of the below listed products to the requirements contained in the following standards: National Electric Code, 2014, Section 690.12 requirement for rapid shutdown. This investigation was authorized by signed Quote 500534459 dated 06/10/2014. Rapid shutdown test were perform at SolarEdge Technologies Ltd, 6 Ha'Harash St HOD HASHARON, ISRAEL and witness by Intertek personal on 06/17/2014. The evaluation covers installations consisting of optimizers and inverters with part numbers listed below. The testing done has verified that controlled conductors are limited to not more than 30 volts and 240 volt- amperes within 10 seconds of rapid shutdown initiation. Applicable products: • Power optimizers: o PBxxx-yyy-zzzz; where xxx is any number, 0-9, up to a maximum value where xxx = 350; yyy could be AOB or TFI; and zzzz is any combination of four letters and numbers. o OP-XXX-LV, OP-XXX-MV, OP-XXX-IV, OP-XXX-EV; where xxx is any number, 0-9. o Paaa, Pbbb, Pccc, Pddd, Peee; where aaa, bbb, ccc, ddd, eee is any number, 0-9 to a maximum upto aaa=300, bbb=350 ccc=500, ddd=600, eee=700. o Pxxx, Pyyy, Pzzz, Pmmm, Pnnn and P000; where xxx, yyy, zzz is any number, 0-9 to a maximum up to xxx=300, yyy=350, zzz=500; where mmm, nnn, 000 is any number, 0-9 to a maximum up to mmm=405, nnn=300, 000=350 1-ph Inverters: o SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE1140OA-US when the SolarEdge rapid shutdown cable labeled "MCI-CB-xxxxx-x" which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is any number; inverter part number may be followed by a suffix Page 1 of 2 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Interiek's responsibility and liability are limited to the terms and conditions of the agreement Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek The observations and test results In this report are relevant only the sample tested. This report by itself does not imply that the material, product or service is or has ever been under an Inlarlek certification program 015/(i�) O aent3l llntert••s: GS n Intertek Intertek Intertek fntertek IntefYek Intertek SolarEdge Technologies Ltd • 3-ph Inverters: Letter Report 101703554CRT-001 June 201h, 2014 o SE9KUS / SE10KUS / SE20KUS when the SolarEdge rapid shutdown cable labeled "MCI-CB-xxxxx- x" which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is any number; inverter part number may be followed by a suffix This letter report completes this portion of the evaluation covered by Intertek Project No.113101703554, If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the undersigned. Please note, this Letter Report does not represent authorization for the use of any Intertek certification marks. Completed by: Radhe Patel Reviewed by: Howard Liu Title: Engineering Team Lead Title: Staff Engineer Signature:CI?. Signature Date June 20 , 2014 Date: June 207 2 114 Intertek Testing Services NA, Inc. Page 2 of 2 So 12,1.2 (11/11/10) Informative Intertek Testing Services NA, Inc. SD 12.1.2 (11111/10) Informative OPTIONAL FRONT TRIM !otl SOLARMOUNT BETTER DESIGNS TRUST THE INDUSTRY'S BEST DESIGN TOOL Start the design plocess foi evcly ;;nIII-0 In nul 11 fllllllh'I uu Link 11w,lgll I ll-I It's a Meat way to save time and nlunr,v BETTER SSTE ,' S ONE SYSTEM - MANY APPLICATIONS Oulckly set lnodnles Hush to the 1 I1001l:,.f iml., +.11lclli ;up,e �mlillq of modules In Poltlalt m Landscau I I v�,lnnl op )II Hill ul iuv, into luol:, omponents available m mill, clear. ul,, 1 Or hrs: to npulmn void Ilwo rnlmwl;as Ind aesthetics BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB (lost Unlfar, to help Vol] nunimlzn bush .4 •Irui ,nld I;;unl ,w I Ilool Illy Linn: 1111;004 quolcrl to the Lune ynlu (IIRel ulI Iloueul l,li lcl nr,iall,. i.lnla f'loillr IFUNIRAC B ETT :R SUPPORT 25 WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Plole,sslonal soppoll Im prolcssnlll,l: ulr. 01: �m1l �ilc,,pucl; '+un tlnvl �I,:r,l^., n YEAR ell[ leehlllcal mippolI and tialnlll j;IiIIInG dl�h;ilevcl yell) "iiijtmll ilCPll' ,trve gill yaucoveled visitUnilac.com/solalfiuloIII rw.1ml,iuinl1nnllae flkcsi5: 41l11flHANIY 9 Lu o III Itll IIhJI; . ill Iill.11'�Il gfdl � UL2703 N,I i;l IAfJh'AI I I IItU11Jl �4 "'Y., I I h, I ki CLA3 dl 1I'lII II IN eUNIRAC CONCEALED UNIVERSAL ENDCLAMPS cy - .1 UNIVERSAL SEI.F STANDING MIOCLAMPS END CAPS INCLUDED WITH EVERY ENDCLAMP U-BUILDER ONLINE DESIGN TOO[ SAVES TIME & MONEY 'll::,s irs,ll ,I I UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT 'ENOCLAMPS NNNAICHED I: RIN11N ING1111t111t1G ISANKARII orsu.l r End CAPS EXPERIENCE Ip1Rl it Y I KIM 1i HCt v NRA':11 Y UIIL'lllll 211UN THE PROFESSIONALS' CHOICE FOR RESIDENTIAL RACKING i,1iiiii'1,­ ...... .iP,..i .. ... . ...... .. , . I , I..,,,. iit•„ii,lii,11111111 i,i, It., i l l i l i. , .,,lI i I r, .li„ii•i 11'. ii lil.ii BEST INSTALLATION EXPERIENCE -CURB APPEAL -COMPLETE SOLUTION - UNIRAC SUPPORT TECHNICAL SUPPORT Unuacs I(doocal soppInl lcaln Is dedo;iocc Ill �o;svlr,tnil, queshons R. arldressmg issues in IC:Ii lirre ? i� •udllw ihlary of dnerinicool Including popoir-niliniv 4omts. stamperl Icum and lcchmcal cm,- hnrl: .ur,nllM simpllhcs your pennilhn', and ploleri pimiiii l ,your;: CERTIFIED QUALITY PROVIDER thuuic;., Ir.oIIIY�!'l'rnuunllll}; vl,luiul'N�IIPI IRII �; �Ilhctlluur; ?m luill?I n l lilllll.'I'IUr. dmi illf:"Af INlilll,'llfli dIIIiP.II rolmr: Nl: mdivfil lhfr hiRIiIISI Shlndllld5 Qr III. :'trcllrnrr tun+, u mill ilr'll lu ill -it mllz, bo;lnr:,5 n w1r:1:, BANKABLE WARRANTY Ilulli llr ve ynol nnne,:i lit eiculro, ILnlnc Yrvf Ilu1 Ilntmnia �hlrp! i 'ii IYic� -Ili: 711101111 IIII c110Ci mil{ iC,h Ilad9 pl'iitH n1 'hill kll!n°NII;? 'iiw III igo'!I!ilit' ilflidllcl6 ill cx�.:cphl�nai ooahly SII00111Illcl r :uvelall :ly !",; "La, hlllll!"l I!I IIIIIII v!;nGlliil' 11111: ,'i:�l '!II III I'[. 11f11'Cb 5'r; ll l!llly ENHANCE YOUR REPIITATION� I-`.. i,Wr ,1, ! I;?stt11 ��, t+.l;l Iy..rNl�l`f�1r SOLARHOOKS Ljj r."UNIRAC SOLARHOOKS is a complete line of versatile attachment solutions for tile roofs. Simple to install and designed for maximum convenience, SOLARHOOKS includes an assortment of tile hooks to solve any challenge, from universal hooks to specific shapes for flat and Spanish tiles. SOLARHOOKS are kilted with lag bolts for maximum convenience and have a bead blasted stainless steel finish. With SOLARHOOKS, you have everything you need for a quick, professional tile installation. SIMPLE INSTALLATION VERSATILITY ASSORTMENT Lag bolts & EPDM washers included Available with multiple hole pattens and slotted Designs for Universal, Flat & Spanish tile connections for adjustability SOLARHOOKS APPLICATION GUIDE 0 0 MODEL PART NUMBER SOLARHOO 00 4 GT5S OLARHOOKII 001.aTtt m mi cil n jgrTlS SOLARHOOK FLAT SIDE OCAST1S MATERIAL Bead i?Iaslo: 30 S1a niossS,e;;l Hcad Biasled 304 Sla.idriss SIL rl Br"S( Biaslcd S01 SL;InIcsS Slcel Bead Blaslcd 304 Si"unlcssS Tl APPLICATION 9es!whvr;;ind s�iav legions Iksluklu% and um�':+uFJno�t DWInla., s�.Indt snoV; Bt lIll IIIvamdl ""Nis USES EXISTING TILES Ora Yn "ps CS RAIL OR RAIL -LESS Rad Fail Rail Haul MOUNTING METHOD Sido Mounl Side l' ouni Sion "h of Sido Muunl DIRECT MOUNT, NO L-FOOT REQUIRED ADJUSTABLE FLAT TILE S TILE d W TILE UNIVERSALTILE vo SIMPLE INSTALLATION NO TILE MOD. REQUIRED WARRANTY 25 2 -`lea! 25-Veto c m s m a r C) 0 TI v UD CD O C D C 3 D 0 0 m 0, OD C m A O 91 J O T 61 X J J W A A 00 00 -4 C= d< 1> pC 7� a ,95 (D a x n 0 rt FJ- G tD a HN (D rt mn NW H W � � (D 0 F'i N• H CGA rt w 0 Y F✓ �m C) q. 1"h m � n a rt a 0 G W . NWT 9C 0a CD > . IC �f VO (D N N G 0 GG(Drd0 (A (A :3 C F--' �• �• `t z rt a wtonam rt rt 0 G :j'rtNO m (D (D (D rh .. M4 rt ro 0 G H. to "0¢f00 �V F--� G - � Ft �a (D N-W W (D rt 4 l - a G• (D 0rt 000 0 G"(A0 P. �:s G 0 aron (D 0 �a v ti rt`(� 0 (DD n FiQGH (A (D (D n O rn Fl. �4 a rt P. °a J Cr H- ` CD was Q o H C ,H (D s�# w N N F-' O `A J (D W 0 0 PT, Y 0 Lrl 0 rt N- rt r- l cl cn to F- H F(� rlton R `F-C.0. .. (D - H g 0 �'•C rt 0 G 0� v 0 N cn N O O O n cD P7 structural ENGINEERS June 11, 2019 UniRac 1411 Broadway Boulevard NE Albuquerque, New Mexico 87102-1545 TEL: (505) 242-6411 FAX: (505) 242-6412 Attn.: Engineering Department, Re: Engineering Certification for UniRac's PUB 16JAN05 edition of the "SolarMount Design & Engineering Guide" PZSE, Inc. -Structural Engineers has reviewed UniRac's "SolarMount Design & Engineering Guide" published January 05, 2016 and specifically the enhancements of the SolarMount Flush -to -Roof System, Pressure Lookup Tables, and Downward & Upward Span Length Tables. This certification excludes connections to building structures and the effects on building structure components. All information, data and analysis contained within the Design & Engineering Guide are based on, and comply with the following: 1. 2015 International Building Code, by International Code Council, Inc., 2015 2. 2016 California Building Code, by California Building Standards Commission, 2016 3. ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, by ASCE, 4. 2015 Aluminum Design Manual, by The Aluminum Association, 2015 This letter certifies that the structural calculations contained within UniRac's "SolarMount Design & Engineering Guide" are in compliance with the above Codes. If you have any questions on the above, do not hesitate to call. Prepared By: PZSE, Inc. - Structural Engineers Roseville, CA 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916.961,3960 F 916.961.3965 w www.pzse.com Experience I Iniecgriiy I Empowermeni ownSM SOLAR SPAN TABLE; ■■ : MOUNT S0 LARM0� ')N i ; F.LUl)I'l- ►"')-K�() )F: EMMM 110 SMLT SMLT SM LT SMLT SM SM SM SMHD SMHD X 115 SMLT SMLT SM LT SMLT SM SM SM SMHD SMHD X 120 SMLT SMLT SM LT SMLT SM SM SM SMHD SMHD X 0 130 SMLT SMLT SM LT SM SM SM SMHD SMHD SMHD X 140 SMLT SMLT SMLT SM SM SM SMHD SMHD SMHD X 170 SMLT SMLT SM SM SMHD SMHD X X X X 110 SMLT SMLT SMLT SMLT sM SM SM SMHD X X 115 SMLT SMLT SMLT SMLT SM SM SM SMHD X X 120 SMLT SMLT SMLT SMLT SM SM SMHD SMHD X X 5 130 SMLT SMLT SMLT SM SM SM SMHD SMHD X X 140 SMLT SMLT SMLT SM SM SM SMHD SMHD X X 170 SMLT SMLT SM SM SMHD SMHD X X X X 110 SMLT SMLT SMLT SMLT SM SM SM X X X 115 SMLT SMLT SMLT SMLT SM SM X X X X' 120 SMLT SMLT SMLT SM SM SM X X X X 10 130 SMLT SMLT SMLT SM SM SM X X X X 140 SMLT SMLT SM SM SM SMHD X X X X 170 SMLT SMLT SM SM SMHD SMHD X X X X 110 SMLT SMLT SMLT SM SM SM X X X X. 115 SMLT SMLT SMLT SM SM SM X X X X 120 SMLT SMLT SM LT SM SM SM X X X X. 20 130 SMLT SMLT SM LT SM SM X X X X X 140 SMLT SMLT SM SM SM X X X X X 170 SMLT SMLT SM SM X X X X X X 110 SMLT SMLT SM SM SM X X X X X. 115 SMLT SMLT SM SM SM X X X X X 120 SMLT SMLT SM SM SM X X X X X 30 130 SMLT SMLT SM SM SM X X X X X 140 SMLT SMLT SM SM SM X X X X X 170 SMLT SMLT SM SM X X X X X X 110 SMLT SMLT SM X X X X X X X 115 SMLT SMLT SM X X X X X X X 120 SMLT SMLT SM X X X X X X X 40 130 SMLT SMLT SM X X X X X X X 140 SMLT SMLT SM X X X X X X X 170 SMLT SMLT SM X X X X X X X. 110 SMLT SMLT X X X X X X X X 115 SMLT SMLT X X X X X X X X 120 SMLT SMLT X X X X X X X X 50 130 SMLT SMLT X X X X X X X X 140 SMLT SMLT X X X X X X X X 170 SMLT SM X X X X X X X X 110 SMLT SM X X X X X X X X 115 SMLT SM X X X X X X X X 120 SMLT SM X X X X X X X X 60 130 SMLT SM X X X X X X X X 140 SMLT SM X X X X X X X X 170 SMLT SM X X X X X X X X •Rail spans are based on ASCE 7-10, Roof Zone 1, Wind Exposure C, Roof Slope of 9.46' to 26.57% Mean Roof Height of 30 ft, Seismic Coefficient Ss = 1.25, modules mounted parallel to roof surface with up -slope dimension of 67 in, and 2 rails per row of modules running perpendicular to the roof slope attached to L-feet in the down -slope orientation. The installation of SolarMount products is subject to the requirements in the SolarMount Installation Guide.