Loading...
BWFE2020-003978-495 CALLE TAMPICO D ^"t�iiGCtl LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: WALL/FENCE/CITY STANDARD/PRE-APPROVED Application Number: BWFE2020-0039 Property Address: 53005 HUMBOLDT APN: 767700005 Application Description: ROTNER / 245LF OF RETAINING WALL AT PROPERTY LINE Property Zoning: Application Valuation: $30,000.00 Applicant: n U BRADSHAW CONSTRUCTION INC L _l 81335 THUNDER GULCH WAY FEB 0 Z020 LA QUINTA, CA 92253 Cliff' 0, ! A. QUINTA DESIGN & DEVELC PmENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect License Class: B License No.: 848057 J Date: �' Contractor: ,&,), 6"J s , OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale, If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale_). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec, , B.&RC, for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec..3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/9/2020 Owner: ROTNER GLENN / ANN WALKER TRUST Contractor: BRADSHAW CONSTRUCTION INC 81335 THUNDER GULCH WAY LA QUINTA, CA 92253 (760)347-4246 Llc. No.: 848057 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of th for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Sect 3700 of the Labor Code, for the performance of the work For which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: SWE COMPENSATION INSURANCE FUND Policy Number: 9245081 I certify that in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: 20 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UPTO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES, APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter uppr the above - mentioned property for inspection purposes. Date: Signature (Applicant or Agent): �yL Date: 2/5/2020 Application Number: BWFE2020-0039 Property Address: 53005 HUMBOLDT APN: 767700005 Application Description: ROTNER / 245LF OF RETAINING WALL AT PROPERTY -LINE Property Zoning: Application Valuation: $30,000.00 Applicant: BRADSHAW CONSTRUCTION INC 81335 THUNDER GULCH WAY LA QUINTA, CA 92253 Owner: ROTNER GLENN / ANN WALKER TRUST 53005 HUMBOLDT BLVD LA QUINTA, CA 92253 Contractor: BRADSHAW CONSTRUCTION INC 81335 THUNDER GULCH WAY LA QUINTA, CA 92253 (760)347-4246 LIc. No.: 848057 Detail: 245LF TOTAL OF RETAINING WALLS AND (1) PILASTER AT AND WITHIN PROPERTY LINES. [CITY STANDARD PILASTER / ANGELUS S-1.6 AND S-1.7LQ SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. PER 2019 CALIFORNIA BUILDING CODES. Project Address- % 53`-'t.. /,/(&/K APN #: Applicant Name: Address: 4f.,4 h A► City, ST, Zip: Telephone: Email: Contractor Name: Address: _ U /� �� ■ Yl I� 1! �y � City,St, Zip Telephone: Email: State Lic: P(90 5 7 City Bus Lie: Arch/Eng Name: Address: City, St, Zip Telephone: Email: State Lic: City Bus Lic: Property Owner's Name: Address: City, ST, Zip LF Telephone: Email: PERMIT # �VJ FE2-p --+ PLAN LOCATION: Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech A . n / A . I , d, >> C k-AVtCIQ Valuation of Project $`� �� r New SFD Construction: ' Conditioned Space Garage ' Patio/Porch _ Fire Sprinklers Construction Type: Grading: Bedrooms: f Stories: SF SF SF SF Occupancy: ' # Units: New Commercial / Tenant Improvements: Total Building SF Construction Type: Occupancy: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 LOT 52 VACANT STE-DESIGM CD LOT N \ LANDSCAPE - - - -- � - wan. \" Dnf GUEST PARKING ENTRYGATE � - N m. i'PLYNTH - •. _. .. 'L46 fOURI 1R F . V C �,.c..s' ,ti'• 0 1 _ 11- : ;. ,Bao 7(7 �]'Wlr..q - ,~,.•- --�j• � GARAGE W U 4 € DRNECOURT \� KITCHEN MEDIA GARAGE fa _— O NEW i 4y ab T�t� OUTDOOR ENTRYGATE J t �'� rM ` STING ..SPA POOL UN05.p MPERA W PMW " GREATROOM 10 T 53-- 1 986.00 FF PALM COURT 985.5 PAD /' , a j 4C/• -----s �. tom, "`���; :• .. �_ o 49 t ' J HALLWAY ... i 1 MSTRBED I1 1 GUESTSED.p2 6')EVIvon GUESTEED.94 y, Nonce or Copyright 1 •+.v i a4r --� jjl °4} -- '' r�.xrur..�«tr`w vwr•r4• 1 � •N.rW.+M4n •Nx i 1 , 'm'1rw�m w��aFY-y 'Y 't . x a,w44 ' ••'•• n^ 'I - �i1GmOtq K,+4^+I� WSwr II a. ! .__—.`"_ - __ -_ - :'_:.::_r:: .:��lC-=-.:-t_._•-__:.:.-_. � N.WI�r�rrr.. r�.,w�rm �h. ' 24" RAISED PLANTER 14" RAISED PLANTER I O ! `r' /� .--. E70.4TNG i'YIALL — - _ ar +v'. /r" 0 I SITE ��{Y� LOT 54 EXISTING BUILDING " ' q° n~ Apo ��y (986 0 APPROVED PAD) OTY OF LA QUorr� B�.iILDINQ & SAY ,CHITE TURAL SITE PLAN �.O9 ' ONST[luCT10 s,-J�2.020 CCrry LOT 52 VACANT CITY OF L4 QUINTA LOT NBUILDING QM !ON LANDSCAPE MEP PLAN81DETAI.S REV MEWED FOR CO E QMPLl co CE Lo 12, 7r . tti 'LOT 53" 0 %6.00 FF M5 PAO cl) ■ Zr 7,77 T - r-1 F-7 El -Z r SITE PLAN LOT 54 —017 EXISTING BUILDING (986 0 APPROVED PAD) WAZ/ ARCHITECTURAL SITE PLAN A1.10 ......................................... F/ 73S 0E Jb 74 A (E d§ry8L0 ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pef 4. COEFFICIENT OF FRICTION = 0.25, COHESION — Opsf 5. CANTILEVER ACTIVE — 30pcf 6. MASONRY COMPRESSIVE STRENGTH, f m = 1500psi. SPECIAL INSPEC11ON NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES: 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD —DRAWN STEEL WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi ® 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE —AND —GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270, 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000pa1. 7. FIRST COURSE MAY BE WET —SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. 8. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'—D'o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED 0. GROUT ALL CELLS WITH REINFORCEMENT. 1. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 2. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK —OUT DETAILS SEE DETAIL SHEET S-5.1. MASONRY FENCE RETAINING WALL SCHEDULE ,Hr DESIGN WINDI EXP mph 'X' BARS 16" LONG CMU 'Y' BARS 16" LONG CMU]B' MIN. 'C' MI . C ® 100 4032"o.c. 4048"o.c. 2 —9" N A 2'-0" C ® 110 #4032"o.c. 4®48"o.c. 2'-9" N A C ® 120 4032"o.c. 4048"o.c. 2'-11" N A C ® 130 4032"o.c. 4®40"o.c. 3'-1. NIA C ® 100 #4®32"o.c. 4®48"o.c. 3'-0" N A 2, 8" C ® 110 4®32"o.c. 4®48"o.c. 3�—D" N A C ® 120 4032"o.c. 4@48"o.c. 3'-2" N A 2"o.c. 4040"o.c. 3'-4" NIA 2"o.c. ®48"o.c. 3'-5" N A 2"o.c. 4®48"o.c. 3'-5" N A 43'-4" 2"o.c. ti4 4®48"Sox N A4"o.C. 4®40" N A2"o.c. 4®48" 0'-2"4-0 2"o.c. 4®48" 0'-2"C ® 120 4®24"o.c. 4@48" 0'-2"C ® 130 4®24"o.c. 4®40" 0'-2" GHL INC. ARCHITECTURE < ENGINEERING 228 East Badillo Street Covina, CA 91723 T: 626.938.1595 F: 626-938-0485 _ www ghl-ae com 6' High Wall 2' to 4' Retaining Heel -in Footing C ® 100/110/120/130mph (ult.) Risk Category I 678w Wide CMU OPTIONAL WALL CAP � STD. LADDER TYPE #5 STD FOR SLUMPSTONE) JOINT REINF. AT TOP COURSE, — AT FIRST COURSE, AND 24"o.c. AT FENCE 6" OR 8" WIDE (NOM.) CMU w/ 'Y' BARS PER SCHEDULE ® CTR. OF WALL. GROUT CELLS w/ REINF. #4 HORIZ. @24" ® RETAINING 4"0 SDR 35 PERF. PIPE w/ 1c.f. 3/4" GRAVEL WRAPPED IN MIRAFI 140N FILTER FABRIC— - SLOPE TO DRAIN. WATERPROOF BACKSIDE OF RETAINING WALL 8" WIDE (NOM.) CMU_ FULLY GROUTED 'X' BARS PER SCHEDULE, LAP — 24" MIN. F.G. WET —SET FIRST ? COURSE #4 CONT. #4 CONT. ® 12"o.c.— i7 CONT. CONC. FTG. �WFeZO2.0 pD VIN tXQUIN" BUILDING DIVISION REVIEWED E0F3 CODE 0.TE? LOADING — C STY 1. SEISMIC, 5% DAMPING ® 1 SECOND ACCELERATION Cs=0.33Wt. 2. FOUNDATION SIZES BASED ON MAXIMUM WIND OR SEISMIC LOADING. H' + 12" DISTANCE TO EDGE OF NEAREST ADJACENT FOUNDATION � X I OPTIONAL CHAMFER j BACKFILL— WELL GRADED, CLEAN jr SANDS OR GRAVEL OR COMBINATION USC= GW,GP OR SW,SP 2j" OUTSIDE FACE J OF BLOCK TO OF VERT w U to ... w 9 0I I3" C R. U 2" 12�1u2" J 'B' MIN. PER SCHEDULE 9 OFESS/04^ G .� a 7 NO. 85 81 �c EXP. 9-30-20 �9r C E OF C P, DATE SIGNED 6-20-19 S-1.6 #16-077.22 R 4 BLOCK CO.. INC. Since 1946 ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4. COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf 5. CANTILEVER ACTIVE = 30pcf 6. MASONRY COMPRESSIVE STRENGTH, f'm = 1500psi. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES: 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 2. NOT USED 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi ® 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE —AND —GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000psi. 7. FIRST COURSE MAY BE WET —SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. 8. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-0"o.c. OR 20'—O"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED 10. NOT USED 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK —OUT DETAILS SEE DETAIL SHEET S-5.1. 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE H LONG CMU Y' BARS I B' MIN. I MIN. 16;D' I 0'- L 3"-4" 1 #4032"o.c. I N/A I 1'-11" 1 0'-6" 1 0'--9" 1 4--0- .1_#4032"o.c• j N/A 1 2'-5" 1 0'-8" 1 O'—Vr 2' to 6' High Retaining Wall Level Backfill 8" Wide CMU r OPTIONAL WALL CAP 26 #4 HORIZ. ®24"o.c. 8" WIDE (NOM.) CMU FULLY GROUTED 'X' BARS PER SCHEDULE — 'X' BARS PER SCHEDULE — LAP 24" MIN. 'H' + 12" DISTANCE TO EDGE OF NEAREST ADJACENT FOUNDATION BACKFILL— WELL GRADED, CLEAN SANDS OR GRAVEL OR COMBINATION USC= GW,GP OR SW,SP 4"0 SDR 35 PERF. PIPE w/ 1C.f. 3/4" GRAVEL WRAPPED IN 2j"OUTSIDE FACE MIRAFI 140N FILTER FABRIC— — OF BLOCK TO SLOPE TO DRAIN. WATERPROOF G.OF VERT, TYP. BACKSIDE OF RETAINING WALL F. G. w WET —SET FIRST COURSE #4 CONT. @12"o.c. 2—#4 CONT. CONT. CONC. FTG. „ 'Y' BARS PER 3 3" CLR. SCHEDULE �°• TYP CONC. KEY ALIGN WITH FACE OF WALL LOADING 0,_9„ 0.-9�. 1. SEISMIC, 5% DAMPING ® 1 SECOND —3" 1'-1" 1'-0" ACCELERATION Cs=0.33Wt. Yu- 4 CITY OF LA QUINTA BUILDING DIVISION 4*L228 INC. APPROVED ITECTURE - ENGINEERING 8.1Bad5oStreet Covina,CA91723FOR CONSTRUCTION 3&159538,0485 -ghkue•cvm BY: A a-li_ _DATE: 09/21/2018 pRaFES$IO �-'NC' 85581 x kEXP. 9-30-209T C / v ` \_ ('Oti OF C AGfF DATE SIGNED 9-10-18 S-1.7LQ #16-077 i 0 0 x U to w a N )L,13 1 2 7" v Iv J 27" �l TOP VIEW FOOTING BLOCK GROUT STEELREeAR REBAR PLAGEME I LLUSTRA'T N VIEW — BLOCK ?" X 1 2" OR 1 6' X 1 6") SOLID GROUT (4) - # 4 REBAR (ONE Al EACH CORNER) ALL FOOI',NGS ADJACENT TO SLOPES TO BE AT LEAST 5' TO DAYLIGHT AS SHOWN BELOW. MIN-2 RF8A OVERL 0 �- �,., S' M I N FOOTING LIMITATIONS: CTIN'G RL-`E'AR SHALL wEn MIN.6" c-oNG 1 -PILASTER SPACING Sh1Al-.I. NOT EXCEED 20 Fr. WHEN OTHER INFR_I_ Fi'.NCING r{ool�AND Ar.rw, ;SATTACHED. C9FTF CQVFR OF 3-'. 2 ONLY OPEN TYPE FENCING (SUCH AS WROUGHT IRON) MAY BE ATT'ACHiw TO PILASTERS. SOLID TYPE FENCING MAY NOT BE ATTACHED TO Pil ASTER. 3. GATES AND DOORS ATTACHED TO PILA51-ER ARE LIMITED To 200# MAX - WEIGHT AND 4 FT. MAX. WIDTH PER PILASTER. 4.Ti,ils PILASTER DESIGN IS INTENDED TO BE. USED ONLY AS A FENCING 27„ _ FEATURE AND IS NOT INTENDED TO SUPPORT ANY OTHER LOADS. 5, FENCE HE1GH'fS ARE REGULATED — CONSULT ZONING REGULATIONS BEFORE CHECK WITH THE BUILDING DEPARTMENT BEGINNING CONST'RUC TION, TO VERIFY IF A BUILDING PERMIT IS REQUIRED. 6-INSTALLATION OF ELECTRIC CIRCUITS, CONDUITS. OR LIGHTING FIXTURES WHEN A BUILDING PERMIT IS REQUIRED, REQUIRE ELECTRICAL PERMITS AND INSPECTION. THE FOLLOWING INSPECTIONS ARE ALSO REQUIRED; 7, F OOTINGS T'O BE PLACED IN UNDISTURBED SOIL OR PROPERLY COMPA01'ED AND ENGINEERED FILL. 1) FOOTING: EXCAVATION TRENCH CLEAN WITI-I STEEL B. FOR DESIGN PARAMETERS. SEE FREESTANDING BLOCK WALL STANDARD. IN PLACE AND SUPPORTED 3" ABOVE AND AWAY FROM WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM THE SURROUNDING THE EARTH/DIRT. 2) REBAR/PRE-GROUT; VERTICAL REBAR IN PLACE - r e INSPECTION PRIOR TO PLACING GROUT. 3) FINAL; AFTER GROUT IS PLACED - PRIOR TO ANY M "� • ,�f. DECORATIVE CAP PLACEMENT. r MASONRY PILASTER DISCLAIMER: ALTERNATE DESIGNS MAY BE POSS113LE WHEN PROVIDED WITH AN ENGINEERED ANALYSIS, USE OF THIS STANDARD DESIGN IS PHONE 760 177-7125 78.495 CALLC 9'RMI'lC;i] AT' THE USER'S RISK AND GARRIES NO IMPLIED OR INFERFLED ( ) LA QUINTA, CAI.-PORNIA ()'1253 GUARANTEE AGAINST FAILURE ORDEFECTS, IVAV 17r;M 777-7(111 1 ChMMUNITY❑CVCI.OP\9L:N'fDL:F'T I PAGEI Of I Armando Magallon From: Jonathan Van Alstine <jonathan@markbradshawconstruction.com> Sent: Thursday, February 6, 2020 12:17 PM To: Armando Magallon Subject: Fwd: Signatory authorization EXTERNAL: This message originated outside of the City of La Quinta. Please use proper judgement and caution when opening attachments, clicking links or responding to requests for information. Jonathan Van Alstine Bradshaw Construction 760.766.6189 Begin forwarded message: From: Kelly Bradshaw <kelly.bradshaw@markbradshawconstruction.com> Date: February 5, 2020 at 5:04:06 PM PST To: Jonathan Van Alstine <jonathan@markbradshawconstruction.com> Cc: Mark Bradshaw <mark@ markbradshawconstruction.com>, David Miller <david @ ma rkbradshawconstruction.com> Subject: Re: Signatory authorization You are approved to sign the permit Kelly Bradshaw Bradshaw Construction On Feb 5, 2020, at 3:10 PM, Jonathan Van Alstine <jonathan@markbradshawconstruction.com> wrote: Hey Mark or Kelly whichever one of you get to it first, could you email me back with approval to sign for permits. Thanks Jonathan Van Alstine Bradshaw Construction 760.766.6189