Loading...
Griffin Ranch - Belmont Collection TR 32879 14-0494 (SFD) (Series I; Plans 1-4) 2013 Code Update - Title 24..... ...... ...... ...... 7544 SADDLEHILL TRAIL, ORANGE, CA 92869 - (714) 771-1507 ® FAX (714) 771-2939 - T-24@socal.rr.com December 4, 2013 Revised: 01/10/14 (Project Name & Miscel. Glass) ,Iwner-. Lennar Homes/Corona 980 Montecito Drive, Suite #302 Corona, CA 92879 esigner: The McKinley Associates, Inc. 1818 First Avenue San Diego, CA 92101 RECEIVED Project: "Belmont Collection" (Series 1) Plans 1, 1-w/Casita, 2, 3 & 4 MAY 2 2 2014 La Quinta, California CITY OF LA I QUINTA Job No. 12-13 t)p WUUNITY DEVELOPMENT 2,015 C006"' U04W VENTILATION FOR INDOOR AIR QUALITY The following calculations are in compliance with section 150(o) of the 2008 Building Energy Efficiency Standards for low-rise residential buildings. The ventilation fan selection has a certified airflow rating that meets or exceeds the required minimum airflow when measured @ .25" w.c. for continuous operation. The minimum duct size specified must meet the requirements of Table 4-9 in the Residential Energy Manual. In addition, other mandatory requirements for indoor air quality are listed on the following pages. Prepared By: B 1W7,C neq r rR!C,,7 Maurer California Association of Buildihq E: j Consultants.. '�S erQUINTA Energy'Plansl� arAinA Rick Maurer Certificate No. R06464"661II(kPd f4kOff-W-35013T. California State Li(P,I1b50229 O �LQROB-90-243&ROB-90-527 A-4��JEJ FOR CONSTEUCTION DATE 11 BY . . .. ... ......... ............. Plan #1 2967 -, 100 + 7.5 (3 + 1) = 29.67 + 30,0 = 59.67 in. CFM 2TAIRMT 04 M01 Broan #SSQTXE1 10 (or Equal) (One Required) 90 CFM @.25" W.G. .7 Sones Ventilation Exhaust Duct Size: 6"0 Flexible Metal Duct (or alternate per Table 4-9 CEC Residential Manual) 125' Max. Length Less 15' for each elbow Plan #1 w/Casita House 2967 100 + 7.5 (3 + 1) = 29.67 + 30.0 = 59.67 Min. CFW Fan Selection: Broan #SSQTXE1 10 (or Equal) (One Required) 90 CFM @.25" W.G. .7 Sones Ventilation Exhaust Duct Size: 6"0 Flexible Metal Duct (or alternate per Table 4-9 CEC Residential Manual) 125' Max. Length Less 15' for each elbow Casita 304 - 100 + 7.5 (1 + 1) = 3.04 + 15.0 = 18.04 in. CFM Fan Selection: Broan #SSQTXE080 (or Equal) (One Required) 55 CFM @..25" W.G. 3 Sones Ventilation Exhaust Duct Size: 6"0 Flexible Metal Duct (or alternate per Table 4-9 CEC Residential Manual) No Limit on Duct Length Plan #2 3153 - 100 + 7.5 (3 + 1) = 31.53 + 30.0 = 61.53 Min. CFM Fan Selection: Broan #SSQTXE1 10 (or Equal) (One Required) 90 CFM @.25" W.G. .7 Sones Ventilation Exhaust Duct Size: 6"0 Flexible Metal Duct (or alternate per Table 4-9 CEC Residential Manual) 125' Max. Length Less 15' for each elbow Plan #3 3771 100 + 7.5 (4 Fan Selection: Broan #SSQTXE1 10 (or Equal) (One Required) .7 Sones Ventilation Exhaust Duct Size: 6"0 Flexible Metal Duct (or alternate 125' Max. Length Less 15' for each CITY OF LA QUINTA BUILDING & SAFETY DEPT. per Tabl'e.4*---"9'fc7E,7cli�,-�e;dent as Manua elbow CONSTRUCTION DATE - BY 11�11111'11 INIIIIIIIIII !Iimvijii��Ij jj� 11 1 III !I11111111111IF I I 0 mmmmj Plan #4 3745, 100 + 7.5 (4 + 1) = 37.45 + 37.5 = 74.95 Min. CFM Fan Selection: Brun #SSQTXE 110 (or Equal) (One Required) 90 CFM @.25" W.G. .7 Sones Ventilation Exhaust Duct Size: 6"0 Flexible Metal Duct (or alternate per Table 4-9 CEC Residential Manual) 125"Max. Length Less 15'for each elbow CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE 13Y-----� • .. ..... . . .• .......... All low-rise residential buildings are required to have a whole -building ventilation system and satisfy other requirements to achieve acceptable indoor air quality (IAQ). The Energy Commission adopted the requirements of ASHRAE Standard 62.2-2007, except that opening and closing windows (although permitted by ASHRAE) is not an acceptable option for providing whole -building ventilation in California. The mechanical ventilation and indoor air quality requirements are mandatory measures. The applicable sections are §1 50(o) for new construction and §1 52(a) for additions. The following bullet points summarize the key requirements for most residences. • A whole -building mechanical ventilation system shall be provided. • Kitchens and bathrooms shall have local exhaust systems vented to the outdoors. • Clothes dryers shall be vented to the outdoors. • Ventilation air shall come from the outdoors and shall not be transferred from adjacent dwelling units, garages or crawlspaces. • Ventilation system controls shall be labeled and the home owner shall be provided with instructions on how to operate the system. • Combustion appliances shall be properly vented and air systems shall be designed to prevent back drafting. • The wall and openings between the house and the garage shall be sealed. • Habitable rooms shall have windows with a ventilation area of at least 4% of the floor area. • Mechanical systems including heating and air conditioning systems that supply air to habitable spaces shall have MERV 6 filters or better. Air inlets (not exhaust) shall be located away from known contaminants. • Air moving equipment used to meet either the whole -building ventilation, requirement or the local ventilation exhaust requirement shall be rated in terms of airflow and sound. a. All continuously operating fans shall be rated at a maximum of 1.0 sone. b. Intermittently operated whole -building ventilation fans shall be rated at a maximum of 1.0 sone. c. Intermittently operated local exhaust fans shall be rated at a maximum of 3.0 sone. I _ , -, 1 4% rNI 11%rrA I d. Remotely located air -moving eqL spaces) need not meet sound re, ductwork between the fan and th • A minimum intermittent ventilation airflow range hood and a minimum intermittent v the bath fan. A lie of intak,eWrilPROVEU 100 OM Wd&JAPDRA� kite en ilation airflow of 50 CFM is required for DATE _ BY_� } Page 4 74 Bulldina HVAC Requirements — Indoor Air Quality and Mechanical Ventilation Page 4-75 Airflow Rating -------------- ... From ASHRAE 62.2-2007 Section 7.3 Airflow Rating The airflows requited by this standard refer to the delivered airflow of the system as installed and tested using a flow hood, flow grid, or other airflow measuring device. Alternatively, the airflow rating at a pressure of 0.25 in. w.c. may be used, provided the duct sizing meets the prescriptive requirements of Table 7.1 or manufacturers' design Compliance with the ventilation airflow requirements for a ventilation system can be demonstrated in one of two ways: f. The ventRation system can be tested using an airflow measuring device after completion of the installation to confirm that the delivered ventilation airflow meets the requirement. The builderrnstaller must also list the result of the airflow measurement(s) for the ventilation fan(s) on the Installation Certificate (CF-§R-MECH-05) for the building. The ventilation airflow must be measured and reported for any/all ventilation system types installed in the building, except for those described in item 2 below. 2. Simple exhaust systems can comply by performing and documenting an inspection of the installation to verify conformance to a prescriptive requirement that the fan has a certified airflow rating that meets or exceeds the required ventilation airflow, and the ducts for the ventilation system meet either the fan manufacturers published duct design specifications, or the prescriptive duct design requirements given in Table 4-9 below (Table 7.1 of ASHRAE 622). The builder(tnstaller must also list the description of the installed fan equipment and duct design criteria for the ventilation fan(s) on the Installation Certificate (CF-6R-MECH-05) for the building. The fan(s certified airflow rating must be based on tested performance at the 0.25 inch w.c. operating point. The certified airflow rating of a ventilation device is generally available from the manufacturer, and is also available for hundreds of products in the Home Ventilating Institute (HVI) Certified Products Directory at the HVI website (vntibv-hvi.orr,). Manufacturers can choose whether to provide the certified data for posting at the HVI website, but all of them should have available the rated data at 0.25 inches of water column static pressure. If the manufacturer's duct system design specifications are utilized for compliance, the enforcement agency may require that the manufacturer's published system design documentation be provided for use in inspection of the installation(s). The prescriptive duct design criteria given in Table 4-9 provide maximum duct based on various dud diameters and duct type. As can be seen, the higher the flow, the larger in diameter or shorter in length the duct has to be- Also note that smooth duct can be used to manage longer dud runs. interpolation and extrapolation of table 4-9 (Table 7.1 of ASHRAE 62.2) is not allowed. For airflow values not listed, use the next higher value. The table is not applicable for systems with airflow greater than 125 chn at 0-25 inches of water column static pressure. Table 4-9 — Prescriptive Duct S&Wg for Single Fan Exhaust Systems (from 62.2, Table 7.1) Duct Tye FkX Duct Qu�e�---1 Fan Ra, (dm@ 025 in. w.c.) C;I�(F 50 tie .. 1®f�1215 I tI. ... 1lL IN Sa &o�A„ Et � [� �Pt�S .... Diameter kWh .:: Ma L g�PROVED e u+ 3 x X x x }-Rff — J'\ Ti-T X 4 70 3 x x 105 3b 5 X 5 NL 35 20 .-,......_..-- GNL M Y II5 ... `— 6 _. NL t� 12S 95 NL _ _ N .. � ,,.... 5 7 and above NL Nt-' NL NL NL NL NL NL This table assumes no elbows. Deduct 15 feet of allowable duct length for each elbow. NL = no limit on duct length of this size. x = not allowed, any length of duct of this size with assumed turns and fitting will exceed the rated pressure drop. Whole House or Continuous refers to providing a consistent level of ventilation throughout the day in order to remove indoor air pollutants of all types. The maximum sound level is 1.0 Sones. To determine the cfm requirements for whole house or continuous ventilation, ASH RAE provides a simplified* table (A) based on size of the home and number of bedrooms. The cfm levels in the chart can be met by testing the installed ventilation devices for actual airflow or simply using the certified ratings of a fan at 0.25" static pressure assuming a proper duct size is used. The minimum duct diameters are listed in Table B and show that 6" ducted fans are the acceptable choice for al I installations. It is only acceptable to use 4" duct for installations using a 50 cfm fan or an 80 cfm fart where duct length is 3' or less without bends. TABLE A TABLE B Bedrooms Floor Area (W) _ 0-1 2-3 4-5 6-7 >7 <1500 30 45 60 75 90 1.501-3000 .45 60 75 90 105 3001-4.500 60 75 90 105 120 4501-6000 75 90 105 120 135 6001-7500 90 105 120 135 ISO 7500 105 120 135 150 165 Requirements are mloirriurns and a%sume continuousfy rt<nning fans. -Table A is dervied from the following formula which can also be Used: CFM = (sq. ft. x .01) + 7.5 x (no. of bedrooms + 1) Mote: Larger fans with more cfrn are always better to remove steam more quickly. 'lex Duct Smooth Duct Fan Rating @ 0.25 in. w..g._ 50 80 100 50 so 100 Diameter, in. Maximum Length, ft. 3' X X X .51 X X 4P 70' 3' x 105' 35' 5' 6" oo — 125' o0 oa — Assumes no elbows. Deduct 1.5 ft of ;allowable duct length for each elbow. — = infinite or unlimited X = not allowed, any Iegth of duct of this size with assurned turns and fining will exceed the rated pressure drop. Meet Standard 62.2 Whole House Ventilation Requirements With These Fans From Broan-NuTmne Models in the chart are color -coded to correlate with Table A. Multiple fans are needed for larger homes requiring more than 90 cfm. HVI Certified. Duct HVI Certified. Energy CFM @ 0,25rt:'.Dekr€' tiort Broan Model KuTone Model Size Sones @ 0.1" Star 39 50 CFIu1 Fan QTXE050 QTXEN050 6tt <0.3 Yes 55 80 CFM.F:an. QTXE08 i .: QTXEN080 6® 0.3 Yes I 55 80 CFM SmartSenses Fist aSQTXE080.. 6' Im 0.3 Yes om- 5° 80 as?tLgtr` QTXFt BOFLT QTXEN080FLT 6° 6:3:. `its 55 80 CFM Fan QT12E080 QTREN080 4" 0.9 'Yes 55 : 80 CFM FanJFluorescent Light i T QT. ENitbOFI T A.".. des 67 80 CFM Fan Qr.11 8.6 QTRN080:. 4" 1.0 No 67 80 CFM Fan/Light 47"ROSOL; QTRN080L ": 1,0 No 82 110 CFM Heater/Fan/Light QTX110.HFL QTXN114HFL 0. 0_9, No 90 . 110 CFM HumiditySensing Fan QT1t lICtS' "QTXEhIaIOS f"' 0 3'es 110 CFM Fan .. tT3(E:17E : QTXEN110 6" 0:7 Yes 90 110 CFM Smarts6nse `Fan' SsQTXEII€i' 6' 07 'Yes .90 110 CFM Humidity Saitslnt� Tar4lFluaresrettt Llr7lit Q7XE11051 t i Qi XEN110S1 LT 68 ti 7: Yes 90 lid CFM tlttrrilditlrStn�lni� FtraLigrst QTXE110SL QTXEN110SL 6'° 09 No 90 110 Cl rvl FaaUl Euaresceti Light>, Q . IIQFLT; QTXEN1,lOFLT 6®. 0:7 'Yes Local (Intermittent) entii a ire a is Local or Intermittent Ventilation refers to usage such as to remove humidity from showers or cooking at a maximum sound level of 3.0 Sones. It requires a rating of at least 50 cfm at 0.25" of static pressure and a maximum of 3.0 Sone rating at 0.1" of static pressure. All models in the above chart (except QTXE050 and QTX EN050) meet the requirement as do the following: Broan (NuTone Fans QTXE150, QTR140,QTRE110, QTR110, QTXEN150, QTREN110, QTRN110, HD80NT, QTRE100S, QTR070, HD80, 683, 684 67-1=R,-8832=WH; 8832�1�'--1 Fart/Lights QTXE1501 LT, QTR140L, QTRE11©FLT, QT!X�EN15dFLtT�t TRENsftOF T,r,T]k l A0, lD80LNT, QTR110L, QTR070L, 744, 744FL, 683L, 757SN 744NT,744FINT, cR5 SNN , 7 8CHN'T `769 lL, 769RFT Beater/Fan/Lights 100HL, 100HFL 765HL,APPROVED FOR CONSTRUCTION BR I' NUTon www.Broan.com - www.NuTone.COM ATE BY Broan-NuTone LLC, 926 W. State Street, Hartford, WI 53027 ° 800-558-1711 In Canada call 877-896-1119 I Improve air quality throughout the horse automatically and efficiently - a smart solution to home ventilation. FEATURES • Removes pollutants such as house hold cleaners, VOC's, carbon dioxide/monoxide, and off -gassing from building materials, carpets and other furnishings • Helps remove gases and particles that are not trapped by any filtration unit • Program a single control for a ventilation rate to match the size of the home • Automatically adjusts total run-time based on square footage and number of bedrooms • Optimizes energy usage by monitoring normal fan operation and adjusting automatic ventilation time as needed • Continuously monitors and if necessary, activates other Broan SmartSense® systems located in different loca- tions within the home — day and night • No control wiring required — controls communicate over existing home power wires • Uses less than 40 watts during ventilation cycles — in most installations • Cost effective and energy efficient ventilation strategy • Broan Ultra SilentTM fans operate at a barely audible 0.3 (80 CFM fans) or 0.7 Sones (110 CFM fans) • Easy installation of fans in the ceiling, vented to the exterior using 6-inch duct • Up to 10 systems can be combined into an air quality network • Meets ASHRAE 62 — related ventilation requirements Broan SmartSense® uses INSTEON'", a powerful, wireless home control technology It4STEUN E N A 6 E. E D Broan-NuTone LLC 80 CFM FAN (Model QTXE080) 110 CFM FAN (Model QTXE110) (see fan spec sheet,) SSQTXE080 Contains: 1 - 80 CFM Fan (Model QTXE080) 1 - SmartSenseO Control a 1� ONTROL PHASE .ecommend COUPLER inglee--gang (Recommend deep :ctrical box) single -gang electrical box) SSQTXE110 Contains: 1 -110 CFM Fan (Model QTXE 110) 1 - SmartSenseO Control SMSCPLR Phase Coupler Required for multiple systems on opposite electrical power phases CONTROL. SPECIFICATIONS Paddle Type: Rocker action Color: White Paddle & Trim Frame Almond Paddle & Trim Frame included Conditions: Indoor, 400 to 104" F, up to 85% relative humidity Supply Voltage: 120 VAC +/- 10%. 60 Hz, single phase Max. Load: 480 Watts incandescent, 13A resistive Certification: Safety tested for use in USA and Canada (ETL#3017581) Hartford, Wisconsin www.broan.com 800-558-1711 REMARK Pro1jr UI I i � —L_c tion II`�..1`%V BUILCJ4�V NE i . �?, ete�gct_ �PF�`a� FOR C n, �, Contractor y Su tted b Date .. 99044388A MODEL STATIC MOE ORURIE 6 DETAILS PRESSURE" CFM" SONES WATTS OR,' QTX110,SL 110 0.9 33.5 @ 0.25 SP 90 33.0 QTXE050 60 <0.3 19.7 @ 0,25 SP 39 19.2 QTXE080 80 0.3 23.3 @ 0.25 SP 55 23.2 QTXE080FLT 80 0.3 23.3 @ 0.25 SP 55 23.2 QTXE110 110 0.7 33.5 @ 0.25 SP 90 33.0 QTXE110FLT 110 0.7 33.5 @ 0.25 SP 90 33,0 QTXE110S 110 07 33.5 @ 0.25 SP 90 33.0 QTXEI 10SFLT 110 0.7 33.5 @ 0.25 SP 90 33.0 QTXE150 150 1.4 51.3 @ 0,25 SP 118 50.1 QTXE150FLT 150 1.4 51.3 @ 0.25 SP 1185 01 80 @ 0.25 SP 55 0.3 23 23.2 SSQTXE110 @ 0.25 SP 110 90 0.7 33.5 33,0 Downdraft Kitchen Exhausters 273003 500 273603 500 RNIDD3004 500 RMDD3604 600 RMDD4804 500 Infine Fans (all models) MP109 @ 0 20- SP 110 @ 0.40'SP 98 MP140 @ 0.20- SP 150 @ 0.40' SP 141 MP200 @ 0.20' SP 210 @ 0A0- SP 200 MP280 @ 0.20- SP 290 @ 0.40- SP 265 HLB3 Ver. HS+ @ 0.20- SP 260 Hor. HS+ @ 0.20- SP 280 HLB6 Ver. HS+ @ 0.20- SP 600 Hoc HS+ @ 0.20- SP 600 HLB9 Ver. HS+ @ 0.20- SP 700 Hor. HS+ @ 0.20' SP 800 Rev. 08/0112010 %N PRODUCTS Section 1 -11 EL STATIC ' CRIES DETAILS PRESSURE" CFM" SONES WATTS, HLJB1 I Ver, HS+ @ 0.20- SP 1000 Hor. HS+ @ 0.20' SP 1100 SP100 @ 0.20' SP 110 @ 0.40- SP 97 SP140 @ 0.20- SP 150 @ 0.40- SP 133 SP200 @ 0.20- SP 210 @ 0.40' SP 195 Kitchen - Exhaust Fans 12C 370 8.0 502 270 8.0 503 160 5.0 504 350 6.5 505 180 6.5 506 470 8.0 507 250 7.0 508 270 6.0 509 180 6.5 509S 180 6.5 509SMX 180 6.5 L509SM 180 6.5 Kitchen Range Hoods - Ducted & Convertible 103023 Ver. HS+ 360 5.0 Hor, HS+ 360 4.5 113023 Ver. HS+ 360 4.5 Hor. HS+ 360 4.5 113042 Ver. HS+ 190 8.5 Hor. HS+ 200 8.5 153001 Ver. HS+ 300 4.5 15M02 Ver. HS+ 300 4.5 153004 Ver. HS+ 300 4.5 153023 Ver, HS+ 300 4.5 153601 Ver. HS+ 300 4.5 153602 Ver. HS+ 300 4.6 153604 Ver. HS+ 300 4.5 153623 Ver. HS+ 300 4.5 402101 Ver. HS+ 160 6.5 Hor. HS+ 160 6.5 402102 Ver. HS+ 160 6.5 Hor, HS+ 160 6.5 402108 Ver. HS+ 160 6.5 Hor. HS+ 160 6.5 402401 V BS+ .,4W OF LAQUIN.PFA" 160, .5 402402 Q.1j�-.S+Ql1NG & SAFETY DEPT. 160 .5 Hor. HS4, PROV 60 402404 CONSTRU 2; 1 � QTA V 0- -y LPT. 402408 FA W7 B f - . n FC)i STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)): Direct Discharge Fans (Non -Ducted) @ 0.03 in. I Ducted Fans @ 0.10 in. wg; 0.25 In, wg (optional) Infine Fans @ 020 In. wg; two additional (option Qbk"c Pressure wiY CONVERSIONS: Pascals (Pa) = in. wg x 250 Litres per Second (LJs) = clanx 0.47 ------------ NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY, LACE AAUU11rTITLE 24, INC. 7544 SADDLEHILL TRAIL, ORANGE, CA 92869 - (714) 771-1507 - FAX (714) 771-2939 - T-24@socal.rr.com December 4, 2013 Revised: 01/10/14 (Project Name & Miscel. Glass) Owner: Lennar Homes/Corona 980 Montecito Drive, Suite #302 Corona, CA 92879 Designer: The McKinley Associates, Inc. 1818 First Avenue San Diego, CA 92101 Project: "Belmont Collection" (Series I) GiTY (��''�---_ Plans 1, 1-w/Casita, 2, 3 & 4 e(J1LDIt�G �'`�A Q UIIN `TA La Quinta, California APPPQEPT Job No. 12-13 FOR C nn n� (C4) UP DATrDA-FErJ l �aE�' Y This Calculation contains all the building features and performance specifications required for compliance by the California Code of Regulations Title 24, Part 1, Administrative Requirements; Part 6, Building Energy Efficiency Standards; and portions of Title 20, Appliance Efficiency Standards. When these features are incorporated into the architectural plans the design will be in compliance with the 2008 Energy Efficiency Standards as they apply in Climate Zone 15, using MICROPAS8 Version 8.1, a California Energy Commission approved computer performance method program. r✓ California Association of Buildirtq i ne*Kgy Consultants LeJaCau*A=1 lgrg grg"rilffkm Rick Maurer R08-90-243 & NR08-90-627 Prepared By: Rick Maurer Energy Plans Examiner Certificate No. R08-88-1601 and NR08-88-3583 California State License No. 502290 C20 ** SUMMARY SHEET ** ro"ect L:enar Homes - La ufnt GAran+e. "Belmont Collection" (Series 1) Plan 1 Wall Insulation: R-15 in 2x4 Exterior Walls R-21 in 2x6 Exterior Walls R-21 in Attic Knee Walls Ceiling Insulation: R-38 Radiant Foil Barrier: Required @ Roof o/Conditioned Space & Attic Gable Ends (Requires an Emittance of 0.05 or less) Raised Floor Insulation: N/A Slab Edge Insulation: None Glazing Type: All glass is DUAL PANE with High Performance Low-E Glass. (See Notes) Hard Surface Flooring: None Required Minimum Furnace AFUE: 80% AFUE Minimum Heating Capacity: 49,428 BTUH Minimum A/C SEER: 13.0 SEER/11.5 EER Rater Verged A/C Tonnage: Min.Sens.= 36,709 @ 1150 (A/C Size By Mechanical Contractor) Duct Insulation: R-6.0 For Ducts & Plenums in Unconditioned Spaces (Duct Leakage Test Required) Note(s): 1) This house will have Cool Roof rated concrete tiles with .16 minimum aged reflectance and .89 minimum emissivity. 2) All hot water lines will be insulated per Sec. 150(J) with a minimum of 1 inch insulation. This is an addition to the insulation required by the mandatory requirements. t-- 3) The water heater for this house will have a hot{ watdemand�type recirculating system with manual control. B f LA - T� r- 4) This house will have a tankless water heater withtan energyifactor,� f� 2 or greater and sized per the owner's spec cations; Co �0V�p �STI?r � 5) All windows and glass doors will have non-metal frames with�aTweighted iJq 1 average NFRC U-factor of .35 or less and a weig _ ted average SHGC of .25 or less with high performance Low-E (Max) gla s�e� / *_* SUMMARY SHEET ** Proxect. _ Lennat H04fies La Uinta C. Zone: 1!5 "Belmont.Collection" (Series 1) Plan 1 AA�ita Wall Insulation: R-15 in 2x4 Exterior Walls R-21 in 2x6 Exterior Walls R-21 in Attic Knee Walls Ceiling Insulation: R-38 Radiant Foil Barrier: Required @ Roof o/Conditioned Space & Attic Gable Ends (Requires an Emittance of 0.05 or less) Raised Floor Insulation: N/A Slab Edge Insulation: None Glazing Type: All glass is DUAL PANE with High Performance Low-E Glass. (See Notes) Hard Surface Flooring: None Required Minimum Furnace AFUE: House = 80% AFUE Casita = 7.7 HSPF Minimum Heating Capacity: House = 49,428 BTUH Casita = 8,954 BTUH Minimum A/C SEER: House = 13.0 SEER/11.5 EER Rater Verified Casita = 13.0 SEER/11.0 EER Rater Verified A/C Tonnage: House = Min. Sens. = 36,688 @ 1150 Casita = Min. Sens. = 6,049 @ 115° (A/C Size By Mechanical Contractor) Duct Insulation: R-6.0 For Ducts & Plenums in Unconditioned Spaces (Duct Leakage Test Required) Note(s): 1) This house will have Cool Roof rated concrete tiles with .16 minimum aged reflectance and .89 minimum emissivity. 2) All hot water lines will be insulated per Sec. 1'50(J)-with a minimum of 1 inch insulation. This is an addition to the insulation required:by the mandatory requirements. �OL_DING & 3) The water heaters for this house will have a hotrwater-"demand,type'recir"culatinI system with manual control. FOR CANS RU - cr1oN 4) This house will have two tankless wate � heaters with an energy factor of .82 or greater and sized per the owner's specifications-.---, sY 5) All windows and glass doors will have non-metal frames wli a weighted average NFRC U-factor of .35 or less and a weighted average SHGC of .25 or less with high performance Low-E (Max) glass. ** SUMMARY SHEET ** Proiect: _Lennar Homes. -- La Quinta., CA Zone: 16. "Belmont Collection" (Series 1) Plan 2 Wall Insulation: R-15 in 2x4 Exterior Walls R-21 in 2x6 Exterior Walls R-21 in Attic Knee Walls Ceiling Insulation: R-38 Radiant Foil Barrier: Required @ Roof o/Conditioned Space & Attic Gable Ends (Requires an Emittance of 0.05 or less) Raised Floor Insulation: N/A Slab Edge Insulation: None Glazing Type: All glass is DUAL PANE with High Performance Low-E Glass. (See Notes) Hard Surface Flooring: None Required Minimum Furnace AFUE: 80% AFUE Minimum Heating Capacity: 51,925 BTUH Minimum A/C SEER: 13.0 SEER/11.5 EER Rater Verified A/C Tonnage: Min.Sens.= 39,169 @ 1150 (A/C Size By Mechanical Contractor) Duct Insulation: R-6.0 For Ducts & Plenums in Unconditioned Spaces (Duct Leakage Test Required) Note(s): 1) This house will have Cool Roof rated concrete tiles with .16 minimum aged reflectance and .89 minimum emissivity. 2) All hot water lines will be insulated per Sec. 150(J) with a minimum of 1 inch insulation. This is an addition to the insulation required by the mandatory requirements. 3) The water heater for this house will have a hot watedemand, type recir_cul system with manual control. ��fLp�NG & AFQ01NT,q 4) This house will have a tankless water heater with a � ne gy or�°f 82X greater and sized per the owner's spec�ications. CONS'-RUC7 �qN 5) All windows and glass doors will have no -foetal frames with a weighted average NFRC U-factor of .35 or less anA�a-wei�ed-averaage SHGC of 5 or less with high performance Low-E (Max) glass. ** sumMA ty SHEET ** Project: Lennar Homes -. La Quinta CA .........Zone:. 1S. "Belmont Collection" (Series 1) Plan 3 Wall Insulation: R-15 in 2x4 Exterior Walls R-21 in 2x6 Exterior Walls R-21 in Attic Knee Walls Ceiling Insulation: R-38 Radiant Foil Barrier: Required @ Roof o/Conditioned Space & Attic Gable Ends (Requires an Emittance of 0.05 or less) Raised Floor Insulation: N/A Slab Edge Insulation: None Glazing Type: All glass is DUAL PANE with High Performance Low-E Glass. (See Notes) Hard Surface Flooring: None Required Minimum Furnace AFUE: 80% AFUE Minimum Heating Capacity: 64,597 BTUH Minimum A/C SEER: 13.0 SEER/11.5 EER Rater Verged A/C Tonnage: Min.Sens.= 47,035 @ 115* (A/C Size By Mechanical Contractor) Duct Insulation: R-6.0 For Ducts & Plenums in Unconditioned Spaces (Duct Leakage Test Required) Note(s): 1) This house will have Cool Roof rated concrete tiles with .16 minimum aged reflectance and .89 minimum emissivity. 2) All hot water lines will be insulated per Sec. 150(J) with a minimum of 1 inch insulation. This is an addition to the insulation required by the mandatory requirements. fC/ TY n r- r 3) The water heaters for this house will havea hot�water-d;m-a-pd�type=recirculating system with manual control. �.,, C &SAFE7-y CEP 4) This house will have two tankless water heaters 4h an�ene gy factor of .82 or greater and sized per the owners spyecifications. RUCTION I DA-r, 5) All windows and glass doors will have non-metal frames with a weighted average NFRC U-factor of .35 or less and a-wei to"`average SHGC of .25 or less with high performance Low-E (Max) glass. W ** SUMMARY SHEET ** Pro'ect: Lennar Homes -- La guinta, CA Zone: ____1.5 "Belmont Collection" (Series 11 Plan 4 Wall Insulation: R-15 in 2x4 Exterior Walls R-21 in 2x6 Exterior Walls R-21 in Attic Knee Walls Ceiling Insulation: R-38 Radiant Foil Barrier: Required @ Roof o/Conditioned Space & Attic Gable Ends (Requires an Emittance of 0.05 or less) Raised Floor Insulation: N/A Slab Edge Insulation: None Glazing Type: All glass is DUAL PANE with High Performance Low E Glass. (See Notes) Hard Surface Flooring: None Required Minimum Furnace AFUE: 80% AFUE Minimum Heating Capacity: 68,824 BTUH Minimum A/C SEER: 13.0 SEER/11.5 EER Rater Verified Fan Watt Draw to be Rater Verified Adequate Cooling Coil Airflow to be Rater Verged A/C Tonnage: Min.Sens.= 56,101 @ 1150 (A/C Size By Mechanical Contractor) Duct Insulation: "R-6.0 For Ducts & Plenums in Unconditioned Spaces (Duct Leakage Test Required) Note(s): 1) This house will have Cool Roof rated concrete tiles with .16 minimum aged reflectance and .89 minimum emissivity. 2) All hot water lines will be insulated per Sec. 150(J) with a minimum of 1 inch insulation. This is an addition to the insula ion required by the mandatory requirements. -•17 Y OF. 3) The water heaters for this house will have a hot wateFdemand type recircul'atin system with manual control. �p1Fop ("' `�" Y DEpT 4) This house will have two tankless water heaters with an'�energy�;factor of .82 or greater and sized per the owner's specifications. �� 5) All windows and glass doors will have nor"tal fr=am_ es with -a weighted average NFRC U-factor of .35 or less and a weighted average SHGC of .25 or less with high performance Low-E (Max) glass. Prior to final inspection, a copy of the following checked installation certificates shall be posted or made available with the building permit(s) issued for the building and shall be made available to the enforcement agency for all applicable inspections. Installation Gertificate CC-6RNY=p1-.IIVIo . >- trllatic ,:Fenestration ..:........ CF.FiR�.FNV-2(�HFRS—"E3ttt�f`�E71_�Jtt�% ,<..__ Dt d1.1 MandatO Measures Sutnma MF-1R Residential Enforcement Agency: Datie e I of 3 Site Address: NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-IR, CF-IR-ADD, or CF-IR-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents and the applicable features shall be considered by all parties as minimum . component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all a #cablsections :tz the MF-IR Form with /arts: DESCRIPTION $ui(41tt )tpvelo Measures: _ ..._ 116 s 1: Doors and.windows between conditioned and unconditioned s es are manufactured to limit au i eA § 116(a)4: Fenestration products (except held-fulttcated windows) have a g label lt4llr `.the certified U-Factor, certified Solar Heat ixsin Coefficient ' Ri#C <:and infiltration that ril. the tc. uireineRt3.of: 107111`a, ,.117; Exterior doors and windows are ygoec 5tri , all.'ohits and etratioi s are caulked and sealed Insulations , :_cTfted.or installed meets Standards for Insulating Material Indicate and include on CF-6R Form thermal: emittance arid. solar reflectance values of the cool roofing material meets the requirements of § 1 I8 ) when:the rtsstt+ 140 of a Cool Rtnfis s , ' ified;:on the CF-1R Form. *§15� Minimum R-19 insulation in wood -frame coilft or o, uivaient U-factor., ')E Loose fill insulation shall conform. with manufacturer's installed desi labeled R-Value.. * 15Q( ;Minimum. R-13, insulation in wood -frame wall or uiai+ant U-fi[ctor #415l d): Minimum R-13 insulation in raised wood -frame floor or utYaii nt U-factor. O i,: Air rataM7n rs tars. Isiinlcd, and installed according; to ASTM E1677-9 when ified:on the CF-1R Form §2S _ ildtittdainry Va or barrier installed in Climate Zones 14 or 16 § 150(1) Water absorption rate for SIal3 edge insulation material alone ,*Wwut facings is no greater uran 0 3%; water vapor permeance rate is no ber than 2 0• ermlineh:and shal..1_be; rotecFd from: saeai,nama" e:and UV:Ii deterioration Fircptaces, Decoratiive Gas Appliances and Gas: Measures: §,150(e)l A: Masonry .11 or factorybuilt flre.places have u closable metal or glass door covering the entire opening of the firebox 150(e)IB: Masonry or factory4bullt ftep�css have a cainbusbon outside air intake, which is at least alit square inches in area and is equtppel with a wttli a teach/: actsaibie a ; le and tr t fitf and oi. a combust►on-air control device § 2 50(e)2 Guntrnuottg burning printdrghts and the use of indoor air for cooling;; a firebox jacket, t ben that indoor air is;vented to the qutside of the kiutlditi" ,are zohibitcd. _ ace Go7adiitl f i t' Water lxteafiu and `PIuntl 4k 5 stem Measures: . §1141' 113: HVAC . uiprrrtetrt:water heat. showerlteads faucets and all other regulated � hanees are certified b . the_E. Commission § 113(0) Water heating recirculation loops serving multiple dwelling<units and high-i{,ae residential orxtrpancies meet the air release valve, backflow etttitsn • U r isolation valve, and recirculation connection uircmonts of 1130 § 115: Ccurtiuuousiy-burning pilot lights are prohibited foenatural gas: fan -type central furnaces household cooking appliances (appliances with an that ecnsumc:less than 1.S0.Btu/hr are axcm . and 1 and's heaters. electrical su : vol.. connectionwitF i10t;1i --' § 15. ; } , klO and/or Mitt , loads are calculated in accordance with MHRAF,;SMACNA or ACCA §1S(1(i) Ileati stemx are ur 'with thermostats that meet the setback'teaaents of Section 112 b . Storage gas water heaters rated with an Energy Factor no greater than the federal:iiiitnttt O standard are extei�riully wrapped with insuladorr.I avin an installed thermal resistance ofR � 2 or §150(j)IB Unfrred.storage tanks, such as storage tanks or backup_tanks for solar wt4tcr-'heath system, or otheritidireCi;hot water:tatihave R-12 exztsttsal insulation or 946 internal. nsulatiait where the inteti A insulatcon R valise cs indicated on the ptterior of thetank.. First 5 feet of hot and cold water plow closest to water heater tank, 060 e, .. uiatitag systems; and entire length of GlibdI trng sections i1lL hi-N . of hot water i es are insulated r Standards Table 150 B _ l J ���"'`�- § I50)2 t'oitn$ system piping (suciiin, chilled water, or briute tines),a�ad; ptprii`insulated between`ldg sou land iitducet liotater tartk shall be tnstriated to Table 150-B sud.9 uatron 15(=A l �' t� /lt= § I50(i)2 I'tpe insulation for steam hydronic heating systems or hot water systems >15 p�i,2RtsAe1pgmr"errie of Standards fable 123-A. §150(j)3A Insulation is protecteght d from damage, including that due to sunl,rmoisture, equipment macntenanceand{wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines incf udees pqr retardant or is enclosed cetirely in condittioned space 2008 Residential Compliance Forms �Y August 2009 Malltdi tp Measures Sum. MF-1R _. Residential - 2 of 3 Site Address: Enforcement Agency: Date: §150(j)4: Solar wUtsC-lttii. r. ferns and/or collectors are certified 'the Solar iiati and Certification Ott tstttton . -Ducts :and Fans..Measures: 6150(m)lt All air -distribution system ducts and plenums installed, are sealed and rrtsttlatdti to meet the requirements of CMC Sections 601; 602, 6030.604, 605 and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL i8t UL :181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal 0 1 ter than 1/4 In* the combination of and either mesh or to .shall bc;uscd ---. 1:150(m)1* Building cavities, support platforms for air. hatidlet , and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air;: Building cavities and support platforms may contain ducts. Ducts installed in Cavities and siC rt:01. tfitreris shall ftUbe•Cotn : to cause iniiuctionxin-the cross -sectional -area: of the ducts. § 150(m)2D: Joints And seams of duct systems and their components shall not bdsealed with cloth back -rubberadhestveiduct tapes unless .Such tape is used in combination with mastic and draw bar► is §15: 9#} . Exhaust fan': `stet have back draft or automatic,dam §1SU itt 8 gravity voittilafi sterrris servi ' , 'conditioned S have either automatic or radii'. accessibleartarisaal . o d tuns Insulation shall be, front damage, taeludi # * due to sunlight, moisture, equipment maintenance, and wind» Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can +cause ale ationof the material: _. 150(en)10: Flexible ducts cannot have us mnec'cores. §1.50(o): All d )ling units shall meet the requupments of ANSI/ASHRAE Standard 62.2-2007' erttila an.and Acceptable Indoor:A.ir Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of -that Standard. PooIr and A a;Heatin" terns and i?".meint'Measures: §I14(a): Any posit or spa heating system shall be certified to have: a tEtettnitl effCtcucj�`that complies with the Appliance EfliciencyRegrtlatiions: an on -off switch mounted outside of the heater, a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance he3atiti or a, ilot lr ht § 114(b)l: Any pool or spa hcatirrg: equipment shall bo installed with at ,►cast 3fr' of pipe between filter and lteater, or dedicated suction and return Bite& .of built ,connections.for future solar...head . - ..... _- 11 )2; Outdoor is or a that have a heat turi or ' ; heater shall have a cover._ ef I. WOW.. Pools shall have dtrecki0tttti inlets that ujW,,rr mix the pool water, and a dine switch that willail .taw:nil:pumps to be set or med to Mn onl >durin -off, electric ilemrtrid::: odsr 150ifi)� , Residential ogl systems or u meet the :> s€yin -;flow rate, 1A ing,lbem and valve uittterslsof§lJ(1(p) Residential:: 4fin 'Measures ..... § 150(k) l : High efficacy luminaires or LED Light Engine With Integral Heat Sink has an efficacy that is no tower than theefficat tcs contained in Table I50-C and is not a low cfl"i a `: ; luminaire as .#1$0 The wattage of pt� installed luminaires shall be. determined as s tfiCd 150 ::Ballasts for fluorescent lam •rated 13 Watts or greatershall be electronic and shall have an:o tipprig no less than 20 kHz §150(k)5,: Permanently installed night lights and night lights i ttcglral to a,pemaanently l ts*llcd lumtnaire or exhaust dirt stall contain only high efficacy lamps meeting the minimum efficacies contained in Table .150-C and shall not contain a line -voltage socket or line -voltage lamp holder, OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw-bwesaClce€ l.c)d= i i :in to exhaust fans„ in rooms other than kitctie4 shall meet the licabie. ents of l . WOW All swit6ft devices and controls shall.meet the:..:,:.gtliremG#1tS §15Q(k)ii A minimum of 50 percent of the total rated Wattage of permanent) tttstailed l.'tg2ttulg kitchens shail:lie efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 f or 100 watts for dwelling:unrts larger than 2,500 f may be exempt from the 50°/u high efficacy requirement when: all low efficacy luminaires in.the.kitchen'<are controlled:byy manual_on occupant k �i IAi ate„ , K sensor, dimmer, energy management system (EMCS), or a multi -scene programmable.connttrol system;,and all permanently,installed luminaries ai-on in garages, nt sensor,dry rooms, closets greater than 70 square feet, and utility rooms are higlt,effcacy and�controlled by a § 150(ic)9: Permanently installed lighting that is interrral to csiiiinets shall use no more'thci 2tf�`vSatts� of poy��e`r�"rP,lria f illuminated cabinet § 150(k)IO Permanently installed lutrtitiaire+s in bathrooms, attached and dSaelecl. g a�gesraundry rooms, closets an .utility roomsshall be Itigit ctl•( _ iy _.. ___ Au t 2009 2008 Residential Compliance Forms Sr+s Mandatory Measures Sump Residential Site Address: .. .. Enforcement Agency: Date: controlled b a manual -on EXCEPTION I: Permanently installed low of caay luminaires shall be allowed prov>i. 04 that they.. y occupant sensor certified to comply with the applicable requirements of §.119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on p sensor•:: ... § 150(k)11: Permanently installed lurtiutprrs located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that.complies with the applicable requirements of § 119, or by a manual -on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with I!S0 k l•1< -. 150(k)12: Luminaires recessed LLinto insulated gclirigs shall be listed forzero clearance insulation contact (IC) by'Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing _.. and cells 150(k)13. Ltu inaixr providing outdoor lighting, includiriglightmg for pri :patios in low-rise residential t aildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (FMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to § 150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently. installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the W66raiaElectric:Code need ntit by-..,J"vffi=Y luminaires. 6150(k)14. internally tllumuiated address signs shall cotrtply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of wer as detormtined'.accordi ` to h3 d . 150 15: Light' for lots and carports with a total"of for 8 or more vehicles per slto shall comply with the applicable requirements in § (k)g8 ..P Sections "130, 132, .134, and 147:-Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of eatW 13t3 131 134and 146 §1 0(k)16: Permanently;inStalfed;it Etttti in the enclosed,.ttondvc+elting spaces of low-rise.tesfcle>dfiat buildings with four or more"dwCiling;umts shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensor(s) certified to j ( l vvi the**ltcabie " iir±Cin its"of 2008 Residential Compliance Forms Cl 0J `Q� UI TE.CEPFpPPROr 16E�6 �� DArE loN August 2009 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1 .............._.........._....._........... _.. . Project Title.......... Lennar Homes - Plan 1 Date..01/10/14 12:20:10 Project Address........ Belmont Collection ****** La Quinta, California *v8.1* Documentation Author- ,• Rick Maurer ****** Rick Maurer Title 24, Inc. 7544 E Saddlehill Trail Orange, CA 92869 714-771-1507 C1' tZone 15 imae ........... Compliance Method.......;. MICROPAS8 v8.1 for 2008 CEC Standards (r04) MICROPAS8 v8.1 File-LENNR1120 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 (Series I) ...... _. MICROPAS8 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/sf-yr) Design Design Margin Improvement Space Heating.... . . .._... 3.. 3 4.74 -1.41 -42.3 Space Cooling... 77.70" 72.18 5.60 7.2% Ventilation Fans. .....: Q..7, 0.61 0.00 0.0% Water Heating... 1:U 8.78 3.52 28.6% North Total 94...' 86.31 7.71 8.20 Space Heating...., �dM 3 3 5.39 a-2 06 -61.9% Space Cooling...:. 74.71 3:.07 4.0% Ventilation Fans: ..; O.f:1, 0.61 0.00 0.0% Water Heating.. 12.t' 8.78 3:52 28.6% ias't T.oa i4.. �4 4.53 4. 8% Space Heating... 3 33 5,58 -2.25 -67.6% Space Cooling.......... 7 ?Sl }72 `xi$ 5.69 7.3% Ventilation Fans_. 0 6;1 0. il. 0.00 0.0% _ Water Heating.... :....: 12 3`p 8 7 3.52 28.6% South Total 94.02 87.06 6.96 7.4% Space Heating......:...;;. 3.33 4.82 -1.49 -44.7% Space Cooling...:.:.::::::.:,.: 77.78 74.49 3.29 4.2% Ventilation Fans....,.>. 0.61 0.61 0.00 0.0% Water Heating.......;..; 12.30 8.78 3.52 28.6% West Total 94.02 88.70 5.32 5.7% *** Building complies with Computer Performance *** *** HERS Verification Required for *** �Compli�ce (, UlrVT 4ppRETy DEP� ED LrE CTIQN Electronically Signed-at,Ct EERS.0utn by James Jenike (Lennar Homes) - 1/10/2014 4:20:17 PM Electronically Filed by RickMa` -ter=d Authenticated at CHEERS.com - 01 /10/2014 01:37 PM Registered with CHEERS on U10014 1.37,-p PM • Registration Number: 413-N001297513-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 ?roject Title;. ,:.....:, ;;<.:: Lennar Homes Plan 1 Date.. ul/ lD/ 14 16:60: 1D MICROPAS8 v8.1 File-LENNR1120 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 (Series I) GENERAL INFORMATION HERS Verification..... Required Conditioned Floor Area....:: 2967 sf Building Type .... .:.;...«:..>: «::.= Single Family Detached Construction Type ......... New Natural Gas at Site ....... Yes Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.,.,,, Slab On Grade Number of Building Zones;;:.:. 1 Conditioned Volume .«.. .... 32637 cf Slab -On -Grade Area .;«: .:.;:..; 2967 sf Glazing Percentage.;;.R.-.. 19.7 % of floor area Average Glazing U-factor-.._ 0.35 Btu/hr-sf-F Average Glazing SHGC., 0;.25 Average Ceiling Height 11 ft BUILDI&G,r, I-NFORMATION Floor # of #�6' bond- Thermo- Vent Vent Verified Area Volume Dwell Petit it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap Residence 2967 32637 1 %Q0, ae'k: 2.0 Standard No t. y AST I C' AND ROO`FETAT Roof i:oc>� Emiss- Frame Spac- Value Value Vent Mass Rise Elect- ivity Depth ing Above Below Area Vent Roof Type (lb/sgft) aTt'e. (in.) (in.) Deck Deck Ratio High .:.. .....:::: Tile Heavy 3:12 0.16 0.89 3.5 24 oc 0.00 0.00 1/300 0.30 UI � �� LA LNG ,SAFE ��NTA 4ppFj V� QEpT COMSTRUCTf0 DATE ,. to°by James 7enike (Lennar Homes) - 1/10/2014 4:20:17 PM Electronically Signed at Ql 'ti Electronically Filed by Rtck. MAttrt r' Authenticated at CHEERS.com - 01/10/2014 01:37 PM Registered with CHEERS on 1tkORL41413735 PM °Registration Number: 413-N001297513-OO 00000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-111 Page 3 Project Title. Lennar mutes - rtaii t MICROPAS8 v8.1 File-LENNR1120 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 (Series I) OPAQUE SURFACES U- Sheath - Frame Area fact- Cavity ing Act Surface Type (sf) or R-val R-val Azm Tilt 1 Wall Wood 302 0.069 21 0 0 90 2 KneeWall Wood 64 0.069 21 0 0 90 3 Wall Wood 289 0.069 21 0 0 90 4 Wall Wood 469 0.069 21 0 90 90 5 Wall Wood 110 0.095 15 0 90 90 6 Wall Wood 527 0.069 21 0 180 90 7 Wall Wood 528 0.069 21 0 270 90 8 KneeWall Wood 64 0.069 21 0 270 90 9 AtticRad Wood 2967 0.025 38 0 n/a 0 10 Door Wood 24 0.500 0 0 0 90 11 Door Wood 21 0.500 0 0 0 90 Orientation 1 Wind Front (N) 2 Wind Front (N 3 Wind Front (N); 4 Wind Front (N) 5 Wind Front (N). 6 Wind Left (E)_ 7 Wind Left (E)'' 8 Wind Back (S):. 9 Wind Back (S) 10 Door Back (S) 11 Wind Back (S) 12 Door Back (S) 13 Wind Back (S)' 14 Wind Back (S:) 15 Wind Right (W) PERIMETER LOSSES olar Appendix ains JA4 Location/ Reference Comments Yes 4.3.1 A6 Front 2x6 Wall Yes 4.3.1 A6 Attic KneeWall No 4.3.1 A6 Gar. 2x6 Wall Yes 4.3.1 A6 Left 2x6 Wall No 4.3.1 A4 Gar. Wall Yes 4.3.1 A6 Back 2x6 Wall Yes 4.3.1 A6 Right 2x6 Wall Yes 4.3.1 A6 Attic KneeWall Yes 4.2.1 A21 Vented Attic Yes 4.5.1 A4 Front Door No 4.5.1 A4 Garage Door FENESTRATION SURFACES Area 'U- (sf) factor SHGC Azm Tilt Type Location/Comments 18.0 0.350 0.250 0 90 Standard FGLASSI 24.0 0.350 0.250 0 90 Standard FGLASS2 18.0 0.350 0.250 0 90 Standard FGLASS3 15.6 0.350 0.250 0 90 Standard FGLASS4 36.0 0.350 0.250 0 90 Standard FGLASS5 24.0 0.350 0.250 90 90 Standard LGLASSI 24.0 0.350 0.250 90 90 Standard LGLASS2 27.5 0.350 0.250 180 90 Standard BGLASSI 15.0 0.350 0.250 180 90 Standard BGLASS2 80.0 0.350 0.250 180 90 Standard BGLASS3 36.0 0.350 0.250 180 90 Standard BGLASS4 192.0 0.350 0.250 180 90 Standard BGLASS5 4.5 0.350 0.250 180 90 Standard BGLASS6 18.0 0.350 0.250 180 90 ['tt--,GLASS? 36.0 0.350 0.250 270 90ti��5�1�_ BV/LD/NG &7 QJ/N-r A ®Ep-r 4 CO F'OVED STR'JCT/OP J DArE BY Electronically Signed UCHEEW;W cam by 191t t Jenike (Lennar Homes)-1/10/2014 4:20:17 PM Electronically Filed by Rick ii4attt& di aluthenticated at CHEERS.com - 01/10/2014 01:37 PM Registered with CHEERS on 1/10"14 13? 3S 1'M' Registration Number. 413-N0012975B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 ,roject Title. Lennar nUIIteS r.Lctii 1 1jat-c..v1/ LVI y= iG.Gv. iv MICROPAS8 v8.1 File-LENNR1120 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 (Series I) FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments .... .. ....... 16 Wind Right (W) 8.0 - 0.350 0.250 270 90 Standard RGLASS2 17 Wind Right (W) 8.0 0.350 0.250 270 90 Standard RGLASS3 OVERHANGS Window Overhang _ Area Left" Right Surface (sf) Width Height Depth Height Extension Extension 1 Window 18.0 n/a .. ...... 6.0 1.5 4.0 n/a n/a 2 Window 24.0 n/a 6.0 4.7 1.0 n/a n/a 3 Window 18.0 n/a 6.0 .4.-7 1.0 n/a n/a 4 Window 15.6 n/a 6.7 7.5 0.0 n/a n/a 5 Window 36.0 n/a 6 0 1.0 0.3 n/a n/a 7 Window 24.0 n/a 6 0_,` 4 0 - '1.0 n/a n/a 9 Window 15.0 n/a 1 510\(3 1.0 n/a n/a 10 Door 80.0 n/a 8 0. ;.: 10 3 a 3. 0 n/a n/a 11 Window 36.0 n/a 1.5 1.0 n/a n/a 12 Door 192.0 n/a 8.0 1Q`=<3 3.0 n/a n/a 13 Window 4.5 n/a 1.5 A .. 3 1.0 n/a n/a 14 Window 18.0 n/a 6.0 1-0.-3 3.0 n/a n/a 15 Window 36.0 n,/a 60 ya1 5�,�0 ., n/a n/a 16 Window 8.0 n%a 40 1 :S 4 = n/a n/a 17 Window 8.0 n%:a '4 0 - 1.5 _ U' n/a n/a Area Slab Type (sf) Standard Slab 2967 HVAC SYSTEMS Verified Verified Verified Verified Verified Maximum System Minimum Refrig Charge Adequate Fan Watt Cooling Type Efficiency EER or CID Airflow Draw Capacity Furnace 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 13.00 SEER 11.5 No �I No No No Buy Q OF IA C��JI �� & SAFETY of A 4ppROVED NSrRUC7'ION DATE BY Electronically Signed at CHEERS.com by James Jenike (Lennar Homes)-1/10/2014 4:20:17 PM Electronically Filed by Rick Maurer and Authenticated at CHEERS.com - 01/10/2014 01:37 PM Registered with CHEERS on 1/l0/2014 1:37:35 PM ; Registration Number: 413-N0012975B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5 Project Title.......... Lennar Homes - Plan 1 Date..01/10/14 12:20:10 .......... MICROPAS8 v8.1 File-LENNR1120 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 (Series I) HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr) Furnace 49428 n/a n/a n/a ACSplit n/a 36709 45556 n/a Orientation of Maximum....: Sizing Location.. ..,. . Winter Outside Design.. Winter Inside Design...::,,.: Summer Outside Design..,.:. , Summer Inside Design...,..,,:. Summer Range..... Front Facing 270 deg (W) LA QUINTA 26 F 70 F 111 F 75 F 34 F w" DiiGT : SY8<'�EMS Verified Verified Verified System Duct D cC.;, Duct Surface Buried Type Location R vae Leakage Area Ducts Furnace Attic R46' Yes No No ACSplit':trc. R-6 Yes No No Flow Power (fcfm) .axE' t�W/cfm) .......::::..:: Standard 59.67 .25 WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value _. 1 Smalllnstanta Gas Recirc/DemandManual 1 .82 n/a R-n/a CI Fy OF LA QtjjN7' BUILDING & SAFEA TY pEpT Fp p pRo�!I�i� SrRUCTION. DATE-` BY I Mttc tantesl�y1tgg�n.ed at CHEERS.com by lamb, Anikt (Lenmar Homes) - 1/10/2014 4:20:17 PM 066:6t Mig1 ., 1'[ed by Rick Maurer anti Auf1 C,gitC&i at CHEERS.com - Ol/10/2014 01:37 PM Rcgiot *I tt ctlaw;on 1/10/20141:37 35 PM Registration Number: 413-N0012975B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6 Project Title Lennar Homes Plan 1 Date..01/10/14 12:20:10 MICROPAS8 v8.1 File-LENNR1120 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 (Series I) SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. This building incorporates a Cool Roof. This building incorporates a non-standard Water Heating System. HERS REQUIRED VERIFICATION *** Items in this section *** verification by a cer *** the supervision of a. *** CEC approved testing.: *** must be reported on ti This building incorporates HERS ve ield testing and/or *** e energy rater under *** ed HERS provider using *** fication methods and *** nstallation certificate. *** igh Energy Efficiency Ratio (EER). This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R J the measured CFM is above the target, then corrective tion mustbe k rlo reduce the duct leakage and ac then must be retested. Alternatively, tide +otliance calculations could be redone without duct testing. If dtcts, aze not installed, then HERS verification is not necessary..>F=.. E i & ;x :'°`_ REMARKS 1) This house will have Cool Roof rated concrete tiles with .16 minimum aged reflectance and .89 minimum emissivity. 2) All hot water lines will be insulated per Sec. 150(1) with a minimum of 1 inch insulation. This is an addition to the insulation required by the mandatory requirements. 3) The water heater for this house will have a hot water demand type recirculating system with manual control. 4) This house will have a tankless water heater with an energy factor of .82 or greater and sized per the owner's specifications, t �-e13� 5) All windows and glass doors will have non-metal_ fram}esP with a weighted average NFRC U-factor of 136' jqr -less andJafQ1 j1 � rAB� weighted average SHGC of .25 or less with! high``perfo inagrze eV `���Y OEA7; 40RPCP0N'R,S07RtVjCCD ON DATE BY Electronically Signed at CHEERS.com by James Jenike (Lennar Homes)-1/10/2014 4:20:17 PM Electronically Filed by Rick Maurer and Authenticated at CHEERS.com - 01/10/2014 01:37 PM Registered with CHEERS on 1/10/2014 1:37:35 PM • Registration Number. 413-N0012975B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-IR Page 7 .. Project Title..... Lennar Homes Plan 1 Date..01/10/14 12:20:10 MICROPAS8 v8.1 File-LENNR1120 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 (Series I) ,4 Low-E (Max) glass. REMARKS __......._. _ ........ COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. Name.... Company. Address. Phone ... License:. Signed. ;: Name.... Title Agency.. Phone.:... DESIGNER or OWNER,,; Lennar Homes'`ny= 980 Montecito Drive,#3'02dress.. Corona, CA 92879- (951) 817-3565 :Phone... . ENFORCEMENT AGENCY DOCUMENTATION AUTHOR Rick Maurer Rick Maurer Title 24, Inc.. 7544 E Saddlehill Trail Orange, CA 92869 714-771-1507 () ..w. (date) Signed... ............ (date) LA D/N(& SAF E� lo j_rq APPR DEp-r. FOR CONSO V&OND SATE �— gy Electronically Signed at CHEERS.com by James Jenike (Lennar Homes)-1/10/2014 4:20:17 PM Electronically Filed by Rick Maurer and Authenticated at CHEERS.com - 01/10/2014 01:37 PM Registered with CHEERS on 1/10/2014 1:37:35 PM • Registration Number: 413-NO01297SB-000000000-M R HVAC SIZING HVAC Page 1 �--- - Project Title.......... Lennar Homes - Plan 1 Date..01/10/14 12:20:10 Project Address........ Belmont Collection ****** La Quinta, California *v8.1* Documentation Author... Rick Maurer Building Permit # ****** Rick Maurer Title 24, Inc. 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Check/ Date Climate Zone.. .. 15 Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r04) MICROPAS8 v8.1 File-LENNR1120 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 (Series I) GENERAL INFORMATION Floor Area........... ................ 2967 sf Volume ......................;:. 32637 cf Front Orientation...........:»,:. Front Facing 0 deg (N) Sizing Location.......:..;_.«:«« LA QUINTA Latitude ..............«« 33.8 degrees Winter Outside Design...:...: 26 F Winter Inside Design.. ...«.:: 70 F Summer Outside Design.,,.. 111 F Summer Inside Design.. : 75 F Summer Range .......... :.::,:,:» 34 F Interior Shading Used,,;:, :.::,., Yes Exterior Shading Used,....:..:,; Yes Overhang Shading Used.,..... »..:; Yes Latent Load Fraction....... 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 23986 10978 Glazing Conduction and Solar..... 9003 10485 Infiltration ..................... 9648 5578 Internal Gain .................... n/a 2520 Ducts ............................ 6792 5368 Sensible Load .................... 49428 34929 Latent Load ...................... n/a 8418 Minimum Total Load f _,_�;9 28--__ 43347 Note: The loads shown are only one of the criPtfe��gNafgettAi g�,t, hd-rs ection of HVAC equipment. Other relevant design factors such-Tya-s- a r flow 04 requirements, outside air, outdoor design t.-e�ymYpe.ra�turre's,; coil • sizing, availability of equipment, oversizing sa ety k rg. 4,4S-etc.,Elmust also be considered. It is the HVAC designer's esponsibility t0 1_l(consider all factors when selecting the HVAC equipment DATE _i BY HVAC SIZING HVAC Page 2 ....... Project Title .......... Lennar Homes Plan 1 Date..01/10/14 12:20:10 _.... MICROPAS8 v8.1 File-LENNR1120 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 (Series I) GENERAL INFORMATION Floor Area..... . .. 2967 sf Volume..... .«K... 32637 cf Front Orientation.......... Front Facing 90 deg (E) Sizing Location............ LA QUINTA Latitude=:: ... ...... 33.8 degrees Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F Interior Shading Used........ Yes Exterior Shading Used.:..,... Yes Overhang Shading Used.,...... Yes Latent Load Fraction....... 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 23986 10946 Glazing Conduction and Solar..... 9003 11996 Infiltration....:.. .... .,,... 9648 5578 Internal Gain .................... n/a 2520 Ducts ............................ 6792 5637 Sensible Load .................... ........49428 36677 Latent Load ...................... n/a 8839 Minimum Total Load 49428 45517 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. C; RUILD1 G & ,S f E TA ��pR��N DEPT. DR CONSO ED ON DATE BY J HVAC SIZING HVAC Page 3 __. Project Title.......... Lennar Homes - Plan 1 Date..01/10/14 12:20:10 ................ MICROPAS8 v8.1 File-LENNR1120 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title_24, Inc Run -Plan 1 (Series I) GENERAL INFORMATION Floor Area ................. 2967 sf Volume ..................... 32637 cf Front Orientation.......... Front Facing 180 deg (S) Sizing Location............ LA QUINTA Latitude ................... 33.8 degrees Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... Ill F Summer Inside Design....... 75 F Summer Range ............... 34 F Interior Shading Used...... Yes Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 23986 10972 Glazing Conduction and Solar..... 9003 10484 Infiltration ..................... 9648 5578 Internal Gain .................... n/a 2520 Ducts ............................ 6792 5367 Sensible Load .................... 49428 34922 Latent Load ...................... n/a 8416 Minimum Total Load 49428 43338 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. � r QU/LDi �� LA��1 1r 41'�PROVI��E) & SAFE, DEPr. uCTION DprE _� BY HVAC SIZING HVAC Page 4 ...... _. ..__ Project Title .......... Lennar Homes Plan 1 Date..01/10/14 12:20:10 . ....... _ _ MICROPAS8 v8.1 File-LENNR1120 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 (Series I) GENERAL INFORMATION Floor Area.... _ 2967 sf Volume .......... 32637 cf Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ LA QUINTA Latitude..: - - 33.8 degrees Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range. ;..... 34 F Interior Shading Used...... Yes Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 23986 10974 Glazing Conduction and Solar..... 9003 11996 Infiltration ..................... 9648 5578 Internal Gain .................... n/a 2520 Duets,:; .:..:...... « .a...., .......... ,.., 6792 5642 ... ._......... Sensible Load .................... 49428 36709 Latent Load ...................... n/a 8847 Minimum Total Load 49428 45556 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. APpp®� KEPT. �R CONSTRV ED ON DATE �� BY f CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1 Project Title.........:. Lennar Homes-#1 w/Casita Date..01/10/14 12:24:06 Project Address...... Belmont Collection ****** La Quinta, California *v8.1* Documentation Author..: Rick Maurer ****** Building Permit # Rick Maurer Title 24, Inc. 7544 E Saddlehill Trail Plan Check Date Orange, CA 92869 714-771-1507 Field Checkl Date Climate Zone............_. 15 -- Compliance Method......., MICROPAS8 v8.1 for 2008 CEC Standards (r04) MICROPAS8 v8.1 File-LENNR1121 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) MICROPAS8 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/sf-yr) Design Design Margin Improvement Space Heating...,, _ 3 8:Q 5.03 -1.23 -32.4% Space Cooling.... 78 54 76.41 2.13 2.7% Ventilation Fans. .. 0 +E5 0.65 0.00 0.0% Water Heating. .._.,« . « ... lx 1'� 7.36 3.79 34.0% North Total 94' 1,<4 , 89.45 4.69 5. 0 Space Heating..... 5.66 -1.86 -49.0% Space Cooling ..... ...«. 7,8«54 79.40 -0.86 -1.1% Ventilation Fans......;..?:,«6.5. 0.65 0.00 0.0% Water Heating...... 7.36 3.79 34.0% East Total 93�07 1.07 1.1% Space Heating........ 3.0` 5.86 -2.06 -54.2% Space Cooling......... 2.48 3.2% Ventilation Fans....... :{.65' 0,,65: 0.00 0.0% Water Heating.... 11 15 7.36 3.79 34.0% South Total 94.14 ..::-:. ...L..., 89.93 4.21 4.5% Space Heating...,;.....:;:. 3.80 5.16 -1.36 -35.8% Space Cooling....,..,.:.:,., 78.54 78.87 -0.33 -0.4% Ventilation Fans...:.«..:«: 0.65 0.65 0.00 0.0% Water Heating... 11.15 7.36 3.79 34.0% West Total 94.14 92.04 2.10 2.2% *** Building complies with Computer -Performance *** ** *** HERS Verification Required fort Comp a°noe BD�LDfN(3� 5 FQUA A F��/� DEpT O R CONS0 EjJ DATE N _ BY Electronically Signed at CHEERS.com by James Jenike (L.ennar Homes) - 1/10/2014 4:21:01 PM Electronically Filed by Rick Maurer and Authenticated at CHEERS.com - 01/10/2014 01:38 PM Registered with CHEERS on 1/10/20141:38:44 PM * Registration Number: 413-N0012976B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2 v........._JLI If, ;n+e 1)111n11A 17.7a.n9 'rOjecL llt le. e > . LCnnal 11VLRG.0 1-ff w/ � _ +�•+�� ivi i i . � .. MICROPAS8 v8.1 File-LENNR1121 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) GENERAL INFORMATION HERS Verification....;.:.;....::• ,, Required Conditioned Floor Area..... 3271 sf Building Type ............... Single Family Detached Construction Type ......... New Natural Gas at Site ....... Yes Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.:.....; Slab On Grade Number of Building Zones::;:>, 2 Conditioned Volume...... 35373 cf Slab -On -Grade Area.......,; 3271 sf Glazing Percentage........: 20.1 % of floor area Average Glazing U-factory.:. 0.35 Btu/hr-sf-F Average Glazing SHGC.. 0.25 Average Ceiling Height :' 10.8 ft BUILDING '6w -INFORMATION Floor # of #ofCond- Thermo- Vent Vent Verified Area Volume Dwell Peop,-, it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap HOUSE Residence 2967 3263Q E) 1 _" A 6 Y 6 t 71Setbao k.. 2.0 Standard No CASITA �. Residence 304 2736 0.09 0.5 Yes Setback 2.0 Standard No ATTIC AND ROOF DETAILS Frame R- R- Roof Roof Re- Emiss- Frame Spac- Value Value Vent Mass Rise flect- ivity Depth ing Above Below Area Vent Roof Type (lb/sgft) ance (in.) (in.) Deck Deck Ratio High HOUSE Tile Heavy 3:12 0.16 0.89 3.5 24 oc 0.00 0.00 1/300 0.30 CASITA Tile Heavy 3:12 0.16 0.89 3.5 24 oc 0.00 0.00 1/300 0.30 C6T�' ®F DC -PT FO P O O VCD STRUCDON DATE BY Electronically Signed AtC_jgW mitt by dazes Jenike (Lennar Homes)-1/10/2014 4 21:01 PM Electronically Filed by Riali;%Uwarettd Attihei%ticated at CHEERS.com - 01/10/2014 01:38 PM Registered with CHEERS on i!1(1kt01�i 13" FM 44kegistration Number: 413-N0012976B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3 Drn-lcnt m; 1-lc - T.Pnnar Hnmas-*l w/Casita Date--01/10/14 12:24:06 MICROPAS8 v8.1 File-LENNR1121 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains JA4 Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments HOUSE 2 Wall Wood 302 0.069 21 0 0 90 Yes 4.3.1 A6 Front 2x6 Wall 3 KneeWall Wood 64 0.069 21 0 0 90 Yes 4.3.1 A6 Attic KneeWall 4 Wall Wood 289 0.069 21 0 0 90 No 4.3.1 A6 Gar. 2x6 Wall 6 Wall Wood 469 0.069 21 0 90 90 Yes 4.3.1 A6 Left 2x6 Wall 7 Wall Wood 110 0.095 15 0 90 90 No 4.3.1 A4 Gar. Wall 9 Wall Wood 527 0.069 21 0 180 90 Yes 4.3.1 A6 Back 2x6 Wall 11 Wall Wood 528 0.069 21 0 270 90 Yes 4.3.1 A6 Right 2x6 Wall 12 KneeWall Wood 64 0.069 21 0 270 90 Yes 4.3.1 A6 Attic KneeWall 13 AtticRad Wood 2967 0.025 38 0 n/a 0 Yes 4.2.1 A21 Vented Attic 15 Door Wood 24 0.500 0 0 0 90 Yes 4.5.1 A4 Front Door 16 Door Wood 21 0.500 0 0_ 0 90 No 4.5.1 A4 Garage Door CASITA 1 Wall Wood 156 0.095 15 0 0 90 Yes 4.3.1 A4 Front Wall 5 Wall Wood 127 0.095 15i 90 90 Yes 4.3.1 A4 Left Wall 8 Wall Wood 140 0.095 15' =180 90 Yes 4.3.1 A4 Back Wall 10 Wall Wood 135 0.095 15 . i{' ' `270 90 Yes 4.3. 1 A4 Right Wall 14 AtticRad Wood 304 0.025 38 a0 ;..._n/a 0 Yes 4.2.1 A21 Vented Attic PERIMETER LOSSES Length F2' tiul Appendix Solr ,A4 Location/ Surface (ft) i Far it 1. i ns Veference Comments HOUSE 17 S1abEdge 266 0.730 R-0/Oin No 4.4.7 Al Standard Slab Edge CASITA 18 SlabEdge 70 0.730 R-0/Oin No 4.4.7 Al Standard Slab Edge FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments HOUSE 1 Wind Front (N)' 18.0 0.350 0.250 0 90 Standard FGLASSI 2 Wind Front .(N;) 24.0 0.350 0.250 0 90 Standard FGLASS2 3 Wind Front ;(N) 18.0 0.350 0.250 0 90 Standard FGLASS3 4 Wind Front 15.6 0.350 0.250 0 90 Standard FGLASS4 5 Wind Front (N) 36.0 0.350 0.250 0 90 Standard FGLASS5 7 Wind Left (E) 24.0 0.350 0.250 90 90 Standard-LGLASS_1 8 Wind Left {E) 24.0 0.350 0.250 90 90 St;a"n'dardtLGLASS2, ILDIN(3 'I�� 1NTA FO ppnov� CEP7; CONSTRUCTIO I)Ar-�� sY Electronically Signed rit CHEERS 00#i by James Jenike (Lennar Homes) -1 /10/201-4 4,21 Electronically Filed bbyy Ri&dr Maunx:and Authenticated at CHEERS.com - 01 /10/2014 01 Registered with CHEERS on7/ifl/201413g 44 PM * Registration Number: 413-N0012976B-N CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 Project rule. LenllclL nulneS-Tt.L w/%-asl.ia MICROPAS8 v8.1 File-LENNR1121 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments . :....:::: 10 Wind Back {S) 27.5 0.350 0.250 180 90 Standard BGLASSI 11 Wind Back IS) 15.0 0.350 0.250 180 90 Standard BGLASS2 12 Door Back �S) 80.0 0.350 0.250 180 90 Standard BGLASS3 13 Wind Back (S) 36.0 0.350 0.250 180 90 Standard BGLASS4 14 Door Back IIS) 192.0 0.350 0.250 180 90 Standard BGLASS5 15 Wind Back 'S) 4.5 0.350 0.250 180 90 Standard BGLASS6 16 Wind Back -S.) 18.0 0.350 0.250 180 90 Standard BGLASS7 18 Wind Right �(W) 36.0 0.350 0.250 270 90 Standard RGLASSI 19 Wind Right {W) 8.0 0.350 0.250 270 90 Standard RGLASS2 20 Wind Right ,W) 8.0 0.350 0.250 270 90 Standard RGLASS3 CASITA 6 Wind Front (9 24.0 0.350 0 I5 O 90 Standard FGLASS6 9 Wind Left (E°°:) 8.0 0.350 D 90 Standard LGLASS3 17 Door Back ,S,),' 40.0 0.350 0 25W „-90 Standard BGLASS8 S -Window -Overhang x, Area Left Right Surface (sf) Width Height Depth Height Extension Extension HOUSE . 1 Window 18.0!� 1.5 4 U n/a n/a 2 Window 24.0 a<1st f 0 4.7'` 1.0 n/a n/a 3 Window 18.0 n/a 6 D 4.7 1,0 n/a n/a 4 Window 15.6 ri%a C g'� s "` 7:-`5 00 €':' n/a n/a 5 Window 36.0 n/a 6.0 1.0 0.3 n/a n/a 8 Window 24.0 n/a 6.0 4.0 1.0 n/a n/a 11 Window 15.0 n/a 1.5 10.3 1.0 n/a n/a 12 Door 80.0 n/a 8.0 10.3 3.0 n/a n/a 13 Window 36.0 n/a 1.5 10.3 1.0 n/a n/a 14 Door 192.0 n/a 8.0 10.3 3.0 n/a n/a 15 Window 4.5 n/a 1.5 10.3 1. n/a n/a 16 Window 18.0 n/a 6.0 10.3 3.0 n/a n/a 18 Window 36.0 n/a 6.0 1.5 2.0 n/a n/a 19 Window 8.0 n/a 4.0 1.5 2.0 n/a n/a 20 Window 8.0 n/a 4.0 1.5 2.0 n/a n/a CASITA 6 Window 24.0 n/a 6.0 2.0 0.3_ n/a n/a Cl 8(jfLa-YIN& ,,A C J1 1' /k �,�,�wreTy D EP A GR CONSoVPn DATE TipN Electronically Signed at CHEERS.com by James Jenike (L,ennar Homes) - 1/10/20144:21:01 PM Electronically Filed by Rick Maurer and Authenticated at CHEERS.com - 01/10/2014 01:38 PM Registered with CHEERS on 1/10/2014 1:38:44 PM' Registration Number. 413-N0012976B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5 Project Title.. '«; Lennar nUmes-tti w/casria uate..v1/1v/1z 1c.. c.z.vv MICROPAS8 v8.1 File-LENNR1121 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) SLAB SURFACES Area Slab Type (sf) HOUSE Standard Slab 2967 CASITA Standard Slab 304 HVAC SYSTEMS Verified Verified Verified Verified Verified Maximum System Minimum Refrig Charge Adequate Fan Watt Cooling Type Efficiency EER or CID Airflow Draw Capacity _ ....:.. HOUSE Furnace 0.800 AFUE zfa 'l/;A n/a n/a n/a ACSplit 13.00 SEER No No No CASITA HPSplit 7.70 HSPF n aj n/a n/a n/a ACSplit 13.00 SEER 11 0 NQ No No No i�%;SIZ`TNC', Verified �atal Sext.�b� e Design a Ila G;ocs%i�n C t al tg e° Maximum Cooling System Pad Lodd C.peaty Capacity Type jBtuh) (Btu/hr) (Btu/hr) E. (Btu/hr) HOUSE Furnace 49428 n/a n/a n/a ACSplit n/a 36688 45530 n/a CASITA HPSplit 8954 n/a n/a n/a ACSplit n/a 6049 7507 n/a Total 58382 42738 53038 n/a Orientation of Maximum.._..;.. Sizing Location......... ............. Winter Outside Design...;:%.. Winter Inside Design.....:.. Summer Outside Design........ Summer Inside Design....;.::;: SummerRange ............... Front Facing 270 deg (W) LA QUINTA 26 F 70 F 7�5 �FAI 3 4 F' SUILDI G & .'Q(J1NT 4PR01'EDR �SAFE7yDEp-Dp7-E RUCTI °N t� BY Electronically Signed at CHEERS dit by la s Jenike (Lennar Homes)-1/1OR014 421:01 PM Electronically Filed by',ikiGk 14t. " ttnd Aittlienticated at CHEERS.com - 01 /10/2014 01:38 PM Registered with CHEERS on l/Ift�2014 l 38 44 k. *Registration Number: 413-N0012976E-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6 ................ ?roject Title:,::,:.,;.Lennar Homes-# ! w/uasita Date.. U1/ lU/ 14 1L :G4 : UC MICROPAS8 v8.1 File-LENNR1121 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) DUCT SYSTEMS Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R-value Leakage Area Ducts HOUSE Furnace Attic R-6 Yes No No ACSplit Attic R-6 Yes No No CASITA HPSplit Attic R-6 Yes No No ACSplit Attic R-6 Yes No No FAN SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distributi�rr . System Factor (gal) R-value ......... 1 5ma11Instanta Gas RecirC/DemandManual 2.82 n/a R-n/a SPECIA°I;=fFEATURES' LAND MODETING`PSSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. This building incorporates a Cool Roof. This building incorporates a non-standard Water Heating System. �� OF �UIC�1�iG�' sAF LA �'j� A Ely Fo � � ��}�� QEPT N TRUCTr�J DATE �-- 8y Biaetr06ictall�yS at CHEERS.com by James Jenike (Lennar Homes) -1/10/2014 4:21:01 PM l:C4ctroniGal3I E by Rick Maurer and Authenticated at CHEERS.com - 01/10/2014 01:38 PM RegistCt lwith.CHEiRSpKt 1/10/20141:38:44 PM * Registration Number: 413-N0012976B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7 ... Project Title. .,.,: Lennar Homes-#1 w/Casita Date..01/10/14 12:24:06 MICROPAS8 v8.1 File-LENNR1121 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified High Energy Efficiency Ratio (EER). This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. Ji €, 1) This house will have Cool Roofrat4ed concrete tiles with .16 minimum aged reflectance and:89 minimum emissivity. 2) All hot water lines will be insulated per Sec. 150(J) with a minimum of 1 inch insulation ,This "is an addition to -;. the insulation required by the mandatory requirements. 3) The water heaters for this house will have a hot water demand type recirculating systemwith,manual control. wo tankles°s water heaters with an 4) This house will. haveit energy factor of .82 r'greatek and a°s zed perAhe owner's specifications. 5) All windows and glassy door<s) will have -non4m6til frames with a weighted average NFRC U-factor of .35 or less and a weighted average SHGC of .25 or less with high performance Low-E (Max) glass. r �QF LA � G & SAP Qt.J/NTA r PFJo °Epr R CO NSTR V oarE SON gy Eleetr m Sited at CHEERS.com by James Jenike (Lennar Homes) - MW2014 4:21:01 PM E(Cct(o�tt�y t'-11ed by Rick Maurer and Authenticated at CHEERS.com - 01110/2014 01:38 PM Registei�tr�•`on 1/10/2014 1:38.44 PM • Registration Number: 413-N00129704M0000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 8 Project Title.......... Lennar Homes-#1 w/Casita Date..01/10/14 12:24:06 MICROPAS8 v8.1 File-LENNR1121 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... ......... Name.... Rick Maurer Company. Lennar'Homes Company. Rick Maurer Title 24, Inc. Address. 980 Montecito Drive,#302 Address. 7544 E Saddlehill Trail Corona, CA 92879 Orange, CA 92869 Phone... (951) 817-3565 Phone.:. 714-771-1507 License. Signed.. _...._. Signed..;. , ,,, ,;,�. ,,. .; Ihoh y �.t ENFORCEMENT AGENCY Q SO1LQ1'VG& L QUINTA 40RPCPONR,SOVCD CPTTRV OgTE ON By Electronically Signed at CHEERS.com by James Jcnike (L.ennar Homes) - 1/10/2014 4:21:01 PM Electronically Filed by Rick Maurer and Authenticated at CHEERS.com - 01/10/2014 01:38 PM Registered with CHEERS on 1/10/20141:38:44 PM " Registration Number: 413-N0012976B-000000000-0000 HVAC SIZING HVAC Page 1 ......... Project Title.......... Lennar Homes-#1 w/Casita Date..01/10/14 12:24:06 Project Address........ Belmont Collection ****** La Quinta, California *v8.1* Documentation Author... Rick Maurer ****** Building Permit # Rick Maurer Title 24, Inc. 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Check/ Date Climate Zone....... .. 15 Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r04) ........... -- MICROPAS8 v8.1 File-LENNR1121 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) GENERAL INFORMATION Floor Area ................. 3271 sf Volume .................... 35373 cf Front Orientation«....«. ... -..«,,Front Facing 0 deg (N) Sizing Location ............ ,. LA QUINTA Latitude .................... 33.8 degrees Winter Outside Design..:..... 26 F Winter Inside Design....._.,.:. 70 F Summer Outside Design....... ..111 F Summer Inside Design.._..::.... 75 F Summer Range......... ;._ 34 F Interior Shading Used... Yes Exterior Shading Used.."i, .Yes Overhang Shading Used. ,.;.Yes Latent Load Fraction.. .«;,, «;.;«; 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 29611 13283 Glazing Conduction and Solar..... 10112 11733 Infiltration ..................... 10637 6150 Internal Gain.....,. _, n/a 2750 Ducts ............................ 8022 6159 Sensible Load .................... 58382 40075 Latent Load ...................... n/a 9658 Minimum Total Load '583.8.2'7--__ 49733 Note: The loads shown are only one of the cr of HVAC equipment. Other relevant desi requirements, outside air, outdoor design availability of equipment, oversizing safe considered. It is the HVAC designer's reds factors when selecting the HVAC equipment. R fa y marg not onsibility Lg� t�hU Aheco0w 6hic�as_ air A flow also be der all F `� BY HVAC SIZING HVAC Page 2 __.... Project Title.......... Lennar Homes-#1 w/Casita Date..01/10/14 12:24.06 MICROPAS8 v8.1 File-LENNR1121 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'HOUSE' Floor Area ....................... 2967 sf Volume ........................... 32637 cf Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 23986 10978 Glazing Conduction and Solar..... 9003 10485 Infiltration ..................... 9648 5578 Internal Gain .................... n/a 2503 Ducts............................ 6792 5365 Sensible Load .................... .... 49428 ..._.. 34909 Latent Load ...................... n/a 8413 Minimum Zone Load 49428 43321 ZONE 'CASITA' Floor Area ....................... 304 sf Volume ........................... 2736 cf Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 5626 2305 Glazing Conduction and Solar..... 1109 1248 Infiltration ..................... 989 572 Internal Gain .................... n/a 248 buct5..... ...:.::. , , »: « .,»:;. « . y .. 1230 .. 794 _ ... Sensible Load .................... 8954 5166 Latent Load ...................... n/a 1245 Minimum Zone Load 8954 6411 (OF LA SAFQUlN7A F R CO F?0 * � QEPT IVSTRu �D pgrE N __� BY HVAC SIZING HVAC Page 3 Project Title.......... Lennar Homes-#1 w/Casita Date..01/10/14 12:24:06 MICROPAS8 v8.1 File-LENNR1121 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) GENERAL INFORMATION Floor Area.... 3271 sf Volume...-... ,, 35373 cf Front Orientation.......... Front Facing Sizing Location.;.;, :.. ,,..., .:;,...;;.., LA QUINTA Latitude.. ...33.8 degrees Winter Outside Design.,.,:.;»;. 26 F Winter Inside Design....:.::. 70 F Summer Outside Design.:.;::...:, 111 F Summer Inside Design...";*. 75 F Summer Range.............:::.;. 34 F Interior Shading Used...... Yes Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.24 HEATING AND COOLING LOAD SUMMARY 90 deg (E) Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 29611 13285 Glazing Conduction and Solar..... 10112 13956 Infiltration ..................... 10637 6150 Internal Gain .................... n/a 2750 Ducts.......... . «,..,> , o,. A., . *;. 8022 6563 Sensible Load .................... 58382 42703 Latent Load ...................... n/a 10292 Minimum Total Load 58382 52995 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. & LA Qljl 4-r���SApE7YpEPR CONgO V&D TiON BATE _� BY HVAC SIZING HVAC Page 4 Project Title.... ... Lennar Homes-#1 w/Casita Date..01/10/14 12:24:06 MICROPAS8 v8.1 File-LENNR1121 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'HOUSE' Floor Area ....................... 2967 sf Volume ........................... 32637 cf Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 23986 10946 Glazing Conduction and Solar..... 9003 11996 Infiltration ..................... 9648 5578 Internal Gain .................... n/a 2503 Ducts ............................ 6792 5634 Sensible Load .................... 49428 36657 Latent Load ...................... n/a 8834 Minimum Zone Load 49428 45491 ZONE 'CASITA' Floor Area ....................... 304 sf Volume ........................... 2736 cf Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 5626 2339 Glazing Conduction and Solar..... 1109 1959 Infiltration ..................... 989 572 Internal Gain .................... n/a 248 Uucts.. « « « «.......,.... .... 1230 929 Sensible Load .................... Latent Load ...................... Minimum Zone Load 8954 6047 n/a 1457 . .... ��8954� 7504 Ct'{�G'P� ' EU1Lr1:11 NjA F� EPT CONS O �( V&D oArE 5T RUC-r1 ON _-- BY HVAC SIZING HVAC Page 5 Project Title. ...... Lennar Homes-#1 w/Casita Date..01/10/14 12.24.06 ...... MICROPAS8 v8.1 File-LENNR1121 Wth-CTZ15S08 [:User -:MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) GENERAL INFORMATION Floor Area ................. 3271 sf Volume..__ ,. _.. --t.:..35373 cf Front Orientation.......... Front Facing 180 deg (S) Sizing Location............ LA QUINTA Latitude.,. 4 . -. ;;« .:.:. - :<: , 33.8 degrees Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Sumer Inside Design....... 75 F Summer Range.:;: « «:_. 34 F Interior Shading Used...... Yes Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 29611 13283 Glazing Conduction and Solar..... 10112 11730 Infiltration ............ ..:««...:. 10637 6150 Internal Gain .................... n/a 2750 Ducts ............................ 8022 6158 Sensible Load .................... 58382 40071 Latent Load ...................... n/a 9657 Minimum Total Load 58382 49728 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. R_-y Op 1 Utt_DING a sAFQUINTA FOR � � DEpT C�N�TRUCT1pN QgrE HVAC SIZING HVAC Page 6 ....:.......... Project Title..._-,..... Lennar Homes-#1 w/Casita Date..01/10/14 12:24:06 MICROPAS8 v8.1 File-LENNR1121 Nth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'HOUSE' Floor Area....;....: .:... ._. ,..:, 2967 sf Volume.. ......................... 32637 cf Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 23986 10972 Glazing Conduction and Solar..... 9003 10484 Infiltration ..................... 9648 5578 Internal Gain .................... n/a 2503 Ducts ............................ 6792 5364 Sensible Load .................... 49428 34901 Latent Load ...................... n/a 8411 Minimum Zone Load 49428 43312 ZONE 'CASITA' Floor Area ....................... 304 sf Volume ........................... 2736 cf Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 5626 2311 Glazing Conduction and Solar..... 1109 1246 Infiltration ..................... 989 572 Internal Gain .................... n/a 248 Ducts ............................ 1230 795 Sensible Load .................... 8954 5170 Latent Load ...................... n/a 1246 Minimum Zone Load 8=9=5-4�LDATE 6416 ' 0 '%N UILD/ 'OF LA �/ r y F QLJ E i-y DE pT. VED CTrON HVAC SIZING HVAC Page 7 Project Title.... Lennar Homes-#1 w/Casita Date..01/10/14 12:24:06 ....... MICROPAS8 v8.1 File-LENNR1121 Wth-CTZ15S08 User#-MP0357 .User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) GENERAL INFORMATION Floor Area ................. 3271 sf Volume ..................., 35373 cf Front Orientation ......... ;«,. Front Facing 270 deg (W) Sizing Location............ LA QUINTA Latitude ................... 33.8 degrees Winter Outside Design..:..:.::. 26 F Winter Inside Design...::.:;, 70 F Summer Outside Design....;:.;« 111 F Summer Inside Design ... ..._::. 75 F Summer Range............ 34 F Interior Shading Used.. „.., Yes Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 29611 13316 Glazing Conduction and Solar..... 10112 13954 Infiltration ..................... 10637 6150 Internal Gain .................... n/a 2750 Ducts ............................ 8022 6568 Sensible Load .................... 58382 42738 Latent Load ...................... n/a 10300 Minimum Total Load 58382 53038 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. ,s C/7-�AP E3U1�DG&v/N Fd� AFE� CEP r � C0Ns®VE© °ATF CTf �N \� BY HVAC SIZING HVAC Page 8 Project Title.... .... Lennar Homes-#1 w/Casita Date..01/10/14 12:24:06 ......... __. _ .._..._... ................ MICROPAS8 v8.1 File-LENNR1121 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 1 w/Casita(Series I) HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'HOUSE' Floor Area.—, ...... ; , .. ,<;.. ,.:« .:. , .. ;. 2967 sf 32637 cf Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 23986 10974 Glazing Conduction and Solar..... 9003 11996 Infiltration ..................... 9648 5578 Internal Gain .................... n/a 2503 Ducts.....: .,:, .:.......... ,. 6792 5638 Sensible Load .................... 49428 36688 Latent Load.......:. ._.. ...,....,. n/a 8842 Minimum Zone Load 49428 45530 ZONE 'CASITA' Floor Area ....................... 304 sf Volume ........................... 2736 cf Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 5626 2342 Glazing Conduction and Solar..... 1109 1959 Infiltration ...............<.,».:,, 989 572 Internal Gain .................... n/a 248 Ducts ............................ 1230 930 Sensible Load .................... Latent Load.,,....:-. op . .:... , .... Minimum Zone Load 8954 6049 n/a 1458 �8'95A, 7 5 07 gU/LD 01� � Qtj FDEP OR Co�7 YI�6 T. DATE RUCT 1 aN CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 1. Project Title... Lennar Homes - Plan 2 Date..01/10/14 12:20:23 Project Address.Belmont Collection . . ....... La Quinta, California *v8.1* Documentation Author... Rick Maurer Building Permit # Rick Maurer Title 24, Inc. 7544 E Saddlehill. Trail "Plan Check Date Orange, CA 92869 714-771-1507 Field Check/ Date Climate Zone........... 15 Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r04) MICROPAS8 v8.1 File-LENNR1122 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 2 (Series I) ....... . ... MICROPAS8 ENERGY USE *SUMMARY .!- Energy Use Standard Proposed Compliance Percent (kTDV/sf-yr) Design Design Margin . . ........ Improvement Space Heating. . . . 3.29 4.46 -1.17 -35.6% Space Cooling.... 77.70 73.08 4.62 5.9% Ventilation Fans.. 0 59,: 0.59 0.00 0.0% Water Heating... ... ,w. .4 i 1 57, 48 . 2 6 3.31 28.6% North Total 91�2, 4 . 6.76 7.3% Space Heating.......... .11".." I 29Y11- b,AffV 5. ' -4 -1.75 -53.2% Space Cooling.......... 74! `64 3.06 3.9% Ventilation Fans....... 0.00 0.0% Water Heating.......... 3.31 28.6% East TT. b''t 4.62 5.0% Space Heating.,_,.......,.. 3,-.29 5.46 -2.17 -66.0% Space Cooling..... . , 7_&. 4.71 6.1% Ventilation Fans...... 0.59 0.00 0.0% Water Heating..... 11.57 3.31 28.6% ....... . . . .. South Total 93.15 87.30 5.65 6.3% Space Heating... 3.29 4.80 ;-,1. 51 -45.9% Space Cooling....:..:.:.:. 77.70 73.81 3.89 5.0% Ventilation Fans.,......,,,.. 0.59 0.59 0.00 0.0% Water Heating.. . 11.57 8.26 3.31 28.6% ................ West Total 93.15 87.46 5.69 . 6.1% Building complies with Computer[Performance HERS Verification Required ford qdm' iance ,D//Vo roR C 7-YD EpT I4ttmo ll Wetat CHEERS.com by James Jenike (Lcnnar Homes) - 1110/2014 4:22:41 PM SlGcitWliialCi 6&by Rick Maurer and Authenticated at CHEERS.corn - 0 1 /10/2014 01:39 PM Regis** 00/10/2014 1:39:22 PM * Registration Number: 413-NO012977B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2 .........._._____........_........._...... Project Title.. Lennar Homes Plan 2 Date..01/10/14 12:20.23 MICROPAS8 v8.1 File-LENNR1122 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 2 (Series I) GENERAL INFORMATION .................... .....:... . HERS Verification... ..... Required Conditioned Floor Area..... 3153 sf Building Type .............. Single Family Detached Construction Type ......... New Natural Gas at Site ....... Yes Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 1 Conditioned Volume......... 34683 cf Slab -On -Grade Area......... 3153 sf Glazing Percentage......... 20.3 % of floor area Average Glazing U-factor... 0.35 Btu/hr-sf-F Average Glazing SHGC. 0.25 Average Ceiling Height ,11 ft U1T>E?ING ��$ INFORMATION Floor # of #..of .fond- Thermo- Vent Vent Verified Area Volume Dwell Peop'- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap Residence 3153 34683 $«tt0` =f} Y �Setb, ek: 2.0 Standard No l ?Tip A$li tCt ZV4 Frame R- R- Roof Roof Re- Emiss- Frame Spac- Value Value Vent Mass Rise fleet- ivity Depth ing Above Below Area Vent Roof Type (lb/sqft) ance (in.) (in.) Deck Deck Ratio High Tile Heavy 3:12 0.16 0.89 3.5 24 oc 0.00 0.00 1/300 0.30 D11V0 & FOR� E QEP q aq co rE TipN �\ ay Electronically Signed at CHEERS.com by James Jenike (Lennar Homes)-1/10/2014 4:22:41 PM Electronically Filed by Rick Maurer and Authenticated at CHEERS.com - 01/102014 01:39 PM Registered with CHEERS on 1/10/2014 1:39:22 PM' Registration Number: 413-N001297713-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3 _. n n1 /-t n /1 n 1 �.7n.77 Project T1tle. Lennar domes r.t.uu G ua�c..vt/1V/1s lc.Z_V.a� MICROPAS8 v8.1 File-LENNR1122 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 2 (Series I) OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains JA4 Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments .. 1 Wall Wood 365 0.069 21 0 0 90 Yes 4.3.1 A6 Front 2x6 Wall 2 KneeWall Wood 106 0.069 21 0 0 90 Yes 4.3.1 A6 Attic KneeWall 3 Wall Wood 50 0.095 15 0 0 90 No 4.3.1 A4 Gar. Wall 4 Wall Wood 199 0.069 21 0 0 90 No 4.3.1 A6 Gar. 2x6 Wall 5 Wall Wood 561 0.069 21 0 90 90 Yes 4.3.1 A6 Left 2x6 Wall 6 KneeWall Wood 14 0.069 21 0 90 90 Yes 4.3.1 A6 Attic KneeWall 7 Wall Wood 500 0.069 21 0 180 90 Yes 4.3.1 A6 Back 2x6 Wall 8 Wall Wood 100 0.069 21 0 180 90 No 4.3.1 A6 Gar. 2x6 Wall 9 Wall Wood 10 0.095 15 0 270 90 Yes 4.3.1 A4 Right Wall 10 Wall Wood 420 0.069 21 0 270 90 Yes 4.3.1 A6 Right 2x6 Wall 11 KneeWall Wood 70 0.069 21 0 270 90 Yes 4.3.1 A6 Attic KneeWall 12 AtticRad Wood 3153 0.025 38 -:0 n/a 0 Yes 4.2.1 A21 Vented Attic 13 Door Wood 28 0.500 0 0 0 90 Yes 4.5.1 A4 Front Door 14 Door Wood 21 0.500 0 0 90 No 4.5.1 A4 Garage Door 5 Appendix Length F2 Inctl Solar JA4 Location/ Surface (ft) Factor R-va1 Gains Reference Comments 15 S1abEdge 272 fl 739 ? A_1tandd. S"etb. Ldg .: ( Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments 1 Wind Front `N)r: 15.0 0.350 0.250 0 90 Standard FGLASSI 2 Wind Front (N;) 36.0 0.350 0.250 0 90 Standard FGLASS2 3 Wind Front (:N.j; 36.0 0.350 0.250 0 90 Standard FGLASS3 4 Wind Left (:Ej;; 36.0 0.350 0.250 90 90 Standard LGLASSI 5 Wind Left (E} 30.0 0.350 0.250 90 90 Standard LGLASS2 6 Wind Left (Ej 7.5 0.350 0.250 90 90 Standard LGLASS3 7 Wind Left (E) 22.0 0.350 0.250 90 90 Standard LGLASS4 8 Wind Left (Ey 15.0 0.350 0.250 90 90 Standard LGLASSS 9 Door Back (.5).', 48.0 0.350 0.250 180 90 Standard BGLASSI 10 Wind Back (Sj' 48.0 0.350 0.250 180 90 Stp �-h'dard BGLASS2 11 Wind Back (S)27.0 0.350 0.250 180 90 Starrdard`BGLASS3 12 Door Back (Sy 144.0 0.350 0.250 180 90 Staard'B jTrAS� Fp sAFRT y ' Vp R GOBS °ATF Cr10N Electronically Signed akC IEFRS to ti by 3art-0 7enike (Lennar Homes)-1/10/2014 4:22:41 PM Electronically Filed by Rtck.'Maur�arid AAfttic ated at CHEERS.com - 01/10/2014 01:39 PM Registered with CHEERS on' PM • Aegistration Number. 413-N0012977B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4 ................ .................. n Al /1 !1 /1 A '1 7_ ')A _ 7 7 Project '1'1Lle �: . Lennar Homes Plan G La Le 01 10/is 12.e-0:2 MICROPAS8 v8.1 File-LENNR1122 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 2 (Series I) FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments 13 Wind Back (S) 15.0 0.350 0.250 180 90 Standard BGLASS5 14 Door Back (S) 80.0 0.350 0.250 180 90 Standard BGLASS6 15 Wind Right (W-) 8.0 0.350 0.250 270 90 Standard RGLASSI 16 Wind Right (W:): 36.0 0.350 0.250 270 90 Standard RGLASS2 17 Door Right (,W)y 21.4 0.350 0.250 270 90 Standard RGLASS3 18 Wind Right (W) 15.0 0.350 0.250 270 90 Standard RGLASS4 OVERHANGS -Window- Area Left Right Surface (sf) Width Height Depth Height Extension Extension 1 Window 15.0 n/a 5.0 7�,« 0 , ' 0.3 n/a n/a 2 Window 36.0 n/a 6 0.: �» -0.3 n/a n/a 3 Window 36.0 n/a 6.0 0.3 n/a n/a 4 Window 36.0 n/a 6.0` T 3.0 n/a n/a 5 Window 30.0 n/a 6.0 ]. 4.0 n/a n/a 6 Window 7.5 n/a 1.5;»=5:: 2.0 n/a n/a 7 Window 22.0 n/a 5.5 = 2.0 n/a n/a 8 Window 15.0 n/a 6.0 6..6 0.0 n/a n/a 9 Door 48.0 n a 8 .,0 l Q 5.- 1 .s5. n/a n/a 10 Window 48.0 n/a3 6 0 15 -: n/a n/a 11 Window 27.0 n`a 15j_..'`"" 1 .0 n/a n/a 12 Door 144.0 n./a 8.0 11.. 3.0 n/a n/a 13 Window 15.0 nMfi %�--ra1i.5- ` 1. 0 - n/a n/a 14 Door 80.0 n/a 8.0 11. 3.0 n/a n/a 15 Window 8.0 n/a 4.0 1.5 2.0 n/a n/a 16 Window 36.0 n/a 6.0 1.5 2.0 n/a n/a 17 Door 21.4 n/a 8.0 1.5 2.0 n/a n/a 18 Window 15.0 n/a 6.0 6.0 0.0 n/a n/a SLAB SURFACES Area Slab Type (sf) Standard Slab 3153 C/� F $"`LD/,,V0 & Qtj/ R CCAlSQ v T. �TF CPCM SY SibCE►rtn"ty 9igncd at tlEiE iLS c12a1 by lets JeaiR� (Lennar Homes)-1/10/2014 :2-ALELA 4 �IacETORteatt f b Ru c MSutoe and Audm� oatext;at CHEfiRS.com - Ol/] 0/1014 01:39 P Register wsth �E att Vt�139 22 P[kC'' !Wstration Number: 413-N0012977B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5 Project Title.......... Lennar Homes -. Plan 2 Date. 01/10 14 12 20 23 MICROPAS8 v8.1 File-LENNR1122 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 2 (Series I) HVAC SYSTEMS Verified Verified Verified Verified Verified Maximum System Minimum Refrig Charge Adequate Fan Watt Cooling Type . Efficiency EER or CID Airflow Draw Capacity .. Furnace 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 13.00 SEER 11.5 No No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr) Furnace n/a n/a n/a ACSplit ri p 48609 n/a E��cienrtat on ofaxil�l Front Facing 90 deg (E) Ss1ng location , LA QUINTA inter Outside Des g�i, � , 26 F er, L'ns�d Uesligrts ... ; , , 70 F ill F Summer .Tnai�t� Deb g1� ...::� x .., 75 F Sututter itange.a, ev Vttj Verified Verified System [)uct DUC -- >x�ir Surface Buried Type Location R-vele 1,ea)t;ge Area Ducts ......... Furnace Attic R-6 Yes No No ACSplit Attic R-6 Yes No No C1 1' rr- S"ETy pEP FOR Co N � � DATE UST iON _� gY Electronically Signed at CHEERS;eom � Jonet Jenike (Lennar Homes)-1/10/2014 4:22.41 PM Electronically Filed by $e�k'Maurerand Auth ticated at CHEERS.com - 01/10/2014 01:39 PM Registered with CHEERS on 1i10/ t114 5: PM *:Registration Number. 413-N0012977B-M000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6 .._... ... . Project Title... Lennar Homes Plan 2 Date..01/10/14 12:20:23 MICROPAS8 v8.1 File-LENNR1122 Wth-CTZ15S08 Useri-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 2 (Series I) FAN SYSTEMS Flow Power System Type (cfm) (W/cfm) Standard 61.53 .25 WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value .. 1 SmallInstanta Gas Recirc/DemandManual 1 .82 n/a R-n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check*wand'field inspection. *** This is a multiple orientation builda3r" T'hi s gritut -is. %:or bhe fi that facing North.��•. This building incorporates a Radiant4Barrier This building incorporates a Cool Roof. This building incorporatea 1To� sandard Wt"r Heating System. s t U,,HERS RFQUI'RE'DV'VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified High Energy Efficiency Ratio (EER). This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. LA QU/ �SAFE7Y CEP A OR CCNS®V,�� L)ATF rlo v By I Icatpmii3&11 S!.��ncted aE GH S anti by lames 7enike (Lennar Homes)-1/1012014 4:22:41 PM Electrbrtiyal y FSttd byr Im 'U. u E aitd Authenticated at CHEERS.com - 01/10/2014 01:39 PM Regist ro O(!HEk?RS on 11.1Qt2Q141,39 2 PM * Registration Number: 413-N0012977B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 7 _.. Proiect Title..... a: Lennar Homes Plan 2 Date..01/10/14 12:20:23 MICROPAS8 v8.1 File-LENNR1122 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 2 (Series I) REMARKS 1) This house will have Cool Roof rated concrete tiles with .16 minimum aged reflectance and .89 minimum emissivity. 2) All hot water lines will be insulated per Sec. 150(J) with a minimum of 1 inch insulation. This is an addition to the insulation required by the mandatory requirements. 3) The water heater for this house will have a hot water demand type recirculating system with manual control. 4) This house will have a tankless water heater with an energy factor of .82 or greater and sized per the owner's specifications. 5) All windows and glass doors will have non-metal frames with a weighted average NFRC U-factor of .35 or less and a weighted average SHGC of .25 or less with high performance Low-E (Max) glass. 0 FO E' Q�P CO/V V � 0ATF rRUCTI01V Electronically Signed at CHEERS.com by Jams Tc i#e (Lennar Homes)-1/10/2014 4:22:41 PM Electronically Filed by Rick Maurer and Audi, nitt w4 at CHEERS.eom - 01 /10/2014 01:39 PM Registered with CHEERS on 1/10/2014 1:39:22 PM *'kegistiation Number: 413-N0012977B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 8 ..ro3ect '1'1Lle. a:: . .Lennar Homes Plan G Ua Le..U1/1V/19 1L. LV:L MICROPAS8 v8.1 File-LENNR1122 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 2 (Series I), COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER Name.... Name.... Company. 'Lennar`Homes Company. Address. 980 Montecito Drive,#302 Address. Corona, CA 92879 Phone... (951) 817-35 65 Phone;..;.:. ......:... License. _ .... Signed.. Name... Title. Agency.. Phone... Signed .: .:: Signed.. DOCUMENTATION AUTHOR Rick Maurer Rick Maurer Title 24, Inc. 7544 E Saddlehill Trail Orange, CA 92869 714-771-1507 a/, y {date); cnry D;;VG a Lei �Cl/N rA 3 S�FE� 1, DEp-r OF? ColVs� UgTE r/QIV Electronically Signed at CHEERS.conr by James Jenike (L ennar Homes) -1 /10t2014 4:22:41 PM Electronically Filed by Rick Maurer and Authenticated at CHEERS.com - 01/10/2014 01:39 PM Registered with CHEERS on 1/10/20141:39:22 PM * Registration Number: 413-N0012977B-000000000-0000 HVAC SIZING HVAC Page 1 Project Title.,..r....:;...... Lennar Homes - Plan 2 Date..01/10/14 12:20:23 Project Address........ Belmont Collection ****** La Quinta, California *v8.l* ****** Documentation Author... Rick Maurer Building Permit # Rick Maurer Title 24, Inc. 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Check/ Date Climate Zone. .. 15 _..._. Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r04) MICROPAS8 v8.1 File-LENNR1122 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 2 (Series I) GENERAL INFORMATION Floor Area ................. 3153 sf Volume ..................... 34683 cf Front Orientation.......... Front Facing 0 deg (N) Sizing Location............ LA QUINTA Latitude ................... 33.8 degrees Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F SummerRange ............... 34 F Interior Shading Used.,.:.:;:.: Yes Exterior Shading Used;: ..., Yes Overhang Shading Used....,..,..,;Yes Latent Load Fraction....... 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 24682 11367 Glazing Conduction and Solar..... 9854 11929 Infiltration ..................... 10253 5928 Internal Gain .................... n/a 2520 Ducts ............................ 7135 5764 Sensible Load .................... 51925 37509 Latent Load ...................... �n as 9040 Minimum Total Load 5-1:_9,,�5 "f_ 1-4--65,4--8 N(3 & �AFF7f�� Note: The loads shown are only one of the criteria/Aa-ffect ng thetas-eilection of HVAC equipment. Other relevant des M�gn factQrs�fsu�ch Y9s-air flow requirements, outside air, outdoor design temperatures,(JccYoil sizing, availability of equipment, oversizing safetyTmargin, etc., musty also be considered. It is the HVAC designer's responsil-it�Btyo consider all factors when selecting the HVAC equipment. HVAC SIZING HVAC Page 2 Project Title.......... Lennar Homes Plan 2 Date..01/10/14 12:20:23 MICROPAS8 v8.1 File-LENNR1122 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 2 (Series I) GENERAL INFORMATION Floor Area ................. Volume ..................... Front Orientation.......... Sizing Location............ Latitude ................... Winter Outside Design...,:.,t Winter Inside Design... Summer Outside Design..:.:.;. Summer Inside Design...:::.:«.. Summer Range.......... ........ Interior Shading Used..,. Exterior Shading Used..:,:,-:.:.; Overhang Shading Used.. Latent Load Fraction.....:..,. 3153 sf 34683 cf Front Facing LA QUINTA 33.8 degrees 26 F 70 F Ill F 75 F 34 F Yes Yes Yes 0.24 90 deg (E) HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 24682 11433 Glazing Conduction and Solar..... 9854 13268 Infiltration ..................... 10253 5928 Internal Gain .................... n/a 2520 DCts..<....:::.:..... .,.,... »:>..:-.: 7135 6020 Sensible Load, ...:.yt„R11.;.:.:: 51925 39169 Latent Load. ......... ..,::.- n/a 9440 Minimum Total Load 51925 48609 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. G/py OF s'q QIJe 7-A FoR co Roy _pT oqT NSTR(1 �D N HVAC SIZING HVAC Page 3 Project Title.......... Lennar Homes - Plan 2 Date..01/10/14 12:20:23 ....... . MICROPAS8 v8.1 File-LENNR1122 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 2 (Series I) GENERAL INFORMATION Floor Area ................. 3153 sf Volume ..................... 34683 cf Front Orientation.......... Front Facing Sizing Location............ LA QUINTA Latitude,....._,.. ii ., 4 33.8 degrees Winter Outside Design...-.: 26 F Winter Inside Design..,..;. 70 F Summer Outside Design.:...;.:.;,. 111 F Summer Inside Design....,.. 75 F Summer Range......... A..i 34 F Interior Shading Used...,..,0, Yes Exterior Shading Used...-...,,. Yes Overhang Shading Used..,,,:.,... Yes Latent Load Fraction....:.;..:::. 0.24 HEATING AND COOLING LOAD SUMMARY 180 deg (S) Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... Glazing Conduction and Solar..... Infiltration ..................... InternalGain .................... Ducts............................ Sensible Load .................... Latent Load ...................... 24682 11398 9854 11928 10253 5928 n/a 2520 7135 5770 51925 ... 37543 n/a 9048 Minimum Total Load 51925 46591 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Pro D a41-� CO/VSgUCr� �ey HVAC SIZING HVAC Page 4 Project Title .... Lennar Homes - Plan 2 Date..01/10/14 12:20.23 MICROPAS8 v8.1 File-LENNR1122 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 2 (Series I) GENERAL INFORMATION Floor Area ................. 3153 sf Volume ..................... 34683 cf Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ LA QUINTA Latitude ................... 33.8 degrees Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F Interior Shading Used...... Yes Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 24682 11414 Glazing Conduction and Solar..... 9854 13268 Infiltration ..................... 10253 5928 Internal Gain .................... n/a 2520 Ducts ............................ 7135 6016 Sensible Load .................... 51925 39145 Latent Load ...................... n/a 9434 Minimum Total Load 51925 48579 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. EU,Q)/&'G & QFo� �� T oRO � NST� �6 °ATE /QN `� By CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1 Project Title...... .. Lennar Homes - Plan 3 Date..Ql/10/14 12:20:30 Project Address......... Belmont Collection ****** --- La Quinta, California *v8.1* Documentation Author..-.:.. Rick Maurer ****** Building Permit Rick Maurer Title 24, Inc. 7544 E Saddlehill Trail Plan Check Date Orange, CA 92869 :......::::: 71.4-771-1507 Field Check Date Climate Zone........... 15 Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r04) MICROPAS8 v8.1 File-LENNR1123 Wth-CTZ15S08 =U�ser�#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 3 (Series I) Energy Use (kTDV/sf-yr) Space Heating.........,.;:. Space Cooling.... _ Ventilation Fans...;,..:. Water Heating......<..::. North Total Space Heating.. Space Cooling... Ventilation Fans.:...:.. Water Heating.....,:<:. MICROPAS8 ENERGY USE SUMMARY Standard Proposed Compliance Percent Design Design Margin Improvement ...... 3.55 .......... 5.13 -1.58 -44.5% 76.51 74.57 1.94 2.5% 0.61_ -, 0.61 0.00 0.0% 9.67 6.38 3.29 34.0% 9El.�34 86.69 3.65 4.0% 3 55 5.68 -2.13 -60.0°% 76.51 75.08 1.43 1.9% 0.61 0.61 0.00 0.0% 9.67 6.38 3.29 34.0% East Total �Q.34 8,775r 2.59 2.9 % Space Heating... 3..55 6.11 -2.56 -72.1% Space Cooling... ''73.48 `. 3.03 4.0% Ventilation Fans....... 0.61 0.61 0.00 0.0% Water Heating........., 9.67 6.38 3.29 34.0% South Total 90.34 86.58 3.76 4.2% Space Heating...:.;.::;::;. 3.55 5.33 -1.78 -50.1% Space Cooling...:::....:.,::: 76.51 73.67 2.84 3.7% Ventilation Fans:R..:...-.,. 0.61 0.61 0.00 0.0% Water Heating.....,...:;:.:..: 9.67 6.38 3;029 34.0% West Total 90.34 85.99 4.35 4.8% *** Building complies with Computer Performance *** *** HERS Verification Required ifor Compliance *** BULL p O p LA Qtj F,q�,p & StiFF�Y p� rA OR Co V V�6 T. DATE RUCT/O" �� ay Electronically Signed at CHEERS.com by James Jenike (Lennar Homes)-1/10/2014 4:23:30 PM 1 Electronically Filed by Rick Maurer and Authenticated at CHEERS.00m - 01/10/2014 01:40 PM Registered with CHEERS on 1/10/2014 1:39:57 PM • Registration Number: 413-N001297813-W0000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2 Project Title......;.... Lennar Homes Plan 3 Date..01/10/14 12:20:30 MICROPAS8 v8.1 File-LENNR1123 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 3 (Series I} GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 3771 sf Building Type .............. Single Family Detached Construction Type New Natural Gas at Site ....... Yes Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 1 Conditioned Volume......... 43366 cf Slab -On -Grade Area......... 3771 sf Glazing Percentage......... 20.8 % of floor area Average Glazing U-factor... 0.35 Btu/hr-sf-F Average Glazing SHGC.., 0.25 Average Ceiling Heig2it 11.5 ft TITJTLDING.,f& INFORMATION Floor # of #: of ­'ICond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le' ioned Type (ft) (sf) Housewrap .. ......... Residence 3771 43366, 11DO 3.0 ;; , t% .,pk, 2.0 Standard No ' ATTIC . 1t .,OF R- R- Roof Roof ite- Em3s-,'1"aie SSac= Value Value Vent Mass Rise Above Below Area Vent Roof Type (lb/sgft) air {iri } (ir. } Deck Deck Ratio High Tile Heavy 3:12 0.16 0.89 3.5 24 oc 0.00 0.00 1/300 0.30 C/,ry atJ/Lt)/A1� & c�C�, F�R� ��1 Y p�Cp o coNSTR ��� ATE /QN 8y Electronically Signed at CHEERS votliby fame4)mtlzc':(C ennar Homes)-1/10/2014 4:23:30 PM Electronically Filed by Rick Mauro "Id. AttWcti W9W'd at CHEERS.com - 01 /10/2014 01:40 PM Registered with CHEERS on 1/10/2014 (39:5 AM * ,*"stration Number: 413-N0012978B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3 Project Title.. .... Lennar Homes Plan 3 Date..01/10/14 12:20:30 MICROPAS8 v8.1 File-LENNR1123 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 3 (Series I) Frame Area Surface Type (sf) 1 Wall Wood 327 2 KneeWall Wood 64 3 Wall Wood 310 4 Wall Wood 889 5 Wall Wood 99 6 Wall Wood 470 7 Wall Wood 764 8 Wall Wood 149 9 AtticRad Wood 3771 10 Door Wood 28 11 Door Wood 21 12 Door Wood 21 OPAQUE SURFACES U- Sheath- fact- Cavity ing Act or R-val R-val Azm Tilt 0.069 21 0 0 90 0.069 21 0 0 90 0.069 21 0 0 90 0.069 21 0 90 90 0.069 21 0 90 90 0.069 21 0 180 90 0.069 21 0 270 90 0.095 15 0 270 90 0.025 38 0 n/a 0 0.500 0 0 0 90 0.500 0 0 0 90 0.500 0 0 0 90 Length F2 I Surface (ft) Factor it 13 S1abEdge 346 0.730 R-0/0 Solar Appendix Gains JA4 Location/ Reference Comments Yes 4.3.1 A6 Front 2x6 Wall Yes 4.3.1 A6 Attic KneeWall No 4.3.1 A6 Gar. 2x6 Wall Yes 4.3.1 A6 Left 2x6 Wall No 4.3.1 A6 Gar. 2x6 Wall Yes 4.3.1 A6 Back 2x6 Wall Yes 4.3.1 A6 Right 2x6 Wall No 4.3.1 A4 Gar. Wall Yes 4.2.1 A21 Vented Attic Yes 4.5.1 A4 Front Door No 4.5.1 A4 Garage Door No 4.5.1 A4 Garage Door LOSSES Appendix "'Solar JA4 Location/ 'Gains Reference Comments No 4.4.7 Al Standard Slab Edge F NESTRATION...SURFACES, #r .. 3 4­ Exterior Area U- Act Shade Orientation (sf) fact"'vSAGCrAzm Tilt 'Tyype Location/Comments ....._ 1 Wind Front (N) 8.0 0.350 0.250 0 90 Standard FGLASSI 2 Wind Front (Ny, 17.5 0.350 0.250 0 90 Standard FGLASS2 3 Wind Front (a) 18.0 0.350 0.250 0 90 Standard FGLASS3 4 Wind Front (Nj. 18.0 0.350 0.250 0 90 Standard FGLASS4 5 Door Front (N}; 24.0 0.350 0.250 0 90 Standard FGLASS5 6 Door Left (ky,24.0 0.350 0.250 90 90 Standard LGLASSI 7 Wind Left MY 4.5 0.350 0.250 90 90 Standard LGLASS2 8 Wind Left (E).. 36.0 0.350 0.250 90 90 Standard LGLASS3 9 Wind Left (E}� 36.0 0.350 0.250 90 90 Standard LGLASS4 10 Wind Back (Sy 18.0 0.350 0.250 180 90 Standard BGLASSI 11 Wind Back (Sj 36.0 0.350 0.250 180 90 Standard BGLASS2 12 Wind Back (S� 36.0 0.350 0.250 180 90---Standard BGLASS3 13 Wind Back ($y 36.0 0.350 0.250 180 90 Standard:BGLASS4 14 Door Back (S 192.0 0.350 0.250 180 9k0 S.tan�dardiBGLASSS F� � � E? DEp-r CON -S jCr OArt: �QN sY Electronically Signed ]<t C:ltis'Yi1Md'gtri by ram dts cc;(l.el r Homes)-1/10/2014 4:23:30 PM Electronically Filed byie1t Mattrcradd Atttt001:1d Ck11vERS.com - Ol/10/2014 01:40 PM Registered with CHEERS on 16EQ7�2014 13* 57ir ? er i�e�lst tm-i_14"I r: 4t3-N00129786-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 4- Al /1n /1n 1').on.'4n 'ro3ecz riLie.:..:..:.. 1JU1111CAt nullltlU r1C►11 J uac..vi, iv, iz ac .cv. MICROPAS8 v8 1 File-LENNR1123 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 2.4, Inc Run -Plan 3 (Series I) FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Am Tilt Type Location/Comments 15 Wind - Back -(S} 13.5 0.350 0.250 ---. 180 90 Standard BGLASS6 16 Wind Back (S} 54.0 0.350 0.250 180 90 Standard BGLASS7 17 Wind Back (S) 9.0 0.350 0.250 180 90 Standard BGLASS8 18 Wind Back (Sj 36.0 0.350 0.250 180 90 Standard BGLASS9 19 Door Right ',(W) 96.0 0.350 0.250 270 90 Standard RGLASSI 20 Wind Right (W): 18.0 0.350 0.250 270 90 Standard RGLASS2 21 Wind Right (W): 30.0 0.350 0.250 270 90 Standard RGLASS3 22 Wind Right (W) 7.5 0.350 0.250 270 90 Standard RGLASS4 23 Wind Right IW'} 16.0 0.350 0.250 270 90 Standard RGLASS5 OVERHANGS -Window-- ...... ......rhang _ Surface Area (sf) Width Hei ht g ��t% Height Left Extension Right Extension .._._. 1 Window 8.0 n/a 4 0 5 1.0 n/a n/a 2 Window 17.5 n/a 7.0 1.0 n/a n/a 3 Window 18.0 n/a 6.0 3 1.0 n/a n/a 4 Window 18.0 n/a 6.0 1*0 1.0 n/a n/a 5 Door 24.0 n/a 8.0 3,i3 1.0 n/a n/a 6 Door 24.0 n/" $,0 6 0 3 0 o n/a n/a 7 Window 4.5 r/a k5 6 1_g0= n/a n/a 8 Window 36.0 6-0 1:.5 4.0' n/a n/a 9 Window 36.0 n/a U 1 4.0 n/a n/a 10 Window 18.0 �� €s2 '0' #. ° n/a n/a 11 Window 36.0 n/a 6.0 1.5 4.0 n/a n/a 12 Window 36.0 n/a 6.0 1.5 4.0 n/a n/a 13 Window 36.0 n/a 1.5 24. 1.0 n/a n/a 14 Door 192.0 n/a 8.0 24. 3.0 n/a n/a 15 Window 13.5 n/a 1.5 1.5 2.0 n/a n/a 16 Window 54.0 n/a 6.0 1.5 4.0 n/a n/a 17 Window 9.0 n/a 1.5 1.5 2.0 n/a n/a 18 Window 36.0 n/a 6.0 1.5 4.0 n/a n/a 19 Door 96.0 n/a 8.0 10. 3.0 n/a n/a 20 Window 18.0 n/a 1.5 10. 1.0 n/a n/a 21 Window 30.0 n/a 6.0 1.5 2.0 n/a n/a 22 Window 7.5 n/a 1.5 1.5 4.0 n/a n/a 23 Window 16.0 n/a 4.0 1.5 4.0 n/a n/a 1110 AFC, Tq FOR C fl �� �� o�Pi DATE STRUCT/® 6y Electronically Signed at CHEERS.com,by 1aMoa1tttiktt (Lennar Homes)-1/10/2014 4:23:30 PM Electronically Filed by Rick Maurer anti Authra�t3 od at CHEERS.com - O111012014 01:40 PM Registered with CHEERS on 1/10/20141:39:57 04 Rig Os ion Number: 413-N0012978B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5 ?roject Title.:. Lennar Homes Plan 3 Date..01/10/14 16:20:3l _. ..:: ........ MICROPAS8 v8.1 File-LENNR1123 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 3 (Series I) SLAB SURFACES Area Slab Type (sf) .......... Standard Slab 3771 HVAC SYSTEMS Verified Verified Verified Verified Verified Maximum System Minimum Refrig Charge Adequate Fan Watt Cooling Type Efficiency EER or CID Airflow Draw Capacity Furnace 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 13.00 SEER 11.5 No No No No HVAC SIZING Total Heating System Load Type (Btu/hr) Furnace 64597 ACSplit n/a Verified Design Maximum Cooling Cooling Capacity Capacity (Btu/hr) (Btu/hr) n/a _ n/a 58370 n/a Orientat= on of Maximum: t_Frodt� Facing 90 deg (E) Sizing Lbdat h....:.. :.. LA QUINTA Winter Outside Design......126 F Winter Tnsidek°be°sign$::: Summer Outside Design...... 111 F Summer Inside Design....... 75 F SummerRange ............... 34 F DUCT SYSTEMS Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R-value Leakage Area Ducts _. Furnace Attic R-6 Yes No No ACSplit Attic R-6 Yes` No No C l �" e�,I�Dj a l NrA FpR CO DATE TRUCTIoN 1~laotrcmaall3� S�d Ott �Cottc by 7am� 7cnikc (LCnt�Y Tomes) -1 J10i1014 4:23:30 PM �la�mnics7l� l±t by R,ss1c';341aun;e anri Autl�cilx�&tet� #t CiiIIS.com - 01110/2014 01:40 PM Regi.;40d t1it6;EHF'.SR$-on IflQ12Qt4 1 39 5 Flvl s R g1SttAYiOri I�Iutc}ber: 413-N0012978B 000000000 0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6 Al /1 n 11 A 1 7. 7non Project T1L1e.,, . e.:. ,enriaf h0rueS rta" J Vi/ iv/ MICROPAS8 v8.1 File-LENNR1123 Wth-CTZ15SO8 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 3 (Series I) FAN SYSTEMS Flow Power System Type (cfm) (W/cfm) Standard 75.21 .25 WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value 1 SmallInstanta Gas Recirc/DemandManual 2 .82 n/a R-n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer -and: CEC specifications, and *** *** verified during plan cheCi�'and field inspection. *** Ax This is a multiple orientation bulrmg This printout is for the front facing North. This building �ngts;xorctes .a: This building Yneocsors :a; Cob1 RtSo£., This building 3.riddx�porat s t� s da cl l x i1W#t�A System. `HERS IRE "`VERTFICATI:ON *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified High Energy Efficiency Ratio (EER). This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not instahledlthen HERS verification is not necessary. g I �JF UILDI G S 9-'t� Fo k R Ca�vs�/ATE Electronically Signed At6496tS,tom by dames Jenike (Lennar Homes)-1/10/2014 4:23:30 PM Electronically Filed by Rick MauKct:eatd Authenticated at CHEERS.com - 01/10/2014 01:40 PM Registered with CHEERS on 1/iQ/2014 1,39 S.7 PM' Registration Number: 413-N0012979B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 7 'roject Title...; . Lennar Homes Plan 3 Date..01/10/14 12:20:31 MICROPAS8 v8.1 File-LENNR1123 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 3 (Series I) REMARKS 1) This house will have Cool Roof rated concrete tiles with .16 minimum aged reflectance and .89 minimum emissivity. 2) All hot water lines will be insulated per Sec. 150(J) with a minimum of 1 inch insulation. This is an addition to the insulation required by the mandatory requirements. 3) The water heaters for this house will have a hot water demand type recirculating system with manual control. 4) This house will have two tankless water heaters with an energy factor of .82 or greater and sized per the owner's specifications. 5) All windows and glass doors will have non-metal frames with a weighted average NFRC U-factor of .35 or less and a weighted average SHGC of .25 or less with high performance Low-E (Max) glass. 8U1L p�N(3 Qtjy FORC�i��, ETy CEP r o �NSrR C�o ATF /Ofv Electronically Sigaed at CHEERS.com by James Jenike (Lenmar Homes) - 1/10/2014 4:23:30 PM Electronically Filed by Rick Maurer and Authenticated at CHEERS.com - 01/10/2014 01:40 PM Registered with CHEERS on 1/10/2014 1:39:57 PM ' Registration Number: 413-N0012978B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 8 Project Title.......... Lennar Homes Plan 3 Date..01/10/14 12:20:30 .... MICROPAS8 v8.1 File-LENNR1123 Wth-CTZ15SO8 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 3 (Series I) COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications neededto comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER Name.. . . ........... .......:... Company. Lennar Homes` Address. 980 Montecito Drive,#302 Corona, CA 92879 Phone.... (951) 817-3565 License. Signed.:. (dat t e), DOCUMENTATION AUTHOR Name....: Rick Maurer Company: Rick Maurer Title 24, Inc. Address.. 7544 E Saddlehill Trail Orange, CA 92869 Phone.:;:...714-771-1507 Signed.. (date ::. FOR E1�• QEF q CANS;RUC D OATS /QA1 `� By Electronically Signed at CHEERS.com by James Jenike (Lennar Homes) - 1/10/2014 4:23:30 PM Electronically Piled by Rick Maurer and Authenticated at CHEERS.com - 01 /10/2014 01:40 PM Registered with CHEERS on 1/10/2014 1:39:57 PM * Registration Number. 413-N0012978B-000000000-0000 HVAC SIZING HVAC Page 1 Project Title Lennar Homes - Plan 3 Date..01/10/14 12:20:30 Project Address........ Belmont Collection La Quinta, California *v8.1* Documentation Author... Rick Maurer ****** Building Permit Rick Maurer Title 24, Inc. 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Check/ Date Climate Zone........... 15 Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r04) MICROPAS8 v8.1 File-LENNR1123 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 3 (Series I) GENERAL INFORMATION Floor Area............:..;.,:. 3771 sf Volume ................::;..; 43366 cf Front Orientation......,.. ,..;...;, Front Facing 0 deg (N) Sizing Location....... ..;.,«, LA QUINTA Latitude,.:..:..:. ..,.••. 33.8 degrees Winter Outside Design....,:..:;, .;: 26 F Winter Inside Design.70 F Summer Outside Design..; .::..,.= 111 F Summer Inside Design...:.:::.,:,:. 75 F Summer Range..........;.;:. 34 F Interior Shading Used...... Yes Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 31385 14502 Glazing Conduction and Solar..... 12074 14875 Infiltration ..................... 12263 7090 Internal Gain .................... n/a 2750 Ducts ............................ 8876 7121 .................. Sensible Load,. {.' R .:, , . ,:.;,.;. `:. 6;4597 46338 Latent Load ..... ... ....... .. � Ial ri/��1.1168 Minimum Total Loa/� 6445911 /1" 61'� l .FC _ Flo Note: The loads shown are only one of the crit&ria3faffectkngthe, s lection of HVAC equipment. Other relevant �d sign facto'�� h,__11 ha as air flow requirements, outside air, outdoor des iC]i temperatures, _oil sizing, availability of equipment, oversizing safe margi:gV etc., must also be considered. It is the HVAC designer's respond s'b 'ty —toco sider .all factors when selecting the HVAC equipment. HVAC SIZING HVAC Page 2 Project Title.......... Lennar Homes Plan 3 Date..01/10/14 12:20:30 ... MICROPAS8 v8.1 File-LENNR1123 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 3 (Series I) GENERAL INFORMATION Floor Area ................. 3771 sf Volume. .;, 43366 cf Front Orientation.. ...,.:.». Front Facing Sizing Location.......««....«« LA gUINTA Latitude .... .. .... .,:. 33.8 degrees Winter Outside Design.....:. 26 F Winter Inside Design. .,.:.:;« 70 F Summer Outside Design.!,..',,.. 111 F Summer Inside Design... .«;:,> 75 F Summer Range......... :..:: 34 F Interior Shading Used...... Yes Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.24 90 deg (E) HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... Glazing Conduction and Solar..... Infiltration ..................... Internal Gain..: ................. Ducts............................ Sensible Load........-..;_» ....... » . , Latent Load ...................... Minimum Total Load 31385 14086 12074 15880 12263 7090 n/a 2750 8876 7228 64597 47035 n/a 11335 64597 58370 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING HVAC Page 3 Project Title.......... Lennar Homes Plan 3 Date..01/10/14 12:20:30 MICROPAS8 v8.1 File-LENNR1123 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 3 (Series I) GENERAL INFORMATION Floor Area,...,.,-,,, ...;, 3771 sf Volume ..................... 43366 cf Front Orientation.......... Front Facing Sizing Location..........,.. LA QUINTA Latitude ................... 33.8 degrees Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... Ill F Summer Inside Design....... 75 F Summer Range ............... 34 F Interior Shading Used...... Yes Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.24 HEATING AND COOLING LOAD SUMMARY 180 deg (S) Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 31385 14522 Glazing Conduction and Solar..... 12074 14870 Infiltration ..................... 12263 7090 Internal Gain .................... n/a 2750 Ducts ............................ 8876 7124 Sensible Load .................... 64597 46356 Latent Load ...................... n/a 11172 Minimum Total Load 64597 57527 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. D'N(3 FOR P, ETy DAP coNsrR ��D SATE �QN �� ay HVAC SIZING HVAC Page 4 Project Title.......... Lennar Homes Plan 3 Date..01/10/14 12:20:30 MICROPAS8 v8.1 File-LENNR1123 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 3 (Series I) GENERAL INFORMATION Floor Area ................. 3771 sf Volume........... 43366 cf Front Orientation. .... . ..I., Front Facing 270 deg (W) Sizing Location.......,.,.:... LA QUINTA Latitude ................... 33.8 degrees Winter Outside Design......;..: 26 F Winter Inside Design...._..::.;:.: 70 F Summer Outside Design....::,:... Ill F Summer Inside Design..,.. .» 75 F Summer Range...... 34 F Interior Shading Used...... Yes Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 31385 14055 Glazing Conduction and Solar..... 12074 15878 Infiltration,.:,.::.., ,,:,...,.. 12263 7090 Internal Gain .................... n/a 2750 Ducts.;,..:, 8876 7223 Sensible Load .................... 64597 46996 Latent Load ...................... n/a 11326 Minimum Total Load 64597 58322 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment C/ I r U�� e��D/N� Fp PP�o FT DEPTH, CpNSTR c.D DATE ION ey CERTIFICATE 'OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 1 Project Title. Lennar Homes - Plan 4 Date..01/10/14 12:20:36 Project Address.;..:,,,,.,:....,. Belmont Collection ****** ............. La Quinta, California *v8.1* Documentation Author... Rick Maurer ****** Building Permit # Rick Maurer Title 24, Inc. 7544 E Saddlehill Trail Plan Check Date Orange, CA 92869 714-771-1507 Field Check Date Climate Zone-,,.,.15 Compliance Method...... MICROPAS8 v8.1 for 2008 CEC.:Standards (r04) MICROPAS8 v8.1 File-LENNR1124 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 4 (Series I) ................. _ _ .... ...__ ..................._... MICROPAS8 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/sf-yr) Design Design Margin Improvement Space Heating.... .,. 5.13 c-<1.41 -37.9% Space Cooling..... ,..s.. i7,2;-„ - 70.59 7.03 9.1% Ventilation Fans. 0.61 0.00 0.0% Water Heating.... 7,41 6.43 3.31 34.0% North Total 82.76 8.93 9.7% Space Heating......,:.:. 3 72 5.94 -2.22 Space Cooling.... ..... 77 75.27 2.35 Ventilation Fans. . _, U d 0.61 0.00 Water Heating... .i1 9 74 6.43 3.31 Waist Tate 1$ . 25 3.4 4 Space Heating.... 3 72_ 5.5:8i -1.86 Space Cooling.,;_.. X77 2� 7.11 Ventilation Fans.. t1 6,Z 01. 0.00 Water Heating.... 9 «:43' 3.31 South Total .......... 91.69 83.13 8.56 SpaceHeating.......,.. Space Cooling... Ventilation Fans........... Water Heating..... «;.,; West Total -59.7% 3.0% 0.0% 34.0% 3.8% -50.0% 9.2% 0.0% 34.0% 9.3% 3.72 5.37 -1.65 -44.3% 77.62 74.89 2.73 3.5% 0.61 0.61 0.00 0.0% 9.74 6.43 3.31 34.0% 9169....., 87.30 4.39 4.8% *** Building complies with Computer Performance *** *** HERS Verification Required fo8`rCompliance *** F oPP CEP Quifvr colv$rRU�[ '6 DATE Cal `- gY Electronically Signed At..$EMR ;p by James Jenike (Lennar Homes) - 1/10/2014 4:24:51 PM Electronically Filed byRiek Mav aid Authenticated at CHEERS.com - 01A0/2014 01:40 PM Registered with CHEERS on I114}/2U1414t)i32 PM' Registration Number. 413-N0012979B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 Project 'Title......;.:;,: ;. Lennar nViRes Y1dn Y La I.C.. V1/ LV/ 1Y J_ . GV. JL MICROPAS8 v8.1 File-LENNR1124 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 4 (Series I) GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 3745 sf Building Type .............. Single Family Detached Construction Type ......... New Natural Gas at Site ....... Yes Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type:..;.. Slab On Grade Number of Building Zones.,.. 1 Conditioned Volume 41195 cf Slab -On -Grade Area.,".... .... 3745 sf Glazing Percentage.:,,:. ,,:.., .,;..;., 27.8 % of floor area Average Glazing U-factor.:;;. 0.35 Btu/hr-sf-F Average Glazing SHGC. 0.25 Average Ceiling Height 11 ft BYIILDEI 'Ii+iil ..INFORMATION Floor # of #,of",fond- Thermo- Vent Vent Verified Area Volume Dwell Peop-" it- stat Height Area Leakage or Zone Type (sf) (cf) Units le' ioned Type (ft) (sf) Housewrap Residence 3745 41195 L. Q0 , E} YetSeYck. 2.0 Standard No • _ ATM :.Aka RKiiwlE° .t?ETAZ. ;Y3; tT R- R- Roof Roof Value Value Vent Mass Rise 1eCt- y Pep Above Below Area Vent Roof Type (lb/sgft) ai3ca Deck Deck Ratio High Tile Heavy 3:12 0.16 0.89 3.5 24 oc 0.00 0.00 1/300 0.30 C/Ty OP s�c)�/ ANT F Ppj j� ��CEP CONSTR V Eb DATE �ON �� ey Electronically Signed at CHEERS.com by James 7t�nike'(Lennar Homes)-1/10/2014 4:24:51 PM Electronically Filed by Rick Maurer atttl,A dijb� at CHEERS.com - 01/10/2014 01:40 PM Registered with CHEERS on 1/10/2014 1:40 32 PNi *0gktmtion Number: 413-N0012979B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3 Project Titie:. .....:. ALeIInar names rlar, s Date..vi.f l.v/ i-s ie-:Z-V J. MICROPAS8 v8.1 File-LENNR1124 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 4 (Series I) OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains JA4 Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments _.. _.. . 1 Wall Wood 527 0.069 21 0 0 90 Yes 4.3.1 A6 Front 2x6 Wall 2 KneeWall Wood 100 0.069 21 0 0 90 Yes 4.3.1 A6 Attic KneeWall 3 Wall Wood 219 0.095 15 0 0 90 No 4.3.1 A4 Gar. Wall 4 Wall Wood 393 0.069 21 0 90 90 Yes 4.3.1 A6 Left 2x6 Wall 5 KneeWall Wood 30 0.069 21 0 90 90 Yes 4.3.1 A6 Attic KneeWall 6 Wall Wood 112 0.095 15 0 90 90 No 4.3.1 A4 Gar. Wall 7 Wall Wood 228 0.069 21 0 90 90 No 4.3.1 A6 Gar. 2x6 Wall 8 Wall Wood 702 0.069 21 0 180 90 Yes 4.3.1 A6 Back 2x6 Wall 9 Wall Wood 633 0.069 21 0 270 90 Yes 4.3.1 A6 Right 2x6 Wall 10 AtticRad Wood 3745 0.025 38 0 n/a 0 Yes 4.2.1 A21 Vented Attic 11 Door Wood 24 0.500 0 0 0 90 Yes 4.5.1 A4 Front Door 12 Door Wood 21 0.500 0 0 0 90 No 4.5.1 A4 Garage Door PERIMETER LOSSES Appendix Length F2 I1s� Solar JA4 Location/ Surface (ft) Factor R Gains Reference Comments 13 SlabEdge 366 0.730 R-0/0in' No 4.4.7 Al Standard Slab Edge FENESTRATIC a iC£ Area U- Act Shade Orientation (sf) factor';SHGC£Aim Till `Type Location/Comments . ..... 1 Wind Front {N)i 8.0 0.350 0.250 0 90 Standard FGLASSI 2 Wind Front '.(N 36.0 0.350 0.250 0 90 Standard FGLASS2 3 Wind Front ''.(N:}r 12.0 0.350 0.250 0 90 Standard FGLASS3 4 Wind Front ,(:N}: 36.0 0.350 0.250 0 90 Standard FGLASS4 5 Wind Front (N;)8.0 0.350 0.250 0 90 Standard FGLASS5 6 Door Front {N;j` 96.0 0.350 0.250 0 90 Standard FGLASS6 7 Wind Front (N} 36.0 0.350 0.250 0 90 Standard FGLASS8 8 Wind Front .(N); 9.0 0.350 0.250 0 90 Standard FGLASS9 9 Wind Left (.E)' 36.0 0.350 0.250 90 90 Standard LGLASSI 10 Wind Left (>E.) 9.0 0.350 0.250 90 90 Standard LGLASS2 11 Wind Left {Ej' 24.0 0.350 0.250 90 90 Standard LGLASS3 12 Wind Back (Sr): 36.0 0.350 0.250 180 90 Standard BGLASSI 13 Wind Back (S) 54.0 0.350 0.250 180 90 Standard!­$GLASS2 14 Wind Back i :j'; 9.0 0.350 0.250 180 90 Standard 4GI:A6'S3 FOR CO I� ��PT ogrE STRUC7 O Htrom $iggnn$ at CHEERS.com by lames;Jmtke %��r Homes)-1/10/2014 4:24:51 PM S11t�j nt y: iMd by Rick Maurer and AptttciiliC6t�d ofCMRS.com - 01/10/2014 01:40 PM Regist*' AwQt CH H ?i(S c i'1/10/20141:40:32 PM 1 er: 413-N0012979B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 YrOjeCL Lennar domes -• rian 4 LdLe..Vl/1V/lY 1/- LV:.3K MICROPAS8 v8.1 File-LENNR1124 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 4 (Series I) FENESTRATION SURFACES _. _ ... Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments 15 Wind Back (;S,) 36.0 0.350 0.250 180 90 Standard BGLASS4 16 Wind Back {S} 36.0 0.350 0.250 180 90 Standard BGLASS5 17 Door Back (S;_}: 192.0 0.350 0.250 180 90 Standard BGLASS6 18 Wind Back (S) 12.0 0.350 0.250 180 90 Standard BGLASS7 19 Door Back (;S) 40.0 0.350 0.250 180 90 Standard BGLASS8 20 Wind Back t'S): 18.0 0.350 0.250 180 90 Standard BGLASS9 21 Wind Back FRS.;} 36.0 0.350 0.250 180 90 Standard BGLASS10 22 Wind Back '4Sj 36.0 0.350 0.250 180 90 Standard BGLASS11 23 Door Right (W) 48.0 0.350 0.250 270 90 Standard RGLASSI 24 Wind Right (:W):.. 9.0 0.350 0.250 270 90 Standard RGLASS2 25 Wind Right `tW) 24.0 0.350 0.250 270 90 Standard RGLASS3 26 Wind Right {}: 6.0 0.350 0.250 270 90 Standard RGLASS4 27 Wind Right (W.); 18.0 0.350 0 250 270, 90 Standard RGLASS5 28 Door Right (Xj' 96.0 0.350 0 25`9.270 90 Standard RGLASS6 29 Wind Right (;>) 24.0 0.350 0.2527;0 90 Standard RGLASS7 Window Overhang Area - Left Right Surface (sf) Width Height Depth Height Extension Extension 1 Window n/a n/a 3 Window 12.;0� ` 7, :.Q n/a n/a 5 Window $ ..0 rt a 4 0 . a 2_; b n/a n/a 6 Door 96.d n1a(} a,;� 1 :. 910 `„;I.''' n/a n/a 7 Window 360.0 1. f , €% 1.,5A,, 0 n/a n/a 8 Window 9.0 n/a 1.5 1.5 2.0 n/a n/a 9 Window 36.0 n/a 6.0 1.5 4.0 n/a n/a 10 Window 9.0 n/a 1.5 1.5 2.0 n/a n/a 11 Window 24.0 n/a 4.0 2.0 4.0 n/a n/a 12 Window 36.0 n/a 6.0 1.5 2.0 n/a n/a 13 Window 54.0 n/a 6.0 1.5 2.0 n/a n/a 14 Window 9.0 n/a 1.5 1.5 2.0 n/a n/a 15 Window 36.0 n/a 6.0 1.5 4.0 n/a n/a 16 Window 36.0 n/a 1.5 10. 1.0 n/a n/a 17 Door 192.0 n/a 8.0 10. 3.0 n/a n/a 18 Window 12.0 n/a 1.5 10. 1.0 n/a n/a 19 Door 40.0 n/a 5.0 10. 3rO --fin/a n/a 20 Window 18.0 n/a 1.5 1.5 2.O e1 n{a n/a 21 Window 36.0 n/a 6.0 1.5 4.0 i_ n 22 Window 36.0 n/a 6.0 1.5 4.03VILDI�n �a (,,�n'�/�a�` 23 Door 48.0 n/a 8. 0 10. 1.0 n/a-& Wp-rn/,a 7'A I FoPPR®V Y OCP-r R CONSED ogTE N Electronically Signed at CHE S tit TBtt § Jait ka (i ttn8r Homes) -1 /10/2014 4:24:51 PM Electronically Filed by Reek 1ti+ltt�e At tthcstitiet�ttsd at CHEERS.cam - 01/10P2014 01:40 PM Registered with CHEERS on 1ll0 itli4 t 40, 3 PM d�WumWr. 413-N001297913-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5 Project Title.-- .:,; Lennar Homes Plan 4 Date..01/10/14 12:20:3E MICROPAS8 v8 1 File-LENNR1124 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 4 (Series I) OVERHANGS —Window—: " "Overhang Area Left Right Surface (sf) Width Height Depth Height Extension Extension 24 Window 9.0 n/a 1.5 10 3.0 n/a n/a 27 Window 18.0 n/a 6.0 13. 2.0 n/a n/a 28 Door 96.0 n/a 8.0 13. 2.0 n/a n/a SLAB SURFACES Area Slab Type (sf) Standard Slab 3745 HVAC SYSTEMS Verified Verifietierfied Verified Verified Maximum System Minimum �R-rag.Charge Adequate Fan Watt Cooling Type Efficiency EER o>': CID Airflow Draw Capacity Furnace 0.800 AFUE n/a` n/a n/a n/a n/a ACSplit 13.00 SEER 11.5 No Yes Yes No HY :RING V ... F Verified Total Sens:able DeS gn Maximum H ding ' .t Dooing =' Coti'ing Cooling System Load Lc Ca�rac�t Capacity Type (Btu/hr) Furnace 68824 n/a n/a n/a ACSplit n/a 56101 69621 _n/a Orientation of Maximum..:..- Front Facing 270 deg (W) Sizing Location.. ... LA QUINTA Winter Outside Design...;.:;:: 26 F Winter Inside Design....:.:. 70 F Summer Outside Design...,... 111 F Summer Inside Design.......,., 75 F Summer Range.................34_F FLU, nor O yr APT ogTF R�CTCN �� ey Electronically Signed at CHEERS.com by belies Jenikbp�o*.!Hbmes)-1/10/2014 4:24:51 PM Electronically Filed by Rick Maurer and Anthen4datod at.Cl4EM.com-01/10/201401:40PM Registered with CHEERS on 1/10/2014 1:40 32 PM4108i alr*,o Idgtstwr: 413-N0012979B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 6 ._ r, _ A Al /I A /'1 A I n AA. 7L 'ro]ecL Title Lennar nontes rlan -1 Liate 01� Iv/ 14 12-:20.ae MICROPAS8 v8.1 File—LENNR1124 Wth—CTZ15S08 User#—MP0357 User —Rick Maurer Title 24, Inc Run —Plan 4 (Series I) DUCT SYSTEMS _. Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R—value Leakage Area Ducts Furnace ........... Attic R-6 Yes No No ACSplit Attic R-6 Yes No No FAN SYSTEMS Flow Power System Type (cfm) (W/cfm) Standard 74.95 .25 WATER HEATING SYSTEMS 77 Number Tank External Heater in Energy Size Insulation Tank Type Type Distribut-AaM- System Factor (gal) R value ............ 1 SmallInstanta Gas Recirc/DemandManual 2 .82 n/a R-n/a SPECIAL FEATURES .:AND .`MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and,,CEC,spec4ifications, and *** *** verified durinplan.chek and fiend iinspection. *** This is a multiple orientation building This printout is for the front facing North..)_>, This building incorporates a Radiant Barrier. This building incorporates a Cool Roof. This building incorporates a non-standard Water Heating System. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** OATF RCT/dN �ey Electronically Signed at CHEERS.com by James Jenike (Lennar Homes) -1 /10/2014 4:24:51 PM Electronically Filed by Rick Maurer and Authenticated at CHEERS.com - 01/10/2014 01:40 PM Registered with CHEERS on IllW2014 1:40:32 PM' Registration Number. 413-N0012979B4000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7 Project 11Lle►i: lennaL nulrles rian Y LaLe. . Vl/ 1V/ i'3 1G.GV. J[ MICROPAS8 v8.1 File-LENNR7.124 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 4 (Series I) HERS REQUIRED VERIFICATION This building incorporates HERS verified High Energy Efficiency Ratio (EER). This building incorporates HERS verified Air Handler Fan Watt Draw. If a cooling system is not installed, then HERS verification is not necessary,4. This building incorporates HERS verified Cooling Coil Airflow. If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. .:REMARKS 1) This house will have Cool Roof rated concrete tiles with .16 minimum aged reflectance and `89„-minimum emissivity. 2) All hot water lines will be insula x per Sec. 150(J) with a minimum of 1 inch insulation.'' This is an addition to the insulation required by the mandatory requirements. 3) The water heaters for this house will have a hot water demand type recirculatng systemwith- manualc�ontrol. 4 ) This house will have two tank.] ess water ;heaters with an energy factor of .82 6f greater`` -"and sized per=the owner's specifications. 5 ) All windows and glass, 1dt brs= w' l f have," nbn=metal frames with a weighted average NFRC U-factor of .35 or less and a weighted average SHGC of .25 or less with high performance Low—E (Max) glass. �/J_�\P� Fo P,P,+�� �FoFPL4 '� o GCNSTR ��,6 qrF /QN \ BY Electronically Signed at CHEERS.com by James Jenike (Lennar Homes)-1/10/2014 4:24:51 PM Electronically Filed by Rick Maurer and Authenticated at CHEERS.com - 01/10/2014 01:40 PM Registered with CHEERS on 1/10/2014 1:40:32 PM * Registration Number: 413-N0012979B-000000000-0000 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 8 Project Title... Lennar Homes Plan 4 Date..01/10/14 12:20:36 MICROPAS8 v8.1 File-LENNR1124 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 4 (Series I) COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... Name.... Rick Maurer Company. Lennar Homes "` "` Company. Rick Maurer Title 24, Inc. Address. 980 Montecito Drive,#302 Address. 7544 E Saddlehill Trail Corona, CA 92879 Orange, CA 92869 Phone... (951) 817-3565 Phone... 714-771-1507 License. Signed.. (;date) . ENFORCEMENT AGENCY,;v Name... Title Agency.., Phone... Signed.,: tdate} _. ca-y QF AP u & SgFk �N-rA FOR co R®I/� QEpT DgTE 57RUCTI� �� ey Electronically Signed at CHEERS.com byy Jal ' 'X I ;:{Lcnn it Homes)-1/10/2014 4:24:51 PM Electronically Filed by Rick Maurer anti Auto At CHEERS.com - 01/10/2014 01:40 PM Registered with CHEERS on 1/10/2014 l 40 32 PM * Ration Number. 413-N0012979B-000000000-0000 HVAC SIZING HVAC Page 1 Project Title.......... Lennar Homes - Plan 4 Date..01/10/14 12:20:36 Project Address........ Belmont Collection ****** La Quinta, California *v8.1* ****** Documentation Author... Rick Maurer .,,Building Permit Rick Maurer Title 24, Inc. 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Check/ Date Climate Zone........... 15 Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r04) MICROPAS8 v8.1 File-LENNR1124 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 4 (Series I) GENERAL INFORMATION Floor Area ................. 3745 sf Volume ..................... 41195 cf Front Orientation.......... Front Facing 0 deg (N) Sizing Location............ LA QUINTA Latitude... 33.8 degrees Winter Outside• Design.......,...., 26 F Winter Inside Design.....:,,;.; 70 F Summer Outside Design..*__.: 111 F Summer Inside Design.......:>.: 75 F Summer Range ............... 34 F Interior Shading Used.;..:.;.. Yes Exterior Shading Used.-.,, .:4 Yes Overhang Shading Used.:.:.:-.. Yes Latent Load Fraction....:.;:- 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) ........... _.. Opaque Conduction and Solar...... 31173 13601 Glazing Conduction and Solar..... 16016 18188 Infiltration ..................... 12178 7041 Internal Gain .................... n/a 2750 Ducts......... _ 9457 7551 Sensible Load .................... Latent Load ...................... 68824 // (, n-a� 49131 11841 Minimum Total Load Note: The loads shown are only one of the of HVAC equipment. Other relevant de requirements, outside air, outdoor des�il availability of equipment, oversizing s considered. It is the HVAC designer's z factors when selecting the HVAC equipment. e,6.8'824 UF 160971 iQ 4 .`�` SAPAZ ri itea-affert t ng Phi T e , tion gn f-a2ct�ors sueair- flow temperature�a�C`c�o�.1 sizing, margin, etc., must also be pansibi-lity,9, co all . HVAC SIZING HVAC Page 2 _ __ . Project Title.......... Lennar Homes Plan 4 Date..01/10/14 12:20:36 ....... MICROPAS8 v8.1 File-LENNR1124 Wth-CTZ15S08 [:EUser:#-MP0357.. User -Rick Maurer Title 24, Inc Run -Plan 4 (Series I) GENERAL INFORMATION Floor Area......... ,.:..;:. 3745 sf Volume .................... 41195 cf Front Orientation.......,;.;.:. Front Facing 90 deg (E) Sizing Location.............:.. LA QUINTA Latitude.. ....:....>»»;::.::. 33.8 degrees Winter Outside Design...>...: 26 F Winter Inside Design.. ::..:- 70 F Summer Outside Design... Ill F Summer Inside Design....;,.:,. 75 F Summer Range...........,.,... 34 F Interior Shading Used...... Yes Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 31173 13866 Glazing Conduction and Solar..... 16016 23767 Infiltration............ ....... 12178 7041 Internal Gain .................... n/a 2750 Ducts ............................ 9457 8612 Sensible Load .................... 68824 56036 Latent Load ...................... n/a 13505 Minimum Total Load 68824 69541 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. QTY F eUi�°LNG s, Qt i/N- ` CFoR (�NSRT��D ©ATE INN `_ QY HVAC SIZING HVAC Page 3 Project Title.......... Lennar Homes Plan 4 Date..01/10/14 12:20:36 ... ..__ MICROPAS8 v8.1 File-LENNR1124 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 4 (Series I) is GENERAL INFORMATION Floor Area ................. 3745 sf Volume ..................... 41195 cf Front Orientation.......... Front Facing 180 deg (S) Sizing Location............ LA QUINTA Latitude. ;. :.... 33.8 degrees Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... Ill F Summer Inside Design....... 75 F Summer Range.;;. .::.. 34 F Interior Shading Used,..,....... Yes Exterior Shading Used...... Yes Overhang Shading Used.:,_... Yes Latent Load Fraction....... 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 31173 13615 Glazing Conduction and Solar..... 16016 18192 Infiltration ..................... 12178 7041 Internal Gain .................... n/a 2750 Ducts ............................ 9457 7554 Sensible Load:.............:.:.. ..:.. 68824 49152 Latent Load ...................... n/a 11846 Minimum Total Load 68824 60997 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. ram_ C17-Y � & � QU���p�s�FE�, flEPT� OF? CONS YEF6 pgTF Tip N _ BY HVAC SIZING HVAC Page 4 Project Title.......... Lennar Homes -' Plan 4 Date..01/10/14 12:20:36 ...... ..... MICROPAS8 v8.1 File-LENNR1124 Wth-CTZ15S08 User#-MP0357 User -Rick Maurer Title 24, Inc Run -Plan 4 (Series I) GENERAL INFORMATION Floor Area........... .. l!. Volume............... Front Orientation...........,.:, Sizing Location .......... Latitude ............... rv;.:.:_. Winter Outside Design.::._.,. Winter Inside Design..:...;, Summer Outside Design. Summer Inside Design... Summer Range.......... o;.'. Interior Shading Used.,,...., Exterior Shading Used;.:.._,;.,, Overhang Shading Used.,:,..,..,.;,:. Latent Load Fraction....... 3745 sf 41195 cf Front Facing 270 deg (W) LA QUINTA 33.8 degrees 26 F 70 F 111 F 75 F 34 F Yes Yes Yes 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... Glazing Conduction and Solar..... Infiltration ..................... (�Intyew.rnal Gain........ «:,«:,«.« ;l�:F:LFhr i:...`asi • • • • w r . w•si:r s •<r••ri-• «-tar w r •-;+ . •.. -.': Sensible Load .................... LatentLoad ...................... Minimum Total Load 31173 13919 16016 23769 12178 7041 n/a 2750 9457 8622 68824 56101 n/a 13520 68824 69621 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. C/ r Q� NQ FpRcoRZ�6 EPAoqr U F N � ey .2008 Joint Appendices JA4-25 4.3 Walls `'Table 4.11- LI-factors of Wood Framed Walls Nominal Rated Rrvalue of Continuous Insulation 2 CavftY Framing R-0 R-2. R4 I" 1:1-7R- UeMMj maul M She /! ; ..: B ...::.. C D E F # i 6 in OC None Any V 0.356 0208 0.147 0.114 0.102 0.093 0.078 0.059 , R-11 belt 2x4 2 0.110 0.090 0-076 0.066 " 0.062 0.059 0.052 0.043 R-13 ball 2x4 3 0.102 . OA85 0A72 0.063 0.060 0.056 0.050 0.042 R-15 batt' 2x4 4 0.080 0.069 0.061 0.057 0.054 0.049 0.041 R-19 bait 2x6 '5 0.074 0.064 0.057 0.051 0.049 0.046 0.043 0.036 R-21 bait' 24 6 0.069 OA61 0.054 30.049 0.047 0.044 0.041 0.035 R-19 bait 2x8 7 0.065 OA56 0.052 0.047 0.045 0.043 0.039 0.034 R-22 ball W 8 0.061 0A54 OA49 0.045, 0.043 0.041 0.038 0.033 R-25 bait 2x8 9 0.057 0.051 0.046 0.042 0.041 0.039 0.036 0.032 R-30 bats 1 2x8 10 0.055 0A50 MM 0.041 0.040 0.038 0.035 0.031 R-30 ball 2x10 11;,_ 0.047 0.043 0.040 0.037 0.035 0.034 0.032 0.028 R-38 batt 2x10 12 0.046 0.042 0.039 0.036 0.035 0.034 0.032 0.028 R-38 ball W 2 13 0.039 0.036 0.034 0.032 0.031 0.030 0.028 0.025 Foamed 2x4 114 0.103 0.085 0.073 0.064 0.060 0.056 0.051 0.042 Plastic or Cellulose 2x6 15 0.071 , 0.062` 0.055 0.050 0.047 0.045 0.042 0.036 Insulation3 2x8 16 OA56 A.050 0.046 0.042 0.040 0.039 0.036 0.031 2x10 17 0.045 0.041 0.038 0.035 0.034 0.033 0.031 0.028< 2xl2 ... 18 0.038 '. 0.035 O.W3 0.031 0.030 0.029 0.028 0.025 24 in. OC None Any 19 0.362 0.210 0.148 0.114 0.102 0.093 _ . . 007.8 0.060 R-11 batt 2x4 �:20 0.106 6.087 .. 0.074 0.065 0.061 0.057 0.051 0.043 R-13 batt 2x4 21 . 0.098 0.082 0.070 0.062 .. 0.058 0.055 0.049. 0.041 R-15 ball 2x4 22 0.091 0.077 ._.. 0.007 ..._ _.__0.059 .......__ ... 0.056 0.053 0.048 0.040 R-19 batt 2x6 23 0.071 0.062 0.055 O.OSd 0 641 .0.641, 0.045 0.042 6.0O6 R-21 bait 2x8 2.4.. _ . 0.066 __.._ OA56 _ ._. 0.052 _ 0.047 ' 0.045 0.043 0.040 0.034 -19 batt 2x8 25 0.063 0.056 6.050 0.046 0.044 0.042- 0.039 0.033 R-22 batt 2x8-,„ 26 0.058 0.052 0.047 0.043 0.041 0.040 0,037 0.032 R-25 ball 2x8 27 0.056 0.050 0.046 0.042 0.040 0.039 0.036 0.031 R-30 batt 1 24 ,28 .. 0.053 0.048,.. _ 0.044 0.040 :....... 0.039 0.037 0.035 0.030 R-30 batt 2x10 29 0.045 „ 0.041 0 038 0.035 0.034 11 0.033 0.031 0.028 R-38 ball 2x10 30 0.044 0.040 0.037 0.035 0.034 0.033 0.031 0.027 R-38 batt 2x12 31 0.038 0.035 0.033%, 0.031 0.030 0.029 0.028 0.025 Foamed 2x4 32 0.099 0.083 0.071 0.062 0.058 0.055 0.050 0.041 Plastic or Cellulose 2x6 33 0.069 0.059 0.054 0.049 O.M 0.044 0.041 0.035 - M f Insulation3 W 34 0.054 0.049 0.044 0.041 d �0�039� .036, O'0350.031 O.Dji�0.�033 COA31QI 2x10 35 0.044 0.040 0.037 0.035 0 027 2xl2 . 36 .0.036 0.034 _ 0.031 0 030 �ii 0.0 �0.028,u24 Tj'1 Notes . W. � R � APT D _CD SQ� . �® 1. Higher density fibs lass batt is required in these cases. . n'g � N CTiDN 2. Continuous Insulation may -be installed on either the inside or the exterior of the wall, o nrb k- 3. Foamed plastic and cellulose stall fi!I._the entire cavity Cellulose shall have a binder to pre nt-saggi F4 Joint Appendix JA4 - U-Factor, C-Factor, and Thermal Mass Data 2008 Joint Appendices JA4-7_ a 4.2 Roofs and Ceilings Table 4-P- 1- U-0actors.of Wood Framed Attic Roofs Rated IR-value of continuous Insulation' R-value of '; Truss AM None R-2 R4 R-6 R-7 R-8 R-10 R-14 ..... 16 In. Oc NO, 1 0.300 0.187 0.136 } 0.107 - 0.097 0.0*88 0.075 058 R-11 2 0.079 0.068 0.060 0.053 0.051 0.048 0.044 0.037 R-13 3 0.071 0.062 0.055 0.050 0.047 0.045 0.041 0.036 R-19 4 0.049 0.045 0.041 0.038 0.037 0.035 0.033 0.029 R-21 Is 0.042 0.039 0.036 0.034 0.032 0.031 0.030 0.026 R-22 6 0.043 0.039 0.037 0.034 0.033 0.032 0.030 0.027 R-25 7 0.038 0.035 0.033 0A31 0.030 0.029 0A28 0.025 R-30 8 0.032 0.030 0.028 0.027 0.026 0.025 0.024 0.022 R-38 =9 0.026 0.024 0.023 0.022. 0.022 0.021 0.020 0.019 R-44 10 0.021 0.020 0.019 0.019 ,, 0.018 0.018 0.017 0.016 R-49 11 0.020 0.019 0.019 0.018 0.018 O.OV 0.017 0.016 R-60 T12 0.017 0.016 0.016 0.015 0.015 0.015 0.014 0.013 24 in. Or.; None 13 0.305 0.189 0.137 0.108 0.097 0.089 0.075 0.058 R-11 14 0.076 0.066 0.058 0.052 0.050 0.047 0.043 0.037 R-13 -15 0.068 0A60 0.054 0.048 0.046 0.044 0-041 0.035 R-19 16 0.048 0.043 0.040 0.037 0.036 0.034 OJIM 0.029 R-21 17 0.043 0.04(Y 0.037 0.034 0.033 0.032 0.030 0.027 R-22 18 0.041 0.038 O.Q36 0.033 0.032 0.'031 0.029 0.026 R-25 19 : r 0.037 0.034 0.032 0.030 0.029 0.028 0.027 0.024 - R-30 20 0.031 0.029 0.028 0.026 0.025 0.025 0.024 0.022 R-38 21 0.025 0.024 0.023 0.022 0.021 0.021 0.020 0.018 R-44 22 0.021 0.020 0.019 0.019 0.018 0.018 0.017 '' 9.016 R-49 23 0.019 `° f 0.019 0.018 0.017 0.017 0.017 0.016 0.015 R-60 24, 0.016 0.016 0.015 0.015 0.014 0.014 0.014 0.013 Notes: 1. Continuous insulation shall be bcated at the ceiling, below the bottom chord of the truss and be uninterrupted by framing. 2. In crimate zones 1 and 16 the insulating R-value of continuous insulation materials installed above the roofs waterproof membrane shall be,multiplied by O.t before'choosing the table column for determining assembly U-factor. r.. This table contains thermal performance data (U-factors) for wood framed attics where the ceiling provides the air barrier and the attic is ventilated. Wood trusses are the most common construction for low-rise residential buildings and for Type V nonresidential buildings. While therske c�h shows a truss system with a flat ceiling, the data in this table may be used for scissor trusses and othel- non Tftmses, If the bottom chord is i not flat, then the slope should not exceed 3:12 for nonadhesive binder blovl�n lnsulfs a also be used with composite trusses that have a wood top and bottom n ch8rd�a�ialaf�strl � s For the majority of cases, values will be selected from column A of this tabl . �iti qr .rk common situation where either batt or blown"insulation is placed dir6ctly oftAf i ing a th edges). Builders or designers may increase thermal performance by adding a coM layer t the ceiling. The continuous insulation is typically a rigid polystyren gr,lyisacyanurate foam on. Continuous insulation does not include the blown or batt insulatio t is a bottom chord of the t (this is already accounted for in the U-factors published in Column A). ... Joint Appendix JA4 - U-Factor, C-Factor, and Thermal Mass Data 2008 Joint Appendices JA4-61 Table 4.4.7- F-Factors for Unheated Slab -on -Grade Floors Rated R-Value of Insulation Insulation Description R-0 R-5 R-7.5 R-10 R-15 R-20 R-25 R-30 R-35 R-40 R-45 R-50 R-55 A° f3. C D. E F G.._ H 1 J K: _ L M None 1 07s ..., 12 In. horizontal 2 0.72 0.71 0.71 0.71 ... 2411n. horizontal ....,. 3 .._........ 0.70 0.70 0.70 0.69 36 in. horizontal 0.68 0.67 066 0.66 48 in. horizontal 5 0.67 0.65 0.64 0.63 12 in. vertical 6 0.61 0.60 0.58 0.57 0.567 0.565 0.564_ 24 in. vertical :7 0.58 0.56 0.54 0.52 0.610 0.505 0.502 36 in. vertical '8 0.66 0.53 0.51 0.48 0.472 0.464 0.460 48 In vertical 9 0 54 0 51 0 48 0.45 0 434 0.424 0 419 Fully IInsulated slab 10 0.46 0.41 0.36 01. .36 0.261 0.233 0.213 0.196. 0.186 0.116. 6.168 0.161 Note: These values are used for slab edge conditions with and without carpet. Figure 4.4.7- Unheated Slab -on -Grade Floor Horizontal insulation is continuous insulation that is applied directly to the underside of the slab and extends inward horizontally from the perimeter for the distance specified or continuous insulation that. is applied downward from the top of the slab and then extends horizontally to the interior or the exterior from the perimeter for the distance specified. Ver&W kL%A-: ttion is continuous insulation that is applied directly to the slab exterior, extending downward from the top of the stab for the distance specified: Fully insulated slab is continuous insulation that extends downward from the top to the slab"artd'abng.the.entire:penm ter and completely covers the entire area under the slab. ,� 4-� cIF W Assumptions: Data of this table is taken from the ASHRAEAESNAFStdo- �d w-.4- t t,vAp�'-di) oq rE STgUCT N ..... .. Joint Appendix JA4 - U-Factor, C-Factor, and Thennal Mass Data 2008 Joint Appendices . ........ . JA4-63 4.5 Miscellaneous Construction Table 4.5.1 — Opaque Doors DesedpUon U-factor (Btu/RF-M A Uninsulated single -layer metal swinging doors or non-swingingdoors, including single -layer ^t 1A5 uninsulated access hatches and uninsulated smoke vents: ... .. ..... - UnInsulated double -layer metal swinging doors or non -swinging doors, including double -layer 2 0.70 uninsulated access hatches and.. urdrisulated smoke vents: Insulated metal swinging doors, including fire -rated doors, insulated access hatches, and insulated -3 0.50 smoke vents: .... . .... . ... V4;od d;;;. minimum nominal thickness of 1-3/4 In. (44 mm), including panel doors with minimum 4 -1/8 in. (28 mm , and sold core flush doors, and core, panel thickness of 1. flush doors. Any other wood door- 5 . .......... 0.60 Uninsulated single layer metal roll.up doors including fire rated door .!6 1.45 Insulated single layer metal secdonal doors, minimum insulation nominal thickness of I-WS Inch. 0.179 expanded -4.pe ,polystyrene (R . ... . sourte':' A61HIME 90.1-2004 11 . Section. A7. 0 OR CO 0 *VQ kzp'r /- r R J01r)t APPendix JA4 7 U-Factor, C-FaCtOr, and Thermal Mass Data Appendix D 2008 Residential Appendices RA4 D-1 j Appendix D Eligibility Criteria for Radiant Barriers, Section RA4.2.2 Radiant barriers shall meet specific eligibility and installation criteria to be modeled by any ACM and receive energy credit for compliance with the energy efficiency standards for low-rise residential buildings. The emittance of the radiant barrier shall be less than or equal to 0.05 as tested in accordance with ASTM C-1371 or ASTM E-408. Installation shall conform to ASTM C-1158 [Standard Practice For Use and Installation Of Radiant Barrier Systems (RBS) In Building Construction.], ASTM C- 727 (Standard Practice For Installation and Use Of Reflective Insulation In Building Constructions.), ASTM C-1313 (Standard Specification for Sheet Radiant Barriers for Building Construction Applications), and ASTM C-1224 (Standard Specification for Reflective Insulation for Building Applications). The radiant barrier shall be securely installed in a permanent manner with the shiny side facing down toward the interior of the building (ceiling or attic floor). Moreover, radiant barriers shall be installed at the top chords of the roof truss/rafters in any of the following methods: 1. Draped over the truss/rafter (the top chords) before the upper roof decking is installed. 2. Spanning between the truss/rafters (top chords) and secured (stapled) to each side. 3. Secured (stapled) to the bottom surface of the truss/rafter (top chord). A minimum air space shall be maintained between the top surface of the radiant barrier and roof decking of not less than 1.5 inches at the center of the truss/rafter span. 4. Attached [laminated] directly to the underside of the roof decking. The radiant barrier shall be laminated and perforated by the manufacturer to allow moisture/vapor transfer through the roof deck. In addition, the radiant barrier shall be installed to cover all gable end walls and other vertical surfaces in the attic. The attic shall be ventilated to: 1. Conform to the 2. Provide a minin square foot of v 3. Provide no less Ridge vents or gable -end vents are The material should be cut to allow ant barrier manufacturer's instructions. 1 free:ventilation area of not less than one area.for eac 0 50 ftz-of attic floor area. � 0,per'��r �� � e n 30 peccent�upper ventsl/VrN - full a The radiant barrier (except W-radiant barriers la-M Mated d roof deck) shall be installed to have minimum gap of 3.5 between the bottom of the radiant barer and -the -top of th insulation to allow ventilation air to flow between the=roof -c to the ceiling ckinq and 2008 Residential Compliance Manual August 2009 ix D ... 2008 Residential Appendices RA4 D-2 the top surface of the radiant barrier, and have a mini11 mum of six (6) inches (measured horizontally) left at the roof peak to allow hot air to escape from the air space between the roof decking and the top surface of the radiant barrier. • When installed in enclosed rafter spaces where ceilings are applied directly to the underside of roof rafters, a minimum air space of 1 inch shall be provided between the radiant barrier and the top of the ceiling insulation, and ventilation shall be provided for every rafter space. Vents shall be provided at both the upper and lower ends of the enclosed rafter space. • The product shall meet all requirements for California certified insulation materials (radiant barriers) of the Department of Consumer Affairs, Bureau of Home Furnishings and Thermal Insulation, as specified by CCR, Title 24, Part 12, Chapter'12-13, Standards for Insulating Material. • The use of a radiant barrier shall be listed in the Special Features and Modeling Assumptions listings of the CF-1 R and described in detail in the ACM Compliance Supplement. See Figure 3-11 for drawings of radiant barrier installation methods,: Air Ra Ba Ins Method 1: Radiant Barrier Draped Method 2: Radiant BarderAttached Over Top of TruadRaRer Between TruelRafters Roof Decking Roof Decking Rafter Radiant Barrier Joist Method 3: Radiant BarderAttached to Bottom of Tri offitafter Barrier ' Method 4: Radiant BarderAttache Underside,of,Roof Deck Figure 3-11— Methods of Installation for Radiant Barriers '�f f7A ®EPr 2008 Residential Compliance Adainual August 2009 MICROPAS8 Fa w F.ST %"" "1, VALUF.IS Table 2.4. Default Fenestration Product U-Factors (this table to be used by manufacturer's to establish a U-factor rating without performance testing) Single Pane Double Pane' GlassZ Frame Type) Product Type U-factor U-factor Block Metal Operable 128 0.79 0.87 Metal Fixed 1.19 0.71 0.72 Aida) Grccnbouse/Gardcn window: 2.26 1.40 Metal Doors 125 0.77 Metal Skylight 1.98 130 Metal. Thermal Break Operable 0-66 Metal, Thermal Break Fixed 0.55 Metal, Thermal Break Grcenhouse,Garden window 1.12 Metal, Thermal Break Doors 039 Metal, Thermal Break Skylight 1.11 Non -Metal Operable 0.99 0.58 0.60 Non -Metal Fixed 1.04 0.55 0.57 Non -Metal Doors 099 053 Non-Mdal Greenhouse/Garden windows 1.94 1.06 Non -Metal Skylight IA7 0.84 1. For all dual glazed fenestration products, adjust the listed U-factors as follows: a. Add 0.05 for products with dividers between panes if spacer is less than 7.'16 inch widc- b. Add 0.05 to any product with true divided cite (dividers through the panes). 2. Transluscent or transparent panels sha!l use glass block values. Table 2 5. Default Solar Heat Gain Coefficient Total Window SHGC Single Double Glass Frame Type Product' Glazing Pane Pane Block' Metal Operable Clear 0.80 0.70 0.70 Metal Fixed Clear 0.83 0.73 0.73 Metal Operable Tinted 0.67 0.59 Metal Fixed Tinted 0.68 0.60 Metal, Thermal Break Operable Clear 0.63 Metal, Thermal Break Fixed Clear 0.69 Metal, Thermal Break Operable Tinted 0.53 Metal, Thermal Break Fixed Tinted 0.57 Non -Metal Operable Clear 0,:34 0.65 0.70 Non -Metal Fixed Clear 0.76 0.67 0.67 Non -Metal Operable Tinted 0.60 0.53 Non -Metal Fixed Tinted 0.63 055 SHGC = Solar Heat Gain Coefficient 1. Transluscent or transparent panels shall use glass block values. NhOTE Lo� G Tablfault SHGC. a Ify d� o not have N RC value for the SHGC, use clearw f lass isrnot-a,UnMd product 2 -3 V COMPLIANCE 1211160200940R CON0 v���`by Enercomp, InC oArE UC7-/QN ......_ All windows and _glass doors will, have non-metal frames with a weight r ver ge Wkib U-factor of .35 or less and a weighted average SHGC of .25 or less: high performance Low-E (Max) glass. 5�7zf c—� n 1 VI 2-4 l�- t 19leM 4 xz- ryl.,3rJ'. ! o Xi ')S- F• jn./3/>. t O x g- = av s' tZvn. )I -A t`' Fa YZ.P" . a Z x }3q,3 1gA� z r�riv t 3 x co = f £f -E? TA to r3,d SKYLICi TSP O KYLt 1.� d {F CAS MAZx co : zy CL) s.EyLI C `�, j GL $IN AREA�- ) J5 2> 6Q. FT. SK, L14j)A c5 1'n onwl nw- to x to = 3 b 2,`'(. = 3O6- L`O X 1 40 ,.-7, 5(w rn , � • 9 x sto I= �-'- )91 tb (o = J S W)t )�°XS��✓(t)F� X?��, CI7-y. et�/Lp/ G &SA L� ���T 4PPR FEN D R COIVSTR ED DgTE pN �_ By k Al LAIMr- r� i .� -N s . i SIN AREA_ PLAN: 3 qF, yyl.r3b. (o(o F. C�.rL�• JZxl�=3���i�. A � 7,»� • % 2. x $'` '. / g '1.- �L� nit • , 3 x! b=13.5(3�) F. 3 x is M Zy ev ;= ► 3 X b= S' KY- U4,lA''fi S _ O TOTAL_ GkLA-41WC,= C7 5EF12►E7r-,1 3�Y X G� - 3 C. t1 �• �T. 14 �.. J Z t KYLt4MTS clFony rn, )e"v. to x ! = 9► r- yy� � 403rV. to x $' - y Ir yY7.!3✓q. to xI"- = 9 . Yie.,.�rneri.4 z�b,= zyC�J b 9 co Y�AV, y Ly(o = Z-4tL 1. Lam} C4 Z- r-. ��.3 3 X CCa =3coC� J ep4•y ZX� --g- 4, Ir 9 5 ►j'WPiLQ,NG & � QUIN7-A ��'� FPI� �� pEPT FOR CO ���E� uCTtON orw sh. tT: .E`Ts 3E,GL 1tt" Age. -*VEr2IFY SOUt4 D ORC)IN,ANCEP. (IF awY) PIZIOfZ To_ AjC SET. LOAD CALCS - BELMONT (Plan 1) GENERAL LIGHTING LOAD..... SQUARE FT 2967 X3 WATTS plsq It 8901 = 8901 SMALL APPLIANCE CIRCUITS (minimum 2) 2 X 1500 EACH 3000 = 3000 LAUNDRY CIRCUITS & TANKLESS WATER HTRS (minimum 1) 3 X 1500 EACH 4500 = 4500 COOKING APPLIANCE (name plate rating) - OVEN 50 AMPS = WATTS 12000. = 12006. COOKING APPLIANCE (name plate rating) 0 AMPS '= WATTS 0 _ 0 COOKING APPLIANCE (name plate rating) COOK TOP 0 AMPS =WATTS 0 = 0 ) COOKING APPLIANCE (name plate rating) 0 AMPS = WATTS. 0 1 =. 0 ELECTRIC DRYER 0 AMPS = WATTS 0 ' _. -0 FIXED APPLIANCE - MICROWAVE 1500 WATTS 1 X 1500 EACH 1500 = .1500 FIXED APPLIANCE '-COMPACTOR 1200 WATTS 0 X 1200 EACH 0 = 0 FIXED APPLIANCE -DISHWASHER 1200 WATTS 1 X 1200 EACH 1200 = 1200 FIXED APPLIANCE- DISPOSAL 600 WATTS 1' X 600 EACH 600 - 600 FIXED APPLIANCE 0 X 600 EACH 0 = 0 FIXED APPLIANCE - CENTRAL VAC 1800 WATTS 0 X 1800 EACH 0 - 0 FIXED APPLIANCE -1800 WATTS 0 X 1800 EACH 0 = 0 FIXED APPLIANCE - 1800 WATTS 0 X 1800 EACH 0 = 0 FIXED APPLIANCE - 1800 WATTS 0 X 1800 EACH 0 = 0 ELEVATOR EQUIPMENT 0 AMPS = WATTS' 0 = 0 POOL EQUIPMENT 0 AMPS = WATTS, 0 =, 0 LIGHTING & APPLIANCE TOTAL__ ...................... _ _............. = 31701 LIGHTING & APPLIANCE TOTAL-10,000 WATTS..... . ... ... ... ... ... = 21701 40% of LIGHTING & APPLIANCE TOTAL - 10,000 WATTS........... = 8680 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) . 5 TONS = WATTS 10000 = 10000 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 5 TONS = WATTS 10000 = 10000 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 0 TONS = WATTS 0 - 0 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 0 TONS = WATTS 0' = 0 TOTAL OF ALL HVAC EQUIPMENT... ... ... ... ... ... ... ... ... ... ... ... ... .. = 20000 10000 WATTS X 100%'............................................................... =' 10000 4800 WATTS FOR NEW HOUSE - PER CLV ORDINANCE = 4800 GRAND TOTAL ................................................. 43480 AMPS REQUIRED 181 j (JJLD1P`!C (jR®IEP VNS-Tt�CT/ DATE '"� By LOAD CALCS - BELMONT (Plan 1 w/Casita) GENERAL LIGHTING LOAD..... SQUARE FT 3271 X3 WATTS p/sq ft 9813 = 9813 SMALL APPLIANCE CIRCUITS (minimum 2) 2 X 1500 EACH 3000 = 3000 LAUNDRY CIRCUITS & TANKLESS WATER HTRS (minimum 1) 3 X 1500 EACH 4500 = 4500 COOKING APPLIANCE (name. plate rating) - OVEN .50 AMPS = WATTS 12000 _ 12000 COOKING APPLIANCE (name plate rating) 0 AMPS '= WATTS 0 = 0 COOKING APPLIANCE (name plate rating) COOK TOP 0 AMPS = WATTS 0 = 0 COOKING APPLIANCE (name plate rating) 0 AMPS= WATTS 0 0 ELECTRIC DRYER 0 AMPS = WATTS 0 = 0 FIXED APPLIANCE - MICROWAVE 1500 WATTS 1 X 1500 EACH 1500 = 1500 FIXED APPLIANCE -COMPACTOR 1200 WATTS 0 X 1200 EACH 0 = 0 FIXED APPLIANCE - DISH WASHER 1200 WATTS 1 X 1200 EACH 1200 = 1200 FIXED APPLIANCE - DISPOSAL 606 WATTS 1 X 600 EACH 600 = 600 FIXED APPLIANCE 0 X 600 EACH 0 - 0 FIXED APPLIANCE - CENTRAL VAC 1800 WATTS 0 X 1800 EACH 0 = 0 FIXED APPLIANCE -1800 WATTS 0 X 1800 EACH 0 = 0 FIXED APPLIANCE -1800 WATTS 0 X 1800 EACH 0 = 0 FIXED APPLIANCE - 1800 WATTS 0 X 1800 EACH 0 = 0 ELEVATOR EQUIPMENT 0 AMPS = WATTS 0 = 0 POOL EQUIPMENT 0 AMPS = WATTS, 0 = 0 LIGHTING & APPLIANCE TOTAL ......... ... ... ............_.. ............... _ 32613 LIGHTING & APPLIANCE TOTAL710,000 WATTS ... ... ............... = 22613 40% of LIGHTING & APPLIANCE TOTAL,- 10,000 WATTS:.......... = 9045 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 5 TONS = WATTS 10000 = 10000 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 5 TONS =WATTS 10000 = 10000 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 3 TONS = WATTS 6000 =. 6000 HEATING & AIR CONDTTIONIG (2000 WATTS TO EACH TON) 0 TONS = WATTS 0 = 0 TOTAL OF ALL HVAC EQUIPMENT .................................. = 26000 10000 WATTS X 100%..............................:.................................. _ 10000 4800 WATTS FOR NEW HOUSE - PER CLV ORDINANCE - 4800 GRAND TOTAL............................................. 49845 AMPS REQUIRED' 208 LDATE l�Gli'C LA t' `-� APi�`�ahE�'DEFT FOR CONS R'c` D UCH'//U1V -_ BY LOAD CALCS - BELMONT (Plan 2) GENERAL LIGHTING LOAD ... :.SQUARE FT 3153 X3 WATTS ptsq It 9459 = 9459 SMALL APPLIANCE CIRCUITS.(minimum 2) 2 X 1500 EACH 3000 = 3000 LAUNDRY CIRCUITS & TANKLESS WATER HTRS (minimum 1) 3 X 1500 EACH 4500 = 4500 COOKING APPLIANCE (name plate rating) - OVEN .50 AMPS = WATTS 12000. = 12000 COOKING APPLIANCE (name plate rating) 0 AMPS = WATTS 0 = 0 COOKING APPLIANCE (name plate rating) COOK TOP 0 AMPS = WATTS 0 = 0 COOKING APPLIANCE (name plate rating) 0 AMPS = WATTS 0 = 0 ELECTRIC DRYER 0 AMPS = WATTS 0 - 0 FIXED APPLIANCE - MICROWAVE 1500 WATTS 1 X 1500 EACH 1500 _ 1500 FIXED APPLIANCE - COMPACTOR 1200 WATTS 0 X 1200 EACH 0 _ 0 FIXED APPLIANCE - DISH WASHER 1200 WATTS 1 X 1200 EACH. 1200 - 1200 FIXED APPLIANCE- DISPOSAL 600 WATTS 1 X 600 EACH 600 = 600 FIXED APPLIANCE 0 X 600 EACH 0 = 0 FIXED APPLIANCE - CENTRAL VAC 1800 WATTS 0 X 1800 EACH 0 - 0 FIXED APPLIANCE - 1800 WATTS 0 X 1800 EACH 0 = 0 FIXED APPLIANCE- 1800 WATTS 0 X 1800 EACH 0 = 0 FIXED APPLIANCE -1800 WATTS 0 . X 1800 EACH 0 = 0 ELEVATOR EQUIPMENT 0 AMPS = WATTS 0 _ 0 POOL EQUIPMENT 0 AMPS = WATTS 0 _ 0 LIGHTING & APPLIANCE TOTAL...... ... ... ... ... .................:.. = 32259 LIGHTING & APPLIANCE TOTAL-10,000 WATTS ..................... = 22259 40% Of LIGHTING & APPLIANCE TOTAL - 10,000 WATTS........... = 8904 HEATING &.AIR CONDITIONIG (2000 WATTS TO EACH TON) 5 TONS = WATTS 10000 = 10000 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 5 TONS = WATTS 10000 = 10000 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 0 TONS = WATTS 0 = 0 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 0 TONS = WATTS 0 = 0 TOTAL OF ALL HVAC EQUIPMENT--- ................................. _ 20000 10000 WATTS X 100%................................................................. _ 10000 4800 WATTS FOR NEW HOUSE = PER CLV ORDINANCE = 4800 GRAND TOTAL ................................................... 43704 AMPS REQUIRED 182 BUILDING & L �i���°�' FE'T-yDEpr� UCTIION LOAD CALCS - BELMONT (Plan 3) GENERAL LIGHTING LOAD..... SQUARE FT 3475 X3 WATTS p/sq ft 10425 = 10425 SMALL APPLIANCE CIRCUITS (minimum 2) 2 X 1500 EACH 3000 - 3000 LAUNDRY CIRCUITS & TANKLESS WATER HTRS (minimum 1) 3- X 1500 EACH 4500 _ 4500 COOKING APPLIANCE (name plate rating) - OVEN 50 AMPS = WATTS 12000 = 12000 COOKING APPLIANCE (name plate rating) 0 AMPS = WATTS 0 = 0 COOKING APPLIANCE (name plate rating) COOK TOP 0 AMPS =WATTS 0 = 0 COOKING APPLIANCE (name plate rating) 0 AMPS = WATTS 0 = 0 ELECTRIC DRYER 0 AMPS = WATTS- 0 = 0 FIXED APPLIANCE - MICROWAVE 1500 WATTS 1 X 1500 EACH 1500 = 1500 FIXED APPLIANCE -COMPACTOR 1200 WATTS 0 X 1200 EACH 0 = 0 FIXED APPLIANCE - DISH WASHER 1200 WATTS 1 X 1200 EACH 1200 - 1200 FIXED APPLIANCE - DISPOSAL 600 WATTS 1 X 600 EACH 600 = 600 FIXED APPLIANCE 0 X 600 EACH 0 = 0 FIXED APPLIANCE - CENTRAL VAC 1800 WATTS 0 X 1800 EACH 0 = 0 FIXED APPLIANCE -1800 WATTS 0 X 1800 EACH 0 = 0 FIXED APPLIANCE -1800 WATTS 0 X 1800 EACH 0 = 0 FIXED APPLIANCE -1800 WATTS 0 X1800 EACH 0 = 0 ELEVATOR EQUIPMENT 0 AMPS = WATTS 0 = 0 POOL EQUIPMENT 0 'AMPS = WATTS 0 - 0 LIGHTING & APPLIANCE TOTAL...... ... ... ... ......... :.. ... ... _ 33225 LIGHTING & APPLIANCE TOTAL - 10,000 WATTS .................. :.. = 23225 40% of LIGHTING & APPLIANCE TOTAL - 10,000 WATTS........... = 9290 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 5 TONS = WATTS 10000 = 10000 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 5 TONS =WATTS 10000 - 10000 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 0 TONS = WATTS 0 = 0 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 0 TONS = WATTS 0' = 0 TOTAL OF ALL HVAC EQUIPMENT ......................................... = 20000 10000 WATTS X 100%................:................................................ = 10000 4800 WATTS FOR NEW HOUSE r PER CLV ORDINANCE _ 4800 GRAND TOTAL ............... .................................. 44090 AMPS REQUIRED 184 CF iING cx ` S�'+�=ETY DEPT. Pr- P 0`�r`�� E CC►��T+�UCTi0- --___ BY LOAD CALCS - BELMONT (Plan 4) GENERAL LIGHTING LOAD.....SQUARE FT 3771 X3 WATTS plsq It 11313 = 11313 SMALL APPLIANCE CIRCUITS (minimum 2) 2 X 1500 EACH 3000 3000 LAUNDRY CIRCUITS & TANKLESS WATER HTRS (minimum 1) 3 X 1500 EACH 4500 = 4500 COOKING APPLIANCE (name plate rating) - OVEN 50 AMPS = WATTS 12000 = 12000 COOKING APPLIANCE (name plate rating) 0 AMPS = WATTS 0 = 0 COOKING APPLIANCE (name plate rating) COOK TOP 0 AMPS = WATTS 0 = 0 f COOKING APPLIANCE (name plate rating) 0 AMPS = WATTS 0 = 0 ELECTRIC DRYER 0 AMPS = WATTS 0 = 0 FIXED APPLIANCE - MICROWAVE 1500 WATTS FIXED APPLIANCE - COMPACTOR 1200 WATTS 1 X 1500 EACH X 1 000 EACH 1500 0 = 1500 - 0 - 0 FIXED APPLIANCE - DISH WASHER 1200 WATTS 1 X 1200 EACH 1200 = 1200 FIXED APPLIANCE - DISPOSAL 600 WATTS 1 X 600 EACH 600 = 600 FIXED APPLIANCE 0 X 600 EACH 0 - 0 FIXED APPLIANCE- CENTRAL VAC 1800 WATTS 0 X 1800 EACH 0 = 0 FIXED APPLIANCE '-1800 WATTS 0 X 1800 EACH. 0 — 0 FIXED APPLIANCE -1800 WATTS 0 X 1800 EACH 0 = 0 FIXED APPLIANCE -1800 WATTS 0 X 1800 EACH 0 = 0 ELEVATOR EQUIPMENT 0 AMPS = WATTS 0 = 0 POOL EQUIPMENT 0 AMPS = WATTS 0 = 0 LIGHTING & APPLIANCE TOTAL ..................................... = 34113 LIGHTING & APPLIANCE TOTAL-10,000 WATTS ..................... = 24113 40% of LIGHTING & APPLIANCE TOTAL - 10,000 WATTS........... = 9645 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 5 TONS = WATTS 10000 = 10000 HEATING & AIR CONDITIONIG (2000.WATTS TO EACH TON) 5 TONS = WATTS 16006 - 10000 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 0 TONS = WATTS 0 0 HEATING & AIR CONDITIONIG (2000 WATTS TO EACH TON) 0 TONS = WATTS 0 - 0 {{ 1 TOTAL OF ALL HVAC EQUIPMENT ......................................... = 20000 10000 WATTS X 100%................................................................. = 10000 4800 WATTS FOR NEW HOUSE - PER CLV ORDINANCE = 4800 GRAND TOTAL ................................................. 44445 AMPS REQUIRED 185 Ty LI�� TA -�� DE APpp- ��D it UCpBA