PGA West - Monterra TR 32742 (Plans 1-4) Title 24 - Revision 211
BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Monterra, Phan 1-Revised
55-101 Monroe
La Quinta, CA 92253
Project Designer:
Helton, DeFord & Associates
17411 Irvine Blvd, Suite O
Tustin, CA 92780
(909) 957-4550
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
77085 Michigan Drive
Palm Desert, CA 92211
(760) 200-4780
Job Number:
Date:
11 /4/2015
CITY OF LA QU'INT�
BUILDING & SAFETY DEPT.
APPROVED
FOR CONST$), CTION
NOV 1 '8 2015
rrVt%ONI NLA tj69hA
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 6.7 by EnergySoft User Number. 6712 ID:
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF-1 R-PRF-01-E Certificate of Compliance
Form RMS-1 Residential Measures Summary
Form MF-1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
Room Load Summary
Room Heating Peak Loads
Room Cooling Peak Loads
1
2
3
13
14
18
20
22
24
EnergyPro 6.7 by EnergySoft Job Number: ID: User Number: 6712 1
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 10:00, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xml
CF1 R-PRF-01
Page 1 of 10
GENERAL INFORMATION
01
Project Name
Monterra Plan 1
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2015
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2013-4 (744)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.6
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
,., Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
3180
15
Number of Zones
2
16
Slab Area (ft2)
3180
17�,,
Number of Stories
1
18
Addition Cond. Floor Area
N/A
19
Natural Gas Available
Yes
20
Addition Slab Area (ft2)
N/A
"21
Glazing Percentage (%)
18.8%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below,
f�
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFiR-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:01:06
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 10:00, Wed, Nov 04, 2015
CF1 R-PRF-01
l I
Page 2 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xml
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.11
0.80
0.31
27.9%
Space Cooling
97.32
89.68
7.64
7.9%
IAQ Ventilation
1.18
1.18
0.00
0.0%
Water Heating
8.07
7.61
0.46
5.7%
PV Credit
----
0.00
0.00
----
North Facing Compliance Total
107.68
99.27
8.41
7.8%
Space Heating
1.11
139
-0.28
25.2%
Space Cooling
97.32
`95.67
1.65
1.7%
IAQ Ventilation
1.18
1.18
0.00
0.0%
Water Heating
8.07
7.61
0.46
5.7%
PV Credit
----
0.00
0.00
----
East Facing Compliance Total
107.68
105.85
1.83
1.7%
Space Heating
1.11
1.77
-0.66
-59.5%
Space Cooling
97.32
' :
86.71
10.61
10.9%
IAQ Ventilation
1.18
"4
1.18
0.00
0.0%
Water Heating
8.07
09
7.61
0.46
5.7%
PV Credit
----
0.00
0.00
----
South Facing Compliance Total
107.68 ',
97.27
10.41
9.7%
Space Heating
1.1 °, j
1.20
-0.09
-8.1 %
Space Cooling
47.32
92.54
4.78
4.9%
IAQ Ventilation
.1.18
1.18
0.00
0.0%
w
Water Heating
r c 8.07
7.61
0.46
5.7%
'
PV Credit
�_> ----
0.00
0.00
----
West Facing Compliance Total
Al�_ 107.68
102.53
5.15
4.8%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
• Exposed slab floor In conditioned zone
Registration Number: a
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:01:06
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1
Calculation Description: Title 24 Analysis
HERS FEATURE SUMMARY
Calculation Date/Time: 10:00, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xml
CF1 R-PRF-01
i t
Page 3 of 10
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Ducts located entirely In conditioned space
Domestic Hot Water System Verifications:
• -- None --
ENERGY DESIGN RATING `" ~
This is the sum of the annual TDV energy consumption for energy use components included in the perforrhAce compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic`appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on -site renewable energy system.
Reference Energy Use
Energy Design Rating
Margin
Percent Improvement
Total Energy (kTDV/f2-yr)•
148.81
146.98
1.83
1.2%
` includes calculated Appliances and Miscellaneous Energy Use (AMEU)
.,
IPA
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Number of Dwelling
Number of Ventilation
Number of Water
Project Name
Conditioned Floor Area (ft2)
"Units
Number of Bedrooms
Number of Zones
Cooling Systems
Heating Systems
Monterra Plan 1
3180
r` r 1
6
2
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Living Zone
Conditioned
HVAC 11
1612
10
DHW Sys 1
Sleeping Zone
Conditionec(�
HVAC 22
1568
10
DHW Sys 1
,"A4
r
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:01:06
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1
Calculation Description: Title 24 Analysis
Calculation DatelTime: 10:00, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xm1
CF1 R-PRF-01
I r
Page 4 of 10
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door Area (ft)
Tllt (deg)
N Wall
Living Zone
R-21 Wall (W.19.2x6.16)
327
Front
598
233.531
90
E Wall
Living Zone
R-21 Wall (W.19.2x6.16)
57
Left
374
64.984
90
S Wall
Living Zone
R-21 Wall (W.19.2x6.16)
147
Back
25
90
W Wall
Living Zone
R-21 Wall (W.19.2x6.16)
237
Right
95
90
R-38 Roof
Living Zone
R-38 Roof(R.38.2x14.16)
1612
N Wall 2
Sleeping Zone
R-21 Wall (W.19.2x6.16)
c,\
�- 327
Front
187
90
E Wall 2
Sleeping Zone
R 21 Wall (W.19.2x6.16)
57
Left
155
18
90
S Wall 2
Sleeping Zone
R-21 Wall (W.19.2x6.16) r'.`
147
Back
700
228
90
W Wall 2
Sleeping Zone
R-21 Wall (W.19.2x6.16)
237
Right
440
74
90
R-38 Roof 2
Sleeping Zone
R-38 Roof(R.38.2x14. '6),
1568
ATTIC
01
02
03
704
05
06
07
08
Name
Construction
Type °
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Living Zone
Attic Roof Living Zone
Unventilated A
4.36764
0.1
0.85
Yes
No
Attic Sleeping Zone
Attic RoofSleeping Zone
Unventilated 4'�;
4.36764
0.1
0.85
Yes
No
�w
o
Registration Number: $'
CA Building Energy Efficiency Stan'da'rds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFiR-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:01:06
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 10:00, Wed, Nov 04, 2015
CF1 R-PRF-01
Page 5 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xm1
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multipll
er
Area
(ft2)
U-factor
SHGC
Exterior Shading
1.5X8 F
Window
N Wall (Front-327)
2.0
8.0
0.75
12.0
0.32
0.24
Insect Screen (default)
3.5X8 FD
Window
N Wall (Front-327)
2.5
8.0
1.4
28.0
0.32
0.24
Insect Screen (default)
1.5X8 F 2
Window
N Wall (Front-327)
2.0
8.0
0.75
12.0
0.32
0.24
Insect Screen (default)
20X8 PD
Window
N Wall (Front-327)
23.3
8.0
0.858
159.9
0.32
0.24
Insect Screen (default)
5X8 F
Window
E Wall (Left-57)
6.0
8.0
0.833
40.0
0.32
0.24
Insect Screen (default)
2.5X5 F
Window
E Wall (Left-57),,,"
----
1
12.5
0.32
0.24
Insect Screen (default)
2.5X5
Window
E Wall (Left-57)
=
1
12.5
0.32
0.24
Insect Screen (default)
3X6 F
Window
E Wall 2 (Left-57)L--
1
18.0
0.32
0.24
Insect Screen (default)
6X8 FD
Window
S Wall 2 (Back-147)
A;` ----
1
48.0
0.32
0.24
Insect Screen (default)
2X3 F
Window
S Wall 2 (Back-147) <
''` ----
---
1
6.0
0.32
0.24
Insect Screen (default)
6X6 SL
Window
S Wall 2 (Back-147)
----
----
1
36.0
0.32
0.24
Insect Screen (default)
2X3 F 2
Window
S Wall 2 (Back-147)�
----
----
1
6.0
0.32
0.24
Insect Screen (default)
6X6 SL 2
Window
S Wall 2 (Back-147) 4'
----
----
1
36.0
0.32
0.24
Insect Screen (default)
6X8 FD 2
Window
S Wall 2 (Back-147)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
6X8 FD 3
Window
S Wall 2 (Back-147)
1
48.0
0.32
0.24
Insect Screen (default)
2X5 F
Window
W Wall 2 (Right-237)`
----
1
10.0
0.32
0.24
Insect Screen (default)
5X5 F
Window
W Wall 2 (Right-', 237)
1
10.0
0.32
0.24
Insect Screen (default)
9X6 SI
Window
W Wall 2 (Right 237)
---
1
54.0
0.32
0.24
1 Insect Screen (default)
DOORS
01
02
03
04
Name
Side of Building
Area (ft)
U-factor
Door
N Wall
21.6
0.50
Registration Number: m .
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:01:06
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 10:00, Wed, Nov 04, 2015
CF1 R-PRF-01
� r
Page 6 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xml
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DIstL
Bot Up
Depth
Top Up
Dist R
Bot Up
1.5X8 F
11
0.1
11
11
0
0
0
0
0
0
0
0
0
3.5X8 FD
11
0.1
11
11
0
0
0
0
0
0
0
0
0
1.5X8 F 2
11
0.1
11
11
0
0
0
0
0
0
0
0
0
20X8 PD
14
0.1
14
14
0
0.
0
0
0
0
0
0
0
5X8 F
10
0.1
10
10
0
1 i0 �
0
0
0
0
0
I 0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
-;,
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
g
Cavity / Frame: no insul. /2x4 Top Chrd
2x4 Top Chord"Of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofLiving Zone
Attic Roofs
Wood Framed Ceiling
in O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
s=
Cavity/Frame: R-9.1 /2x4
R-38 Roof (R.38.2x14.16)
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
y
Inside Finish: Gypsum Board
Cavity / Frame: R-21 /2x6
€>
Exterior Finish: Wood
R-21 Wall (W 19.2x6.16)
Exterior Walls
Wood Framed Walf, ,
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
Cavity/Frame: no insul. /2x4 Top Chrd
<
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofSleeping Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS
01
02
03
04
05
06
07
Name
zone,
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
Living'Zone
111
27
None
1
No
Hard Surface Slab
('Living Zone
1501
61
None
0
No
Covered Slab 2
°`;Sleeping Zone
340
35
None
1
No
Hard Surface Slab 2
„';r. Sleeping Zone
y
1228
93
None
0
No
Registration Number::,
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:01:06
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 10:00, Wed, Nov 04, 2015
CF1 R-PRF-01
r r
Page 7 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xm1
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quallty Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
---
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 - 1/1
DHW
Pipe Insulation, All Lines
DHW Heater 1
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Tank Exterior
Tank 1%lume
Energy Factor or
Insulation
Standby Loss
Name
Heater Element Type
Tank Type
a-1)
ten.
Efficiency
Input Rating
R-value
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
a "`''' 50
0.62
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Recirculation
Central DHW
Name
Pipe Insulation
Piping
Compact Distribution
Point -of Use
Control
Distribution
yParallel
DHW Sys 1 - 1/1
---
---
---
---
SPACE CONDITIONING SYSTEMS >;
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC 11
Other Healing and Cooling
fir,., System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC 22
Other`Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
Registration Number:
CA Building Energy Efficiency Stand rds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFIR-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:01:06
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation DatelTime: 10:00, Wed, Nov 04, 2015
CF1 R-PRF-01
� r
Page 8 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xml
HVAC - HEATING UNIT TYPES
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 2
CntrlFurnace - Fuel -fired central furnace
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEERw
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
11.5
"?
13Mz..5
Not Zonal
Single Speed
Cooling Component
1-hers cool
Cooling Component 2
SplitAirCond
11.5Ir
13.5
Not Zonal
Single Speed
Cooling Component
.�
1-hers-cool
WU
HVAC COOLING - HERS VERIFICATION=:
01
02
3"
04
05
06
Name
Verified Airflow
Alrflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Not Required
Not Required
Not Required
Cooling Component 2-hers-cool
Required
J'' 350
Not Required
Not Required
Not Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsInAll
Sealed and tested
8
Conditioned zone
None
Air Distribution System
.
1-hers-dist
Air Distribution System 2
DuctslnAli ,,,
Sealed and tested
8
Conditioned zone
None
Air Distribution System
2 hers dist
HVAC DISTRIBUTION - HERS VERIFICATION'
01
4'02 �
03
04
05
06
07
08
Name
Ductteakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Burled
Ducts
Deeply Burled
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
y Required
6.0
Required
Not Required
Not Required
Not Required
---
Air Distribution System 2-hers-disty
Required
6.0
Required
Not Required
Not Required
Not Required
4
Registration Number: fi Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:01:06
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 10:00, Wed, Nov 04, 2015
CF1 R-PRF-01
� r
Page 9 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xml
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required '
0.58
HVAC Fan 2-hers-fan
Req .uiredf
, n
0.58
IAO (Indoor Air Quality) FANS-
01
02
03 ,, ;'9'
04
05
06
IAO Recovery
Dwelling Unit
IAO CFM
IAQ Walts/CFM
IAQ Fan TypeI
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
84.3
.25
Default
0
Required
Registration Number: r
CA Building Energy Efficiency Stah6rds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:01:06
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 10:00, Wed, Nov 04, 2015
CF1 R-PRF-01
Page 10 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xml
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc,
11/4/2015
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/5tateIaplm Desert, CA 92211
Phone: (760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for. the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate ofCompliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency`foif approval with this building permit application.
Responsible Designer Name: a
Responsible Designer Signature:
Jim Deford
Company: ,
Date Signed:
Helton, DeFord & Associates
Address:' - •
License:
17411 Irvine Blvd, Suite O
City/State2ip:
Phone:
Tustin, CA 92780
(909) 957-4550
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFiR-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:01:06
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Monterra, Plan 1-Revised
Building Type 10 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111412015
Project Address
55-101 Monroe La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,180
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features
Status
Roof Wood Framed Attic
R 38 3,180
New
Wall Wood Framed
R 21 1,955
New
Door Opaque Door
-
no insulation 22
New
Slab Unheated Slab -on -Grade
- no insulation 3,180 Perim = 216'
New
Demising Wood Framed
-
no insulation 1,360
New
FENESTRATION
Orientation Area(ft)
I Total Area: 597 Glazing Percentage: 18.8 New/Altered Average U-Factor:
U-Fac SHGC Overhang Sidefins Exterior Shades
0.32
Status
Front (NVto 52.0
0.320
0.24 11.0 none Bug Screen
New
Front (NVio 160.0
0.320
0.24 14.0 none Bug Screen
New
Left (NE) 40.0
0.320
0.24 10.0 none Bug Screen
New
Left (NE) 43.0
0.320
0.24 none none Bug Screen
New
Rear (SE) 228.0
0.320
0.24 none none Bug Screen
New
Right (SVV) 74.0
0.320
0.24 none none Bug Screen
New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace
80 % AFUE
Split Air Conditioner 13.5 SEER Setback
New
1 Central Furnace
80 % AFUE
Split Air Conditioner 13.5 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
HVAC 1 Ducted
Ducted Conditioned 8.0
New
HVAC 2 Ducted
Ducted Conditioned 8.0
New
WATER HEATING
Q . Type
Gallons Min. Eff Distribution Status
1 Small Storage Gas
50
0.62 All Pipes Ins
New
Ene Pro 6.7 b Ene Soft User Number. 6712
RunCode: 2015-11-04T10:01:41 ID:
Pa a 13 of 26
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration that meets the requirements of §10-111(a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal enuttance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CF1R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U-factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ 150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R-value.
§ 150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U-
factor).
§ 150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U-factor.
In Climate Zones 14 and 16 a Class 11 vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§ 150.0(g)l:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class 11 vapor retarder shall be placed over the earth floor of
§150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § I10.8(g).
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U-factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)1A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)1B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§150.0(e)1C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§ 150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in 150.0 h 2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§ 150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.00)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
a013 Low -Rise Residential Mandatory Measures Summary
§ 150.00)2C:
Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ 150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSFSMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross -sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ 150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R-value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ 150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§ 150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ 150.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§ 150.0(m)13:
space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy < 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ 150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of > 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§ 150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous bunting pilot light.
§ 150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§ 150.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § I50.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-13, as applicable.
§ 150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single lununaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)1C:
§130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting per electrical box.
§ 150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§ 150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ I50.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ 150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9. meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in § 150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of §130.5; and all other requirements in § 150.0(k)2.
§ 150.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to §110.9, and complies with all other applicable requirements in §150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ 150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ 150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing fimction and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronornical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§150.0(k)9B:
following requirements:
i. Shall comply with § 150.0(k)9A; or
ii. Shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, § 130.0, § 130.2. § 130.4, § 140.7 and § 141.0.
§ 150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ 150.0(k)l l:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9, § 130.0, § 130.1, § 130.4, § 140.6, and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10(b) through § 110.10(e).
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§110.10(b)l:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Monterra, Plan 1-Revised
Date
11/4/2015
System Name
HVAC 1
Floor Area
1,612
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 861
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
17,724
2,475
349
15,476
Total Output (Btuh)
89,000
0
Output (Btuh/sgft)
55.2
257
184
Cooling System
01
0
Output per System
57,800
0
0
0
0
Total Output (Btuh)
57,800
0
2,475
0
Total Output (Tons)
4.8
257
184
Total Output (Btuh/sgft)
35.9
Total Output (sgft/Ton)
334.7
1 18,237
15,844
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow (cfm)
2,000
Carrier 24ACA460/58CVX110
41,690
4,339
89,000
Airflow (cfm/sgft)
1,24
Airflow (cfm/Ton)
415.2
Outside Air (%)
0.0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
41,690
4,339
89,000
Jan 1 AM
Outside Air (cfm/sgft)
0.00
I
Note: values above given at ARI conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS (Airstream
Temperatures at Time of Heating Peak)
26 OF 72 OF
Outside Air
0 cfm Supply Fan
2,000 cfm
72 OF
72 OF 114 OF
Heating Coil
Ll Lu
114 OF
p
ROOM ��
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112 / 78 OF 70 l 58 OF 70158 OF 51 / 50 OF
Outside Air
0 cfm Ar Supply Fan 2,000 cfm Cooling Coil
70 ! 58 OF
51 / 50 OF
48.3 % RO--- OM --- {
70 / 58 OF
EnergYPro 6.7 by EnergySoR User Number. 6712 RunCode: 2015-11-04T10:01.41
/D. Page 18 of 26
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Monterra, Plan 1-Revised
Date
11/4/2015
System Name
HVAC 2
Floor Area
1,568
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 872
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
17,982
2,407
406
17,977
Total Output (Btuh)
89,000
0
Output (Btuhlsgft)
56.8
260
214
Cooling System
0
0
Output per System
57,800
0
0
0
0
Total Output (Btuh)
57,800
0
2,407
0
Total Output (Tons)
4•8
260
214
Total Output (Btuh/sgft)
36.9
Total Output (sgft/Ton)
325.5
1 18,503
18,405
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow (cfm)
2,000
Carrier 24ACA460/58CVX110
41,745
4,267
89,000
Airflow (cfm/sgft)
1.28
Airflow (cfm/Ton)
415.2
Outside Air (%)
0.0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
41,745
4,267
89,000
Jan 1 AM
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS (Airstream
Temperatures at Time of Heating Peak)
26 OF 72 OF
Outside Air-
0 cfm Supply Fan
2,000 cfm
72 OF
72 OF 114 OF
Heating Coil
114 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112 / 78 OF 70158 OF 70 / 58 OF 51 / 50 OF
Outside Air '
0 cfm Supply Fan Cooling Coil
2,000 cfm
70 ! 58 OF
51 / 50 OF
r
48.2 % ROOM
70 / 58 OF
EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-11-04T10:01:41
ID: Page 19 of 26
ROOM LOAD SUMMARY
Project Name Date
Monten-a, Plan 1-Revised 111412015
System Name Floor Area
HVAC 1 1,612
ROOM LOAD SUMMARY
ROOM COOLING PEAK I COIL COOLING PEAK COIL HTG. PEAK
Zone Name I Room Name I Mult. I CFM Sensible I Latent I CFM I Sensible I Latent CFM I Sensible
Living Zone I Living 1 1 1 8611 17,7241 2,4751 8611 17,7241 2,475 3491 15,476
PAGE TOTAL
TOTAL*
861
17,7241
Z 475
349
15,476
861
17,724
2,475
349
15,476
* Total includes ventilation load for zonal systems.
EnergyPto 6.7 by EnergySoft User Number: 6712 RunCode: 2015-11-04T10:01.41 ID: Page 20 of 26
ROOM LOAD SUMMARY
Project Name Date
Monten-a, Plan 1-Revised 111412015
System Name Floor Area
HVAC 2 1,568
ROOM LOAD SUMMARY
ROOM COOLING PEAK I COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Sleeping Zone Sleeping 1 872 17,982 Z407 872 17,982 Z407 406 17,977
PAGE TOTAL
TOTAL*
872
17,9821
Z 407
406
17,977
872
17,9821
Z 407
406
17,977
* Total includes ventilation load for zonal systems
EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-11-04T10:01:41 ID: Page 21 of 26
ROOM HEATING PEAK LOADS
Project Name
Monterra, Plan 1-Revised
Date
111412015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Living
Floor Area 1,612.0 ft2
Indoor Dry Bulb Temperature 72 °F
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
=
c
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof(R.38.2x 14.16)
1,612.0
0.0260
46
1,928
R-21 Wall (W.19.2x6.16)
793.4
0.0690
46
2,518
Milgard Low-E Vinyl
277.0
0.3200
46
4,077
Wood Door
21.6
0.5000
46
497
Slab -On -Grade
perim = 88.0
0.7300
46
2,955
*R-0 Wall
680.0
0.3560
0
0
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 1,612 X
Area
another room
10.00 X 0.266
Height ACH
Page Total
/ 60 J X
AT
11,975
=F7 3,501
TOTAL HOURLY HEAT LOSS FOR ROOM 15,476
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-11-04T10:01.41 ID: Page 22 of 26
ROOM HEATING PEAK LOADS
Project Name
Monterra, Plan 1-Revised
Date
111412015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Sleeping
Floor Area 1,568.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F
=
=
c
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof(R.38.2x14.16)
1,568.0
0.0260
46
1,875
R-21 Wall (W.19.2x6.16)
1,162.0
0.0690
46
3,688
Milgard Low-E Vinyl
320.0
0.3200
46
4,710
Slab -On -Grade
perim = 128.0
0.7300
46
4,298
*R-0 Wall
680.0
0.3560
0
0
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 1,568 X
Area
another room
10.00 X 0.266
Height ACH
Page Total
/ 60 ] X
AT
14,572
= 3,405
TOTAL HOURLY HEAT LOSS FOR ROOM 17,977
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-11-04T10:01.41 ID: Page 23 of 26
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Monterra, Plan 1-Revised
111412015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Living
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,612.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
R-38 Roof(R. 38.2x 14.16)
(SM 1, 612.0 X 0.0260
X 56.0 =
2,347
R-21 Wall (W.19.2x6.16)
(NIAq 364.4 X 0.0690
X 29.5 =
742
Wood Door
(NVIO 21.6 X 0.5000
X 29.5 =
319
R-21 Wall (W.19.2x6.16)
(NE) 309.0 X 0.0690
X 30.1 =
641
R-21 Wall (W.19.2x6.16)
(SE) 25.0 X 0.0690
X 29.7 =
51
R-21 Wall (W.19.2x6.16)
(SW) 95.0 X 0.0690
X 31.5 =
207
*R-0 Wall
680.0 X 0.3560
X 0.0 =
0
X
X =
X
X =
Page Total
4,306
Items shown with an asterisk (*)
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area GLF
Btu/hr
1.5X8 F
(NM 0.0 X 15.3 +
12.0 X 23.0 =
276
3.5X8 FD
(NIM 0.0 X 15.3 +
28.0 X 23.0 =
645
1.5X8 F
(NIAq 0.0 X 15.3 +
12.0 X 23.0 =
276
20X8 PD
(NIAq 0.0 X 15.3 +
160.0 X 23.0 =
3,684
5X8 F
(NE) 10.2 X 15.3 +
29.8 X 24.8 =
894
2.5X5 F
(NE) 0.0 X 15.3 +
12.5 X 24.8 =
310
2.5X5
(NE) 0.0 X 15.3 +
12.5 X 24.8 =
310
X +
X =
X +
X =
Page Total
6,395
Internal Gain
Btulhr
Occupants
4 8 Occupants X 245
Btuh/occ. =
1,185
Equipment
1,612 Floor Area X 0.50
W/sgft =
2,751
Infiltration: 1.064
X 0.94 X 73.88 X 42 =
3,088
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
17,724
Latent Gain
Btulhr
Occupants
4 8 Occupants X 155
Btuh/occ. =
750
Infiltration: 4,771
X 0.94 X 73.88 X 0.00523 =
1,725
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
750
EnemyPro 6.7 by EnergySoft
User Number. 6712 RunCode: 2015-11-04T10:01:41 ID:
Pa - a 24 of 26
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Monterra, Plan 1-Revised 111412015
ROOM INFORMATION DESIGN CONDITIONS
Room Name Sleeping Outdoor Dry Bulb Temperature 112 OF
Floor Area 1,568.0 ftz Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF
Opaque Surfaces
R-38 Roof(R.38.2x 14.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
•R-0 Wall
Orientation
(SVO
(NW)
(NE)
(SE)
(SW)
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
Btu/hr
1,568.0
0.0260
56.0
2, 283
187.0
0.0690
29.5
381
137.0
0.0690
30.1
284
472.0
0.0690
29.7
966
366.0
0.0690
31.5
796
680.0
0.3560
0.0
0
Page Total
4, 710
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
3X6 F
6X8 FD
2X3 F
6X6 SL
2X3 F
6X6 SL
6X8 FD
6X8 FD
2X5 F
Orientation
(NE)
(SE)
(SE)
(SE)
(SE)
(SE)
(SE)
(SE)
(SIM
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
-
0.0
15.3
18.0
24.8
0.0
15.3
48.0
19.4
0.0
15.3
6.0
19.4
0.0
15.3
36.0
19.4
0.0
15.3
6.0
19.4
0.0
15.3
36.0
19.4
0.0
15.3
48.0
19.4
0.0
15.3
48.0
19.4
0.0
15.3
10.0
21.3
Page Total
Btu/hr
446
930
116
697
116
697
930
930
213
5, 076
Internal Gain Btu/hr
Occupants 4 7 Occupants X 245 Btuh/occ. = 1,152
Equipment 1,568 Floor Area X 0.50 w/sgft = Z676
Infiltration: 1.064 X 0.94 X 71.86 X 42 =
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,9821
Latent Gain Btu/hr
Occupants 4 7 Occupants X 155 Btuh/occ. = 729
Infiltration: 4,771 X 0.94 X 71.86 X 0.00523 = 11678
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 7291
99
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Monterra, Plan 1-Revised
1 111412015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Sleeping
Outdoor Dry Bulb Temperature
112 OF
Floor Area 1,568.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 0FJ
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U-Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (*) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area
GLF
Btu/hr
5X5 F (SlM 0.0 X 15.3 +
10.0
X 21.3
= 213
9X6 SI (SVIO 0.0 X 15.3 +
54.0
X 21.3
= 1,151
X +
X
=
X +
X
—
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +
X
—
Page Total
1,364
Internal Gain
Btu/hr
Occupants 4 7 Occupants X 245
Btuh/occ.
=
1,152
Equipment 1,568 Floor Area X 0.50
w/sgft
=
2,676
Infiltration: 1.064 X 0.94 X 71.86 X 42 =
3,004
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
17,982
Latent Gain
Btu/hr
Occupants 4.7 Occupants X 155
Btuh/occ.
=
729
Infiltration: 4,771 X 0.94 X 71.86 X 0.00523 =
1,678
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
729
EnerqyPro 6.7 by EnerqySoft User Number- 6712 RunCode: 2015-11-04T10:01:41 ID:
Pa a 26 of 26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation DatelTime: 10:00, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xml
CF1 R-PRF-01
Page 1 of 10
GENERAL INFORMATION
01
Project Name
Monterra Plan 1
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2015
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2013-4 (744)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.6
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
3180
15
Number of Zones
2
16
Slab Area (ft2)
3180
17
Number of Stories
1
18
Addition Cond. Floor Area
N/A
19
Natural Gas Available
Yes
r2O
Addition Slab Area (ft2)
N/A
21
Glazing Percentage (%)
18.8%
COMPLIANCE RESULTS ;z-
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by;a certified HERS rater under the supervision of a'CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
Cl 1 >I OF LA QIJINTA
BUIL®ING & SAF�DEPT.
�R PP�ED
FOR CONSRUCTlON
DATE (2. U4L-S
Registration Number: 214-N0163383C-000000000-0000 Registration Date/Time: 2015-11-04 10:09:29 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08252015-744 Report Generated at: 2015-11-04 10:01:13
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation DatelTime: 10:00, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xml
CF1 R-PRF-01
Page 2 of 10
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.11
0.80
0.31
27.9%
Space Cooling
97.32
89.68
7.64
7.9%
IAQ Ventilation
1.18
1.18
0.00
0.0%
Water Heating
8.07
7.61
0.46
5.7%
PV Credit
----
0.00
0.00
----
North Facing Compliance Total
107.68
99.27
8.41
7.8%
Space Heating
1.11
1.39
-0.28
-25.2%
Space Cooling
97.32
95.67
1.65
1.7%
IAQ Ventilation
1.18
1.18
0.00
0.0%
Water Heating
8.07
7.61
0.46
5.7%
PV Credit
----
0.00
0.00
----
East Facing Compliance Total
107.68
105.85
1.83
1.7%
Space Heating
1.11
1.77
-0.66
-59.5%
Space Cooling
97.32,:
86.71
10.61
10.9%
IAQ Ventilation
1.18
1i18
0.00
0.0%
Water Heating
8.07
7.61
0.46
5.7%
PV Credit
=--
0.00
0.00
----
South Facing Compliance Total
107.68
97.27
10.41
9.7%
Space Heating
1.11
1.20
-0.09
-8.1%
Space Cooling
97.32
92.54
4.78
4.9%
IAQ Ventilation
1.18
1.18
0.00
0.0%
Water Heating
8.07
7.61
0.46
5.7%
PV Credit
----
0.00
0.00
----
West Facing Compliance Total
107.68
102.53
5.15
4.8%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins ��
• Exposed slab floor In conditioned zone ]'
[� SJ
Fps C P'�
DATE OnjST7-1
Registration Number: 214-N0163383C 000000000-0000 Registration Date/Time: 2015-11-04 10:09:29 , ov`i=:gync.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report ' rnera d
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
` Project Name: Monterra Plan 1 Calculation Date/Time: 10:00, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xm1
HERS FEATURE SUMMARY
CF1 R-PRF-01
Page 3 of 10
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAO mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Ducts located entirely In conditioned space
Domestic Hot Water System Verifications:
• -- None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on -site renewable energy system.
Reference Energy Use
Energy Design Rating
Margin
Percent Improvement
Total Energy (kTDV/f2-yr)•
148.81
146.98
1.83
1.2%
' includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Monterra Plan 1
3180
1
6
2
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Living Zone
Conditioned
HVAC 11
1612
10
DH
Sleeping Zone
Conditioned
HVAC 22
1568
10
1DIWS,. s
I0U►LDI(�iG - • "kJI"V I
li DEP7
AAPpRoFoj� C��'s r>�/ED
DATE
Registration Number: 214-N0163383C-000000000-0000 Registration Date/Time: 2015-11-04 10:09:29 �' F4F•!3$ Pro 13Y CaICER S inc.
3
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08252015-744 Report Generated at: K-�1-�a 0 03:,
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
r
Project Name: Monterra Plan 1 Calculation Date/Tlme: 10:00, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xml
CF1 R-PRF-01
Page 4 of 10
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door Area (ft)
Tilt (deg)
N Wall
Living Zone
R-21 Wall (W 19.2x6.16)
327
Front
598
233.531
90
E Wall
Living Zone
R-21 Wall (W.19.2x6.16)
57
Left
374
64.984
90
S Wall
Living Zone
R-21 Wall (W.19.2x6.16)
147
Back
25
90
W Wall
Living Zone
R-21 Wall (W.19.2x6.16)
237
Right
95
90
R-38 Roof
Living Zone
R-38 Roof(R.38.2x14.16)
1612
N Wall 2
Sleeping Zone
R-21 Wall (W. 1 9.2x6.16)
327
Front
187
90
E Wall 2
Sleeping Zone
R-21 Wall (W 19.2x6.16)
57
Left
155
18
90
S Wall 2
Sleeping Zone
R-21 Wall (W. 1 9.2x6.16)
147
Back
700
228
90
W Wall 2
Sleeping Zone
R-21 Wall (W 19.2x6.16)
237
Right
440
74
90
R-38 Roof 2
Sleeping Zone
R-38 Roof(R.38.2x14.16)
1568
ATTIC
01
02
`'03 �
� 04
05 r '.
06
07
08
Name
Construction
Type
Roof Rlse
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Living Zone
Attic RoofLiving Zone
Unventilated <.
4.36764
0.,1
0.85
Yes
No
Attic Sleeping Zone
Attic RoofSleeping Zone
Unventilated '
4.36764
0.1
0.85
Yes
No
BUILDINGc �.il► �-,�
APPFioVEDTI
FOR CONSTRUCTION
DATE
BY
Registration Number: 214-N0163383C-000000000-0000 Registration Date/Time: 2015-11-04 10:09:29 HERS Provider: aIRTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 10:01:13
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 10:00, Wed, Nov 04, 2015
CF1 R-PRF-01
Page 5 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xml
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multlpli
er
Area
(ft)
U-factor
SHGC
Exterior Shading
1.5X8 F
Window
N Wall (Front-327)
2.0
8.0
0.75
12.0
0.32
0.24
Insect Screen (default)
3.5X8 FD
Window
N Wall (Front-327)
2.5
8.0
1.4
28.0
0.32
0.24
Insect Screen (default)
1.5X8 F 2
Window
N Wall (Front-327)
2.0
8.0
0.75
12.0
0.32
0.24
Insect Screen (default)
20X8 PD
Window
N Wall (Front-327)
23.3
8.0
0.858
159.9
0.32
0.24
Insect Screen (default)
5X8 F
Window
E Wall (Left-57)
6.0
8.0
0.833
40.0
0.32
0.24
Insect Screen (default)
2.5X5 F
Window
E Wall (Left-57)
----
----
1
12.5
0.32
0.24
Insect Screen (default)
2.5X5
Window
E Wall (Left-57)
----
----
1
12.5
0.32
0.24
Insect Screen (default)
3X6 F
Window
E Wall 2 (Left-57)
----
----
1
18.0
0.32
0.24
Insect Screen (default)
6X8 FD
Window
S Wall 2 (Back-147)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
2X3 F
Window
S Wall 2 (Back-147)
----
----
1
6.0
0.32
0.24
Insect Screen (default)
6X6 SL
Window
S Wall 2 (Back-147)
----
----
1
36.0
0.32
0.24
Insect Screen (default)
2X3 F 2
Window
S Wall 2 (Back-147)
--- _
1
6.0
0.32
0.24
Insect Screen (default)
6X6 SL 2
Window
S Wall 2 (Back447)
--
---
1
36.0
0.32
0.24
Insect Screen (default)
6X8 FD 2
Window
S Wall 2 (Back-147)
--
- --
1
48:0
0.32
0.24
Insect Screen (default)
6X8 FD 3
Window
S Wall 2 (Back-147)..'
----
--
1
48.0
0.32
0.24
Insect Screen (default)
2X5 F
Window
W Wall 2 (Right-237)
----
1
10.0
0.32
0.24
Insect Screen (default)
5X5 F
Window
W Wall 2 (Right-237)
----
1
10.0
0.32
0.24
Insect Screen (default)
9X6 SI
Window
W Wail 2 (Right-237)
---
---
1
54.0
0.32
0.24
Insect Screen (default)
DOORS
01
02
03
04
Name
Side of Building
Area (ft)
U-factor
Door
N Wall
21 _6__
0.50
UTY OFLAQU IN
BUILDING & SAP
APPROV Y ®EPr.
FOR CONSTRUC�D
ON
DATE
Registration Number: 214-N0163383C-000000000-0000 Registration Date/Time: 2015-11-0410:09:29
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:01:13
inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 10:00, Wed, Nov 04, 2015
CF1 R-PRF-01
Page 6 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xmi
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DIstL
Bot Up
Depth
Top Up
Dist R
Bot Up
1.5X8 F
11
0.1
11
11
0
0
0
0
0
0
0
0
0
3.5X8 FD
11
0.1
11
11
0
0
0
0
0
0
0
0
0
1.5X8 F 2
11
0.1
11
11
0
0
0
0
0
0
0
0
0
20X8 PD
EA,
14
0.1
14
14
0
0
0
0
0
0
0
0
0
5X8 F
10
0.1
10
10
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
, ,
Roof Deck: Wood Siding/sheathing/decking
Attic RoofLiving Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof(R.38.2xl 4.16)
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R-21 /2x6
• Exterior Finish: Wood
R-21 Wall (W. 1 9.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofSieeping Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. "ue & De th
Carpeted Fraction
Heated
Covered Slab
Living Zone
111
27
111 one`
- f I i
N
Hard Surface Slab
Living Zone
1501
61
on i i I I.
�� N
N.
Covered Slab 2
Sleeping Zone
340
35
one E:) M
`J i r
L NCO
Hard Surface Slab 2
Sleeping Zone
1228
93
one
n Rn 0
0
Registration Number: 214-N0163383C-000000000-0000 Registration Date/Time: 2015-11-0410:09:29
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08252015-744
.E
v. _ HltS-Prtsvider�Y CaIC RTS inc.
Report Generated at: 2015-11-0�1:13
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 10:00, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xml
CF1 R-PRF-01
Page 7 of 10
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
---
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 - 1/1
DHW
Pipe Insulation, All Lines
DHW Heater 1
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.62
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02s'n
03
04
05
06
07
Recirculation
Central DHW
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Control
Distribution
DHW Sys 1 - 1/1
---
---
---
SPACE CONDITIONING SYSTEMS
01
02
03
04 05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name Fan Name
Distribution Name
HVAC 11
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1 HVAC Fan 1
Air Distribution System 1
HVAC 22
Other Heating and Cooling
Heating Component 2
Cooling Component 2IF r, t C a �:
iN
ir-Disbibutiori-Systern 2
r — I
BUILDING & SAF-K %a IETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE
Registration Number: 214-N0163383C-000000000-0000 Registration Date/Time: 2015-11-04 10:09:29
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08252015-744
Report Generated at: 2015-11-04 10:01:13
inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 10:00, Wed, Nov 04, 2015
CF1 R-PRF-01
Page 8 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xm1
HVAC - HEATING UNIT TYPES
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 2
CntrlFurnace - Fuel -fired central furnace
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
11.5
13.5
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Cooling Component 2
SplitAirCond
11.5
13.5
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03,->
04
05
06
Name
Verifie& Irflovi ,
Airflow Target
RVerifled EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
_ 350 „4
Not Required
Not Required
Not Required
Cooling Component 2-hers-cool
Required -
350
Not Required
Not Required
Not Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctslnAll
Sealed and tested
8
Conditioned zone
None
Air Distribution System
1-hers-dist
Air Distribution System 2
DuctslnAll
Sealed and tested
8
Conditioned zone
None
Air Distribution System
2-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION r
01
02
03
04
05
06
I N �PA I
Rt-
a ^07
Duct Leakage
Duct Leakage
Verified Duct
Verified Duct
Burl
ply BuTI'ede
r�/ jCtwvletakag
Name
Verification
Target(%)
Location
Design
Duct J`Mpu
__ _ cts��i
Handle
Air Distribution System 1-hers-dist
Required
6.0
Required
Not Required
Not Req ired
v o'W4 u red3UJ
,-T10
Air Distribution System 2-hers-dist
Required
6.0
Required
Not Required
Not Regiui e
Not Required
_
--- _�By
Registration Number: 214-N0163383C-000000000-0000 Registration Date/Time: 2015-11-04 10:09:29 'S-p_lGk"er: RTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 10:01:13
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 10:00, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xmi
CF1 R-PRF-01
Page 9 of 10
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
HVAC Fan 2-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
84.3
0.25
Default
0
Required
Registration Number: 214-N0163383C-000000000-0000 Registration Date/Time: 2015-11-04 10:09:29
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
B JIiY OF L 1 QUINTq
LDING & SAFETY DEPT
APPROVED
CONSTRUCTION
DATE__ BY
HER roGider:------GaICEaU
Report Generated at: 2015-11-04 10:01:13
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation DatelTlme: 10:00, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xml
CF1 R-PRF-01
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Terri-�ce`i
Company:
Signature Date:
Scott Design and Title 24, Inc.
2015-11-04 10:09:29
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State2ip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency. for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Tim Scott
Company:
Date Signed:
Scott Design and Title 24, Inc.
2015-11-04 10:09:29
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
information.
CITY OF LA QUINTA
9r��/"1p�c�r "'' ty &r rbcnacEUr',�U OL9i1PT.
APPROVED
FOR CONSTRUCTION
Registration Number: 214-N0163383C-000000000-0000 Registration Date/Time: 2015-11-0410:09:29
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
Report Generated at:
t BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Monterra, Plan 1-Revised
55-101 Monroe
La Quinta, CA 92253
Project Designer:
Helton, DeFord & Associates
17411 Irvine Blvd, Suite 0
Tustin, CA 92780
(909) 957-4550
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
77085 Michigan Drive
Palm Desert, CA 92211
(760) 200-4780
CITY OF LA QUINTA
BUILDING & SAFETY
APPROVED
FOR CONS RUCTION
Job Numbe :DATE 9I1 1lc
Date:
3/19/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
I r TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form MF-1 R Mandatory Measures Summary 3
HVAC System Heating and Cooling Loads Summary 7
Room Load Summary 9
Room Heating Peak Loads 11
Room Cooling Peak Loads 13
CITY OF LA UINT
-
BUILDING & SAFETY DEPAT
APPROVED
FOR CONSTRUCTION
I DATE ---.BY
EnergyPro 6.5 by EnergySoft Job Number. ID: User Number: 6712
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
cmmnliance annroach used Excentions man apply. Review the respective code section for more information
Building Envelope Measures:
§ 110.6(a)l:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain
§ 110.6(a)5:
Coefficient SHGC , and infiltration that meets the requirements of § 10-111 a .
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CF 1R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U-factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ 150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R-value.
§ 150.0(c):
Mmmmum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U-
factor).
§ 150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U-factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§ 150.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ 150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 1 10.8.
§ 150.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U-factor of all fenestration shall not exceed 0.58..
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)1A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least sic square inches in area and is
equipped with a readily accessible, operable, and tight -fitting er or a combustion -air control device.
§ 150.0(e)1C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:.
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
acces without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
and spa heaters.
§ 150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in 150. 2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback re emen o
§ 150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the a spa b�� ge�n�lly ed
v V /y
with insulation havingan installed thermal resistance of R-12 or ater
§ 150.0G)lB:
Unfired hot water tanks, such as storage tanks and backup storage tanks for so - a { ext
insulation or R-16 internal insulation where the internal insulation R-value is in
For domestic hot water system piping, whether buried or unburied: the rst 5 f om the orage
tank, all piping with a nominal diameter of 3/4 inch or larger, all pipin associat w a irculati n system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to stor a tank or between tanks, piping buried below de, and
all hot water pipes from the heating source to kitchen fixtures must be' rem according tthEjequirements of TAB 120.3-
A
§ 150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non-crusha a casmg or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§ 150.00)2C:
Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating
systems or hot water systems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ 150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ 150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/o inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross -sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ 150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R-value rahn s; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ 150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§ 150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ 150.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
150.0 m 12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§ 150.0(m)13:
space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy 5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ 150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered e ' , o ominal cooling
'c
4toed
capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 Wa �toaIi o
testing, in accordance with Reference Residential Appendix RA3. (J f v t
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Nei � ' on of
§ 150.0(o):
central forced air system air handlers used in central fan integrated ventil on systee pro g 7e
Whole Building Ventilation.
§ 150.0(o)lA:
Whole Building Ventilation airflow shall be confirmed through field v 'cation an to ce wi
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures: I DATE BY
Any pool or spa heating system shall be certified to have: a thermal efficiency that comp e c
§ 110.4(a):
Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)l:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ 150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9.
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE
§ 150.0(k)lA:
150.0-A or TABLE 150.0-B, as applicable.
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
§ 150.0(k)1B:
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)1 C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a h,minaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§ 150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k) lE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§ 150.0(k)1F:.
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ 150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if it fimctions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requizernents in 150.0 2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it
§ 150.0(k)2H:
fimctions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0 2.
§ 150.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0 2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy h minaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ 150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ 150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testingtrating laboratory; have a label that es 1 e i�s^a�u,h_ wt au less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be al g r64 e housing
IT
§150.0(k)8:
We
and ceiling, and shall have all air leak paths between conditionedc�,s a(edet or c ; and
6c Ht6 EPT.
allow ballast maintenance and replacement without requiring cutting oles�e
For recessed compact fluorescent luminaries with ballasts to qualify high a �0.0(k), a ballasts
te
shall be certified to the Energy Commission to comply with theapplikable relmopAir"
For single-family residential buildings, outdoor lighting permanently nounteil to k1rds-iNfiffid bMftboil ' gs on the
same lot shall be high efficacy, or may be low efficacy if it meets all f the following requirements:
i. Controlled by a manual ON and OFF switch that does not override oBWlie automatic acts of Items ii or iii be w; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass emotion s d by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing fimction and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
a Energy management control system which meets all of the following requirements: At a minimum provides the finctionality of
an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF 4MIjag da li lit hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ 150.0(k)9B:
following requirements:
i. Shall comply with § 150.0(k)9A; or
ii. Shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ 150.0(k)l l:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9, § 130.0, § 130.1, § 130.4, § 140.6, and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ 150.0(k)12B:
i. Comply with the applicable requirements in § 110.9, § 130.0, § 130.1, § 140.6 and § 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10 through 1 10.10e .
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b) l :
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
s
§ 110.10(d):
A copy of the construction documents or a comparable document indicatin
information from 6 110.10 through § 110.10(c)
shall be provided to the occupant
§ 110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 2
The main electrical service panel shall have a reserved space to allow for the
fo
r a
§110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at
he oppo eder to
'on or
main circuit location, and permanentlymarked as "For Future Solar Ele
�°
I vn vvIVJ I nuu I IVIV
DATE BY
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Monterra, Plan 1-Revised
3/19/2015
System Name
Floor Area
HVAC 1
1,612
ENGINEERING CHECKS,
SYSTEM LOAD
Number of Systems
1
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
805
0
COOLING PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
16,681
2,576
368
16,319
Total Output Btuh
89,000
0
Output Btuh/ ft
55.2
241
194
Cooling System
0
0
Output per System
57,800
0
0
0
0
Total Output (Btuh)
57,800
0
241
1 17,164 2,576
0
Total Output(Tons)
4.8
194
Total Output (Btuh/s ft)
35.9
Total Output ft/Ton
334.7
16,708
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 24ACA460/58CVX110
41,935
3,959
89,000
Airflow cfm/s ft)
1.24
Airflow cfmrron)
415.2
Outside Air %)
0•0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
41,935 3,959
Aug 3 PM
89,000
Jan 1 AM
Outside Air (cfm/s ft)
0.00
Note: values above given at A91 conditions
HEATING SYSTEM PSYCHROMETRICS'(A,irstrearn
Tem edtures at Time of Heating Peak)
26 OF 72 OF
72 OF 113 OF
Outside Air
0 dm Supply Fan
Heating Coil
113 °F
AL 2,000 cfm
M
ROOM
72 OF
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures eratures at Time -of Cooling Peak) .
112 / 78 °F 70 / 58 OF 70 158 OF 51 / 50 OF
Outside
OAir cfm
Supply Fan
Cooling Coil
BUILDING & SA
1 V 181 Y OF
ETY-DEP1.
2,000dm
ARYAR
WON
FOR CONST
70 / 58 OF
LA
70/ OF
DATE BY
EnergyPro 6.5 by EnewSolf User Number. 6712 RunCode: 2015-03-19T17.14.48. ID:
Page 7 of 15
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Monterra, Plan 1-Revised
3/19/2015
System Name
Floor Area
HVAC 2
1,568
ENGINEERING CHECKS
SYSTEM LOAD
Number of System;
1
COIL
CFM
Total Room Loads 825
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
17,117
2,506
398
17,622
Total Output (Stuh)
89,000
0
Output Btuhl ft
56.8
248
210
Cooling System
o
0
Output per System
57,800
0
0
0
0
Total Output Btuh)
57,800
0
248
1 17,612 2,506
0
Total Output(Tons)
4.8
210
Total Output Btuh/ ft
36.9
Total Output s ftlron
325.5
18,042
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION,
Airflow cfm
2,000
Carrier 24ACA460/58CVX110
41,991
3,886
89,000
89,000
Jan 1 AM
Airflow (cfm/s ft)
1.28
Airflow (cfm/Ton)
415.2
Outside Air %)
0•0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
41,991
3,886
Outside Air (cfm/s ft)
0.00
Note: values above given at ARI conditions .
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS
(AirStroarnTemperattires,at Time of Heating
Peak
26 OF 72 OF
72 OF 113 OF
_.. _
Outside Air
0 cfm Supply Fan
Heating Coil
113 °F
2,000 cfm
ROOM I
72 OF
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Tem rature$ at Time of Cooling Peak
112 / 78 OF 70 / 58 OF 70158 OF 51 / 49 OF
Outside AirAr
/� Q U I
U 1 Y4 LA
0 cfm
Supply Fan Cooling Coil
2,000cfm
L� /`1 �f 1 °
BUILDING & AFETY DEPW
APP
FOR CONS
70 ! 58 OF
/58°
DATE BY
Ene►gyPro 6.5 by Ene►gySoif User Number. 6712 RunCode: 2015-03-19T17.14.48
1D. Page 8 of 15
ROOM LOAD SUMMARY
Date
Montefra, Plan 1-Revised 311912015
System Name Floor Area
HVAC 1 1,612
ROOM LOAD SUMMARY`
Zone Name
Living Zone
I ' Total
Room Name Mult.
Living 1
ROOM COOLING PEAK
CFM I Sensible I Latent
8051 16,6811 Z576
PAGE TOTAL
TOTAL•
COIL COOLING PEAK
CFM I Sensible Latent
8051 16,681 Z 576
COIL HTG. PEAK
CFM I Sensible
3681 16,319
805
16,681
Z576
368
16,319
ATI805
16,681
Y 2,576
368
1 16,319
9of15
'•• • 1M�"
ProjectDate
Plan I -Revised
311912015
Name
FloorSystem :.
ROOM LOAD SUMMARY
ROOM COOLING PEAK
Sleeping Zone
_-_WQRTWF
rA�lS
MAV■
ROOM HEATING PEAK LOADS
Project Name
Monterra, Plan 1-Revised
Date
311912015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Floor Area.
Indoor Dry Bulb Temperature
Living
1,612.0 ft2
72 TF
Time of Peak
Outdoor Dry Bulb Temperature
Jan 1 AM
26 OF
Conduction Area U-Value AT °F
R-38 Roof(R.38.204.16) 1,612.0 X 0.0260 X 46 =
R-21 Wall (W 19.2x6.16) 746.0 X 0.0690 X 46 =
Milgard Low-E Vinyl 322.0 X 0.3200 X 46 _
Wood Door 24.0 X 0.5000 X 46 =
Slab -Or -Grade Perim = 88.0 X 0.7300 X 46 =
'R-0 Wall 680.0 X 0.3560 X 0 =
X X =
X X
X X
X X =
X X =
X X =
X X =
X X =
X X
X X
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X
X X =
X X =
X X =
X X
X X
X X =
Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total
Infiltration:[ 1.00 X 1.072 X 1,612 X 11.40 X 0.250 / 60 ] X 46
Schedule Air Sensible Area Ceiling Height ACH AT
Fraction
Btu/hr
1,928
Z368
4,740
552
Z955
0
12,543
= 3,777
TOTAL HOURLY HEAT LOSS FOR ROOM
16,319
EnergyPro 6.5 by EnergySoft User Number. 6 12
RunCode: 2015-03-19T17.14.48 ID..
Page 11 of 15
ROOM HEATING PEAK LOADS
Project Name
Date
Monterra, Plan 1-Revised
311912015
ROOM INFORMATION
DESIGN CONDITIONS '
Room Name
Sleeping
Time of Peak
Jan 1 AM
Floor Area
1,568.01i2
Outdoor Dry Bulb Temperature
26 OF
Indoor Dry Bulb Temperature
72 T
Conduction
Area U-Value AT °F
Btu/hr
R-38 Roof(R.38.204.16)
1,568.0 X
0.0260 X 46
=
1,875
R-21 Wall (W.19.2x6.16)
1,216.0 X
0.0690 X 46
=
3,860
Milga►d Low-E Vny/
266.0 X
0.3200 X 46
_
3,916
Slab -On -Grade
perim = 128.0 X
0.7300 X 46
=
4,298
*R-0 Wall
680.0 X
0.3560 X 0
_
0
X
X
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
X
X
=
X
X
=
X
X
=
X
X
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
X
X
=
X
X
X
X
X
X
X
Items shown with an asterisk (*) denote conduction through an interior surface to another ro
�
C I I i/ OF LA9Q
W
13,949
Infiltration:[ 1.00 X 1.072 X 1,568 X 10.00X
IINGAFE
02 _ S
P
3,674
Schedule Air Sensible
Area CeilingHeight
g
ACN
Fraction
FOR CONSTRUCTION
TOTAL HOURLY HEAT LOSS FOR ROOM
QATF BY
t7,622
EnergyPro 6.5 by Energysoft User Number. 6712
RunCode: 2015-03-19T17.14:48
ID. Page 12 of 15
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Monterra, Plan 1-Revised
311912015
ROOM INFORMATION ,
DESIGN CONDITIONS
Room Name
Living
Outdoor Dry Bulb Temperature
1
112 OF
Floor Area
1,612.0 f ,'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor CLTD' Btu/hr
R-38 Roof(R.38.204.16)
(W) 1,612.0 X 0.0260 X 56.0 =
Z347
R-21 Wall (VV 19.2x6.16)
(N) 327.6 X 0.0690 X 23.0 =
520
Wood Door
(N) 24.0 X 0.5000 X 23.0 =
276
R-21 Wall (W..19.2x6.16)
(E) 298.4 X 0.0690 X 33.0 =
679
R-21 Wall (VV 19.2x6.16)
(S) 25.0 X 0.0690 X 26.0 =
45
R-21 Wall (W.19.2x6.16)
(W) 95.0 X 0.0690 X 33.0 =
216
'R-0 Wall
680.0 X 0.3560 X 0.0 =
0
X X =
X X =
Page Total
4,084
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded Unshaded
Fenestration
Orientation Area GLF Area GLF
Btu/hr
Window
(N) 0.0 X 15.3 + 16.0 X 15.3 =
245
Window
(N) 0.0 X 15.3 + 28.0 X 15.3 =
429
Window
(N) 0.0 X 15.3 + 16.0 X 15.3 =
245
Window
(N) 0.0 X 15.3 + 186.4 X 15.3 =
2, 853
Window
(E) 47.4 X 15.3 + 0.6 X 29.6 =
743
Window
(E) 0.0 X 15.3 + 13.8 X 29.6 =
408
Window
(E) 0.0 X 15.3 + 13.8 X 29.6 =
408
X + X =
X + IxL 1=
Page Total
5,330
Internal Gain
Btu/hr
Occupants
4 8 Occupants X 245 Btuh/occ. =
1,185
Equipment
1,612 Floor Area X 0•50 w/sgft =
2,751
Infiltration: 1.072
X 0.94 X 79.12 X 42 =
3,332
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
16,681
Latent Gain
CITY OF LA QUINTAE
tuihr
Occupants
Infiltration: 4,806
48 Occupants X
X 0.94 X 7s.12 X o.00514
B 11/§6JSAFETY DEP .
PROVED
= FOR CONSTRUCTION
750
1,826
Air Sensible
CFM ELA AW
nAlE BY
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
750
EnemyPra 6.5 by EnemySoft
User Number. 6712 RunCodec 2015-03-1017.14.48 4D: Page 13 of 15
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Monterra, Plan 1-Revised 3/19/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
Indoor Dry Bulb
Opaque Surfaces
R-38 Roof(R.38.204.16)
R-21 Wall (W..19.2x6.16)
R-21 Wall (,V 19.2x6.16)
R-21 Wall (W..19.2x6.16) -
R-21 Wall (W..19.2x6.16)
*R-0 Wall
Orientation
W
(N)
(E)
(S)
(W1
Sleeping Outdoor Dry Bulb Temperature
1,568.0 ft2 Outdoor Wet Bulb Temperature
70 OF Outdoor Dailv Ranae:
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
1,568.0
0.0260
56.0
187.0
0.0690
23.0
137.0
0.0690
33.0
526.0
0.0690
26.0
366.0
0.0690
33.0
680.0
0.3560
0.0
Page Total
Items shown with an asterisk (*) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
IFenestration
Window
Window
Window
Window
Window
Window
Window
Window
Window
Gain
Orientation
Shaded Unshaded
Area
X
X
X
X
X
GLF
+
+
+
+
+
Area
X
X
X
X
X
GLF
=
=
=
=
0.0X
15.3+
1&0x
29.6=
0.0
15.3
36.0
15.3
0.0
15.3
6.0
15.3
0.0X
15.3+
36.0X
15.3=
0.0
15.3
6.0
15.3
0.0X
15.3+
36.0X
15.3=
0.0
15.3
54.0
15.3
0.0x
15.3+
10.0x
0.0
15.3
10.0
Page Total
4.7 Occupants
1,568 Floor Area
X 245 Btuh/occ.
X 0-,W I w/sgft =
Infiltration: 1.072 X 0.94 X 76.96 X 42 =
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
Occupants 4 7 Occupants X
Infiltration: 4,806 X 0.94 X 76.96 X 0.00514 =
Air Sensible CFM ELA AW
LA QUI
BUILDING & SAFETY I
APPROVE
112 OF
78 OF
34 OF
Btu/hr
2, 283
297
312
9
8313
B
532
550
92
550
92
550
825
296
3,783
Btu/hr
1,152
Z676
3,241
17,117
Btulhr
H
)T. 1
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 1 - ' ' `- - • • -
- ----V291
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Monte►Ta, Plan 1-Revised
311912015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name SleePing
Outdoor Dry Bulb Temperature 112 OF
Floor Area 1,568.0 flz
Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 70 T
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U-Factor
CLTD' Btu/hr
X
X =
X
X =
X
X =
X
X
X
X =-
X
X =
X
X =
X
X =
X
X =
Page Total 0
Items shown with an asterisk (*) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area GLF Btu/hr
Window (WJ 0.0 x 15.3 +
54.0 X 29.6 = 1,596
x +
x _
X +
X
X +
X
x +
X =
X +
X =
X +
X =
X +
X =
X +
X =
Page Total 1,59
Internal Gain
Btu/hr
Oocupants 4 7 Occupants X 245
Btuh/occ. = 1,152
Equipment 1,568 Floor Area X 0.50
W/sue
Infiltration: 1.072 x 0.94 x 76.96 x 42 =
3,241
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
I7 17
Latent Gain
n
I-Y OF LA QU0' JAir
Occupants 4 7 Occupants x 1
MLqW4G& SAFEZY DEP . 7 9
AP r ROV
Infiltration: 4,806 x 0.94 x 76.96 x 0.00514 =
FOR CONSTRUC ION 1,7
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM DATE ____—
Ene Pro 6.5 by EnergySoft User Number. 6712 RunCode: 2015-03-19T17:14.48 Q
Page 15 of 15
�.�..i...';► l t yr �iimr'UAA%oc 6..;MUD
Project Name: Monterra Plan 1 Calculation Date/Time: 16:56, Thu, Mar 19, 2015
CFI R-PRF=01
Page 1 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xmi
GENERAL INFORMATION
01
Project Name
Monterra Plan 1
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2015
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2013-3c (710)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.5
10
Building Type
Single Family
11
Front Orientation (dog/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (FTZ)
3180
16
Number of Zones
2
16
Slab Area (FTZ)
3180
17
Number of Stories
1
18
Addition Cond. Floor Area
N/A
19
Natural Gas Available
Yes
20
Addition Slab Area (FTZ)
N/A
21
Glazing Percentage (%)
18.5%
Registration Number: 214-NO163383B-000000000-0000 Registration Date/Time: 2015-03-19 17:13:20 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-03-1916:58:07
LGRIIrIVMIC Vr VV I GC- kcalvc%IIMUD
Project Name: Monterra Plan 1 Calculation Date/Time: 16:56, Thu, Mar 19, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xmi
CF1 R-PRF-01
Page 2 of 10
ENERGY USE SUMMARY
Energy Use Standard Proposed Compliance Percent
(kTDV/ft2-yr) Design Design Margin Improvement
Space Heating 1.20 0.98 0.22 18.3%
Space Cooling 96.90 88.32 8.58 8.9%
IAQ Ventilation 1.18 1.18 0.00 0.0%
Water Heating 8.07 7.61 0.46 5.7%
PV Credit - 0.00 0.00 -
North Facing Compliance Total 107.35 98.09 9.26 8.6%
Space Heating 1.20 1.47 -0.27 -22.5%
Space Cooling 96.90 92.21 4.69 4.8%
IAQ Ventilation 1.18 1.18 0.00 0.0%
Water Heating 8.07 7.61 0.46 5.7%
PV Credit - 0.00 0.00 --
East Facing Compliance Total 107.35 102.47 4.88 4.5°k
Space Heating �m 0 1 77 �, , -0.57-47.5%
Space Cooling 4 96 90 '' 9 / rr 85.90E 11.00 11.4%
IAQ Ventilation 1 1$ ,. 11$ 0.00 0.0%
g ..
0.46 5.7%
Water Heating *° ' 8 O7 7.6t
P ..
PV Credit W = 0.00 0.00 -
South Facing Compliance Total 107.36 96.46 10.89 10.1%
Space Heating 1.20 1.29 -0.09 -7.5%
Space Cooling 96.90 91.10 5.80 6.0%
D IAQ Vren�tila ion 1.18 1.18 0.00 0.0%
m
V�eQ ing 8.07 7.61 0.46 5.7%
0 > r-' t -- 0.00 0.00 --
VA Coin ilance Total 107.35 101.18 6.17 6.7%
-�
4®D
M
0 q
I M t`
0 (D
=°
Registration Number: 214-No163383B-000000000-0000 Registration Date/71me: 2015-03-19 17:13:20 HERS Provider: C8ICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-03-19 16:58:07
GEKTIFICATE OF COMPLIANCE - RESIUE14TIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1
Calculation Description: Title 24 Analysis
Calculation Date/Time: 16:56, Thu, Mar 19, 2015
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xm1
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
• Exposed slab floor In conditioned zone
HERS FEATURE SUMMARY
CF1 R-PRF-01
Page 3 of 10
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Verified low -leakage ducts located entirely In conditioned space
Domestic Hot Water System Verifications:
• —None —
ENERGY DESIGN RATING
This is the sum of the annual TDV energy'con§umption?or.=energy use componentsiricluded`in the, performance complianceapproach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and tampon ntnvregulated byymtle.24Part 6 (such as dvmesticJappliancs and consumer electronics) and accounting for the annual TDV energy offset by an I
on -site renewable energy system.+
Reference Energy Use I Energy Design Ratan§ Margin I Percent Improvement I
Total Energy (kTDV/f2-yr)* 148.48' " 4.88 3.3%
* includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
02
03
04
05
06
07
03
m Prod Naomi
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Mo1.14 Ic 1
3180
1
6
2
0
1
O -rI
Cn i >�
� c®m C)
jm:�c
o®M�
s ration Number::-2li4' t
0000000-0000 Registration Date/lime: 2015-03-19 17:13:20
- 2013 Residential Compliance Report Version - CF111-02272015-710
HERS Provider: CaICERTS Inc.
Report Generated at: 2015-03-1916:58:07
CA
i.mml iri%. i yr %,uAnrLIACe - kralucri i wL r1EKr01kArvU= w.;01PLIAN%.c IITHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 16:56, Thu, Mar 19, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xm1
CFI R-PRF-01
Page 4 of 10
ZONE INFORMATION
01
02
03
04
06
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Living Zone
Conditioned
HVAC 11
1612
11.4
DHW Sys 1
Sleeping Zone
Conditioned
HVAC 22
1568
10
DHW Sys 1
OPAQUE SURFACES
01
02
03
04
06
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window Area (ft)
Tilt (deg)
N Wall
Living Zone
R-21 Wall (W 19.2x6.16)
0
Front
598
246.4
90
E Wall
Living Zone ',
R-21 Wall (W 19.2x6.16)
90
Left
374
75.6
90
S V1a11
Living Zone '.'.
R-21 Wall (W 19.2x6.16)
180
Bads
25
0
90
W Wall
Living Zone
R-21 Wall (W 19.2x6.16)
270
Right
95
0
90
R-38 Roof*
ng Zone _ „
R 3i3 Roof(Fi3$ 2x1 ,16) s ...
�:,.
1612
N Wall 2
: • Sleeping:Zone
R 27 gV11a11(1i1h2x616)
'` U ,
Front
187
0
90
E V1a112
SleengZonR
21 1lll{a/1L19 26.16
07-
9Q
nLeft`"`
155
18
90
S M112
Sleeping'Zone ,y '
._.
R-21C Wall (VIt19.2xEi:16) r'
180 G
`Bads
700
174
90
W Wall 2
Sleeping Zone
R-21 Wall (W 19.2x6.16)
270
Right
440
74
90
R-38 Roof 2
Sleeping Zone'
R-38 Roof(R.38.2x14.16)
1568
ATTli
01 00 1.
Nam r-
ic Livings
i Sleep!
Z X 9.
Cf)
�®D
171
\ M
C:
M -< C
Z
Z®m
02
03
04
06
06
07
08
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
dtic RoofLiving Zone
Unventilated
4.36764
0.1
0.85
Yes
No
:ic RoofSleeping Zone
Unventilated
4.36764
0.1
0.85
Yes
No
Registration Number: 214-N0163383B-000000000-0000 Registration Date/Time: 2015-03-19 17:13:20 HERS Provider: CaICERTS Inc.
CA Building Energy. Efficiency Standards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-03-1916:58:07
Gic-ml iri,,r►i E of GvMr-LIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 16:56, Thu, Mar 19, 2015
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xm1
CF1 R-PRF-01
Page 5 of 10
WINDOWS
01
02
03
04
06
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multlpll
or
Area
(ft2)
U-factor
SHGC
Exterior Shading
Window
Window
N Wall (Front-0)
2.0
8.0
1
16.0
0.32
0.24
Insect Screen (default)
Window 2
Window
N Wall (Front-0)
2.5
8.0
1.4
28.0
0.32
0.24
Insect Screen (default)
Window 3
Window
N Wall (Front-0)
2.0
8.0
1
16.0
0.32
0.24
Insect Screen (default)
Window 4
Window
N Wall (Front-0)
23.3
8.0
1
186.4
0.32
0.24
Insect Screen (default)
Window 5
Window
E Wall (Left-90)
6.0
8.0
1
48.0
0.32
0.24
Insect Screen (default)
Window 6
Wndow
E Wall (Left-90)
-
--
1
13.8
0.32
0.24
Insect Screen (default)
Window 7
Window
E Wall (Left-90)
-
--
1
13.8
0.32
0.24
Insect Screen (default)
Window 8
Window
E Wall 2 (Left-90)
-
--
1
18.0
0.32
0.24
Insect Screen (default)
Window 9
Window
S Wall 2 (Back-180)
-
--
1
36.0
0.32
0.24
Insect Screen (default)
Window 10
Window
S;Wall 2 (Back-180)
-
-
1
6.0
0.32
0.24
Insect Screen (default)
Window 11
Window
S.Vltall 2 (Back-180)
-
--
1
36.0
0.32
0.24
Insect Screen (default)
Window 12
Window
SU1faU 2 (Back 180) -r.,;
-=`
1
6.0
0.32
0.24
Insect Screen (default)
Window 13
Window
5 VIhIf (Bads 180) ' � ' "'
r,
�' ` - €?
1 ,
, 36.0
0.32
0.24
Insect Screen (default)
Window 14
Window
.,,sp �S V1Fall2_(EtAck 180) „. �..
�- �,.
$;1 k
54.0
0.32
0.24
Insect Screen (default)
Window 15
Window
W Vfall 2 (Right-270)
-
--
1
10.0
0.32
0.24
Insect Screen (default)
Window 16
Window
V11IVall 2 (Right-270)
-
--
1
10.0
0.32
0.24
Insect Screen (default)
Window 17
Window
W Wall 2 (Right-270)
-
--
1
54.0
0.32
0.24
Insect Screen (default)
r,
DOOR
r' 01
02
03
04
�Na
Side of Building
Area 01:2)
U-factor
Q off")
N Wall
24.0
0.50
Registration Number: 214-N0163383B-000000000-0000 Registration Date/Time: 2015-03-19 17:13:20 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-03-1916:58:07
Cr_ml rrn,:Al IE OF COMPLIANCE - RESIUENTIAL PERFORMANCE COSPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 16:56, Thu, Mar 19, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-Rev-Helton Def6rd-14.xml
CF1 R-PRF-01
Page 6 of 10
OVERHANGS AND FINS
01
02
03
04
06
06
07
08
09
10
11
1 12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DIstL
Bot Up
Depth
Top Up
Dist R
Bot Up
Window
11
0.1
11
11
0
0
0
0
0
0
0
0
0
Window 2
11
0.1
11
11
0
0
0
0
0
0
0
0
0
Window 3
11
0.1
11
11
0
0
0
0
0
0
0
1 0
0
Window 4
14
0.1
14
14
0
0
0
0
0
0
0
0
0
Window 5
10
0.1
10
10
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type "
Construction Type
Framing
R-value
U-value
Assembly Layers
Cavity/Frame: no insul. /2x4 Top Chid
Attic RoofLiving Zone
Attic.Roofs
2x ,Top Cha deaf Roof Truss 24`
tv'
�
•Roof Deck V46od Siding/sheathing/decking
V�bod F:rametl'Ceiling
) it b
,; none
0.644
•Roofing: Light Roof (Asphalt Shingle)
zz
•Inside Finish: Gypsum BoardCeilings
(below-•
- .:
"?
✓ity
Ca /Frame: R-9.1 /2x4
R-38 Roof(R.38.2xl4.16)
attic)
V1bod Framed Ceiling
2k4 @ 16 in: O:C:%
R 38
0.025
Over Floor Joists: R-28.9 insul.
4
• Inside Finish: Gypsum Board
• Cavity/Frame: R-2112x6
• Exterior Finish: Mood
R-21 Wall (VV 1 9.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
• Cavity/Frame: no insul. /2x4 Top Chid
D
2x4 Top Chord of Roof Truss @ 24
• Roof Deck. VWod Siding/sheathing/decking
Attic
R*Sleeping ZonC
Attic Roofs
V1bod Framed Ceiling
in. O.C.
none
0.644
• Roofing: Light Roof (Asphalt Shingle)
r—
SLAB F
ORS
0 ,)
02
03
04
05
06
07
Na
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
-lyover
Living Zone
ill
27
None
1
No
and Su
Living Zone
1501
61
None
0
No
Covered2§1&Ldi
Sleeping Zone
340
35
None
1
No
rd Surface Islab
Sleeping Zone
1228
93
None
0
No
I� �J
Registration Number: 214-No163383B-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-03-19 17:13:20
Report Version - CF111-02272015-710
HERS Provider: CaICERTS inc.
Report Generated at: 2015-03-1916:58:07
Gr-RS iri%IAI C OF COMPLIANCE - kE51DENTIAL PERFd�ANCIE COMPLIANCE METHOD
Project Name: Monterra Plan 1
Calculation Description: Title 24 Analysis
Calculation Daterrime: 16:56, Thu, Mar 19, 2015
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xmi
CF1 R-PRF-01
Page 7 of 10
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
ACH @ 50 Ps
Not Required
Not Required
Not Required
--
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (°k)
DHW Sys 1 - 1/1
DHW
Pipe Insulation, All Lines
DHW Heater 1
1
.0%
WATER HEATERS
01
02
03 04
05
06
07
08
Name
Heater Element Type
Tank Volume
Tank Type (gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
(Fraction)
DHW Heater 1
Natral,,Gas
�SmaIl,Sto ,gem ,,,, 50,.M, ;,•
0.62
40000-Btu/hr
0
0
` f 5
—777
WATER HEATING - HERS VERIFICATION�
s
01
04 "'
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1 /1
--
—
—
—
—
—
SPACE C�IDITIONI G
—1 01w
02
03
04
06
06
ysrn
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
Cool! Compo6e-nL i o ponent 1:Air
istributic a: Fan 1:1
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
Cool ompc� ti ponent 2:Air
.
f&Wributl sFan 2:1
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
0M��
5®MZ
.I>
Registration Number: 214-N0163383B-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-03-19 17:13:20
Report Version - CF111-02272015-710
HERS Provider: CaICERTS Inc.
Report Generated at: 2015-03-19 16:58:07
Project Name: Monterra Plan 1 Calculation Date/Time: 16:56, Thu, Mar 19, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xmi
cF1 R-PRF-01
Page 8 of 10
HVAC - HEATING UNIT TYPES
01
02
03
Name
Type
Etflclency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 2
CntriFurnace - Fuel -fired central furnace
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
11.585
13.5
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Cooling Component 2
SplitAirCond
11.585
13.5
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
"
01 02 �, ; 403 � � _ 04 05 06
Name
Verifled;Alrflov� 1'
AiiflgwTarget�
erlfied EER .
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
'aRequired
Not Required
Not Required
Not Required
Cooling Component 2-hers-cool
Required :.
350
Not Required
Not Required
Not Required
HV MS
D 01 Q3 (� 02
03
04
OS
06
07
rrl — Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
i DistribuTZ DuctsinAll
Sealed and tested
8
Attic
None
Air Distribution System
r.s�
1-hers-list
i Distribuii tgm 2n DuctslnAll
Sealed and tested
8
Attic
None
Air Distribution System
2-hers-list
pAJ
HV DISTRI TLTN rHEffVkFRIFICATION
02
03
04
05
06
07
08
O7 ® 0
;Tame -0
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air tribution System 1- ers-d st
Required
6.0
Required
Not Required
Not Required
Not Required
--
Air ion ystem 2-hers-list
Required
6.0
Required
Not Required
Not Required
Not Required
--
Registration Number: 214-No163383B-000000000-0000 Registration Date/Time: 2015-03-19 17:13:20 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-03-19 16:58:07
t+cml iri%; .. t yr %,WMrLIAN1:e - kcolur-A I IAL rtEmr0...A E GX,._1LIANGE I... rHOQ
Project Name: Monterra Plan 1
Calculation Description: Title 24 Analysis
Calculation Date/Time: 16:56, Thu, Mar 19, 2015
Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xm1
GF1 R-PRF-01
Page 9 of 10
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
HVAC Fan 2-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM " j
f. IAQrWattsiCM,'
,., �. _IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
83 %� s
€i'25
Defaurlt .
. . r,
0
Required
q
a
0 U,
C
m ®� ®_
0
0-n
�0>DZI
0<� ,M
0
Z® U
Registration Number: 214-No163383B-000000000-0000 Registration Date/Time: 2015-03-19 17:13:20 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-03-1916:58:07
4
L�..1...:,,.. t ...ralC,v,;,w. -
Project Name: Monterra Plan 1 Calculation Date/Time: 16:56, Thu, Mar 19, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-Rev-Helton Deford-14.xml
CF7 R-PRR-01
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Turrri-�caZL`
Company:
Signature Date:
Scott Design and Title 24, Inc.
2015-03-19 17:13:20
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified;on-this Certificate of Compliance are,consistenW the information provided on other applicable compliance documents,
th
r .. Y
worksheets, calculations, plans and specifications subrrAe to the enforcement age► r fo pprovall with this.tiuilding permit application.
,.,
Responsible Designer Name: &
k
Ftestiolsible Designer Signature
Tim Scott
Company:
'Date Signed:
Scott Design and Title 24, Inc:
2015-03-19 17:13:20
Address:
License:
77085 Michigan Drive
NA
City/
Pal CA 90-- 1L,
Phone:
esert,
(760) 200-4780
� z0
� �
)0
����
Digitally i ned bys-al%'g al signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the
informati
®mom
Registration Number: 214-N0183383B-000000000-0000 Registration Date/Time: 2015-03-19 17:13:20 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-03-1916:58:07
I BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Monterra, Plan 4
55-101 Monroe
La Quinta, CA 92253
Project Designer:
Helton, DeFord & Associates
17411 Irvine Blvd, Suite O
Tustin, CA 92780
(909) 957-4550
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
77085 Michigan Drive
Palm Desert, CA 92211
(760) 200-4780
I
CITY 0
BUILDING & SAFETY DEPT
p VCD
CONS'UCTION
DATE I7.I4 I / c
Job Number: RECEIVE
NOV 18 2015
CITY OF LA Date:
COMMUNITY E ELOPMENT
11 /4/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 6.7 by EnergySoft User Number. 6712 ID:
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF-1 R-PRF-01-E Certificate of Compliance
Form RMS-1 Residential Measures Summary
Form MF-1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
Zone Load Summary
Room Load Summary
Room Heating Peak Loads
Room Cooling Peak Loads
1
2
3
13
14
18
19
20
21
22
I EnergyPro 6.7 by EnergySoft Job Number: ID: User Number: 6712
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:32, Wed, Nov 04, 2015
CF1 R-PRF-01
Pag6 1 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-Helton Deford-13.xml
GENERAL INFORMATION
01
Project Name
Monterra Plan 4
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2015
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2013-4 (744)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.6
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ftz)
3650
15
Number of Zones
1
16
Slab Area (ftz)
3650
17,
Number of Stories
1
18
Addition Cond. Floor Area
N/A
T19
Natural Gas Available
Yes
20
Addition Slab Area (ftz)
N/A
21
Glazing Percentage (%)
19.0%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below:
yf+B
Registration Number: f•'a`r'
CA Building Energy Efficiency Stan`daids - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 16:33:13
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:32, Wed, Nov 04, 2015
CF1 R-PRF-01
Page` 2 of 1 Of
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-Helton Deford-13.xmi
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.17
0.99
0.18
15.4%
Space Cooling
95.31
79.48
15.83
16.6%
IAQ Ventilation
0.81
0.81
0.00
0.0%
Water Heating
7.03
6.80
0.23
3.3%
PV Credit
----
0.00
0.00
----
North Facing Compliance Total
104.32
88.08
16.24
15.6%
Space Heating
1.17
° 127
-0.10
-8.5%
Space Cooling
95.31
86.36
8.95
9.4%
IAQ Ventilation
0.81
0.81
0.00
0.0%
Water Heating
7.03
6.80
0.23
3.3%
PV Credit
0.00
0.00
----
East Facing Compliance Total
104.32
~
95.24
9.08
8.7%
Space Heating
1.17
1.26
-0.09
-7.7%
Space Cooling
95.31
77.89
17.42
18.3%
IAQ Ventilation
0.81
`�
0.81
0.00
0.0%
Water Heating
7.03
6.80
0.23
3.3%
PV Credit
----
0.00
0.00
----
South Facing Compliance Total
104.32..-,,;
86.76
17.56
16.8%
Space Heating
1 1T •
1.15
0.02
1.7%
Space Cooling
95 31
85.29
10.02
10.5%
IAQ Ventilation
0.81
0.81
0.00
0.0%
Water Heating
7.03
6.80
0.23
3.3%
PV Credit
----
0.00
0.00
----
West Facing Compliance Total
104.32
94.05
10.27
9.8%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as conditionfior meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins r
are.
Registration Number:>
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFiR-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 16:33:13
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4
Calculation Description: Title 24 Analysis
HERS FEATURE SUMMARY
Calculation Date/Time: 16:32, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 4-Helton Deford-13.xml
CF1 R-PRF-01
Pag6 3 of 10
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Ducts located entirely In conditioned space
Domestic Hot Water System Verifications:
• -- None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on -site renewable energy system.
Reference Energy Use _
Energy Design Rating
Margin
Percent Improvement
Total Energy (kTDV/f2-yr)*
143.85
134.77
9.08
6.3%
* includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION{ "✓
01
02
03'
04
05
06
07
Number of Dwelling
Number of Ventilation
Number of Water
Project Name
Conditioned Floor Area (ft2)
°� ,;Units
Number of Bedrooms
Number of Zones
Cooling Systems
Heating Systems
Monterra Plan 4
3650�,
��1
3
1
0
1
ZONE INFORMATION m
01
02°'
03
04
05
06
07
Zone Name
Zone Type f ',Q
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Plan 4
Conditioned
HVAC 1, 2 & 31
3650
9
DHW Sys 1
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 16:33:13
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:32, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-Helton Deford-13.xml
CF1 R-PRF-01
Pag6 4 of 10
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door Area (ft2)
Tilt (deg)
N Wall
Plan 4
R-21 Wall (W.19.2x6.16)
0
Front
860
244.019
90
E Wall
Plan 4
R-21 Wall (W.19.2x6.16)
90
Left
730
73
90
S Wall
Plan 4
R-21 Wall (W19.2x6.16)
180
Back
860
282.5
90
W Wall
Plan 4
R-21 Wall (W19.2x6.16)
270
Right
750
93.5
90
R-38 Roof
Plan 4
R-38 Roof(R.38.2x14.16)
3650
ATTIC "
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Ala"'
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Plan 4
Attic RoofPlan 4
Ventilated
4 3,6764
0.1
0.85
No
No
F
°.:x.
7
Registration Number: }
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 16:33:13
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:32, Wed, Nov 04, 2015
CF1 R-PRF-01
Pag6 5 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-Helton Deford-13.xml
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multlpll
er
Area
(ft2)
U-factor
SHGC
Exterior Shading
1.5X8 F
Window
N Wall (Front-0)
1.3
8.0
1.154
12.0
0.32
0.24
Insect Screen (default)
3.5X8 FD
Window
N Wall (Front-0)
3.5
8.0
1
28.0
0.32
0.24
Insect Screen (default)
1.5X8 F 2
Window
N Wall (Front-0)
1.3
8.0
1.154
12.0
0.32
0.24
Insect Screen (default)
16X8 PD
Window
N Wall (Front-0)
18.0
8.0
0.889
128.0
0.32
0.24
Insect Screen (default)
8X8 PD
Window
N Wall (Front-0)
----
----
1
64.0
0.32
0.24
Insect Screen (default)
2X5 SH
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 SH 2
Window
E Wall (Left-90)
-
1
10.0
0.32
0.24
Insect Screen (default)
3X5.5 SH
Window
E Wail (Left-90)
1
16.5
0.32
0.24
Insect Screen (default)
3X5.5 SH 2
Window
E Wall (Left-90)
- -
--
1
16.5
0.32
0.24
Insect Screen (default)
2X5 F
Window
E Wall (Left 90)
...:...:..:
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 2
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
6X8 FD
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
5X4.5 SL
Window
S Wall (Back-180)
----
----
1
22.5
0.32
0.24
Insect Screen (default)
16X8 PD 2
Window
S Wall (Back 180)
16.0
8.0
1
128.0
0.32
0.24
Insect Screen (default)
6X8 FD 2
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
6X6 SL
Window
S Wall (Back-180),,
----
----
1
36.0
0.32
0.24
Insect Screen (default)
2X5 F 3
Window
W Wall (Right 270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 4
Window
W Wall (Right=270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5.5SH
Window
W Wall (Right-270)
----
----
1
11.0
0.32
0.24
Insect Screen (default)
5X5.5 F
Window
W Wall (Right-270)
----
----
1
27.5
0.32
0.24
Insect Screen (default)
2X5.5 SH
Window
W ;Wall (Right-270)
----
--
1
11.0
0.32
0.24
Insect Screen (default)
3X8 FD
Window
1N,Wall (Right 270)
w ,
-
1
24.0
0.32
0.24
Insect Screen (default)
''`
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 16:33:13
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4
Calculation Description: Title 24 Analysis
Calculation Date/Time: 16:32, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 4-Helton Deford-13.xml
CF1 R-PRF-01
Pag6 6 of 1 Or
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DIstL
Bot Up
Depth
Top Up
Dist R
Bot Up
1.5X8 F
10
0.1
10
10
0
0
0
0
0
0
0
0
0
3.5X8 FD
10
0.1
10
10
0
0
0
0
0
0
0
0
0
1.5X8 F 2
10
0.1
10
10
0
0
0
1 0
0
0
0
0
0
16X8 PD
4
0.1
4
4
0
Oaf
0
0
0
0
0
0
0
16X8PD2
4
0.1
4
4
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
�?
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing'
R-value
U-value
Assembly Layers
Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord`of'Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofPlan 4
Attic Roofs
Wood Framed Ceiling
In O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Ceilings below
9 (
fi
Cavity / Frame: R-9.1 / 2x4
R-38 Roof (R.38.2x14.16)
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
Inside Finish: Gypsum Board
Cavity/Frame: R-21 /2x6
s= w
Exterior Finish: Wood
R-21 Wall (W.19.2x6.16)
Exterior Walls
Wood Framed Wall:
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
SLAB FLOORS
01
02 7;
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
Plan 4 ` H
430
52
None
0.8
No
Hard Surface Slab
Plan V
3220
263
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII) £`;"`
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
---
Registration Number: `
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 16:33:13
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4
Calculation Description: Title 24 Analysis
Calculation Date/Time: 16:32, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 4-Helton Deford-13.xml
CF1 R-PRF-01
Page 7 of 10f
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 - 1/1
DHW
Parallel Piping
DHW Heater 1
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
'q, Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.62
40000-Ettu/hr
0
0
WATER HEATING - HERS VERIFICATION
S
01
02
03 a
04
05
06
07
Recirculation
Central DHW
Name
Pipe Insulation
Parallel Plping'..,,
Compact Distribution
Point -of Use
Control
Distribution
DHW Sys 1 - 1/1
---
---
---
SPACE CONDITIONING SYSTEMS
01
02
:` 03
04
05
06
SC Sys Name
System Type
_ Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC 1, 2 & 31
Other Heating and Cooling'
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01
02
03
Name
Type
Efficiency
Heating Component 1a
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Registration Number: Po."
r
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 16:33:13
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation DatelTime: 16:32, Wed, Nov 04, 2015
CF1 R-PRF-01
Pag4 8 of 101
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-Helton Deford-13.xml
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
12
14
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Not Required
Required
mo
HVAC - DISTRIBUTION SYSTEMS°
01
02
03
%` 04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuclslnAll
`
Sealed and tested �'
8
Conditioned zone
None
Air Distribution System-hers-dist
go
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03 a,; `"
04
05
06
07
08
Duct Leakage
Duct Leakage
Verified Duct
Verified Duct
Burled
Deeply Burled
Low -leakage
Name
Verification
T34',t'(0
Location
Design
Ducts
Ducts
Air Handler
Air Distribution System 1-hers-dist
Required-
6.0
Required
Not Required
Not Required
Not Required
---
HVAC -FAN SYSTEMS
01
02
03
04
Name
'r Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION '
01-,
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts1CFM)
HVAC Fan 1-hers-fan -p
Required
0.58
Registration Number:';': "
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 16:33:13
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:32, Wed, Nov 04, 2015
CF1 R-PRF-01
Pagi 9 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-Helton Deford-13.xml
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%a)
HERS Verification
SFam IAQVentRpt
66.5
0.25
Default
0
Required
�3
g
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 16:33:13
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation DatelTime: 16:32, Wed, Nov 04, 2015
CF1 R-PRF-01
Page 110 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-Helton Deford-13.xml
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc,
11/4/2015
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State i :
Fllm Desert, CA 92211
Phone: ' -
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility fort he building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate ofCompliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations. gt'f
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency46 approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Jim Deford
Company: r6l•.
Date Signed:
Helton, DeFord & Associates a=
Address: �.; `
License:
17411 Irvine Blvd, Suite O
City/State/Zip:
Phone:
Tustin, CA 92780
(909) 957-4550
Registration Number:-f`
CA Building Energy Efficiency Staridards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 16:33:13
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Monterra, Plan 4
Building Type 10 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111412015
Project Address
55-101 Monroe La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,656
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features Status
Roof Wood Framed Attic
R 38 3,650 New
Wall Wood Framed
R 21 2,507 New
Door Opaque Door
- no insulation 0 New
Slab Unheated Slab -on -Grade
- no insulation 3,650 Perim = 315' New
FENESTRATION
Orientation Area(ft2)
I Total Area: 693 Glazing Percentage: 19.0 New/Altered Average U-Factor: 0.32
U-Fac SHGC Overhang Sidefins Exterior Shades Status
Front (N) 52.0
0.320
0.24 10.0 none Bug Screen New
Front (N) 128.0
0.320
0.24 4.0 none Bug Screen New
Front (N) 64.0
0.320
0.24 none none Bug Screen New
Left (E) 73.0
0.320 0.24 none none Bug Screen New
Rear (S) 154.5
0.320 0.24 none none Bug Screen New
Rear (S) 128.0
0.320 0.24 4.0 none Bug Screen New
Right (iM 93.5
0.320 0.24 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling Min. Eff Thermostat Status
2 Central Fumace
80 % AFUE
Split Air Conditioner 14.0 SEER Setback New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
HVAC 1, 2 & 3 Ducted
Ducted Conditioned 8.0 New
WATER HEATING
Qt - Type
Gallons Min. Eff Distribution Status
1 Small Storage Gas
50
0.62 Parallel Piping New
EnemyPro 6.7 by EnerqySoft User Number. 6712
RunCode: 2015-11-04T16.43:11 ID: Page 13 of 24
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration that meets the requirements of §10-111(a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal enuttance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CFIR.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U-factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ 150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R-value.
§150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U-
factor).
§ 150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U-factor.
In Climate Zones 14 and 16 a Class U vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§ 150.0(g)l:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class H
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class 11 vapor retarder shall be placed over the earth floor of
§ I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of §I 10.8(g).
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U-factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§150.0(e)1C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §l 10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§ 150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in § 150.0(h)2.
§ I50.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§ 150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.0(j)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§ 150.00)2C:
Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ 150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ 150.00)3B:
or Class H vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class H vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSPSMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/a inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross -sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ 150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R-value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ 150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§ 150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ 150.0(m)l l:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§ 150.0(m)13:
space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy 5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ 150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of > 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of 5 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§ 150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any Pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
-§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately nix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ 150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§150.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§ 150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)1C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting per electrical box.
§ 150.0(k)lD:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ I50.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ 150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ I50.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ I50.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in § 150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§ 150.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
ftmctionality of a dimmer according to §110.9, and complies with all other applicable requirements in §150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ 150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ 150.0(k)9B:
following requirements:
i. Shall comply with § 150.0(k)9A; or
ii. Shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I50.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4. § 140.7 and § 141.0.
§ 150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ 150.0(k)l l:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9, § 130.0, § 130.1, § 130.4, § 140.6, and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ 150.0(k)12B:
i. Comply with the applicable requirements in § 110.9, § 130.0, § 130.1, § 140.6 and § 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10(b) through § 110.10(e).
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.
�HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Monterra, Plan 4
Date
11/4/2015
System Name
HVAC 1, 2 & 3
Floor Area
3,650
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 2,150
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
38,511
5,213
880
40,235
Total Output (Btuh)
178,000
0
Output (Btuh/sgft)
48.8
557
479
Cooling System
0
0
Output per System
57,500
0
0
0
0
Total Output (Btuh)
115,000
5,887
5,213
-5,887
Total Output (Tons)
9.6
557
479
Total Output (Btuh/sgft)
31.5
Total Output (sgft/Ton)
380.9
45,513
35,305
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow (cfm)
4,000
Carrier 24ACA460/58CVX110
78,647
15,469
178,000
Airflow (cfm/sgft)
1.10
Airflow (cfm/Ton)
417.4
Outside Air (%)
0•0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
78,647
15,469
178,000
Jan 1 AM
Outside Air (cfm/sgft)
0.00
I
Note: values above given at ARI conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS (Airstream
Temperatures at Time of Heating Peak)
26 OF 72 OF
Outside Air
0 cfm Supply Fan
4,000 cfm
72 OF
.+—
73 OF 115 OF
m
Heating Coil
J" -F
.-„ :..-....
115 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Tem eratures at Time of Cooling
Peak
112178 OF 70 / 59 OF 72 / 60 OF 53 / 52 OF
Outside Air _
0 cfm Supply Fan Cooling Coil
4,000 cfm.............--~
70 ! 59 OF
<_....
53 / 52 °F
�•
53.1 /o
° ROOM 2
A
70 / 59 OF
EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-11-04T16:43:11
ID: Page 18 of 24
ZONE LOAD SUMMARY
Project Name
Monterra, Plan 4
Date
111412015
System Name
HVAC 1, 2 & 3
Floor Area
3,650
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
Sensible
Plan 4
1.0
0
Aug 3 PM
2,150
38,511
5,213
880
40,235
TOTALS
0
0
0
0
Aug 3 PM
38,511
5,213
40,235
(BLOCK LOAD)
EnergyPro 6.7 by EnergySoR User Number: 6712 RunCode: 2015-11-04T16.43:11 ID: Page 19 of 24
ROOM LOAD SUMMARY
Project Name Date
Montetm, Plan 4 111412015
System Name Floor Area
HVAC 1, 2 & 3 3,650
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name I Room Name Mult. I CFM I Sensible I Latent CFM Sensible I Latent CFM Sensible
Plan 4 1 Plan 4 1 1 Z 1501 38,5111 5,2131 2,1501 38,5111 5, 213 880 40, 235
PAGE TOTAL
TOTAL"
Z 150
38,5111
5,2131
880
40,235
2,150
38,5111
5,2131
880
40,2351
' Total includes ventilation load for zonal systems.
EnergyPrp 6.7 by Ene Soft User Number: 6712 RunCode: 2015-11-04T16:43:11 ID: Page 20 of 24
ROOM HEATING PEAK LOADS
Project Name
Monterra, Plan 4
Date
111412015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Plan 4
Floor Area 3,650.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT 'F
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38Roof(R.38.2x14.16)
3,650.0
0.0260
46
4,365
R-21 Wall (W.19.2x6.16)
2,507.0
0.0690
46
7,957
Milgard Low-E Vinyl
693.0
0.3200
46
10,201
Slab -On -Grade
perim = 315.0
0.7300
46
10,578
Items shown with an asterisk (*) denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 3,650 X
Area
another room
9.00 X 0.266
Height ACH
Page Total
/ 60 ] X
AT
33,101
= 7,134
TOTAL HOURLY HEAT LOSS FOR ROOM 40,235
EnergyPro 6.7 by EnergySoR User Number: 6712 RunCode: 2015-11-04T16.43:11 ID: Page 21 of 24
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Monterra, Plan 4 1 111412015
ROOM INFORMATION' ' DESIGN CONDITIONS
Room Name
Plan 4
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,650.0 ft2
1
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
70 OF
Outdoor Dailv Range:
34 OF
Opaque Surfaces
R-38 Roof(R.38.2x 14.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
Orientation
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
3,650.0
0.0260
56.0
616.0
0.0690
23.0
657.0
0.0690
33.0
577.5
0.0690
26.0
656.5
0.0690
33.0
Page Total
Items shown with an asterisk (`) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
1.5X8 F
3.5X8 FD
1.5X8 F
16X8 PD
8X8 PD
2X5 SH
2X5 SH
3X5.5 SH
3X5.5 SH
Internal Gain
Orientation
(N)
(N)
(N)
(N)
(N)
(E)
(E)
(E)
(E)
Shaded Unshaded
Area
X
X
X
X
X
X
GLF
+
+
+
+
+
+
Area
X
X
X
X
X
X
GLF
=
=
=
=
=
-
0.0
15.3
12.0
15.3
0.0X
15.3+
28.0X
15.3=
0.0
15.3
12.0
15.3
0.0
15.3
128.0
15.3
0.0
15.3
64.0
15.3
0.0X
15.3+
10.0X
29.6=
0.0
15.3
10.0
29.6
0.0X
15.3+
16.5X
29.6=
0.0
15.3
16.5
29.6
Page Total
10.9 Occupants X 245 Btuh/occ. _
3,650 Floor Area X 0.50 W/sgft =
Infiltration: 1.064 X 0.94 X 150.55 X 42 =
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
10.9 Occupants X 1 155 Btuh/occ. _
Infiltration: 4,771 X 0.94 X 150.55 X 0.00523 =
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
Btu/hr
5, 314
1, 496
1, 036
1, 495
Btu/hr
184
429
184
1,959
980
296
296
488
488
5, 301
Btu/hr
2, 683
6,229
6,293
38,511
Btu/hr
1,697
3,516
1,697
User Number.-
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Monterra, Plan 4 111412015
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Plan 4
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,650.0 ft2
1
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
70 OF
Outdoor Dailv Range:
34 OF
Surfaces Orientation
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
2X5 F
2X5 F
6X8 FD
5X4.5 SL
16X8 PD
6X8 FD
6X6 SL
2X5 F
2X5 F
I Internal Gain
Orientation
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
-
0.0
15.3
10.0
29.6
0.0
15.3
10.0
29.6
0.0
15.3
48.0
15.4
0.0
15.3
22.5
1544
128.0
15.3
0.0
15.4
0.0
15.3
48.0
15.4
0.0
15.3
36.0
15.4
0.0
15.3
10.0
29.6
0.0
15.3
10.0
29.6
Page Total
10.9 Occupants X 245 Btuh/occ. _
3,650 Floor Area X 0.50 W/sgft =
Infiltration: 1.064 X 0.94 X 150.55 X 42 =
Air Sensible CFM ELA 4T
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
10.9 Occupants X 1 155 Btuh/occ. _
Infiltration: 4,771 X 0.94 X 150.55 X 0.00523 =
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
Btu/hr
Btu/hr
296
296
737
346
1,959
737
553
296
296
5,5151
Btu/hr
2, 683
6,229
6,293
38,511
Btu/hr
1,697
3,516
1.697
RunCode: 2015-11-04T16:43:11
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Monterra, Plan 4
111412015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Plan 4
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3, 650.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
Page Total
0
Items shown with an asterisk (*)
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area
GLF
Btu/hr
2X5.5SH
(IM 0.0 X 15.3 +
11.0
X 29.6 =
325
5X5.5 F
(1/10 0.0 X 15.3 +
27.5
X 29.6 =
813
2X5.5 SH
(W 0.0 X 15.3 +
11.0
X 29.6 =
325
3X8 FD
(IM 0.0 X 15.3 +
24.0
X 29.6 =
709
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
Page Total
2,172
Internal Gain
Btu/hr
Occupants
10•9 Occupants X 245
Btuh/occ.
=
2,683
Equipment
3,650 Floor Area X 0.50
W/sgft
Infiltration: 1.064
X 0.94 X 150.55 X 42 =
6,293
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
38,511
Latent Gain
Btu/hr
Occupants
10 9 Occupants X 155
Btuh/occ.
=
1,697
Infiltration: 4,771
X 0.94 X 150.55 X 0.00523 =
3,516
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,697
Ene Pro 6.7 by EnergySoft
User Number- 6712 RunCode: 2015-11-04T16:43:11 ID:
Page 24 of 24
y
t CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4
Calculation Description: Title 24 Analysis
Calculation Datelrime: 16:32, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 4-Helton Deford-13.xm1
CF1 R-PRF-01
Page 1 of 10
GENERAL INFORMATION
01
Project Name
Monterra Plan 4
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2015
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2013-4 (744)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.6
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft)
3650
15
Number of Zones
1
16
Slab Area (ft2)
3650
17
Number of Stories
1
18
Addition Cond. Floor Area
N/A
19
Natural Gas Available
Yes
20
Addition Slab Area (ft2)
N/A
21
Glazing Percentage (%)
19.0%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
My 0� �C���Tq
BUILDING& SAPETY DEPT
VED
FOR CONST CTION
DATEJ Z JLY
Registration Number: 214-N0048135B-000000000-0000 Registration Date/Time: 2015-11-04 16:42:22 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 16:33:20
. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: Monterra Plan 4
Calculation Description: Title 24 Analysis
Calculation Dat&Time: 16:32, Wed, Nov04, 2015
Input File Name: Monterra-Plan 4-Helton Deford-13.xml
Page 2 of 10
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDVtft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.17
0.99
0.18
15.4%
Space Cooling
95.31
79.48
15.83
16.6%
IAQ Ventilation
0.81
0.81
0.00
0.0%
Water Heating
7.03
6.80
0.23
3.3%
PV Credit
----
0.00
0.00
----
North Facing Compliance Total
104.32
88.08
16.24
15.6%
Space Heating
1.17
1.27
-0.10
-8.5%
Space Cooling
95.31
86.36
8.95
9.4%
IAQ Ventilation
0.81
0.81
0.00
0.0%
Water Heating
7.03
6.80
0.23
3.3%
PV Credit
----
0.00
0.00
----
East Facing Compliance Total
104.32
95.24
9.08
8.7%
Space Heating
1.17
1.26
-0.09
-7.7%
Space Cooling
95.31
77.89
17.42
18.3%
IAQ Ventilation
0.81
0.81
0.00
0.0%
Water Heating
7.03
6.80
0.23
3.3%
PV Credit
=--
0.00
0.00
----
South Facing Compliance Total
104.32
86.76
17.56
16.8%
Space Heating
1.17
1.15
0.02
1.7%
Space Cooling
95.31
85.29
10.02
10.5%
IAQ Ventilation
0.81
0.81
0.00
0.0%
Water Heating
7.03
6.80
0.23
3.3%
PV Credit
----
0.00
0.00
----
West Facing Compliance Total
104.32
94.05
10.27
9.8%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins err 1 iI JE . { A �
`J�G - ° "11V 1)
��� SAFETY pEpT
FOR CO,ti°� rq ��C�
DATF ®N
Registration Number: 214-N0048135B-000000000-0000 Registration Date/Time: 2015-11-04 16:42:22 --At rovider: CaICERTS inc.
d a : 15-11-04 16:33:20
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report a Ee
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:32, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 4-Helton Deford-13.xml
CF1 R-PRF-01
Page 3 of 10
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
- IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Ducts located entirely In conditioned space
Domestic Hot Water System Verifications:
• —None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on -site renewable energy system. -
Reference Energy Use '': '"
Energy Design Rating
Margin
Percent Improvement
Total Energy (kTDV/f2-yr)•
143.85
134.77
9.08
6.3%
includes calculated Appliances and Miscellaneous Energy,Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Monterra Plan 4
3650
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(tt2)
Avg. el tv1
H Igt77-
a rat at Jqg System
—WateHeating System 2
Plan 4
Conditioned
HVAC 1, 2 & 31
3650
9 BUILI
r\v T . F ' SryP LlI
1
` r UI--
FOR PROVED
TRUCTION
Registration Number: 214-N0048135B-000000000-0000 Registration Date/Time: 2015-11-04 16:42:22 CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 16:33:20
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation DatelTime: 16:32, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 4-Helton Deford-13.xml
CF1 R-PRF-01
Page 4 of 10
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (W)
Window & Door Area (ft)
Tilt (deg)
N Wall
Plan 4
R-21 Wall (W.19.2x6.16)
0
Front
860
244.019
90
E Wall
Plan 4
R-21 Wall (W.19.2x6.16)
90
Left
730
73
90
S Wall
Plan 4
R-21 Wall (W.19.2x6.16)
180
Back
860
282.5
90
W Wall
Plan 4
R-21 Wall (W.19.2x6.16)
270
Right
750
93.5
90
R-38 Roof
Plan 4
R-38 Roof(R.38.2x14.16)
3650
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Plan 4
Attic RoofPlan 4
Ventilated
4.36764
0.1
0.85
No
No
CITY OF: LA
BUILDING & QUI NTA
o SAFETY
PPR��� DEBT
TRUCTI
ON
DATE
Registration Number: 214-N0048135B-000000000-0000 Registration Date/Time: 2015-11-0416:42:22 �1E1t5-Rreuide�� 1 CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-11-04 16:33:20
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4
Calculation Description: Title 24 Analysis
Calculation Date/Time: 16:32, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 4-Helton Deford-13.xml
CF1 R-PRF-01
Page 5 of 10
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multipll
er
Area
(ft2)
IJ-factor
SHGC
Exterior Shading
1.5X8 F
Window
N Wall (Front-0)
1.3
8.0
1.154
12.0
0.32
0.24
Insect Screen (default)
3.5X8 FD
Window
N Wall (Front-0)
3.5
8.0
1
28.0
0.32
0.24
Insect Screen (default)
1.5X8 F 2
Window
N Wall (Front-0)
1.3
8.0
1.154
12.0
0.32
0.24
Insect Screen (default)
16X8 PD
Window
N Wall (Front-0)
18.0
8.0
0.889
128.0
0.32
0.24
Insect Screen (default)
8X8 PD
Window
N Wall (Front-0)
----
----
1
64.0
0.32
0.24
Insect Screen (default)
2X5 SH
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 SH 2
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
3X5.5 SH
Window
E Wall (Left-90)
----
----
1
16.5
0.32
0.24
Insect Screen (default)
3X5.5 SH 2
Window
E Wall (Left-90)
----
----
1
16.5
0.32
0.24
Insect Screen (default)
2X5 F
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 2
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
6X8 FD
Window
S Wall (Back-180); ;
--
_ ----
1
48.0
0.32
0.24
Insect Screen (default)
5X4.5 SL
Window
S Wall (Back-180)
---
1
22.5
0.32
0.24
Insect Screen (default)
16X8 PD 2
Window
S Wall (Back-180)_
16.0
8.0
1
128.0
0.32
0.24
Insect Screen (default)
6X8 FD 2
Window
S Wall (Back-180)`
-
t
48.0
0.32
0.24
Insect Screen (default)
6X6 SL
Window
S Wall (Back-180)
----
----
1
36.0
0.32
0.24
Insect Screen (default)
2X5 F 3
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 4
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5.5SH
Window
W Wall (Right-270)
----
----
1
11.0
0.32
0.24
Insect Screen (default)
5X5.5 F
Window
W Wall (Right-270)
----
----
1
27.5
0.32
0.24
Insect Screen (default)
2X5.5 SH
Window
W Wall (Right-270)
----
----
1
11.0
0.32
0.24
Insect Screen (default)
3X8 FD
Window
W Wall (Right-270)
---
----
1
24.0
0.32
0.24
Insect Screen (default)
CITY OF LA Qu,NTA
BUILDING & SAFETY D^
FORPPROV�, D PT.
CONSTRUCTION
DATE
Registration Number: 214-N0048135B-000000000-0000 Registration Date/Time: 2015-11-04 16:42:22 owdPr----___ CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 201 -11-04 16:33:20
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:32, Wed, Nov 04, 2015
CF1 R-PRF-01
Page 6 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-Helton Deford-13.xml
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DIstL
Bot Up
Depth
Top Up
Dist R
Bot Up
1.5X8 F
10
0.1
10
10
0
0
0
0
0
0
0
0
0
3.5X8 FD
10
0.1
10
10
0
0
0
0
0
0
0
0
0
1.5X8 F 2
10
0.1
10
10
0
0
0
0
0
0
0
0
0
16X8 PD
4
0.1
4
4
0
0
0
0
0
0
0 J
0
0
16X8 PD 2
4
0.1
1 4
4
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
• Cavity / Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofPlan 4
Attic Roofs
Wood Framed Ceiling
An. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R 9.1 /2x4
R-38 Roof (R.38.2x14.16)
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C:
R 38
0.025
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
• Exterior Finish: Wood
R-21 Wall (W. 1 9.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
Plan 4
430
52
None
0.8
No
Hard Surface Slab
Plan 4
3220
263
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION 6 0
P j
01
02
of BUILDING &
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envel pe Air L kage�
r-7 `C M50
Not Required
Not Required
Not R quired FOR Q0NsTPiW
Registration Number: 214-N0048135B-000000000-0000 Registration Date/Time: 2015-11-04 16:42:22
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
DATE
-F�R�rovider. CaICERTS inc.
Report Genera 1-04 16:33:20
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name: Monterra Plan 4 Calculation Datefrime: 16:32, Wed, Nov 04, 2015 Page 7 of 10
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 4-Helton Deford-13.xml
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 - 1/1
DHW
Parallel Piping
DHW Heater 1
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.62
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
-''
SPACE CONDITIONING SYSTEMS
01 02 03 041 05 06
SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name
HVAC 1, 2 & 31 Other Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1
System
HVAC - HEATING UNIT TYPES
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
ul j Y ui' L QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE -----
BY
Registration Number: 214-N0048135B-000000000-0000 Registration Date/Time: 2015-11-04 16:42:22 HERS Provider: __J CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 16:33:20
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:32, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 4-Helton Deford-13.xml
CF1 R-PRF-01
Page 8 of 10
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
12
14
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Not Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsInAll
Sealed and tested
8
Conditioned zone
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
.03 "
04 `,
05
�06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Burled
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Required
Not Required
Not Required
Not Required
---
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CF
ERS Verlflcatlon
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
[HA -AC, �r� 1,,h rfja�
HVAC FAN SYSTEMS - HERS VERIFICATION .y I
In..---
01
02
�
A t "`_03OR CP
Name
Verified Fan Watt Draw
Req u I re_d*Wbf clWcyl(WA CFM)
HVAC Fan 1-hers-fan
Required
DAT 0.58
Registration Number: 214-N0048135B-000000000-0000 Registration Date/Time: 2015-11-0416:42:22 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08252015-744 Report Generated at: 2015-11-04 16:33:20
•
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:32, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 4-Helton Deford-13.xml
CF1 R-PRF-01
Page 9 of 10
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
66.5
0.25
Default
0
Required
CITY OF LA QUIIVTA
BUILDING & SAFETY
APPROVED
FOR CONSTRUCTION
BY
Registration Registration Number: 214-N0048135B-000000000-0000 Registration Date/Time: 2015-11-04 16:42:22 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-11-04 16:33:20
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:32, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 4-Helton Deford-13.xml
CF1 R-PRF-01
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
TNV.5�
Company:
Signature Date:
Scott Design and Title 24, Inc.
2015-11-04 16:41:52
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Tim Scott
Company:
Date Signed: - -
Scott Design and Title 24, Inc.
2015-11-04 16:42:22
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no
information.
CITY ®F C��l
BUI
LDING & say NT'q
implie g' traiion�Provi � Con ty or th accuracy of the
CONSTRUCTI
ON
DATE
Registration Number: 214-N0048135B-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time
2015-11-04 16:42:22
Report Version - CF1R-08252015-744
HERS Provl CaICERTS inc.
Report Generated at: 2015-11-04 16:33:20
BUILDING ENERGY ANALYSIS REPORT
A
PROJECT:
Monterra, Plan 2
55-101 Monroe
La Quinta, CA 92253
Project Designer:
Helton, DeFord & Associates
17411 Irvine Blvd, Suite O
Tustin, CA 92780
(909) 957-4550
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
77085 Michigan Drive
Palm Desert, C.(760) 200 4T§,V OF LA QUINTA
BUILDING & SAFETY DEPT.
APP� VED
FOR CONSUCTION
DATE I2L
Job Number: '?ECEIVIED
NOV 18 2015
Date: COMM N pV 'WA
11 /4/2015 I64'41f T
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
L EnergyPro 6.7 by EnergySoft User Number. 6712 ID:
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF-1 R-PRF-01-E Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 13
Form MF-1 R Mandatory Measures Summary 14
HVAC System Heating and Cooling Loads Summary 18
Zone Load Summary 19
Room Load Summary 20
Room Heating Peak Loads 21
Room Cooling Peak Loads 22
EnergyPro 6.7 by EnergySoft Job Number: ID: User Number: 6712 1
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 10:38, Wed, Nov 04, 2015
CF1 R-PRF-01
Page 1 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-Helton Deford-13.xml
GENERAL INFORMATION
01
Project Name
Monterra Plan 2
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quints
05
Standards Version
Compliance 2015
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2013-4 (744)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.6
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
3220
15
Number of Zones
A
1
16
Slab Area (ft2)
3220
17
c#.
Number of Stories
1
18
Addition Cond. Floor Area
N/A
�19 y
Natural Gas Available
Yes
20
Addition Slab Area (ft2)
N/A
21
Glazing Percentage (%)
19.8%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance ~`
02
This building incorporates features that require field testing and/or verificafion by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown belo
r
41-
Registration Number:
CA Building Energy Efficiency Stari`da'rds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFiR-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:39:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 10:38, Wed, Nov 04, 2015
CF1 R-PRF-01
r I.
Page 2 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-Helton Deford-13.xmi
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.52
1.73
-0.21
-13.8%
Space Cooling
101.93
92.59
9.34
9.2%
IAQ Ventilation
0.86
0.86
0.00
0.0%
Water Heating
7.97
7.71
0.26
3.3%
PV Credit
----
0.00
0.00
----
North Facing Compliance Total
112.28
102.89
9.39
8.4%
Space Heating
1.52
(� 63
-0.11
-7.2%
Space Cooling
101.93
fi09.21
2.72
2.7%
IAQ Ventilation
0.86
�3`;a 0.86
0.00
0.0%
9
Water Heating
7.97
7.71
0.26
3.3%
PV Credit
----
0.00
0.00
----
East Facing Compliance Total
112.28
109.41
2.87
2.6%
�i
Space Heating
1.52
1.53
-0.01
-0.7%
Space Cooling
101.93
92.90
9.03
8.9%
IAQ Ventilation
0.86
` 0.86
0.00
0.0%
Water Heating
7.97 r
7.71
0.26
3.3%
PV Credit
---- $
0.00
0.00
----
South Facing Compliance Total
112.28 '1 "
103.00
9.28
8.3%
Space Heating
1.51��
1.59
-0.07
-4.6%
Space Cooling
*1:0193
98.05
3.88
3.8%
IAQ Ventilation
<-�%0.86
0.86
0.00
0.0%
Water Heating
7.97
7.71
0.26
3.3%
PV Credit
- r:''
0.00
0.00
-
West Facing Compliance Total
112.28
108.21
4.07
3.6%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition=for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
�1
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:39:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 10:38, Wed, Nov 04, 2015
CF1 R-PRF-01
f I.
Page 3 of 10
Calculation Description: Title 24 Analysis
HERS FEATURE SUMMARY
Input File Name: Monterra-Plan 2-Helton Deford-13.xmi
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Ducts located entirely in conditioned space
Domestic Hot Water System Verifications:
..None --
ENERGY DESIGN RATING :<
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domest 8.6ppliances and consumer electronics) and accounting for the annual TDV energy offset by an
,,.
on -site renewable energy system.
N
Reference Energy Use -
Energy Design Rating
Margin
Percent Improvement
Total Energy (kTDV/f2-yr)•
153.14 "'
150.27
2.87
1.9%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION fit'
01
02
03 ";
04
05
06
07
Number.ofDwelling
Number of Ventilation
Number of Water
Project Name
Conditioned Floor Area (ft2)°;Units
Number of Bedrooms
Number of Zones
Cooling Systems
Heating Systems
Monterra Plan 2
3220
' 1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Floor Area
Avg. Ceiling
Zone Name
Zone Type
HVAC System Name
(ff)
Height
Water Heating System 1
Water Heating System 2
Plan 2
Conditionedr'r4'
HVAC 1 & 21
3220
9
DHW Sys i
Y '
1
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:39:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2
Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:38, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 2-Helton Deford-13.xml
CF1 R-PRF-01
i r
Page 4 of 10
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door Area (ft)
Tllt (deg)
N Wall
Plan 2
R-21 Wall (W.19.2x6.16)
0
Front
740
217.60399999999998
90
E Wall
Plan 2
R-21 Wall (W19.2x6.16)
90
Left
880
69
90
S Wall
Plan 2
R-21 Wall (W19.2x6.16)
180
Back
740
292
90
W Wall
Plan 2
R-21 Wall (W19.2x6.16)
270
Right
880
80
90
R-38 Roof
Plan 2
R-38 Roof(R.38.2x14.16)
3220
ATTIC
01
02
03
04 ' ;.
05
06
07
08
Name
Construction
Type
Roof -Rise
: w.-
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Plan 2
Attic RoofPlan 2
Ventilated
4:36764
0.1
0.85
No
No
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:39:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2
Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:38, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 2-Helton Deford-13.xml
CF1 R-PRF-01
�.
Page 5 of 10
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multipll
er
Area
(ft2)
U-factor
SHGC
Exterior Shading
2X4.5 F
Window
N Wall (Front-0)
2.0
8.0
0.562
9.0
0.32
0.24
Insect Screen (default)
1.5X8 F
Window
N Wall (Front-0)
3.5
8.0
0.429
12.0
0.32
0.24
Insect Screen (default)
3.5X8 FD
Window
N Wall (Front-0)
2.0
8.0
1.75
28.0
0.32
0.24
Insect Screen (default)
1.5X8 F 2
Window
N Wall (Front-0)
----
----
1
12.0
0.32
0.24
Insect Screen (default)
2.5X6F
Window
N Wall (Front-0)
---- -
-
1
45.0
0.32
0.24
Insect Screen (default)
2.5X6F 2
Window
N Wall (Front-0)
----'"
- -
1
45.0
0.32
0.24
Insect Screen (default)
2.5X6F 3
Window
N Wall (Front-0)
----
1
45.0
0.32
0.24
Insect Screen (default)
2X5 F
Window
E Wall (Left-90)
> --
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 2
Window
E Wall Left-90`�
( )
;��,, ----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X4SH
Window
E Wall Left-90
( )
9,"'
. �= ----
----
1
8.0
0.32
0.24
Insect Screen (default)
3X5.5 SH
Window
E Wall (Left-90)
----
----
1
16.5
0.32
0.24
Insect Screen (default)
6X5.5 SH
Window
E Wall (Left-90) '
,F,sT
----
----
1
16.5
0.32
0.24
Insect Screen (default)
2X4 SH 2
Window
E Wall (Left-90) c ti'
----
----
1
8.0
0.32
0.24
Insect Screen (default)
6X8 FD
Window
S Wall (Back-180) �
----
----
1
48.0
0.32
0.24
Insect Screen (default)
20X8 Pd
Window
S Wall (Back-180)
20.0
8.0
1
160.0
0.32
0.24
Insect Screen (default)
6X8 FD 2
Window
S Wall (Back-180) (`
----
----
1
48.0
0.32
0.24
Insect Screen (default)
6X6 SL
Window
S Wall (Back-10)'
----
---
1
36.0
0.32
0.24
Insect Screen (default)
2X5 F 3
Window
W Wall (RigFi(:,270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 4
Window
W Wall (Right=270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
6X6 SL 2
Window
W Wall, (Right-270)
. .,
----
1
36.0
0.32
0.24
Insect Screen (default)
3X8 FD
Window
W :Wall (Right-270)
----
----
1
24.0
0.32
0.24
Insect Screen (default)
r.
DOORS
01$
02
03
04
Name9*
Side of Building
Area (ft2)
U-factor
Door`'
N Wall
21.6
0.50
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:39:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 10:38, Wed, Nov 04, 2015
CF1R-PRF-01 r
Page 6 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-Helton Deford-13.xml
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
sot Up
Depth
Top Up
Dist R
Bot Up
2X4.5 F
0
0
0
0
0
0
0
0
0
0
0
0
0
1.5X8 F
10
0.1
10
10
0
0
0
0
0
0
0
0
0
3.5X8 FD
10
0.1
10
10
0
0
0
0
0
0
0
0
0
20X8 Pd
14
0.1
14
14
0
0' ,"
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
'f�:
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing ;",
R-value
U-value
Assembly Layers
41Ftoof
Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofPlan 2
Attic Roofs
Wood Framed Ceiling
it O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof (R.38.2x14.16)
attic)
Wood Framed Ceiling
F 2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
.>
Inside Finish: Gypsum Board
Cavity/Frame: R-21 /2x6
=`
Exterior Finish: Wood
R-21 Wall (W.19.2x6.16)
Exterior Walls
Wood Framed Wall"
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
SLAB FLOORS
01
02 €'r y
03
04
05
06
07
Name
Zone e °
2 (ft Area
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
Plan 2
481
56
None
0.8
No
Hard Surface Slab
Plan 2 t,;v
2739
266
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
•:
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required''
Not Required
Not Required
---
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:39:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 10:38, Wed, Nov 04, 2015
CF1 R-PRF-01 E
Page 7 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-Helton Deford-13.xml
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 - 1/1
DHW
Parallel Piping
DHW Heater 1
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Tank Exterior
Tank Volume
Energy Factor or
Insulation
Standby Loss
Name
Heater Element Type
Tank Type
(gal)
Efficiency
Input Rating
R-value
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50 A
1 0.62
40000-Eitu/hr
0
0
WATER HEATING - HERS VERIFICATION r`2
01
02
03 J
04
05
06
07
Recirculation
Central DHW
Name
Pipe Insulation
Parallel Piping, ,
Compact Distribution
Point -of Use
Control
Distribution
DHW Sys 1 - 1/1
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC 1 & 21
Other Heating and Cooii"ng `
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES ^"
01 �.
02
03
Name , a,
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:39:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 10:38, Wed, Nov 04, 2015
CF1 R-PRF-01 [
Page 8 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-Helton Deford-13.xml
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
11
13
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Verified Refrigerant
Name
Verified Airflow
Airflow Target,I
Verified EER
Verified SEER
Charge
Cooling Component 1-hers-cool
Required
350 '
' Not Required
Not Required
Required
HVAC - DISTRIBUTION SYSTEMS A
01
02
03
04
05
06
07
Name
Type
Duct Leakage ,
`%°Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctslnAll
Sealed and tested.,;
8
Conditioned zone
None
Air Distribution System
ell
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03 h"�
04
05
06
07
08
Duct Leakage
Duct Leakage
Verified Duct
Verified Duct
Burled
Deeply Buried
Low -leakage
Name
Verification
Tar
.,.,get �get(%)
Location
Design
Ducts
Ducts
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Required
Not Required
Not Required
Not Required
---
HVAC -FAN SYSTEMS`
01
+-` 02
03
04
Name
: - Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
`` Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION "
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:39:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 10:38, Wed, Nov 04, 2015
CF1 R-?RF-01 u
Page 9 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-Helton Deford-13.xml
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
62.2
0.25
Default
0
Required
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFiR-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:39:38
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2
Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:38, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 2-Helton Deford-13.xml
CF1 R-PRF-01
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc,
11 /4/2015
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/Stat i :
Palm Desert, CA 92211
Phone:
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California: 3
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility forthe building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate 9f,, liance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations..•-
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency', approval with this building permit application.
Responsible Designer Name: g"
Responsible Designer Signature:
Jim Deford�
Company:
Date Signed:
Helton, DeFord & Associates A'
Address: N '
License:
17411 Irvine Blvd, Suite O
City/State/Zip: .; �,
Phone:
Tustin, CA 92780�
(909) 957-4550
"
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 10:39:38
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Monterra, Plan 2
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111412015
Project Address
55-101 Monroe La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,220
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features
Status
Roof Wood Framed Attic
R 38 3,220
New
Wall Wood Framed
R 21 2, 581
New
Door Opaque Door
-
no insulation 22
New
Slab Unheated Slab -on -Grade
- no insulation 3,220 Perim = 322'
New
FENESTRATION
Orientation Area(ft2)
I Total Area: 637 Glazing Percentage: 19.8 New/Altered Average U-Factor:
U-Fac SHGC Overhang Sidefins Exterior Shades
0.32
Status
Front (N) 156.0
0.320
0.24 none none Bug Screen
New
Front (N) 40.0
0.320
0.24 10.0 none Bug Screen
New
Left (E) 69.0
0.320
0.24 none none Bug Screen
New
Rear (S) 132.0
0.320
0.24 none none Bug Screen
New
Rear (S) 160.0
0.320
0.24 14.0 none Bug Screen
New
Right (Kq 80.0
0.320
0.24 none none Bug Screen
New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling Min. Eff Thermostat Status
2 Central Furnace
80 % AFUE
Split Air Conditioner 13.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
HVAC 1 & 2 Ducted
Ducted Conditioned 8.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
1 Small Storage Gas
50
0.62 Parallel Piping
New
EnemvPro 6.7 by EnergySoft User Number. 6712
RunCode: 2015-11-04T10:50:06 ID:
Page 13 of 24
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance annroach used. Exceptions may anDly. Review the resaective code section for more information.
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ I10.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration that meets the requirements of § 10-111(a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(1):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CF1R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U-factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ 150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R-value.
§ 150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U-
factor).
§ 150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U-factor.
In Climate Zones 14 and 16 a Class R vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§ 150.0(g)l:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class H
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class 11 vapor retarder shall be placed over the earth floor of
§ 150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
l 50.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8( ).
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U-factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)1B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§ 150.0(e)1C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §I10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§150.0(h)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in§150.Oh2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§ 150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150.00)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§ 150.00)2C:
Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating
systems or hot water systems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ 150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class H vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class H vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category ID or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§I50.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of §I10.3(c)5.
§ 150.0(n)3:
Solar water -hearing systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANS11SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, L1L 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross -sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ I50.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R-value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ 150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§ 150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ 150.0(m)l 1:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§ 150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§ 150.0(m)13:
space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy < 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ 150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of > 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)1A:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110A(a):
Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operatinr, instructions; and shall not use electric resistance heating.
-2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous bunting pilot light.
§ 150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§150.0(k)1A:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§ 150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)1 C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting per electrical box.
§150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k) IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ 150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in § 150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it
§150.0(k)2H:
functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements
of §130.5; and all other requirements in § 150.0(k)2.
§ 150.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ 150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ l 50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
--2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
'
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ 150.0(k)9B:
following requirements:
i. Shall comply with § 150.0(k)9A; or
ii. Shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)l 0:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ 150.0(k)l l:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9, § 130.0, § 130.1, § 130.4, § 140.6, and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ 150.0(k)12B:
i. Comply with the applicable requirements in § 110.9, § 130.0, § 130.1, § 140.6 and § 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10(b) through § 110.10(e).
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)l:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Monterra, Plan 2
Date
11/4/2015
System Name
HVAC 1 & 2
Floor Area
3,220
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 1,758
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
35,531
4,599
882
39,024
Total Output (Btuh)
178,000
0
Output (Btuhlsgft)
55.3
514
464
Cooling System
0
0
Output per System
57,500
0
0
0
0
Total Output (Btuh)
115,000
0
4,599
0
Total Output (Tons)
9•6
514
464
Total Output (Btuh/sgft)
35.7
Total Output (s ft/Ton)
336.0
1 36,560
39,952
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow (cfm)
4,000
Carrier 24ACA460/58CVXI10
81,892
9,893
178,000
Airflow (cfmisgft)
1.24
Airflow (cfm/Ton)
417.4
Outside Air (%)
0•0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
81,892
9,893
178,000
Jan 1 AM
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions .
F Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS (Airstream
Temperatures at Time of Heating' Peak)
26 OF 72 OF
Outside Air
0 cfm Supply Fan
4,000 cfm
72 OF
72 OF 114 OF
�• • •� ••-
Heating Coil
ee
- • -
114 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112/78°F 70/58°F 70/58°F 51150°F
sl
Outside Air
0 cfm Supply Fan Cooling Coil
4,000 cfm
70158 OF ( [[
W.
51 / 50 OF
48.8 % V
Rt?OM
I
70158 OF
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-11-04T10:50:06
ID: Page 18 of 24
ZONE LOAD SUMMARY
Project Name
Monterra, Plan 2
Date
111412015
System Name
HVAC 1 & 2
Floor Area
3,220
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING
PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
Sensible
Plan 2
1.0
0
Aug 3 PM
1,758
35,531
4,599
882
39,024
TOTALS
0
0
0
0
Aug 3 PM
35,531
4,599
39,024
(BLOCK LOAD)
EnergyPro 6.7 by EnergySoR User Number- 6712 RunCode: 2015-11-04T10:50:06 ID: Page 19 of 24
I ROOM LOAD SUMMARY I
Monterra, Plan 2 111412015
System Name Floor Area
HVAC 1 & 2 3,220
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK
Zone Name Room Name Mult. CFM I Sensible I Latent CFM I Sensible I Latent I CFM I Sensible
Plan 2 Plan 2 1 1 1,7581 35,5311 4, 599 1,7581 35,5311 4,5991 8821 39,024
PAGE TOTAL
TOTAL*
1,758
35,531
4,599,
882
39,024
1,7581
35,5311
4,5991
882
39,024
Total includes ventilation load for zonal systems.
EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-11-04T10:50:06 ID: Page 20 of 24
ROOM HEATING PEAK LOADS
Project Name
Monterra, Plan 2
Date
111412015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Plan 2
Floor Area 3,220.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof(R.38.2x 14.16)
3,220.0
0.0260
46
3,851
R-21 Wall (W.19.2x6.16)
2, 581.4
0.0690
46
8,193
Milgard Low-E Vinyl
637.0
0.3200
46
9,377
Wood Door
21.6
0.5000
46
497
Slab -On -Grade
perim = 322.0
0.7300
46
10,813
Items shown with an asterisk (*) denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 3,220 X
Area
another room
9.00 X 0.266
Height ACH
Page Total
/ 60 ] X
AT
32,731
= 6,293
TOTAL HOURLY HEAT LOSS FOR ROOM 39,024
EnergyPro 6.7 by EnergySoft User Number- 6712 RunCode: 2015-11-04T10:50:06 ID: Page 21 of 24
I RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Monterra, Plan 2 1 111412015
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
Indoor Dry Bulb Tern
Opaque Surfaces
R-38 Roof(R.38.2x 14.16)
R-21 Wall (W.19.2x6.16)
Wood Door
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
Orientation
(IM
(N)
(N)
(E)
(S)
(M
Plan 2 Outdoor Dry Bulb Temperature
3,220.0 ft2 Outdoor Wet Bulb Temperature
70 OF Outdoor Dailv Range:
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
3,220.0
0.0260
56.0
522.4
0.0690
23.0
21.6
0.5000
23.0
811.0
0.0690
33.0
448.0
0.0690
26.0
800.0
0.0690
33.0
Page Total
Items shown with an asterisk (*) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
2X4.5 F
1.5X8 F
3.5X8 FD
1.5X8 F
2.5X6F
2.5X6F
2.5X6F
2X5 F
2X5 F
Orientation
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(E)
(E)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
15.3
9.0
15.3
0.0
15.3
12.0
15.3
0.0
15.3
28.0
15.3
0.0
15.3
12.0
15.3
0.0
15.3
45.0
15.3
0.0
15.3
45.0
15.3
0.0
15.3
45.0
15.3
0.0
15.3
10.0
29.6
0.0
15.3
10.0
29.6
Page Total
112 OF
78 OF
34 OF
Btu/hr
4,688
829
248
1,847
804
1,822
10,238
Btu/hr
138
184
429
184
689
689
689
296
296
3, 591
Internal Gain Btu/hr
Occupants 9 7 Occupants X 245 Btuh/occ. = Z,
Equipment 3,220 Floor Area X 0.50 w/sgft = 5,�
Infiltration: 1.064 X 0.94 X 132.81 X 42 =
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 35,531
Latent Gain Btu/hr
Occupants 9 7 Occupants X 155 Btuh/occ. = 1,497
Infiltration: 4,771 X 0.94 X 132.81 X 0.00523 = 3,102
Air Sensible CFM ELA AW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,497
EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-11-04T10:50:06 ID: Page 22 of 24
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Monterra, Plan 2 11/4/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Plan 2
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,220.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
70 OF 1
Outdoor Daily Range:
34 OF
Surfaces
Orientation
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
Page Total
Items shown with an asterisk (") denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
2X4 SH
3X5.5 SH
6X5.5 SH
2X4 SH
6X8 FD
20X8 Pd
6X8 FD
6X6 SL
2X5 F
Orientation
(E)
(E)
(E)
(E)
(S)
(S)
(S)
(S)
(W)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
0.0
15.3
8.0
29.6
0.0
15.3
16.5
29.6
0.0
15.3
16.5
29.6
0.0
15.3
8.0
29.6
0.0
15.3
48.0
15.4
160.0
15.3
0.0
15.4
0.0
15.3
48.0
15.4
0.0
15.3
36.0
15.4
0.0
15.3
10.0
29.6
Page Total
Btu/hr
Btu/hr
236
488
488
236
737
2,449
737
553
6,
Internal Gain Btu/hr
Occupants 9.7 Occupants X 245 Btuh/occ.
Equipment 3,220 Floor Area X 0.50 W/sgft = 5,
Infiltration: 1.064 X 0.94 X 132.81 X 42 =
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 35,5311
Latent Gain Btu/hr
Occupants 9 7 Occupants X 155 Btuh/occ. _
Infiltration: 4,771 X 0.94 X 132.81 X 0.00523 =
Air Sensible CFM ELA AW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1.4971
I EnergyPro 6.7 by EnergySoft User Number- 6712 RunCode: 2015-11-04T10:50:06 ID: Page 23 of 24 1
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Monterra, Plan 2
111412015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Plan 2
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,220.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (*)
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
2X5 F
(1/10 0.0 X 15.3 +
10.0
X 29.6
= 296
6X6 SL
(WJ 0.0 X 15.3 +
36.0
X 29.6
= 1,064
3X8 FD
(IM 0.0 X 15.3 +
24.0
X 29.6
= 709
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +
X
=
Page Total
2,069
Internal Gain
Btu/hr
Occupants
9 7 Occupants X 245
Btuh/occ.
=
LA
Equipment
3,220 Floor Area X 0.50
w/sgft
=
Infiltration: 1.064
X 0.94 X 132.81 X 42 =
5,552
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
35,531
Latent Gain
Btu/hr
Occupants :719
7 Occupants X 155
Btuh/occ.
=
1,497
Infiltration: 4, 771
X 0.94 X 132.81 X 0.00523 =
3,102
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,497
EnergyPro 6.7 by EnergySoft
User Number: 6712 RunCode: 2015-11-04T10:50:06 ID:
Page 24 of 24
'CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation DatelTime: 10:38, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 2-Helton Deford-13.xml
CF1 R-PRF-01
Page 1 of 10
GENERAL INFORMATION
01
Project Name
Monterra Plan 2
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2015
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2013-4 (744)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.6
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
3220
15
Number of Zones
1
16
Slab Area (ft)
3220
17
Number of Stories
1
18
Addition Cond. Floor Area
N/A
19
Natural Gas Available
Yes
20
Addition Slab Area (ft2)
1 N/A
21
Glazing Percentage (%)
19.8%
COMPLIANCE RESULTS %r
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
C/r �/ ®LJ�14 /NG & AQul/T
F q
O�S
��'O ET y KEPT
o coC
UC��
ArE 1z � f� OON
eY I
Registration Number: 214-NO04761OB-000000000-0000 Registration Date/Time: 2015-11-04 11:30:36 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 10:39:46
'CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2
-Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:38, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 2-Helton Deford-13.xml
CF1 R-PRF-01
Page 2 of 10
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.52
1.73
-0.21
-13.8%
Space Cooling
101.93
92.59
9.34
9.2%
IAQ Ventilation
0.86
0.86
0.00
0.0%
Water Heating
7.97
7.71
0.26
3.3%
PV Credit
----
0.00
0.00
----
North Facing Compliance Total
112.28
102.89
9.39
8.4%
Space Heating
1.52
1.63
-0.11
-7.2%
Space Cooling
101.93
99.21
2.72
2.7%
IAQ Ventilation
0.86
0.86
0.00
0.0%
Water Heating
7.97
7.71
0.26
3.3%
PV Credit
----
0.00
0.00
----
East Facing Compliance Total
112.28
109.41
2.87
2.6%
Space Heating
1.52
1.53
-0.01
-0.7%
Space Cooling
101.93'
92.90
9.03
8.9%
IAQ Ventilation
0.86
0.86
0.00
0.0%
Water Heating
7.97
7:71
0.26
3.3%
PV Credit
-
0.00
0.00
--
South Facing Compliance Total
11128
103.00
9.28
8.3%
Space Heating
1.52
1.59
-0.07
-4.6%
Space Cooling
101.93
98.05
3.88
3.8%
IAQ Ventilation
0.86
0.86
0.00
0.0%
Water Heating
7.97
7.71
0.26
3.3%
PV Credit
----
0.00
0.00
----
West Facing Compliance Total
112.28
108.21
4.07
3.6%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. I Clr 7-V 1
- Window overhangs and/or fins / Dr ... A eN
Registration Number: 214-N0047610B-000000000-0000 Registration Date/Time: 2015-11-04 11:30:36
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
OR D �®r>IST/�UC arF N
�---may
Report Ge
CaICERTS inc.
10:39:46
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Datelrime: 10:38, Wed, Nov 04, 2015
-Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 2-Helton Deford-13.xml
HERS FEATURE SUMMARY
CF1 R-PRF-01
Page 3 of 10
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Ducts located entirely In conditioned space
Domestic Hot Water System Verifications:
• -- None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on -site renewable energy system.
Reference Energy Use
Energy Design Rating
Margin
Percent Improvement
Total Energy (kTDV/f2-yr)•
rr 153.14,
150.27
2.87
1.9%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION-
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Monterra Plan 2
3220
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Gelling
Height
�N a1h r', enting-Sy tem
Wate_ Heating System 2
Plan 2
Conditioned
HVAC 1 & 21
3220
9
SUR 19PAVys
UI .lT
Registration Number: 214-NO04761OB-000000000-0000 Registration Date/Time: 2015-11-0411:30:36
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
I �i� ETy®
ED PT.
OR COI°VSTRUCTIp�
SATE
By
HERS Provi e . CaICERTS inc.
Report Generated at: 2015-11-0410:39:46
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 10:38, Wed, Nov 04, 2015
-Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 2-Helton Deford-13.xml
CF1 R-PRF-01
Page 4 of 10
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
N Wall
Plan 2
R-21 Wall (W.19.2x6.16)
0
Front
740
217.60399999999998
90
E Wall
Plan 2
R-21 Wall (W.19.2x6.16)
90
Left
880
69
90
S Wall
Plan 2
R-21 Wall (W.19.2x6.16)
180
Back
740
292
90
W Wall
Plan 2
R-21 Wall (W.19.2x6.16)
270
Right
880
80
90
R-38 Roof
Plan 2
R-38 Roof (R.38.2x14.16)
3220
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Plan 2
Attic RoofPlan 2
Ventilated
4.36764
0.1
0.85
No
No
�3tj/gyp/NG � f
'CoR CO�SrR v i
o
ATF /ON
Registration Number: 214-NO04761OB-000000000-0000 Registration Date/Time: 2015-11-04 11:30:36
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08252015-744
HERS Provider: ------/ CaICERTS inc.
Report Generated at: 2015-11-04 10:39:46
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2
Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:38, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 2-Helton Deford-13.xml
CF1 R-PRF-01
Page 5 of 10
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multipll
er
Area
(ftz)
U-factor
SHGC
Exterior Shading
2X4.5 F
Window
N Wall (Front-0)
2.0
8.0
0.562
9.0
0.32
0.24
Insect Screen (default)
1.5X8 F
Window
N Wall (Front-0)
3.5
8.0
0.429
12.0
0.32
0.24
Insect Screen (default)
3.5X8 FD
Window
N Wall (Front-0)
2.0
8.0
1.75
28.0
0.32
0.24
Insect Screen (default)
1.5X8 F 2
Window
N Wall (Front-0)
----
----
1
12.0
0.32
0.24
Insect Screen (default)
2.5X6F
Window
N Wall (Front-0)
----
----
1
45.0
0.32
0.24
Insect Screen (default)
2.5X6F 2
Window
N Wall (Front-0)
----
----
1
45.0
0.32
0.24
Insect Screen (default)
2.5X6F 3
Window
N Wall (Front-0)
----
----
1
45.0
0.32
0.24
Insect Screen (default)
2X5 F
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 2
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X4 SH
Window
E Wall (Left-90)
----
----
1
8.0
0.32
0.24
Insect Screen (default)
3X5.5 SH
Window
E Wail (Left-90)
----
----
1
16.5
0.32
0.24
Insect Screen (default)
6X5.5 SH
Window
E Wall (Left-90)
--
----
1
16.5
0.32
0.24
Insect Screen (default)
2X4 SH 2
Window
E Wall (Left-90)
--
1 -
8.0
0.32
0.24
Insect Screen (default)
6X8 FD
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
20X8 Pd
Window
S Wall (Back-180) "
20.0
8.0
1
160.0
0.32
0.24
Insect Screen (default)
6X8 FD 2
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
6X6 SL
Window
S Wall (Back-180)
----
----
1
36.0
0.32
0.24
Insect Screen (default)
2X5 F 3
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 4
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
6X6 SL 2
Window
W Wall (Right-270)
----
-
1
36.0
0.32
0.24
Insect Screen (default)
3X8 FD
Window
W Wall (Right-270)
----
----
1
24.0
0.32
0.24
Insect Screen (default)
DOORS
01
02
fr 1 V 0 �
04
Name
Side of Building
.# ,-
Bull AreaaV(1t2)
ff � u-f ctor
Door
N Wall
2�1 ^ GAF
Y n 7-
Registration Number: 214-NO04761OB-000000000-0000 Registration Date/Time: 2015-11-0411:30:36
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
1.
FOR Cp S R CED
DATE ON
HERS Provider: CalCERTS inc.
Report Generated at: 2015-11-04 10:39:46
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2
Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:38, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 2-Helton Deford-13.xml
CF1 R-PRF-01
Page 6 of 10
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DIstL
Bot Up
Depth
Top Up
Dist R
Bot Up
2X4.5 F
0
0
0
0
0
0
0
0
0
0
0
0
0
1.5X8 F
10
0.1
10
10
0
0
0
0
0
0
0
0
0
3.5X8 FD
10
0.1
10
10
0
0
0
0
0
0
0
1 0
0
20X8 Pd
14
0.1
14
14
0
0
0
1 0
0
0
0
1 0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
• Cavity / Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofPlan 2
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof(R.38.2x14.16)
attic)
Wood Framed Ceiling
2x4 0-16 in. O.C.
R 38-
0.025,
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 /2x6
• Exterior Finish: Wood
R-21 Wall (W.19.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
Plan 2
481
56
None
0.8
No
Hard Surface Slab
Plan 2
2739
266
one
0.8
No
Lw7NwAFAy� —�
BUILDING ENVELOPE - HERS VERIFICATION U t,ip� N
BiiiL . ,� � o ��
01
02
03
6 r�H'-': 'YO�DE
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakag
° U VFOR FI A
Not Required
Not Required
Not Required
1 CTION
Registration Number: 214-N0047610B-000000000-0000 Registration Date/Time: 2015-11-04 11:30:36
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
SATE
�� BY
HERS Provider: aICERTS inc.
Report Generated at: 2015-11-04 10:39:46
• CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: Monterra Plan 2
- Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:38, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 2-Helton Deford-13.xml
Page 7 of 10
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 - 1/1
DHW
Parallel Piping
DHW Heater 1
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.62
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
-
---
SPACE CONDITIONING SYSTEMS
01
02
03 `,
04:
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC 1 & 21
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01
02
03
Name
Type
Efficlency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
4 1 Y OF I A Blot- I
13UILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE BY
Registration Number: 214-NO04761OB-000000000-0000 Registration Date/Time: 2015-11-04 11:30:36 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 10:39:46
• CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2
Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:38, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 2-Helton Deford-13.xml
CF1 R-PRF-01
Page 8 of 10
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
11
13
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Not Required
Not Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsInAll
Sealed and tested
8
Conditioned zone
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
O6
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Burled
Ducts
Deeply Burled
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Required
Not Required
Not Required
Not Required
---
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58 /
AE-F-an 1Ahers-_ f_ a_an
W WAri!t!I01VE_6 �
HVAC FAN SYSTEMS - HERS VERIFICATION bUILDING & ,S F=FTv ' r-,
01
02
�A(-)93 C7v`
Name
Verified Fan Watt Draw
F C-AP i eff�n fflclep y atts/CFIN)
Al
HVAC Fan 1-hers-fan
Required
0.58
Registration Number: 214-NO04761OB-000000000-0000 Registration Date/Time: 2015-11-04 11:30:36
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider: CaICERTS inc.
Report Generated at: 2015-11-04 10:39:46
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 10:38, Wed, Nov 04, 2015
- Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 2-Helton Deford-13.xml
CF1 R-PRF-01
Page 9 of 10
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
62.2
0.25
Default
0
Required
CITY OF 1.4 C NTA
BUILDING & SAFETY DEPT.
APPOVE
FOR CONSTRUCTION
Dar
Registration Number: 214-NO04761OB-000000000-0000 Registration Date/Time: 2015-11-04 11:30:36 6ERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08252015-744 Report Generated at: 2015-11-04 10:39:46
CF1 R-PRF-01
'CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation DatelTime: 10:38, Wed, Nov 04, 2015
• Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-Helton Deford-13.xml
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2015-11-04 11:30:36
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/StateiZip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or, system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agenoy:for approval with this building permit application.
Responsible Designer Name: -
Responsible Designer Signature:
Tim Scott
T.�
Company
Date Signed:
Scott Design and Title 24, Inc.
2015-11-04 11:30:36
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies
information.
Registration Number: 214-NO04761OB-000000000-0000 Registration Date/Time: 2015-11-04 11:30:36
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
CrTY OF �,q C�tJliVT,q
BUILDING & �A�eUdyurPfRtTe
Providemessponsi ilityy o�t
FOR CONSTRUCTTIIO
DATE_�_8Y
Report Generated at: 2015-11-04 10:39:46
inc.
I BUILDING ENERGY ANALYSIS REPORT
4a919:1411 IF
Monterra, Plan 3
55-101 Monroe
La Quinta, CA 92253
Project Designer:
Helton, DeFord & Associates
17411 Irvine Blvd, Suite O
Tustin, CA 92780
(909) 957-4550
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
77085 Michigan Drive
Palm Desert, CA 9221
(760) 200-4780 B' OF QUINTA
a ��NG SAFETY pEPT
PUP CON VD
CTI®N
DATE �$ (�
Job Number: REC
� V
ED
NOV 18 2015
Date: COMMUNOT1►' LA D LOPMINT
11 /4/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 6.7 by EnergySoft User Number. 6712 ID:
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF-1 R-PRF-01-E Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 13
Form MF-1 R Mandatory Measures Summary 14
HVAC System Heating and Cooling Loads Summary 18
Zone Load Summary 19
Room Load Summary 20
Room Heating Peak Loads 21
Room Cooling Peak Loads 22
EnergyPro 6.7 by EnergySoft Job Number: ID: User Number: 6712 1
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:13, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 3-Helton Deford-13.xm1
CF1 R-PRF-01
Page irof 10
GENERAL INFORMATION
01
Project Name
Monterra Plan 3
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2015
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2013-4 (744)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.6
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
N Number of Dwelling Units
1
14
Total Cond. Floor Area (ft)
3370
15
Number of Zones
1
16
Slab Area (ft2)
3370
17
4 Number of Stories
1
18
Addition Cond. Floor Area
N/A19
Natural Gas Available
Yes
r2O
Addition Slab Area (ft2)
N/A
Glazing Percentage (%)
20.7%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance "a
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below 1,
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 14:14:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation DatelTime: 14:13, Wed, Nov 04, 2015
CF1 R-PRF-01
Page 21of 10 r
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-Helton Deford-13.xml
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.66
1.23
0.43
25.9%
Space Cooling
102.26
89.99
12.27
12.0%
IAQ Ventilation
0.84
0.84
0.00
0.0%
Water Heating
7.62
7.37
0.25
3.3%
PV Credit
----
0.00
0.00
----
North Facing Compliance Total
112.38
99.43
12.95
11.5%
Space Heating
1.66
1''43
0.23
13.9%
Space Cooling
102.26
�..
4-'95.03
7.23
7.1 %
IAQ Ventilation
0.84
0.84
0.00
0.0%
Water Heating
7.62
7.37
0.25
3.3%
PV Credit
----
, 0.00
0.00
----
East Facing Compliance Total
112.38
: " ` 104.67
7.71
6.9%
Space Heating
1.66
`' 2.22
-0.56
-33.7%
Space Cooling
102.26
zs 91.36
10.90
10.7%
IAQ Ventilation
0.84
0.84
0.00
0.0%
Water Heating
7.62
7.37
0.25
3.3%
PV Credit
----
0.00
0.00
----
South Facing Compliance Total
112.38''t'
101.79
10.59
9.4%
Space Heating
1.65�3�`
1.80
-0.14
-8.4%
Space Cooling
10226
86.91
15.35
15.0%
IAQ Ventilation
<`�0.84
0.84
0.00
0.0%
Water Heating
7.62
7.37
0.25
3.3%
PV Credit
,, ,4.% ----
0.00
0.00
----
West Facing Compliance Total
112.38
96.92
15.46
13.8%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condittion'for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
Registration Number:
CA Building Energy Efficiency Stan&icls - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 14:14:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: Monterra Plan 3
Calculation Description: Title 24 Analysis
HERS FEATURE SUMMARY
Calculation Daterrime: 14:13, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 3-Helton Deford-13.xml
Page 31 of 10 r
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Ducts located entirely In conditioned space
Domestic Hot Water System Verifications:
• ..None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on -site renewable energy system.`
Reference Energy Use:
Energy Design Rating
Margin
Percent Improvement
Total Energy (kTDVff2-yr)'
152.73
145.02
7.71
5.0%
' includes calculated Appliances and Miscellaneous Energy Use (AMEU)
Y
BUILDING - FEATURES INFORMATION
01
02
r_,,03
04
05
06
07
Number of Dwelling
Number of Ventilation
Number of Water
Project Name
Conditioned Floor Area (ft2)
Units
Number of Bedrooms
Number of Zones
Cooling Systems
Heating Systems
Monterra Plan 3
3370
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Floor Area
Avg. Gelling
Zone Name
Zone Type
HVAC System Name
(tt2)
Height
Water Heating System 1
Water Heating System 2
Plan 3
Conditioned'.Q,"'
HVAC 1 & 21
3370
9
DHW Sys 1
Registration Number: * `'
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFiR-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 14:14:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 14:13, Wed, Nov 04, 2015
CF1 R-PRF-01
Page 41 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-Helton Deford-13.xml
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft)
Tllt (deg)
N Wall
Plan 3
R-21 Wall (W 19.2x6.16)
0
Front
720
91.6
90
E Wall
Plan 3
R-21 Wall (W.19.2x6.16)
90
Left
1061
192.5
90
S Wall
Plan 3
R-21 Wall (W.19.2x6.16)
180
Back
727
356.064
90
W Wall
Plan 3
R-21 Wall (W 19.2x6.16)
270
Right
1030
78
90
R-38 Roof
Plan 3
R-38 Roof (R.38.2x14.16)
3370
ATTIC `
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rlse
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Plan 3
Attic RoofPlan 3
Ventilated
436764
s 4
0.1
0.85
No
No
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 14:14:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 14:13, Wed, Nov 04, 2015
CF1 R-PRF-01
Page S of 10 t'
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-Helton Deford-13.xml
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multlpll
er
Area
(ft)
U-factor
SHGC
Exterior Shading
1.5X8 F
Window
N Wall (Front-0)
2.0
8.0
0.75
12.0
0.32
0.24
Insect Screen (default)
3.6X8 FD
Window
N Wall (Front-0)
3.5
8.0
1
28.0
0.32
0.24
Insect Screen (default)
1.5X8 F 2
Window
N Wall (Front-0)
2.0
8.0
0.75
12.0
0.32
0.24
Insect Screen (default)
3X6 SH
Window
N Wall (Front-0)
----
----
1
18.0
0.32
0.24
Insect Screen (default)
2X5 F
Window
E Wall (Left-90)
---- t .
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 2
Window
E Wall (Left-90)
-- If '
---
1
10.0
0.32
0.24
Insect Screen (default)
2X5.5 SH
Window
E Wall (Left-90)
-==
---
1
11.0
0.32
0.24
Insect Screen (default)
5X5.5 F
Window
E Wall (Left-90)
,,---
---
1
27.5
0.32
0.24
Insect Screen (default)
2X5.5 SH 2
Window
E Wall (Left-90)
----
-
1
11.0
0.32
0.24
Insect Screen (default)
2X5 F 3
Window
E Wall Left-90 ( ) ;
° ----
----
1
10.0
0.32
0.24
Insect Screen (default)
10X8 PD
Window
E Wall (Left-90)
----
----
1
80.0
0.32
0.24
Insect Screen (default)
5X5 C
Window
E Wall (Left-90)
----
----
1
25.0
0.32
0.24
Insect Screen (default)
2X4 C
Window
E Wall (Left-90)'''
----
----
1
8.0
0.32
0.24
Insect Screen (default)
6X6 SL
Window
S Wall (Back-180) w
-
----
1
36.0
0.32
0.24
Insect Screen (default)
6X8 FD
Window
S Wall (Back 180) i-gn
19.0
8.0
0.316
48.0
0.32
0.24
Insect Screen (default)
16X8 PD
Window
S Wall (Back 180) `-,:'`
----
----
1
128.0
0.32
0.24
Insect Screen (default)
5X6 SL
Window
S Wall (Back-180.);'
----
----
1
48.0
0.32
0.24
Insect Screen (default)
5X6 SL 2
Window
S Wall (Back1.80)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
6X8 FD 2
Window
S Wall (Back 180)
19.0
8.0
0.316
48.0
0.32
0.24
Insect Screen (default)
2X5 F 4
Window
W Wall:lRight-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 5
Window
W Wail (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X4 SH
Window
1 Wall (Right-270)
----
----
1
8.0
0.32
0.24
Insect Screen (default)
5X4 SL
Window
W Wall (Right-270)
----
----
1
20.0
0.32
0.24
Insect Screen (default)
2X6 SH
Window
W Wall (Right-270)
----
----
1
6.0
0.32
0.24
Insect Screen (default)
6X8 FD 3
Window`"
W Wall (Right-270)
----
----
1
24.0
0.32
0.24
Insect Screen (default)
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 14:14:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 14:13, Wed, Nov 04, 2015
CF1 R-PRF-01
Page 61 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-Helton Deford-13.xml
DOORS
01
02
03
04
Name
Side of Building
Area (ft)
U-factor
Door
N Wall
21.6
0.50
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth"'
Top Up
Dlstl-
Bot Up
Depth
Top Up
Dist R
Bot Up
1.5X8 F
10
0.1
10
10
0
? 0'
0
0
0
0
0
0
0
3.6X8 FD
10
0.1
10
10
0
0
0
0
0
0
0
0
0
1.5X8 F 2
10
0.1
10
10
0
0
0
0
0
0
0
0
0
6X8 FD
14
0.1
14
14
0 a
0
0
0
0
0
0
0
0
6X8 FD 2
14
0.1
14
14
0_
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS W."
01
02
03
eer 04
05
06
07
`
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
'
R-value
U-value
Assembly Layers
Cavity / Frame: no insul. / 2x4 Top Chrd
2c4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofPlan 3
Attic Roofs
Wood Framed Ceiling �
,. in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
-'
Cavity/Frame: R-9.1 /2x4
R-38 Roof(R.38.2xl 4.16)
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
• Exterior Finish: Wood
R-21 Wall (W.I9.2x6.16)
Exterior Walls
Wood'Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
UP
SLAB FLOORS
01
� --02
03
04
05
06
07
Name
";' Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
Plan 3
521
61
None
0.8
No
Hard Surface Slab
Plan 3
2849
280
None
0.8
No
Registration Number:
CA Building Energy Efficiency Starida'rds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 14:14:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:13, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 3-Helton Deford-13.xml
CF1 R-PRF-01
Page 71 of 10 u
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (011)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
---
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 - 1/1
DHW
Parallel Piping
DHW Heater 1
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
�,
Tank Exterior
Tank Volume
Energy Factor or
Insulation
Standby Loss
Name
Heater Element Type
Tank Type
�;F(galj
Efficiency
Input Rating
R-value
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.62
40000-Btu/hr
0
0
f_''
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Recirculation
Central DHW
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Control
Distribution
DHW Sys 1 - 1/1
---
---
---
---
---
---
SPACE CONDITIONING SYSTEMS s
01
02
03
04
05
06
SC Sys Name
System"type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC 1 & 21
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01 w'':;i;.
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
P
vs<.
Registration Number: ,' p
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 14:14:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:13, Wed, Nov 04, 2015
Input File Name: Monterra-Plan 3-Helton Deford-13.xmi
CF1 R-PRF-01
Page 811of 10 t
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
12
14
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verlfled EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350a
Required
Not Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
'fr " 04
05
06
07
Name
Type
Duct Leakage
' 'Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsInAll
Sealed and tested. '
8
Conditioned zone
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION =:
01
02
03 '1
04
05
06
07
08
i1c A
Duct Leakage
Duct Leakage
Verified Duct
Verified Duct
Burled
Deeply Buried
Low -leakage
n
Name
Verification
Target'(%)
Location
Design
Ducts
Ducts
Air Handler
Air Distribution System 1 hers dist
Requiredx
6.0
Required
Not Required
Not Required
Not Required
- -
HVAC -FAN SYSTEMS
01
02
03
04
Name
`k Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
,., " Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan R
Required
0.58
�M1
Registration Number:
CA Building Energy Efficiency Stanch ds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 14:14:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 14:13, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-Helton Deford-13.xml
CF1 R-PRF-01
Page 91of 10 a
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
63.7
0.25
Default
0
Required
r'
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 14:14:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 14:13, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-Helton Deford-13.xml
CF1 R-PRF-01
Page 1 d of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc,
11 /4/2015
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State i :
Pallm Desert, CA 92211
Phone: ;, .-.
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California: <a°
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for:the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of>Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations. C:1
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency."fgrapproval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Jim Deford ffi.
Company: `W
Date Signed:
Helton, DeFord & Associates b'
Address:
i.
License:
17411 Irvine Blvd, Suite O
City/State/Zip:
t=
Phone:
Tustin, CA 92780
(909) 957-4550
Registration Number:
>
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-11-04 14:14:01
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Monterra, Plan 3
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
111412015
Project Address
55-101 Monroe La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,370
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features
Status
Roof Wood Framed Attic
R 38 3,370
New
Wall Wood Framed
R 21 2,820
New
Door Opaque Door
- no insulation 22
New
Slab Unheated Slab -on -Grade
- no insulation 3,370 Perim = 341'
New
FENESTRATION
Orientation Area(ff)
I Total Area: 697 Glazing Percentage: 20.7 % New/Altered Average U-Factor: 0.32
U-Fac SHGC Overhang Sidefins Exterior Shades Status
Front (N) 52.0
0.320 0.24 10.0 none Bug Screen
New
Front (N) 18.0
0.320 0.24 none none Bug Screen
New
Left (E) 192.5
0.320 0.24 none none Bug Screen
New
Rear (S) 260.0
0.320 0.24 none none Bug Screen
New
Rear (S) 96.0
0.320 0.24 14.0 none Bug Screen
New
Right (tM 78.0
0.320 0.24 none none Bug Screen
New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling Min. Eff Thermostat Status
2 Central Furnace
80 % AFUE
Split Air Conditioner 14.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
HVAC 1 & 2 Ducted
Ducted Conditioned 8.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
1 Small Storage Gas
50
0.62 Parallel Piping New
EnergyPro 6.7 by EnergySoft User Number. 6712
RunCode: 2015-11-04T14:15.43 ID:
Pa a 13 of 24
2013 Low -Rise Residential Mandatory Measures Summary
NOTE.• Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may aDDly. Review the respective code section for more information.
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration that meets the requirements of §10-111(a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CF1R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U-factor shall not exceed 0.031. Minimum R-19 in a
§ I50.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ 150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R-value.
§ 150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U-
factor).
§ 150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U-factor.
In Climate Zones 14 and 16 a Class R vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§ 150.0(g)l:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class 11
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class 11 vapor retarder shall be placed over the earth floor of
§ 150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8(g).
§ 150.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U-factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§ 150.0(e)1 C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§ 150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in 150.0 h 2.
§ I50.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§ 150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.0(j)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§150.00)2C:
Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating
systems or hot water systems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ 150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ 150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class H vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSUSMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 'A inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross -sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ 150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R-value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ 150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§ 150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ 150.0(m)l l:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§ 150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a bole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy < 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ 150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of > 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§ 150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
,&013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any Pool or spa heating equipment shall be installed with at least 36 niches of pipe between filter and heater or dedicated suction
a
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ 150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 11.0.9.
§150.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-13, as applicable.
§ 150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)I C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting per electrical box.
§ 150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k) IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § I30.0(c). Night lights do not need to
be controlled by vacancy sensors.
§ 150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ 150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in § 150.0(k)2.
An Energy Management Control System (FMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if. it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§ 150.0(k)2L•
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
finictionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ 150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ 150.0(k)9B:
following requirements:
i. Shall comply with § 150.0(k)9A; or
ii. Shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I50.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ 150.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9, § 130.0, § 130.1, § 130.4, § 140.6, and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ 150.0(k)12B:
i. Comply with the applicable requirements in § 110.9, § 130.0, § 130.1, § 140.6 and § 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of tuning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10(b) through § 110.10(e).
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)l:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
'Project Name
Monterra, Plan 3
Date
11/4/2015
System Name
HVAC 1 & 2
Floor Area
3,370
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 2,198
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
39,531
4,813
913
41,768
Total Output (Btuh)
178,000
0
Output (Btuh/sqft)
52.8
572
497
Cooling System
0
0
Output per System
57,500
0
0
0
0
Total Output (Btuh)
115,000
5,887
4,813
-5,887
Total Output (Tons)
9.6
572
497
Total Output (Btuh/sgft)
34.1
Total Output (sgft/Ton)
351.7
1 46,562
36,874
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow (cfm)
4,000
Carrier 24ACA460/58CVXI 10
78,955
15,053
178,000
Airflow (cfm/sgft)
1.19
Airflow (cfm/Ton)
417.4
Outside Air (%)
0.0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
78,955
15,053
178,000
Jan 1 AM
Outside Air (cfmisqft)
0.00
Note: values above given at ARI conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS
Airstream'Temperatures at Time of Heating'Peak)
26 OF 72 OF
.:-
Outside Air
0 cfm Supply Fan
4,000 cfm
72 OF
73 OF 115 OF
U-1.1-11—.1-1-
Heating Coil
115 OF
.. ... 25
ROOMW
72 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling
Peak
112 / 78 OF 70 / 59 °F/-� 72 ! 60 OF 53 / 52 OF
Outside Air .._m
0 cfm Supply Fan Cooling Coil
4,000 cfm
70 159 OF
... -.�
53 152 OF
52.9 % ROOM
70 / 59 OF
EnergyPro 6.7 by EnergySoR User Number. 6712 RunCode: 2015-11-04T14:15.43
ID: Page 18 of 24
ZONE LOAD SUMMARY
Project Name
Monterra, Plan 3
Date
111412015
System Name
HVAC 1 & 2
Floor Area
3,370
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
I Sensible
Latent
CFM
Sensible
Plan 3
1.0
0
Aug 3 PM
2,198
39,531
4,813
913
41,768
TOTALS
0
0
0
0
Aug 3PM 1
39,5311
4,813 1
41,768
(BLOCK LOAD)
EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-11-04T14:15.43 ID: Page 19 of 24
ROOM LOAD SUMMARY
Project Name
Montema, Plan 3
Date
111412015
System Name
HVAC 1 & 2
Floor Area
3,370
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
Zone Name
Room Name
Mult.
CFM
Sensible
I Latent
CFM
Sensible
Latent
CFM
Sensible
Plan 3
Plan 3
1
2,198
39,5311
4,813
2,198
39,5311
4, 813
913
41,768
PAGE TOTAL
TOTAL
2,198
39,5311
4, 813
913
41,768
2,198
39,5311
4,8131
913
41,768
" Total includes ventilation load for zonal systems.
EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-11-04T14:15.43 ID: Page 20 of 24
ROOM HEATING PEAK LOADS
Project Name
Monterra, Plan 3
Date
111412015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Plan 3
Floor Area 3,370.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
4T OF
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
—
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof(R.38.2x14.16)
3,370.0
0.0260
46
4,031
R-21 Wall (W.19.2x6.16)
2,819.9
0.0690
46
8,950
Milgard Low-E Vinyl
696.5
0.3200
46
10,252
Wood Door
21.6
0.5000
46
497
Slab -On -Grade
perim = 341.0
0.7300
46
11,451
Items shown with an asterisk (") denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 3,370 X
Area
another room
9.00 X 0.266
Height ACH
Page Total
/ 60 ] X
AT
35,181
= 6,587
TOTAL HOURLY HEAT LOSS FOR ROOM 41,768
EnergyPro 6.7 by EnergySoft User Number., 6712 RunCode: 2015-11-04T14:15.43 ID: Page 21 of 24
dw
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Monterra, Plan 3 111412015
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Plan 3
Outdoor Dry Bulb Temperature
112 0
Floor Area
3,370.0 ft2
1
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
70 OF
Outdoor Dailv Ranae:
34 OF
Opaque Surfaces
R-38 Roof(R.38.2x 14.16)
R-21 Wall (W.19.2x6.16)
Wood Door
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
Orientation
(IM
(N)
(N)
(E)
(W)
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
3,370.0
0.0260
56.0
628.4
0.0690
23.0
21.6
0.5000
23.0
868.5
0.0690
33.0
371.0
0.0690
26.0
952.0
0.0690
33.0
Page Total
Items shown with an asterisk (") denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
1.5X8 F
3.6X8 FD
1.5X8 F
3X6 SH
2X5 F
2X5 F
2X5.5 SH
5X5.5 F
2X5.5 SH
Orientation
(N)
(N)
(N)
(N)
(E)
(E)
(E)
(E)
(E)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
15.3
12.0
15.3
0.0
15.3
28.0
15.3
0.0
15.3
12.0
15.3
0.0
15.3
18.0
15.3
0.0
15.3
10.0
29.6
0.0
15.3
10.0
29.6
0.0
15.3
11.0
29.6
0.0
15.3
27.5
29.6
0.0
15.3
11.0
29.6
Page Total
Btu/hr
4,907
248
1,978
666
2,168
10,
Btu/hr
184
3,
429
184
276
296
296
325
813
Internal Gain Btu/hr
Occupants 10.1 Occupants X 245 Btuh/occ. = Z477
Equipment 3,370 Floor Area X 0.50 W/sgft = 1 5,751
Infiltration: 1.064 X 0.94 X 139.00 X 42 = 5,81
Air Sensible CFM ELA AT
LTOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 39,5311
Latent Gain Btu/hr
Occupants 10.1 Occupants X 155 Btuh/occ. = 1,567
Infiltration: 4,771 X 0.94 X 139.00 X 0.00523 = 3,246
Air Sensible CFM ELA pW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,5671
I EnergyPro 6.7 by Enen7ySoft User Number.- 6712 RunCode: 2015-11-04T14:15.43 ID: Page 22 of 24 1
I RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Monterra, Plan 3 111412015
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Plan 3 1Outdoor
Dry Bulb Temperature
112 OF
Floor Area
3,370.0 ftz
1
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
70 OF
Outdoor Daily Rancle:
34 OF
Surfaces Orientation
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
Page Total
Items shown with an asterisk (*) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
2X5 F
10X8 PD
5X5 C
2X4 C
6X6 SL
6X8 FD
16X8 PD
5X6 SL
5X6 SL
Orientation
(E)
(E)
(E)
(E)
(S)
(S)
(S)
(S)
(S)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
0.0
15.3
10.0
29.6
0.0
15.3
80.0
29.6
0.0
15.3
25.0
29.6
0.0
15.3
8.0
29.6
0.0
15.3
36.0
15.4
48.0
15.3
0.0
15.4
0.0
15.3
128.0
15.4
0.0
15.3
48.0
15.4
0.0
15.3
48.0
Page Total
Btu/hr
Btu/hr
296
2, 364
739
236
553
735
1,966
737
737
8,3641
Internal Gain Btu/hr
Occupants 10.1 Occupants X 245 Btuh/occ. = Z477
Equipment 3,370 Floor Area X 0.50 W/sgft = 1 5,751
Infiltration: 1.064 X 0.94 X 139.00 X 42 = 5,81
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 39,5311
Latent Gain Btu/hr
Occupants 7�110.1 Occupants X 155 Btuh/occ. = 1,567
Infiltration: 4,771 x 0.94 x 139.00 x F 3,246
Air Sensible CFM ELA AW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1.567
EnergyPro 6.7 by EnergySoft User Number- 6712 RunCode: 2015-11-04T14:15.43 ID: Page 23 of 24
a
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Monterra, Plan 3
111412015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Plan 3
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,370.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area
GLF
Btu/hr
6X8 FD
(S) 48.0 X 15.3 +
0.0
X 15.4 =
735
2X5 F
(VVJ 0.0 X 15.3 +
10.0
X 29.6 =
296
2X5 F
(VV) 0.0 X 15.3 +
10.0
X 29.6 =
296
2X4 SH
(VV) 0.0 X 15.3 +
8.0
X 29.6 =
236
5X4 SL
(IM 0.0 X 15.3 +
20.0
X 29.6 =
591
2X6 SH
W 0.0 X 15.3 +
6.0
X 29.6 =
177
6X8 FD
(W) 0.0 X 15.3 +
24.0
X 29.6 =
709
X +
X =
X +
X =
Page Total
3,040
Internal Gain
Btu/hr
Occupants
10.1 Occupants X 245
Btuh/occ.
=
EZ477
Equipment
3,370 Floor Area X 0.50
W/ggft
=
5,751
Infiltration: 1.064
X 0.94 X 139.00 X 42 =
5,810
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
39,531
Latent Gain
Btu/hr
Occupants
10.1 Occupants X 155
Btuh/occ.
=
1,567
Infiltration: 4,771
X 0.94 X 139.00 X 0.00523 =
3,246
Air Sensible
CFM ELA ptn/
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,567
Ene Pro 6.7 by Ene Soft
User Number- 6712 RunCode: 2015-11-04T14:15.43 ID:
Page 24 of 24
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 14:13, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 3-Helton Deford-13.xml
CF1 R-PRF-01
Page 1 of 10
GENERAL INFORMATION
01
Project Name
Monterra Plan 3
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2015
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2013-4 (744)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.6
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
3370
15
Number of Zones
1
16
Slab, Area (ft)
3370
17
Number of Stories
1
18
Addition Cond. Floor Area
N/A
19
Natural Gas Available
Yes
[720
Addition Slab Area (ft2)
N/A
21
Glazing Percentage (%)
20.7%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
C'TY ®,ifz LA QUID
BU11DING & SAFETY Tr
APPROVED
DEPr
OIR CONS BIICTI
SATE .k4 �/S ..
Registration Number: 214-N0048321B-000000000-0000 Registration Date/Time: 2015-11-04 14:22:28 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 14:14:12
CF1 R-PRF-01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation DatelTime: 14:13, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-Helton Deford-13.xmi
Page 2 of 10
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.66
1.23
0.43
25.9%
Space Cooling
102.26
89.99
12.27
12.0%
IAQ Ventilation
0.84
0.84
0.00
0.0%
Water Heating
7.62
7.37
0.25
3.3%
PV Credit
----
0.00
0.00
----
North Facing Compliance Total
112.38
99.43
12.95
11.5%
Space Heating
1.66
1.43
0.23
13.9%
Space Cooling
102.26
95.03
7.23
7.1%
IAQ Ventilation
0.84
0.84
0.00
0.0%
Water Heating
7.62
7.37
0.25
3.3%
PV Credit
----
0.00
0.00
----
East Facing Compliance Total
112.38
104.67
7.71
6.9%
Space Heating
1.66
2.22
-0.56
-33.7%
Space Cooling
102.26
91.36
10.90
10.7%
IAQ Ventilation
0.84
0.84
0.00
0.0%
Water Heating
7.62 '
7.37
0.25
3.3%
PV Credit
----
0.00
0.00
----
South Facing Compliance Total
112.38
101.79
10.59
9.4%
Space Heating
1.66
1.80
-0.14
-8.4%
Space Cooling
102.26
86.91
15.35
15.0%
IAQ Ventilation
0.84
0.84
0.00
0.0%
Water Heating
7.62
7.37
0.25
3.3%
PV Credit
----
0.00
0.00
----
West Facing Compliance Total
112.38
96.92
15.46
13.8%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
Registration Number: 214-N0048321B-000000000-0000 Registration Date/Time: 2015-11-04 14:22:28 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-11-04 14:14:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
• Project Name: Monterra Plan 3 Calculation Date/Time: 14:13, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 3-Helton Deford-13.xml
CF1 R-PRF-01
Page 3 of 10
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAO mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Ducts located entirely in conditioned space
Domestic Hot Water System Verifications:
• -- None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on -site renewable energy system.
Reference Energy Use. ,
Energy Design Rating
Margin
Percent Improvement
Total Energy (kTDV/f2-yr)'
152.73
145.02
7.71
5.0%
• includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Monterra Plan 3
3370
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Plan 3
Conditioned
HVAC 1 & 21
3370
9
DHW Sys 1
Registration Number: 214-N0048321B-000000000-0000 Registration Date/Time: 2015-11-04 14:22:28 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08252015-744 Report Generated at: 2015-11-04 14:14:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 14:13, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 3-Helton Deford-13.xml
CF1 R-PRF-01
Page 4 of 10
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
N Wall
Plan 3
R-21 Wall (W 19.2x6.16)
0
Front
720
91.6
90
E Wall
Plan 3
R-21 Wall (W.19.2x6.16)
90
Left
1061
192.5
90
S Wall
Plan 3
R-21 Wall (W.19.2x6.16)
180
Back
727
356.064
90
W Wall
Plan 3
R-21 Wall (W 19.2x6.16)
270
Right
1030
78
90
R-38 Roof
Plan 3
R-38 Roof(R.38.2x14.16)
3370
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emlttance
Radiant Barrier
Cool Roof
Attic Plan 3
Attic RoofPlan 3
Ventilated
4.36764
0.1
0.85
1 No
No
Registration Number: 214-NO048321B-000000000-0000 Registration Date/Time: 2015-11-04 14:22:28 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 14:14:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 14:13, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-Helton Deford-13.xmi
CF1 R-PRF-01
Page 5 of 10
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orlentation-Azimuth)
Width (ft)
Height (ft)
Multipli
er
Area
(ft2)
U-factor
SHGC
Exterior Shading
1.5X8 F
Window
N Wall (Front-0)
2.0
8.0
0.75
12.0
0.32
0.24
Insect Screen (default)
3.6X8 FD
Window
N Wall (Front-0)
3.5
8.0
1
28.0
0.32
0.24
Insect Screen (default)
1.5X8 F 2
Window
N Wall (Front-0)
2.0
8.0
0.75
12.0
0.32
0.24
Insect Screen (default)
3X6 SH
Window
N Wall (Front-0)
----
----
1
18.0
0.32
0.24
Insect Screen (default)
2X5 F
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 2
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5.5 SH
Window
E Wall (Left-90)
----
----
1
11.0
0.32
0.24
Insect Screen (default)
5X5.5 F
Window
E Wall (Left-90)
----
----
1
27.5
0.32
0.24
Insect Screen (default)
2X5.5 SH 2
Window
E Wall (Left-90)
----
----
1
11.0
0.32
0.24
Insect Screen (default)
2X5 F 3
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
10X8 PD
Window
E Wall (Left-90)
----
----
1
80.0
0.32
0.24
Insect Screen (default)
5X5 C
Window
E Wall (Left-90)
--- -
1
25.0
0.32
0.24
Insect Screen (default)
2X4 C
Window
E Wall (Left-90) !
----
----
1
8.0
0.32
0.24
Insect Screen (default)
6X6 SL
Window
S Wall (Back-180)
-
----
1
36.0
0.32
0.24
Insect Screen (default)
6X8 FD
Window
S Wall (Back-180)
19.0
8.0
0.316
48.0
0.32
0.24
Insect Screen (default)
16X8 PD
Window
S Wall (Back-180)
----
----
1
128.0
0.32
0.24
Insect Screen (default)
5X6 SL
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
5X6 SL 2
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
6X8 FD 2
Window
S Wall (Back-180)
19.0
8.0
0.316
48.0
0.32
0.24
Insect Screen (default)
2X5 F 4
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 5
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X4 SH
Window
W Wall (Right-270)
----
----
1
8.0
0.32
0.24
Insect Screen (default)
5X4 SL
Window
W Wall (Right-270)
----
----
1
20.0
0.32
0.24
Insect Screen (default)
2X6 SH
Window
W Wall (Right-270)
----
----
1
6.0
0.32
0.24
Insect Screen (default)
6X8 FD 3
Window
W Wall (Right-270)
-
----
1
24.0
0.32
0.24
Insect Screen (default)
Registration Number: 214-N0048321B-000000000-0000 Registration Date/Time: 2015-11-04 14:22:28 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 14:14:12
CF1 R-PRF-01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
- Project Name: Monterra Plan 3 Calculation Date/Time: 14:13, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-Helton Deford-13.xml
Page 6 of 10
DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door
N Wall
21.6
0.50
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DIstL
Bot Up
Depth
Top Up
Dist R
Bot Up
1.5X8 F
10
0.1
10
10
0
0
0
0
0
0
0
0
0
3.6X8 FD
10
0.1
10
10
0
0
0
0
0
0
0
0
0
1.5X8F2
10
0.1
10
10
0
0
0
0
0
0
0
0
0
6X8 FD
14
0.1
14
14
0
0
0
0
0
0
0
0
0
6X8 FD 2
14
0.1
14
14
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
• Cavity / Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofPlan 3
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof(R.38.2x14.16)
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
• Exterior Finish: Wood
R-21 Wall (W.19.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
Plan 3
521
61
None
0.8
No
Hard Surface Slab
Plan 3
2849
280
None
0.8
No
Registration Number: 214-N00483218-000000000-0000 Registration Date/Time: 2015-11-04 14:22:28 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 14:14:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Datefrime: 14:13, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 3-Helton Deford-13.xml
CF1 R-PRF-01
Page 7 of 10
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
---
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 - 1/1
DHW
Parallel Piping
DHW Heater 1
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.62
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
---
---
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC 1 & 21
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Registration Number: 214-NO048321B-000000000-0000 Registration Date/Time: 2015-11-04 14:22:28 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 14:14:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 14:13, Wed, Nov 04, 2015
CF1 R-PRF-01
Page 8 of 10
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-Helton Deford-13.xml
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
12
14
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Not Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsInAll
Sealed and tested
8
Conditioned zone
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03:
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Burled
Ducts
Deeply Burled
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Required
Not Required
Not Required
Not Required
---
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Waft Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
Registration Number: 214-N0048321B-000000000-0000 Registration Date/Time: 2015-11-04 14:22:28 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08252015-744 Report Generated at: 2015-11-04 14:14:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 14:13, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 3-Helton Deford-13.xml
CF1 R-PRF-01
Page 9 of 10
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
63.7
0.25
Default
0
Required
Registration Number: 214-N0048321B-000000000-0000 Registration Date/Time: 2015-11-04 14:22:28 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08252015-744 Report Generated at: 2015-11-04 14:14:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 14:13, Wed, Nov 04, 2015
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-Helton Deford-13.xml
CF1 R-PRF-01
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
%5cazi
Company:
Signature Date:
Scott Design and Title 24, Inc.
2015-11-04 14:21:48
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Tim Scott
%ryis'cdiYi-
Company:
Date Signed:
Scott Design and Title 24, Inc.
2015-11-04 14:22:28
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 214-N0048321B-000000000-0000 Registration Date/Time: 2015-11-04 14:22:28 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-11-04 14:14:12