Loading...
Citrus - Cove TR 32751 BTCP2016-0003 (Plans 1 & 2) Title 24I BUILDING ENERGY ANALYSIS REPORT I PROJECT: The Cove at the Citrus La Quinta, CA Project Designer: I ?I DANIELIAN ASSOCIATES ARCHITECTURE -PLANNING SIXTY CORPORATE PARK IRVINE,CALI FORNIA 92606 PHONE . 949. 474. 6030 FAX • 949. 474. 1422 WWI. D A N I E L I A N. C OM Report Prepared by: F OF LA QUINTA NG & SAFETY DEPT, PROVED ONSTR CTION _Lay Job Number: RECEIVED 64093 AUG 19 2016 Date: CITY OF LA QUINTA COMMUNITY DEVELOPMENT 7/6/2016 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 Calculation Date/Time: 11:23, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1.xml CF1 R-PRF-01 Page 1 of 10 GENERAL INFORMATION 01 Project Name The Cove at the Citrus Plan 1 02 Calculation Description Title 24 Analysis 03 Project Location 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 2800 15 Number of Zones 1 16 Slab Area (ft2) 2800 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) N/A 21 Glazing Percentage (%) 17.5% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-No248718A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-04072016-744 Report Generated at: 2016-05-20 11:24:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 Calculation Date/Time: 11:23, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1.xml CF1 R-PRF-01 Page 2 of 10 - ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.23 1.24 -0.01 -0.8% Space Cooling 92.84 91.78 1.06 1.1% IAQ Ventilation 0.69 0.69 0.00 0.0% Water Heating 9.17 5.87 3.30 36.0% PV Credit ---- 0.00 0.00 ---- North Facing Compliance Total 103.93 99.58 4.35 4.2% Space Heating 1.23 1.31 -0.08 -6.5% Space Cooling 92.84 88.19 4.65 5.0% IAQ Ventilation 0.69 0.69 0.00 0.0% Water Heating 9.17 5.87 3.30 36.0% PV Credit ---- 0.00 0.00 ---- East Facing Compliance Total 103.93 96.06 7.87 7.6% Space Heating 1.23 1.49 -0.26 -21.1% Space Cooling 92.84 89.28 3.56 3.8% IAQ Ventilation 0.69 0.69 0.00 0.0% Water Heating 9.17 5.87 3.30 36.0% PV Credit ---- 0.00 0.00 ---- South Facing Compliance Total 103.93 97.33 6.60 6.4% Space Heating 1.23 1.17 0.06 4.9% Space Cooling 92.84 87.89 4.95 5.3% IAQ Ventilation 0.69 0.69 0.00 0.0% Water Heating 9.17 5.87 3.30 36.0% PV Credit ---- 0.00 0.00 ---- West Facing Compliance Total 103.93 95.62 8.31 8.0% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins Registration Number: 216-No248718A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:24:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 Calculation Description: Title 24 Analysis HERS FEATURE SUMMARY Calculation Date/Time: 11:23, Fri, May 20, 2016 Input File Name: 64093 Plan 1.xml - CF1 R-PRF-01 Page 3of10 The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • --None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 142.07 137.72 4.35 3.1% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems The Cove at the Citrus Plan 1 2800 1 1 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg, Ceiling Height Water Heating System 1 Water Heating System 2 First Floor Conditioned Split Systeml 2800 10 DHW Sys 1 Registration Number: 216-No248718A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:24:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 Calculation Date/Time: 11:23, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1.xml CF1 R-PRF-01 Page 4 of 10 _ OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) N Exterior Wall First Floor R-19 Wall 0 Back 500 111 90 E Exterior Wall First Floor R-19 Wall 90 Right 760 153 90 S Exterior Wall First Floor R-19 Wall 180 Front 325 124 90 W Exterior Wall First Floor R-19 Wall 270 Left 760 101.5 90 Interior Surface First Floor»_Garage_ R-13 Wall 175 0 Roof First Floor R-38 Roof Attic 2800 N Exterior Garage Wall _Garage_ R-0 Wall 0 Back 50 0 90 E Exterior Garage Wall _Garage_ R-0 Wall 90 Right 270 0 90 S Exterior Garage Wall _Garage_ R-0 Wall 180 Front 225 0 90 W Exterior Garage Wall _Garage_ R-0 Wall 270 Left 270 0 90 Garage Roof Garage_ R-0 Roof Attic 1 577 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic _Garage_ Attic Garage Roof Cons Ventilated 4 0.1 ` 0.85 No No Attic First Floor Attic RoofFirst Floor Ventilated 4 0.2 0.75 Yes Yes Registration Number: 216-N0248718A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-05-20 11:24:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 Calculation Date/Time: 11:23, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1.xml CF1 R-PRF-01 Page 5 of 10 - WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft2) U-factor SHGC Exterior Shading (3) 2020 FG Window N Exterior Wall (Back-0) ---- ---- 1 12.0 0.32 0.25 Insect Screen (default) 3020 SL Window N Exterior Wall (Back-0) ---- ---- 1 6.0 0.32 0.25 Insect Screen (default) 9090 OXO Window N Exterior Wall (Back-0) ---- ---- 1 81.0 0.32 0.25 Insect Screen (default) (3) 2020 FG 2 Window N Exterior Wall (Back-0) ---- ---- 1 12.0 0.32 0.25 Insect Screen (default) 5056 SL Window E Exterior Wall (Right-90) ---- ---- 1 27.5 0.32 0.25 Insect Screen (default) 3020 SL 2 Window E Exterior Wall (Right-90) ---- ---- 1 6.0 0.32 0.25 Insect Screen (default) (2) 4056 SL Window E Exterior Wall (Right-90) ---- ---- 1 44.0 0.32 0.25 Insect Screen (default) 5056 FG Window E Exterior Wall (Right-90) 5.0 5.5 1 27.5 0.32 0.25 Insect Screen (default) (2) 3080 DR Window E Exterior Wall (Right-90) 6.0 8.0 1 48.0 0.32 0.25 Insect Screen (default) 12080 OXXO Window S Exterior Wall (Front-180) 12.0 8.0 1 96.0 0.32 0.25 Insect Screen (default) FRONT DR Window S Exterior Wall (Front-180) 3.5 8.0 1 28.0 0.32 0.25 Insect Screen (default) (2) 3056 SH Window W Exterior Wall (Left-270) --- ---- 1 33.0 0.32 0.25 Insect Screen (default) 2040 SH Window W Exterior Wall (Left-270) ---- ---- 1 8.0 0.32 0.25 Insect Screen (default) 5050 SL Window W Exterior Wall (Left-270) ---- -- 1 25.0 0.32 0.25 Insect Screen (default) 2040 SH 2 Window W Exterior Wall (Left-270) -- -- 1 8.0 0.32 0.25 1 Insect Screen (default) 5056 SL 2 Window W Exterior Wall (Left-270) ---- --- 1 27.5 1 0.32 0.25 Insect Screen (default) OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 5056 FG 18 2 3 8 0 0 0 0 0 0 0 0 0 (2) 3080 DR 5 2 5 5 0 0 0 0 0 0 0 0 0 12080 OXXO 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 FRONT DR 5 2 5 5 0 1 0 0 1 0 0 0 0 0 0 Registration Number: 216-N0248718A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:24:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 Calculation Date/Time: 11:23, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1.xml CF1 R-PRF-01 Page 6of10 _ OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-value Assembly Layers • Inside Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 • Exterior Finish: Wood R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 Siding/sheathing/decking Ceilings (below Inside Finish: Gypsum Board R-0 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: no insul. /2x4 • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofFirst Floor Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-19/2x6 • Exterior Finish: Wood R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.069 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-13 / 2x4 R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 Other Side Finish: Gypsum Board SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade First Floor 2800 234.5 None 0.8 No Garage Slab _Garage_ 577 81.5 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required --- Registration Number: 216-N0248718A-000000000-0000 Registration Date/Time: 2016-07-0610:38:22 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:24:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 Calculation Date/Time: 11:23, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1.xml CF1 R-PRF-01 Page 7 of 10 _ WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/1 DHW Pipe Insulation, All Lines DHW Heater 1 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0.2 0.82 199000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1 /1 --- --- --- --- --- SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Cooling Component 1:Heating Component 1:Air Distribution System 1:HVAC Fan 1:1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 216-No248718A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:24:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 Calculation Date/Time: 11:23, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1.xml CF1 R-PRF-01 Page 8 of 10 _ HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond 12.2 14 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required Not Required --- HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 Registration Number: 216-No248718A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:24:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 Calculation Date/Time: 11:23, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1.xml CF1R-PRF-01 Page 9of10 _ IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 43 0.25 Default 0 Required Registration Number: 216-N0248718A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04072016-744 Report Generated at: 2016-05-20 11:24:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 Calculation Date/Time: 11:23, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1.xml CF1 R-PRF-01 Page 10 of 10 _ DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: n/ Roham Naderi Company: Signature Date: Gouvis Engineering Consulting Group 2016-07-05 15:50:17 Address: CEA/HERS Certification Identification (If applicable): 4400 Campus Dr n/a City/State/Zip: Phone: Newport Beach, CA 92660 949-752-1612 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Raymond Herrera Company: Date Signed: Family Development 2016-07-06 10:38:22 Address: License: 73-081 Fred Waring Drive N/A City/State/Zip: Phone: Palm Desert, CA 92260 760-578-5878 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-N0248718A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:24:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Casita Calculation Date/Time: 11:33, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Casita.xml CF1R-PRF-01 Page 1 of 10 _ GENERAL INFORMATION 01 Project Name The Cove at the Citrus Plan 1 w/ Casita 02 Calculation Description Title 24 Analysis 03 Project Location 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 07 Compliance Manager Version BEMCmpMgr 20134 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 3136 15 Number of Zones 2 16 Slab Area (ft2) 3136 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (ft) N/A 21 Glazing Percentage (%) 19.0% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-No248742A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-05-20 11:34:53 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Casita Calculation Date/Time: 11:33, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Casita.xml CF1 R-PRF-01 Page 2 of 10 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.64 1.59 0.05 3.0% Space Cooling 97.70 99.14 -1.44 -1.5% IAQ Ventilation 0.66 0.66 0.00 0.0% Water Heating 8.18 5.24 2.94 35.9% PV Credit ---- 0.00 0.00 ---- North Facing Compliance Total 108.18 106.63 1.55 1.4% Space Heating 1.64 1.84 -0.20 -12.2% Space Cooling 97.70 96.36 1.34 1.4% IAQ Ventilation 0.66 0.66 0.00 0.0% Water Heating 8.18 5.24 2.94 35.9% PV Credit ---- 0.00 0.00 ---- East Facing Compliance Total 108.18 104.10 4.08 3.8% Space Heating 1.64 2.03 -0.39 -23.8% Space Cooling 97.70 95.02 2.68 2.7% IAQ Ventilation 0.66 0.66 0.00 0.0% Water Heating 8.18 5.24 2.94 35.9% PV Credit ---- 0.00 0.00 ---- South Facing Compliance Total 108.18 102.95 5.23 4.8% Space Heating 1.64 1.57 0.07 4.3% Space Cooling 97.70 94.90 2.80 2.9% IAQ Ventilation 0.66 0.66 0.00 0.0% Water Heating 8.18 5.24 2.94 35.9% PV Credit ---- 0.00 0.00 ---- West Facing Compliance Total 108.18 102.37 5.81 5.4% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins Registration Number: 216-N0248742A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:34:53 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Casita Calculation Date/Time: 11:33, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Casita.xml HERS FEATURE SUMMARY CF1 R-PRF-01 Page 3of10 - The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Refrigerant Charge • Fan Efficacy Wafts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • --None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 144.98 143.43 1.55 1.1% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION ` 01 02 03 04 05 06 07 Number of Dwelling Number of Ventilation Number of Water Project Name Conditioned Floor Area (ft2) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems The Cove at the Citrus Plan 1 w/ 3136 1 1 2 0 1 Casita ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 First Floor Conditioned Split System1 2800 10 DHW Sys 1 Casita Conditioned Mini -Split System2 336 10 DHW Sys 1 Registration Number: 216-N0248742A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:34:53 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Casita Calculation Date/Time: 11:33, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Casita.xml CFI R-PRF-01 Page 4 of 10 - OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft2) Tilt (deg) N Exterior Wall First Floor R-19 Wall 0 Back 500 111 90 E Exterior Wall First Floor R-19 Wall 90 Right 760 153 90 S Exterior Wall First Floor R-19 Wall 180 Front 325 124 90 W Exterior Wall First Floor R-19 Wall 270 Left 760 101.5 90 Interior Surface First Floor»_Garage_ R-13 Wall 175 0 Roof First Floor R-38 Roof Attic 2800 N Exterior Wall 2 Casita R-19 Wall 0 Back 160 64 90 E Exterior Wall 2 Casita R-19 Wall 90 Right 210 33 90 S Exterior Wall 2 Casita R-19 Wall 180 Front 160 8 90 W Exterior Wall 2 Casita R-19 Wall 270 Left 210 0 90 N Exterior Garage Wall _Garage_ R-0 Wall 0 Back 50 0 90 E Exterior Garage Wall _Garage_ R-0 Wall 90 Right 270 0 90 S Exterior Garage Wall _Garage_ R-0 Wall 180 Front 225 0 90 W Exterior Garage Wall _Garage_ R-0 Wall 270 Left 270 0 90 Garage Roof _Garage_ R-0 Roof Attic 577 OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 Name Zone Type Orientatio n Area (ft2) Skylight Area (ft2) Roof Rise (x in 12) Roof Pitch Roof Tilt (deg) Roof Reflectance Roof Emittance Framing Factor Casita Roof Casita R-30 Roof Cathedral Back 336 0 0 0 0 0.1 0.85 0.1 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Garage_ Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No Attic First Floor Attic RoofFirst Floor Ventilated 4 0.2 0.75 Yes Yes Registration Number: 216-N0248742A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:34:53 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Casita Calculation Date/Time: 11:33, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Casita.xml CF1 R-PRF-01 Page 5 of 10 . WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft2) U-factor SHGC Exterior Shading (3) 2020 FG Window N Exterior Wall (Back-0) ---- ---- 1 12.0 0.32 0.25 Insect Screen (default) 3020 SL Window N Exterior Wall (Back-0) ---- ---- 1 6.0 0.32 0.25 Insect Screen (default) 9090 OXO Window N Exterior Wall (Back-0) ---- ---- 1 81.0 0.32 0.25 Insect Screen (default) (3) 2020 FG 2 Window N Exterior Wall (Back-0) ---- ---- 1 12.0 0.32 0.25 Insect Screen (default) 5056 SL Window E Exterior Wall (Right-90) ---- ---- 1 27.5 0.32 0.25 Insect Screen (default) 3020 SL 2 Window E Exterior Wall (Right-90) ---- ---- 1 6.0 0.32 0.25 Insect Screen (default) (2) 4056 SL Window E Exterior Wall (Right-90) ---- ---- 1 44.0 0.32 0.25 Insect Screen (default) 5056 FG Window E Exterior Wall (Right-90) 5.0 5.5 1 27.5 0.32 0.25 Insect Screen (default) (2) 3080 DR Window E Exterior Wall (Right-90) 6.0 8.0 1 48.0 0.32 0.25 Insect Screen (default) 12080 OXXO Window S Exterior Wall (Front-180) 12.0 8.0 1 96.0 0.32 0.25 Insect Screen (default) FRONT DR Window S Exterior Wall (Front-180) 3.5 8.0 1 28.0 0.32 0.25 Insect Screen (default) (2) 3056 SH Window W Exterior Wall (Left-270) ---- ---- 1 33.0 0.32 0.25 Insect Screen (default) 2040 SH Window W Exterior Wall (Left-270) 1 8.0 0.32 0.25 Insect Screen (default) 5050 SL Window W Exterior Wall (Left-270) ---- ---- 1 25.0 0.32 0.25 Insect Screen (default) 2040 SH 2 Window W Exterior Wall (Left-270) W --- --- 1 8.0 0.32 0.25 Insect Screen (default) 5056 SL 2 Window W Exterior Wall (Left-270) ---- ---- 1 27.5 0.32 0.25 Insect Screen (default) 8080 SDG Window N Exterior Wall 2 (Back-0) ---- ---- 1 64.0 0.32 0.25 Insect Screen (default) (2) 3056 SH 2 Window E Exterior Wall 2 (Right-90) -- ---- 1 33.0 0.32 0.25 Insect Screen (default) 2040 SH 3 Window S Exterior Wall 2 (Front-180) - -- 1 8.0 0.32 1 0.25 Insect Screen (default) OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up 5056 FG 18 2 3 8 0 0 0 0 0 0 0 0 0 (2) 3080 DR 5 2 5 5 0 0 0 0 0 0 0 0 0 12080 OXXO 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 FRONT DR 5 2 5 5 0 1 0 0 1 0 0 0 0 1 0 0 Registration Number: 216-No248742A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04072016-744 Report Generated at: 2016-05-20 11:34:53 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Casita Calculation Date/Time: 11:33, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Casita.xml CF1 R-PRF-01 Page 6 of 10 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-value Assembly Layers • Inside Finish: Gypsum Board • Cavity / Frame: no insul. / 2x4 • Exterior Finish: Wood R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 Siding/sheathing/decking Ceilings (below Inside Finish: Gypsum Board R-0 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: no insul. /2x4 • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofFirst Floor Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-19/2x6 • Exterior Finish: Wood R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.069 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-13 / 2x4 R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 Other Side Finish: Gypsum Board • Inside Finish.• Gypsum Board • Cavity / Frame: R-30 / 2x12 • Roof Deck: Wood Siding/sheathing/decking R-30 Roof Cathedral Cathedral Ceilings Wood Framed Ceiling 2x12 @ 16 in. O.C. R 30 0.036 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade First Floor 2800 234.5 None 0.8 No Casita Slab Casita 336 74 None 0.8 No Garage Slab Garage_ 577 81.5 None 0 No Registration Number: 216-N0248742A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:34:53 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Casita Calculation Date/Time: 11:33, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Casita.xml CF1 R-PRF-01 Page 7of10 - BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required --- WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/1 DHW Pipe Insulation, All Lines DHW Heater 1 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0.2 0.82 199000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 --- --- --- --- -- SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Cooling Component 1:Heating Component 1:Air Distribution System 1:HVAC Fan 1:1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name :Heat Pump System 2:Air Distribution System 2:HVAC Fan 2:2 Heat Pump Heating and Cooling System Heat Pump System 2 Heat Pump System 2 HVAC Fan 2 Air Distribution System 2 Registration Number: 216-N0248742A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:34:53 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Casita Calculation Date/Time: 11:33, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Casita.xml CFI R-PRF-01 Page 8 of 10 - HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 Heating Cooling Zonally Multispeed HERS Name Type HSPF/COP Cap 47 Cap 17 SEER EER Controlled Compressor Verification Heat Pump System 2 SplitHeatPump 8.2 12000 5100 14 11.7 No No Heat Pump System 2-hers-cool HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond 12.2 14 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Not Required Required Heat Pump System 2-hers-cool Required 350 Not Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dist Air Distribution System 2 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 2-hers-dist Registration Number: 216-N0248742A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:34:53 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Casita Calculation Date/Time: 11:33, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Casita.xml CFI R-PRF-01 Page 9 of 10 . HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required Not Required --- Air Distribution System 2-hers-dist Required 6.0 Not Required I Not Required Not Required Not Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 HVAC Fan 2-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 46.36 0.25 Default 0 Required Registration Number: 216-No248742A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CalCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:34:53 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Casita Calculation Date/Time: 11:33, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Casita.xml CF1 R-PRF-01 Page 10 of 10 - DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Roham Naderi Company: Signature Date: Gouvis Engineering Consulting Group 2016-07-05 15:52:36 Address: CEA/HERS Certification Identification (If applicable): 4400 Campus Dr n/a City/State/Zip: Phone: Newport Beach, CA 92660 949-752-1612 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Raymond Herrera Company: Date Signed: Family Development 2016-07-06 10:38:22 Address: License: 73-081 Fred Waring Drive N/A City/State/Zip: Phone: Palm Desert, CA 92260 760-578-5878 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-N0248742A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:34:53 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Pool Bath Calculation Date/Time: 11:28, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Pool Bath.xml CF1 R-PRF-01 Page 1 of 10 - GENERAL INFORMATION 01 Project Name The Cove at the Citrus Plan 1 w/ Pool Bath 02 Calculation Description Title 24 Analysis 03 Project Location 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 2844 15 Number of Zones 1 16 Slab Area (ft2) 2844 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) N/A 21 Glazing Percentage (%) 17.9% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-No248763A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:28:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Pool Bath Calculation Description: Title 24 Analysis Calculation Date/Time: 11:28, Fri, May 20, 2016 Input File Name: 64093 Plan 1 w Pool Bath.xml CF1 R-PRF-01 Page 2 of 10 - ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.23 1.24 -0.01 -0.8% Space Cooling 92.86 92.74 0.12 0.1% IAQ Ventilation 0.68 0.68 0.00 0.0% Water Heating 9.02 5.78 3.24 35.9% PV Credit ---- 0.00 0.00 ---- North Facing Compliance Total 103.79 100.44 3.35 3.2% Space Heating 1.23 1.34 -0.11 -8.9% Space Cooling 92.86 87.91 4.95 5.3% IAQ Ventilation 0.68 0.68 0.00 0.0% Water Heating 9.02 5.78 3.24 35.9% PV Credit ---- 0.00 0.00 ---- East Facing Compliance Total 103.79 95.71 8.08 7.8% Space Heating 1.23 1.47 -0.24 -19.5% Space Cooling 92.86 89.56 3.30 3.6% IAQ Ventilation 0.68 0.68 0.00 0.0% Water Heating 9.02 5.78 3.24 35.9% PV Credit ---- 0.00 0.00 ---- South Facing Compliance Total 103.79 97.49 6.30 6.1% Space Heating 1.23 1.11 0.12 9.8% Space Cooling 92.86 87.78 5.08 5.5% IAQ Ventilation 0.68 0.68 0.00 0.0% Water Heating 9.02 5.78 3.24 35.9% PV Credit ---- 0.00 0.00 ---- West Facing Compliance Total 103.79 95.35 8.44 8.1% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins Registration Number: 216-No248763A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:28:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Pool Bath Calculation Description: Title 24 Analysis HERS FEATURE SUMMARY Calculation Date/Time: 11:28, Fri, May 20, 2016 Input File Name: 64093 Plan 1 w Pool Bath.xml CF1 R-PRF-01 Page 3 of 10 The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • --None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 141.73 138.38 3.35 2.4% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Number of Dwelling Number of Ventilation Number of Water Project Name Conditioned Floor Area (ft2) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems The Cove at the Citrus Plan 1 w/ Pool Bath 2844 1 1 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 First Floor Conditioned Split System1 2844 10 DHW Sys 1 Registration Number: 216-No248763A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:28:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Pool Bath Calculation Date/Time: 11:28, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Pool Bath.xml CF1 R-PRF-01 Page 4 of 10 - OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) N Exterior Wall First Floor R-19 Wall 0 Back 500 111 90 E Exterior Wall First Floor R-19 Wall 90 Right 760 173 90 S Exterior Wall First Floor R-19 Wall 180 Front 325 124 90 W Exterior Wall First Floor R-19 Wall 270 Left 760 101.5 90 Interior Surface First Floor»_Garage_ R-13 Wall 181 0 Roof First Floor R-38 Roof Attic 2844 N Exterior Garage Wall _Garage_ R-0 Wall 0 Back 5 0 90 E Exterior Garage Wall _Garage_ R-0 Wall 90 Right 207 0 90 S Exterior Garage Wall _Garage_ R-0 Wall 180 Front 225 0 90 W Exterior Garage Wall Garage_ R-0 Wall 270 Left 270 0 90 Garage Roof _Garage_ R-0 Roof Attic 533 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic _Garage_ Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No Attic First Floor Attic RoofFirst Floor Ventilated 4 0.2 0.75 Yes Yes Registration Number: 216-N0248763A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04072016-744 Report Generated at: 2016-05-20 11:28:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Pool Bath Calculation Description: Title 24 Analysis Calculation Date/Time: 11:28, Fri, May 20, 2016 Input File Name: 64093 Plan 1 w Pool Bath.xml CF1 R-PRF-01 Page 5 of 10 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft) U-factor SHGC Exterior Shading (3) 2020 FG Window N Exterior Wall (Back-0) ---- ---- 1 12.0 0.32 0.25 Insect Screen (default) 3020. SL Window N Exterior Wall (Back-0) ---- 1 6.0 0.32 0.25 Insect Screen (default) 9090 OXO Window N Exterior Wall (Back-0) ---- ---- 1 81.0 0.32 0.25 Insect Screen (default) (3) 2020 FG 2 Window N Exterior Wall (Back-0) ---- --- 1 12.0 0.32 0.25 Insect Screen (default) 5056 SL Window E Exterior Wall (Right-90) ---- ---- 1 27.5 0.32 0.25 Insect Screen (default) 3020 SL 2 Window E Exterior Wall (Right-90) ---- ---- 1 6.0 0.32 0.25 Insect Screen (default) (2) 4056 SL Window E Exterior Wall (Right-90) ---- ---- 1 44.0 0.32 0.25 Insect Screen (default) 5056 FG Window E Exterior Wall (Right-90) 5.0 5.5 1 27.5 0.32 0.25 Insect Screen (default) (2) 3080 DR Window E Exterior Wall (Right-90) 6.0 8.0 1 48.0 0.32 0.25 Insect Screen (default) OPT 2680 DR Window E Exterior Wall (Right-90) 2.5 8.0 1 20.0 0.32 0.25 Insect Screen (default) 12080 OXXO Window S Exterior Wall (Front-180) 12.0 8.0 1 96.0 0.32 0.25 Insect Screen (default) FRONT DR Window S Exterior Wall (Front-180) 3.5 8.0 1 28.0 0.32 0.25 Insect Screen (default) (2) 3056 SH Window W Exterior Wall (Left-270) ---- ---- 1 33.0 0.32 0.25 Insect Screen (default) 2040 SH Window W Exterior Wall (Left-270) ---- - 1 8.0 0.32 0.25 Insect Screen (default) 5050 SL Window W Exterior Wall (Left-270) ---- ---- 1 25.0 0.32 0.25 Insect Screen (default) 2040 SH 2 Window W Exterior Wall (Left-270) ---- -- 1 8.0 0.32 0.25 Insect Screen (default) 5056 SL 2 Window W Exterior Wall (Left-270) ---- ---- 1 27.5 0.32 0.25 Insect Screen (default) OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 5056 FG 18 2 3 8 0 0 0 0 0 0 0 0 0 (2) 3080 DR 5 2 5 5 0 0 0 0 0 0 0 0 0 OPT 2680 DR 5 2 5 5 0 0 0 0 0 0 0 0 0 12080 OXXO 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 FRONT DR 5 2 5 5 0 0 0 0 0 0 0 0 0 Registration Number: 216-No248763A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:28:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: The Cove at the Citrus Plan 1 w/ Pool Bath Calculation Description: Title 24 Analysis Calculation Date/Time: 11:28, Fri, May 20, 2016 Input File Name: 64093 Plan 1 w Pool Bath.xml Page 6of10 - OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-value Assembly Layers • Inside Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 • Exterior Finish: Wood R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 Siding/sheathing/decking Ceilings (below Inside Finish: Gypsum Board R-0 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: no insul. /2x4 • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofFirst Floor Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-19 / 2x6 • Exterior Finish: Wood R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.069 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-13/2x4 R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 Other Side Finish: Gypsum Board SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade First Floor 2844 240.5 None 0.8 No Garage Slab _Garage_ 533 75.5 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required -- Registration Number: 216-No248763A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-05-20 11:28:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Pool Bath Calculation Date/Time: 11:28, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Pool Bath.xml CF1 R-PRF-01 Page7of10 WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/1 DHW Pipe Insulation, All Lines DHW Heater 1 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0.2 0.82 199000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 --- --- SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Cooling Component 1:Heating Component 1:Air Distribution System 1:HVAC Fan 1:1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 216-No248763A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:28:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Pool Bath Calculation Date/Time: 11:28, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Pool Bath.xml CF1 R-PRF-01 Page 8 of 10 - HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond 12.2 14 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required Not Required --- HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 Registration Number: 216-N0248763A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:28:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Pool Bath Calculation Date/Time: 11:28, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 640W Plan 1 w Pool Bath.xml CF1 R-PRF-01 Page 9 of 10 - IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 43.44 0.25 Default 0 Required Registration Number: 216-N0248763A-000000000-0000 Registration Date/Time: 2016-07-0610:38:22 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 HERS Provider: CaICERTS inc. Report Generated at: 2016-05-20 11:28:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Pool Bath Calculation Date/Time: 11:28, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Pool Bath.xml CF1 R-PRF-01 Page 10 of 10 - DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Roham Naderi Company: Signature Date: Gouvis Engineering Consulting Group 2016-07-05 15:55:45 Address: CEA/HERS Certification Identification (If applicable): 4400 Campus Dr n/a City/State/Zip: Phone: Newport Beach, CA 92660 949-752-1612 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Raymond Herrera Company: Date Signed: - Family Development 2016-07-06 10:38:22 Address: License: 73-081 Fred Waring Drive N/A City/State/Zip: Phone: Palm Desert, CA 92260 760-578-5878 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-No248763A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:28:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Outdoor Shower Calculation Date/Time: 11:37, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Outdoor Shower.xml CF1 R-PRF-01 Page 1 of 10 - GENERAL INFORMATION 01 Project Name The Cove at the Citrus Plan 1 w/ Outdoor Shower 02 Calculation Description Title 24 Analysis 03 Project Location 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 2757 15 Number of Zones 1 16 Slab Area (ft2) 2757 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (ft) N/A 21 j Glazing Percentage (%) 18.5% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-No248791A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:38:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Outdoor Shower Calculation Date/Time: 11:37, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Outdoor Shower.xml CF1 R-PRF-01 Page 2 of 10 - ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.39 1.33 0.06 4.3% Space Cooling 95.46 94.59 0.87 0.9% IAQ Ventilation 0.69 0.69 0.00 0.0% Water Heating 9.31 5.96 3.35 36.0% PV Credit ---- 0.00 0.00 ---- North Facing Compliance Total 106.85 102.57 4.28 4.0% Space Heating 1.39 1.49 -0.10 -7.2% Space Cooling 95.46 91.74 3.72 3.9% IAQ Ventilation 0.69 0.69 0.00 0.0% Water Heating 9.31 5.96 3.35 36.0% PV Credit ---- 0.00 0.00 ---- East Facing Compliance Total 106.85 99.88 6.97 6.5% Space Heating 1.39 1.71 -0.32 -23.0% Space Cooling 95.46 91.67 3.79 4.0% IAQ Ventilation 0.69 0.69 0.00 0.0% Water Heating 9.31 5.96 3.35 36.0% PV Credit ---- 0.00 0.00 ---- South Facing Compliance Total 106.85 100.03 6.82 6.4% Space Heating 1.39 1.33 0.06 4.3% Space Cooling 95.46 90.76 4.70 4.9% IAQ Ventilation 0.69 0.69 0.00 0.0% Water Heating 9.31 5.96 3.35 36.0% PV Credit ---- 0.00 0.00 ---- West Facing Compliance Total 106.85 98.74 8.11 7.6% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins Registration Number: 216-N0248791A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:38:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Outdoor Shower Calculation Description: Title 24 Analysis Calculation Date/Time: 11:37, Fri, May 20, 2016 Input File Name: 64093 Plan 1 w Outdoor Shower.xml CF1 R-PRF-01 Page 3of10 - HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • -- None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)' 145.19 140.91 4.28 2.9% ' includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION - 01 02 03 04 05 06 07 Number of Dwelling Number of Ventilation Number of Water Project Name Conditioned Floor Area (ft2) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems The Cove at the Citrus Plan 1 w/ 2757 1 1 1 0 1 Outdoor Shower ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 First Floor Conditioned Split System 2757 10 DHW Sys 1 Registratior Number: 216-N0248791A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:38:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Outdoor Shower Calculation Date/Time: 11:37, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Outdoor Shower.xml CF1 R-PRF-01 Page 4 of 10 - OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) N Exterior Wall First Floor R-19 Wall 0 Back 562 131 90 E Exterior Wall First Floor R-19 Wall 90 Right 760 153 90 S Exterior Wall First Floor R-19 Wall 180 Front 387 124 90 W Exterior Wall First Floor R-19 Wall 270 Left 760 101.5 90 Interior Surface First Floor»_Garage_ R-13 Wall 175 0 Roof First Floor R-38 Roof Attic 2757 N Exterior Garage Wall _Garage_ R-0 Wall 0 Back 50 0 90 E Exterior Garage Wall _Garage_ R-0 Wall 90 Right 270 0 90 S Exterior Garage Wall _Garage_ R-0 Wall 180 Front 225 0 90 W Exterior Garage Wall _Garage_ R-0 Wall 270 Left 270 0 90 Garage Roof _Garage_ R-0 Roof Attic 1 577 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise . Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic _Garage_ Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No Attic First Floor Attic RoofFirst Floor Ventilated 4 0.2 0.75 Yes Yes Registration Number: 216-N0248791A-000000000-0000 Registration Date/Time: 2016-07-0610:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:38:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Outdoor Shower Calculation Date/Time: 11:37, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Outdoor Shower.xml CFIR-PRF-01 Page 5 of 10 - WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft2) U-factor SHGC Exterior Shading (3) 2020 FG Window N Exterior Wall (Back-0) ---- ---- 1 12.0 0.32 0.25 Insect Screen (default) 3020 SL Window N Exterior Wall (Back-0) ---- ---- 1 6.0 0.32 0.25 Insect Screen (default) 9090 OXO Window N Exterior Wall (Back-0) ---- ---- 1 81.0 0.32 0.25 Insect Screen (default) (3) 2020 FG 2 Window N Exterior Wall (Back-0) ---- ---- 1 12.0 0.32 0.25 Insect Screen (default) 2680 SHWR DR Window N Exterior Wall (Back-0) ---- ---- 1 20.0 0.32 0.25 Insect Screen (default) 5056 SL Window E Exterior Wall (Right-90) ---- ---- 1 27.5 0.32 0.25 Insect Screen (default) 3020 SL 2 Window E Exterior Wall (Right-90) ---- ---- 1 6.0 0.32 0.25 Insect Screen (default) (2) 4056 SL Window E Exterior Wall (Right-90) ---- ---- 1 44.0 0.32 0.25 Insect Screen (default) 5056 FG Window E Exterior Wall (Right-90) 5.0 5.5 1 27.5 0.32 0.25 Insect Screen (default) (2) 3080 DR Window E Exterior Wall (Right-90) 6.0 8.0 1 48.0 0.32 0.25 Insect Screen (default) 12080 OXXO Window S Exterior Wall (Front-180) 12.0 8.0 1 96.0 0.32 0.25 Insect Screen (default) FRONT DR Window S Exterior Wall (Front-180) 3.5 8.0 1 28.0 0.32 0.25 Insect Screen (default) (2) 3056 SH Window W Exterior Wall (Left-270) ---- ---- 1 33.0 0.32 0.25 Insect Screen (default) 2040 SH Window W Exterior Wall (Left-270) --- ---- 1 8.0 0.32 0.25 Insect Screen (default) 5050 SL Window W Exterior Wall (Left-270) -- ---- 1 25.0 0.32 0.25 Insect Screen (default) 2040 SH 2 Window W Exterior Wall (Left-270) -- 1 8.0 0.32 0.25 Insect Screen (default) 5056 SL 2 Window W Exterior Wall (Left-270) ---- -- 1 27.5 0.32 1 0.25 Insect Screen (default) OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 5056 FG 18 2 3 8 0 0 0 0 0 0 0 0 0 (2) 3080 DR 5 2 5 5 0 0 0 0 0 0 0 0 0 12080 OXXO 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 FRONT DR 5 1 2 5 5 0 1 0 0 1 0 0 0 0 0 0 Registration Number: 216-N0248791A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-05-20 11:38:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Outdoor Shower Calculation Date/Time: 11:37, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Outdoor Shower.xml CF1 R-PRF-01 Page 6 of 10 - OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-value Assembly Layers • Inside Finish: Gypsum Board • Cavity / Frame: no insul. / 2x4 • Exterior Finish: Wood R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 Siding/sheathing/decking Ceilings (below Inside Finish: Gypsum Board R-0 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: no insul. /2x4 • Cavity/Frame: no insul. /2x4 Top Chid 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofFirst Floor Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-19 / 2x6 • Exterior Finish: Wood R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.069 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-13 / 2x4 R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 Other Side Finish: Gypsum Board SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade First Floor 2757 246.9 None 0.8 No Garage Slab _Garage_ 577 81.5 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required --- Registration Number: 216-No248791A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:38:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Outdoor Shower Calculation Description: Title 24 Analysis Calculation Date/Time: 11:37, Fri, May 20, 2016 Input File Name: 64093 Plan 1 w Outdoor Shower.xml CF1 R-PRF-01 Page 7 of 10 - WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/1 DHW Pipe Insulation, All Lines DHW Heater 1 1 .0% WATER HEATERS 01 02 03 04 06 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0.2 0.82 199000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 --- --- --- SPACE CONDITIONING SYSTEMS 01 02 03 04- 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Cooling Component 1:Heating Component 1:Air Distribution System 1:HVAC Fan 1:1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 216-No248791A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:38:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Outdoor Shower Calculation Date/Time: 11:37, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Outdoor Shower.xml CF1 R-PRF-01 Page 8of10 - HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Name System Type Efficiency EER SEER Zonally Controlled Multi -speed Compressor HERS Verification Cooling Component 1 SplitAirCond 12.2 14 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 "- 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required Not Required --- HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 Registration Number: 216-N0248791A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:38:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Outdoor Shower Calculation Description: Title 24 Analysis Calculation Date/Time: 11:37, Fri, May 20, 2016 Input File Name: 64093 Plan 1 w Outdoor Shower.xml CFI R-PRF-01 Page 9 of 10 - IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 42.57 0.25 Default 0 Required Registration Number: 216-N0248791A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:38:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 1 w/ Outdoor Shower Calculation Date/Time: 11:37, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 1 w Outdoor Shower.xml CF1 R-PRF-01 Page 10of10 - DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Roham Naderi Company: Signature Date: Gouvis Engineering Consulting Group 2016-07-05 16:02:15 Address: CEA/HERS Certification Identification (If applicable): 4400 Campus Dr n/a City/State/Zip: Phone: Newport Beach, CA 92660 949-752-1612 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: i•trrYy� Raymond Herrera Company: - Date Signed: Family Development 2016-07-06 10:38:22 Address: License: 73-081 Fred Waring Drive N/A City/State/Zip: Phone: Palm Desert, CA 92260 760-578-5878 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-N0248791A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:38:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 Calculation Date/Time: 10:19, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2.xml CF1 R-PRF-01 Page 1 of 10 - GENERAL INFORMATION 01 Project Name The Cove at the Citrus Plan 2 02 Calculation Description Title 24 Analysis 03 Project Location 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ftZ) 2879 15 Number of Zones 1 16 Slab Area (ftZ) 2879 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (ftZ) N/A 21 Glazing Percentage (%) 17.8% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-N0248816A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 10:20:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 Calculation Date/Time: 10:19, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2.xml CF1 R-PRF-01 Page 2of10 - ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.15 1.02 0.13 11.3% Space Cooling 92.79 90.85 1.94 2.1% IAQ Ventilation 0.68 0.68 0.00 0.0% Water Heating 8.92 5.71 3.21 36.0% PV Credit ---- 0.00 0.00 ---- North Facing Compliance Total 103.54 98.26 5.28 5.1% Space Heating 1.15 1.19 -0.04 -3.5% Space Cooling 92.79 89.77 3.02 3.3% IAQ Ventilation 0.68 0.68 0.00 0.0% Water Heating 8.92 5.71 3.21 36.0% PV Credit ---- 0.00 0.00 ---- East Facing Compliance Total 103.54 97.35 6.19 6.0% Space Heating 1.15 1.56 -0.41 -35.7% Space Cooling 92.79 89.39 3.40 3.7% IAQ Ventilation 0.68 0.68 0.00 0.0% Water Heating 8.92 5.71 3.21 36.0% PV Credit ---- 0.00 0.00 ---- South Facing Compliance Total 103.54 97.34 6.20 6.0% Space Heating 1.15 1.08 0.07 6.1 % Space Cooling 92.79 87.62 5.17 5.6% IAQ Ventilation 0.68 0.68 0.00 0.0% Water Heating 8.92 5.71 3.21 36.0% PV Credit ---- 0.00 0.00 ---- West Facing Compliance Total 103.54 95.09 8.45 8.2% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins Registration Number: 216-No248816A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 10:20:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 Calculation Date/Time: 10:19, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2.xml HERS FEATURE SUMMARY CF1 R-PRF-01 Page 3of10 - The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is j provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • --None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 141.34 136.06 5.28 3.7% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems The Cove at the Citrus Plan 2 2879 1 1 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Conditioned Area Conditioned Split System1 2879 10 DHW Sys 1 Registration Number: 216-N0248816A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 10:20:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 Calculation Date/Time: 10:19, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2.xml CF1 R-PRF-01 Page 4 of 10 - OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) N Exterior Wall Conditioned Area R-19 Wall 0 Back 500 194.94 90 E Exterior Wall Conditioned Area R-19 Wall 90 Right 780 107.5 90 S Exterior Wall Conditioned Area R-19 Wall 180 Front 280 89.1078 90 W Exterior Wall Conditioned Area R-19 Wall 270 Left 553 122 90 Interior Surface Conditioned Area»_Garage_ R-13 Wall 446 0 Roof Conditioned Area R-38 Roof Attic 2879 E Exterior Garage Wall _Garage_ R-0 Wall 90 Right 183 0 90 S Exterior Garage Wall _Garage_ R-0 Wall 180 Front 220 0 90 W Exterior Garage Wall _Garage_ R-0 Wall 270 Left 410 0 90 Garage Roof _Garage_ R-0 Roof Attic 701 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic _Garage_ Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No Attic Conditioned Area Attic RoofConditioned Area Ventilated 4 0.2 0.75 Yes Yes Registration Number: 216-N0248816A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 10:20:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 Calculation Date/Time: 10:19, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2.xml CF1 R-PRF-01 Page 5of10 - WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft2) U-factor SHGC Exterior Shading 10080 OXO Window N Exterior Wall (Back-0) 10.0 8.0 1 80.0 0.32 0.25 Insect Screen (default) (2) 3050 SH Window N Exterior Wall (Back-0) 6.0 5.0 1 30.0 0.32 0.25 Insect Screen (default) 5056 FG Window N Exterior Wall (Back-0) 5.0 56.0 0.098 27.4 0.32 0.25 Insect Screen (default) (2) 5030 SH Window N Exterior Wall (Back-0) ---- ---- 1 30.0 0.32 0.25 Insect Screen (default) 5056 FG 2 Window N Exterior Wall (Back-0) ---- ---- 1 27.5 0.32 0.25 Insect Screen (default) (2) 3056 SH Window E Exterior Wall (Right-90) ---- ---- 1 33.0 0.32 0.25 Insect Screen (default) 5050 SL Window E Exterior Wall (Right-90) ---- ---- 1 25.0 0.32 0.25 Insect Screen (default) 5056 SL Window E Exterior Wall (Right-90) ---- ---- 1 27.5 0.32 0.25 Insect Screen (default) 2640 SH Window E Exterior Wall (Right-90) ---- ---- 1 10.0 0.32 0.25 Insect Screen (default) (3) 2020 FG Window E Exterior Wall (Right-90) ---- ---- 1 12.0 0.32 0.25 Insect Screen (default) 5056 SL 2 Window S Exterior Wall (Front-180) ---- ---- 1 27.5 0.32 0.25 Insect Screen (default) 1626 SH Window S Exterior Wall (Front-180) ---- ---- 1 3.8 0.32 0.25 Insect Screen (default) MULLED DR W TRANSOM Window S Exterior Wall (Front-180) 5.5 10.5 1.001 57.8 0.32 0.25 Insect Screen (default) OPT 2680 FIR Window W Exterior Wall (Left-270) 2.5 8.0 1 20.0 0.32 0.25 Insect Screen (default) (3) 4056 SL Window W Exterior Wall (Left-270) ---- ---- 1 66.0 0.32 0.25 Insect Screen (default) (3) 4030 TRANSOM Window W Exterior Wall (Left-270) ---- ---- 1 36.0 0.32 0.25 Insect Screen (default) OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 10080 OXO 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 (2) 3050 SH 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 5056 FG 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 MULLED DR W TRANSOM 9 2 9 9 0 0 0 0 0 0 0 0 0 OPT 2680 FIR 9 2 9 9 0 0 0 0 0 0 0 0 0 Registration Number: 216-N0248816A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 10:20:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 Calculation Date/Time: 10:19, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2.xml CF1 R-PRF-01 Page 6 of 10 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-value Assembly Layers • Inside Finish: Gypsum Board • Cavity / Frame: no insul. / 2x4 • Exterior Finish: Wood R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 Siding/sheathing/decking Ceilings (below Inside Finish: Gypsum Board R-0 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: no insul. /2x4 • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofConditioned Area Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-19 / 2x6 • Exterior Finish: Wood R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.069 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-13/2x4 R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 Other Side Finish: Gypsum Board SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade Conditioned Area 2879 211.3 None 0.8 No Garage Slab _Garage_ 701 102.3 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required --- Registration Number: 216-N0248816A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 10:20:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 Calculation Date/Time: 10:19, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2.xml CFI R-PRF-01 Page 7of10 - WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/1 DHW Pipe Insulation, All Lines DHW Heater 1 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0.2 0.82 199000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 --- --- --- --- SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Cooling Component 1:Heating Component 1:Air Distribution System 1:HVAC Fan 1:1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 216-N0248816A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 10:20:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 Calculation Date/Time: 10:19, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2.xml CF1 R-PRF-01 Page 8 of 10 - HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond 12.2 14 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required Not Required --- HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 Registration Number: 216-N0248816A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CalCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 10:20:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 Calculation Date/Time: 10:19, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2.xml CF1 R-PRF-01 Page 9 of 10 - IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 43.79 0.25 Default 0 Required Registration Number: 216-No248816A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 10:20:40 .y CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 Calculation Date/Time: 10:19, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2.xml CF1 R-PRF-01 Page 10 of 10 - DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: nA�� Uvr� Roham Naderi Company: Signature Date: Gouvis Engineering Consulting Group 2016-07-05 16:04:42 Address: CEAMERS Certification Identification (If applicable): 4400 Campus Dr n/a City/State/Zip: Phone: Newport Beach, CA 92660 949-752-1612 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: G.r�rai�j Raymond Herrera Company: Date Signed: Family Development 2016-07-06 10:38:22 Address: License: 73-081 Fred Waring Drive N/A City/State/Zip: Phone: Palm Desert, CA 92260 760-578-5878 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-No248816A-000000000-0000 Registration Date/Time: 2016-07-0610:38:22 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 HERS Provider: CaICERTS inc. Report Generated at: 2016-05-20 10:20:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Guest Calculation Date/Time: 15:24, Tue, Jul 05, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Guest.xml CFI R-PRF-01 Page 1 of 10 - GENERAL INFORMATION 01 Project Name The Cove at the Citrus Plan 2 w/ Guest 02 Calculation Description Title 24 Analysis 03 Project Location 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 3119 15 Number of Zones 1 16 Slab Area (ft2) 3119 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) N/A 21 Glazing Percentage (%) 17.7% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-N0248833A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2016-07-0610:38:22 Report Version - CF1R-04072016-744 HERS Provider: CaICERTS inc. Report Generated at: 2016-07-05 15:27:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Guest Calculation Date/Time: 15:24, Tue, Jul 05, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Guest.xml CF1 R-PRF-01 Page 2 of 10 - ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.11 0.99 0.12 10.8% Space Cooling 90.21 88.13 2.08 2.3% IAQ Ventilation 0.66 0.66 0.00 0.0% Water Heating 8.23 5.27 2.96 36.0% PV Credit ---- 0.00 0.00 ---- North Facing Compliance Total 100.21 95.05 5.16 5.1% Space Heating 1.11 0.99 0.12 10.8% Space Cooling 90.21 86.85 3.36 3.7% IAQ Ventilation 0.66 0.66 0.00 0.0% Water Heating 8.23 5.27 2.96 36.0% PV Credit ---- 0.00 0.00 ---- East Facing Compliance Total 100.21 93.77 6.44 6.4% Space Heating 1.11 1.53 -0.42 -37.8% Space Cooling 90.21 88.28 1.93 2.1 % IAQ Ventilation 0.66 0.66 0.00 0.0% Water Heating 8.23 5.27 2.96 36.0% PV Credit --- 0.00 0.00 ---- South Facing Compliance Total 100.21 - 95.74 4.47 4.5% Space Heating 1.11 1.18 -0.07 -6.3% Space Cooling 90.21 83.97 6.24 6.9% IAQ Ventilation 0.66 0.66 0.00 0.0% Water Heating 8.23 5.27 2.96 36.0% PV Credit ---- 0.00 0.00 ---- West Facing Compliance Total 100.21 91.08 9.13 9.1% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins Registration Number: 216-N0248833A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-07-05 15:27:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Guest Calculation Date/Time: 15:24, Tue, Jul 05, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Guest.xml HERS FEATURE SUMMARY CF1 R-PRF-01 Page 3 of 10 - The following is a summary of the features that must be Feld -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAO mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • -- None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 137.07 132.60 4.47 3.3% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Number of Dwelling Number of Ventilation Number of Water Project Name Conditioned Floor Area (ft2) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems The Cove at the Citrus Plan 2 w/ Guest 3119 1 1 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Conditioned Area Conditioned Split Systeml 3119 10 DHW Sys 1 Registration Number: 216-No248833A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-07-05 15:27:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Guest Calculation Description: Title 24 Analysis Calculation Date/Time: 15:24, Tue, Jul 05, 2016 Input File Name: 64093 Plan 2 w Guest.xml CF1 R-PRF-01 Page 4 of 10 - OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) N Exterior Wall Conditioned Area R-19 Wall 0 Back 500 194.94 90 E Exterior Wall Conditioned Area R-19 Wall 90 Right 780 107.5 90 S Exterior Wall Conditioned Area R-19 Wall 180 Front 280 89.1078 90 W Exterior Wall Conditioned Area R-19 Wall 270 Left 751 159.5 90 Interior Surface Conditioned Area»_Garage_ R-13 Wall 246 0 Roof Conditioned Area R-38 Roof Attic 3119 E Exterior Garage Wall _Garage_ R-0 Wall 90 Right 183 0 90 S Exterior Garage Wall _Garage_ R-0 Wall 180 Front 220 0 90 W Exterior Garage Wall _Garage_ R-0 Wall 270 Left 410 0 90 Garage Roof _Garage_ R-0 Roof Attic 461 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic _Garage_ Attic Garage Roof Cons Ventilated 4- 0.1 , 0.85 No No Attic Conditioned Area Attic RoofConditioned Area Ventilated 4 0.2 0.75 Yes Yes Registration Number: 216-N0248833A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-07-05 15:27:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Guest Calculation Date/Time: 15:24, Tue, Jul 05, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Guest.xml CF1 R-PRF-01 Page 5 of 10 - WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft) U-factor SHGC Exterior Shading 10080 OXO Window N Exterior Wall (Back-0) 10.0 8.0 1 80.0 0.32 0.25 Insect Screen (default) (2) 3050 SH Window N Exterior Wall (Back-0) 6.0 5.0 1 30.0 0.32 0.25 Insect Screen (default) 5056 FG Window N Exterior Wall (Back-0) 5.0 56.0 0.098 27.4 0.32 0.25 Insect Screen (default) (2) 5030 SH Window N Exterior Wall (Back-0) --- ---- 1 30.0 0.32 0.25 Insect Screen (default) 5056 FG 2 Window N Exterior Wall (Back-0) --- - 1 27.5 0.32 0.25 Insect Screen (default) (2) 3056 SH Window E Exterior Wall (Right-90) ---- ---- 1 33.0 0.32 0.25 Insect Screen (default) 5050 SL Window E Exterior Wall (Right-90) ---- ---- 1 25.0 0.32 0.25 Insect Screen (default) 5056 SL Window E Exterior Wall (Right-90) -- - 1 27.5 0.32 0.25 Insect Screen (default) 2640 SH Window E Exterior Wall (Right-90) -- - 1 10.0 0.32 0.25 Insect Screen (default) (3) 2020 FG Window E Exterior Wall (Right-90) ---- ---- 1 12.0 0.32 0.25 Insect Screen (default) 5056 SL 2 Window S Exterior Wall (Front-180) ---- ---- 1 27.5 0.32 0.25 Insect Screen (default) 1626 SH Window S Exterior Wall (Front-180) --- ---- 1 3.8 0.32 0.25 Insect Screen (default) MULLED DR W TRANSOM Window S Exterior Wall (Front-180) 5.5 10.5 1.001 57.8 0.32 0.25 Insect Screen (default) OPT 2680 FIR Window W Exterior Wall (Left-270) 2.5 8.0 1'. 20.0 0.32 0.25 Insect Screen (default) (3) 4056 SL Window W Exterior Wall (Left-270) ---- ---- 1 - 66.0 0.32 0.25 Insect Screen (default) (3) 4030 TRANSOM Window W Exterior Wall (Left-270) ---- ---- 1 36.0 0.32 0.25 Insect Screen (default) 5056 SL 3 Window W Exterior Wall (Left-270) -- 1 27.5 0.32 0.25 Insect Screen (default) 2640 SH 2 Window W Exterior Wall (Left-270) ---- ---- 1 10.0 0.32 0.25 Insect Screen (default) Registration Number: 216-N0248833A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-07-05 15:27:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Guest Calculation Description: Title 24 Analysis Calculation Date/Time: 15:24, Tue, Jul 05, 2016 Input File Name: 64093 Plan 2 w Guest.xml CF1 R-PRF-01 Page 6 of 10 - OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up 10080 OXO 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 (2) 3050 SH 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 5056 FG 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 MULLED DR W TRANSOM 9 2 9 9 0 0 0 0 0 0 0 0 0 OPT 2680 FIR 9 2 9 9 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-value Assembly Layers • Inside Finish: Gypsum Board • Cavity / Frame: no insul. / 2x4 • Exterior Finish: Wood R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 Siding/sheathing/decking Ceilings (below Inside Finish: Gypsum Board R-0 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: no insul. /2x4 Cavity / Frame: no insuf / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofConditioned Area Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-19 / 2x6 • Exterior Finish: Wood R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.069 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R- 13 / 2x4 R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 Other Side Finish: Gypsum Board Registration Number: 216-N0248833A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 HERS Provider: CaICERTS inc. Report Generated at: 2016-07-05 15:27:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Guest Calculation Date/Time: 15:24, Tue, Jul 05, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Guest.xml CF1 R-PRF-01 Page 7 of 10 - SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade Conditioned Area 3119 241.1 None 0.8 No Garage Slab _Garage_ 461 82.5 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required --- WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/1 DHW Pipe Insulation, All Lines DHW Heater 1 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0.2 0.82 199000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 --- -- --- --- --- SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Cooling Component 1:Heating Component 1:Air Distribution System 1:HVAC Fan 1:1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Registration Number: 216-N0248833A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2016-07-06 10:38:22 Report Version - CF1R-04072016-744 HERS Provider: CaICERTS inc. Report Generated at: 2016-07-05 15:27:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Guest Calculation Date/Time: 15:24, Tue, Jul 05, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Guest.xml CF1 R-PRF-01 Page 8 of 10 - HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond 12.2 14 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required Not Required --- HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan Registration Number: 216-N0248833A-000000000-0000 Registration Date/Time: 2016-07-0610:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-07-05 15:27:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Guest Calculation Date/Time: 15:24, Tue, Jul 05, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Guest.xml CF1 R-PRF-01 Page 9 of 10 - HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 46.19 0.25 Default 0 Required Registration Number: 216-No248833A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-07-05 15:27:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Guest Calculation Date/Time: 15:24, Tue, Jul 05, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Guest.xml CF1 R-PRF-01 Page 10 of 10 - DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Roham Naderi Company: Signature Date: Gouvis Engineering Consulting Group 2016-07-05 16:07:17 Address: CEAMERS Certification Identification (If applicable): 4400 Campus Dr n/a City/State/Zip: Phone: Newport Beach, CA 92660 949-752-1612 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6,of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Raymond Herrera Company: Date Signed: - Family Development 2016-07-06 10:38:22 Address: License: 73-081 Fred Waring Drive N/A City/State/Zip: Phone: Palm Desert, CA 92260 760-578-5878 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-N0248833A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-07-05 15:27:11 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Mud Room Calculation Description: Title 24 Analysis Calculation Date/Time: 11:05, Fri, May 20, 2016 Input File Name: 64093 Plan 2 w Mud Room.xml CF1 R-PRF-01 Page 1 of 10 - GENERAL INFORMATION 01 Project Name The Cove at the Citrus Plan 2 w/ Mud Room 02 Calculation Description Title 24 Analysis 03 Project Location 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 3020 15 Number of Zones 1 16 Slab Area (ft2) 3020 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) N/A 21 Glazing Percentage (%) 17.8% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-No248841A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: The Cove at the Citrus Plan 2 w/ Mud Room Calculation Description: Title 24 Analysis Calculation Date/Time: 11:05, Fri, May 20, 2016 Input File Name: 64093 Plan 2 w Mud Room.xml Page 2 of 10 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.13 1.01 0.12 10.6% Space Cooling 91.05 89.61 1.44 1.6% IAQ Ventilation 0.67 0.67 0.00 0.0% Water Heating 8.50 5.44 3.06 36.0% PV Credit ---- 0.00 0.00 ---- North Facing Compliance Total 101.35 96.73 4.62 4.6% Space Heating 1.13 1.07 0.06 5.3% Space Cooling 91.05 87.89 3.16 3.5% IAQ Ventilation 0.67 0.67 0.00 0.0% Water Heating 8.50 5.44 3.06 36.0% PV Credit ---- 0.00 0.00 ---- East Facing Compliance Total 101.35 95.07 6.28 6.2% Space Heating 1.13 1.55 -0.42 -37.2% Space Cooling 91.05 89.29 1.76 1.9% IAQ Ventilation 0.67 0.67 0.00 0.0% Water Heating 8.50 5.44 3.06 36.0% PV Credit ---- _ 0.00 0.00 ---- South Facing Compliance Total 101.35 96.95 4.40 4.3% Space Heating 1.13 1.15 -0.02 -1.8% Space Cooling 91.05 85.63 5.42 6.0% IAQ Ventilation 0.67 0.67 0.00 0.0% Water Heating 8.50 5.44 3.06 36.0% PV Credit ---- 0.00 0.00 ---- West Facing Compliance Total 101.35 92.89 8.46 8.3% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins Registration Number: 216-N0248841A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Mud Room Calculation Description: Title 24 Analysis Calculation Date/Time: 11:05, Fri, May 20, 2016 Input File Name: 64093 Plan 2 w Mud Room.xml CF1 R-PRF-01 Page 3 of 10 - HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • --None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)• 138.58 134.18 4.40 3.2% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Number of Dwelling Number of Ventilation Number of Water Project Name Conditioned Floor Area (ft2) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems The Cove at the Citrus Plan 2 w/ 3020 1 1 1 0 1 Mud Room ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Conditioned Area Conditioned Split System 3020 10 DHW Sys 1 Registration Number: 216-N0248841A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: The Cove at the Citrus Plan 2 w/ Mud Room Calculation Description: Title 24 Analysis Calculation Date/Time: 11:05, Fri, May 20, 2016 Input File Name: 64093 Plan 2 w Mud Room.xml Page 4 of 10 - OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ftZ) Window & Door Area (ftZ) Tilt (deg) N Exterior Wall Conditioned Area R-19 Wall 0 Back 500 194.94 90 E Exterior Wall Conditioned Area R-19 Wall 90 Right 780 107.5 90 S Exterior Wall Conditioned Area R-19 Wall 180 Front 280 89.1078 90 W Exterior Wall Conditioned Area R-19 Wall 270 Left 669 147 90 Interior Surface Conditioned Area» Garage_ R-13 Wall 330 0 Roof Conditioned Area R-38 Roof Attic 3020 E Exterior Garage Wall _Garage_ R-0 Wall 90 Right 183 0 90 S Exterior Garage Wall _Garage_ R-0 Wall 180 Front 220 0 90 W Exterior Garage Wall Garage_ R-0 Wall 270 Left 410 0 90 Garage Roof _Garage_ R-0 Roof Attic 560 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic _Garage_ Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No Attic Conditioned Area Attic RoofConditioned Area Ventilated 4 0.2 0.75 Yes Yes Registration Number: 216-N0248841A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Mud Room Calculation Description: Title 24 Analysis Calculation Date/Time: 11:05, Fri, May 20, 2016 Input File Name: 64093 Plan 2 w Mud Room.xml CF1 R-PRF-01 Page 5 of 10 - WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft2) U-factor SHGC Exterior Shading 10080 OXO Window N Exterior Wall (Back-0) 10.0 8.0 1 80.0 0.32 0.25 Insect Screen (default) (2) 3050 SH Window N Exterior Wall (Back-0) 6.0 5.0 1 30.0 0.32 0.25 Insect Screen (default) 5056 FG Window N Exterior Wall (Back-0) 5.0 56.0 0.098 27.4 0.32 0.25 Insect Screen (default) (2) 5030 SH Window N Exterior Wall (Back-0) ---- ---- 1 30.0 0.32 0.25 Insect Screen (default) 5056 FG 2 Window N Exterior Wall (Back-0) -- ---- 1 27.5 0.32 0.25 Insect Screen (default) (2) 3056 SH Window E Exterior Wall (Right-90) - - - 1 33.0 0.32 0.25 Insect Screen (default) 5050 SL Window E Exterior Wall (Right-90) ---- ---- 1 25.0 0.32 0.25 Insect Screen (default) 5056 SL Window E Exterior Wall (Right-90) ---- ---- 1 27.5 0.32 0.25 Insect Screen (default) 2640 SH Window E Exterior Wall (Right-90) -- ---- 1 10.0 0.32 0.25 Insect Screen (default) (3) 2020 FG Window E Exterior Wall (Right-90) -- ---- 1 12.0 0.32 0.25 Insect Screen (default) 5056 SL 2 Window S Exterior Wall (Front-180) ---- ---- 1 27.5 0.32 0.25 Insect Screen (default) 1626 SH Window S Exterior Wall (Front-180) --- ---- 1 3.8 0.32 0.25 Insect Screen (default) MULLED DR W TRANSOM Window S Exterior Wall (Front-180) 5.5 10.5 1.001 57.8 0.32 0.25 Insect Screen (default) OPT 2680 FIR Window W Exterior Wall (Left-270) 2.5 8.0 1 20.0 0.32 0.25 Insect Screen (default) (3) 4056 SL Window W Exterior Wall (Left-270) ---- ---- 1 66.0 0.32 0.25 Insect Screen (default) (3) 4030 TRANSOM Window W Exterior Wall (Left-270) ---- ---- 1 36.0 0.32 0.25 Insect Screen (default) 5050 SH Window W Exterior Wall (Left-270) ---- ---- 1 25.0 0.32 0.25 Insect Screen (default) OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 10080 OXO 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 (2) 3050 SH 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 5056 FG 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 MULLED DR W TRANSOM 9 2 9 9 0 0 0 0 0 0 0 0 0 ` OPT 2680 FIR 9 2 9 9 0 0 0 0 0 0 0 0 0 Registration Number: 216-No248841A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Mud Room Calculation Date/Time: 11:05, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Mud Room.xml CF1 R-PRF-01 Page 6 of 10 - OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-value Assembly Layers • Inside Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 • Exterior Finish: Wood R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 Siding/sheathing/decking Ceilings (below Inside Finish: Gypsum Board R-0 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: no insul. /2x4 • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofConditioned Area Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-19 / 2x6 • Exterior Finish: Wood R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.069 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-13/2x4 R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 Other Side Finish: Gypsum Board SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade Conditioned Area 3020 232.9 None 0.8 No Garage Slab _Garage_ 560 90.7 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required --- Registration Number: 216-N0248841A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Mud Room Calculation Date/Time: 11:05, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Mud Room.xml CF1R-PRF-01 Page 7 of 10 - WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/1 DHW Pipe Insulation, All Lines DHW Heater 1 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0.2 0.82 199000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 --- --- SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Cooling Component 1:Heating Component 1:Air Distribution. System 1:HVAC Fan 1:1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 216-N0248841A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Mud Room Calculation Description: Title 24 Analysis Calculation Date/Time: 11:05, Fri, May 20, 2016 Input File Name: 64093 Plan 2 w Mud Room.xml CF1 R-PRF-01 Page 8 of 10 - HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Name System Type Efficiency EER SEER Zonally Controlled Multi -speed Compressor HERS Verification Cooling Component 1 SplitAirCond 12.2 14 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 .03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required Not Required --- HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 Registration Number: 216-N0248841A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Mud Room Calculation Date/Time: 11:05, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Mud Room.xml CFI R-PRF-01 Page 9of10 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 45.2 0.25 Default 0 Required Registration Number: 216-N0248841A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w/ Mud Room Calculation Date/Time: 11:05, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Mud Room.xml CF1 R-PRF-01 Page 10 of 10 - DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Roham Naderi Company: Signature Date: Gouvis Engineering Consulting Group 2016-07-05 16:08:56 Address: CEA/HERS Certification Identification (If applicable): 4400 Campus Dr n/a City/State/Zip: Phone: Newport Beach, CA 92660 949-752-1612 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: GiK�i�tPJt�i Raymond Herrera Company: Date Signed: Family Development 2016-07-06 10:38:22 Address: License: 73-081 Fred Waring Drive N/A City/State/Zip: Phone: Palm Desert, CA 92260 760-578-5878 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-No248841A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w Outdoor Shower Calculation Date/Time: 11:16, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Outdoor Shower.xml CF1 R-PRF-01 Page 1 of 10 - GENERAL INFORMATION 01 Project Name The Cove at the Citrus Plan 2 w Outdoor Shower 02 Calculation Description Title 24 Analysis 03 Project Location 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 _ Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 2842 15 Number of Zones 1 16 Slab Area (ft2) 2842 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) N/A 21 Glazing Percentage (%) 19.6% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 216-No248854A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-05-20 11:17:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: The Cove at the Citrus Plan 2 w Outdoor Shower Calculation Description: Title 24 Analysis Calculation Date/Time: 11:16, Fri, May 20, 2016 Input File Name: 64093 Plan 2 w Outdoor Shower.xml Page 2 of 10 - ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.28 1.13 0.15 11.7% Space Cooling 96.83 94.14 2.69 2.8% IAQ Ventilation 0.68 0.68 0.00 0.0% Water Heating 9.03 5.78 3.25 36.0% PV Credit ---- 0.00 0.00 ---- North Facing Compliance Total 107.82 101.73 6.09 5.6% Space Heating 1.28 1.37 -0.09 -7.0% Space Cooling 96.83 94.07 2.76 2.9% IAQ Ventilation 0.68 0.68 0.00 0.0% Water Heating 9.03 5.78 3.25 36.0% PV Credit ---- 0.00 0.00 ---- East Facing Compliance Total 107.82 101.90 5.92 5.5% Space Heating 1.28 1.70 -0.42 -32.8% Space Cooling 96.83 93.03 3.80 3.9% IAQ Ventilation 0.68 0.68 0.00 0.0% Water Heating 9.03 5.78 3.25 36.0% PV Credit ---- - 0.00 0.00 ---- South Facing Compliance Total 107.82 101.19 6.63 6.1% Space Heating 1.28 1.20 0.08 6.3% Space Cooling 96.83 91.65 5.18 5.3% IAQ Ventilation 0.68 0.68 0.00 0.0% Water Heating 9.03 5.78 3.25 36.0% PV Credit ---- 0.00 0.00 ---- West Facing Compliance Total 107.82 99.31 8.51 7.9% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins Registration Number: 216-N0248854A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:17:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: The Cove at the Citrus Plan 2 w Outdoor Shower Calculation Description: Title 24 Analysis HERS FEATURE SUMMARY Calculation Date/Time: 11:16, Fri, May 20, 2016 Input File Name: 64093 Plan 2 w Outdoor Shower.xml Page 3of10 - The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • -- None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 145.78 139.86 5.92 4.1% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Number of Dwelling Number of Ventilation Number of Water Project Name Conditioned Floor Area (ft2) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems The Cove at the Citrus Plan 2 w 2842 1 1 1 0 1 Outdoor Shower ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg, Ceiling Height Water Heating System 1 Water Heating System 2 Conditioned Area Conditioned Split System 2842 10 DHW Sys 1 Registration Number: 216-N0248854A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:17:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w Outdoor Shower Calculation Date/Time: 11:16, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Outdoor Shower.xml CF1 R-PRF-01 Page 4 of 10 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) N Exterior Wall Conditioned Area R-19 Wall 0 Back 556 214.94 90 E Exterior Wall Conditioned Area R-19 Wall 90 Right 780 119.5 90 S Exterior Wall Conditioned Area R-19 Wall 180 Front 336 101.608 90 W Exterior Wall Conditioned Area R-19 Wall 270 Left 553 122 90 Interior Surface Conditioned Area»_Garage_ R-13 Wall 446 0 Roof Conditioned Area R-38 Roof Attic 2842 E Exterior Garage Wall _Garage_ R-0 Wall 90 Right 183 0 90 S Exterior Garage Wall _Garage_ R-0 Wall 180 Front 220 0 90 W Exterior Garage Wall _Garage_ R-0 Wall 270 Left 410 0 90 Garage Roof Garage_ R-0 Roof Attic 701 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emtttance Radiant Barrier Cool Roof Attic _Garage_ Attic Garage Roof Cons Ventilated -- 4 0.1 0.85 No No Attic Conditioned Area Attic RoofConditioned Area Ventilated `" 4 0.2 0.75 Yes Yes Registration Number: 216-No248854A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-05-20 11:17:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w Outdoor Shower Calculation Date/Time: 11:16, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Outdoor Shower.xml CF1R-PRF-01 Page 5 of 10 - WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft2) U-factor SHGC Exterior Shading 10080 OXO Window N Exterior Wall (Back-0) 10.0 8.0 1 80.0 0.32 0.25 Insect Screen (default) (2) 3050 SH Window N Exterior Wall (Back-0) 6.0 5.0 1 30.0 0.32 0.25 Insect Screen (default) 5056 FG Window N Exterior Wall (Back-0) 5.0 56.0 0.098 27.4 0.32 0.25 Insect Screen (default) (2) 5030 SH Window N Exterior Wall (Back-0) ---- ---- 1 30.0 0.32 0.25 Insect Screen (default) 5056 FG 2 Window N Exterior Wall (Back-0) ---- ---- 1 27.5 0.32 0.25 Insect Screen (default) 2680 SHWR DR Window N Exterior Wall (Back-0) --- - - 1 20.0 0.32 0.25 Insect Screen (default) (2) 3056 SH Window E Exterior Wall (Right-90) ---- ---- 1 33.0 0.32 0.25 Insect Screen (default) 5050 SL Window E Exterior Wall (Right-90) ---- ---- 1 25.0 0.32 0.25 Insect Screen (default) 5056 SL Window E Exterior Wall (Right-90) 1 27.5 0.32 0.25 Insect Screen (default) 2640 SH Window E Exterior Wall (Right-90) ---- ---- 1 10.0 0.32 0.25 Insect Screen (default) (3) 2020 FG Window E Exterior Wall (Right-90) ---- ---- 1 12.0 0.32 0.25 Insect Screen (default) (2) 2050 FG Window E Exterior Wall (Right-90) -- --- 1 12.0 0.32 0.25 Insect Screen (default) 5056 SL 2 Window S Exterior Wall (Front-180) -- --- 1 27.5 0.32 0.25 Insect Screen (default) 1626 SH Window S Exterior Wall (Front-180) ---- ---- 1 3.8 0.32 0.25 Insect Screen (default) MULLED DR W TRANSOM Window S Exterior Wall (Front-180) 5.5 10.5 1.001 57.8 0.32 0.25 Insect Screen (default) 2650 FG Window S Exterior Wall (Front-180) ---- ---- 1 12.5 0.32 0.25 Insect Screen (default) OPT 2680 FIR Window W Exterior Wall (Left-270) 2.5 8.0 1 20.0 0.32 0.25 Insect Screen (default) (3) 4056 SL Window W Exterior Wall (Left-270) - ---- 1 66.0 0.32 0.25 1 Insect Screen (default) (3) 4030 TRANSOM Window W Exterior Wall (Left-270) -- --- 1 36.0 0.32 0.25 1 Insect Screen (default) Registration Number: 216-N0248854A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:17:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w Outdoor Shower Calculation Date/Time: 11:16, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Outdoor Shower.xml CFI R-PRF-01 Page 6 of 10 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 1 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up 10080 OXO 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 (2) 3050 SH 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 5056 FG 16 5.5 5.5 3 0 0 0 0 0 0 0 0 0 MULLED DR W TRANSOM 9 2 9 9 0 0 0 0 0 0 0 0 0 OPT 2680 FIR 9 2 9 9 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-value Assembly Layers • Inside Finish: Gypsum Board • Cavity / Frame: no insul. / 2x4 • Exterior Finish: Wood R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 Siding/sheathing/decking Ceilings (below Inside Finish: Gypsum Board R-0 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: no insul. /2x4 • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofConditioned Area Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-19 / 2x6 • Exterior Finish: Wood R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.069 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-13/2x4 R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 Other Side Finish: Gypsum Board Registration Number: 216-N0248854A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:17:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w Outdoor Shower Calculation Date/Time: 11:16, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Outdoor Shower.xml CFI R-PRF-01 Page 7of10 - SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade Conditioned Area 2842 222.5 None 0.8 No Garage Slab _Garage_ 701 102.3 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required --- WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/1 DHW Pipe Insulation, All Lines DHW Heater 1 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume, (gal) Energy, Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0.2 0.82 199000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 — --- --- --- --- --- SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Cooling Component 1:Heating Component 1:Air Distribution System 1:HVAC Fan 1:1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Registration Number: 216-NQ248854A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:17:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w Outdoor Shower Calculation Date/Time: 11:16, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Outdoor Shower.xml CF1 R-PRF-01 Page 8 of 10 - HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond 12.2 14 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08' Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required Not Required --- HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan Registration Number: 216-No248854A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:17:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w Outdoor Shower Calculation Date/Time: 11:16, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Outdoor Shower.xml CF1 R-PRF-01 Page 9 of 10 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 43.42 0.25 Default 0 Required Registration Number: 216-No248854A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:17:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: The Cove at the Citrus Plan 2 w Outdoor Shower Calculation Date/Time: 11:16, Fri, May 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 64093 Plan 2 w Outdoor Shower.xml CF1 R-PRF-01 Page 10 of 10 - DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: en�� O?A" c�vac" Roham Naderi Company: Signature Date: Gouvis Engineering Consulting Group 2016-07-05 16:11:30 Address: CEA/HERS Certification Identification (If applicable): 4400 Campus Dr n/a City/State/Zip: Phone: Newport Beach, CA 92660 949-752-1612 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: c�a�rrai�� Raymond Herrera Company: Date Signed: - Family Development 2016-07-06 10:38:22 Address: License: 73-081 Fred Waring Drive N/A City/State/Zip: Phone: Palm Desert, CA 92260 760-578-5878 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-No248854A-000000000-0000 Registration Date/Time: 2016-07-06 10:38:22 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-05-20 11:17:09 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance avvroach used. Exceptions may avDly. Review the respective code section for more information. Building Envelope Measures: §I 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirements of §10-111(a). §110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CFIR. §110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U-factor shall not exceed 0.031. Minimum R-19 in a § I50.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-value. § 150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U- factor). § 150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U-factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §150.0(g)l: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of § 150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8( . 150.0 § (q)' Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U- factor of 0.58; or the weighted average U-factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e) IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §I50.0(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §I50.0(e)IC: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § 150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §I10.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §I10.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §150.0(h)l: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in § 150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.00)IA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.0(j)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § I50.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. C 2013 Low -Rise Residential Mandatory Measures Summary § 150,00)2C: Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For §150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I § 150.00)3B: or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)l : space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. §150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § 150,0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R-value ratings; duct insulation thickness; and duct labeling. § 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The § 150.0(m)13: space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy < 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, § 150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of > 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(o): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §150,0(o)lA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013 Low -Rise Residential Mandatory Measures Summary § 110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. §I I0.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro- grammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § I50.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-13, as applicable. §I50.0(k)IB: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § I50.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k)] C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. § 150.0(k)] D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)IF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § I50.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. §I50.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §I50.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. § I50.0(k)21: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § I50.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § 150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. § I50.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. § 150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § 150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 1013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § 150.0(k)9B: following requirements: i. Shall comply with §150.0(k)9A; or ii. Shall comply with the applicable requirements in § 110.9, §130.0, § 130.2, §130.4, § 140.7 and § 141.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I50.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. § 150.0(k)l 0: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to §130.0(c). § 150.0(k)l 1: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in §110.9, §130.0, §130.1, §130.4, §140.6, and §141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of §150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §150.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)l: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10(b) through § 110.10(e). § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. § 110.10(e)l : The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric".