Loading...
Griffin Ranch TR 32879 BTCP2017-0012 (Plans 1-8) 2016 Code Update Revision 2 - Title 24r I cr %k"u r F-U TITLE 24, INC. 7544 SADDLEHILL TRAIL, ORANGE, CA 92869 • (714) 771-1507 • FAX (714) 771-2939 • T-24@socal.rr.com Owner: Lennar Homes/Corona 980 Montecito Drive, Suite #302 Corona, CA 92879 Designer: The McKinley Associates, Inc. 1818 First Avenue San Diego, CA 92101 March 24, 2017 Revised: 09/07/17 (Glass Areas — Delta 1) Revised: 11/20/17 (Frame Walk — Delta 2) RECEIVED JAN 17 2018 UINTA COMMUNITY CITY OF LA Q DEVELOPMENT Project: "Griffin Ranch 2017" Plans 1(2967), 1X(3271), 2(3314), 3(3475), 4(38 8 5(4154) & 6(4529) 7(4700) & 8(4820) 1 cf Y,,D1 Z' CC) y La Quinta, California CITY OF LA QUINTA Job No. 02-17 BUILDING & SAFETY DEPT. l TION FoP oROVNSTRU�ED AN These Calculations contain all the building features and performance specifications required for compliance by the California Code of Regulations Title 24, Part 1, Administrative Requirements; Part 6, Building Energy Efficiency Standards; and portions of Title 20, Appliance Efficiency Standards. When these features are incorporated into the architectural plans the design will be in compliance with the 2016 Energy Efficiency Standards as they apply in the specified Climate Zone for residential buildings using a California Energy Commission approved compliance method. rr r r AB.EC California Association of Building Energy Consultants [01=:411121=DR=01=.4eVAFA 0 rrLlWd%'l0 Rick Maurer R13-90-10024 Prepared By: Rick Maurer Certified Energy Analyst Certificate No. R13-90-10024 California State License No. 502290 C20 ** SUMMARY SHEET ** Prooect• Lennar Homes -- La Quinta, CA Zone: 15 "Griffin Ranch 2017" Plan U2967) Wall Insulation: R-15 in 2x4 Exterior Walls (Quality Insulation Installation) R-21 in 2x6 or Greater Exterior Walls (Quality Insulation Installation) Ceiling Insulation: R-30 with Spray Foam Below Roof Deck for Conditioned Unvented Attic (Quality Insulation Installation) Radiant Foil Barrier: Not Required Cool Roof (CRRC): Required with .16 Min. Aged Reflectance and .89 Min. Aged Emissivity Raised Floor Insulation: N/A Solar PV: Not Required Whole House Fan: Not Required Minimum Furnace AFUE: 92% AFUE Low Leakage Furnace to be Rater Verified Minimum Heating Capacity: 32,407 BTUH Minimum A/C STEER: 14.0 SEER/12.0 EER Rater Verified Adequate Cooling Coil Airflow to be Rater Verified Fan;Watt Draw to be Rater Verified Refrigerant Charge Test to be Rater Verified ? A/C Tonnage: Min.Sens.= 38,170 @ 115* (A/C Size By Mechanical Contractor) Duct Insulation: R-6.0 For Ducts & Plenurris`ALL in Conditioned Spaces 1, . _ _ , . , _ _Duct,Leakage Test Required Glazing: All,fenestration.will-have dual pane Low-E glass and the following maximum NFRC values: -- '-- - _' --= U-factor SHGC U-factor SHGC Operable .30 .23 Stacking Glass Door .32 .20 Fixed .26 .25 Folding Window .32 .19 Hinged Glass Door .30 .23 Sliding Glass Door .28 .22 Note(s): 1) All hot water lines will be insulated with a minimum of 1 inch insulation. This is in addition to the insulation required by the mandatory requirements per Sec. 150.00)2. 2) The water heater for this house will have a hot water demand type recirculating system with manual control. 3) This house will have a tankless water heater with a uniform energy factor (UEF) of .92 or greater and sized per the owner's specifications. 4) Quality Insulation Installation (QII) is required for this project. Coordinate requirements with the HERS rater prior to beginning construction. Multiple inspections are required during the construction process. You must get approval from the HERS rater prior to drywall. ** SUMMARY SHEET ** Project: Lennar Homes -- La Quinta, CA Zone: 15 "Griffin Ranch 2017" Plan 1X(3271) Wall Insulation: R-15 in 2x4 Exterior Walls (Quality Insulation Installation) R-21 in 2x6 or Greater Exterior Walls (Quality Insulation Installation) Ceiling Insulation: R-30 with Spray Foam Below Roof Deck for Conditioned Unvented Attic (Quality Insulation Installation) Radiant Foil Barrier: Not Required Cool Roof (CRRC): Required with .16 Min. Aged Reflectance and .89 Min. Aged Emissivity Raised Floor Insulation: N/A Solar PV: Not Required Whole House Fan: Not Required Minimum Furnace AFUE: House = 92% AFUE Low Leakage Furnace to be Rater Verified Casita = 8.2 HSPF (Heat/Pump) Minimum Heating Capacity: House = 34,810 BTUH Casita = 6,737 BTUH Minimum A/C SEER: House = 14.0 SEER/12.0 EER Rater Verified Casita = 14.0 SEER/11.0 EER Adequate Cooling Coil Airflow to be Rater Verified Fan Watt Draw to be Rater Verified Refrigerant Charge Test to be Rater Verified A/C Tonnage: House = 40,457 @ 115* Min.Sens. (A/C Size By Mechanical Contractor) Casita = 5,409 @ 1150 Min.Sens. (A/C Size By Mechanical Contractor) Duct Insulation: R-6.0 For Ducts & Plenums ALL in Conditioned Spaces Duct Leakage Test Required Glazing: All fenestration will have dual pane Low-E glass and the following maximum NFRC values: U-factor SHGC U-factor SHGC Operable .30 .23 Stacking Glass Door .32 .20 Fixed .26 .25 Folding Window .32 .19 Hinged Glass Door .30 .23 Sliding Glass Door .28 .22 Note(s): 1) All hot water lines will be insulated with a minimum of 1 inch insulation. This is in addition to the insulation required by the mandatory requirements per Sec. 150.00)2. 2) The water heater for this house will have a hot water demand type recirculating system with manual control. 3) This house will have a tankless water heater with a uniform energy factor (UEF) of .92 or greater and sized per the owner's specifications. 4) Quality Insulation Installation (Q11) is required for this project. Coordinate requirements with the HERS rater prior to beginning construction. Multiple inspections are required during the construction process. You must get approval from the HERS rater prior to drywall. ** SUMMARY SHEET ** Project: Lennar Homes -- La Quinta, CA. Zone: 15 "Griffin Ranch 2017" Plan 2(3314) Wall Insulation: R-15 in 2x4 Exterior Walls (Quality Insulation Installation) R-21 in 2x6 or Greater Exterior Walls (Quality Insulation Installation) Ceiling Insulation: R-30 with Spray Foam Below Roof Deck for Conditioned Unvented Attic (Quality Insulation Installation) Radiant Foil Barrier: Not Required Cool Roof (CRRC): Required with .16 Min. Aged Reflectance and .89 Min. Aged Emissivity Raised Floor Insulation: N/A Solar PV: Not Required Whole House Fan: Not Required Minimum Furnace AFUE: 92% AFUE Low Leakage Furnace to be Rater Verified Minimum Heating Capacity: 35,890 BTUH Minimum A/C SEER: 14.0 SEER/12.0 EER Rater Verified Adequate Cooling Coil Airflow to be Rater Verified Fan Watt Draw to be Rater Verified Refrigerant Charge Test to be Rater Verified A/C Tonnage: Min.Sens.= 43,593 @ 1150 (A/C Size By Mechanical Contractor) Duct Insulation: R-6.0 For Ducts & Plenums ALL in Conditioned Spaces Duct Leakage Test Required Glazing: All fenestration will have dual pane Low-E glass and the following maximum NFRC values: U-factor SHGC U-factor SHGC Operable .30 .23 Stacking Glass Door .32 .20 Fixed .26 .25 Folding Window .32 .19 Hinged Glass Door .30 .23 Sliding Glass Door .28 .22 Note(s): 1) All hot water lines will be insulated with a minimum of 1 inch insulation. This is in addition to the insulation required by the mandatory requirements per Sec. 150.00)2. 2) The water heater for this house will have a hot water demand type recirculating system with manual control. 3) This house will have a tankless water heater with a uniform energy factor (UEF) of .92 or greater and sized per the owner's specifications. 4) Quality Insulation Installation (QII) is required for this project. Coordinate requirements with the HERS rater prior to beginning construction. Multiple inspections are required during: the construction process. You must get approval from the HERS rater prior to drywall. ** SUMMARY SHEET ** Project: Lennar Homes -- La Quinta. CA Zone:_ _ 15 "Griffin Ranch 2017" Plan 3(3475). Wall Insulation: R-15 in 2x4 Exterior Walls (Quality Insulation Installation) R-21 in 2x6 or Greater Exterior Walls (Quality Insulation Installation) Ceiling Insulation: R-30 with Spray Foam Below Roof Deck for Conditioned Unvented Attic (Quality Insulation Installation) Radiant Foil Barrier: Not Required Cool Roof (CRRC): Required with .16 Min. Aged Reflectance and .89 Min. Aged Emissivity Raised Floor Insulation: N/A Solar PV: Not Required Whole House Fan: Not Required Minimum Furnace AFUE: 92% AFUE Low Leakage Furnace to be Rater Verified Minimum Heating Capacity: 41,847 BTUH Minimum A/C SEER: 14.0 SEER/12.0 EER Rater Verified Adequate Cooling Coil Airflow to be Rater Verified Fan Watt Draw to be Rater Verified Refrigerant Charge Test to be Rater Verified A/C Tonnage: Min.Sens.= 48,917 @ 1150 (A/C Size By Mechanical Contractor) Duct Insulation: R-6.0 For Ducts & Plenums ALL in Conditioned Spaces Duct Leakage Test Required Glazing: All fenestration will have dual pane Low-E glass and the following maximum NFRC values: U-factor SHGC U-factor SHGC Operable .30 .23 Stacking Glass Door .32 .20 Fixed .26 .25 Folding Window .32 .19 Hinged Glass Door .30 .23 Sliding Glass Door .28 .22 Note(s): 1) All hot water lines will be insulated with a minimum of 1 inch insulation. This is in addition to the insulation required by the mandatory requirements per Sec. 150.00)2. 2) The water heater for this house will have a hot water demand type recirculating system with manual control. 3) This house will have a tankless water heater with a uniform energy factor (UEF) of .92 or greater and sized per the owner's specifications. 4) Quality Insulation Installation (QII) is required for this project. Coordinate requirements with the HERS rater prior to beginning construction. Multiple inspections are required during the construction process. You must get approval from the HERS rater prior to drywall. ** SUMMARY SHEET ** Proiect: Lennar.Homes -- La Quinta, CA Zone: 15 "Griffin Ranch 2017" Plan 4(3818) Wall Insulation: R-15 in 2x4 Exterior Walls (Quality Insulation Installation) R-21 in 2x6 or Greater Exterior Walls (Quality Insulation Installation) Ceiling Insulation: R-30 with Spray Foam Below Roof Deck for Conditioned Unvented Attic (Quality Insulation Installation) Radiant Foil Barrier: Not Required Cool Roof (CRRC): Required with .16 Min. Aged Reflectance and .89 Min. Aged Emissivity Raised Floor Insulation: N/A Solar PV: Not Required Whole House Fan: Not Required Minimum Furnace AFUE: 92% AFUE Low Leakage Furnace to be Rater Verified Minimum Heating Capacity: 41,937 BTUH Minimum A/C SEER: 14.0 SEER/12.0 EER Rater Verified Adequate Cooling Coil Airflow to be Rater Verified Fan Watt Draw to be Rater Verified Refrigerant Charge Test to be Rater Verified A/C Tonnage: Min.Sens.= 49,669 @ 1150 (A/C Size By Mechanical Contractor) Duct Insulation: R-6.0 For Ducts & Plenums ALL in Conditioned Spaces Duct Leakage Test Required Glazing: All fenestration will have dual pane Low-E glass and the following maximum NFRC values: U-factor SHGC U-factor SHGC Operable .30 .23 Stacking Glass Door .32 .20 Fixed .26 .25 Folding Window .32 .19 Hinged Glass Door .30 .23 Sliding Glass Door .28 .22 Note(s): 1) All hot water lines will be insulated with a minimum of 1 inch insulation. This is in addition to the insulation required by the mandatory requirements per Sec. 150.00)2. 2) The water heater for this house will have a hot water demand type recirculating system with manual control. 3) This house will have a tankless water heater with a uniform energy factor (UEF) of .92 or greater and sized per the owner's specifications. 4) Quality Insulation Installation (QII) is required for this project. Coordinate requirements with the HERS rater prior to beginning construction. Multiple inspections are required during the construction process. You must get approval from the HERS rater prior to drywall. ** SUMMARY SHEET ** Proiect: Lennar Homes -- La Quinta, CA Zone: 15 "Griffin Ranch 2017" Plan 5(4154) Wall Insulation: R-15 in 2x4 Exterior Walls (Quality Insulation Installation) R-21 in 2x6 or Greater Exterior Walls (Quality Insulation Installation) Ceiling Insulation: R-30 with Spray Foam Below Roof Deck for Conditioned Unvented Attic (Quality Insulation Installation) Radiant Foil Barrier: Not Required Cool Roof (CRRC): Required with .16 Min. Aged Reflectance and .89 Min. Aged Emissivity Raised Floor Insulation: N/A Solar PV: Not Required Whole House Fan: Not Required Minimum Furnace AFUE: 92% AFUE Low Leakage Furnace to be Rater Verified Minimum Heating Capacity: 41,515 BTUH Minimum A/C SEER: 14.0 SEER/12.0 EER Rater Verified Adequate Cooling Coil Airflow to be Rater Verified Fan Watt Draw to be Rater Verified Refrigerant Charge Test to be Rater Verified A/C Tonnage: Min.Sens.= 51,804 @ 115° (A/C Size By Mechanical Contractor) Duct Insulation: R-6.0 For Ducts & Plenums ALL in Conditioned Spaces Duct Leakage Test Required Glazing: All fenestration will have dual pane Low-E glass and the following maximum NFRC values: U-factor SHGC U-factor SHGC Operable .30 .23 Stacking Glass Door .32 .20 Fixed .26 .25 Folding Window .32 .19 Hinged Glass Door .30 .23 Sliding Glass Door .28 .22 Note(s): 1) All hot water lines will be insulated with a minimum of 1 inch insulation. This is in addition to the insulation required by the mandatory requirements per Sec. 150.00)2. 2) The water heater for this house will have a hot water demand type recirculating system with manual control. 3) This house will have a tankless water heater with a uniform energy factor (UEF) of .92 or greater and sized per the owner's specifications. 4) Quality Insulation Installation (QII) is required for this project. Coordinate requirements with the HERS rater prior to beginning construction. Multiple inspections are required during the construction process. You must get approval from the HERS rater prior to drywall. ** SUMMARY SHEET ** Project: 'Lennar Homes -- La Quinta, CA Zone: 15 "Griffin Ranch 2017" Plan 6(4629) Wall Insulation: R-15 in 2x4 Exterior Walls (Quality Insulation Installation) R-21 in 2x6 or Greater Exterior Walls (Quality Insulation Installation) Ceiling Insulation: R-30 with Spray Foam Below Roof Deck for Conditioned Unvented Attic (Quality Insulation Installation) Radiant Foil Barrier: Not Required Cool Roof (CRRC): Required with .16 Min. Aged Reflectance and .89 Min. Aged Emissivity Raised Floor Insulation: N/A Solar PV: Not Required Whole House Fan: Not Required Minimum Furnace AFUE: House = 92% AFUE Low Leakage Furnace to be Rater Verified Casita = 8.2 HSPF (Heat/Pump) Minimum Heating Capacity: House = 49,374 BTUH Casita = 7,257 BTUH Minimum A/C SEER: House = 14.0 SEER/12.0 EER Rater Verified Casita = 14.0 SEER/11.0 EER Adequate Cooling Coil Airflow to be Rater Verified Fan Watt Draw to be Rater Verified Refrigerant Charge Test to be Rater Verified A/C Tonnage: House = 58,717 @ 1150 Min.Sens. (A/C Size By Mechanical Contractor) Casita = 6,106 @ 1150 Min.Sens. (A/C Size By Mechanical Contractor) Duct Insulation: R-6.0 For Ducts & Plenums ALL in Conditioned Spaces Duct Leakage Test Required Glazing: All fenestration will have dual pane Low-E glass and the following maximum NFRC values: U-factor SHGC U-factor SHGC Operable .30 .23 Stacking Glass Door .32 .20 Fixed .26 .25 Folding Window .32 .19 Hinged Glass Door .30 .23 Sliding Glass Door .28 .22 Note(s): 1) All hot water lines will be insulated with a minimum of 1 inch insulation. This is in addition to the insulation required by the mandatory requirements per Sec. 150.00)2 2) The water heater for this house will have a hot water demand type recirculating system with manual control. 3) This house will have a tankless water heater with a uniform energy factor (UEF) of .92 or greater and sized per the owner's specifications. 4) Quality Insulation Installation (QII) is required for this project. Coordinate requirements with the HERS rater prior to beginning construction. Multiple inspections are required during the construction process. You must get approval from the HERS rater prior to drywall. El ** SUMMARY SHEET ** Proiect• Lennar Homes -- La Quinta. CA _ Zone:. 15 "Griffin Ranch 2017" Plan 7 4700 Wall Insulation: R-15 in 2x4 Exterior Walls (Quality Insulation Installation) R-21 in 2x6 or Greater Exterior Walls (Quality Insulation Installation) Ceiling Insulation: R-30 with Spray Foam Below Roof Deck for Conditioned Unvented Attic (Quality Insulation Installation) Radiant Foil Barrier: Not Required Cool Roof (CRRC): Required with .16 Min. Aged Reflectance and .89 Min. Aged Emissivity Raised Floor Insulation: N/A Solar PV: Not Required Whole House Fan: Not Required Minimum Furnace AFUE: 92% AFUE Low Leakage Furnace to be Rater Verified Minimum Heating Capacity: 51,556 BTUH Minimum A/C SEER: 14.0 SEER/12.0 EER Rater Verified Adequate Cooling Coil Airflow to be Rater Verified Fan Watt Draw to be Rater Verified Refrigerant Charge Test to be Rater Verified A!C Tonnage: Min.Sens.= 61,760 @ 1150 (A/C Size By Mechanical Contractor) Duct Insulation: R-6.0 For Ducts & Plenums ALL in Conditioned Spaces Duct Leakage Test Required Glazing: All fenestration will have dual pane Low-E glass and the following maximum NFRC values: U-factor SHGC U-factor SHGC Operable .30 .23 Stacking Glass Door .32 .20 Fixed .26 .25 Folding Window .32 .19 Hinged Glass Door .30 .23 Sliding Glass Door .28 .22 Note(s): 1) All hot water lines will be insulated with a minimum of 1 inch insulation. This is in addition to the insulation required by the mandatory requirements per Sec. 150.00)2. 2) The water heater for this house will have a hot water demand type recirculating system with manual control. 3) This house will have a tankless water heater with a uniform energy factor (UEF) of .92 or greater and sized per the owner's specifications. 4) Quality Insulation Installation (QII) is required for this project. Coordinate requirements with the HERS rater prior to beginning construction. Multiple inspections are required during the construction process. You must get approval from the HERS rater prior to drywall. / A ** SUMMARY SHEET ** Project: Lennar Homes La Quinta, CA Zone: 15 "Griffin Ranch 2017" Plan 8(4820) Wall Insulation: R-15 in 2x4 Exterior Walls (Quality Insulation Installation) R-21 in 2x6 or Greater Exterior Walls (Quality Insulation Installation) Ceiling Insulation: R-30 with Spray Foam Below Roof Deck for Conditioned Unvented Attic (Quality Insulation Installation) Radiant Foil Barrier: Not Required Cool Roof (CRRC): Required with .16 Min. Aged Reflectance and .89 Min. Aged Emissivity Raised Floor Insulation: N/A Solar PV: Not Required Whole House Fan: Not Required Minimum Furnace AFUE: 92% AFUE Low Leakage Furnace to be Rater Verified Minimum Heating Capacity: 52,740 BTUH Minimum A/C SEER: 14.0 SEER/12.0 EER Rater Verified Adequate Cooling Coil Airflow to be Rater Verified Fan Watt Draw to be Rater Verified Refrigerant Charge Test to be Rater Verified A/C Tonnage: Min.Sens.= 62,524 @ 1150 (A/C Size By Mechanical Contractor) Duct Insulation: R-6.0 For Ducts & Plenums ALL in Conditioned Spaces Duct Leakage Test Required Glazing: All fenestration will have dual pane Low-E glass and the following maximum NFRC values: U-factor SHGC U-factor SHGC Operable .30 .23 Stacking Glass Door .32 .20 Fixed .26 .25 Folding Window .32 .19 Hinged Glass Door .30 .23 Sliding Glass Door .28 .22 Note(s): 1) All hot water lines will be insulated with a minimum of 1 inch insulation. This is in addition to the insulation required by the mandatory requirements per Sec. 150.00)2. 2) The water heater for this house will have a hot water demand type recirculating system with manual control. 3) This house will have a tankless water heater with a uniform energy factor (UEF) of .92 or greater and sized per the owner's specifications. 4) Quality Insulation Installation (QII) is required for this project. Coordinate requirements with the HERS rater prior to beginning construction. Multiple inspections are required during the construction process. You must get approval from the HERS rater prior to drywall. BUILDING ENERGY ANALYSIS REPORT PROJECT: Lennar Homes - Plan #1(2967) Griffin Ranch 2017 La Quinta, CA Project Designer: Lennar Homes 980 Montecito Drive, #302 Corona, CA 92879 951-817-3600 Report Prepared by: Rick Maurer Rick Maurer Title 24 7544 Saddlehill Trail Orange, CA 92869 714-771-1507 Job Number: Date: 11/18/2017 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software—www.energysoft.com. I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01 -E Certificate of Compliance 3 HVAC System Heating and Cooling Loads Summary 15 EnergyPro 7.2 by EnergySoft Job Number. UJ: User Number. 1686 1 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Grin Ranch 2017 - Plan #1(2967) Calculation Date/Ttme: 14:41. Sat, Nov 18, 2017 Calculation Description: Tile 24 Analysis Input File Name: Lennr400.ribd16x CFI R-PRF-01 Page 1 of 12 GENERAL INFORMATION - - - - 01 - Project Name G4ffin Ranch 2017 - Plan #1(2967) 02 Calculation Description Title 24 Analysis 03 ---- Project Location -Gnffin Ranch 2017 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 07 Compliance Manager Version. BEMCmpMgr 2016.3.0 (934 SP1) 08 Climate Zone CZ15 09 . Software Version EnergyPro 7.2 10 - Building Type Single Family - 11 Front Orientation (deg/Cardinal) Cardinal 12 - Project Scope Newly Constructed - 13 Number of Dwelling Units 1 14 To tat Cond. Floor Area (ft2) 2967 1b Number of Zones 2 16 Slab Area (ft2) 2967 - 17 Number of Stories 1 18 Addition Cond. Floor Arealft2) n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) n/a 21 Glazing Percentage (%) 19.7% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing:ar{d/owe`Oflcaticrl by a clerked Hl RS ratdWnder Co s , jp sloo�of a CEC-approved HERS provider. 03 This building Incorporates one or ov&WSkciai Features'siiown below ' " " "°a I i t.. 1 S n,, I r't ti. a C.., t-.- i i Registration Number:217-P0100249060-000-000-0000000-0000 Registration DateRme: 2017-11-2012:19:35 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11.18 14:42:40 B CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #1(2967) Calculation DateMme: 14:41, Sat, Nov 18, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr400.ribd16x CF1 R-PRF-01 Page 2 of 12 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Pereent (ItTDV/ft",Yri Design Design Margin Improvement Space Heating 1.52 1.66 - -0.14 -9.2% Space Cooling 84.68 e5.67 19.01 22.4% IAQ Ventilation 0.92 0.92 0.00 0.0% Water Heating 4.38 4.09 0.29 6.6% PV Credit - 0.00 0.00 - North Facing Compliance Total 91.50 72.34 19.16 20.9% Space Heating 1.52 2.00 -0.48 -31.6% Space Cooling 84.68 74.27 10.41 12.3% IAQ Ventilation 0.92 0.92 0.00 0.0% Water Heating 4.38 4.09 029 6.6% PV Credit - 0,00 0.00 - East Facing Compliance Total 91.50 81.20 10.22 11.2% Space Heating 1.52 ... 2.12 .o5 -0.60 -39.5% Space Ccoling 68 18.63 22.0% IAQ Ventilation C2 C E " D. lv%c 0.00 0.0% Water Heating 6 09 0.29 8.896 PV Credit t� t '� = E� r t r7 t"3 (-1 a I Ca E R 0.00 - South Facing Compliance Total 91.60 73.18 16.32 20.0% Space Heating 1.52 1.65 -0.33 -21.7% Space Cooling 84.68 70.44 14.24 16.8% IAQ Ventilstion 0.92 0.92 0.00 0.0% Water Heating 4.38 4.09 0.29 6.6% PV Credit - 0.00 0.00 - Wesl Facing Compliance Total 91.50 77.30 14.20 15.5 % Registration Number: 217-P010024e06D-000-DOD-WOOOOD-0000 Registration Datalfime: 2017-11-20 12:19:35 HERS Provider CeICERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-1814:42:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #1(2967) Calculation DateMme: 14:41, Sat, Nov 18, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr400-ribdl6x CF1 R-PRF-01 Page 3 of 12 ENERGY DESIGN RATING Energy Design Rating (EDR) Is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 200E International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" Its TDV energy. Because EDR Includes consideration of components not regulated by Title 24. Part 6 (such as domestic appliances and consumer electronics), it Is not used to show compliance with Part 6 but may Instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design Is provided separately from the EDR value of Installed PV so that the effects of efficiency and renewable onamycan both beseen -EDR or Standard EMciency - EDR-of Proposed Efficiency EDR Value of Proposed PV • Battery Final Proposed EDR North 53.7 - 45.2 0.0 - 45.2 East 63.7 49-2 0.0 49.2 South 53.7 46.6 _ 0.0 45.6 West 53.7 47A 0.0 47.4 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑. Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and Oil verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family In climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) Including on -she photovoltaic IPV) renewable energy generation sufficient to achieve a_Fin Energy Design Rating (EDR) of zero or less. The PV System must be verified. Ia��l Notes: pwy Y. Crz>... r (t ry+4 • Excess PV Generation EDR Credit: Bypassing PV slie ItmR ma vlolate,Net Ener Meterin . NEM rules •tN -..t REQUIRED SPECIAL FEATURES t ' r.- r"-r. ,�•. r 1. a^. -^ r`r The following are features that must be Installed as condition (or melting the modsleA e6crrgy'p0rfermaric¢ for Ihis Wniput0i anotysis. • Non-standard roof reflectance • Window overhangs and/or fins • Non-standard duct location (any location other than attic) • Recirculation with demand control, push button Registration Number 217-P010024606D-0DO-OOD4)000000.0000 Registration DaleRme: 2017-11-20 12:19:35 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2017-11-1814,42:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Grrin Ranch 2017 - Plan #1(2967) Calculation DateTme: 14:41, Sat, Nov 10, 2017 Page 4 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr400.ribdl6x HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided In the building components tables below. Building -level Verifications: • High quality Insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Ducts located entirely In conditioned space confirmed by duct leakage testing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: - None -- BUILDING - FEATURES INFORMATION 01 02 03 04 - 05 06 07 rrNufnber of Dwelling' "ro .# T{ Number of Ventilation Number of Water Project Name. CondRlonedFloor Area (ft2j, r"tipits Kumbgrof.Bedroom4 NumbcDrolZo)plcaf° Cooling Systems Heating Systems Griffin Ranch 2017 - Plan 01(2967) - 2967,t_' ' �z,,_:,,;,1,,.,,,,,,,,R, .�,I �,,. a• tt 2 ft,... n 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Floor Area Avg. Ceiling Zone Name Zone Type HVAC System Name (R2) Height Water Heating System 1 Water Heating System 2 Living Conditioned HVAC - Living1 170D 12 DHW Sys 1 n/a Bedrooms Conditioned HVAC - Bedrooms2 1267 12 DHW Sys 1 n/a Registration Number 217-P0100249060-000-000-0000000-0000 Registration Daternme: 2017-11-20 12:19:35 HERS Provider. CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2017-11-16 14:42.40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 -Plan #1(2967) Calculation Date/Time: 14:41, Sat, Nov 18, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr400.ribdl6x CFI R-FRF-01 Page 6 of 12 OPAQUE SURFACES Ot - 02 03 04 05 06 07 08 _ Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area Ift2) Tilt (deg) Front 2x6 Wall - Living R-21 Wall 0 Front 330 99.6033 BD Left 2x6 Wall Living R-21 Wall . 90 Left 451, 48 90 Back 2x6 Wall Living R-21 Wall... 180 Back 516 262.5 90 Right 2x6 Wall Living- R-21 Wall 270 Right 30 0 90 Front Garage Wall - - Llving»_Garage_ - R-15 Wall House/Garage nia n/a 1 230 21 nia Interior Surface Living»Bedrooms R-0 Wall1 n/a nia 600 - 0 n/a Ceiling Below Attic Living R-30 Attic HPA n/a n/a 1700 n/a n/a Front 20 Wall 2 Bedrooms R-21 Well - 0 Front 140 36 90 Left 2x6Wall 2 Bedrooms R-21Wall. 90 Lett 60 0 90 Back 2x6 Wall 2 Bedrooms _ R-21 Wall 180 Back 352 110 90 Right 2x6 Wall 2 - Bedrooms R-21 Wall 270 Right 550 52 90 Front 2x6 Garage Wall Bedrooms»_Garage_ _ R 21 Wall House/Garage nia n/a 80 0 nia Left Garage Wall Bedrooms» Garage ; .a� ftl§*all HouselGarages ;pia o nNa, r. a 110 0 n/a Calling Below Attic 2 Bolfroorr<s �;., j ��fR, 30 Atfc HPAK I. nle ; Na7 k4 - 1267 n/a n/a FG Wall - _Gargpa= � ,._ ... R:fl YYali, - _„ ,y0., - ._- FroOt �, 279 1 170 90 LG Wall _Garego^E { 1 -R-0 wall i 90 1 Left l 207 0 90 RG Wall _Garage_ R-0 Wall 270 Right 99 0 90 Garage Ceiling !Garage_ R-0 Garage Attic n/a n/a 634 n/a - n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Living Attic RoofLiving Unventilated 3 0.16 D.89 No No Attic Bedrooms Attic RooiBedrooms Unventilated 3 0.16 0.89 No No Attic _Garage_ Attic Garage Roof Cons Ventilated 3 0.16 0.89 - - No No Registration Number: 217-P010024806D-OW-000-D000000-0000 Registration Date/Time: 2017-11.20 12:19:35 HERS Provider. CeICERTs lnc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version-CF1R-09012017-934 SPt Report Generated at 2017-11-1814:42:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #1(2967) Calculation Date/Time: 14:41, Sat, Nov 16. 2017 Page 6 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr400.ribdl6x FENESTRATION f GLAZING 01 -- 02 03 04 05 06 07 08 us 10 Name Type Surface (Orlentatlon-Aidnitrth) Width (ft) Height (ft) Multiplier Area (tt=) U-factor - SHGC Exterior Shading Front Openable Window Front 2x6 Walb(Front-0) 3.0 6.0 1 16.0 0.3D 0.23 Insect Screen (defaut0 Front Operable 2 Window Front 2x6 Wall (Front-0) 4.0 6.0 1 24.0 0,30 0.23 Insect Screen (default) Front Operable 3 Window Frond 2x6 Wall (Front-0) _ 3.0 6.0 1 18.0 0.30 0.23 Insect Screen (default) Front Fixed Window Front 2x6 Wall (Front-0) 2.3 6.7 1,_004 15.6 0.26 0.25 Insect Screen (default) Left Openable Window Left 2x6 Wall (Left-90) - - 1 24.0 0.30 0.23 Insect Screen (default) Left Openable 2 Window Left 2x6 Wall (Left-90) 4.0 6.0 1 24.0 0,30 0.23 Insect Screen (default) Back Stacking Glass Door Window Back 2x6 Wall (Back-180) 24.0 10.0 1 240.0 0.32 0,20 Insect Screen (default) Back Fixed Window Beck 2x6 Wall (Back-180). 3.0 1.5 1 4.5 -. 0.26 0.25 Insect Screen (default) Back Openable Window Back 2x6 Wall (Back-1 60) 3.0 6.0 1 1&0 0.30 0.23 Insect Screen (default) Front Openable 4 Window Front 2x6 Wall 2 (I'MM-0) 6.0 6.0 1 36.0 0.30 0.23 Insect Screen (default) Back Fixed 2 Window Back 24 Wag 2 (Back-180) -- - 1 15.0... 0.26 0.25 Insect Screen (default) Back Fixed 3 Wndow eadfr Wat12(88cK-%b) ' 10A'i"! `,"1.6 - 1 _15.0 0.26 0.25 - Insect Screen (default) Bach Sliding Glass Door Window 84 2x6 Wag § (Baokr 80) ' f -4,104, . 'qi;&o Vi �A. ( 80.0 0.28 0.22 Insect Screen (default) Right Openable VNndow `t Rlgry't�is+fi^aU3(12fgh°270) ' 1 t6.11't 1 60 N 1 40�36.b 0.30 0,23 Insect Screen (default) Right Openable 2 Window - '';k Right>4 Wall2 (Qhl47,0). }^-f 1 2A..„ fd.0,. ,,,i 9T" ->R 8.0 0.30 0.23 Insect Screen (default) Right Openable 3 - Window Right 2x6 Wall 2 (Right-270) 20 4.0 1 8.0 0.30. 0.23 Insect Screen (default) OPAQUE DOORS 01 02 ._ 03 - 04 Name Side of Building Area (ft) U-factor Front Door Front 2x6 Wall 24.0 - 0.50 Front Gara ge Door Front Garage Wall 21.0 0.50 Car Door FG Wail 170.0 0.50 Registration Number. 217-P0100248060-000-000-0000000-0000 Registration DaleTme: 2017-11-20 12:19:35 HERS Provider. CeIGERTS inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2017.11-18 14:42:40 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #1(2967) Calculation Datemme: 14:41, Sat, Nov 18, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr400.ribd16x CF1R-PRF-01 Page 7 of 12 OVERHANGS AND FINS 01 02 03 04 06 06 07 08 09 1 16 11 12 13 J 14 Overhang Left Fin - Right Fin- Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bet Up :Depth Top Up Dist R Bat Up Front Openable 1.5 4 2 2 0 0 0 0 0 0 D 0 0 Front Openable 2 4.7 1 2 - 2 0 0 0 0 D 0 0 0. 0 Front Openable 3 4.7 1 2 2 0 0 0 0 0 0 0 0 - 0 Front Fixed 7.5 0 2 2 0 0 0 0 0 - 0 0 0 0 Left Openable 2 4 1 2 2 0 0 0 0 0 0 0 0 0 Back Stacking Glass Door 10.3 1 2 2 0 0 0 0 D 0 0 0 6 Back Fixed 10.3. 1 2 2 - 0 0 0 0 0 0 0 0 0 Back Operable 10.3 3 2, 2 0 0 D 0 0 0 0- 0 0 Front Operable 4 1_ 0.3 2. 2 0 0 0 ...0 0 0 0 0 0 Back Fixed 3 10.3 1 2 2 0 0 0 0 0 0 0 0 0 Back Sliding Glass Door 10.3 3 ,r4� 2 I to" O as I Rai" Li" +0 0 0 0 0 0 0 Right Opdnablo. 1.5 6_ 2 2 Cam.. '"' 0, ' 0`elt 01 1 1 C 0 0 0 0 - 0 Right Openable 2 1.5 ' ry„ 2 0* 2' 1' 11 � +v0` ,t,�.. 0 4� ; F 05 1 110!! rt 3t 0 0 0 0 -. 0 ..RightOperable 3 1.5 42. t .2. r- '2'a, - .0 x (0 ti` j cl i �- Oh D 0 0 0 0 Registration Number: 217_P010024806D-000.000-t1000000-0000 Registration Date✓Yme: 2017-11-2012 19:35 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1R-09012017-934 SPt Report Generated at: 2017-11.18 14:42:40 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Griffin Ranch 2017 - Plan #1(2967) Calculation DatefTime: 14:41. Sat, Nov 18, 2017 Page 8 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr4o0.dbdl6x OPAQUE SURFACE CONSTRUCTIONS - o1 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers Ceilings (below • Inside Finish: Gypsum Board R-0 Garage Attic attic) Wood Framed Ceiling : 2x4 @ 24 in. O.C. none 0,481 Cavity/Frame: no insul. /2x4 Inside Finish: Gypsum Board • Cavity/Frame: noinsul./2x4 R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 In. O.C. none 0.361 ExtedorFinish: 3 Coat Stucco • Cavity/ Frame: no insul. / 2x4 Top Chrd • Roof Deck., Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling In. O.C. none 0.400 Roofing: 10 PSF (Rooffile) '• Around Roof Joists. R-17.0 insul.. • Cavity/Frame:R-13.0/2x4Top Chrd • Roof Deck., Wood Siding/sheathing/deckng 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic RoofUving Attic Roofs Wood Framed Ceiling In, O•C, R 30 0.040 Roofing., 10 PSF (Rodffile) Ceilings (below ,,. Inside Finish: Gypsum Board R-30 Attic HPA attic) _, _ Wood Fmmed Ceiling , :.r 2x4 d 24 in 0 C `i;! none, 0.481 Cavity/frame: no Insul. /2x4 4a r 2r �,', Inside Finish: Gypsum Board R-21 Wall Exterior Walls `Wood Framed Wall v 2x6 @ 16 in O C. .ab`t e R 21..,, ,.0.069 Cavify/F2me: R-21 /2x6 Exterior Finish: 3 Coat Stucco • '- ° `• ' `'` '"' ` Inside Finish: Gypsum Board • Cavity/Frame: R-15/2x4 R-15 Wall House/Garage Interior Wags Wood Framed Wall 2x4 @ 16 in. O.C. R 15 0,086 Other Side Finish: Gypsum Board • Inside Finish: Gypsum Board j - Covity/Frame: no insul. /2x4 R-0 Wahl Interior Walls Wood Framed Wall 2x4 @ 16 In. D.C. none 0.277 Other Side Finish: Gypsum Board Around Roof Joists: R-17.0lnsul. • Cavily/Freme: R-13.0/2x4 Top Chrd • Roof Deck. Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic RoofBedrooms j Attic Roofs Wood Framed Ceiling In. O.C. R 30 0.040 Roofing: 10 PSF (R-Mle) Inside Finish: Gypsum Board • Cavity/Frame: R-21/2x6 R-21 Wall House/Garage Interior Walls Wood Framed Wall 24 @ 16 In. O.C. R 21 0.064 Other Side finish: Gypsum Board Registration Number: 217-P01oM46060-000-000-0000000-0000 Registration OateMme: 2017-11-20 12:10:35 HERS Provider. CeICERTS Inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2017-11-1814:42:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #1(2967) Calculation DateMme: 14:41, Sat, Nov 18, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr400.ribdl6x CFI R-PRF-01 Page 9 of 12 SLAB FLOORS 01 02 03 04 05 _ 06 07 Name Zone Area (It') Perimeter (ft) Edge Insul. R-value a Depth Carpeted Fraction Heated Slab -on -Grade Living 1700 117 _ None 0.8 No Slab -on -Grade 2 Bedrooms 1267 107 None 0.8 No Garage Slab _Garage_ 634 ' 65 None 0 No BUILDING ENVELOPE - HERS VERIFICATION D1 02 03 04 Quality Insulation installation (Qil) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS - 01 02 03 04 OS 06 Name - System Type Distribution Type Water Heater Number of Heaters, Solar Fraction (R) DHW Sys 1 DHW Reclrculation with demand control, J .Vpushpufton�, e+epe+ DHW HeQater 1 (1) l Q"c. 6: 1 .0% WATER HEATERS 01- _ - 02 OJ ` , 05 �-. 06 - .. 07 y . 1a08 _ 09..,. 10 11 .. .. 12 Name Heater Element Type Tank Type Number of Units i-1 Tank Volume (gal) n J •C Y Uniform Energy Factor I Energy Factor I Efficiency InPURafing'I Pilot I Thermal Efficiency V Tankt_J Insulation R-value (InVEat) i:Starid6y Loss I Recovery Eff First Hour Rating I Flow Rate NEEA Heat Pump Brand I Model Tank Location or Amblent Condition DHW Heater 1 _ Gas Consumer Instantaneous (UEF) 1 0 0.92 UEF 199,900 Blulhr 0 n/a 10 GPM n/a nla SPACE CONDITIONING SYSTEMS 01 02 03 04 OS 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC - Llvingl Other Healing and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - Bedrooms2 Other Healing and Cooling System Healing Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 Registration Number: 217-POI0024606D-000-000-0000000.0000 Registration DateRme: 2017-11-20 12:19:35 HERS Provider. CeICERTS Inc,: CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version-CF1R-09012017.934 SP1 Report Generated at 2017-11-18 14:42:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Gruen Ranch 2017 -Plan #1(2967) Calculation DateTme: 14:41, Sat, Nov 18, 2017 Calculation Description: Tile 24 Analysis Input File Name: Lennr400.ribdl6x CF1 R-PRF-01 Page 10 of 12 HVAC - HEATING UNIT TYPES 01 - 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 - CntdFumece 1 92 AFUE Healing Component 2 CnldFurnace 1 92 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification CoolingComponent 1 po S IitAlrCond P 1 12 14 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 1 12 14 Zonally Controlled Single Speed Cooling Component 2-hers-cool .HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name fit' 'VertfiedAirtlow: ..+ t4 .tr 'M k 1! iowTarget;a. ,Vcrified,F,ERR1 ir y, Verified SEER Verified Refrigerant Charge Cooling Component 1alers-cool `fi2atiuired '" K VbO k ii350' «t 'Z It W'e999 }72eq&ed' V Not Required Required C0o0ng Component 2-hers-cool RogGtii d # »1 j 274' > 1-� C Q0g6ked F [— Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 - 06 07 Name Type Dud Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctslnAll Specified Lower Leakage Target 6 Conditioned zone None Air Distribution ttiionnl System Air Distribution System 2 DuctslnAll Specified Lower Leakage Target 6 Conditioned zone None Air Distribution System 2 hers�Sist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 OS Name Duct Leakage Verification Duet Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Duets Low -leakage Air Handler Air Distribution System 1-hers-dist Required 5.0 Required Not Required Not Required Not Required Required Air Distribution System 2-hers-dist Required 5.0 Required Not Required Not Required Not Required Required Registration Number 217-Po10024806D-OM000-0000000-DODO Registration DateMme: 2017-11-20 12:19:35 HERS Provider: CeICERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version-CF1R-o9012017-934 SP1 Report Generated at: 2017-11-18 14:42:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #1(2967) Calculation DaterTime: 14:41, Sat, Nov 18, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr400.ribdl6x CF1R-PRF-01 Page 11 of 12 HVAC-FAN SYSTEMS 01 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Spded PSC Furnace Fan - 0.58 HVAC Fan 1-hers-fen HVAC Fan 2 Single Speed PSC Fumace Fan 0.58 HVAC Fan 2-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION Name Verified Fan Watt Draw Required Fan Elficlency (W®Us/CFM) HVAC Fan 1-hers-fan Required - 0.58 HVAC Fan 2-hers-fan Required 0.58 IAQ (indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 60 ,AWAI t; r.++�+ a0:?5 n - —P-- A '= Default 0 - Required Registration Number: 217-P010024806D-000-000.0000000-0000 Registration Daternme: 2017-11-20 12:19:35 HERS Provider. CBICERTS be, CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-034 SP1 Report Generated at: 2017-11-16 14:42:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #1(2967) Calculation Dateff ime: 14:41, Sat, Nov 18, 2017 Page 12 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr400.ribd16x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signatui Rick Maurer Company: - Rick Maurer Title 24, Inc. Signature Date: 2017-11-20 12:18:54 /`/^► R,,��''ff Address: 7544 Saddlehill Trail CEA/HERS Certification Identification (If appllcahi��"tlr R13-90-10024 City/SlaterZip: - - - Phone: Orange, CA 92869 714-771-1507 RESPONSIBLE PERSON'S DECLARATION STATEMENT certify the following under penally of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24. Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features Identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to titer onforcementagancy)orappmval_�yttii lMs;building petmit application. Responsible Designer Name: €, „ ., Responsible Vastgnar Srg tUiO}- James Jenike - Company: DattQS'ned: 20``171-2012.1t9:S5 1 Lennar Homes -Southern CA Address: License: 980 Montecito Drive, Suite 302 City/State/Zip: Phone: Corona, CA 92879 951-817-3500 Digitallysigned byCalCEATS, This digital signature is provided in order to secure the content of this registered document and in noway implies Registration a Provider responsibility for the accuracy of the information. Easy to Verify at CaICERTS.com Registration Number 217-P010)248061)-000-000-0000000-0000 Registration DateMme: 20117-11-2012:19:35 HERS Provider. CeICERTS he. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version- CF1R-09012017-934 SP1 Report Generated at: 2017-11-18 14:42:40 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - Plan #1(2967) Date 11/18/2017 System Name HVAC - Living Floor Area 1,700 ENGINEERING CHECKS" SYSTEM LOAD Number of Systems 1 COIL CFM. Total Room Loads 1,021 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK S stem Sensible , Latent. CFM Sensible -Heating. Output perSystem 64,000 21,553 2.2871 468 18,390 Total Output Btuh 64,000 0 Output Btuh/s ft 37.6 334 227 System 0 0 -Cooling Output perSystem 48,000 0 0 0 0 Total Output Btuh 48,000 0 334 1 22,220 2,287 0 Total Output Tons 4•0 227 Total Output Btuhls ft 28.2 Total Output s f rron 425.0 1 18,844 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Liv.HVAC Equipment Selection & Sizing by Others 30,843 9,724 64.000 Airflow cfmis ft 1.18 64,000 I Jan 1 AM Airflow cfmrTon 500.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 30,843 9;724 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions _ Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 68 OF 105 OF -- Outside Air 0 cfm Supply Fan Heating Coil 2,000 cfm 68 OF 105 OF ROOM 68 IF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF 75/62°F 75/62°F 55/54°F --►--.� 0' ; --1► �' Outside Air �J--� 0 cfm Supply Fan Cooling Coil 2,000 cfm 75 / 62 OF 4 =w I Ea 55 ! 54 OF 47.5% Y ROOM M 75162 IF EnergyPro 7.2 by EnergySoft User Number: 1686 ID: Page 15 of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - Plan #1(2967) Date 11/18/2017 System Name HVAC - Bedrooms Floor Area 1,267 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 733 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 48,000 15,471 1,7051 337 13,236 Total Output Btuh 48,000 0 Output Btuhls ft 37.9 240 163 Cooling System 0 0 Output perSystem 36,000 0 0 0 0 Total Output Btuh 36,000 0 240 1 15,950 1,705 0 Total Out ut Tons 3.0 163 Total Output BtLh/s ft - 28.4 Total Output s ft/Ton 422•3 13,563 Air System CFM perSystem 1.400 HVAC EQUIPMENT SELECTION Airflow cfm 1,400 Bed.HVAC Equipment Selection & Sizing by Others 23,569 6,869 48,000 Airflow cfm/s ft 1.10 Airflow cfmrron 466.7 Outside Air % 0•0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 23,569 6,869 1 48,000 I Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 26 IF 68 OF 68 OF 105 OF Outside Air 0 cfm Supply Fan Heating Coil 1,400 cfm 68 OF ll 21—F 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112178 OF 75 ! 62 OF 75 / 62 OF 55154 IF UTEOutside Air 0 cfm Supply Fan Cooling Coil 1,400 cfm 75 / 62 of LEEI � 55 / 54 OF '- 47.6% ROOM 75 i 62 OF EnergyPio 7.2 by EnerrySoff User Number: 1686 /D: Page 16 of 16 BUILDING ENERGY ANALYSIS REPORT PROJECT: Lennar Homes - Plan #1X(3271) Griffin Ranch 2017 La Quinta, CA Project Designer: Lennar Homes 980 Montecito Drive, #302 Corona, CA 92879 951-817-3600 Report Prepared by: Rick Maurer Rick Maurer Title 24 7544 Saddlehill Trail Orange, CA 92869 714-771-1507 Job Number: Date: 11 /18/2017 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software—www.energysoft.com. TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 HVAC System Heating and Cooling Loads Summary 16 EnergyPro 7 2 byErtergySoft Job Number ID: User Number. 1686 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #1X(3271) Calculation Daterrime: 14:37, Sat, Nov 18, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr401.ribdl6x CFI R-PRF-01 Pagel of 13 GENERAL INFORMATION . 01 - Project Name Griffin Ranch 2017- Plan #1X(3271) , 02 Calculation Description Tifie 24 Analysts 03 Project Location Griffin Ranch 2017 04 City La Quinta - os Standards Version Compliance 2017 -06 Zip Code - - 07 Compliance Manager Version BEMCmWgr 2016.3.0 (934 SP11) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 - Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area(ft) 3271 1s - Number of Zones 3. 16 Slab Area (111) 3271 17 Number of Stories I 19 Addition Cond. Floor Arca(ttz) nla 19 Natural Gas Available Yes 20 Addition Slab Area.(R1) Ma. 21 Glazing Percentage (%) 20.1% COMPLIANCE RESULTS .. 01 G Budding Complies with Computer Performance 02 This building incorporates features That Fagtiiro Ile�d }estingand/o veilfiwporf a ea`t 4pd HERS ratot-ureder ttte siipei it(in of a CEC-approved HERS provider. 03 ,++r,— v"r ,g i.. s: -4ae1 M This building Incorporatesone or m'Sjiadai Featuiti6 snot"vi1 hiflow " - . z 2 F k ,.i t 1 . . ,er e , — , , , Registration Number: 217-P010024938D-000-000-0000000-0000 Registration DaterTme: 2017-11-2012:19:37 HERS Provider, CaICERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at; 2017-11-1814,38:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #1X(3271) Calculation Date/Time: 14:37, Sat, Nov 18, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr401.ribdl6x CFIR-PRF-01 Page 2 of 13 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV1ftkyr) Design Design Margin improvement Space Heating 1.91 2.18 -0.27 -14.1% Space Cooling 88.27 71.54 16.73 19.0% IAO Ventilation 0.99 0.99 0.00 0.0% Water Heating 4.35 4.07 028 6.4% PV Credit - 0.00 0.00 - North Facing Compliance Total 95.52 78.78 16.74 11.5% Space Heating 1.91 2.58 -0.67 -35.1% Space Cooling 60.27 81.06 7.21 8.29A IAQ Ventilation 0.99 0.99 0.00 0.0% Water Heating 4.35 4.07 0.28 6.4% PV Credit - 0.00 0.00 - EastFacing Compliance Total 95.52 88.70 6.82 7.1% Space Heating 1.91 2,70 ' -0.79 -41.4% Cooling IAO Ventilation Ca97 i T n p 0.0Space Water Heating a �( . 26 PV Credit tt �-'j 1��> r f_ 0.00 L�.? i� ¢1 0.00 -. South Facing Compliance Total 95.52 79.61 16.91 16.7% Space Heeling 1.91 2.45 -0.54 -28.3% Space Cooling 88.27 77.21 11.06 12.59A IHQ Ventila don 0.99 0.99 0.00 0.0% Water Heating 4.35 4.07 0.28 6.4% PV Credit 0.00 0.00 - West Facing Compliance Total 95.52 84.72 10.80 11.3% Registration Number. 217-P010024838D-M-0004MOo9oo-0Wo Registration DateMme: 2017-11-20 12:19:37 HERS Provider. CaICERTS Ma CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFI R-09012017-934 SP1 Report Generated at: 2017-114814:38:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #1X(3271) Calculation DateMme: 14:37, Sat, Nov 18. 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr401.ribdl6x CF1 R-PRF-01 Page 3 of 13 ENERGY DESIGN RATING Energy,Design.Rating (EDR). is an alternate way to express the energy performance ofa building using a seo ing system where 100 represents the energy performance of the Residential Energy Conservatio» Code (IECC) with California modeling assumptions. A score. of zero represents Energy Sondes (RESNET) reference home ehsracteri tatfon of the 2006 international the energy performance of a bunding that combines high levels of energy efficiency with renewable generation to"zoro out" its TpV energy. Becouse.EDR.includes consideration of Instead by cornponenis.not regulated by Title 24, Part 6 (such as dements appliances and consumorelectronics), It Is not used to show compliance with Part but may be used local jurisdictions.pursuing local ordinances underTiile 24, Part 11 (CALGreen). As a Standard Design building underthe 2016 Bulidtng Eriergy.EKaioncy Standards is sign rmcantly more.eH[ciant than the baseline SUR building, the EDR of Uie.StandardPesignbuilding Is pn: vided /cr Information, Similarly, the:EDR score of the Proposed Design is provided separately from the EDR value of Installed PV so that the effects Ot of icicncy'and renewable energy can both be icon EDR of Standard Efficiency EDR of Proposed Efficiency Value of Proposed PV r Battery Final Proposed EDR North 64.4 47.2 0.0 47.2 East 54.4 61.4 _ 0.0 61A South _ 54.4 47.6 0.0 47.6 West 54.4 49.7 0.0 49.7 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin,(CALGreen A4.203.1.2.2) and QII verification prerequisite. Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family In climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) Including on -site photovoltaic (PV) renewable energy generation sufficient to.achlevo a Fin Energ4`y Design Rating (EDR) of zero or less. The PV System must be verified. ...._ {ail Notes: • Excess PV Generation:SUR Credit: Bypassing Pv site limit vlotato:Not Sitergy Matorin EM rules + j+ REQUIRED SPECIAL FEATURES _ M 3 The following are features that must be installed as condition for maeling the rnopetotl etic'rgy perf*brmat(co_t A1- computer anafySls: • Non-standard roof reflectance • Window overhangs andlor fins • Nonstandard duct location (any location other than attic) • Recirculation with demand control, push button Registration Number. 217-P010024e38D•000-000.0000000-0000 Registration DatelTme: 2017-11-2012:19:37 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version-CF1R-09012017934 SP1 HERS Provider: CaICERTS Inc. Report Generated at 2017-11-18 14:38:26 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Gruen Ranch 2017 - Plan #1X(3271) Calculation Daterrime: 14:37, Sat, Nov 18, 2017 Page 4 of 13 Calculation Description: Tt0e 24 Analysis Input File Name: Lennr401.ribdl6x HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a Certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail Is provided In the building components tables below. Building -level Verifications: • High quality insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications:: • Minimum Airflow • Verified EER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Duds located entirely In conditioned space confirmed by duct leakage testing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: —None— BUILDING - FEATURES INFORMATION 01 02 03 04 05. - 06 07 4Number of (lwelgngr 9$, 11 ;f"* Xrx r Number of Ventilation Number of Water Project Name Conditioned FloorArea(n" v"Unit-' Nulnberofeoodporns , Numtmr,ofZones,- Cooling Systems Heating Systems Griffin Ranch 2017 -Plan 32 A Vc r+ '- 1 ' , a- , 14 R ++r. ! 3* At 0 0 1 N1X(3271f - ZONE INFORMATION 01 02 03 04 OS 06 07 Zone Floor Area Avg. Ceiling Zone Name Zone Type HVAC System Name (ft2) Height Water Heating System 1 Water Heating System 2 Living Conditioned HVAC - Livingt 1700 12 DHW Sys.1 nla Casita Conditioned HVAC -Casita2 304- 9 DHW Sys 1 nla Bedrooms Conditioned HVAC - Bedrooms3 1 1267 12 DHW Sys 1 nla Registration Number: 217-P010044836D-OOD-000-OD000OO-GOOD Registration Date/Time: 2017-11-2012:19:37 HERS Provider. CaICERTS Inc. CA Building Energy Effidency Standards- 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2017-11-18 14:38:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #1X(3271) Calculation Date/Time: 14:37, Sat, Nov 18, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr401.ribdl6x CF1R-PRF-01 Page 5 of 13 OPAQUESURFACES _ - . 01 _ 02 03 - - 04. p5 - 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (11:2) Window 8 Door Area (ft2) Tilt (deg) Front 2x6 Wall Living R-21 Wall 0 Front 330 99.6033 90 Left 2x6 Wall Living R-21 Wall 90 Left 451 48 90 Back 2x6 Wall Living R-21 Wall - 180 Back 516 262.5 - 90 Right 2x6 Wall Living R-21 Wall 270 Right 30 0 - 90 Front Garage Wall Luting»_Garage - R-15 Wall House/Garage n/a Na 230 21 Na Interior Surface Living»Casita R-0 Wall n1a n1a - - 30 0 Na Interior Surface 2 Living»Bedrooms R-0 Wall n1a n1a 600 0 n/a Ceiling Below Attic Living R-30 Attic HPA Na n/a 1700 Na n/a Front Wag Castle R-15 Wall 0 Front 180 24 90 Left Wall Casita - - R-15 Wall 90 Left 112 8 90 Left 2x6 Wall 2 Casita R-21 Wall 90 Left 23 0 90 .. Back Wag Casita R-15 Wall 180 Back 180 40 90 Right Walt _ 'Casgn � QF R-1.5y" ;!) _ WO 4 09ht ,,s v 135 0 90 Ceiling Below Attic 2 ;,CAA, � � —1 1 -tR730 Atkr HPAIk � � nia ,; ;j rfnfo �j, 304 Na Na Front 2x6 Wall 2 8e ioglils _ __ _ R 21Wa>(,,,, D; P. Frorlt 140 36 90 Left 2x6 Wall a -Badroom"s�' € - 1 — t R-21 Wall - I � �'' 96 t 60 - 0 90 Back 2x6Wall 2 - - Bedrooms R-21Wall 1110 Back 352 110 90 Right 2x6Wall 2 Bedrooms R-21 Wall 270 Right 550 52 90 Front 2x6 Garage Wall sedrooms-o Garage R-21 Wall House/Garage Na n/a 8o 0 n/a Left Garage Well Bedrooms»_Garage: R-15 Wall House/Garage Na n/a 110 0 n/a Ceiling Below Attic 3 - Bedrooms . R-30 Attic HPA Na n/a 1267 n/a n/a FG Wall _Garago_ R-0 Wall 0 Front 279 170 90 LG Wall _GOregp_ R-0 Wall 90 - Left 207 0 90 RG Wall _Garage_ R-0 Wall 270 Right 99 0 90 Garage Ceiling tGarage_ R-0 Garage Attic Na Na 634 Na Na Registration Number: 217-P01002463BD-000-000-0000000-0000 Registration DateRme: 2017-11-2012:19:37 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-09012017-934 SP1 HERS Provider: CaICERTS tnc. Report Generated at: 2017-11-18 14:3826 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #1X(3271) Calculation DaterTme: 14:37, Sat, Nov 18. 2017 Calculation Description: Tile 24 Analysis Input File Name: Lennr401.ribd16x CF1R-PRF-01 Page 6 of 13 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emtttance Radiant Barrier Cod Roof Attic Living Attic RoofLiving - Unventilated 3 0.16 0.89 No No Attic Casita Attic RoofCasila Unventilated 3 0.16 0.89 No No Attic Bedrooms Attic Roofl3edrooms Unventilated 3 - - 0.16 0.89 No No Attic Garage_ Attic Garage Roof Cons Ventilated 3 0.16 0.89 1 No No FENESTRATION r GLAZING 01 02 03 04 05 06 07 08 09 10 Name ... Type Surface (Orientation -Azimuth) Width(R) Height (ft) Muftlplier Aroa (flz) U-factor SHGC Exterior Shading Front Openable Front Openable 2 Window Wndow Front 2x6 Wall (Front-0) Front 2x6 Wail (Front-0) 3.0 4.0 6.0 6.0 1 1 18.0 24.0 0.30 0.30 0.23 0.23 Insect Screen (default) Insect Screen (default) Front Openable 3 Front Fixed Window Window Front 2x6 Wail (Front-0) � !di r- F,ton72x6 ',Wall. (F,ta t-0 3.0 � T3 I 6.0 6.7 1 1.004 18.0 18.6 ... 0.3o 0.26 0.23 0.25 Insect Screen (default) insect Screen (default) Leff Openable Window ;, ( eft 2x6 Well ji ev 0) .x� lr q -rr r �f F'1 ( 24.0 0.30 0.23 Insect Screen (default) Left Openable 2 Window " �• - LeiF3it'Mll {Cott-90'4" tea a '4A'' ' 6 1 * 1 x '2 0 0.30 0.23 Insect Screen (default) Back Slacking Glass Door Back Fixed Window Window " ;Bedl'2x6V1'el)(l ack-18 1 Back 2x6 Wall (Back 1 0). 0 4'.0 _ 3.0 4.P10.4 1.5 J 1, :'. 1 �240.0 4.5 0.32 0.26 0.20 0.25 Insect Screen (default) - Insect Screen (default) Back Openable Front Openable 4 Left Openable 3 Wndow Window Wndow Back 2x6 Wall (Back-180). Front Wall (Front-0) Left Wall (Lett-90) 3.0 4.0 - 6.0 6.0 - 1 1 1 18.0 24.0 8.0 0.30 0.30 0.30 0.23 0.23 0.23 Insect Screen (default) Insect Screen (default) Insect Screen (default), Back Hinged Glass Door Wndow Back Wall (Back-180) - - 1. 40.0 0.30 0.23 insect Screen (default) Front Openable 5 Wndow Front 2x6 Wall 2 (Front-0) 6.0 6.0 1 36.0 0.30 0.23 Insect Screen (default) Back Fixed 2 Window Back 2x6 Wall 2(BUC080) - - 1 15.0 0.25 0.25 Insect Screen (default) Back Fixed 3 Wndow Back 2x6 Wall 2 (Back-160) 10.0 1.5 1 15.0 0.26 - 0.25 Insect Screen (default) Back Sliding Glass Door Right Openable Right Openable 2 - Wndow Wndow Window Back 2x6 Wall 2 (Back-180) Right 2x6 Wall 2 (Right-270) Right 24 Wall 2 (Witil370). 10.0 6.0 2.0 8.0 6.0 4.0 1 1 - 1 80.0 36.0 8.0 0.28 0.30 0.30 0.22 0.23 0.23 Insect Screen (default) Insect Screen (default) Insect Screen (default) Right Openable 3 Wndow Right 2x6 Wall 2 (Right-270) 2.0 4.0 1 8.0 0.30 0,23 1 Insect Screen (default) Registration Number. 217-P0100248380.000-00011000000-0000 Registration DateMme: 2017-11-2012:19:37 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards -2016 Residential Compriance Report Version - C F1 R-09012D1 7-934 SPt Report Generated at: 2017-11-18 14:38:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #1X(3271) Calculation DatefTme: 14:37, Sat, Nov 16, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr401.ribdl6x C F7 R-PRF-01 Page 7 of 13 OPAQUE DOORS _...01 02 - 03 04 Name Side of Building Area (t12) U-factor Front Door Front 2x6 Wall - - 24.0 0.50 Front Garage Door Front Garage Wall 21.0 0.50 Car Door FG Wall 170.0 0.50 OVERHANGS AND FINS' 01 02 03 04 0s 08 07 08 09 10 11- 12 13 14 Overhang Left Fin Right Fin Window .- Depth Dist Up Left Extent Right Extent Flap Ht..LDept,hTop Up _. Dist L Bot Up Depth Top Up Dist R Bot Up Front Openable 1.5 4 2 2 0 0 0 0 0 0 0 0 Front Openable 2 4.7 1 ..2 - 2 0 0 0 0 0 0 0 0 Front Openable 3 4.7 1 2 2 0 0 0 0 0. 0 0 0 Front Fixed .. 7.5 0 _-2 ,•. 2..�_ ._ _.0.. .� 0_ 0 0 0 0 0 0 Left Openable 2 4 1 22. 4.0.tl. 0, f 9.+r 0 0 0 - 0 D Back Stacking Glass Door 10.3 1 `� 2i ? - i4 12, 61: 0 } b. ,..: a. 0 D D 0 0 Back Fixed 10.3 ***?o 2 ,�.. — 2 r0 ,..� •0., , _. 'Q_.,, _ �» 0 0 0 0 0 0 Back Openable 10.3 3 '2 '-' ' '2 •' ' 0 ' `-'p r 0"' '"" D1 0 0 0 0 0 Front Openable 4 2 0.3 2 2 0 0 0 0 0 0 0 0 0 Front Openable 5 1 0.3 2 2 0 0 0 0 0 0 0 0 0- Back Fixed 3 10.3 1 2 2 0 0 0 0 0 0 0 0 0 Back Sliding Glass Door 10.3 3 2 2 0 0 0 0 0 0 0 0 0 Right Openable 1.5 2 2 2 0 0 0 0 0 0 0 0 0 Right Operable 2 1.5 2 2 2 0 0 0 0 0 0 0 _ 0 0 Right Opannblo 3 1.5 2 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 217.P010024838DA00-00"000000-0000 Registration DateRme: 2017-11-2012:19:37 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-18 14:38:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #IX(3271) Calculation DateMme: 14:37, Sat, Nov 18, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr401.ribd16x CFI R-PRF-01 Page 8 of 13 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity - Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers Ceilings (below Inside Finish: Gypsum Board R-0 Garage Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: no insul. /2x4 • Inside Finish: Gypsum Board • Cavity/Frame: noinsul. /2x4 R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.361 Exterior Finish: 3 Coal Stucco • Cavity/Frame., no insul. /2x4 Top ChM • Roof Deck: Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic Garage Root Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.400 Roofing: 10 PSF (Rgoffre) • Around Roof Joists: R-17.01nsul. • Cavity/Frame:R-13.0/2x4Top ChM Roof Deck., Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic RoolLiving Attic Roofs - Wood Framed Ceiling in. O.C. R 30 0.040 Roofing., 10 PSF (Rpofrilef, Ceilings (below -� Inside Finish: Gypsum Board R-0O Attic HPA attic) Wood Frarrig-Ming- ;,.0—t 4. @-24 in."f7.C..;. i �o�p•) • „ , -0 A81 Caw7y/Frame: no insul. /2x4 �1'..!t %•�+ t�rrr.. It �:, '1 ax Inside Finish: Gypsum Board Cavity/Frame:R-21/2x6 R-21 Wall < Exterior Wells �,'#?�r1 " Framed "ll .. Xd •,,,,, k , 2x6 @ 16 Irt O.C. 0.069 Exterior Finish: 3 Coat Stucco r. r t... x r .., '• -_ inside Finish: Gypsum Board • Cavity/Frame: R-15/2x4 R-15 Wall House/Garage Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 0.086 Other Side Finish: Gypsum Board • Inside Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 R-0 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. D.C. none 0277 Other Side Finish: Gypsum Board Around Roof Joists: R-17.0insul. • Cavity/ Frame: R-13.0/2x4Top ChM • Roof Deck Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 The Gap: present At is RoofCasita Attic Roots Wood Framed Ceiling in. O.C. R 30 0.040 Roofing: 10 PSF (Roofrile) Inside Finish: Gypsum Board - Cavity/Frame: R-15/2x4 R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 0,095 Exterior Finish: 3 Coat Stucco • Around Roof Joists: R-17.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd • Roof Deck Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tle Gap: present Attic RoofBedrooms Attic Roofs 1 Wood Framed Ceiling In. O.C. R30 0.040 Roofing: 10 PSF(RoofTile) Registration Number: 217-P010024838D-0DD-000-0000000-0000 Registration Date/Time: 2017-11.20 12:19:37 HERS Provider. CalCERTS Inc, CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-1814:38:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #1X(3271) Calculation DateMme: 14:37, Sat, Nov 18. 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr401.ribdl6x CFIR-PRF-01 Page 9 of 13 R-21 Wall House/Garage Interior Walls - - - Wood Framed Wall - - - 2x6 @ 16 in. O.C. R 21 0,064 Inside Finish: Gypsum B08rd • Cavity/Frame: R-2112x6 Other Side Finish:. Gypsum Board SLAB FLOORS _. 01_ 02 03 04 05 _... .. .. 06 07 -Name Zone Area (ftZ Perimeter(ft) Edge Insul. It -value S Depth Carpeted Fraction Heated _ Slab -on -Grade Living 1700 117 None 0.8 No Slab -on -Grade 2 Casita 304 70 None 0,8 No Slab -on -Grade 3 Bedrooms 1267 107 None 0.8 No Garage Slab Garage_ 634 65 None 0 No. BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Foam Insulation - Building Envelope Air Leakage - _ CFM50 Required Not Required - .. - Not Required Ma WATER HEATING SYSTEMS ;,.��:•. i- 01 02 ;E'` 03,,, k - 64 �.,-. DS 06 Name Syr_,tom7ypd ^tt�, _ C? Dtstrlbution.ljryei 5{Natos Neatera t R "Number of Heaters Solar Fraction (°C) DHW Sys 1 p g .. + �edrrct�alatiop�sh buttn with onand�r nt% .L 1�%D';Y". �Pa)er'�(:) f � 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element - Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor Energy Factor Efficiency Input Rating) Pilot I Thermal Efficiency lank Insulation R-value (IM/Ext) Standby Loss I Recovery Eff First Hour Rating I Flow Rate NEEA Heat Pump Brand / Model Tank Location or Amblent Condition DHW Heater 1 Gas Consumer Instantaneous - (UEF) 1 0 0.92 UEF 199,900 Btulhr 0 n/a 10 GPM n/a nla Registration Number: 217-P01D024838D-000-000-0000000-0000 Registration DateTme: 2017-11-20 12:19:37 CA Building Energy Efficiency Standards - 2016 Residential Compliance ReportVerslon - CF1R-090120117-934 SPt HERS Provider CaICERTS Inc. Report Generated at 2017-11.18 14:38:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #1X(3271) Calculation DateTme: 14:37, Sat, Nov 18, 2017 Page 10 of 13 Calculation Description: Tice 24 Analysis Input File Name: Lennr401.ribd16x SPACE CONDITIONING SYSTEMS 01 - 02. 03 04 05 06 SC Sys Name System Typo Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC - Livingl Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - Casita2 Heat Pump Heating and Cooling System Heal Pump System 2 Heat Pump System 2 HVAC Fan 2 Air Distribution System 2 HVAC - Bedrooms3 Other Heating and Cooling System Healing Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntriFurnace 1 92 AFUE Heating Component 3 CntrlFurnace 1 92 AFUE HVAC-HEATPUMPS 01 02 r ° 03 y` ..�,..,�..::.z .05;' :w1067 08 09 10 11 Name System t;1 Typoals,1 '" Numberoi. Unfis -" .Iieating Cooling Zonally Controlled Compressor Typo HERS Verification `HSPFICOP 'Cap47'` C' 7t SEER' hFA''" Heat Pump System 2 SplitHeatPump "` I1 t ' c 8.2 24A00 ° 1ti8D0 ) /4 11f Not Zonal Single Speed Heat Pump System 2-hers-cool HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 O7 08 - Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 Spli64irCond 1 12 14 Not Zonal Single Speed Cooling Component 1-herscool Cooling Component 3 SplitAirCond 1 12 14 Zonally Controlled Single Speed Cooling Component 3-hers-cool Registration Number. 217-P010024838D-000-000-000000041000 Registration Date<rme: 2017-11-20 12:19:37 HERS Provider: CaiCERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version-CFIR-09012017-934 SPi Report Generated at:2017-11-18 14:38:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #iX(3271) Calculation Date/Time: 14:37, Sat, Nov 18, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr4ot.dbdl6x CFi R-PRF-01 Page 11 of 13 HVAC COOLING . HERS VERIFICATION 01 02 - 03 04 .05 06 - Name Verified Airflow Airflow Target - Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Not Required Required Cooling Component 3-hers-cool Required 275 Required Not Required Required Heat Pump Syslorn 2-hers-cool Required 350 NotRequiird Not Requited J Required HVAC. DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value - Duct Location Bypass Dud HERS Verification " - Air Distribution System 1 DudsinAll Specked Lower Leakage Target 6 Conditioned zone None Air Distribution System 1-hers-0ist Air Distribution System 2 DuctslnAll Sealed and tested 6 Conditioned zone None Air Distribution System 2-hers-0ist Air Distribution System 3 DuctsInAll Specified Lower Leakage ''argot B Conditioned zone None Air Distribution System 3-hers-diet HVAC DISTRIBUTION • HERS VERIFICATION -s-: r 04 i- .ems;. '+`. 05:.06i 07 08 Name Duct Leaiwge verification _ JjDuct Leakage, Target(15) Vatrified:Duct; location- tflad VerDuct. Design rBuried Ducts Deeply Burled Ducts Low -leakage AlrHandler Air Distribution System 1-hers-0isl - Required 5.0 Required Not Required Not Required Not Required Required Air Distribution System 2-hers-0ist Required 5.0 Required Not Required - Not Required Not Required n/a Air Distribution System 3-hers-0ist Required 6.0 Required Not Required I Not Required Not Required Required HVAC-FAN SYSTEMS 01 02 03 04 Name - Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.56 HVAC Fen 1-hers-ten HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.56 HVAC Fan 3-hers-fan Registration Number 217-P010024838D-000-000-00000004)000 Registration DalefTme: 2017-11-20 12:19:37 HERS Provider: CaICERTS Inc - CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CFI R-09012017-934 SPt Report Generated at:2017.11-16 14:38:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #1X(3271) Calculation DateTme: 14:37, Sat, Nov 18, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr401.dbdi6x CF1R-PRF-01 Page 12 of 13 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required - 0.58 HVAC Fan 2-hers-fan Required - 0.58 HVAC Fan 3-hers-fan Required 0.58 IAQ (IndoorAlrQuality) FANS 01 02 03 04 os 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IA0VenIRp1 70 0.25. Default 0 Required 11 C E RT!31 I C, Registration Number 217-P01o024838D400.000.0000000-0000 Registration DateMme: 2017-11.2012:19:37 HERS Provider. CeICERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-09012017-934 SP1 Report Generated at: 2017-11-18 14:38:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #1X(3271) Calculation DaterTtme: 14:37, Sat, Nov 18, 2017 Page 13 of 13 Calculation Description: Title 24 Analysis Input File Name: Lennr401.ribdl6x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT - - 1. 1 certify that this Certificate of Compliance documentation is accurate and complete_ Documentation Author Name: Documentation Author Signalur, Rick Maurer Company: - -- Signature Date: -. Rick Maurer Title 24, Inc. 2017-11-20 12:18:54 � "� Address,. CEAMERS Certification Identification (If appticabi ' 7544 Saddlehill Trail R13-90-10024 city/Stale/Zip: Phone: Orange, CA 92869 714-771-1507 RESPONSIBLE PERSON'S DECLARATION STATEMENT 1 certify the following under penally of perjury, under the laws of the Slate of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24. Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to pid enforcarnefit.egancy tpi epproval,Wllh Sh1S bu8ding pertfibapplicaifon. Responsible Designer Name: P 9 Rc?spansibie DosignerSrgnaturo" .t e. s James JenikeA,<, k_ Company: fs E.t Date Signed: . r •.f r ! ; Lennar Homes - Southern CA 2017-11 201219:37 Address: - License: 980 Montecito Drive, Suite 302 City/StaterAp: Phone: Corona, CA 92879 951-817-3500 Digitally signed byCalC£RTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration L'♦1 • ICl7C Provider responsibility for the accuracy of the information. Easy to Verify at CaICERTS.com Registration Number: 217-P0100248386-000-000-0000000-0000 Registration DateMme: 2017-11-2012:19:37 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-18 14:38:26 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - Plan #1X(3271) Date 11/18/2017 System Name HVAC - Living Floor Area 1,700 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL Total Room Loads [±IO73 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK System Sensible Latent CFM Sensible -Heating Out ut erS stem 64,000 22,590 2,7601 501 19,648 Total Output Btu'h 64,000 0 Output Btuh/s 37.6 472 287 System 0 0 -Cooling Output per System 48,000 0 0 0 0 Total Output Btuh 48,000 0 472 23,534 2,760 0 Total Output Tons 4•0 287 Total Output Btuh/s ft 28.2 Total Output s ft/Ton 425.0 20,222 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Liv.HVAC Equipment Selection 8, Sizing by Others 30,808 9,825 64.000 Airflow cfm/s ft 1.18 Airflow cfm/Ton 500.0 64,000 Jan 1 AM Outside Air % 0.0% Total Adjusted System Output 30,808 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 9,825 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRIC# Airstream Temperatures at Time of Heating Peak 26 OF 68 IF 68 OF 105 OF --I Outside AirAr 0 cfm Supply Fan Heating Coil 2,000 cfm 68 OF ii 105 OF i ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF 75/62°F 75162°F 55/54°F Outside Air HTE _UAr 0 cfm Supply Fan Cooling Coil 55 / 54 OF 2,000 cfm ROOM 47.8% �T 75 / 62 °F 75162 OF 11-L-Eu i EnergyPro 7.2 by EnergySolf User Number., 1686 ID: Page 16 of 78 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Lennar Homes - Plan #1X(3271) 11/18/2017 System Name Floor Area HVAC - Casita 304 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 245 Return Vented Lighting Return Air Ducts Return Fan Ventilation r 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 24,000 5,192 493 229 6,562 Total Output Btuh 24,000 0 Output Btuh/s ft 78.9 109 87 Cooling System 0 0 Output per System . 24,000 0 0 0 0 Total Output Btuh 24,000 0 109 5,409 493 0 Total Output ons 2.0 87 Total Output Btuh/s ft 78.9 Total Output s ft/Ton 152.0 6,737 Airs stem - - CFM perSystem 1,000 HVAC EQUIPMENT SELECTION Airflow Jcfm 1,000 Casita HVAC Equipment Selection & Sizing by Othe 15,563 4,641 14,990 14,990 Airflow cfm/s ft 3.29 Airflow chnrron 500.0 Outside Air M 0•0% Total Adjusted System Output (Adjusted for Peak Design conditions) 15,563 4,641 0.00 Outside Air cfm/s ft TIME OF SYSTEM PEAK Jan 1 AM Note: values above given at ARl conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 68 OF 95 OF • C. . u-- Outside Air _._1_1_U 0 cfm Supply Fan Heating Coil 95 of 1,000 cfm ROOM 68 OF 68 IF (( COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 75 / 62 OF 75 / 62 OF 55154 OF Outside Air 0 cfm Supply Fan Cooling Coil 55 / 54 OF 1,000 cfm /. 46.7% � ROOM Jq 75/62OF 75/62OF EnergyPro 7.2 by EnergySoft User Number: 1666 ID: Page 17 of 18 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - Plan #1X(3271) Date 11/18/2017 System Name HVAC - Bedrooms Floor Area 1,267 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 772 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD. COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 48,000 16;244 . 2.0571 361 14,173 Total Output Stuh 48,000 0 Output Btuh/s ft 37.9 340 207 System 0 0 -Cooling Output per system 36,000 0 0 0. 0 Total Output Btuh 36,000 0 340 16,923 2,057 0 Total Output Tons 3.0 207 Total Out ut. Btuh/s ft 28.4 Total Output s ftrron 422.31 14,588 Air System CFM per System 1,400 HVAC EQUIPMENT SELECTION Airflow cfm 1,400 Bed.HVAC Equipment Selection & Sizing by Others 23,533 6,958 48,000 AIM ow ctm/s ft 1.10 Airflow cfmfron 466.7 Outside Air °% 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 23,533 6,958 48,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 68 OF 105 OF Outside Air 0 cfm Supply Fan Heating Coil 1,400 cfm 68 OF II 105 OF � ROOM 68 IF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 75/62IF 75/62OF 55/54OF 1-0 --.-- o --1• —�07 0 cfm Supply Fan Cooling Coil 1,400 cfm 75 162 of 55 / 64 IF 47 9% ROOM 75 162 OF EnergyPro 7.2 by EnergySoft User Number., 1686 ID: Page 18 of 18 BUILDING ENERGY ANALYSIS REPORT PROJECT: Lennar Homes - Plan #2(3314) Griffin Ranch 2017 La Quinta, CA Project Designer: Lennar Homes 980 Montecito Drive, #302 Corona, CA 92879 951-817-3600 Report Prepared by: Rick Maurer Rick Maurer Title 24 7544 Saddlehill Trail Orange, CA 92869 714-771-1507 Job Number: Date: 11/14/2017 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft_com. TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 HVAC System Heating and Cooling Loads Summary 14 9Y Y NY Job Number Ener Pro 7.2 b Ener Sot ID: User Number: 1686 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Griffin Ranch 2017 - Plan #2(3314) Calculation Daterrime: 13:58, Tue, Nov 14, 2017 Page 1 of 11 Calculation Description: Title 24 Analysis Input File Name: Lennr403.ribd16x GENERAL INFORMATION 01 Project Name - Griffin Ranch 2017 - Plan #2(3314) 02 Calculation Description Tiflo 24 Analysis 03 Project Location Griffin Ranch 2017 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code - 07 - - Compliance Manager Version BEMCmpMgr 2016.3.0 (934 SP1) 08 Climate Zone CZ15 09 Software Version EnurgyPm.7.2 10 Building Type Single Family 11 From Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units' -1 14 Total Cond. Floor Area (0) 3314 15 1 Number of Zones.- 1 16 Slab Area (fee 3314 17 Number of Stories 1 18 Addition Cond. Roar Area(ft2)1 n/a 19 Natural Gas Available yes 20 Addition Slab Area (ft2) 1 n/a 21 Glazing Percentage (k) 21;31, COMPLIANCE RESULTS 01 Building Compfieswith Computer Performance'u"°�-* 02 This building Incorporates features that *ulm field testing nr414,V (4aV0K9y a cart)* HERS ra$t.pn4or0re s perWin of a CEC-approved HERS provider. 03 This building Incorporates one or mare°.Special featuresshovm below"`" Registration Number. 217-P010024040E-000-000-0000000.0000 Registration DateMme: 2017-11-2012AB32 HERS Provider. CaICERTS Inc CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-09012017-934 SPi Report Generated at: 2017-11-14 13:58:44 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #2(3314) Calculation Datefrime: 13:58, Tue, Nov 14, 2017 Page 2 of 11 Calculation Description: Title 24 Analysis Input File Name: Lennr403.ribdl6x ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDWft2ryr) Design Design Margin Improvement Space Healing 1.39 1.41 -0.02 -1.4% Space Cooling 04.85 67.98 16.87 19.9 % IAQ Ventilation 0.9a 0.98 0.00 0.0% Water Heating 4.29 4.02 0.27 6.3% PV Credit - 0.00 0.00 - North Facing Compliance Total 91.61 74.39 17.12 10.7/s Space Healing - 1.39 1.76 -0,37 -26.6% Space Cooling 84.85 75.20 9.65 11.4% IAQ Ventilation 0.90 0.98 0.00 0.0% Water Healing 4.29 4.02 0.27 6.3% PV Credit - 0.00 0.00 - East Facing Compliance Total 91.61 81.96 9.66 10A % Space Heating - - 1.39 - 2.09 -0.70 -60.4% Space Cooling }� �, 8 66.26 E O.g9 C�c yyy 18.59 0.00 21.9% 0.0% IAQ Venttation WaterHeating 9 '^ �C"' 0 0.27 6.3% i i F R E' t �._ 0:00 1 �.) �_, 0.00 - PV Credit South Facing Compliance Total 91.61 -.> 73.36 1B.16 19.8% Space Heating 1.39 1.80 -0A1 -29.5% Space Cooling 84.85 73.95 10.90 12.8% IAQ Ventilation 0.98 0.98 0.00 0.0% Water Heating 4.29 4.02 0.27 6.3% PV Credit - 0.00 0.00 - West Facing Compliance Total 91.61 80.75 10.76 11.8% Registraton Number 217-P010024840E-1100-000.0000000-0000 Registration DateMme: 2017-11-20 12:48:32 HERS Provider. CoICERTs Inc. CA Building Energy Effidency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-1413:56:44 i0 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #2(3314) Calculation Dateffime: 13:58, Tue, Nov 14, 2017 Calculation Description: T ille 24 Analysis Input File Name: Lennr403.ribdl6x CFi R-PRF-01 Page 3 of 11 ENERGY DESIGN RATING - - Energy Design Rating (EDR) Is on alternate way to express the energy porterinance of a building using a -scoring system where 100.reprosonis the energy performance -of tho Residential Energy Services (RESNET) reference home charactedrdtion of the 20061nlematlonal Ertorgy Conservation Coda:11ECC) with California modeling assumptions. A score ofzero represents theenergy, performanye of -a building that combines high levels of energy etficloncywith renewable generation tWzero our its TDV energy. Because FOR Includes consideration of end consumer electronics), it Is:not used to show compliance wllh'Part 6 but may instead be used by local components not regulated by Title 24, Part 6 (such or,domestic appliances Jurisdictions pursuing local ordinances under Tille 24. Part 11(CALGroen� As a. Standard Design building under the 2016.Bu1141ng EnergyEHlctency Standards Is_slgnlpcantymore efficient than the baseline EOR.building, the EDR of the Standard Design building Is provided for Information. Similarly, the EDR score ottha'Proposed Beslgn ts.provldetl separatoty from the EDR value of Installed PV so that the effects of efficiency and renewable ener can both be wan EDR of Standard Efficiency . EDR of Proposed Efficiency EDR Value of Proposed PV .Battery Final Proposed EDR - North 64.6 - 47.0 - 0.0 47.0 East - 54.6 - 50.3 - - 0.0 - - 50.3 South 54.6 46.5 - ... 0.0 46.5 _ West 54.6 49.8 0.0 49.8 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and Qil verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family In climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) Including on -site photovoltaic (PV) renewable energy generation sufficient to acl1leve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. + Notes: If ,. gl % r - • Excess PV. Generation EDR Credit: Bypassing PV Eric 8mit pia-.�vlodnlcilt Ene m n INEM rules ._ - _ _ _, .. ., .. -: - - •- - f REQUIRED SPECIAL FEATURES `irP1 The following are features that must be installed as condition tar mae8ng lftc'nlodr3lad alp rgy performariw'':fw*this coriiputetan)ilys(s. • Non-standard roof reflectance • Insulation below roof deck -• Window, overhangs andfor fins • Nonstandard duct Iocatlon (any location other than attic) Recirculation with demand control, push button Registration Number 217-P010024840E-000-000.0000000-0000 Registration DateMme: 2017-11-20 12:48:32 HERS Provider. CeiCERTs inc, CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SPt Report Generated at 2017-11-14 13:58:44 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Griffin Ranch 2017 - Plan #2(3314) Calculation DateMme: 13:58, Tue, Nov 14, 2017 Page 4 of 11 Calculation Description: Tile 24 Analysis Input File Name: Lennr403.ribd16x HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis, Additional data[[ Is provided in the buHding components tables below. BuIl ding -level Verifications: • High quality Insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified ReMgerant Charge • Fan Efficacy WattsiCFM HVAC Distribution System Verifications: • Duct Sealing • Ducts located entirely In conditioned space confirmed by duct leakage testing • LowdaakageAir Handling Unit Domestic Hot Water System Verifications: —None •- BUILDING - FEATURES INFORMATION 01 02 OS 04 05 06 07 SNumberorbwalting' si'""" ir-" .w"` * Number of Ventilation Numberofwater Project Name Conditioned Floor Area (Of "Units ` Number o(BeQroortis . Number of 261111esA" .. Cooling Systems Heating Systems. Griffin Ranch 2017-Plarr#2(3314) 3314;„,,. ' ,tb,.'-A1 ,..,., Y.•_. �!� +•- t 0 1 - ZONE INFORMATION : 't. r 01 02 03 04 06 06 07 Zone Floor Area Avg. Calling Zone Name Zone Type HVAC System Name (ft2) . Height Water Heating System 1 Water Heating System 2 House Conditioned HVAC1 3314 12 DHW Sys 1 n1a Registration Number 2t7-P01Db24e40E-000.000.OD00000-0000 Registration DaleRme: 2017-11-2012:48:32 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SPt Report Generated at: 2017-11-1413:58:44 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Griffin Ranch 2017 - Plan #2(3314) Calculation Date/Time: 13:58, Tue, Nov 14, 2017 Page 5 of 11 Calculation Description: Title 24 Analysis Input File Name: Lennr403.ribdl6x OPAQUE SURFACES - 01 02 03 _ - 04 _ 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (R2) Window & Door Area (f12) Trh (deg) Front 2x6 Wall House R-21 Wall - 0 Front 660 338.597 90 Left 2x6 Wall House R-21 Wall 90 Left 700 70 90 Back 2x6 Wall - House R-21 Wan too Back 880 - 256.728 - 90 Right 2x6 Wall House R-21 Wall 270 Right. 530 64.3 90 Front Garage Wall House»_Garage_ R-15 Wall House/Garage n/a. .. n/a 220 21 We Right Garage Wall Houso»_Glirage R-15 Wall House/Garage - nla n/a 130 0 n/a Right 2x6 Garage Wall House»Ganiga;-- R-21 Wall House/Garage n/a n/a 40 0 n/a Ceiing Below Attic House R30Attic HPA n/a n/a 3314 n/a We FG Wall _Garago_ R-0 Wall 0 Front 220 128 90 LG Wall - _,Garage_ R-0 Wall 90 Left .: 190 0 90 RG Wall _Gatago_ R-0 Wail 270 Right 360 D BD Garage Ceiring _Garage_ ,;. R-0 Garage Attic - n/a n/a 654 n/a We ATTIC 01 02 i 03 - 07 08 Name - Construction 1 ' Tjipe r 1 ^1 RooRise�`" Roof Reflectance - Roof Emittance Radiant Barrier - Cool Roof Attic House Attic RoofHouse Unventilated 3 0.16 0.89 - No No Allic_Garagc_ Attic Garage Root Cons Ventilated 3 OAS 0.89 No No Registration Number. 217-P010024840E-000-000-0000000-0000 Registration Daternme: 2017-11-20 12:49:32 HERS Provider. Ce10ERT61nc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version-CF1R-09012017-934 SP1 Report Generated at: 2017-11-14 13:58:44 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #2(3314) Calculation DateMme: 13:58, Tue, Nov 14, 2017 Page 6 of 11 Calculation Description: Title 24 Analysis Input File Name: Lennr4O3.dbdl6x FENESTRATION/GLAZING 01 02 03 04 OS 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Mulliphor Area (ft") U-factor SHGC Exterior Shading Front Fixed Window Front 2x6 Wall (Front-0)_ 8.0 1.3 0.996 10.6 0.26 0.25 Insect Screen (default) Front Fixed 2 Window Front 2x6 Wall (Front-0) 4.0 6.0 1 24.0 0.26 0.25 Insect Screen (default) Front Folding Window Window Front 2x6 Wall (Front-0) 8.0 5.0 1 40.0 0.32 0.20 Insect Screen.(default) Front Stacking Glass Door Window Front 2x6 Wall (Front-0) 24.0 10.0 1 240.0 0.32 0.20 Insect Screen.(detau0) Left Openable Window Left 2x6 Wall (Left-90) t 31.0 0.30 0.23 Insect Screen (default) Left Openable 2 Window Left 2x6 Wall (Leftr90) 2.5 6.0 1 15.0 0.30 023 Insect Screen (default) Left Hinged Glass Doer Window Left 2x6 Wall (Lett-90) - - 1 24.0 0.30 0,23 Insect Screen (dofaull) Back Openable Window Back 2x6 Wall (Back-180) 21.0 6.0 1 126.0 0.30 0.23 Insect Screem(defaufi) Back Fixed Window Back 2x6 Wall (Back-180) - 1 36.0 0.26 0.25 Insect Screen (default) Back Fixed 2 Window Back 2x6 Wall (Back-180) _ 12.0 1.3 1.003 16.0 0.26 0.25 Insect Screen (default) Back Hinged Glass Door Window Back 2x6 Wall (Back-180) 5.3 8.0 1 42.7 0.30 0.23 Insect Screen (default) Back Openable 2 Window tia0k'2i6 Wa(I (Badc;180)j �j�u I - jr. '1_ 36.0 0.30 0.23 Insect Screen (default) Right Openable Window tt Nipht 2x6,";tRlgt (170) '"''` 1 '41i 2,5? 'rr'{Ii.O ft '1!j. { 15.0 0.30 0.23 Insect Screen (default) Right Fixed WindowRlgh!`2zS'"Ill (Rfghi270)' "`^' ' �" ` 0W = 41 to_-13:3 0.26 0.25 Insect Screen (default) Right Openable 2 Window `�eA, Rlghr2i 5 V!�4 (R)96t-270) ( { = .J /--# + 1a'^ ,(36.0 0.30 0.23 Insect Screen (default) OPAQUE DOORS 01, 02 03 04 Name Side of Building Area (ftz) U.factor Front Door Front 2x6 Wall 24.0 0.50 Front Garage Door Front Garage Wall 21.0 0.50 Car Door FG Wall 128.0 0.50 Registration Number. 217-POlOC24840E-000.000-0000000-0000 Registration Date/Tlme: 2017-11-20 12:48:32 HERS Provider: Ca10ERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SPt Report Generated at: 2017-11-1413:58:44 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #2(3314) Calculation Date/Time: 13:58, Tue, Nov 14, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr403.ribdl6x CFI R-PRF-01 Page 7 of 11 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang :.... Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up .Depth Top Up Dist R Bot Up Front Fixed 12 0.5 2 2 0 0 0 0 0 0 0 0 0 Front Fixed 2 12 1 2- 2 0 0 0 0- 0 0 0 0 0 Front Folding. Window 12 2.5 2 2 0 0 0 0 0 .0 0 0 0 Front Stacking Glass Door 12 1 2 2 0 0 0 0 0 0 0 0 0 Left Openable 2_ E 1 2 2 0 0 0 0 0 0 0 0 0 Back.Openable 1.5 2 2. 2 0 0 0 0 0 0 0 0 0 Back Fixed 2 - 1.5 2 2 2 0 0- 0 - 0 0 0 0 0 0 Back Hinged Glass Door 4 1 2 2 0 0 -0 - - 0 0 0 0 0 0 Right Openable 6 1 2 2 0 - 0 0 0 0 0 0 o 0 Registration Number: 217-P010024840E-000-000-0OD0000-0000 Registration Date/fine: 2017-11-2012:48:32 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-14 13:58:44 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #2(3314) Calculation Daterrime: 13:58, Tue, Nov 14, 2017 Page 6 of 11 Calculation Description: Title 24 Analysis Input File Name: Lennr403.dbdl6x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 OS 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers Ceilings (below Inside Finish: Gypsum Board R-0 Garage Attic attic) Wood Framed Ceiling _ 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: no insul. /2x4 - Inside Finish: Gypsum Board • Cavity/Frame: noinsuf./2x4 R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. D.C. none 0,361 Exterior finish: 3 Coal Stucco - Cavity/Frame: no insul. /2x4 Top Chrd • Roof Deck: Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap., present Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.400 •• Roofing: 10PSF (RooTle) _ Around Roof Joists: R-17.0 insul. • Cavity/Frame: R-13,0/2x4 Top Chrd • Roof Deck: Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic RoefHouse I Attic Roofs Wood Framed Ceiling in, O.C. R 30 0.040 Roofing., 10 PSF (RoofTile) Ceilings (below - x O C ` - I Inside Finish: Gypsum Board Cavity/Frame: no Insul. /2x4 Cavity R-30 Attic HPA attic) Wood Frar(,tc'dsCehing, 4;2x4 @ 24 In. _ none _ 0.481 Inside Finish: Gypsum Board Cavity/frame: R-21/2x6 ri. P Exterior Finish: 3 Coal Stucco R-21 Wall Exterior Walls +r�^lpod Framed Wa1 -:.; , 2x6 @ 16 in, O.C. R 21 , 0.069 .. w a •. + r • .f > • • - Inside Finish: Gypsum Board • Cavity/Frame: R-15/2x4 R-15 Wall House/Garage Intedor Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 0.086 Other Side Finish: Gypsum Board - - Inside Finish: Gypsum Board • cavity/Frame: R-21 /2x6 R-21 Wall House/Garage Interior Walls Wood Framed Wall 2x6. @ 16 in. O.C. R 21 0,064 Other Side Finish: Gypsum Hoard .SLAB FLOORS 01 02 03 04 05 us 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slabon-Grade House 3314 225 - None 0.8 No Garage Slab - Garage_ 654 77 None 0 No BUILDING ENVELOPE -- HERS VERIFICATION of 02 .. 03 04 Quality Insulation Installation (011) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM60 Required Not Required Not Required - nia Registration Number: 217-P010024E40E-00D-000-OOo0000A000 Registration Dalerrime: 2017-11-20 12:48:32 HERS Provider. CaICERTs Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-1413:58:44 0 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #2(3314) Calculation Date/Time: 13:58, Tue, Nov 14, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr403.ribdl6x CF1R-PRF-01 Page 9 of 11 WATER. HEATING SYSTEMS 01 02 03 04 05 06 Name System Type _ Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 7 DHW Recirculation with demand control, push button DHW Heater 1 (1) 1 ,0% WATER HEATERS 01 02 03 04 1 05 06 07 08 09 10 11 .12 Name Heater Element Type Tank Type _ Number of Units Tank Volume (gal) Uniform Energy Factor I Energy Factor / Efficiency Input Rating Pilot / Thermal Efficiency / Tank Insulation R-Value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating I Flow Rate NEEA Heat Pump Brand / Model Tank Location or Ambient Condition DHW Heater 1 Gas Consumer Instantaneous (UEF) 1 0 0.92 UEF 199,900 Btu/hr 0 n/a 10 GPM - rda n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 - 05 06 SC Sys Name .,. System..Typ& _ _. - . �FNeating`Unt(°Nnigo'"}y" ',(�'Cooling Unit Name _ Fan Name Distribution Name HVACt Othe? Heatin mend CooUrig �,..�". system, +� eatklgCgmpon t1 � a fir" j }e abl CorpF I 1 �rr.N ;1 y, Ana HVAC Fan 1 Aa Air Distribution System 1 HVAC-HEATING UNIT TYPES ... 01 02 0J - 04. .. Name System Type Number of Units Efficiency Heating Component 1 CntdFumace - 2 92 AFUE HVAC -COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled .Compressor Type HERS Verification Cooling Component 1 SplifAirCond 2 12 14 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER _. Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required �350 Required - - Not Required J.Required Registration Number: 217_P010024840E-000-000-0000000-Oe00 Registration DateRme: 2017-11-20 12:48:32 HERS Provider: CaICERTS Inc - CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version-CFIR-09012017-934 SPI Report Generated at: 2017-11-14 13:58:44 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Griffin Ranch 2017 - Plan #2(3314) Calculation DateTme: 13:58, Tue, Nov 14, 2017 Page 10 of 11 Calculation Description: Title 24 Analysis Input File Name: Lennr403.ribdl6x HVAC - DISTRIBUTION SYSTEMS _ 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location _ Bypass Duct HERS Verification Air Distribution System 1 DuctslMll Specified Lower Leakage Target 6 Conditioned zone None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 - 04 05 06 07 06 Name Duct Leakage Verification Duct Leakage Target(%) Verified Duct Location Verified Duct Design Burled Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hersdlst Required 5.0 Required Not Required Not Required Not Required Required HVAC-FAN SYSTEMS 01 02 03 04 Name - - Type - Fan Power (Wafts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 03 Name `L3- am-`r" '' � "Vor nid Fan Watt Oraw *'- "` �+a Required Fan Efficiency (WattsrCFM) HVAC Fan 1-hers-fang%, Required j \i' ° - q ! Z. -:� t :. S 0.58 IAQ (Indoor Air Quality) FANS 01 02 - - 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(h) 1 HERS Verification SFam IAOVentRpt 71 0,25 Default 0 Required Registration Number: 217-P010024840E-000-000-0000000-0000 Registration DaleMme: 2D17-11-2012:48:32 HERS Provider CeICERTs Inc, CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-09012017-934 SP1 Report Generated at 2017-11-14 13:5B:44 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #2(3314) Calculation Date/Time: 13:58, Tue, Nov 14, 2017 Page 11 of 11 Calculation Description: Title 24 Analysis Input File Name: Lennr403.ribd16x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT - 1, 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signalurr, Rick Maurer Company: Signature Dale: Rick Maurer Title 24, Inc. 2017-11-2012:48:04 RR (^ REv tt� 'k.gbnd6,Y fnnrCa+�Nh Address: - CEA/HERS Certification Identification (If applicabl 7544 Saddlehill Trail R13-90-10024 Citylstatelzip: Phone: Orange, CA 92869 714-771-1507 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the Slate of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design Identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications Identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted ta.,�he enforc9ment agaRry_for app[gvg1 yfill><this building permit application, .. . Responsible Designer Name: Tr - Respon le Designer Signatuio^4,1. T x Gf > ri k u James Jenike _J r. o��F�Cea�u Company: i'l t , E ' Datai Signed Lennar Homes - Southern CA 2017-1 f-201248:32 Address: License: 980 Montecito Drive, Suite 302 City/State/Zip: - Phone: Corona, CA 92879 951-817-3500 M_ r M Digitally signed by Ca10ER7S. This digital signature is provided in order to secure the content of this registered document and in nowayimpiies Registration Provider responsibility for the accuracy of the information, Easy to Verify at CaICERTS.com Registration Number 217-P010024840E-000-000-000000D-0000 Registration DateRme: 2017-11-20 12:48:32 HERS Provider. CaICERTS be. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-1413:58:44 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - Plan #2(3314) Date 11/14/2017 System Name HVAC Floor Area 3,314 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 3,002 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 64,000 42,284 4,459 892 35,027 Total out ut. Btuh 128,000 0 Output Btuh/s ft 38.6 655 432 Cooling System 0 0 Output perSystem 48,000 0 0 0 0 Total Output Btuh 96,000 0 655 1 43,5931 4,459 0 Total Output Tons 8.0 432 Total Output BtulVs ft 29.0 Total Output s `f rrbn) 414.3 35,890 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 4,000 HVAC Equipment Selection & Sizing by Others 61,709 19,00 128,000 Airflow cfmis ft l 1.21 Airflow cfm/Ton) 500.0 Outside Air (%) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK I 61;709 19,410 128,000 Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 68 OF 105 OF 0-0- Outside Air I 0=1-- 0 cfm Supply Fan Heating Coil 4,000 cfm 68 OF ( 105 OF ' ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF 75/62°F 75/62°F 55/54°F Outside AirAr - I> 0 cfm Supply Fan Cooling Coil 55154 OF 4,000 cfm 47.5% ROOM In 75 / 62 °F 75/62 OF LEF-Efl EnergyPro 7.2 by EnergySoft User Number., 1686 ID: Page 14 of 14 BUILDING ENERGY ANALYSIS REPORT PROJECT: Lennar Homes - Plan #3(3475) Griffin Ranch 2017 La Quinta, CA Project Designer: Lennar Homes 980 Montecito Drive, #302 Corona, CA 92879 951-817-3600 Report Prepared by: Rick Maurer Rick Maurer Title 24 7544 Saddlehill Trail Orange, CA 92869 714-771-1507 Job Number: Date: 11 /20/2017 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and Is authorized by the Callfomia Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by Energy Soft Software—www.energysoft.com. TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 HVAC System Heating and Cooling Loads Summary 16 EnergyPm 7.2 by EnergySoft Job Number ID: User Number. 1686 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #3(3475) Calculation Daterrime: 08:41, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr404.ribdl6x CF1R-PRF-01 Page 1 of 13 GENERAL INFORMATION 01 Project Name Grif0n Ranch 2017 - Plan N3(3475) 02 Calculation Description Title 24 Analysis 03 Project Location Grii0n Ranch 2017 04 City La Quints, 05 Standards:Verslon Compliance 2017 06 Zip Code 07 - - Compliance Manager Version BEMempMgr 2016.3.0 (934 SP1) pg Climate Zone CZ15 09 - Software Version EnergyPro Z2 10 Building Type Single Family 11 Front Orientation (degfCardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 , 14 Total Cond. Floor Area (ft2) 3475 15 Number of Zones 2 16 Slab Area (0) 3475 17 Number of Stones 1 16 Addition Cond. FloorA. reate) Np 19 Natural Gas Available Yes 20 z Addition Slab Area (ft) nra 21 Glazing Percentage (%). - - ,219% - - COMPLIANCE RESULTS -01 Building Complies with ComputerPerformance '-.,,�„'...,,,„..I° -�•--- 02 This building Incorporates features thabfoyuil'e fiojdtesltnp amdloi�vetificahor % a:ceil'died HERS raldtunder the superr, pn of a CEC-approvetl HERS provider. _. .. 03 This building incorporates one or mere SpOdal FeatUf fs7sliovll g01ow.'{ Registration Number. 217•P010024a47D-000-OOO-0ODO000-0ODO Registration DateTme: 2017-11-2012:19:39 HERS Provider CatCERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SPt Report Generated at: 2017-11-20 08:42:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Gruen Ranch 2017 - Plan #3(3475) Calculation DateTme: 08:41, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr404.ribdl6x CFI R-PRF-01 Page 2 of 13 ENERGY USE SUMMARY Use Energy Use Energy Standard Proposed Compliance Percent Design Design MarginJkTD Improvement • Space Heating 2.16 2.06 0.10 4.6% Space Cooling 89.19 76.91 12.23 13.8% IAQ Ventrmllon 0.96 0.96 0.00 0.01/6 Water Heating 4,10 3.83 0.27 6.6% PV Cre III - 0.00 0.00 - North Facing Compliance Total 96.41 83.76 12.65 13.1 % Space Heating 2,16 2.53 -0.37 -17.1 % Space Cooling 89.19 80.69 8.60 9.6% IAQ Ventilation 0,96 0.96 0.00 0.0% Water Heating 4.10 3.83 0.27 6.6% PV Credit - 0.00 0.00 - East Facing Compliance Total 96.41 87.91 8.50 8.8% Space Heating Space Cooling 2.16 2.98 813�i19Ke"E RTSii ti ii' 2BH0.00 -0.80 1400 -37.01A 1 % 0.0% IAQ VenUVatian088 on WaterHeafing C 0 "''•� }� 0.27 ,0 8.6% 4 �-� , I k" F) R 0 o46 1 D F, R 0.00 - PV Credit South Facing Compliance Total 96A1 82.74 13.67 14.2% Space Heating 2.16 2.34 -0.18 A.3 % Space Cooling 89.19 74.64 14.35 16.1% IAQ Ventilation 0.96 0.96 0.00 0.0% Water Heating 4.10 3.83 0.27 6.6% PV Credit - 0.00 0.00 - West Facing Compliance Total 96.41 81.97 14.44 15.0% Registration Number. 217-P010024647D-000-000-0000000-0000 Registration DateMme: 2017-11-20 12:19:39 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP7 Report Generated at 2017-11-20 08:42:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #3(3475) Calculation Datefiime: 08:41, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis input File Name: Lennr404,ribdl6x CF1 R-PRF-01 Page 3 of 13 ENERGY DESIGN RATING Energy Design Rating (EDR) Is:an alternate way to express ihe'enorgy performance oba building using a scor(ng system where 100'ropreaaMs,lho energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 international Enorgy"Conservatfon CodeKtC) with California rnodoling assumptions. Ascore of zero represents high levels of with renewable generation to"zero out" Its TDV energy. Because EDR includes consideration of the energy porformance of a building that.combines _energy'eificioncy components not -regulated byTiUa 24. Part GAsuch as domestic appliances and,consumer c_ lo_ciro_ nits), ills not used to allow compliance with Part 6but may instead be used by local jurisdictions pursuing focal ordinances under Title 24, Part 11(CALGreen). As aStandard Design building under the 2010 Building Energy Efficiency Standards Is significantly more efficient than the bn*eflne EDR building, the EDR of the Standard Design building is provided far Information. Slmilarly, Ihe.EDR score of the'Proposed Design Is!provided separately from theEDR value of Installed PV sothal the effects of efficiency aiuf rendwable energy can bottrbeseen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV ♦ Battery Final Proposed EDR North 63.9 48.5 - 0.0 48.5 East 53.9- 50.2 0.0 60.2 - South 53.9 48.0 0.0 .. 48.0 - West 63.9 47.7 - 0.0 47.7 Q Design meets Tier 1 requirement of 1S% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. Q Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family In climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) Including on -site photovo@alc (PV) renewable energy generation sufficient to achleve a .. Final Energy Design Rating (FOR) of zero or less. The PV System must be verified. ,_ - Notes: IT.. "" ( fyt g(NEEM1 • Excess PV Generation EDR Credit: Bypassing PV size Ilmil.ma vtolato N E1 Me rin rules : Ft .REQUIRED SPECIAL FEATURES The following are features that must be installed as condition tar meeling IhQ modeleb energyperfdrrrialico' for`Ihis computer anaty`sis_ {" • Non-standard root reflectance • Window overhangs and/or fins • Non-standard duct location (any location other than attic) • Recirculation with demand control, pushbutton i Registration Number: 217-P010024847D-000.000.0000000.0000 Registration Date/Time: 201741-20 12:19:39 HERS Provider. CeICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SPt Report Generated at: 2017-11-20 08:42:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #3(3475) Calculation Daterrime: 08:41, Mon, Nov 20. 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr4D4.fibdl6X CFI R-PRF-01 Page 4 of 13 HERS FEATURE SUMMARY The following is a summery of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail Is provided in the building components tables below. Building -level Verifications: • High quality Insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Ducts located entirely in conditioned space confirmed by dud leakage testing • LowdoakageAir Handling Unit Domestic Hot Water System Verifications: — None — BUILDING • FEATURES INFORMATION at 02 03 04 05 06 - 07 Numbor of Dwe)Iing�''n'-`s'''' yl " } Number of Ventilation Number of Water Project Name Conditioned FloorAiaa(ft'i '"'Unity ;Numbof of Bedroorrl;,- Numbergt Zones?* Cooling Systems Heating Systems Griffin Ranch 2017 - Plan 113(305) 3475p,,, ..:,. w+i+ p<, ., A 4,, a+- T, # 2> •� �`.� 0 1 - ZONEINFORMATION"'t � : }"•i- 01 02 03 04 as 06 07 Zone Floor Area Avg, Calling Zone Name Zone Type. HVAC System Name (fil Height Water Heating System 1 Water Heating System 2 -QvinglGuost Conditioned HVAC - Living/Guestl 1955 12 DHW Sys 1 n/a Bedrooms Conditioned HVAC - Bedrooms2 1520 12 DHW Sys 1 n/a Registration Number 217-P010024947D-000-000-0000000-0000 Registration Date rime: 2017-11.2012:10:39 HERS Provider: CaICERTS Inc,. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 08:42:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Gruen Ranch 2017 - Plan #3(3475) Calculation DateTme: 08:41, Mon, Nov 20, 2017 Calculation Description: Tifte 24 Analysis Input File Name: Lennr404.dbdl6x CF1R-PRF-01 Page 6 of 13 OPAQUE SURFACES 01 o2 03 04 as 06 07 0a Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (n) Taft (deg) Front 2x6 Wall Living/Guest R-21 Walt 0 Front 516 113.5 90 Left 2x6 Wall Uving/Guest - - - R-21 Wall 90 Left 169 0 90 Back 2x6 Wall Uving/Guest R-21 Wall 180 Back 504 - 307.5 - 90, Right 2x6 Wall Living/Guest R-21 Wall 270 Right 196 112.5 90 Front Garage Wall Uving/Guest»_Garage_ R-15 Wall House/Garage Na n/a - 99 - - 0 n1a Left 2x6 Garage Wall LI rfnsfGuast»_Garage_, R-21 Wall House/Garage n/a nla 111 21 n/a Right 2x6 Garage Wall Llving/Guest» _ Garage_ R-21 Wall House/Garage Na We 170 21 nla Interior Surface Uving/Guest»Bedrooms R-0 Walll Na n/a 600 0 No Ceiling Below Attic Living/Guest R-30 Attic HPA Na n/a 195.5 n/a n/a Lett 2x6 Wall 2 Bedrooms R-21 Wall 90 Left 864 100.5 90 Back 2x6 Wall 2 Bedrooms R-21 Wall 100 Back 390 135 90 Right 2x6 Wall Bedrooms R-21. Wall - 270 Right 864 53.5 90 Front Garage Wall 2 Bedrooms»" 4gl 76 0 n/a0 Ceiling Below Aitic 2 .. Bedrooms . , ._ ._ f %-30 At9c HPAJ � r4, . f ria;1 [G, _ 1520 Na We FG Wall _Garag@_ ,: ... .,,. .R-0 Wa)t-,:... .-. -... . 0.. P. _.. RVRI _ ... - 320 .. .196 : .: .. _ 90 LG Wall _[3eraga r ° � ' ' -R=0 W811t , I ' ` -W t10 t '•'"r Left 1 220 - 0 90 RG Wall _Goraga_ R-0 Wall 270 -Right 280 0 90 Garage Ceiling Gatagc_ - R-0 Garage Attic We n/a 645 Na n/a ATTIC . 07 02 03 04 Os 06 o7 Ott Name Construction type Roof Rise Roof Reflectance Roof Emlttance Radiant Barrier Cool Roof _ Attic Living/Guest Attic RoofLiAng/Guest Unventilated 3 0.16 0.89 No No Attic Bedrooms Attic RoofBedrooms Unventilated - 3 0.16 0.89 No No Attic_Garage_ Attic Garage Roof Cons Ventilated 3 0.16 0.89 No No Registration Number: 217-1`010024047D-000-000-MODOD-OM Registration DateMme: 20W-11-20 12:19:39 HERS Provider. CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11.20 08:42:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #3(3475) Calculation DateTme: 08:41, Mon, Nov 20, 2017 Page 6 of 13 Calculation Description: Title 24 Analysis Input File Name: Lennr404.ribdl6x FENESTRATION I GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Ilduitipli it Area (ft2) U-factor SHGC Exterior Shading Front Openable Window Front 2x6 Wail (Front-0) 2.0 4.0 1 8.0 0.30 0.23 Insect Screen (default) Front Fixed Window Front 2x6 Wail (Front-0) 2.5 7.0 1 17.5 0.26 0.25 Insect Screen (default) Front Openable 2 Window Front 2x6 Wall (Front-0) 3.0 6.0 1 10.0 0.30 0.23 Insect Screen (default) Front Openable 3 Window - Front 2x6 Wall (Front-0). 3.0 6.0 1 18.0 0.30 0.23 Insert Screen (default) Front Hinged Glass Door Window Front 2x6 Wall (Front-0) 3.0 8.0 1 - 24.0 0.30 0.23 Insect Screen (default) Back Stacking Glass Door - Window Back 2x6 Wall (Back-180) 24.0 10.0 1 240.0 0.32 0,20 Insect Screen (default) Back Fixed Window Back 2x6 Wail (Back-180) 9.0 1.5 1 13.6 0.26 0.25 Insect Screen (default) Back Openable Window Back 2x6 Wall (Back-180) 9.0 6.0 1 54.0 0.30 0.23 Insect Screen (default) Right Sliding Glass Door Wndow Right 2x6 Wall (Right-270) 12.0 8.0 1 96.0 0.28 0.22 Insect Screen (default) Right Fixed Y6913d" Right 2x6 Wall'(Right-270) 11.0 1.5 1 16,5 0.26 0.26 Insect Screen (default) Left Hinged Glass Door Window Left 2x6 Well 2 (left-90) 3.0 8.0 1 24.0 0.30 - 0.23 Insect Screen (default) -- - - left Fixed- Window lcfl`21i6_Wall 2(LeR•90)" "Ay_a ` "' 3(l)�x",9.5 1 ..4.5 0.26 0.25 Insect Screen (default) Left Openable Window `k L: tt 2x6 Y*ig2 ((4-90) iV, j wt4 6.0%. - 6.0 4x 'K1 36.0 0.30 0.23 Insect Screen (default) Left Openable 2 Window`t N. LeR 7X-S' it12 (Loft=90)`= "` �6.0 ' '' 1'6.0 # Ai 30°0 0.30 0.23 Insect Screen (default) Back Fixed 2 Window -"� Baaw'z 6 "11218ock=16u) )•' (••;6.0'� j t . 1.5( ,,i 1 -_ } 9.0 0.26 0.26 Insect Screen (defauli) Back Fixed 3 Window _ Back 2x6 Well 2 (Back-180) 6.0 1.5 1 9.0 0.26 0.25 Insect Screen (default) Back Fixed 4 Window Back 2x6 Wall 2 (Back-180) 6.0 6.0 1 36.0 026 0.25 Insect Screen (default) Bade Openable 2 Window Back 2x6 Wall (Back-100) 6.0 6.0 1 36.0 0.30 0.23 Insect Screen (default) Back Fixed 5 Window Back 2x6 Wall 2 (Back-180)- 6.0 1.5 1 9.0 0.28 0,25 Insect Screen (default) Back Operable 3 Window Back 2x6 Wall 2.(Back-180) 6.0 6.0 1 36.0 0.30 0.23 Insect Screen (default) Right Openable Window Right 2x6 Wall 2 (Right-270) 5.0 6.0 1 30,0 D.30 0.23 Insect Screen (default) Right Fixed 2 Window Right 2x8 Wail 2 (Right-270) 5.0 1.5 1 7.5 0.26 025 Insect Screen idefaull) Right Openable 2 Window Right 2x6 Wall 2 (Right-270). 4.0 4.0 1 16.0 - 0.30 0.23 Insect Screen (default) Registration Number; 217-P010024847D-000-000-0000000-0000 Registration DafeRme: 2017-11-20 12:19:39 HERS Provider. CaICERTS ink. CA Building Energy Efficiency Standards .2016 Residential Compliance Report Version - CFt R-09012017-934 SP1 Report Generated at- 2017-11.20 08:42:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #3(3475) Calculation DateTme: 08:41, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr404.ribdl6x CF1 R-PRF-01 Page 7 of 13 OPAQUE DOORS -- - - 01 .. .. 02 03 04 Side of Building Area (ft2) U-(actor Name Front Door Front 2x6 Wail 28.0 0,60 - Left Garage Door - - Left 2x6 Garage Wall 21.0 0.50 Right Garage Door " . Right 2x6 Garage Wall - 21.0 0.50 - Car Door FG Wall 196.0 0.50 ..CaICEK r , Registration Number 217-P0100249470.e0e.ee0.00o01 OO-MOD Registration DateRme: 2017-11-2012:19:39 HERS Provider. GaICERTs Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 08:42:25 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Gruen Rancn 2017 - Plan #3(3475) Calculation DateMme: 08:41, Mon, Nov 20, 2017 Page 8 of 13 Calculation Description: Title 24 Analysis Input File Name: Lennr404.ribdl6x OVERHANGS AND FINS 01 02 1 03 1 04 1 06 O6 07 OB 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right... Extent Flap Ht. Depth Top Up Dist L sot Up Depth Top Up Dist R 9ot Up Front Openable 5 1 2 2 0 0 0 0 0 0 0 0 0 Front Fixed - 10 1 2 ' 2 - 0 0 0 0 0 0 0 0 0 Front O&Mbte 2 3 1 2 2 O 0 0 0 0 0 0 - 0 - 0 Front Openable 3` 3 1 2 2 0 0 0 0 0 0 0 0 0 Front Hinged Glass Docr 3 1 2 2 0 0 0 0 0 0 0 0 0 Bark Stacking Glass Door 24 1 2 2 0 - 0 0 0 0 0 D 0 0 Beck Fixed 1.5 2 2 2 0 0 0 0 0 0 0 0 0 Back Operable 1.5 4 2 2 0 0 0 0 0 0 0 0 0 Right Sliding Glass Dow 10 3 2 2 0 0 0 0 0 0 0 0 0 Right Fixed 10 1 2 2 0 0 1 0 0 0 0 0 0 0 Left Hinged Glass Door 6 3 +':2 - g 2 I— `0 09 0 0 0 0 0 0 Left Fixed 6 1 11 2,,,.4 I± "0� a{ 0'';k Of t ;0� 0 0 0 0 0 Left Openable 1.5 V FJ 4 .xa2t�.A ir -2--AO ACOMO Y /i 0 ftw! ` Ott 2 i; 0AW 0 0 0 _ _ 0 0 -. Left OpenaBte 2 1.5 'N4 - i--i2 (-" �y 2 t.., .D �s f� �0 t.l' 0,' F O R 0 0 0 0 0 Back Fixed 2- 1.5 2 2 2 0 0 0 0 0 0 0 0 0 Back Foxed 3 1.5 2 2 2 0 0 0 0 0 0 0 0 0 Back Fixed 4 1.5 4 2 2 1 0 0 1 0 0 0 0 0 0 0 Back Opona61e2 1.5 4 2 2 0 0 0 0 0 0 1 0 0 D Back Fixed 5 _ 1.5 2 2 2 0 0 0 0 0 0 0 0 0 Back Openable 3 1.5 4 2 2 0 0 0 0 0 0 0 0 0 Right Openable 1.5 2 2 2 0 0 0 O 0 0 0 D 0 Right Fixed 2 1.5 4 1 2 2 0 0 0 0 0 0 0 0 0 Right Openable 2 1.5 4 1 2 2 0 0 0 0 0 0 0 0 0 Registration Number 217-PD10024847D-000-000-0000000-0000 Registration DateMme: 2017-11-20 12de:39 HERS Provider. CWCERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-09012017-934 SP1 Report Generated at: 2017-11-20 08:42:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R•PRF-01 Project Name: Griffin Ranch 2017 - Plan 113(3475) Calculation DateMme: 08:41, Mon, Nov 20, 2017 Page 9 of 13 Calculation Description: Title 24 Analysis Input File Name: Lennr404.ribdl6X OPAQUE SURFACE CONSTRUCTIONS 01 02 03 - - 04 05 06 07 Total Cavity winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers Ceilings (below Inside Finish: Gypsum Board R-0 Garage Attic attic) Wood Framed Ceiling 2K4 @ 24 In. O.C. none 0.481 Cavity/Frame: no insul. /2x4 inside Finish: Gypsum Board • Cavity/Frame: no Insul. /2x4 R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C, none 0.361 Exterior Finish: 3 Coat Stucco -- .. Cavity/Frame: no insul. /2x4 Top Chn1 • Roof Deck. Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O,C. none 0.400 Roofing: 10 PSF (RoofTile) - - Around Roof Joists: R-17.0 insul. • Cavity/Frame.,R-13.0/2x4Top Chrd • Roof Deck: Wood Siding/shealhing1decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap., present Attic RoofUving/Guest Attic Roofs Wood Framed Ceiling in. O.C- R 30 0.040 Roofing: 10 PSF (Rooffile) Ceilings (below rr- Inside Finish: Gypsum Board R-30 Attic HPA attic) WoodFrutped CciOng.. �" 2ir4 QA 2-41n. O,G.w 7— none,. _ -0.485 •Cavity /Frame: no lose!/2x4 #', t �, r#, 2: I t��# A "�'x� Ca Inside Finish: Gypsum Board P •Cavity/Frame: R-2f/2x6 R-21 Wall { Exterior Walls y, `(� yrwdFrametl 21-. - r.0.069 ExfedorFinish: 3 Coat Stucco '•� o c $.. • • _.r - * `• '+ ' •-' Inside Finish: Gypsum Board • Cavity/frame: R-15/2x4 R-15 Wall House/Garage Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 0.086 Other Side Finish: Gypsum Board - - Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 R-21 Wall House/Garage Interior Walls Wood Framed Wall 2x6 @ 16 In. O.C. R 21 0.064 Other Side Finish: Gypsum Board • Inside Finish: Gypsum Board Cavity/Frame: no Insui. /2x4 R-0 Weill Interior Walls Wood Framed Wall _2x4 @ 16 in. O.C. none 0.277 Other Side Finish: Gypsum Board • Around Roof Jofsts: R-17.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd • Roof Deck: Wood Siding/sheathing/decking 20 Top Chord of Roof Truss @ 24 Tile Gap: present Attic RoofBedrDOMS I Attic Roofs Wood Framed Ceiling in. D.C. R 30 0.040 Roofing: 10 PSF (ROPM70 Registration Number: 217-P010024847D-000-000-Moo0o0-0008 Registration DateRme: 2017-11-20 12:19:39 HERS Provider. Ca10ERTS Inc, CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 08:42:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #3(3475) Calculation DateTme: 08:41, Mon, Nov 20, 2017 Page 10 of 13 Calculation Description: Title 24 Analysis Input File Name: Lennr404.ribdl6x SLAB FLOORS 01 02 OS 04 05 _ 06 07 Name - Zone Area (ftz) Perimeter (ft) Edge Insul. R-value tL Depth Carpeted Fraction Heated Slab -on -Grade living/Guest 1955 107 None O,8 No Slab -on -Grade 2 Bedrooms 1520 177 None - D.8 No Garage Slab Garage_ 645 82 None 0 No BUILDING ENVELOPE -HERS VERIFICATION 01 _ 02 03 04 Quality Insulation Installation (011) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required - Na WATER HEATING SYSTEMS 01 - 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction I%) DHWSYs1 DHW Recirculation with demand eontrol, "rv'. DHWHvatv1 1 (1) 1 .0% WATER HEATERS .. cL R R . I...... 01 02 .... 03 y� "�LiOd 1-0- _...,. OS ,.. _ _--.......N -j 'O6' - ., _07 Y_. A06 ." 0- 10 11 12 Name Heater Elemen. Type Tank Type '+1 Number of Units i` f -- Tank Volume (gal) I i > I Uniform Energy Factor Energy Factor 1. Efficiency (npfit Ra(ing Pilot / Thermal Efficiency 1 V Tank L-,' Insulation R-value .(IntlExt) IfStandby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand/Model Tank Location or Ambient Condition DHW Heater 1 Gas Consumer Instantaneous F) 1 0 0.92 UEF 199,90D Btu/hr 0 n/a 10 GPM n/a n/a SPACE CONDITIONING SYSTEMS . 01. _ _ - 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC - Living/Guestl Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - Bedrooms2 Other Heating and Cooling System Heating Component 2 Cooing Component 2 HVAC Fan 2 Air Distribution System 2 Registration Number. 217-PDiDV24B47D.000.000-0000000-000o Registration DateMme: 2017-11-2012:19:39 HERS Provider. CaICERTS Inc, CA Building Energy Efficiency Standards- 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 08:42:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #3(3475) Calculation DateRme: 08:41, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr404.ribdl6x CF1 R-PRF-01 Page 11 of 13 HVAC - HEATING UNIT TYPES O1 _ .... Q2 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntriFumace - 2 92 AFUE Heating Component 2 CntrlFumace 1 92 AFUE HVAC - COOLING UNIT TYPES 01 02 _ " _ 03 - 04 OS 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 2 12 14 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplilAirCond 1 12 14 Zonally Controlled Single Speed Cooling Component 2 Com of HVAC COOLING - HERS VERIFICATION 01 - 02 03 04 OS 06 Name Yorified,AlAlaw ,.<�$ '' - ""` ge AirQ"o argat�'* M - Varifie Et - ♦ Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool RagijJred ^+�+*'' 0:. "-"" �- Raqu)r4Qt S X* n 4 NotRoquirod Required. Coo9rir� Gomponcnt 2-hers-cool l = ,t RegUirgd , s 1 -� 273� F{ (, } �% Req{tlre'd — Not Required Required HVAC - DISTRIBUTION SYSTEMS -..... 01 02 - 03 04 06 06 .. " 07 Name - Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctslnAll Speed Lower Leakage Target 6 Conditioned zone None Air Distribution System 1-hers-disc Air Distribution System 2 DuctslnAll Specified Lower Leakage Target 6 Conditioned zone None Air Distribution System 2-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 - 02 03 04 06 - 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) " Verified Duct Location Verified Duct Design - - Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required - 5.0 Required Not Regtlirod Not Required Not Required Required Air Distribution System 2-hers-list Required 5.0 Roqulred Not Required Not Required Not Required Required Registration Number 217-P010024847D-000-OMOOODOOD-0000 Registration DateMme: 2017.11-20 12:19:39 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 08:42:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranci 2017 - Plan #3(3475) Calculation DatefTime: 08:41, Mon, Nov 20, 2017 Page 12 of 13 Calculation Description: Ttle 24 Analysis Input File Name: Lennr404.dbdl6x HVAC-FAN SYSTEMS 01 _ 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 - - - Single Speed PSC Furnace Fan 0,56 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2-hers-fan HVAC FAN SYSTEMS -HERS VERIFICATION 07. 02 - 03 _. Name Verified Fan Watt Draw Required Fan Efficiency (Walla/CFM) HVAC FEn 1-hers-fan - - Required 0.58 HVAC FEn 2-hers-fan. Requited 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit - IAQ CFM IAQ Watts/CFM IAQ Fan Typo IAQ Recovery leTfodivenes5('6) HERS Verification SFam IAQVenlRpl 72 .r cu y, .. iUTS t'­ktx a ax -; n Default 0 Required Registration Number 217-P010024947D-000-000-0000000-0000 Registration DateTme: 2017-11.2012:19:39 HERS Provider CeICERTS Inc. CA Building Energy Efficiency S-andards - 2015 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2017-11-20 08:42:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Gruen Ranch 2017 - Plan #3(3475) Calculation DaterTme: 06:41, Mon, Nov 20, 2017 Page 13 of 13 Calculation Description: Tide 24 Analysis Input File Name: Lennr404.ribdl6x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT - - 1. I certify that this Certificate of Compliance documentation Is accurate and complete. Documentation Author Name: - Documentation Author Signature /22 Rick Maurer' Company: - Signature Date Rick Maurer Title 24, Inc. 2017-11 20 12:18:54 A .L�`l, Address: CEAIHERS Certification Identification (If sppliDab 7544 Saddlehill Trail R13-90-10024 City/Stale/Lip: - - - Phone. Orange, CA 92869 714-771-1507 RESPONSIBLE PERSON'S DECLARATION STATEMENT - I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design Identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications Identified on this Certificate of Compliance conform to the requirements of Title 24. Part 1 and Part 6 of the California Code of Regulations, 3. The building design features orsyslem design features identified on this Certificate of Compliance are consistent with the Information provided an other applicable compliance documents, worksheets, calculations, plans and specifications submitted jglbe oMdreoinent ogency,for approval with this budding parmlt appllcalion. Responsible Designer Name: mr"' P 9 �,,, Pd �.. RaspOnjibla pesiggor Slgratura:'°r James Jenike ��«, � +�. R P y .. Corn an ' 1'' f _tSigned, Date ' - Lennar Homes -Southern CA 2017-1-1-20)2:19:3 - Address: License: 980 Montecito Drive, Suite 302 Citylstatelzip: Phone: Corona, CA 92879 951-817-3500 I Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration I �' Provider responsibility for the accuracy of the information. Easy to VerBy at CaICERTS.com Registration Number. 217-Po10024a47D-000-000-000000D-ooaD Registration DaleMme: 2017-11-2012; 19:39 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards- 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 08:42:25 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - Plan #3(3475) Date 11/20/2017 System Name HVAC - Living/Guest Floor Area 1,955 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 1,183 0 COOLING PEAK COIL HTG. PEAK System Sensible Latent CFM Sensible -Heating Output per System 48,000 25,026 2,630 520 20,433 Total Output Btuh 96,000 0 Output Btuh/s ft 49.1 387 252 System 0 0 .Cooling Output por System 36,000 0 0 0 0 Total Output Btuh _ 72,000 0 387 1 25,800 2,630 0 Total Output Tons 6•0 252 Total Output Stuhls 36.8 Total Output s 'ftlTon 325.8 1 20,937 Air System CFM per System 1,400 HVAC EQUIPMENT SELECTION Airflow cfm 2,800 Liv/Gst.HVAC Equipment Selection & Sizing by Othc 47,309 13,463 96,000 96,000 Jan 1 AM Airflow cfm/s ft 1.43 Airflow cfmfTon 466.7 Outside Air % 0.0/0 Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 47,309 13;463 Outside Air cfmis ft 0.00 Note: values above given Iat ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 IF 68 OF 68 OF 105 OF Outside Air 0 cfm Supply Fan Heating Coil 2,800 cfm 68 OF Set 4 �1 A 4 ll 105 OF I ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112178OF 75/62°F 75/62°F 55/54°F —►— Q _ —► Outside Air 0 cfm Supply Fan Cooling Coil 2,800 cfm 76162 of _ _ 11711 55 / 54 OF 47.3% ROOM ' 75 162 OF EnergyPro 7.2 by EnergySolt User Number. • 1686 ID: Page 16 of 17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date 11/20/2017 Lennar Homes - Plan #3(3475) System Name Floor Area HVAC - Bedrooms 1,520 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,061 Return Vented Lighting Return Air Ducts Return Fan Ventilation 7 0 Supply Fan Supply Air Ducts COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 80,000 22,422 21045 520 20,407 Total Output Btuh 80,000 0 Output Btuh/s ft 52.6 347 251 Cooling System 0 0 Output perSystem 60,000 0 01 0 0 Total Output Btuh 60,000 0 347 0 Total Ou ut. Tons 5.0 251 Total Output Btuh/s ft 39.5 TOTAL SYSTEM LOAD 23,117 2;045 Total Output s ft/Ton 304.0 1 20.910 Air System CFM perSystem 2,200 HVAC EQUIPMENT SELECTION Airflow cfm 2,200 Bed. HVAC Equipment Selection & Sizing by Others 40,081 10.563 80,000 Airflow cfm/s ft 1 A5 Airflow cfmrron 440.0 80,000 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) 40,081 10,563 0.00 Outslde.Alr cfm/s ft _ TIME OF SYSTEM PEAK Jan 1 AM Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 68 OF 105 OF n Outside Air E1 0 cfm Supply Fan Heating Coil 105 IF 2,200 cfm ROOM . AN 68 OF 68 °F AT-1-1 COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112178 OF 75 / 62 IF 75 / 62 OF 55 / 54 OF Outside Air 0 cfm Supply Fan Cooling Coil 55 / 54 OF 2,200 cfm _ " Cf 47.2% f ROOM 75 162 OF 75162 °F 4 OT�� EnergyPro 7.2 by EnergySoft User Number. 1686 ID: Page 17 of 17 BUILDING ENERGY ANALYSIS REPORT PROJECT: Lennar Homes - Plan #4(3818) Griffin Ranch 2017 La Quinta, CA Project Designer: Lennar Homes 980 Montecito Drive, #302 Corona, CA 92879 951-817-3600 Report Prepared by: Rick Maurer Rick Maurer Title 24 7544 Saddlehill Trail Orange, CA 92869 714-771-1507 Job Number: Date: 11 /14/2017 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. TABLE OF CONTENTS Cover Page Table of Contents Form CF-IR-PRF-01-E Certificate of Compliance HVAC System Heating and Cooling Loads Summary Energypro• 72,by EnergyS dit Job Number: 1D: User Number: 1686 1 2 3 13 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan *4(3818) Calculation DateTme: 14:49, Tue, Nov 14, 2017 Calculation Description: Tile 24 Analysis Input File Name: Lennr405.ribdl6x CF1 R-P RF-01 Pagel of 10 GENERAL. INFORMATION Project Name Grifn Ranch 2017 - Plan N4(3818) Cal:ulation Description Title 24 Analysis K04 . Project Location Griffin Ranch 2017 City La Ouinta 06 Standards Version Compliance 2017 Zip Code 07 Compliance Manager Version BEMCmpMgr2016.3.0(934SP1) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (doglCardinal) Cardinal 12 - - Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total C end. Floor Area.(ft2) 3818 16 Numberof Zones 1 16 2 Slab Area (R ) 3818 17 Numberof Stories 1 18 Addition Cond. Floor Area(hz) n/a 19 Natural Gas Available yes 20 Adiitlon Slab Area (ftJ nla 21 Glazing Percentage (%) 18.8% COMPLIANCE RESULTS Ot Building Complies with Computer Performance.-- 02 This building incorporates features that fegdire.fietd testing andlor.variscalloktiy 4"iiod HPRS nit0(;undet A supervision of a CEC-approved HERS provider. -'�-BA+i 03 .This •• s4 building ineoryarates one ormare S{spdal Faatiaessho�wn tiNow { a-_ Registration Number: 217-PO10024656D.00MOo-000000e-0000 Registration DateRme: 2017-11-20 12AB:34 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CFIR-09012017-934 SP1 Report Generated at: 2017-11-1414:50:16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #4(3818) Calculation DateMme: 14:49, Tue, Nov 14, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr405.ribdl6x CFI R-PRF-01 Page 2 of 10 ENERGY USE SUMMARY Energy Use Energitt-se Standard Proposed Compliance Percent Design Design Margin Improvement Space Heating 1.66. - 1.98 - -0.32 -19.3% Space Cooling 82.30 65.53 16.77 20.4% IAQ Ventilation 0.91 0.91 0.00 0.0% Water Heating 3.73 3.49 0.24 6.4% PV Credit - 0.00 0.00 - North Facing Compliance Total 88.60 71.91 10.69 18.8% Space Heating 1.66 1.88 - -0.22 -13.3% Space Cooling 82.30 66.55 15.75 19.1% IAQ Ventilation 0.91 0.91 0.00 0.0% Water Heating 3.73 3.49 0.24 6.41A PV Credit - 0.00 0.00 - East Facing Compliance Total 89.60 72.83 15.77 17.8 /. Space Heating Space Cooling 1.66.. " vfi 3 F E 2.22 >-� 0.46 -0.56 11.84 -33.7% 14.4% IAQ Ventilationk, " U a�• ■0.000.0% 9 �����bbb D 6.4% Water Heating `1 3. 3 9 0.24 PV Cred0 ...; '::- i C_opo I ;. FZ 0.00 - South Facing Compliance Total 88.60 77.08 11.52 13.0% Space Healing 1.66 - - 2.45 -0.79 -47.6% Space Cooling 82.30 65.64 16.46 20.0% IAQ Ventilation 0,91 0.91 O.DO 0.0% Water Heating 3.73 3.49 0.24 6.4% PV Credit -- 0.00 O.DO - West Facing Compliance Total 88.60 72.69 15.91 18.0% Registration Number: 217-P010024856D-000-0004000000-0OW Registration DateMme: 2017-11-2012'.48.34 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version-CF1R-09012017-934 SP1 I HERS Provider CalCERTSInc. Report Generated at 2017-11.14 14:50:16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #4(3818) Calculation Date/Time: 14:49, Tue, Nov 14, 2017 Page 3 of 10 Calculation Description: Title 24 Analysis Input File Name: Lennr405.ribdl6x ENERGY DESIGN RATING Energy Design Rating (EDR) Is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006Interiational Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" Its TDV energy. Because EDR Includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), It is not used to show compliance with Part 6 but may Instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards Is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building Is provided for Information. Simllarty, the EDR score of the Proposed Design Is provided separately from the EDR value of Installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR North 62.8 45.2 0.0 45.2 East - - - 52.8 45.6 0.0 - - 45.6 South 62.8 47.6 D.0 47.6 West 52.6 4C6 0.0 45.6 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.11 and QII verification prerequisite. ❑ Design meets Ter 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite, ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family In climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.31 Including on -site photovoltaic (PVi renewable energy generation sufficient to achleve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. ., Notes: 7 r stt; V j ..d't e) • Excess PV Generation EDA Credit: Bypassing PV slie limit May vio.Aet FAA MeteringNEM rdos REQUIRED SPECIAL FEATURES The following are features that must he installed ascondiiflpn for meeting thetnodeted energy performance fef This Cori putei analysis • Nonstandard roof reflectance • Insulation below roof deck • Window overhangs andforfins • Non-standard duct location (any location other than attic) • Recirculation with demand control, push button Registration Number 217-P010024056D-000-000.0000000-0000 Registration DateTme: 2017.11-2012:48:34 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-09012017-934 SPt Report Generated at: 2017-11-14 14:50:16 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #4(3818) Calculation DateMme: 14:49, Tue, Nov 14, 2017 Page 4 of 10 Calculation Description: Title 24 Analysis Input File Name: Lennr405.ribdl6x HERS FEATURE SUMMARY The follovAng is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided In the building components tables below. Bullding-level Verifications: • High quality Insulation Installation (011) • IAO mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER •: Verified Refrigerant Charge r Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Ducts located entirely In conditioned space confirmed by duct leakage testing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: — None — BUILDING - FEATURES INFORMATION 01 02 03 04 06 e6 07 Nul"ber of 0waging' "`" '` 't '" Number of Ventilation Number of Water Heating Systems Project Name Conditioned Floor"(BZ) Humber,of,0odrooms Numbero zOagoYfv Cooling Systems Griffin Ranch 2017 - Plan #4(3818) 3018.,,. ")•. ` �„„,,1 '''r-.�,,,,,. .,..., d.? - st 1 #•.. 0 1 • ZONE INFORMATION - "`�+`s,� !"` r"i c'1 1'"1 °, iSa7 i „,). 01 02 03 04 05 06 07 Zone Floor Area Avg, Ceiling Zone Name Zone Type HVAC System Name (ft2) Height Water Heating System 1 Water Heating System 2 House Conditioned HVAC7 3818 12 DHW Sys 1 nla Registration Number: 217•P070024856D-000-000-0000000-0000 Registration DaleRme: 2017-11-2012:48:34 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-0901 2017-934 SPt Report Generated at: 2017-11-14 14:50:16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name* Griffin Ranch 2017 - Plan #4(3818) Calculation DateMme: 14:49, Tue, Nov 14, 2017 Page 6 of 10 Calculation Description: Tide 24 Analysis Input File Name: Lennr405.ribdl6x OPAQUE SURFACES 01 02 03 04 05 06 07 09 Name Zone Construction Azimuth Orientation Gross Area (ft) Window 6 Door Area (ft2) Tlft (deg) Front 2x6 Wall House R-21 Wall 0 Front 660 100 90 Left 2x6 Walt House R-21 Wall so Left 990 420 90 Back 2x6 Wall House R-21 Wall 180 Back 980 152 90 Right 2x6 Wall - - - House R-21 Wall 270 Right 730 68 90 Front Garage Wall House»_Garage_ R-15 Wall House/Garage Na Na 220 21 We Right Garage Wall House»_Garage_ R-15 Wall House/Garage n/a - rda 140 0 n/a Right 2x8 Garage Wall House». Garage_ R-21 Wall House/Garage n/a Na 120 0 Na Ceiling Below Attic House R-30 Attic HPA nla We 3818 nla n/a FG Wall - - _Garage_ R-0 Wail 0 Front 220 128 90 LG Wail _Garage_ R-0 Wall 90 Left 100 - 0 90 RG Wall _ _Garage_ R-0 Wall 270 - Right 360 0 90 Garage Ceiling _Garage_ R-0 Garage Attic - We - n/a 617 n/a W. ATTIC r i.i to' - E .. 1 y 01 . 02 `'" W. - ,. 04., i °, Oi.„, - 06 07 08 Name Construction -` ' Type ✓.r 'RoolRise�v` `Rad(Roflde'tanco RoofEmittanee Radiant Barrier 1 Cool Roof Attic House Attic RoolHouse Unventilated 3 0.16 0.89 No No Atlic_Garage_ .Attic Garage Roof Cons Ventilated 3 0.16 0.89 No No Registration Number 217-P010024956P)00-000-0000000-0000 Registration DateRme: 2017-11-201246:34 HERS Provider. CaICERTS inc, CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017.934 SP1 Report Generated at:2017-11-14 14:50:16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #4(3818) Calculation DateTme: 14:49, Tue, Nov 14, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr405.ribd16x CF1 R-PRF-01 Page 6 of 10 FENESTRATION I GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type_ Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (ftz) U-factor. SHGC Exterior Shading Front Operable Window Front 2x6 Wall (Front-0) - - 1 60.0 0.30 0.23 Insect Screen (default) Front Fixed Window Front 2x6 Wall (Front-0) - 1 8.0 0.26 0.25 Insect Screen (default) Front Openable 2 Window Front 2x6 Wall (Front-0) - - 1 8.0 0.30 - 0.23 Insect Screen (default) Left Operable Window Left 2x6 Wall (Left-90) -: - 1 38.0 0.30 0.23 Insect Screen (default) Left Fixed Window -Left 2x6 Wail (Left-90) - - 1 22.0 0.26 0.25 Insect Screen (default) Left Stacking Glass Door Window Left 2x6 Wall (Left-90) 12.0 10.0 1 120.0 0.32 0.20 Insect Screen (default) Left Stacking Glass Door 2 Window Left 2x6 Wan (left-90) 24.0 10.0 1 240.0 0.32 - 0.20 Insect Screen (default) - Back Openable Window Back 2x6 Well (Back-180) - - 1 72.0 .0.30 0.23 Insect Screen_(defaul) Back Openable 2 Window Back 2x6 Wall (Back-180) - -- 1 8.0 0.30 0.23 Insect Screen (default) Back Stacking Glass Door Window Back 2x6 Wall (Bade 1B0) - 9.0 8.0 1 72.0 0.32 0,20 Insect Screen (default) Right Operable Window Right 2x6 Wall (Right-270) - .- 1 68.0 0.30 0.23 Insect Screen (default) OPAQUE DOORS r^ 01 - . 03 04 Name 31d. 1 . t� s'^� !" SI eof Bulldi- d - (19. , � 1 c-. r * t-, - Area (ft2) U-factor - Front Door ' Front 2x6 �Afalf" 24.0 0.50 Front Garage Door Front Garage Wall 21.0 0.50 Car Door FG Wall 128.0 0.50 OVERHANGS AND FINS 01 02 03 04 05 -. 06 07 08 09 10_ 11 12 13 1 14 - Overhang Left Fin Right Fin - Window - Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L sot Up Depth. Top Up Dist R Bot Up Left Stacking Glass Door 12 1 2 2 0 0 0 .. 0_ b 0 0. 0 0. Left Stacking Glass Door 2 12 1 2 2 0 0- 0 0 0 0 0 0 0 Back Stacking Glass Door 12 3- 2 2. 0 0 0 0 0 0 0 D 0 Registration Number. 217-P010024e56D-000-000-0000000-0000 Registration DateMme: 2017A1-20 12:4a:34 CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 e HERS Provider. CaICERTS Inc. Report Generated at: 2017-11-1414:50:16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan R4(3818) Calculation Date/Time: 14:49, Tue, Nov 14, 2017 Calculation Description: Tit)e 24 Analysis Input File Name: Lennr405.ribdl6x C F1 R-PRF-01 Page 7 of 10 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 06 06 . - - 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers Ceilings (below Inside Finish: Gypsum Board R-0 Garage Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: no insul. /2x4 • Inside Finish: Gypsum Board • Cavity/Frame: noinsul./2x4 R-0 Wail Exterior Walls - Wood Framed Wall 2x4 @ 16 in. O.C. none 0,361 ExterforFinish: 3 Coat Stucco Cavity/Frame: no insul. /2x4 Top Chrd • Roof Deck: Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling In. O.C. none 0.400 Roaring: 10 PSF (RooTle) a Around RoofJolsts: R-17.0 insul. • Cavity/Frame:R-13.0/2x4Top Chat • Roof Deck., Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic RoofHouse Attic Roofs Wood Framed Calling In. O.C. R30 0.040 Rooring.10PSF(Roofriie) Ceilings (below " Inside Finish: Gypsum Board R-30 Attic HPA attic) wood FramuG' Ittng . �; �r1"r2z4 Pd h} S`.C.%t none') • • Q.481 Cavity/Frame: no 1nsuL /2x4 4l 3 '"'�• i IL • - Inside Finish: Gypsum Board �' Cavrty /Frame: R-21/2x6 R-21 Wall Exterior Walls dVood Framed Wall ,24 @ 19 in Q.C. r.,, .R 21 r0.069 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board • Cavity/Frame: R-15/2x4 R-15 Wall House/Garage Interior Walls Wood Framed Wall 2x4 @ 16 In. O.C. R 15 0,088 Other Side Finish: Gypsum Board • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 R-21 Wall House/Garage Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.064 Other Side Finish: Gypsum Board SLAB FLOORS 01 02 03 04 06 06 07 Name Zone Area (fl2) Perimeter (it) Edge lnsul. R-value 6 Depth Carpeted Fraction Heated Slab -on -Grade House 3818 286 None 0.6 No Garage Slab Garage_ 617 66 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (011) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required) - Not Required Not Required n/a Registration Number. 217-Po10024e56D-000-000-0000000-0000 Registration Date/rime: 2017-1/-2012:48:34 HERS Provider. CeICERTS Mc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SPt Report Generated at: 2017-11-14 14:50:16 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Griffin Rench 2017 - Plan #4(3818) Calculation DateMme: 14:49, Tue, Nov 14, 2017 Page 8 of 10 Calculation Description: Title 24 Analysis Input File Name: Lennr405.ribdl6x WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Recirculationcontrol, sht huff or DHW Heater 1 (1) 1 .0% WATER HEATERS 01 02 03 04 05 06 ... 07 08 .__. 09 10 11 - 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor Energy Factor Efficiency Input Rating Pilot / Thermal Efficiency I Tank Insulation R-value (InUExt) Standby Loss / Recovery EH First Hour Rating I Flow Rate NEEA Heat Pump Brand I Model Tank Location or Ambient Condition DHW Heater 1 Gas Consumer Instantaneous (UEF) 1 0 0,92 UEF 199,900 Btulhr 0 rda 10 GPM n/a n/a SPACE CONDITIONING SYSTEMS - 01 02 03 - 04 05 06 SC Sys Name - - 8ystemiType ,;. ,;:"Heatlrig�UnitName y ., Looting Unit Name - .pp _ Fan Name Distribution Name HVAC1 Othei,HeatingandCoolmg ,:II SYs{am .ya LN•C r. ✓ `' P'' ii :Healing Component 1 tr -,. n, _. Cooling C�Imponent t F L' A ii �r HVAC Fan 1 is Air Distribution System 1 HVAC -HEATING UNIT TYPES "` .•. j '� { f j'+ ». '„ - { j..:1 ( . 01 02 .. 03 _ _04 Name .System Type NumberofUnits Efficiency Heating. Component 1 CnbiFurnace 2 92 AFUE HVAC -COOLING UNIT TYPES 01 02 03 04 05 O6 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Goofing Component 1 SplitAirCond 2 12 14 Not Zone[ Single Speed Cooling Component 1-hers-mal HVAC COOLING -HERS VERIFICATION. 01 02 03 04 05 - 06 • Name Verified Alrflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 - - - - Required Not Required Required Registration Number 217-P010024856D-000-000-000000o-0o00 Registration Dalerrime: 2017-11-20 12A8:34 HERS Provider. CaICERTS Inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at 2017-11-1414:50:16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #4(3818) Calculation Date/Time: 14:49, Tue, Nov 14, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr405.dbdl6x C F1 R-PRF-01 Page 9 of 10 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuUslnAll Specified Lower Leakage Target 6 Conditioned zone None Air Distribution System 1-hers-disc HVAC DISTRIBUTION - HERS VERIFICATION 01 02 _,. .. 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Vertfied Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hersdist Required 5.0 Required Not Required Not Required Not Required Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (WaftstCFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 ei" ,. ` }� 1# iM02 . i(i. a "` ?� f. OS Name '^2t},;. avt .7µs v."" SVcrifiod Fan Watt Draw' F_. " Required Fan Efficiency (WaNsICFM) HVAC Fan 1-hers-tan 't t ""° "� ; • RegWeil.i I. r i 0.58 IAQ (Indoor Air Quality) FANS 01 02 - - 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS. Verification SFam IAQVentRpt 76 0.25 Default 0 Required Registration Number 217-P010024856D-000-000-0000000-0000 Registration Date(nme: 2017-11-20 12:46:34 CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version-CFiR-09012017-934 SPt HERS Provider: CoICERTSIn.. Report Generated at: 2017-11-14 14:50:16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Griffin Ranch 2017 - Plan #4(3818) Calculation DateMme: 14:49, Tue, Nov 14, 2017 Page 10 of 10 calculation Description: Title 24 Analysis Input File Name: Lennr405.ribdl8x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. - Documentation Author Name: Documentation Author Signatum,- Rick Maurer Company. Signature Date: - Rick Maurer Title 24, Inc. 2017-11-20 12:48:04 j—+RF C Address: CEA/HERS Certification Identification (If applicabl -cA iRNr4r.ryyGevwtl r..u.4r tm+t+rkt. 7544 Saddiehill Trail R13-90-10024 City/StataopE . _.. -Phone: ... - Orange, CA 92869 714-771-1507 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penally of perfury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 cerliry that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The budding design features or system design features Identified on this Certificate of Compliance are consistent wdh the Wormalion providedan other applicable compliance documents, worksheets, calculations;,plans.and specifications submitted to.the enforcement agOncy;.(orap{ttoval wllh,:dlis bul,Iding pa,(tnit app0catlon.. Responsible Designer Name: a `' .a. Responifi)le Designer SigMit e James Jenike Company:a l..1 Date Signed: Lennar Homes - Southern CA 2017-11-20 12:4834 Address: License: .. - 980 Montecito Drive, Suite 302 City/Staleop: - Phone: Corona, CA 92879 951-817-3500 Digitally signed byCaICERTS. This digital signature is provided in order to secure the content of this registered document, and In noway Implies Registration - Provider responsibility for the accuracy of the information. Easy to Verity at CaICERTS,com Registration Number. 217.POI0024e56D-Ooo-000-0000000.0000 Registration DateRme: 2017-11-20 12:48:34 HERS Provider CaICERTS irw. CA Building Energy Efficiency Standards- 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2017-11-14 14:50:16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - Plan #4(3818) Date 11/14/2017 System Name HVAC Floor Area 3,818 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 2,284 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible . Latent CFM Sensible Output perSystem 64,000 48,177 5,137 1,043 40,928 Total Output Btuh 128,000 0 Output Btuh/s Ft 33.5 746 504 Cooling System 0 0 Output per System 48,006 0 0 0 0 Total Output Btuh 96,000 0 746 49,669 5,137 0 Total Output Tons 8•0 504 Total Output Btuh/s 25.1 Total Output (sgftFFon) 477.3 41,937 Air ;System CFM per System 2.000 HVAC EQUIPMENT SELECTION Airflow cfm 4,000 HVAC Equipment Selection & Sizing by Others 61,584 19,621 128,000 Airflow cfm/s ft 1.05 Airflow cfm/Ton 500.0 Outside Air (%) 0.0% Total Adjusted System Output (gusted for Peak Design conditions) TIME OF SYSTEM PEAK 61,584 19,621 126,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak " 26 IF 68 OF 68 OF 105 OF �' -► Outside Air [FEE-1-u cfm Supply Fan Heating Coil 4,000 cfm 68 OF 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak) 112 / 78 OF 75162OF 75162 OF 55154 OF ii Outside Air ��----�^��-^--- 0 cfm Supply Fan Cooling Coil 55154 OF 4,000 cfm 47.7% RooM JU 75162 IF 75162 IF LE 1 ' EnergyPro 7.2 by EnergySoft User Number. 1686 ID: Page 13 of 13 BUILDING ENERGY ANALYSIS REPORT PROJECT: Lennar Homes - Plan #5(4154) Griffin Ranch 2017 La Quinta, CA Project Designer: Lennar Homes 980 Montecito Drive, #302 Corona, CA 92879 951-817-3600 Report Prepared by: Rick Maurer Rick Maurer Title 24 7544 Saddlehill Trail Orange, CA 92869 714-771-1507 Job Number: Date: 11 /20/2017 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software —www.energysoft.com. TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 HVAC System Heating and Cooling Loads Summary 15 IEnergyPro 7.2 by EnergySoft Job Number. ID: User Number. 1686 1 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #5(4154) Calculation DateMme: 08:46, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr396.ribdl6x CF1 R-PRF-0l Pagel of 12 GENERAL. INFORMATION 01 Project Name Griffin Ranch 2017 - Plan 05(4154) 02 Calculation Description Title 24 Analysis 03 - Project Location Griffin Ranch 2017 04 City La Quints OS - - Standards Version Compliance 2017 06 Zip Code 07 - Compliance Manager Version. BEMCmpMgr 2016.3.0 (934 SP1) 06 ClimateZorle CZ15 09 SOftvrere Version EnergyPro 7.2 10 .. Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope NgvAy Constructed 13 - Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 4154 16 Numberot Zones 2 16 Slab Area (ft2► 4154 11 Number of Stories 1 1s Addition Cond. FloorAPea(ftz) We 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) n/a 21 Glazing Percentage (1t) 20.3% COMPLIANCE RESULTS 01 Building Complies with Computer Performance h 02 This bullring incorporates features lhahroquire fielA testing and/q%v ji0cetion;tiy'a.-reNfiod HORS rirtqunder op sii"pai, (*6.of a CEC-approved HERS provider. 03 This building incorporates one of motil�Spodai Foalu>•esshoivn tirtibw ' !' Registration Number 217-P010024971E-000-000.0000000.0000 Registration DaleRme: 2017-11-2012:19;41 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 08:47:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #5(4154) Calculation DateMme: 08:46, Mon, Nov 20, 2017 Calculation Description: Tille 24 Analysis Input File Name: Lennr396.ribdl6x CFI R-PRF-01 Page 2 of 12 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDVe-yr) Design Design Margin Improvement Space Hefting _ 1.21 1.31 -0.10 - .6.3% Space Coc ling 79.99 6225 17.74 22.2% IAQ VenllEtion 0,96 0.96 0.00 0.0% Water Heating 3.95 3.67 0.28 7.1% PV Cred.t - 0.00 0.00 - North Facing Compliance Total 86.11 68.19 17.92 20.8%. Space Heating 1.21 1.64 .0.43 -35.5% Space Cooling 79.99 69.96 10.03 12.5% IAQ VentilEtlon 0.96 0.96 0.00 0.0% Water Heating 3.95 3.67 0.28 7.1% PV Cred3 - 0.00 0.00 - East Facing Compliance Total Kill 76.23 9.86 11.6% Space Heeling 121 1.82 -0.61 - -50A% SpaceCocling IAQ VenlilEtion �9 C RTI& 0: 6������ Inc 1900 0.00 2.0 % 0.0Water Heating `a`-3:67y E 0,28 7.1% �� 46 4 i F R 0.00 - PV Credit South Facing Compliance Total > 86.11 66.82 19.29 22.4% Space Heating 1.21 1.63 -0.42 -34.7% Space Cooling 79.99 69.75 10.24 12.8% IAQ Ventilation 0.96 0.96 0.00 0.0% Water Heating 3.95 3.67 0.28 7.1% PV Credit - 0.00 0.00 - West Facing Compliance Total $6.11 76.01 10.10 11.T*A Registration Number: 217-P0100249T1E-000*00-0000000-0000 Registration DateMme: 2017-11-2012:19:41 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards-2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 08:47:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #5(4154) Calculation Date/Time: 08:46, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr396.dbdl6x CFI R-PRF-01 Page 3 of 12 ENERGY DESIGN RATING Energy Design Rating (EDR) Is on alternate way to eipross the energy Performance of a bu9ding using a scoring. system Where 100 represents the energy performahce of the Residential ofthe Energy Conservation -dodo (IECC) with California modeling assumptions. A;score of zero represents, Energy Services (RESNET) reference home eharaclertiatlon 2006 lntemationat the energy Porteimanco-of a building that combines high levels of energy eNictancy with reneviabin generation to"zero out,"_Its TOV onergy: Decause-EDR includes consideration of 'used components. -not regulated by Title 24, Part 6 (such as domesticappliancesand consumer olectronIds ); it is no to show compliance with Part 6 but may Instead beusedby local )urisdictlonspursuing local ordinances underTitle 24,_Part 11 (CALGrocO). As a -Standard Design building under the 2016 Building Energy Efticlency Standards Is,slgrdfieantly more efficient than the baseline EDR building, the pDR of the.Standgrd Oosigri buliding: is: provided for Information. Similarly, the EDR scone of the Proposed Design ls'provided separately from the EDR vatgo of installed PV so that the effects. of etfictencyand renewable crier y"can both be seen - - EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR North 54.1 45.7 0.0 45.7 East 54.1 - - 49.5 - 0.0 49.6 South 54.1 45.1 0.0 46.1 - West 54.1 - 49.4 0.0 .. _ 49.4 ❑ Design meets Tier I requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and Qli verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203AM2) and QII verification prerequisite. Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) Including on -she ❑ photovoltaic (PV) renewable energy generationsuNiclent to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. Notes: t�i .r {i • Excess PV Generation EDR Credit: Bypassing PV slie limit ins .vi0latc�IN! 6ergyfXotcrin �JEfAI les is r. REQUIRED SPECIAL FEATURESn ` r e r p r. �• . + r i -• r' i ' tormeoUng energy PeAormarice instills eori puld'r anely`sis.' ' The following are features that must be installed as condition theLniodeleu • Nonstandard roof reflectance • Window overhangs and/orfins • Nonstandard duct location (any location other than attic) • Recirculation with demand control, push button Registration Number 217-P010024971E-000-000-0000000-0000 Registration DateMme: 2017-11.20 12:19:41 HERS Provider. CaICERTS fnc, CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-0901 2017-934 SP1 Report Generated at: 2017-11-2008:47:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #5(4154) Calculation DateTme: 08:46, Mon, Nov 20, 2017 Page 4 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr396.ribd 1 6x HERS FEATURE SUMMARY The following is a summary of the features that must be field-veri0ed by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Bullding4evel Verifications: • High quality insulation Insta.lation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified Refrigerant Charge • Fan Efficacy WattsfCFM HVAC Distribution System Verifications: • Duct Sealing • Ducts located entirely in conditioned space confirmed by duct leakage testing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: —None — BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 ONomber of 6we0ing` �""` 1"l' v °�` -' Number of Ventilation Number of Water Heating Systems Project Name Conditioned Floor Arew.(R2)� +'"'Unifs ` Nulilbi rof Bodio Numbieey of 2onesir"* Cooling Systems Griffin Ranch 2017 - Plan #5(4154) 4154„- & c.•..: „1 a.,;,.....• j1 �$ �H d' P 2 �` 0 1 ZONE INFORMATION t�..- 01 02 03 04 os 06 07 Zone Floor Area Avg. ceiling Zone Name Zone Type HVAC System Name (ill) Height Water Heating System 1 Water Heating System 2 Living Conditioned HVAC - Living'! 2204 12 DHW Sys i - n/a Bedrooms Conditioned HVAC - Bedrooms2 1950 12 DHW Sys 1 nfa Registration Number. 217.P0100:4971E-000-000-0000000-0000 Registration DateMme: 2017-11-20 12:19:41 HERS Provider. CaiCERTS Inc CA Building Energy Efficiency Standards-2016 Residential Compliance Report Version - CF1R-09012017-934 SPt Report Generated at: 2017-11-20 08:47:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #5(4154) Calculation DateTme: 08:46, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr396.dbdl6x C F1 R-PRF-01 Page 6 of 12 OPAQUESURFACES ... 01 02 03 04 05 06 OT - 08 Name Zone Construction Azimuth Orientation Gross Area (ftz) Window tt Door Area {n=) Tilt (deg) Front 2x6 Wail Living -R-21 Wall 0 Front 636 338.704 go Left 2x6 Wall Living, - R-21 Wall 90 Left 108 12.6999 go Back 2x6 Wall Living R-21 Wail 180 Back 312 - 100 90 Right 2x6 Wall Living R-21 Wall 270 Right 48 12.6999 90 Front Garage Wall L1Ang»_Garage_ R-15 Wail House/Garage - n/a n/a 110 21 n/a Right Garage Wall Living»^Garage_ - R-15 Wall House/Garage n/a n/a 140 0 n/a Interior Surface - Living»Bedrooms R-0 Walll We n/a 990 o We Ceiling Below Attic " - living R-30 Attic HPA n/a Ma 2204 n/a - - - - - We Front 2x6 Wall 2 Bedrooms R-21 Wall 0 - Front 192 120 90 Left 2x6Wall 2 Bedrooms R-21.Wall - _ .. 90 ., :. Left 484 44 90 Back 2x6 Wall 2 Bedrooms R-21 Wall 180 Back 704 188.008 90 Right 2x6 Wall 2 Bedrooms ,:. R-21 Wall. 270 Right 432 49.3 90 Front Garage Wall2 8etlrooms?>_.Garage� .� R,15YPa11 Hau.e/Gai•go; rnt silla, „* 1 100 0 -- n/a . . Ceiling Below Attic 2 - - Sedrpojtls 6 R-30 Aldo HpIt ,' , nJu - 1. 1 rtlal �„ 1950 Na n/a FG Wall _Garaget_ ,R-0 Wad From 210 128 90 LG Wall _Garage -, r- ' --- t '- R-0 Wag'. " ^f go -' --"` Litt, r 230 0 90 RG Wall _Garage_ R-0 Wall 270 Right 370 0 90 Garage Caging, _Garago_ R-O Garage Attic nla n/a 678 We -n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Living Attic RoofLiving Unventilated 3 0.16 0.89 No No Attic Bedrooms Attic RoofBedrooms Unventilated 3 0.16 0.89 No No Atlic_Garage_ Attic Garage Roof Cons Ventilated 3 0.16 0.89 - No - No Registration Number: 217-P010024971E-000-000-0000000-0000 Registration DaleRme: 2017-11-2012:19:41 HERS Provider. CaicERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at:2017-11-20 08:47:09' CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Griffin Ranch 2017- Plan #5(4154) Calculation Date/Time: 08:46, Mon, Nov 20, 2017 Page 6 of 12 Calculation Description: Titie 24 Analysis Input File Name: Lennr396.ribd16x FENESTRATION I GLAZING 01. - 02 03 04 05 - 06 1 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height .(R) Multiplier Area (R) U-factor SHGC Exterior Shading Front Fixed Window Front 2x6 Wall (Front-0) 8.0 1.3 1.006 10,7 0.26 0.25 Insect Screen (default) Front Fixed 2 Window Front 2x6 Wall (Front-0) 4.0 6.0 1 24,6 0,26 0.25 Insect Screen (default) Front Folding Window Wndow Front 2x6 Wall (Front-)) - 8.0 5.0 1 40.0 0.32 0.20 Insect Screen (default) Front Stacking Glass Door Window Front 2x6 Wall (Front-0) 24.0 10,0 1 240.0 0,32 0.20 Insect Screen (difraull) Left Operable Window Left 2x6 Wail (Left-90) 2.0 5.0 1 10.0 0.30 0.23 Insect Screen (default) Left Fixed Window Left 2x6 Wall (Left-90) 2.0 1.3 1,015 2.7 0.26 0.25 Insect Screen (default) Back Sliding Glass Door Window Back 2x6 Wall (Baca-180) 8.0 - 8.0 1 64.0 0.28 0.22 Insect Screen (default) Back Operable Wndow Back 2x6 Wall (Back-180) .. 6.0 6.0 1 36.0 0.30 0.23 Insect Screen (default) Right Openable Wndow Right 2x6 Wall (Right-270) 2.0 5.0 1 10.0 0.30 0.23 Insect Screen (default) Right Fixed Window Right 2x6 Wail (Right-270) 2.0 1.3 1.015 2.7 0.26 0.25 Insect Screen (default) Front Slacking Glass Door 2 Window Front 2x6 Wall 2 (Front-0) 12.0 10.0 1 120.0 0.32 0.20 - Insect Screen (default) Left Operable 2 Wndow l,aR°2it-6 Wall 2 ([.6")'�� {i"'""' ("� =�'" "'�- � 1 36.0 0.30 0,23 Insect Screen (default) Left Fixed 2 Window it, Left 2xe y4q.2 (L4-90) "`r' j = `E"- ti 1 11 ¢ 8.0 0.26 0.25 Insect Screen (default) Back Fixed Window "}, �` Back2z0 W3ih2 (Back=le0)'. '' ' yF,'?.A. 1"6,01 ` `-` `:6.0 " 41 x'q6.0 0.26 0.25 Insect Screen (default) Back Fixed 2 Window - A '& 8ac1r2x6 M412 (Ba�dc-180). (� ("•�12.0 _,1 1 f'1,3� A:003 16.0 0.26 0.25 Insect Screen (default) Back Operable 2 Window - Back 2x6 Wall 2 (Bpdt-180) 12.0 6.0 1 72.0 0,30 0.23 Insect Screen (default) Back Oponabio.3 Window Back 2x6 Wall 2 (Back-180) 6.0 3.0 1 1 18.0 0.30 0.23 Insect Screen (default) Back Operable 4 Window Back 2x6 Wall (Back-180) 6.0 6,0 1 36.0 -0.30 0.23 Insect Screen (default) Back Fixed 3 Window Back 2x6 Wall 2 (Beck-180) - 5.0 2.0 1 10.0 0.26 025 Insect Screen (default) Right Openable 2 Window Right 2x6 Wall 2 (Right-270) - - 1 36.0 0.30 0.23 Insect Screen (default) Right Fixed 2 Window Right 2x6 Wall 2 (I11gW270) - - 1 13.3 0.26 0.25 Insect Screen (default) OPAQUE DOORS 01 02 03 04 Name Side of Building Area(ft2i U-factor Front Door Front 2x6 Wall 24.0 0.50 Front Garage Door Front Garage Wall 21.0 0,50 Car Do or FG Wali 128.0 0.50 Registration Number: 217_P010024971E-000-000-0000000-0000 Registration DaleTme: 2017.11.20 12:19:41 HERS Provider: CeICERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 08:47:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Griffin Ranch 2017 - Plan #5(4154) Calculation DateTme: 08:46, Mon, Nov 20, 2017 Page 7 of 12 Calculation Description: Title 24 Analysis Input File Name: Lenni396.ribd16x OVERHANGS AND FINS 01 02 OJ --04 Or-06 07 1 08 1 09 10 11 1 12 13 14 Overhang Left Fin - Right Fin Window ..:: Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up i Depth Top Up Dist R Sot Up Front Fixed 8 1 2 2 0 - 0 0 0 0 0 0 0 0 Front Fixed 2 12 _ 1 2 2 0 0 0 0 0 0 0 0 0 Front Folding Window 8 2.5 2 2 0 0 0 0 0 - 0 0 0 0 Front Stacking. Glass Door .. 12 1 2 2 0 0 0 0 0 .. 0 0 0 0 . .. Left Openable 12 2.5 2 2 .. 0. 0- 0 0 0 0 0 0 0 Left Fixed 12 1 2 2 0 0 0 0 0 0 0 0 0 Back Sliding Glass Door 1.5 2 2 - 2 0 0 0 0 0 0 0 0 0 Back Openable 1.5 2 2. 2 0 0 0 0 0 0 0 - 0 0 .. Right Openable - 12 2.5 .... 2 2 0 0 0 0 0 0 0 0 0 Right Fixed -. 12 1 2_ 2 0 0. 0 -D - 0 0 0 0 D Front Stacking Glass Door 2 12 1 t-2 Z* 2=' ° -`-i 0!f'�i, * o 0 0 D o 0 0 0- Back Fixed 1.5 S* 2 2� ,� } �2 k""'{0' 0 'to- 0 , ' 0 0 0 0 0 0 Back Fixed 2 1.5 °c ,:.N'0.3 * 2 4-f A '24 $-110'i L O*WO ;f 0� t 1A O�*+i S 0 0 .. 0 0 0 Back Oponatile 2 1.5 ''�r2 <.22 2 i (0 1- {, �0. °1 i ( 0' ;f F DIR 0 0 0 0 0 Back Openable 31 1.5 2 2 2 0 0 0 0 0 - 0 0 0 0 Back Openable 4 1.5 2 2 2 0 0 0- 0 0 0 0 0 0 Back Fixed 3 1.5 2 2 2 0 D 0 0 0 0 0 a 0 Registration Number: 217-Pp10024971E-000.000-W00000-000D Registration DateMme: 2017-11-2012:19:41 HERS Provider: CaICERTS Inc, CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 08:47:09 e CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Griffin Ranch 2017 - Plan tl5(4154) Calculation Datemme: 08:46. Mon, Nov 20, 2017 Page 8 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr396.ribdl6x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 D6 - 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers Ceilings (below Inside Finish: Gypsum Board R-0 Garage Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: noinsul. /20 Inside Finish: Gypsum Board • Cavify/Frame: noinsui. /2x4 R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.361 Exterior Finish: 3 Coat Stucco Cavity/Frame: no instil. /2x4 Top Chrd • Roof Deck: Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss 24 Tile Gap: present Attic Garage Roof Cons Attic Roofs Wood Framed Ceilnng, in. O.C. none 0.400 Roofing: 10 PSF (RoolTfe) Around Roof Joists: R-17.0 insul. • Cavity/Frame:R-13.0/2x4Top Chrd • Roof Deck Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap., present Attic RoofLlving Attic Roofs Wood Framed Ceiling in. O.C. R 30 0.040 Roofing: 10 PSF (RootTle) _ Ceilings (below Inside Finish: Gypsum Board R-30Attic HPA attic) ""'r" WoodFramedCerbnQ, "' ,�'� 2x4`((D'24i�.O.C,"`�r � none: „..„. .O,n81 Cavi y/Frame: no insul./2x4 Inside Finish: Gypsum Board Cavity/Frame: R-2f /2x6 R•21 Wall Exterior Walls yNod.Fr0m0d Wa0 _ ,2x6 @ 16.in.O.C. ' R 21.. , 0.069 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board • Cavity/Frame:R-15/2x4 R-15 Wall House/Garage Interior Walls Wood Framed Wall 2x4 @ 16 In, O.C. R 15 0,086 Other Side Finish: Gypsum Board _- Inside Finish: Gypsum Board Cavity/Frame: no Insul. /2x4 R-0 Walll Interior Walls Wood Framed Wall 2x4 @.16 in. O.C. none 0.277 Other Side Finish: Gypsum Board Around Roof Joists: R-1 Z0 insul. • Caviy/Frame: R-13.0/2x4 Top Chnf • Roof Deck: Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap., present. Attic RoofBedrooms Attic Roofs Wood Framed Ceiling in, O.C. R 30 0.040 Roofing: 10PSF(R6017111e) SLAB FLOORS 01 02 03 - 04 05 as 07 Name Zone Area (ft) Perimeter(D) Edge Insul. R-value 3 Depth Carpeted Fraction Heated Slab -on -Grade Living - 2204 92 None 0.8 No Slab -on -Grade 2 - Bedrooms 1950 160 None 0.8 No Garage Slab _Garage^ 678 81 None 0 No Registration Number 217-P01CO24971E-000-000-0000000-0000 Registration DatefTlme: 2017-11.2012:19AI HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Slandarda - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at. 2017-11-20 08:47:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #5(4154) Calculation DateTme: 08:46, Mon, Nov 20, 2017 Page 9 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennf396.ribdl6x BUILDING ENVELOPE- HERS VERIFICATION -- 01 02 03 .. ... 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required We WATER HEATING SYSTEMS 01 02 03 04 05 06 Name - System Type Distribution Type Water Heater Number.of Heaters- Solar Fraction (% ) DHW Sys 1 DHW Recirculation with demand control, push button DHW Heater 1 (1) 1 .0% WATER HEATERS 01 02 03 04 OS 06 07 08 -09 10 11 12 Name Heater Element Type Tank Type- Number of Units Tank Volume (gal) Uniform Energy Factor Energy Factor / Efficiency Input Rating Pilot Thermal Efficiency / Tank Insulation R-value (Int/Fxd) Standby Loss / Recovery EH First Hour Rating / Flow Rate NEEA Heat Pump Brand I Model Tank Location or Amblent Condition DHW Heater 1 Gas Consumer Instantaneous (UEF) 1 0 ,r ,rgca 092 UEF r ij , 1F 1"�e3 �99,900 Yv E .e•+ 0 wry, nfa,,«, 1Pt 10 GPM n/a n/a SPACE CONDITIONING SYSTEMS « r ««' -• r« r•: r-. r'«- -.. l•-• r•� SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC - Living I Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - Bedreoms2 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC - HEATING UNIT TYPES 01 _ 02 03 04 Name System Typo Number of Units Efficiency Heating Component 1 CntdFumace 1 92 AFUE Heating Component 2 CntdFumace 1 92 AFUE Registration Number. 217_P010024971E•000-00"000000.0000 Registration Dale/flme: 2017-11_2012:19:41 HERS Provider. CeICERTS inc, CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2017-11-20 08:47:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #5(4154) Calculation Date✓Tme: 08:46. Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennf396.ribdl6x C F1 R-PRF-01 Page 10 of 12 HVAC - COOLING UNIT TYPES 01 02 03 64 1 05 06 07 08 Name System Type Number of Units Efficlency EER SEER Zonally Controlled Compressor Type HERS Verification - Cooling Component 1 SplitAirCond 1 12 14 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 1 12 14 Zonally Controlled Single Speed Cooling Component 2-hers-cool HVAC COOLING - HERS VERIFICATION 01 - 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Vedfied SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Not Required Required Cooling Component 2-hers-cool -Required 275 Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 , "° 4c03e "-° v )x" t'"04r1 05 06 07 Name - Type r: aI ,Duct Le'akago off."61att R-valyp I Oct Location Bypass Duct - HERS Verification Air Distribution System 1 OL Isi; Mh 1 g,. S od6ed L4weY.I.oOknge' 1 t 7argatt r '` £ #' 6 a rti V " 14 %4u'' d Conditioned zone tMy {_ t.1 None Air Distribution System 1-hers-dist Air Distribution System 2 DuctslnAll Spedped Lower Leakago Target 6- Conditioned zone None Air Distribution System 2-hers-disl 2-her HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 O5 06 07 - 08 Name Duct Leakage Verification Duct Leakage Target I%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-d;st Required 5.0 Required Not Required Not Required Not Required Required Air Distribution System 2-hers-d1st - Required - - - 5.0 Required Not Required Not Required Not Required Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single -Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2-hers-fan Registration Number: 217-P010024971E-000-000-000000o-0a00 Registration Oats/Time: 2017-11-20 112;119;41 HERS Provider.. CaiCERTS Inc, CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 08:47:09 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Griffin Ranch 2017 - Plan #5(4154) Calculation DateMme: 06:46, Mon, Nov 20, 2017 Page 11 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr396.ribd16x HVAC FAN SYSTEMS - HERS VERIFICATION Ot 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (WattsrCFM) HVAC Fan 1-hers-fan Required - 0.58 HVAC Fan 2-hers-fan Required - 0.58 JAQ (Indoor Air Quality) FANS 01 02 03- 04 05 06 Dwelling Unit IAQ CFM IAQ Watt$1CFM IAQ Fan Type IAQ Recovery ENoctivcness1%) . HERS Verification SFam IAQVentRpl - 87 0.25 Default - 0 - Required t�j- e; 46 Ei'dcnn i ce a Registration Number 217•P010024971E-000-000-0000000-00D0 Registration DateMme: 2017-11-2012:19:41 HERS Provider WCERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SPt Report Generated at: 2017-11-20 08:47:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #5(4154) Calculation DateMme: 08:46, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr396.ribdl6x CFIR-PRF-01 Page 12 of 12 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complele. Documentation Author Name: Documentation Author Signature, Rick Maurer Company: - Rick Maurer Title 24, Inc. Signature Date: 2017-11-20 12:18:54 _ r ABF�^t—' Address: CEA/HERS Certification Identification (If"oppkabl r 7544 Saddiehiil Trail R13-90-10024 City/State/Zip: - - Phone:: Orange, CA 92669 714-771-1507 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design Identified on this Certificate of Compliance. 2, 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations, 3. The building design features or system design features Identified on this Certificate of Compliance are consistent with the Information provided on other applicable compliance documents, worksheets, calculations, plans and spoa8cpli6ns submlited to (he entrncamanl8_gency_for.a_ppfoval,WltA thlS tiflding"permit application. Responsible Designer Name: d sty �_. Responsible Designer Signature:#- �j ' �c�t%! James Jenike ft i .-+ F ." Gonlpp nY: '� �- i ( {' � ,' DatgSlgned: 1 . r 2017-11-20� 12:19:41 Lennar Homes - Southern CA Address: License: 980 Montecito Drive, Suite 302 City/State/Zip: Phone: Corona, CA 92879 951-817-3500 Digitally signed byCa10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 217-Pp10024971E-000-000.0000000.0000 Registration Date/Tme: 2017-11-20 12:19:41 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 'Rsr Easy to Verify at CaICERTS.com HERS Provider. CaICERTS im. Report Generated at: 2017-11-20 08:47:09 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - Plan #5(4154) Date 11/20/2017 System Name HVAC - Living Floor Area 2,204 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM_ . Total Room Loads 1,185 Return Vented Lighting Return Air Ducts Return Fan Ventilation F 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD. COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 80,000 25,010 -Z;9651 491 19,296 Total Output Btuh 80,000 0 Output Btuh/s ft 36.3 387 238 Cooling System 0 0 Output per System 60,000 0 01 0 0 Total Output Stuh 60,000 0 387 1 25,784 2,965 0 Total Output Tons 5.0 238 Total Output Btuhls 27.2 Total Output s Wron 440.8 19,771 Air System CFM perSystem 2,200 HVAC EQUIPMENT SELECTION Airflow cfm 2,200 Liv. HVAC Equipment Selection & Sizing by Others 39,817 10,953 80,000 80,000 Jan 1 AM Airflow cfmis ft 1.00 Airflow cfmlron 440.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 39,817 10,953 Outside Air cfmi ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 68 OF 105 IF Outside Air 0 cfm Supply Fan Heating Coil 2,200 cfm 68 OF 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112178 OF 75162 OF 75 / 62 OF 55 / 54 IF Outside Air _TE -� 0 cfm Supply Fan Cooling Coil 55 / 54 IF 2,200 cfm� 4T8% E ROOM M 75/62OF (( 75/62OF EnergyPro 7.2. by EnergySoff: User Number.• 1686 ID: .Page 15 of 16. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - Plan #5(4154) bate 11/20/2017 System Name HVAC - Bedrooms Floor Area 1,950 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,196 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Sensible Latent CFM Sensible -HeatingSystem Output perSystem 80,000 25,238 2,624 541 21,221 Total Out ut Btuh 80,000 0 Output Stuh/s ft 41.0 391 261 System 0 0 -Cooling. Output perS em 60,000 0 0 0 0 Total Ou tput. Btuh 60,000 0 391 26,020 27624 0 Total Output Tons 5.0 261 Total Output Btuh/s ft 30.8 Total Output s ftrron 390.0 21,744 Air System CFM perSystem 2.200 HVAC EQUIPMENT SELECTION Airflow cfm 2,200 Bed. HVAC Equipment Selection & Sizing by Others 39,927 10,798 80,000 80,000 I Jan 1 AM Airflow cfm/s ft 1.13 Airflow cfmrron 440.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1 39,927 10.798 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Hearin Peak 26 OF 68 OF 68 OF 105 IF Outside Air 0 cfm Supply Fan Heating Coil 2,200 cfm 68 OF 4 UT 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 75 / 62 IF 75162 IF 55 / 54 OF 101 A 0 0'. 0Outside Air; ,T_u 0 cfm Supply Fan Cooling Coil 55154 OF 2,200 cfm 47.6% ROOM11 75 / 62 of 75 / 62 OF EnergyPto.7.2 by EnergySoR User Number. • 1686 ID: Page 16 of 16 BUILDING ENERGY ANALYSIS REPORT PROJECT: Lennar Homes - Plan #6(4529) Griffin Ranch 2017 La Quinta, CA Project Designer: Lennar Homes 980 Montecito Drive, #302 Corona, CA 92879 951-817-3600 Report Prepared by: Rick Maurer Rick Maurer Title 24 7544 Saddlehill Trail Orange, CA 92869 714-771-1507 Job Number: Date: 11 /20/2017 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software —www.energysoft.com. TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 HVAC System Heating and Cooling Loads Summary 18 EnergyPro 7.2 by EnergySoft Job Number. ID: User Number. 1686 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #6(4529) Calculation Datemme: 09:18, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr423.ribdl6x CF1R-PRF-01 Page 1 of 15 GENERAL INFORMATION 01 Project Name' Griffin Ranch 2017 - Plan 46(4529) 02 Calculation Description Title 24 Analysis 03 Project Location Griffin Ranch 2017 04 City La Quinta 05 - Standards Version Compliance 2017 06 Zip Code - 07 compliance Manager Version BEMCmpMgr 2016.3.0 (934 SPt) 08 Climate Zone CL15 - 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 - Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area(ft2) 4529 15 Numberof Zones 3 16 Slab Area (ft2) 4529 17 Numberof Stories 2 18 Addition Cond. Floor Amalie) n/a 19 Natural Gas Available Yea 20 Addition Slab Area (ft2) nia 21 Glazing Percentage (%) 21.1% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 Tht¢ building incorporates features that rnquito field testing srldlotverifieatiorl,by a,e¢rUtled h1 RS talei,;urider Iiy,O 5uperv,* of a CEC -approved HERS provider. .... 01 -s., . _ . ., This building Incorporates one or more�Special Featiirlis`shown Registration Number. 2i7-PoloW2139"oo.oa0-0aoo00a-000o Registration DateMme: 2017-11-2012:19:42 HERS Provider. CaICERTS Inc CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2017-11-20 09:19:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Gruen Ranch 2017 - Plan #6(4529) Calculation DatelYme: 09:18, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr423.ribd16x CFIR-PRF-01 Page 2 of 15 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/R2-yr) Design Design Margin Improvement Space Heating 2.29 2.48 -0.19 -8.3% Space Cooling 83.99 67.22 16.77 20.0% IAQ Ventilation 0.84 0.84 0.00 0.0% Water Heating 3.14 2.94 0.20 6.4% PV Credit -. 0.00 0.00 - North Facing Compliance Total 90.26 73.48 16.79 18.6% Space Heating - 2.29 2.46 -0.17 -7.4% Space Cooling 83.99 74.17 9.82 11.7% IAQ Ventilation 0.84 0.84 0,00 0.0% Water Heating 3.14 2.94 0.20 6.4% PV Credit - 0.00 0.00 - East Facing Compliance Total 90.26 80.41 9.85 10.9 % Space Heating - Space Cooling 229. 33'.114 „,63,9, p r.1 i '" i±2y 1, , ,ems -0.85 14.10 -37.1% 18.6% IAQ Ventilation 084it a C�{ 0.8.4 ,94 A 0.00 0.0% Water Heating 4.pp`t- z.y4 0.20 6.4% PV Credit �-, H F-- I {'" ; `. `,.i 6;06 f [[ ;,) t : t'? 0.D0 - South Facing Compliance Total 90.26 76.01 13.45 14.9% Space Heating 2.29 2.96 -0.67 -29.3% Space Cooling 83.99 69.14 14.85 17.T% IAQ Ventilation 0.84 0.84 0.00 0.0% Water Heating 3.14 2.94 0.20 6.4% PV Credit - 0.00 0.00 - West Facing Compliance Total 90.26 75.88 14.38 15.9% Registration Number. 217-P0100i32139D-000.000-0000000-0000 Registration Data/lime: 2017-11-20 12:19:42 HERS Provider. CsICERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compflence Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 09:19:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Grim Ranch 2017 - Plan #6(4529) Calculation DatelTme: 09:18, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr423.ribdl6x CF1 R-PRF-01 Page 3 of 15 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energyperformance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" Its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), It Is not used to show compliance with Part 6 but may Instead be used by local jurisdictions pursuing local ordinances under Title 24, Pan 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards Is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of Installed PV so that the effects of efficiency and renewable energy can both be soon EDR of Standard Efficiency EDR of Proposed Efficiency .. EDR Value of Proposed PV + Battery Final Proposed EDR North 62.0 44.3 0.0 44.3 East 52.0 - 47.5 0.0 47.5 -. South 52.0 46.9 0.0 - - 45.9 West 52.0 45.4 0.0 45A ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin(CALGraen A4.203.1.2.1) and Qll verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and Oil verificationPrerequisite. ❑ Design meets Zero Net Energy JZNE) Design Designation requirement for Single Familyin climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) Including on -silo photovoltaic (PV) renewable energy generation sufficient to aclileve a Final Energy DesigtnF Rating (EDR) of zero or less. The PV System must be verified. Notes: „s. + `?.1+•� ... Excess PV Generation EDR Credit: Bypassing PV siio ltmit.ma viotato Net F Meterin I�Eh1 rulesi 4 REQUIRED SPECIAL FEATURES •V" Tho following are features that must be installed as condition for mee{mg the modeled energy performAcr kf thls beiiiiputef wl AlS,'" • Non-standard roof reflectance • Window overhangs and/or fins • Nonstandard duct location (any location other than attic) • Recirculation with demand control, push button Registration Number: 217-Po10002139D-000-o0D-0000000-0000 Registration DateMme: 2017-11-20 12:19:42 HERS Provider: CatCERTS Inc; CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-09012017-934 SPt Report Generated at: 2017-11-2009:19:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #6(4529) Calculation DatefTime: 09.18, Mon, Nov 20, 2017 Page 4 of 15 Calculation Description: Title 24 Analysis Input File Name: Lennr423.dbdl6x HERS FEATURE SUMMARY The following Is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis, Additional detail Is provided In the building components tables below. Building -level Verifications: • High quality insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum AlAlow • Verified EER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Ducts located entirely in conditioned space confirmed by duct leakage testing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: --None — BUILDING - FEATURES INFORMATION 01 02 03 04 06 - as 07 iNumber otDwelling' r'•`=`=';:'—'""'�'yR" Number of Ventilation NumberofWater Project Name Conditioned Floor Area (ft2)' ''Units c Number of Bedrooms, Numboromltt1 Cooling Systems Heating Systems Griffin Ranch 2017 - Plan #6(4529) 4529 ,,, �3, __ Al )C »,,,,, ,:, R. q � x .3„t 3r 1ietx''" a, 0 1 ZONEINFORMA71ON 01 - 02 03 04 06 06 07 Zone Floor Area - Avg, Ceiling Zone Name Zone Type HVAC System Name (R=) Height Water Heating System 1 Water Heating System 2 Living Conditioned HVAC - Livingl 2205 12 DHW Sys 1 n/a Castle Conditioned HVAC - Casi1a2 357 10 DHW Sys 1 n/a Bedrooms Conditioned HVAC -Bedrooms3 1967 12 --DHW Sys 1 n/a Registration Number: 217-PO1 doo22199D-000-000-0000009-0000 Registration Dalerrime: 2017_11_20 12:19:42 HERS Provider. CaICERTS Inc, CA Building Energy Efficiency Stardards -2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2017-11-20 09:19:21 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name- Griffin Ranch 2017 - Plan #6(4529) Calculation DatoMme: 09:18, Mon, Nov 20. 2017 Page 6 of 1s Calculation Description: Tile 24 Analysis Input File Name: Lennr423.ribd 1 6x OPAQUE SURFACES _ 01 .. 02.... 03 04 06 06 07 - 08 Name Zone Construction Azimuth Orientation Gross Area (10). Window 6 Door Area (R J Tllt (dog) Front24 Wall Living R-21 Wall 0 Front 240 52 90 Left 2x6 Wall-Liv1n4 R-21 Wall 90 Left 230 - - 48 90 Back 2x6 Wall Living R-21 Wall - -'180 Back 660 392 90 Right 2x6 Wall Living R-21 Wall 270 Right 252 15 90 Front 2x6 Garage Wall tivhig>'_Garage_ R-21 Wall House/Garage n/a n/a 100 21 n/a Right 2x6 Garage Wall Uving»_Garaga_ R-21 Wall House/Garage n/a n/a 50 0 n/a Interior Surface Living»Casita R-0 Wall We rda 50 0 n1a Interior Surface 2 Living»Bedrooms R-0Wallt nla We 700 0 n/a Gelling Below Attic Living R-30 Attic HPA - n/a We 2205 n/a We Front 2x6 Wall 2 Casita .. R-21 Wall 0 Front 240 30 90 Lett 2x6 Wall 2 Casita R-21 Wall 90 Left 140 8 90 Back 2x6 Wall 2 - Casita _ R-21 Wall 180 Back 240 64 - 90 Right 2x6 Wall 2 Casita J` ..+ R-211Nai1 g. 270 `zj aWgNt ,s. 140 0 90 Ceiling Below Attic 2 Front 2x6 Wall 3 ;Casita- - J Bedro0ais6 ' 1 %-90 Alge HPXi ' __ R-21 Wall _ nq .0- r gn/a) a Front 357 300 We 56.3 n/a 90 Left 2x6 Wall 3 Bedrooms°•. ti 8 •� ti �' W21 Wal( ' ' 96 ! , 'LOft 1 814. 129.5 90 Back 2x6 Wall 3 - Bedrooms - R-21 Wall 180 Back 444 132 90 Right 2x6 Wail 3 Bedrooms R-21 Wall 270 Rlghl 550 - 64.5 - - 90 Front 2x6Garage Wall 2 Bedrooms —_Garages R-21 Wall House/Garage We n/a 320 0 nla Right 2x6 Garage Wall 2 Bedrooms»Garage_ R-21 Wag HouselGarage n/a n/a 160 0 nta Ceiling Below Attic 3 Bedrooms R-30 Attic HPA We n/a 1967 n/a We FG Wall _Garage_ R-0 Wall 0 Front 420 144 90 LG Wall _Garage_ R-0 Wall 90 Left 110 0 - 90 RG Wall _Gwage_ R-0 Wall 270 Right 220 - - 72 90 RG Wall 2 ._garage_ R-0 Wall 270 Right 100 0 90 Garage Ceiling Garage_ I R-0 Garage Attic Hies We 716 We Hies Registration Number. 217-P010002139D-000-000-0000000-0000 Registration DateRme: 2017-11-20 12:19:42 HERS Provider CaICERT51rx. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-09012017-934 SP1 Report Generated at 2017-11-20 09:19:21 0 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #6(4529) Calculation Dateffime: 09:18, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr423.ribdl6x CF1 R-PRF-01 Page 6 of 16 ATTIC 01 02 03 -04 05 06 07 08 Name Construction - Type Roof Rise Roof Reflectance Roof Emlttance Radiant Barrier Cool Roof Attic Living Attic Rookiving - Unventilated 3 0.16 0.89 No No Attic Casita Attic Ro&Caslta Unventilated 3 0.16 0.89 No No Attic Bedrooms Attic RoolBedrooms Unventilated 3 0.16 0.89 No No Attic Garage_ Attic Garage Roof Cons Ventilated 3 0.16 0.89 No No Registration Number 217-P010002139D-000�000-0000000-0000 Registration Date/nme: 2017-11-20 12:19A2 HERS Provider CoICERTS tic. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 09:19:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #6(4529) Calculation DateTme: 09:18, Man, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr423-ribdl6x CFI R-PRF-01 Page 7 of 15 FENESTRATION 1 GLAZING _ 01 02 03--- 04 05 06 07 OB 09 10 Name _ Type Surface(Orientation-Azimuth) - Width(ft) Height (ft) Multiplier Area (ft2) Udactor SHGC Exterior Shading Front Fixed - Window - Front 2x6 Wail (Front-0) 4.0 6.0 1 24.0 0.26 0.25 Insect Screen (default) Left Operable Window Left 2x6 Wall (Left-90) - 1 8.0 0.30 0.23 Insect Screen (default) Left Hinged. Glass Door Window Left 2x6 Wall (Left-90) 5.0 8.0 - -1 _ 40.0 0.3D 0.23 Insect Screen (default) Back Fixed Window Back 2x6 Wall (Back-180) 16.0 1.5 1 24.0 0.28 0.25 Insect Screen (default) Back Stacking Glass Door Window Back 2x6 Wall (Bark-180) 16.0 8.0 1 128.0 0.32 0.20 Insect Screen (default) Back Stacking Glass Door 2 Window Bark 2x6 Wall (Back-180) 24.0 10.0 1 240.0 0.32 0.20 Insect Screen (default) Right Operable . Window Rigsµ 2x6 Wall (Right-270) - - 1 15.0 0.30 0.23 Insect Screen (default) Front Operable Window Front 2x6 Wall 2 (Front-0) 5.0 6.0 1 30.0 0.30 0.23 Insect Screen (default) Left Operable 2 Window Left 2x6 Wall 2 (Left-90) - 1 8.0 0,30 0.23 Insect Screen (default) Back Operable Window Back 2x6 Wail (Beck-180) �4.0 6.0 - 1 24.0 0.30 0.23 Insect Screen (default) Back Hinged Glass Doer Window Back 2xS Wall 2 (Back-180) 5.0 8.0 1 40.0 0.30 0.23 Insect Screen (default) Front Fixed 2 Window Fton(`ZiG. Wall 3'(Ftont-0) "'''") e =4 °"; "" ^ 1 8.3 0.26 0.25 Insect Screen (dofaull) Front Hinged Glass Door - Window CL Front 24Vvali 3' Front-0) ,`""' '"+yt 6,0yi -*(,8.0 St Q( 49.0 0.30 - -023 Insect Screen (default) Left Operable 3 Window, `^ t$R 2i 5 Wag 3 (Lefh90)" " " q 7.0 ' A 8 0 °iki ar wil2A 0.30 0.23 Insect Screen (default) Left Fixed Window Lef♦2)0 Wan.3.(L6jt t.5 _. tp^ - -{10.5 0.26 0.25 Insect Screen (default) Left Operable 4 Window Left 2x6 Wall, 3 (Lett-90) 5.0� 5.0 1 25.0 0.30 0.23 Insect Screen (default) Left Operable 5. Window Left 2x6 Wall 3 (Left-90) 2.0 4.0 1 8.0 0.30 0.23 Insect Screen (default) Left Operable 6 Window Left 2x6 Wall 3 (Left-90) 6.0 6.0 1 36.0 0.30 0.23 Insect Screen (default) Left Operable 7 Window Left 2x6 Wall 3,(Left-50) 2.0 4.0 1 8.0 0.30 0.23 Insect Screen (default). Back Fixed 2 Window Back 2x6 Wail 3 (Back-180) 6.0 1.5 -1 9.0 0.26 0.25 Insect Screen (default) Back Hinged Glass Door 2 - Window Back 2x6 Wall 3 (Back-180) 6.0 8.0 1 48.0 - 0.30 0.23 Insect Screen (default) Back Fixed 3 . Window Back 2x6 Wall 3 (Back-180), 10.0 1.5 1 15.0 0.26 0.25 Insect Screen (default) Back Fixed 4 Window Back 2x6 Wall 3 (Back-180) 6.6 6.0 1 36.0 0.26 0.26 Insect Screen (default) Back Openabie 2 Window Back 2x6 Wall 3 (Back-180) 4.0 6.0 1 24.0 0.30 0.23 Insect Screen (default) Right Openable 2 Window Right 2x6 Wall 3 (Right-270) - 1 36.0 -0.36 0.23 Insect Screen (default) Right Fixed Window Right 2x6 Wall 3 (Right-270) 3.0 1.5 1 4.5 0.26 0.25 Insect Screen (default) Right Hinged Glass Door Window - Right 2x6 Wall 3 (Right-270) 3.0 8.0 1 24.0 0.30 0.23 Insect Screen (default) Registration Number: 217-POf0002139D-000.00DMO0000-0000 Registration DateTme: 2017-11-20 12:M,42 HERS Provider. CeICERTs Inc. CA Building Energy Efficiency Standards- 2016 Residential Compliance Report Version - CF1 R-09012017-934 SPt Report Generated at:2017-11-20 09:19:21 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan 46(4529) Calculation DateMme: 09:18, Mon, Nov 20. 2017 Page 8 of 16 Calculation Description: Title 24 Analysis Input File Name: Lennr423.ribdl6x OPAQUE DOORS Name Side of Building Area (fe) U-factor Front Door Front 2x6 Wall 28.0 0.50 Front Garage Door Front 2x6 Garage Wag 21.0 0.50 Car Door FG Wall 144.0 0.60 Car Door 2 RG Wail 72.0 0.50 .06 S C E 'Fe"' cswx xa n' o I.". �..... �.j Registration Number 217-P010002139D-000-000-0000000-0000 Registration Daterfime: 2017-11-20 12:19*42 HERS Provider: CeICERTS Inc, CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 09:19:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name' Griffin Ranch 2017 - Plan #6(4529) Calculation DateMme: 09:18, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr423.ribdl6x CF1R-PRF-01 Page 9 of 16 OVERHANGS AND FINS 01 02 03 1 04 1 05 06 07 OB 109 1 10 11 1 12 1 - 13 1 14 .. _.- Overhang Left Fin Right Fin _. ... -_. Window Depth Dist Up Left Extent Right Extent Flap Ht. .:. Depth. Top Up, Dist L ,. Bot Up Depth Top Up Dist R Bot Up Front Fixed 2 2 2 2 .. 0 0 0 0 0 - 0 0 0 0 Left Hinged Glass Door 1.5 4 2 2 0 0 0 0 0 0 0 0 0 Back Fixed 10 0.5 2 2 0 0 0 0 0 0 0 - 0 .. 0.. Back Stacking Glass Door 10 3 2 2 0 0 0 0 0 0.. 0 0 0 Back Stacking Glass Door 2 14 0.5 2 2 0 0 0 0 0 0 0 0 0 Front Operable 1.5 0 2 2 0 0 0 0 0 0 0 0 0 Back Openable 1.5 3 2. 2 0 0 0 0 0 0 0 0 0 Back Hinged Glass Door 1.5 3 2. 2- _ 0 0 0 0 0 0 0 0 0 Front Hinged Glass Door 6.5 2 2 2 0 0 0 0 0 0 0 0 0 Left Openable 3- - 1.5 4 2 2 0 0 0 0. 0 - 0 _..0.. 0 0 Left Fixed 1.5 1.5 ,t 2; 2;"". 0: wo eAk of 0 0 0 0 0 0 Left Openable 4 1.5 �, 2 2-_4 1. ft - r O-L q 4 0 '�, OP 4 10'- 0 0 0 0 0 Left Openable5 1.5 S ;;s„_ 1.5 kiir2?: 0 2maa is-*a0't } B 0*aao 0X 1 11 o'%,a # 0 0 0 0 0 Left Openable 6 6 -ZA-15. Ir 2 tl r':2 °- , : 0 �^ i("0 4i i 0 ) I- 0p 0 0 0 0 _0- Left Openable 7 6 1.5 2 2 0 0 0 0 0 0 ,0 0 0 Back Fixed 2 14 0.5 2 2 0 0 0 0 0 0 0- 0 0 Back Hinged Glass Door 2 14 0.5 2 2 0 0 0 0 0 0 0 0 0 Back Fixed 3 7 0.5 2 2 0 0 0 0 0 0 0 0 0 Back Fixed 4 7 ..... 3 2 - 2 0 0 0 0 0 0 0 0 0 Back Operable 2 - 7 3 2 2 0 0 0 0 0 0 - ..0.. 0 0 Right Fixed 14 1.5 2 2 0 0 0 0 0- 0 0 - 0 0 Right Hinged Glass Door 14 0.5 2 2 0 0 0 _ 0 0 0 0 0 0 Registration Number: 217-PO10002139D-Ooa-ooO-Obb0000-0000 Registration Datelllme: 2017-11-20 12:19:42 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-0901 2017-934 SP1 Report Generated at 2017-11-20 09:19:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #6(4529) Calculation DateMme: 09:1 B, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr423.ribd16x CFI R-PRF-01 Page 10 of 15 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 0S 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor AssemblyLayers Ceilings (below - - Inside Finish: Gypsum Board R-0 Garage Attic attic) Wood Framed Ceiling 2x4 @.24 in. O.C, none 0.461 Cavity/Frame: noinsul: /2x4 • Inside Finish: Gypsum Board • Cavity/Frame. noinsul./2x4 R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C, none 0.361 Exterior Finish: 3 Coal Stucco Cavity/Frame: noinsul,/2x4 Top Chrd • Roof Dock., Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 rile Gap: present Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.400 Roofing., 10 PSF(RoolMo) Around Roof Joists: R-17.01nsul, • Cavity/Frame: R-13.0I2x4 Top Chrd • Roof Deck. Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic RoofLiving Attic Roofs Wood Framed Ceiling in. O.C. R 30 0.040 Roofing: 10 PSF (Rooirte) Ceilings (below _ Inside Finish: Gypsum Board R-30 Attic HPA attic) Wood Framed -Ceiling,'• 2zd @ 24 In OC ,' ; nono� a - 0.!I61 • �Cav1N/Promo; no insul. /2x4 V""' t1st th3; • titf ` Inside Finish: Gypsum Board Cavity/Frame: R-21/Zx6 R-21 Wall Exterior Walls 'Wood Framed Wa0 — 2x6 @ 16 in. O.C. , ' R Z'j SS *w : _ ,.0.069 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board - Cavity/Frame: R-21/2x6 R-21 Wall House/Garage Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.064 Other Side Finish: Gypsum Board Inside Finish: Gypsum Board • Cavity/Frame: noinsul./2x4 R-0 Walit Interior Wails Wood Framed Wall 2x4 @. 16 in. O.C. none 0.277 Other Side Finish: Gypsum Board _ • Around Roof Joists: R-1 7.0 Insut • Cavity/Frame:R-13,0/2x4Top Chni • Roof Deck., Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic RoofCasita Attie Roofs Wood Framed Ceiling in. O.C. R 30 0.040 Roofing: 10 PSF (Roofiile) • Around Roof Joists: R-17.0 insul. • Cavity/Frame:R-13.0/2x4Top Chrd • Roof Deck: Wood Siding/shealhing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic RoofBedrooms Attic Roofs Wood Framed Ceiling in. O.C. R 30 0.040 Roofing: 10 PSF (Reoor/e) Registration Number: Registration DaleMme: 2017-11.20 12:19:42 HERS Provider. CaiCERTS Inc. 9 217-P0100021390-000-000-0000000-0000 CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at:2017.11-20 09:19:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #6(4529) Calculation DateMme: 09:18, Mon, Nov 20, 2017 Calculation Description: Tile 24 Analysis Input File Name: Lennr423.dbdl6x CF1 R-PRF-01 Page 11 of 15 SLAB FLOORS -01 02 03 04 06 - 06 07 Name Zone Area (tt) Perimeter (it) Edge Insul. R-value 8 Depth Carpeted Fraction Heated Slab -on -Grade Living 2205 119 None 0.8 No Slab -on -Grade 2 Castle 357 76 - None - 0.8 No Slab -on -Grade 3 Bedrooms - - . 1967 t96 None 0.8 No Garage Slab _Garage_ 716 85 None 0 No BUILDING ENVELOPE- HERS VERIFICATION 07 .. - 02 03 04 Quality Insulation Installation (Qlq Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required _ n/a WATER HEATING SYSTEMS 01 02 07 04 - - 05 06 Name System Type - Distribution Type Water Heater Number of Heaters: Solar Fraction (%) DHW Sys 1 F'—' OHW Redicul ii' 'h d`ema tl cCrifrrit; • 1 Push,Cutton r 11 - yr DHW Neater 1 (1) .•; x• �A 1 .0% WATER HEATERS -.t <........_,- r. •..x- ..�...... n .,... (,,. _ .. _ .,_., .. 01 02 03 0"4`. IOS' _ .: ) � 067 C ' I"�p7l..r' ' �` OB -.- • . 09 + 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor I Energy Factor I Efficiency Input Rating Pilot I Thermal Efficiency I Tank Insulation R-value (Int/Ext) Standby Loss I Recovery Eff First Hour Rating Flow Rate NEEAHeat Pump Brand i Model Tank Location orAmblent Condition DHW Heater 1 Gas Consumer Instantaneous (UEF) 1 0 0.92 UEF 199,900 Stuthr 0 nla 10 GPM nla n/a SPACE CONDITIONING SYSTEMS 01 _ .. 02 03 04 _ .. _ 05 06 SC Sys Name System Type... Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC - Llvingl Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - Casita2 Heal Pump Heating and Cooling System Heat Pump System 2 Heat Pump System 2 HVAC Fan 2 Air Distribution System 2 HVAC - Bedrooms3 Other Healing and Cooling - System Heating Component 3 Goofing Component 3 HVAC Fan 3 Air Distribution System 3 Registration Number: 217-POt00D2139D-000•000.000000"000 Registration Date/Time: 2017-11-20 12:19:42 HERS Provider: CaICERTS mc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-09012017-934 SP7 Report Generated at: 2017-11-20 09A9:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #6(4529) Calculation Datemme: 09:18, Mon, Nov 20, 2017 Page 12 of 15 Calculation Description: Title 24 Analysis Input File Name: Lennr423.ribd16x HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type - Number of Units Efficiency Heating Component 1 CntHFumace 1 92 AFUE Healing Component 3 CntdFumace 1 - 92 AFUE HVAC - HEAT PUMPS 01 02 - ....03 04 05 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPFICOP Cap 47 Cap 17 SEER EER Heat Pump System 2 SplitHeatPump 1 8.2 18000 12600 14 11 Not Zonal Single Speed Heat Pump System 2-hers-cool 14VAC - COOLING UNIT TYPES 01 02 03 04 06 06 07 08 Name 1 System Type ,�,, - Number of,UnIJA j, Efficiency EER, ,Q ,SEER„ Zonally Controlled Compressor Type HERS Verification CoolingCompanentl SpfitAlrCond t� Y ; Tfi�1 qi r tt F I. 12�1' 5 V,,, 14`L1 �'. 6 ¢scn,� .p�� Not Zonal• x rit Single Speed Cooling Component 1-hers-cool Cooling Component 3 Sp!itAirCond; f, e !^ I•', <. �,/ 1 Z Ily Cantrollod E i J 1` t"•. Single Speed Cooling Component 3-hers-cool HVAC COOLING - HERS VERIFICATION. 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cocl Required 350 Required - Not Required Required Cooling Component 3-hers-cocl Required 275 Required Not Required Required Heal Pump System 2-hers-cool Required 350 Not Required Not Required Required Registration Number 217-P010002139D-00b000-0000000-0000 Registration DateMme: 2017-11_20 12:19:42 HERS Provider. CaICERTS Inc, CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Repnrt Generated at: 2017-11-20 09:19:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #6(4529) Calculation Daterrime: 09:10, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr423.ribd16x CF1R-PRF-01 Page 13 of 15 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 - 06 .06. 07 Name Type Duct Leakage Insulation R-value Dud Location Bypass Duct HERS Verification Air Distribution System 1 DuctslnAll - Specified Lower Leakage Target - 6 Conditioned zone None Air Distribution System 1-hers-list Air Distribution System 2 DUdslnAll Sealed and tested 6 Conditioned zone None Air Dis her System 2-hers-dlsl Air Distribution System 3 DuctslnAll Specified Lower Leakage Target 6 Conditioned zone None Air Distribution System 3-hersdst HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Dud Leakage Target (%) Verified Duct Location Verified Duct Design Burled Ducts Deeply Buried Ducts Lowdeakage Air Handler Air Distribution System 1-hers-dist Required 5.0 Required Not Required Not Required Not Required Required Air Distribution System 2-hers-disl Required 5.0 Required Not Required Not Required Not Required n/a Air Distribution System 3-hers-disc Required - ,5,CL-, „ Repuire4 ; ,No1:Roqutmd Not Required Not Required Required HVAC - FAN SYSTEMS. 01 �r.,.e a:,.a hsw rU2"esa'ax*+" " 7. t' '"'c� t V 63 04 . Name ``iy ^-i ;^ Type j. i-^ -�, �44' 1FaA Powe`f0a)ts1CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan-1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan - - 0,58 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0,58 HVAC Fan 3-hers-tan HVAC FAN SYSTEMS - HERS VERIFICATION. .. 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 HVAC Fan 2-hers-fan Required 0.58 HVAC Fan 3-hers-fan Required 0.58 Registration Number. 217-P010002139D-000-000-0000000-0000 Registration Daterl'ime: 2017-11-2012:19:42 HERS Provider CaICERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SPI Report Generated at: 2017-11-20 09:19:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Griffin Ranch, 2017 - Plan #6(4529) Calculation Date/Time: 09:18, Mon, Nov 20, 2017 Page 14 of 15 Calculation Description: Title 24 Analysis Input File Name: Lennr423.ribdl6x IAQ (Indoor Air Quality) FANS 01 .. 02 03 04 05. 06 . _ Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 83 0.25 Default 0 Required C Registration Number: 217-P010002139D400-000400000040o Registration DataMme: 2017-11-20 12:19:42 HERS Provider. CaICERTS Inc. CA Building Energy Etticlency Standards -2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 09:19:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Gruen Ranch 2017 - Plan #6(4529) Calculation Date/Time: 09:18, Mon, Nov 20, 2017 Page 15 of 15 Calculation Description: Title 24 Analysis Input File Name: Lennr423.ribd16x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1..1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signatum, Rick MaurerQ� Company: Signature Date: Rick Maurer Title 24, Inc. 2017-11-20 12:18:54 CABS Address: CEA/HERS Certification Identification (IfapplIcabi v(^ Ufey,YsA:+..Mee.rJi il.� ts. euYa.0 7544 Saddlehill Trail R13-90-10024 City/State/Zip: Phone: - Orange, CA 92869 714-771-1507 RESPONSIBLE PERSON'S DECLARATION STATEMENT 1 certify the following under penalty of perjury, under the laws of the State of California: - 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design Identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications Identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistentwith the Information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to.the onfbrcetngnf;agency_(o1'approval yyiIft#41 Buliding'parmd application. Responsible Designer Name: f+ P`r >x ii, ff,,..,r,, Raspatt'ble Nsignor5rgrjalWe't James Jenikew ems: i .e . •� kilt Company: s<'� , Dale Signed. Lennar Homes - Southern CA 2017-1.1 20 12:19:42 Address: ._ _ - -. License: 98D Montecito Drive, Suite 302 City/State/Zip: Phone;' Corona, CA 92879 951-817-3500 Digitally signed byCaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration i Provider responsibifity for the accuracy of the information. Easy to Verify at CaiCERTS.com Registration Number.' 217-Pot0002139D-000-000-00D0000-0000 Registration Date/Time: 2017-11-20 12:19:42 HERS Provider CarCERTS Iec. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CFI R-09012017-934 SPi Report Generated at: 2017-11-20 09:19:21 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - Plan #6(4529) Date 11/20/2017 System Name HVAC - Living Floor Area 2,205 ENGINEERING CHECKS SYSTEM LOAD Number of S stems 1 COIL CFM Total Room Loads 1,345 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK System Sensible Latent CFM Sensible -Heating Output per System 80,000 28.267 3,606 582 22.837 Total Output Btuh 80,000 0 output Btuh/s ft 36.3 591 334 System 0 0 -Cooling Output per System 60,000 0 0 0 0 Total Output Btuh 60,000 0 1 591 1 29,449 3.606 0 Total Output Tons 5.0 334 Total Ou uY Stuh/s 27.2 Total Output s ftlTon 441.0 23,504' Air System CFM per System 2,200 HVAC EQUIPMENT SELECTION Airflow cfm 2,200 Liv. HVAC Equipment Selection & Sizing by Others 39,751 11,122 80,000 Airflow cfm/s ft 1.00 Airflow cfm/Ton 440.0 Outside Air "�6 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 39,751 11,122 80,000 Jan 1 AM Outside Air cfmis ft 0.00 Note: values above given,at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of -Heating Peak 26 OF 68 OF 68 OF 105 OF Outside Air 0 cfm Supply Fan Heating Coil 2,200 cfm 68 OF 105 OF ROOM MIM 68 IF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112 / 78 °F 75 ! 62 IF 75162 OF 55 / 54 OF r Outside Air-y��--� 0 cfm Supply Fan Cooling Coil 2,200 cfm 75162 OF 55 / 54 OF �- 48.1% ROOM -m 75 ! 62 IF EnergyPro 7.2 by EnergySoft User Number: 1686 ID: Page 18 of 20 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - Plan #6(4529) Date 11/20/2017 System Name HVAC - Casita Floor Area M7 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 277 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK System Sensible Latent CFM Sensible -Heating Output perSystem 18,000 5,861 584 247 7,069 Total Output Btuh 18,000 0 Output Btuhit ft 50.4 123 94 Cooling System 0 0 Output per System 18,000 0 0 0 0 Total Output Btuh 18,000 0 584 0 Total Output Tons 1.5 123 94 Total Output Btuh/s ft 50.4 Total Out ut t ftrron 238.0 1 6,106 7.257 Airs stem CFM perSystem 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Casita HVAC Equipment Selection & Sizing by Othe 11,413 3.' 63 11,242 Airflow cfm/s ft 2.24 Airflow cfm/Ton 533.3 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1 11,413 3,763 11,242 F Jan 1 AM Outside Air cfmis ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 68 OF 95 °F Outside Air 0 cfm Supply Fan Heating Coil 800 cfm 68 OF 95 of ROOM IN 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF 75/62°F 75/62°F 55/54°F ► f �► Outside Air �- 0 cfm Supply Fan Cooling Coil 800 cfm 75 / 62 OF 4 A.-E-ECU 14 1 - E`._ �r 55 / 54 IF 47.0% ROOM )l 75 ! 62 IF EnefgyPro 7.2 by EnergySoff User Number.- 1686 ID: Page 19 of 20 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - Plan #6(4529) Date 11/20/2017 System Name HVAC - Bedrooms Floor Area 1,967 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,337 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK System Sensible Latent CFM Sensible -Heating Output perSystem 80,000 28,093 3,217 641 25,136 Total Output Btuh 80,000 0 Output Btuh/s ft 40.7 587 367 System 0 0 -Cooling Output parSystem 60,000 0 0 0 0 Total Output (Bt6hi 60,000 0 587 1 29,268 3,217 0 Total Output Tons 5.0 367 Total Output Btuhls ft 30.5 Total Output s ftfTon 393.4 25,870 Air System CFM perSystem 2,200 HVAC EQUIPMENT SELECTION Airflow cfm 2,200 Bed. HVAC Equipment Selection & Sizing by Others 39,871 10,950 80,000 80,000 Jan 1 AM Airflow cfm/s ft 1.12 Airflow cfm/Ton 440.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 39,871 10.950 Outside Air cfm/s ft 0.00 Note: values abovegiven at ARI conditions I Aug 3 PM HEATING SYSTEM RSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 68 OF 105 OF Outside Air 0 cfm Supply Fan Heating Coil 2,200 cfm 68 OF 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112 / 78 °F 75162 °F 75162 OF 55154 OF Outside Air HTE 0 cfm Supply Fan Cooling Coil 2,200 cfm 75 / 62 OF IAD- U, +---� 55 / 54 OF 47.9% � ROOM 75162 OF EnergyPro 7.2 by Energy5o(t User Number. 1686 ID: Page 20 of 20 BUILDING ENERGY ANALYSIS REPORT PROJECT: Lennar Homes - Plan #7(4700) Griffin Ranch 2017 La Quinta, CA Project Designer: Lennar Homes 980 Montecito Drive, #302 Corona, CA 92879 951-817-3600 Report Prepared by: Rick Maurer Rick Maurer Title 24 7544 Saddlehill Trail Orange, CA 92869 714-771-1507 Job Number: Date: 11 /20/2017 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and Is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software —www.energysoft.com. TABLE OF Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 HVAC System Heating and Cooling Loads Summary 15 EnergyPro 7.2 by EnergySa4 dob'Number ID: User Number. 1686 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #7(4700) Calculation'DateTme: 09:30, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr397.ribd16x CF1R-PRF-01 Page 1 of 12 GENERAL INFORMATION 01 Project Name Griffin Ranch 2017 - Plan #7(4700) 02 Calculation Description Title 24 Analysis 03 Project Location Griffin Ranch 2017 04 City La Ouinta 05 Standards Version Compliance 2017 -- OS Zip Code 07.. _ .. Compliance Manager Version BEMCmpMgr 2016.3.0 (934 SP1) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Typo Single Family 11 Front Orientation {deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 , Total Cond. Floor Area.(ft2) 4706 15 Number of Zones 2 18 Slab Area(ft2) 47DO 17 Number of Stories 1 _. 18 Addition Cond. FloorArea(ftF) n/a 19 Natural Gas Available- yog 20 Addition Slab Area (ft2) n/a 21 Glazing Percentage (%) 18.4% COMPLIANCE RESULTS - 01 Building Complies with Computer Performance_{- 02 This building Incorporates features that require field testing andloi,verificaliori by a oertirred HERS rite under the ppoi f* of a CEC-approved HERS provider, 03 This building incorporates one orir rQ'SocialFealuresstiownbelow'"' Registration Number 217-POI0024973D-000-Odo-0doo000.0000 Registration Dalefrime: 2017-11-20 12:19:44 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFI R-09012017-934 SP1 HERS Provider. CeICERTS Inc. Report Generated at: 2017-11-20 09:30:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Griffin Ranch 2017 - Plan #7(4700) Calculation DateMme: 09:30, Mon, Nov 20, 2017 Page 2 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr397.ribdl6x ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDVI(I1-yr) Design Design Margin Improvement Space Heating 1.98 2.28 -0.30 - -15.2% Space Cooling 79.79 63.93 15.86 19.9% IAQ Ventilation 0.83 0.83 0.00 0.0% Water Heating 3.03 2.83 0.20 6.6% PV Credit - 0.00 0.00 - North Facing Compliance Total 85.63 69.87 15.76 18.4% Space Heating 1.98 1.82 - 0.16 8.1% Space Cooling 79.79 65.07 14.72 18.4% IAQ Ventilation 0.83 0.83 0.00 0.0% Water Heating 3.03 2.B3 0.20 6.6% PV Credit - 0.00 0.00 - East Facing Compliance Total 85.63 70.65 15.08 17.6% Space Heating 08 2.42 -0.44 - -22.2% Space Cooling c 79.79� 0,83 ,Ql T 9.94 0.83 is- fix' $ ...;. ?• ',,{l 9.85 0.00 12.3% 0.0% IAQ Ventilation k"T." Water Heating 3:03 4 2B3 t= 0.20 6.6% PV Credit H I F\ ' i f a i R C) &.00 ! ! . i .: 0,00 - South Facing Compliance Total 65.63 76.02 9.61 11.29E Space Heating 1.98 2.89 -0.91 -46.0% Space Cooling 79.79 64.27 15.52 19.5% IAQ Ventilation 0.83 0.83 0.00 O.D% Water Heating 3.03 2.83 0.20 6.6% PV Credit -. D.00 0.00 - West Facing Compliance Total 85.63 70.82 14.81 17.3% Registration Number: 217-P01D024973D-000-9oD-0000000-0ond Registration DateTme: 2017-11-201219:44 HERS Provider CaiCERTS Inc. CA Building Energy Efficiency Standards- 2016 Residential Compliance Report Version -CF1 R-09012017-934 SPi Report Generated at 2017-11.20 09:30:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #7(470D) Calculation DateTme: 09:30, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr397.ribdl6x C F1 R-PRF-01 Page 3 of 12 ENERGY DESIGN RATING Energy Design Rating (EDR) Is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" Its TDV energy. Because EDR Includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), It Is not used to show compliance with Part 6 but may Instead be used by local Jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building Is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of Installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency - EDR Value of Proposed PV + Battery Final Proposed EDR North 60.0 43.4 OA 43.4 East -_ 50.8 43.7 0.0 43.7 South 60.6 46.3 0.0 46.3 West 50.8 43.9 0.0 - _. 43.9 ❑ Design meets Tier 1 requirement of 16% or greater code compliance margin (CALGreen A4203.1.2.1) and 011 verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and Oil verification prerequisite. Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate lone CZ1S (Palm Spdn9s) (CALGreen A4.203.1.2.3) Including on -site photovoltaic (PV) renewable energy generation sufficient to ach[love a Final Energy Design Riling (EDR) otlero ortess. The PV System must be verified. t Notes: r. • Excess PV Generation EDR Credit: Bypassing Pv size limit ma violate Nei Ene Mclerin NEM rWes 4 - R REQUIRED SPECIAL FEATURES _ The following are features that must be installed as condition for:meefing'Ihe modeloAenergy perfonriat(ee'[oilhf"s eortiputei analysis.'"` ` ' • Non-standard roof reflectance • Window overhangs and/or fins • Nonstandard duct location (any location other than attic) • Recirculation with demand control, push button Registration Number. 217-P010024973D-ODO-OW-0000000-OODD Registration DateRme: 2017-11-2012:19:44 HERS Provider. CaiCERTS inc, CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version -CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 09:30:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #7(4700) Calculation Datefrime: 09:30, Mon, Nov 20, 2017 Page 4 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr397.ribd16x HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided In the building components tables below. Building -level Verifications: • High quality insulation Installation (Qll) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Ducts located entirely in conditioned space confirmed by duct leakage testing • Lowdeakage Air Handling Unit Domestic Hot Water System Verifications: -None- BUILDING - FEATURES INFORMATION Ot 02 03 04 - 05 OG 07 Project Name Conditioned Floor.Aroa (ftt)` :{Number of Dwelling, "'"Units ? rq» j '-"7-"�', Number of eedrooms. "" �' Number o)f 26P s Number of Ventilation Cooling Systems NumberofWater Heating Systems Griffin Ranch 2017 - Plan.#7(4700)' - 4700.,,, ' H,; s '1 ,-."„ ' ,... �e 'q. ,_• r $ 21 q ., s, 0 1 ZONEINFORMATION. 01 ... 02 03 04 05 06 07 Zone Floor Area Avg. Ceiling Zone Name. Zone Type HVAC System Name (ft=) Height Water Heating System 1 Water Heating System 2 UvinglOther Bedrooms Conditioned HVAC Living/Other Bedrooml 2800 12 DHW Sys.1 - - nfa M.Bedrooms Conditioned HVAC M. Bedrooms2 1900 12 DHW Sys 1 n/a Registration Number 217-P010024973D-000-000-0000000-0000 Registration DateRme: 2017-11-20 12:19:44 HERS Provider CeICERTS Inc. CA Building Energy Efficiency Sta:ldards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 09:30:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #7(4700) Calculation DatelTme: 09:30, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr397.ribdl6x CFIR-PRF-01 Page 6 of 12 OPAQUE SURFACES 01 02 03 04 _ 05 06 -07 - 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) window & Door Area (ft) Titt(deg) Front 24 Wall Living/Other Bedrooms R-21 Wall 0 _ . Front 12l 39 90 Left 2x6 Wall Living/Other Bedrooms R-21 Wall 90 Left 792 375.006 90 Back 2x6 Wall Living/Other Bedrooms R-21 Wall 180 Back 374 0 90 Right 2x6 Wall - Uving/Other Bedrooms R-21 Wall 270 Right 583 56 90 Front Garage Wall Living/Other Bedrooms» Garage_ R-15 Wail House/Garage We n/a 230 21 Na Right Garage Wall Living/Other Bedrooms- R-15 Wall House/Garage Na Na 180 0 Na -Garage -Right 2x6 Garage Wan Living/Other Bedrooms»_Garage_ R-21 Wall House/Garage Na nfa 230 0 Na Interior Surface Living/Other Bedrooms>>M.Bedrooms R-0 Want We Na 600 0 n/a Ceiling Below Attic Living/Other Bedrooms R30 Attic HPA Na nla 2800 Na We Front 2x6 Wall M.Bedrooms m¢'""'t' ✓( AOR-21 V611' ji�,:"� ;�" eO" Front 756 128 90 Left 2x6 Wall 2 _ M.Bedroms R-21,�a,ar`g 90, ;Leff} 576 133,3 90 Back 2x8 Wall - M. jf% ms '4`*v°-'4 N ou. a '*R-21%it9 0 0 I 60460 � t' lead? 756 158.7 90 Right 2x6Wall 2 M.Bedrooms. --� ;7 R ?221'Ml(;el P? �76 ( ! jRight 1-. 220 0 90 Ceiling Below Attic 2 M.Bedrooms R30 Attic HPA Na nla- 1900 We - Na FG Wall R-0 Wall 0 Front 230 128 90 RG Wall _Garage - - _Garage_ - R-0 Wall 270 Right 410 0 90 Garage Ceiling _Garage_ R-0 Garage Attic We Na 767 Na We ATTIC 01 02 03 04 05 06 07 - 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barter Cool Roof Attic Living/Other Bedrooms Attic RootLiving/Other Bedrooms Unventilated 3 016 0.89 No No Attic M.Bedrooms Attic RoofM.Sedrooms Unventilated 3 0.16 0.69 No No Attic_Garage_ Attic Garage Roof Cons Ventilated 3 0.16 0.89 .. No Registration Number: 217-P010024973D-000.000-0000D00-0000 Registration DateMme: 2017.11-20 12:19:44 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-0901 2017-934 SPt Report Generated at: 2017-11-20 09:30:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #7(4700) Calculation DateMme: 09:30, Mon, Nov 20, 2017 Page 6 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr397.ribdl6x FENESTRATION I GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ftz) U-factor SHGC Exterior Shading Front Fixed Wndow Front 2x6 Wall (Front-0) - 2.5 6.0 1 15.0 0.26 0.25 Insect Screen (default) Left Openable Wndow Left 2x6 Wall (left-90) - - 1 54.0 0.30 0.23 Insect Screen (default) Left Stacking Glass Door Window Left 2x6 Wall (Left-90) - 24.0 10.0 1 . 240.0 0.32 0,20 Insect Screen (default) Left Folding Window Wndow Left 2x6 Wall (Left-90) 910 5.0 1 45.0 0.32 0,20 Insect Screen (default) Lett Fixed - Window Loft 2x6 Wall (Left-90) 9.0 1.3 1.003 - 12.0 0.26 0.25 Insect Screen (default) Left Hinged Glass Door Window Left 2x6 Wall (Left-90) 3.0 8.0 1 24.0 D.30 0.23 Insect Screen (default) Right Openable Window Right 2x6 Wall (Right-270) - 1 56.0 0.30 0.23 Insect Screen (default) Front Openable Window Front 2x6 Wall 2 (Front-0) - - 1 38.0 0.30 0.23 Insect Screen (default) Front Fixed 2 Window Front 2x6 Wall 2 (Front-0) - - 1 20.0 0,26 0.25 Insect Screen (default) Front Stacking Glass Door - Window Front 2x6 Wall 2 (Front-0) 9.0 B.0 1 72.0 0.32 0.20 Insect Screen (default) Left Openable 2 Window Left 2x6 Wall 2 (Left-90) - - 1 96.0 0.30 0.23 Insect Screen (default) Left Fixed 2 Wndow Left 2x6 WaIt 2 (Le 1-41dJ^ ''•''` 'y =;{rr' '"`' > 1 „ 37.3 0,26 0.25 Insect Screen (default) Back Operable Window "�-' Back 2x6 Wall2 (Backk-160) (F"b "t- E- i Q _f 64.0 0.30 0.23 Insect Screen (default) Back Fixed Wndow yJ% Ba&24 Wjll2,(BacIR480) f6""` ' = + "1 f' "'2tl 0.26 0.25 Insect Screen (default) Back Slacking Glass Door Window - Back'2x6 Wall 2 (80itk-1p) [_-' '�9.0� f 't.,<6.0) ) 1 ,S: _ -�72.0 0.32 0.20 Insect Screen (default) OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft") U.factor Front Door Front 2x6 Wall 24.0 - 0,60. Front Garage Door Front Garage Wall 21.0 0.50 Car Door - FG Wall - 128.0 0.50 Registration Number 217-P010024973D-000.000-000000D-0000 Registration DateTme: 2017-11-20 12:19:44 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version -CF1 R-09012017-934 SP1 Report Generated at: 2017-11-2009:30:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #7(4700) Calculation DateTme: 09:30, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr397.ribd16x CF1 R-PRF-01 Page 7 of 12 _OVERHANGS AND FINS 01 02 03 04 OS _ OS 07 os 09 10 11 12 1 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Front Fixed 9 1 2 2 0 0 0 0 0 0 0 0 0 Left Stacking Glass Door 13 1 2 2 0 0 0 0 0 0 0 0 0 Left Folding Window 13 2.5 2 - 2 - 0- 0 0 0 0 0 0 0 0 Left Foxed 13 1 2 2 - 0 0 0 0 D 0 0 0 0 Left Hinged Glass Door 13 2.5 2 2 0 0 0 0 0 0 0 0 0 Front Stacking Glass Door 13 2.5 2 2 0 0 0 0 0 0 0 0 0 Back Stacking Glass Door 13 2.5 2 2 0 0 0 0 0 0 0 0 0 yp�*y� �1�.✓, (+fit=.:s C%.++b._ Y.t� �sY+n c. Fz L) f. Registration Number 217-P01oa24973D-0ODCOD.00DOO 0-0000 Registration Date lime: 2017-11-2a 12:19:44 HERS Provider Ca10ERTS Ina CA Building Energy Efficiency Standards -2016 Resldantial Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at 201741-20 09:30:50 I CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #7(4700) Calculation Datei-rime: 09:30, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr397.ribdl6x C F1 R-PRF-01 Page 8 of 12 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 - - 05 06 .07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers Ceilings (below Inside Finish: Gypsum Board R-0 Garage Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O,C. none 0.481 Cavi(y/Frame: no insu4. /2x4 • Inside Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.361 Exterior Finish: 3 Coat Stucco Cavity/Frame: no instil. / 2x4 Top Chrd • Roof Deck. Wood Siding/sheathing/decking 2x4 Top Chard of Roof Truss @ 24 Tile Gap: present Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. D.C. none 0.400 Roofing: 10 PSF (Reorr/le) • -Around Roor Joists: R-17.0Insul, • Cavity/Frame: R-13,0/20 Top Chrd • Roof Deck Wood Siding/sheathing/decking Attic Roofliving/Other 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Bedrooms Attic Roofs Wood Framed COMM in. O.C. R 30 0.040 Roofing: 10 PSF (RoorTile) R-30 Attic HPA Ceilings (below attic) Wood Framod 6pittg, ,t" k2x4 0 fn, 0 G. 1, � � none`r _ 0,461 inside Finish: Gypsum Board Cavity/Frame: no instil. /2x4 tte ;g Via. a Inside Finish. Gypsum Board Cavity/Frame: R-21 /2x6 R-21 Wall Exterior Walls VI;od Framed Wail •2x6 @ 16 in. O.C.. _ ,. R 21 , 0.069 Exterior Finish., 3 Coat Stucco '� • ! Inside Finish: Gypsum Board • Cavityy/Frame: R-15/2x4 R-15 Wall House/Garage Interior Wails Wood Framed Wall 2x4 @ 16 in, O.C. R 15 0.086 Other Side Finish:. Gypsum Board • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 R-21 Wall HouseiGarage Interior Walls Wood Framed Wall 2x6 @ 16 In. O.C. R 21 0.064 Other Side Finish: Gypsum Board inside Finish: Gypsum Board -• Cavity/Frame: no insul,/2x4 R-0 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.277 Other Side Finish: Gypsum Board • Around RoofJoists: R-17.0 instil. • Cavity/Frame: R-13,0/2x4 Top Chrd • R001DeCk Wood Siding/sheathing/decking 2x4 Tap Chord of Roof Truss @ 24 Tile Gap: present Attic RoofM.Bedrooms Attic Roofs I Wood Framed Ceiling in, D.C. R 30 0.040 Roofing: 10 PSF (RoorTile) Registration Number: 217-P010024973D-000-000-0000000-0000 Registration Date/Time: 2017-11-20 12:19:44 HERS Provider: CoICERTS Me. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at:2017-11-20 09:30:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #7(4700) Calculation Date/Time: 09:30, Mon, Nov 20, 2017 Page 9 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr397.ribd16x SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade Living/Other Bedrooms 2800 164 None 0,8 No Slabon-Grade2 M.Bedrooms 1900 194 .None 0.8 No Garage Slab _Garage_ - 767 - 64 - None 0 No BUILDING ENVELOPE - HERS VERIFICATION - 01 _ 02 03 04 Quality Insulation installation (Qil) -_ - Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 - Required Not Required Not Required n/a - WATER HEATING SYSTEMS 01 02 03 04- 05 06 Name System Type Distribution Type.. Water Heater Number or Heaters Solar Fraction I%) DHW Sys 1 Recirculation DHW With demand control, ush'txmon P �.-,, DHW Heater 1 1 _ ( ) ' F; ii 1 .0% WATER HEATERS 01. - - 02 _ 03 OS - ' .� _ Ofi" 07 A n ' Otl� � 10 11 12 Name Heater Element Type Tank Type �. Number of Units 1 _1 Tank Volume _ (gall Uniform Energy Factor/ Energy Factor Efficiency InpufRalingr/ Pilot / ' Thermal Efficiency `✓ Tankt-,J Insulation R-value (Int/Ext) LrStandby Loss / Recovery Eff First Hour Rating I Flow Rate NEEA Heat Pump Grand I Model Tank Location or Ambient Condition DHW Heater 1 Gas Consumer Instantaneous (UEF) 1 0 0,92 UEF 199,900 Btulhr 0 nfa 10 GPM n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling. Unit Name Fan Name Distribution Name HVAC Llving/Other Bedrooml Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC M.Bedrooms2 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 Registration Number 217-P010024973D-000-000MOOD0-0000 Registration DateRme: 2017-11-2012:19:44 HERS Provider. CaICERTS Inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CFIR-09012017-934 SP1 Report Generated at: 2017-11-20 09:30:50 t CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #7(4700) Calculation DateTme: 09:30, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr397.ribdl6x CF1R-PRF-01 Page 10 of 12 HVAC - HEATING UNIT TYPES ... 01 02. 03 D4 Name System Type Numberof Units Efficiency Heating Component 1 CnldFurnace 1 92 AFUE Heating Component 2 CntdFurnace - - - - 1 92 AFUE HVAC - COOLING U NIT TYPES 01 I 02 - - 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 12 14 Not Zonal Single Speed Cooling Component 1-herstool Cooling Component 2 SplitAirCond 1 12 14 Zonally Controlled Single Speed Cooling Component 2-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 Ol 04 its 06 Name VerlfiadAirflowF� �.'..'; Airtlw'1'arget?, !a,VerifiedEER i; r , Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool � ,gg*,d •'�^T�K `�+r'n' 4 '�tn,,r� k3 £ -. k .. �,Requlied'� t' "i ? n Not Required Required Cooling Component 2-hers-cool -- - - Regi9i r'gd t—J I-- }-j '• > 276: � 'I-,! t� i ;;' Req�ired j•— f Not Required Required HVAC- DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctslnAll Specified Lower Leakage Target 6 Conditioned zone None Air Distribution System 1-hers-dist Air Distribution System 2 DuctslMll Specified Lower Leakage Target 6 Conditioned zone None Air Distribution System 2-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 -08 Name Duct Leakage Verification Duct Leakage Target (Ye) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dlst Required 5.0 Required Not Required Not Required Not Required Required Air Distribution System 2-hers-0ist Required 5.0 Required Not Required Not Required Not Required Required Registration Number. 217-P0100249730-000-000-OOOOD00-0000 Registration Date/Time: 2017-11-20 12:19.44 HERS Provider. CaICERTS Inc. CA Building Energy EOidency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 09:30:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #7(4700) Calculation DateMme: 09:30, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr397.rihd16x CF1R-PRF-01 Page 11 of 12 HVAC-FAN SYSTEMS 01 - .__02 03 04 Name Type Fan Power (WattslCFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 -HVAC Fan 1-hers-fan HVAC Fan 2 S ng10 Speed PSC Furnace Fan 0150 - HVAC Fan 2-hers4an HVAC FAN SYSTEMS - HERS VERIFICATION Ot ... 02- 03 Name - Verified Fan Waft Draw Required Fan Efficiency (WattsfCFM): HVAC Fan 1-hers-tan Required 0.58 HVAC Fan 2-hers-fan Required - - 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 06 06 Dwelling Unit IAQ CFM IAQ WattsICFM IAQ Fan Type IAQ Recovery Effectiveness(;4) HERS Verification SFam IAOVentRpf 85 ,, ..m, ,ram+ 4.0.25 w ,!zr: w w Default D .Required Registration Number. 217-P010024973D-000.000-0000000-0000 Registration DateTme: 2017-11-2012:12:44 HERS Provider. CaICERTS inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1 R-09012017-934 SPt Report Generated at: 2017-11-20 09.30:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Gruen Ranct 2017 - Plan #7(4700) Calculation DatelTme: 09:30, Mon, Nov 20, 2017 Page 12 of 12 Calculation Description: Tile 24 Analysis Input File Name: Lennr397.ribdl6x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete, Documentation Author Name: Documentation Author Signature Rick Maurer Company: Signature Dale: Rick Maurer Title 24, Inc. 2017-11-20 12:18:55 CABEC urr.Wa, sue: ram r. crrwn.N Address: - CEAIHERS Certification Identification (If applicabl 7544 Saddlehill Trail R13-90-10024 Clty/Statel ip: - Phone: Orange, CA 92869 714-771-1507 RESPONSIBLE PERSON'S DECLARATION STATEMENT certify the following under penaty of perjury, under the laws of the Stale of Califomia: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Cerlificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the Information provided on other applicable compliance documents, worksheets, calculations,, plans and specifications submitted to the enforcement agency for approval. With (Ms building permit application. Responsible Designer Name: - - '" L' ,,,,,, £ Responsible DesignerSloiatuto.t- p`""lf �5' James Jenike ,,z ( a we<rt.F¢ Company: `^l:' 1 1 7 Date Signed:t .... Lennar Homes - Southerni CA 2017-11-20 12:19:4' Address: License: 980 Monteclto Drive, Suite 302 Citylstate0p: - Phone: Corona, CA 92879 951-817-3500 Digitally signed by Ca1C£RTS. This digital signature is provided in order to secure the content of this registered document and in noway Implies Registration ilm Provider responsibility for the accuracy of the in formation Easy to Verity at CaICERTS.com Registration Number 217-P01002�9731)-000-000A000000-0000 Registration DatefTime: 2017_11-2012:19:44 HERS Provider. CaICERTS ins CA Building Energy Efficiency Stanyards- 2016 Residential Compliance Report Version - CFl R-C9012017-934 SP1 Report Generated at: 2017.11-20 09:30:50 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - Plan #7(4700) Date 11/20/20,17 System Name HVAC Living/Other Bedrooms Floor Area 2,800 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1;602 Return Vented Lighting Return Air Ducts Return Fan Ventilation o Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 80.000 33,711 3.7.671 685 26,853 Total Output Btuh 80,000 0 Output Btuhls ft 28.6 522 331 Cooling Systern 0 0 Output per System 60,000 0 01 0 0 Total Output Btuh 60,000 0 522 34,755 3,767 0 Total Output Tons 5.0 331 Total Output Btuhls ft 21.4 Total Output s fUTon 560.0 27,514 Air System CFM perSystem 2,200 HVAC EQUIPMENT SELECTION Airflow cfm 2,200 Liv/Bed.HVAC Equipment Selection & Sizing by 6thi 39,654 11,234 80,000 80,000 Jan 1 AM Airflow cfm/s ft 0.79 - Airflow cfm/Ton 440.0 Outside Air % 0.0°% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 39,654 11,234 Outside Air cfmfs ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 68 of 105 OF Outside Air ` ��...»..,�........FM...�.,.• 0 cfm Supply Fan Heating Coil 2,200 cfm 68 OF ll 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF 75J62°F 75/62°F 55/54°F Outside Air' _ HTI �-E 0 elm Supply Fan Cooling Coil 2,200 cfmI 75 / 62 OF _-i 55 / 54 OF 48.2% { ROOM 75 162 OF ZnergyPro 7.2 by EnergySolf User Number. 1686 ID: Page 15 of 16 A 0 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - Plan #7(4700) Date 11/20/2017 System Name HVAC M. Bedrooms Floor Area 1,900 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,241 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK System Sensible Latent CFM Sensible -Heating Output perSystem 80,000 26,194 2,556 598 23,464 Total Ou ut Btuh 80,000 0 output Btuh►s ft 42.1 406 289 System 0 0 -Cooling Outputper stem 60,000 0 0 0 0 Total out ut. Btuh 60,000 0 4061 1 27,005 2,556 0 Total Output Tons 5.0 289 Total Output Btuh/s ft 31.6 Total Output s ft/Ton 380.0 24,042 Air System CFM perSystem 2.200 HVAC EQUIPMENT SELECTION Airflow cfm 2,200 M.Bed,HVAC Equipment Selection & Sizing by Othe 39,958 10,759 80,000 Airflow cfm/s ft 1.16 Airflow cfmrron 440.0 Outside Air % 0•0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 39,958 10,759 80,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions F Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 68 OF 105 IF Outside Air 0 cfm Supply Fan Heating Coil 2,200 cfm 68 OF SIC 4 105 OF ROOM 68 °F COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 75 l 62 IF 75162 OF 55 / 54 IF t�'' ♦ Outside Air 0T. 0 cfm Supply Fan Cooling Coil 2,200 cfm 75 / 62 OF j U� I ---!_U 55 / 54 OF 47.5% FR66m in 75162 OF EnergyPro 7.2 by EnergySoff User Number: 1686 1D: Page 16 of 16 BUILDING ENERGY ANALYSIS REPORT PROJECT: Lennar Homes - Plan #8(4820) Griffin Ranch 2017 La Quinta, CA Project Designer: Lennar Homes 980 Montecito Drive, #302 Corona, CA 92879 951-817-3600 Report Prepared by: Rick Maurer Rick Maurer Title 24 7544 Saddlehill Trail Orange, CA 92869 714-771-1507 Job Number: Date: 11 /20/2017 The EnergyPro computer program has been used to perform the calculations summarized In this compliance report. This program has approval and Is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. P 0 TABLE OF CONTENTS Cover Page Table of Contents Form CF-1 R-PRF-01-E Certificate of Compliance HVAC System Heating and Cooling Loads Summary EnergyPro 7.2 by, EnergySoft Job Number ID: User Number. 1686 1 2 3 15 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #8(4820) Calculation Date/Time: 09:55, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr424.ribdl6x CFI R-PRF-01 Page 1 of 12 GENERAL INFORMATION _ 01 Project Name Griffin Ranch 2017 - Plan 08(487.0). 02 Calculation Description Title 24 Analysis 03 Project Location Griffin Ranch 2017 04 City. Le Quinta 06 _ Standards Version Compliance 2017 06 Zip. Code 07 Compliance Manager Version BEMCmpMgr 2016.3.0 (934 SPt) 08 Climate Zane CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family if Front Orientation (degfCardindl) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 4820 15 Number ofZones 2 16 Slab Area (ft) 4020 17 Number of Stories 1 18. Addition Cond. Floor Area(ftz) n/a 19 Natural Gas Available yes 20 Addition Slab Area (R) I n/a 21 Glazing Percentage (%) 1 &9% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building Incorporates features that. requtre fie(0lesting and/or votificeilon;by a ciijiif0i1 HERS Q0,xndar the supervisiobola CEC-approved HERS provider. 03 e.rx+�- - This building Incorporates one or moroySliodal Fea)ures shown ti'eiow" j$ Registration Number: 217-P0100021400-000-000-0000000-0000 Registration DateMme: 207-11-20 12:19:46 HERS Provider. CaICERTS Inc, CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version -CFI R-09012017-934 SPt Report Generated at 2017-11-20 09:56:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #8(4820) Calculation DateMme: 09:55, Mon, Nov 20, 2017 Page 2 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr424.ribd16x ENERGY USE SUMMARY - Energy Use Standard Proposed Compliance Percent (kTDVrrt2-yr) Design Design Margin Improvement Space Heating 2.05 2.27 -022 -10.7% Space Cooling 79.82 63.14 16.68 20.9% IAQ Ventilation 0.82 0.82 0.00 0.0 % Water Heating 2.95 2.76 0.19 6A% PV Credit - 0.00 0.00 - North Facing Compliance Total 85.64 68.99 16.65 19.4116 Space Heating 2.05 2.40 -0.35 -17A% Space Cooling 79.82 67.49 12.33 15.4% IAQ Ventilation 0.62 0.82 0.00 0.0% Water Heating 2.95 2.76 0.19 6.4% PV Credit -. 0.00 0.00 - East Facing Compliance Total 05.64 73AY 12.17. 14.2% Space Heating 2.051t 2.73 -0.68 33.2 % 811 w 9.69 16.13 20.2% Space Cooling IAQ Ventilation 2 C C Er •82 0•� 0.0% Water Heating ye ( 95 ij � 2�761' t x { ^^ 0.19 6.4% PV Credit +' ; i t'.=- F', ? 1i:po • . f •. 0.00 - South Facing Compliance Total 85.64 70.00 16.64 18.3% Space Healing 2.05 2.37 - -0.32 -15.6% Space Cooling 79.82 63.85 15.97 20.0% IAQ Ventilation 0.82 0.82 0.00 0.0% Water Heating 2.95 2.76 0.19 6A% PV Credit - 0.00 0.00 - West Facing Compliance Total 85.64 69.00 15.84 18.5% Registration Number 217-Po1oo021490-000-Oo9-0000000-0000 Registration DatelTme: 2017-11-20 12:19:46 HERS Provider CaICERTS Inc, CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SPt Report Generated at 2017-11-20 09:56:19 I 't CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Gruen Ranch 2017 - Plan #8(4820) Calculation DatetTme: 09:55, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr424.ribdl6x CFI R-PRF-01 Page 3 of 12 ENERGY DESIGN RATING Energy Design Rating (EDR) Is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" Its TDV energy. Because EDR Includes consideration of components not regulated by Title 24, Pan 6 (such as domestic appliances and consumer electronics), it Is not used to show compliance with Part 6 but may Instead be used by local Jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards Is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building Is provided for Information. Similarly, the EDR score of the Proposed Design Is provided separately from the EDR value of Installed PV so that the effects of efficiency and renewable energy can both be seen - EDR of Standard Efficlency .. EDR of Proposed Efficiency _ EDR Value of Proposed PV + Battery Final Proposed EDR North 60.8 42.9 0.0 42.9 East 50.8 45.1 0.0 45.1 South 60.8 43.4 0.0 43.4 - West 60.8 43.3 0.0 43.3 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and Oil verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. - Design meets Zero Net Energy(ZNE) Design Designation requirement for Single Family In climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) Including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. Notes:.. • Excess PV Generation EDR Credit: Bypassing, -Pvstze ltmil ma violate°Net EnergyMeteringNEM rules - $ REQUIRED SPECIAL FEATURES' .- a r r v The following are features that must be installed as condition tar meetind "muddled energy' performaiice`'.fWthrs compute' afkalysts,- • Non-standard roof reflectance - - Window overhangs and/or fins • Non-standard duct location (any location other than attic) • Recirculation with demand control, push button Registration Number 217-P010002140D-000-00D-0e00oee-0000 Registration DateRme: 2017-11.20 12:19:46 HERS Provider. CeICERTS inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CFtR-09012017-934 SP1 Report Generated at: 2017-11-20 09:55:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #8(4820) Calculation DateTme: 09:55, Mon, Nov 20, 2017 Page 4 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr424.ribdl6x HERS FEATURE SUMMARY The fallowing is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below, Building -level Verifications: - High quality Insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing - Ducts located entirely In conditioned space confirmed by duct leakage testing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: —None -- BUILDING - FEATURES INFORMATION 01 02 03 - 04 05 06 07 dNumber of Dwelling' 1-1 )g"'"p ` L4 " �41 " Number of Ventilation Number of Water Project Name Conditioned Floor Area (fi2); r' UNts !- Number of Bedrooms Number of Zones.=" Cooling Systems Heating Systems Griffin Ranch 2017 - Plan #8(4820) 4820.,, fit: 1 _.;. C . Al Q a R4 i; 3' .= w ,. 0 1 ZONE INFORMATION `— f'" 01 02 03 04 05 06 07 Zone Floor Area Avg. Ceiling Zone Name Zone Type HVAC System Name (fill Height Water Heating System 1 Water Heating System 2 Living/Guest Conditioned HVAC - Living/Guesll 2800 12 DHW Sys 1 nla Bedrooms Conditioned HVAC - Bedrooms2 202D 12 DHW Sys 1 nia Registration Number 217-P010002140D-000-000-0000000-0000 Registration DateRme: 2017-11-20 12:19:46 HERS Provider. CeICERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-20 09:56:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan 0(4820) Calculation DateMme: 09:55, Mon, Nov 20. 2017 Calculation Description: TiOe 24 Analysis Input File Name: Lennr424.dbdl6x C F1 R-PRF-01 Page 5 of 12 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azlmuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) Front 2x6 Wall Living/Guest R-21 Wall 0 Front 319 100 90 Left 2x6 Wall Living/Guest R-21Wall 90 Left. 462. 30 -. 90 Back 2x6 Wall Living/Guest - - - R-21 Wall 180 Back - 852' - M6 - 90 Right 2x6 Wall LiAng/Guest R-21 Wall 270 Right 583 61 90 Front 2x8 Garage Wall Living/Guest»_Garage_ R-21 Wall House/Garage Na We 420 42 n/a Right 2x6 Garage Wall Living/Guest»_Garage_ R-21 Wall House/Garage n/a We 210 0 n/a Interior Surface Living/Guest—Bedrooms R-0 Walll n/a n/a 450 0 n/a Ceiling Below Attic Living/Guest R-30 Attic HPA n/a - n/a 2800 n/a n/a Front 2x6 Wall 2 Bedrooms R-21 Wall 0 Front _ 350 5o 90 Left 2x6 Wall 2 - - - - Bedrooms R-21 Wall -so Left 814 85.5 90 Back 2x6 Wall 2 Bedrooms R-21 Wall 180 Bads 384 132 90 Right 2x6 Wall Bedrooms R-21 Wall 270 Right 441 64.5 90 Ceiling Below Attic 2 Bedrooms �° , .�, -30 AWc HPA;°r, ?:. "a � gn/a,. ..r r 2020 - We - n/a FG Wail _Garage ")lJ R-0 Wall J ffroril 420 744 90 .. .. LG Wail _Garage JI-O van'-> _ ,., _.- 90, %_ };,. Loft 110 0 90 RG Wall _Garage a R'-0 Walr f , '� 2710 t Right I 220 72 90 RG Wall _Garage_ R-0 Wall 270 Right 100 0 90 Garage Ceding _Garage_ R-0GarageAttic nla n/a 716 n/a - n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Coot Roof Attic Living/Guest AIOc RoofHAN/Guest Unventilated 3 0.16 0.89 No No Attic Bedrooms - Attic RoofBedrooms Unventilated 3 0.16 0.89 No No Attic Garage_ Attic Garage Roof Cons Ventilated - 3. 0.16 0.89 - No No Registration Number: 217-Po10002140D-000-0004000000-0000 Registration Date/Time: 2017-11-2012:19A6 HERS Provider. CaiCERTS Inc, CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFI R-09012017-934 SP1 Report Generated at: 2017-11-20 09:56:19 f CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #8(4820) Calculation Daterrime: 09:55, Mon, Nov 20, 2017 Page 6 of 12 Calculation Description: Tine 24 Analysis Input File Name: Lennr424.ribd16x FENESTRATION f GLAZING 01 02 03 04 05 06 07 08 09 10- Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (11:2) O-factor SHGC Exterior Shading Front Fixed Window Front 2x6 Wall (Front-0) 4.0 6.0. 1 24.0 0.26 0.25 Insect Screen (default) Front Sliding Glass Door Window Front 2x6 Wall (Front-0) 6.0 8.0 1 48.0 0.28 0.22 Insect Screen (default) Left Openable - Window Left 2x6 Wall (Left-90) 2.0 6.0 1 12.0 0.30 0.23 Insect Screen (default) Left Openable 2 Window Lett 2x6 Wall (left-90) 3.0 6.0 1 18.0 0.30 0.23 Insect Screen (default) Back Fixed Window Back 2x6 Wall (Back-180) 16.0 1.5 1 24.0 0.26 0.25 Insect Screen (default) Back Stacking Glass Door Window Back 2x6 Watl (Back-180) 16.0 8.0 1 126.0 0.32 0.20 Insect Screen (default). Back Slacking Glass Door 2 Window Back 2x6 Wall (Bards-180) 24.0 -10.0 1 240.0 0.32 0.20 Insect Screen (default) . Back Hinged Glass Door Window Back 2x6 Wall (Back-180) _ 3.0 8.0 1 24.0 0.30 0.23 Insect Screen (default) Right Openable Window Right 2x6 Wall (Right-270) - - 1 15.0 0.30 0.23 insect Screen (default) Right Openable 2 Wndow Right 2x6 Wall (Right-270) - 1 36.0 0.30 0.23 Insect Screen (default) Right Operable 3 Window Right 2x6 Wail (Right-270) - - 1 - 10.0 0.30 0.23 Insect Screen (default). Front Fixed 2 Wndow Front 2xo wall 2 (Fronf-0) ° V"' -- -- 1 __6.0 0.26 0.25 Insect Screen (default) Front Operable - Window Fi'onl 2x6 Wa0 2;(Front-0) ,i.. -- "' q'1 @ 36.0 0.30 0.23 Insect Screen (default) Front Openable 2 Window Front 2z6 VIM 2 (Front-0)- - � r^�`-,'' " � 1 6 �6.5` 0.30 0.23 Insect Screen (default) -Left Operable 3 Window Left 2>(6 Wail 2 4.efl-90). 1 17.0.. , �„ i6.0' 7 1='- - 42.0 0.30 0.23 Insect Screen (default) Left Fixed Window Left 2x6 Wall 2 (1-e11-90) 7.0 1.5 1 10.5 0.26 0.25 Insect Screen (default) Left Openable 4 Window' Left 2x6 Wall 2 (left-90) - - 1 8.0 - 0.30 0.23 Insect Screen (default) Left Openable 5 Window Left 2x6 Wall 2 (Left-90) 5.0 5.0 1 25.0 0.30 0.23 Insect Screen (default) Back Fixed 2 - Window Back 2x6 Wall 2 (Back-180) 6.0 1.5 1 9.0 0.26 0.25 Insect Screen (default) Back Hinged Glass Door 2 Window Back 2x6 Well 2 (Back-180) 6.0 8.0 1 48.0 0.30 0.23 Insect Screen (default) Back Fixed 3 Window Back 2x6 Wall 2 (Back-180) 10.0 1.5 1 15.0 0.26 0.25 Insect Screen (default) Back Fixed 4 Window Back 2x6 Wall 2 (Back-180) 6.0 6.0 1 36.D 0.26 0.25 Insect Screen (default) Back Openable Window Back 2x6 Wall 2 (Back-180) 4.0 BA 1 24.0 0.30 0.23 Insect Screen (default) Right Fixed Window Right 2x6 Wall 2 (Right-270) 3.0 1.5 1 4.5 0.26 0.25 Insect Screen (default) Right Hinged Glass Door Window Right 2x6 Wall (Right-270) 3.0 8.0 1 24.0 0.30 0.23 Insect Screen (default) Right Openable 4 Window Right 2x6 Wall 2 (Right-270) -- - 1 36.0 0.30 0.23 Insect Screen (default) Registration Number: 217-P010002140D400-000-0000000-0000 Registration DateMmD: 2017-11-20 12:19:46 HERS Provider. CaICERTS Inc, CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2017-11-20 09:56:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #8(4820) Calculation Date✓ ime: 09:55, Mon, Nov 20, 2017 Calculation Description: Title 24 Analysis Input File Name: Lennr424.ribdt6x CFIR-PRF-01 Page 7 of 12 OPAQUE DOORS - Name Side of Building. Area (h2) U4actor Front Dow - - - Front 2x6 Wall 28.0 0.50 Front Garage Door Front 2x6 Garage Wall 42.0 0.50 Car Door FG Wall 144.0 0.50 Car Door 2 RG Wall 72.0 0.50 OVERHANGS AND FINS - - 01 02 03 -04 05 ..06 07 08 09 10 - 11 12 13 14 - - - - Overhang Left Fin Right Fin - Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L sot Up - Depth Top Up Dist R Bot Up Front Fixed 2 2 2 2 0 0 0 0 0 0. 0 - 0 0. Front Sliding Glass Door 10 2 2 2 0 0 0 0 0 0 0- 0_ 0 Lett Openable 12 2 ,...»,2- ,:. 2 _.. ._. 0,__, 0 _._ 0 0 0 0 0 0 0 Left Openable 2 _6 1.5 / ' 2 ,�' ..... a .0 0 ) > , 0,— 0 0 0 0 0 .. Back Fixed _. 10. .�:.- qj0.5 a... 2x 3. 'z_ 01 1 - j _0' ;. 0 ij 0 - 0 0 0 0 Back Stacking Glass Door 10 93 ,2 .. 2 ,,.. , 0 _ .0 �, 0 _ Oa _ 6 0 0 0 0 Back Stacking Glass Door 2 14 0:5 1 f2 -2 "� ' 0 s "`• 0 ° 0— w 0' ' 0 0 0 0 0 Back Hinged Glass Door 10 2 2 2 0 0 0 0 0 0 0 0 0 ..Left Openable 3 1.5 4 2 2-- 0 0 0_ 0 0 0 0 0 0 - Left Fixed - 1.5 1.5 2 2 0 0 0 0 0 D 0 0 0 Lett Operable 5 1.5 2 2 2. 0 0 0 0 0 0 0 0 0 Back Fixed 2 14 0.5 2 2 0 0 0 0 0 0 0 0 0 Bade Hinged Glass Door 2 14 3 2 2 0 0 0 0 0 0 0 0 0 Back Fixed 3 7 0.5 2 2 0 0 0 0 0 0 0 0 0 Back Fixed 4-.-7 - - 3 2 2 0 0 0 0 0 0 0 0 0 Back Openable, 7 3 2 2 0 0 0 0 0 0 0 0 0 Right Fixed 14 1.5 2 2 0 0 0 0 0 0 0 0 0 Right Hinged Glass Door 14 3 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 217-PO1000214OD-00D-000-0000000-0000 Registration Daterrime: 2017-11-20 12:19:46 CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1R-09012017-934 SPt HERS Provider. CWCERTS inc. Report Generated at 2017-11-20 09:56:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #8(4820) Calculation Date/Time: 09:55, Mon, Nov 20, 2017 Page 8 of 12 Calculation Description: Tite 24 Analysis Input File Name: Lennr424.dbdl6x OPAQUE SURFACE CONSTRUCTIONS of 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U.factor Assembly Layers Ceilings (below Inside Finish: Gypsum Board R-0 Garage Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: no insul./2x4 - Inside Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O,C. none 0.361 Exterior Finish: 3 Coal Stucco Cavity/Frame: no insul. / 2x4 Top Chrd • Roof Deck: Wood Siding/sheafhing/decldng 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic Garage Root Cons Attic Roofs - Wood Framed Ceiling In. D.C. none 0.400 Roohng; 10 PSF (RoofTile) Around Roof Joists: R-17.0 insul. • Cavity/Frame: R-130/2x4 Top Chrd • Roof Deck: Wood Siding/sheathing/decking 2x4 Top Chard of Roof Truss @ 24 Tile Gap: presen! Attic Roof Living/Guest Attic Roofs Wood Framed Ceiling In. O.C. R 30 0.040 Roofing: 10 PSF (Roof7ile) Ceilings (below Inside Finish: Gypsum Board R-30 Attic HPA attic) Wood Framed Ceiling 2x424 i� O C u�i:-�� none; 0.481 Cavity/Frame: no insul./2x4 •`•%ass '�y, t8r Inside Finish: Gypsum Board t,;,� T:? �- >.r.., T� i;+' r. S i :.� r; Cavity/Frame: R-2i /2x6 R-21 Wall Exterior Walls -•[--Wood Framed Wall _. 2x6 @ 16 ilr. O.C. ° R 21,,,,, r 0,069 Exterior Finish: 3 Coat Stucco '4 r 1 c f ✓ 1 c r _ .. ' Inside Finish: Gypsum Board • Cavily/Frame: R-21 /2x6 R-21 Wall House/Garage Interior Walls Wood Framed Wall - 2x6 @ 16 in. O.C. R 21 0.064 Other Side Finish: Gypsum Board Inside Finish: Gypsum Board • Cavity/Frame: noinsul. /2x4 R-0 Weill Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.277 Other Side Finish: Gypsum Board • Around Roof Joists: R-17.0lnsul. • Cavity/Frame:R-13.0/2x4Top Chrd • Roof Deck: Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present Attic RoofBadrooms Attic Roofs Wood Framed Ceiling in. O.C. R 30 0.040 Roofing: 10 PSF (RoofTila) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Instil. R-value R Depth Carpeted Fraction Heated Slab -on -Grade - Living/Guest 2800 195 None 0.8 No Slab -on -Grade 2 Bedrooms 2020 183 None 0.8 No Garage Slab _Garage_ 716 65 None 0 No Regisuafion Number 217-P010002-400-000-000-0000000-0000 Registration DateRme: 2017-11-20 12:19A6 HERS Provider. C210ERTS Inc. CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CFIR-09012017-934 SP1 Report Generated at: 2017-11-20 09:56:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Gruen Ranch 2017 - Plan #8(4820) Calculation Date/Time: 09:55, Mon, Nov 20, 2017 Page 9 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr424.ribdl6x BUILDING ENVELOPE - HERS VERIFICATION 01 - - 02 - - - - 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater- Number of Heaters Solar Fraction I%) DHW Sys 1 DHW Recirculation with demand control, push button DHW Heater 1 (1) 1 .01A WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Un1ts. Tank Volume (gal) Uniform Energy Factor Energy Factor Efficiency Input Rating Pilot Thermal Efficiency I Tank Insulation R-value (IntlExt) Standby Loss Recovery EH First Hour Rating I Flow Rate NEFA Heat Pump - Brand I Model Tank Location or Ambient Condition DHW Heater 1 Gas Consumer Instantaneous (UEF)..rk 1 $ 0 t, 042 UEF 199.900 Blulhf. m 0 + nl ,,,r 10 GPM r . n/a SPACE CONDITIONING SYSTEMS r 01 '' 02 t ..,�^ 03 y.. ., r04' s_ t 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC - Living/Guestl Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - Bedmoms2 Other Healing and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units - Efficiency- Heating Component 1 - CntrIFumece - - - _ 2 92 AFUE Heating Component 2 - CntriFumace I 92 AFUE Registration Number 217-P010002140D-000.000-00000000000 Registration DateTme: 2017-11-20 12:19:46 HERS Provider. CaICERT6 inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at 2017-11-20 09:56:19 13 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Griffin Ranch 2017 - Plan #8(4820) Calculation DateMme: 09:55, Mon. Nov 20, 2017 Calculation Description: Tide 24 Analysis Input File Name: Lennr424.ribdl6x CFI R-PRF-01 Page 10 of 12 HVAC - COOLING UNIT TYPES 01 02 07 04 1 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 2 12 14 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 1 12 14 Zonally Controlled Single Speed Cooling Component 2-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 06 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Not Required Required Cooling Component 2-hers-cool Required 275 Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 . ,: OS c=" ' '.�:z { +<. e�.�0d,• R ... 12 05 06 07 Name Type J" �,DlicCLeakage K`" ., 'glnaulatloil R-v`alue :t D'tict Location Bypass Duct HERS Verification Air Distribution System 1 DuctstnMB $i Spedlled tower Leakage' - Ter et b T l s 6 /• Conditioned zone None Air Distribution System 1-hers-dlst Air Distribution System 2 DuctslMll Spedfii:d LoTarget 6 Conditioned zone None Air Distribution System 2-erYeakage hers -list HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 06 06 07 08 Name Duct Leakage Verification Duct Leakage Target I%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handier Air Distribution System 1-hers-disc Required 5.0 Required Not Required Not Required Not Required Required Air Distribution System 2-hersd st - Required 5.0 Required Not Required Not Required Not Required Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC Fan 2 - Single Speed PSC Furnace Fan 0.58 HVAC Fan 2-hers4an Registration Number 217.PO1000214OD-000-000-00OOWD-0000 Registration Date/Time: 2017-11-20 12:19:46 HERS Provider. CeICERTS Inc. CA Building Energy Efficiency Star dards - 2016 Residential Compliance Report Version - CFI R-09012017-934 SP1 Report Generated at: 2017-11-20 09:50:19 1 ti CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #8(4820) Calculation Date/Time: 09:55, Mon, Nov 20, 2017 Page 11 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr424.ribdl6x HVAC FAN SYSTEMS - HERS VERIFICATION Name VerMed Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 HVAC Fan 2-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 - 03 04 .. Os. .._ - 06 Dwelling Unit IAQ CFM U1Q WattsICFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam1AQVenIRpt 86 _ - 0.25 Default 0 Required Ca"I RTS, Inc. f." r V I E) F F-11 Registration Number. 217-P010002140D-000-000-0000000-0000 Registration DateRme: 2017-tt-20 12:19:46 HERS Provider CaICERTS Mc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017.934 SPI Report Generated at 2017-11-20 09:56:19 - .e. a CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Griffin Ranch 2017 - Plan #8(4820) Calculation Daterfime: 09:65, Mon, Nov 20, 2017 Page 12 of 12 Calculation Description: Title 24 Analysis Input File Name: Lennr424.dbdl6x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete, Documentation Author Name: Documentation Author Signaturr, Rick Maurer Company: Signature Date: Rick Maurer Title 24, Inc. 2017-11-20 12:18:55r�✓gvE�— :JR:M.a R,Nr4(Ewd M4ti1I r'P4Y(ti-.uXsu, Address: CEAIHERS Certification Identification (If applicabl 7544 Saddlehill Trail R13-90-10024 Citylstale2ip: - - Phone: Orange, CA 92869 714-771-1507 RESPONSIBLE PERSON'S DECLARATION STATEMENT certily the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design Identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements Write 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for oppro4al,wlth this Adding permit application. Responsible Designer Name: ;`+ 4+„ „ { R Responsible DesignecSlgnattrret`• James Jenike Company: r , Date Signed: Lennar Homes - Southern CA 2017-11-20 12:19:46 Address: License: 980 Montecito Drive, Suite 302 Citylstale2ip: Phone: Corona, CA 92879 951-817-3500 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Easy to Verify at CoICERTS.com Registration Number. 217-P010002140D-000.000-0000000-0000 Registration Dateinme: 2017-11-20 12:19:46 HERS Provider. CACERTS ina CA Building Energy Efficiency Staldards -2016 Residential Compliance Report Version - CF1 R-09012017-934 SPt Report Generated at: 2017-11-20 09:56:19 " Of HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - Plan #8(4820) Date 11/20/2017 System Name HVAC - Living/Guest Floor Area 2,800 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1.659 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK System Sensible Latent CFM Sensible -Heating Output per System 64,000 35 027 3,7071760 29,819 Total Out ut. Btuh 128,000 0 Output Btuhls ft 45.7 •542 367 System 0 0 -Cooling Output per System 42,000 0 0 0 0 Total Output Btuh 84,000 0 542 36,112 3,7671330,554 0 Total Output Tons 7•0 367 Total Output Btuhls ft 30.0 Total Output s fUTon 400.0 Air System CFM perS tom 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 3,200 Liv/Gst.HVAC Equipment Selection & Sizing by Ottv 55,340 15,667 128,000 Airflow cfm/s ft 1.14 Airflow cfm/Ton 457.1 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 55,340 15,667 128,000 Outside Air cfmis ft 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 26 OF 68 OF 68 OF 105 OF Outside Air �•----� 0 cfm Supply Fan Heating Coil 3,200 cfm 68 OF ---I--� 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112 / 78 IF 75162 OF 75 / 62 IF 55 / 54 OF -77 O* Outside Air A 0 cfm Supply Fan Cooling Coil 3,200 cfm 75 / 62 OF j 55 / 54 °F 47.5% 1 ROOM 75162 IF EnergyPro 7.2 by EnergySoff User Number. 1686 10: Page 15 of 16 r ,r. d HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lennar Homes - iPlan #8(4820) Date 11/20/2017 System Name HVAC - Bedrooms Floor Area 2,020 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL .CFM Total Room Loads 1,214 Return Vented Lighting Return Air Ducts Return Fan Ventilation E o Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 80,000 25,619 2,7181 552 21,653 Total Output Btuh 80,000 0 Output Btuhls ft 39.6 397 267 System 0 0 -Cooling Output perSystem 60,000 0 0 0 0 Total Output Btuh 60,000 0 397 26,412 2,718 0 Total Ou ut Tons 5.0 267 Total 0 u1put Btch1s ft 29.7 Total Output s fNTon 404.0 22,186 Air System CFM per System 2,200 HVAC EQUIPMENT SELECTION Airflow cfm 2,200 Bed.HVAC Equipment Selection & Sizing by Others 39,901 10.837 80,000 Airflow cfm/s ft 1.09 80,000 Jan 1 AM Airflow cfmnlon 440.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1 39,901 10,837 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 68 OF 105 °F ---.I�_�_.l- Outside Air 0 cfm Supply Fan Heating Coil 2,200 cfm 68 OF 4 UT 1.- 0 4 -- 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112 / 78 IF 75162 IF 75 / 62 IF 55 / 54 IF fC�ir Outside Air 0 cfm Supply Fan Cooling Coil 2,200 cfm 75/62OF f 55 / 54 OF 47.60% I R O 75/62OF EnergyPro 7.2 by EnergySoR User Number. • 1686 ID: Page 16 of 16 L �s S m, Sx t tz7F, o x 8- 5 „ • rZy,,, . - � tax r O - Z`l b � • �.Yim. 37�1�'= y.� F, yl�uL7l-s�It�� Z )oo = ty (Lb 3�2, 4xco=-t-I !II►� • • 4,`Zyr7. 3 x 6 =1 8' • • rp1 N - Z- K to = 2 4 �- ) • • BVT-,� 1 ti x �$ 1 c to Ctl F-. • • : t,%V %ON'f g- TOTAL C-t LAM I W C, = a1�r. ARE 30`{ �.FT S KYLIQAT-S n T m C4IA ) 7-A z.x co =Z4 (L-) ToTAL ., 7 2 Z 3 r / �o M S. qf A1N AREA _..:.PLAN.: Z 3 x ,r Ly Fio Z co ?� to = 1 5 �§g5 zS 3 x �- _• b • ��dl1v� 33) y sQ.FT. m,v3✓�, 14 - $ F, r-, y 17-5 .b v».)5A y,q3_ Itt`-�•F, • k t z-/ nrx— W x S o 5 vv) rvac� w �c I r jO.co r—, yy 1y(1 gz) 7a5,�o TOTAL_ %LA--7,-IWC Z 3 (—:+ �o r AREA : ,..PLAN :.3 y-n , y3,�, v x i = C? yy1.r�r� �xc6= 9cLr�, F, �KYLIG,HTS ' 0Sn, 3 x flvr �a Or Y14 vr,~r I ,92 x = S �� / 9' t%-/ 10- , • biry . �bxi� ; I,�,StLIF 2b X 1 `- 7. 1 F Zx y = 1 �o tom, GlarzAc�E TOTAL GILA-4INGi= �4 1 57 PLAN-4 3 al S" sue.FT _e -r-►-$LI0F en , "AP, 1-.�4 X <v = 1110 � 2 Y ly O Vila, Y Z X 15,3(LI F 0010 1 13k7, tl o t7 2 N -b X fv = 3 �p Ql-) L r4-V M 7� 2Y(40-2`!106,) 3 � �Y � 8'C�•1 F N LA 1 514 eq. FT. � , ✓s✓�, Z 3 X ! y = Si' S =3b F. d ►3J.y - X�o =34p t3 ry S• • 1X a- = spv • Y3Ma��3r�.S••3x 6 = 3� tL) m.v3�•.� Z x 3 = � �) �w3 � `t _ �, 1 3 2� �rel�"' rr hs�o • z � r x 11 F• ram .�3 i�-�T�Nw•zx y 3y.7 1'Yi ) i X.t O : ! 14 Cj Wi v T ! —5 L 1 b{ i K� T�N!'�•� Q! x S = �! O PO09cs T-/ IV s• $ x iy ' )0.1 F I as L1VlNs glawF TOTAL Gtt- , F-0 Ll 5 VI gQ - FT. LJI'7 i co yr orz Al 2- 25- L) �r4 SKYL16M 5 .-T o L ice, to x Z.%4)c/0 S L Q2e A MU LT 2-e -F. 9 I n�&T. -2- cm� m V b- mt-T� -1 5- F- M IMAI (4 = 3- M,,#3,04. ) 6 X 510 -2. R% 3 F - (o = 3 to C rr3 I T.)q q T , Al F-i-PX Qnl, W f m-,51 0 1--, so -or, LIV t 4 JW C LAMA W G, A'�IN AREA .., .. P1_.AN 7 Li -) 0-0 !sq. VrT. fY I Cd- 2� Xx -L x SAO 16 t�,. ca LL 57 L A:,?'V.-4Vo 4 8-4 Cl 'lt—)4 I) (y) r Li y /0 -Z 1140 145 fvtOey q2o s x I O"K V.0 G e" T, v t1A OA TOTAL,.. t4 H � PLAW10;- 14 e" - 0 - sQ• FT. �T• . ,3 x = Zy RP p /i �•+r � 1 �o X l = Z'j F wr KYL14)AT5 vC-rl 5cice, ' `t F FoLt.��� f�tJ�v✓ I'L2 r to x I b = t%4 /&r; r o 4�., Tr .. ; LIv/SST, t �y 4.5 Mon, �3 x — 1 S� • • b�N. 3 X � = 3 ��L f • • L,KyUN..• Z x s -1 O • C- NO Yv F• • Z- 5 U ITE•s(o K � = � � S coo TOTAL. (LA-7-ANC,.:_ 911 g.9 % EEQU 1 PMENT coca ec?oA,L) L m,,s HOM s DLDR-SPEcV. WATT HEAMER �� Ca R1 FFl N. R L."C%4 ZO 1-7 mr=-c.H. SPE(fa, +4EATING, 4 A1G L.A .Q vJ NT'A. , CgAS FURNACE 5TU I N PUT 13TU OUTPUT GSM LOW LEAXA.CIS RA FAN WATT ®RW COOLING~ COIL -r KV VE.RIM50 A1RF1.: CONDENSER SSMER/ sER (M1N TO K19:, aTU -.`a Co " 1S SENS. e 1150 \/eP)F=lS0 EER Ric RZI G, . G HAMGE WATER 14SATER � A�-L01.15 P TU H 11.1PVT REcflv�2Y EFFIG. ST'p.N o FsY LO sS ' �NE2C�`t �AGZv1,Z F1RST W2, RA- lV-.lCj H oT H z.o PIPE INS. HVAC DUCT INS%. HYAC vucT TEST TovP. HOUSE mer-% i►�smcGv. _PtEQ'C-. MEc14, SPEC-V. 1y.0/iLO IzEgod _ I ZEQ' O, i",4t�tI�LEsS O '� ZC70, oc�o N� A ►� lA '92 UEF + SO CAI._. IZEQ`D. R-(.n.0 REG?00- x 4 (o mer-VA. SPEGq. $.2NSPF MEGH , Sf'Ectp. REa'm MEcH. SPEC-O. REC,� ca. TIE It4To HOUsu wf 14 REq'O. N1CRHT SUT-FFAGK REQUIREC7 VERIFY 50vrly 09PINANCE (IF AWY) PIZ101Z TO A,Jc SE'r. HVAG EQUIPMENT SIZINGS I SFsG11=1GAmON 131,f vrHiE-LIz.S. �jo' 4 Prior to final inspection an electronically signed and registered copy of the following checked CF2R installation certificates shall be posted and made available to the enforcement agency. For energy features that require HERS field verification, an electronically signed and registered copy of the following checked CF311 verification and diagnostic testing certificates shall be posted and made available to the enforcement agency. Verification Installation Certificate Certificate Document Category Document CF3R (HERS) CF2R Category Description Description Envelope X ENV-01 Non HERS Fenestration/Glazing Envelope X ENV-02 Non HERS Envelope Air Sealing Joints & Openings Envelope X ENV-03 Non HERS Insulation Installation Envelope Roofing - Ventilation X ENV-04 Non HERS Cool Roof or Radiant Barrier If Required) Envelope Building Envelope Air Leakage ENV-20H HERS Blower Door Test ENV- Envelope X 21H-24H HERS Quality Insulation Installation QII Lighting X LTG-01 Non HERS Single Family Lighting Lighting LTG-02 Non HERS Multi -Family Lighting Mechanical HVAC Systems & Ducts X MCH-01 Non HERS Return Air Filter Labeling Mechanical MCH-02 Non HERS Whole House Fan. Mechanical Duct Leakage Test X X MCH-20H HERS Low Leakage Air Handler LLAH Mechanical Duct Location x X MCH-21H HERS Conditioned Space Mechanical Fan Watt Draw Efficacy (FWD) X X MCH-22H HERS .58 Watts/CFM) Mechanical Cooling Coil Airflow (CCA) X X MCH-23H HERS 350 CFM/Ton Mechanical X X MCH-25H HERS Refrigerant Charge Verification Mechanical X X MCH-26H HERS SEER & EER Verification Mechanical Indoor Air Quality & Mechanical Ventilation X X MCH-27H HERS ASHRAE 62.2 Continuous Fan Mechanical Supply Duct Surface Area, MCH-29H HERS R-Value & Buried Ducts Plumbing PLB-01 Non HERS PLB-21H HERS Multi -Family Hot Water Distribution System Plumbing X PLB-02 Non HERS PLB-22H HERS Single Famil Hot Water Distribution System Please coordinate with the subcontractors and HERS rater the importance of having the above checked certificates filled out on time to prevent any hold-ups during final inspection. The Certificate of Occupancy will not be issued until the CF2R & CF3R certificates are reviewed and approved by the enforcement agency. Keep in mind that some of these items need to be inspected by the HERS rater prior to drywall. i Continuous Ventilation Calculation Each whole building ventilation system must meet the minimum CFM required and field verified with diagnostic testing of airflow performance. In addition, the fan must be certified with a maximum sone rating of 1.0 or less. CFA x .01 + 7.5 (# of Bedrooms +1) = Ventilation Rate (Min. CFM @ .25" W.C.) Plan 1(2967) 2967 x .01 + 7.5 (3 + 1) = 29.67 + 30.0 = 59.67 Min. CFM Plan 1X(3271) 3271 x .01 + 7.5 (4 + 1) = 32.71 + 37.5 = 70.21 Min. CFM Plan 2(3314) 3314 x .01 + 7.5 (4 + 1) = 33.14 + 37.5 = 70.64 Min. CFM Plan 3(3475) 3475 x .01 + 7.5 (4 + 1) = 34.75 + 37.5 = 72.25 Min. CFM Plan 4(3818) 3818 x .01 + 7.5 (4 + 1) = 38.18 + 37.5 = 75.68 Min. CFM Plan 5(4154) 4154 x .01 + 7.5 (5 + 1) = 41.54 + 45.0 = 86.54 Min. CFM Plan 6(4529) 4529 x .01 + 7.5 (4 + 1) = 45.29 + 37.5 = 82.79 Min. CFM Plan 7(4700) 4700 x .01 + 7.5 (4 + 1) = 47.00 + 37.5 = 84.50 Min. CFM Plan 8(4820) 4820 x .01 + 7.5 (4 + 1) = 48.20 + 37.5 = 85.70 Min. CFM