Loading...
Codorniz TR 32070 BRES2014-1080 (Plans 1-3, 4-4 & 4-2) 2013 Code Update - Title 24caw/ Title 24 Report CEC Approved 2013 Building Energy Efficiency Standards Job Name Codorniz Plan SF3 Cordia Avenue 52 and Jefferson Street La Quinta, CA 92253 CITY OF LA. Cie. INTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE IVBY Prepared For RJT Homes - Codorniz, LLC Designer Prepared By Dave Bricker Energy Consultant 05082014E EADSENERGY DRIVEN SOLUTIONS INC CAL TITLE 24 REPORTS NCI CERTIFIED AIR BALANCING P. O. Box 6705 LA QuwTA, CA 92248 760-541-9025 FAx 760-775-4723 CHEERS & CALCERTS CERTIFIED HERS RATER DAVEBRICKER@ENERGYDS.NET CABEC CERTIFIED ENERGY ANALYST EDSENERGY DRIVEN SOLUTIONS INC Note to Plan Checker and Inspector Project Name: Codorniz SF-3 A&B Job Number: 05082014B Project Designer: RJT Homes - Codorniz, LLC This project EXCEEDS 2013 Title 24 Standards by: • North Facing 13.8% • East Facing 13.8% m South Facing 12.4% • West Facing 6.3% HERS Measures include: • Verified Building Envelope Air Leakage ® Verified HVAC Fan efficacy • Verified HVAC Refrigerant Charge or Charge Indicator Display Verified HVAC low leakage ducts entirely in conditioned space • Verified HVAC EER of 12.5 • Verified IAQ Fan BUILDING ENERGY ANALYSIS REPORT PROJECT: Codorniz SF-3 A & B Jefferson Street and Avenue 52 La Quinta, CA 92253 Project Designer: RJT Homes - Codorniz, LLC 1245 East University Drive Phoenix, AZ 85034 602-257-1656 Report Prepared by: Dave Bricker Energy Driven Solutions Inc P. O. Box 6705 La Quinta, CA 92248 760.541.9025 Job Number: 05082014B Date: 5/22/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 050820148 I TABLE OF CONTENTS I Cover Page Table of Contents Form CF-1 R Certificate of Compliance Form RMS-1 Residential Measures Summary Form MF-1 R. Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 13 14 17 18 19 21 EnergyPro 6.1 by EnergySoft Job Number: ID: 05082014B User Number: 6168 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-3 A & B Calculation Date/Time: 20:55, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-3 A & B Run 1.xml CF1 R-PRF-NCB-01 Page 1 of 10 GENERAL INFORMATION 01 Project Name Codorniz SF-3 A & B 02 Calculation Description Title 24 Analysis 03 Project Location Jefferson Street and Avenue 52 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-1e (532) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.1 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 1692 15 Number of Zones 2 16 Slab Area (FT2) 950 17 Number of Stories 2 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 Glazing Percentage (%) 19.2% Detailed help on using the CF-1 R Certificate of Compliance Is'avallable via the Internet by either scanning the & code or browsln,g to: http://www.title24energycode.org/t24help/cfl r.aspx 16 r ' ❑ COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below CITY OF LA QUI ETA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE -.BY Registration Number: 214-No095218A-000000000-0000 Registration Date/Time: 2014-09-16 11:16:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:9:06:34 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-3 A & B Calculation Date/Time: 20:55, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-3 A & B Run 1.xml CF1R-PRF-NCB-01 Page 2 of 10 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.70 1.98 -0.28 -16.5% Space Cooling 110.99 93.08 17.91 16.1 % IAQ Ventilation 1.24 1.24 0.00 0.0% Water Heating 14.85 14.69 0.16 1.1% PV Credit ---- 0.00 0.00 ---- North Facing -TOTAL 128.78 110.99 17.79 13.8% Space Heating 1.70 1.18 0.52 30.6% Space Cooling 110.99 93.94 17.05 15.4% IAQ Ventilation 1.24 1.24 0.00 0.0% Water Heating 14.85 14.69 0.16 1.1% PV Credit ---- 0.00 0.00 ---- East Facing - TOTAL 128.78 111.05 17.73 13.8% Space Heating Space Cooling IAQ Ventilation 1 JO-., .�---..,�T 110.99 rr - rr ( (1.24 l 0.87 �-+r-. �96.02� ('° 0.83 14.97 0.00 48.8% 13.5% 0.0% Water Heating `�..�J P t 14.85. .�1.24 �� ,,tr-w ,�"� � 14.69 a 9liCs� 0.16 ° 1.1 /° PV Credit ---- 0.00 0.00 ---- South Facing -TOTAL 128.78 112.82 15.96 12.4% Space Heating 1.70 1.67 0.03 1.8% Space Cooling 110.99 103.12 7.87 7.1% IAQ Ventilation 1.24 1.24 0.00 0.0% Water Heating 14.85 14.69 0.16 1.1% PV Credit ---- 0.00 0.00 ---- West Facing - TOTAL 128.78 120.72 8.06 6.3% Registration Number: 214-N0095218A-000000000-0000 Registration Date/Time: 2014-09-16 11:16:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 CaICERTS ino. Report Generated at: 5/20/2014:9:06:34 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-3 A & B Calculation Description: Title 24 Analysis Calculation Date/Time: 20:55, Tue, May 20, 2014 Input File Name: Codorniz SF-3 A & B Run 1.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation CF1R-PRF-NCB-01 Page 3 of 10 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Codorniz SF-3 A& B 1692 1 3 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 1st Floor Conditioned HVAC Split systeml 950 10 DHW Sys 1 2nd Floor Conditioned t ,, HVACTSplit systeml--,-. -N �-,.742 �� 8 DHW Sys 1 r . r e .. I3Inc. Registration Number: 214-N0095218A-000000000-0000 Registration Date/Time:2014-09-16 11:16:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:9:06:34 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-3 A & B Calculation Date/Time: 20:55, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-3 A & B Run 1.xml CF1R-PRF-NCB-01 Page 4 of 10 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window Area (ft2) Tilt(deg) Exterior Wall front N 1 0x1 1 1st Floor R-13 Wall w/1 EPS 0 Front 110 75 90 Exterior Wall right W 5x9 1st Floor R-13 Wall w/1 EPS 270 Right 45 0 90 Exterior Wall front N 4.5x9 1st Floor R-13 Wall w/1 EPS 0 Front 41 0 90 Exterior Wall right W 5.9x9 1st Floor R-13 Wall w/1 EPS 270 Right 53 15 90 Exterior Wall front N 13.5x9 1st Floor R-13 Wall w/1 EPS 0 Front 122 38 90 Exterior Wall left E 13.5x9 1st Floor R-13 Wall w/1 EPS 90 Left 122 0 90 Exterior Wall rear S 5.5xg 1st Floor R-13 Wall w/1 EPS 180 Back 50 0 90 Exterior Wall right W 2.5x9 1st Floor R-13 Wall w/1 EPS 270 Right 23 0 90 Exterior Wall rear S 4.5x9 1st Floor R-13 Wall w/1 EPS 180 Back 41 0 90 Exterior Wall left E 2.5x9 1st Floor R-13 Wall w/1 EPS 90 Left 23 0 90 Exterior Wall rear S 7x9 1st Floor R-13 Wall w/1 EPS 180 Back 63 0 90 Exterior Wall right W 14.5x9 �stFloor / "' R=13 Wallyw/1:EP�S /2,707 Right 131 18 90 Exterior Wall right W 14.5x11 1st Floorj �r ' <.R-13 Wall w/1�EPS 270' Right 160 40 90 Roof 1st'1716or aFr ! . i ! R-22 Roof Attic rI + JFAF a 208 Interior Surface 38x9 '•-``1,-E&Floor»Garage = jR=13 Wall ----e- - 342 Exterior Wall front N 13xg 2nd Floor R-13 Wall w/1 EPS 0 Front 104 18.1 90 Exterior Wall left E 1.5x9 2nd Floor R-13 Wall w/1 EPS 90 Left 14 0 90 Exterior Wall front N 10.5x9 2nd Floor R-13 Wall w/1 EPS 0 Front 95 8 90 Exterior Wall left E 34.75x9 2nd Floor R-13 Wall w/1 EPS 90 Left 313 63 90 Exterior Wall rear S 14X9 2nd Floor R-13 Wall w/1 EPS 180 Back 126 12.6 90 Exterior Wall right W 1.75x9 2nd Floor R-13 Wall w/1 EPS 270 Right 16 0 90 Exterior Wall rear S 9.5x9 2nd Floor R-13 Wall w/1 EPS 180 Back 86 12.6 90 Exterior Wall right W 34.5x9/2 2nd Floor R-13 Wall w/1 EPS 0 Front 155 25 90 Roof 2 2nd Floor R-22 Roof Attic 742 Floor over garage 2nd Floor»Garage R-19 Floor No Crawlspace 284 Exterior Wall left 20.25x9 Garage Garage Ext Wall 90 Left 182 0 90 Exterior Wall rear 21x9 Garage Garage Ext Wall 180 Back 189 0 90 Exterior Wall right 1x9 Garage Garage Ext Wall 270 Right 9 0 90 Roof 3 Garage R-0 Roof Attic 447 Registration Number: 214-N0095218A-000000000-0000 Registration Date/Time: 2014-09-16 11:16:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:9:06:34 PM CERTIFICATE OF COMPLIANCE'- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-3 A & B Calculation Date/Time: 20:55, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-3 A & B Run 1.xml CF1R-PRF-NCB-01 Page 5 of 10 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 4 0.1 0.85 No No WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height 00 Width(ft ) Multiplie r Area (ft) U- factor SHG C Exterior Shading Window7680 SLDR 7 Window Exterior Wall front N 1 0x1 1 (Front-0) ---- ---- 1 60.0 0.34 0.32 Window 7620 FG 6 Window Exterior Wall front N 1 0x1 1 (Front-0) ---- --- 1 15.0 0.32 0.34 Window 2660SH 8 Window Exterior Wall right W 5.9x9 (Right-270) ---- ---- 1 15.0 0.35 0.32 Window 2) 2660SH 9, 10 Window Exterior Wall front N 13.5x9 (Front-0) ---- ---- 1 30.0 0.35 0.32 Window 2040SH 11 Window Exterior Wall front N 13.5x9 (Front-0) ---- --- 1 8.0 0.35 0.32 Window 3060SH 1 Window y ExterioryWall- right::W-14:5x9 (Right=270)p-■ f 1 18.0 0.35 0.32 Window 2660SH 2 Window `' Exterior Wall right W ,14.5x11 (Right=270) '` = - --- 1 15.0 0.35 0.32 Window 2620FG 3 Window s/ /` Exterior Wall right* 14.5x11t'(Right-270) y --- { tr 1 5.0 0.32 0.34 Window 2660SH 4 Window ``+ `✓ rt --''Exterior Wall right W 14:5zT1 (Rig6t-270)`' � ' +[X�L`-G 1 15.0 0.35 0.32 Window 2620FG 5 Window Exterior Wall right W 14.5x11 (Right-270) ---- -- 1 5.0 0.32 0.34 Window 2868FR 14 Window Exterior Wall front N 13x9 (Front-0) ---- ---- 1 18.1 0.34 0.32 Window 2040SH 15 Window Exterior Wall front N 10.5x9 (Front-0) ---- --- 1 8.0 0.35 0.32 Window 2040SH 16 Window Exterior Wall left E 34.75x9 (Left-90) ---- ---- 1 8.0 0.35 0.32 Window 2) 2650SH 17,18 Window Exterior Wall left E 34.75x9 (Left-90) ---- ---- 1 25.0 0.35 0.32 Window 2) 3050SH 19,20 Window Exterior Wall left E 34.75x9 (Left-90) ---- ---- 1 30.0 0.35 0.32 Window 2626FG �1 Window Exterior Wall rear S 14X9 (Back-160) _ --- -- 1 6.3 0.32 0.34 Window 2626FG 22 Window Exterior Wall rear S 14X9 (Back-180) ---- ---- 1 6.3 0.32 0.34 Window 2626FG 23 Window Exterior Wall rear S 9.5x9 (Back-180) ---- ---- 1 6.3 0.32 0.34 Window 2626FG 24 Window Exterior Wall rear S 9.5x9 (Back-180) ---- --- 1 6.3 0.32 0.34 Window 2) 2650SH 12,13 Window Exterior Wall right W 34.5x9/2 (Front-0) ---- ---- 1 25.0 0.35 0.32 Registration Number: 214-N0095218A-000000000-0000 Registration Date/Time: 2014-09-16 11:16:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:9:06:34 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-3 A & B Calculation Date/Time: 20:55, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-3 A & B Run 1.xml CF1 R-PRF-NCB-01 Page 6 of 10 DOORS 01 02 03 04 Name Side of Building Area (ft) U-factor Door 3080 Exterior Wall front N 4.5x9 24.0 1.00 Door 2868 Interior Surface 38x9 17.8 1.00 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor. - no attic floor - Cavity: - no insulation - R-0 Roof Attic Ceilings (below attic) 11V /ood framed Ceil� . '2x4 24^in. O C ` 1 Sheathinglnsulation - no sheathing/insul. - Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - ;'-.nCI r'"_'I eta ,y..• ! �- IJG !Ji`f! ' Cavity: R 13 _ _C .L� Sheathing/Insulation: - no sheathing/insul. - R-13 Wall w/1 EPS Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 Exterior Finish: R4 Synthetic Stucco Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: R 13 Sheathing/Insulation: - no sheathing/insul. - R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 Other Side Flnish: Gypsum Board Attic Floor: - no attic floor - Cavity: R 22 Sheathinglnsulation - no sheathing/insul. - R-22 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 22 Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: - no insulation - Sheathing/Insulation: - no sheathing/insul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. Exterior Finish: 3 Coat Stucco Registration Number: 214-N0095218A-000000000-0000 Registration Date/Time: 2014-09-16 11:16:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:9:06:34 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-3 A & B Calculation Description: Title 24 Analysis Calculation Date/Time: 20:55, Tue, May 20, 2014 Input File Name: Codorniz SF-3 A & B Run 1.xml CF1R-PRF-NCB-01 Page 7 of 10 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Covered Slab 1st Floor 348 51 None 0.8 No Exposed Slab 1st Floor 602 67 None 0.8 No Slab -on -Grade Garage 447 0.1 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED REQUIRED 4.4 WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type - J Number of Heaters Solar Fraction (%) DHW Sys 1 fr' _ ' �/, Pipe Insulation, All Lines `. 1 0.0% 1 '0" / f i i h f 1.- r- 1 , c, WATER HEATERS / ! ` ftl `!v- 1 f / f` J \ J A ) : _ 7,"I �f 1" Y -, 01 02 03 - 04 -05 - 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.575 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a n/a Registration Number: 214-N0095218A-000000000-0000 Registration Date/Time: 2014-09-16 11:16:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:9:06:34 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-NCB-01 Project Name: Codorniz SF-3 A & B Calculation Description: Title 24 Analysis Calculation Date/Time: 20:55, Tue, May 20, 2014 Input File Name: Codorniz SF-3 A & B Run 1.xml Page 8 of 10 HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC Split system1 Other Heating and Cooling System Heating Component 1 Yes Cooling Yes Air Distribution HVAC Fan 1 1692 Component 1 System 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 92 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 Name Sy tem""T"=. /�"'� Efficiency EER k SEER HERS Verification Cooling Component 1 SplitAirCond -/Split air conditioning system '- rt: 12.5 , 15 Cooling Component 1-hers-cool 1 1I1 {./)..• J r- '1 A 1 1 J 5 1 I ! .: fc.- If I'IF I r. HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Verified low -leakage ducts Sealed and tested 8 Conditioned Zone Conditioned Zone None Air Distribution entirely in conditioned space System 1-hers-dist Registration Number: 214-NO09521BA-000000000-0000 Registration Date/Time: 2014-09-16 11:16:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:9:06:34 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-3 A & B Calculation Date/Time: 20:55, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-3 A & B Run 1.xml CF1R-PRF-NCB-01 Page 9 of 10 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required 6.0 Required Not Required Not Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 r a y IAQ (Indoor Air Quality) FANS 01 1 r.I/�/r j ,I 4- 02 / 03 t� 04 05 Name ,""` ' "` IAQ CFM — " ' '-" ` IAQ Fan Type )l Ik Recovery Effectiveness(%) HERS Verification IAQ Fan 47 Exhaust 0 Required COOLING VENTILATION NONE Registration Number: 214-N0095218A-000000000-0000 Registration Date/Time: 2014-09-16 11:16:35 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 Report Generated at: 5/20/2014:9:06:34 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-3 A & B Calculation Description: Title 24 Analysis Calculation Date/Time: 20:55, Tue, May 20, 2014 Input File Name: Codorniz SF-3 A & B Run 1.xml CF1 R-PRF-NCB-01 Page 10 of 10 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: David Bricker V'Wa0Z4%&'4' Company: Signature Date: Energy Driven Solutions, Inc. 2014-09-16 11:12:05 Address: CEA/HERS Certification Identification (If applicable): PO Box 6705 R08-06-207 City/State/Zip: Phone: La Quinta, CA 92248 760 541 9025 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on,this,Certificate of, Compliance are -consistent -with the information provided on other applicable compliance documents, worksheets, calculations, plans and'specifications subrriitted,to the enforcement'agency for, approval with'this building permit application. Responsible Designer Name: %J -, '�` ResponsibleD'signer Signature: C�Z /1{f* Chad Meyer a yer l - i' .J�i� 1 o _ 4� - Company: Date Signed: RJT Homes 2014-09-16 11:16:35 Address: License: PO Box 810 NA City/State/Zip: Phone: La Quinta, CA 92253 760-564-6555 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-No095218A-000000000-0000 Registration Date/Time: 2014-09-16 11:16:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:9:06:34 PM RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Codorniz SF-3 A & 8 Building Type 0 Single Family ❑ Addition Alone 10 Multi Family ❑ Existing+ Addition/Alteration Date 512212014 Project Address Jefferson Street and Avenue 52 La Quint California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1, 692 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Wall Wood Framed R 13 1,544 Rigid=R-4.0 New Door Opaque Door - no insulation 24 New Demising Wood Framed R 13 324 New Slab Unheated Slab -on -Grade - no insulation 950 Perim = 118' New Roof Wood Framed Attic . R 22 950 New Demising Wood Framed w/o Crawl Space no insulation 458 New Demising Wood Framed w/o Crawl Space R 19 284 New FENESTRATION I Total Area: 325 Glazing Percentage: 19•2 % New/Altered Average U-Factor: Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades 0.34 Status Front (N) 78.1 0.340 0.32 none none Bug Screen New Front (N) 15.0 0.320 0.34 none none Bug Screen New Right (W) 63.0 0.350 0.32 none none Bug Screen New Front (N) 71.0 0.350 0.32 none none Bug Screen New Right (W) 10.0 0.320 0.34 none none Bug Screen New Left (E) 63.0 0.350 0.32 none none Bug Screen New Rear (S) 25.2 0.320 0.34 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 92% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status HVAC Split system Ducted Ducted Conditioned 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.58 All Pipes Ins New Ener Pro 6.1 by EnerqZSoft User Number: 6168 RunCode: 2014-05-22T11:20:16 ID: 05082014E Pa e 13 of 24 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R L7 Project Name Codorniz SF-3 A & 8 Date 512212014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (") below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with tans. Building Envelope Measures: 110.E a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF-1 R Forma * 150.0(a): Minimum R-30 (R-19 for Additions/Alterations) insulation in wood -frame ceiling or equivalent U-factor. 150.0 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§ 150.0(c): Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 or equivalent U-factor. *§ 1 50.0(d): Minimum R-19 insulation in raised wood -frame floor or equivalent U-factor. 1 50.0(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 erm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 e 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the buildin , are prohibited. Space Conditioning, Water Pleating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2c . §150.0(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150.00)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150.0-B. §150.0(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150.0-B and Equation 150.0-A. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. 150.0 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150.0 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 05082014E Page 14 of 24 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Codomiz SF-3 A & B 512212014 §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1 /4 inch, the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined .or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0 m 7: Exhaust fan systems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150.0 m 10: Flexible ducts cannot have porous inner cores. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating stems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §150.0(p): Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150.0(p). Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. 150.0(k)1C: The wattage of permanent!y installed luminaires shall be determined asspecified by §130.0(c). §150.0(k)1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. 150.0 '.<)1 F: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable. requirements of 150.0 k . 150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one nigh efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 05082014E Page 15 of 24 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 WAR Project Name Codomiz SF-3 A & 8 Date 512212014 §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 050820148 Page 16 of 24 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Codorniz SF-3 A & B Date 5/22/2014 System Name HVAC Split system Floor Area 1,692 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,067 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 73,600 22,702 1,919 505 19,901 Total Output (Btuh) 73,600 0 Output (iBtuh/s ft) 43.5 0 0 Cooling System 01. 0 Output per System 46,000 0 0 0 0 Total Output (Btuh) 46,000 2,233 1,919 -2,233 Total Output (Tons) 3.8 0 0 Total Output (Btuh/s ft) I 27.2 Total Output (s ft/Ton) I 441.4 24,935 17,667 Air System CFM per System 1,500 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,500 Carrier Corp. CA16NA048""'A 32,675 6,452 73,600 Airflow (cfm/sgft) 0.89 Airflow (cfm/Ton) 391.3 Outside Air (%) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 32,675 6,452 73,600 Outside Air (cfm/sqft) I 0.00 Note: values above iven at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 68 OF Outside Air 0 cfm Supply Fan 1,500 cfm 68 OF -4— 69 OF 105 OF Heating Coil T ---- ----- fl 105 OF Room 13 68 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 112/78OF 75/62OF 76/62OF 55/54OF Outside Air 0 cfm Supply Fan Cooling Coil 55 / 54 OF 1,500 cfm 47.4 %OOM 75 / 62 OF 75 / 62 OF EnergyPro 6.1 by EnergySoft User Number. 6168 RunCode: 2014-05-22T11:20:16 ID: 05082014E Page 17 of 24 ROOM LOAD SUMMARY Project Name Date Codomiz SF-3 A & 8 1 512212014 System Name Floor Area HVAC Split system 1,692 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible 1st Floor 1st Floor 1 582 1Z395 1,078 582 12,395 1,078 323 12,726 2nd Floor 2nd Floor 1 484 10,3071 842 484 10,3071 842 182 7,175 PAGE TOTAL TOTAL * 1,067 22,702 1,9191 505 19,901 1,067 2Z702 1,919 505 19,901 Total includes ventilation load for zonal systems. Ener Pro 6.1 by EnergySqft User Number.- 6168 RunCode: 2014-05-22T11:20:16 /D: 05082014B Page 18 of 24 ROOM HEATING PEAK LOADS Project Name Codorniz SF-3 A & 8 Date 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 1st Floor Floor Area 950.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X OT'F c _ = c _ = = = _ = = = = = — — — = = = = = - — = — = — _ = 42 Btu/hr R-13 Wall w/1 " EPS 774.0 0.0724 42 2,355 Alpine A172 Sldg Glass/Patio Door 60.0 0.3400 42 857 Alpine A770 Picture/Fixed 25.0 0.3200 42 336 Wood Door 24.0 1.4500 42 1,462 Alpine A571 Single Hung 101.0 0.3500 42 1,485 *R-13 Wall 342.0 0.1020 18 628 Slab -On -Grade perim = 118.0 0.7300 42 3,618 R-22 Roof Attic 208.0 0.0410 42 358 Items shown with an asterisk (*) denote conduction Infiltration.[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 950 X Area another room 10.00 X 0.235 Height ACH Page Total / 60 ] X AT 11,098 _ 1,660 TOTAL DOURLY HEAT LOSS FOR ROOM 12,726 EnergyPro 6.1 by EnergySoft User Number: 6168 RunCode: 2014-05-22T11:20:16 ID: 05082014E Page 19 of 24 ROOM HEATING PEAK LOADS Project Name Codorniz SF-3 A & 8 Date 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Blame 2nd Floor Floor ,area 742.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F _ . — _ _ _ = — = = = = = = = = — = = = = = = = = = = — _ = 42 Btu/hr R-13 Wall N11 " EPS 769.7 0.0724 42 2,342 Alpine A172 Sldg Glass/Patio Door 18.1 0.3400 42 258 Alpine A571 Single Hung 96.0 0.3500 42 1,411 Alpine A770 Picture/Fixed 25.2 0.3200 42 339 R-22 Roof Attic 742.0 0.0410 42 .1,278 *R-0 Floor No Crawlspace 458.0 0.2380 0 0 *R-19 Floor No Crawlspace 284.0 0.0490 18 250 Items shown with an asterisk (*) denote conduction infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 742 X Area another room 8.00 X 0.293 Height ACH Page Total / 60 ] X AT 5,878 = 1,297 TOTAL HOURLY HEAT LOSS FOR ROOM 7,175 EnergyPro 6.1 by EnergySoft User Number: 6168 Run Code: 2014-05-22T11:20:16 ID: 05082014B Page 20 of 24 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codorniz SF-3 A & B 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 1st Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 950.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-13 Wall w/1 " EPS (N) 136.0 X 0.0724 X 23.0 = 227 R-13 Wall w/1 " EPS (W) 339.0 . X 0.0724 X 33.0 = 810 Wood Door (N) 24.0 X 1.4500 X 23.0 _ 800 R-13 Wall w/1 " EPS (E) 145.0 X 0.0724 X 33.0 = 347 *R-13 Wall 342.0 X 0.1020 X 25.0 = 872 R-13 Wall w/1 ° EPS (S) 154.0 X 0.0724 X 26.0 _ 290 R-22 Roof Attic (N) 208.0 X 0.0410 X 56.0 = 478 X X = X X = Page Total 3,824 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window7680 SLDR 7 (N) 0.0 X 18.7 + 60.0 X 18.7 = 1,120 Window 7620 FG 6 (N) 0.0 X 19.0 + 15.0 X 19.0 = 285 Window 2660SH 8 (W) 0.0 X 18.9 + 15.0 X 37.9 = 568 Window 2) 2660SH 9, 10 (N) 0.0 X 18.9 + 30.0 X 18.9 = 566 Window 2040SH 11 (N) 0.0 X 18.9 + 8.0 X 18.9 = 151 Window 3060SH 1 (W) 0.0 X 18.9 + 18.0 X 37.9 = 682 Window 2660SH 2 (W) 0.6 X 18.9 + 15.0 X 37.9 = 568 Window 2620FG 3 (W) 0.0 X 19.0 + 5.0 X 39.2 = 196 Window 2660SH 4 (W) 0.0 X 18.9 + 15.0 X F 37.9 = 568 Page Total 4,705 Internal Gain Btu/hr Occupants 2 9 Occupants X 245 Btuh/occ. = 698 Equipment 950 Floor Area X 0.50 w/sqf{ Infiltration: 1.064 X 0.89 X 39.72 X 37 = 1,396 Air Sensible CFM ELA 4T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,395 Latent Gain Btu/hr Occupants 2 9 Occupants X 155 gtuh/occ. = 442 Infiltration: 4, 771 x 0.89 X 39.72 X 0.00376 = 636 Air Sensib!e CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 442 Ener Pro 6.1 b Ener Soft User Number: 6168 RunCode: 2014-05-22T11:20:16 ID: 05082014E Page 21 of 24 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codomiz SF-3 A & B 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 1st Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 950.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X - X X = X X = X X - X X - X X - X X = X X = X X _. Page Total 0 Items shown with an asterisk (*) denote conduction through an interior surface to another room. A. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 2620FG 5 (W) 0.0 X 19.0 + 5.0 X 39.2 _ 196 X + X = X + X = X + X = X + X X + X = X + X = X + X — X + X = Page Total 196 Internal Gain Btu/hr Occupants 2.9 Occupants X 245 Btuh/occ. = 698 Equipment 950 Floor Area X 0.50 w/sgft _. 1,621 Infiltration: 1.064 X 0.89 X 39.72 X 37 = 1,396 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,395 Latent Gain Btu/hr Occupants 2.9 Occupants X 155 Btuh/occ. _ 442 Infiltration: 4,771 x 0.89 X 39.72 X 0.00376 = 636 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 442 EnergyPro 6.1 by Ener Soft User Number: 6168 RunCode: 2014-05-22T11:20:16 ID: 05082014E Page 22 of 24 12 r, e"a RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codorniz SF-3 A & B 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 742.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF, Outdoor Daily Range: 34 OF _Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-13 Wall w/1 " EPS (N) 302.9 X 0.0724 X 23; 0 . c 505 R-13 Wall w11 " EPS (E) 264.0 X 0.0724 X 33.0 = 631 R-13 Wall w11 " EPS (S) 186.8 X 0.0724 X 26.0 = 352 R-13 Wall w11 " EPS I (W) 16.0 X 0.0724 X 33.0 = 38 R-22 Roof Attic (SW) 742.0 X 0.0410 X 56.0 = 1,704 *R-0 Floor No Crawlspace 458.0 X 0.2380 X 0.0 = 0 *R-19 Floor No Crawlspace 284.0 X 0.0490 X 25.0 = 348 X X X X = Page Total 3,577 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 2868FR 14 (N) 0.0 X 18.7 + 18.1 X 18.7 _ 338 Window 2040SH 15 (N) 0.0 X 18.9 + 8.0 X 18.9 = 151 Window 2040SH 16 (E) 0.0 X 18.9 + 8.0 X 37.9 = 303 Window 2) 2650SH 17, 18 (E) 0.0 X 18.9 + 25.0 X 37.9 = 947 Window 2) 3050SH 19, 20 (E) 0.0 X 18.9 + 30.0 X 37.9 = 1,136 Window 2626FG 21 (S) 0.0 X 19.0 + 6.3 X 19.1 = 120 Window 2626FG 22 ( (S) 0.0 X 19.0 + 6.3 X 19.1 = 120 Window 2626FG 23 (S) 0.0 X 19.0 + 6.3 X 19.1 = 120 Window 2626FG 24 (S) 0.0 X 19.0 + 6.3 X 19.1 = 120 Page Total 3,356 Internal Gain Btu/hr Occupants 2.2 Occupants X 245 Btuh/occ. = 545 Equipment 742 Floor Area X 0.50 W/sgft Infiltration: 1.064 X 0.89 X 31.02 X 37 = 1,090 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,307 Latent Gain Btu/hr Occupants 2.2 Occupants X 155 Btuh/occ. = 345 Infiltration: 4,771 X 0.89 X 31.02 X 0.00376 - 497 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 345 EnergvPro 6.1 b Ener 4 Soft User Number: 6168 RunCode: 2014-05-22T11:20:16 ID: 050820148 -Page 23 of 24 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codomiz SF-3 A & B 512212014 ROOM INFORMATION DESIGN CONDITIONS .Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 742.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD� Btu/hr X X = X X = X X = X X = X X - X X = X X = X X - X X _ Page Total 0 Items shown with an asterisk (*) denote conductior�tdrough an interior surface to another room. 1' Cooling Load Temperature Difference.(CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 2) 2650SH 12, 13 (N) 0.0 X 18.9 + 25.0 X 18.9 = 472 X + X = X + X = X + X = X + X - IX + X = X + X = X + X = X + X = Page Total 472 Internal Gain Btu/hr Occupants 2 2 Occupants X 245 Btuh/occ.PPCI 545 Equipment 742 Floor Area X 0.50 sIq l- w%sgf41 1,266 LU Infiltration: 1.064 X0.89. X 31.02 X 37 = �� ,- � °01,090 _ , Sensible CFM ELA AT L _,UJAir (3!Li ->LL'* TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM I _J UJ rj5 in 1 10,307 �e�Z 06 I Latent Gain (:j 0 UO Btu/hr Occupants 2.2 Occupants X 155 Ir — 0 P Btu 345 O Infiltration: 4,771 X 0.89 X 31.02 X 0.00376 = m Q 497 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 345 EnerqyPro 6.1 by Ener Soft User Number: 6168 RunCode: 2014-05-22T11:20:16 ID: 05082014E Pa a 24 of 24 J OFJ::�jC67 Title 24 Report CEC Approved 2013 Building Energy Efficiency Standards Job Name Codorniz Plan SF-2 Sage Avenue 52 and Jefferson Street La Quinta, CA 92253 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATESW+--BY Prepared For RJT Homes - Codorniz, LLC Designer Prepared By Dave Bricker Energy Consultant 05082014A LEDsENERGY DRIVEN SOLUTIONS INC CAL TITLE 24 REPORTS NCI CERTIFIED AIR BALANCING ' P. O. Box 6705 LA QUINTA, CA 92248 760-541-9025 FAx 760-775-4723 CHEERS & CALCERTS CERTIFIED HERS RATER DAVEBRICKER@ENERGYDS.NET CABEC CERTIFIED ENERGY ANALYST EDSENERGY DRIVEN SOLUTIONS INC Note to Plan Checker and Inspector Project Name: Codorniz SF-2 Job Number: 05082014A Project Designer: RJT Homes - Codorniz, LLC This project EXCEEDS 2013 Title 24 Standards by: • North Facing 20.6% • East Facing 17.1 % • South Facing 19.5% • West Facing 5.0% HERS Measures include: • Verified Building Envelope Air Leakage • Verified HVAC Fan efficacy • Verified HVAC Refrigerant Charge or Charge Indicator Display • Verified HVAC low leakage ducts entirely in conditioned space • Verified HVAC EER of 12.5 • Verified IAQ Fan BUILDING ENERGY ANALYSIS REPORT PROJECT: Codorniz SF-2 A Jefferson Street and Avenue 52 La Quinta, CA 92253 Project Designer: RJT Homes - Codorniz, LLC 1245 East University Drive Phoenix, AZ 85034 602-257-1656 Report Prepared by: Dave Bricker Energy Driven Solutions Inc P. O. Box 6705 La Quinta, CA 92248 760.541.9025 Job Number: 05082014A Date: 5/22/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 6.1 by Energ Soft User Number: 6168 ID: 05082014A CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-NCB-01 Project Name: Codorniz SF-2 A Calculation Description: Title 24 Analysis Calculation Date/Time: 20:39, Tue, May 20, 2014 Input File Name: Codorniz SF-2A Run 1.xml Page 1 of 12 GENERAL INFORMATION 01 Project Name Codorniz SF-2 A 02 Calculation Description Title 24 Analysis 03 Project Location Jefferson Street and Avenue 52 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-1e (532) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.1 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 1504 15 Number of Zones 2 16 Slab Area (FT2) 722 17 Number of Stories 2 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 Glazing Percentage (%) 23.3% Detailed help on using the CF-1 R Certiflcate�of Compliances ailabI via the Internet by either scanning the QR code or browsing to: http://www.title24ener4ycode.org/t24help/cfl r.aspx ■ ❑ COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below CITY OF LA QUINTA BUILDING & SAF PPRp DEPT. 4OD R CONSTRUCT Ot DATE ----�._8Y I Registration Number: 214-N0093964A-000000000-0000 Registration Date/Time: 2014-09-15 13:46:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:52:07 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-2 A Calculation Date/Time: 20:39, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-2A Run 1.xml CF1R-PRF-NCB-01 Page 2 of 12 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 2.45 2.57 -0.12 -4.9% Space Cooling 122.05 92.79 29.26 24.0% IAQ Ventilation 1.34 1.34 0.00 0.0% Water Heating 16.24 16.08 0.16 1.0% PV Credit ---- 0.00 0.00 ---- North Facing -TOTAL 142.08 112.78 29.30 20.6% Space Heating 2.45 1.51 0.94 38.4% Space Cooling 122.05 98.80 23.25 19.0% IAQ Ventilation 1.34 1.34 0.00 0.0% Water Heating 16.24 16.08 0.16 1.0% PV Credit ---- 0.00 0.00 ---- East Facing -TOTAL 142.08 117.73 24.35 17.1% Space Heating Space Cooling 2.45 -- �1'22A5 0.49 �+ 96.40 1.96 25.65 80.0% 21.0% IAQ Ventilation �`J , 1:34 1.34 ti 0.00 0.0% Water Heating 16.24 . 0.16 1.0% ,, _6.08 PV Credit ---- 0.00 0.00 --- South Facing - TOTAL 142.08 114.31 27.77 19.5% Space Heating 2.45 1.39 1.06 43.3% Space Cooling 122.05 116.15 5.90 4.8% IAQ Ventilation 1.34 1.34 0.00 0.0% Water Heating 16.24 16.08 0.16 1.0% PV Credit ---- 0.00 0.00 ---- West Facing - TOTAL 142.08 134.96 7.12 5.0% Registration Number: 214-N0093964A-000000000-0000 Registration Date/Time: 2014-09-15 13:46:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:52:07 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-NCB-01 Project Name: Codorniz SF-2 A Calculation Description: Title 24 Analysis Calculation Date/Time: 20:39, Tue, May 20, 2014 Input File Name: Codorniz SF-2A Run 1.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation • Window overhangs and/or fins Page 3 of 12 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Codorniz SF-2 A 1504 1 3 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 1st Floor Conditioned HVAC Split system_1 722 11 DHW Sys 1 2nd Floor fCoriditioned F if HVAC Split system1 _ 782j 8 DHW Sys 1 Registration Number: 214-No093964A-000000000-0000 Registration Date/Time:2014-09-15 13:46:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:52:07 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-2 A Calculation Date/Time: 20:39, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-2A Run 1.xml CF1 R-PRF-NCB-01 Page 4 of 12 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window Area (ft) Tilt(deg) Exterior Wall front N 13x9 1st Floor R-15 Wall w/2 EPS 0 Front 117 72 90 Exterior Wall right 5x9 1st Floor R-15 Wall w/2 EPS 270 Right 45 15 90 Exterior Wall front N 15.5x9 1st Floor R-15 Wall w/2 EPS 0 Front 140 45 90 Exterior Wall left E 8.5x9 1st Floor R-15 Wall w/2 EPS 0 Front 77 15 90 Exterior Wall front N 5.5x9 1st Floor R-15 Wall w/2 EPS 0 Front 50 0 90 Exterior Wall left E 11x9 1st Floor R-15 Wall w/2 EPS 90 Left 99 25 90 Exterior Wall rear S 13x8 1st Floor R-15 Wall w/2 EPS 180 Back 104 12.5 90 Exterior Wall right W 27x9 1st Floor R-15 Wall w/2 EPS 270 Right 243 33 90 Roof 1st Floor R-22 Roof Attic 44 Interior Surface 38x9 1 st Floor»Garage R-15 Wall 342 Exterior Wall front N 13.25x9 2nd Floor R-15 Wall w/2 EPS 0 Front 119 24 90 Exterior Wall left E 10.7x8 2nd Floor y., —. +�- R-15 Wall.w/2 EPS -71,90,�, Left 86 0 90 Exterior Wall front N 15.2x5 2nd Floor. / f R-115 Wall w/2;EPS 0 Front 76 15 90 Exterior Wall right W 1.5x9 2nd Floor J f 1 �" ` R-15 Wall w/2 EPS /Frorif) 14 0 90 Exterior Wall front N 5.5x9 2 - ``�2nd Flo6r'- ^ = R=15 Wall w/2 EPS 'Fr`ont 50 18.09 90 Exterior Wall left E 18x9 2nd Floor R-15 Wall w/2 EPS 0 Front 162 12.5 90 Exterior Wall rear S 6.5x9 2nd Floor R-15 Wall w/2 EPS 0 Front 59 15 90 Exterior Wall left E 8x9 2nd Floor R-15 Wall w/2 EPS 90 Left 72 0 90 Exterior Wall rear S 14.5x9 2nd Floor R-15 Wall w/2 EPS 180 Back 131 8 90 Exterior Wall right W 8x9 2nd Floor R-15 Wall w/2 EPS 180 Back 72 0 90 Exterior Wall rear S 13x9 2nd Floor R-15 Wall w/2 EPS 270 Right 117 15 90 Exterior Wall right W 27x9 2 2nd Floor R-15 Wall w/2 EPS 0 Front 243 25.2 90 • Roof 2 2nd Floor • R-22 Roof Attic 782 Floor over garage 2nd Floor»Garage R-19 Floor No Crawlspace 410 Exterior Wall left 19.5x9 Garage Garage Ext Wall 90 Left 176 0 90 Exterior Wall front 21x9 Garage Garage Ext Wall 180 Back 189 0 90 Exterior Wall right 8x9 Garage Garage Ext Wall 270 Right 72 0 90 Roof 3 Garage R-0 Roof Attic 462 Registration Number: 214-N0093964A-000000000-0000 Registration Date/Time: 2014-09-1513:46:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:52:07 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R-PRF-NCB-01 Project Name: Codorniz SF-2 A Calculation Description: Title 24 Analysis Calculation Date/Time: 20:39, Tue, May 20, 2014 Input File Name: Codorniz SF-2A Run 1.xml Page 5 of 12 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 4 0.1 0.85 No No f s^f � 7.-e— o- Registration Number: 214-N0093964A-000000000-0000 Registration Date/Time: 2014-09-15 13:46:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:52:07 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-2 A Calculation Date/Time: 20:39, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-2A Run 1.xml CF1R-PRF-NCB-01 Page 6 of 12 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height (ft) Width(ft ) Multiplie r Area (ft) U- factor SHG C Exterior Shading Window 9080SLDR 5 Window Exterior Wall front N 13x9 (Front-0) ---- --- 1 72.0 0.35 0.32 Window 2660SH 6 Window Exterior Wall right 5x9 (Right-270) ---- ---- 1 15.0 0.35 0.32 Window 2660SH 7 Window Exterior Wall front N 15.5x9 (Front-0) ---- ---- 1 15.0 0.35 0.32 Window 2660SH 8 Window Exterior Wall front N 15.5x9 (Front-0) ---- ---- 1 15.0 0.35 0.32 Window 260SH 9 Window Exterior Wall front N 15.5x9 (Front-0) --- -- 1 15.0 0.35 0.32 Window 2660SH 10 Window Exterior Wall left E 8.5x9 (Front-0) ---- ---- 1 15.0 0.35 0.32 Window 2660SH 11 Window Exterior Wall left E 11x9 (Left-90) ---- ---- 1 15.0 0.35 0.32 Window 2640SH 12 Window Exterior Wall left E 11x9 (Left-90) --- --- 1 10.0 0.35 0.32 Window 2650SH 13 Window Exterior Wall rear S 13x8 (Back-180) ---- ---- 1 12.5 0.35 0.32 Window 3) 8 GB 1 Window Exterior Wall right W 27x9 (Right-270) ---- ---- 1 1.5 0.64 0.66 Window 3) 8 GB 2 Window Exterior Wall right W 27x9 (Right-270) ---- --- 1 1.5 0.64 0.66 Window 2) 2660 SH 3, 4 Window �f' ExtenorWall right 27x9 (R,ight2:70) � � ---- ---- 1 30.0 0.35 0.32 Door 3068FR 18 Window t`� Exterior Wal[front N 13.25x9 (Front-0) 1 - -- , . "' , = 1 24.0 0.34 0.32 Window 2620FG 19 Window ` '`` Extetior'Wall'froht N`15:2x5(Frorit-0)' "` ---"A d - " ' `-'J"O 1 5.0 0.32 0.34 Window 2620FG 20 Window Exterior Wall front N 15.2x5 (Front-0) --- ---- 1 5.0 0.32 0.34 Window 2620FG 21 Window Exterior Wall front N 15.2x5 (Front-0) ---- --- 1 5.0 0.32 0.34 Door 2868FR 22 Window Exterior Wall front N 5.5x9 2 (Front-0) 6.7 2.7 1 18.1 0.34 0.32 Window 2650SH 23 Window Exterior Wall left E 18x9 (Front-0) ---- ---- 1 12.5 0.35 0.32 Window 3050SH 24 Window Exterior Wall rear S 6.5x9 (Front-0) ---- ---- 1 15.0 0.35 0.32 Window 2040SH 25 Window Exterior Wall rear S 14.5x9 (Back-180) ---- ---- 1 8.0 0.35 0.32 Window 3050SH 26 Window Exterior Wall rear S 13x9 (Right-270) ---- - 1 15.0 0.35 0.32 Window 2626FG 14 Window Exterior Wall right W 27x92 (Front-0) --- --- 1 6.3 0.32' 0.34 Window 2626FG 15 Window Exterior Wall right W 27x9 2 (Front-0) --- --- 1 6.3 0.32 0.34 Window 2626FG 16 Window Exterior Wall right W 27x9 2 (Front-0) ---- ---- 1 6.3 0.32 0.34 Window 2626FG 17 Window Exterior Wall right W 27x9 2 (Front-0) ---- ---- 1 6.3 0.32 0.34 Registration Number: 214-N0093964A-000000000-0000 Registration Date/Time: 2014-09-15 13:46:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:52:07 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-2 A Calculation Date/Time: 20:39, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-2A Run 1.xml CFI R-PRF-NCB-01 Page 7 of 12 DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door 3080 Exterior Wall front N 5.5x9 24.0 1.00 Door 2868 Interior Surface 38x9 17.3 1.00 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 1 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up Door 2868FR 22 5 0.1 2 2 0 0 0 0 0 0 0 0 0 G Registration Number: 214-No093964A-000000000-0000 Registration Date/Time: 2014-09-1513:46:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:52:07 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-2 A Calculation Date/Time: 20:39, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-2A Run 1.xml CF1 R-PRF-NCB-01 Page 8 of 12 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic floor - Cavity: - no insulation - Sheathinglnsulation - no sheathing/insul. - R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: R 15 Sheathing/Insulation: R8 Sheathing R-15 Wall w/2 EPS Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 Exterior Finish: Wood Siding/sheathing/decking Inside Finish: Gypsum Board i ir. Sheathing/Insulation: - no sheathing/insul. - Cavity: R 15 Sheathing/Insulation: - no sheathing/insul. - d R-15 Wall Interior Walls Pood Framed Wall,l 2z4 @ 16 in/O.C. R 15g �, Other Side Finish: Gypsum Board �., . - .: _�'.: L `°.• .c� l �;+'"` �G'Srr • Attic Floor: - no attic floor - Cavity. R 22 SheathingInsulation - no sheathing/insul. - R-22 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 22 Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: - no insulation - Sheathing/Insulation: - no sheathing/insul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. Exterior Finish: 3 Coat Stucco SLAB FLOORS • 01 02 '03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab -on -Grade exposed 1st Floor 474 74 None 0.8 No Slab -on -Grade covered 1st Floor 248 32 None 0.8 No Slab -on -Grade Garage 462 0.1 None 0 No Registration Number: 214-N0093964A-000000000-0000 Registration Date/Time: 2014-09-1513:46:35 HERS Provider: CA Building Eriergy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:52:07 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-2 A Calculation Date/Time: 20:39, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-2A Run 1.xml CF1R-PRF-NCB-01 Page 9 of 12 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED REQUIRED 4.4 WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Pipe Insulation, All Lines 1 0.0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.575 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 } i`02/ , 'r 4 f v 03/ 04 ,� f-� t fro L+} 05 06 07 Name . Pipe Insulation ' •- .. .f _ L «..' Parallel Piping t�`,,rGf y [ o'+e Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a n/a HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC Split system1 Other Heating and Cooling System Heating Component 1 Yes Cooling Yes Air Distribution HVAC Fan 1 1504 Component 1 System 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 92 AFUE Registration Number: 214-N0093964A-000000000-0000 Registration Date/Time: 2014-09-15 13:46:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:52:07 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-2 A Calculation Description: Title 24 Analysis Calculation Date/Time: 20:39, Tue, May 20, 2014 Input File Name: Codorniz SF-2A Run 1.xml CF1R-PRF-NCB-01 Page 10 of 12 HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 12.5 15 Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Types,,,,'—, Duct Leakage--... R-value-, Location Return Duct Bypass Duct HERS Verification *.Insulation Air Distribution System 1 Verified low leakage�ducts� : in r t i Sealed and tested I ` 8 V Conditioned Zone Conditioned Zone None Air Distribution 1-hers-dist entirely conditioned space / - �' fJ r' \ ta. System HVAC DISTRIBUTION -HERS VERIFICATION y 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required 6.0 Required Not Required Not Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 Registration Number: 214-No093964A-000000000-0000 Registration Date/Time: 2014-09-15.13:46:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:52:07 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-2 A Calculation Description: Title 24 Analysis Calculation Date/Time: 20:39, Tue, May 20, 2014 Input File Name: Codorniz SF-2A Run 1.xml CF1R-PRF-NCB-01 Page 11 of 12 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 45 Exhaust 0 Required COOLING VENTILATION NONE Registration Number: 214-N0093964A-000000000-0000 Registration Date/Time: 2014-09-1513:46:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:52:07 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-2 A Calculation Date/Time: 20:39, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-2A Run 1.xml CF1R-PRF-NCB-01 Page 12 of 12 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: David Bricker Company: Signature Date: RJT Homes 2014-09-15 08:35:12 Address: CEA/HERS Certification Identification (If applicable): PO Box 810 R08-06-207 City/State/Zip: Phone: La Quinta, CA 92253 760-564-6555 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this,Certificate of.Compliiance are consistent -with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications subn itted,to the enforcement agency for approval with`this` building permit application. Responsible Designer Name: i �`c ResponsibleDesigner Signature: @ C��cyer Chad Meyer �"_ 1 ,j Company: Date Signed: RJT Homes 2014-09-15 13:46:35 Address: License: PO Box 810 NA City/State/Zip: Phone: La Quinta, CA 92253 760-564-6555 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-N0093964A-000000000-0000 Registration Date/Time: 2014-09-15 13:46:35 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:52:07 PM I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 15 Form MF-1 R Mandatory Measures Summary 16 HVAC�System Heating and Cooling Loads Summary 19 Room Load Summary 20 Room Heating Peak Loads 21 Room Cooling Peak Loads 23 I EnergyPro 6.1 by EnergySoft Job Number ID: 05082014A User Number: 6168 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Codorniz SF-2 A Building Type 2 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 512212014 Project Address Jefferson Street and Avenue 52 La Quint California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,504 Addition n/a # of Units 1 INSULATION Construction Type Cavity Area (ft) Special Features Status Wall Wood Framed R 15 1,702 Rigid=R-8.0 New Door Opaque Door - no insulation 24 New Demising Wood Framed R 15 325 New Slab Unheated Slab -on -Grade - no insulation 722 Perim = 106' New Roof Wood Framed Attic R 22 826 New Demising Wood Framed w/o Crawl Space R 19 410 New Demising Wood Framed w/o Crawl Space - no insulation 372 New FENESTRATION Total Area: 350 Glazin Percentage: 23.3 Orientation Area(ft2) U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor: 0.35 Exterior Shades Status Front (N) 72.0 0.350 0.32 none none Bug Screen New Right (tM 60.0 0.350 0.32 none none Bug Screen New Front (N) 87.5 0.350 0.32 none none Bug Screen New Left (E) 25.0 0.350 0.32 none none Bug Screen New Rear (S) 20.5 0.350 0.32 none none Bug Screen New Right (IM 3.0 0.510 0.67 none none Bug Screen New Front (N) 24.0 0.340 0.32 none none Bug Screen New Front (N) 40.2 0.320 0.34 none none Bug Screen New Front (N) 18.0 0.340 0.32 5.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 92% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status HVAC Split system Ducted Ducted Conditioned 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.58 All Pipes Ins New EnerqyPro 6.1 by EnerqySoft User Number. 6168 RunCode: 2014-05-22T11:16:42 /D: 05082014A Page 15 of 26 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name Codomiz SF-2 A Date 1512212014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 110.E a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling or equivalent U-factor. 150.0 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 or equivalent U-factor. * 150.0 d : Minimum R-19 insulation in raised wood -frame floor orequivalent U-factor. 150.0 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150.0 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150.0 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2c . §150.00)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150.00)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150.0-B. §150.00)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150.0-13 and Equation 150.0-A. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. 150.0 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150.0 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 05082014A Page 16 of 26 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MFA R Project Name Date Codorniz SF-2 A 5/22/2014 §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tope shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0 m 7: Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150.0 m 10: Flexible ducts cannot have porous inner cores. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 110.4 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §150.0(p): Residential pools stems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150.0(p). Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. 150.0 k 1 C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c). §150.0(k)1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. 150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150.0(k). 150.0 k 2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ftz or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 05082014A Page 17 of 26 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Codomiz SF-2 A 512212014 §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours ' iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 05082014A Page 18 of 26 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY' Project Name Codorniz SF-2 A Date 5/22/2014 System Name HVAC Split system Floor Area 1,504 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,014 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 73,600 21,587 2,102 500 19,706 Total Output (Btuh) 73,600 0 Output (Stuh/s ft) 48•9 0 0 Cooling System 0 0 Output perSystem 46,000 0 0 0 0 Total Output (Btuh) 46,000 2,233 2,102 -2,233 Total Output (Tons) 3•8 0 0 Total Output (Btuh/s ft) 30.6 Total Output (s ft/Ton) 392.3 1 23,820 17,473 Air System CFM perSystem 1.500 HVAC EQUIPMENT SELECTION (cfm) 1,500 Carrier CA16NA048****A Corp.Airflow 32,611 6,544 73,600 Airflow (cfm/s ft) 1.00 Airflow (cfm/Ton) 391.3 Outside Air (%) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 32,611 6,544 73,600 Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions I Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 26 OF 68 OF Outside Air 0 cfm Supply Fan 1,500 cfm 68 OF 69 OF 105 OF Heating Coil LJ 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak) 112/78OF 75/62°F 76/62°F 55/54°F Outside Air -4,- M 0 cfm AL Supply Fan Cooling Coil 1,500 cfm 75 / 62 OF 55 / 54 OF y, ROOM 75 / 62 OF EnergyPro 6.1 by EnergySoft User Number: 6168 RunCode: 2014-05-22T11:16:42 ID: 05082014A Page 19 of 26 ROOM LOAD SUMMARY Project Name Codomiz SF-2 A Date 512212014 System Name HVAC Split system Floor Area 1,504 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible 1st Floor 1st Floor 1 540 11,493 1,009 540 11,493 1,009 299 11,780 2nd Floor 2nd Floor 1 474 10,094 1,093 474 10,094 1,0931 201 7,926 PAGE TOTAL TOTAL* 1,014 21,587 2,102 500 19,706 11,014 21,587 2,102 500 19,706 Total includes ventilation load for zonal systems. EnergyPro 6.1 by EnergySoft User Number: 6168 RunCode: 2014-05-22T11:16:42 ID: 05082014A Page 20 of 26 ROOM HEATING PEAK LOADS Project Name Codorniz SF-2 A Date 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 1st Floor Floor Area 722.0 ftZ Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT'F = = = = = = = c = = = = = = = = = = = = = = = = = = = 42 Btu/hr R-15 Wall w12" EPS 633.5 0.0540 42 1,436 Alpine A272 Horiz Slider 72.0 0.3500 42 1,058 Alpine A571 Single Hung 142.5 0.3500 42 Z095 Wood Door 24.0 1.4500 42 1,462 *R-15 Wall 342.0 0.0950 18 585 Glass Block 3.0 0.6442 42 81 Slab -On -Grade perim = 106.0 0.7300 42 3,250 R-22 Roof Attic 44.0 0.0410 42 76 Items shown with an asterisk (*) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 722 X Area another room 11.00 X 0.299 Height ACH Page Total / 60 ] X AT 10,043 = 1,767 TOTAL HOURLY HEAT LOSS FOR ROOM 11,780 EnergyPro 6.1 by EnergySoft User Number: 6168 RunCode: 2014-05-22T11:16:42 ID: 05082014A Page 21 of 26 ROOM HEATING PEAK LOADS Project Name Codorniz SF-2 A Date 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Floor Area 782.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = c 0 = = = = = = = = = = = = = = = = = = = = 42 Btu/hr R-15 Wall w/2" EPS 1,068.3 0.0540 42 2,422 Alpine A172 Sldg Glass/Patio Door 42.0 0.3400 42 600 Alpine A770 Picture/Fixed 40.2 0.3200 42 540 Alpine A571 Single Hung 50.5 0.3500 42 742 *R-19 Floor No Crawlspace 410.0 0.0490 18 362 *R-0 Floor No Crawlspace 372.0 0.2380 0 0 R-22 Roof Attic 782.0 0.0410 42 1,347 Items shown with an asterisk (*) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 782 X Area another room 8.00 X 0.411 Height ACH Page Total / 60 ] X AT 6,013 = 1,914 TOTAL HOURLY HEAT LOSS FOR ROOM 7,926 EnergyPro 6.1 by EnergySoft User Number: 6168 RunCode: 2014-05-22T11:16:42 ID: 05082014A Page 22 of 26 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codomiz SF-2 A 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 1st Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 722.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Dailv Ranae: 34 OF Opaque Surfaces R-15 Wall w/2" EPS R-15 Wall w/2" EPS Wood Door R-15 Wall w/2" EPS *R-15 Wall R-15 Wall w12" EPS R-22 Roof Attic Orientation (N) (►40 (N) (E) (S) (S M Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = 228.0 0.0540 23.0 240.0 0.0540 33.0 24.0 1.4500 23.0 74.0 0.0540 33.0 342.0 0.0950 25.0 91.5 0.0540 26.0 44.0 0.0410 56.0 Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fenestration Window 9080SLDR 5 Window 2660SH 6 Window 2660SH 7 Window 2660SH 8 Window 260SH 9 Window 2660SH 10 Window 2660SH 11 Window 2640SH 12 Window 2650SH 13 Orientation (N) (N) (N) (N) (N) (E) (E) (S) Shaded Unshaded Btu/hr 132 812 128 101 1 2,6841 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 18.9 72.0 18.9 0.0 18.9 15.0 37.9 0.0 18.9 15.0 18.9 0.0 18.9 15.0 18.9 0.0 18.9 15.0 18.9 0.0 18.9 15.0 18.9 0.0 18.9 15.0 37.9 0.0 18.9 10.0 37.9 0.0 18.9 12.5 18.9 Page Total Btu/hr 1,359 568 283 283 283 283 568 379 237 4, 243 Internal Gain Btu/hr Occupants 2 2 Occupants X 245 Btuh/occ. = 531 Equipment 722 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 1.20 X 31.24 X 37 = 1,478 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,493 Latent Gain Btu/hr Occupants 2 2 Occupants X 155 Btuh/occ. = 336 Infiltration: 4,771 X 1.20 X 31.24 X 0.00376 = q74 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3361 IEnergyPro 6.1 by EnemySoft User Number: 6168 RunCode: 2014-05-22T11:16:42 ID: 05082014A Page 23 of 26 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codorniz SF-2 A 1 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 1si Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 722.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 3) 8"GB 1 (W) 0.0 X 37.2 + 1.5 X 76.2 = 114 Window 3) 8"GB 2 (W) 0.0 X 37.2 + 1.5 X 76.2 = 114 Window 2) 2660 SH 3, 4 (W) 0.0 X 18.9 + 30.0 X 37.9 = 1,136 X + X = X + X - X + X = X + X = X + X = X + X = Page Total 1,365 Internal Gain Btu/hr Occupants 2 2 Occupants X 245 Btuh/occ. = 531 Equipment 722 Floor Area X 0.50 w/sgft = 1,232 Infiltration: 1.064 X 1.20 X 31.24 X 37 = 1,478 Air Sensible CFM ELA 4T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,493 Latent Gain Btu/hr Occupants 2 2 Occupants X 155 Btuh/occ. = 336 Infiltration: 4,771 X 1.20 X 31.24 X 0.00376 = 674 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 336 EnergyPro 6.1 by EnerqySoft User Number: 6168 RunCode: 2014-05-22T11:16:42 ID: 05082014A Page 24 of 26 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codorniz SF-2 A 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 °F Floor Area 782.0 ft2 Outdoor Wet Bulb Temperature 78 °F Indoor Dry Bulb Temperature 75 OF Outdoor Dailv Ranue: 34 °F Opaque Surfaces R-15 Wall w/2" EPS R-15 Wall w/2" EPS R-15 Wall w/2" EPS R-15 Wall w/2" EPS *R-19 Floor No Crawlspace *R-0 Floor No Crawlspace R-22 Roof Attic Orientation (N) (E) (S) (iM I (SIMI Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = c = = = = = = 613.3 0.0540 23.0 158.0 0.0540 33.0 195.0 0.0540 26.0 102.0 0.0540 33.0 410.0 0.0490 25.0 372.0 0.2380 0.0 782.0 0.0410 56.0 Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Door3068FR 18 Window 2620FG 19 Window 2620FG 20 Window 2620FG 21 Door 2868FR 22 Window 2650SH 23 Window 3050SH 24 Window 2040SH 25 Window 3050SH 26 Orientation (N) (N) (N) (N) (N) (N) (N) (S) (iM Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = - 0.0 18.7 24.0 18.7 0.0 19.0 5.0 19.0 0.0 19.0 5.0 19.0 0.0 19.0 5.0 19.0 0.0 18.7 18.0 18.7 0.0 18.9 V.5 18.9 0.0 18.9 15.0 18.9 0.0 18.9 8.0 18.9 0.0 18.9 15.0 37.9 Page Total Btu/hr 761 281 274 182 502 0 1,795 3,796 Btu/hr 448 95 95 95 336 236 283 152 Internal Gain Btu/hr Occupants 2 3 Occupants X 245 Btuh/occ. _ Equipment 782 Floor Area X 0.50 w/sgft = 1. Infiltration: 1.064 X 1.20 X 33.83 X 37 = 1,601 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,0941 Latent Gain Btu/hr Occupants 2 3 Occupants X 155 Btuh/occ. = 364 Infiltration: 4,771 X 1.20 X 33.83 X 0.00376 = 730 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3641 EnergyPro 6.1 by EnergySoff User Number: 6168 Run Code: 2014-05-22T11:16:42 ID: 05082014A Page 25 of 261 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codorniz SF-2 A 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 782.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 2626FG 14 (N) 0.0 X 19.0 + 6.3 X 19.0 = 120 Window 2626FG 15 (N) 0.0 X 19.0 + 6.3 X 19.0 = 120 Window 2626FG 16 (N) 0.0 X 19.0 + 6.3 X 19.0 = 120 Window 2626FG 17 (N) 0.0 X 19.0 + 6.3 X 19.0 = 120 X + X - X + X = X + X = X + X = X + X = Page Total 479 Internal Gain Btu/hr Occupants 2 3 Occupants X 245 Btuh/occ. = 575 Equipment 782 Floor Area X 0.50 w/sgft Infiltration: X 1.20 X 33.83 X FLAQUANTA 1,601 Air Sensible Sensible CFM ELA 4T & SAFETY DEPT. IVA TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM F- M 10,094 vurl STRUCTION Latent Gain Btu/hr Occupants 2 3 Occupants X UATE 5 = 364 Infiltration: 4,771 X 1.20 X 33.83 X 0.00376 = 730 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 364 EnergyPro 6.1 by EnergySoft User Number: 6168 RunCode: 2014-05-22T11:16:42 ID: 05082014A Page 26 of 26 r 4 d OFI::/Oc�, QDlo/% Title 24 Report CEC Approved 2013 Building Energy Efficiency Standards Job Name Codorniz Plan P2X Verbena Avenue 52 and Jefferson Street La Quinta, CA 92253 � i-FY OF LA CCU I NTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE 0A BY Prepared For RJT Homes - Codorniz, LLC Designer Prepared By Dave Bricker Energy Consultant 05082014C AEAPS ENERGY DRIVEN SOLUTIONS INC CAL TITLE 24 REPORTS NCI CERTIFIED AIR BALANCING P. O. Box 6705 LA QUINTA, CA 92248 760-541-9025 FAx 760-775-4723 CHEERS & CALCERTS CERTIFIED HERS RATER DAVEBRICKER@ENERGYDS.NET CABEC CERTIFIED ENERGY ANALYST EDS ENERGY DRIVEN SOLUTIONS INC Note to Plan Checker and Inspector Project Name: Codorniz P2X Job Number: 05082014C Project Designer: RJT Homes - Codorniz, LLC This project EXCEEDS 2013 Title 24 Standards by: • North Facing 3.0% • East Facing 6.9% • South Facing 10.1 % • West Facing 5.7% HERS Measures include: • Verified Building Envelope Air Leakage • Verified HVAC Fan efficacy • Verified HVAC Refrigerant Charge or. Charge Indicator Display • Verified HVAC low leakage ducts entirely in conditioned space • Verified HVAC EER of 12.5 • Verified IAQ Fan BUILDING ENERGY ANALYSIS REPORT PROJECT: Codorniz P2X Jefferson Street and Avenue 52 La Quinta, CA 92253 Project Designer: RJT Homes - Codorniz, LLC 1245 East University Drive Phoenix, AZ 85034 602-257-1656 Report Prepared by: Dave Bricker Energy Driven Solutions Inc P. O. Box 6705 La Quinta, CA 92248 760.541.9025 Job Number: 05082014C Date: 5/22/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 6.1 by Energ Soft User Number.- 6168 ID: 05082014C TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 14 Form MF-1 R Mandatory Measures Summary 15 HVAC System Heating and Cooling Loads Summary 18 Room Load Summary 19 Room Heating Peak Loads 20 Room Cooling Peak Loads 22 EnergyPro 6.1 by EnergySoft Job Number: ID: 05082014C User Number: 6168 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz P2X Calculation Date/Time: 21:08, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz P2X Run 1.xmi CF1R-PRF-NCB-01 Page 1 of 11 GENERAL INFORMATION 01 Project Name Codorniz P2X 02 Calculation Description Title 24 Analysis 03 Project Location Jefferson Street and Avenue 52 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-1e (532) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.1 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 1353 15 Number of Zones 2 16 Slab Area (FT2) 690 17 Number of Stories 2 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 Glazing Percentage (%) 25.9% Detailed help on using the CFAR Certtiftcate"of Compliance �is'available via the, lnternet by either scanning the QR code or browsing t6- http://www.title24energycode.org/t24help/cfl http://www.title24energycode.org/t24help/cfl r.aspx ■ ❑ COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below CITY OF LA QIUINNITA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY Registration Number: 214-N0093962A-000000000-0000 Registration Date/Time: 2014-09-15 13:45:18 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:9:20:42 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz P2X Calculation Description: Title 24 Analysis Calculation Date/Time: 21:08, Tue, May 20, 2014 Input File Name: Codorniz P2X Run 1.xml CF1R-PRF-NCB-01 Page 2 of 11 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) FDesign Design Margin Improvement Space Heating 1.08 0.84 0.24 22.2% Space Cooling 115.53 111.82 3.71 3.2% IAQ Ventilation 0.00 0.00 0.00 NaN Water Heating 17.65 17.51 0.14 0.8% PV Credit ---- 0.00 0.00 ---- North Facing - TOTAL 134.26 130.17 4.09 3.0% Space Heating 1.08 1.28 -0.20 -18.5% Space Cooling 115.53 106.22 9.31 8.1% IAQ Ventilation 0.00 0.00 0.00 NaN Water Heating 17.65 17.51 0.14 0.8% PV Credit ---- 0.00 0.00 ---- East Facing - TOTAL 134.26 125.01 9.25 6.9% Space Heating Space Cooling 1.08+., 0.95 1 r 115.53 102.23� f ' 0.13 13.30 12.0% 11.5% IAQ Ventilation Water Heating, 0.07-�- 0 ' �,17.65 0.00,�, _ „f y _ _`• �7.51�, 0.00 0.14 NaN 0.8% PV Credit ---- 0.00 0.00 ---- South Facing - TOTAL 134.26 120.69 13.57 10.1% Space Heating 1.08 0.64 0.44 40.7% Space Cooling 115.53 108.44 7.09 6.1% IAQ Ventilation 0.00 0.00 0.00 NaN Water Heating 17.65 17.51 0.14 0.8% PV Credit ---- 0.00 0.00 --- West Facing - TOTAL 134.26 126.59 7.67 5.7% Registration Number: 214-No093962A-000000000-0000 Registration Date/Time: 2014-09-15 13:45:18 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:9:20:42 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-NCB-01 Project Name: Codorniz P2X Calculation Date/Time: 21:08, Tue, May 20, 2014 Page 3 of 11 Calculation Description: Title 24 Analysis Input File Name: Codorniz P2X Run 1.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Codorniz P2X 1353 1 3 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ftz) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 1st Floor Conditioned HVAC Split system1 690 10 DHW Sys 1 2nd Floor Conditioned HVAC -Split systeml---,w&63 , 8 DHW Sys 1 Registration Number: 214-N0093962A-000000000-0000 Registration Date/Time: 2014-09-15 13:45:18 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 Report Generated at: 5/20/2014:9:20:42 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz P2X Calculation Date/Time: 21:08, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz P2X Run 1.xml CF1R-PRF-NCB-01 Page 4 of 11 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window Area (ft) Tilt(deg) Exterior Wall front N 8x10 1st Floor R-13 Wall w/1 EPS 0 Front 80 15 90 Exterior Wall right W 4x9 1st Floor R-13 Wall w/1 EPS 270 Right 36 0 90 Exterior Wall front N 6x9 1st Floor R-13 Wall w/1 EPS 0 Front 54 18 90 Exterior Wall left E 4x9 1st Floor R-13 Wall w/1 EPS 90 Left 36 0 90 Exterior Wall front N 4x18 1st Floor R-13 Wall w/1 EPS 0 Front 72 12.5 90 Exterior Wall front N 6x9 2 1st Floor R-13 Wall w/1 EPS 0 Front 54 12.5 90 Exterior Wall rear S 20.3x9 1st Floor R-13 Wall w/1 EPS 180 Back 183 34 90 Exterior Wall right W 13x9 1st Floor R-13 Wall w/1 EPS 270 Right 117 72 90 Exterior Wall rear S 5x10 1st Floor R-13 Wall w/1 EPS 180 Back 50 15 90 Exterior Wall right W 15.5x9 1st Floor R-13 Wall w/1 EPS 270 Right 140 45 90 Roof 1st Floor R-22 Roof Attic 27 Interior Surface 32.5x9 ,.1st Floor»Garagef ^° R-13 Wall-- *»- ,, 293 Exterior Wall front N 10.5x9 Exterior Wall right W 15.2x9 2nd Floor, !.° ' 2nd'Floor/ I ... �', R13 Wali w/1,ERS R-13 Wall w/1 EPS .fl 270 74 Front 1�Right,3 95 137 0 15 90 90 Exterior Wall front N 22x9 ` `2nd Floor - '" - R=13 Wall w/PEPS &-Front 198 21.6 90 Exterior Wall left E 21.2x9 2nd Floor R-13 Wall w/1 EPS 90 Left 189 27.6 90 Exterior Wall rear S 5.5x9 2nd Floor R-13 Wall w/1 EPS 180 Back 50 0 90 Exterior Wall left E 7.3x9 2nd Floor R-13 Wall w/1 EPS 90 Left 66 0 90 Exterior Wall rear S 27x9 2nd Floor R-13 Wall w/1 EPS 180 Back 243 42.6 90 Exterior Wall right W 13.4xg 2nd Floor R-13 Wall w/1 EPS 270 Right 121 20 90 Roof 2 2nd Floor R-22 Roof Attic 663 Exterior Wall front N 13.9x9 Garage Garage Ext Wall 0 Front 125 0 90 Exterior Wall left -7.5x9 Garage Garage Ext Wall 90 Left 68 0 90 Exterior Wall front N 9x9 Garage Garage Ext Wall 0 Front 81 0 90 Exterior Wall left E 21x9 Garage Garage Ext Wall 90 Left 189 0 90 Exterior Wall rear S 21x9 Garage Garage Ext Wall 180 Back 189 0 90 Roof 3 Garage R-0 Roof Attic 525 Registration Number: 214-N0093962A-000000000-0000 Registration Date/Time: 2014-09-1513:45:18 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:9:20:42 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz P2X Calculation Description: Title 24 Analysis Calculation Date/Time: 21:08, Tue, May 20, 2014 Input File Name: Codorniz P2X Run 1.xml CF1 R-PRF-NCB-01 Page 5 of 11 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 4 0.1 0.85 No No low R y / y C Registration Number: 214-N0093962A-000000000-0000 Registration Date/Time: 2014-09-15 13:45:18 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:9:20:42 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz P2X Calculation Date/Time: 21:08, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz P2X Run 1.xml CF1R-PRF-NCB-01 Page 6 of 11 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height (ft) Width(ft ) Multiplie r Area (ft) U- factor SHG C Exterior Shading Window 2660SH 5 Window Exterior Wall front N 8x10 (Front-0) --- -- 1 15.0 0.35 0.32 Window 3060SH 6 Window Exterior Wall front N 6x9 (Front-0) ---- ---- 1 18.0 0.35 0.32 Window 2650SH 7 Window Exterior Wall front N 4x18 (Front-0) ---- ---- 1 12.5 0.35 0.32 Window 2650SH 8 Window Exterior Wall front N 6x9 2 (Front-0) ---- ---- 1 12.5 0.35 0.32 Window 4) 8 GB 9 Window Exterior Wall rear S 20.3x9 (Back-180) ---- -- 1 2.0 0.64 0.66 Window 4) 8 GB 10 Window Exterior Wall rear S 20.3x9 (Back-180) --- 1 2.0 0.64 0.66 Window 2) 2660SH 11 Window Exterior Wall rear S 20.3x9 (Back-180) --- ---- 1 30.0 0.35 0.32 Window 9080SLDR 1 Window Exterior Wall right W 13x9 (Right-270) ---- ---- 1 72.0 0.34 0.32 Window 2660SH 12 Window Exterior Wall rear S 5x10 (Back-180) ---- ---- 1 15.0 0.35 0.32 Window 2660SH 2 Window Exterior Wall right W 15.5x9 (Right-270) ---- ---- 1 15.0 0.35 0.32 Window 2660SH 3 Window Exterior Wall right W 15.5x9 (Right-270) ---- ---- 1 15.0 0.35 0.32 Window 2660SH 4 Window ` ' Exterior Wall right W 15.5x9 (Right-270). 4 _ `' ' ` - - ---- 1 15.0 0.35 0.32 Window 2620FG 15 Window Exterior Wall right`W'152x9 (Right-270) --- _---- -- 1 5.0 0.32 0.34 Window 2620FG 16 Window 4 /f t / °.,#] Exterior Wall'rigKt W 15.2x9 (Right-270 �,� -a- `� � 4 � 1 5.0 0.32 0.34 Window 2620FG 17 Window Exterior Wall right W 15.2x9 (Right-270) --- -- 1 5.0 0.32 0.34 Window 2626FG 18 Window Exterior Wall front N 22x9 (Front-0) ---- ---- 1 6.3 0.32 0.34 Window 2636SH 19 Window Exterior Wall front N 22x9 (Front-0) ---- ---- 1 9.0 0.35 0.32 Window 2626FG 20 Window Exterior Wall front N 22x9 (Front-0) ---- ---- 1 6.3 0.32 0.34 Window 2626FG 21 Window Exterior Wall left E 21.2x9 (Left-90) ---- ---- 1 6.3 0.32 0.34 Window 3050SH 22 Window Exterior Wall left E 21.2x9 (Left-90) --- -- 1 15.0 0.35 0.32 Window 2626FG 23 Window Exterior Wall left E 21.2x9 (Left-90) -- --- 1 6.3 0.32 0.34 Window 2) 3050SH 24,25 Window Exterior Wall rear S 27x9 (Back-180) ---- ---- 1 30.0 0.35 0.32 Window 2626FG 26 Window Exterior Wall rear S 27x9 (Back-180) ---- ---- 1 6.3 0.32 0.34 Window 2626FG 27 Window Exterior Wall rear S 27x9 (Back-180) ---- ---- 1 6.3 0.32 0.34 Door 3068FR 14 Window Exterior Wall right W 13.4x9 (Right-270) ---- ---- 1 20.0 0.34 0.32 Registration Number: 214-N0093962A-000000000-0000 Registration Date/Time: 2014-09-1513:45:18 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:9:20:42 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 132X Calculation Date/Time: 21:08, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz P2X Run 1.xml CF1 R-PRF-NCB-01 Page 7 of 11 DOORS 01 02 03 04 Name Side of Building Area (ft) U-factor Door 3080 Exterior Wall left E 4x9 24.0 1.00 Door 2868 Interior Surface 32.5x9 17.8 1.00 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic floor - Cavity: - no insulation - R-0 Roof Attic Ceilings (below:attic) „,, ,, --„rT 7Woodframed Ceiling ,- -ricer. 2x4 @ 24 in, O.C. ;' Sheathinglnsulation - no sheathing/insul. - Inside Finish: Gypsum Board ' 4j1,j'� Inside Finish: Gypsum Board •i 1 Sheathing/Insulation: - no sheathinghnsul. - r�✓ _ JJJ.. \__ _.. 1 ..1F"L'` t1L� ,• Cavity: R 13 Sheathing/Insulation: - no sheathing/insul. - R-13 Wall w/1 EPS Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 Exterior Finish: R4 Synthetic Stucco Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: R 13 Sheathing/Insulation: - no sheathing/insul. - R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 Other Side Flnish: Gypsum Board Attic Floor: - no attic floor - Cavity: R 22 Sheathinglnsulation - no sheathing/insul. - R-22 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 22 Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: - no insulation - Sheathing/Insulation: - no sheathing/insul. - Garage Ext Wall Exterior Walls Wood Framed Wall . 2x4 @ 16 in. O.C. Exterior Finish: 3 Coat Stucco Registration Number: 214-N0093962A-000000000-0000 Registration Date/Time: 2014-09-1513:45:18 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:9:20:42 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz P2X Calculation Date/Time: 21:08, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz P2X Run 1.xml CF1R-PRF-NCB-01 Page 8 of 11 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Covered Slab 1st Floor 217 24 None 0.8 No Exposed Slab 1st Floor 473 58 None 0.8 No Slab -on -Grade Garage 525 0.1 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED REQUIRED 4.4 WATER HEATING SYSTEMS 01 02 03 04 Name -Distribution Types Number of Heaters Solar Fraction (%) DHW Sys 1 k f' Pipe Insulation, All'Lines ` r t i' 1 0.0% 1 !I I f I - .I l 5 I N WATER HEATERS 01 02 03 04 " 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.575 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a n/a Registration Number: 214-N0093962A-000000000-0000 Registration Date/Time: 2014-09-15 13:45:18 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 Report Generated at: 5/20/2014:9:20:42 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz P2X Calculation Date/Time: 21:08, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz P2X Run 1.xml CF1 R-PRF-NCB-01 Page 9 of 11 HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC Split system1 Other Heating and Cooling System Heating Component 1 Yes Cooling Yes Air Distribution HVAC Fan 1 1353 Component 1 System 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 92 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 Name ,x - � r Sy tem T .. Efficiency '` n,, EER SEER HERS Verification Cooling Component 1 y. SplitA,rC (Split air conditioning system) r 12.5 _ fi , 15 Cooling Component 1-hers-cool A/ _ld .t! ,, I ! ' I, J !i 1/1tIt HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Verified low -leakage ducts Sealed and tested 8 Conditioned Zone Conditioned Zone None Air Distribution entirely in conditioned space System 1-hers-dist Registration Number: 214-N0093962A-000000000-0000 Registration Date/Time: 2014-09-15 13:45:18 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 Report Generated at: 5/20/2014:9:20:42 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz P2X Calculation Date/Time: 21:08, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz P2X Run 1.xml CF1R-PRF-NCB-01 Page 10 of 11 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required 6.0 Required Not Required Not Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 / t ,irr -.% /. 02 A r' L-► 04 05 Name ''' ` " ` IAQ CFM' ' _ "` IAQ Fan Type v t ' IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 44 Exhaust 0 Required COOLING VENTILATION NONE Registration Number: 214-N0093962A-000000000-0000 Registration Date/Time: 2014-09-15 13:45:18 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 Report Generated at: 5/20/2014:9:20:42 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz P2X Calculation Description: Title 24 Analysis Calculation Date/Time: 21:08, Tue, May 20, 2014 Input File Name: Codorniz P2X Run 1.xml CF1 R-PRF-NCB-01 Page 11 of 11 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: 064-iali David Bricker Company: Signature Date: Energy Driven Solutions, Inc. 2014-09-15 08:33:41 Address: CEA/HERS Certification Identification (If applicable): PO Box 6705 R08-06-207 City/State/Zip: Phone: La Quinta, CA 92248 760 541 9025 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this, Certificate of,Compliance.are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted- the enforcement'agency' or approval with ithis" building permit application. Responsible Designer Name: { F ResponsibleDesigner Signature: � r .�'f Chad Chad Meyer \ �el l t� /+ . C/�L yer _,J & ., ., /ail .. Company: Date Signed: RJT Homes 2014-09-15 13:45:18 Address: License: PO Box 810 NA City/State/Zip: Phone: La Quinta, CA 92253 760-564-6555 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-N0093962A-000000000-0000 Registration Date/Time: 2014-09-15 13:45:18 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:9:20:42 PM RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Codorniz P2X Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 512212014 Project Address Jefferson Street and Avenue 52 La QuintJ California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,353 Addition n/ # of Units 1 INSULATION Construction Type Cavity Area (ft) Special Features Status Wall Wood Framed R 13 1,546 Rigid=R-4.0 New Door Opaque Door - no insulation 24 New Demising Wood Framed R 13 275 New Roof Wood Framed Attic R 22 690 New Slab Unheated Slab -on -Grade no insulation 690 Perim = 82' New Demising Wood Framed w/o Crawl Space no insulation 663 New FENESTRATION Total Area: 351FGlaig Percentage: 25•9 Orientation Area(ft2) U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor: 0.35 Exterior Shades Status Front (N) 67.0 0.350 0.32 none none Bug Screen New Rear (S) 4.0 0.510 0.67 none none Bug Screen New Rear (S) 75.0 0.350 0.32 none none Bug Screen New Right (W) 92.0 0.340 0.32 none none Bug Screen New Right (W) 45.0 0.350 0.32 none none Bug Screen New Right (W) 15.0 0.320 0.34 none none Bug Screen New Front (N) 12.6 0.320 0.34 none none Bug Screen New Left (E) 12.6 0.320 0.34 none none Bug Screen New Left (E) 15.0 0.350 0.32 none none Bug Screen New Rear (S) 12.6 0.320 0.34 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 92% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status HVAC Split system Ducted Ducted Conditioned 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.58 All Pipes Ins New EnerqyPro 6.1 by EnergySoft User Number., 6168 RunCode: 2014-05-22T11:03:14 ID: 05082014C Pa a 14 of 25 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name Codomiz P2X Date 512212014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 110.E a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling or equivalent U-factor. 150.0 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 or equivalent U-factor. *§150.0 d : Minimum R-19 insulation in raised wood -frame floor or equivalent U-factor. 150.0 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential -occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150.0 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150.0 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2c . §150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150.00)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150.0-B. §150.00)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150.0-13 and Equation 150.0-A. §150.0Q)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. 150.0 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150.0 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 05082014C Page 15 of 25 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Codomiz P2X 1512212014 §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0 m 7: Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150.0 m 10: Flexible ducts cannot have porous inner cores. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 110.4 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. . §150.0 p : Residential pools stems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150.0(p). Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. 150.0 k 1 C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c). §150.0(k)1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. 150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150.0(k). 150.0 k 2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 05082014C Page 16 of 25 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Codomiz P2X 512212014 §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 05082014C Page 17 of 25 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Codorniz P2X Date 5/22/2014 System Name HVAC Split system Floor Area 1,353 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,032 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 73,600 21,972 1,525 452 17,813 Total Output (Btuh) 73,600 0 Output Btuh/s ft 54.4 0 0 Cooling System o 0 Output per System 46,000 0 0 0 0 Total Output (Btuh) 46,000 2,233 1,525 -2,233 Total Output (Tons) 3•8 0 0 Total Output (Btuh/s ft) 34.0 Total Output (s ft/Ton) 353.0 1 24,206 15,579 Air System CFM per System 1,500 HVAC EQUIPMENT SELECTION (cfm) 1,500 Carrier CA16NA048****A Corp.Airflow 32,814 6,254 73,600 Airflow (cfm/s ft) 1.11 Airflow (cfm/Ton) 391.3 Outside Air (%) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 32,814 6,254 73,600 Outside Air (cfm/5 ft) 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 26 OF 68 OF Outside Air 0 cfm Supply Fan 1,500 cfm 68 OF 69 OF 105 OF Heating Coil 105 OF 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak) 112/78OF 75/62°F Outside Air 0 cfm 75/62°F 76/62°F 55/54°F Supply Fan Cooling Coil 55 / 54 OF 1,500 cfm 47.1 % ROOM 75/62°F EnergyPro 6.1 by EnergySoft User Number: 6168 RunCode: 2014-05-22T11:03:14 ID: 05082014C Page 18 of 25 ROOM LOAD SUMMARY Project Name Date Codomiz P2X 512212014 �HVAC Split system 1, 353 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible 1st Floor 1st Floor 1 575 IZ246 778 575 12,246 778 274 10,778 2ndFloor 2ndFloor 1 457 9,727 747 457 9,727 747 179 7,034 PAGE TOTAL TOTAL * 1,032 21,972 1,525 452 17,813 1,032 21,972 1,5251 452 17,8131 * Total includes ventilation load for zonal systems. EnergyPro 6.1 by EnetpySoft User Number: 6168 RunCode: 2014-05-22T11:03:14 ID: 05082014C Page 19 of 25 ROOM HEATING PEAK LOADS Project Name Codomiz P2X Date 5/2V2014 ROOM INFORMATION DESIGN CONDITIONS Room Name 1st Floor Floor Area 690.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = c = = = = = 0 = = = = = = = = = = = = = = = = = = = = = 42 Btu/hr R-13 Wall w11 " EPS 574.0 0.0724 42 1,746 Alpine A571 Single Hung 148.0 0.3500 42 2,176 Wood Door 24.0 1.4500 42 1,462 'R-13 Wall 293.0 0.1020 18 538 Glass Block 4.0 0.6442 42 108 Alpine A172 Sldg Glass/Patio Door 72.0 0.3400 42 1,028 R-22 Roof Attic 27.0 0.0410 42 46 Slab -On -Grade perim = 82.0 0.7300 42 2,514 Items shown with an asterisk () denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 690 X Area another room 10.00 X 0.232 Height ACH Page Total / 60 J X AT 9,619 = 1,192 TOTAL HOURLY HEAT LOSS FOR ROOM 10,778 EnergyPro 6.1 by EnergySoft User Number. 6168 RunCode: 2014-05-22T11:03:14 ID: 05082014C Page 20 of 25 ROOM HEATING PEAK LOADS Project Name Codorniz P2X Date 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Floor Area 663.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F _ = = = = = = = = = = = = = = = = = = = = = = = — = = = = 42 Btu/hr R-13 Wall w11"EPS 972.2 0.0724 42 2,958 Alpine A770 Picture/Fixed 52.8 0.3200 42 710 Alpine A571 Single Hung 54.0 0.3500 42 794 Alpine A172 Sldg Glass/Patio Door 20.0 0.3400 42 286 R-22 Roof Attic 663.0 0.0410 42 1,142 *R-0 Floor No Crawlspace 663.0 0.2380 0 0 Items shown with an asterisk (*) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 663 X Area another room 8.00 X 0.290 Height ACH Page Total / 60 ] X AT 5,889 0 1,146 TOTAL HOURLY HEAT LOSS FOR ROOM 7,034 EnergyPro 6.1 by EnergySoft User Number: 6168 RunCode: 2014-05-22T11:03:14 ID: 05082014C Page 21 of 25 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codomiz P2X 1 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 1st Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 690.0 ft2 Outdoor Wet Bulb Temperature 78 of Indoor Dry Bulb Temperature 75 OF Outdoor Daily Ranqe: 34 OF Opaque Surfaces R-13 Wall w/1 " EPS R-13 Wall w/1 " EPS R-13 Wall w/1 " EPS Wood Door *R-13 Wall R-13 Wall w/1 " EPS R-22 Roof Attic Orientation Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = 202.0 0.0724 23.0 176.0 0.0724 33.0 12.0 0.0724 33.0 24.0 1.4500 33.0 293.0 0.1020 25.0 184.0 0.0724 26.0 27.0 0.0410 56.0 Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window 2660SH 5 Window 3060SH 6 Window 2650SH 7 Window 2650SH 8 Window 4) 8"GB 9 Window 4) 8"GB 10 Window 2) 2660SH 11 Window 9080SLDR 1 Window 2660SH 12 Orientation (N) (N) (N) (N) (S) (S) (S) (iM (S) Shaded Unshaded Btu/hr 337 421 29 1,148 747 347 1 3,0901 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = - 0.0 18.9 M.0 18.9 0.0 18.9 18.0 18.9 0.0 18.9 12.5 18.9 0.0 18.9 12.5 18.9 0.0 37.2 2.0 37.4 0.0 37.2 2.0 37.4 0.0 18.9 30.0 18.9 0.0 18.7 72.0 37.7 0.0 18.9 15.0 18.9 Page Total Btu/hr 283 340 236 236 75 75 568 2,712 284 4, 809 A Internal Gain Btu/hr Occupants 2•1 Occupants X 245 Btuh/occ. Equipment 690 Floor Area X 0.50 w/sgft = 1, Infiltration: 1.064 X 0.89 X 28.52 X 37 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,246 Latent Gain Btu/hr Occupants 21 Occupants X 155 Btuh/occ. 321 Infiltration: 4,771 X 0.89 X 28.52 X 0.00376 = 457 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3211 I EnergyPro 6.1 by EnergySoft User Number. 6168 RunCode: 2014-05-22T11:03:14 ID: 05082014C Page 22 of 251 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codorniz P2X 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 1st Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 690.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 2660SH 2 (W) 0.0 X 18.9 + 15.0 X 37.9 = 568 Window 2660SH 3 (W) 0.0 X 18.9 + 15.0 X 37.9 = 568 Window 2660SH 4 (lM 0.0 X 18.9 + 15.0 X 37.9 = 568 X + X = X + X = X + X = X + X = X + X = X + X = Page Total 1,704 Internal Gain Btu/hr Occupants _ 2.1 Occupants X 245 Btuh/occ. = 507 Equipment 690 Floor Area X 0.50 w/sgft = 1,177 Infiltration: 1.064 X 0.89 X 28.52 X 37 = 1,002 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,246 Latent Gain Btu/hr Occupants 21 Occupants X 155 Btuh/occ. = 321 Infiltration: 4,771 X 0.89 X 28.52 X 0.00376 = 457 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 321 EnergyPro 6.1 by EnergySoft User Number. 6168 RunCode: 2014-05-22T11:03:14 ID: 05082014C Page 23 of 25 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codomiz P2X 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 663.0 ft2 1 Outdoor Wet Bulb Temperature 78 °F Indoor Dry Bulb Temperature 75 OF Outdoor Dailv Ranae: 34 OF Opaque Surfaces R-13 Wall w/1 " EPS R-13 Wall w/1 " EPS R-13 Wall w/1 " EPS R-13 Wall w/1 " EPS I R-22 Roof Attic -R-0 Floor No Crawlspace Orientation Area X X X X X X X X X U-Factor X X X X X X X X X CLTD� = = = = = = = = = 271.4 0.0724 23.0 223.0 0.0724 33.0 227.4 0.0724 33.0 250.4 0.0724 26.0 663.0 0.0410 56.0 663.0 0.2380 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window 2620FG 15 Window 2620FG 16 Window 2620FG 17 Window 2626FG 18 Window 2636SH 19 Window 2626FG 20 Window 2626FG 21 Window 3050SH 22 Window 2626FG 23 Orientation Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X- GLF = c = = = = = c 0.0 19.0 5.0 39.2 0.0 19.0 5.0 39.2 0.0 19.0 5.0 39.2 0.0 19.0 6.3 19.0 0.0 18.9 9.0 18.9 0.0 19.0 6.3 19.0 0.0 19.0 6.3 39.2 0.0 18.9 15.0 37.9 0.0 19.0 6.3 Page Total Btu/hr 1 Btu/hr 196 196 196 120 170 120 247 568 247 2, 060 Internal Gain Btu/hr Occupants 2.0 Occupants X 245 Btuh/occ. = 487 Equipment 663 Floor Area X 0.50 w/sgft = 1,131 Infiltration: 1.064 X 0.89 X 27.41 X 37 = 963 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 97271 Latent Gain Btu/hr Occupants 20 Occupants X 155 Btuh/occ. = 308 Infiltration: 4,771 X 0.89 X 27.41 X 0.00376 = 439 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3081 EnergyPro 6.1 by EnergySoft User Number: 6168 RunCode: 2014-05-22T11:03:14 ID: 05082014C Page 24 of 25 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codomiz P2X 1 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 663.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 2) 3050SH 24, 25 (S) 0.0 X 18.9 + 30.0 X 18.9 = 568 Window 2626FG 26 (S) 0.0 X 19.0 + 6.3 X 19.1 = 120 Window 2626FG 27 (S) 0.0 X 19.0 + 6.3 X 19.1 = 120 Door 3068FR 14 (W) 0.0 X 18.7 + 20.0 X 37.7 = 753 X + X = X + X = X + X = X + X = X + X = Page Total 1,563 Internal Gain Btu/hr Occupants 2.0 Occupants X j245 j Btuh/occ. = 487 E ui ment 663 Floor Area X 0.50 , M/ q� Z -� O Infiltration: 1.064 X 0.89 X 27.41 X 37 = "D hi > U hi963 Air Sensible CFM ELA AT LL TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM ' od-- 9,727 Latent Gain Q- Btu/hr Occupants _ 2 0 Occupants X 1551�{u ggc 0 = 308 Infiltration: 4,771 X 0.89 X 27.41 X 0.00376 = _� rr ,� v m H °Q 0 439 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 308 EnergyPro 6.1 by EnerqySoft User Number: 6168 RunCode: 2014-05-22T11:03:14 ID: 05082014C Page 25 of 25 Title 24 Report CEC Approved 2013 Building Energy Efficiency Standards Job Name Codorniz Plan SF1 Cassia Avenue 52 and Jefferson Street La Quinta, CA 92253 Prepared For RJT Homes - Codorniz, LLC Designer Prepared By Dave Bricker Energy Consult 05072014A CITY OF LA QUINTA BUILDING & SAFETY D PT. APPROVED FOR CONSTRUCTION DATE I (Z BY, EOsENERGY DRIVEN SOLUTIONS INC CAL TITLE 24 REPORTS NCI CERTIFIED AIR BALANCING P. O. Box 6705 LA QUINTA, CA 92248 760-541-9025 FAx 760-775-4723 CHEERS & CALCERTS CERTIFIED HERS RATER DAVEBRICKER@ENERGYD_S.NET CABEC CERTIFIED ENERGY ANALYST EDSENERGY DRIVEN SOLUTIONS INC Note to Plan Checker and Inspector Project Name: Codorniz SF-1 Job Number: 05072014A Project Designer: RJT Homes - Codorniz, LLC This project EXCEEDS 2013 Title 24 Standards by: • North Facing 15.3% • East Facing 8.8% • South Facing 17.3% • West Facing 7.8% HERS Measures include: • Verified Building Envelope Air Leakage • Verified HVAC Fan efficacy • Verified HVAC Refrigerant Charge or Charge Indicator Display • Verified HVAC low leakage ducts entirely in conditioned space • Verified HVAC EER of 12.5 • Verified IAQ Fan CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY BUILDING ENERGY ANALYSIS REPORT PROJECT: Codorniz SF-1 A Jefferson Street and Avenue 52 La Quinta, CA 92253 Project Designer: RJT Homes - Codorniz, LLC 1245 East University Drive Phoenix, AZ 85034 602-257-1656 Report Prepared by: Dave Bricker Energy Driven Solutions Inc P. O. Box 6705 La Quinta, CA 92248 760.541.9025 Job Number: 05072014A Date: 5/22/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 6.1 by EnergySoft - User Number: 6168 ID: 05072014A TABLE OF CONTENTS Cover Page'. 1 Table of Contents 2 Form CF-I R Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 13 Form MF-1 R Mandatory Measures Summary 14 HVAC System Heating and Cooling Loads Summary 17 Room Load Summary 18 Room Heating. Peak Loads 19 Room Cooling Peak Loads 21 EnergyPro 6.1 by EnergySoft Job Number• ID: 05072014A User Number: 6168 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-1 A Calculation Date/Time: 20:15, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-1A Run 1.xml CFI R-PRF-NCB-01 Page 1 of 10 GENERAL INFORMATION 01 Project Name Codorniz SF-1 A 02 Calculation Description Title 24 Analysis 03 Project Location Jefferson Street and Avenue 52 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-1e (532) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.1 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 1250 15 Number of Zones 2 16 Slab Area (FT2) 647 17 Number of Stories 2 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 Glazing Percentage (%) 24.2% Detailed help on using the CF-1 R Certificate of Compliance WavT7�1'1 9 ailabl,"e via the Internet by either scanning the QR code or browsing to: r' ] f f -sal : ' ! t ., . , . it_ f if (/Lea http://www.title24energycode.org/t24help/cfl r.aspx R1 AA 10 0 � r • 'i ■ ❑ COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY Registration Number: 214-N0093963A-000000000-0000 Registration Date/Time: 2014-09-15 13:46:04 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:26:16 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-1 A Calculation Date/Time: 20:15, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-1A Run 1.xml CF1R-PRF-NCB-01 Page 2of10 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design FSpace Design 7- Margin Improvement Heating 2.11 1.40 0.71 33.6% Space Cooling 130.68 108.18 22.50 17.2% IAQ Ventilation 1.25 1.25 0.00 0.0% Water Heating 18.83 18.69 0.14 0.7% PV Credit -- 0.00 0.00 ---- North Facing - TOTAL 152.87 129.52 23.35 15.3% Space Heating 2.11 1.54 0.57 27.0% Space Cooling 130.68 117.98 12.70 9.7% IAQ Ventilation 1.25 1.25 0.00 0.0% Water Heating 18.83 18.69 0.14 0.7% PV Credit ---- 0.00 0.00 ---- East Facing - TOTAL 152.87 139.46 13.41 8.8% Space Heating Space Cooling 2.11 130.68 / 1/.4177 "', 105.05 y �" 0.70 25.63 33.2% 19.6% IAQ Ventilation Water Heating // 1.25 A ' �18.83 ,4 1.25� , _ ,28.69 �, , 0.00 0.14 0.0% 0.7% PV Credit ---- 0.00 0.00 ---- South Facing -TOTAL 152.87 126.40 26.47 17.3% Space Heating 2.11 1.57 0.54 25.6% Space Cooling 130.68 119.51 11.17 8.5% IAQ Ventilation 1.25 1.25 0.00 0.0% Water Heating 18.83 18.69 0.14 0.7% PV Credit ---- 0.00 0.00 ---- West Facing - TOTAL 152.87 141.02 11.85 7.8% Registration Number: 214-N0093963A-000000000-0000 Registration Date/Time: 2014-09-15 13:46:04 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:26:16 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-NCB-01 Project Name: Codorniz SF-1 A Calculation Date/Time: 20:15, Tue, May 20, 2014 Page 3 of 10 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-1A Run 1.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Codorniz SF-1 A 1250 1 2 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 1st Floor Conditioned HVAC Split system 647 12.1 DHW Sys 1 2nd Floor Conditioned 4 1 .-.HVAC=Split systeml -+ �J,;:-�w603,,?--"J 8 DHW Sys 1 Registration Number: 214-N0093963A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2014-09-1513:46:04 HERS Provider: Report Version - CFiR-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:26:16 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-1 A Calculation Date/Time: 20:15, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-1A Run 1.xmi CF1 R-PRF-NCB-01 Page 4 of 10 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window Area (ft2) Tilt(deg) Exterior Wall front N 7.5x14.5 1st Floor R-13 Wall w/1 EPS 0 Front 109 20 90 Exterior Wall front NW 3x10 1st Floor R-13 Wall w/1 EPS 315 specify - 30 0 90 Exterior Wall front NE 3x10 1st Floor R-13 Wall w/1 EPS 45 specify - 30 0 90 Exterior Wall right W 1st Floor R-13 Wall w/1 EPS 270 Right 4.5 0 90 Exterior Wall front N 8.4x17 1st Floor R-13 Wall w/1 EPS 0 Front 143 55 90 Exterior Wall front N 2.3x8 1st Floor R-13 Wall w/1 EPS 0 Front 18 0 90 Exterior Wall front N 10.3x8 1st Floor R-13 Wall w/1 EPS 0 Front 82 7 90 Exterior Wall left E 18x8 1st Floor R-13 Wall w/1 EPS 90 Left 144 0 90 Exterior Wall rear S 13x14.5 1st Floor R-13 Wall w/1 EPS 180 Back 189 90 90 Exterior Wall right W 16x12.1 1st Floor R-13 Wall w/1 EPS 270 Right 194 40 90 Roof 1st Floor R-22 Roof Attic 44 Interior Surface 29x8 1st Floor»Garage,-R-13,Wall 232 Exterior Wall right W 1.5x9 2nd Floor, f R-13 Wall w/1'dEPS '' 270 Right 14 0 90 Exterior Wall front N 12.7x9 2nd" Floor / R-13 Wall w/1 EPS 0 � , /Front') � 114 30 90 Exterior Wall left E 37.5x9 ` `-`�/2nd Floor R-13 Wall w/VEPS'e L---,90 Pt"4 t=fkSI1'eft 338 20.6 90 Exterior Wall rear S 21x9 2nd Floor R-13 Wall w/1 EPS 180 Back 189 30 90 Exterior Wall right W 10.5x9 2nd Floor R-13 Wall w/1 EPS 270 Right 95 10 90 Roof 2 2nd Floor R-22 Roof Attic 603 Floor over garage 15.8x21 2nd Floor»Garage R-19 Floor No Crawlspace 332 Exterior Wall left 24.25x8 Garage Garage Ext Wall 90 Left 194 0 90 Exterior Wall front 21x8 Garage Garage Ext Wall 180 Back 168 0 90 Exterior Wall right 14.5x8 Garage Garage Ext Wall 270 Right 116 0 90 Roof 3 Garage R-0 Roof Attic 427 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 4 0.1 0.85 No No Registration Number: 214-N0093963A-000000000-0000 Registration Date/Time: 2014-09-15 13:46:04 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:26:16 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-1 A Calculation Date/Time: 20:15, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-1A Run 1.xml CF1R-PRF-NCB-01 Page 5 of 10 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height (ft) Width(ft ) Multiplie r Area (ft) U- factor SHG C Exterior Shading Window 2660SH 5 Window Exterior Wall front N 7.5x14.5 (Front-0) --- -- 1 15.0 0.35 0.32 Window 2620FG 6 Window Exterior Wall front N 7.5x14.5 (Front-0) - 1 5.0 0.32 0.34 Window 2) 9 2660SH 7, Window Exterior Wall front N 8.4x17 (Front-0) --- 1 30.0 0.35 0.32 Window 2) 2620FG 8, 10 Window Exterior Wall front N 8.4x17 (Front-0) ---- ---- 1 10.0 0.32 0.34 Window 2) 2630FG 14,15 Window Exterior Wall front N 8.4x17 (Front-0) ---- ---- 1 15.0 0.32 0.34 Window 2036SH 11 Window Exterior Wall front N 10.3x8 (Front-0) ---- ---- 1 7.0 0.35 0.32 Window 9080 SLDR 12 Window Exterior Wall rear S 13x14.5 (Back-180) ---- ---- 1 72.0 0.35 0.32 Window 9020 FG 13 Window Exterior Wall rear S 13x14.5 (Back-180) ---- ---- 1 18.0 0.32 0.34 Window 2660SH 1 Window '"" f Exterior.Will right W 16z12.1 (Right-270)r � V - --- 1 15.0 0.35 0.32 Window 2620 FG 2 Window Y Exterior Wall right W 16x12.1 (Right-, --- --- 1 5.0 0.32 0.34 Window 2660 SH 3 Window Exterior Wall riight'1N 16z12.1 (Right-270) %T�'.,3 / r.�� --a'"+ 4 1 15.0 0.35 0.32 Window 2620 FG 4 Window " " ` Exterior Wall'right W 16x12.1'(Right-270)`" " ` `` "' --' ` `� t ' `�"� 1 5.0 0.32 0.34 Window 2) 3050SH .16, 17 Window Exterior Wall front N 12.7x9 (Front-0) ---- ---- 1 30.0 0.35 0.32 Window 2040SH 18 Window Exterior Wall left E 37.5x9 (Left-90) ---- ---- 1 8.0 0.35 0.32 Window 2625FG 19 Window Exterior Wall left E 37.5x9 (Left-90) ---- ---- 1 6.3 0.32 0.34 Window 2625FG 20 Window Exterior Wall left E 37.5x9 (Left-90) ---- ---- 1 6.3 0.32 0.34 Window 2) 3050SH 21,22 Window Exterior Wall rear S 21x9 (Back-180) ---- ---- 1 30.0 0.35 0.32 Window 2640SH 23 Window Exterior Wall right W 10.5x9 (Right-270) --- -- 1 10.0 0.35 0.32 DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door 3080 Exterior Wall front NW 3x10 24.0 1.00 Door 2868 Interior Surface 29x8 17.3 1.00 Registration Number: 214-N0093963A-000000000-0000 Registration Date/Time: 2014-09-1513:46:04 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:26:16 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-1 A Calculation Date/Time: 20:15, Tue, May 20, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-1A Run 1.xml CF1 R-PRF-NCB-01 Page 6 of 10 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic floor - Cavity: - no insulation - Sheathinglnsulation - no sheathing/insul. - R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: R 13 Sheathing/Insulation: - no sheathing/insul. - R-13 Wall w/1 EPS Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 Exterior Finish: R4 Synthetic Stucco Inside Finish: Gypsum Board T r' , J-r , Sheathing/Insulation: - no sheathing/insul. - Cavity: R 13 Sheathing/Insulation: - no sheathing/insul. - R-13 Wall Interior Walls Wood Framed Wall: 2x4 @ 16 in. O.C. R 13� •�� Other Side Finish: Gypsum Board Attic Floor: - no attic floor - Cavity: R 22 Sheathinglnsulation - no sheathing/insul. - R-22 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 22 Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: - no insulation - Sheathing/Insulation: - no sheathinghnsul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. Exterior Finish: 3 Coat Stucco SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab -on -Grade exposed 1st Floor 340 47 None 0.8 No Slab -on -Grade covered 1st Floor 307 60 None 0.8 No Slab -on -Grade Garage 427 0.1 None 0 No Registration Number: 214-No093963A-000000000-0000 Registration Date/Time: 2014-09-15 13:46:04 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:26:16 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-1 A Calculation Description: Title 24 Analysis Calculation Date/Time: 20:15, Tue, May 20, 2014 Input File Name: Codorniz SF-1A Run 1.xml CF1 R-PRF-NCB-01 Page 7 of 10 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED REQUIRED 4.4 WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Pipe Insulation, All Lines 1 0.0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.575 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION �� •� -' r �' J� 0102 03 04 .i F t ®05 06 07 Name �L` t T C = '' Pipe Insulation - -1 ' +' - - •� Parallel Piping [ .`..L' (�''if C'�'!o Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a n/a HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC Split system1 Other Heating and Cooling System Heating Component 1 Yes Cooling Yes Air Distribution HVAC Fan 1 125d Component 1 System 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 92 AFUE Registration Number: 214-N0093963A-000000000-0000 Registration Date/Time: 2014-09-1513:46:04 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:26:16 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz SF-1 A Calculation Description: Title 24 Analysis Calculation Date/Time: 20:15, Tue, May 20, 2014 Input File Name: Codorniz SF-1A Run 1.xml CF1R-PRF-NCB-01 Page 8 of 10 HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 12.5 15 Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type. Duct.Leakage, ,Insulation R-value_ Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Verified low leakage ducts . entirely in space' / .' ► • : 1 %:Sealed and tested: 1/ x 8.: ter, . ` k Conditioned Zone Conditioned Zone None Air Distribution 1-hers-dist conditioned i i �' \ (.1System HVAC DISTRIBUTION - HERS VERIFICATION"" :P Lei` v o, 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required 6.0 Required Not Required Not Required HVAC-FAN SYSTEMS 01 02 03 04 Name .Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 Registration Number: 214-N0093963A-000000000-0000 Registration Date/Time: 2014-09-15 13:46:04 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:26:16 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-NCB-01 Project Name: Codorniz SF-1 A Calculation Date/Time: 20:15, Tue, May 20, 2014 Page 9 of 10 Calculation Description: Title 24 Analysis Input File Name: Codorniz SF-1A Run 1.xml IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 35 Exhaust 0 Required COOLING VENTILATION NONE Registration Number: 214-N0093963A-000000000-0000 Registration Date/Time: 2014-09-15 13:46:04 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 Report Generated at: 5/20/2014:8:26:16 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1.R-PRF-NCB-01 Project Name: Codorniz SF-1 A Calculation Description: Title 24 Analysis Calculation Date/Time: 20:15, Tue, May 20, 2014 Input File Name: Codorniz SF-1A Run 1.xml Page 10 of 10 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: David Bricker Company: Signature Date: Energy Driven Solutions, Inc. 2014-09-15 08:34:24 Address: CEA/HERS Certification Identification (If applicable): PO Box 6705 R08-06-207 City/State/Zip: Phone: La Quinta, CA 92248 760 541 9025 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identifiedon this Certificate of.Compliance-are -consistent-with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted*to the enforcement agency for approval with this building permit application. Responsible Designer Name: ` ' �' —1 ResponsibleDesigner Signature: C��cyer Chad Meyer �' �:l _/` •� .......... 1.' _ .�.`., ! �.,. Company: Date Signed: RJT Homes 2014-09-15 13:46:04 Address: License: PO Box 810 NA City/State/Zip: Phone: La Quinta, CA 92253 760-564-6555 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-N0093963A-000000000-0000 Registration Date/Time: 2014-09-15 13:46:04 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/20/2014:8:26:16 PM RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Codorniz SF-1 A Building Type 2 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 512212014 Project Address Jefferson Street and Avenue 52 La QuintJ California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,250 Addition n, # of Units 1 INSULATION Construction Type Cavity Area (ft) Special Features Status Wall Wood Framed R 13 1,361 Rigid=R-4.0 New Wall Wood Framed R 13 6 Rigid=R-4.0 Existing Door Opaque Door - no insulation 24 New Demising Wood Framed R 13 215 New Slab Unheated Slab -on -Grade - no insulation 647 Perim = 107' New Roof Wood Framed Attic R 22 647 New Demising Wood Framed w/o Crawl Space R 19 332 New Demising Wood Framed w/o Crawl Space - no insulation 271 New FENESTRATION I Total Area: 303 Glazing Percentage: 24.2 % Orientation Area(ft2) U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor: 0.34 Exterior Shades Status Front (N) 82.0 0.350 0.32 none none Bug Screen New Front (N) 30.0 0.320 0.34 none none Bug Screen New Rear (S) 72.0 0,350 0.32 none none Bug Screen New Rear (S) 18.0 0.320 0.34 none none Bug Screen New Right (W) 40.0 0.350 0.32 none none Bug Screen New Right (W) 10.0 0.320 0.34 none none Bug Screen . New Left (E) 8.0 0.350 0.32 none none Bug Screen New Left (E) 12.6 0.320 0.34 none none Bug Screen New Rear (S) 30.0 0.350 0.32 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 92% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status HVAC Split system Ducted Ducted Conditioned 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.58 All Pipes Ins New EnerqvPro 6.1 by EnerqySoft User Number: 6168 RunCode: 2014-05-22T11:12:24 ID: 05072014A Page 13 of 23 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name Codomiz SF-1 A Date 1512212014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they.are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building EnvellopW Measures: 110.E a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8 a : Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF-2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF-1 R Form. *§150.0 a : Minimum R-30 (R-19 for Additions/Alterations) insulation in wood -frame ceiling or equivalent U-factor. 150.0 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§150.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 or equivalent U-factor. *§150.0(d): Minimum R-19 insulation in raised wood -frame floor or equivalent U-factor. 150.0 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no qreater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 1 50.0e 1A: Masonry or facto -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning; Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated, appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150.0 h : Heatin and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150.0 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2c . §150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150.00)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150.0-B. §150.00)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150.0-B and Equation 150.0-A. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. 150.0 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150.0 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 05072014A Page 14 of 23 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Codomiz SF-1 A 512212014 §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0 m 7: Exhaust fan systems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150.0 m 10: Flexible ducts cannot have porous inner cores. §150.0(o): All dwelling Units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool orspa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance. heating or a pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-u connections for future solar heating. 110.4 b 2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional. inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150.0(p): Residential pool `systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150.0 p . Residential Lighting Measures: §150.0(k)1 A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. 150.0 k 1 C: The watts a of permanently installed luminaires shall be determined asspecified by §130.0(c). §150.0(k)1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power'per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by-vacancyby-vacancy sensors. 150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150.0(k). 150.0 k 2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150:0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ftz or 100 watts for dwelling units larger than 2,500 ftz may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. EnergyPro 6.1 by EnergySoR User Number. 6168 ID: 05072014A Page 15 of 23 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 WAR Project Name Date Codomiz SF-1 A 512212014 §150.0(k)6: Lighting installed. in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting . installed in rooms or areas oiher.than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached'stora a building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and `ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy,.or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON`and OFF switch that does not override to ON the automatic actions of items ii or. iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight, hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5;,does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential '-building s with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall com . ply with the applicable re uirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. . §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts ofpower-as determined according to 130.0 d . §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor, '. §150.0(k)12B. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable. requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. EnergyPro 6.1 by EnergySoft Use Number..6168 ID: 05072014A Page 16 of 23 HVAC SYSTEM HEATING'AND COOLING LOADS SUMMARY, Project Name Codomiz SF-1 A Date 5/22/2014 System Name HVAC Split system Floor Area 1,250 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 905 Return Vented Lighting . Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 73,600 19,257 1,832 466 18,341 Total Output (Btuh) 73,600 0 Output (Btuh/s ft) 58.9 0 0 Cooling System 0 0 Output per.Systerd, 46,00.0 0 0 0 0 Total Output (Btuh) 46,000 2,233 1 1,832 -2,233 Total Output (Tons) 3.8 0 0 Total Output (Btuh/s ft) 36.8 Total Output (s ft/Ton) 326•1 1 21,491 16,108 Air System CFM per System `, 1,500 HVAC EQUIPMENT SELECTION Airflow cfm 1,500 Carrier Corp. CA16NA048****A 32,706 6,408 73,600 Airflow (cfm/s ft) 1.20 Airflow (cfm/Ton) 3913 Outside Air (%) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 32,706 6,408 73,600 Outside Air (cfrn/s ft) 0.00 Jan 1 AM Note: values above given at ARl conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 26 OF 68 OF ® Outside Air 0 cfm Supply Fan 1,500 cfm 68 OF 69 °F : °.105 OF 1 Heating Coil 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak) 112 / 78 OF 75 / 62 OF 76162 OF 55 / 54 OF - - Outside AirAr -- 0 cfm Supply Fan_ Cooling Coil 55 / 54 OF 1,500cfm, 47.4 % ROOM 75 / 62 OF 75 162 OF EnergyPro 6.1 by EnergySoft User Number. 6168 RunCode: 2014-05-22T11:12:24 ID: 05072014A Page 17 of 23 ROOM LOAD SUMMARY Project Name Codomiz SF-1 A. Date 512212014 System Name HVAC Split system Floor Area 1,250 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible 1st Floor 1st Floor 1 513 10,925 948 513 10,925 948 307 12,106 2nd Floor 2nd Floor 1 391 8,333 884 391 8,333 884 158 6,236 x. .t F 3 t Total includes ventilation load for zonal s sterr EnergyPro 6.1 by EnergySoft User Number: PAGE TOTAL TOTAL is. 6168 RunCode:2014-05-22T11:12: 905 19,257 1,832 466 18,341 905 19,257 1,832 466 18,341 05072014A Page 18 ROOM HEATINGPEAK LOADS Project Name Codorniz SF-1 A Date 512212014 ROOM INFORMATION, DESIGN CONDITIONS Room Name 1 st Floor Floor Area 647.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = = = = = = = = = = _ = = _ = = = = _ = = _ = = _ 42 Btu/hr R-13 Wall w/1 " EPS 707.5 0.0724 42 2,153 Alpine A571 Single Hung 82.0 0.3500 42 1,205 Alpine A770 Picture/Fixed 58.0 0.3200 42 780 Wood Door 24.0 1.4500 42 1,462 *R-13 Wall s 232.0 0.1020 18 426 Alpine A272 Horiz Slider 72.0 0.3500 42 1,058 Slab -On -Grade perim = 107.0 0.7300 42 3,281 R-22 Roof Attic 44.0 0.0410 42 76 4+ } Items shown with an asterisk (*) denote conduction Infiltration:[ 1.00 X ` 1.064 Schedule Air Sensible .Fraction through an interior surface X 647 X Area another room 12.10 X 0.291 Height ACH Page Total / 60 ] X AT 10,440 = 1,698 TOTAL HOURLY HEAT LOSS FOR ROOM 12,106 EnergyPro 6.1 by EnergySoft User Number: 6168 RunCode: 2014-05-22T11:12:24 ID: 05072014A Page 19 of 23 ROOM HEATING PEAK LOADS Project Name Codorniz SF-1 A , 75/22/201-4 ROOM INFORMATION. DESIGN CONDITIONS Room Name j " 2nd Floor Floor Area 603.0 ft2 Indoor Dry Bulb Temperature. 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT'F = = = = = = _ = _ _ _ 42 Btu/hr R-13 Wall w/1"EPS 659.4 0.0724 42 2,006 Alpine A571 Single Hung. 78.0 0.3500 42 1,147 Alpine A770 Picture/Fixed 12.6 0.3200 42 169 *R-19 Floor No Crawlspace 332.0 0.0490 18 293 *R-0 Floor No Crawlspace 271.0 0.2380 0 0 R-22 Roof Attic 603.0 0.0410 42 1,038 'r #' s* s= i, r ! t' 4 Items shown with an asterisk (*) denote ''.conduction Infiltration:[ 1.00 X 1 Schedule Air Sensible Fraction through an interior surface X 603 X Area another room 8.00 X 0.440 Height ACH Page Total / 60 J X AT 4,653 = 1,582 064 TOTAL HOURLY HEAT LOSS FOR ROOM 6,236 EnergyPro 6.1 by EnergySoft User Number: 6168 RunCode: 2014-05-22T11:12:24 ID: 05072014A Page 20 of 23 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codorniz SF-1 A 5/22/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name 1st Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 647.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation R-13 Wall w11 " EPS R-13 Wall w/1 " EPS Wood Door R-13 Wall w/1 " EPS R-13 Wall w/1 " EPS R-13 Wall w/1 " EPS *R-13 Wall R-13 Wall w/1 " EPS R-22 Roof Attic (N) (NM (NM (NE) W (E) (S) (SM Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = 270.0 0.0724 23.0 6.0 0.0724 30.2 24.0 1.4500 30.2 30.0 0.0724 29.0 158.5 0.0724 33.0 144.0 0.0724 33.0 232.0 0.1020 25.0 99.0 0.0724 26.0 44.0 0.0410 56.0 Page Total L Items shown with an asterisk (*)-denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD). Shaded Unshaded Fenestration Orientation Area GLF Area GLF Window 2660SH 5 Window 2620FG 6 Window 2) 2660SH 7, 9 Window 2) 2620FG 8, 10 Window 2) 2630FG 14, 15 Window 2036SH 11 Window 9080 SLDR 12 Window 9020 FG 13 Window 2660SH 1 0.0 X X X X X X X X X 18.9 + + + + + + + + + 15.0 X X X X X X X X X 18.9 = = = = = = = = 0.0 19.0 5.0 19.0 0.0 18.9 30.0 18.9 0.0 19.0 10.0 19.0 0.0 19.0 15.0 19.0 0.0 18.9 7.0 18.9 0.0 18.9 72.0 18.9 0.0 19.0 18.0 19.1 0.0 18.9 15.0 Btu/hr 13 1,052 63 379 344 592 186 101 3,180 Btu/hr 283 95 566 190 285 132 1,364 344 Page Total 3,828 Internal Gain Btu/hr Occupants 19 Occupants X 245 Btuh/occ. = 476 Equipment 647 Floor Area X 0.50 w/Sgft = 1,104 Infiltration: 1.064 X 1.20 X 30.01 X 37 = 1,421 Air Sensible CFM r ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,925 Latent Gain Btu/hr Occupants 1 9 Occupants X 155 Btuh/occ. = 301 Infiltration: 4,77t X 1.20 X 30.01 X 0.00376 = 647 Air Sensible CFM . ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 301 EnergyPro 6.1 by EnerqySoft User Number: 6168 RunCode: 2014-05-22T11:12:24 ID: 05072014A Page 21 of 23 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codorniz SF-1 A 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 1st Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 647.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X _ X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) s Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 2620 FG 2 (W) 0.0 X 19.0 + 5.0 X 39.2 = 196 Window 2660 SH 3 (W), 0.0 X 18.9 + 15.0 X 37.9 = 568 Window 2620 FG 4 (W) 0.0 X 19.0 + 5.0 X 39.2 = 196 X + lx = X + X = X + X = X + X = X + X = X + X = Page Total 960 Internal Gain Btu/hr Occupants 19 Occupants X 245 Btuh/occ. = 476 Equipment 647 Floor Area X 0.50 w/sgft = 1,104 Infiltration: 1.064 X 1.20 X 30.01 X 37 = 1,421 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,925 Latent Gain Btu/hr Occu ants 1 9 Occupants X �— 155 Btuh/occ. = 301 Infiltration: 4;771 X, 1.20 X 30.01 X 0.00376 = 647 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 301 Ener.gyPro 6.1 by EnerqySoft _ User Number: 6168 RunCode: 2014-05-22T11:12:24 ID: 05072014A Page 22 of 23 RESIDENTIAL ROOM' COOLING LOAD SUMMARY Project Name Date Codomiz SF-1 A 512212014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 °F Floor Area 603.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature - 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-13 Wall w/1 " EPS (W) 99.0 X 0.0724 X 33.0 = 237 R-13 Wall w/1"EPS (N) 84.0 X 0,0724 X 23.0 = 140 R-13 Wall w/1 " EPS (E) 317.4 X 0.0724 X 33.0 = 759 R-13 Wall w/1 " EPS (S) 159.0 X 0.0724 X 26.0 = 299 *R-19 Floor No Crawlspace 332.0 X 0.0490 X 25.0 = 407 *R-0 Floor No Crawlspace 271.0 X 0.2380 X 0.0 = 0 R-22 Roof Attic (SIM 603.0 X 0.0410 X 56.0 = 1,384 X X = X X = Page Total 3,226 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 2) 3050SH 16, 17 (N) 0.0 X 18.9 + 30.0 X 18.9 = 566 Window 2040SH 18 (E) : 0.0 X 18.9 + 8.0 X 37.9 = 303 Window 2625FG 19 (E) 0.0 X 19.0 + 6.3 X 39.2 = 247 Window 2625FG 20 (E) 0.0 X 19.0 + 6.3 X 39.2 = 247 Window 2) 3050SH 21, 22 (S) 0.0 X 18.9 + 30.0 X 18.9 = 568 Window 2640SH 23 (W) . 0.0 X 18.9 + 10.0 X 37.9 = 379 X + X - X + X X + X = Page Total 2,310 Internal Gain Btu/hr Occupants 1.8 Occupants X 245 Btuh/occ. = 443 Equipment 603 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 1.20 .X 27.97 X 37 = 1,324 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM �.,Y �- , ,�,. 8,333 IA MINIMA Latent Gain BUILDING & SAFETY DEPT. Btu/hr Occupants 1.8 Occupants X 1 .5 tuh/o���� = 280 Infiltration: 4, 771 X 1.20 X 27.97 X 0.0037 FOR = CONSTRUCTION 603 Air Sensible CFM ELA AW DATE 8Y TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 280 EnerqvPro 6.1 by Ener Soft User Number: 6168 RunCode: 2014-05-22T11:12:24 ID: 05072014A Page 23 of 23 Title 24 Report CEC Approved 2013 Building Energy Efficiency Standards Job Name Codorniz Plan 4-2 (Right Half) Avenue 52 and Jefferson Street La Quinta, CA 92253 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE I2 BY Prepared For RJT Homes - Codorniz, LLC Designer Prepared By Dave Bricker Energy Consultant 05212014A LEDSENERGY DRIVEN SOLUTIONS INC CAL TITLE 24 REPORTS NCI CERTIFIED AIR BALANCING P.O. Box 6705 LA QUINTA, CA 92248 760-541-9025 FAx 760-775-4723 CHEERS & CALCERTS CERTIFIED HERS RATER DAVEBRI_CKER@ENERG_Y_DS.NET CABEC CERTIFIED ENERGY ANALYST EDSENERGY DRIVEN SOLUTIONS INC Note to Plan Checker and Inspector Project Name: Codorniz 4-2 (Right Half) Job Number: 05212014A Project Designer: RJT Homes - Codorniz, LLC This project EXCEEDS 2013 Title 24 Standards by: • North Facing 6.9% • East Facing 3.5% • South Facing 12.0% • West Facing 1.4% HERS Measures include: • Verified < 12' of ducts in unconditioned space • Verified HVAC Fan efficacy • Verified HVAC Refrigerant Charge or Charge Indicator Display • Verified HVAC duct testing • Verified HVAC low leakage air handler • Verified HVAC 12 EER and 14 SEER • Verified IAQ Fan BUILDING ENERGY ANALYSIS REPORT PROJECT: Codorniz Plan 4-2 (Right Half) 2013 Standards Avenue 52 and Jefferson Street La Quinta, CA 92253 Project Designer: RJT Homes - Codorniz, LLC 1245 East University Drive Phoenix, AZ 85034 602-257-1656 Report Prepared by: Dave Bricker Energy Driven Solutions Inc P. O. Box 6705 La Quinta, CA 92248 760.541.9025 Job Number: 05212014A Date: 5/23/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro6.1 by EnergySoft User Number. 6168 ID: 05212014A I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 13 Form MF-1 R Mandatory Measures Summary 14 HVAC System Heating and Cooling Loads Summary 17 Room Load Summary 18 Room Heating Peak Loads 19 Room Cooling Peak Loads 21 EnergyPro 6.1 by EnergySoft Job Number: ID: 05212014A User Number 6168 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 4-2 (Right Half) 2013 Standards Calculation Date/Time: 13:36, Fri, May 23, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz 4-2 Run 4 (2013 Standards).xml CF1R-PRF-NCB-01 Page 1 of 10 GENERAL INFORMATION 01 Project Name Codorniz 4-2 (Right Half) 2013 Standards 02 Calculation Description Title 24 Analysis 03 Project Location Avenue 52 and Jefferson Street 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-1 a (532) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.1 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 1655 15 Number of Zones 2 16 Slab Area (FT2) 778 17 Number of Stories 2 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 Glazing Percentage (%) 19.1% �' a Detailed help on using the CFAR Certtificate of Compliance is available via the Internet by either scanning the QR code or,browsng to: http://www.title24energycode.org/t24help/cfl r.aspx ■ ❑ COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ►� i 7 FN.A ',3U DING & SAFETY DEP T - APPRO E FOR CONSTRUCTION DATE _BY Registration Number: 214-N0093961A-000000000-0000 Registration Date/Time: 2014-09-15 13:44:20 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 CaICERTS inc. Report Generated at: 5/23/2014:1:46:38 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 4-2 (Right Half) 2013 Standards Calculation Date/Time: 13:36, Fri, May 23, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz 4-2 Run 4 (2013 Standards).xml CF1R-PRF-NCB-01 Page 2 of 10 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) FDesign Design Margin Improvement Space Heating 2.13 1.56 0.57 26.8% Space Cooling 113.78 108.19 5.59 4.9% IAQ Ventilation 1.26 1.26 0.00 0.0% Water Heating 15.10 12.16 2.94 19.5% PV Credit --- 0.00 0.00 ---- North Facing - TOTAL 132.27 123.17 9.10 6.9% Space Heating 2.13 1.87 0.26 12.2% Space Cooling 113.78 112.34 1.44 1.3% IAQ Ventilation 1.26 1.26 0.00 0.0% Water Heating 15.10 12.16 2.94 19.5% PV Credit ---- 0.00 0.00 ---- East Facing - TOTAL 132.27 127.63 4.64 3.5% Space Heating Space Cooling y 213 �.. ' 113.78 �-- 1:34 41 7/ 101.64 0.79 12.14 37.1 % 10.7% F �.1� IAQ Ventilation 1.26 ' �1.26 0.00 0.0% Water Heating 15.10' •- ) 12.16 �- ,; jjy.L , 2.94 19.5% PV Credit ---- 0.00 0.00 ---- South Facing - TOTAL 132.27 116.40 15.87 12.0% Space Heating 2.13 1.43 0.70 32.9% Space Cooling 113.78 115.53 -1.75 -1.5% IAQ Ventilation 1.26 1.26 0.00 0.0% Water Heating 15.10 12.16 2.94 19.5% PV Credit ---- 0.00 0.00 ---- West Facing - TOTAL 132.27 130.38 1.89 1.4% Registration Number: 214-N0093961A-000000000-0000 Registration Date/Time: 2014-09-15 13:44:2o HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/23/2014:1:46:38 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-NCB-01 Project Name: Codorniz 4-2 (Right Half) 2013 Standards Calculation Date/Time: 13:36, Fri, May 23, 2014 Page 3 of 10 Calculation Description: Title 24 Analysis Input File Name: Codorniz 4-2 Run 4 (2013 Standards).xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. Ducts with high level of insulation BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Number of Dwelling Number of Ventilation Number of Water Project Name Conditioned Floor Area (sft) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems Codorniz 4-2 (Right Half) 2013 Standards 1655 1 3 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ftz) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Ground Floor Conditioned HVAC1 _ 778 ,u 9.1 DHW Sys 1 Second Floor �C;6d' itiori6d HVAC1, 877' 8 DHW Sys 1 Registration Number: 214-N0093961A-000000000-0000 Registration Date/Time: 2014-09-15 13:44:20 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 Report Generated at: 5/23/2014:1:46:38 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 4-2 (Right Half) 2013 Standards Calculation Date/Time: 13:36, Fri, May 23, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz 4-2 Run 4 (2013 Standards).xml CFI R-PRF-NCB-01 Page 4 of 10 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window Area (ft2) Tilt(deg) Wall front N 7.3x10 Ground Floor R-15 Wall w/1 EPS 90 Left 73 0 90 Exterior Wall left E 5.1x10 Ground Floor R-15 Wall w/1 EPS 90 Left 51 10 90 Exterior Wall front N 13.75x10 Ground Floor R-15 Wall w/1 EPS 0 Front 138 0 90 Exterior Wall N 11.6x10 Ground Floor R-15 Wall w/1 EPS 0 Front 116 0 90 Exterior Wall front N 15.6x10 Ground Floor R-15 Wall w/1 EPS 0 Front 156 44 90 Exterior Wall right W 16x10 Ground Floor R-15 Wall w/1 EPS 270 Right 160 44 90 Exterior Wall rear S 5x10 Ground Floor R-15 Wall w/1 EPS 180 Back 50 16.5 90 Exterior Wall right W 13x10 Ground Floor R-15 Wall w/1 EPS 270 Right 130 60 90 Exterior Wall rear S 20.9x10 Ground Floor R-15 Wall w/1 EPS 180 Back 209 42.5 90 Interior Surface 25.8x9 Ground Floor»Garage R-15 Wall (W.15.2x4.16) 232 Exterior Wall front N 7.3x8 Second Floor R-15 Wall w/1 EPS 0 Front 58 0 90 Exterior Wall left E 5.1x8 ,.; Second Floor,., � +.—R-15, Wall w/11EP'S /90� Left 41 10 90 Exterior Wall front N 18.4x8 Second.F,loor/, R-15 Wall w/1,EPS 0 Front 147 18 90 Exterior Wall right W 3.6x8 (< Second Flooi R-15 Wall w/1 EPS 270, 'Rights 30 0 90 Exterior Wall front N 5x8 * `'`Second Floor R-15 Wall w/1,EPS'f -• .w.0, � �� -Front 40 0 90 Exterior Wall right W 12.25x8 Second Floor R-15 Wall w/1 EPS 270 Right 98 5.6 90 Exterior Wall front N 12x8 Second Floor R-15 Wall w/1 EPS 0 Front 96 5.6 90 Exterior Wall right W 13.25x8 Second Floor R-15 Wall w/1 EPS 0 Front 106 24 90 Exterior Wall rear S 37.75x8 Second Floor R-15 Wall w/1 EPS 180 Back 302 24 90 Exterior Wall left E 8.8x8 Second Floor R-15 Wall w/1 EPS 90 Left 70 0 90 Exterior Wall rear S 5.25x8 Second Floor R-15 Wall w/1 EPS 180 Back 42 12 90 Roof Second Floor R-22 Roof Attic 877 Floor over Garage Second Floor»Garage R-19 Floor No Crawlspace 435 Exterior Wall front N 7.3x9 Garage Garage Ext Wall 0 Front 66 0 90 Exterior Wall left E 23.8x9 Garage Garage Ext Wall 90 Left 214 0 90 Exterior Wall rear S 20.5x9 Garage Garage Ext Wall 180 Back 185 0 90 Roof 2 Garage R-0 Roof Attic 50 Registration Number: 214-No093961A-000000000-0000 Registration Date/Time: 2014-09-15 13:44:20 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/23/2014:1:46:38 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 4-2 (Right Half) 2013 Standards Calculation Date/Time: 13:36, Fri, May 23, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz 4-2 Run 4 (2013 Standards).xml CF1R-PRF-NCB-01 Page 5 of 10 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 2.99194 0.1 0.85 No No WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height (ft) Width(ft ) Multiplie r Area (ft2) U- factor SHG C Exterior Shading Window 2050 Window Exterior Wall left E 5.1x10 (Left-90) ---- --- 1 10.0 0.32 0.34 Window 8056 Window Exterior Wall front N 15.6x10 (Front-0) ---- -- 1 44.0 0.35 0.32 Window 8056 2 Window Exterior Wall right W 16x10 (Right-270) ---- ---- 1 44.0 0.35 0.32 Window 3056 Window Exterior Wall rear S 5x10 (Back-180) ---- --- 1 16.5 0.35 0.32 Window 9067 Window Exterior Wall right W 13x10 (Right-270) ---- --- 1 60.0 0.34 0.32 Window 5056 Window Exterior Wall rear S 20.9x10 (Back-180) ---- ---- 1 27.5 0.35 0.32 Window 3446 Window 205OF Window r Window R Exterior;Wall iear.S 20.9x10,(Back-180) j' �"� 'Exterior Wall left E 5:1x8 (l eft-96) ' ��- --- --- --- 1 1 15.0 10.0 0.35 0.32 0.32 0.34 Window 4640 Window / Exterior Wall front N 18:4x8 Front-0 / 0 ` r ` 1 18.0 0.35 0.32 Window 1316x3 Window Exterior Wall right W 12.25x8 (Right-270) j-- - - ' 1 5.6 0.32 0.34 Window 1316x3 2 Window Exterior Wall front N 12x8 (Front-0) ---- ---- 1 5.6 0.32 0.34 Door 308OFR Window Exterior Wall right W 13.25x8 (Front-0) ---- ---- 1 24.0 0.34 0.32 Window 1316x3 3 Window Exterior Wall rear S 37.75x8 (Back-180) ---- ---- 1 5.6 0.32 0.34 Window 2440 Window Exterior Wall rear S 37.75x8 (Back-180) ---- ---- 1 9.2 0.35 0.32 Window 2440 2 Window Exterior Wall rear S 37.75x8 (Back-180) ---- --- 1 9.2 0.35 0.32 Window 3040 Window Exterior Wall rear S 5.25x8 (Back-180) ---- ---- 1 12.0 0.35 0.32 DOORS 01 02 03 04 Name Side of Building Area (ft) U-factor Door 3080 Exterior Wall N 11.6x10 24.0 0.50 Door 2868 Interior Surface 25.8x9 18.7 0.50 Registration Number: 214-No093961A-000000000-0000 Registration Date/Time: 2014-09-15 13:44:2o HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/23/2014:1:46:38 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 4-2 (Right Half) 2013 Standards Calculation Date/Time: 13:36, Fri, May 23, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz 4-2 Run 4 (2013 Standards).xml CF1R-PRF-NCB-01 Page 6 of 10 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic floor - Cavity: - no insulation - Sheathinglnsulation - no sheathinglinsul. - R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: R 15 Sheathing/Insulation: - no sheathing/insul. - R-15 Wall w/1 EPS Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 Exterior Finish: R4 Synthetic Stucco Inside Finish: Gypsum Board r' 1 Sheathing/Insulation: - no sheathing/insul. - Cavity: R 15 R-15 Wall /Sheathing/Insulation: 7x4 - no sheathing/insul. - (W.15.2x4.16) Interior WallWood Framed Wall 6 in. O.C. R 151 Other Side Flnish: Gypsum Board Attic Floor: - no attic floor - Cavity: R 22 Sheathinglnsulation - no sheathing/insul. - R-22 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 22 Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: - no insulation - Sheathing/Insulation: - no sheathing/insul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. Exterior Finish: 3 Coat Stucco SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (W) Perimeter (ft) Edge Insul. R-valuel£ Depth Carpeted Fraction Heated Slab -on -Grade covered Ground Floor 427 49 None 0.8 No Slab -on -Grade exposed Ground Floor 351 82 None 0.8 No Garage Slab -on -Grade Garage 470 28 None 0 No Registration Number: 214-N0093961A-000000000-0000 Registration Date/Time: 2014-09-15 13:44:2o HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/23/2014:1:46:38 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-NCB-01 Project Name: Codorniz 4-2 (Right Half) 2013 Standards Calculation Description: Title 24 Analysis Calculation Date/Time: 13:36, Fri, May 23, 2014 Input File Name: Codorniz 4-2 Run 4 (2013 Standards).xml Page 7 of 10 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED NOT REQUIRED --- WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Standard 1 0.0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 48 0.66 67000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 1 01 i �02�% 03/ 04 �-, , r 05 06 07 f 'C '' - - •!-` ./�`y (*G' C �LyG Recirculation with Recirculation with Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Manual Control Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a n/a HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HNAC1 Other Heating and Cooling System Heating Component 1 Yes Cooling Yes Air Distribution HVAC Fan 1 1655 Component 1 System 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 94 AFUE Registration Number: 214-N0093961A-000000000-0000 Registration Date/Time: 2014-09-1513:44:2o HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/23/2014:1:46:38 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 4-2 (Right Half) 2013 Standards Calculation Description: Title 24 Analysis Calculation Date/Time: 13:36, Fri, May 23, 2014 Input File Name: Codorniz 4-2 Run 4 (2013 Standards).xml CF1 R-PRF-NCB-01 Page 8 of 10 HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 12 14 Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type . sir . Duct Leakage - _ ,. -. _Insulation Rwalue Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located within the conditioned `space (except:<"12 ` �� • / (Specified Lower °Leakage Target ' .8 Conditioned Zone Conditioned Zone None Air Distribution System 1-hers-dist ,lineal ft) �� ; t jjj , A . , �. r. . HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required 6.0 Required Not Required Not Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 Registration Number: 214-No093961A-000000000-0000 Registration Date/Time: 2014-09-15 13:44:2o HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/23/2014:1:46:38 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-NCB-01 Project Name: Codorniz 4-2 (Right Half) 2013 Standards Calculation Date/Time: 13:36, Fri, May 23, 2014 Page 9 of 10 Calculation Description: Title 24 Analysis Input File Name: Codorniz 4-2 Run 4 (2013 Standards).xml IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 47 Exhaust 0 Required COOLING VENTILATION NONE C" rr r Registration Number: 214-No093961A-000000000-0000 Registration Date/Time: 2014-09-15 13:44:2o HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 Report Generated at: 5/23/2014:1:46:38 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 4-2 (Right Half) 2013 Standards Calculation Date/Time: 13:36, Fri, May 23, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz 4-2 Run 4 (2013 Standards).xml CF1 R-PRF-NCB-01 Page 10 of 10 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: David Bricker Company: Signature Date: Energy Driven Solutions, Inc. 2014-09-15 08:16:23 Address: CEA/HERS Certification Identification (If applicable): PO Box 6705 R08-06-207 City/State/Zip: Phone: La Quinta, CA 92248 760 541 9025 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this; Certificate of.Compliance are,consistentwith the information provided on other applicable compliance documents, worksheets, calculations, plans and 'specifications submitted,to the enforcement agency for approval with this building permit application. Responsible Designer Name: f f ,' 'j ResponsibleDesigner Signature: h.d Chad Meyer L� .. 1 �' � -� - ,f - . . C cX a e er ,.J �'�1 l . � '/.� I...� Company: Date Signed: RJT Homes 2014-09-15 13:44:20 Address: License: PO Box 810 NA City/State/Zip: Phone: La Quinta, CA 92253 760-564-6555 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-N0093961A-000000000-0000 Registration Date/Time: 2014-09-15 13:44:20 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/23/2014:1:46:38 PM RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Codorniz Plan 4-2 (Right Half) 2013 Stand Building Type [0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/23/2014 Project Address Avenue 52 and Jefferson Street La QuintJ California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,655 Addition n/a # of Units 1 INSULATION Construction Type Cavity Area ftz Special Features Status Wall Wood Framed R 15 1,773 Rigid=R-4.0 New Door Opaque Door no insulation 24 New Slab Unheated Slab -on -Grade - no insulation 778 Perim = 131' New Demising Wood Framed R 15 213 New Roof Wood Framed Attic R 22 877 New Demising Wood Framed w/o Crawl Space R 19 435 New Demising Wood Framed w/o Crawl Space - no insulation 442 New FENESTRATION Total Area: 316 Glazing Percentage: 19•1 % Orientation Area(ft2) U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor: 0.34 Exterior Shades Status Left (E) 20.0 0.320 0.34 none none Bug Screen New Front (N) 62.0 0.350 0.32 none none Bug Screen New Right (IM 44.0 0.350 0.32 none none Bug Screen New Rear (S) 59.0 0.350 0.32 none none Bug Screen New . Right (W) 60.0 0.340 0.32 none none Bug Screen New Right (lM 5.6 0.320 0.34 none none Bug Screen New Front (N) 5.6 0.320 0.34 none none Bug Screen New Front (N) 24.0 0.340 0.32 none none Bug Screen New Rear (S) 5.6 0.320 0.34 none none Bug Screen New Rear (S) 30.4 0.350 0.32 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 94% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status HVAC Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Gas 48 0.66. Standard New EnerqyPro 6.1 by EnerqySoft User Number: 6168 RunCode: 2014-05-23T14:20:46 ID: 05212014A Pa e 13 of 22 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 WAR Project Name Codorniz Plan 4-2 (Right Half) 2013 Standards Date 512312014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 110.E a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar He Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling orequivalent U-factor. 150.0 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§150.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 or equivalent U-factor. *§150.0 d : Minimum R-19 insulation in raised wood -frame floor or equivalent U-factor. 150.0 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 a lA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150.0 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150.0 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2c . §150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150.00)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150.0-B. §150.00)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150.0-B and Equation 150.0-A. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. 150.0 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150.0 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 05212014A Page 14 of 22 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MFA R Project Name Date Codorniz Plan 4-2 (Right Halo 2013 Standards 1512312014 §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0 m 7: Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150.0 m 10: Flexible ducts cannot have porous inner cores. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 110.4 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only during off-peak electric demand periods. 150.0 p : Residential pools stems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150.0(p). Residential Lighting Measures: §150.0(k)1 A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. 150.0 k 1 C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c). §150.0(k)1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per Iuminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. 150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150.0(k). 150.0 k 2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy Iuminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 05212014A Page 15 of 22 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 WAR Project Name Date Codorniz Plan 4-2 (Right Half) 2013 Standards 512312014 §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:. i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6., and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 05212014A Page 16 of 22 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Codorniz Plan 4-2 (Right Half) 2013 Standards Date 5/23/2014 System Name HVAC Floor Area 1,655 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,017 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per S stem 80,000 21,368 1,804 489 19,172 Total Output (Btuh) 80,000 0 Output (Btuh/s ft) 48.3 404 302 Cooling System 0 0 Output per System 46,000 0 0 0 0 Total Output (Btuh) 46,000 2,233 1,804 -2,233 Total Output (Tons) 3•8 404 302 Total Output (Btuh/s ft) 27.8 Total Output s ft/Ton) 431.7 1 24,409 17,541 Air System CFM per System 1,500 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,500 Carrier Corp. CA16NA048****A 32,975 6,179 80,000 Airflow (cfm/s ft) 0.91 Airflow (cfm/Ton) 391.3 Outside Air %) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 32,975 6,179 80,000 F Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 MI HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak). 26 OF 68 OF Outside Air 0 cfm Supply Fan 1,500 cfm 68 OF 69 OF 105 OF —� Heating Coil 105 OF i ROOM 68 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 112/78OF 75/62°F 77/62°F 55/54°F Outside Air 0 cfm Supply Fan Cooling Coil 55 / 54 OF 1,500 cfm ( --- / 47.3 % ROOMIS 75/62°F 75/62°F EnergyPro 6.1 by EnergySoft User Number. 6168 RunCode: 2014-05-23T14:20:46 ID: 05212014A Page 17 of 22 ROOM LOAD SUMMARY Project Name Date Codorniz Plan 4-2 (Right Half) 2013 Standards 512312014 System Name Floor Area HVAC 1,655 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible I Latent CFM Sensible Ground Floor Ground floor 1 552 11,598 848 552 11,598 848 300 11,741 Second Floor Second floor 1 1 4651 9,7711 956 465 9,7711 956 190 7,430 PAGE TOTAL TOTAL* 1,017 21,368 1,804 489 19,172 1,017 21,368 1,804 489 19,172 * Total includes ventilation load for zonal systems. EnergyPro 6.1 by EnergySoft User Number.- 6168 RunCode: 2014-05-23T14:20:46 /D: 05212014A Page 18 of 22 ROOM HEATING PEAK LOADS Project Name Codorniz Plan 4-2 (Right Half) 2013 Standards Date 512312014 ROOM INFORMATION DESIGN CONDITIONS Room Name Ground floor Floor Area 778.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF _ = = = = = = = = = = = = = = = = = = = = = = = = = = = 42 Btu/hr R-15 Wall w/1"EPS 842.0 0.0688 42 2,434 Alpine A770 Picture/Fixed 10.0 0.3200 42 134 Wood Door 24.0 0.5000 42 504 Alpine A272 Horiz Slider 147.0 0.3500 42 2,161 Alpine A172 Sldg Glass/Patio Door 60.0 0.3400 42 857 Slab -On -Grade perim = 131.0 0.7300 42 4,016 -R-15 Wall (W.15.2x4.16) 232.0 0.0950 18 397 Items shown with an asterisk (") denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 778 X Area another room 9.10 X 0.241 Height ACH Page Total / 60 J X AT 10,504 = 1,269 TOTAL HOURLY HEAT LOSS FOR ROOM 11,741 EnergyPro 6.1 by EnergySoft User Number. 6168 RunCode: 2014-05-23T14:20:46 ID: 05212014A Page 19 of 22 ROOM HEATING PEAK LOADS Project Name Codorniz Plan 4-2 (Right Half) 2013 Standards Date 512312014 ROOM INFORMATION DESIGN CONDITIONS Room Name Second floor Floor Area 877.0 ftZ Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT'F = = = = = = = c = = = = = = = = = = 42 Btu/hr R-15 Wall w/1 " EPS 930.8 0.0688 42 2,691 Alpine A770 Picture/Fixed 26.8 0.3200 42 360 Alpine A272 Horiz Slider 18.0 0.3500 42 265 Alpine A172 Sldg Glass/Patio Door 24.0 0.3400 42 343 Alpine A571 Single Hung 30.4 0.3500 42 447 R-22 Roof Attic 877.0 0.0410 42 1,510 *R-19 Floor No Crawlspace 435.0 0.0490 18 384 *R-0 Floor No Crawlspace 442.0 0.2380 0 0 Items shown with an asterisk (*) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 877 X Area another room 8.00 X 0.274 Height ACH Page Total / 60 ] X AT 5,999 = 1,431 TOTAL HOURLY HEAT LOSS FOR ROOM 7,430 EnergyPro 6.1 by EnergySoft User Number., 6168 RunCode: 2014-05-23T14:20:46 ID: 05212014A Page 20 of 22 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Codorniz Plan 4-2 (Right Half) 2013 Standards 7512312014 ROOM INFORMATION DESIGN CONDITIONS Room Name Ground floor Outdoor Dry Bulb Temperature 112 OF Floor Area 778.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-15 Wall w/1 "EPS (E) 114.0 X 0.0688 X 33.0 = 259 R-15 Wall w/1 " EPS (N) 342.0 X 0.0688 X 23.0 = 542 Wood Door (N) 24.0 X 0.5000 X 23.0 = 276 R-15 Wall w/1 " EPS (W) 186.0 X 0.0688 X 33.0 = 423 R-15 Wall w/1 " EPS (S) 200.0 X 0.0688 X 26.0 = 358 "R-15 Wall (W.15.2x4.16) 232.0 X 0.0950 X 25.0 = 551 X X = X X = X X = Page Total 2,408 Items shown with an asterisk () denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 2050 (E) 0.0 X 19.0 + 10.0 X 39.2 = 392 Window 8056 (N) 0.0 X 18.9 + 44.0 X 18.9 = 830 Window 8056 (W) 0.0 X 18.9 + 44.0 X 37.9 = 1,666 Window 3056 (S) 0.0 X 18.9 + 16.5 X 18.9 = 313 Window 9067 (W) 0.0 X 18.7 + 60.0 X 37.7 = 2,260 Window 5056 (S) 0.0 X 18.9 + 27.5 X 18.9 = 521 Window 3446 (S) 0.0 X 18.9 + 15.0 X 18.9 = 284 X + X = X + X = Page Total 6,26 Internal Gain Btu/hr Occupants 2 3 Occupants X 245 Btuh/occ. = 572 Equipment 778 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0.89 X 30.37 X 37 = 1,067 Air Sensible CFM ELA 4T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,598 Latent Gain Btu/hr Occupants 2 3 Occupants X 155 Btuh/occ. = 362 Infiltration: 4,771. X 0.89 X 30.37 X 0.00376 = 486 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 362 EnerqvPro 6.1 by EnerqvSoft User Number: 6168 RunCode: 2014-05-23T14:20:46 ID: 05212014A Page 21 of 22 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codorniz Plan 4-2 (Right Half) 2013 Standards 1 512312014 ROOM INFORMATION DESIGN CONDITIONS Room Name Second floor Outdoor Dry Bulb Temperature 112 OF Floor Area 877.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces R-15 Wall w/1 " EPS R-15 Wall w/1 " EPS R-15 Wall w/1 " EPS R-15 Wall w/1 " EPS R-22 Roof Attic I *R-19 Floor No Crawlspace *R-0 Floor No Crawlspace Orientation Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = 399.4 0.0688 23.0 101.0 0.0688 33.0 122.4 0.0688 33.0 308.0 0,0688 26.0 877.0 0.0410 56.0 435.0 0.0490 25.0 442.0 0.2380 0.0 Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window 205OF Window 4640 Window 1316x3 Window 13160 Door308OFR Window 1316x3 Window 2440 Window 2440 Window 3040 Orientation (E) (N) (140 (N) (N) (S) (S) (S) (S) Shaded Unshaded Btu/hr 632 229 278 551 2,014 533 0 1 4,2381 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 19.0 10.0 39.2 0.0 18.9 18.0 18.9 0.0 19.0 5.6 39.2 0.0 19.0 5.6 19.0 0.0 18.7 24.0 18.7 0.0 19.0 5.6 19.1 0.0 18.9 9.2 18.9 0.0 18.9 9.2 18.9 0.0 18.9 12.0 18.9 Page Total Btu/hr 392 340 220 106 448 107 174 174 2,1 Internal Gain Btu/hr Occupants 2•fi Occupants X 245 Btuh/occ. _ Equipment 877 Floor Area X 0.50 w/sgft 'a jZ o Infiltration: 1.064 X 0.89 X 34.23 X 37 = UJ P C Air Sensible CFM ELA AT W �<ranlz TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM J L" ry.- in 9,771 U-OU Latent Gain 100 � U Btu/hr Occupants 2 6 Occupants X I >15 B - SIM = 408 !-- ui Infiltration: 4,771 X 0.89 X 34.23 X 0.00376 = r� } 548 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4081 1 crflcs copy Title 24 Report CEC Approved 2013 Building Energy Efficiency Standards Job Name Codorniz Plan 4-4 Avenue 52 and Jefferson Street La Quinta, CA 92253 Prepared For RJT Homes - Codorniz, LLC Designer CITY OF LA QUINTA BUILDING & SAFETY APPROVED FOR CONSTRUCTION I9]�11�1►Ii.7/��W,,A' �� Prepared By Dave Bricker Energy Consultant 05222014A LEDSENERGY DRIVEN SOLUTIONS INC CAL TITLE 24 REPORTS NCI CERTIFIED AIR BALANCING P. O. Box 6705 LA QUINTA, CA 92248 760-541-9025 FAX 760-775-4723 CHEERS & CALCERTS CERTIFIED HERS RATER DAVEBRICKER@ENEBGYDS.NET CABEC CERTIFIED ENERGY ANALYST EDSENERGY DRIVEN SOLUTIONS INC Note to Plan Checker and Inspector Project Name: Codorniz 4-4 Job Number: 05222014A Project Designer: RJT Homes - Codorniz, LLC This project EXCEEDS 2013 Title 24 Standards by: • North Facing 6.5% • East Facing 12.6% • South Facing 6.5% • West Facing 2.3% HERS Measures include: • Verified < 12' of ducts in unconditioned space • Verified HVAC Fan efficacy • Verified HVAC Refrigerant Charge or Charge Indicator Display • Verified HVAC duct testing • Verified HVAC low leakage air handler • Verified HVAC 12 EER and 14 SEER • Verified IAQ Fan BUILDING ENERGY ANALYSIS REPORT PROJECT: Codorniz Plan 4-4 (Rev 2, 2013 Standards) Avenue 52 and Jefferson Street La Quinta, CA 92253 Project Designer: RJT Homes - Codorniz, LLC 1245 East University Drive Phoenix, AZ 85034 602-257-1656 Report Prepared by: Dave Bricker Energy Driven Solutions Inc P. O. Box 6705 La Quinta, CA 92248 760.541.9025 Job Number: 05222104A Date: 5/23/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 6.1 by Energ Soft User Number. 6168 ID: 05222104A I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 13 HVAC System Heating and Cooling Loads Summary 16 Room Load Summary 17 Room Heating Peak Loads 18 Room Cooling Peak Loads 20 EnergyPro 6.1 by EnergySoft Job Number: ID: 05222104A User Number: 6168 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 4-4 (Rev 2, 2013 Standards) Calculation Date/Time: 15:09, Fri, May 23, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz 4-4 run 3 (2013 Standards).xml CFI R-PRF-NCB-01 Page 1 of 10 GENERAL INFORMATION 01 Project Name Codorniz 4-4 (Rev 2, 2013 Standards) 02 Calculation Description Title 24 Analysis 03 Project Location Avenue 52 and Jefferson Street 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-1 a (532) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.1 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 1660 15 Number of Zones 2 16 Slab Area (FT2) 705 17 Number of Stories 2 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 Glazing Percentage (%) 13.5% Detailed help on using the CF-IR Certificate of Compliance Isfavailable via the Internet by either[j] scanning the QR code or,browsing to: / 1'rr�- http://www.title24energycode.org/t24help/cfl r.aspx J�6 ,t 0 r- ■ ❑ COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Crl-y OF LA E � F-� OIT T. BUI�-DI�fG ,�,�D APpFIO FOR OvSTRUCTlO►`I DATE_ BY Registration Number: 214-N0093954A-000000000-0000 Registration Date/Time: 2014-09-1513:44:58 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 CaICERTS inc. Report Generated at: 5/23/2014:3:18:51 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 4-4 (Rev 2, 2013 Standards) Calculation Date/Time: 15:09, Fri, May 23, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz 4-4 run 3 (2013 Standards).xml CF1R-PRF-NCB-01 Page 2 of 10 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 0.96 1.22 -0.26 -27.1% Space Cooling 92.48 88.06 4.42 4.8% IAQ Ventilation 1.05 1.05 0.00 0.0% Water Heating 15.06 12.14 2.92 19.4% PV Credit --- 0.00 0.00 ---- North Facing - TOTAL 109.55 102.47 7.08 6.5% Space Heating 0.96 0.81 0.15 15.6% Space Cooling 92.48 81.80 10.68 11.5% IAQ Ventilation 1.05 1.05 0.00 0.0% Water Heating 15.06 12.14 2.92 19.4% PV Credit --- 0.00 0.00 ---- East Facing - TOTAL 109.55 95.80 13.75 12.6% Space Heating Space Cooling 0.96r1+Ys-." ,---r 92A8 0.40: 88.88 ` 1 0.56 3.60 58.3% 3.9% IAQ Ventilation 1.05 1.05 `•., 0.00 0.0% r % 4 R .� Water Heating g .. - 12.14 ' rL:' (1 �tro 2.92 ° 19.4 /o PV Credit ---- 0.00 0.00 ---- South Facing - TOTAL 109.55 102.47 7.08 6.5% Space Heating 0.96 0.62 0.34 35.4% Space Cooling 92.48 93.22 -0.74 -0.8% IAQ Ventilation 1.05 1.05 0.00 0.0% Water Heating 15.06 12.14 2.92 19.4% PV Credit ---- 0.00 0.00 ---- West Facing - TOTAL 109.55 107.03 2.52 2.3% Registration Number: 214-N0093954A-000000000-0000 Registration Date/Time: 2014-09-15 13:44:58 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/23/2014:3:18:51 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-NCB-01 Project Name: Codorniz 4-4 (Rev 2, 2013 Standards) Calculation Date/Time: 15:09, Fri, May 23, 2014 Page 3 of 10 Calculation Description: Title 24 Analysis Input File Name: Codorniz 4-4 run 3 (2013 Standards).xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Number of Dwelling Number of Ventilation Number of Water Project Name Conditioned Floor Area (sft) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems Codorniz 4-4 (Rev 2, 2013 1660 1 2 2 0 1 Standards) ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Ground Floor Conditioned _ HVAC1 705 9.1 DHW Sys 1 Second Floor Conditioned. ►i HVAC1., ' l= 955' ' 8 DHW Sys 1 Registration Number: 214-N0093954A-000000000-0000 Registration Date/Time: 2014-09-15 13:44:58 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 Report Generated at: 5/23/2014:3:18:51 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 4-4 (Rev 2, 2013 Standards) Calculation Date/Time: 15:09, Fri, May 23, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz 4-4 run 3 (2013 Standards).xml CF1R-PRF-NCB-01 Page 4 of 10 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window Area (ftZ) Tilt(deg) Exterior Wall front N 11.7x10 Ground Floor R-15 Wall w/1 EPS 0 Front 117 13.5 90 Exterior Wall left E 1.5x10 Ground Floor R-15 Wall w/1 EPS 90 Left 15 0 90 Exterior Wall front N 11.8x10 Ground Floor R-15 Wall w/1 EPS 0 Front 118 27.5 90 Exterior Wall right W 7.5x10 Ground Floor R-15 Wall w/1 EPS 270 Right 75 16.5 90 Exterior Wall front N 7.7x10 Ground Floor R-15 Wall w/1 EPS 0 Front 77 33.3 90 Wall left W 16.3x10 Ground Floor R-15 Wall w/1 EPS 270 Right 163 45 90 Garage wall 2200 Ground Floor»Garage R-13 Wall 220 Exterior Wall left E 13.8x8 Second Floor R-15 Wall w/1 EPS 90 Left 110 24 90 Exterior Wall front N 6x8 Second Floor R-15 Wall w/1 EPS 0 Front 48 9.3 90 Exterior Wall left E 8.25x8 Second Floor R-15 Wall w/1 EPS 90 Left 66 9.3 90 Exterior Wall front N 44.5x8 Second Floor R-15 Wall w/1 EPS 0 Front 356 19.8 90 Exterior Wall right W 13x8 ,;,�oSecond Floor t.., �,�' �- +71R=15-Walltw/1-EP'Sp— e?70 Right 104 18 90 Exterior Wall rear S 7.7x8 1 Second Floor! i `' R-115 Wall w/1 PS " ;'` 180' Back 61.6 5.6 90 Exterior Wall right W 8.8x8 t Second Floor,r R-15 Wall w/1 EPS , 270 �^� �/^ /Right} 70 3 90 Roof '*Second Floor - R-22 Roof Attic y t"'` l 955 Floor over garage Second Floor»Garage R-19 Floor No Crawlspace 351 Exterior Wall rear S 23.5x9 Garage Garage Ext Wall 180 Back 212 0 90 Exterior Wall right W 20.3x9 Garage Garage Ext Wall 270 Right 183 0 90 Exterior Wall front N 2.5x9 Garage Garage Ext Wall 0 Front 23 0 90 Exterior Wall left E 20.3x9 Garage Garage Ext Wall 90 Left 183 0 90 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 2.99194 0.1 0.85 No No Registration Number: 214-N0093954A-000000000-0000 Registration Date/Time: 2014-09-1513:44:58 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/23/2014:3:18:51 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 4-4 (Rev 2, 2013 Standards) Calculation Date/Time: 15:09, Fri, May 23, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz 4-4 run 3 (2013 Standards).xml CF1R-PRF-NCB-01 Page 5 of 10 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height (ft) Width(ft ) Multiplie r Area (ft2) U- factor SHG C Exterior Shading Window 3046 Window Exterior Wall front N 11.7x10 (Front-0) --- ---- 1 13.5 0.35 0.32 Window 5056 Window Exterior Wall front N 11.8x10 (Front-0) ---- ---- 1 27.5 0.35 0.32 Window 3056SU Window Exterior Wall right W 7.5x10 (Right-270) --- ---- 1 16.5 0.35 0.32 Window 5080SL Window Exterior Wall front N 7.7x10 (Front-0) ---- ---- 1 33.3 0.35 0.32 Window 8056SL Window Wall left W 16.3x10 (Right-270) ---- --- 1 45.0 0.34 0.32 Door 308OFR Window Exterior Wall left E 13.8x8 (Left-90) ---- ---- 1 24.0 0.34 0.32 Window 2440 Window Exterior Wall front N 6x8 (Front-0) ---- ---- 1 9.3 0.32 0.34 Window 2440 2 Window Exterior Wall left E 8.25x8 (Left-90) ---- ---- 1 9.3 0.32 0.34 Window 2040 Window Exterior Wall front N 44.5x8 (Front-0) ---- ---- 1 8.0 0.32 0.34 Window 2040 Window Exterior Wall front N 44.5x8 (Front-0) ---- ---- 1 8.0 0.32 0.34 Window 1316 Window Exterior Wall front N 44.5x8 (Front-0) ---- ---- 1 1.9 0.32 0.34 Window 1316 2 Window Ff Exterior Wall front N 44.5x8 (Frontpj e ` ° ;'-- �. -- 1 1.9 0.32 0.34 Window 4640 Window '401�i r JExterior Wall right W 13x8 (Right=270) ---- t`' _ 1 18.0 0.35 0.32 Window 1316x3 Window 1\ ° // / Exterior Wall rear S 7.7x8_(Back=180) J ,) - �` ��;5 1 5.6 0.32 0.34 Window 2016 Window Exterior Wall right W 8.8x8 (Right-270) --- ---- 1 3.0 0.35 0.32 DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door308O Wall left W 16.300 24.0 0.50 Registration Number: 214-N0093954A-000000000-0000 Registration Date/Time:2014-09-15 13:44:58 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/23/2014:3:18:51 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 4-4 (Rev 2, 2013 Standards) Calculation Date/Time: 15:09, Fri, May 23, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz 4-4 run 3 (2013 Standards).xml CF1R-PRF-NCB-01 Page 6 of 10 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity. R 15 Sheathing/Insulation: - no sheathing/insul. - R-15 Wall w/1 EPS Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 Exterior Finish: R4 Synthetic Stucco Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: R 13 Sheathing/Insulation: - no sheathing/insul. - R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 Other Side Flnish: Gypsum Board + Attic Floor: - no attic floor - Cavity: R 22 Wood �.in/0� Sheathinglnsulation - no sheathing/insul. - R-22 Roof Attic Ceilings (below attic Framed Ceiling 2x4 @ 24 .C. ,�. R 22, �„ Inside Finish: Gypsum Board � l ;�.�^' j �,arL�- f�-;r,_yJ • Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - Cavity: - no insulation - Sheathing/Insulation: - no sheathing/insul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. Exterior Finish: 3 Coat Stucco SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab -on -Grade covered Ground Floor 219 12 None 0.8 No Slab -on -Grade exposed Ground Floor 486 47 None 0.8 No Slab -on -Grade Garage 470 44 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Instal lation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa NOT REQUIRED NOT REQUIRED NOT REQUIRED --- Registration Number: 214-N0093954A-000000000-0000 Registration Date/Time: 2014-09-1513:44:58 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/23/2014:3:18:51 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 4-4 (Rev 2, 2013 Standards) Calculation Date/Time: 15:09, Fri, May 23, 2014 Calculation Description: Title 24 Analysis Input File Name: Codorniz 4-4 run 3 (2013 Standards).xml CF1R-PRF-NCB-01 Page 7 of 10 WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Standard 1 0.0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 48 0.66 67000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping J Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw __—_,-,n/a.� n/a , �n/a�, n/a n/a HVAC SYSTEMS 01 102% t! f ` 03 ` . °. .,1,�/.' ?4.v„ 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC1 Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 1660 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 94 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 12 14 Cooling Component 1-hers-cool Registration Number: 214-N0093954A-000000000-0000 Registration Date/Time: 2014-09-15 13:44:58 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 Report Generated at: 5/23/2014:3:18:51 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 4-4 (Rev 2, 2013 Standards) Calculation Description: Title 24 Analysis Calculation Date/Time: 15:09, Fri, May 23, 2014 Input File Name: Codorniz 4-4 run 3 (2013 Standards).xml CF1 R-PRF-NCB-01 Page 8 of 10 HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Ducts located within the Specified Lower Air Distribution Air Distribution System 1 conditioned space (except < 12 Leakage Target 8 Conditioned Zone Conditioned Zone None System 1-hers-dist lineal ft) HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verriificati n F t D t Leakkage Target(%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required., t 1 6.0 j ! ;Required Not Required Not Required 1.0c-1 t , t . , 11, _-, .- " _"1 . . : N 'r W__ . .c d.-. `—e—, n L-fir U [ Y6_s/d HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 39 Exhaust 0 Required Registration Number: 214-N0093954A-000000000-0000 Registration Date/Time: 2014-09-1513:44:58 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-05072014-595 CaICERTS inc. Report Generated at: 5/23/2014:3:18:51 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-NCB-01 Project Name: Codorniz 4-4 (Rev 2, 2013 Standards) Calculation Description: Title 24 Analysis Calculation Date/Time: 15:09, Fri, May 23, 2014 Input File Name: Codorniz 4-4 run 3 (2013 Standards).xml COOLING VENTILATION NONE Registration Number: 214-No093954A-000000000-0000 Registration Date/Time: 2014-09-15 13:44:58 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-05072014-595 Page 9 of 10 CaICERTS inc. Report Generated at: 5/23/2014:3:18:51 PM CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Codorniz 4-4 (Rev 2, 2013 Standards) Calculation Description: Title 24 Analysis Calculation Date/Time: 15:09, Fri, May 23, 2014 Input File Name: Codorniz 4-4 run 3 (2013 Standards).xml CF1R-PRF-NCB-01 Page 10 of 10 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: VIW4 Wi-'We-ri David Bricker Company: Signature Date: Energy Driven Solutions, Inc. 2014-09-15 08:32:56 Address: CEA/HERS Certification Identification (If applicable): PO Box 6705 R08-06-207 City/State/Zip: Phone: La Quinta, CA 92248 760 541 9025 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligibleunderDivision 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified onjhis _Certificate of Compliance are consistent -,with the information provided on other applicable compliance documents, 9, worksheets, calculations, plans and specifications submittecI46 the enforcement agency for approval with ithis building permit application. Responsible Designer Name: ' s � r _err"' ResponsibleD'esigner Signature: C��c%v� Chad Meyer �.��/! " ,. a yer Company: Date Signed: RJT Homes 2014-09-15 13:44:58 Address: License: PO Box 810 NA City/State/Zip: Phone: La Quinta, CA 92253 760-564-6555 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-N0093954A-000000000-0000 Registration Date/Time: 2014-09-15 13:44:58 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-05072014-595 CaICERTS inc. Report Generated at: 5/23/2014:3:18:51 PM MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name Codorniz Plan 4-4 (Rev 2, 2013 Standards) Date 1512312014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- I R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 110.6 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling or equivalent U-factor. 150.0 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U-factor. * 150.0 d : Minimum R-19 insulation in raised wood -frame floor or equivalent U-factor. 150.0 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150.0 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150.0 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2c . §150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150.00)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150.0-B. §150.00)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150.0-13 and Equation 150.0-A. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. 150.0 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150.0 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 05222104A Page 13 of 22 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Codorniz Plan 4-4 (Rev 2,. 2013 Standards) 5/23/2014 §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §1.50.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0 m 7: Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150.0 m 10: Flexible ducts cannot have porous inner cores. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 110.4 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150.0 p : Residential pools stems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150.0(p). Residential Lighting Measures: §150.0(k)1 A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. 150.0 k 1C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c). §150.0(k)1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. 150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150.0(k). 150.0 k 2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 05222104A Page 14 of 22 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 WAR Project Name , Date Codorniz Plan 4-4 (Rev 2, 2013 Standards) 512312014 §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: ' At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or.less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. EnergyPro 6.1 by EnergySoft User Number: 6168 ID: 05222104A Page 15 of 22 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Codorniz Plan 4-4 (Rev 2, 2013 Standards) Date 5/23/2014 System Name HVAC Floor Area 1,660 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 874 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 80,000 18,405 1,856 353 13,856 Total Output (Btuh) 80,000 0 Output Btuh/s ft 48.2 348 218 Cooling System 0 0 Output perSystem 46,000 0 0 0 0 Total Output (Btuh) 46,000 2,233 1,856 -2,233 Total Output (Tons) 3•8 348 218 Total Output (Btuh/s ft) 27.7 Total Output s ft/Ton 433.0 1 21,334 12,058 Air System CFM perSystem 1,500 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,500 Carrier CA16NA048****A 33,000 6,357 80,000 Airflow (cfm/s ft) 0.90 Airflow (cfm/Ton) 391.3 Outside Air (%) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 33,000 6,357 80,000 Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 68 OF 69 OF 105 OF Outside Air — 0 cfm Supply Fan Heating Coil 1,500 cfm 68 OF 105 OF ROOM I 68 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 111/78OF 75/62°F Outside Air Ar 0 cfm 75/62°F 77/62°F 55/54°F Supply Fan Cooling Coil 55 / 54 OF 1,500 cfm 47.3 % ROOM p 75/62°F EnergyPro 6.1 by EnergySoft User Number. 6168 RunCode: 2014-05-23T15:26:56 ID: 05222104A Page 16 of 22 ROOM LOAD SUMMARY Project Name Date Codorniz Plan 4-4 (Rev 2, 2013 Standards) 5/23/2014 System Name Floor Area HVAC 1,660 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name - Mult. CFM Sensible Latent CFM Sensible I Latent CFM Sensible Ground Floor Ground floor 1 385 8,096 788 385 8,096 788 179 7,009 Second Floor Second floor 1 490 10,3091 1,068 490 10,3091 1,068 175 6,847 PAGE TOTAL TOTAL * 874 18,405 1,856 353 13,856 874 18,405 1,856 353 13,856 * Total includes ventilation load for zonal systems. EnergyPro 6.1 by EnergySoft User Number. 6168 RunCode: 2014-05-23T15:26:56 /D: 05222104A Page 17 of 22 ROOM HEATING PEAK LOADS Project Name Codorniz Plan 4-4 (Rev 2, 2013 Standards) 7512312014 ROOM INFORMATION DESIGN CONDITIONS Room Name Ground floor Floor Area 705.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = = = = = = = = = = = = = = = = = = = = = = = 42 Btu/hr R-15 Wall w/1"EPS 405.2 0.0688 42 1,172 Alpine A272 Horiz Slider 90.8 0.3500 42 1,335 Alpine A172 Sldg Glass/Patio Door 45.0 0.3400 42 643 Wood Door 24.0 0.5000 42 504 Slab -On -Grade perim = 59.0 0.7300 42 1,809 'R-13 Wall 220.0 0.1020 18 404 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 705 X Area another room 9.10 X 0.239 Height ACH Page Total / 60 ] X AT 5,866 c 1,144 TOTAL HOURLY HEAT LOSS FOR ROOM 7,009 EnergyPro 6.1 by EnergySoft User Number., 6168 RunCode: 2014-05-23T15:26:56 ID: 05222104A Page 18 of 22 ROOM HEATING PEAK LOADS Project Name Codorniz Plan 4-4 (Rev 2, 2013 Standards) Date 512312014 ROOM INFORMATION DESIGN CONDITIONS Room Name Second floor Floor Area 955.0 ft2 Indoor Dry Bulb Temperature 68 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = = = = = = = = = = = = = = = = = = = = = 42 Btu/hr R-15 Wall w/1 " EPS 726.6 0.0688 42 2,101 Alpine A172 Sldg Glass/Patio Door 24.0 0.3400 42 343 Alpine A770 Picture/Fixed 44.0 0.3200 42 591 Alpine A272 Horiz Slider 21.0 0.3500 42 309 R-22 Roof Attic 955.0 0.0410 42 1,645 *R-0 Floor No Crawlspace 604.0 0.2380 0 0 *R-19 Floor No Craw/space 351.0 0.0490 18 310 Items shown with an asterisk (*) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 955 X Area another room 8.00 X 0.272 Height ACH Page Total / 60 ] X AT 5,298 c 1,549 TOTAL HOURLY HEAT LOSS FOR ROOM 6,847 EnergyPro 6.1 by EnergySoft User Number: 6168 Run Code: 2014-05-23T15:26:56 ID: 05222104A Page 19 of 22 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codorniz Plan 4-4 (Rev 2, 2013 Standards) 512312014 ROOM INFORMATION DESIGN CONDITIONS Room Name Ground floor Outdoor Dry Bulb Temperature III OF Floor Area 705.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Dailv Ranae: 34 OF Opaque Surfaces R-15 Wall w/1 " EPS R-15 Wall w/1 " EPS R-15 Wall w/1 " EPS Wood Door *R-13 Wall Orientation Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = 237.7 0.0688 23.0 15.0 0.0688 33.0 152.5 0.0688 33.0 24.0 0.5000 33.0 220.0 0.1020 25.0 Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window 3046 Window 5056 Window 3056SL' Window 5080SL Window 8056SL Orientation (N) (N) (M (N) (VV) Shaded Unshaded Btu/hr 376 1 5611 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 19.0 13.5 19.0 0.0 19.0 27.5 19.0 0.0 19.0 16.5 38.0 0.0 19.0 33.3 19.0 0.0 18.8 45.0 37.8 Page Total 1,714 Btu/hr 256 521 626 631 1,700 3, Internal Gain Btu/hr Occupants 21 Occupants X 245 Btuh/occ. = 518 Equipment 705 Floor Area X 0.50 w/sgft = 1,203 Infiltration: 1.064 X 0.88 X 27.36 X 36 = 926 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,0961 Latent Gain Btu/hr Occupants 21 Occupants X 155 Btuh/occ. = 328 Infiltration: 4,771 X 0.88 X 27.36 X 0.00399 = 460 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3281 EnergyPro 6.1 by EnergySoft User Number: 6168 RunCode: 2014-05-23T15:26:56 ID: 05222104A Page 20 of 221 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codorniz Plan 4-4 (Rev 2, 2013 Standards) 1 512312014 ROOM INFORMATION DESIGN CONDITIONS Room Name Second floor Outdoor Dry Bulb Temperature 111 OF Floor Area 955.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Dailv Ranae: 34 OF Opaque Surfaces R-15 Wall w/1 " EPS R-15 Wall w/1 " EPS R-15 Wall w/1 " EPS R-15 Wall w/1 " EPS R-22 Roof Attic *R-0 Floor No Crawlspace *R-19 Floor No Crawlspace Orientation Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = 142.7 0.0688 33.0 374.9 0.0688 23.0 153.0 0.0688 33.0 56.0 0.0688 26.0 955.0 0.0410 56.0 604.0 0.2380 0.0 351.0 0.0490 25.0 Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Door308OFR Window 2440 Window 2440 Window 2040 Window 2040 Window 1316 Window 1316 Window 4640 Window 1316x3 Orientation (E) (N) (E) (N) (N) (N) (N) (VV) (S) Btu/hr 324 594 348 100 2,193 0 430 1 3,9881 Shaded Area X X X X X X X X X GLF + + + + + + + + + Unshaded Area X X X X X X X X X GLF = = = = = = = = = 0.0 18.8 24.0 37.8 0.0 19.2 9.3 19.2 0.0 19.2 9.3 39.3 0.0 19.2 8.0 19.2 0.0 19.2 8.0 19.2 0.0 19.2 1.9 19.2 0.0 19.2 1.9 19.2 0.0 19.0 18.0 38.0 0.0 19.2 5.6 19.2 Page Total Btu/hr 906 178 366 153 153 36 36 683 1 2,6211 Internal Gain Btu/hr Occupants 2 9 Occupants X 245 Btuh/occ. _ Equipment 955 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0.88 X 37.06 X 36 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,309 Latent Gain Btu/hr Occupants 2 9 Occupants X 155 Btuh/occ. = 444 Infiltration: 4,771 X 0.88 X 37.06 X 0.00399 = 624 Air Sensible CFM ELA pW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 444 1 EnergyPro 6.1 by EnergySoft User Number: 6168 RunCode: 2014-05-23T15:26:56 ID: 05222104A Page 21 of 22 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Codorniz Plan 4-4 (Rev 2, 2013 Standards) 512312014 ROOM INFORMATION DESIGN CONDITIONS Room Name Second floor Outdoor Dry Bulb Temperature III OF Floor Area 955.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 2016 (W) 0.0 X 19.0 + 3.0 X 38.0 = 114 X + X = X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 114 Internal Gain Btu/hr Occupants 2 9 Occupants X 245 Bt_uh/occ. = 702 Equipment 955 Floor Area X 0.50 w/sgft = 1,630 Infiltration: 1.064 X 0.88 X 37.06 X 36 = 1 J 1,255 Air Sensible CFM ELA AT { LLJ LL > TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 3 C/) 10,309 Latent Gain oz$r 0 29 Occupants X 5 ��JOccu Btu/hr 444 ants t= J Infiltration: 4,771 X 0.88 X 37.06 X 0.00399 = U Sensible CFM ELAOW IMAir TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 444 EnergyPro 6.1 by EnergySoft User Number: 6168 RunCode: 2014-05-23T15:26:56 ID: 05222104A Page 22 of 22