Mediterra Apartments TR 27131 - Geotechnical InvestigationGEOTECHNICAL INVESTIGATION
PROPOSED BIG HOUSE APARTMENT COMPLEX
PARCEL 3 OF TRACT 2713i
NEC WASHINGTON STREET & DARBY ROAD
LA QUINTA, CALIFORNIA
-Prepared By-
Sladden Engineering
39-725 Garand Lane, Suite G
Palm Desert, California 92211
(760) 772-3893 .
Sladden Engineering
Sladden _Engineering
6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369
39-725 Garand Ln., Suite G, Palm Desert, CA 92211 (760) 772-3893 Fax (760) 772-3895
October 28, 2003
White Company Residential
c/o Saxon Engineering Services
1030 Calle Sombra, Suite A2
San Clemente, California 92673
Attention: Mr. Kurt Saxon
Project: Proposed Big House Apartments
NEC Washington Street and Darby Road
La Quinta, California
Subject: Geotechnical Investigation
Project No. 544-3432
03-10-695
Presented herewith is the report of our Geotechnical Investigation conducted at the site of the
proposed Big House Apartment Complex to be located on the northeast corner of Washington Street
and Darby Road in the City of La Quinta, California. The investigation was- performed in order to
provide recommendations for site preparation and to assist in foundation design for the proposed
residential structures.
This report presents the results of our field investigation and laboratory testing along with
conclusions and recommendations for foundation design and site preparation. This report completes
our original scope of services as understood in our proposal dated September 11, 2003.
We appreciate the opportunity to provide service to you on this project. If you have any questions
regarding this report, please contact the undersigned
Respectfully submitted,
SLADDEN ENGINEERING
Brett L. Anderson
Principal Engineer
SERIpc
Copies: 6/Saxon Engineering Services
Sladden Engineering
GEOTECHNICAL INVESTIGATION
PROPOSED BIG HOUSE APARTMENT COMPLEX
PARCEL 3 OF TRACT 27131
NEC WASHINGTON STREET & DARBY ROAD
LA QUINTA, CALIFORNIA
October 28, 2003
TABLE OF CONTENTS
INTRODUCTION....................................................................................................................... 1
SCOPEOF WORK..................................................................................................................... 1
PROJECT DESCRIPTION...................................:.................................................................... 1
SUBSURFACE CONDITIONS................................................................................................. 2
CONCLUSIONS AND RECOMMENDATIONS...................................................................... 2
FoundationDesign.............................................................................................................. 3
Settlements.......................................................................................................................... 3
LateralDesign..................................................................................................................... 3
RetainingWalls................................................................................................................... 4
ExpansiveSoils...................................................................................:................................ 4
Concrete Slabs-on-Grade..................................................................................................... 4
SolubleSulfates................................................................................................................... 4
Shrinkage and Subsidence.......................................................... :.................... .................... 4
GeneralSite Grading............................................:..........................................:................... 5
1. Clearing and Grubbing............................................................................................. 5
2. Preparation of Building Areas................................................................................. 5
3. Preparation of Surfaces to Receive Compacted Fill ................................................. 5
4. Placement of Compacted Fill .................................................................................... 5
5. Preparation of Slab and Pavement Areas..............................................:................. 6
6. Testing and Inspection.............................................................................................. 6
GENERAL............... :...................................................................................................................
APPENDIX A - Site Plan and Boring Logs
Field Exploration
APPENDIX B - Laboratory Testing
Laboratory Test Results
APPENDIX C - 1997 UBC Seismic Design Criteria
Sladden Engineering
October 28, 2003
-1-
Project No. 544-3432
03-10-695
INTRODUCTION
This report presents the results of our Geotechnical Investigation performed in order to provide
recommendations for the design and construction of the foundations for the proposed apartment
complex. The project site is located on the northeast corner of Washington Street and Darby Road in
the City of La Quinta, California. The preliminary plans indicate that the proposed development
will consist of 18 apartment buildings and various related site improvements. The associated site
improvements will include paved roadways, concrete driveways, concrete walkways, various
underground! utilities, and landscape areas.
f
SCOPE OF WORK
The purpose i of our investigation was to determine certain engineering characteristics of the near
surface soils on the site in order to develop recommendations for foundation design and site
preparation. j Our investigation included field exploration, laboratory testing, engineering analysis
and the preparation of this report. Evaluation of environmental issues or hazardous wastes was not
within the scope of services provided. Our investigation was performed in accordance with
contemporary geotechnical engineering principles and practice. We make no other warranty, either
express or implied.
I
PROJECT DESCRIPTION
The project site is located on the northeast corner of the future alignment of Palm Royale Drive and
Washington Street in the City of La Quinta, California. The preliminary plans indicate that the
project will include 18 multi -unit apartment buildings. It is our understanding that the proposed
apartment buildings will be of relatively lightweight wood -frame construction and will be supported
by conventional shallow spread footings and concrete slabs on grade. The associated improvements
willinclude concrete walkways and driveways, landscape areas and various underground utilities.
The project site is presently vacant and the ground surface is covered with scattered desert brush,
short grass, weeds and minor debris. The site is relatively level throughout but distinct agricultural
levels provide topographical relief of up to 13 feet between the western and eastern portions of the
site. The majority .of the properties surrounding the site are presently vacant. There are
underground, and overhead utilities along the existing streets and may transect the site.
Based upon I our understanding of the proposed construction and our previous experience with
lightweight wood -frame structures, we expect that isolated column loads will be less than 30 kips
and wall loading will be less than 2:0 kips per linear foot. Grading is expected to include substantial
cuts and fills to match the nearby elevations and to construct level building pads. This does not
include removal and/or recompaction of the loose surface soils the primary foundation bearing soils
within the building areas. If the anticipated foundation loading or site grading varies substantially
from that assumed the recommendations included in this report should be reevaluated.
Sladden Engineering
October 28, 2003 -2- Project No. 544-3432
03-10-695
SUBSURFACE CONDITIONS
The site soils were determined to consist primarily of native fine-grained windblown sands. The
native windblown sands were fairly uniform in composition throughout the site and the depth of our
borings. The windblown sands were typically slightly silty and contained less than 15 percent fines
(clay and silt sized particles).
In general, the site soils appear somewhat loose near the surface but sampler penetration resistance
(as measured by field blow counts) indicates that density within the native soils underlying the site
generally increases with depth. The site soils were found to be dry throughout the depth of our .
exploratory borings.
Laboratory classification testing indicates that the near surface soils consist primarily of fine-
grained windblown sands. Expansion testing indicates that the surface soils are non -expansive and
fall within the "very low" expansion category in accordance with the Uniform Building Code
classification system. The loose and dry conditions suggest that the near surface soils may be
susceptible to detrimental settlements due to the anticipated foundation loading and the
introduction of water.
Groundwater was not encountered within our borings but is expected to be in excess of 100 feet .
below the existing ground surface in the vicinity of the site. Groundwater should not be a factor in
foundation design or construction.
CONCLUSIONS AND RECOMMENDATIONS
Based upon our field and laboratory investigation, it is our opinion that the proposed apartment
complex is feasible from a soil mechanic's perspective provided that the recommendations included in
this report are considered in building foundation design and site preparation. Due to the somewhat
loose and potentially compressible condition of some of the near surface soils, remedial grading
including overexcavation and/or watering and recompaction is recommended for the proposed
building areas. We recommend that remedial grading within the proposed building areas include
overexcavation and/or extensive site watering and recompaction of the primary foundation bearing
soils in order to provide a uniform mat of compacted soils beneath the building foundations. Specific
recommendations for site preparation are presented in the Site Grading section of this report.
Groundwater was not encountered within our borings and groundwater is expected to be in excess of
100 feet below the existing ground surface in the vicinity of the site. Due to the depth to
groundwater, specific liquefaction analyses. were not performed. Based upon the depth to
groundwater, the potential for liquefaction and the related surficial affects of liquefaction impacting
the site are considered negligible.
The site is located within an active seismic area of Southern California within approximately 7.9
kilometers of the San Andreas fault system.. Strong ground motion resulting from earthquake
activity along the nearby San Andreas or San Jacinto fault systems is likely to impact the site during
the anticipated lifetime of the structures. Structures should be designed by professionals familiar
with the site's geologic and seismic setting. As a minimum, structure design should conform with
Uniform Building Code (UBC) requirements for Seismic Zone 4. Pertinent seismic design
parameters as included within the 1997 UBC are summarized in Appendix C.
Sladden Engineering
October 28, 2003 -3- Project No. 544-3432
03-10-695
Caving did occur within each of our exploratory borings and the surface soils will be susceptible to
caving within deeper excavations. All excavations should be constructed in accordance with the
normal CalOSHA excavation criteria. On. the basis of our observations of the materials encountered,
we anticipate that the. subsoils will conform to those described by CalOSHA as Type C. Soil
conditions should be verified during construction by a "Competent person" employed by the
Contractor.
The surface soils encountered during our investigation were found to be non -expansive. Laboratory
testing indicated an Expansion Index of 0 that corresponds with the "very low" expansion category in
accordance with UBC Standard 18-2. If imported soils are to be used during grading, they should
have an Expansion Index of less than 20.
The following recommendations present more detailed design criteria that have been developed on
the basis of our field and laboratory investigation.
Foundation Design: The results of our investigation indicate that either conventional
shallow continuous footings or isolated pad footings that are supported upon properly
recompacted soils may be expected to provide satisfactory support for the proposed
structures. Recompaction should be performed as described in the Site Grading Section of
this report.
Footings should extend at least 12 inches beneath lowest adjacent grade. Isolated square or
rectangular footings at least 2 feet square may be designed using an allowable bearing value
of 1800 pounds per square foot. Continuous footings at least 12 inches wide may be designed
using an allowable bearing value of 1500 pounds per square foot. Allowable increases of 200
psf for each additional 1 foot of width and 250 psf for each additional 6 inches of depth may
be utilized if desired. The maximum allowable bearing pressure should be 2500 psf. The
allowable bearing pressures are for dead and frequently applied live loads and may be
increased by 1/3 to resist wind, seismic or other transient loading.
The recommendations made in the preceding paragraphs are based on the assumption that
all footings will be supported by properly compacted soil. All grading shall be performed
under the testing and inspection of the Soils Engineer or his representative. Prior to the
placement of concrete, we recommend that the footing excavations be inspected in order to.
verify that they extend into compacted soil and are free of loose and disturbed materials.
Settlements: Settlements may result from the anticipated foundation loads. These
estimated ultimate settlements are calculated to be a maximum of 1 inch when using the
recommended bearing values. As a practical matter, differential settlements between
footings can be assumed as one-half of the total settlement.
Lateral Design: Resistance to lateral loads can be provided by a combination of friction
acting at the base of the slabs or foundations and passive earth pressure along the sides of
the foundations. A coefficient of friction of 0.45 between soil and concrete may be used with
dead load forces only. A passive earth pressure of 300 pounds per square foot, per foot of
depth, may be used for the sides of footings that are placed against properly compacted
native soils.
Passive earth pressure should be ignored within the upper 1 foot except where confined (such
as beneath a floor slab). When used in combination, either the passive resistance or the
coefficient of friction should be reduced by one-third.
Sladden Engineering
October 28, 2003
i ..! ' -4- Project No. 544-3432
03-10-695
Retaining Walls: Retaining walls may be required to accomplish the proposed construction.
Cantilever retaining walls may be designed using "active" pressures. Active pressures may
be estimated using an equivalent fluid weight of 35 pcf for native backfill soils with level
free -draining backfill conditions.
For walls that are restrained, "at rest" pressures should be utilized in design. At rest
pressures may be estimated using an equivalent fluid weight of 55 pcf for native backfill soils
with level free -draining backfill conditions.
Expansive Soils: Due to the prominence of non -expansive soils on the site, special expansive
soil design criteria should not be necessary for the design of foundations and concrete slabs -
on -grade. Final foundation and slab design criteria should be established by the Structural
Engineer.
Concrete Slabs -on -Grade: All surfaces to receive concrete slabs -on -grade should be underlain
by recompacted soils as described in the Site Grading Section of this report. Where `slabs are
to receive moisture sensitive floor coverings or where dampness of the floor slab is not
desired, we recommend the use of an appropriate vapor barrier. Vapor barriers should be
protected by sand in order to reduce the possibility of puncture and to aid in obtaining
uniform concrete curing.
Reinforcement of slabs -on -grade in order to resist expansive soil pressures may not be
required however, reinforcement will have a beneficial effect in containing cracking due to
concrete shrinkage. Temperature and 'shrinkage related cracking should be anticipated in
all concrete slabs -on -grade. Slab reinforcement and the spacing of control joints should be
determined by the Structural Engineer.
Soluble Sulfates: The soluble sulfate concentrations of the surface soils was determined to be
74 parts per million (ppm). This is within the usual allowable limits for the use of Type II
cement and the use of Type V cement or .special sulfate resistant concrete mixes should not
be necessary.
Shrinkage and Subsidence: Volumetric shrinkage of the material that is excavated and
replaced as controlled compacted fill should be anticipated. We estimate that this shrinkage
could vary from 15 to 20 percent. Subsidence of the surfaces that are scarified and
compacted should be between. 0.1 and 0.2 tenths of a foot. Shrinkage and subsidence will
vary depending upon the type of equipment used, the moisture content of the soil at the time
,of grading and the actual degree of compaction attained.,
These values for shrinkage and subsidence are exclusive of losses that will occur due to the
stripping of the organic material from the site, the removal of deleterious materials and the
removal of debris, trees and other subsurface obstructions.
Sladden Engineering
October 28, 2003 -5' Project No. 544-3432
03-10-695
General Site Grading: All. grading should be performed in accordance with the grading
ordinance of the City of La Quinta, California. The following recommendations have been
developed on the basis of our field and laboratory testing:
Clearing and Grubbing: Proper clearing of any existing vegetation, associated root
systems, foundations or slabs, and ,debris willbe very important. All surfaces to
receive compacted fill should be cleared of roots, vegetation, debris, and other
unsuitable materials that should be removed from the site. Soils that are disturbed
due to the removal of the surface vegetation and debris should be replaced as
controlled compacted fill under the direction of the Soils Engineer.,
2. Preparation of Building Area: In order to provide firm and uniform bearing
conditions, we recommend thorough site watering and recompaction of the near
surface native soils throughout the building and foundation areas. The building
areas should be watered so that near 'optimum moisture content is attained to a
depth of at least 3 feet below existing grade or 3 feet below the bottom of the footings,
whichever is deeper. The exposed surface should then be compacted with heavy
equipment so that a� minimum of 90 percent relative compaction is attained to a
depth of at least 2 feet below existing grade or 2 feet below the bottom of the footings,
whichever is deeper. Fill material may then be placed as recommended in Item 4
below. If the recommended depth of compaction cannot be attained in this manner,
overexcavation may be necessary.
. 3. Preparation of Surfaces to Receive Compacted Fill: Other areas to receive compacted
fill should be brought to near optimum moisture content and compacted to a
minimum of 90 percent relative compaction.
4. Placement of Compacted Fill: Fill materials consisting of on -site soils or approved
imported granular soils, should be spread in thin lifts, and compacted at near
optimum moisture content to a minimum of 90 percent relative compaction.
Imported material shall have an Expansion Index not exceeding 20. The contractor
shall notify the Soils Engineer at least 48 hours in advance of importing soils in order
to provide sufficient time for the evaluation of proposed import materials.
The contractor shall be responsible for delivering material to the site that complies
With the project specifications. Approval by the Soils Engineer will be based upon
material delivered to the site .and not the preliminary evaluation of import sources.
Our observations of the material encountered. during our investigation indicate that
compaction will be most readily obtained by means of heavy rubber -wheeled
equipment and/or vibratory compactors. At the time of our investigation, the subsoils
were found to be very dry. A more uniform and near optimum moisture content
should be maintained during recompaction and fill placement.
Sladden Engineering.
October 28,-2003 6 Project No. 544-3432
03-10-695
5. Preparation of .Slab and Paving Areas: _ All surfaces to receive asphalt concrete
paving or concrete slabs -on -grade should be underlain by a minimum compacted fill
thickness of 12 inches: This may be accomplished by a combination of scarification
and recompaction of the surface soils and placement of the fill material as controlled
compacted fill. Compaction of the slab and pavement areas should be to a minimum
of 90 percent relative compaction. .
6. Testing and Inspection: During grading tests and observations should be performed
by the Soils Engineer or his representative in order to verify that the grading is being
performed in accordance with the project specifications. Field density testing shall
be performed in, accordance with acceptable ASTM test methods. The minimum
acceptable degree of compaction should be 90 percent of the maximum dry density as
obtained by the ASTM D1557-91 test method. Where testing indicates insufficient
density, additional compactive effort shall be applieduntil retesting indicates
satisfactory compaction.
The findings and recommendations presented in this report are based upon an interpolation of the
`soil conditions between the exploratory boring locations and extrapolation of these conditions,
throughout the proposed building area. Should conditions encountered during grading appear
different than those indicated in this report, this office should be notified.
This report is considered to be applicable for use by White Company Residential for the specific site
and project described herein. The use of this report by other parties or for other projects is not
authorized. The recommendations of this report are contingent upon monitoring of the grading
operation by a representative of Sladden Engineering. All recommendations are considered to be
tentative pending our review of the grading operation and additional testing, if. indicated. If others
are employed to perform any soil testing, this office should be notified prior to such testing in order
to coordinate any required site visits by our representative and to assure indemnification of Sladden
Engineering.
Our investigation was conducted prior to the completion of plans for the project. We recommend that
a pre -job 'conference be held on. the site prior to the initiation of site grading. The purpose of this
meeting will be to assure a complete understanding of the recommendations presented in this report
as they apply to the actual grading performed.
Sladden Engineering
APPENDIX A
Site Plan
Boring Logs
Sadden Engineering
APPENDIX A
FIELD EXPLORATION
For our field investigation 9 exploratory borings were excavated on September 23, 2003, using a
truck mounted Mobile B-61 drilling rig and hollow -stem augers. The approximate exploratory boring
locations are indicated on the site plan included in this appendix. Boring logs are included in this
appendix.
Representative undisturbed samples were obtained within our borings by driving a thin -walled steel
penetration sampler (California split spoon sampler) or a Standard Penetration Test (SPT) sampler
with a 140 pound hammer dropping approximately 30 inches (ASTM D1586). The number of blows
required to drive the samplers 18 inches was recorded in 6-inch increments and blowcounts are
indicated on the boring logs.
The California samplers are 3.0 inches in diameter, carrying brass sample rings having inner
diameters of 2.5 inches. The standard penetration samplers are 2.0 inches in diameter with an inner .
diameter of 1.5 inches. Undisturbed samples were removed from the sampler and placed in moisture
sealed containers in order to preserve the natural soil moisture content.. Bulk samples were obtained
from the excavation spoils and samples were then transported to our laboratory, for further
observations and testing.
J
Sladden Engineering
v
qK DARBY ROAD
PA M
3 Z
3
FRED WARING DR/ VE EMERALD
PAWAT
SIM
IjVThTCITY OFL.44?(1MT4 COUNTY OjPRfVZRSfDZ.ST.4Tropc,4LIFoRKl,4
PR�LI�LIINARY SITS' PZ-4yV.
PARCEL 3 OF TRACT -97131
8
4L
ell
all
----------- ------
.. ......... ...... . .
North Approximate Boring Locations
Doi
Proposed Big House Apartments / Parcel 3.of Tract 27131
NEC Washington Street & Darby Road / La Quinta, California
Date: 9-23-03
orine
No. 1 Job No.: 544-3432.
P.
o
y
DESCRIPTION
q
o
a
REMARKS
o
_
-
Sand: Grey, -fine grained
SP
5
6/8/1,2
" "
"
102
0.5
---
4% passing #200
10
10/16/24
---
0:5
- -
5% passing #200 .
15
_
17/22/32
102
0.5
---
6% passing #200
20
13/21/30
Sand: Brown,
SP/SM
___
0 .5
_
o
11 /o passing #200
_
slightly silty, fine grained
25
12/12/13
Sand: Grey, fine grained
SP
---
0•5
---
7% passing #200
30
_
12/16/23
Sand: Brown,
SP/SM
---
0
---
10% passing #200
"
slightly silty; fine grained
35
18/25/30
" "
---
0.5
---
10% passing #200
40
19/19/27
Sand: Grey, fine grained
SP
---
0.58
---
5% passing #200
as
14/17/21
Sand: Brown,
SP/SM
--
-0.5
---
9% passing #200
_
slightly silty, fine grained
so
14/22/35
Sand: Grey, fine grained
SP
---
0.5
---
5% passing #200
-Recovered Sample
Total Depth = 51.5'
_
Disturbed Sam le
® p
Note: The stratification lines
No Bedrock
No Groundwater
ss
represent the approximate
mStandard Penetration
boundaries between the soil types;
Sample
the transitions may be gradual.
Proposed Big House Apartments / Parcel 3 of Tract 27131 -
NEC Washington Street & Darby Road / La Quinta, California
Date: 9-23-03 Borine No.
2 Job No.: 544-3432
y
y
DESCRIPTION
F
A
o
a
REMARKS
,mow
it
A�
rn
U
Q"1
U
_
Sand: Grey, fine grained
SP .
s
5/7/9
"
---
0.5
-
5% passing #200
10
_ "
7/14/19
Sand: Brown,
SP/SM
---
0.5
-
10% passing.#200
slightly silty, fine grained
15
-
10/12/21
100
1.0
---
14% passing #200
20
Silty Sand: Grey brown,
SM
8/12/17
fine grained
105
0.5
---
2 1 % passing #200
-
Total Depth'= 21.5'
-.
- Recovered Sample
No Bedrock
® Disturbed Sample
No Groundwater
25
30
35
40
i
45
50'
Note: The stratification lines
represent the approximate
55
boundaries between the soil types;
the transitions may be gradual.
Proposed Big House Apartments / Parcel 3 of Tract 27131
NEC Washington Street & Darby Road / La Quinta, California
Date: 9-23-03 Borin No.
3 Job No.: 544-3432
y
A
DESCRIPTION
q
c
REMARKS
A�
ri
U
W
ri
a
0
-
Sand: Brown,
SP/SM
-
slightly silty, fine grained
-
s
-
4/5/7
" "
"
---
0.5
,
---
8% passing #200
10
_ "
7/8/14
"
---
0.5
---
8% passing #200
15
8/16/20
103
0.5 ,
---
10% passing #200
20
9/12/20
---
0.5
---
8% passing #200
-
Recovered Sample
P
Total Depth = 21.5'
No Bedrock
-
® Disturbed Sample
No. Groundwater
25
30
35
40
`
45
50
Note: The stratification lines
represent the approximate
55
boundaries between the soil types;
the transitions may be gradual
Proposed Big House Apartments / Parce13 of Tract 27131
NEC Washington Street &.Darby Road / La Quinta, California.
Date: 9-23-03 BorinE, No.
4 Job No.: 544-3432
DESCRIPTION-
A
o
�,
REMARKS
°
Sand: Brown,
SP/S
,
slightly silty, fine grained
s
7/11/16
"
108
0:5
---
12% passing #200
10
-X
6/8/12
" "
"
- '
---
---
Unrecovered sample due to tree root
15
10/16/19
Sand: Grey, fine grained
SP
104
0.5
---
5% passing #200
-
-
7/12/15
" "
---
0.5
---
6%o passing #200
P g
Recovered Sample
Total Depth = 21.5'
-
p
No Bedrock
-
D;;�j Disturbed Sample
No Groundwater
25
30
35
v
40
45
50
Note: The stratification lines
represent the approximate
55
boundaries between the soil types;
the transitions may be gradual.
20
Proposed Big House Apartments / Parcel 3' of Tract 21131
NEC Washington Street,& Darby Road / La Quinta, California
Date: 9-23-03 . Borin2 No.
6 Job No.: 544-3432
o
°
DESCRIPTION
q
o
REMARKS
•�
U
C4
rig
�D a'
c
o U
°
Sand: Brown,
SP/SM
-
slightly silty, fine grained
5
10/10/13
"
100
0.5
---
12% passing #200
10
-
6/10/16
"
99
0.5
9% passing #200
15
-
6/7/11
---
1.0
---
15% passing #200
20
11/16/28
" .
"
108
0.5
---
7% passing #200
-
Sample
Recovered S
Total Depth = 21.5' "
p
No Bedrock
=
C5� Disturbed Sample
No Groundwater
25
30.
-
35
40
45
50
Note: The stratification lines
represent the approximate ,
55
boundaries between the soil types;
the transitions may be gradual.
Proposed Big House Apartments / Parcel 3 of Tract 27131
NEC Washington Street & Darby Road / La Quinta, California
Date: 9-23-03 Borin No.
7 Job No.: 544-3432
y
DESCRIPTION
q
o
REMARKS
ca °
v
Sand: Brown,
slightly silty, fine grained
SP/SM
5
11/16/18
105
0.5
---
12% passing #200
10
7/14/141
102
1 0.5
1 11%passing #200
-
-
-
�5
- Recovered Sample
Total Depth = 11.5'
No Bedrock
No Groundwater
20
25
30
35
.40
45
50
Note: The stratification lines
represent the approximate
55
boundaries between the soil types;
the transitions may be gradual.
Proposed Big House Apartments / Parcel 3 of Tract.27131 ,
NEC Washington Street & Darby Road / La Quinta, California
Dater 9-23-03 Born
No.
8 Job No.: 544-3432
i
a+
0
y
DESCRIPTION.
•o
REMARKS,
d
A •�,
rn
V
PQ
r°
� 3
0
o U
,
0
-
Sand: Brown,
SP/SM
-
slightly silty, fine grained
s
8/16/20
103
0.5
---
9% passing #200
10
_
14/18/28
° "
"
106
0.5
10% passing #200
s
15/18/29
110
0.5
---
11 % passing #200
20
:16/19/20
"
101
0.5
---
12% passing #200
-
Total Depth = 21.5'
-
- Recovered Sample
No Bedrock
-
No Groundwater
25
i
30
35
40
45
50
Note:4 The stratification lines
represent the approximate
55
boundaries between the soil typpes;
the transitions may be gradual.
Sladden Engineering
APPENDIX B
LABORATORY TESTING
Representative bulk and relatively undisturbed soil samples were obtained in the field and returned
to our laboratory for additional observations and testing. Laboratory testing was generally
performed in two phases. The first phase consisted of testing in order to.determine the compaction of
the existing natural soil and the general engineering classifications of the soils underlying the site.
This testing was performed in order to estimate the engineering characteristics of the soil and to
serve as -a basis for selecting samples for the second phase of testing. The second phase consisted of
soil mechanics testing. This testing including consolidation, shear strength and expansion testing
was performed in order to provide a means of.developing specific design recommendations based on
the mechanical properties of the soil.
CLASSIFICATION AND COMPACTION TESTING
Unit Weight and Moisture Content Determinations: Each undisturbed sample was weighed and
measured in order to determine its unit weight. A small portion of each sample was then subjected
to testing in order to determine its moisture content. This was used in order to determine the dry
density of the soil in its natural condition. The results of this testing are shown on the Boring Logs.
Maximum Density -Optimum Moisture Determinations: Representative soil types were selected for
maximum density determinations. This- testing was performed in accordance with the ASTM
Standard D1557-91, Test Method A. The results of this testing are presented graphically in this
appendix. The maximum densities are compared to the field densities of the soil in order to
determine the existing relative compaction to the soil. This is shown on the Boring Logs, and is.
useful in estimating the strength and compressibility of the soil.
ClassificationTesting: Soil samples were selected for classification testing. This testing consists of
mechanical grain size analyses and Atterberg Limits determinations. These provide information for
developing classifications for the soil in accordance with the Unified Classification System. This
classification system categorizes the soil into groups having similar engineering characteristics. The
results of this testing are very. useful in detecting variations in the soils and in selecting samples for
further testing.
SOIL MECHANIC'S TESTING
Direct Shear Testing: One bulk sample:* was selected for Direct Shear Testing. This testing
measures the shear strength of the soil under various normal pressures and is used in developing
parameters for foundation design and lateral design. Testing was performed using recompacted test
specimens, which were saturated prior to testing.' Testing was performed using a strain controlled
test apparatus with normal pressures ranging from 800 to 2300 pounds per square foot.
Expansion Testing: One bulk sample was selected for Expansion testing. Expansion testing was
performed in accordance with the UBC Standard 1812. This testing consists of remolding, 4-inch
diameter by 1-inch thick test specimens to a moisture content and dry density corresponding to
approximately 50 percent saturation. The. samples are subjected to a surcharge of 144 pounds per
square foot and allowed to reach equilibrium. At that point the specimens are inundated with
distilled water. The linear expansion is then measured until complete.
Sladden Engineering
Proposed Big House Apa-rtcnents / Parcel 3 of Tract 27131
' NEC Washington Street & Darby Road / La Quinta, California ,
Date: 9-23-03 BorinLy
No.
9 Job No.: 544-3432
P.
DESCRIPTION
°a�'
q
o
REMARKS
42
Cj
°
Sand: Brown,
SP/S
-
slightly silty, fine grained
5
6/8/14
"
101
0.5
14% passing #200
10
9/14/17
"
98
0:5
---
7% passing #200
-
Total Depth = 11.5'
-
- Recovered Sample
No Bedrock
-
No Groundwater
1s
;
20
,
25
s
30
35
,
40
;
45
,50
Note: The stratification lines '
represent the approximate
55
boundaries between the soil types;
the transitions may be gradual.
r
Maximum Density/Optimum Moisture
ASTM D698/D1557
Project Number:
544-3432 .
Project Name:
Darby Rd.
Lab ID Number:
Sample Location:
Bulk l @ 0-5'
Description:
Sand
Maximum -Density:
111 pcf
Optimum Moisture
10.5%
Sieve Size % Retained .
145
140
135
130
w
u
a'
125
a
as
A
120
L
A
115
110
105
100
3/4
3/8"
#4
0 5 10 15
Moisture Content, %
October 24, 2003
ASTM D-1557 A
Rammer Type: Machine
20 25
Max Density Sladden Engineering
Revised 12/03/02
1.8
1.6
1.4
O
O
1.2
1.0
ram.
.8
H
6
.4
.2
DIRECT SHEAR.TEST
i
2
.4 ..6 .8 1.0 1.2 1.4 1.6 1.8
NORMAL LOAD (KIPS / FOOI2 )
0=320
c = '120 psf
Where 0 = Shear Angle
c = Cohesion
Gradation
ASTM C117 & C136 i
Project Number: 544-3432 October 24, 2003
Project Name: Darby Rd.
Sample ID: Bulk 1 @ 0-5'
-. Sieve
Sieve
Percent
Size, in
Size, mm
Passing
1 "
25.4
100
3/4"
19:1
100
1/2"
12.7
100
3/8"
9.53
.100
#4
4.75
100
#8
2:36
100 ,
#16
1.18
100
#30
0.60
94
450
0.30
63
#100
0.15
36
#200
0.074
11
" 11111�■I��n11111■�I�Iliill�■■■IIIII�■■■IIIII�■■■
IIIII�■■■11111�■■■Illi►i�■■■IIIII�■■■11111�■■■
�' 11111�■■■IIIII�■■■11111\■■■IIIII�■■■IIIII�■■■
IIIII�■■■11111�■■■IIIII►1■■■11111�■■■11111�■■■
'' IIIII�■■■11111�■■■11111\\■■IIIII�■■■IIIII�■■■
, IIIIIi■■■11111�■■■11111�1\■®IIIII�■■■IIIII�■■■
11111�■■■11111�■■■IIIII�\1■■IIIIIS■■■IIIII�■■■
IIIII�■■■IIIII�■■■IIIII�Li■11111�■■■11111�■■■
. '' IIIII�■■■IIIII�■■■IIIII�■1\■11111!■■■11111�■■■
IIIII�■■■11111�■■■IIIII�■\\■IIIII�■■■11111�■■■
' 11111�■■■11111�■■■11111�■■■IIIII�■■■IIIIIO■■■
'- , , 11111�■■■IIIII�■■®IIIII�■■1�111115■■■IIIII�■■■
11111�■■■11111�■■■11111�■■l�IIIII�■■■IIIIIi■■■
IIIII�■■■11111�■■■IIIII�■■�\IIIII�■■®IIIII�■■■
IIIII�■■■IIIII�■■■IIIII�■■�\IIIII�■■■IIIII�■■■
11111�■■■IIIII�■■■IIIII!■■�11111�■■®11111�■■■
' IIIII�■■■11111�■■■IIIII�■■■11111�■■■IIIIIO■■■
11111�■■■IIIII�■■■11111�■■■II!!1�■■■11111,■■■
IIIII�■■®IIIII�■■■11111�■■■11111�■■■IIIIIe■■■
IIIII�■■■IIIII�■■■11111�■■■11111�■■■IIIIIS■■®
oil
Gradation Sladden Engineering
Revised 11/20/02
Gradation
ASTM C1 17 & C136
Project Number:
544-3432
October 24, 2003
Project Name:
Darby Rd.
Sample ID:
Boring 3 @ 20'
Sieve
Sieve
Percent
Size, in
Size, mm
Passing '
1"
25A
100
3/4"
19.1
100
1 /2"
12.7
100
3/8"
9.53
100 ,
#4
4.75
100
#8
2.36
100
#16
1.18
160
#30
0.60
96
#50
0.30
76
#100
0.15
36 ,
#200
U74
8
" I1111■■1■�r111111■■I�Illi'!■■■■IIIII■■■■IIIII■■■■
• IIIII■■■■IIIII■■■■IIIII\■■■IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII►\■■IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■1\■■IIIII■■■■IIIII■■■■
'' IIIII■■■■IIIII■■■■IIIII■!`�■IIIII■■■■IIIII■■■■
, IIIII■■■■IIIII■■■■IIIII■■1�■IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■■\\■IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■■\1■IIIII■■■■IIIII■■■■
. • � IIIII■■■■IIIII■■■■IIIII■■�1■IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■■��IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■■■1�11111■■■■IIIII■■■■
�- , , IIIII■■■■IIIII■■■■IIIII■■■1�11111■■■■IIIII■■■®
IIIII■■■■IIIII■■■■IIIII■■■l�IIIII■■■■IIIII■■■■
, IIIII■■■■IIIII■■■■IIIII■■■��IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■■■®\IIIII■■■■IIIII■■■■
, IIIII■■■■IIIII■■■■IIIII■■■�111111■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■■■■�1111■■■■IIIII■■■■
, IIIII■■■■IIIII■■■■IIIII■■■■1►111■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■■■■II�i1■■■■IIIII■■■■
, IIIII■■■■IIIII■■■■IIIII■■■■IIIII■■■■IIIII■■■■
Gradation
Sladden Engineering
Revised 11/20/02
Gradation
'
ASTM C117 & C136
Project Number:
544-3432
Project Name: '
Darby Rd.
Sample ID:
goring 5 @ 10"
Sieve
Sieve .
Percent
Size, in
Size, mm
Passing
1"
25.4
100
3/4"
19.1
100
.1/2"
12.7
100
3/8"
9.53
100
-#4
4.75
100
#8
2.36
100
#16
1.18
100
#30
0.60
98
#50
0.30
68
#100
0.15
33
#200
0.074
10
" IIIIII■I mill111■mm111c-]1■■■111111■■■1111
IIIIl1■■■\\IIII■■■IIII\\■■■IIIIl1■■■IIII
' Illlll■■■111111■■■11111►1■■■IIIIII■■■IIII
111111■■■Illlll■■■IIIll \\■■IIIIII■■■IIII
IIII11■■■111111■■■1111111\■■111111■■■IIII
IIII11■■®IIIIII■■■\\IIII\1■■IIIIII■■■IIII
111111■■■111111■■■IIII Ilai■II Illl■■■IIII
111111■■■111111■■■111111■1\■Illlll■■■IIII
. •'IIII11■■■111111MINIMUM ■\\■111111■■■IIII
IIIIII■■■IIIIII■■■IIIIII■\1■\\IIII■■■IIII
' \\IIII■■■\\IIII■■■11111111 Milli EMIR
\\IIII■■■\\IIII■■■11111e■■►®Nil 1l■■■IlI
111111■■■11111111 Hills 111111■■■111
IIIIII■■■HIM ■■■111111■■L77Mllllll■■■Ill
111111■■■llllll■■■III1l1■■NL\111111■■■111
ill 1INN ■■111111■■=Illlll■■M1llllll■■■Ill
' 111111■■■111111■■■ill 111■■■`►11111■■■111
111111■■®III111■■■IllIll ■■■IIVIII■■■111
llilmmili llll mmiiiill ■■m■iiiili■■■miii
00.0 10.0
1.0 0.1
Sieve Size, mm
October 24, 2003
0.0 0.0
Gradation Sladden Engineering
Revised 11/20/02
Gradation
ASTM C117 & C136
Project Number:
544-3432
October 24, 2003
Project Name:
Darby Rd.
Sample ID:
Boring 7 @ 10'
3
Sieve
Sieve
Percent
Size, in
Size, mm
Passing
1"
25.4
100
3/4"
19.1
100
1/2"
12.7
100
3/8"
9.53
100.
#4
4.75
100
#8
2.36
100
1
#16
1.18
100
#30
0.60
92
#50
0.30
51
#100
0.15
31 '
'
#200
0.074
t
11
" IIIII■■■Ir�111111■lI�IiC�11■■■■IIIII■■■■IIIII■■■■
. , IIIII■■■■IIIII■■■■III��■■■■IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■111111■■■■IIIII■■■■IIIII■■■■
, IIIII■■■■IIIII■■■■IIIII\■■■IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII►1■■■IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■1111111■■■IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII\■■IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■►'■®IIIII■■■■IIIII■■■■
. •' IIIII■■■■IIIII■■■■IIIII■11■■IIIII■■■■IIIII■■■®
IIIII■■■■IIIII■■■■IIIII■!'!■IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■■1\■IIIII■■■■IIIII■■■■
'- , , IIIII■■■■IIIII■■■■IIIII■■��■IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■■■IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■■■!`IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■■■�\IIIII■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■■■��IIIII■■■■IIIII■■■■
' IIIII■■■■IIIII■■■■IIIII■■■■►1111■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■■■■II�l1■■■■IIIII■■■■
IIIII■■■■IIIII■■■®IIIII■■■■11�11■■■■IIIII■■■■
IIIII■■■■IIIII■■■■IIIII■■■■IIIII■■■■IIIII■■■■
off of of
Gradation Sladden Engineering
Revised 11/20/62
F
Expansion Index
ASTM D 4829/UBC 29-2
Job Number: 544-3432 Date: 10/24/03
Job Name: Darby Rd. Tech: Jake
Lab ID:
Sample ID: Bulk 1 @ 0-5'
Soil Description: Sand
Wt of Soil + Ring:
585.0
Weight of Ring:
179.0,
Wt of Wet Soil:
406.0
Percent Moisture:
9%
Wet Density, pcf:
123.0
Dry Denstiy, pcf:
112.9
Saturation:
49.3
Expansion
Rack #
Date/Time
10/27/03
7:00 a.m.
Initial Reading
0.500
Final Reading
0.500 .
Expansion Index 0
(Final -Initial) x 1000
EI
Sladden Engineering
Revised 12/10/02
ANAHEIM TEST LABORATORY
3008 S. ORANGE AVENUE
SANTA ANA, CALIFORMA 92707
PHONE (714.) 549-7267
O: SLADDEN ENGINEERING:
6782 STANTON AVE. SUITE A DATE: 10/02/03
BUENA PARK, CA. 90621
RO. No. Chain of Custody
Sh!pper No,
ATTN : ' BRETT / DAVE lab. No. A- 3 8 8 5
Specification:
Material: SOIL
PROJECT: #544-3432
BULK 1 @ 0-5'
ANALYTICAL REPORT
CORROSION SERIES
SUMMARY OF DATA
pH SOLUBLE SULFATES SOLUBLE CHLORIDES '.MIN. RESISTIVITY
per CA. 417 per CA. 422 per CA. 643
ppm ppm ohm -cm
6.9 74 1,126 600 max
FORM N2
a
c . '
t
Sladden Engineering
October 28, 2003 -12- Project No. 544-3432
03-10-695
1997 UNIFORM BUILDING CODE SEISMIC DESIGN INFORMATION
The International Conference of Building Officials 1997 Uniform Building Code contains substantial
revisions and additions to the earthquake engineering section in Chapter 16. Concepts contained in
the code that will be relevant to construction of the proposed structures are summarized below.
Ground shaking is expected to be the primary *hazard most likely to affect the site, based upon
proximity to significant faults capable of generating large earthquakes. Major fault zones considered
to be most likely to create strong ground shaking at the site are listed below.
Fault Zone
Approximate Distance
From Site
Fault Type
(1997 UBC)
San Andreas
7.9 km
A.
San Jacinto
35.7 km
A ,
Based on our field'observations and understanding of local geologic conditions, the soil profile type
judged applicable to this site is SD, generally described as stiff or dense soil. The site is located
within UBC Seismic Zone 4. The following table presents additional coefficients and factors relevant
to seismic mitigation for new construction upon adoption of the 1997 code.
Near -Source
Near -Source
Seismic
Seismic
Seismic
Acceleration
Velocity
Coefficient
Coefficient.
Source
Factor, N.
Factor, No
Ca
C...
San Andreas
1.1
1.4
0:44Na
0.64Nv
San Jacinto
1.0
1.0
0.44Na '
0.64Nv
Sladden Engineering
***********************
* *
* E Q F A U L T
* *
* Version 3.00
* *
DETERMINISTIC ESTIMATION OF
PEAK ACCELERATION FROM DIGITIZED FAULTS
JOB NUMBER: 544-3432
DATE: 10-20-2003
JOB NAME: Darby Road & Washington Street
La Quinta, California
CALCULATION NAME: Test Run Analysis
FAULT -DATA -FILE NAME:' CDMGFLTE.DAT
SITE COORDINATES:.
SITE LATITUDE: 33.7333
SITE LONGITUDE: 116.3008
SEARCH RADIUS: 100 mi
ATTENUATION RELATION: 5) Boore et al. (1997) Horiz. - SOIL (310)
UNCERTAINTY (M=Median, S=Sigma): M Number of Sigmas: 0:0
DISTANCE MEASURE: cd_2drp
SCOND: 0
Basement Depth: 5.00 km .Campbell SSR: Campbell SHR:
COMPUTE PEAK HORIZONTAL ACCELERATION
FAULT -DATA FILE USED: CDMGFLTE.DAT
MINIMUM DEPTH VALUE (km): 0.0
EQFAULT SUMMARY
-----------------------------
DETERMINISTIC SITE PARAMETERS
-----------------------------
Page
------=------------------------------------------------------------------------
(ESTIMATED MAX. EARTHQUAKE EVENT
1
APPROXIMATE I --------------------------------
ABBREVIATED I
DISTANCE I.MAXIMUM
I
PEAK
JEST. SITE
FAULT NAME I
mi
(km) (EARTHQUAKE(
SITE
JINTENSITY
1
_
I
MAG.(Mw) I
ACCEL. g
IMOD.MERC.
---------- --------- ____________1=====____=====1==========I==========1=====____
SAN ANDREAS - Coachella 1
4.9(
7.9)1
7.1 1
0.391
1 X
SAN ANDREAS - Southern, I
4.9(
7.9)1
7.4 1
0,.458
1 X
BURNT MTN. 1
15.3(
24.,6)1
6,4 1
0.128:
1 VIII
EUREKA PEAK I
16.3(
26.2)1
6.4 1
0.122
1 .VII
SAN ANDREAS - San Bernardino 1
16.6(
26.7)1
7.3 1
0.194
1 VIII
SAN JACINTO-ANZA 1
22.2(
35.7)1
7.2 1
0.148
1 VIII
SAN JACINTO-COYOTE CREEK 1
22.5(
36.2)1
6,.8 1
0.118
1 VII
PINTO MOUNTAIN 1
28.0(
45.0)1
7.0 1
0.111
1 VII
EMERSON So. - COPPER MTN. 1
30.1(
48.4)1
6.9 1
0.100
1 VII
LANDERS I
30.4(
49.0)1
.7.3 1
0.122
1 VII
PISGAH-BULLION MTN.-MESQUITE LK 1
32.7(
52.6)1
7.1 1
0.104
1 VII
NORTH FRONTAL FAULT 'ZONE (East) 1
35.2(
56.7)1
6.•7 1
0.097
1 VII
SAN JACINTO-SAN JACINTO VALLEY 1
35.4(
57.0)1
6.9 1
0.088
1 VII
SAN JACINTO - BORREGO 1
37.3(
60.1)1
6.6 1
0.072
1 VI
JOHNSON VALLEY (Northern) 1
41.3(
66.4)1
6.7 1
0.070
1 VI
EARTHQUAKE VALLEY 1
41.4(
66.6)1
6.5 1
0.063
1 VI
CALICO - HIDALGO 1
43.2,(
69.5)1
7.1 1
0.084
1 VII
BRAWLEY SEISMIC ZONE 1
43.3(
69.7)1
6.4 1
0.058
1 VI,
ELSINORE-JULIAN 1
44.4(
71.4)1
7.1 1
0.082
1 VII
LENWOOD-LOCKHART-OLD WOMAN SPRGSI
4.7.0(
75.6)1
7.3 1
0.087
1 VII
NORTH FRONTAL FAULT ZONE (West) 1
47.3(
76.2)1
7.0 1
0.090
1 VII
ELSINORE-TEMECULA I
47.8(
76:9)I
6.8 1
0.066
1 VI
ELMORE RANCH I
50.8(
81.7)1
6.6 1
0.057
1 VI
ELSINORE-COYOTE MOUNTAIN 1
53.2(
85.6)1
6.8 1
0.061
1 VI
HELENDALE - S. LOCKHARDT 1
54.9(
88.3)1
7.1 1
.0.070
.1 VI
SUPERSTITION MTN. (San Jacinto) 1
55.6(
89.5)1
6.6 1
0.053
1 VI
SUPERSTITION HILLS (San Jacinto)(
56.4(
90.8)1
6.6 1
0.052
1 VI
SAN JACINTO-SAN BERNARDINO 1
57.2(
92.1)1
6.7 1
0.055
1 VI
ELSINORE-GLEN IVY 1.
60.5(
97.4)1
6.8 1
0..055
1 VI
CLEGHORN J
64.3(
103.5)1
6.5 1
0.045
1 VI
IMPERIAL 1
70.6(
113.6)1
7.0 1
0.054
I VI
CUCAMONGA' 1
72.2(
116.2)1
7.0 1
0.065
1 VI
CHINO -CENTRAL AVE. (Elsinore) 1
73.1(
117.7)1
6.7 1
0.055
1 VI
LAGUNA SALADA 1
73.7(
118.6)1
7.0 1
0.053
1 VI
NEWPORT-INGLEWOOD (Offshore) 1
76.1(
122.5)1
6.9 I
.0.049
1 VI
ROSE CANYON. 1
76.3:(
122.8)1
6.9 1
0.049
1 VI
WHITTIER 1
77.2(
124.3)1
6.8 1"
0.046
1 VI
SAN ANDREAS - Mojave 1
81.1(
130.5)1
7•.1 1
0.052 .1
VI
SAN ANDREAS - 1857 Rupture 1
81.1(
130.5)1
7.8 1
0.075
1 VII
SAN JOSE 1
84.1(
135.•3)1
6.5, 1
0.044
1 VI
-----------------------------
DETERMINISTIC
-----------------------------
SITE PARAMETERS
Page 2 '
-------------------------------------------------------------------------------
I
(ESTIMATED MAX.
EARTHQUAKE EVENT
APPROXIMATE 1----------------------------=--.
ABBREVIATED
I •DISTANCE
I MAXIMUM I
PEAK
JEST. SITE
FAULT NAME
I , mi
(km) , JEARTHQUAKEI
SITE
JINTENSITY
I
I.MAG.(Mw) I ACCEL.
g
IMOD.MERC'.
GRAVEL HILLS - HARPER LAKE
1 86.3(
138.9)1 6.9 1
0.044
1 VI
SIERRA MADRE
1 86.9(
139.9)1 7:0. I
0.056
1' VI
ELYSIAN PARK THRUST
1 89.4(
143.8)1 - 6.7 1
0.047
1 VI
CORONADO BANK
1 91.7(
147.5)1 7.4 1
0.055
1 VI
NEWPORT-INGLEWOOD (L.A:Basin)
1 93.7(
150.8)1 6.9 1
0.041
1 V
CLAMSHELL-SAWPIT
1 95.4(
153.6)1 6.5 1
0.040
1 V
COMPTON THRUST
1 96.3(
154.9)1 6.8 1
0..047
1 VI
BLACKWATER
1 98.2(
158.1)1 6.9 1
0.040
1 V
PALOS VERDES
1 99.2(.159.6)I
7.1 I
0.044"
1 VI
-END OF SEARCH- 49 FAULTS FOUND WITHIN
THE SPECIFIED SEARCH
RADIUS.
THE SAN ANDREAS - Coachella
FAULT
IS CLOSEST TO THE
SITE.
IT IS ABOUT 4.9 MILES (7.9 km)
AWAY.
LARGEST MAXIMUM -EARTHQUAKE SITE
ACCELERATION: 0.4575 g
CALIFORNIA FAULT MAP
Darby Road & Washington Street / La Quinta
1100
1000
900
800
700
600
500
400
300
200
100 SITE
0 Q
-100
-400 -300 -200 -100 0 100 200 300 400' 500 600
STRIKE -SLIP FAULTS
5) Boore et al. (1997) Horiz. -SOIL (310)
M=5 M=6 M=7 M=8
1
n
c�
nL1
W
rl
�U
� .01
.001
1
2
10 100
Distance [adist] (km)
DIP -SLIP FAULTS
5) Boore et al. (1997) Horiz: - SOIL (310)
s �
M=5 M=6 - M=7, M=8
.001
1
10 100
Distance [adist] (km)
MAXIMUM EARTHQUAKES
Darby Road &. Washington' Street / La Quinta
1
-.
C
c
.1
o
c�
L
U
U
Q
.01
1 10 100
Distance (mi)
EARTHQUAKE MAGNITUDES & DISTANCES
Darby Road & Washington Street / La Quinta
7.75
7.50
7.25
a�
c 7.00
c�
6.75
6.50
A. 1 10 100
Distance (mi)
l'
13ORMSTRUCTURAL ENGINEERS
• u
CITY OF lei QLJ
September 18, 2006 { BUILDING &-SAFETY DEPT.
PROVED
M
CONSTRUCTION
Ms. Yvette Hightower
Humphreys & Partners Architects, L.P. DATE BY
5350 Alpha Road
Dallas, TX 75240
Re: Medittera Apartment Homes (Garages, Kiosk, Cabana)
Subj: Structural Truss Shop Drawing Review
Dear Ms: Hightower,
Accompanying this letter, we are returning (2) sets of AC Houston Truss shop drawings -
bearing the same imprint as at the base of this letter. The drawings were reviewed for
general conformance with design concept of the project as indicated by the structural.
documents prepared by our office. We have not reviewed quantities or dimensions. We have
not reviewed fabrication processes, techniques of construction, or coordination of the work
with that of any other trade. We have not reviewed the manner in which the work would be
performed or if it may be performed in a safe and satisfactory manner. Should we have made
any comments or corrections on the drawings, these comments or. corrections do not relieve
the contractor from compliance with the structural documents. In as much as we have
s
reviewed the drawings only for general conformance with -the design concept, unless
Costa Mesa, CA
deviations from the design intent have been clearly indicated as such, we may not have made
note of them and the contractor is not relieved from compliance with the structural documents.
Modesto, CA
Our review of these drawings is not an indication of their preparation under our supervision.
These shop drawings are being returned with no objection to their use.
Pleasanton, CA
If you have any questions, please contact`our office.
Roseville, CA
Very truly yours, BORM '
BORM ASSOCIATES, INC.
Las Vegas, I v
SEP 18 2006
Brandon Winter
Phoenix,
Project Engineer
'Structural Shop Drawings Y
BW:I/ 5545 091806 Truss Review Gar, Mail, Cab Reter.toletter bearing this imprint.tor intormallon
Tucson, Az
Distribution:
(2) Addressee via overnight ���������.
Denver, CO
(1) File 5545
(1) AC Houston via fax (760) 347-8515
Q
Enclosure: (2) Truss Shop Drawings by AC Houston Truss 5545 - 0 8
Be'i'"9; PR
dated "09/17/06".
` ACCEPTABLE FOR CONSTRUCTION
GEOTECHNICAL INVESTIGATION
PROPOSED BIG HOUSE APARTMENT COMPLEX
PARCEL 3 OF TRACT 27131
NEC WASHINGTON STREET & DARBY ROAD
LA QUINTA, CALIFORNIA
CITY OF LAQUINTA
f Y - BUILDING &SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
8 06 BY
#'' l061A144f �2
-Prepared By-
Sladden Engineering
39-725 Garand Lane, Suite G
Palm Desert, California 92211•
(760) 772-3893
Sladden<Engineering "
Sladden En - ineerin -
g g
6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369
39-725 Garand Ln., Suite G, Palm Desert, CA 92211 (760) 772-3893 Fax (760) 772-3895
October 28, 2003 . " Project No. 544-3432
03-10-695
White Company Residential
c/o Saxon Engineering Services
1030 Calle Sombra, Suite A2
San Clemente,, California 92673
Attention: Mr. Kurt Saxon
Project: Proposed'Big House Apartments.
NEC Washington Street and Darby Road
La Quinta, California
Subject: Geotechnical Investigation
Presented herewith is the report of our Geotechnical .Investigation conducted 'at the site of the
proposed Big House Apartment Complex to be located on the northeast corner of Washington Street
and Darby Road in the City of La Quinta, California. The investigation was performed in order to
provide recommendations for site preparation and to assist in foundation design for -the proposed
residential structures.
This report presents the results of our' field investigation and laboratory testing 'along with
conclusions and recommendations for foundation design and site preparation. This report completes
our original scope of services as understood in our proposal dated September 11, 2003.
We appreciate the opportunity to provide service to you on this project. -If you have any questions
regarding this report, please contact the undersigned
Respectfully submitted,
SLADDEN ENGI RINGQ�oFESS/OOV
co
Brett L. And son �Xp. 9130106 X- ;
Principal Engineer o�
SER/ c S'T CIV1V`� .
p OF CAS\k®�
Copies: . 6/Saxon Engineering Services
Sladden Engineering
a
GEOTECHNICAL INVESTIGATION
PROPOSED BIG HOUSE APARTMENT COMPLEX
. PARCEL 3 OF TRACT 27131
NEC WASHINGTON STREET & DARBY ROAD
i LA QUINTA, CALIFORNIA
October 28, 2003
F
! TABLE OF CONTENTS
i
INTRODUCTION...........................:...................................................
SCOPEOF WORK..::....:....................................................................
PROJECT DESCRIPTION..................................:.............................
SUBSURFACE CONDITIONS.........................................................
CONCLUSIONS AND RECOMMENDATIONS ........... I ...................
FoundationDesign......................................................................
Settlements..................................................................................
Lateral Design ...............................
.............................................................
RetainingWalls ...................................... :................ ...................................
ExpansinSoils.........................:.................................................................
Concrete Slabs-on-Grade............................................................................
SolubleSulfates.....................:.................................:..................................
Shrinkage and Subsidence.........................................................................
GeneraPSite Grading...................................................................
1. Clearing and Grubbing ...........................:.........................
2. Preparation of Building Areas .........................................
3. Preparation of Surfaces to Receive Compacted Fill.....:..
4. Placement of Compacted Fill...........:..................I.............
5. Preparation of Slab and Pavement Areas .......................
6. Testing and Inspection ..........................
..................................... 1
..................................... 1
..................................... 1
..................................... 2
..................................... 2
..................................... 3
.:................................... 3
........................ 3
........................ 4
........................ 4
........................ 4
........................ 4
........................ 4
................ 5
5
.
..................................... 5
..................................... 5
..................................... 5
..................................... 6
......................................... 6
GENERAL!
I ........................................................................................................ .
APPENDIX A - Site Plan and Boring Logs
j Field Exploration
APPENDIX B - Laboratory Testing
Laboratory Test Results
APPENDIX C - 1997 UBC Seismic Design Criteria
.................... 6
Sladden Engineering
October 28, 2003
-1-
INTRODUCTION
Project No. 544-3432
03-10-695
This report presents the results of our Geotechnical Investigation performed in order to provide
recommendations for the design and construction of the foundations for the proposed apartment
complex. The project site is located. on the northeast corner of Washington Street and Darby Road in
the City of La Quinta, California. The preliminary plans indicate that the proposed development
will consist of 18 apartment buildings and various related site improvements. The associated site
improvements will include paved roadways, concrete driveways, concrete walkways, various
underground utilities, and landscape areas.
SCOPE OF WORK
The purpose of our investigation was to determine certain engineering characteristics of the near
surface, soils on the site in order to develop recommendations for foundation design and site
preparation. Our investigation included field exploration, laboratory testing, engineering analysis
and the preparation of this report. Evaluation of environmental issues or hazardous wastes was not
within the scope of services provided. Our investigation was performed in accordance- with
contemporary geotechnical engineering principles and practice. We make no other warranty, either
express or implied.
PROJECT DESCRIPTION
The project site is located on the northeast corner of the future alignment of Palm Royale Drive and
Washington Street in the City of La Quinta, California. The preliminary plans indicate that the
project will include 18 multi -unit apartment buildings. It is our understanding that the proposed
apartment buildings will be of relatively lightweight wood -frame construction and will be supported
by conventional shallow spread footings and concrete slabs on. grade. The associated improvements
will include concrete walkways and driveways, landscape areas and various underground utilities.
The project site is presently vacant and the ground surface is covered with scattered desert brush,
short grass, weeds and minor debris. The site is relatively level throughout but distinct agricultural
levels provide topographical relief of up to 13 feet between the western and eastern portions of.the
site. The majority of the properties surrounding the site are presently vacant. There are
underground and overhead utilities along the existing streets and may transect the site.
Based upon our understanding of the proposed construction and our previous experience with
lightweight wood -frame structures, we expect that isolated column loads will be less than 30 kips
and wall loading will be less than 2.0 kips per linear foot. Grading is expected to include substantial
cuts and. fills to match the. nearby elevations and to. construct .level building pads. This does not
include removal and/or recompaction of the loose surface soils the primary foundation bearing soils
within the building areas. If the anticipated foundation loading or site grading varies substantially
from that assumed the recommendations included in this report should be reevaluated.
Sladden Engineering
't.
October 28, 2003 -2- Project No. 544-3432
03-10-695
SUBSURFACE CONDITIONS
The site soils were determined to consist primarily of native fine-grained windblown sands. The
native windblown sands were fairly uniform in composition throughout the site and the depth of our
borings. The windblown sands were typically slightly silty and contained less than 15 percent fines
(clay and silt sized particles).
In general, the site soils appear somewhat loose near the surface but sampler penetration resistance
(as measured by field blow counts) indicates that density within the native soils underlying the site
generally increases with depth. The site soils were found to be dry throughout the depth of our
exploratory borings.
Laboratory classification testing indicates that the near surface soils consist primarily of fine-
grained windblown sands. Expansion testing indicates that the surface soils are non -expansive and
fall within the "very low" expansion category in accordance with the Uniform Building Code
classification system. The loose and dry conditions suggest that the near surface soils may be
susceptible to detrimental settlements due to the anticipated foundation loading and the
introduction of water.,
Groundwater was not encountered within our borings but is expected to be in excess of 100 feet
below the existing ground surface in the vicinity of the site. Groundwater should not be a factor in
foundation design or construction.
CONCLUSIONS AND RECOMMENDATIONS
Based upon our field and laboratory investigation, it is our, opinion that the proposed apartment
complex is feasible from a soil mechanic's perspective provided that the recommendations included in
this report are considered in building foundation design and site preparation. Due to the somewhat
loose and potentially compressible condition of some of the near surface soils, remedial grading
including overexcavation and/or watering and recompaction is recommended for the proposed
building. areas. We recommend that remedial grading within the proposed building areas include
overexcavation and/or extensive site watering and recompaction of the primary foundation bearing.
soils in order to provide a uniform mat of compacted soils beneath the building foundations. Specific
recommendations for site preparation are presented.in the Site Grading section of this report.
Groundwater was not encountered within our borings and groundwater is expected to be in excess of
100 feet below the existing ground surface in the vicinity of the site. Due to the depth to.
groundwater, specific liquefaction analyses were not performed. Based upon the depth to
groundwater, the potential for liquefaction and the related surficial affects of liquefaction impacting
the site are considered negligible.
The site is located within an active seismic area of Southern California within approximately 7.9
kilometers of the San Andreas fault system. Strong ground motion resulting from earthquake
activity along the nearby San Andreas or San Jacinto fault systems is likely to impact the site during
the anticipated lifetime of the structures. Structures should be designed by professionals familiar
with the site's geologic and seismic setting. As a minimum, structure design should conform with
Uniform Building Code (UBC) requirements for Seismic Zone 4. Pertinent seismic design
parameters as included within the 1997 UBC are summarized in Appendix C.
Sladden Engineering
October 28, 2003 -3- Project No. 544-3432
03-10-695
Caving did occur within each of our exploratory borings and the surface soils will be susceptible to
caving within deeper excavations. All excavations should be constructed in accordance with the
normal CalOSHA excavation criteria. On the basis of our observations of.the materials encountered,
we anticipate that the subsoils will conform to those described by CalOSHA as Type C. Soil
conditions should be verified during construction by a "Competent person" employed by the
Contractor.
The surface soils encountered during our investigation were found to be non -expansive. Laboratory
testing indicated an Expansion Index of 0 that corresponds with the "very low" expansion category in
accordance with UBC Standard 18-2. If imported soils are to be used during grading, they should
have an Expansion Index of less than 20.
The following recommendations present more detailed design criteria that have been developed: on
the basis of our field and laboratory investigation.
Foundation Design: . The results of our investigation indicate that either conventional
shallow continuous footings or isolated padfootings that are supported upon properly
recompacted soils may be expected to provide satisfactory support for the proposed
structures. Recompaction should be performed as described in the Site Grading Section of
this report.
Footings should extend at least 12 inches beneath lowest adjacent grade. Isolated square or
rectangular footings at least 2 feet.square,may be designed using an allowable bearing value
of 1800 pounds per square foot. Continuous footings at'least 12 inches wide may be designed
using an allowable bearing value of 1500 pounds per square foot. Allowable increases of 200
psf for each additional 1 foot of width and 250 psf for each additional 6 inches of depth may
be utilized if desired. The maximum allowable bearing pressure should be 2500 psf:. The
allowable bearing pressures are for dead and frequently applied live loads and may be
increased by 1/3 to resist wind, seismic or other transient loading.
The 'recommendations made in the preceding paragraphs are based on the assumption that
all footings will be supported by properly compacted soil. All grading shall be performed
under the testing and inspection of the Soils Engineer or his representative. Prior to the
placement of concrete, we recommend that the footing excavations be inspected in order to
verify that they extend into compacted soil and are free of.loose and disturbed materials.
Settlements: Settlements may result from the anticipated foundation loads. These
estimated ultimate settlements are calculated to be a maximum of 1 inch when,using the
recommended bearing values. As a practical matter, differential settlements between
footings can be assumed as one-half of the total settlement:
Lateral Design: Resistance to lateral loads can be provided by a combination of friction
acting at the base of the slabs or foundations and passive earth pressure along the sides of
the foundations. A coefficient of friction of 0.45 between soil and concrete may be used with
dead load forces only. A passive earth pressure of 300 pounds per square foot, .per foot of
depth, may be used for the sides of footings that are placed against properly compacted
native soils.
Passive earth pressure should be ignored within the upper 1 foot except where confined (such
as beneath a floor slab). When used in combination, either the passive resistance or the
coefficient of friction should be reduced by one-third.
Sladden Engineering
October 25, 2003 -4- Project No, 544-3432
03-10-695
Retaining Walls: Retaining walls may be required to accomplish the proposed construction.
Cantilever retaining walls may be designed using "active". pressures. Active pressures may
be estimated using an equivalent fluid weight of 35 pcf for native backfill soils with level
free -draining backfill conditions.
For walls that are restrained, "at rest' pressures should be utilized in design. At rest
pressures may be estimated using an equivalent fluid weight of 55 pcf for native backfill soils
with level free draining backfill conditions.
Expansive Soils: Due to the prominence of non -expansive soils on the site, special expansive
soil design criteria should not be,necessary for the design of foundations and concrete slabs -
on -grade. Final foundation and slab design, criteria should be established by the Structural
Engineer.
Concrete Slabs -on -Grade All. surfaces to receive concrete slabs -on -grade. should be underlain
by recompacted soils as described in the Site Grading Section of this report. Where slabs are
: to receive moisture sensitive floor coverings or where dampness of the floor slab is not
desired, we recommend the use of an appropriate vapor barrier. Vapor barriers should be
protected by sand in order to reduce the possibility of puncture and to aid in obtaining
uniform concrete curing.
Reinforcement of slabs -on -grade in order to resist expansive soil pressures may not be
required however, reinforcement will have a.beneficial effect in containing cracking due to .
concrete shrinkage. Temperature and shrinkage related cracking should be anticipated in.
all concrete slabs -on -grade. Slab reinforcement and the spacing of control joints should be
determined by the Structural Engineer. c
Soluble Sulfates: The soluble sulfate. concentrations of the surface soils was determined to be
74 parts per million (ppm). This is within the usual allowable limits for the use of Type II
cement and the use of Type V cement or special sulfate resistant'concrete mixes should not
be necessary.
Shrinkage and Subsidence: Volumetric shrinkage of the material that is excavated and
replaced as controlled compacted fill should be anticipated. We estimate that this shrinkage.
could vary. from 15 to 20 percent. Subsidence of the surfaces that are scarified and
compacted should.,be between 0.1 and 0.2 tenths of a foot. Shrinkage and subsidence will
vary adepending upon the type of equipment used, the moisture content of the soil at the time
of grading and the actual degree of compaction attained.
These values for. shrinkage and subsidence are exclusive of losses that will. occur due to the
stripping of the organic material from the site, the removal of deleterious materials and the
removal of debris, trees and other subsurface obstructions.
Sladden Engineering
October 28, 2003 -5- Project No. 544-3432
03-10-695
General Site Grading: All grading should be performed in accordance with the grading
ordinance of the City of La Quinta, California'. The following recommendations have been
developed on the basis of our field and.laboratory testing
Clearing and Grubbing: Proper clearing of any existing vegetation, associated root
systems, foundations or slabs, and debris will be very important. All surfaces to
receive compacted fill should be cleared of roots', vegetation, debris, and other
unsuitable materials that should be removed from.the site. Soils that are disturbed
due to the removal of the surface vegetation and debris should be replaced as
controlled compacted fill under the direction of the Soils Engineer.
2. Preparation of Building Area: In' order to provide. firm and uniform bearing
conditions, we recommend thorough site watering and recompaction of the near
surface native soils throughout the building and foundation areas. The building
areas should be watered. so that near optimum moisture content is attained to a
depth of at least 3 feet below existing grade or 3 feet below the bottom of the footings,
whichever is deeper. The exposed surface should then be compacted with heavy
equipment so that a minimum of 90 percent relative compaction is attained to a
depth of at least 2 feet below existing grade or 2 feet below the bottom of the footings,
whichever is deeper. Fill material may then be placed as recommended in Item 4
below. If the recommended depth of compaction cannot be attained in this manner,
overexcavation may be necessary.
3. Preparation of Surfaces to Receive Compacted Fill: Other areas to receive compacted
fill should be brought to near optimum moisture content and compacted to a
minimum of 90 percent relative compaction.
4. Placement of Compacted Fill: Fill materials consisting of on -site soils or approved
imported granular soils, should be spread in thin lifts, and compacted at near
optimum moisture content to a minimum of 90 percent relative compaction.
Imported material shall have an Expansion Index not exceeding 20. The contractor
shall notify the Soils Engineer at least 48 hours in advance of importing soils in order
to provide sufficient time for the evaluation of proposed import materials.
The contractor shall be responsible for delivering material to the site that complies
with the project specifications: Approval by the Soils Engineer will be based upon
material delivered to the site and not the preliminary evaluation of import sources.
Our observations of the material encounteredduring our investigation indicate that
compaction will be most readily obtained by means of heavy rubber -wheeled
equipment and/or vibratory compactors. At the time of our investigation, the subsoils'
were found to be very dry. A more uniform and near optimum moisture, content
should be maintained during recompaction and fill placement.
Sladden Engineering
'7.
October 28, 2003 -6- Project No. 544-3432
03-10-695
5. Preparation of Slab and Paving Areas: All surfaces to receive asphalt concrete
paving or concrete slabs -on -grade should be underlain by a minimum compacted fill
thickness of 12 inches. This may be accomplished by a combination of scarification
and recompaction of the surface soils and placement of the fill material as controlled
compacted fill. Compaction of the slab and pavement areas should be to a minimum
of 90 .percent. relative compaction.
6. Testing and Inspection: During grading tests and observations should be performed
by the Soils Engineer or his representative in order to verify that'the grading is being
performed in accordance with the project specifications. Field density testing shall
be performed in accordance with. acceptable ASTM test methods. The minimum
acceptable degree of compaction should be 90 percent of the maximum dry density as
obtained by the ASTM D1557-91 test method.. Where testing indicates insufficient
density, additional compactive effort shall be applied until retesting indicates
satisfactory compaction.
GENERAL
The findings and recommendations presented in this report are based upon an interpolation of the
soil conditions between the exploratory boring locations and extrapolation of these conditions
throughout the proposed building area. Should conditions encountered during grading appear
different than those indicated in this report, .this office should be notified.
This report is considered to be applicable for use by White Company Residential for the specific site
and project described herein. The use of this report by other parties or for other projects is not
authorized. The recommendations of this report are contingent upon monitoring of the grading
operation by a representative of Sladden Engineering. All recommendations are considered to be
tentative pending our review of the grading operation and additional testing, if indicated. If others
are employed to perform any soil testing, this office should be notified prior to such testing in order
to coordinate any required site visits by our representative and to assure indemnification of Sladden
Engineering.
Our investigation was conducted prior to the completion of plans for the project. We recommend that
a pre -job conference be held on the site prior to the initiation of'site grading. The purpose of this
meeting will be to assure a complete understanding of the recommendations presented in this report
as they apply to the actual grading performed.
Sladden Engineering
'
r
s
APPENDIX'A
Site Plan
Boring Logs
k
Sladden Engineering
10
APPENDIX A
FIELD EXPLORATION
For our field investigation 9 exploratory borings were excavated on September 23, 2003, using a
.truck mounted Mobile B-61 drilling rig and hollow -stem augers. The approximate exploratory boring
locations are indicated on the site plan included in this appendix. Boring logs are included in: this
appendix.
Representative undisturbed samples were obtained within our borings by driving a thin -walled steel
penetration sampler (California split spoon sampler) or a Standard Penetration Test (SPT) sampler
with a 140 pound hammer dropping approximately.30 inches (ASTM D1586). The number of blows
required to drive the samplers 18 inches was recorded in 6-inch increments and blowcounts are
indicated on the boring logs.
The California samplers are 3.0 inches- in diameter, carrying brass sample rings having inner
diameters of 2.5 inches. The standard penetration samplers are 2.0 inches in diameter with an inner
diameter of 1.5 inches: Undisturbed samples were removed from the sampler and placed in moisture
sealed containers in order to preserve the natural soil moisture content. Bulk samples were obtained
from the excavation spoils and samples were then transported to our laboratory for further
observations and testing.
Sladden Engineering
4
Vicinity Map
Proposed Big House Apartments
NEC Washington Street & Darby Rc
La Quinta, California
Sladden Engineering
Project Number: 544-3432 1 Date: I
North
1JV THE ClTr OF L,4o2(J11Vr,4 COLljV7r OF RIVER SIOZ STATE OF CALIFORNIA
PREZ,ffflNAR-r SITE PLAN
PARCEL 3 OF TRACT -97i3l
.......... ...........
ell
49,7.
A
------------
............
........ ......
Approximate Boring Locations
Proposed Big House Apartments / Parcel 3 of Tract 27131
NEC Washington Street & Darby Road / La Quinta, California
Date: 9-23-03 Borine
No. 1 Job No.: 544-3432.
5
3
s.
o
o
�o
DESCRIPTION
REMARKS
A"
ri
U
C4
t°
°
o
a U
0
_
Sand: Grey, fine grained
SP
s
-
6/8/12
102
0.5
---
4% passing #200
10
_
10/16/24
---
0.5
---
5% passing#200
1s
_
_
17/22/32
102
0.5
---
6% passing #200
20X
13/21/30
Sand: Brown,
SP/SM
---
0.5
---
11%passing #200
slightly silty, fine grained
25
_
12/12/13
Sand: Grey, fine grained
SP
---
0.5
--
7% passing #200
_
12/16/23
Sand: Brown,
SP/SM
---
0
---
10% passing #200
-
slightly silty, fine grained
ss
18/25/30
0.5
---
10% passing k00
ao
19/19/27
Sand: Grey, fine grained
. SP
---
0.58
---
5% passing #200
45
-
-
14/17/21
Sand: Brown,
SP/SM
---
0.5
---
9% passing #200
_
slightly silty, fine grained
50
14/22/35
Sand: Grey, fine grained
SP
-
0.5
-
5% passing #200
_
- Recovered Sample
Total Depth = 51.5'
- .
® Disturbed Sample
Note: The stratification lines
No Bedrock.
No Groundwater
55
TStandard Penetration
represent the approximate
boundaries between the soil types;
Sample
the transitions may be gradual.
Proposed Big House Apartments / Parcel 3 of Tract 27131
NEC Washington Street & Darby Road / La Quinta, California
Date:
9-23-03
BorinLy No.
2 Job No.: 544-3432
3
�o
DESCRIPTION
�
`�'
REMARKS
�
a�
A�
ri
U
W
,
a
Proposed Big House Apartments / Parcel 3 of Tract 27131
NEC Washington Street & Darby Road / La Quinta, California
Date: 9-23-03 Borin2 No.
3 Job No.: 544-3432
DESCRIPTION
REMARKS
0
-
Sand: Brown,
SP/SM
-
slightly silty, fine grained
5
4/5/7
---
0.5
---
8% passing #200
10
7/8/14
0.5
---
8% passing #200
15
-
8/16/20
103
0.5
---
10% passing #200
:9/12/20
20
_
y
"
0.5
---
8% passing #200
-
-Recovered Sample
Total Depth = 21.5'
No Bedrock
.
® Disturbed Sample
No. Groundwater
25
30
-
35
�
A
40
-
a
45
50
Note: The stratification lines
55
represent the approximate
boundaries between the soil types;
the transitions may be gradual.
Proposed Big House Apartments / Parcel 3 of Tract 27131
'NEC Washington Street & Darby Road / La Quinta, California
Date: 9-23-03 Boriniz No.
4 Job No.: 544-3432
rr
DESCRIPTION
°
A
o
REMARKS
0
_
Sand: Brown,
SP/S
_
slightly silty, fine grained
-5
7/11/16
"
108
0.5
---
12% passing #200
10
6/8/12
---
---
---
Unrecovered sample due to tree root
15
10/16/19
Sand: Grey, fine grained
SP
104
0.5
---
5% passing #200
20
7/12/15
0.5
--
6% passing #200
-
-Recovered Sample
Total Depth = 21.5'
No Bedrock
-
Disturbed Sample
No Groundwater
25
30
35
40
45
50
_
Note: The stratification lines
55
represent the approximate
boundaries between the soil types;
the transitions may be gradual.
Proposed Big House Apartments / Parcel 3 of Tract 27131
NEC Washington Street & Darby Road / La Quinta, California
Date: 9-23-03 BorinLy
No.
5 Job No.: 544-3432
3
DESCRIPTION
H
A
o
c.
REMARKS
y
U
0
_
Sand: Brown,
SP/S
_
slightly.silty, fine grained
s
4/6/8
Silty Sand: Grey brown,
SM
100
0.5
---
22% passing #200
_
fine grained
10
Sand: Brown,
SP/S
_
7/10/11
slightly silty, fine grained
102 1
0.5
---
10% passing #200
M
-
- Recovered Sample
Total Depth = 1 1.5'
No Bedrock
-
No Groundwater
15
'
20
25
30
35
40
45
50
_
Note: The stratification lines
55
represent the approximate
-
boundaries between the soil types;
the transitions may be gradual.
Proposed Big House Apartments / Parcel 3 of Tract 27131
NEC Washington Street & Darby Road / La Quinta, California
Date: 9-23-03 Borin2
No.
6 Job No.: 544-3432
i
DESCRIPTION
>1A
o
REMARKS
0
Sand: Brown,
Sp/SM
slightly silty, fine grained '
5
10/10/13
"
"
100
0.5
12% passing 9200
10
_
6/10/16
" "
"
99
0.5
---
9% passing #200
6/7/11
---
1.0
-
15% passing #200
20
11/16/28
"
"
108
0.5
---
7% passing #200
-
- Recovered Sample
Total Depth = 21.5'
No Bedrock
® Disturbed Sample
No Groundwater
25
_
30
s
35
40
4
45
50
-
a
Note: The stratification lines
55
represent the approximate
boundaries between the soil types;
the transitions may be gradual.
Proposed Big House Apartments / Parcel 3 of Tract 27131.
NEC Washington Street & Darby Road / La Quinta, California
Date: 9-23-03 Borin2
No.
7 Job No.: 544-3432
DESCRIPTION
A
o
a
REMARKS
A
on
U
4
rn
U
°
Sand: Brown,
SP/SM
slightly silty, fine grained
s
-
11/16/18
105
0.5
12% passing #200
io
7/14/14.
102
0.5
11
11% passing #200
-
-
- Recovered Sample
Total Depth = 11.5'
No Bedrock
-
No Groundwater
15
20
25
30
35
40
45
50
Note: The stratification lines
55
represent the approximate
boundaries between the soil types;
the transitions may be gradual.
Proposed Big House Apartments / Parcel 3 of Tract 27131
NEC Washington Street & Darby Road / La Quinta, California
Date: 9-23-03 Borin2
No,
8 Job No.: 544-3432
o
DESCRIPTION
A
o
a.
REMARKS
A
ri
U'
r°
U
0
-
Sand: Brown,
SP/SM
-
slightly silty, fine grained
5
8/16/20
103
0.5
---
9% passing #200
10
_
14/18/28
106
0.5
---
10% passing #200
1s
-
15/18/29
110
-
0.5
---
11 % passing #200
:16/19/20
20
101
0.5
---
12% passing #200
-
- Recovered Sample
Total Depth = 21.5'
No Bedrock
No Groundwater
25
30
35
40
45
50
Note: The stratification lines
55
represent the approximate
boundaries between the soil types;
the transitions may be gradual.
APPENDIX B
Laboratory Testing
Laboratory Test Results
y
s - T
Sladden Engineering,
APPENDIX B
LABORATORY TESTING
Representative bulk and relatively undisturbed soil samples were obtained in the field and returned
to our laboratory for additional observations and testing. Laboratory testing was generally
performed in two phases. The first phase consisted of testing in order to determine the compaction of
the existing natural soil and the general engineering classifications of the soils underlying the site.
This testing was performed in order to estimate the engineering characteristics of the soil and to
serve as a basis for selecting samples for the second phase of testing. The second phase consisted of
soil mechanics testing. This testingincluding consolidation, shear strength and expansion testing
was performed in order to provide a means of developing specific design recommendations based on
the mechanical properties of the soil.
CLASSIFICATION AND COMPACTION TESTING
Unit Weight and Moisture Content Determinations: Each undisturbed sample was weighed and
measured in order to determine its unit weight. A small portion of each sample was then subjected
to testing in order to determine its moisture content. This was used, in order to determine the dry
density of the soil in its natural condition. The results of this testing are shown on the Boring Logs.
Maximum Density -Optimum Moisture Determinations: Representative soil types were selected for
maximum density determinations. This testing was performed in accordance with the ASTM
Standard D1557-91, Test Method A. The results of this testing are presented graphically in this
appendix. The maximum densities are' compared to the field densities of the soil in order to
determine the existing relative compaction to the soil. This is shown on the Boring Logs, and is
useful in estimating the strength and compressibility of the soil.
Classification Testing Soil samples were selected for classification testing. This testing consists of
mechanical grain size analyses and Atterberg Limits determinations. These provide information for
developing classifications for the soil in accordance with the Unified Classification System. This
classification system categorizes the soil into groups having similar engineering characteristics. The
results of this testing are very useful in detecting variations in the soils and in selecting samples for
further testing.
SOIL MECHANIC'S TESTING
Direct Shear Testing: One bulk sample was selected for 'Direct Shear Testing. This testing
measures the shear strength of the soil under various normal pressures and is used in developing
parameters for foundation design and lateral design. Testing was performed using recompacted test
specimens, which were saturated prior to testing. Testing was performed using a strain controlled
test apparatus with normal pressures ranging from 800 to 2300 pounds per square foot.
Expansion Testing: One bulk sample was selected for Expansion testing.. Expansion testing was
performed in accordance with the UBC Standard 18-2. This testing consists of remolding 4-inch
diameter by 1-inch thick test specimens to a moisture content and dry density corresponding to
approximately 50 percent saturation. The samples are subjected to a surcharge of 144 pounds per
square foot and allowed to reach equilibrium. At that point the specimens are inundated with
distilled water. The linear expansion is then measured until complete.
Sladden Engineering
Proposed Big House Apartments / Parcel 3 of Tract 27131
NEC Washington Street & Darby Road / La Quinta, California
Date: 9-23-03 Borine
No.
9 Job No.: 544-3432
A
o
ri
�
U
o
1,:4
DESCRIPTION
a
to
U
o
o U
'REMARKS
0
-
_
10
6/8/14
9/14/17
Sand: Brown,
slightly silty, fine grained
SP/SM
101
98,
0.5
0.5
---
--
14% passing #200
7% passing #200
_
-
-
15
20
25
30
35
40
45
50
_
55
- Recovered Sample
i
Total Depth = 11.5'
No Bedrock
No Groundwater
Note: The stratification lines
represent the approximate
boundaries between the soil types;
the transitions may be gradual.
Maximum Density/Optimum Moisture
ASTM D698/D1557
Project Number: 544-3432 October 24, 2003
Project Name: Darby Rd. ASTM D-1557 A
Lab ID Number: - Rammer Type: Machine
Sample Location: Bulk 1 @ 0-5'
Description: Sand
Maximum Density: 111 pcf
Optimum Moisture .10.5%
' Sieve Size % Retained
3/4"
3/8"
#4
145
140
135
130
,
u
n
125
w
c
a�
A
120
L
A
115
110
105
100
mam�Mmma mmkb'
0 5 10 15. 20 25
Moisture Content, %
Max Density Sladden Engineering Revised 12/03/02
DIRECT SHEAR TEST
1.8
1
1.6
N I I 1
1.4
1.2
I I I 1
1.0
�4 .8 1
1 , .
r1� I 1 1
6 1
�•J . I I 1 I
� 1 1
4 I I I 1
2 soo ' ' 1
I I I
I I I
I I
0 '
0 :2 .4 .6. .8• 1.0 1.2 1.4 1.6 1.8
NORMAL LOAD (KIPS / FOOI 2 )
0=32.0
c = 120 psf
where 0 _ Shear Angle
c — Cohesion - Boring ] @ 0 - 5'
+' Proposed Bighouse Apartments
NEC Washington Street & Darby Road
La Quinta, California
Sladden Engineering
DATE: 10729-03 JOB NO.: 544-3432
Gradation
ASTM C117 & C136
P1:oject Number:
544-3432
October 24, 2003
Project Name:
Darby Rd.
Sample ID:
Bulk 1 @ 0-5'
Sieve
Sieve
Percent
Size, in
Size, mm
Passing
1"
25.4
100
3/4"
19.1
100
1/2"
12.7
100
3/8"
9.53
100
#4
4.75
100
#8
2.36
100
#16
1.18
100
#30
0.60
94
#50
0.30
63
#100
0.15
36 '
#200
0.074
11
100
90
80
70
on 60
50
40
30
20
10
ITT
Tr I
100:0 10.0 1.0 0.1 0.0 0.0
Sieve Size, mm
Gradation
Sladden Engineering
Revised 11/20/02
Gradation
ASTM C117 & C136
Project Number: 544-3432 October 24, 2003
Project Name: Darby Rd.
Sample ID: Boring 3 @ 20'
Sieve
Sieve
Percent
Size, in
. Size, mm
Passing
1".
. 25.4
100
3/4"
19.1
.100
1/2"
12.7
100
3/8" '
9.53
100
#4
4.75
100
#8
_ 2.36
100
#16
1.18
100
#30
0.60
96
#50
0.30
76
#100
0.15
36 "
#200
-0.074
8
ii1111■1 1111M■■rHM INI ■IIIIII■■■IIIIII■■■
iiii■■�iiiilii■■iiiiii �■iiiiiii■■iiiiii■■�
•' iiiiii■■iiiiii■■iiiiii■� iiiiii■■iiiiii■■a
' 11111IMMINEIIIIIINEEM111111O■■ �IIIIII■■■IIIIII■■■
liiiim■■iiiill■■■iiiill■■ 11111I ■■■iINIMI■■
IIII�■■■IIIII�■■®IIIII�■■ �����I�■■■IIIII�■■■
1111�■■■IIIII�■■■11111�■■ \IIIII�■■■IIIII�■■■
' iiiiii■■�uiiii■■iiiiii■■ �iiii■■ENIIIIIIi■■EN
IIIII�■■■IIIII�■■■11111�■■■�►11�■■�IIIII�■■■
CIIl1�■■■IIIII�■■■IIIII�■■■1 1�■■■11111�■■■
Gradation Sladden Engineering Revised 11/20/02
}
Project Number: 544-3432
Project Name: Darby Rd.
Sample ID: Boring 5 @ 10'
t
Sieve
Size, in.
3/4"
1/2"
3/8"
#4
#8.
#16
#30
#50
#100
#200
f
Gradation
ASTM C117 & C136
k
Sieve
Size, mm
25.4
19.1
12.7
9.53
4.75
2.3 6.
1.18
0.60
0.30
0.15
0.074
Percent
Passing
100
100
100
100
100
lOQ
GO
98
68
33
10
October 24, 2003
100
90
80
70
on 60
Cd 50
a
40
30
20
10
0
100.0 10.0 1.0 0.1 0.0 0.0
Sieve Size, mm
r
Gradation Sladden Engineering
Revised 11/20/02
L
1.
Gradation
ASTM C117 & C136 i
Project Number: 544-3432 October 24, 2003
Troject Name: Darby Rd.
Sample ID: Boring 7 @ 10'
Sieve
Sieve
Percent
Size, in
Size, mm
Passing
1"
.25.4
100
3/4"
19.1
100 -
1 /2"
12.7
100
3/8"
9.53
100
#4
- 4.75
100
#8
2.36
100
#16
1.18
100
#30
0.60
92
#50
0.30
51
#100
0.15 -
31
#200
0.074
11
" 111111■I 1111111■W inp1N■■■11111I■■■111111■■■
. , 11111I■■■ININIM■■III! I■■■INIII■■■111111■■■
11111I■■■INHIM■■1111 M■■■11111M■■■111111■■■
C1111I■■■11111M■■■11111!■■■111I1I■■■111111■■■
1111...■IIIII�■■■1111111■■■11111�■■■11111�■■■
11111I■■■111111■■■11111�■■■11111I■■■INUMM■■
11111■■■11111M■■■11111 \■■IIIIIN■■■11111I■■■
IIIII�■■■11111�■■■IIIII� �■■11111�■■■IIIII�■■■
. •' �1111�■■■11111�■■■IIIII� �■■IIIIIS■■■IIIII�■■■
1111�■■®IIIII�■■■11111�� ■IIIII�■■®11111�■■■
C1111�..■IIIII�■■■IIIII� ®IIIIIO■■■IIIII�■■■
'' liliii■■�iiiiii■■�iiliii■ �iiiiii■■�iiiiii■■�
CIIIIi■■■11111�■■■IIIII�■■ 11111�■■■IIIII�■■■
i111..■■IIIII�■■■IIIII�■■ IIIII�■■■IIIII�■■■
' iiiilii■■�iiiiii■■�iiiiii■■ �iiii■■�iiiiii■■■�
Illli■■■IIIII�■■■IIIII�■■■1 �11�■■■11111�■■■
III III■■■IIIII�■■■11111�■■■1�11�■■■IIIII�■■®
IIII1�■■■u 1■1S■■■Illl1■■■ull1�■■■
Gradation Sladden Engineering Revised l v20/02
f
1_ •
Expansion Index
ASTM D 4829/UBC 29-2
Job Number: 544-3432 Date: 10/24/03
Job Name: Darby Rd. Tech: Jake
Lab ID:
Sample ID: Bulk l @ 0-5'
Soil Description: Sand
Wt of Soil + Ring:
585.0
Weight of Ring:
179.0
Wt of Wet Soil:
406.0
Percent Moisture:
9%
Wet Density, pcf: •123.0
Dry Denstiy, pcf: 112.9
% Saturation: 49.3
Expansion Rack #
Date/Time 10/27/03 7:00 a.m.
Initial.Reading 0.500
Final Reading 0.500
Expansion Index 0
(Final -Initial) x 1000
EI Sladden Engineering
Revised 12/10/02
ANAHEIM TEST LABORATORY
3008 S. ORANGE AVENUE
SANTA ANA, CALIFORNIA 92707
PHONE (714) 549-7267
TO: SLADDEN ENGINEERING:
6782 STANTON AVE. SUITE -A DATE: 1 0/02/03
BUENA PARK, CA. 90621
Ro. No. Chain of Custody
Stopper No.
ATTN: BRETT/DAVE tab. No. A-3885
Specification:
Material: SOIL
PROJECT: #544-3432
BULK 1 @ 0-5'
ANALYTICAL REPORT
CORROSION SERIES
SUMMARY OF DATA
pH SOLUBLE SULFATES SOLUBLE CHLORIDES MIN. RESISTIVITY
per CA. 417 per CA. 422 per CA. 643
ppm ppm ohm -cm
i
6.9 74 1,126 600 max
4S4PECL'y
PO
FORA9 lit
1
, r
APPENDIX C
1997 UBC Seismic Design Criteria
October 28, 2003
-12-
Project No._544-3432
03-10-69 5
1997 UNIFORM BUILDING CODE SEISMIC DESIGN INFORMATION
The International Conference of Building Officials 1997 Uniform Building Code contains substantial
revisions and additions to the earthquake engineering section in Chapter 16. Concepts contained in
the code that will be relevant'to construction of the proposed structures are summarized below.
Ground shaking is expected to be the primary hazard most likely to affect the site, based upon
proximity to significant faults capable of generating large earthquakes. Major fault zones considered
to be most likely to create strong ground shaking at the site are listed below.
Fault Zone
Approximate Distance
From Site
Fault Type
(1997 UBC)
San Andreas
7.9 km
A . .
San Jacinto
35.7 km
A
Based on our field observations and understanding of local geologic conditions, the soil profile type
judged applicable to this site is So, generally described as stiff or dense soil. :The site is located
within UBC Seismic Zone 4. The following table presents additional coefficients and factors relevant
to seismic mitigation for new construction upon adoption of the •1997 code.
Near -Source
Near -Source
Seismic
Seismic
Seismic
Acceleration
Velocity
Coefficient
Coefficient
Source
Factor, Na
Factor, Ny
Ca
Cv
San Andreas.
1.1
1.4
0.44Na
0.64Nv
San Jacinto
1.0
1.0
0.44Na
0.64Nv
Sladden Engineering
***********************
* *
* E Q F A U L.T
* *
* Version 3.00
* *
***********************
DETERMINISTIC ESTIMATION OF
PEAK ACCELERATION FROM".DIGITIZED FAULTS
JOB NUMBER: 544-3432
DATE: 10-20-2003
JOB NAME: Darby Road & Washington Street
La Quinta, California
CALCULATION NAME: Test Run Analysis
FAULT -DATA -FILE NAME: CDMGFLTE.DAT
SITE COORDINATES:
SITE LATITUDE: 33.7333
SITE LONGITUDE: 116.3008
SEARCH RADIUS: 100 mi
ATTENUATION RELATION: 5) Boore et al. (1997) Horiz. - SOIL (310)
UNCERTAINTY (M=Median,. S=Sigma): M Number of Sigmas: 0.0'
DISTANCE MEASURE: cd_2drp
SCOND: 0
Basement Depth: 5.00 km Campbell SSR: Campbell SHR:
COMPUTE PEAK HORIZONTAL ACCELERATION
FAULT -DATA FILE USED: CDMGFLTE.DAT
MINIMUM DEPTH VALUE (km): 0.0
---------------
EQFAULT SUMMARY
---------------
-----------------------------
DETERMINISTIC SITE PARAMETERS
-----------------------------
Page 1
-------------------------------------------------------------------------------
I
(ESTIMATED MAX. EARTHQUAKE EVENT
APPROXIMATE I -------------------------------
ABBREVIATED I
DISTANCE I
MAXIMUM I
PEAK
IEST. SITE
FAULT NAME I
mi
(km) 1EARTHQUAKEI
SITE
(INTENSITY
I
I
MAG.(Mw) I
ACCEL. g
------====1=====____
IMOD.MERC.
SAN ANDREAS - Coachella 1
4.9(
7.9)1
7.1 1
0.391
1 X
SAN ANDREAS - Southern 1
4.9(
7.9)1
7.4 1
.0.458
1 X
BURNT MTN. 1
15.3(
24.6)1
6.4 1
0.128.
1 VIII
EUREKA PEAK 1
16.3(
26.2)1
6.4 1
0.122
1 VII
SAN ANDREAS - San Bernardino 1
16.6(
26.7)1
7.3 1
0.194
1 VIII
SAN JACINTO-ANZA 1
22.2(
35.7)1
7.2 1
0.148
1 VIII
SAN JACINTO-COYOTE CREEK 1
22.5(.
36.2)1
6.8 •1
0.118
1 VII
PINTO MOUNTAIN 1
28.0(
45.0)1
7.0 1
0.111
1 VII
EMERSON So. - COPPER MTN. 1
30.1(
48.4)1
6.9 1
0.100
1 VII
LANDERS 1
30.4(
49.0)1,
7_3 1
0.122,
1 VII
PISGAH-BULLION MTN..-MESQUITE LK 1
32.7(
52.6)1
7.1 1
0.104
1 VII
NORTH FRONTAL FAULT ZONE (East) 1
35.2(
56.7)1
6.7 1
0.097
1 VII
SAN JACINTO-SAN JACINTO VALLEY 1
35.4(
57.0)1
6.9 1
0.088
1 VII
SAN JACINTO - BORREGO 1
37.,3(
60.1)1
6.6 1
0.072
1 VI
JOHNSON'VALLEY (Northern) 1
41.3(
66.4)1
6.7 1
0.070
1 VI
EARTHQUAKE VALLEY 1
41.4(
66.6)1
6.5 1
0.063
1 VI
CALICO - HIDALGO 1
43.2(
69.5)1
7.1 1
0.084
1 VII
BRAWLEY SEISMIC ZONE 1
43.3(
69.7)_1
6.4 1
0.058
1 VI
ELSINORE-JULIAN 1
44.4(
71.4)1
7.1 1
0.082
1, VII
LENWOOD-LOCKHART-OLD WOMAN SPRGSI
47.0(
75.6)1
7.3' 1
0.087
1 VII
NORTH FRONTAL FAULT ZONE (West) 1
47.3(
76.2)1
7.0 1
0.090
1 VII
ELSINORE-TEMECULA 1
47.8(
76.9)1
6.8 1
0.066
1 VI
ELMORE RANCH 1
50.8(
81.7)1
6.6 1
0.057
1 VI
ELSINORE-COYOTE MOUNTAIN 1
53.2(
85.6)1.
6.8 1
0.061
1 VI
HELENDALE _ S. LOCKHARDT 1
54.9(
88.3)1
7.1 1
0.070
1 VI
SUPERSTITION MTN. (San Jacinto) 1
55.6(
89.5)1
6.6 1
0.053
1 VI
SUPERSTITION HILLS (San Jacinto)1
56.4(.
90.8)1
6.6 1
0.052
1 VI
SAN JACINTO-SAN BERNARDINO 1
57.2(
92.1)1
6.7 1
0.055
1 VI
ELSINORE-GLEN IVY 1
60.5(
97.4)1
6.8 1
0.055
1 VI
CLEGHORN 1
64.3(
103.5)1
6.5 1
0.045
1 VI
IMPERIAL 1
70.6(
113.6)1
7.0 ►
0.054
1 VI
CUCAMONGA 1
72.2(
116.2)1-
7.0 1
0.065
1 VI
CHINO -CENTRAL AVE. (Elsinore) 1
73.1(
117.7)1
6.7 I
0.055
1 VI
LAGUNA SALADA 1
73.7'(
118.6)1
7.0 1
0.053
1 VI
NEWPORT-INGLEWOOD (Offshore) 1
76.1(
122.5)1
6.9 1
0.049
1 VI
ROSE CANYON 1
76.3(
122.8)1
6.9 1
0.049
1 VI
WHITTIER 1
77.2(
124.3)1
6.8 1
0.046
1 VI
SAN ANDREAS - Mojave I
81.1(
130.5)1
7.1 1
0.052
1 VI
SAN ANDREAS - 1857 Rupture I
81.1(
130.5)1
7.8 1
0.075
1 VII
SAN JOSE � I
84.1(
135:3)1
6.5 1
0.044
1 VI
------------------------------
DETERMINISTIC SITE PARAMETERS
-----------------------------
Page 2
I
(ESTIMATED MAX. EARTHQUAKE EVENT
I
APPROXIMATE 1=
-------- ----------------------
ABBREVIATED I
DISTANCE I
MAXIMUM I
PEAK
JEST. SITE
FAULT NAME I
mi.
(km) JEARTHQUAKEI
SITE
JINTENSITY
I
I
MAG.(Mw) I ACCEL.
------____
g
IMOD.MERC.
GRAVEL HILLS - HARPER.LAKE 1
86.3(
138.9)1
6.9. 1
0.044
1 VI
SIERRA MADRE 1
86.9(
139.9)1
7.0 1
0.056
1 VI
ELYSIAN PARK THRUST 1
89.4(
143.8)1
6.7 1
0.047
1 VI
CORONADO BANK 1
91.7(
147.5)1
.7.4 1
0.055
I VI
NEWPORT-INGLEWOOD (L.A.Basin) 1
93.7(
150.8)1
6.9 1
0.041
1 V
CLAMSHELL-SAWPIT 1
95.4(
153.6)1
6.5 1
0.040
I V
COMPTON THRUST 1
96.3(
154.9)1
6.8 1
0.047
1 VI
BLACKWATER 1
98.2(
158.1)1
6.9 1
0.040
1 V
PALOS VERDES 1
99.2-(
159.6)1
7.1 1
0.044
1 VI
-END OF SEARCH- 49 FAULTS FOUND
WITHIN
THE SPECIFIED SEARCH
RADIUS.
THE SAN ANDREAS - .Coachella
FAULT IS CLOSEST TO THE
SITE.
IT IS ABOUT 4.9 MILES (7.9 km) AWAY. .
LARGEST MAXIMUM -EARTHQUAKE SITE ACCELERATION:•0.4575 g
CALIFORNIA FAULT'MAP
Darby Road & Washington Street / La Quinta
1•7 !
STRIKE -SLIP FAULTS
5) Boore et al. (1997) Horiz. -SOIL (310)
M=5 M=6 M=7 M=8
i
.1
.001
1 10 100
Distance [adist] (km)
c�
L
DIP -SLIP' FAULTS
5) Boore et al. (1997) Horiz. = SOIL (310)
M=5 M=6 M=7 M=8
I
001
1
10 100
Distance [adist] (km)
�:• tilt
J
BLIND -THRUST FAULTS
5) Boore et al..
(1997)
Horiz.
- SOIL ( I U)
M=5*
M=6'
M=7 M=8
o
.1
c�
a�
U
U
Q .01
.001
1
10 100"
Distance fadist] (km)
MAXIMUM EARTHQUAKES
Darby Road & Washington Street / La Quinta.