Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Mediterra Apartments TR 27131 - Title 24
TITLE 24 REPORT Title 24 Report for: Mediterra Maint. Office • La Quinta, CA r Project Designer: Humphreys and Associates 5350 Alpha Road • Dallas, TX 75240 (972) 701-9444 Report,P:repared. By: TAD Engineering TAD Engineering' 4 4633 E. Bond Ave. Orange, CA 92869 CITY C LA QUINTA (714) 595-0375 . BUILDING & SAFETY DEPT. APPROVED L FOR CONSTRUC TION TE BY .6 S • E Job Number: _ DEC-1 4 2006 Date: BY 11 /29/2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergySoo 3.1 By EnergySoft Job Number: User Number: 5787 c TABLE OF CONTENTS. Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form ENV-MM Envelope Mandatory Measures 11 Form MECH-MM Mechanical Mandatory Measures 12 c EnergyPro 3.1 By EnergySoft Job Number: User Number: 5787 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF-1 PROJECT NAME DATE Mediterra Maint. Office 11/29/2006 PROJECT ADDRESS La Quinta Building Permit # PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Humphreys and Associates (972) 701-9444 DOCUMENTATION AUTHOR TELEPHONE Checked by/Date TAD Engineering (714) 595-0375 Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA 460 Sq.Ft. CLIMATE ZONE 15 BUILDING TYPE ® NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ❑ ADDITION ALTERATION EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using the performance compliance approach. DOCUMENTATION AUTHOR SIGNATURE DATE TAD Engineering The Principal Designers hereby certify that the proposed building design represented in the construction documents and modelled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. ❑ 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENVA Required Forms PRINCIPAL ENVELOPE DESIGNER -NAME SIGNATURE LIC. NO. DATE Hu hre s and Associates LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Lighting Compliance Not In The Scope Of Required Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures MECH-1 MECH-2 MECH-3 Required Forms PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATURE LIC. NO. DATE TAD Engineering InitiationI Run Time: 9 3.0 •0 Code: 1164834427 EnergyPro 3.1 By Energysoft User Number: 5787 Job Number: Page:3 of 13 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF- DATE Mediterra Maint. Office 11 /29/2006 :] ANNUAL SOURCE ENERGY USE SUMMARY kBtu/s ft- r Standard Proposed Compliance ENERGY COMPONENT Design _ Design . Margin Space Heating Space Cooling . - Indoor Fans Heat Rejection Pumps & Misc: Domestic Hot Water Lighting Receptacle Process TOTALS: 3.91 2.61 1.30 106.30 98.48 7.83 . 31.30 30.65 0.65 0.00 0.00 0.00 0.00 0.00 0.00 '17.39 17.39 0.00 5s.7o 58.70 0.00 \ 25.43 25.43 0.00 24304 23326 978 [E Standard ■ Proposed sp-H.W.g spot. Coo" . • H.0 R4.dWn poops & We OHN ug.m9 Rx.ptade process 0 10 20 30 40 50 80 70 80 90 100 k8tu/saB-yr Percent better than Standard: 4.0% i 4.0% excluding process) i BUILDING COMPLIES GENERAL INFORMATION - Building Orientation Number of Stories Number of Systems Number of Zones North 0 deg .i ' 1 . 1 Conditioned Floor Area 460 sgft. Unconditioned Floor Area '0 scift. s. Conditioned Footprint Area ' 460 sqft. Standard Proposed LEEDTm Energy A Atmosphere Credit Lighting Power Density 2.000 wiscff. - 2.000 wisgff. Savings vs. Title 24 4.s6% Prescriptive Env. Heat Loss .112 Btuth 79 Bw/h Energy Performance Credit2 0 Points Prescriptive Env. Heat Gain 13,622 Btu/i}F 6,675 Btuk}f ~ 1. excludes process and receptacle 2. see LEER table 8-c or 8•d Remarks: a '` Run Initiation Time: 11/29/0613:07:07 Run Code: 1164834427 EnergyPro 3.1 By EnergySoft • User Number: 5787 - Job Number: ^ µ PageA of 13 PERFORMANCE, CERTIFICATE OF COMPLIANCE - Part 3 of 3 PERF-1 PROJECT NAME Mediterra Maint. Office ,DATE - 11/29/2006 ZONE INFORMATION System Name ' Zone Name Occupancy Type Floor Area (sgft.) Inst. LPD (W/sf)l Port. LPD ,, (W/sf)l Ctrl. Credits (W/sf)2 Tailored LPD x (W/sf) 3 Proc. Loads , `pN/sf) Maint. Maint. Office Exhibit Display& Museum 460 '2.000 # ,.• 'A • 1 1 ri Notes: 1. See LTG-1 (items marked with asterisk, see LTG-2 by others) 2. See LTG-3 3. See LTG hems above-requirespecial documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp Run Initiation Time: 11 29/0613:07:07 Run Code: -1164834427 EnergyPro 3.1 By EnergySoft User Number: 5787 Job Number: Page:5 of 13 ENVELOPE COMPLIANCE SUMMARY Performance ENV-1 PROJECT NAME DATE Mediterra Maint. Office 11/29/2006 OPAQUE SURFACES # Surface Type Framing Type Area Ufac. Act. Azm. Solar Gains Tilt y/N Form 3 Reference Location I Comments 1 Roof Wood 460 0.031 0 0 X11 I R-30 Root R.30.2x4.24 Maint. Office 2 all Wood 207 0.088 270 90 X11 JR-13Wall W.13.2x4.16 Maint. Office 3 Wall Wood 180 0.088 90 90 X11 JR-13Wall .13.2x4.16 Maint. Office 4 Wall Wood 85 0.088 180 90 x1l IR-13Wall .13.2x4.16 Maint. Office 5 Door None 63 0.146 180 90 X11 I Insulated Metal Door Maint. Office 6 Door None 20 0.581 180 90 X11 I Hollow Metal Door Maint. Office 7 Wall Wood 180 0.088 270 90 X11 JR-13Wall W.13.2x4.16 Maint. Office FENES TION SURFACES Site Assembled Glazing unecx oox it doming is — iuu,uuu sqn or ct-A ana — 1u,uuu sgrt verucai giaztng men rvrKU cemncauon is requires. Follow NFRC 100-SB Procedures and submit NFRC Label Certificate Form. # Type Area -Fac. Act. Azm. SHGC Glazing Type Location / Comments 1 Window 12 0.600 180 0.65 Double Clear Defaul NMaint. Office EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LEMMA Dist. Len, Hgt. Dist en. H t. 1 None 0.76 Run Initiation29/06 13:07:07 Rull Code:1164834427 EnergyPro 3.1 By Energysoft User Number: 5787 Job Number: Page:6 of 13 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME - DATE Mediterra Maint. Office 11/29/20( YSTEM FEATURES SYSTEM NAME TIME CONTROL . SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION ' OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH3, COLUMN 1 HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION R-VALUE COOLING DUCT LOCATION R-VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE Programmable Switch Heatino & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Outside Air Cert. Gravity No Economizer 69 cfm Heat Pump 7.74 HSPF Split DX 9.8 SEER / 9.8 EER = MITSUBISHI " ELECTRONICS MSHI2NN Yes r Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No CODE TABLES: Enter code from table below into columns above. NOTE TO FIELD z.. . Pr MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME Mediterra Maint. Office DATE 11 /29/2006 CHILLER AND TOWER SUMMARY Efficiency Tons PUMPS Equipment Name Equipment Type City. Tot. City GPM BHP Motor Eff. Drive Eff. Pump Control BOILERU Energy Factor or Recovery Efficiency Standby Loss or Pilot TANKINSUL. System Name System Type Distribution Type Qty Rated Input (Gals.) Vol. Ext. R-Val. CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type Qtv. Output Aux kW Eff. Ou ut Sensible Eff iciency Economizer Type MITSUBISHI ELECTRONICS Split DX 1 13,500 0.0 7.74 HSPF 12,900 9,030 .8 SEER / 9.8 EER No Economizer CENTRAL SYSTEM FAN SUMMARY SUPPLY FAN RETURN FAN System Name I Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. MITSUBISHI ELECTRONICS Constant Volume Draw -Through 1,050 0.33 77.0°,6 100.0% none EnerpvPro 3.1 BY EnergySoft User Number. 5787 Job Number: Page:8 of 13 1 (MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2 1 PROJECT NAME Mediterra Maint. Office DA'11 /29/2006 CFM CFM I BHP I Mot IDEft. e BASEBOARD Type Output Room Name Qty. CFM BHP Motor Eff. Drive Eff. Room Name Qty. CFM BHP w Motor Eff. Drive Eff. 3.1 Dn Time: 11/29/0613:07:07 Rui User Number: 5787 Job Number: of 13 MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE Mediterra Maint. Office 11/29/2006 MECHANICAL E ON o ©© o 0 0© a o 0 0 ZONEWSTEM Maint. Office Maint. r i AREA BASIS COND. MIN. AREA CFM CFM (SF) PER SF (B x C) 460 0.50 230 OF PER CFM OPLE PERSON I (ExF) REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOF AIR CFM VAV MIN. RATIO TRANS FER AIR 230 69 161 230 69 C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H-J). I EneruvPro 3.1 By EnerovSoft User Number: 5787 Job Number: Page:10 of 13 1 ENVELOPE MANDATORY MEASURES ENV-MM NAME Mediterra Maint. Office DATE 11 /29/2006 DESCRIPTION ` Designer - Enforcement 0 § 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3 F § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. X] § 117(a) All Exterior.Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. 0 § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and " fire doors). FX]§ 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U-value'according to NFRC procedures. R § 118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R-value of no less than R-11 between framing members. R • EnergyPro 3.1 By EnergySoft User Number: 5787 Job Number: _, Page: 11 of 13 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM (PROJECT NAME DATE Mediterra Maint. Office 1 11/29/2006 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies 0 § 111 Any appliance for which there is a California standard established In the Appliance Efficiency Regulations will comply with the applicable standard. § 115(a) Fan type central furnaces shall not have a pilot light. - 0 § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within NVAC equipment, shall be insulated in accordance with Standards Section 123. § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or ❑ § 122(e)iB An occupancy sensor to control the operating period of the system; or ❑ § 122(e)1C A 4-hour timer that can be manually operated to control the operating period of the system. § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. ❑ § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. ® § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 05 degrees F or higher. Where used'for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. , a§ 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance ❑ 1 supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 3.1 By EnergySoft User Number: 5787 Job Number: Page:12 of 13 MECHANICAL MANDATORY MEASURES Part 2 of 2 'MECH-MM PROJECT NAME DATE Mediterra Maint. Office 11/29/2006 Description Designer Enforcement Ventilation FX]§ 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. ' § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. n § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. § 121(f)1 Air Balancing:. The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or § 121(t)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the j installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licensed C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that.quantity on a readily accessible display divice; or ❑. § 121(f)4 Another method approved by the Commission. c Service Water Heating Systems El § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. a § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. X] § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 6.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a ' maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self -closing valves; and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self -closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). ' Self -closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro 3.1 By EnergySoft User Number. 5787 Job Number: Page:13 of 13 CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG - PROJECT NAME DATE PROJECT ADDRESt. r :1^: Y? PRINCIPAL DESIGN LI N TELEPHONE — 3zS DOCUMENTATION t PHONE GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE BUILDING TYPE ESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTELIMOTEL GUEST ❑ CONDITIONED SPACES UNCONDITIONED SPACES ❑ INDOOR I OUTDOOR SIGNS PHASE OF CONSTRUCTION NEW ❑ ADDITION ❑ ALTERATION METHOD OF COMPLIANCE ❑ PERFORMANCE ❑ COMPLETE BUILDING ❑ AREA CATEGORY ❑ TAILORED ❑ COMMON LIGHTING STATEMENT OF COMPLIANCE This Carfificate of Compliance fists fhe building features and performance spetiflcatiorts need to comply with Title 24, Parts 1 and 6 of the California Code of RegulaWrts. This certificate applies only to building 119t0V requirements. The Prtncipa f Lighting Desk hereby certifies that the proposejewEfthany d ftresented in this set of construction documents i4 �isl4tent with the other corn Hance forms and worksheets, With the spedficationother calculations submitted with this pemtit application, The proposed building has been designed to meet IgMhhg requirements costale parts of Sections 110. 119.130-132. 146. 148. & 149 of Title 24, Part 6. ❑ The plans & specifications meet the rewremen«s of Part s (Sections %-iwa). ❑ The irstatlation certificates meet the rests of Part 6 (10.103a 3). ❑ The operation & maintenance information meet the requirements of Part 6 (10-103c). Please check one: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professlors Code to sign fhh document as the person responsible for Its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. ❑ 1 affirm that I am eligible under the provision of Division 3 of the Bushhess and Professions Cade by section 65372 or 6737.3 to sign this document as the person responsible for Its preparation; and that I am a licensed contractor performing this work. ❑ t affirm that I am eligible under Dirlsbn 3 of the Buss and Professions Code to sign this document because it pertains to a sbuutise or type of wok described as expusuant to Business err r bee Cq� Cttans 5537,1i538 and 6737.1. +/ ❑ Indicate location on plans of Note Block1for Mandatory Measure. LIGHTING COMPLAINCE FORMS S WORKSHEETS (check box B wofkaheat Is Included) ❑ LTG-1-C, Parts 1 of 4 and 2 of 4 Certificate Of Compliance. ;art 1 of 4 and 2 of 4 are required for all submittals ❑ LTG-1-C, Part 3 of 4 Comte of Compliance. Part 3 of 4 submittal is required only If Control Credits are claimed ❑LTw-c. Part4 of 4 Certificate of Compliance. Pad 4 of 4 ere ❑ LTG•2-C inted" Lighting Schedulerl h e u r Portable Lighting Worlafhed SA . ❑ LTG-" Lighting Controls Credit Woksheet APPROVED ❑ LTG-S-C Interior Lighting PowerAllwranoe FOR CONSTRUCTION ❑ LTG4i•C Tailored Method Worksheet ❑ LTG-7-C Room Cavity Ratio Workshe et DATE klav ❑ LTG$C Common Lighting System Method Wc rksheet ❑ LTG-s c Line Voltage Track Ligh*V Worftheat ❑ OLTG4-C ISkjnr. (See OLTG4-C Sign Woiksheet In Chapter 6, Outdoor Lighting and Signs Chapter) 2005 Non►esidential Compliance Forms Apri12005 g&�o P-W Z— CERTIFICATE OF COMPLIANCE(Part 2 of 4) LTG-1-C INSTALLED INTERIOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES INSTALLED WATTS INSTALLED LIGHTING, CONDITIONED SPACES (From LTG-2-C) PORTABLE UGtfnNG (From LTG-3-C) + LIGHITNG CONTROL CREDIT, CONDITIONED SPACES (From LTG-4-C) CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG-2-C) UGHITNG CONTROL CREDIT, UNCONDITIONED SPACES (From LTG4.C) UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER ALLOWED INTERIOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (from LTG-S C) ❑ AREA CATEGORY METHOD (from LTG�C) ❑ TAILORED METHOD (from LTGdC) LL0 WED WTA ALLOWED LIGHTING POWER ALTERNATE COMPLIANCE ❑ PERFORMANCE METHOD ❑ COMMON LIGHTING SYSTEM (from LTG-8-C) ALLOWED INTERIOR LIGHTING POWER FOR UNCONDITIONED SPACES (From LTG-5C) Watts MANDATORY LIGHTING MEASURES FOR INTERIOR LIGHTING AND DAYLIT AREAS, MANDATORY INTERIOR AND DAYLIGHTTNG AUTOMATIC counni-s CONTROL TYPE (Auto Time Switch. Dimminig, Pfiotosensor. etc. ✓ N Control Is for NOTE TO FIELD CONTROL LOCATION (Room A Area #, or Des on CONTROL IDENTIFICATION SPACE CONTROLLED Lists the location of Cal6dled Ikjhb 2005 Nonresidential Compliance Forms April2005 INTERIOR LIGHTING .SCHEDULE (Part 1 of 2) LTG-2-C PROJECT 6-000,4� DATE /set Db INSTALLED LJGHTiNG POWER FOR CONDA1bNED SPACES . r.I P.M. ti �_Imo 11 2005 Nonresidential Compliance Forms PAGE TOTAL BUILDING TOTAL (sum of a9 pages) + PORTABLE LIGHTING (From LTG3-C) + CONTROL CREDIT (from LTG4-C) ADJUSTED ACTUAL WATTS Apn72005 f o�� INTERIOR, LIGHTING SCHEDULE • (Part • ti __ • ti -: rtM .. ,,MOT,�arnAm�a� 2W5 Nonresidential Compliance Forms BUILDING TOTAL (sum of all pages) + CONTROL CREDIT (from LTG4-C + 92 ADJUSTED ACTUAL WATTS + April 2005 • - lb-tVZIATR/eM, Ooi1PLEiEBULLD[ttCs lAElttOD—oOND I . 1 F• / .• 1=1 Fes, c . 'h1 II. . �1 '• Mom.. • • ii SPACES - - wArrs � u. LawEu aun.onte CATEGORY (From § tas rase t4") pmm � WATTSstop. w�r r• • I r1 1I • �r r0. 0 e • -Ir ce .I ce .I iT n Ln CU cD 0 CD ,'t rn Lij 0 CD C-) Ir 0 ENTERIOR A I.L IZI-I'Q[.: I LUMINAIRES WITI I LAMPS RATEDOVER I()() W. k*FI*S sl LALL 11. WE ' . k LA \ Ip i-*imc. kci* oi., LEAST 60 1.1 **\ 11: F' PR WATT OR BE CONTROLLED BY A.MOTHYN SENSOR. ALL RL(2UIRED OUIDOOR LUMINAIRES TIL-10'USL LA.\ , HIS GREXI'LlUITIAN 175 WAYIS IN IIARDSCAPF AREAS. BUILDING E'NTRANCI'S. ALL SALES .AND S CAN01111', S, 01 TTDOOR MINING AND OUTI)OOR SALES AREAS SHALL BE: URMFTYPE, LUMINAIRES. All. 14:101ANENTLY INSTALLED OUTI)MR LIGHTING SHALL 131: 1 CONTROLLED BY P110TOCONTIMI, OR AI'1)110VI'-.1)..kS'I'IZON(').\;I]C'Al.'['I,\11-- SWITCH. All R);Q(,[Rl-"I) OUTDOOR 1,1011TINO INC1,111M.NG 11111,I)IN(i FACADES. PARNING LOTS. GARAGES.. SALESAND NON-SALL CANOPIES :AND oi;,rj)()(')It SALES AREAS WHEIRETWO OR \10.11E LUMINAIRE.S AREIJ�TSFA). AUTOMATIC CONTROLSARE REQI.*,]RrD TO PRON.-'IDr-, THE OWNER WITH REDUCE''I'll]: LIGHTING BY 111ITNOT I-"NCI:I:I)IN(; NONRESIDEN L4]L, RDOOR MANDATORY MEASURES Building Lighting Shut-off The building lighting shut-off system consists of an automatic time switch, with a zone for each floor. 'or the building is separately metered and exempt from the shut-off requirement. Override for Building Lighting Shut-off The automatic building shut-off system is provided with a manual accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. Automatic Control Devices Certified All automatic control devices specified are certified; all alternate equipment shall be certified and installed as directed by the manufacturer. Fluorescent Ballast And Lummauvs Certified All fluorescent fixtures subject to certification ans specified for the projects are certified. Individual Room/Area Controls Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls_ Uniform Reduction for Individual Rooms All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with Muhi-level switching for uniform reduction of lighting within the room. Daylit Area Control All rooms that are:greater than 250 square feet and contain windows and skylights, that allow for the effective use of daylight in the area shall have 50% of the lighting power in each daylit area controlled by a separate switch; or The effective use of daylight throughout cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of year is included on plans. SAT-24 DommentsWonresidentW-indoor-mand-measures.doc .v CERTIFICATE OF COMPLIANCE (Part 1 of 2) OLTG-1-C 1 :a4. 3XV MNC M TYPE ' ' ' ❑ OUTDOOR LIGHTING ❑ OUTDOOR SIGNS ❑ INDOOR SIGNS PHASEaF CONSTRUCTIMI NEWCONSTRUCTION ❑ ADnmoNs ❑ AumAmow sTATBU NT eF COUPLI ICE. This Ceriirate of Canpimw ffsfs outdoor QgIM y system sindkederis need to omVty wkh Title 24. Parts 1 and 6 of the CafffaNa Cade of Regidatiors. 7bb aerfrcaI epptles cry to bt"V NI5-n9 requkenents. The doounerftfl n preparer hereby cuffies that the domanentation i `aaaxale and complete. The Pdndpal ughtlrU Designer AerebY oertffies ttrat tt►e pruDosed okaAf'ti�Mig 6d signs design represented in Oft set of carabudlon doatnenls is consislenl with Ore corer carrVft= tams and world. to spedfications. and rMh any o0m calalatiom subrrdtted with Ois pemil appketion The proposed WA ing has been designed to meet Be fighting mgwements contained 1n the appieable parts of Sedbm 110. 119.130 Oroo 13Z 146. and 149 of Tile 24. Part 6. Please +0' one: )d-i hereby affam that 1 em eigibie under the provisions of 131visio n 3 of the Business and Professions Code to sign Oda doannrent as One person responsVA fa ire ptepar and that 1 an licensed in One State of Cafdartda as a dv6 engineer or electrical enghwer. or 1 am a doetsed arddecL ❑ 1 aft. Drat 1 am etigHis undo Be p owlsbns of OM M 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign Ws d=Xne nt as One person responsible for pa preparaf mr, and OW i am a liaased ca*actor performing this work ❑ 1 et6m that 1 em eigVAe under the provisions of Division 3 of the Ek and PnAmsions Code to so this doomant becmme $ pertains to a stnrdum or type of wok described as ezenpl purshmnt to Business and Professions Code Sections 5537.5530 and 6M.1. INSiRUC11oNs To APPut;ANT OUTDOOR Liammilf. cow umm a wommmm s (,, box award hed is 4ndrded) For hwhxbats on lire use of dtls and all EneW E fidwW Standards oampliarroe fans, pibe refer to be Nortresk erttia l M pubbslted by the Cafdomia Energy Cammisskm fA OLTG-I-C CeddicateofCornpliance. Requited on plans for a8 submittals for outdoor lghting. Part2 of 2 maybe incoipwaW In schedules on the Either LTG-1-0 or OLTCr1-C may be used for signs as 1. Use LTG-1-C ff the project solely of indoor signs 2. Use LTG-1-C if the project - lists of indoor fighting, and outdoor or indoor signs, but no other outdoor fighting. & Use 0LTG4-C If the project consists solely of outdoor signs 4. Use OLTG-t-C If the project consists of outdoor ligh ft and bxbm or outdoor signs, but no other atdoor bd OLTG-2-C LIGHTING COMPLIANCE SUMMARY. Apppcable Parts required for ALL outdoor ig4hfing allowances (Except for ❑ OLTG3-C AREA CALCULATIONS 1MDRKSHEETS. Appkable parts mWred for aQ a*kw area catakeffiors. ❑ OLTG4-CSIGN GfMNG COMPLIANCE Required for ON hbemaity and mftffwly �d signs. for bath indoor and 2005 Nonnesidertfiad Compfance Forms Aped 2005 , -jam CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG-1-61 9QSmum R um= L1GH m Pomim FOR commONm AND UNCONDmomw SPACES INSTALLED WATTS INSTALLED LIGHTING. COWnONED SPACES (Fmm LTG 2Lq PORTABLE LIGHTING (From LTG3-C) + mminm CONTROL CREDM CONDITIONED SPACES (Fmm LTG+C) COND"MNED FACE ADJUSTED INSTALLED LIGHTING POKIER INSTALLED LIGHTING. UtONED SPACES (From Llir2-C) Gr LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (Flom LTG -Q UNMIDRIONEDSPACE ADJUSTED WSTALLED LIGHTING POWER ALLOWED INTERIOR LIGHTING POWER FOR CONDITIONED SPACES ✓ ❑ comPLum Btmmm METHOD prom LTG&q ❑ AREA CATEGORY Mom) prom LTe4q ❑ TAWORED MEn= (from LTGdC) ❑ PERFORMANCE METHOD - ❑ COWAOR LJGHTTNG SYSTMffn n L7041�q ALLt7WED INTERIOR LIGHTING POWER FOR UNCOIDITIONLD SPACES Pm LTG S.C) Watts RUMA70RY UGHTM MEASURES FOR MTERIOR LIWMG AND DAYLJTAREAS MANDATIORY INTERIOR AND DAVLIGHTIKG AUTOMATIC CONTROLS CONTROL TYPE ✓ CONTROL LOGA71011 (Auto Time Swkck SPACE CONTROLLED N Coff" is NOTE TO (Room 9. Am /. or OONTRIX Dkmnw , Lists tit@ location of for . RBA IDENTIRCA71014 PAotosensor. eta) conhotled fkjhts 2M N mvesldenW Compftnoe Forms Apd 2W5 -Eras P FiFFM W-M WN WN mo- :- ME -. - Category- Crable 1474y_ OMEN: De'ription _ 81= min ® sue==®mom NNWMITPFI=_- - 2005 Nonresidential Compliance Forms April 2005 ~ c 1446 P..002/002 F-4`1•T j IONS R SPECIFICAT FEB-10-200;6 .09:55AM;_ FROM- SF-:,L-F CONTAINE •COMPAC, r �2c. 51 1 /2' . 60�''•. 4,0- a soa 0 Zo 0. — _ t>arX� a^ire 5`'y3/2y� � ��� SPE:CLFICA:TIONS`(.Are a1,1'th� same f♦or Unipaks; 15,2�.0,2_,5,�0,•. •. ' • �.,MRa.r)th4 uC A: •hC �$t' ,n`'8.Ak F. 'eh !'R .�• a ,: •w. •7 ! v r c +• u••�fist -mwi =; 1 $BCIY 156 CrY29 59 x33' 9 45 216 90 240 34D�� 38psi ^ S Ys;Se ITM - s Cp rrr4atrie�rr, atarr,E BF . sy(t61 i �CoAlC1` QC a aritFR} s ~i�G •�(� r �:Ek:+QS!$ S''''1de9c> �.`srNk►St7�sn�°t i .f�. .-.....� 2o06(max ) 3/]:8'.... 3•lt•s• 34se`c. 3/,9'j' - 3./•8" 1f4°.......(2c)4° Bo.re.z.36.croketic Mediterra Apartments La Quinta, California. Title-24 Energy Compliance Report RECEIVED For: LUCAS cif NkRAI. t;f)WRAC IN Whiteco Residential, .LLC _ 350 N. Lassalle Street, Ste. 1100 - Chicago, IL 60610 (312) 645-9108 . . }M CITY OF f A-QUINTA . BUILDING & SAFETY DEPT. APPR®VE® FOR CONSTRUCTION Prepared By: AI) Engineering 1,,4f,0 Y- Mechanical, Plumbing & Energy Consultant 4633 E. Bond Ave. Orange, CA 92869 (714) 595-0375 r a { Contents " ❑ Cover Page o Contents ❑ Summary of Energy Conservation Features ❑ Building Type ✓ Energy Form CF-1 R ✓ Energy Form C-2R ✓ Energy Form MF-1 R ✓ . ✓ Fa ✓ ❑ Building Type IV ✓ Energy Form CF-1 R ✓ Energy Form C-2R . ✓ Energy Form MF-1 R __❑ -..Building Type_I_V_-R ✓ Energy Form CF-1 R ✓ Energy Form C-2R ✓ Energy Form MF-1 R " o Clubhouse ✓ Energy Form PERF-1 ✓ Energy Form ENV-1 ✓ Energy Form MECH-1 ✓ Energy Form MECH-2 ✓ Energy Form MECH-3 ✓ Energy Form ENV-MM ✓ Energy Form MECH-MM 1 SUMMARY OF ENERGY CONSERVATION FEATURES (Building Type I, II, III, III-R, IV, and IV-R) Following the Performance Method of Compliance and using the energy features outlined below each building was able to meet the Residential Title 24 Energy Requirements set by the California Energy Commission (CEC). Using the approved MicroPas 6.01 Performance Calculation Software each building was modeled separately at all four orientations. The resulting energy use for the worst -case exposure was then compared to the allowed energy budget. Because the proposed energy budget was found to be lower than that allowed by the Standard Design Energy Budget; the building complied with the current Title 24 Residential Requirements using the following requirements: 1. R-30 insulation in attic space; 2. R-13 insulation in exterior wall; 3. R-4.2 duct insulation; 4. Vinyl framed with dual pane glass for all units; o Operable windows with U-value of 0.60. o Sliding glass door with U-value of 0.55. ❑ Solar heat gain for all windows and doors to be 0.55. 5. ' Combined Hydronic space and domestic hot water heating system with the following: ❑ Hydronic fan coil unit using First Company Air Handler. ❑ 10 S.E.E.R. DX cooling using York value line condensing unit.. ❑ 40 and 50 gallons water heater with minimum 40,000 Btuh input and an energy factor of 0.62 and 0.60. (Clubhouse Building) Following.the Performance Methodoof Compliance and using the energy features outlined below each building was able to meet the Residential Title 24 Energy Requirements set by the CEC. Using the approved Energy Pro 3.1 Performance Calculation Software to model the building. The resulting energy use was then compared to the allowed energy budget. Because the proposed energy budget was found to be lower than that allowed by the Standard Design Energy Budget the building complied with the current Title 24 Residential Requirements using the following requirements: 1. R-30 insulation in'attic space; 2. R-13 insulation in exterior wall; 3. R-4.2 duct insulation; 4. Metal framed with dual pane Low-E glass for all windows and doors; ❑ Operable windows with U-value of 0.49. ❑ Sliding glass door with U-value of 0.49. ❑ Solar heat gain for all windows and doors to be 0.40. 5. Heat pump heating and cooling with the following: o Heat pump air handler using York Air Handler. ❑ 12 S.E.E.R. Heat pump using York value line unit. Building Type I La Quinta, California J fl CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Project Title.......... Mediterra Bldg. I Date..01/27/04 09:26:49 Project. Address .......... Mediterra Apartments ******* --------------------- La Quinta, California *v6.01* I I Documentation Author... Huey Cao ******* I Building Permit # I TAD Engineering 1 1 4633 E. Bond Ave. I Plan Check / Date I Orange, CA 92869. 1 1 714-595-0375 1 Field Check/ Date I Climate Zone............ 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 'Standards by Enercomp, Inc. 1 MICROPAS6 v6.01 File-MEDIT_1 Wth-CTZ15S92 Program -FORM CF-1R I 1 User#-MP2350 User -TAD Engineering Run-Mediterra Apartments I ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- Conditioned Floor Area..... 13453 sf Building Type.............. Multifamily Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 14. Number of Stories.......... 2 Floor Construction Type.... Slab On Grade Glazing Percentage......... 13.8 % of floor area Average Glazing U-factor... 0.6 Btu/hr-sf-F Average Glazing SHGC....... 0.55 Average Ceiling Height..... 9 ft BUILDING SHELL INSULATION ------------------------- Comporient Frame Cavity Sheathing Total Assembly Type Type R-value R-value R-value U-factor Location/Comments ----------------------------------- -------------- ------------------------ Wall Wood R-13 R-0• R-13 0.088 NORTH, EAST, SOUTH WEST, NORTHEAST NORTHWEST Roof Wood R-11 R-19 R-30 0.031 Attic Door - Metal _R-O. Rcn./_a _R-O.. _ 0.,470_METAL DOOR SlabEdge None R-0 R-n/a F2=0.900 To Outside FENESTRATION ------------ Over- , Area U- Interior Exterior hang/ Orientation (sf) Factor SHGC Shading --------------- Shading -------------- Fins ----- -------------------- Window Front (N) ----- 342.0 ------ ------ 0.600 0.550 Standard Standard None Window Front (N) 24.0 0.600 0.550 Standard Standard Yes Door Front (N) 120.0 0.600 0.550 Standard Standard Yes Door Front (N) 96.0 0.600 0.550 Standard Standard Yes Window Left (E) 258.0 0.600. 0.550 Standard Standard None Window Left (E) 48.0 0.600 0.550 Standard Standard Yes Door Left (E) 20.0 0.600 0.550 Standard Standard Yes ,� Window Back (S) 362.0 0.600 0.550 Standard Standard None ` CERTIFICATE OF COMPLIANCE: RESIDENTIAL ------------ Page 2 CF-lR • Project Title.......... Mediterra Bldg, I Date..01/27/04 09:26:49 I MICROPAS6 v6.01 File-MEDIT_1 Wth-CTZ15S92 Program -FORM CF-1R --------------------------------------------------------_---------------------- User#-MP2350 User -TAD Engineering Run-Mediterra Apartments, FENESTRATION ------------ Over- Area U- Interior Exterior hang/ Orientation (sf) Factor SHGC Shading Shading Fins -------------------- Window ----- ------ --------------------- Back (S) 48.0 0.600 0.550 Standard -------------- Standard ----- Yes Window Right (W) 228.0 0.600 0.550 Standard Standard None Window Right (W) 48.0 0.600 0.550 Standard Standard Yes .Door Right (W) 80.0 0.600 0.550 Standard Standard 'Yes Door Right (W) 96.0 0.600 0.550 Standard Standard Yes Window Front (NE) 40.0 0.600 0.550 Standard Standard None Window Right (NW) 40.0 0.600 0.550 Standard Standard_ None SLAB SURFACES Area Slab Type (sf) Standard Slab 6496 HVAC SYSTEMS ------------ Refrigerant Tested ACCA Equipment Minimum Charge.and Duct Duct Duct Manual Thermostat 1. Type Efficiency Airflow Location R-value Leakage D Type Hydronic 0.745 AFUE n/a Conditioned R-4.2 No' No Setback ACSplit 10.00 SEER No Conditioned R-4.2 No No Setback WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type ------------ Heater Type Distribution Type System ------------------------------ ------ Factor -------- (gal) ------ R-value ------.---- HYDRONIC.1 , Storage Gas Standard 8 .62 40 R- n/a HYDRONIC.2 Storage Gas Standard 6 0.60 50 R- n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R Project Title.......... Mediterra Bldg. I Date..01/27/04 09:26:49 MICROPAS6 v6.•01 File-MEDIT_1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP2350 -----------------------------------------------------------------'-------------- User -TAD Engineering Run-Mediterra Apartments WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss Insulation Pilot System ------------ Efficiency Input ------------------------ Fraction ---------- R.-value Light ---------------------- HYDRONIC.1 Storage 0.76 40000 Btuh n/a R- n/a n/a HYDRONIC.2 Storage 0.76 40000 Btuh n/a R- n/a n/a HYDRONIC PIPING AND SPACE HEATING Pump Pipe Pipe Insulation Insulation_ Hydronic Hydronic Energy Length Diameter Thickness Conductivity System Type Delivery (Watts) (ft) (in) (in) (Btu/Hr-ft-F) HYDRONIC.1 Storage Combined FanCoil n/a 50 0.75 -0.375 0.023 HYDRONIC.2 Storage Combined FanCoil n/a 50 0.75 0.375 0.023 I SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on'the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building -with no orientation restrictions. This printout is for the front facing North. This building incorporates a Combined Hydronic Space and Water Heating System. This building incorporates non-standard Duct Location. This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** ** must be reported on the CF-6R installation certificate. *** This building incorporates non-standard Duct Location. I CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-lR Project Title.......... Mediterra Bldg. I Date..01/27/04 09:26:49 I' •MICROPAS6 v6.01 File-MEDIT_1 Wth-CTZ15S92 Program -FORM CF-lR I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments I REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and '6 'of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual- with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied'is indicated in the Special,Features Modeling Assumptions section. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... Name.... Huey Cao Company.,Humphreys & Partners Company. TAD Engineering Address. 5350 Alpha Road Address. 4633 E. Bond Ave. Dallas, TX 75240 Orange, CA 92869 Phone... 572-701-9636 Phone... 714-595-0375 License. - Signed.. Signed.. "�J �i7Z6 �- (date) (date) Name.... Title.... Agency.. Phone... Signed. I ..ENFORCEMENT_AGENCY (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF-lR Project Title.......... Mediterra Bldg. I Date..01/27/04 09:26:49 Project Address........ Mediterra Apartments ******* La Quinta, California *v6.01* I I Documentation Author... Huey Cao ******* I Building Permit # I TAD Engineering I 1 4633 E. Bond Ave. I Plan Check / Date I Orange, CA 92869 I 1 714-595-0375 I Field Check/ Date I Climate Zone........... 15 ------------ -------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- I MICROPAS6 v6.01 File-MEDIT_1 Wth-CTZ15S92 Program -FORM MF-lR i I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments I ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- Design- Enforce- er ment *150(a): Minimum R-19 ceiling insulation. �-3u 150(b): Loose fill insulation manufacturer's labeled R-Value. *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls).i3 *150(d): Minimum R-13 raised floor insulation in framed floors. 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. V 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. v� _. .11.6-.1.7..:. _Fenestr.atio.n.Products., Exjterior. Doors and .I.nfiltration/_ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. v� 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets Commission quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs- 1. Masonry and factory -built fireplaces have: 1 a. Closeable metal or glass door. MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF-1R -------------------_------------------------------------------------------------ ------------------------------------------------------------------------------- Project Title........... Mediterra Bldg. I Date..01/27/04 09:26:49 I MICROPAS6 v6.01 File-MEDIT_1 Wth-CTZ15S92 Program -FORM MF-1R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments I -------------------------------------------------------------- =----------------- b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. r% SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES -------------------------------------------------------------- Design- Enforce- er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ✓ 150(i): Setback thermostat on all applicable heating and/or cooling systems. ✓ 150(j): Pipe and Tank insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water system. 5. Cooling system piping below 55 degrees insulated. 6. Piping insulated between heating.source and indirect hot water tank. ✓_ *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and in- sulated, to meet the requirements of the 1998 CMC-sections 601, 603, and 604,-and standard 6-3; ducts insulated to a, minimum installed level of R-4.2 or enclosed entirely in-conditioned..sp,a.ce.. Openings shal.l,b,e sealed . with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or.tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems .and their components shall not -be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. V 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on -off j switch, weatherproof operating instructions, no electric MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 3 MF-1R Project Title.......... Mediterra Bldg. I Date..01/27/04 09:26:49 MICROPAS6 v6.01 File-MEDIT_1 Wth-CTZ15S92 Program -FORM MF-lR User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------ =------------------------------------------------- =---------- resistance heating and no pilot light. 2. System is installed with: a. At least 36 inches of pipe between filter and heater for.future solar heating., b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas -fired central furnaces,'pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances_ with pilot < 150 Btu/hr). LIGHTING MEASURES ----------------- Design- Enforce- er ment 150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to,the kitchen. / 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this requirement allowed in Sec. 150(k)2.; and recessed ceiling fixtures are IC (insulation•cover) approved. ✓ • COMPUTER METHOD'SUMMARY Page 1 C-2R ---------------- Project Title.......... Mediterra Bldg. I Date..01/27/04 09:26:49 Project Address....:... Mediterra Apartments ******* --------------------- La Quinta, California *v6.01* 1 1 Documentation Author... Huey Cao ******* I Building Permit # I TAD Engineering I I 4633 E..Bond Ave. I Plan Check / Date 1 Orange, CA 92869 I I 714-595-0375 I Field Check/ Date I Climate Zone........... 15 ---------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, 'Inc MICROPAS6 v6.01 File-MEDIT_1 Wth-CTZ15S92 Program -FORM C-2R 1 1 U3er#-MP2350 User -TAD Engineering Run-Mediterra Apartments 1 ------------------------------------------------------------------------------- ---------------------------- ---------------------------- MICROPAS6 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) Design Design Margin. - Space Heating.......... 1.19 0.90 0:29 = = Space Cooling.......... 31.91 29.05 2.86 = - Water Heating.......... 21.89 18.29 3.60 = = North Total 54.99 48.24 6.75 = j = Space Heating.......... 1.19 0.83 d.36 = = Space Cooling.......... 31.91 30.12 1.79 = - Water Heating 21.89 18.29 3.60 = = East Total 54.99 49.24 5.75 = = Space Heating.......... 1.19 0.77 0.42 = - Space Cooling.......... 31.91 29.38 •2.53 = = Water Heating.......... 21.89 18.29 3.60 = - South Total 54.99 48.44 6.55 = - Space Heating.......... 1.19 0.84 0.35 = = Space Cooling.......... 31.91 30.14 1.77 = - Water Heating 21.89 18.29 3.60 = = West Total 54.99 '49.27 5.72 = _ ***, Building complies with Computer Performance *** _ COMPUTER METHOD SUMMARY Page 2 C-2R ---. -- Project•Title.......... Mediterra Bldg. I Date..01/27/04 09:26:49. MICROPAS6 v6.01 File-MEDIT 1 Wth-CTZ15S92 Program -FORM C-2R I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments I ------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area..... 13453 sf Building Type .............. Multifamily Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 14 Number of Building Stories. 2 Weather Data Type.......... ReducedYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 121077 cf 6496 sf 13.8 % of floor area 0.6 Btu/hr-sf-F 0.55 9 ft BUILDING ZONE INFORMATION Floor ------------------------- # of Vent - Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage Zone Type (sf) (cf) Units itioned Type (ft) (sf) Credit HOUSE Residence 13453 121017 14.00 Yes Setback 8.0 Standard No OPAQUE SURFACES Area U- --------------- Insul Act Solar Form 3 Location/ Surface (sf) ------ factor ----- R-val ----- Azm Tilt --- ---- Gains ----- Reference =----------- Comments" ---------------- -------------- HOUSE 1 Wall 1668 0.088 13 0 90 Yes W.13.2X4.16 NORTH 2 Wall 1264 0.088, 13 90 90 Yes W.13.2X4.16 EAST 3 Wall 1768 0.088 13' 180 90 Yes W.13..2X4.16 SOUTH 4 Wall 1114 0.088 13 270 90 Yes W.13.2X4.16 WEST 5 Wall 68 0.088 13 45 90 Yes W.13.2X4.16 NORTHEAST 6 Wall 68 0.088 13 315 90 Yes W.13.2X4.16 NORTHWEST 7 Roof 6957 0.031 30 n/a 0 Yes R.30.2X4.24 Attic 8 Door 72 0.470 0 0 90 Yes •None- METAL DOOR 9 Door 48 0.470 0 90 90 Yes, None METAL DOOR 10 Door 144 0.470 0 180 90 Yes None METAL DOOR 11 Door 72 0.470 0 270 90 Yes None METAL DOOR COMPUTER.METHOD SUMMARY Page 3 C-2R Project Title........... Mediterra Bldg. I Date..01/27/04 09:26:49 I MICROPAS6 v6.01 File-MEDIT_1 Wth-CTZ15S92 Program -FORM C-2R I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments I ------------------------------------------------------------------------------- PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- HOUSE 12 SlabEdge 448 0.900 R-0 No To Outside FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade Orientation (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC ---------------------- ----- ----- ----- --- ---- -------------- -------------- HOUSE 1 Window Front (N) 342.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 2 Window Front (N) 24.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 3 Door Front (N) 120.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 4 Door Front (N) 96.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 5 Window Left (E) 258.0 0.600 0.550 90 90 Standard/0.76 Standard/0.68 6 Window Left (E) 48.0 0.600 0.550 90 90 Standard/0.76 Standard/0.68 7 Door Left (E) 20.0 0.600 0.550 90 90 Standard/0.76 Standard/0.68 8 Window Back (S) 362.0 0.600 0.550 180 90 Standard/0.76 Standard/0.68 9 Window Back (S) 48.0 0.600 0.550 180 90 Standard/0.76 Standard/0.68 10 Window Right (W) 228.0 0.600 0.550 27.0 90 Standard/0.76 Standard/0.68 11 Window Right (W) 48.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 12 Door Right (W) 80.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 13 Door Right (W) 96.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 14 Window Front (NE) 40.0 0.600 0.550 45 90 Standard/0.76 Standard/0.68 15 Window Right (NW) 40.0 0.600 0.550 315 90 Standard/0.76• Standard/0.68 OVERHANGS AND SIDE FINS ---Window-- ------Ov_erhang------ ---Left Fin--- ---Right Fin -- Area Left Rght Surface (sf) ----- Wdth ----- Hgth ----- Dpth ---- Hght ---- Ext ---- Ext ---- Ext ---- Dpth ---- Hght ---- Ext ---- Dpth ---- Hght ---- ----------- HOUSE 2 Window 24.0 6.00 4.00 5.00 1:00 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 120.0 3.00 8.00 -5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 96.0 6.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 48.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 7 Door 20.0 3.00 8.00 5.00 1.00 n/a n/a. n/a n/a n/a n/a n/a n/a 9 Window 48.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 48.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 12 Door 80.0 3.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 13 Door 96.0 6.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER.METHOD SUMMARY Page 4 C-2R Project Title.......... Mediterra Bldg. I Date..01/27/04'09:26:49 I MICROPAS6 v6.01 File-MEDIT_1 Wth-CTZ15S92 Program -FORM C-2R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments I ------------------------------------------------------------------------------- SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ HOUSE Standard Slab 6496 HVAC SYSTEMS ------------ Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type Efficiency Airflow Location R-value Leakage D Eff HOUSE ` Hydronic 0.745 AFUE n/a Conditioned R-4.2 No No 1.000 ACSplit 10.00 SEER No Conditioned R-4.2 No No 1.000 WATER HEATING SYSTEMS Number Tank -External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value ------------------------------------------ -------------- ---------------- HYDRONIC.1 1 Storage Gas Standard .8 .62 40 'R- n/a HYDRONIC.2 2 Storage Gas Standard 6 0.60 50 R- n/a WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery ..Rated:. Loss. Insulation. ..Pilot System Efficiency Input Fraction R-value . Light HYDRONIC.1 1 Storage 0.76 40000.Btuh n/a R- n/a n/a HYDRONIC.2 2 Storage 0.76 40000 Btuh n/a R- n/a n/a HYDRONIC PIPING AND SPACE HEATING --------------------------------- Pump Pipe Pipe Insulation Insulation Hydronic Hydronic: Energy Length•Diameter Thickness Conductivity System Type Delivery (Watts) (ft) (in) (in) (Btu/Hr-ft-F) HYDRONIC.3: 1 Storage Combined FanCoil n/a 50 0.75 0.375 0.023 HYDRONIC.2 2 Storage Combined FanCoil n/a 50 0.7'5 0.375 0.*023 f COMPUTER METHOD SUMMARY Page 5' C-2R Project Title.......... Mediterra Bldg. I Date..01727J04 09:26:49 --------------------------------------------------------------------------- I MICROPAS6 v6.01 File-MEDIT_1 'Wth-CTZ15S92 Program -FORM C-2R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is, for the front facing North. This building incorporates a Combined Hydronic Space and Water Heating System. This building incorporates non-standard Duct Location. This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** i *** must be reported on the CF-6R installation certificate. *** This building incorporates non-standard Duct Location. REMARKS MANDATORY MEASURES CHECKLIST:,RESIDENTIAL Page 2 MF-lR Project Title.......... Mediterra Bldg. II Date..01/27/04 14:12:32 MICROPAS6 v6.01 File-MEDIT_2 Wth-CTZ15S92 Program -FORM MF-lR I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. `f SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES -------------------------------------------------------------- Design- Enforce- er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ' ✓ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ✓ 150(i): Setback thermostat on all applicable heating and/or cooling systems. , 150(j): Pipe and Tank insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water system. S. Cooling system piping below 55 degrees insulated. 6. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and in- sulated, to meet the requirements of the 1998 CMC sections 601, 603, and 604, and standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely --in-eondit-i-oned_ space. Openings-s.hal-1 .be sealed.-__ with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on -off j switch, weatherproof operating instructions, no electric MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 3 MF-lR ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Mediterra Bldg. II Date..01/27/04 14:12:32 ------------------------------------------------------------------------------- MICROPAS6 v6.01 File-MEDIT_2. Wth-CTZ15S92 Program -FORM MF-lR I User#-MP2350' User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- resistance heating and no pilot light. 2. System is installed with: a. At least 36 inches of pipe between filter and heater' for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system -has directional inlets and a circulation pump time switch. 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr). LIGHTING MEASURES ----------------- Design- Enforce- er ment 150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one.of thealternatives to this requirement allowed in Sec. 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. COMPUTER METHOD SUMMARY Page l C-2R Project Title.......... Mediterra Bldg. II Date..01/27/04 14:12:32 Project Address........ Mediterra Apartments ******* --------------------- La Quinta, California *v6.01* I I Documentation Author... Huey Cao ******* I Building Permit # I TAD Engineering I 1 4633 E. Bond Ave. I Plan Check / Date I Orange, CA 92869 I I 714-595-0375 I Field Check/ Date 1 Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS.6 v6.01 for 2001`Standards by Enercomp, Inc. ------------------------------------------------------------------------------- I MICROPAS6 v6.01 File-MEDIT 2 Wth-CTZ15S92 Program -FORM C-2R 1 1 User#-MP2350 User -TAD Engineering Run-Mediterra Apartments I ------------------------------------------------------------------------------- ---------------------------- ---------------------------- MICROPAS6 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) Design Design Margin = = Space Heating.......... 1.83. 1.68 0.15 = = Space Cooling.......... 35.09 32.06 3.03 = = Water Heating.......... 21.45 17.90 3.55 = = North Total 58.37 51..64 6.73 = = Space Heating.......... 1.83 1.46 0.37 = = Space Cooling.......... 35.09 33.75 1:34 = = Water Heating.......... 21.45 17.90 3.55 _ = East Total 58.37 53.11 5.26 = = Space Heating.......... 1.83 1.38 0.45 = = Space Cooling.......... 35.09 33.66 1.43 = - Water Heating.......... 21.45 17.90 3'.55 _ = South Total 58.37 52.94 5.43 = Space -Heating .......... 1.83 1.57 0.26 = = Space Cooling.......... 35.09 33.77 1.32 = Water Heating........... 21.45 17.90 3.55 = = West Total 58.37 53.24 5.13 = *** Building complies with Computer Performance*** --------------------------------------------------- --------------------------------------------------- COMPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... Mediterra Bldg. II Date..01/27/04 14:12:32 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS6 v6.01 File-MEDIT_2 Wth-CTZ15S92 Program -FORM C-2R I I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments I ------------------------------------------------------------------------------- GENERAL.INFORMATION Conditioned Floor Area..... 9863 sf Building Type .............. Multifamily Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 10 Number of Building Stories: 2 Weather Data Type........... ReducedYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Raised Floor 1 88767 cf 2906 sf 14.7 % of floor area 0.6 Btu/hr-sf-F 0.55 9 ft BUILDING ZONE INFORMATION Floor ------------------------- # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage Zone Type -------------- (sf) ----- (cf) ------- Units ----- itioned ------- Type (ft) ----------- ----- (sf) Credit -------- --------- HOUSE Residence 9863 88767 10.00 Yes Setback 8.0 Standard No OPAQUE SURFACES Area U- --------------- Insul Act Solar Form 3 Location/ Surface (sf) factor R-val Azm Tilt Gains Reference Comments -------------- HOUSE ------ ----- ----- --- ---- ----- ------- ----- ---------------- _ .. _. 1 Wall 1492 0.088 13 0 90 Yes W.13.2X4.16 NORTH 2 Wall 985 0.088 13 90 90 Yes W.13.2X4.16 EAST 3 Wall 970 0.088 13 180 90 Yes W.13.2X4.16' SOUTH 4 Wall 865 0.088 13 270 90 Yes W.13.2X4.16 WEST 5 Wall 68 0.088 13 45 90 Yes W.13.2X4.16 NORTHEAST 6 Wall 68. 0.088 13 315 90 Yes W.13.2X4.16 NORTHWEST 7 Wall 856 0.088 13 0 90'No W.13.2X4.16 GARAGE WALL 8 Roof _6957 0.031 30 n/a 0 Yes R.30.2X4.24 Attic 9 Door 72 0.470 0 0 90 Yes None METAL DOOR 10 Door 24 0.470 0 90 90 Yes None METAL DOOR 11 Door 96 0.470 0 180 90 Yes None METAL DOOR 12 Door 48 0.470 0 270 90 Yes None METAL DOOR 13 Door 80 0.470 0 0 90 No None Solid Wood 16 Floor 3842 0.037 19 n/a 0 No FC.19.2X8.16 OVER GARAGE COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... Mediterra Bldg. II Date..01/27/04 14:12:32 ------------ --- - -------------------------------- I MICROPAS6 v6.01 File-MEDIT_2 Wth-CTZ15S92 Program -FORM C-2R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- HOUSE 14 SlabEdge 226 0.900 R-0 No, To Outside 15 SlabEdge 104 0.550 R-0 No TO GARAGE FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade Orientation (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC ---------------------- ----- ----- ----- --- ---- -------------- -------------- HOUSE 1 Window Front (N) 342.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 2 Window Front (N) 24.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 3 Door. Front (N) 80.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 4 Door Front (N) 96.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 5 Window Left (E) 189.0 0.600 0.550 90 90 Standard/0.76 Standard/0.68 '6 Window Left (E) 24.0 0.600 0.550 90 90 Standard/0.76 Standard/0.68 7 Door Left (E) 20.0 0.600 0.550 90 90 Standard/0.76 Standard/0.68 8 Window Back (S) 182.0 0.600 0.550 180 90 Standard/0.76 Standard/0.68 9 Window Back (S) 48.0 0.600 0.550 180 90 Standard/0.76 Standard/0.68 10 Window Right (W) 165.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 11 Window Right (W) 24.0 0.600 0.550 270 90 Standard/0.76 •Standard/0.68 12 Door Right (W) 80.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 13 Door Right (W) 96.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 14 Window Front (NE) 40.0 0'.600 0.550 45 90 Standard/0.76 Standard/0.68 15 Window Right (NW) 40.0 0.600 0.550 315 90 Standard/Q.76 Standard/0.68 OVERHANGS AND SIDE FINS ----------------------- ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght ----------- ----- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- HOUSE 2 Window 24.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 80.0 3.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 96.0 6.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 24.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 7 Door 20.0 3.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 48.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 24.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 12 Door 80.0 3.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 13 Door 96.0 6.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a IN COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... Mediterra Bldg. II Date..01/27/04 14:12:32 MICROPAS6 v6.01 File-MEDIT_2 Wth-CTZ15S92 Program -FORM C-2R l User#-MP2350 User-TAD.Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- SLAB SURFACES ------------- Area Slab Type (sf) HOUSE Standard Slab 2906 HVAC SYSTEMS ------------ Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type Efficiency Airflow Location R-value Leakage D Eff --------------------------------------------- ------------------------ ---- HOUSE Hydronic 0.745 AFUE n/a Conditioned R-4.2 No No 1.000 ACSplit 10.00`SEER No Conditioned R-4.2 No No 1.000 WATER HEATING SYSTEMS --------------------- Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value ------------------------------------------ -------------- ---------------- HYDRONIC.1 1 Storage Gas Standard 6 0.62 40 R- n/a HYDRONIC.2 2 Storage Gas Standard 4 0.60 50 R- n/a WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recov.er_y_._. -Rated-... ... _ ....-Los.s_..... _ _,Ins_ulation_ Pilot _. _.. . System Efficiency Input Fraction_ R-value Light ^ ------------ ----- -------------------------------------------------- HYDRONIC.1 1 Storage 0.76 40000 Btuh n/a R- n/a n/a HYDRONIC.2 2 Storage 0.7•.6 40000 Btuh n/a R- n/a' n/a HYDRONIC PIPING AND SPACE HEATING --------------------------------- Pump Pipe Pipe Insulation Insulation Hydronic Hydronic Energy Length Diameter Thickness Conductivity System Type Delivery (Watts) (ft) (in) (in) (Btu/Hr-ft-F) HYDRONIC.1 1 Storage Combined FanCoil n/a 50 0.75 0.375 0.023 HYDRONIC.2 2 Storage Combined FanCoil n/a 50 0.75 0.375 0.023 COMPUTER METHOD SUMMARY Page 5 C-2R ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Mediterra Bldg. II Date..01/27/04 14:12:32 -------------------------------------------------------------------------------- I MICROPAS6 v6.01 File- MEDIT 2 Wth-CTZ15S92 Program -FORM C-2R I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments -------------------------------------------------------------------------------- SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Combined Hydronic Space and'Water Heating System. This building incorporates non-standard Duct Location. This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION -------------------------- ***• Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be.reported on the CF-6R•installation certificate. *** This building incorporates non-standard Duct Location. REMARKS ti 13 Building Type III La Quinta, California t CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R ------------ Project Title........... Mediterra Bldg. III Date. .01/27/04 14:12:07 Project Address........ Mediterra Apartments ******* --------------------- La Quinta, California *v6.01* I I Documentation Author... Huey Cao ******* I Building Permit # I TAD Engineering I I 4633 E. Bond Ave. I Plan Check / Date I Orange, CA 92869 I I 714-595-0375 I Field Check/ Date Climate Zone........... 15 ------- ------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ---------- --------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS6 v6.01 File-MEDIT 3 Wth-CTZ15S92 Program -FORM CF-lR I I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments I ---------------------------------------------- -------------------------------- GENERAL INFORMATION ------------- Conditioned Floor Area..... 12426 sf Building Type.. ............. Multifamily Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 13 Number of Stories.......... 2 Floor Construction Type.... Slab On Grade Glazing Percentage......... 13.7 % of floor area Average Glazing U-factor... 0.6 Btu/hr-sf-F Average Glazing SHGC....... 0.55 Average Ceiling Height..... 9 ft BUILDING SHELL INSULATION ------------------------- Component Frame Cavity Sheathing Total Assembly Type Type R-value R-value R-value U-factor Location/Comments ------------------------------------------------- -------------_----------- Wall Wood R-13 R-0 R-13 0.088 NORTH, EAST, SOUTH WEST, NORTHEAST NORTHWEST GARAGE WALL Roof _Wo.o.d R-1,1 _ ..___._R-19. _R-30 _ ._.:_0 1031 Attic_ Door Metal R-0 R-n/a R-0 0.470 METAL DOOR Solid Wood SlabEdge None R-0 R-n/a F2=0.900 To Outside SlabEdge None R-0 R-n/a F2=0.550 TO GARAGE Floor Wood R-19 R-0 R-19 0.037 OVER GARAGE FENESTRATION ------------ Over- Area U- Interior Exterior hang/ Orientation (sf) Factor SHGC Shading Shading Fins -------------------- Window Front (N) ----- 342.0 ------ 0.600 ------ 0.550 --------------- Standard -------------- Standard ----- None Window Front (N) 24.0 0.600 0.550 Standard Standard Yes Door Front (N) 100.0 0.600 0.550 Standard. Standard Yes ? Door Front (N) 96.0 0.600 0.550 Standard Standard Yes CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2. CF-lR Project Title.......... Mediterra Bldg. III Date..01/27/04 14:12:07 I MICROPAS6 v6.01' File-MEDIT_3 Wth-CTZ15S92 Program -FORM CF-1R I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments I ------------------------------------------------------------------------------- FENESTRATION ------------ -Over- Area U- Interior Exterior 'hang/ Orientation (sf) Factor SHGC Shading Shading Fins Window Left (E) 189.0 0.600 0.550 Standard Standard" None Window Left (E) 24.0 0.600 0.550 Standard Standard Yes Door Left (E) 20.0 0.600 0.550 Standard Standard Yes Window Back (S) 341.0 0.600 0.550 Standard Standard None Window Back (S) 48.0 0.600 0.550 Standard Standard Yes Window Right (W) 219.0 0.600 0.550 Standard Standard None Window Right (W). 45.0 0.600 0.550 Standard Standard Yes Door Right (W) 80.0 0.600 0".550 Standard Standard Yes Door Right (W) 96.0 0.600 0.550 Standard Standard Yes Window Front (NE) 40.0 0.600 0.550 Standard Standard None Window Right (NW) 40.0 0.600 0.550 Standard Standard None SLAB SURFACES ------------- Area Slab Type (sf) Standard Slab 5469 HVAC SYSTEMS Refrigerant Tested ACCA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat Type Efficiency Airflow Location R-value Leakage D Type Hydronic 0.745 AFUE n/a Conditioned R-4.2 No No Setback -- -- - - "-ACSplit . _ _ . 10_0-0_ SEER . .. -No- ___. .C.ondit.i.one.d__ _R-4 .2.. _ No. .....No_ _._ Setback WATER HEATING SYSTEMS --------------------- Number Tank External in Energy Size Insulation Tank Type Heater -Type Distribution Type System ------ Factor -------- (gal) ------ R-value ---------- ------------ HYDRONIC.1 ----------- ------------------- Storage Gas Standard 8 0.62 40 R- n/a HYDRONIC.2 Storage Gas Standard 5 0.60 50 R- n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R ----------=-------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Mediterra Bldg. III Date..01/27/04 14:12:07 MICROPAS6 v6.01 File- MEDIT_3 Wth-CTZ15S92 Program -FORM CF-lR User#-MP2350 User -TAD Engineering Run-Mediterra Apartments WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss Insulation Pilot System ------------ Efficiency Input ------------------------ Fraction ------'---- R-value Light ---------------------- HYDRONIC.1 ` Storage 0.76 40000 Btuh n/a R- n/a n/a HYDRONIC.2 Storage 0.76 40000,Btuh n/a R- n/a n/a HYDRONIC PIPING AND SPACE HEATING Pump Pipe Pipe Insulation Insulation Hydronic Hydronic Energy Length Diameter Thickness Conductivity System Type Delivery (Watts) (ft) (in) (in) (Btu/Hr-ft-F) HYDRONIC.1 Storage Combined FanCoil n/a 50 0.75' 0.375 0'.023 HYDRONIC.2 Storage Combined FanCoil n/a 50 0.75 0.375 0.023 SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Combined Hydronic Space and Water Heating System. This building incorporates non-standard Duct Location. This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** **.*.verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and ***. *** must be reported on the CF-6R installation certificate. *** This building incorporates non-standard Duct•Location. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-lR, Project Title.......... Mediterra Bldg. III Date..01/27/04 14:12:07 -------------------- MICROPAS6 v6.01 File-MEDIT_3 Wth-CTZ15S92 Program -FORM CF-1R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- REMARKS COMPLIANCE STATEMENT -------------------- j This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be'built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER DOCUMENTATION AUTHOR - Name .... Name.... Huey Cao Company. Humphreys & Partners Company. TAD Engineering Address. 5350 Alpha Road Address. 4633 E. Bond Ave. Dallas, TX 75240 Orange, CA 92869 Phone... 972-701-9636 Phone... 714-595-0375 License. Signed... Signed. `��1E— -Z17lw (date) (date) ----------- -___ _EN.FORCEMEN.T _AGENCY--__. �_T_ _ _-.---•---._.-_.__. -- _ .-_.- _ -- -- -___ �_. Name.... Title. Agency.. Phone... - Signed.. (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF-lR Project Title........... Mediterra Bldg. III Date..01/27/04 14:12:07 Project Address........ Mediterra Apartments ******* --------------------- La Quinta, California *v6.01* 1 Documentation Author... Huey Cao ******* I Building Permit # I TAD Engineering I I 4633 E. Bond Ave. I -Plan Check / Date I Orange, CA 92869 _ 1 1 714-595-0375 1 Field Check/ Date 1 Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- 1 MICROPAS6 v6.01 File-MEDIT_3 Wth-CTZ15S92 Program -FORM MF-lR 1 User#-MP2350 User -TAD Engineering Run-Mediterra Apartments 1 ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- Design- er *150(a): Minimum R-19 ceiling insulation. f A` 150(b): Loose fill insulation manufacturer's labeled R-Value. *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors.. 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor -transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets insulation quality standards. Indicate type and form.' --..-_---11-6=17:--Fenestration-.P-roduet-s -Exterior -Doors a-nd- Inf-ilt-r.a-tion./ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage: 2. Fenestration products (except field fabricated) have . label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones'14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets Commission quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door V Enforce- ment MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF-lR Project Title.......... Mediterra Bldg. III Date..01/27/04 14:12:07 I MICROPAS6 v6.01 File-MEDIT_3 Wth-CTZ15S92 Program -FORM MF-1R I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. ✓ SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES -------------------------------------------------------------- Design= Enforce- er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. :6 150(i): Setback thermostat on all applicable heating and/or cooling systems. J 150(j): Pipe and Tank insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water system. 5. Cooling system piping below 55 degrees insulated. 6. Piping insulated between heating source and indirect hot water tank. ✓ *150(m): Ducts and Fans 1. All ducts -'and plenums installed, sealed and in- sulated, to meet the requirements of the 1998 CMC sections 601, 603, and 604, and standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely ___-in__c.o.ndit.i.one.d _s-pa.c.e..._ Openings._shal1 _be_sealed-__.__, with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such - tape is used in combination with mastic and drawbands. 2. Exhaust fan systems have backdraft or automatic dampers., 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. V 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on -off switch, weatherproof operating instructions, no electric J ♦ � MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 3 MF-lR Project Title.......... Mediterra Bldg. III Date..01/27/04 ------------------- 14:.12:07 I MICROPAS6 v6.01 •File-MEDIT_3 Wth-CTZ15S92 Program -FORM MF-1R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments -resistance heating and no pilot light. 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation . pump time switch. 115: Gas -fired central furnaces, pool heaters, spa heaters..or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot•< 150 Btu/hr),: LIGHTING MEASURES ----------------- Design- Enforce- er ment 150(k)l: Luminaires for general .lighting in kitchens shall, have lamps with an efficacy of 40'lumens/watt or greater for general lighting in kitchens. This general,lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. E.. 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps'with'an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this requirement' allowed in Sec. 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. V' COMPUTER METHOD SUMMARY Page 1 C-2R ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Mediterra Bldg. III Date..01/27/04 14:12:07 Project Address........ Mediterra Apartments ******* --------------------- La Quinta, California *v6.01* .I Documentation Author... Huey Cao ******* I Building Permit # I TAD Engineering I I 4633 E. Bond Ave. I Plan Check / Date I Orange, CA 92869 I I 714-595-0375 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp,•Inc. - ------------------------------------------------------------------------------ I MICROPAS6 v6.01 File-MEDIT_3 Wth-CTZ15S92 Program -FORM C-2R I I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- MICROPAS6 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) Design Design Margin = - Space Heating.......... 1.33 1.07 0.26 = - Space Cooling.......... 32.77 29.48 3.29 = = Water Heating.......... 21.98 18.30 3.68 = = North Total 56.08 48.85 7.23 _ = Space Heating.......... 1.33 0.99 0.34 = Space Cooling 32.77 30.71 2.06 = Water Heating.......... 21.98 18.30 3.68 = = East Total 56.08 50.00 6.08 = - Space Heating.......... ` 1.33 0.87 0.46 = = Spade Cooling.......... 32.77 30.00 2..77 = = Water Heating.......... 21.98 18.30 3.68 = = South Total 56.08 49.17 6.91 = _ -Space Heating....:..... 1.33 0.96 0.37 = = Space Cooling.......... 32.77 31.02 1.75 = = Water Heating........... 21.98 18.30 3.68 = = West Total 56.08 50.28 5.80 = *** Building complies with Computer -Performance *** COMPUTER METHOD SUMMARY Page 2 C-2R ------------------------------------------=------------------------------------ ------------------------------------------------------------------------------- Project Title.......... Mediterra Bldg. III Date..01/27/04 14:12:07 ------------------------------------------------------------------------------- MICROPAS6 v6.01 File-MEDIT_3 Wth-CTZ15S92 Program -FORM C-2R I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area..... 12426 sf Building Type .............. Multifamily Construction Type New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 13 Number of Building Stories. 2 Weather Data Type.......... ReducedYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage.....:... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 111834 cf 5469 sf 13.7 % of floor area 0.6 Btu/hr-sf-F 0.55 9 ft BUILDING ZONE INFORMATION r Floor ------------------------- # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage Zone Type (sf) (cf) Units itioned Type (ft) (sf) Credit -------------- HOUSE ----- ------- ----- ------- ----------- ----- -------- --------- Residence 12426 111834 13.00 Yes Setback 8.0 Standard No OPAQUE SURFACES Area U- --------------- Insul Act Solar , Form 3 Location/ Surface (sf) factor R-val Azm Tilt Gains Reference Comments HOUSE 1 Wall 1598 0.088 13 0 90 Yes W.13.2X4.16 NORTH 2 Wall 1051 0.088 'l3 90 90 Yes W.13.2X4.16 EAST 3 Wall 1417 .0.088 13 180 90 Yes W.13.2X4.16 SOUTH 4.Wall 1126 0.088 13 270 90 Yes W.13.2X4A6 WEST 5 Wall 68 0.088 13 45 90 Yes W.13.2X4.16 NORTHEAST 6 Wall 68 0.088 13 315 90 Yes .•W.13.2X4.16 NORTHWEST 7 Wall 520 0.088 13 0 90 No W.13.2X4.16 GARAGE WALL 8 Roof 6957 0.031 30 n/a 0 Yes R.30.2X4.24 Attic 9 Door 72 0.470 0 0 90 Yes None METAL DOOR 10 Door 48 0.470 0 90 90 Yes None METAL DOOR 11 Door 120 0.470 0 180. 90 Yes None METAL DOOR` 12 Door 72 0.470 0 270. 90 Yes -None METAL DOOR 13 Door 20 0.470 0 0 90 No None Solid Wood 16 Floor 1087 0.037 19 n/a 0 No FC.19.2X8.16 OVER GARAGE COMPUTER METHOD SUMMARY Page 3 C-2R r Project Title.......... Mediterra Bldg. III Date..01/27/04 14:12:07 -------------------------- MICROPAS6 v6.01 File-MEDIT_3 Wth-CTal5S92 Program -FORM C-2R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- PERIMETER LOSSES ---------------- Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- HOUSE 14 SlabEdge 360 0.900 R-0 No To Outside 15 S1abEdge 60 0.550 R-0 No TO GARAGE FENESTRATION SURFACES 7 -------------------- Area U- Act Exterior Shade Interior Shade Orientation (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC ---------------------- ----- ----- ----- --- ---- -------------- -------------- HOUSE 1 Window Front, (N) 342.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 2 Window Front (N) 24.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 3 Door Front (N) 100.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 4 Door Front (N) 96.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 5 Window Left (E) 189.0 0.600 0.550 90 90 Standard/0.76 Standard/0.68 j 6 Window Left (E) 24.0 0.600 0.550 90 90 Standard/0.76 Standard/0.68 7 Door Left (E) 20.0 0.600 0.550 90 90 Standard/0.76 Standard/0.68 8 Window Back (S) 341.0 0.600 0.550 180 90 Standard/0.76 Standard/0.68 9 Window Back (S) 48.0 0.600 0.550 180 90 Standard/0.76 Standard/0.68 10 Window Right (W) 219.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 11 Window Right (W) 45.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 12 Door Right (W) 80.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 13 Door Right (W) 96.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 14 Window Front (NE) 40.0 0.600 0.550 45 90 Standard/0.76 Standard/0.68 15 Window Right (NW) 40.0 0.600 0.550 315 90 Standard/0.76 Standard/0.68 OVERHANGS AND SIDE FINS ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght ----------- ----- ----- ----- ---- ---- ---- ---- --- ---- ---- ---- ---- ---- HOUSE 2 Window 24.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 100.0 3.00 8.00 5..00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 96.0 6.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a - 6 Window 24.0 6.'00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 7 Door 20.0 3.00 8.00 5.00 1.00 n/a n/a n/an/a n/a n/a n/a n/a 9 Window 48.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 45.0 6.00 4.00 5.00 1.00 n/a- n/a. n/a n/a n/a n/a n/a n/a 12 Door 80.0 3.00 8.00 5.00 1.00 n/a n/a n/a 'n/a n/a n/a n/a n/a 13 Door 96.0 6.00 8.00 -5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD SUMMARY Page 4 C-2R F Project Title.......... Mediterra Bldg. III Date..01/27/04 14:12:07 --------------- MICROPAS6 v6.01 File-MEDIT 3 Wth-CTZ15S92 Program -FORM C-2R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------ ------------------------------------------------ SLAB SURFACES -------------{ Area Slab Type (sf) HOUSE " Standard Slab 5469 HVAC SYSTEMS ------------ Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type ------------- Efficiency ----------- Airflow Location R-value --------------------------- Leakage, ----------------- D Eff ---- HOUSE Hydronic 0.745 AFUE n/a Conditioned R-4.2 No. No 1.000 ACSplit 10.00 SEER No Conditioned R-4.2 No No 1.000 WATER HEATING SYSTEMS Number Tank External ' in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value HYDRONIC.1 ' 1 Storage z Gas Standard 8 0.62 40 R- n/a HYDRONIC.2 2 Storage Gas Standard 5 0.60 50 R-•n/a WATER HEATING SYSTEMS DETAIL Standby Internal Tank --------- -------Reeowery- - •-Ra•t-ed--------Loss--- Insu-l-ation-.____.-7Pi.l.ot______ System Efficiency Input• Fraction R-value Light -------------------------------------------------------------------- HYDRONIC.1 1 Storage 0.76* 40000 Btuh n/a R- n/a n/a HYDRONIC.2 2 Storage 0.76 40000 Btuh n/a R- n/a n/a HYDRONIC PIPING AND SPACE HEATING --------------------------------- Pump Pipe Pipe Insulation Insulation Hydronic Hydronic Energy Length Diameter Thickness Conductivity System Type Delivery (Watts) (ft) (in) (in) (Btu/Hr-ft-F) -,------------------------------------ ------ HYDRONIC.1 1 Storage Combined FanCoil n/a 50 0.75 0.375 0.023 J HYDRONIC.2 2 Storage Combined FanCoil n/a 50 0.7-5 0..375 0.023 COMPUTER METHOD SUMMARY Page 5 C-2R ------------------------------------------------------------------------------- Project Title.......... Mediterra Bldg. III Date..01/27/04 14:12:07 ------------------------------------------------------------------------------= ------------------------------------------------------------------------------- MICROPAS6 v6.01 File-MEDIT_3• Wth-CTZ15S92 Program -FORM C-2R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- SPECIAL FEATURES AND MODELING`ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection.' *** This is a multiple orientation building.with no orientation restrictions. This printout is for the front facing North. This building incorporates 'a Combined Hydronic Space and Water Heating System. This building incorporates non-standard Duct Location. This building incorporates non-standard Water Heating System HERS,REQUIRED VERIFICATION -------------------------- *** Items in this section require field testing and/or *** ***-verification by a certified home energy rater under *** ***.the supervision of a CEC-approved HERS provider using *** *** CEC approved testing'and/or verification methods and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates non-standard Duct Location. REMARKS Building Type III-R La Quinta, California V CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Project Title.......... Mediterra Bldg. III-R Date..01/27/04 14:11:35 Project Address........ Mediterra Apartments ******* --------------------- La Quinta, California *v6.01* I I Documentation Author... Huey Cao ******* I. Building Permit # I TAD Engineering I I 4633 E. Bond Ave. I Plan Check / Date I Orange, CA 92869 I I 714-595-0375 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-MEDIT_3R Wth-CTZ15S92 Program -FORM CF-lR User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ----------------------------------------------- -------------------------------- I GENERAL INFORMATION ------------------- Conditioned Floor Area...... 12426 sf Building Type .............. Multifamily Construction Type .......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 13 Number of Stories.......... 2 Floor Construction Type.... Slab On Grade Glazing Percentage......... 13.7 % of floor area -Average U-factor:.-:-•A.-6==Btu/hr--sf-.F ..___......._._.._ __..__. Average Glazing SHGC....... 0.55 Average Ceiling Height..... 9 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type Type R-value R-value R-value U-factor Location/Comments ------------------------------ ------------------------ ------------------- Wall Wood R-13 R-0 R-13 0.088 NORTH, EAST, SOUTH WEST, NORTHEAST NORTHWEST GARAGE WALL --- -Roof -Wood-------R-=11----•-R--1-9----R_-3.0 0_._0.3.1_Atti.c..___ _._�____ Door -Metal R-0 R-n/a R-0 0.470 METAL DOOR Solid Wood S1abEdge None R-0 R-n/a F2=0.900 To Outside SlabEdge None R-0 R-n/a F2=0.550 TO GARAGE Floor Wood R-19 R-0 R-19 0.037 OVER GARAGE FENESTRATION ------------ Over- Area U- Interior Exterior hang/ Orientation (sf) Factor SHGC Shading Shading -------------- Fins ----- -------------------- ----- ------ -------------- ------- Window .Front (N) 342.0 0.600 0.550 Standard Standard None Window Front (N) 24.0 0.600 0.550 Standard Standard Yes Door Front (N) 100.0 0.600 0.550 Standard Standard Yes Door Front (N) 96.0 0.600 0.550 Standard Standard Yes t CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-lR Project Title.......... Mediterra Bldg. III-R Date..01/27/04 14:11:35 ------------------------------------------------------------------------------- MICROPAS6 v6.01 File-MEDIT_3R Wth-CTZ15S92 Program -FORM CF-1R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments -------------------------------------------- ----------------------------------- FENESTRATION ------------ Over- Area U- Interior Exterior hang/ Orientation (sf) Factor SHGC Shading Shading Fins -------------------- Window Left (E) ----- 219.0 ------ 0.600 ------ 0.550 --------------- Standard -------------- Standard ----- None Window Left (E) 48.0 0.600 0.550 Standard Standard Yes Door' Left (E) 80.0 0.600 0.550 Standard Standard Yes Door Left (E) 96.0 0.600 0.550 Standard Standard Yes Window Back (S) 341.0. 0.600 0.550 Standard Standard None Window Back (S) 48.0 0.600 0.550 Standard Standard Yes Window Right (W) 189.0 0.600 0.550 Standard Standard None Window Right (W) 24.0 0.600 0.550 Standard Standard Yes Door Right (W) 20.0 0.600 0.550 Standard Standard Yes Window Front (NE) 40.0 0.600 0.550 Standard Standard None Window Right (NW) 40.0 0.600 0.550 Standard Standard None SLAB SURFACES Area Slab Type (sf) Standard Slab 5469 HVAC SYSTEMS ------------ Refrigerant Tested . ACCA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat Type ------------ Efficiency ------------ Airflow Location ------------------ R-value ------- Leakage ------- D ------ Type ---------- Hydronic 0.745 AFUE n/a Conditioned R-4.2 No No Setback —AC -Sp]. t----- - 10:-00--SEER----No-----Conditioned.--R�4..-2—.No---. __ .___No._____S.etbac.k-_ WATER HEATING SYSTEMS --------------------- Number Tank External I in Energy Size Insulation Tank Type Heater Type Distribution Type System -------------- Factor (gal) ------ R-value ---------- ------------ HYDRONIC.1 --- -------- ------------------- Storage Gas Standard 8 0.62 40 R- n/a HYDRONIC.2 Storage Gas Standard 5 0.60 50 R- n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-lR Project Title.......... Mediterra Bldg. III-R Date..01/27/04 14:11:35 ------------------------------------------------------------------------------- I MICROPAS6 v6.01 File-MEDIT�3R Wth-CTZ15S92 Program -FORM CF-lR I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- WATER HEATING SYSTEMS DETAIL Standby Internal Tank Recovery Rated Loss Insulation Pilot System ------------ Efficiency ------------ Input ------------ Fraction ---------- R-value --------------- Light ------- HYDRONIC.1 Storage 0.76 40000 Btuh n/a R- n/a n/a HYDRONIC.2 Storage 0.76 40000 Btuh n/a R- n/a n/a HYDRONIC PIPING AND SPACE HEATING --------------------------------- Pump Pipe Pipe Insulation Insulation Hydronic Hydronic Energy Length Diameter Thickness Conductivity System Type Delivery (Watts) (ft) (in) (in) (Btu/Hr-ft-F) ------------------------------------- ----------------------------------- HYDRONIC.1 Storage Combined FanCoil n/a 50 0.75 0.375 0.023' --...._. _._.. ..HYDRONIC_.2 _..:.: _ ... ......... _ .r,.....--_._.._..... Storage Combined FanCoil n/a 50 0.75 0.375 0.023 SPECIAL FEATURES AND MODELING ASSUMPTIONS ---------'-------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *.** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Combined Hydronic Space and Water Heating System. This building incorporates non-standard Duct Location. This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates non-standard Duct Location. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Project Title.......... Mediterra Bldg. IV Date..01/27/04 14:10:41 Project Address........ Mediterra Apartments ******* --------------------- La Quinta, California *v6..01* I I Documentation Author... Huey Cao ******* I Building Permit # I TAD Engineering I i 4633 E..Bond Ave. I Plan Check / Date I Orange, CA 92869 714-595-0375 1 Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. I MICROPAS6 v6.01 File-MEDIT_4 Wth-CTZ15S92; Program -FORM CF-1R I I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area..... 10890 sf Building Type .............. Multifamily Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W' Number of Dwelling Units... 11 Number of Stories.......... 2 Floor Construction Type.... Slab On Grade Glazing Percentage......... 14.5 % of floor area Average Glazing U-factor... 0.6.Btu/hr-sf-F Average Glazing SHGC....... 0.55 Average Ceiling Height..... 9 ft BUILDING SHELL INSULATION Component Frame ------------------------- Cavity Sheathing, Total Assembly Type Type ------- R-value R-value -------- R-value U-factor -------------- Location/Comments ------------------------ ------------ Wall Wood -------- R-13 R-0 R-13 0,.088 NORTH, EAST, SOUTH WEST, NORTHEAST NORTHWEST GARAGE WALL -Roof- --Wood ....._R-.1.1 . R-1.9 R-3.0 _0 -0.31 .Atti.c Door Metal R-0 R-n/a R-0 0.470 METAL DOOR Solid Wood S1abEdge None R-0 R-n/a F2=0.900 To Outside. SlabEdge None R-0 R-n/a F2=0.550 TO GARAGE Floor Wood R-19 R-0 R-19 0.037 OVER GARAGE FENESTRATION ------------ Over- Area U- Interior Exterior hang/ Orientation (sf) Factor SHGC Shading Shading Fins -------------------- Window Front (N) ----- ------ --------------------- 342.0 0.600 0.550 Standard -------------- Standard ----- None Window. Front'(N) 24.0 0.600 0.550 Standard. Standard Yes Door Front (N) 100.0 0.600 0.550 Standard Standard Yes t� Door Front (N) 96.0 0.600 0.550 Standard Standard Yes CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-lR Project Title.......... Mediterra Bldg. IV Date..01/27/04 14:10:41 ------------------------------------------------------------------------------- MICROPAS6 v6.01 File-MEDIT_4 Wth-CTZ15S92 Program -FORM CF-lR User#-MP2350 User -TAD Engineering• Run-Mediterra Apartments ------------------------------------------------------------------------------- FENESTRATION Over - Area U- Interior Exterior hang/ Orientation (sf) Factor SHGC Shading Shading Fins -------------------- Window Left (E) ----- 258.0 ------ --------------------- 0.600 0.550 Standard -------------- Standard ----- None Window Left (E) 48.0 0.600 0.550 Standard Standard Yes Door Left (E) 20.0 0.600 0.550 Standard Standard Yes Window Back (S). 203.0 0.600 0.550-Standard Standard None Window Back (S) 48.0 0.60.0 0.550 Standard Standard Yes Window Right (W) 165.0 0.600 0.550 Standard Standard None Window Right (W) 24.0 0.600 0.550 Standard Standard Yes Door Right (W) 80.0 0.600 0.550 Standard Standard Yes Door. Right (W) 96.0 0.600 0.550 Standard Standard Yes Window Front (NE) 40.0 0.600 0.550 Standard Standard None Window Right (NW) 40.0 0.600 0.550 Standard Standard None SLAB SURFACES Area Slab Type (sf) Standard Slab 3933 HVAC SYSTEMS Refrigerant ------------ Tested ACCA , Equipment Minimum Charge and Duct Duct Duct Manual Thermostat Type Efficiency Airflow Location R-value Leakage . D Type Hydronic 0.745 AFUE n/a Conditioned R-4.2 No No Setback ACSplit- - 10.-00 SEER.. ..No .. Condi.ti.oned. ._R.4.2 No. No _S.etba.ck WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type, Heater Type Distribution Type System Factor (gal) R-value HYDRONIC.1 ' Storage Gas Standard 6 0.62 40 R- n/a HYDRONIC.2 Storag,e Gas Standard 5 0.60 50 R- n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF Project Title.......... Mediterra Bldg. IV Date..01/27/04 14:10:41 MICROPAS6 v6.01 File-MEDIT_4 Wth-CTZ15S92 Program -FORM CF-lR I I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- WATER HEATING ---------------------------- SYSTEMS DETAIL Standby Internal Tank Recovery Rated Loss Insulation Pilot System ------------ Efficiency ------------ Input ------------ Fraction ---------- R-value --------------- Light' ------- HYDRONIC.1 Storage 0.76 4000.0 Btuh n/a R- n/a n/a HYDRONIC.2 Storage 1 0.76 40000 Btuh n/a R- n/a n/a HYDRONIC PIPING AND SPACE HEATING Pump Pipe Pipe Insulation Insulation Hydronic Hydronic Energy Length Diameter Thickness Conductivity System ------------ Type -------- Delivery --------- (Watts) -------- (ft) ------ (in) ------- (in) ---------- (Btu/Hr-ft-F) ------------ HYDRONIC.1 Storage Combined FanCoil n/a 50 0.75 0.375 0.023 HYDRONIC.2 Storage Combined FanCoil n/a 50 0.75 0.375 0.023 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates.a Combined Hydronic Space and Water Heating System. This building incorporates non-standard Duct Location. This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-6R installation certificate. *** This building.incorporates non-standard.Duct:Location CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-1R Project Title.......... Mediterra Bldg. IV Date..01/27/04 14:10:41 I MICROPAS6 v6.01 File-MEDIT 4 Wth-CTZ15S92 Program-FORM.CF-lR I User4-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title =24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by'the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in' the Special Features Modeling Assumptions section. DESIGNER or OWNER DOCUMENTATION AUTHOR I Name.,— Name.... Huey Cao Company. Humphreys &Partners Company. TAD Engineering Address. 5350 Alpha Road Address. 4633 E. Bond Ave. Dallas, TX 75240 Orange, CA 92869 Phone... 972-701-9636 Phone... 714-595-0375 License. .`r—-Z•/`�Z� Signed.. Signed.. (date) (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone'... Signed.. '(date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF-1R Project Title.......... Mediterra Bldg. IV Date..01/27/04 14:10:41 Project Address........ Mediterra Apartments ******* --------------------- La Quinta, California *v6.01* 1_ 1 Documentation Author... Huey Cao ******* 1 Building Permit # I TAD Engineering I I 4633 E. Bond Ave. 1 Plan Check / Date 1 Orange, CA 92869 I I 714-595-0375 1 Field Check/ Date 1 Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. --- ------ --- - ---- --------------------------------------------- 1 MICROPAS6 v6.01 File-MEDIT_4 Wth-CTZ15S92 Program -FORM MF-lR 1 I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments 1 -----------------------------------------------------------------------------=- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance,requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for.the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- Design- Enforce- er ment *150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturer's labeled R-Value. *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors. 150(1): Slab edge insulation - water absorption rate no greater than 0.30, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. 116-17:_ F.ene.st.ration Produ.c.ts,_ Exteriox.Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets Commission quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal -or glass door MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF-lR ----------------------------------------=-------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Mediterra Bldg. IV Date..01/27/04 14:10:41 ------------------------------------------------------------------------------- I MICROPAS6 v6.01 File-MEDIT_4 Wth-CTZ15S92 Program -FORM MF-lR User#-MP2350 User -TAD Engineering Run-Mediterra Apartments I ------------------------------------------------------------------------------- b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES -------------------------------------------------------------- Design- Enforce- er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ✓' 150(i): Setback thermostat on all applicable heating and/or cooling systems. 150(j): Pipe and Tank insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water system. 5. Cooling system piping below 55 degrees insulated. 6. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and in- sulated,, to meet the requirements of the 1998 CMC sections 601, 603, and 604, and standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in-conditione.d__s.pa.c.e...Qpenings. shall ,be. ,sealed.. with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL1.81, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on -off switch, weatherproof operating instructions no electric MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 3 MF-1R Project Title.......... Mediterra Bldg. IV Date.'.01/27/04 14:10:41 MICROPAS6 v6.01 File-MEDIT_4 Wth-CTZ15S92 Program -FORM MF-lR User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------ ------------------------------------------ resistance heating and no pilot light. 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3-Pool system has directional inlets and a circulation pump time switch. ✓ 115: Gas -fired central furnaces, pool heaters, spa heaters or 'household cooking appliances have no continuously burning pilot light (Exception:.Non-electrical cooking appliances .with pilot < 150 Btu/hr). LIGHTING MEASURES ----------------- Design- Enforce- er ment 150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible. lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this requirement allowed in Sec. 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. ' COMPUTER METHOD SUMMARY Page l C-2fl -~--~~~-------==~--~� Pzoject Title........'. Mediterra Bldg' IV Dato.'01/27/04 I4:I0:4I ` Project'Address .. .� '. y@sditezra Apartments* °°°°°+° --------------------- ' La Ooiota, California +v6.01+ || Documentation Author .'. Huey Cao ~+++°++ | Building Permit # ] TAD Engineering | | 4633 E. Bond Ave. [ Plan Check / Date | Orange, CA 92869 | | 7I4-595-0375 | Field Check/ Date | Climate 3ooa........... 15 --------------------- Compliance Method ....'. MIC8DPAS6 v6.01 for 2001 Standards by Eoezoomp, Inc. | MICRDPAS6 v6'0I File-MEDIT_A wtb-CTCI5S92 Program -FORM C-2R | | Ooez#-MP2350 User -TAD Engineering Run-Mediterza Apartments | ------------------------------------------------------------------------------- MICROpAS8 ENERGY USE SUMMARY � Energy Use Standard Proposed Compliance ~ � (kBt6/af-yr) Design ---------- Design ---------- Margin � -_-------- � ~ ----------------------- � Space Heating .......... I.75 1.58 0`17 � � Space Cooliog.....'.... 34.60 31.73 2.87 � Water eeatiog.....''... . 21.39 17.9I -------- 3.*8 � -_-__--- � � ~ mortb Total -------- 57.74 51.22 6.52 � � / ~ Space Heating .......... 1.75 1.38 0.37 � Space CooIiug.....'.... 34.60 33.22 1.38 � � Water Heating .... ,..... 21.39 I7'91 -------- 3.48 � -------- ~ � ~ Eaat Total -------- 57.74 52'5I 5.23 ~ � ~ � Space Heating ...'...... ' 1.75 1.35 0.40 ~ Spaoe Cooliog.......... 34.60 32.97 `I.63 � ~ Water Heating .......... 2I'39 17.9I -------- 3.48 � -------- � � ~ Soutb Total -------- 57.74 52.23 5.51 � � Space Heating .......... 1.75 1.53 0.22 ~ = Space Cooling .......... 34.60 32.88 1.72 ~ = Water Heating .......... 21.39 17.91 -------- 3.48 � -------- � � � Weot Total -------- 57.74 52.32 5.42 � Building complies with Computer Performance COMPUTER METHOD SUMMARY Page 2 C-2R ----------------=-------------------------------------------------------------- ------------------------------------------------------------------------------- ... Mediterra Bld • Project Title....... g. IV Date..01/27/04 14:10:41 ------------------------------------------------------------------------------- MICROPAS6 v6.01 File-MEDIT_4 Wth-CTZ15S92 Program -FORM C-2R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area..... 10890 sf Building Type .............. Multifamily Construction Type New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 11 Number of Building Stories. 2 Weather Data Type.......... ReducedYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height...... Floor Area Zone Type (sf), -------------- ----- HOUSE Residence 10890 Slab On Grade 1 98010 cf 3933 sf 14.5 % of floor area 0.6 Btu/hr-sf-F 0.55 9 ft . BUILDING ZONE INFORMATION ------------------------- # of Vent Vent Air Volume Dwell Cond- Thermostat Height Area Leakage (cf) Units itioned Type (ft) (sf) Credit 98010 11.00 Yes Setback 8.0 Standard No OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) factor R-val Azm Tilt Gains Reference Comments HOUSE 1 Wall 1598 0.088 13 0 90 Yes W:13.2X4.16 NORTH 2 Wall 1207 0.088 13 90 90 Yes W.13.2X4.16 EAST 3 Wall 1231 0.088 13 180 90 Yes W.13.2X4.16 SOUTH 4 Wall 883 0.088 13 270 90 Yes W.13.2X4.16 WEST 5 Wall 68 0.088 13 45 90 Yes W.13.2X4.16 NORTHEAST 6 Wall 68 0.088 13 315 90 Yes W.13.2X4.16 NORTHWEST 7 Wall 962 0.088 13 0 90 No W.13.2X4.16 GARAGE WALL 8 Roof 6957 0.031 30 n/a 0 Yes R.30.2X4.24 Attic 9 Door 72 0.470 0` 0 90 Yes None METAL DOOR 10 Door 24 0.470 0 90 90 Yes None METAL DOOR 11 Door 120 0.470 0 180 90 Yes None METAL DOOR 12 Door 48 0.470 0 270 90 Yes None METAL DOOR 13 Door 100 0.470 0 0 90 No None Solid Wood 16 Floor 2755 0.037 19 n/a 0 No FC.19.2X8.16 OVER GARAGE COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... Mediterra Bldg. IV Date..01/27/04 14:10:41 I MICROPAS6 v6.01 File-MEDIT_4 Wth-CTZ15S92 Program -FORM C-2R i I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- HOUSE 14 S1abEdge - 310 0.900 R-0 No To Outside 15 S1abEdge 118 0.550 R-0 No TO GARAGE FENESTRATION SURFACES ------------------ 7-- Area U- Act Exterior Shade Interior Shade .Orientation (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC ---------------------- ----- ----- ----- --- ---- -------------- -------------- HOUSE 1 Window Front (N) 342.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 2 Window Front (N) 24.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 3 Door Front (N) 100.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 4 Door Front (N) 96.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 5 Window Left (E) 258.0 0.600 0:-550 90 90 Standard/0.76 Standard/0.68 6 Window Left (E) 48.0 0.600 0.550 90 90 Standard/0.76 Standard/0.68 7 Door Left (E) 20.0 0.600 0.550 90 90 Standard/0.76 Standard/0.68 8 Window Back (S) 203.0 0.600 0.55.0 180 90 Standard/0.76 Standard/0.68 9 Window Back (S) 48.0 0.600 0.550 180 90 Standard/0.76 Standard/0.68 10 Window Right (W) 165.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 11 Window Right (W) 24.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 12 Door Right (W) 80.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 13 Door Right (W) 96.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 14 Window Front (NE) 40.0 0.600 0.550 45 90 Standard/0.76 Standard/0.68 15 Window Right (NW) 40.0 0.600 0.550 315 90 Standard/0.76 Standard/0.68 OVERHANGS AND SIDE FINS ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght ----------- ----- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- HOUSE 2 Window 24.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 100.0 3.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 96.0 6.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 48.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 7 Door 20.0 3.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 48.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a, n/a n/a 11 Window 24.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 12 Door 80.0 3.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 13 Door 96.0 6.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... Mediterra Bldg. IV Date..01/27/04 14:10:41 -----------------------------=------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS6 v6.01 File-MEDIT_4 Wth-CTZ15S92. Program -FORM C-2R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- SLAB SURFACES ------------- Area Slab Type (sf) HOUSE ' Standard Slab 3933 HVAC SYSTEMS ------------ Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type Efficiency Airflow Location R-value Leakage D Eff -------------------------------------------------------------------- ---- HOUSE Hydronic 0.745 AFUE n/a Conditioned R-4.2 No No 1.000 ACSplit 10.00 SEER No Conditioned R-4.2 No No 1.000 WATER HEATING SYSTEMS --------------------- Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value ------------------------------------------ -------------- ---------------- HYDRONIC.1 1 Storage Gas Standard 6 0.62 40 R- n/a HYDRONIC.2 2 Storage Gas Standard 5 0.60 50 R- n/a WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss- Insulation Pilot System Efficiency Input Fraction R-value Light -------------------------------------------------------------------- HYDRONIC.1 1 Storage 0.76 40000 Btuh n/a R- V a n/a HYDRONIC.2 2'Storage 0.76 40000 Btuh n/a R- n/a n/a HYDRONIC PIPING AND SPACE HEATING --------------------------------- Pump Pipe Pipe Insulation Insulation Hydronic Hydronic Energy Length Diameter Thickness Conductivity System Type Delivery (Watts) (ft) (in) (in) (Btu/Hr-ft-F) -----------------------------=------- ---------------------=------------- HYDRONIC.1 1 Storage Combined FanCoiI n/a 50 0.75 0.375 0.023 HYDRONIC.2 2 Storage Combined FanCoil n/a 50 0.75 0.375 0.023 COMPUTER METHOD SUMMARY Page 5 C-2R ... Mediterra Bldg. Project Title........ g. IV" Date..01/27/04 14:10:41 MICROPAS6 v6.01 File-MEDIT_4 Wth-CTZ15S92 Program -FORM C-2R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments. ---------------------------------------------------------- --------------------- SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and ***. ***.verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Combined Hydronic Space and Water Heating System. This building incorporates non-standard Duct Location. This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION -------------------------- *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision"of a CEC-approved HERS provider using *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates non-standard Duct Location. REMARKS Building Type IV-R La Quinta, California CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- '``' Project Title.......... Mediterra Bldg. IV-R Date..01/27/04 14:09:49 Project Address........ Mediterra Apartments ******* --------------------- La Quinta, California *v6.01* I I .Documentation Author... Huey Cao ******* I Building Permit # I TAD Engineering I 1 4633 E. Bond Ave. I Plan•Check / Date I Orange, CA 92869 I 1 714-595-0375 1 Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- I MICROPAS6 v6.01 File-MEDIT_4R Wth-CTZ15S92 Program -FORM CF-lR 1 I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments w 1 ------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area..... 10890 sf Building.Type.............. Multifamily Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 11 Number of Stories........... 2 Floor Construction Type.... Slab On Grade Glazing Percentage......... 14.5 % of floor area Average Glazing U-factor... 0.6 Btu/hr-sf-F Average Glazing SHGC....... 0.55 Average Ceiling Height..... 9 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type Type ------- R-value -------- R-value ------ -- R-value ------- U-factor Location/Comments ------- ------------------------ ------------ Wall Wood R-13 R-0 R-13 0.088 NORTH, EAST, SOUTH WEST, NORTHEAST NORTHWEST GARAGE WALL -Roof -Wood- R--ll _ .R-.L9 _ _ _ R7,3.0 0.._0.31. Attic .... Door Metal R-0 R-n/a R-0 •0.470 METAL DOOR Solid Wood SlabEdge None R-0 R-n/a F2=0.900 To Outside SlabEdge None R-0 R-n/a F2'0.550 TO GARAGE Floor Wood R-19 R-0 R-19 0.037 OVER GARAGE FENESTRATION ------------ Over- Area U- Interior Exterior. hang/ Orientation (sf) Factor SHGC Shading Shading -------------- Fins ----- - -------------------- Window Front (N) ----- 342.0 ------ 0.600 ------ •0.550 --------------- Standard Standard None - Window Front (N) 24.0 0.600 0.550 Standard Standard Yes Door Front (N) 100.0 0.600 0.550 Standard Standard Yes Door Front (N) 96.0 0.600 0.550 Standard Standard _ Yes CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-lR ------------------------------------------------------------------------------- ... Mediterra Bldg. s Project Title....... g. IV-R Date..01/27/04 14:09:49 I MICROPAS6 v6.01 File- MEDIT_4R Wth-CTZ15S92 Program -FORM CF-1R I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments I ------------------------------------------------------------------------------- FENESTRATION ------------ Over- Area U- Interior Exterior hang/ Orientation (sf) Factor SHGC Shading Shading -------------- Fins -------------------- Window Left (E) ----- 177.0 ------ 0.600 ------ 0.550 --------------- Standard Standard ----- None Window Left (E) 24.0 0.600 0.550 Standard Standard Yes Door Left (E) 80.0 0.600 0.550 Standard Standard Yes Door Left (E) 96.0 0.600 0.550 Standard Standard Yes Window Back (S) 203.0 0.600 0.550 Standard Standard None Window Back (S) 48.0 0.600 0.550 Standard Standard Yes Window Right (W) 237.0 0.600 0.550 Standard Standard None window Right (W) 48.0 0.600 0.550 Standard Standard Yes Door Right (W) 20.0 0.600 0.550 Standard Standard Yes Window Front (NE) 40.0 0.600 0.550 Standard Standard None Window Right (NW) 40.0 0.600 0.550 Standard Standard None, SLAB SURFACES ------------- Area Slab Type (sf) Standard Slab 3933 HVAC SYSTEMS Refrigerant Tested ACCA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat Type Efficiency Airflow Location R-value Leakage D Type -------------------------------------------------------- ---------------- Hydronic 0.745 AFUE n/a Conditioned R-4.2 No No Setback -- AGSp-lit--- ----1-0:00--SEER No- Condi.t.ioned—_R=_4..2 -_No __ : _ ._.N.o_._-,_S.e.tba.c.k ._. WATER HEATING SYSTEMS Number Tank External in Energy .Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value HYDRONIC.1 Storage Gas Standard .6 0.62 40 R- n/a HYDRONIC.2 Storage Gas Standard 5 0.60 50 R- n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R -------------------- -f Project Title.......... Mediterra Bldg. IV-R Date..01/.27/04 14:09:49 I MICROPAS6 v6.-01 File-MEDIT_4R Wth-CTZ15S92 Program -FORM CF-1R I I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments I ------------------------------------------------------------------------------- •WATER HEATING SYSTEMS DETAIL ---------------------------- Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R-value Light -------------------------------------------------------------------- HYDRONIC.1• Storage 0.76 40000 Btuh n/a R- n/a n/a HYDRONIC.2 Storage 0.76 40000 Btuh• n/a R- n/a n/a HYDRONIC PIPING AND SPACE HEATING --------------------------------- Pump Pipe Pipe Insulation Insulation Hydronic Hydronic Energy Length Diameter Thickness Conductivity System Type Delivery (Watts) (ft) (in) (in) (Btu/Hr-ft-F) ------------------------------------- ----------------------------------- HYDRONIC.1 Storage Combined FanCoil n/a 50 0.75 0.375 0.023 HYDRONIC.2 Storage Combined FanCoil n/a 50 0.75 0.375 0.023 SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building With.no orientation restrictions. This printout is for the front facing North. This building incorporates a Combined Hydronic Space and Water Heating System. This building incorporates non-standard Duct Location. This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION *** Items in this sectiontrequire field testing .and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC atpproved testing and/or verification methods and *** *** must be reported on the CF-6R installation certificate. '*** This building incorporates non-standard Duct Location. f �. ' CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-I8 Pzojoot Title.......... Mediterza Bldg. IV-D Date..01/27/04 I4:09:49 | MZCROPAG6 n6.01 File-MEDZT 4R 'Wtb-CT3I5892 Program -FORM CF-IR | _ | Ooer#-MP2350 User -TAD Engineering Run-Mediterra Apartments | -----------_----------------------------------_--------_-_-------------------_- - REmARKS ------- ^ ` COMPLIANCE STATEMENT ----_--------------- zbis certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts I and 6' of the Calfforoia Code of Regulations, and the administrative regulations to . implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is. ' submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER DOCUMENTATION AUTHOR ' Name`... Name '... Huey Cao Company. Humphreys m Partners Company. rxu» Engineering Addze$a. 5350 Alpha Road Address. 4633 E. Bond Ave. ' Dallas, T% 75240 Orange, CA 92869 ' 'Pbooe... 972-701-9636 ' Pbooe'.. 7I4-595-0375 . License. Signed.. Signed.. (date) (date) ' -ENFORCEMENT AGENCY. , Name .... . Title... Agency.. ~. 2bnoe.'. ' Signed.. . (date) ' ` . .. ' ' ^ MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF-lR ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- t' Project Title.......... Mediterra Bldg. IV-R Date..01/27/04 14:09:49 Project Address........ Mediterra Apartments ******* --------------------- La Quinta, California *v6.01* I I Documentation Author... Huey Cao ******* I Building Permit # I TAD Engineering I I 4633 E. Bond Ave. I Plan Check / Date I Orange, CA 92869 I I 714-5.95-0375 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS6 v6.01 File-MEDIT_4R Wth-CTZ15S92 Program -FORM MF-lR I I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- Design- Enf.orce- er ment *150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturer's labeled R-Value. *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors. 150(1): Slab edge insulation - water -absorption rate no greater than 0.30, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified -or installed meets insulation quality standards. Indicate type and form. 11,6-.17_:--- Feneatration Products, ._Exterior _Doors and I_nf.iltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets Commission quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF-1R Project Title.......... Mediterra Bldg. IV-R Da.te..01/27/04 14:09:49 MICROPAS6 v6.01 File-MEDIT_4R Wth-CTZ15S92 Program -FORM MF-lR I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments --------------------------------------------------------------------=---------- b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. V SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM-MEASURES ----------------------=--------------------------------------- Design- Enforce- er ment 110-113: HVAC .equipment, water heaters, showerheads and faucets certified by the Commission. 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Setback thermostat on all applicable heating and/or cooling systems. 150(j): Pipe and Tank insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped -with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water system. 5. Cooling system piping below 55 degrees insulated. 6". Piping insulated between heating source and indirect hot water tank. ✓ *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and in- sulated, to meet the requirements of the 1998 CMC sections 601, 603, and 604, and standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely - - - - - in- conditioned space. -Openings- sha1-1- be sealed with mastic, tape, aerosol sealant, or other duct -closure system that,meets the applicable requirements of UL181, .UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on -off i'; switch, weatherproof operating instructions, no electric MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 3 MF-lR Project Title.......... Mediterra Bldg. IV-R Date..01/27/04 14:09:49 MICROPAS6 v6.01 File-MEDIT_4R Wth-CTZ15S92 Program -FORM MF-lR User#-MP2350 User -TAD Engineering Run-Mediterra Apartments resistance heating and no pilot light. 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr). LIGHTING MEASURES ----------------- Design- Enforce- er ment 150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general -lighting shall be controlled by a switch on a readily -accessible lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or•bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this requirement allowed in Sec. 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. S COMPUTER METHOD SUMMARY Page 1 C-2R ------------------------- Project Title.......... Mediterra Bldg. IV-R Date..01/27/04- 14:09:49 Project Address........ Mediterra Apartments ******* -------------.----=--- La Quinta, California *v6.01* I I Documentation Author... Huey Cao' ******* I Building Permit # I TAD.Engineering I I 4633 E. Bond Ave. I Plan Check / Date I Orange, CA 92869 I I 714-595-0375 I Field Check/ Date d Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.0.1 for 2001 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- I MICROPAS6 v6.01 File-MEDIT_4R Wth-CTZ15S92 Program -FORM C-2R I User#-MP2350 User -TAD Engineering Run-Mediterra Apartments -----=---------------------- ---------------------------- MICROPAS6 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) Design Design Margin = = Space Heating.......... 1.75 1.57 0.18 = = Space Cooling.......... 34.60' 31.66 2.94 = = Water Heating........... 21.39 17.91 3.48 = - _ = North -Total' - - - - - - - - 57.74 - - - - - - - - 51.14 - - - - - - - - b. 6.60 = = Space Heating.......... 1.75 . 1.37 0.38 = ' = Space Cooling.......... 34.60 32.95 1.65 = = Water Heating.......... 21.39 17.91 3.48 = = East Total 57.74 52.23 5.51 = = Space Heating.......... 1.75 1.36 0.39 = = Space Cooling.......... 34.60 32.86 1.74 = = Water Heating 21.39 17.91- .3.48 = = South Total 57.74 52.13 5.61 = = Space Heating ........... 1.75 1.54 0.21 = - Space Cooling.......... 34.60 33.03 1.57 = - Water Heating.......... 21.39 17.91 3.48 = West Total 57.74 52.48 5.26 *** Building complies with Computer Performance *** COMPUTER METHOD SUMMARY Page 2 C-2R -------------------- fF:: Project Title.. .... Mediterra Bldg. IV-R Date..01/27/04 14:09:.49 MICROPAS6 v6.01 File-MEDIT_4R Wth-CTZ15S92 Program -FORM C-2R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ---------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area..... 10890 sf Building Type .............. Multifamily Construction Type .......... New Building Front Orientation. Cardinal -. N,E,S,W Number of Dwelling Units... 11 Number of Building Stories. 2 Weather Data Type.......... ReducedYear Floor Construction Type.... Slab On Grade Number of Building Zones... 1 Conditioned Volume......... 98010 cf. Slab -On -Grade Area......... 3933 sf Glazing Percentage......... 14.5 % of floor area Average Glazing U-factor... 0.6 Btu/hr-sf-F Average Glazing SHGC....... 0.55 Average Ceiling Height..... 9 ft BUILDING ZONE INFORMATION y Floor # of Vent Vent Air .. Area Volume Dwell Cond- Thermostat Height Area Leakage Zone Type (sf) (cf) Units itioned ------- ------------ Type (ft) ----------- ----- -------- (sf) Credit --------- -------------- HOUSE ----- Residence 10890 98010 11.00 Yes Setback 8.0 Standard No OPAQUE SURFACES Area --------------- U- Insul Act Solar Form 3 Location/ Surface (sf) factor R-val Azm Tilt Gains Reference Comments HOUSE 1 Wall 1598 0.088 13 0 90 Yes W.13.2X4.16 NORTH 2 Wall 895 0.088 13 90 90 Yes W.13.2X4.16 EAST 3 Wall 1231 0.088 13 180 90 Yes W.13.2X4.16 SOUTH 4 Wall 1204 0.088 13 270 90 Yes W.13.2X4.16 WEST 5 Wall 68 0.088 13 45 90 Yes W..13.2X4.16 NORTHEAST 6 Wall 68 0.088 13 315 90 Yes W.13.2X4.16 NORTHWEST 7 Wall 962 0.088 13 0 90 No W.13.2X4.16 GARAGE.WALL 8 Roof 6957 0.031 30 n/a 0 Yes R.30.2X4.24 Attic 9 Door 72 0.470 0 0 90'Yes None METAL DOOR 10 Door 24 0.470 0 90 90 Yes None METAL DOOR 11 Door 120 0.470 0 180 90 Yes None METAL DOOR 12 Door 48 0.470 0 270 90 Yes 'None METAL DOOR 13 Door 100 0.470-0 0 90 No None Solid Wood 16 Floor 2755 0.037 19 n/a 0 No FC.19.2X8.16 OVER GARAGE COMPUTER METHOD SUMMARY Page 3 C-2R ------------------------------------------------------------------------------- #T"' Project Title.......... Mediterra Bldg. IV-R Date..01/27/04 14:09:49 MICROPAS6 v6.01 File-MEDIT_4R Wth-CTZ15S92 Program -FORM C-2R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- PERIMETER LOSSES ---------------- Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- HOUSE 14 SlabEdge 310 0.900 R-0 No To Outside 15 SlabEdge 118 0.550 R-0 No TO GARAGE FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade Orientation (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC ---------------------- ----- ----- ----- --- ---- -------------- -------------- HOUSE 1 Window Front (N) 342.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 2 Window Front (N) 24.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 3 Door Front (N) 100.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 4 Door Front (N) 96.0 0.600 0.550 0 90 Standard/0.76 Standard/0.68 5 Window Left (E) 177.0 0.600 0.550 90 90 Standard/0.76 Standard/0.68 6 Window Left (E) 24.0 0.600 0.550 90 90 Standard/0.76 Standard/0.68 7 Door Left (E) 80.0 0.600 0.55.0 90 90 Standard/0.76 Standard/0.68 8 Door Left (E) 96.0 0.600 0.550 90 90 Standard/0.76 Standard/0.68 9 Window Back (S) 203.0 0.600 0.550 180 90 Standard/0.76 Standard/0.68 10 Window Back (S) 48.0 0.600 0.550 180 90 Standard/0.76 Standard/0.68 11 Window Right (W) 237.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 12 Window Right (W) 48.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 13 Door Right (W) 20.0 0.600 0.550 270 90 Standard/0.76 Standard/0.68 14 Window Front (NE) 40.0 0.600 0.550 45 90 Standard/0.76 Standard/0.68 15 Window Right (NW) 40.0 0.600 0.550 315 90 Standard/0.76_ Standard/0.68 OVERHANGS AND SIDE FINS ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght ----------- ----- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- HOUSE 2 Window 24.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 100.0 3.00 8.00 5.00 1.00 n/a n/a• n/a n/a n/a n/a n/a n/a 4 Door 96.0 6.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 24.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 7 Door 80.0 3.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 8 Door 96.0 3.00 8.00 5.00 1.00 n/a n/a, n/a n/a n/a n/a n/a n/a 10 Window 48.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 48.0 6.00 4.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a 13 Door 20.0 3.00 8.00 5.00 1.00 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... Mediterra Bldg. IV-R Date-.01/27/04 14:09:49 MICROPAS6 v6.01 File-MEDIT_4R Wth-CTZ15S92 Program -FORM C-2R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ------------------------------------------------------------------------------- SLAB SURFACES ------------- Area Slab Type (sf) HOUSE Standard Slab 3933 HVAC SYSTEMS ------------ Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type ------------- Efficiency ----------- Airflow Location -------------------- R-value Leakage ------------------------ D Eff ---- HOUSE Hydronic 0.745 AFUE n/a Conditioned R-4.�2 No No 1.000 ACSplit 10.00 SEER No Conditioned R-4.2 No No 1.000 WATER HEATING SYSTEMS --------------------- Number Tank External _ in Energy Size Insulation Tank Type ------------ Heater Type ----------- Distribution Type ------------------- System- Factor (gal) -------------- ------ R-value ---------- HYDRONIC.1 1 Storage' Gas Standard 6 0.62 40 R- n/a HYDRONIC.2 2 Storage Gas Standard, 5 0.60 50 R- n/a WATER HEATING SYSTEMS DETAIL ----------------------=----- Standby Internal Tank - - - - - - -- - - Recovery- Rated _.._. _ - ., _.Loss.. I.ns.ula.tion . '_ ..Pi.lot _... System Efficiency Input Fraction R-value Light HYDRONIC.1 1 Storage 0.76 40000 Btuh_ n/a R- n/a n/a HYDRONIC.2 2 Storage 0.76 40000 Btuh n/a R- n/a n/a HYDRONIC PIPING AND SPACE HEATING --------------------------------- Pump Pipe Pipe Insulation Insulation Hydronic Hydronic Energy Length Diameter Thickness.Conductivity System Type Delivery (Watts) (ft) (in) (in) (Btu/Hr-ft-F) ----------------------------=-------- ----------------------------------- HYDRONIC.1 1 Storage Combined FanCoil n/a 50 0.75 0.375 0.023 ��. HYDRONIC.2 WE 2 Storage Combined FanCoil n/a 50 0.75 0.375 0.023 COMPUTER METHOD SUMMARY Page 5 C-2R Project Title.......... Mediterra Bldg. IV-R Date..01/27/04 14:09:49 MICROPAS6 v6.01 File-MEDIT_4R Wth-CTZ15S92 Program -FORM C-2R User#-MP2350 User -TAD Engineering Run-Mediterra Apartments ----------- -,------------------------------------------------------------------- SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Combined Hydronic Space and Water Heating System. This building incorporates non-standard Duct Location. This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION --------------------------- *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using• *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates non-standard Duct Location. REMARKS i TITLE 24 REPORT Title 24 Report for: Mediterra Clubhouse La Quinta, CA Project Designer: Humphreys & Partners 5350 Alpha Road Dallas, TX 75240 (972) 701-9636 Report Prepared By: Huey Cao TAD Engineering 4633 E. Bond Ave. • VQl.C. 2/16/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883 5900. EnergyPro 3_1_By EnergySoft _ __ _ Job Number: _ User Number: 5787 TABLE OF CONTENTS Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form ENV-MM Envelope Mandatory Measures Form MECH-MM Mechanical Mandatory Measures Job Number: User Number: 5787 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF-1 :PROJECT NAME DATE Mediterra Clubhouse _ _ 2/16/2004 PROJECT ADDRESS — _ La Quinta :PRINCIPAL DESIGNER - ENVELOPE — TELEPHONE Building Permit # _ Humphreys & Partners (972) 701-9636 DOCUMENTATION AUTHOR :TELEPHONE Checked by/Date TAD Engineering _ (714) 595-0375 —; Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA ;CLIMATE ZONE 3,625 Sq.Ft. 15 BUILDING TYPE X NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION x. NEW CONSTRUCTION _ ADDITION ALTERATION �__ EXISTING + ADDITION STATEMENT OF COMPLIANCE ;This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using the performance compliance approach. 'DOCUMENTATION AUTHOR :SIGNATURE ; DATA- _H uevCao...---...._.---- ,The Principal Designers hereby certify that the proposed building design represented in the construction documents and modelled ;for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this i ipermit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title !24, Part 6. ENV. LTG. MECH. I.. 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to — sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. - i 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section !'— - -- 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed j contractor preparing documents for work that I have contracted to perform. 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE _ Indicate location on plans of Note Block for Mandatory Measures i ':PRINCIPAL ENVELOPE DESIGNER -NAME Humohrevs & Partr Required Forms ENV-1 SIGNATURE DATE — Indicate location on plans of Note Block for Mandatory Measures 'Lighting Compliance Not In The Scope Of Required FormsTS—S�TblYlittal ;PRINCIPAL LIGHTING DESIGNER - NAME ! SIGNATURE LIC. NO. 'DATE Indicate location on plans of Note Block for Mandatory Measures 41,j i Z_ _ _--- Required Forms ;MECH-1. MECH-2, MECH-3 ;PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATU E ILIC. NO. DATE TAD Engineering___—... _ w�y, 3.1 By EnergySoft User Number: 5787 Job Number: 3of15 PERFORMANCE CERTIFICATE OF COMPLIANCE'' Part 2' of 3 ,. •PERF-1 r .. DATE. tJ Mediterra Clubhouse 2/1.6/2004.. . ' ANNUAL SOURCE -ENERGY USE SUMMARY kBtu/s ft- r ,.. - " Standard Proposed Compliance' s d ENERGY COMPONENT_ Design- y Design Margin fandardFy�T®fop°sed�a Space Heating 3.23 2.15. 1 08 [>" t� Space Cooling 69.27. _ 56.61 12 66 "f Ax fftl Indoor Fans 28.72 ' 35.34- — 6 62M. ; # �� Heat, Rejection 0.00 0.00; 0 00 f ' Pumps'& Misc. ;' 0 00 0 00 0 0ol i �r }�k Domestic Hot Water — o oo, 0.00, o oo Lighting ; + 34 43 34 43� 0.001 �R' - Receptacle, 16 72 16.720 00, f liars+0 x�r , 'Process 0 00. 0.0010 00j TOTALS: 152.36 �" 145.24 .7.12 , e, ui eiwyyrf' ' i - Percent better than Standard: - 4.7% (' 4.7% excluding process)' BUILDING COMPLIES GENERAL:INFORMATION Building Orientation _ _North o deg; Conditioned Floor Area i 3 625, sgft} .1 Number of Stories 1 Unconditioned Floor Area j O'sgft Number of Systems - 51 Conditioned Footprint Area r =o sgft. s ----- - Number of Zones _._ '8` :. I r Orientation Gross Area Glazing Area' Glazier Ratio . t` Front Elevation North)l I 635 sgft. t 156! sgft A 24.6%! I - --_�.� - Left•Elevation _ East)! I 715 sgft. t' .. 144 sgft. 20.1° _( Rear Elevation (South] "5151,sgn. .192i sgft. 37.3%; i - - Right -Elevation._ _ (west)— sgff '� -- 72!sgn.A� Total---2,515�sgft -- —• 5641sgft. 22.4% ` Roof . + : 3,6251 sgn. ! 0l sgft. .0.0%=- - -- -- — Standard _ Proposed •.LEEDTM Energy & Atmosphere Credit. r- — ," Lighting Power Density . _ 1.169 w/sgft. l 1:1'69;•w/sgft.A , , Savings vs. Title 24t r5:25% . Prescriptive Env. Heat Loss 645:13twn ��_ 5731Btu/h . „ Energy Performance Credit2 1 Points — —. 1 T v Prescriptive Env. Heat Gain _— 78,321'Btu/h-F` '' 68 226; Btu/h-F ti excludes process and reciptacle • 2. see LEED table 8-c or 8 d , Remarks: Run Initiation Time: 02/16/04'16:51:41 Run 'Code:. 1076979101 j EnergyPro 3.1 , ,: By Energysoft' User Number: 5787 . Job Number. ---- -- — --- --- s - . • x_ PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-1 PROJECT NAME DATE Mediterra Clubhouse 2/16/2004 __] ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft.) Inst. LPD (W/sf)1 Port. LPD (W/sf)1 Ctrl. Credits (W/sf)2 Tailored Proc. Loads (W/sf) LPD (W/sf) 3 LEASING LOBBY Business Center Comp Bldg Office 120 '1.200 Leasing & Offices Comp Bldg Office 320 '1.200 Leasing Lobby Comp Bldg Office 340 '1.200 OFFICES Leasing & Offices Comp Bldg Office 885 -1.200 EXERCISE ROOM Exercise Room Exercise Center 500 -1.000 Corridor & Restrooms Corridor/Restroom/Su ort 525 .0.600 CLUBROOM Club Room Convention/Conference 830 '1.500 Kitchen Kitchen & Food Prep 105 `1300 ] Notes: 1. See LTG-1 (items marked with asterisk, see LTG-2 by others) 2. See LTG-3 3. See LTG-4 Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. i Authorized Signature or Stamp EneravPro 3.1 By EnergySoft User Number: 5787 Job Number: Page:5 of 15 s ENVELOPE COMPLIANCE -SUMMARY. I Performance ENV-1 .. PROJECT NAME I -Mediterra Clubhouse 4.� DATE -2/16/2004 OPAQUE SURFACES # Surface Type Framing Type Area U-Fac. Act. Azm. Solar Gains Tilt Y/N Form 3 Reference Location / Comments 1 Roof Wood 120 0.035 151 0 X1 I R-30 Roof R.30.2x12.16 Business Center 2 Wall Wood 96 0.088 331 90 X I IR-13wall W.13.2x4.16 Business Center 3 lWall Wood 1 76 0.088 61 90 X I JR-13Wall W.13.2x4.16 Business Center 4 Roof Wood 140 0.035 151 0 X R-30 Roof R.30.2x12.16 Leasing & Offices 5 Wall Wood 40 0.088 331 90 X I R-13 Wall .13.2x4.16 Leasing & Offices 6 Roof Wood 180 0.035 151 0 X11 R-30 Roof R.30.2x12.16 Leasinq & Offices 7 Wall Wood 35 0.088 241 90 x1l R-13 Wall W.13.2x4.16 . Leasin & Offices " 8 Wall Wood 111 0.088 331 90 X11 R-13 Wall W.13.2x4.16 Leasing & Offices 9 Roof Wood 340 0.035 151 0 x1l R-30 Roof R.30.2x12.16 Leasing Lobby+ 10 IRoof Wood 240 0.035 151 0 x1l I R-30 Roof R.30.2x12.16 Leasing & Offices 11 Wall Wood 111 0.088 331 90 x1l JR-13Wall W.13.2x4.16 Leasing & Offices 12 Wall Wood 35 0.088 61 90 X11 JR-13Wall W.13.2x4.16 Leasing & Offices 13 Roof Wood 160 0.035 151 0 X11 I R-30 Roof R.30.2x12.16 Leasing & Offices 14 Roof Wood 135 0.035 151 0 x1l I R-30 Roof R.30.2x12.16 Leasing & Offices 15 Wall Wood 99 •0.088 241 90 X11 JR-13Wall W.13.2x4.16 Leasing & Offices 16 Wall Wood 86 0.088 331 90 X I JR-113Wall W.13.2x4.16 . Leasing & Offices 17 Roof Wood 60 _ 0.035 151 0 X R-30 Roof R.30.2x12.16 Leasing & Offices 18 Roof Wood 290 0.035 151 0 X R-30 Roof R.30.2x12.16 Leasing & Offices 19 Wall lWood 268 0.088 241 90 X JR-113Wall W.13.2x4.16 Leasing & Offices 20 Door INone 20 0.387 241 90 X Solid Wood Door Leasing & Offices FENESTRATION SURFACES uneCK DOX IT tswaing Is - iuu,uuu sgTi uT l.rti anu - iu,uuu syrt vciucdi yiduny uicn 11Fn1. %.cnuwduun w rcquucu. Site Assembled Glazing r u .., nicor �nn_ca or -Ait- -A ciihmi} MPPr-- I nhPI f.artificate Fnrm # Type Area U-Fac. Act. Azm.1 SHGC Glazing Type Location / Comments 1 Window 24 0.490 -331 0.40 Dual Panes windows Business Center 2 Window 24 0.490 61 0.40 Dual Panes windows Business Center 3 Window 12 0.490 331 0.40 Dual Panes windows Leasing & Offices 4 Window 48 0.490 331 0.40 Dual Panes windows Leasin .& Offices 5 Window 24 0.490 331 0.40 Dual Panes windows. -Leasing & Offices 6 Window 24 0.490 331 0.40 Dual Panes windows Leasin & Offices 7 Window 16 0.490 241 0.40 Dual Panes windows -Leasing & Offices 8 Window 24 0.490 331 0.40 Dual Panes windows Leasing & Offices 9 Window 16 0.490 241 0.40 Dual Panes windows -Leasing & Offices 10 Window 16 0.490 241 0.40 Dual Panes windows Leasing & Offices 11 Window 24 0.490 151 0.40 Dual Panes windows Exercise Room 12 Window 24 0.490 151 0.40 Dual Panes windows Exercise Room 13 Window 24 0.490 61 0.40 Dual Panes windows Exercise Room 14 Window 24 0.4901 61 0.40 Dual Panes windows Exercise Room 15 Window- --~,- - --- - --24- -0.490= --61 - -- - -0:40 - Dual Panes windows --- --Corridor & -Restrooms. EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 1 None 0.76 2 None 0.76 3 None 0.76 2.0 6.0 8.0 1.0 8.0 8.0 4 None 0.76 8.0 6.0 8.0 1.0 8.0 8.0 5 None 0.76 6.0 4.0 6.0 1.0 6.0 6.0 6 None 0.76 6.0 4.0 6.0 1.0 6.0 6.0 7 None 0.76 8 None 0.76- 9 None 0.76 10 None 0.76 11 None 0.76 12 None 0.76 13 None 0.76 14 None 0.76 15 None 0,76 +` • Run Initiation Time: 02/16/04 16:51:41 Run Code: 1076979101 EnergyPro 3.1 By EnergySoft User Number: 5787 Job Number: Page:6 of 15 c ENVELOPE COMPLIANCE SUMMARY Performance ENV-1 (PROJECT NAME DATE Mediterra Clubhouse 2/16/2004 OPAQUE SURFACES # Surface Type Framing Type Area U-Fac. Act. Azm. Solar Gains Tilt Y/N Form 3 Reference Location / Comments 21 Roof Wood 500 0.035 151 0 IX I I R-30 Roof R.30.2x12.16 Exercise Room 22 lWall Wood 107 0.088 1 151 90 X I IR-13Wall W.13.2x4.16 Exercise Room 23 Wall Wood 35 0.088 1 331 90 X I IR-13Wall W.13.2x4.16 Exercise Room 24 Wall Wood 182 0.088 61 90 x I IR-13Wall W.13.2x4.16 Exercise Room 25 Roof Wood 225 0.035 151 0x I I R-30 Roof R.30.2x12.16 Corridor & Restrooms 26 Wall Wood 222 0.088 61 90 X I IR-13Wall .13.2x4.16 Corridor & Restrooms 27 Roof Wood 150 0.035 151 0 x1l I R-30 Roof R.30.2x12.16 Corridor & Restrooms 28 Roof Wood 150 0.035 151 0 x1l I R-30 Roof R.30.2x12.16 Corridor & Restrooms 29 IRoof Wood 830 0.035 151 0 XII I R-30 Roof R.30.2x12.16 Club Room 30 Wall Wood 216 0.088 151 90 x1l IR-13Wall W.13.2x4.16 Club Room 31 Wall Wood 156 0.088 241 90 x1l IR-13Wall W.13.2x4.16 Club Room 32 Wall Wood 56 0.088 61 90 XII IR-13Wall (W.13.2x4.16) Club Room 33 Roof Wood 105 0.035 151 0 x1l I R-30 Roof R.30.2x12.16 Kitchen IH FENESTRATION SURFACES Site Assembled Glazing �j Check box it Building Is >= 1UU,000 sqtt of W-A ano >= iu,uuu sgtt verucal glazing men rvrra, t..enmcatnon is requireo. 9 I � Fnllnw NFRC 100-SR Prncadures and submit NFRC Label Certificate Form. # Type Area U-Fac. Act. Azm. SHGC Glazing Type Location / Comments 16 Window 24 0.490 61 0.40 Dual Panes windows orridor & Restrooms 17 Window 24 0.490 151 0.40 Dual Panes windows lub Room 18 Window 24 0.490 151 0.40 Dual Panes windows lub Room 19 Window 24 0.490 151 0.40 Dual Panes windows lub Room 20 Window 36 0.490 1 151 0.40 Dual Panes windows lub Room 21 Window 36 0.490 1 151 0.40 Dual Panes windows lub Room 22 Window 24 0.490 241 0.40 Dual Panes windows lub Room 23 Window 24 0.490 61 0.40 Dual Panes windows lub Room EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 16 None 0.76 8.0 3.0 6.0 1.0 6.0 6.0 17 None 0.76 18 None 0.76 19 None 0.76 20 None 0.76 21 None 0.76 22 None 0.76 23 None 0.76 Run Initiation Time: 02/16/04 16:51:41 Run Code: 1076979101 EnergyPro 3.1 By EnergySoft User Number: 5787 Job Number: Page:7 of 15 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Mediterra Clubhouse 1 2/16/2004 SYSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R-VALUE COOLING DUCT LOCATION R-VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE MECHANICAL SYSTEMS LEASING LOBBY OFFICES I I EXERCISE ROOM Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Outside Air Cert. Auto No Economizer 117 cfm Heat Pump 8.00 HSPF Split DX 12.0 SEER / 10.6 EER YORK HP042X1221 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Outside Air Cert. Auto No Economizer 133 cfm Heat Pump 8.00 HSPF Split DX 12.0 SEER / 10.7 EER YORK HP048X1221 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Require n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Outside Air Cert. Auto No Economizer 229 cfm Heat Pump 8.00 HSPF Split DX 12.0 SEER / 10.3 EER YORK HP06OX1221 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? Y: Yes N: NoVENTILATION TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch 0: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N: Natural A: Auto G: Gravity A: Air W: Water N: Not Required EC: Economizer Control See Section 144 e 3 Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE EnergvPro 3.1 By EnergySoft User Number: 5787 Job Number: Page:8 of 15 CERTIFICATE OF COMPLIANCE Performance MECM-1 PROJECT NAME IDATE Mediterra Clubhouse 1 2/16/2004 1 SYSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R-VALUE COOLING DUCT LOCATION R-VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE MECHANICAL SYSTEMS CLUBROOM Programmable Switch Heating & ooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Tern n/a Outside Air Cert. Auto No Economizer 514 cfm Heat Pump 8.00 HSPF Split DX 12.0 SEER / 10.7 EER YORK HP048X1221 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No CODE TABLES: Enter code from table below into columns above. C�L MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME DATE ' --'------' -----PUMPS' � '"^ Motorunve r ' . ' | ' ' ' | .� . . � . . � � � Energy^Standby Rated Vol. or Recovery Loss or Ext. | / m�/m. . Name �����/ ummouoon/ !' | �__-'--''_''___--_�'_-- _---_----�-___--__-_/ !Split DX V 42 ':Split DX 3 47 :Split DX 58 ICENTRAL SYSTEM FAN SUMMARY HEATING i COOLING r --- RETURN FAN | �--------------'--'�- ---� --''------------SUPPLYEAN Motor! Drive � / Moto,' o,weSystem ' |' Name Fa cation |/'"""H,"°"^'""' �CunstamVo|ume �blow-Through nooe� � i! �_-�'_----�__-_�� ' YomxHpn4nx1zzl ! i i � ' � ' 1 none; | ' !�-----�'---------'--'--- |L-�----'------�-----------------------� Constant Volume -------------�--�--�-----~-----�-'---� !'Blow -Through! ------r-''--r------�---i � none, /!�--------�------T�----------�---------� r----�---------�----�/ User Number: 5787 -------------------'---------- -. � Job Number: MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2I PROJECT NAME DATE Mediterra Clubhouse I 2/16/2004 in. CFM I1 EXHAUST FAN Room Name Qty. CFM I BHP Motor Eff. Drive Eff. TERMINAL FAN BASEBOARD Motor Drive CFM BHP Eff. Eff. Type Output EXHAUSTFAN Room Name Qty. CFM BHP Motor Eff. Drive Eff. EnerovPro 3.1 By EnerovSoft User Number: 5787 Job Number: Pagel 1 of 15 � MECHANICAL VENTILATION MECH-3 (PROJECT NAME DATE Mediterra Clubhouse 2/16/2004 MECHANICAL VENTILATION o a a a o o© a o a o AREA BASIS ZONE/SYSTEM COND. AREA (SF) CFM PER SF MIN. CFM (B x C) Business Center 120 0.15 18 Leasing & Offices 320 0.15 48 Leasing Lobby 340 0.15 51 LEASING LOBBY Leasing & Offices 885 0.15 133 OFFICES Exercise Room 500 0.15 75 Corridor & Restrooms 525 0.15 79 EXERCISE ROOM Club Room 830 0.50 415 Kitchen 105 0.15 16 CLUBROOM OCCUPANCY BASIS NO. CFM MIN. OF PER CFM PEOPLE PERSON (ExF) Total Total Total Total REQ'D O.A. (MAX OF D OR G) 18 48 51 117 133 133 75 79 154 415 16 431 VAV MIN. RATIO C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I.. Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H-J). I EnergvPro 3.1 By EnergySoft User Number: 5787 Job Number: Page:12 of 15 JENVELOPE MANDATORY MEASURES ENV-MM ;PROJECT NAME DATE Mediterra Clubhouse 2/16/2004 DESCRIPTION :Designer ;Enforcement i x' § 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply j with the California Quality Standards for insulating material; Title 20, Chapter 4, Article 3 X § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24,'Part 2. X § 117(a) All Exterior Joints and openings in the building that are observable sources of air - leakage shall be caulked, gasketed, weatherstripped or -otherwise sealed. X ; § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). X I, § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not i exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U-value according to NFRC procedures. i § 118(e) Demising Walls in Nonresidential Buildings: f — The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R-value of no less than R-11 between framing members. 1- -_ " . EnergyPro 3.1 By EnergySoft User Number: 5787 Job Number: Page:13 of 15 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME Mediterra Clubhouse DATE 2/16/2004 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies § 111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. § 115(a) Fan type central furnaces shall not have a pilot light. X] § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. X❑ § 124 Air handling duct systems shall be installed and insulated incompliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: a§ 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or § 122(e)1 B An occupancy sensor to control the operating period of the system; or § 122(e)1 C A 4-hour timer that can be manually operated to control the operating period of the system. X❑ § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. ❑ § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. © § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 3.1 By EnergySoft User Number: 5787 Job Number: Page:14 of 15 11 MECHANICAL (MANDATORY (MEASURES Part 2 of 2 IMECH-NIM PROJECT NAME iDATE Mediterra Clubhouse 2/16/2004 Description :Designer :Enforcement' 7. Ventilation )(; § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. _ § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. `X : § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as i shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the ! person with overall responsibility for the design of the ventilation system; or I i § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or � r -- remote device capable of measuring the quantity of outside air on a continuous j basis and displaying that quantity on a readily accessible display divice; or i § 121(f)4 Another method approved by the Commission. I� Service Water Heating Systems i § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. I Foot actuated control valves,.and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hM water to a maximum of 0.75 gallons per minute. Self -closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self -closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self -closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro 3.1 By EnergySoft User Number: 5787 Job Number: Page:15 of 15