PGA West - Monterra TR 32742 BTCP2017-0005 (Plans 1-4) 2016 Code Update - Revision 1Bin 1f . - _ ,
arty of La Quinta
Building &r Safety Division
Permit ; 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
19IMP 600E E uilding Permit Application and Tracking Sheet
Project Address: 5�j—O u umn alley Court . .10 Owner'sName1a Quihta Housing 1,LLC ,
A. P. Number: 767-860-037
Aadress:27271 Las RamblaS, Suite 100
Legal Description: Tract 32742
City, sT, zip:Mission Viejo, Ca 92691
Contractor: Woodbridge Pacific Group
Tel h n
ep o e: 949-445-4612
Address:27271 -Las Ramblas Suite 100
Project Description: Revision to approved 2016 Plans
city, ST, zip: Mission Viejo, CA •92691
�
Tele hone:949-445-4612
P
IS f
�l��2 Z �rJ ce �c G
PC
State Lic. # : 963887
City Lic. #..0112138
Arch., Engr., Designer: Heltec
Address:777 E. Tahquitz Canyon Way, Ste 200-50
S
City, ST, zip: Palm Springs, CA 92262
Telephone: - -
P 760 969 5033
<:>'
�a�?��
Construction Type: Occupancy:
State . i #� Lc 55606
Project type (circle one): New Add'n Alter Repair • Demo
Name of Contact Person: Bob Richards
Sq. Ft.:
#Stories:
#Units:
Telephone # of Contact Person: 949-445-4612
Estimated value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
M
Submittal
Req'd
Rcc'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Platt Check Deposit '
Truss Cates.
Called Contact Person
Plan Check Balance
Title 24 Cafes.
Plans picked up
Construction '
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2°" Review, ready for corrections/issue
Electrical
Subcontaclor List
Called Contact Person
Plumbing
Grant Aced
Plans picked up
S.114.I.
11.0-A. Approval
Plans resubmitted
Grading
IN ROUSE:-
Review, ready for correct!onsrssuc
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fecs,
Total fermi( Ices
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 11:13, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-17.ribd16x
CF1 R-PRF-01
Page 1 of 9
GENERAL INFORMATION
01
Project Name
Monterra Plan 1
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.2.1 (695)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.1
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
3180
15
Number of Zones
1
16
Slab Area (ft2)
3180
17
Number of Stories
1
18
Addition Cond. Floor Area
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ft2),
n/a
21
Glazing Percentage (%)
16.7%
COMPLIANCE RESULTS
01
BuildingComplies with Computer Performance
P P s:s
02
This building incorporates features that require field testing;and/or venficahon;by a c6- hed HERS rater;under the supervision of a CEC-approved HERS provider.
. v
03
This building incorporates one or more Special Features shown below'-
This compliance analysis invalid only for permit applications through.October 24; 2017
?MVISION 41
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATER Z1 IF
lfi�7BY
Registration Number: 217-P010127994H-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:42:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:14:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
,. Project Name: Monterra Plan 1 Calculation Date/Time: 11:13, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-17.ribdl6x
CF1 R-PRF-01
Page 2 of 9
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDVI t2-yr)
Design
Design
Margin
Improvement
Space Heating
1.44
1.24
0.20
13.9%
Space Cooling
79.37
69.52
9.85
12.4%
IAQ Ventilation
0.89
0.89
0.00
0.0%
Water Heating
4.13
7.27
-3.14
-76.0%
PV Credit
----
0.00
0.00
----
North Facing Compliance Total
85.83
78.92
6.91
8.1%
Space Heating
1.44
1.82
-0.38
-26.4%
Space Cooling
79.37
74.86
4.51
5.7%
IAQ Ventilation
0.89
0.89
0.00
0.0%
Water Heating
4.13
7.27
-3.14
-76.0%
PV Credit
?
----
0.00
0.00
----
East Facing Compliance Total
85.83
84.84
0.99
1.2%
Space Heating
1.44
2.34
-0.90
-62.5%
Space Cooling
"
79 37
#�.`
1.67 19
IN
t
12.18
15.3%
IAQ Ventilation
{� 089
E
0.00
0.0%
Water Heating
1P�q
4.13y�
7:27
-3.14
-76.0%
PV Credit
'
H
�`--- R
R
0 00
0.00
---
South Facing Compliance Total
85.83
77.69
8.14
9.5%
Space Heating
a
. 1.44
1.67
-0.23
-16.0%
Space Cooling
79.37
71.52
7.85
9.9%
IAQ Ventilation
0.89
0.89
0.00
0.0%
Water Heating
4.13
7.27
-3.14
-76.0%
PV Credit
----
0.00
0.00
----
West Facing Compliance Total
85.83
81.35
4.48
5.2%
Registration Number: 217-P010127994H-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:42:14 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:14:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 11:13, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-17.ribd16x
CF1 R-PRF-01
Page 3 of 9
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV
Final EDR of Proposed Design
North
49.5
46.5
0.0
46.5
East
49.5
49A
0.0
49.1
South
49.5
45.9
0.0
45.9
West
49.5
47.5
0.0
47.5
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in pclimate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
photovoltaic (PV) renewable energy generation sufficient,to achieve a Final Energy Design Rating (EDR) ofzero,or Iess.,The PV System must be verified.
REQUIRED SPECIAL FEATURES. ' f ''' }'(
The following are features that must be installed as conditii4for meetmgithe`modeled energy performance,forahis computer analysis.
• Non-standard roof reflectance
• Insulation below roof deck
• Window overhangs and/or fins
• Pipe insulation, all lines
Registration Number: 217-P010127994H-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:42:14 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:14:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Monterra Plan 1 Calculation Date/Time: 11:13, Tue, Aug 22, 2017 Page 4 of 9
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-17.ribd16x
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
--None --
BUILDING - FEATURES INFORMATION
01
" . 02 :
03., .,
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling,
Umts
Number of Bedrooms
Number of Zones,r.,
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Monterra Plan 1
3180 1'
r'1F ' "t. %'i"
a
3
1'C
j 1 r t
0
1
ZONE INFORMATION x ` A - -*
01
02
03
04
05 '
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Plan 1
Conditioned
HVAC 1 & 21
3180
8
DHW Sys 1
-71
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door Area (ft2)
Tilt (deg)
N Wall
Plan 1
R-21 Wall (W.19.2x6.16)
0
Front
740
189.564
90
E Wall
Plan 1
R-21 Wall (W.19.2x6.16)
90
Left
880
64
90
S Wall
Plan 1
R-21 Wall (W.19.2x6.16)
180
Back
740
228
90
W Wall
Plan 1
R-21 Wall (W.19.2x6.16)
270
Right
880
72
90
R-38 Roof
Plan 1
R-38 Roof(R.38.204.16)
3180
Registration Number: 217-Po10127994H-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:42:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:14:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 11:13, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-17.ribdl6x
CFI R-PRF-01
Page 5 of 9
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Plan 1
Attic RoofPlan 1
Ventilated
4.36764
0.19
0.92
No
No
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
Window 1
Window
N Wall (Front-0)
1.5
8.0
1
12.0
0.32
0.23
Insect Screen (default)
Window 2
Window
N Wall (Front-0)
3.3
8.0
0.985
26.0
0.32
0.23
Insect Screen (default)
Window 3
Window
N Wall (Front-0)
1.5
8.0
1
12.0
0.32
0.23
Insect Screen (default)
Window 4
Window
N Wall (Front-0)
15.0
8.0
0.983
118.0
0-32
0.23
Insect Screen (default)
Window 5
Window.
E Wall (Left-90)
----
----
1
20.0
0.32
0.23
Insect Screen (default)
Window 6
Window
E Wall (Leff-g6)
----
----
1
20.0
0.32
0.23
Insect Screen (default)
Window 7
Window
E 1Nall,(Left 90)�� j
�' #�
-- -
1,
24.0
0.32
0.23
Insect Screen (default)
Window 8
Window
S Wall�$48.0
0.32
0.23
Insect Screen (default)
Window 9
A
Window
-180)
ry S Wall'(Back-1
~1
w6 0
0.32
0.23
Insect Screen (default)
Window 10
Window
°' y S`Wall (Back 1t30) ; �'
'`q--- J
V ----
11^
'y36.0
0.32
0.23
Insect Screen (default)
Window 11
Window
S Wall (Back-180)
----
1
6.0
0.32
0.23
Insect Screen (default)
Window 12
Window
S Wall (Back-180)
----
----
1
36.0
0.32
0.23
Insect Screen (default)
Window 13
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.23
Insect Screen (default)
Window 14
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.23
Insect Screen (default)
Window 15
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.23
Insect Screen (default)
Window 16
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.23
Insect Screen (default)
Window 17
Window
W Wall (Right-270)
----
I ----
1
52.0
0.32
0.23
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door
N Wall
21.6
0.50
Registration Number: 217-P010127994H-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:42:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-07312017-695 Report Generated at: 2017-08-22 11:14:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
'Project Name: Monterra Plan 1 Calculation Date/Time: 11:13, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-17.ribd16x
CF1R-PRF-01
Page 6 of 9
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
1 14
Overhang
Left Fin
Right
Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
Window 1
10
0.1
10
10
0
0
0
0
0
0
0
0
0
Window 2
10
0.1
10
10
0
0
0
0
0
0
0
0
0
Window 3
10
0.1
10
10
0
0
0
1 0
0
0
1 0
0
0
Window 4
10
0.1
10
10
0
0
0
1 0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
• Under Roof Joists: R-0.0 insul.
"
Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofPlan 1
Attic Roofs
Wood Framed Ceiling
? in. O C ^ ; "r'
= R 131
0.078
Roofing: Light Roof (Asphalt Shingle)
Ceilings below
,
t�
f x f`
V
Inside Finish: Gypsum Board
Cavity/Frame: R-9.1 /2x4
R-38 Roof(R.38.2x14.16)
attic)
t Wood Framed Ceiling
2x4 @ 16 in. O C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
`' j
.,t '+►� +*
f *
Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall (W.19.2x6.16)
I Exterior Walls
I Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
Plan 1
3180
224
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (011)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
--
Registration Number: 217-P010127994H-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:42:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:14:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 11:13, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-17.ribdl6x
CF1 R-PRF-01
Page 7 of 9
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1 (1)
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
Tank
Energy
Tank Insulation
Tank Location or
Heater
Number
Volume
Factor or
Input
R-value
Standby Loss /
Ambient
Name
Element Type
Tank Type
of Units
(gal)
Efficiency
Rating/Pilot
(Int/Ext)
Recovery Eff
NEEA Heat Pump Type
Condition
DHW Heater 1
Gas
Small Storage
1
75
0.58 EF
65,000 Btu/hr
R-0
n/a
n/a
/n
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC 1 & 21
Other Heating and Cooling
Systems
Heating Component 1
# # :: s ,,.
Cooling Component 1
� 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES ? ai
01'
: =� a m> _ 02" : {:; ,' e:
ck i r 03 .
04
Name
` �; iF
System Type �"`� r,�, � t �
' F
r Numberof Units
Efficiency
Heating Component 1
CntrlFurnace
2
80 AFUE
HVAC -COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Name
System Type
Number of Units
Efficiency
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
2
12.2
14.5
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Registration Number: 217-P010127994H-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:42:14 HERS Provider: CalCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:14:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
'Project Name: Monterra Plan 1 Calculation Date/Time: 11:13, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-17.ribdl6x
CF1 R-PRF-01
Page 8 of 9
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required tj
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 ;x ('
�" g�M.,02 J' � 4 �� � � � } �
03
Name s ?
�' wTVdeified Fan Watt Dr ;' ';
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
"*' i� _°+ �" Required:..', 1 a..
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
62
0.25
Default
0
Required
Registration Number: 217-P010127994H-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:42:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:14:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
'Project Name: Monterra Plan 1 Calculation Date/Time: 11:13, Tue, Aug 22, 2017
CF1 R-PRF-01
Page 9 of 9
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-17.ribdl6x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2017-08-22 11:42:14
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations. _ t'
3. The building design features or system design features identified orrthis Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submittedto;the enforcement agency for approval,with this building permit application.
Responsible Designer Name:
esp Ronsible Designer Signature
Tim Scott
n r�
Company:, .
Date Signed:
*'1 V R
Scott Design and Title 24, Inc.
2017-08-22 11 42:14
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
Ell`,rs0
Easy to Verify
at CaICERTS.com
Registration Number: 217-P010127994H-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:42:14
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-08-22 11:14:49
CF,RTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
'Project Name: Monterra Plan 2 Calculation Date/Time: 11:18, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 2-17.ribdl6x
CF1 R-PRF-01
Page 1 of 9
GENERAL INFORMATION
01
Project Name
Monterra Plan 2
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.2.1 (695)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.1
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
3220
15
Number of Zones
1
16
Slab Area (ft2)
3220
17
Number of Stories
1
18
Addition Cond. Floor Aiea
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ft)
n/a
21
Glazing Percentage (%)
19.8%
COMPLIANCE RESULTS , •..
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or venficahon by a certified HERS r&runder the supervision of a CEC-approved HERS provider.
03
This building incorporates one or moSpecial Feature!o s s wn below re 11'1-o 4"M la 0a s §a C
This co _: nce analysis is valid only for permit -applications thrtF ough,Octbber 241-2017
fcl�is)oN
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DAT02/10j 7 BY
f3T0j---77-017- 000-6
Registration Number: 217-P010128005F-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:44:08 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:18:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 11:18, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-17.ribdl6x
CFI R-PRF-01
Page 2 of 9
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.47
1.93
-0.46
-31.3%
Space Cooling
83.66
71.70
11.96
14.3%
IAQ Ventilation
0.89
0.89
0.00
0.0%
Water Heating
4.08
7.18
-3.10
-76.0%
PV Credit
----
0.00
0.00
--
North Facing Compliance Total
90.10
81.70
8.40
9.3%
Space Heating
1.47
1.82
-0.35
-23.8%
Space Cooling
83.66
78.59
5.07
6.1%
IAQ Ventilation
0.89
0.89
0.00
0.0%
Water Heating
4.08
7.18
-3.10
-76.0%
PV Credit
----
0.00
0.00
----
East Facing Compliance Total
90.10
88.48
1.62
1.8%
Space Heating
1.47
1.66
-0.19
-12.9%
Space Cooling
Z .86
°
11.80
14.1%
IAQ Ventilation
1r
0 89 # t ;
}
0'89
i
)ez _
t
,O
0.00
0.0%
Water Heating-Sx
4.08
7:18
-3.10
-76.0%
PV Credit
:7
�5
`�
'mac 0:00
0.00
.
----
1
.:
South Facing Compliance Total
90.10
81.59
8.51
9.4%
Space Heating
1.47
1.76
-0.29
-19.7%
Space Cooling
83.66
77.86
5.80
6.9%
IAQ Ventilation
0.89
0.89
0.00
0.0%
Water Heating
4.08
7.18
-3.10
-76.0%
PV Credit
----
0.00
0.00
----
West Facing Compliance Total
90.10
87.69
2.41
2.7%
Registration Number: 217-P010128005F-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:44:08 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:18:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 11:18, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-17.ribdl6x
CF1 R-PRF-01
Page 3 of 9
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV
Final EDR of Proposed Design
North
50.6
46.9
0.0
46.9
East
50.6
49.9
0.0
49.9
South
50.6
46.9
0.0
46.9
West
50.6
49.5
0.0
49.5
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in, climate. zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
l
photovoltaic (PV) renewable energy generation sufficient to achieve`a Final Energy Design'Ratng (EDR) ofizero,or Iess.,,The PV System must be verified.
i * :: REQUIRED SPECIAL FEATURES " f. , fit
The following are features that must be installed as condition for meeting the modeled energy performance for;this computer analysis. .
• Non-standard roof reflectance %M -
• Insulation below roof deck
• Window overhangs and/or fins
• Pipe insulation, all lines
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
-- None --
Registration Number: 217-P010128005F-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:44:08 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:18:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 11:18, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 2-17.ribdl6x
CF1 R-PRF-01
Page 4 of 9
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Monterra Plan 2
3220
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Plan 2
Conditioned
HVAC 1 & 21
3220
9
DHW Sys 1
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door Area (ft)
Tilt (deg)
N Wall
Plan 2
..,—R-21 Wall (W.19.2x6.16)
0
Front
740
217.6
90
E Wall
�,- _ Plan 2 `,
R21 Wall .(W:19 2x6 1,1i)�
Left
880
69
90
S Wall
Plan 2 '
= R 21 Wall (W,19 2x6 16j
180
r1 .Back �f�`
r'. .
740
292
90
W Wall
Plan 2a '
R 21=Wall (W 19 2xli':16)
2270 ,
� 'Right
J1 880
80
90
R-38 Roof
an 2 r,
- R=38 Roof(R.38 2x14.16)
«y,
ir-,
3220
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
I
Cool Roof
Attic Plan 2
Attic RoofPlan 2
Ventilated
4.36764
0.19
0.92
No
No
Registration Number: 217-Po10128005F-000-000-0000000-0000 Registration Datelfime: 2017-08-22 11:44:08 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:18:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 11:18, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-17.ribdl6x
CFI R-PRF-01
Page 5 of 9
FENESTRATION I GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
2X4.5 F
Window
N Wall (Front-0)
----
----
1
9.0
0.32
0.24
Insect Screen (default)
1.5X8 F
Window
N Wall (Front-0)
1.5
8.0
1
12.0
0.32
0.24
Insect Screen (default)
3.5X8 FD
Window
N Wall (Front-0)
3.5
8.0
1
28.0
0.32
0.24
Insect Screen (default)
1.5X8 F 2
Window
N Wall (Front-0)
----
----
1
12.0
0.32
0.24
Insect Screen (default)
2.5X6F
Window
N Wall (Front-0)
----
----
1
45.0
0.32
0.24
Insect Screen (default)
2.5X6F 2
Window
N Wall (Front-0)
----
----
1
45.0
0.32
0.24
Insect Screen (default)
2.5X6F 3
Window
N Wall (Front-0)
----
----
1
45.0
0.32
0.24.
Insect Screen (default)
2X5 F
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 2
Window;
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X4 SH
Window,
E Wall (Left-90)
----
----
1
8.0
0.32
0.24
Insect Screen (default)
3X5.5 SH
Window
E Wall (Left-90)
----
----
1
16.5
0.32
0.24
Insect Screen (default)
6X5.5 SH
Window
EWall (Left'90)q"� `
Tf
'`d` ' ''
'i 1
16.5
0.32
0.24
Insect Screen default
2X4 SH 2
Window
i E Wall Left 90 ; i
8.0
0.32
0.24
Insect Screen default
6X8 FD
Window
""`S Waif Back'180
���� ( )
f ---=
'`- 'r
1
-48.0
0.32
0.24
Insect Screen default
(default)
20X8 Pd
Window
S-Wall Back 180 *n
20.0
48 0.
1-
�160.0
0.32
0.24
Insect Screen default
6X8 FD 2
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
6X6 SL
Window
S Wall (Back-180)
----
----
1
36.0
0.32
0.24
Insect Screen (default)
2X5 F 3
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 4
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
6X6 SL 2
Window
W Wall (Right-270)
----
----
1
36.0
0.32
0.24
Insect Screen (default)
3X8 FD
Window
W Wall (Right-270)
----
----
1
24.0
0.32
0.24
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft)
U-factor
Door
N Wall
21.6
0.50
Registration Number: 217-P010128005F-000-000-0000000-0000 Registration Datelfime: 2017-08-22 11:44:08 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:18:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
.Project Name: Monterra Plan 2 Calculation Date/Time: 11:18, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-17.ribdl6x
CFI R-PRF-01
Page 6 of 9
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Distl-
Bot Up
Depth
Top Up
Dist R
Bot Up
1.5X8 F
10
0.1
10
10
0
0
0
0
0
0
0
0
0
3.5X8 FD
10
0.1
10
10
0
0
0
0
0
0
0
0
0
20X8 Pd
14
0.1
14
14
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type •
Construction Type
Framing
R-value
U-value
Assembly Layers
• Under Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofPlan 2
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Ceilings (below
Xa
rx
Cavity/Frame: R-9.1 /2x4
R-38 Roof(R.38.2x14.16)
attic)
Wood Framed Ceiling)
( , 2x4 @ 16 in O C i
1
�;} R 38
0.025
Over Ceiling Joists: R-28.9 insul.
Inside Finish: Gypsum Board
! r
fir.
k.. ,+. ;•,S
2x6 O.C.
'
R
K
Cavity/Frame: R-21 /2x6
R-21 Wall (W.19.2x6.16)
Exterior Walls
Wood Framed Wall'
@ 16 in.
21
0.069
Exterior Finish: 3 Coat Stucco
SLAB FLOORS
01
02
103
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R•value & Depth
Carpeted Fraction
Heated
Slab
Plan 2
3220
231
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
---
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1 (1)
1
.0%
Registration Number: 217-P010128005F-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:44:08 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:18:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 11:18, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-17.ribd16x
CF1 R-PRF-01
Page 7 of 9
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
Tank
Energy
Tank Insulation
Tank Location or
Heater
Number
Volume
Factor or
Input
R-value
Standby Loss /
Ambient
Name
Element Type
Tank Type
of Units
(gal)
Efficiency
Rating/Pilot
(IntlExt)
Recovery Eff
NEEA Heat Pump Type
Condition
DHW Heater 1
Gas
Small Storage
1
75
0.58 EF
1 65,000 Btu/hr
R-0
n/a
/n
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC 1 & 21
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1,�aCntrlFurnace:�
2
80 AFUE
HVAC - COOLING UNIT TYPES
Ol
02'� '>s
r �: 03 , '. i
`, 04 aR
05
. 06 & ems. E,;
07
08
"t
"F Efficiency V
i_.j i
Name
System Type
Number of Units
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
2
12.2
14.5
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
1-hers-dist
Registration Number: 217-P010128005F-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:44:08 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:18:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 11:18, Tue, Aug 22, 2017
CFI R-PRF-01
Page 8 of 9
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-17.ribdl6x
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
---
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02 k
" t e , 03 ...
.. I 04r'" t' '
05
06
Dwelling Unit
IAQ CFM-IAQ
r r1 R
Ji
Watts/CFM 'k
r
IAQ Fan Type°
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
62 s`
0 253'
0
Required
Registration Number: 217-P010128005F-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:44:08 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:18:52
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
• Project Name: Monterra Plan 2 Calculation Date/Time: 11:18, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-17.ribd16x
CFI R-PRF-01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2017-08-22 11:44:08
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submittedtothe enforcement agency for approval with this. building permit application.
Responsible Designer Name: ' 1 "t tU'
�a -t d
Reiponsifble Designer Signature
t
Tim Scott
i
"'� ;�a.
Compan y -�
Date Signed:„ .
Scott Design and Title 24, Inc.
2017-08-22 11:44:08'
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
0� ,. ❑'
Easy to Verify
at CaICERTS.com
Registration Number: 217-P010128005F-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:44:08
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-07312017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-08-22 11:18:52
CF,RTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 11:27, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-17.ribdl6x
CF1 R-PRF-01
Page 1 of 10
GENERAL INFORMATION
01
Project Name
Monterra Plan 3
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.2.1 (695)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.1
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ftZ)
3370
15
Number of Zones
1
16
Slab Area (ftZ)
3370
17
Number of Stories
1
18
Addition Cond. Floor Area
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ft)
n/a
21
Glazing Percentage (%)
20.7%
COMPLIANCE RESULTS -
01
Building Complies with Computer Performance"`�� ,
02
This building incorporates features that require field testing;,and/or verification by a certified HERS rater; under ttie supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features sFiown below *-` t «' Y>( .fig '
This compliance analysis is'valid.only for permit applications through October 24, 2017
REVISION «
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROi/E®
FOR CONSTRUCTION
DATE / 1 *1 % ,
OT -G P2017 - 0005
Registration Number: 217-P010128012G-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:46:00 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-67312017-695 Report Generated at: 2017-08-22 11:28:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
,i Project Name: Monterra Plan 3 Calculation Date/Time: 11:27, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-17.ribdl6x
CF1R-PRF-01
Page 2 of 10
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.78
1.45
0.33
18.5%
Space Cooling
85.39
75.82
9.57
11.2%
IAQ Ventilation
0.87
0.87
0.00
0.0%
Water Heating
3.90
6.86
-2.96
-75.9%
PV Credit
----
0.00
0.00
----
North Facing Compliance Total
91.94
85.00
6.94
7.5%
Space Heating
1.78
1.69
0.09
5.1%
Space Cooling
85.39
82.43
2.96
3.5%
IAQ Ventilation
0.87
0.87
0.00
0.0%
Water Heating
3.90
6.86
-2.96
-75.9%
PV Credit
----
0.00
0.00
----
East Facing Compliance Total
91.94
91.85
0.09
0.1%
Space Heating
1.78
2.79
-1.01
-56.7%
Space Cooling
85 39�
5
t c
X78.45
6.94
8.1%
IAQ Ventilation
0 87 .;t
g
,i'r.
0.87,
'
;
0.00
0.0%
Heating
6:8v6Water
2.96
75.9/
PV Credit
-- R0:00
0.00
South Facing Compliance Total
91.94
88.97
2.97
3.2%
Space Heating
1.78
2.23
-0.45
-25.3%
Space Cooling
85.39
73.59
11.80
13.8%
IAQ Ventilation
0.87
0.87
0.00
0.0%
Water Heating
3.90
6.86
-2.96
-75.9%
PV Credit
----
0.00
0.00
----
West Facing Compliance Total
91.94
83.55
8.39
9.1%
Registration Number: 217-P010128012G-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:46:00 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:28:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 11:27, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 3-17.ribdl6x
CFI R-PRF-01
Page 3 of 10
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV
Final EDR of Proposed Design
North
50.6
47.7
0.0
47.7
East
50.6
50.6
0.0
50.6
South
50.6
49.4
0.0
49.4
West
50.6
47.0
0.0
47.0
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
photovoltaic (PV) renewable energy generation sufficient to achieve a Final' Energy Design Rating (EDR) of zero or less. -The PV System must be verified.
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting1he..modeled energy performance forfthis computer analysis. t._. -,„
• Non-standard roof reflectance
• Insulation below roof deck
• Window overhangs and/or fins
• Pipe insulation, all lines
Registration Number: 217-P010128012G-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:46:00 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:28:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name: Monterra Plan 3 Calculation Date/Time: 11:27, Tue, Aug 22, 2017 Page 4 of 10
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 3-17.ribdl6x
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
• --None --
BUILDING - FEATURES INFORMATION
01
02 ,.
03.
04
05
06
07
Project Name
Conditioned Floor Area (ft2),
Number of Dwelling t
Units
,�.
<Number of Bedrooms
,� t'
Number of Zo.nes.-
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Monterra Plan 3
3370`;
' gfik
F, z3}
g 1f ,;
0
1
ZONE INFORMATION i;, .:p€, r7l,
01
02
F03
04
05'
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Plan 3
Conditioned
HVAC 1 & 21
3370
9
DHW Sys 1
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft)
Tilt (deg)
N Wall
Plan 3
R-21 Wall (W.19.2x6.16)
0
Front
720
91.6
90
E Wall
Plan 3
R-21 Wall (W.19.2x6.16)
90
Left
1061
192.5
90
S Wall
Plan 3
R-21 Wall (W.19.2x6.16)
180
Back
727
356.064
90
W Wall
Plan 3
R-21 Wall (W.19.2x6.16)
270
Right
1030
78
90
R-38 Roof
Plan 3
R-38 Roof(R.38.204.16)
3370
Registration Number: 217-P010128012G-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:46:00 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:28:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 11:27, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 3-17.ribdl6x
CFI R-PRF-01
Page 5 of 10
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Plan 3
Attic RoofPlan 3
Ventilated
4.36764
0.19
0.92
No
No
"a
,#6e"r
..r+�
En R
Registration Number: 217-P010128012G-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:46:00 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:28:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 11:27, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-17.ribdl6x
CFI R-PRF-01
Page 6 of 10
FENESTRATION I GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
1.5X8 F
Window
N Wall (Front-0)
2.0
8.0
0.75
12.0
0.32
0.24
Insect Screen (default)
3.6X8 FD
Window
N Wall (Front-0)
3.5
8.0
1
28.0
0.32
0.24
Insect Screen (default)
1.5X8 F 2
Window
N Wall (Front-0)
2.0
8.0
0.75
12.0
0.32
0.24
Insect Screen (default)
3X6 SH
Window
N Wall (Front-0)
----
----
1
18.0
0.32
0.24
Insect Screen (default)
2X5 F
Window
E Wall (Left-90)
----
--
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 2
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5.5 SH
Window
E Wall (Left-90)
----
----
1
11.0
0.32
0.24
Insect Screen (default)
5X5.5 F
Window
E Wall (Left-90)
----
----
1
27.5
0.32
0.24
Insect Screen (default)
2X5.5 SH 2
Window
E Wall (Lek-90)
----
----
1
11.0
0.32
0.24
Insect Screen (default)
2X5 F 3
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
10X8 PD
Window
E Wall (Left-90)
----
----
1
80.0
0.32
0.24
Insect Screen (default)
5X5 C
Window
E VNall (Left90) x �.
-A
1
25.0
0.32
0.24
Insect Screen (default)
2X4 C
Window
e?r. E Wall- Left 90 :'"
'' ";
---
d: t�1 t
8.0
0.32
0.24-
Insect Screen (default)
6X6 SL
Window
,a�.;::r S Walf (Back'-180)��
� ---=s
' �''
- �1 �`
•36:0
0.32
0.24
Insect Screen (default)
6X8 FD
Window
; S Wall (Backr180) f
19.Q
8.0
0 31.6'
� 48.0
0.32
0.24
Insect Screen (default)
16X8 PD
Window
S Wall (Back-180)
----
----
1
128.0
0.32
0.24
Insect Screen (default)
5X6 SL
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
5X6 SL 2
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
6X8 FD 2
Window
S Wall (Back-180)
19.0
8.0
0.316
48.0
0.32
0.24
Insect Screen (default)
2X5 F 4
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 5
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X4 SH
Window
W Wall (Right-270)
----
----
1
8.0
0.32
0.24
Insect Screen (default)
5X4 SL
Window
W Wall (Right-270)
----
1
20.0
0.32
0.24
Insect Screen (default)
2X6 SH
Window
W Wall (Right-270)
----
----
1
6.0
0.32
0.24
Insect Screen (default)
6X8 FD 3
Window
W Wall (Right-270)
----
----
1
24.0
0.32
0.24
Insect Screen (default)
Registration Number: 217-P010128012G-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:46:00 HERS Provider: CACERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:28:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:27, Tue, Aug 22, 2017
Input File Name: Monterra-Plan 3-17.ribdl6x
CF1 R-PRF-01
Page 7 of 10
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft)
U-factor
Door
N Wall
21.6
0.50
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right
Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
1.5X8 F
10
0.1
10
10
0
0
0
0
0
0
0
0
0
3:6X8 FD
10
0.1
10
10
0
0
0
0
0
0
0
0
0
1.5X8F2
10
0.1
10
10
0
0
0
0
0
0
0
0
0
6X8 FD
14
0.1
14
14
0
0
0
0
0
0
0
0
0
6X8 FD 2
14
0.1
14
14
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
rli 03
3;; 104'ti t
05
t 06
07
<
Total Cavity;
mterDesign
Construction Name
Surface Type
Construction Type
,� „-. Framing a- ,.
R-value,,
U-value
Assembly Layers
Under Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofPlan 3
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof(R.38.2xl4.16)
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall (W.19.2x6.16)
I Exterior Walls
IWood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
Plan 3
521
61
None
0.8
No
Hard Surface Slab
Plan 3
2849
280
None
0.8
No
Registration Number: 217-P010128012G-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:46:00 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:28:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
• Project Name: Monterra Plan 3 Calculation Date/Time: 11:27, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-17.ribdl6x
CFI R-PRF-01
Page 8 of 10
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
---
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1 (1)
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
Tank
Energy
Tank Insulation
Tank Location or
Heater
Number
Volume
Factor or
Input
R-value
Standby Loss /
Ambient
Name
Element Type
Tank Type
of Units
(gal)
Efficiency
Rating/Pilot
(Int/Ext)
Recovery Eff
NEEA Heat Pump Type
Condition
DHW Heater 1
Gas
Small Storage
1
- 75
0.58 EF
65,000 Btu/hr
R-0
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS tr I i 1.� S;o
01.5�.i,
02':..
afl«034 x !
r* 04
05
06
SC Sys Name
Type
Heating Unit Name
$ C,00ling Unit Name,.,
Fan Name
Distribution Name
HVAC 1 & 21
Other Heating and Cooling
System
Heating Component 1
V r 1-..e
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFurnace
2
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Name
System Type
Number of Units
Efficiency
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
I
2
I
1 12.2
14.5
F1-hers-cool
Not Zonal
Single Speed
Cooling Component
Registration Number: 217-P010128012G-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:46:00 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:28:31
CgRTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 11:27, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-17.ribd16x
CFI R-PRF-01
Page 9 of 10
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
HVAC -FAN SYSTEMS
01
102'�4
c 03
04
Name
()« Type
Fan Power(Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan -
0.57
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.57
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
64
0.25
Default
0
Required 771
Registration Number: 217-P010128012G-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:46:00 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:28:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
UProject Name: Monterra Plan 3 Calculation Date/Time: 11:27, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 3-17.ribdl6x
CF1 R-PRF-01
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2017-08-22 11:46:00
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to -the enforcement agency for approval;.with- this .building permit application.
Responsible Designer Name: $ +
Responsible Designer Signature T
Tim Scott '�t� '`
.�
Company: w-r s
i-
Date Signed:
t +� 4
Scott Design and Title 24, Inc.
2017-08-22 11:46:00
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
OrArTryO
1
Easy to Verify
at CaICERTS.com
Registration Number: 217-P010128012G-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:46:00
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-08-22 11:28:31
GERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 11:33, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 4-17.ribd16x
CF1 R-PRF-01
Page 1 of 9
GENERAL INFORMATION
01
Project Name
Monterra Plan 4
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.2.1 (695)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.1
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
3650
15
Number of Zones
1
16
Slab Area (ft2)
3650
17
Number of Stories
1
18
Addition Cond. Floor Area
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ft2)
n/a
21
Glazing Percentage (%)
19.0%
COMPLIANCE RESULTS `
01
Building Complies with Computer Performance *`t`',!
k.t
02
This building incorporates features that require field testing and/or verrficatioh a certified HERS rafer�under the supervision4of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown
This compliance analysis is valid -only for permit applications through.Octolier 24; 2017
Re-visoloN ok I
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DA
IF
del 6,6
Registration Number: 217-P010128020E-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:47:50
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-07312017-695
�To-o,,,
SEP 0 8 2016
CITY OF LA OUINTA
COMMUNITY DEVELOPMENT
J< %$*
HERS Provider:
Cal �
Report Generated at: 2017-08-22 11:
GERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
�t Project Name: Monterra Plan 4 Calculation Date/Time: 11:33, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-17.ribdl6x
CF1 R-PRF-01
Page 2 of 9
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.47
1.36
0.11
7.5%
Space Cooling
79.33
68.08
11.25
14.2%
IAQ Ventilation
0.84
0.84
0.00
0.0%
Water Heating
3.60
6.33
-2.73
-75.8%
PV Credit
----
0.00
0.00
-
North Facing Compliance Total
85.24
76.61
8.63
10.1%
Space Heating
1.47
1.77
-0.30
-20.4%
Space Cooling
79.33
75.39
3.94
5.0%
IAQ Ventilation
0.84
0.84
0.00
0.0%
Water Heating
,;;
3.60
6.33
-2.73
-75.8%
PV Credit
----
0.00
0.00
----
East Facing Compliance, Total
85.24
84.33
0.91
1.1%
Space Heating
1.47
1.73
-0.26
-17.7%
1_
z �#
W
°
Space Cooling
IAQ Ventilation
79 33
��
( 84
;
��
a {6644
t` � 0 84
C
12.89
0.00
16.2/0
°
0.0 /oWater
�'O
Heating
3
3'.60"�
`'" � �.
.4'6:33
-2.73
-75.8%
PV Credit
a-
Esc
Oi007
0.00
aw
South Facing Compliance Total
85.24
75.34
9.90
11.6%
Space Heating
1.47
1.54
-0.07
Space Cooling
79.33
74.23
5.10
6.4%
IAQ Ventilation
0.84
0.84
0.00
0.0%
Water Heating
3.60
6.33
-2.73
-75.8%
PV Credit
----
0.00
0.00
West Facing Compliance Total
85.24
82.94
2.30
2.7%
Registration Number: 217-P01012802OF-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:47:50 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-07312017-695 Report Generated at: 2017-08-22 11:34:10
GERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CFI R-PRF-01
Project Name: Monterra Plan 4
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:33, Tue, Aug 22, 2017
Input File Name: Monterra-Plan 4-17.ribdl6x
Page 3 of 9
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV
Final EDR of Proposed Design
North
49.6
45.7
0.0
45.7
East
49.6
49.2
0.0
49.2
South
49.6 +
45.2
0.0
45.2
West
49.6
48.6
0.0
48.6
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation require_ ment for Single Family, in. climate, zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
a
photovoltaic PV renewable energy generation sufficient,to achieve'a Final Energy"
Desi` n'i2atiiig`(EDR) of zero or less., The PV System must be verified.
P ( ) 9Y 9. n:.u� 9Y 9,,,
REQUIRED SPECIAL FEATURES �?, ;I 1I AUl
The following are features that must be installed as conddion;ifor meeting�the modeled energy performance. for., this computer analysis. - r,-I
• Non-standard roof reflectance
• Insulation below roof deck
• Window overhangs and/or fins
• Pipe insulation, all lines
Registration Number: 217-P010128020E-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:47:50 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-07312017-695 Report Generated at: 2017-08-22 11:34:10
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 11:33, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 4-17.ribd16x
HERS FEATURE SUMMARY
CF1 R-PRF-01
Page 4 of 9
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
--None --
BUILDING - FEATURES INFORMATION '
01
02 '
_ 03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)r
Number of Dwelling
-p Units:
w ..
Number of Bedrooms
Number of Zones,F,
Number of Ventilation
; Cooling Systems
Number of Water
Heating Systems
Monterra Plan 4
3650 1
1
j3 (
' 1
0
1
ZONE INFORMATION _ . _ € .. ` r" i 1 •I%
01
02
03
04
06— y
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Plan 4
Conditioned
HVAC 1, 2 & 31
3650
9
DHW Sys 1
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door Area (ft2)
Tilt (deg)
N Wall
Plan 4
R-21 Wall (W.19.2x6.16)
0
Front
860
244.019
90
E Wall
Plan 4
R-21 Wall (W.19.2x6.16)
90
Left
730
73
90
S Wall
Plan 4
R-21 Wall (W.19.2x6.16)
180
Back
860
282.5
90
W Wall
Plan 4
R-21 Wall (W.19.2x6.16)
270
Right
750
117.5
90
R-38 Roof
Plan 4
R-38 Roof(R.38.20.4.16)
3650
Registration Number: 217-P010128020E-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:47:50 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:34:10
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 11:33, Tue, Aug 22, 2017
CF1 R-PRF-01
Page 5 of 9
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-17.ribdl6x
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Plan 4
Attic RoofPlan 4
Ventilated
4.36764
0.19
0.92
No
No
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
1.5X8 F
Window
N Wall (Front-0)
1.3
8.0
1.154
12.0
0.32
0.24
Insect Screen (default)
3.5X8 FD
Window
N Wall (Front-0)
3.5
8.0
1
28.0
0.32
0.24
Insect Screen (default)
1.5X8 F 2
Window
N Wall (Front-0)
1.3
8.0
1.154
12.0
0.32
0.24
Insect Screen (default)
16X8 PD
Window
N Wall (Front-0)
18.0
8.0
0.889
128.0
0.32
0.24
Insect Screen (default)
8X8 PD
Window
N Wall (Front-0)
----
----
1
64.0
0.32
0.24
Insect Screen (default)
2X5 SH
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 SH 2
Window
�E Wall (Left 90) :"
} ''
f ;- -Ig
110.0
0.32
0.24
Insect Screen (default)
3X5.5 SH
Window
al E Wall; Left 90 ;
yr, (a _ ),, ;�"" �;
-
:"� �.
=- -'�
;�
°
j, 1 �:� �
16.5
0.32
0.24
Insect Screen (default)
3X5.5 SH 2
Window
,` < . ''� E Wall'(L"'eft=90)'""-� V � =- '
- -" `
-- "
41 li
` 1'6"5
0.32
0.24
Insect Screen (default)
2X5 F
Window
E 1Nall'(Left: 6) ;`
--- 3
,� ,r
'
1
"' 10.0
0.32
0.24
Insect Screen default
(default)
2X5 F 2
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
6X8 FD
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
5X4.5 SL
Window
S Wall (Back-180)
----
----
1
22.5
0.32
0.24
Insect Screen (default)
16X8 PD 2
Window
S Wall (Back-180)
16.0
8.0
1
128.0
0.32
0.24
Insect Screen (default)
6X8 FD 2
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
6X6 SL
Window
S Wall (Back-180)
----
----
1
36.0
0.32
0.24
Insect Screen (default)
2X5 F 3
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 4
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5.5SH
Window
W Wall (Right-270)
----
----
1
11.0
0.32
0.24
Insect Screen (default)
5X5.5 F
Window
W Wall (Right-270)
----
----
1
27.5
0.32
0.24
Insect Screen (default)
2X5.5 SH
Window
W Wall (Right-270)
----
----
1
11.0
0.32
0.24
Insect Screen (default)
3X8 FD
Window
W Wall (Right-270)
---
---
1
24.0
0.32
0.24
It Screen (default)
Registration Number: 217-P01012802oF-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:47:50 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:34:10
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 11:33, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-17.ribdl6x
CF1 R-PRF-01
Page 6 of 9
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft)
U-factor
Door
W Wall
24.0
0.50
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right
Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
1.5X8 F
10
0.1
10
10
0
0
0
0
0
0
0
0
0
3.5X8 FD
10
0.1
10
10
0
0
0
0
0
0
0
0
0
1.5X8F2
10
0.1
10
10
0
0
0
0
0
0
0
0
0
16X8 PD
4
0.1
4
4
0
0
0
0
0
0
0
0
0
16X8 PD 2 T
4.
0.1
4
4
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
g.t
04 { § '`{
05 t: r tr'
16
07
� 4 .a
��Totia Cavity
:,Winter Design
Construction Name
Surface Type
Construction Type.-
Framing ,
'R-value
U value
Assembly Layers
• Under Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofPlan 4
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof(R.38.2xl4.16)
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall (W.19.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ftZ)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
Plan 4
430
52
None
0.8
No
Hard Surface Slab
Plan 4
3220
263
None
0.8
No
Registration Number: 217-P010128020E-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:47:50 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:34:10
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 11:33, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-17.ribd16x
CFI R-PRF-01
Page 7 of 9
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
---
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1 (1)
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
Tank
Energy
Tank Insulation
Tank Location or
Heater
Number
Volume
Factor or
Input
R-value
Standby Loss I
Ambient
Name
Element Type
Tank Type
of Units
(gal)
Efficiency
Rating/Pilot
(Int/Ext)
Recovery Eff
NEEA Heat Pump Type
Condition
DHW Heater 1
Gas
Small Storage
1
75 :
0.58 EF
1 65,000 Btu/hr
R-0
n/a
/n
n/a
SPACE CONDITIONING SYSTEMS`
01
O2. `"
1 03 q t
'.4 0.4
05
06
SC Sys Name
� System Type
Heating Unit Name
q Cooling:Unit Name r 4
Fan Name
Distribution Name
HVAC 1, 2 & 31
Other Heating andCooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFurnace
3
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Name
System Type
Number of Units
Efficiency
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
3
12.2
14.5
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Registration Number:. 217-P01012802QF-000-000-0000000-0000 Registration DatefTime: 2017-08-22 11:47:50 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:34:10
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:33, Tue, Aug 22, 2017
Input File Name: Monterra-Plan 4-17.ribd16x
CF1 R-PRF-01
Page 8 of 9
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
HVAC -FAN SYSTEMS+ F
01
; ' tic � A 02 ti�~ "s 3 #
. ' 03
04
Name
+' r T e
Fan Power Watts/CFM
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
67
0.25
Default
0
Required
Registration Number: 217-P010128020E-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:47:50 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-22 11:34:10 .
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 11:33, Tue, Aug 22, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-17.ribd16x
CF1 R-PRF-01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2017-08-22 11:47:50
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip: f
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design'features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submittedlto the enforcement agency,for approval with this building permit application.
Responsible Designer Name:' $yam
�
Responsible Designer Signature '-
Tim Scott
T y
i wSco&
+
x, -. Y
,. t - ,~ .�
Company: $
Date; Signed:
Scott Design and Title 24, Inc.
2017-08 22 11 47:50'
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Easy to Verify
at CaICERTS.com
Registration Number: 217-Po1012802oF-000-000-0000000-0000 Registration Date/Time: 2017-08-22 11:47:50
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-08-22 11:34:10