PGA West - Monterra TR 32742 BTCP2017-0005 (Plans 1-4) 2016 Code Update - Title 24CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:40, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 4-17.ribdl6x
CF1 R-PRF-01
Page 1 of 9
GENERAL INFORMATION
01
Project Name
Monterra Plan 4
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.2.1 (695)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.1
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
3650
15
Number of Zones
1
16
Slab Area (f 2)
3650
17
Number of Stories
1
18
Addition Cond. Floor Area
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area'.(ft2)
.n/a
21
Glazing Percentage (%)
19.0%
COMPLIANCE RESULTSmR
01
Building Complies with Computer Performance OV-11
02
�.... h ". mb.."e` . � -- �c�. N� � J�,
This building incorporates features tha4 require field testing and/o v ification�by a eetttfi d H.ERS rater under the su#pergvisYon of a CEC-approved HERS provider.
03
This building incorporates one` -or moreSpecial Features°sho"wn below ..
H E R S R V I
ER
870:�-P701 -7 --cov5
CITY OF LA QUANTA
BUILDING & SAFETY DEPT,
APPROVE®
FOR CONSTRUCTION
DATE$ a BY
egistration Number: 217-P010128020E-000-000-0000000-0000
Building Energy Efficiency Standards - 2016 Residential Compliance
12L-AIV 9 --
M
OF -Fite
rccyisuduon udiei i nna• 2017-06-28 17:23:50
Report Version - CF1 R-05232017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-28 16:43:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:40, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis .
Input File Name: Monterra-Plan 4-17.ribdl6x
CFI R-PRF-01
Page 2 of 9
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.47
1.33
0.14
9.5%
Space Cooling
79.33
67.57
11.76
14.8%
IAQ Ventilation
0.84
0.84
0.00
0.0%
Water Heating
3.60
6.33
-2.73
-75.8%
PV Credit
----
0.00
0.00
----
North Facing Compliance Total
85.24
76.07
9.17
10.8%
Space Heating
1.47
1.73
-0.26
-17.7%
Space Cooling
79.33
74.90
4.43
5.6%
IAQ Ventilation
0.84
0.84
0.00
0.0%
Water Heating
3.60
6.33
-2.73
-75.8%
PV Credit
`t
0.00
0.00
East Facing Compliance Total
0 .,- . 85.24
83.80
1.44
1.7%
Space Heating
1.47
1.69
0.22
15.0%
.Space Cooling
r
79 33. t �w 55.83
0
Ali
13.50
17.0%
IAQ Ventilation r "
84
CLPV
084
y
0.00
0.0%
Water Heating
?
?. v3�tl) '
6 33 ft
-2.73
-75.8%
Credit
_a - R"'
0,00
E
R
0.00
S
»mod
South Facing Compliance Total
85.24
74.69
10.55
12.4%
Space Heating
1.47
1.51
-0.04
-2.7%
Space Cooling
79.33
73.73
5.60
7.1%
IAQ Ventilation
0.84
0.84
0.00
0.0%
Water Heating
3.60
6.33
-2.73
-75.8%
PV Credit
----
0.00
0.00
----
West Facing Compliance Total
85.24
82.41
2.83
3.3%
Registration Number: 217-P010128020E-000-000-0000000-0000 Registration Date/Time: 2017-06-28 17:23:50 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-28 16:43:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:40, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 4-17.ribd16x
CFI R-PRF-01
Page 3 of 9
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC). A score of zero represents the energy performance of a building
that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6
(such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under
Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building'Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so, that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV
Final EDR of Proposed Design
North
49.6
45.5
0.0
45.5
East
49.6
49.0
0.0
49.0
South
49.6 f
44.9
0.0
44.9
West
49.6 f'=j.
48.4
0.0
48.4
❑
Design meets Tier 1 requirementof`iI % or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30,%o�oregreateucode compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designate n requireme"r Single Family. in.climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
photovoltaic (PV) renewable',energy generation sufficient to�aclieye a Final Energy Design Rating (EDR) of zero less. -The PV System must be verified.
REQUIRED SPECIAL FEATURES < f.
The following are features that must be installed as condiUonfor meet ng themodested energy perforrnan;for$this computer analysis
• Non-standard roof reflectance
• Insulation below roof deck
• Window overhangs and/or fins
• Pipe insulation, all lines
Registration Number: 217-Po10128020E-000-000-0000000-0000 Registration Date/Time: 2017-06-28 17:23:50 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-28 16:43:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name: Monterra Plan 4 Calculation Date/Time: 16:40, Wed, Jun 28, 2017 Page 4 of 9
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 4-17.ribd16x
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
• --None
BUILDING - FEATURES INFORMATION ?3
01
02
03...
04
05
06
07
Project Name
�„ -
Conditioned Floof Area (ft2)
Number of Dwelling
Numbei of Bedrooms
Number of Zonesy
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
�Unitsl
Monterra Plan 4
3650e
1
)
0
1
ZONE INFORMATION �� : ra;� < to r"N. .:
N>>' Ce,'
01
02
R • «03
04
06—
06
07
Zone Floor Area
Avg. Ceiling
Zone Name
Zone Type
HVAC System Name
(ft2)
Height
Water Heating System 1
Water Heating System 2
Plan 4
Conditioned
HVAC 1, 2 & 31
3650
9
DHW Sys 1
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ftZ)
Window & Door Area (ftZ)
Tilt (deg)
N Wall
Plan 4
R-21 Wall (W.19.2x6.16)
0
Front
860
244.019
90
E Wall
Plan 4
R-21 Wall (W.19.2x6.16)
90
Left
730
73
90
S Wall
Plan 4
R-21 Wall (W.19.2x6.16)
180
Back
860
282.5
90
W Wall
Plan 4
R-21 Wall (W.19.2x6.16)
270
Right
750
117.5
90
R-38 Roof
Plan 4
R-38 Roof(R.38.2x14.16)
3650
Registration Number: P17-P010128020E-000-000-0000000-0000 Registration DateRme: 2017-06-28 17:23:50 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-05232017-695 Report Generated at: 2017-06-28 16:43:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:40, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-17.ribdl6x
CF1 R-PRF-01
Page 5 of 9
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Plan 4
Attic RoofPlan 4
Unventilated
4.36764
0.19
0.92
No
No
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
1.5X8 F
Window
N Wall (Front-0)
1.3
8.0
1.154
12.0
0.32
0.24
Insect Screen (default)
3.5X8 FD
Window
N Wall (Front-0)
3.5
8.0
1
1 28.0
0.32
10.24
Insect Screen (default)
1.5X8 F 2
Window :'_>
N Wall (Front-0)
1.3
8.0
1.154
12.0
0.32
0.24
Insect Screen (default)
16X8 PD
Window? ,'
N Wall (Front-0)
18.0
8.0
0.889
128.0
0.32
0.24
Insect Screen (default)
8X8 PD
Window
N Wall (Front-0)
----
----
1
64.0
0.32
0.24
Insect Screen (default)
2X5 SH
Wind ow
E Wall (Le4-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 SH 2
Windowwo
1Na11 (Left )9 )' ss
r =
0.32
0.24
(default)
Insect Screen default
3X5.5 SH
Window
E Wallr(L;eft-90,--:.
„ls�_;
�---'---
1 ¢
16.5
0.32
0.24
Insect Screen default
(default)
3X5.5 SH 2
Wiridow �
E'1Mall-(Left�90)� � 4
, ---
`� al M
0 "16 5
0.32
0.24
Insect Screen (default)
2X5 F
Window
E`1Nal L'eft90
(_ )
1
,10.0
0.32
0.24
Insect Screen (default)
2X5 F 2
Window
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
6X8 FD
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
5X4.5 SL
Window
S Wall (Back-180)
----
----
1
22.5
0.32
0.24
Insect Screen (default)
16X8 PD 2
Window
S Wall (Back-180)
16.0
8.0
1
128.0
0.32
0.24
Insect Screen (default)
6X8 FD 2
Window
S Wall (Back-180)
----
---
1
48.0
0.32
0.24
Insect Screen (default)
6X6 SL
Window
S Wall (Back-180)
----
-
1
36.0
0.32
0.24
Insect Screen (default)
2X5 F 3
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 4
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5.5SH
Window
W Wall (Right-270)
----
----
1
11.0
0.32
0.24
Insect Screen (default)
5X5.5 F
Window
W Wall (Right-270)
----
----
1
27.5
0.32
0.24
Insect Screen (default)
2X5.5 SH
Window
W Wall (Right-270)
----
----
1
11.0
0.32
0.24
Insect Screen (default)
3X8 FD
Window
W Wall (Right-270)
---
-
1
24.0
0.32
'0.24
Insect Screen (default)
Registration Number: 217-P010128020E-000-000-0000000-0000 Registration DateMme: 2017-06-28 17:23:50 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-28 16:43:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:40, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-17.ribdl6x
CF1 R-PRF-01
Page 6 of 9
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door
W Wall
24.0
0.50
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
1.5X8 F
10
0.1
10
10
0
0
0
0
0
0
0
0
0
3.5X8 FD
10
0.1
10
10
0
0
0
0
0
0
0
0
0
1.5X8 F 2
10 s''+:
0.1
10
10
0
0
0
0
0
0
0
0
0
16X8PD
4;'
0.1
4
4
0
0
0
0
0
0
0
0
0
16X8PD2
4
;:01::.
4
4
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS''s
01
02
03
Iff �04 y £`
OSy
06
07
//d
,1SS
Total Cavity
ulNmtgpD•'esign
Construction Name
Surface Type
C�gnstrucUon Types
t u. Framing �,,
R,,value,
11
U,value
z
Assembly Layers
"
5 ,0,
� a
V
Under Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofPlan 4
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof(R.38.2xl4.16)
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall (W.19.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
Plan 4
430
52
None
0.8
No
Hard Surface Slab
Plan 4
3220
263
None
0.8
No
Registration Number: 217-Po10128020E-000-000-0000000-0000 Registration DateRme: 2017-06-28 17:23:50 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-28 16:43:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:40, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 4-17.ribdl6x
CF1 R-PRF-01
Page 7 of 9
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
---
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1 (1)
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
Tank
Energy
Tank Insulation
Tank Location or
Heater
Number
Volume
Factor or
Input
R-value
Standby Loss /
Ambient
Name
Element Type
Tank Type
of Units
(gal)
Efficiency
Rating/Pilot
(Int/Ext)
Recovery Eff
NEEA Heat Pump Type
Condition
0
DHW Heater 1
Gas s_
,',Small Storage
"1
; 75-1
..0.58 EF
65,000 Btu/hr
R-0
n/a
n/a
SPACE CONDITIONING SYSTEMS ' " 'M
K. .'
01�.
02».&
03
�� D4, �.:
OS
06
SC Sys Name"
System Type..,
Heating lJnt Name
Cooling.�Umt Name
Fan Name
Distribution Name
Other eating and Cooling
n�
'
HVAC 1, 2 8 31
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFurnace
3
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Efficiency
Name
System Type
Number of Units
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
3
12.2
14.5
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Registration Number: 217-P010128020E-000-000-0000000-0000 Registration Date/Time: 2017-06-28 17:23:50 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-28 16:43:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 4 Calculation Date/Time: 16:40, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 4-17.ribd16x
CFI R-PRF-01
Page 8 of 9
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
%=- 02
03
04
05
06
07
08
Name•9,
Duct Leakage
::•Verification,.,.
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
HVAC -FAN SYSTEMS w
01
x gOAIKv�t 02 .€
L
�f 03
04
Name
Type:
tC..
jFan"Power"(WatYs(CFM)
aS n
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan -
pee
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
67
0.25
Default
0
Required
Registration Number: 217-PO10128020E-000-000-0000000-0000 Registration DateMme: 2017-06-28 17:23:50 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-05232017-695 Report Generated at: 2017-06-28 16:43:56
CERTIFICATE OF COMPLIANCE- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
-Project Name: Monterra Plan 4 Calculation Date/Time: 16:40, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 4-17.ribdl6x
CF1 R-PRF-01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tci'�cei
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2017-06-28 17:23:50
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under, the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design featuresYor system'designfeatures identified-owthis Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans an,specifications submitted tothe enforcemenJe ncy for apoval.riththisbilding permit application.
Responsible Designer Name: ` y- A
-,
Responsible Designer Signature
�eeiL`
Tim Scott ? :. I,
W
�..
Company: y a «
Datetzl.fSigned. f
CY,
Scott Design and Title 24, Inc.
2017-06-28 17.23.50
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 217-P010128020E-000-000-0000000-0000 Registration DateMme: 2017-06-28 17:23:50
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-05232017-695
RE 2.
a
Easy to Verify
at CaICERTS.com
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-28 16:43:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 08:11, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 3-17.ribd16x
CF1 R-PRF-01
Page 1 of 10
GENERAL INFORMATION
01
Project Name
Monterra Plan 3
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.2.1 (695)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.1
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft)
3370
15
Number of Zones
1
16
Slab Area (ff)
3370
17
Number of Stories
1
18
Addition Cond. Floor Ai6a
n/a
19
Natural Gas Available
Yes
20
2"
Addition Slab Areal (ft.;)
n/a
21
Glazing Percentage (%)
20.7%
COMPLIANCE RESULTS y.
01
Building Complies with Computer Performance ; ,{
��n.
«N�
02
.... �,. ,a% `�3 ��£� 6s,`"`'' S �°% "F �h=zaz.. �u ' vCn:
This building incorporates features that require field testing and/ Fverificatio n by°a ceft�ed HERS rate under the supennsion of a CEC approved HERS provider.
03
This building incorporates one or moreSpecial Featiyre'ssho"wn below �V1
E R a
`
Z�
o�
V
M
ZD
-t
Registration Number: 217-Po10128012F-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
g,TLf22a1 7 -ovt)5
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED. '
FOR CONSTRUCTION t:
DATE g�i1 BY
pLAd\1
p�� a
Registration Da e:
Report Version - CF1 R-05232017-695
09:22:23 HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-30 08:12:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3
Calculation Description: Title 24 Analysis
Calculation Date/Time: 08:11, Fri, Jun 30, 2017
Input File Name: Monterra-Plan 3-17.ribdl6x
CF1 R-PRF-01
Page 2 of 10
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.78
1.42
_
0.36
20.2%
Space Cooling
85.39
75.56
9.83
11.5%
IAQ Ventilation
0.87
0.87
0.00
0.0%
Water Heating
3.90
6.86
-2.96
-75.9%
PV Credit
----
0.00
0.00
\
North Facing Compliance Total
91.94
84.71
7.23
7.9%
Space Heating
1.78
1.66
0.12
6.7%
Space Cooling
85.39
82.01
3.38
4.0%
IAQ Ventilation
0.87
0.87
0.00
0.0%
Water Heating
gt
3.90
6.86
-2.96
-75.9%
PV Credits
'
0.00
0.00
-
East Facing Compliance Total;> �.,,,...
91.94
91.40
0.54
0.6%
Space Heating
, ,i
1.78
2.75
-0.97
-54.5%
Space Cooling
_ 8�5 39�;
78 25
err.
7.14
8.4%
IAQ Ventilation r
0 87
0 87
C
0.00
0.0%
Water Heating
6 6
-2.96
-75.9%
PV Credit $,
� 'Ilk
"'
1-a- R
0
�< R
0.00
-
South Facing Compliance Total
91.94
88.73
3.21
3.5%
Space Heating
1.78
2.19
-0.41
-23.0%
Space Cooling
85.39
73.31
12.08
14.1%
IAQ Ventilation
0.87
0.87
0.00
0.0%
Water Heating
3.90
6.86
-2.96
-75.9%
PV Credit
-
0.00
0.00
----
West Facing Compliance Total
91.94
83.23
8.71
9.5%
Registration Number: 217-P010128012F-000-000-0000000-0000. Registration Date/Time: 2017-06-30 09:22:23 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-30 08:12:56
r
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 08:11, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 3-17.ribdl6x
CF1 R-PRF-01
.Page 3 of 10
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC). A score of zero represents the energy performance of a building
that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6
(such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under
Title 24, Part 11 (CALGreen). .
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV
Final EDR of Proposed Design
North
50.6 -
47.5
0.0
47.5
East
50.6
50.4
0.0
50.4
South
50.6 P.
49.3
0.0
49.3
West
50.6
46.9
0.0
46.9
❑
Design meets Tier 1 requirement.& 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification,prerequisite.
❑
Design meets Tier 2 requiremenfof 166%ors-greater code, compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirrement,for Single Family. ncllimate zone CZ1,5 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
photovoltaic PV renewableener �n"` + p ( ) gy generation sufficientto�achiievve a Final Energy Design Rating (EDR) of zed Iess..The PV System must be verified.
,.or
REQUIRED SPECIAL FEATURES
The following are features that must be installed as conditionxfor meetinglthegTodefted energy performance for this computer analysis 7 0,
• Non-standard roof reflectance
• Insulation below roof deck
• Window overhangs and/or fins
• Pipe insulation, all lines
Registration Number: 217-P010128012F-000-000-0000000-0000 Registration Date/Time: 2017-06-30 09:22:23 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-30 08:12:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3
Calculation Description: Title 24 Analysis
HERS FEATURE SUMMARY
Calculation Date/Time: 08:11, Fri, Jun 30, 2017
Input File Name: Monterra-Plan 3-17.ribd16x
CF1 R-PRF-01
Page 4 of 10
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
• --None --
BUILDING - FEATURES INFORMATION `
01
02'�`;
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwellingoffim
Units
Number ofBedrooms
Number of Zonesp
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Monterra Plan 3
3370 h,
1
�3
1
0
1
ZONE INFORMATION 1 C, ��,�. ?
01
02
v R03
04
09,
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Plan 3
Conditioned
HVAC 1 & 21
3370
9
DHW Sys 1
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ftft2)
Tilt (deg)
N Wall
Plan 3
R-21 Wall (W.19.2x6.16)
0
Front
720
91.6
90
E Wall
Plan 3
R-21 Wall (W.19.2x6.16)
90
Left
1061
192.5
90
S Wall
Plan 3
R-21 Wall (W.19.2x6.16)
180
Back
727
356.064
90
W Wall
Plan 3
R-21 Wall (W.19.2x6.16)
270
Right
1030.
78
90
R-38 Roof
Plan 3
R-38 Roof(R.38.2x14.16)
3370
Registration Number: 217-P010128012F-000-000-0000000-0000 Registration Date/Time: 2017-06-30 09:22:23 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 . Report Generated at: 2017-06-30 08:12:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 08:11, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 3-17.ribdl6x
CF1 R-PRF-01
Page 5 of 10
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Plan 3
Attic RoofPlan 3
Unventilated
4.36764
0.19
0.92
No
No
FA
s
F' P* R E
Registration Number: 217-P010128012F-000-000-0000000-0000 Registration Dateffime: 2017-06-30 09:22:23 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-30 08:12:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 08:11, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-17.ribdl6x
CF1 R-PRF-01
Page 6 of 10
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
1.5X8 F
Window
N Wall (Front-0)
2.0
8.0
0.75
12.0
0.32
0.24
Insect Screen (default)
3.6X8 FD
Window
N Wall (Front-0)
3.5
8.0
1 1
28.0
1 0.32
0.24
Insect Screen (default)
1.5X8 F 2
Window
N Wall (Front-0)
2.0
8.0
0.75
12.0
0.32
0.24
Insect Screen (default)
3X6 SH
Window
N Wall (Front-0)
----
----
1
18.0
0.32
0.24
Insect Screen (default)
2X5 F
Window
E Wall (Left-90)
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 2
Window
E Wall (Left-90)
----
----
1
10.0
0.32
1 0.24
Insect Screen (default)
2X5.5 SH
Window
E Wall (Left-90)
----
----
1
1 11.0
0.32
0.24
Insect Screen (default)
5X5.5 F
Window
E Wall (Left-90)
----
----
1
27.5
0.32
0.24
Insect Screen (default)
2X5.5 SH 2
Window; ; _''.
E Wall (Left-90)
----
----
1
11.0
0.32
0.24
Insect Screen (default)
2X5 F 3
Window',
E Wall (Left-90)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
10X8 PD
"< . ;Window
-E'Wall`(Left-90)
::..
----
----
1
80.0
0.32
0.24
Insect Screen (default)
5X5 C
Window
,; "E Wall Left90�
(,. ?.i as
may;:
y
x 1
_25.0
0.32
0.24
Insect Screen (default)
2X4 C
Window <
E Wall ('Left 9l3} :
-
�1 1. 4
K 8.0
0.32
0.24
Insect Screen (default)
6X6 SL
Window
. ..
"'r5>WaII (BacOi-W A-Am4:
W-A A
1
36A0
0.32
0.24
Insect Screen (default)
6X8 FD
Window
S'Wall'( ck!1°80) P
R19.0�
8.0
0.3
48.0
0.32
0.24
Insect Screen (default)
16X8 PD
Window
S Wall (Back-180)
----
--
1
128.0
0.32
0.24
Insect Screen (default)
5X6 SL
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
5X6 SL 2
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.24
Insect Screen (default)
6X8 FD 2
Window
S Wall (Back-180)
19.0
8.0
0.316
48.0
0.32
0.24
Insect Screen (default)
2X5 F 4
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 5
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X4 SH
Window
W Wall (Right-270)
----
----
1
8.0
0.32
0.24
Insect Screen (default)
5X4 SL
Window
W Wall (Right-270)
----
----
1
20.0
0.32
0.24
Insect Screen (default)
2X6 SH
Window
W Wall (Right-270)
----
----
1
6.0
0.32
0.24
Insect Screen (default)
6X8 FD 3
Window
W Wall (Right-270)
----
----
1
24.0.
0.32
0.24
Insect Screen (default)
Registration Number: 217-P010128012F-000-000-0000000-0000 Registration DateMme: 2017-06-30 09:22:23 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-05232017-695 Report Generated at: 2017-06-30 08:12:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 08:11, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-17.ribdl6x
CF1 R-PRF-01
Page 7 of 10
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door
N Wall
21.6
0.50
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
1.5X8 F
10
0.1
10
10
0
0
0
0
0
0
0
0
0
3.6X8 FD
10
0.1
10
10
0
0
0
0
0
0
0
0
0
1.5X8F 2
10;-':
0.1
10
10
0
0
0
0
0
0
0
0
0
6X8 FD
14; j '',
0.1
14
14
0
0
0
0
0
0
0
0
0
6X8 FD 2
14
14
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS -
:.
01
02`
Q3
' '' In"
OS r
"P6
07
Toil Ca�
1WmterDesign
Construction Name
Surface Type
Co struction Type»..
Framing c
4-valuea3 a
.» VU value
Assembly Layers
' `' I. '"
V . 1—
W A
Under Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofPlan 3
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof(R.38.2xl4.16)
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over. Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall (W.19.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
Plan 3
521
61
None
0.8
No
Hard Surface Slab
Plan 3
2849
280
None
0.8
No
Registration Number: 217-P010128012F-000-000-0000000-0000 Registration DateMme: 2017-06-30 09:22:23 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-30 08:12:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 08:11, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-17.ribd16x
CF1 R-PRF-01
Page 8 of 10
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
---
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1 (1)
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
E,
Tank
Energy
Tank Insulation
Tank Location or
Heater
Number
Volume
Factor or
Input
R-value
Standby Loss /
Ambient
Name
Element Type
TaOype
of Units
(gal)
Efficiency
Rating/Pilot
(Int/Ext)
Recovery Eff
NEEA Heat Pump Type
Condition
DHW Heater 1
Gas ..
Small Storage
1
75 r•.:k-
0.58 EF
65,000 Btu/hr
R-0
n/a
/n
n/a
SPACE CONDITIONING SYSTEMS = V-%
` _
All
01 ` ,•
02 ...,.
.: �m.03 1x
y
04
05
06
SC Sys Name
System Type uN,.
Heating Unit Name
Coolling,$Unit Name
Fan Name
Distribution Name
Other Heating and Cooling
' % "
HVAC 1 & 21
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFurnace
2
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Efficiency
Name _
System Type
Number of Units
EER . SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
2
12.2
14.5
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Registration Number: 217-P010128012F-000-000-0000000-0000 Registration DateMme: 2017-06-30 09:22:23
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-30 08:12:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 08:11, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 3-17.ribd16x
CF1 R-PRF-01
Page 9 of 10
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
:92
03
04
05
06
07
08
Name
Duct Leakage
VenfidatFon,,,,—,,. _
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Not Required ^
Not Required
Not Required
Not Required
Required
HVAC -FAN SYSTEMS
01 y.'.
gy,:
a'.\...-i �Gm'1. �. 8:02�..,. ''. c EiEid
�'. •�'.'.3`
04
Name '`
�;
TYPe `_ >; r
Fan Power"(Watts.CFM)
v/ %
HERS Verification
HVAC Fan 1
Single Speed PS'C Furnace Fan
0.58 V
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts%CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
64
0.25
Default
0
Required
Registration Number: P17-P010128012F-000-000-0000000-0000 Registration DateRme: 2017-06-30 09:22:23 HERS Provider: . CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-30 08:12:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 3 Calculation Date/Time: 08:11, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 3-17.ribdl6x
CF1 R-PRF-01
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2017-06-30 09:22:23
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211.
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, underthe laws of the State of California:
1. 1 am eligible under Division 3 of the Busine"ss`and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design`features identified, owthis"Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to�the enforcement agency fog aprovalwithfthis�building permit application.
Responsible Designer Name: jpoD
Resesigner Signature €
Tim Scott 6'Y�
Y �'
_ , -
v
Company: ; ,
Scott Design
Daie.Signed y
and Title 24, Inc.
2017-06-30 09:22:23
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 217-P010128012F-000-000-0000000-0000 Registration DateMme: 2017-06-30 09:22:23
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695
❑'E ❑''
T
■■
r;
a
Easy to Verify
at CaICERTS.com
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-30 08:12:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 16:31, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 2-17.ribd16x
CFI R-PRF-01
Page 1 of 9
GENERAL INFORMATION
01
Project Name
Monterra Plan 2
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.2.1 (695)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.1
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft)
3220
15
Number of Zones
1
16
Slab Area (ft2)
3220
17
Number of Stories
1
'18
Addition Cond. Floor Area
n/a
19
Natural Gas Available
Yes _
20
Addition Slab Area (ft.,y
n/a
21
Glazing Percentage (%)
19.8%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance r �r
02
This building incorporates features that require field testing�and/orvificationby certified HERS r er under the superisio of a CEC approved HERS provider.
03
This building incorporates "'or mo 64S' ial Featuresmshow below"?
'
z P R Q I
D E R
16
zn _
Z�
M
C
O t—
®�
c o
-a
Z v
MD
gistration Number: 217-Po10128005E-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential C
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPF130VED
FOR CONSTRUCTION
DATES g �� BY IF
Registration Dateffime:
2017-06-28 17:20:47 HERS Provider: CaICERTS inc.
7-695 Report Generated at: 2017-06-28 16:32:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 16:31, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-17.ribdl6x
CFI R-PRF-01
Page 2 of 9
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.47
1.88
-0.41
-27.9%
Space Cooling
83.66
71.12
12.54
15.0%
IAQ Ventilation
0.89
0.89
0.00
0.0%
Water Heating
4.08
7.18
-3.10
-76.0%
PV Credit
----
0.00
0.00
North Facing Compliance Total
90.10
81.07
9.03
10.0%
Space Heating
1.47
1.79
-0.32
-21.8%
Space Cooling
83.66
78.02
5.64
6.7%
IAQ Ventilation
0.89
0.89
0.00
0.0%
Water Heating
4.08
7.18
-3.10
-76.0%
PV Credit:
>>,
----
0.00
0.00
----
East Facing Compliance Total
't
90.10
87.88
2.22
2.5%
-...
Space Heating
Space Cooling '
1.47
3 66
883C
WA
1.62
71 28
-0.15
12.38
-10.2%
14.8%
IAQ Ventilation ;
,
�} ;
0 89
0 89
'c n c
0.00
0.0%
x-�
Water Heating
dnow
08
,:,:
3.10
76.0%
�3
PV Credit g 4 r
„;
_
P
0 00
� E
0.00
----
.,
South Facing Compliance Total
90.10
80.97
9.13
10.1%
Space Heating
1.47
1.72
-0.25
-17.0%
Space Cooling
83.66
77.22
6.44
7.7%
IAQ Ventilation
0.89
0.89
0.00
0.0%
Water Heating
. 4.08
7.18
-3.10
-76.0%
PV Credit
----
0.00
0.00
----
West Facing Compliance Total
90.10
87.01
3.09
3.4%
Registration Number: 217_P010128005E-000-000-0000000-0000 Registration Dateffime: 2017-06-28 17:20:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-05232017-695 Report Generated at: 2017-06-28 16:32:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 16:31, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-17.ribdl6x
CFI R-PRF-01
Page 3 of 9
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC). A score of zero represents the energy performance of a building
that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6
(such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under
Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV
Final EDR of Proposed Design
North
50.6
46.7
0.0
46.7
East
50.6
49.6
0.0
49.6
South
50.6
46.6
0.0
46.6
West
50.6 `;
49.2
0.0
49.2
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2=requirement of 30%orvgreatercode compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirementfor Single ,,Family in climate.zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
s9
photovoltaic PV renewable',ever A i a �N �.,�;
p ( )gy generation s�ufficienttoacheYe a Ffna( Energy Design Rating (EDR) of zero or less. The PV System must be verified.
REQUIRED SPECIAL FEATURES �<:. . 411a,
..
The following are features that must be installed as conditi%for meeting€the modealed energy perfortnance;forthls computer analysis. ..,,
• Non-standard roof reflectance
• Insulation below roof deck
• Window overhangs and/or fins
• Pipe insulation, all lines
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
-- None --
Registration Number: 217-P010128005E-000-000-0000000-0000 Registration DateMme: 2017-06-28 17:20:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-05232017-695 Report Generated at: 2017-06-28 16:32:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 16:31, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 2-17.ribdl6x
CF1 R-PRF-01
Page 4 of 9
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Monterra Plan 2
3220
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Plan 2
Conditioned
HVAC 1 & 21
3220
9
DHW Sys 1
OPAQUE SURFACES A
01
"- 02
03
04
05
06
07
08
Name
- 'Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
N Wall
- Plan 2
R721 Wall (W.19.2x6.16)
0
Front
740
217.6
90
E Wall
Plan 2
R,21 Walit 1�9 2x6:16)
90
1„ Left
880
69
90
S Wall
Plan 2
R 2: (WaII (W 19 2x6 16)
1,80
Back
740
292
90
W Wall
P•,lan 2 ¢}
R 21, Wa I. AM 2x6 16
g 270ftt
kigii
880
80
90
R-38 Roof
x T Plan 2 #rz
:, R-,38 Roof(R.38.2x14.16)
;; 3220
ATTIC
01
02
03
04
05
06
07
08
Name ,
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Plan 2
Attic RoofPlan 2
Unventilated
4.36764
0.19
0.92
No
No
Registration Number: 217-P010128005E-000-000-0000000-0000 Registration Date/Time: 2017-06-28 17:20:47 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-28 16:32:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 16:31, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-17.ribdl6x
CF1 R-PRF-01
Page 5 of 9
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
2X4.5 F
Window
N Wall (Front-0)
----
----
1
9.0
0.32
0.24
Insect Screen (default)
1.5X8 F
Window
N Wall (Front-0)
1.5
8.0
1
1 12.0
0.32
10.24
Insect Screen (default)
3.5X8 FD
Window
N Wall (Front-0)
3.5
8.0
1
28.0
0.32
0.24
Insect Screen (default)
1.5X8 F 2
Window
N Wall (Front-0)
----
----
1
12.0
0.32
0.24
Insect Screen (default)
2.5X6F
Window
N Wall (Front-0)
----
----
1
45.0
0.32
0.24
Insect Screen (default)
2.5X6F 2
Window
N Wall (Front-0)
----
----
1
45.0
0.32
0.24
Insect Screen (default)
2.5X6F 3
Window
N Wall (Front-0)
----
----
1
45.0
0.32
0.24
Insect Screen (default)
2X5 F
Window ;"`
E Wall (Left-90)
---
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 2
Window;
E Wall (Left-90)
----
1
10.0
0.32
0.24
Insect Screen (default)
2X4 SH
Window;
E Wall (Left-90)
----
----
1
8.0
0.32
0.24
Insect Screen (default)
3X5.5 SH
,Window
.; E;Wall`(1.eft-90)
----
1
16.5
0.32
0.24
Insect Screen (default)
6X5.5 SH
Window
%t=Wall (Left90)�
I -
16.5
0.32
0.24
Insect Screen (default)
2X4 SH 2
Wiridow
s�
E WaU (left 90j
-
' r
,1
Y.
8.0
0.32
0.24
Insect Screen (default)
6X8 FD
Window
8�WaI61c1 X118)}
0.32
0.24
Insect Screen (default)
20X8 Pd
Window
0. Udall (8ack1$0)20.t
8.0
1
160.0
0.32
0.24
Insect Screen (default)
6X8 FD 2
Window
S Wall (Back-180)
----
----
1
48.0
0.32
1 0.24
Insect Screen (default)
6X6 SL
Window
S Wall (Back-180)
----
----
1
36.0
0.32
1 0.24
Insect Screen (default)
2X5 F 3
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
2X5 F 4
Window
W Wall (Right-270)
----
----
1
10.0
0.32
0.24
Insect Screen (default)
6X6 SL 2
Window
W Wall (Right-270)
----
1
36.0
0.32
0.24
Insect Screen (default)
3X8 FD
Window
W Wall (Right-270)
----
1
24.0
1 0.32
0.24
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door
N Wall
21.6
0.50
Registration Number: 217-P010128005E-000-000-0000000-0000 Registration Date/Time: 2017-06-28 17:20:47 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-28 16:32:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 16:31, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-17.ribdl6x
CF1 R-PRF-01
Page 6 of 9
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Distl-
Bot Up
Depth
Top Up
Dist R
Bot Up
1.5X8 F
10
0.1
10
10
0
0
0
0
0
0
0
0
0
3.5X8 FD
10
0.1
10
10
0
0
0
0
0
0
0
0
0
20X8 Pd
14
0.1
14
14
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type.:;
Construction Type
Framing
R-value
U-value
Assembly Layers
• Under Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofPlan 2
"Attic Roofs'
Wood Framed Ceiling'in.
O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
w ,
Ceilings (below.
�,s£
v ,€i %
��
0�
Inside Finish: Gypsum Board
Cavity/Frame:R-9.1/2x4
R-38 Roof(R.38.2x14.16)
Wood Framed Ceiling
2x4 16 C
R 38
1s0.025
Over Ceiling Joists: R-28.9 insul.
attic) ,;.
@ m"O
.
Inside Finish: Gypsum Board
A
Cavity / Frame: R-21 / 2x6
R-21 Wall (W.19.2x6.16)
Exterior Walls
Wood Framed Wall"`°"
2x6 @ 16 in. O.C.
R 21
0:069
Exterior Finish: 3 Coat Stucco
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab
Plan 2
3220
231
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
---
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1 (1)
1
.0%
Registration Number: 217-P010128005E-000-000-0000000-0000 Registration DatelTime: 2017-06-28 17:20:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-28 16:32:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2 Calculation Date/Time: 16:31, Wed, Jun 28, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 2-17.ribd16x
CF1 R-PRF-01
Page 7 of 9
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
Tank
Energy
Tank Insulation
Tank Location or
Heater
Number
Volume
Factor or
Input
R-value
Standby Loss /
Ambient
Name
Element Type
Tank Type
of Units
(gal)
Efficiency
Rating/Pilot
(Int/Ext)
Recovery Eff
NEEA Heat Pump Type
Condition
DHW Heater 1
Gas
Small Storage
1
75
1 0.58 EF
1 65,000 Btu/hr
R-0
n/a
/n
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05•
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC 1 & 21
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01 is--;` w.;
02
03
04
Name
... System Type
Number of Units
Efficiency
Heating Component 1 ;.
Cntrl Furnace
2
80 AFUE
HVAC - COOLING UNIT TYPES il x 1 ' ``" 11
01
02 z„ -
D3 3N -
'; r04
05 V'
se a 06
07
08
I-
I � `.
Efficiency
Name
System Type
Number of Units
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
2
12.2
14.5
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
1-hers-dist
Registration Number: 217-P010128005E-000-000-0000000-0000 Registration DateMme: 2017-06-28 17:20:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-28 16:32:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2
Calculation Description: Title 24 Analysis
Calculation Date/Time: 16:31, Wed, Jun 28, 2017
Input File Name: Monterra-Plan 2-17.ribdl6x
CF1 R-PRF-01
Page 8 of 9
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 3i'
02
03
Name ?< , ,:
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan F,
Required
0.58
IAQ (Indoor Air Quality) FANS
0102`'
03
s% 04� .,
05
06
Dwelling Unit
7 � €, IAQ CFM
m 11 JA�Q'WattsICFM
IAQ`fann Tye
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
;rs'F 62
0.25-" R, : Q
x
4d 1 efiauF Hit
0
Required
Registration Number: 217-P010128005E-000-000-0000000-0000 Registration DateMme: 2017-06-28 17:20:47 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-28 16:32:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 2
Calculation Description: Title 24 Analysis
Calculation Date/Time: 16:31, Wed, Jun 28, 2017
Input File Name: Monterra-Plan 2-17.ribdl6x
CFI R-PRF-01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2017-06-28 17:20:47
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under"ihe laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
�x
Regulations.
3. The building design featuresV'or systen `design features id nene tified-on-this'Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and sspecifications submitted tie enforcement agency for approval with thip building permit application.
Responsible Designer Name:
x��
Responsible Des&gner Signature T
Tim Scott
♦G�Y(i�Cdi/`
� .�
Company:
Date Signed
Scott Design and Title 24, Inc.
2017-06-28 17:20:47
Address:
License:
77085 Michigan Drive
NA
City/State/Zip: -
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 217-P010128005E-000-000-0000000-0000 Registration Date/Time: 2017-06-28 17:20:47
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695
0'.
Easy to Verify
at CaICERTS.com
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-28 16:32:58
_CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
, Project Name: Monterra Plan 1 Calculation Date/Time: 08:35, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-17.ribdl6x
CFI R-PRF-01
Page 1 of 9
GENERAL INFORMATION
01
Project Name
Monterra Plan 1
02
Calculation Description
Title 24 Analysis
03
Project Location
55-101 Monroe
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.2.1 (695)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.1
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft)
3180
15
Number of Zones
1
16
Slab Area (ft2)
3180
17
Number of Stories
1
18
Addition Cond. Floor Area
n/a
19
Natural Gas Available
Yes
20
Addition Slab Ar4(ft2)
.n/a
21
Glazing Percentage (%)
16.7%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance �^ A"",
02
This building incorporates featuresahat require field testing�and/overificationtiy a certlfie d HRS aterunder the supervision of a CEC-approved HERS provider.
03
This building incorporates,.one or more Special Fea ivWshb n below ;
19 9 W ��
a a
IPP'.
Z0
0
r
-v
rill
,Zia
Ngistration Number: 217-P010127994G-000-000-0000000-0000
**c7A Building Energy Efficiency Standards - 2016 Residential Compliance
7 - 000
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE 136fiLl BY
FLAcr...j
%% -- — —-
- CF1 R-05232017-695
7-06-30 09:18:44
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-30 08:36:11
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
` Project Name: Monterra Plan 1 Calculation Date/Time: 08:35, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-17.ribd16x
CF1 R-PRF-01
Page 2 of 9
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.44
1.21
0.23
16.0%
Space Cooling
79.37
68.93
10.44
13.2%
IAQ Ventilation
0.89
0.89
0.00
0.0%
Water Heating
4.13
7.27
-3.14
-76.0%
PV Credit
----
0.00
0.00
----
North Facing Compliance Total
85.83
78.30
7.53
8.8%
Space Heating
1.44
1.79
-0.35
-24.3%
Space Cooling
79.37
74.40
4.97
6.3%
IAQ Ventilation
0.89
0.89
0.00
0.0%
Water Heating 3
4.13
7.27
-3.14
-76.0%
PV Credit
0.00
0.00
East Facing Compliance Total .
85.83
84.35
1.48
1.7%
Space Heating
1.44.
2.30
-0.86
-59.7%
Space Cooling
79 37
86.64
yjr,',;
12.73
16.0/o
IAQ Ventilation r .
0 89
0.89
-
0.00
0.0%
Water Heating ,r
4 13
7:27
3.14
-76.0%
PV CreditQ,,.
� . R .. �
1 0i.00y
�" �
0.00
South Facing Compliance Total
85.83
77.10
8.73
10.2%
Space Heating
1.44
1.64
-0.20
-13.9%
Space Cooling
79.37
71.05
8.32
10.5%
IAQ Ventilation
0.89
0.89
0.00
-0.0%
Water Heating
4.13
7.27
-3.14
-76.0%
PV Credit
----
0.00
0.00
- -
West Facing Compliance Total
85.83
80.85
4.98
5.8%
Registration Numiber:"P17-P010127994G-000-000-0000000-0000 Registration DateMme: 2017-06-3009:18:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-30 08:36:11
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 08:35, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis Input File Name: Monterra-Plan 1-17.ribd16x
CF1 R-PRF-01
Page 3 of 9
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC). A score of zero represents the energy performance of a building
that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6
(such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under
Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV
Final EDR of Proposed Design
North
49.5
46.2
0.0
46.2
East
49.5
48.8
0.0
48.8
South
49.5
45.7
0.0
45.7
West
49.5 z ;
47.3
10.0
147.3
❑
Design meets Tier 1 requiremen61"l:5% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2irequirement of 30%u; or greater -code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family., in.climate.zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
photovoltaic (PV) renewable'energy generation stiff c e t to�ach7e# a Fin nergy Design Rati g (EDR) of zerro or less The PV System must be verified.
REQUIRED SPECIAL FEATURES
The following are features that must be installed as conditi0n1for meet modeled energy perfor�narlce;forthis computer analysis,
• Non-standard roof reflectance • g> -
• Insulation below roof deck
• Window overhangs and/or fins
• Pipe insulation, all lines
a
Registration Number: 217-Po10127994G-000-000-0000000-0000 Registration Date/Time: 2017-06-30 09:18:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-30 08:36:11
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 08:35, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis
HERS FEATURE SUMMARY
Input File Name: Monterra-Plan 1-17.ribd16x
CF1 R-PRF-01
Page 4 of 9
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
-- None --
BUILDING - FEATURES INFORMATION
01
02
03..
04
05
06
07
Number of Dwelhngm.
�i
�
i
Number of Ventilation
Number of Water
Project Name
Conditioned Floor"Area (ft2)
Umts
ENumbej of Bedrooms
Numb'fr of�lones
Cooling Systems
Heating Systems
Monterra Plan 1
3180
1 � �
�"�3 �
� ;' 1
0
1
ZONE INFORMATION b5,u:w 0 mom;
01
02
a03
04
05
06
07
Zone Floor Area
Avg. Ceiling
Zone Name
Zone Type
HVAC System Name
(ft)
Height
Water Heating System 1
Water Heating System 2
Plan 1
Conditioned
HVAC 1 & 21
3180
8
DHW Sys 1
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
N Wall
Plan 1
R-21 Wall (W.19.2x6.16)
0
Front
740
189.564
90
E Wall
Plan 1
R-21 Wall (W.19.2x6.16)
90
Left
880
64
90
S Wall
Plan 1
R-21 Wall (W.19.2x6.16)
180
Back
740
228
90
W Wall
Plan 1
R-21 Wall (W.19.2x6.16)
270
Right
880
72
90
R-38 Roof
Plan 1
R-38 Roof(R.38.2x14.16)
3180
.Registration Number: 217-P010127994G-000-000-0000000-0000 Registration Date/Time: 2017-06-30 09:18:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-30 08:36:11
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 08:35, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-17.ribdl6x
CF1 R-PRF-01
Page 5 of 9
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance.
Roof Emittance
Radiant Barrier
Cool Roof
Attic Plan 1
Attic RoofPlan 1
Unventilated
4.36764
0.19 .
0.92
No
No
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
Window 1
Window
N Wall (Front-0)
1.5
8.0
1
12.0
0.32
0.23
Insect Screen (default)
Window 2
Window
N Wall (Front-0)
3.3
8.0
0.985
26.0
0.32
0.23
Insect Screen (default)
Window 3
Window
N Wall (Front-0)
1.5
8.0
1
12.0
0.32
0.23
Insect Screen (default)
Window 4
Window}. ",;;
N Wall (Front-0)
15.0
8.0
0.983
118.0
0.32
0.23
Insect Screen (default)
Window 5
Window.x` ''
c E Wall (Left-90)
----
----
1
20.0
0.32
0.23
Insect Screen (default)
Window 6
:.Window
.F E'Wall (Left-90)
----
1
20.0
0.32
0.23
Insect Screen (default)
Window 7
Window „
: r'EWall Left90 E�
�( y . )
1
1 .
24.0
2
0.32
0.23
Insect Screen (default)
Window 8
Window
( �) q
S WaIII� BacK 180
-
E 1 s=.
y 48.0
0.32
0.23
Insect Screen (default)
Window 9
Wiridow
�S�WaI (BacIA86rwol, PM'
AR.
-
� -
1
6!0
0.32
0.23
Insect Screen (default)
Window 10
Window
S-Wall (.Back 1�80) P
H =
-
1L
36.0
0.32
0.23
Insect Screen (default)
Window 11
Window
S Wall (Back-180)
----
----
1
6.0
0.32
0.23
Insect Screen (default)
Window 12
Window
S Wall (Back-180)
----
1
36.0
0.32
0.23
Insect Screen (default)
Window 13
Window
S Wall (Back-180)
----
1
48.0
0.32
0.23
Insect Screen (default)
Window 14
Window
S Wall (Back-180)
----
----
1
48.0
0.32
0.23
Insect Screen (default)
Window 15
Window
W Wall (Right-270)
1
10.0
0.32
0.23
Insect Screen (default)
Window 16
Window
W Wall (Right-270)
----
----
1
10.0
1 0.32
0.23
Insect Screen (default)
Window 17
Window
W Wall (Right-270)
----
-
1
52.0
1 0.32
0.23
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door
N Wall
21.6
0.50
Registration Number: 217-P010127994G-000-000-0000000-0000 Registration Dateffime: . 2017-06-30 09:18:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-30 08:36:11
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 08:35, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-17.ribd16x
CF1 R-PRF-01
Page 6 of 9
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
Window 1
10
0.1
10
10
0
0
0
0
0
0
0
0
0
Window 2
10
0.1
10
10
0
0
0
0
0
0
0
0
0
Window 3
10
0.1
10
10
0
0
0
10
0
0
0
0
0
Window 4
10
0.1
10
10
0
0
0
1 0
0
0
0
1 0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type.; `-;
Construction Type
Framing
R-value
U-value
Assembly Layers
>°4 `°
Under Roof Joists: R-0.0 insul.
• Cavity /Frame: R-13.0 / 2x4 To P Chrd
M:
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofPlan 1
Attic Roofs
Wood Framed Ceilingrn0
Cp`14
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
Ceilings (belowF�
��
Inside Finish: Gypsum Board.
Cavity/Frame: R-9.1 /2x4
�. fir.
�R
R-38 Roof(R.38.2x14.16)
attic)..'"11Uood
Framed Cng
2x4 @ 16 in O C _
w 38
0"025
Over Ceiling Joists: R-28.9 insul.
1
k ri i l�
A. :�o "` " 10
V 1.� 1
` M,
Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall (W.19.2x6.16)
I Exterior Walls 1
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
Plan 1
3180
224
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
---
Registration Number: 217-P010127994G-000-000-0000000-0000 Registration DateTme: 2017-06-30 09:18:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-30 08:36:11
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
�5 Project Name: Monterra Plan 1 Calculation Date/Time: 08:35, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-17.ribdl6x
CF1 R-PRF-01
Page 7 of 9
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type -
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1 (1)
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
Tank
Energy
Tank Insulation
Tank Location or
Heater
Number
Volume
Factor or
Input
R-value
Standby Loss /
Ambient
Name
Element Type
Tank Type
of Units
(gal)
Efficiency
Rating/Pilot
(Int/Ext)
Recovery Eff
NEEA Heat Pump Type
Condition
DHW Heater 1
Gas
Small Storage
1
75
0.58 EF
65,000 Btu/hr
R-0
n/a
0
n/a
SPACE CONDITIONING SYSTEMS
01
°" 02
03
04
05
06
SC Sys Name f
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC 1 & 21
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
i � f-
0 z
HVAC -HEATING UNIT TYPES
f�
01
F
a
W. a D3
04
Name r"
� � v
""' � System Type � �,, � v,;;
sz:- :a
y� Number of Units
Efficiency
Heating Component 1
CntrlFurnace
2
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Name
System Type
Number of Units
Efficiency
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
2
12.2
14.5
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
,Registration Number: 217-P010127994G-000-000-0000000-0000 Registration DateMme: 2017-06-30 09:18:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-30 08:36:11
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 08:35, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-17.ribd16x
CFI R-PRF-01
Page 8 of 9
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
HVAC -FAN SYSTEMS
01
02
03
04
Name <'
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 12:
- -Single, Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION10: "u
.. ,
'Ile..,..
01 ,...
Or
li , . 02
03
Name _
Verified Fan Watt DFaw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Ih,..°
6
f .� P Rye uirecl R� �
q.;
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
62
0.25
Default
0
Required
Registration Number: 217-P010127994G-000-000-0000000-0000 Registration Date/Time: 2017-06-30 09:18:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-30 08:36:11
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Monterra Plan 1 Calculation Date/Time: 08:35, Fri, Jun 30, 2017
Calculation Description: Title 24 Analysis
Input File Name: Monterra-Plan 1-17.ribdl6x
CF1 R-PRF-01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2017-06-30 09:18:44
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, undethe laws of the State of California:
1. 1 am eligible under Division 3 of the Businessland Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system'desigri features identifed;:on'this'Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans endspecifications submitted�t tthe enforcemen a:g�ergcy for approval.with this�building permit application.
Responsible Designer Name: '
3k
Respon ,jble Designer SignatOpi
/GiYf/�Cd/
Tim Scott.. ': a �u_ �a<
Company: '•
h `
Dates Signed:
Scott Design and Title 24, Inc.
2017-06-30 09:18:44
Address:
License: -
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 217-P010127994G-000-000-0000000-0000 Registration DateMme: 2017-06-30 09:18:44
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695
Easy to Verify
at CaICERTS.com
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-30 08:36:11