Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2020-0003
78-495 CALLE TAMPICO D�tJ LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: SOLAR/RESIDENTIAL LESS THAN 1OKW Application Number: BSOL2020-0003 Property Address: 50485 VERANO DR APN: 777240012 Application Description: JACOBS / 8,000KW PV SYSTEM Property Zoning: Application Valuation: $17,600.00 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: MITCHELL & TRACI JACOBS 50485 VERANO DR LA QUINTA, CA 92253 Date: 3/4/2020 Applicant: Contractor: VIVINT SOLAR - ROXANNE CORONA VIVINT SOLAR DEVELOPER LLC DBA VIVINT 50 1111 E CITRUS ST UNIT 1 D a 1800 W ASHTON BLVD RIVERSIDE, CA 92507 LEHI, UT 84043-2019 MAR 0 4 2020 (801)845-0286 CITY OF lA QUINTA Llc. No.: 973756 ---------------------------- DESIGN &DEVELOPMENT'DEPARTREOI........................................ LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C46. C10, B. C39 License No.: Date: 03- U" • ?i) Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Addre! WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of trk for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: ZURICH AMERICAN INSURANCE CQbdE6NY Policy Number: WC509601305 _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date:®3 • ()y Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance ofthis permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above - mentioned property for inspection purposes. Dater3 04 20 Signature (Applicant or Agent): Date: 3/4/2020 Application Number: BSOL2020-0003 Property Address: 50485 VERANO DR APN: 777240012 Application Description: JACOBS / 8,000KW PV SYSTEM Property Zoning: Application Valuation: $17,600.00 Applicant: VIVINT SOLAR - ROXANNE CORONA 1111 E CITRUS ST UNIT 1 RIVERSIDE, CA 92507 Owner: MITCHELL & TRACI JACOBS 50485 VERANO DR LA QUINTA, CA 92253 Contractor: VIVINT SOLAR DEVELOPER LLC DBA VIVINT SO 1800 W ASHTON BLVD LEHI, UT 84043-2019 (801)845-0286 Llc. No.: 973756 Detail: 8.000kW DC / 7.227kW CEC AC SOLAR ARRAY - (25) HANWHA SOLAR 320W+SOLAREDGE P340 OPTIMIZERS W/ (1) SOLAREDGE SE7600H INVERTER [453SF] 2019 CALIFORNIA ELECTRICAL CODE. FINANCIAL INFORMATION DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT PV SYSTEM LESS THAN 10KW 101-0000-42403 0 $26.83 DESCRIPTION ACCOUNT CITY AMOUNT PV SYSTEM LESS THAN 10KW PC 101-0000-42600 0 $26.83 Total Paid for ELECTRICAL 2019: $53.66 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $101.97 Total Paid for PERMIT ISSUANCE: $101.97 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 tev Q"Kra - — GEM oftb, DESERT — PERMIT # PLAN LOCATION: 50485 V Project Address: LAAQ QUINTATA,, CA CA 92253-9011 Pro ect Descri tion: Pool Remodel Add't Elect Plumb Mech? � p ' APN #: 777240012 Residential Roof Mount Solar PV: 8.0(kW), 25(Modules), 1(inverter), No MPU Applicant Name: Roxanne Corona Address: 1111 E Citrus St, Unit 1 City, ST, Zip: Riverside CA, 92507 Telephone: 9 51 464-6047 Email: roxanne.corona@vivintsolar.com Valuation of Project $ 17,600 Contractor Name: Vivint Solar New SFD Construction: Address: 1800 W Ashton BLVD Conditioned Space SF City, St, Zip Lehi, UT, 84043 Garage SF Patio/Porch SF Telephone: (385) 429-7356 Email: riversidepermitteam@vivintsolar.com Fire Sprinklers SF State Lic: 973756 City Bus Lic: Arch/Eng Name: Construction Type: C-46 (solar) Occupancy: Address: Grading: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: Mitch Jacobs Address: 50485 VERANO DR City, ST, Zip LA QUINTA, CA 92253 Telephone: Email: New Commercial / Tenant Improvements: Total Building Construction Type: Occupancy: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 SF N The new Q.PEAK DUO DLK-1135 solar module from Q CELLS impresses with its outstanding visual appearance and particularly high performance on a small surface thanks to the innovative Q.ANTUM DUO Technology. Q.ANTUM's world -record -holding cell concept has now been combined with state-of-the-art circuitry half cells and a six-busbar design, thus achieving outstanding performance under real conditions — both with low -intensity solar radiation as well as on hot, clear summer days. Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY 'y Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.3%. f INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, QCELLS Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QTM. TOP WNPPV EXTREME WEATHER RATING 7�18 High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa) regarding IEC. opA RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year Quality Tested linear performance guarantee2. ;m ; �y STATE OF THE ART MODULE TECHNOLOGY ID. 40032587 Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. APT test conditions according to IEC/TS 62804-1:2015, method 8 (-1500V, 168h) 2 See data sheet on rear for further THE IDEAL SOLUTION FOR: information. Rooftop arrays on residential buildings Engineered in Germany OCELLS MECHANICAL SPECI I Format 66.3in x 39.4in x 1.26in (including frame) -� &5a•1999mm1 139•n995mm1 (1685mm x 1000mm x 32mm) ° 9.ww..99P.r.a,rr,9ar.a Weight 41.2 1 bs (18.7 kg) Front Cover 0.13 in (3.2 mm) thermally pre -stressed glass with anti -reflection technology � ^--- Back Cover Composite film Frame Black anodized aluminum ® "e•,l000mm, Cell 6 x 20 monocrystalline Q.ANTUM solar half -cells ❑ )unction box 2.76-3.35in x 1.97-2.76in x 0.51-0.83in (70-85mm x 50-70mm x 13-21mm), decentralized, IP67 Cable 4mm2 Solar cable; (+) Z43.3 in (1100mm), (-) t43.3in (1100mm) �' 9UM.A "•,",••• 39•,3:mm1 �- �jea35 i95m 9 Connector Multi -Contact MC4, IP68 9999.199.5m0I I ELECTRICAL CHARACTERISTICS POWER CLASS 300 305 310 315 320 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +5 W /-OW) Power At MPP' PMPP [W] 300 305 310 315 320 Short Circuit Current' Isc [A] 9.72 9.78 9.83 9.89 9.94 e Open Circuit Voltage' Voc IV] 39.48 39.75 40.02 40.29 40.56 E Current at MPP IMPP [A] 9.25 9.31 936 9.41 9.47 Voltage at MPP VMPP IV] 32.43 32.78 33.12 33.46 33.80 Efficiency' r1 [%] > 17.8 >_ 18.1 >_ 18.4 >_ 18.7 z 19.0 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Power at MPP PMPP [W] 224.1 227.8 231.6 235.3 239.1 E Short Circuit Current Iso [A] 7.83 7.88 7.92 7.97 8.01 e e Open Circuit Voltage VRc IV] 37.15 37.40 37.66 37.91 38.17 Current at MPP IMPP [A] 7.28 7.32 7.37 7.41 7.45 Voltage at MPP VMPP IV] 30.78 31.11 31.44 31.76 32.08 'Measurement tolerances PMPP t3%; I, Vox 5% at STC: 1000 WIW, 25±2°C, AM 1.5G according to IEC 60904-3 -'800 Wlm�, NMOT, spectrum AM 1.5G Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE 190 19 If 99 �n 10 P9zoi° I,s n wln Ine n 9nen mmul�io'�.a�iry �n mnpemses ePlemb,. 20inl YEARS At least 98 % of nominal power during first year. Thereafter max. 0.54 % degradation per year. At least 93.1 % of nominal power up to 10 years. too At least 85% of nominal power up to 25 years. All data within measurement tolerances. -- ---- ------ Full warranties in accordance with the warranty 5 terms of the Q CELLS sales organization of your respective country. 40 90 gee Poo moo IRRADIANCE IWAn'l Typical module performance under low irradiance conditions in comparison to STC conditions (25°C, 1000W/m2). TEMPERATURE COEFFICIENTS Temperature Coefficient of Isc a [%/Kl +0.04 Temperature Coefficient of V. P [%/K] -0.28 Temperature Coefficient of PMPP Y [%/K] -0.37 Normal Operating Module Temperature NMOT PF] 109 t5.4 (43 t3°C) PROPERTIES1 DESIGN Maximum System Voltage VSYs IV] 1000 (IEC) / 1000 (UL) Safety Class II Maximum Series Fuse Rating [A OC] 20 Fire Rating C (IEC) / TYPE 1 (UL) Max. Design Load, Push / Pull (UL)z [lbs/f[�l 75 (3600Pa) / 55 (2667 Pa) Permitted module temperature -40°F up to +1857 on continuous duty (-40°C up to +85°C) Max. Test Load, Push / Pull (UL)' [lbs/ft3] 113 (5400 Pa) / 84 (4000 Pa) Z see installation manual QUALIFICATIONS 1 CERTIFICATES PACKAGING INFORMATION UL 1703; VDE Quality Tested; CE-compliant; Number at MadWes per Pallet 32 IEC 61215:2016; IEC 61730:2016. Application class A Number of Pallets per 53' Trailer 30 Number of Pallets per 40' High Cube Container 26 1) E C Q SUS Pallet Dimensions (L x W x H) 69.3 in x 45.3 in x 46.9 in (1760mm x 1150mm x 1190mm) Pallet Weight 14151bs (642 kg) NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product, Hanwha 0 CELLS America Inc. 300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA I TEL+1 949 748 59 961 EMAIL inquiry®us.q-cells.com I WEB www.q-cells.us ROCK -IT SYSTeM 3.0 S9STem SPecIFIcaTIons Max No. of Panels 300 Modules per ground lug Materials 300 Series Stainless, 6000 Series Aluminum Max System Voltage 1000VDC Coating Black Andodization/Mill Finish Class A Fire Rating With UL1703 Type 1 Rated Lug Specifications Burndy CL50-1TN Ground Lug Modules (UL Listing #KDER E9999) Leveling Range 3-4" Ground Wire 14 AWG- 4 AWG Copper Per above Lug spec. Ground Wire Rock -It Slide Comp Range 3" Max Module Size 64.96"(1 650m m) x Rock -It Slide Tile 7" 39.05"(992mm) x 2"(50mm) Min/Max Roof Slope 1/2:12/12:12 Max Downforce/Uplift Rating 45 PSF Max Anchor Spacing (35mm/40mm) 72" Rock -It Mount Load Rating 547lbs with Single 5/16" Lag 3.0 Max Anchor Spacing (32mm) 48" Safety Factor Skirt Box QTY 6 units Slide Fastening Hole 5/16" diameter Mount Box QTY 12 units Module Cantilever Maximum cantilever is 1/3 Rock -It Slide Box QTY 50 units bracket spacing Coupling Box QTY 12 units Warranty 20 Year Material and Workman- ship Codes: National Electric Code, ANSI/NFPA 70, NEC 250, NEC 690, IRC, IBC Standards' UL 2703: First Edition, UL 1703 FeaTu res • New and improved design North -South adjustability • Fastest, easiest to level system on the market • Only one tool required (1/2" deep wellsocket) • Integrated electrical bonding • Vertical adjustment of Y-4" • SIMPLE- only 5 components www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 20 EVaLuaTeD, COmpaTIBLe MODI_.ILes Maduia Maeufa[Iwrer 11odwlemodel ('R w4d to Ir41cAta wad abl►teuI Moduk101mxnsWns �mtnj Module lSimenslons{ink b-watdProsrury T"t Wad [0q UpwardJrrrrs>rreTesr toad(prt) Do sdor.Yasl to4d(00 Maximum[lamySPArllyjlnf Porllall M.avimum0,"pSpHiAN1101 landuipe A01 ec Soler AC-x M/156.605 1640 x 992 x 40 64.57 x 39.06 x 1.57 45 M1 i 30 •78 72 Canadian Solar C56P-xxxM 1638 x 982 x40 64.50 x 38.70 x 1.57 SD s0 30 48 72 Canadian Solar C56P-)=P 1634 x 902. x 40 64.50x 38.70x 1.57 SO 50 30 46 72 Hanwha$ Q.PRO 8FR-G4 2" 1670 x 1000 x 32 65.70 x 39.40 x 1.26 45 45 45 _ 30 30 f 48 NIA 72 l00 48 Hanwha Q.PLUS 8FR-G4.12xx 1670 x 1000 x 32 65.70 x 39 40 x 116 45 45 30 46 12 100 45 30 A 48 Hanwha Q.PRO BFR-G4.12m 1670 x 1000 x 32 65.70 x 39.40 x 126 45 45 30 46 72 48 100 45 30 NJA Hanwha %PRO BFR-G4.3 Zia 1670 x 1000 x 32 65.70 x 39.40 x 1.26 45 45 30 48 72 200 45 30 N/A _ 48 Hanwha Q.PEAK-G4 12Kx 1670 x 3000 x 32 65 70 x 39.40 x 1.26 45 45 30 48 72 100 45 30 N/A 48 Hanwha 0.PEAK-G4.1jMA1f 2xx 1670 x 1000 x 32 65.70 x 39.40 x 1.26 4S 45 30 48 72 100 45 30 N/A 48 Hanwha Q.PEAK BLK G4.12xx 1670 x 3000 x 32 65.70 x 39.40 x 1.26 45 45 30 48 72 100 45 30 NIA 48 Hanwha Q.PRO 64 2xx 1670 x 1000 x 32 6S.70 x 39.40 x 1.26 45 45 30 48 72 100 45 30 NIA 48 Hanwha Q PLUS G4 2m 1670 x 1000 x 32 65.70 x 39.40 x 1-26 45 45 30 49 72 48 300 4$ 30 NIP, Ha mvha 0,PEAK-64.1/FAA 2xx 1670 x 10DO x 32 65.70 x 39.40 x 1.26 0 45 30 48 7.2 101) 45 30 W.A 48 Hanwha Q.PEAK BLK G41/TAA 2m 1670 x 1000 x 32 65.70 x 39 40 x 126 45 45 30 48 72 106 45 30 A 48 HAnwh► aPFAX DUO OLK•G5 1685a 10Mx 32 66-34x39-4Qx 125 48 46 N 48 72 1W AS 30 NVAL a Hanwha Q.PEAK DUO-G5 1685 x 1000 x 32 66.34 x 39.40 x 1.26 45 45 30 48 72 100 45 30 N/A 48 Hanwha Q.PLUS BFR 64.1/TAA In 1670 x 1000 x 32 65.70 x 39.40 x 1.26 45 45 1 48 72 100 45 30 N/A 4B Hanwha Q.PLUS BFR G4.1/MAX 2m 1670 x 1000 x 32 65 70 x 39 40 x 1.26 45 45 30 48 12 _ a8_ 100 45 30 N/A Hanwha 8-UNE PLUS 8FR 04.12M 1670 x 1000 x 32 65.70 x 39.40 x 1.26 45 45 30 44 72 100 45 30 N/A 48 Hanwha BANE PRO BFR G412n 1670 x 1000 x 32 65 70x 39.40 x 126 45 too 45 30 49 72 4S 30 N/A 48 Hanwha Q.PRO EC-64.4 2m 1670 x 1000 x 32 65.70 x 39.40 x 1.26 45 45 30 48 72 300 45 30 N/A 48 Itak IT-xxx-SE 1675 x 1001 x 40 65 94 x 37 41 x 1.57 45 45 30 48 72 Onk* lKMmP-60 1650x 992x40 69.00 x 39 OS x 1.57 45 45 30 .$a 72 Jlnko 1KM-M-60 1650 x 992 x 40 65.00 x 39.05 x 1.57 45 45 30 48 72 Anko JKMx1(KP-GM 2650x912x40 65.00A39,05-IV 45 45 30 4R 72 Anko JKMxmM-60B 1650 v 992 v 40 65-00 x 39 05 x 1.57 45 45 30 48 72 link* JKMMPP40 1650 x 992 x 40 65.00139.05 x 1.57 45 45 30 48 72 llnko JKM=MM-60 1650 x 992 x 40 65.00 x 39 05 x 157 45 45 30 48 72 Lwfi Solar LRe L,)- a Lew 091v40 65-00x 39.07x 1.57 45 45 30 48 72 LG Electronics 1,63DON 1C-R3 1640 x 1000 x 35 64.57 x 39.37 x 1.38 45 AS 30 48 48 LG Electronics LG300N1K- i4 1640 x 1000 x 40 0.57 x 39-37 x 1-W 45 4:5 JO 48 72 Lon Solar LR6-60BK-mM 1650 x 991 x 40 fi5.00 v 39.02 x 157 45 45 30 •78 72 Long[ Solo, LR6.60PB--M 1650 ■ 991 x 40 65.00 x 39.02 x 1.57 45 45 30 48 72 Lonlill Solar LR6-60PE-wM 1650 x 991 x 40 65.00 x 39.02 x 1.57 45 45 30 48 72 Long Solar LR6.60PH-)=M 1650 x 991 K 40 65.00 K 39.02 x 1.51 45 45 30 48 72 Mission MSExvvSQ5T 1664 .999.40 65-Sl K 39.33 x 1.57 45 45 JO 48 72 Mission MSE=M5K 1664 x 999 x 40 65.51 x 39.33 x 1.57 A 5 4S 30 43 72 Mission MSExxx5Q5T 1664 x 999 x 40 65.51 x 39.33 x 1.57 45 45 30 _ 30 48 _ 72- 48 100 45 N/A Mission MSEMD=T 1664 x 999 x 40 65.51 x 39.33 x L57 45 45 30 A8 12 too 4S 30 N/JL 48 panasonic VSHNxxxSA17 1590 x 1053 x 35 1 62.60 x 41.50 x 1.40 45 45 30 48 72 REC Solar REO=TP2 BLK 1675 x 997 x 3a 6S.90 x 3125 x L • 50 30 30 30 48 72 RECSolar RECxXXTP2 BLK 1675,997v38 6590 x 3925 x S SO 45 45 30 48 48 RFCSolar RECmTP2 1675 x 997 x 38 65.90 x 39.25 x 1.50 45 45 30 48 48 RECOM RCM-2u-6MB 1640 x 992 x 35 64.60 x 39.00 x 138 45 45 30 48 46 $IReO $LA2551) 1650 x 990 x 38 64-96 x 38.99 x 1-50 45 45 30 46 72 Solaria PowerXT -R-8X 1621 x 1056 x 40 63 82 x 4157 x 1.57 45 45 30 48 72 SolarWorld SW PL J4a MONO BK 2575 x 1001 x 33 6SAS x "ADx L30 36 30 30 48 72 SolorWorld SW Pl. xxx MONO BK 1675.x JOOJ x 33 65.95 x 39.40x 3-30 45 45 30 48 48 Sunprem a GxR-SOOT 1670 x 997 x 40 65.75 x 39.25 x 1.57 45 4S 10 48 72 Trine Solar TSM-- PXOS 08 1640 x 992 x 40 64.57 x 39.06 x 1-57 so 50 30 48 72 Trim Solar TSM-xxxPA05.o5 1650 x 992 x 35 64.9S x 39.05 x 1.37 45 45 3o 48 N/A 72 48 100 45 30 Ylnyll Solar YL2.P-29b 1650 x 990 K 40 65.00x 38.98 v 1-57 45 45 30 414 72 Ha nwna O•Ln11f 12nira mdulrs to OC usoa wIID Spe[lal Orner KOCK-It System components Lall for mT6115 a ° 4 EenFasten a�D (ID Solar www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 21 Cut Sheet - Rock -it 3.0 Coupling 1. Installation to be completed in accordance with manufacturer's written specifications and installation instructions. 2. See spec sheet or contact manufacturer for detailed material, finishes, and configuration options. 3. Contact manufacturer for detailed layout. 4. Do not scale drawings. 5. Subject to change without notice. 3.60in [91.51 m m] 2.41 in [61.12mm] . I-EcoFasten Solar` Toll Free Phone 1.877.859.3947 4741 W Polk St. Ste. 4 Fax 602.272.4668 Phoenix, AZ 85043 7.00in [177.80mm] Rock -It 3.0 Coupling Cut Sheet Material: 6000 Series Aluminum Scale: 1:1 8/21 /2018 Cut Sheet - Rock -it 3.0 Mount 1. Installation to be completed in accordance with manufacturer's written specifications and installation instructions. 2. See spec sheet or contact manufacturer for detailed material, finishes, and configuration options. 3. Contact manufacturer for detailed layout. 4. Do not scale drawings. 5. Subject to change without notice. 3.60in [91.51 mm] 4.91 in [124.75mm] FcoFasten Solar-.s. Toll Free Phone 1.877.859.3947 4741 W Polk St. Ste. 4 Fax 602.272.4668 Phoenix, AZ 85043 2.53in [64.14mm] Rock -It 3.0 Mount Cut Sheet Material: 6000 Series Aluminum Scale: 1:1 8/21 /2018 Cut Sheet - 1. Installation to be completed in accordance with manufacturer's written specifications and installation instructions. 2. See spec sheet or contact manufacturer for detailed material, finishes, and configuration options. 3. Contact manufacturer for detailed layout. 4. Do not scale drawings. 5. Subject to change without notice. '� LPIIVE �..4 SN[ tiYJARDS `` Morlasten Solar"289 Harrel Street Morrisville, VT 05661 Toll Free Phone 1.888.766.4273 Toll Free Phone 1.877.859.3947 Material: See Spec Sheet Toll Free Fax 1.888.766.9994 Toll Free Fax 1.888.766.9994 Scale: 1:1 8/3/2017 ,q$Ci: - EF$: - Cut Sheet - ROCK -IT SLIDECOMP V2 1. Installation to be completed in accordance with manufacturer's written specifications and installation instructions. 2. See spec sheet or contact manufacturer for detailed material, finishes, and configuration options. 3. Contact manufacturer for detailed layout. 4. Do not scale drawings. 5. Subject to change without notice. 2.50in [ 63.50mm ] 1 .75in [ 44.45mm ] I 2.00in [50.65mm]� V LPINE ®a°` I ;cof' stenSolar° NO GUARDS 4.00in [ 101.60mm] 289 Harrel Street Morrisville, VT 05661 Toll Free Phone 1.888.766.4273 Toll Free Phone 1.877.859.3947 Material: See Spec Sheet Toll Free Fax 1.888.766.9994 Toll Free Fax 1.888.766.9994 Scale: 1:2 12/6/2016 ASG: - EFS: X Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US / SE1000OH-US /SE1140OH-US a a solar 3 t�i-_-F'1�3wnw 0 a i Optimized installation with HD -Wave technology / Specifically designed to work with / UL1741 SA certified, for CPUC Rule 21 grid compliance power optimizers / Record -breaking efficiency / Extremely small / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Fixed voltage inverter for longer strings / Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 solaredge.com / Built-in module -level monitoring / Outdoor and indoor installation / Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) solar=sv Single Phase Inverter Wit HID -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US APPLICABLE TO INVERTERS V117H PART NUMBER OUTPUT SEXXXXH-XXXXXBs, - Rated AC Power Output 3000 3800 @ 2-10V 5000 5000 @ 240V 7500 0000 11400 @ 240V VA 3300, @ 208V 50u0 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 2dOV 7600 000C 11100 @ 240V VA 1x00 @ 208V 5000 Cti 208v1 10000 @ 208V AC Output Voltage M n,-Norn.411ax. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (2-i I - NO - 264) AC Output Voltage Min, -Nam. -Max ✓ _ ✓ ✓ Vac (183 - 208 - 2-19) AC Frequency (,Nominal` 59 3 60 - 60 5 " MdXImUm COrAIMIMI5 Output 12 5 16 21 25 32 42 47 D A Current @240V Maximum ContinuouS Output 6 2A 48,5 A Cwrent @208V/ Pewee Factor 1, adlustable -0.85 to 0.85 GEDI Threshold 4 A Utility Monitoring, Islandino Protection, Country Conngurable Yes Thresholds INPUT Maximum DC Powre! @2,10V 460 5900 7750 9300 1800 i5500 17650 1:11 Maxinwm DC Powei WMV - 5100 7750 550- W ],ansformer--less, Ungrounded Yes Maxim;:m Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Curren- @24CV 8 5 105 35 6.5 20 27 30.5 Adc Maximum Input Current @208V - 9 13 5 - - 27 Ad Max Input Short Circuit Clu rent 45 Adc Reverse-Polau,cy Protection Yes Ground -mule Isolation Detection 6001L,z Sersltiv(ty Maximum Inverter Effidencv 99 99.2 CEC We: hted Eficier- g qg 99 @ 2V 20 98 5 @ 208V Nighttime Power CauGmption 2 5 W For crher ,egE:nal set nog plaa,e SclarEdge s„pp,t A `:icYrr canenr snvr_c m,v be used: the in•r^rtri ndl lime rtc cuucnl [o tl;e !al,c> zataca Single Phase Inverter wit HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US Model Number SE3000H-US SE380OH-US SE5000H-US SE6000H-US SE760OH-US SE10000H-US SE1140OH-US ADDITIONAL Supported Communication Interfaces RS485, Ethernet, _7igBee (optional), Cellular (optional) Revenue Glade Data, ANSI C1220 Optional" Inve,ter Commissioning with the SetApp mobile application using built-in Wi-Fi Access Point for local connection Rapid Shutdown - INK 2014 and 2017 690.12 Automatic�.vn Rapid Shutdoupon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL16996, CSA C22 2, Canadian AFCI accoicling to T.I.L, b1-07 Gild Connection Standards IFFE1547, Rule 21, Rule'14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Canduit Size / AWG Range ' Maximum / 14-6 AWG 1" Maximum /14-4 AWG DC Input Concluit Size / # of Strings / AWG Reinige 'I" Maximum / 1-2 strings j 14-6 AWG I" Maximum /1-3 strings ;` 14-6 AWG Dimensions with Safety Switch (HxWxD) 17 7 x 14.6 x 6 8 ;' d50 x 370 x 174 213 x 14.6 x 7.3 1540 x 370 x 185 in / mm Weight with Safety Switch 221 10 25 1 % 11.4 26 2 i i1 9 3U /'17,6 Ih / Kg Noise : 25 <50 d9A Cooling Natural Convection Operating Temperature Ranqe -40 to +140 / -40 to +60'r' T /'C Plotectioit Rating NEMA 4X (Inverter willT Safety Switch) Revenue grade inverter P/N SExxxxH-L'S000BNC4 Full power cp to at least 5C'C / L_'F; for power de -rating mfonnanon reter T...: htgls'/Avwvrsolaredge,mm/sites!defaulVnles/se-temperat; e-derating-not2-na pdP J SoiarEdge Technologies. Inc. All rights reserved. SOLAREDGE, the Sol arEdge logo, OPTIMIZED BY SOLAR EDGE are trademarks or registered hademarks of Solar Edge Technologies, Inc All RQ� other trademarion ks mented herein are trademarks of their respective owners. Date: 5/2019N01/ENG NAM. Subject to change without notice Power Optirnizer For North America P320 P34Q V P370 / P400 / P405 / P505 25 'fFAR WARRANTY 1 PV power optimization at the module -level / Specifically designed to work with SolarEdge inverters / Up to 2S% more energy / Superior efficiency (99.5%) / Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading / Flexible system design for maximum space utilization r� J_C / Fast installation with a single bolt ! Next generation maintenance with module - level monitoring / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) / Module -level voltage shutdown for installer and firefighter safety solaredge.com solar=se / Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 INPUT WledLr1n11In. �'wrcr :J:1 " -- -,40 Abwlu[Lr mairm m, Irp A Wf t.xp F A (Vn[ A, k,w" t@mp6yAlaM; M0.drnur. 9lttrt rc u i Curran ^� — 11 (1K) _ M ;I[1,9urr or Ininft Canunl Mnxnmf r ETd[,@f1�1 4:h W RI W( vs • $7 Ikk 14 Ark ! Ark Vtgi ftYS ElMluiky 98,8 93"o M Owt vr*AjrC 01 , ❑ry p OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) tvld�,riu�r Cluhi'. ii gun e+'t t, Ikk Ifvlaarr:rr i)ulcul Vrylt.�cc _ _ _ � _ _ �� qlr OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OM SatM flulput Wuhage Ix+r p(m e.r f7wurer STANDARD COMPLIANCE EAdi P:I' E,-i'; r 1ac•, 6, !fi �li;nii_1-._i, IFi Oslo:": i Shlill� fECi�L IU 9-1 pins, II safety), UL1741 I A11>Scr.11 UL'1� `i-0, U'v' Rcsis[ont INSTALLATION SPECIFICATIONS :.j 4+ai drl': di a Itj Iq I I� 5 VI�rr lwc f1lk w,a,' c •'i � - woo we aaunl,. :p�polAfl@ Nuts l@I S ; dl iLawr (dye S�f l�.N 'rx1t 155 x:i]�i_I rti•"1 =;� 1LC Rtni il,res I'f,S:{- I r T7' FLy RJe1,3.Sj5 1�9•ii•].d1751 f "RI k,7.591 [ljfirLk1y11]f+f; (VI xLrFl; ,mn/ii, �,IxGx 1.] ]ixG.3xl9 51,�[.M1x�.; IAIi ' 1! lnr r,plvgj ",st+'••ti} 75iI 1 17 8r5 7 t.l 1tl[yi ! �..1 � ;11+ MCA 1 quR _nro c[x:r SuI.Jk. ur I1.. 0 MCM• irµuit Wire La•r Ib n A Ovqu'irfvive lypi•I(.muleclor OLAPA Wim Lwyll 1;Zfig mr'l �QlrQ:II1�TLYl,171�f y=lafp •i / •r pfi w!hl•, Retawe Ipumk% % ri7frl I•xr.� d II•. i •h�ln ,�1 i1L.W.A •Ia-.t.•u U••ry•!r'.rn^"Rn4a Fryu: ItC �S Y.W!i r.', �, ..• .. . , r , r .., , . i •Myrnl W, , [w..,ynn ,. •ir rF• I v -.l• im �.: Ih a, n.1V Fm uInNI Ll:&Ififl, ra'.•: rJ:.ry c:a•:.l:r'[I:vf:1pL• Ia Gun}'.�4py� I inxxl tp} a5! IFr raiyl Ir II'� Il.,• CI rr 'rar yMRIM 1-41 .. ;•n,+rr dr •,Wnf r u;rJ. J pe6 x1 V.... ,- U, 070, P4 0 M.,dnWn5nllYa icllyll, fIi l I� — �a 3I00 [�ii10J vptii mall m'n pcvkr per 3lfllxr r 11sl Param Struxl, n[ *�IflerrAt I rnfllFLx .F. Clrie" IaI4 i yf•.• r.;f Pr11MICnnrf rTrYl 11f01m7h'n-.'r-iv �Iry+r7Mr,L<dam•7r�•• l•Trufn RM n �frrkt. ni,rn rnnq I.+ I Wf II n IaA;.wn1 In itv 114 KA15RS even Pl[l+fi•1d11,^iN+R+t(47.n�Iiv %1 miri ' Avrr.frotlrrn rrll.,�• N,vla�•'�'n••'i.+.iys ri r p I'lrf •,y. 1 q. dl'0 •rr 'IvA MINinq G1 '.INWy r"I•r.lw .. v,l n•I ur •v rr iC' IeaWKLIi J93 itn,ri,'veV'v A I MI..V 1,• 6VAW P" Jwrsa-�•n i.1•.•14 ut.vi. x.�+I ,.I,.. r.I . , , +, a.. •, o i - 'I [! 41iy. l Ah'r I'p ir�l ririnr�.F\A'll!+ 131Nm•ICd Lmwl:i!f' 11 W �jun:l} 1, pp) Fa 1,u]LYL =ni{iplC4i'y;l fS 111Aft1{rISI[Iq.',F',JtlslR lr n.w..rNri lu R'Y�.`r•r. [Su�le. h` 1•r •n. L.•-: I, .r i .i..,ir..1L••. ryvtr• ,:+r •.,.,-�-••I,. ..+b.ur. ., n„li ., ,NI[, when t,T mNFMirrl xmcN .funs okelheb wit IFp mI r ltrL % (, in . n67L! 6 wuf6Cp -mmoif el l a +u r.ylh r.1.1•W v „l w tnc Ifw Yd.ilrkr k'99 dr1H@[611 �YssxNl6cer aI. h.dnnrrl.alry,LLv�u.1lfl"wl, d :,w Lraye• 1ftlirpt.+pin [R [� rn Ro H S Aft nih . v wk.n,axmnl4AKN1 bw.n,N usk•uWrri:. i or ur+ r.xl.I Wn n;Nr. WWIWAwM46 RAN S i;7"I rn <rr,r.yr.Iplrk -RIW Intertek sole ~ .. I III II II II II III-GOt6e��IIlI1I�II�IIII�I Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) This document describes how to install the rapid shutdown kit in the SolarEdge Safety Switch, and how to enable the rapid shutdown feature in the inverter in order to provide the functionality described in the Rapid Shutdown clause of NEC2014 690.12 (1) through (4). Kit Contents ' Rapid shutdown cables ' Micro -SD card and SD card adapter with firmware files (Note: DO NOT THROW AWAY THE CARD AND THE ADAPTER; keep them for installation of other rapid shutdown kits) Cable installation Perform this procedure before connecting the strings to the Safety Switch [Chapter 4: Connecting the AC and the Strings to the Safety Switch in the SolarEdge Installation Guide]. 1 Turn the inverter ON/OFF switch to OFF. If installing the kit in an inverter that is already operating, wait until the LCD indicates that the DC voltage is safe (<50V), or wait five minutes before continuing to the next step. 2 TurntheSafety Switch and the AC switch on the main circuit board to OFF. i If you cannot see the Inverter panel, or if a malfunction is indicated on the LCD panel, wait five minutes for the input capacitors of the inverter to discharge. 3 Loosen the four Allen screws on the front cover of the Safety Switch, and open the cover. 4 Carefully disconnect the two DC cables from the left side of the switch and from the DC connection spring clamp terminals, as illustrated below'. Use a standard straight -bladed screwdriver to disconnect the cables from the terminals. ` 3 Switch terminal block Disconnect here ! 9QT r!I ■ IN P.L. DC connection terminals Disconnect her *; i Al TR ' 0 V p Figure 1: Inside the AC/DC Safety Switch 1 The internal components may vary depending on the Safety Switch model; the figures in this documents show the AC/DC Safety Switch for single phase 7.6-11.4 kW inverters. Rapid Shutdown Kit Installation - MAN-01-00186-1.6 E solar - ■ • = Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) 5 The rapid shutdown cables have a resistor connected to one end (on the red cable). Connect these ends to the switch, making sure that the red and black cables are reversed relative to the cables connected at the top of the switch (going into the DC side conduit between the inverter and the Safety Switch), as detailed below. Apply a torque of 2 N*m (18 Ib*in): If the cables at the top are red and black from left to right, connect as shown below. Red (+) Black (-) Black (-) Red (+) with rapid shutdown resistor Figure 2: Rapid shutdown cable connected — option 1 If the cables at the top are black and red from left to right, connect as shown below. Black(-) Red (+) Red (+) with rapid Black (-) shutdown resistor Figure 3: Rapid shutdown cable connected — option 2 6 Use a standard straight -bladed screwdriver to connect the other end of the rapid shutdown cables to the DC connection spring -clamp terminals: Connect the black cable from the switch to the DC- terminal block, and connect the red cable from the switch to the DC+ terminal block. 7 Check that the cables are located and connected in the correct positions to ensure the rapid shutdown functionality. 8 Close the cover: Attach the switch cover and secure it by tightening the four screws with a torque of 0.9 ft.*Ib / 1.2 N*m. Rapid Shutdown Kit Installation - MAN-01-00186-1.6 ff solar = e • = Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) Inverter Software Compatibility Check and Upgrade Perform this procedure after activating the inverter [Step 1 in Chapter 5: Commissioning the Installation of the SolarEdge Installation Guide], and before pairing (Step 2 in Chapter 5 of the SolarEdge Installation Guide). To use the rapid shutdown feature, the inverter communication board firmware (CPU) must be: • Version 2.0700 or higher, if the CPU version is 2.Oxxx ■ Version 3.0700 or higher, if the CPU version is 3.Oxxx ► To check the inverter CPU version: 7 Verify that the inverter has been activated using the activation card supplied with the inverter. 2 Press the LCD light button short presses until the screen below is reached. I D : # # # # # # # # # # D S P 1/ 2: x. x x x x/ x. x x x x C P U 0 0 0 2. 0 7.0 0 C o u n t r y: X X X X X a�F 3 Check the CPU version number. If lower than 2.0700, upgrade the inverter software as described below; otherwise proceed to "Power Optimizer Pairing". ► To upgrade the inverter software: Use the supplied SD card adapter or the micro -SD card, which can be removed from the adapter, according to the activation card slot on your inverter communication board, labeled ®. 7 Verity that the AC breaker connected to the inverter is OFF. 2 Open the inverter cover's six Allen screws and carefully pull the cover horizontally before lowering it, as described in its manual. 3 Insert the card into the card slot on the communication board. If the communication board has an SD card slot, use the supplied SD card adapter. If there is a micro -SD card slot, remove the micro -SD card from the adaptor and insert it. 4 Close the inverter cover and turn the AC on. If upgrade is required (as described above), it starts automatically. 5 Wait for the message "Done" to be displayed on the LCD. 6 Verify the correct version as described above. 7 Remove the card from the inverter and keep it for additional kit installations. Power Optimizer Pairing Pairing at this stage will reprogram the power optimizers to perform rapid shutdown. 1 Verify that the ON/OFF switch at the bottom of the inverter is OFF. 2 Turn ON the AC breaker and the Safety Switch. 3 Perform Pairing as described in Step 2: Pairing, of Chapter 5: Commissioning of the SolarEdge Installation Guide. Enabling Rapid Shutdown There is an option in setup mode to enable the functionality of rapid shutdown. 1 Verify that the ON/OFF switch at the bottom of the inverter is ON. 2 Enter Setup mode by pressing and holding the LCD light button. 3 Select Maintenance + Optimizer Conf. 4 Set Rapid Shutdown. • Whenever replacing, removing or adding a component in the string, perform Pairing and rapid shutdown setting. Troubleshooting If the inverter does not enter production mode and the LCD displays Night Mode, the connection order of the rapid shutdown cables may be incorrect. Recheck the cables and make sure that the rapid shutdown cables connected to the bottom of the switch are reversed relative to the cables connected at the top of the switch (see Figure 2 and Figure 3). Rapid Shutdown Kit Installation - MAN-01-00186-1.6 ff Intertek Total Quality. Aawred. Address: Intertek 3933 US 11 Cortland NY 13045 Telephone: 607-758-6516 www.intertek.com Subject: ETL Evaluation of SolarEdge Products to NEC 2017 Rapid Shutdown Requirements To, whom it may concern This letter represents the testing results of the below listed products to the requirements contained in the following standards: National Electric Code, 2017, Section 690.12 requirement for rapid shutdown. UL 1741, UL 1741 CRD for rapid shutdown The evaluation was done on the PV Rapid Shutdown System (PVRSS), and covers installations consisting of optimizers and inverters with part numbers listed below. The testing done has verified that controlled conductors are limited to: Not more than 30 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation outside the array. Not more than 80 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation inside the array. The rapid shutdown initiation is performed by either disconnecting the AC feed to the inverter, or — if the inverter DC Safety switch is readily accessible — by turning off the DC Safety switch. Applicable products: ■ Power optimizers: o PBxxx-yyy-zzzz; where xxx is any number, 0-9, up to a maximum value where xxx = 350; yyy could be ACB or TFI; and zzzz is any combination of four letters and numbers. o OP-XXX-LV, OP-XXX-MV, OP-XXX-IV, OP-XXX-EV; where xxx is any number, 0-9. o Pxxx; where xxx is any number, 0-9 to a maximum up to 500. • 1-ph Inverters: o SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE1000OA-US / SE1140OA-US / SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US when the following label is labeled on the side of the inverter: This information is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense, or damage occasioned by the use of this information. Any observations and results in this report are relevant only to the sample evaluated. Only the Client is authorized to copy and distribute this information and only then in its entirety. © 2017 Intertek Version: 8-September-2016 Page 1 of 2 GFT-OP-10a intertek Total Quality, Assured, OTOVOLTAIC RAPID UTDOWN SYSTEM Inverter part number may be followed by a suffix Address: Intertek 3933 US 11 Cortland NY 13045 Telephone: 607-758-6516 www.intertek.com • 3-ph Inverters: o SE9KUS / SEIOKUS / SE14.4KUS / SE20KUS / SE30KUS / SE33.3KUS ; when the following label is labeled on the side of the inverter: VC "a LTAIC RAPID UTDOWN SYSTEM Inverter part number may be followed by a suffix If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the undersigned. Please note, this Letter Report does not represent authorization for the use of any Intertek certification marks. Reviewed by: Howard Liu Title: Engineering Team Leader Signature 64�� Date: 4/6/2017 This information is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense, or damage occasioned by the use of this information. Any observations and results in this report are relevant only to the sample evaluated. Only the Client is authorized to copy and distribute this information and only then in its entirety. © 2017 Intertek Version: 8-September-2016 Page 2 of 2 GFT-OP-10a vivint.Solar Sentinel is a communications gateway intended to improve PV systems communication for new installs and retrofits. It connects to inverters & batteries via Ethernet, communicates with the customer's home router via WiFi and switches to cellular if connectivity is lost. At- 'I—, •,— -- t Scenario Benefits ■ No need for WiFi, PLC or Zigbee in inverter • if connection to the customer's home WiFi router drops, Sentinel maintains contact with the Vivint Solar cloud via cellular ■ If customer changes their WiFi router hardware or settings, Sentinel can be accessed remotely over cellular to reconfigure access to home WE • Universal comnis solution accross all inverter manufacturers Communication Pathway Sentinel Installed equipment (inverter, battery, consumption meter, etc.) # - - W-iSi - Home ethernetEShBBt `� �� router r RS48^r,4851 Cellular B adba c•n��� Fm�der VeMbF d 1 / MvW1Polled data Inverter initiated IP data Copyright © 2017 Vivint Solar, Inc. All Rights Reserved. Schneider 10, Field -Installed Mains Kits jr.' t f , ; c t r i c Class 1170 / Refer to Catalog I OOCTO501 s chne Ide r-electric.us HomelineTM Load Centers Rainproof, 10, Main Lugs and Main Circuit Breakers 103W-120/240 Vac—UL Listed Table 1.40: Convertible Main Load Centers (Accepts Only HOM Plug -On Circuit Breakers.) Main Luga 10 kA Short Ghouls Current RafJnp Fact❑ry-rnslulled Fixed Main Lugs, tO kASho t Circuil Current Rating rr.q ! 2 I 4 ! 2 I II0iU4l.l0Ei6 14-4 F'K•: C;I{;•1 1R R - PK7TA 2 125A I 4 ' 8 4 I HOM4P.L1 I 12•-210 t4-2f0 PK7GTAIrwAN d Convertible Mains with Factory-Enstall-tl Mal Lugs! 12'. QOASI Ma in Framo Sfxo- ConverBWe it Breaker (Sse 8 16 8 HOM816L125PRB jI PK9GTA 125A 12 24 12 HOM12241_125PRB P-210 fi-1 I PK"GTA 20 40 20 HOM204OL125PRB PK18GTA 24 4B HJut244fk43;rPR9 11 �'h23G fA convatibfa Mafnavrlth Factory -installed Main Lugs 1121. OOM2 Main Fra i1aSi 4 6raakRr {SnA j' 12 12 0 HOM12L225PRB PK9GTA 16 32 16 HOM1632L225PRB PKI5GTA 225 A 20 40 20 HOM204OL225PRB ,_= 4-250 PK18GTA 30 60 30 HOM306OL225PRB PK23GTA 40 80 40 HOM408OL225PRB PK27GTA 42 8.1 42 HOM42E4L225PRB PK27GTA Main Circult Breaker---22 IkA Short Qrcull Currenl Ra11,nt� CorlverlNo Mains Fnctory•Inetsllod Main Circuit B[eakor, ODMI Mom F1pma.5 Matn Li vnlh 8 16 a . r•IOM616M100PRB 100A 12 24 72 H0M1224M100PRB 20 4 20 HOM2040MIDOPRB B 16 11 HOMa1GM125PRO R 125A 2e 48 Id,HOM244OM125PRB A ComrerflbIa Mnfns u11h FacfotyInslaAcd Main Ciruilt Breaker; 3]OM2 _ _ In L N 150 A 30 I 60 30 HDM30fi0M150P tB P 12 12 0 HOM12M200PR13 R 20 40 20 HOM204OM200PRB O O 200 A 30 60 3D HOM306OM200PRB F 40 60 40 lSU1'IL 3.': r.1: UUPF26 Convertible Mains with Factory-Inst RW� Main Ci.'eaH "att erw!Ih Feed-IriN tut QOM2 M.In Frame Sit >—Cunvddrbla to Maki Lugs or Lower Amperegri MWn =9 Breaker (See 8aiow) F!?[ rS,QA I a j`ifi a 1 rlr�esdhl_,w frt1� ,BMt0:s{ 200A 8 I 78 $ HOMa1lrl 0PF1Ra Above lialtngs through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. 0 kill' OOL125 :Y*V,i . - I QOL225 or LawarAmperage Mein Ckcuit Brrraker ($oe.Belowl PK9GTA 6-2/0 I 6-1 PKI5GTA _ PK18 TA 6-2/0 6-1 1 PK9G'rA PK23GTA Or Lower Amperage Main 3R 3R 4R 6k 5R BR 6R 711 14R 14R ,p lvT 3R 3R 4R 3R BR PK9GTA 511 t 2'0 PKiBGTA 6R PK23GTA 7R PK27GTA I 14R 10, Field -Installed Mains Kits Table 1.41: For Convertible Load Centers Only MainTypc Main 4ugs f f61 Frame S�za _ Mere Ratin Rating 125 A 100-125 A 001-125 225 A 150-225A 001.225 6-210 At or Cu 6-300A1 or Cu 50 A 100-125 A OOM50VH 60 A 100-125 A OOM60VH 70 A 100-125 A QOM70VH OOM1 BOA 100-125 A OOM8OVH 12-2/0 At or Cu 90 A 100-125 A QOM90VH 100A 100-125A QOM100VH Main Circuit 110 A 125 A QOM110VH Breaker[13] 125A 125A QOM125VH 100 A 150-225 A OOM2100VH 125 A 150-225 A QOM2125VH OOM2 (17] 150 A 150-225 A QOM2150VH 4-300 AI or Cu 175 A 200-225 A QOM2175VH 200 A 200-225 A OOM2200VH 225A 225A OOM2225VH [8] Maximum single pole branch circuits utilizing HOM and/or HOMTcircuit breakers [9] See Rainproof, Dimensions, Knockouts and Boll -on Hubs, page 1-24 [10] HOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire. (111 70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker. [12] Side hinge door device allow 1-1/4 In. on left side for door to open. [13] 22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. [14] Do not exceed the lead center mains rating. 115] Wire range listed for main device kits is the wire range of that device. To find out maximum wire size permitted in a particular load center per UL, see tables in QOT- Load Centers, page 1-3 and QOTM and HomelineTM Load Centers and Circuit Breakers, page 1-15 under Main Wire Size [16] If main circuit breaker knockout has been removed from the load center's trim, order appropriate filler plate from DO and Homeline Load Center Accessories, page 1-16. [17] Add suffix 1021 for 120, 208, 240 Vac shunt trip. © 2017 Schneider Electric 1-19 All Rights Reserved 2/15/2017 Homeline"m Circuit Breakers 111 121 131 141 151 1.20 �I I HOM 1 P HOM 2P 1 Space Required 2 Spaces Required i1 HOM220OBB Branch Circuit Breaker 4 Spaces Required HOM 1PCAFI HOM IPCAFI Plug -on Neutral Pigtail 14 ' [Art 1 HOM 1P DF HOM 1P DF Plug -on Neutral Pigtail Plug -On Circuit Breakers Class 1170 / Refer to Catalog 110OCT0501 by Schneider Electric schneider-electric.us Homeline Plug -On Circuit Breakers The Square D Homeline circuit breakers are in a 1 in. wide format for 1-pole circuit breakers. They are designed to plug into Homeline load centers. Table 1.42: HOM • � V.. Coninion Trip t 15 A 10 kA HOM115 ,112) HOM215 20A 10 kA HOM120 1 21 HOM220 7 25 A 10 kA HOM125 f21 HOM225 2 30 A 10 kA HOM130 /21 HOM230 1 35A 10 kA HOM235121 40 A 10 kA HOM140 121 HOM240 f21 45 A 10 kA HOM245IZ 50A 10kA HOM150121 HOM2501d GOA 10 kA HOM260(21 70 A 10 kA HOM270 121 60 A 10 kA HOM280 90A 10 kA HOM290 100 A 10 kA ROW = Y 110A 10kA — HOM2110 121 125 A 10 kA HOM2125 12 150 A 10 kA HOM2150e8 t?1LIJ 175A 10 kA HOM2175BB12131 200A 10 kA HOM220OBB 1293 Homeline High Magnetic (HM) Circuit Breakers High magnetic trip circuit breakers are recommended for applications where high initial inrush current may occur. Table 1.43: HOM-HM s5A 20 A Homeline Combination Arc Fault Circuit Interruptors (HOM-CAFI) Homeline Combination Arc Fault Circuit Interrupters —Provide overload and short circuit protection, plus arc fault protection in accordance with the NEC and U1-1699. Table 1.44: HOM-CAFI One -Pale Combination Arc -Fault Circuit 15A 1 ipr)h:110:r11.,:. Interrupter with Pigtail Neutral 20A 1 HOM120CAFI+•I,' Plug -On Neutral Combination 15 A 1 HOM115PCAFI !•:' _ Arc -Fault Interrupter 20A 1 Twa•Pofe Combination Arc -Fault Circuit 15 A 2 HOM215CAFI (41 t51 Interrupter with Pigtail Neutral 20A 2 HOM220CAF1141151 Homeline Dual Function Circuit Breaker (HOM-DF) Homeline Combination Arc Fault and Ground Fault Circuit Interrupters (Dual Function) — Provide overload and short circuit protection, plus arc fault and ground fault protection in a single device in accordance with the NEC, UL1699 and UL943. Table 1.45: H0111 Circuit Breaker Type Poles Combination Arc -Fault and Ground Fault Circuit Interrupter with Pigtail Neutral 15A i 1 HOM115DF 41 20 A 1 HOM120DF f41 Plug -On Neutral Combination Aro-Faull and Ground Fault ClrcWt Interrupter 15A 1 H0M115PDF141 20A 1 HOM120PDF 141 UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment haing motor group combinations and marked for use with HACR type circuit breakers. Requires four spaces (1 AWG-300 kcmil AI/Cu) Use only in 10 panel rated 150 A or greater. UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment haing motor group combinations and marked for use with HACR type circuit breakers. For 120/240 V only, not for 208Y/120 V. 02017 Schneider Electric All Rights Reserved 2/15/2017 by Schneider Electric sc hnelder-electric.us HOM 1P GFI (With Ground Fault Circuit Interrupter) 1 Space Required Plug -On Circuit Breakers Class 1170 1 Refer to Catalog 1100CT0501 HOM 2P GFI (With Ground Fault Circuit Interrupter) 2 Spaces Required HOMT Quad Circuit Breaker 2 Spaces Required HomelineTM Circuit Breakers Homeline GFI (HOM-GFI) HOM-GFI circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 milliamperes or more. Table 1.46: HOM-GFI Homeline Equipment Protection Device (HOM-EPD) Homeline Equipment Protection Device —Circuit Breakers with 30 mA Equipment Ground Fault Protection (UL Listed). Table 1.47: HOM-EPD-10 k AIR HOMT Tandem and HOMT Quad Tandem Circuit Breakers Table 1.48: HOMT Tandem Circuit Breakers 15 and 15 A 10 kA HOMT 1515 7" 15 and 20 A 10 kA HOMT1520 r 20 and 20 A 10 kA HOMT2020 7) 30 and 15 A 10 kA HOMT3015171 30 and 20 A 10 kA HOMT3020 j71 Table 1.49: HOMT Quad Tandem Circuit Breakers (2) M A 15 A 1 10 kA Tandem-1201240 Vac JTwo Spaces HOMT1515215 ij t21 15 A 20 A 10 kA HOMT1515220 (2)15A 25A 10 kA HOMT1515225 (21 15 A 30 A 10 kA HOMT1515230 (2) 15 A 40 A 10 kA HOMT151524017 (2) 15 A 50 A 10 kA HOMT1515250 (2) 20 A 20 A 10 kA HOMT2020220 (21 20 A 25 A 10 kA HOMT2020225 1 (2) 20 A 30 A 10 kA HOMT2020M 17 (2) 20 A 40 A 10 kA HOMT2020240 71 (2) 20 A 50 A 10 kA HOMT2020250171 NOTE: Typical catalog number (e.g. HOMT 1515230) represents two 1 P, outer poles (two 15 A 1 P CBS) and one 2P inner circuit breaker with common trip (one 30 A 2P CB). Homeline Circuit Breaker Wire Sizes Table 1.50: Circuit Breaker Wire Sizes Breaker Type HOM 1P 15-30 A 14-8 AWG 14-0 AWG or (2) 14-10 AWG 40-50 A 8-2 AWG 8-2 AWG 2P 2P 15-30 A 14-8 AWG 14-8 AWG or (21 14-10 AWG 70 A 8-2 AWG 8-2 AWG 80-125A 4-2/OAWG 4- 150-200 A 4 A C-300 kcmil 4 A 300 kcMil HOMT arid Quad 15-30A 14-8AWG14-8 AWG Quad Only 40-50 A I B-12 AWG 6-14 AWG HOM-GFI - I A 1a10AWG 14-10AWG H M- Fl-2P I1 A 1 12-4AW 1 [6] 15-20 A tandem or quad tandem circuit breakers are suitable for use with 60oC or 75eC conductors 25-50 A tandem or quad tandem circuit breakers are suitable for use with 75eC conductors only [71 UL Listed as HACR type for use with air conditioning, healing and refrigeration equipment haing motor group combinations and marked for use with HACR type circuit breakers (81 15-30 A circuit breakers are suitable for use with 60oC or 75cC conductors. 40-125 A circuit breakers are suitable for use with 75-C conductors © 2017 Schneider Electric 1-21 All Rights Reserved 2/15/2017