Loading...
Santerra TR 32225 (Plans 1A, 3B & 4A) Title 24Certificate Of Compliance : Residential (Part 1 Of 4) CF-1 R ._S.anter_ra-P_lan-A__.-_____----------------------..------_._ 1.2/_712QQ9_ Project Title Dates. -La_Quinta__----------- Project Address Building Permit # -Gal lant_Et;.e.r_Consulti.ng__ - _____- 760 743-5408 plan Check/Date - Documentation Au or Telephone -n.e.r_ vvPro __ CA Clfmate_Zor1e--15 Field Check/Date Complirice Method Climate Zone - - TDV Standard Proposed Compliance JkBtu/srZ_ - __Design Design _ Margin Space Heating 1.92 1.50 0.42 Space Cooling 65.97 58.06 7.90 Fans 9.38 9.16 0.22 Domestic Hot Water 10.58 13.72 -3.14 0.00 0.23 -0.23 Totals 87.84 82.68'. 5.17 Percent better than Standard: 5.9% Building Type: [j] Single Family ❑ Addition Total Conditioned Floor Area: 2,351 ft2 0 Multi Family u Existing + AddiAlt Existing Floor Area: n/a ft2 Building Front Orientation: (W) 270 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 2,351 ft2 Fenestration: Average Ceiling Height: 10.0 ft Area: 464 ft2 Avg. U: 0.39 Number of Dwelling Units: 1.00 Ratio: 19.7% Avg. SHGC: 0.37 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name _ Floor Area Volume Units _ Zone Type Type_ Hgt. Area F_AU1-.LIVING ____-_ - _ 1 1,389 3,890 -0-59- -Conditioned-_ .onditioned__ Setback____ --_2_-.___n/a _FAU2_SLEEP_ING..__ -. _ _ ___962 -9,620 -0.41- Conditioned- -_Setback___. __.._ 2 Na OPAQUE SURFACES Insulation Act. Type -- ---- Frame ----------- - Area ------- U-Fac. ----- Cay. Cont. Azm. - Tilt -- Wall_ ._ Wood-__. ____. 456_ _0.074_ -R-1.9_ __RRO_0_ 270__-90 .Door ------ None_ _.__ 2.4_. 0 500_ -None _i-0...0 27.0_-___94 .Door,---- None__ .- _10_ ___0.500_ ._.-lone _-.R-0.O_ 2.7.0_ 90 -.all_..--- Wood_- .-____65_ -0_074_ __8_-19_ __R-0_0------ 0__.-_-90 Wall-- _ .Wood-__ -_320_ -0-074 ___RA_9 _t-O.Q 90 9 Wall__-- Wood _...._ -- 420_ -0._074_ R-1.9 _R_00- - _480_-__90 .Roof-.___ Wood_.--_ 1,389 _-0_025_ -R-.38_-R-0.0_--270__0 Wall-- Wood_. __ _.._ 162_ -0.074_ -R_i9_ _-R=0.0- 270_-_90 Wall----- Wood-_..__ .-______472 __0-074 __R-19. --R-O 0 0_-----94 Wall___ Wood_____ ____._13.7_. __0..074_ __B_-1.9..___R-0_0 9.0--__30 Mall--__ Wood____-. __-200_ -0.0.7_4- _-R-1.9_ _8m0_0_ _ 180_.__-_90 .Roof-.._. Wood_____ __-962_ __0.025_ __R_38_ _R__0.0_ 170_____.-0 - EnergyPro 4.4 by EnergySoft Gains Condition Y / N Status JA IV Reference Location / Comments [X IX❑New IX IX ",X IX IX IX IX El EJNew____ ❑ ILI CNew- [JNew__ ❑New DNew E-New O' l New _0.9�95 ____ EAU_i._LI_V_ING._. _ _28_-94__ _-- FAU_t1l_ViNG 28_A4--___ ______ FAU1_1-IVING _.__ New _09-_A5_ -___ .FAUIIIVl G_. ___- Ne,% _ 09_-A5 -_. F-AU1_LI_V1N_ .G_-- 09-A5 FAW_LIVING_-_--___-_-_-_- 09_-A5_- --_-_ FA1.12SLEEP_ING___-_-----___--- 08_A5-__---- FAU2_SLEEP_,NSA--__--._..--------_._. _09-A5 ___- -EAU2_SLEEPING-----------_-------__-- New _09-A5--__.__ .FAU2S1EEP_lNG_-___ evv 01-_]. _-__.---.EAU2_S1_EE°ING_________._____.._-.. _A_s._-_-_..-- BttlOM-- SA_Fl1YD P__T--== _-- _. 8-CDN-ST_R-UC_TION- - ---- nitiation Time: 12/07/0910:49:21 Run C User Number: 2875 Job Number: Page: 1 of 10 Certificate Of Compliance :Residential (Part 2 of 4) CF-1 R Santerra Plan 1 A _ _ 12/7/2009 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGCz Azm. Tilt Stat. Glazing Type Comments 1 -Window _Front (W)_ 14.0 _4.55D_116-A_0-67 1_1_6-B _2Z0_ -9.0_ New Double Non Metal Clear FAW LIVING 2 Window Front (W) 4.0 0.390 NFRC 0_36 NFRC 270 90 New NonMetalLowE FAU1 LIVING 3 Window Front (W) 4.0 0.390 NFRC 0_36 NFRC 270 90 New NonMetalLowE FAU1 LIVING 4 Window Front (W)_ 16.0 0.390 NFRC 0_36 NFRC 270 90 New NonMetalLowE FAW LIVING 5 Window Front JW) 12.0 0.390 NFRC 0.36 NFRC 270 90 New NonMetalLowE FAW LIVING 6 Window Left (N) 25.0 0.390 NFRC 0_36 NFRC 0 90 New NonMetalLowE FAW LIVING Z Window Rear (E) 48.0 0.39 NFRC0.36 NFRC 90 90 New NonMetalLowE FAW LIVING 8 Window Rear (E) 10.0 0.390 NFRC 0_36 NFRC 90 90 New NonMetalLowE FAW LIVING 9_ Window Rear (E) 24.0 0.390_NFRC 0.3_6 NFRC 90 90 New NonMetalLowE FAW LIVING 14 Window Rear (E) 64.0 _ .399 NFRC 0.36 NFRC 90 90 New NonMetalLowE FAW LIVING 11 Window Rear (E_ 24.0 0.390 NFRC 0_36 NFRC 90 90 New NonMetalLowE FAU1 LIVING 12 Window Rear (E)_ 12.5 0.390 NFRC 0.36 NFRC 90 90 New NonMetalLowE FAU1 LIVING 13 �(1Lindow Rearr F)_ 12.5 _0..39 NF_BC.-O3.6 NFRC 90 _AkN.ew NonMetalLowE FAW LIVING 14 Window Rear (E) 25.0 0.390 NFRC 0_36 NFRC 90 90 New NonMetalLowE FAW LIVING 15 Window Front (W) 15.0 0.390 NFRC 0_36 NFRC 270 90 New NonMetalLowE FAU2 SLEEPING 16 Window Front (W) 15.0 0.390 NFRC 0_36 NFRC 270 90 New NonMetalLowE FAIJ2 SLEEPING 17 Window Front (W) 8.0 0.390 NFRC 0_36 NFRC 270 90 New NonMetalLowE FAU2 SLEEPING 18 Window Left (M_ 8.0 0.390 NFRC 0_36 NFRC 0 90 New NonMetalLowE FAU2 SLEEPING AR Window Left (N) _25.0 0.399 NFRC 0.36 _NFRC 0 90 New NonMetalLowE FAU2 SLEEPING 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 _ -- 5 Bug Screen 0.76 _ 6 Bug Screen 0.76 5.0 5.0 44.0 0.5 10.0 10.0 Bug Screen 0.76 8 Bug Screen 0.76 5.0 2.0 6.0 0.5 6.0 6.0 9 Bug Screen _ 0.76 6.0 _ 4.0 8.0 0.5 8.0 8.0 10 Bug Screen 0.76 8.0 8.0 8.0 0.5 8.0 8.0 11 Bug Screen 0.76 6.0 4.0 8.0 0.5 8.0 8.0 12 Bug Screen 0.76 13 Bug Screen _ 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen _ 0.76 18 Bug Screen 0.76 19 Bug Screen _ 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R-Val. JA IV Reference _ Status Comments PERIMETER LOSSES Insulation Condition Location/ Tvoe Lenath R-Val. Location JA IV Reference Status Comments Slab Perimeter 162 None No Insulation 26-Ai New FAW LIVING Slab Perimeter 113 None No Insulation 26-Ai New FAU2 SLEEPING 4.4 User Number: 2875 Job Number: 2 of 1 Certificate Of Compliance : Residential (Part 2 of 4) CF-1 R Santerra Plan 1 A 12/7/2009 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type Comments .20_ Window I aft (N) 19 S --O.M0 _NFRC AIM -NFRC 0 __9 - New NonMetalLowE -FAU9 RLEPPING 21 Window Left (N) 12.5 0.390 NFRC 0.36 NFRC 0 90 New NonMetalLowE FAU2 SLEEPING 22 Window Rear AE) 48.0 0.390 NFRC 0_36 NFRC 90 90 New NonMetalLowE FAU2 SLEEPING 23 Window Rear (E) 12.5 0.390 NFRC 0.36 NFRC 90 90 New NonMetalLowE FAU2 SLEEPING 24 Window Rear (E) 12.5 0.390 NFRC 0_36 NFRC 90 90 New NonMetalLowE FAU2 SLEEPING 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen 076 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location! Type (sf) (in.) Cap. Cond. R-Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ TvDe Lenath R-Val. Location JA IV Reference Status Comments EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: Page:3 of 10 1 Certificate Of Compliance : Residential (Part 3 of 4) CF-1 R Santerra Plan 1 A 12/7/2009 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type FAU1 LIVING Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback _ FAU2 SLEEPING Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Location Duct Coolina Location FAUi LIVING Ducted Ducted Attic FAU2 SLEEPING Ducted Ducted Attic Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R-Value Status Tested? 6.0 New Yes 6.0 New . Yes WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R-Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. _ Rheem 22VR75-70N FHR=109 Small Gas Recirclrime+Temp 1 70,000 75 New 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation CONTRACTORS ARE RESPONSIBLE FOR THE FINAL SIZING OF HEATING, COOLING AND DHW EUUIPMEN 1. ((:EC blueprint #bu) COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overail design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: SkyEConstruction Address: 2240 Encinitas Blvd Ste D485 Encinitas R 920 _ Telep�ioQe./160-594 2 Lic. #: (signditl'r6 `" v U ' (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Mark Gallant, CEPE Title/Firm: Gallant Energy Consulting Address: 508 W Mission Avenue, Suite 201 Escondido. CA 92025 Telephone: �760 743-5408 _ 'I } 12/7/09 ----_J (date) C l/T-�r llliT--..--�! Ladd, n. to -Rion 0 Buildinq E,,crgy i r:n>id6 rq:- Mark Gallant ROH-02.222 of 10 Certificate Of Compliance :Residential (Part 4 of 4) CF-1 R Santerra Plan 1 A 12/7/2009 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aaencv determines the adeguacv of the iustification, and may reiect a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. Plan I The Roof "R-38 Roof Attic + rb" includes a Radiant Barrier. I I I HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a mt:Kb proviaer using approvea testing ana/or venfication metnoos. Plan Field The HVAC System "FAW LIVING' incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. The HVAC System "FAW LIVING' incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "GMS80704/GSC13048/CP48A2B" includes credit for a 11.0 EER Condenser. The HVAC System "FAU2 SLEEPING' incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. The HVAC System "FAU2 SLEEPING' incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. _ The Cooling System "GMS80453/GSC13036/CP36A2B" includes credit for a 11.0 EER Condenser. i I EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: Paae:5 of 10 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF-1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (*) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N!A DESIGNER ENFORCE - MENT Building Envelope Measures *§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U-factor in metal frame ceiling. ❑ N ❑ § 150(b): Loose fill insulation manufacturer's labeled R-Value: ❑ ❑ ❑ *§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). *§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ N ❑ b. outside air intake with damper and control, flue damper and control ❑ N ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑x ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(I): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3 % , water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ a ❑ CF-6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Eafiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U-Factor, certified Solar Heat Gain ID ❑ El (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ El § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ IN 1 nI ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ IX ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ 1] ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R-value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑x ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ 1XI ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ 0 and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: Page:6 of 10 Mandatory Measures Summary: Residential (Page 2 of 2) MF-1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A If not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CIVIC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ © ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑X ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑X ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ rEX] ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ a ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency.Regulations, on -off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ U ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ Fx] ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (1): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l : HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ R ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑x ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X El OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ftj OR are controlled by a dimmer switch OR are controlled ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that dbes not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: _ Page:7 of 10� Residential Kitchen Lighting Worksheet WS-5R Santerra Plan 1 A 12/7/2009 Project Title Date At least 50% of the total rated wattage of permanently Installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts CAN Yes X1 No 26.0 x _ 11 = 286 or undercab 32w Yes X1 No 1 1 32.0 x 6 = 192 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes I No I L x = or Yes I No 11 x = or Yes I No I L x = or Yes No x = _ or _ Yes No x = or -- Yes No x = or Yes No x — = or Yes No _ x = or _ Yes No x = or _ Yes No x = or Yes No _ x = or Yes No x = or Yes No x = or Yes No x = or Total A: 478 B: 0 COMPLIES IF A z B YES R NO ❑ EnergyPro 4.4 by Energysoft User Number: 2875 Job Number: _ Page_8 of 10 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Santerra Plan 1 A 12/7/2009 SYSTEM NAME FLOOR AREA FAW LIVING 1,389 GAI(�INFFRIAR: r 4;:rwcz GvgTFM 1 nen Number of Systems 1 Heating System Output per System 56,000 Total Output (Btuh) 56,000 Output (Btuh/sqft) 40.3 Cooling System Output per System 47,000 Total Output (Btuh) 47,000 Total Output (Tons) 3.9 Total Output (Btuh/sqft) 33.8 Total Output (sgft/Ton) 354.6 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sqft) 1.15 Airflow (cfm/Ton) 408.5 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 OF Outside Air 0 cfm 69.0 of 111.0 / 77.6 of Outside Air 0 cfm 79.1 / 65.1 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,064 20,272 11757 627 20,668 0 1,841 1,646 0 0 0 0 0 0 0 0 0 1,841 1,646 23,954 1,757 23,960 GMS8 /00 47 47 GSC13048/CP48A2B 34,157 7,956 56,000 Total Adjusted System Output 3a,157 7 5 56,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 a ni 69.0OF 69.0OF 101.90F Supply Fan Heating Coil 1600 cfm Return Air Ducts 79.1 / 65.1 of 79.1 / 65.2 of 59.0 / 57.9 of Supply Fan 1600 cfm Supply Air Ducts 101.0 of ROOMS 70.0 of Supply Air Ducts' Cooling Coil 60.1 / 58.3 of 49.5% R.H. ROOMS 78.0 / 64.8 of Return Air Ducts EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: _ Page:9 of 10 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Santerra Plan 1 A 12/7/2009 SYSTEM NAME FLOOR AREA FAU2 SLEEPING 962 ENGINEERING CHECKS ISYSTEM LOAD Number of Systems 1 Heating System Output per System 36,000 Total Output (Btuh) 36,000 Output (Btuh/sgft) 37.4 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 Total Output (Btuh/sqft) 36.4 Total Output (sgft/Ton) 329.8 Air S +stem CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sqft) 1.25 Airflow (cfm/Ton) 411.4 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 ote: values above given at ARI conditions :ATING SYSTEM PSYCHROMETRICS 26.0OF 69.2OF 69.2OF Outside Air 0 cfm 69.2 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 764 13,228 1,463 477 13,466 0 1,201 1,072 0 0 0 0 0 0 0 0 0 1,201 1,072 15,630 1 463 15,611 GMS80453/GSC13036/CP36A2B 23,186 8,723 36,000 Total Adjusted System Output 23,186 8,723 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am Supply Fan Heating Coil 1200 cfm 97.3 of Return Air Ducts Supply Air Ducts 96.5 of ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6OF 78.9/66.2OF 78.9/66.3OF 60.8/59.7OF Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 61.7 / 60.1 of 1200 cfm 53.2% R.H. ROOM 78.9/66.20F 78.0/65.9OF Return Air Ducts EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: Page:10 of 10 1 Certificate Of Compliance : Residential (Part 1 of 4) CF-1R _Santerra PJati3B 12/7/2009 Project Title I a Qi junta -_ _ Date Project Address Building Permit # GaLLatlt_Et1e inn_ (760 743-5408 Plan Check/Date Documentation Au o� Telephone Fnernv ro CA Climate Zone 15 Field Check/Date CompliWrfce Method Climate Zone TDV Standard Proposed Compliance _(kBtu/sf- r) Design Design Margin Space Heating 1.48 0.94 0.55 Space Cooling 58.28 52.44 5.85 Fans 8.27 8.24 0.03 Domestic Hot Water 8.99 11.72 -2.74 Pumps 0.00 0.19 -0.19 Totals 77.02 73.53 3.49 Building Type: [jd Single Family ❑ Multi Family Building Front Orientation: Fuel Type: ❑ Addition ❑ Existing + Add/Alt (W) 270 deg. Natural Gas Total Conditioned Floor Area Existing Floor Area: Raised Floor Area: Slab on Grade Area: Fenestration: Average Ceiling Height: Area: 472 ft2 Avg. U: 0.40 Number of Dwelling Units: Ratio: 16.5% Avg. SHGC: 0.38 Number of Stories: BUILDING ZONE INFORMATION # of Thermostat Zone Name _ _ Floor Area Volume Units Zone Type Type _F-AW-L1VING 1,294 laaznazn �45_ Confinflonpd Sethark _EAU2SLEEPWG 1.562 15,620 -0.55_ conditioned _ gethack OPAQUE SURFACES Insulation Act. Type Frame Area U-Fac. Cay. Cont. Azm. Tilt Wall_ Wood 256 _0 074_-R-1.9_ R-0_0_ ___2Z0_ 90 _I2oor - None 24 _0,500_ Mope_ _R-0.0_ _- 27.0_ 9.0 Dons None 22 _0.500_ None _R-0_0_ -270 9Q Wall- Wood- _____43E _0_0Z4 R-19 R-n_0 0_ 9Q Wall- Wood 184 0-074 R_19 R-0.090 90 Wall_ Wood__ 45 _0_n4_ _EL-1_9_ _R-0.0_ ---1-8.0_ 9f) Roo.L_ Wood- 1,294_ 0 025_ -38_ R-0.0_ 270 _0 Wall- Wood- 30_ _0.07A- J3-1.9_ _I3.0.0_ 270 _ 90 Wall- Wood- 310 0-074 R19 B-0..0_ 0_ 90 Wall -Wood- __168 0.074_ R-1.9 _R-0.0_ -9.0-_90 Wall- Wood- 563- _0_OZ4 R-I9_ _13-0-0_ 1.81 90 _Roof- Wnod__ _1,562 _0 0 5_ R-38 _R-0 0_ 271L__ 0 2,856 ft2 n/a ft2 0 ft2 2,856 ft2 10.0 ft 1.00 Vent Hgt. Area 2 __n/a -2 /a Gains Condition Y / N Status JA IV Reference Location / Comments IX El New 09-A5 EAt11 11I IVING IX A❑NPW El El ❑New New- 28-A4 EAU_LLIVING_- New-_ 28- 4 FAW LIVING MA5 FA 11 ING IV 09-A5 EAULLLVING- IX El ❑New New- 09-A5 FAW LIVING 01-Ais FAU1 LIVING ® ® ❑New ❑New 09-A5 FAU2 Sl FFPING 09-A5 FAU2 SLEEPING Q% ❑New 09-A5 FAU2 SLEEPING X X ❑New ❑New Il9-A.5 FAII SLEEPING 01-Al_8 EA1 19SI FEPING Run Initiation Time: 12/07/09 10:50:53 Run Code: 1260211853 I EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: _ Paget of 8 _ J Certificate Of Comaliance : Residential (Part 2 of 4) CF-1 R Santerra Plan 3B 12/7/2009 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Tvoe Area U-Factorl SHGCZ Azm. Tilt Stat. Glazinq Twe Comments 1- 2 Wlndow__Front-n- 26_0_ M50 11.6-A _0.6-7 116- Window Front (W) 12.0 0.390 NFRC 0.36 NFRC 9Z0_ 90_ New-_Dauhle Non Metal Clear 270 90 New NonMetalLowE At 11_1 IV_IL1G FAU1 LIVING 3 Window Left (N)_ 16.0 0.390 NFRC 0.36 NFRC 0 90 New NonMetalLowE FAU1 LIVING 4 Window Left (N)_ 4.0 0.390 NFRC 0.36 NFRC 0 90 New NonMetalLowE FAU1 LIVING 5 Window Left (N) 4.0 0.390 NFRC 0.36 NFRC _ 0 90 New NonMetalLowE FAU1 LIVING 6 Window Rear (E) 20.0 0.390 NFRC 0.36 NFRC 90 90 New NonMetalLowE FAU1 LIVING _7 Window Rear (E)- 30.0 0.390_NFRC 0.36 NFRC 90 90 New NonMetalLowE FAW LIVING 8 Window Rear (E) 20.0 0.390 NFRC 0.36 NFRC 90 90 New NonMetalLowE FAU1 LIVING 5 Window Rear (E) _ 21.0 0.390_d.FR)z0.36 NFRC_90 90 New NonMetalLowE FAU1 LIVING 10- Window Rear (E)_ 64.0 0.390 NFRC 0_36 NFRC 90_ 90 New NonMetalLowE FAU1 LIVING 11 Window Rear (E) 21.0 0.390 NFRC 0.36 NFRC 90 90 New NonMetalLowE FAU1 LIVING 12 Window Right (S) 25.0 0.390 NFRC 0.36 NFRC 180 90 New NonMetalLowE FAU1 LIVING _ 13_ 14 Window Window Front_(WL Rear (E) 40.0 72.0 0.390_N.F1RD-.36 _NFRC 0.390 NFRC 0.36 NFRC _27_0 90 New NonMetalLowE 90 90 New NonMetalLowE -EAU2 SLEEPING FAU2 SLEEPING 15 Window Right (S)_ _ 15.0 0.390 NFRC 0.36 NFRC 180 90 New NonMetalLowE FAU2 SLEEPING 16 Window Right (S) 15.0 0.390 NFRC 0.36 NFRC 180 90 New NonMetalLowE FAU2 SLEEPING 17 18 Window Window Right Right (S) (S) 25.0 6.0 0.390 NFRC 0.36 NFRC: 0.390 NFRC 0_36 NFRC 180 . 90 New NonMetalLowE 180 90 New NonMetalLowE FAU2 SLEEPING FAU2 SLEEPING 19 Window Right (S) 30.0 0.390 NFRC -OM NERO 180 90 New NonMetalLowE FAU2 SLEEPING 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bucl Screen 0.76 6 Bug Screen 0.76 _ 7 Bug Screen _ 0.76 8 Buq Screen 0.76 9 Bug Screen 0.76 7.0 3.0 9.5 2.0 8.0 8.0 10 Bug Screen 0.76 8.0 8.0 9.5 2.0 8.0 8.0 11 Bug Screen 0.76 7.0 3.0 9.5 2.0 8.0 8.0 12 Bug Screen 0.76 5.0 5.0 44.0 2.0 10.0 10.0 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 T 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R-Val. JA IV Reference Status Comments PERIMETER LOSSES Type Length Insulation R-Val. Location JA IV Reference Condition Status Location/ Comments Slab Perimeter 143 None No Insulation 26-A1 New FAU1 LIVING Slab Perimeter 151 None No Insulation 26-A1 New FAU2 SLEEPING EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: -- Page:2 of 8 - Certificate Of Compliance : Residential (Part 2 of 4) CF-1 R Santerra Plan 3B _ 12/7/2009 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments 20. Winddow--M t (S) 8._0- —0 39.ONEF C AM NF_RG _180_ —9Q New- NonMetalLowE FAI 12 S PINS`, 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Te SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 20 BugScreen creen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R-Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ TvDe Lenath R-Val. Location JA IV Reference Status Comments EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: Page:3 of 8 1 Certificate Of Compliance : Residential (Part 3 of 4) CF-1 R Santerra Plan 3B _ 12/7/2009 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type FAU1 LIVING Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback FAU2 SLEEPING Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Location Duct Duct Condition Ducts Location R-Value Status Tested? FAU1 LIVING Ducted Ducted Attic 6.0 New Yes FAU2 SLEEPING Ducted Ducted Attic 6.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R-Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Rheem 22VR75-70N FHR=109 Small Gas Recirc/Time+Temp 1 70,000 75 New 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation HEATING, COOLING AND DHW EQUIPMENT. (CEC Blueprint #60) COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comp:y with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: SkyEConstruction Address: 2240 Encinitas Blvd Ste D485 ncinitas, 92024/ TeleDhond/J,90-594-2 82 Lic. #: (signaturd) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) Documentation Author Name: Mark Gallant. CEPE Title/Firm: Gallant Energy Consulting Address: 508 W Mission Avenue, Suite 201 Escondido, CA 92025 Telephone: (760) 743-5408 12/7/09 (date) CABEC [allo'ni;i Buildinq Encrcry nnsulhints Marty Gallant RDA-02-222 Certificate Of Compliance :Residential (Part 4 of 4) CF-1R Santerra Plan 3B 12/7/2009 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The Roof "R-38 Roof Attic + rb" includes a Radiant Barrier. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved iesung andror venncauon memods. Plan Field The HVAC System "FAU1 LIVING' incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. The HVAC System "FAU1 LIVING' incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "GMS80704/GSC13048/CP48A2B" includes credit for a 11.0 EER Condenser. The HVAC System "FAU2 SLEEPING' incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. The HVAC System "FAU2 SLEEPING' incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "GMS80905/GSC13060/CP60B2X" includes credit for a 11.0 EER Condenser. ri n— l 1 1 L rt n L YI I EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: Page:5 of & Residential Kitchen Lighting Worksheet WS-5R Santerra Plan 3B 12/7/2009 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? WattsQuantity Watts Other Watts CAN Yes X1 No 1 1 26.0 x 8 = 208 or undercab 32w _ Yes X1 No 1 1 32.0 x 5 = 160 or Yes No x = or _ Yes No x = or Yes No x = or Yes No x = or _ Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or _ Yes No x = or Yes No I x = or Yes No x = or _ Yes No x = or Yes No x = or Yes No x = or — Yes I No _ x = or Yes No x = or Total A: 368 B: 0 COMPLIES IF A z B YES [X] NO ❑ EnergyPro 4.4 by EnergySoft User Number: 287.5 Job Number: Page:6 of 8 J 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Santerra Plan 3B 12/7/2009 SYSTEM NAME FLOOR AREA FAW LIVING 1,294 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 56,000 Total Output (Btuh) 56,000 Output (Btuh/sgft) 43.3 Cooling System Output per System 47,000 Total Output (Btuh) 47,000 Total Output (Tons) 3.9 Total Output (Btuh/sgft) 36.3 Total Output (sgft/Ton) 330.4 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) 1.24 Airflow (cfm/Ton) 408.5 Outside Air (%) Outside Air (cfm/sgft) 0.0 0.00 ote: values above given at ARI conditions :ATING SYSTEM PSYCHROMETRICS 26.0 OF 69.1 OF 69.1 OF Outside Air 0 cfm 69.1 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I I COIL HTG. PEAK CFM Sensiblel Latent CFM I Sensible' 951 18,328 1,69 554 18,377 0 1,664 1,464 0 0 0 0 0 0 0 0 0 1,664 1,464 21,656 1,691 21,305 GMS80704/GSC13048/CP48A2B 34,152 7,893 56,000 Total Adjusted System Output 34,152 7,893 56,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK = Aug 2 pm Jan 12 am 102.0 of Supply Fan Heating Coil 1600 cfm Return Air Ducts Supply Air Ducts 101.2OF ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6OF 79.0/65.0OF 79.0/65.1OF 58.9/57.8OF Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 59.9 / 58.1 of 1600 cfm 49.3% R.H. ROOMS 79.0 i 65.0 of 78.0 / 64.7 OF Return Air Ducts EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: Page:7 of 8 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Santerra Plan 3B 12/7/2009 SYSTEM NAME FLOOR AREA FAU2 SLEEPING 1,562 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 72,000 Total Output (Btuh) 72,000 Output (Btuh/sqft) 46.1 Cooling System Output per System 58,500 Total Output (Btuh) 58,500 Total Output (Tons) 4.9 Total Output (Btuh/sqft) 37.5 Total Output (sgft/Ton) 320.4 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sqft) 1.28 Airflow (cfm/Ton) 410.3 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 942 16,541 1,876 542 18,704 0 1,502 1,490 0 0 0 0 01 F 0 0 0 0 1,502 1,490 19,545 1,876 21,683 GMS80905/GSC13060/CP60B2X 38,131 15,076 72,000 Total Adjusted System Output 38,131 15,076 72,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 ami EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0OF 69.3OF 69.3OF 103.10F Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 102.4 of 2000 cfm ROOMS 70.0 of 69.3 of Return Air Ducts 111.0/77.6OF 78.7/66.1OF 78.7/66.1OF 60.8/59.8OF Outside Air 0 cfm Supply Fan Cooling Coil 2000 cfm 78.7/66.10F Supply Air Ducts 61.5 / 60.0 of 53.0% R.H. ROOMS 78.0/65.8OF Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: Page:8 of 8 Certificate Of Compliance : Residential (Part 1 of 4) CF-1 R Santerra Plan 4A Project Title Let-Qui.nta Date Project Address Building Permit # -Gall l0 __ (760) 743-5408 Plan Check/Date Documentation Au or Telephone -En er 0 CA Climate Zone 15 Field Check/Date Comp ce Method Climate Zone TDV Standard Proposed Compliance _(kBtu/sf- r) Design Design Margin Space Heating 2.53 2.26 0.28 Space Cooling 65.76 59.78 5.98 Fans 9.33 9.39 -0.06 Domestic Hot Water 7.97 10.39 -2.43 Pumps 0.00 0.17 -0.17 Totals 85.59 81.98 3.61 Percent better than Standard: 4.2% Building Type: n Single Family ❑ Addition ❑ Multi Family ❑ Existing + Add/Alt Building Front Orientation: (E) 90 deg Fuel Type: Natural Gas Fenestration: Area: 735 ft 2 Avg. U: 0.40 Ratio: 22.8% Avg. SHGC: 0.37 BUILDING ZONE INFORMATION Zone Name Floor Area Volume Total Conditioned Floor Area: 3,222 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 3,222 ft2 Average Ceiling Height: 10.0 ft Number of Dwelling Units: 1.00 Number of Stories: 1 # of Units EAW11V_ING 135n35n 13,500 -0.42_ EAU2-SLEEPING 1.549 15"490 0-48_ .EAU3_CASITA 323 3,230 0.10 OPAQUE SURFACES Insulation Act. Type Frame Area U-Fac. Cay. Cont. Azm. Tilt Wall_ Wood- 312 0 074 .__R-i9_ _R_0.0_ 9.0_9.0 Door__ None- 24 _0.50D None_ -FL-Q.Q_ 90 9 _Door done_- 10_ _0.5o0 None_ _R-0.0_ 9.0_.An Wall- Wood 387 _0-074_ -R19_ R 0 0 isn 9.Q WAIL- Wood- 190 0.074 -R_-1R _R-0.0_ PM 9 Wall__ Wood_ 103 _0.074_-R-1.9_ _R-0..00 9 Roof- Wood- 1.35n_350 _0,095_ R-38 R-0.0_ 970_ 0 Wall- Wood- 983_ 0 074 R-19 _R-0.0_ 90_ 9 Wall- Wood- 226 0-07_4 R-1.9_ RAD i.8Q 9 Wall_ Wood 300 _0_074_ _R-1.9_ R-4.0 -270_ 90 Wall_ Wood- . 51 - _0..074_ R-19- R-0.0_ 0_--9Q _Roof- Wood- 1 _-54.9_-0_025_ -EL--38_ _R-0-.0_ 97.0_ 0 Wall_ Wood- 240 0.074 R-1_9R-0.0_ _9.0_ _90 Wall_ Wood_ 150 _Q_07_4_ _R-19_ _R-0_0_ 18.0_ 90 Wall- Wood- 228 0.074 R-19 R-Q._ 970 90 _Door None- 10 0_900 done_ R-0_0_ 970_ 90 Wall- Wood- 150_ 0 0.74 __13-19_ R-n.Q _�99 .Roof- Wood- -323_-0..025_ --EL38- _R-0.0_ 27.0_ 0 Zone Type Conditioned Conditioned ConditiQnesl Thermostat Type -Setback- -Setback Setback Vent Hgt. Area -n/a n/a 2 _nLa Gains Condition Y / N Status JA IV Reference Location / Comments New 09-A5 - EAW-LIVING New 28-A4 FALA LIVING New 28-A4 EAW-LIVING New 09-A5 FA 1_ 11 1 IVING New 09-A5 FAL11_IIVING New 09-A5 EAU1 LLV_ING New 01-Aig EAU1__LIVING New 09-A5 - EAU2 SLEEPING New 09-A5 EAU2 Sl FFP_ING _ New 09-A5 FAI 12 S1 FFPING _ New 09-A5 - FAU2_SLEEP_ING _ _ New 01-A18 FAI12 SLEEPING New 09-A5 FAU3 CASITA New 09-A5 _ FAU3 CASITA New 09-A5 FAU3 CASITA New 28-A4 EAU3_CASITA New 09-A5 FA113 CASITA _ New 01-A18 FAU3 CASITA Run Initiation Time: 12/07/0910:51:03 Run Code: 1260211863 EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: �_ Page:1 of 9 Certificate Of Compliance : Residential (Part 2 of 4) CF-1 R Santerra Plan 4A Project Title 12/7/2009 Date FENESTRATION SURFACES True Cond. # Type Area U-Factors SHGC2 Azm. Tilt Stat. Glazing Type Location/ Comments -t- -Windoww-Eront (E)- 2 Window Left (S) 14.0 4.0 -055011&A_0..67116-B 0.390 NFRC 0.36 NFRC _ 90-90Nevy Double Non . taLClear FAU1 LIVING 180 90 New NonMetalLowE FAU1 LIVING 3 Window Left (S) 4.0 0.390 NFRC 0_36 NFRC 180 90 New NonMetalLowE - FAU1 LIVING 4 Window Left (S) 12.5 0.390 NFRC 0.36 NFRC 180 90 New NonMetalLowE FAU11 LIVING 5 Window Left (S) 12.5 0.390 NFRC 0_36 NFRC 180 90 New NonMetalLowE FAW LIVING 6 Window Rear (W) 21.0 0.390 NFRC 0.36 NFRC 270 90 New NonMetalLowE FAW LIVING 7 Window Rear (W) 48.0 0,390_N.F_RC 0.36 NFRC 270 -90 New NonMetalLowE FAW LIVING 8 Window Rear (W) 21.0 0.390 NFRC 0.36 NFRC 270 90 New NonMetalLowE FAU1 LIVING Window Rear (W) �2 .0 0.390 NFRC -D 36 NFRC2�7 �Q New NonMetalLowE FAW LIVING -9 IQ Window Rear (W) 64.0 0.399 NFRC 0.36 NFRC 270 90 New NonMetalLowE FAW LIVING 11 Window Rear JWJ 28.0 0.390 NFRC 0_36 NFRC 270 90 New NonMetalLowE FAU1 LIVING 12 Window Right (N) 25.0 0.390 NFRC 0_36 NFRC 0 90 New NonMetalLowE FAUi LIVING 13 Window-- ight (N) 22.0 0..390 NF_RG -QM _NFRC 0 -90 New NonMetalLowE FAU1 LIVING 14 Window Front (E) 30.0 0.390 NFRC 0_36 NFRC 90 90 New NonMetalLowE FAU2 SLEEPING _ 15 Window Front (E) 5.5 0.390 NFRC 0_36 NFRC 90 90 New FAU2 SLEEPING 16 Window Front (E)_ 13.8 0.390 NFRC 0_36 NFRC _NonMetalLowE 90 90 New NonMetalLowE FAU2 SLEEPING 17 Window Front 18 Window Front (E) (E) 40.0 13.8 0.390 NFRC 0_36 NFRC: 0.390 NFRC 0_36 NFRC 90 90 New NonMetalLowE 90 90 New NonMetalLowE FAU2 SLEEPING FAU2 SLEEPING 19 Window Front (E) 40.0 0.390FRC 0.36 NFRC 90 90 New NonMetalLowE FAU2 SLEEPING 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Tvpe SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt, 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Buy Screen 0.76 _. 6 Bug Screen 0.76 7 _ Bug Screen 0.76 8 Bug Screen 0.76 i 9 Bug Screen _ 0.76 7.0 4.0 8.0 0.5 8.0 8.0 10 Bug Screen 0.76 8.0 8.0 8.0 0.5 8.0 8.0 111 Bug Screen 0.76 7.0 4.0 8.0 0.5 8.0 8.0 12 Bug Screen 0.76 5.0 5.0 44.0 2.0 10.0 10.0 13 Bug Screen _ 0.76 14 Bug Screen 0.76 15 Bug Screen _ 0.76 _, 16 Bug Screen 0.76 17 Bug Screen 0.76 _ 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Tvpe (sf) (in.) Cap. Cond. R-Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R-Val. Location JA IV Reference Status Comments _ Slab Perimeter 170 None No Insulation 26-Al New FAW LIVING Slab Perimeter 155 None No Insulation 26-Al New FAU2 SLEEPING Slab Perimeter 86 None No Insulation 26-Ai New FAU3 CASITA EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: Page:2 of 9 Certificate Of COmDliance : Residential (Part 2 of 4) CF-1 R Santerra Plan 4A 12/7/2009 Project Title Date FENESTRATION SURFACES True Cond. Location/ # TVDe Area U-Factor' SHIS Azm. Tilt Stat. Glazing Tvoe Comments 20. Window Front (E)_ --13_8_-(1.390_N= 0.36 -NFRC 90_ -SO_ New NonMetalLowE S PIN , 21 Window Left (S) 48.0 0.390 NFRC 0.36 NFRC 180 90 New NonMetalLowE FAU2 SLEEPING 22 Window Left (S1 5.5 0.390 NFRC 0.36 NFRC 180 90 New NonMetalLowE FAU2 SLEEPING 23 Window Rear (W) 80.0 0.390 NFRC 0.36 NFRC 270 90 New NonMetalLowE FAU2 SLEEPING 24 Window Rear (W) 30.0 0.390 NFRC 0.36 NFRC 270 90 New NonMetalLowE FAU2 SLEEPING 25 Window Right (N) 5.0 0.390 NFRC 0.36 NFRC 0 90 New NonMetalLowE FAU2 SLEEPING 2fz Window Right (N)_ 6.0 0.390_NF_6G-Q36 NFR 0_ 90 New NonMetalLowE _FAU2 SLEEPING _ 27 Window Right (N) 30.0 0.390 NFRC 0.36 NFRC 0 90 New NonMetalLowE FAU2 SLEEPING 28 Window Right (N) 6.0 0.390 NFRC 0.36 NFRC 0 90 New NonMetalLowE FAU2 SLEEPING 29 Window Front (E) 15.0 0_390 NFRC 0.36 NFRC 90 90 New NonMetalLowE FAU3 CASITA 3Q Window Front _(E)_ 15.0 0.390 NFRC 0.36 NFRC 90 90 New NonMetalLowE FAU3 CASITA 31 Window Rear (Wj_ 14.0 0.550 116-A 0.67 116-B 270 90 New Double Non Metal Clear FAU3 CASITA 32 Window Reart)At� 20 0 0.390 NF8.CA.36 NFRC -270 90 New NonMetalLowE _EAU3 CASITA 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type _ SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 _ 21 Bug Screen 0.76 8.0 6.0 3.5 0.5 10.0 10.0 22 Bug Screen _ 0.76 23 Bug Screen _ 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen _ 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R-Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation R-Val. Location JA IV Reference Condition Location/ Status Comments EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: Page:3 of 9 1 Certificate Of Compliance : Residential (Part 3 of 4) CF-1 R Santerra Plan 4A 12/7/2009 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type FAU1 LIVING Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback FAU2 SLEEPING Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback FAU3 CASITA Split Heat Pump 8.00 HSPF Split Heat Pump 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R-Value Status Tested? FAU1 LIVING Ducted Ducted Attic 6.0 New Yes _ FAU2 SLEEPING Ducted Ducted Attic 6.0 New Yes _ FAU3 CASITA Ducted Ducted Attic 6.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R-Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Rheem 22VR75-70N FHR=109 Small Gas Recirc/Time+Temp 1 70,000 75 New 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation _ REMARKS THE CONTRACTORS ARE RESPONSIBLE FOR THE FINAL SIZING OF HEATING, COOLING AND DHW EQUIPMENT. (CEC Blueprint #60) COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 Of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Sk EConstruction Address: 2240 E , I itas Vvd Ste D485 TeleJEncini s CA 2024 hr/ 60-5 4 Lic. #: (signgture)- - !/ (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Mark Gallant, CEPE Title/Firm: Gallant Energy Consulting Address: 508 W Mission Avenue, Suite 201 Escondido, CA 92025 Telephone: 760 743-5408 12/7/09 (date) CABEC California *f Buildinq E-rgy i .ns 1tants Mirk Gallant R08-02-222 of 9 Certificate Of Compliance :Residential (Part 4 of 4) CF-1 R Santerra Plan 4A 12/7/2009 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aaencv determines the adeauacv of the justification, and may reject a building or design that otherwise complies 3ased on the adequacy of the special justification and documentation submitted. Plan I Field I The Roof "R-38 Roof Attic + rb" includes a Radiant Barrier. I I I HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field The HVAC System "FAU1 LIVING' incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. The HVAC System "FAU1 LIVING' incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "GMS80704/GSC13048/CP48A2B" includes credit for a 11.0 EER Condenser. The HVAC System "FAU2 SLEEPING' incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. The HVAC System "FAU2 SLEEPING' incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "GMS80905/GSC13060!CP60B2X" includes credit for a 11.0 EER Condenser. The HVAC System "FAU3 CASITA" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. The HVAC System "FAU3 CASITA" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "ARUF1824/GSH13024" includes credit for a 11.0 EER Condenser. I EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: Page:5 of 9 1 13 Residential Kitchen Lighting Worksheet WS-5R Santerra Plan 4A 12/7/2009 Project Title Date At least 50%of the total rated wattage of permanently installed luminaires in kitchens must be In luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts CAN Yes X1 No 26.0 x 8 = 208 or undercab 32w Yes X1 No 1 1 32.0 x 5 = 160 or _ Yes No x = or Yes No x = or Yes I No I L x = or Yes No x = or Yes No x = or Yes No x = or _ Yes No _ x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes I No I L x = _ or Yes No x = or Yes No x = or _ Yes No x = or Yes No x = or Yes _ No x = or _ Total A: 368 B: 0 COMPLIES IF A z B YES [XI NO ❑ EnergyPro 4.4 by Energysoft User Number: 2875 Job Number: _ Page:6 of 9 Y 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Santerra Plan 4A 12/7/2009 SYSTEM NAME FLOOR AREA FAW LIVING 1,350 ENGINEERING CHECKS ISYSTEM LOAD Number of Systems 1 Heating System Output per System 56,000 Total Output (Btuh) 56,000 Output (Btuh/sqft) 41.5 Cooling System Output per System 47,000 Total Output (Btuh) 47,000 Total Output (Tons) 3.9 Total Output (Btuh/sqft) 34.8 Total Output (sgft/Ton) 344.7 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sqft) 1.19 Airflow (cfm/Ton) 408.5 Outside Air (%) 0.0 L Outside Air (cfm/sgft) I 0.00 Dte: values above given at ARI conditions .ATING SYSTEM PSYCHROMETR Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I I COIL HTG. PEAK CFM I Sensible Latent I I CFM Sensible 984 18,883 0 1,730 608 20,050 1,597 1,714 0 0 0 0 0 0 0 0 0 1,714 1,597 22,312 1,730 23,244 GMS80704/GSC13048/CP48A2B 34,140 7,931 561000 Total Adjusted System Output 34,140 7,931 56,0001 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 26.0OF 69.1OF 69.1OF 102.0OF Outside Air 0 cfm 69.1 of 111.0 / 77.6 of Outside Air 0 cfm 79.0 / 65.1 of Supply Fan Heating Coil 1600 cfm Return Air Ducts 79.0 / 65.1 OF 79.0 / 65.1 of 59.0 / 57.8 of Supply Air Ducts Supply Air Ducts 101.0 OF ROOMS 70.0 of Supply Fan Cooling Coil 60.0 / 58.2 of 1600cfm 49.4% R.H. ROOMS, 78.0 / 64.8 OF Return Air Ducts I F EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: Page:7 of 9 J IHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE —� Santerra Plan 4A 12/7/2009 SYSTEM NAME FLOOR AREA FAU2 SLEEPING 1,549 Number of Systems 1 Heating System Output per System 72,000 Total Output (Btuh) Output (Btuh/sqft) 72,000 46.5 Cooling System Output per System 58,500 Total Output (Btuh) 58,500 Total Output (Tons) Total Output (Btuh/sqft) 4.9 37.8 Total Output (sgft/Ton) 317.7 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.29 Airflow.(cfm/Ton) + 410.3 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 of Outside Air 0 cfm 69.2 of 11.0 / 77.6 of Outside Air 0 cfm 79.0 / 66.2 ° F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 1,367 23,307 11867 1 632 21,667 0 0 01 2,116 1,721,7266 01 0 1,726 0 0 0 0 2,116 F—27,540 1,867� 25,119 GMS80905/GSC13060/CP6062X 38,341 15,027 72,000 I 72,000 Total Adjusted System Output �38,341 15,027I (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 69.2OF 69.2OF 103.0OF SL,,pply Fan Heating Coil 2000 cfm Return Air Ducts 79.0/66.2OF 79.0/66.3OF 61.0/59.9OF Supply Fan 2000 cfm Supply Air Ducts 102.2 of ROOMS 70.0 of Supply Air Ducts Cooling Coil 62.0 / 60.3 of 53.3%'R.H. ROOMS 78.0 / 65.9 of Return Air Ducts 1 i EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: _ Page:8 of 9 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY (PROJECT NAME DATE Santerra Plan 4A 12/7/2009 SYSTEM NAME FLOOR AREA FAU3 CASITA 323 Number of Systems 1 Heating System Output per System 24,000 Total Output (Btuh) 24,000 _ Output (Btuh/sqft) 74.3 Cooling System Output per System 23,400 Total Output (Btuh) 23,400 Total Output (Tons) 2.0 Total Output (Btuh/sqft) 72.4 Total Output (sgft/Ton) 165.6 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 2.48 Airflow (cfm/Ton) 410.3 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 of Outside Air 0 cfm 69.4 of 111.0 / 77.6 OF Outside Air 0 cfm 78.9 / 66.2 °F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 489 8,507 1,023 456 7,941 0 772 533 0 0 0 0 0 0 0 0 0 772 533 10,05 1 023 9,007 AR UF1824/GSH13024 15,453 5,879 14,990 Total Adjusted System Output 15,453 5,879 14,990 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK C_Aug 2 pm Jan 12 am 659.4OF 69.4OF 87.0OF Supply Fan Heating Coil 800 cfm Return Air Ducts 78.9 / 66.2 OF 78.9 / 66.3 OF 60.8 / 59.7 OF Supply Fan 800 cfm Supply Air Ducts 86.4 OF ROOMS 70.0 of Supply Air Ducts Cooling Coil 61.7 / 60.0 of 53.2% R.H. ROOM 78.0/65.9OF Return Air Ducts EnergyPro 4.4 by EnergySoft User Number: 2875 Job Number: Page:9 of 9