Loading...
Santerra TR 32225 13-0620 (SFD) (Plans 2471, 2624, 3117 & 3418; Lots 7-20)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: 13-00000620 57721 BARRISTO CIR 762-SOO-007-7 -32225 - DWELLING - SINGLE FAMILY LOW DENSITY RESIDENTIAL 302733 &sineand I hereby affirm under penalty o Section 7000) of Division 3 ofLicense Class: B D is eic'y 6i—/� Contra ,Date: Da T4&t 4�� _ VOICE (760) 777-7012 FAX (760) 777-7011 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 10/30/13 Owner: MURRIETA APTS INVESTORS 37, LP 400 E RINCON STE 105 DETACHED - CORONA, CA 92879 1_. Contractor: Architect or Engineer: M H P BUILDERS INC 3202 W. MARCH LANE, STOCKTON, CA 95219 01P (209)951-6190 Lic. No.: 934711 #ACTOR'S DECLARATION ode/provisions of Chapter 9 (commencing with ds Code, and my License is in full force and effect. License No.: 934711 OWNER -BUILDER DECLARATION I herebyaffirm under penalty of i ur that I am exempt from the Contractor's State License Law for the P Y I Y P following reason (Sec. 7031. usiness and Professions Code: Any city or county that requires a permit to construct, alter, improve, de olish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I _ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). y Lender's Name: t Lender's Address: t #A CIT 1' OF LA QUANTA FINANCE DEPT. WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workerscompensation insurance carrier and y n er Carrier EVEREST INS Po Number 7690046121 I certify that, in the erfor nce of a ork for which this permit is issued, I shall not employ any person in any m ne so s to me subject to the workers' compensation laws of California, and agree that, if I .be ubject to the workers' compensation provisions of Section f 37050 of the Labo%Co , I s fo hwith comply with those provisions. :Date:/ &—J& �/; Applican r .l, WARNING: FAILURE TO SEC E WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER T RIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being ' performed under or following issuance of this permit. 2. Any permit issued as a result of this applica ' omes null nd void if work is not commenced within 180 days from date of iss7propegfy rmit or. sation of work for 180 days will subject permit to cancellation. certify that I have read this application and st1 is -correct. I agree to comply with all city and county ordinances and state laws relag cons coon and hereby authorize representatives of this county to enter upon the above-mentioor in ction urposes. Date: /0O1`5-5Signature (Applicant or A Ia LQPERMIT Application Number . . . . . 13-00000620 ------ Structure Information 3,418SF DWELLING/VB/RES-3/CL-A/13D [ENG]----- Other struct info . . . . . CODE EDITION 2010 # BEDROOMS 3.00 FIRE SPRINKLERS 13D GARAGE SQ FTG 685.00 PATIO SQ FTG 463.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 3418.00 ---------------------------------------------------------------------------- Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 1350.00 Plan Check Fee 877.50 Issue Date . . . . Valuation . . . . 302733 Expiration Date . . 4/28/14 Qty Unit Charge Per Extension BASE FEE 639.50 203.00 3.5000 THOU BLDG 100,001-500,000 710.50 ---------------------------------------------------------------------------- Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 148..33 Plan Check Fee 37.08 Issue Date . . . . Valuation . . . . 0 Expiration Date 4/28/14 Qty Unit Charge Per Extension BASE FEE 15.00 3418.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 119.63 685.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 13.70 ---------------------------------------------------------------------------- Permit . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Issue Date . . . . Expiration Date . . 4/28/14 Plan Check Fee . Valuation . . . Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 94.50 Plan Check Fee 23.63 Issue Date . . . . Valuation . . . . 0 LQPERM[T Application Number . . . . . 13-00000620 Permit . . . . . . MECHANICAL Expiration Date 4/28/14 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 5.00 6.5000 EA MECH VENT FAN 32.50 1.00 - - - - - - - - - - - - - - - 6.5000 - - - - - - - - - - - EA - - - - MECH - - - - - - - EXHAUST HOOD - - - - - - - - - - - - - - 7 - - - - - - - - - - 6.50 - - - - - - - - - - - - - - Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 159.75 Plan Check Fee 39.94 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/28/14 Qty Unit Charge Per Extension BASE FEE 15.00 15.00 6.0000 EA PLB FIXTURE 90.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 7.00 .7500 EA PLB GAS PIPE >=5 5.25 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 3,418SF DWELLING - ELEV A, GAR 3L, LOT 7 [VB/RES-3/CLASS A-FR/13D/ENGINEERED] THIS PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL, SPA OR DETACHED BBQS AND FIRE PITS. 2010 CALIFORNIA BUILDING . CODE . October 2, 2013 3:18:59 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES-RES 256.83 BLDG STDS ADMIN (SB1473) 13.00 DIF COMMUNITY CENTERS-RES 129.00 DIF CIVIC CENTER - RES 942.00 ENERGY REVIEW FEE 87.75 DIF FIRE PROTECTION-RES 433.00 GRADING PLAN CHECK FEE 15.00 HOURLY PLAN CHECK 784.00 DIF LIBRARIES - RES 344.00 MULTI -SPECIES (MSHCP) FEE 1278.00 DIF PARK MAINT FAC - RES 40.00 LQPERMIT Application Number . . . . . 13-00000620 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . DIF PARKS/REC - RES 2048.00 STRONG MOTION (SMI) - RES 30.27 TUMF: RESIDENTIAL 1837.44 DIF STREET MAINT FAC-RES 116.00 DIF TRANSPORTATION - RES 2842.00 Fee summary Charged Paid Credited Due Permit Fee Total 1767.58 .00 .00 1767.58 Plan Check Total 978.15 500.00 .00 478.15 Other Fee Total 11196.29 .00 .00 11196.29 Grand Total 13942.02 500.00 .00 13442.02 LQPERMIT Bin. # CQ%/ Of is QUfnta Building &r Safety Division D a Permit # P.O. Box 1504, 78-495 Calle Tampico La.Quinta, CA 92253 - (760) 777-701 ?j Building Permit Application and Trac g ShdVAY q .8 2CIS 4 �'7 Project Address: `' '7� , Owner's Name:. Mum eta AP rtm e A. P. Number: Address: 3202 W. March Lane, u i FINA CE DEPT Legal Description: Lots 7-20 of Tract 32225 City, ST, Zip: Stockton, CA, 95219 Contractor: M H F Builders, Inc. Telephone: 209.951.6190 Address: 32021N. March Lane, suite A Project Description: Four (4) single family residences . city, sT, zip: Stockton, CA, 95219 for lots 7-20 of Tract 32225 Telephone: 209.951.6190ME State Lie. # : 934711 City Lie. #.: Arch., Engr., Designer: Ross Kuster (SEOR) Address: 2755 Bristol Street, Suite 100 City, ST, Zip: Costa Mesa, CA, 92626 `fete hone:714.556.1916 `�` P •, <. Construction Type: .VB Occupancy: R-3/U State Lie. #• '- ' . 48386 %�.�, �j�:y: r • Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: M a rco H u rto d o Sq. Ft.: # Stories: Sin I e # Units: Telephone # of Contact Person: 951.552.7004 X 7683 Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Reed TRACKING PERMFP FEES Plan Sets an Chec su witted Item Amount Structural Cafes. ewed ady.for corrections d3 13 Plan Check Deposit_ . Truss C21cs. a Contact Person Plan Check Balance Title 24 Calcs. P ieked up Construction Flood plain plan Plans resubmitted.. '3 Mechanical Grading plan 2"a Review, ready fo correctian issue Electrical Subcontactor List Called Contact Person 7 1 Plumbing Grant Deed Plans picked up S.M.L H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"` Review, ready for corrections/issue Developer Impact Fee Planning Approval. Called Contact Person A.I.P.P. Pub. Wks. Appr . Date of permit issue School Fees Total Permit Fees T4ht " Building & Safety Department 78-495 Calle Tampico La Quinta, CA 92253 (760) 777-7125 voice — (760) 777-7011 fax To: Les Johnson, Community Development Director To: PD: October 17, 2013 From: Greg Butler, Building Official Due date: ASAP Permit #13-620 Status: 1ST Review Building Plans Approval (This is an approval to issue a Building Permit) CVMSHCP Applicable Fee YN/A The Planning Department has reviewed the Building Plans for the following project: Description: Santerra tract Address or general location: 57721 Barristo Lots 7-20 of Tract 32225 Applicant Contact: Marco Hurtado (951) 582-7004 ext. 7683 The Planning Department finds that: ❑ ...these Building Plans do not require Planning Department approval. ...these Building Plans are approved by the Planning Department. ❑ ...these Building Plans require corrections. Please forward a copy of the attached corrections to the applicant. When the corrections are made please return them to the Planning Department for review. ,Olt Les Johnson, Community Development Director Date NOTE: PLEASE RETURN PLANS WITH GREEN SHEET TO THE BUILDING AND SAFETY DEPARTMENT T4&f 4 44umra MEMORANDUM TO: GREG BUTLER, BUILDING OFFICIAL FROM: WALLY NESBIT, PRINCIPAL PLANNER 12,----- DATE: 1 10/29/2013 RE: SANTERRA BUILDING PLAN CHECK; LOTS 7-20 The Community Development Department has reviewed the above proposed plans for Santerra, which was originally granted architectural and landscape approvals under Site Development Permit 2006-861 . 1. Based on the plans and elevations as approved by Planning Commission on 6/27/06, staff has determined that the proposed unit plans are compatible with those previously approved plans for Santerra, and no additional review is necessary. 2. Per Condition 13 of the Planning Commission approval, all "S" roof the shall be a tri-color mix. If you have any questions, please contact me at x7069. Plan Check Lots 7-20_Bldg t�\ P.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO (760) 7 7 7 - 7 0 0 0 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7101 June 11, 2013 Mr. Marco Hurtado Legacy Homes 400 E. Rincon Street, #105 Corona, CA 92879 SUBJECT: MODIFICATION BY APPLICANT 2013-052: COMPATIBILTY OF PARTIALLY DEVELOPED SUBDIVISION Dear Mr. Hurtado: The Community Development Department hereby approves your request for modifications to the approved housing unit designs within the Santerra housing tract (TTM 32225), within the City of La Quinta. The design changes to the single-family homes are approved pursuant to L.Q.M.0 9.60.300 "Compatibility Review for Partially Developed Subdivisions", and include changes to the exterior facades and interior floor plans for approved units 2 - 5. The modifications of the homes are subject to the following conditions: 1. The applicant is permitted to make design and architectural changes to the home's exterior, changes to the home's square footage, and changes to the interior floor plans of units 2 thru 5, approved under Site Development Permit 2006-861. No changes are permitted for approved unit 1 . 2. The proposed housing units shall conform with the following square footage limitations: a. Unit 1 - No Changes b. Unit 2 - 2,500 square feet c. Unit 3 - 2,650 square feet d. Unit 4 - 3,150 square feet e. Unit 5 - 3,450 square feet Changes to the overall floor area of the individual units shall not be greater than N Nn 10% of the original unit square footage. 3. The approved architectural changes shall conform to the plans and building elevations on file as part of this application. 4. The use of a three -car garage is permitted for units 3, 4, and 5. Unit 4 shall be a tandem three -car garage. 5. The exterior building treatment and materials shall be compatible with the exterior treatments on the existing approved units at the Santerra development. The materials proposed for the unit changes shall conform to the materials board on file as part of this application. 6. The applicant is permitted to replace exterior lighting fixtures with new wall scones. All new lighting shall conform to the City's Lighting Ordinance for shielding and filtration requirements as contained in Section 9.100.150 of the La Quinta Municipal Code. 7. The applicant shall submit a revised precise grading plan to the City's Building Divisions prior to receiving approval of building permits for construction of the homes. 8. The applicant shall conform to the existing common area and front yard typical landscape plans for all new units within the Santerra development (FLP 07-003). A landscape sheet shall be submitted with the building plans. 9. The applicant shall obtain building permits prior to construction of the approved building modifications. 10. The applicant shall conform to the Conditions of Approval for Tentative Tract Map 32225. This approval will be forwarded to the Building and Safety Department for their information. If you have any questions regarding the approval of this request, please contact me at (760) 777-7125 or ILohnson@la-quinta.or9. Sinc/rell. LES AOHNSON Community Development Director C: Greg Butler, Building and Safety Division m Building Permit Number: ro Project Description: SFR Exempt: (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan "Blanket Plan for all 14 lots** Plan Submittal Datel 7/3/2013 JobSlteAddressl 57721, 57755, 57789, 57823, 57857, 57891, 57925, 57928, 57900, 57872, 57844, 57816, 57788, 57760 Barristo Cir Owner's Name Legacy Homes Number, Street, or PO Box 400 E. Ricncon St., #105 city, state, Postal Code Corona, CA 92879 Owners Phone Number 951-582-7004, ext. 7636 Owners E-Mall Address dcanomagacvhomesuse com Project Managers Name James Turnbull Project Managers Phone Number 272-5236 Project Managers E-mall Address - Builder / Contractor I MH P Contractors Number, street or PO Boxi 3202 W. March Lane, Unit A City, state, Postal code I Stockton, CA 95219 Project Square Footage) 41,300 City Approval By Date of City Approval Materials To Be Discarded: Product Tons Trash 78.47 Not recyclable Product Tons Asphalt 0.00 Recyclable Masonry (broken) 0.00 Recyclable Brick/Block 0.00 Recyclable Plaster 8.26 Recyclable Cardboard 13.63 Recyclable Scrap Metal 0.00 Recyclable Commingled 0.00 Recyclable Tile (floor) 7.02 Recyclable Concrete 3.30 Recyclable Tile (roof) 0.00 Recyclable Drywall 2.44 Recyclable Wood 103.25 Recyclable Donated / Reuse" 0,00 Recyclable Landscape Debris 0.00 Recyclable *Describe Items Totals: Recycle Trash Projected Diversion: 137.9 78.5 63.7% I understand It Is the property owners responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls.occur. I hereby certify that completion, Implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the Jobsite waste is diverted from landflliing. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project In accordance with this plan. This DMP is Issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor se t nf owner may obtain a DMP for the owner. However, the DMP is still issued In the name of the property o s) d the owner tains legal responsibility for ensuring that the provisions of the DMP are adhered to. T roperty own (s) an eneral contr r shall be kept Informed of the diversion progress through bi-monthly reports. If -hauling, all refuse erial from this act site must be taken to an approved recycler or transfer station. Owner / Developer ! Prbje&Vffanager / Superintendent Data A l rig 45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-I369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 800 E. Florida Avenue, Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778 August 20, 2013 Project No. 544-13093 13-08-401 Murrieta Apartment Investors 37, L.P. 3202 West March Lane, Suite A Stockton, California 95219 Project: Santerra — Tract 32225 Lots 7 Through 20 NWC Avenue 58 & Madison Street La Quinta, California Subject: Foundation and Grading Plan Review RECEIVEUr-, AUG 2s2 2013 CITY OF LA QUINTA COMMUNITY DEVELOPMENT Ref: Geotechnical Update prepared by Sladden Engineering dated April 23, 2013; Project No. 544-13093, Report No. 13-04-143 As requested, we have reviewed the Precise Grading PIans prepared by Love Engineering along with the Foundation Plans and Details prepared by Option One Consulting Engineers. The plans reviewed were prepared for the Santerra residential development (Tract 32225). The Foundation Plans reviewed included Floor Plans 2, 3, 4 and 5. Based on our review, it is our opinion that the recommendations provided in the above referenced Geotechnical Update as well as the previous geotechnical reports have been properly incorporated into these plans. If you have questions regarding this memo or the above referenced report, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEEI Brett L. Anderson Principal Engineer Letter/gvm aECTT L. ANDEBSON tqo. C45389 c= rVrl cr��or,vEcR1PJG 3 Copies: 4 / Murrieta Apartment Investors 37, L.P. Sladden Engineering 45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 800 E. Florida Avenue, Hemet. CA 92543 (951) 766-8777 Fax (951) 766-8778 April 23, 2013 Legacy Homes 54425 Avenida Martinez La Quinta, California 92253 Project: Santerra — Tract 32225 Lots 7 Through 20 NWC Avenue 58 & Madison Street La Quinta, California Subject: Geotechnical Update REQEA 3093 - -143 MAYAgsCrFV CI7Y OF MUD COMTq MUNI7-Y MAIf 1 W01ENT Ref: Geotechnical Engineering Report prepared by Earth Systems Southwest (ESS) dated February 6, 2004; File No. 09483-01, Report No. 04-02-706. Report of Observation and Testing During Rough Grading report prepared by Sladden Engineering dated February 27, 2007; Project No. 522-06635, Report No. 07-02-160 As requested, we have reviewed the above referenced geotechnical report as it relates to the design and construction of the proposed residential development. The project site is located on the northwest corner of Avenue 58 and Madison Street in the City of La Quinta, California. It is our understanding that the proposed residences will be a relatively lightweight wood -frame structures supported by conventional shallow spread footings and concrete slabs on grade. The referenced Geotechnical Engineering Report includes recommendations pertaining to the construction of residential structure foundations. Based upon our review of the referenced reports, it is our opinion that the structural values included in the referenced grading report prepared by Sladden Engineering remain applicable for the design and construction of the proposed residential structure foundations. Because the development has been previously rough graded, the remedial grading required at this time should be minimal provided that the buildings fall within the .previously graded building envelope. The building pads should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted to a minimum of 90 percent relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. Several of the lots (14, 15 & 1.6) remain low and will require additional fill placement to attain the designed grade. )If April 23, 2013 -2- Project No. 544-1.3093 13-04-143 Footings should extend at least 12 inches beneath lowest adjacent grade. Isolated square or rectangular footings at least 2 feet square may be designed using an allowable bearing value of 2000 pounds per square foot. Continuous footings should be at least 12 inches wide may be designed using an allowable bearing value of 1800 pounds per square foot. Allowable increase of 200 psf for each additional 1. foot of width and 200 psf for each additional 6 inches of depth may be utilized if desired. The maximum allowable bearing pressure should be 2500 psf. The allowable bearing pressures are for dead and frequently applied live loads and may be increased by 1/3 to resist wind, seismic or other transient loading. Lateral forces may be resisted by friction along the base of the foundations and passive resistance along the sides of the footings. A friction coefficient of 0.50 times the normal dead load forces is recommended for use in design. Passive resistance may be estimated using an equivalent fluid weight of 300 pcf. If used in combination with the passive resistance, the frictional resistance should be reduced by one third to 0.33 times the normal dead load forces. The bearing soils are non -expansive and fall within the "very low" expansion category in accordance with Uniform Building Code (UBC) classification criteria. Pertinent 2001 CBC Seismic Design parameters are summarized below. Based on our field observations and understanding of local geologic conditions, the soil profile type judged applicable to this site is SD, generally described as stiff soil. The following presents additional coefficients and factors relevant to seismic mitigation for new construction based upon the 2010 California Building Code (CBC). The seismic design category for a structure may be determined in accordance with Section 1613 of the 201.0 CBC or ASCE7. According to the 2010 CBC, Site Class D may be used to estimate design seismic loading for the proposed structures. The 2010 CBC Seismic Design Parameters are summarized below. Occupancy Category (Table 1604.5): H Site Class (Table 1613.5.5): D Ss (Figure 1613.5.1: 1.50g S1 (Figure 1613.5.1.: 0.60g Fa (Table 1613.5.3(1)): 1.0 Fv (Table 161.3.5.3(2)):1.5 Sms (Equation 16-36 (Fa X Ss)): 1.50g Smi (Equation 16-37 (Fv X S11): 0.90g SDS (Equation 16-38 (2/3 X Sms}): 1.00g SD1(Equation 16-49 (2/3 X Sm1}): 0.60g Seismic Design Category D April 23, 2013 -3- Project No. 544-13093 13-04-143 If you have questions regarding this letter or the referenced reports, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERIN Brett L. Anders n Principal EngineerB ETT ti ANDERSON No. C15389 SER/gl LW Exp. 9130114 Cr CIVIL ENGINEERING Copies: Q Legacy Homes J/7_ /,)LU7`j LA QUIN'TA Please verify that soils reports contain all of the above information. In addition, to assure continuity between the investigation/reporting stage and the execution stage, please use the following checklist to verify that the conclusions and recommendations in the report cover all the required elements. Only then can we be assured that the construction documents address all of the site soil conditions. La Quinta Geotechnical Report Checklist Does the "Conclusions and Recommendations" section of the report address each of the following criteria? "Address" means: (a) the criterion is considered significant and mitigation measure(s) noted, or; (b) the criterion is considered insignificant and explicitly so stated. Yes No Criterion ® Foundation criteria based upon bearing capacity of natural or compacted soil. ® Foundation criteria to mitigate the effects of expansive soils. ® Foundation criteria based upon bearing capacity of natural or compacted soil. f ® Foundation criteria to mitigate the effects of liquefaction. ® Foundation criteria. to mitigate the effects of seismically induced differential settlement, rl 0 Foundation criteria to mitigate the effects of long-term differential settlement. ® Foundation criteria to mitigate the eff. ects of varying soil strength. ® Foundation criteria to mitigate expected total and differential settlement. Any "No" answers to the above checklist should be noted as specific required corrections. CSWn-vla Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID . AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Santerra Phase 2 (Tract 32225)] Date: June 26, 2014 Owner's Name: �Murrieta Apartment Investors 37, LP/ M HP Builders Phone No. 951-582-7004 Ext 7626 Project Address: 57-823 Barristo Circle/ 57-857 Barristo Cirlce/ 57-816 Barristo Circle/ 57-844 Barristo Circle La Quinta,.CA 92253 Project Description: Four Single Family Dwelling 762-500-010/762-500-011/ APN: 762-500-018/ 762-500-017 Tract #: 32225 Lot #'s: Lot 10/ Lot I I/ Lot 18/ Lot 17 Type of Development: Residential XXi Commercial. Industrial Total Square Feet of Building Area: 11,630 Sq. Ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on If of the owner/developer. l k' Dated: a } - �" Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project. . 17620 65995 Approval Number of Sq.Ft. 11,630 Amount per Sq.Ft. $3.20 Amount Collected $37,216.00 Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Agreement Existing Not Subject to Fee Prior toR�Q:IVED Requirement ""1 2 6 201, CITYor L_4 CpNj"UN11�' ,4u SA Certificate issued by: Leticia C. Torres, Facilities Analyst Sign lure: AlVdcl' r NOTICE OF 90 DAY PERIOD FOR PROTEST O�tt�D ATENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires t at this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90-day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions maybe granted. MV:c/mydocsldevl.ees/certificate of compliance ionn updated 3-2007 11/2010 Cox&Ma Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 . This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: RECEIPT: CHECK #: IN CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Santerra Phase 3 (Tract 32225) Date: June 26, 2014 Owner's Name: Murrieta Apartment Investors 37, LP/ M HP Builders Phone No. 951-582-7004 Ext 7626 Project Address: 57-891 Barristo Circle/ 57-900 Barristo Cirlce/ 57-872 Barristo Circle, La Quinta, CA 92253 Project Description: Three (3) Single Family Dwelling APN: 762-500-012/ 762-500-015/762.-500-016 Tract #: 32225 Lot #'s: Lot 12/ Lot 151 Lot16 Type of Development: Residential XX Commercial Industrial Total Square Feet of Building Area: 8,212 Sq. Ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated:(' Signature: /l�J SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prio /87 Requirement CF1 Number of Sq.Ft. 8,212 'D p Amount per.Sq.Ft. $3.20 J Amount Collected $26,278.40 CI UN 2 62014 M Building Permit Application Completed: Yes/No CQ Gig tA By: Elsa F. Esqueda, Director of Facilities and Maintenance MUNI 14un,Tla Certificate issued by: Leticia C. Torres, Facilities Analyst Sign ature: NOTICE OF 90 DAY PERIOD FOR PROTEST OFF EFR9 AN)b STAUNIENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90-day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date:of.issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/mydoes;devfees/certificate of.coiripliance form updated 3-2007 11/2010 Coacti a Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Santerra_(Phase 1) Owner's Name: Murrieta Apartment Investors 37, LP Project Address: 57-721/ 57-755/ 57-789/ 57-760 / 57-788 Barristo Circle, La Quinta, CA Project Description: 5 Single Family Dwelling 762-250-007/762-250-008/762-250- 009/ 762-250-009/762-250-020/ APN: 762-250-019 Tract #: 32225 Type of Development: Residential XX Total Square Feet of Building Area: Certification of Applicant/Owners: The person si penalty of perjury and further represents that he/she Dated: d 50 Signature: SCHOOL DISTRICT'S REQUIREMENTS ACCORDANCE WITH ONE OF THE FOI Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 15,048 $3.20 $48,153.60 Commercial Date: October 30, 2013 Phone No. 760-272-5236 Lot #'s: 7, 8, 9 . FT. 19 Industrial information is correct and makes this statement under .f of the owner/developer. IE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN IG: (CIRCLE ONE) Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Leticia Torres, Facilities Analyst NOTICE OF 90 DAY PERIOD FOR PROTEST OVFE X81ANIf STAIrEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires tha thi istrict provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90-day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. M V:c, mydocs/dcvfees/certificate of compliance form updated 3-2007 11/2010 PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALIMESA CANYON LAKE C OAC H E LLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO LAKE ELSINORE LA QUINTA MENIFEE MORENO VALLEY PALM DESERT PERRIS RANCHO MIRAGE RUBIDOUx CSD SAN JACINTO TEMECULA WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT 1 JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY . DISTRICT 5 RIVERSIDE COUNTY FIRE DEPARTMENT IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 • Phone (760) 863-8886 • Fax (760) 863-7072 www.rvcfire.org February 21, 2014 Fire Sprinkler Systems Re: Residential Fire Sprinkler Plan Review LAQ-13-RS-090 Santerra Lot #7 57-721 Barristo Circle La Quinta, CA The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department Planning & Engineering personnel and are approved with the following conditions: NOTE: Refer to sheet FP2 for "re -lined" change to plan. Permanently marked identification signs shall be attached to all control valves. A warning sign, with minimum '/ inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign. The following inspections/tests are required to be witnessed by the Fire Department Planning Division staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. (b) Final inspection. The Fire Department job card, approved plans and conditions letter must be at the job site or NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection date. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Applicant/installer shall be responsible to contact the Fire Department to sched I oinaction. Sincerely, Jaso Stubble Fire Safety Specialist