Loading...
12-1348 (SFD) Title 24BUILDING ENERGY ANALYSIS REPORT PROJECT: The Madison Club Lot 54B La Quinta, Ca 92253 Project Designer: TDC Associates Design and Drafting Po Box 1654 .La Quinta, CA 92253 (760) 771-6589 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780�2� ���� CIN OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA Job Number: Date: 12/20/201 ,ptJ 1'12��3 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential an. �onyesidenial 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC -- www.energysoff.com. 1 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 6712 1 2 3 13 16 19 22 25 s 0 W-] • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name The Madison Club Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 11212012012 Date Project Address Lot 54B La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,978 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 5,942 Radiant Barrier New Wall Wood Framed R-21 3,868 New Slab Unheated Slab -on -Grade None 5,978 Perim = 518' New Door Opaque Door None 20 New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Skylight 12.3 0.590 0.39 none none None New Front (N) 257.5 0.520 0.29 none none Bug Screen New Left (SE) 52.0 0.280 0.26 none none Bug Screen New Rear (S) 115.0 0.520 0.29 none none Bug Screen New Rear (Std 59.0 0.280 0.26 none none Bug Screen New Skylight 4.0 0.590 0.39 none none None New Skylight 4.0 0.590 0.39 none none None New Skylight 8.0 0.590 0.39 none none None New Front (NE) 28.8 0.280 0.26 none none Bug Screen New Left (E) 185.0 0.520 0.29 none none Bug Screen New Left (SE) 16.0 0.280 0.26 12.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER No Setback New 3 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3,4 & 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 2 Small Gas 75 0.66 All Pipes Ins New EnergyPry 5.1 by EnergySoft User Number: 6712 RunCode: 2012-12-20712:34:44 ID: Page 3 of 30 C] • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name The Madison Club Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 11212012012 Date Project Address Lot 54B La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,978 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Rear (SM 90.0 0.520 0.29 none none Bug Screen New Right (tM 57.2 0.280 0.26 none none Bug Screen New Right (NIM 220.0 0.520 0.29 none none Bug Screen New Right (NK9 25.0 0.280 0.26 none none Bug Screen New Skylight 8.0 0.590 0.39 none none None New Front (N) 128.0 0.280 0.26 none none Bug Screen New Front (NE) 62.0 0.520 0.29 none none Bug Screen New Left (E) 105.6 0.280 0.26 10.0 none Bug Screen New Left (E) 97.0 0.520 0.29 10.0 none Bug Screen New Left (SE) 49.3 0.280 0.26 10.0 none Bug Screen New Rear (SE) 21.0 0.280 0.26 10.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-12-20712:34:44 ID: Page 4 of 30 • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name The Madison Club Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 11212012012 Date Project Address Lot 54B La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,978 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Rear (S) 110.0 0.520 0.29 10.0 none Bug Screen New Rear (S) 216.0 0.280 0.26 10.0 none Bug Screen New Right (SK9 50.3 0.280 0.26 10.0 none Bug Screen New Right (SW) 78.0 0.520 0.29 10.0 none Bug Screen New Right (tM 48.0 0.520 0.29 none none Bug Screen New Right (Vo 32.0 0.280 0.26 10.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro, 5.1 by EnergySoft User Number.' 6712 RunCode: 2012-12-20712:34:44 ID: Page 5 of 30 9 • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name The Madison Club Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11212012012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw reuirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 731.0 112 Covered Slab Floor, 3.500" thick at Sleeping Space HIGH MASS Design - Verify Thermal Mass: 393.0 ft2 Exposed Slab Floor, 3.500" thick at Sleeping Space HIGH MASS Design - Verify Thermal Mass: 1,050.0 ft2 Covered Slab Floor, 3.500" thick at Sleeping Space HIGH MASS Design - Verify Thermal Mass: 390.0 ft2 Exposed Slab Floor, 3.500" thick at Sleeping Space The HVAC System HVAC 3, 4 & 5 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 508.0 ft2 Covered Slab Floor, 3.500" thick at Living Space HIGH MASS Design - Verify Thermal Mass: 2,906.0 ft2 Exposed Slab Floor, 3.500" thick at Living Space The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 4 Ton includes credit for a 12.5 EER Condenser A certified HERS rater must field verity the installation of the correct Condenser. The HVAC System HVAC 1 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 5 Ton includes credit for a 12.7 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier Split DX/FAU includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3, 4 & 5 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. EneMyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2012-12-20712:34:44 ID: Page 6 of 30 • • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name The Madison Club Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11212012012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The HVAC System HVAC 3,4 & 5 incorporates HERS Verified Refrigerant Charge ora Charge Indicator Display. The HVAC System HVAC 3, 4 & 5 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 3, 4 & 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. h—ne—mvPr, 5.1 by EneMySoft User Number 6712 RunCode: 2012-12-20712:34:44 ID: Pae 7 of 30 • • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type O Single Family ❑ Addition Alone Date The Madison Club I ❑ Multi Family ❑ Existing+ Addition/Alteration 11212012012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 4.08 6.37 -2.29 Space Cooling 52.45 46.25 6.20 Fans 10.44 12.25 -1.81 Domestic Hot Water 6.10 6.43 -0.33 Pumps 0.00 0.00 0.00 Totals 73.07 71.30 1.77 Percent Better Than Standard: 2.4 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: • (N) 0 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 1,532 476 Fuel Available at Site: Natural Gas (E) 1,397 505 Raised Floor Area: 0 (S) 1,225 611 Slab on Grade Area: 5.978 (VVJ 1,837 511 Average Ceiling Height: 11.7 Roof 5,978 36 Fenestration Average U -Factor: 0.42 TOTAL: 2,139 Average SHGC: 0.28 Fenestration/CFA Ratio: 35.8.% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and comple Documentation Author Company Scott Design and Title 24, Inc, 12/20/2012 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone (760) 2004780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company TDC Associates Design and Drafting A Address Po Box 1654 Name Brian de Coster City/State/zip La Quinta, CA 92253 Phone (760) 771-6589 Signed License # Date EnemvPro 5.1 by EnemySoft user Number: 6712 RunCode: 2012-12-20712:34:44 ID: Page 8 of 30 • • C] CERTIFICATE OF COMPLIANCE: Residential Part 4 of R Project NameType Madison Club "5C!F-I m Single Family ❑Addition AloneThe ❑ Multi Family ❑ Existing+ Addition/A0/2012 OPAQUE SURFACE DETAILS Surface T e Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,112 0.026 R-38 270 0 New 4.2.1-A9 Master Suite Wall 43 0.069 R-21 0 90 New 4.3.1-A6 Master Suite Wall 179 0.069 R-21 135 90 New 4.3.1-A6 Master Suite Wall 60 0.069 R-21 180 90 New 4.3.1-A6 Master Suite Wall 68 0.069 R-21 225 90 New 4.3.1-A6 Master Suite Wall 385 0.069 R-21 270 90 New 4.3.1-A6 Master Suite Slab 731 0.730 None 0 180 New 4.4.7-A1 Master Suite Slab 393 0.730 None 0 180 New 4.4.7-A1 Master Suite Roof 1,424 0.026 R-38 270 0 New 4.2.1-A9 Bdrms 2, 3, 4 & Guest Livi Wall 39 0.069 R-21 01 90 New 4.3.1-A6 Bdrms 2, 3, 4 & Guest Livi Wall 329 0.069 R-21 30 90 New 4.3.1-A6 Bdrms 2, 3, 4 & Guest Livi Wall 167 0.069 R-21 90 90 New 4.3.1-A6 Bdrms 2, 3, 4 & Guest Livi Wall 104 0.069 R-21 120 90 New 4.3.1-A6 Bdrms 2, 3, 4 & Guest Livi Wall 163 0.069 R-21 180 90 New 4.3.1-A6 Bdrms 2, 3, 4 & Guest Livi Wall 97 0.069 R-21 210 90 New 4.3.1-A6 Bdrms 2, 3, 4 & Guest Livi Wall 134 0.069 R-21 270 90 1 New 14.3.1-A6 18dryns 2, 3, 4 & Guest Livi FENESTRATION SURFACE DETAILS ID Tvpe Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Skylight 12.3 0.590 NFRC 0.39 1 NFRC 270 New Skylight Master Suite 2 Window 140.0 0.520 NFRC 0.29 1 NFRC 0 New Metal Dual Tint Doors Master Suite 3 Window 52.0 0.280 NFRC 0.26 NFRC 135 New Double Non Metal Tinted Master Suite 4 Window 80.0 0.520 NFRC 0.29 NFRC 180 New Metal Dual Tint Doors Master Suite 5 Window 52.0 0.280 NFRC 0.26 NFRC 225 New Double Non Metal Tinted Master Suite 6 Window 7.0 0.280 NFRC 0.26 NFRC 225 New Double Non Metal Tinted Master Suite 7 Skylight 4.0 0.590 NFRC 0.39 NFRC 270 New Skylight Bdrms 2, 3, 4 & Guest Living 8 Skylight 4.0 0.590 NFRC 0.39 NFRC 270 New Skylight Bdrms 2, 3, 4 & Guest Living 9 Skylight 8.0 0.590 NFRC 0.39 NFRC 270 New Skylight Bdrms 2, 3, 4 & Guest Living 10 Window 60.0 0.520 NFRC 0.29 NFRC 0 New Metal Dual Tint Doors Bdrms 2, 3, 4 & Guest Living 11 Window 7.0 0.280 NFRC 0.26 NFRC 30 New Double Non Metal Tinted Bdrms 2, 3, 4 & Guest Living 12 Window 21.8 0.280 NFRC 0.26 NFRC 30 New Double Non Metal Tinted Bdrms 2, 3, 4 & Guest Living 3 Window 75.0 0.520 NFRC 0.29 NFRC 90 New Metal Dual Tint Doors Bdrms 2, 3, 4 & Guest Living 4 Window 110.0 0.520 NFRC 0.29 NFRC 90 New Metal Dual Tint Doors Bdrms 2, 3, 4 & Guest Living 5 r1ill Window 9.0 0.280NFRC 0.26 NFRC 120 New Double Non Metal Tinted Bdrms 2, 3, 4 & Guest Living 6 Window 7.01 0.280 NFRC 0.26 NFRC 120 New Double Non Metal Tinted Bdrms 2, 3, 4 & Guest Living (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hot Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin Hot Dist Len H t 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 None 1.00 8 None 1.00 9 None 1.00 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 1 0.76 2.0 18.0 12.0 0.1 12.0 12.0 16 JBug Screen 1 0.76 10.0 6.5 12.0 0.1 12.0 12.0 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012.12-20712:34:44 ID: Page 9 of 30 C] 0 • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name The Madison Club Building Type m Single Family ❑ Addition Alone O Multi Family 0 Existing+ Addition/Alteration Date 2120/2012 OPAQUE SURFACE DETAILS Surface T e Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 312 0.069 R-21 300 90 New 4.3.1-A6 Bdrms 2, 3, 4 & Guest Livi Slab 1,050 0.730 None 0 180 New 4.4.7-A1 Bdrms 2, 3, 4 & Guest Livi Slab 390 0.730 None 0 180 New 4.4.7-A1 Bdrms 2, 3, 4 & Guest Livi Roof 3,406 0.026 R-38 270 0 -New 4.2.1-A9 Liv/Off/GreaWibDin Wall 271 0.069 R-21 0 90 New 4.3.1-A6 Liv/0ff/Gmat#Qt1Din Wall 354 0.069 R-21 30 90 New 4.3.1-A6 Liv/Off/GreaWit/Din Door 20 1.450 None 30 90 New 4.5.1-A1 Liv/Off/Great/Kit/Din Wall 30 0.069 R-21 90 90 New 4.3.1-A6 Liv/Off/GreaWit/Din Wall 155 0.069 R-21 105 90 New 4.3.1-A6 Liv/Off/GreaWit/Din Wall 257 0.069 R-21 120 90 New 4.3.1-A6 LiV/Off/GreaWit/Din Wall 60 0.069 R-21 150 90 New 4.3.1-A6 Liv/Off/GreaWit/Din Wall 166 0.069 R-21 180 90 New 4.3.1-A6 Liv/Off/GreatXit/Din Wall 148 0.069.R-21 240 90 New 4.3.1-A6 Liv/Off/GreatlK&Din Wall 96 0.069 R-21 270 90 New 14.3.1-A6 Liv/Off/Great/Kit/Din Wall 252 0.069 R-21 300 90 New 14.3.1-A6 JLWOWGreaWdlDin Slab 508 0.730 None 0 180 New 4.4.7-A1 JLWOfflGreaWitlDin FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 17 Window 35.0 0.520 1 NFRC 0.29 NFRC 180 New Metal Dual Tint Doors Bdrms 2, 3, 4 & Guest Living 18 Window 90.0 0.520 1 NFRC 0.29 NFRC 210 New Metal Dual Tint Doors Bdrms 2, 3, 4 & Guest Living 19 Window 42.0 0.280 NFRC 0.26 NFRC 270 New Double Non Metal Tinted Bdrms 2, 3, 4 & Guest Living_ 20 Window 80.0 0.520 NFRC 0.29 NFRC 300 New Metal Dual Tint Doors Bdrms 2, 3, 4 & Guest Living 21 Window 7.0 0.280 NFRC 0.26 NFRC 300 New Double Non Metal Tinted Bdrms 2, 3, 4 & Guest Living 22 Window 9.0 0.280 NFRC 0.26 NFRC 300 New Double Non Metal Tinted Bdrms 2, 3, 4 & Guest Living 23 Skylight 8.0 0.590 NFRC 0.39 NFRC 270 New Skylight Liv/Off/GreaWit/Din 24 Window 48.0 0.280 NFRC 0.26 NFRC 0 New Double Non Metal Tinted Liv/Off/GreatXit/Din 25 Window 28.0 0.280 NFRC 0.26 NFRC 0 New Double Non Metal Tinted Liv/Off/GreaWit/Din 26 Window 12.0 0.280 NFRC 0.26 NFRC 0 New Double Non Metal Tinted Liv/Off/GreaWit/Din 27 Window 57.5 0.520 NFRC 0.29 NFRC 0 New Metal Dual Tint Doors Liv/Off/GreaWit/Din 28 Window 12.0 0.280 NFRC 0.26 NFRC 0 New Double Non Metal Tinted Liv/Off/GreatXit/Din 29 Window 28.0 0.280 NFRC 0.26 NFRC 0 New Double Non Metal Tinted Liv/Off/GreaWit/Din 30 Window 62.0 0.520 NFRC 0.29 NFRC 30 New Metal Dual Tint Doors Liv/Off/GreaWit/Din 31 Window 105.6 0.280 NFRC 0.26 NFRC 90 New Double Non Metal Tinted Liv/Off/GreaWit/Din 32 Window 97.0 0.520 1 NFRC 0.29 NFRC 105 New Metal Dual Tint Doors Liv/0ff/Great4Gt1Din (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t I Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len I Hot Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 None 1.00 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 JBug Screen 0.76 10.0 10.0 10.0 0.1 10.0 10.0 32 JBug Screen 0.76 10.0 6.0 10.0 0.1 10.0 10.0 �E-n-emyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-12-20712:34:44 ID: Pae 10 of 30 • • • CERTOCATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name The Madison Club Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2120/2012 OPAQUE SURFACE DETAILS Surface U- Insulation T e Area Factor Cavitv Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Slab 2,906 0.730 None 0 180 New 4.4.7-A1 Liv/Off/GreaWit/Din FENESTRATION SURFACE DETAILS ID Tvpe Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 20.0 0.280 NFRC 0.26 NFRC 120 New Double Non Metal Tinted Liv/Off/GreaWit/Din 34 Window 15.8 0.280 NFRC 0.26 NFRC 120 New Double Non Metal Tinted Liv/Off/GreaWit/Din 35 Window 13.5 0.280 NFRC 0.26 NFRC 120 New Double Non Metal Tinted Liv/Off/Great/Kit/Din 36 Window 21.0 0.280 NFRC 0.26 NFRC 150 New Double Non Metal Tinted Liv/Off/Great/Kit/Din 37 Window 110.0 0.520 NFRC 0.29 NFRC 180 New Metal Dual Tint Doors Liv/Off/Great/Kit/Din 38 Window 216.0 0.280 NFRC 0.26 NFRC 180 New Double Non Metal Tinted Liv/Off/Great/Kit/Din 39 Window 50.3 0.280 NFRC 0.26 NFRC 240 New Double Non Metal Tinted Liv/Off/GreaWit/Din 40 Window 78.0 0.520 NFRC 0.29 NFRC 240 New Metal Dual Tint Doors Liv/Off/GreaWit/Din 41 Window 15.2 0.280 NFRC 0.26 NFRC 270 New Double Non Metal Tinted Liv/Off/Great/Kit/Din 42 Window 48.0 0.520 NFRC 0.29 NFRC 270 New Metal Dual Tint Doors Liv/Off/Great/Kit/Din 43 Window 17.6 0.280 NFRC 0.26 NFRC 270 New Double Non Metal Tinted Liv/Off/Great/Kit/Din 44 Window 14.4 0.280 NFRC 0.26 NFRC 270 New Double Non Metal Tinted Liv/Off/Great/Kit/Din 45 Window 140.0 0.520 NFRC 0.29 NFRC 300 New Metal Dual Tint Doors Liv/Off/Great/Kit/Din 46 Window 9.0 0.280 NFRC 0.26 NFRC 300 New Double Non Metal Tinted Liv/Off/GreaWit/Din (1) U -Factor Type: 2 SHGC Typo: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 33 Bug Screen 0.76 10.0 6.0 10.0 0.1 10.0 10.0 34 Bug Screen 0.76 10.0 6.0 10.0 0.1 10.0 10.0 35 Bug Screen 0.76 10.0 6.0 10.0 0.1 10.0 10.0 36 Bug Screen 0.76 10.0 6.0 10.0 0.1 10.0 10.0 37 Bug Screen 0.76 10.0 6.5 10.0 0.1 10.0 10.0 38 Bug Screen 0.76 7.0 8.3 10.0 0.1 10.01 10.0 39 Bug Screen 0.76 10.0 6.0 10.0 0.1 10.01 10.0 40 Bug Screen 0.76 10.0 6.0 10.0 0.1 10.0 10.0 41 IBuo Screen 0.76 Bu Screen 0.76 Bu Screen 0.76 10.0 6.0 10.0 0.1 10.0 10.0 Bu Screen 0.76 10.0 6.0 10.0 0.1 10.0 10.0 r45 Bu Screen 0.76 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2012-12-20712:34:44 ID: Pae 11 of 30 • C7 C] CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF=1 R Project Name The Madison Club Building Type ®Single Family ❑Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11212012012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC 1 Sleeping Space 1,124 12,589 HVAC 2 Sleeping Space 1,440 15,408 HVAC 3,4 & 5 Living Space 3,414 41,651 Totals 5,9781 01 01 0 HVAC SYSTEMS System Name Oty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 2 1 Central Furnace 80% AFUE S lit Air Conditioner 16.0 SEER No Setback New HVAC 3,4 & 5 3 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New :t HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 3,4 & 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 M New WATER HEATING SYSTEMS S stem Name Q T e Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradforf White 75 Gal 2 Small Gas All Pipes Ins 65,000 75 0.66 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ff c 0 m a System Name Pipe Length Pipe Diameter Insul. Thick. Qty.THP Plenum Outside Buried ❑ EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-12-20712:34:44 ID: Pae 12 of 30 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Date The Madison Club 11212012012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Buildina Envelooe Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 4150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent LI -factor. 6150(f): Air retardina wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form. §150(8): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150(e)1A• Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the buildina. are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or RCCA. §150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinQ sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 41500)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in 16150(i)4: Solar water-heatina systems and/or collectors are certified by the Solar Rating and Certification Corporation. •I EnemvPro 5.1 by EnemvSolf User Number: 6712 RunCode: 2012-12-20T12:34:44 ID: Page 13 of 30 C MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date The Madison Club 11212012012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150(m)10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. ' EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-12-20712:34:44 ID: Page 14 of 30 L MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name. Date The Madison Club 11212012012 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within, six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 2012-12-20712:34:44 ID: Page 15 of 30 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date The Madison Club 12/20/2012 System Name Floor Area HVAC 1 1,124 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System Sensible CFM Sensible Latent CFM Output perSystem 71,000 15,823 Total Room Loads 459 13,353 902 365 Total Output Btuh 71,000 Return Vented Lighting 0 Output Btuh/s ft 63.2 778 Return Air Ducts 771 Cooling System 0 Return Fan 0 Output perSystem 58,5001 0 Ventilation 0 0 01 0 Total Output Btuh 58,500 0 Supply Fan 0 Total output ons 4.9 778 Supply Air Ducts 771 Total Output Btuh/s ft 52.0 Total Output s ft/Ton 230.6 1 17,379 TOTAL SYSTEM LOAD 14,8941 9021 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 4Ton 48,130 0 71,000 Airflow cfm/s ft 1.42 Airflow cfm/Ton 328.2 Outside Air % 0.0% Total Adjusted System Output 48,130 0 1 71,000 Outside Air (cfm/ft 0.00(Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK Aug 3 PM I Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF 70 OF 111 OF Outside Air 0 cfm Supply Fan Heating Coil 111 OF 1,600 cfm ROOM 70 of I 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 °F 78160 OF 78 / 60 OF 50 / 49 OF o Outside Air 0 cfm Supply Fan Cooling Coil 1,600 cfm 51 / 49 °F 34.3% ROOM 78/60OF 78/60°F 01 A I � EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2012-12-20T12:34:44 ID: Page 16 of 30 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name The Madison Club Date 12/20/2012 System Name HVAC 2 Floor Area 1,440 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 1,209 25,869 Return Vented Lighting 0 Return Air Ducts 1,493 Return Fan o Ventilation 0 0 Supply Fan 0 Supply Air Ducts 1,493 TOTAL SYSTEM LOAD 28,856 COIL HTG. Latent CFM 1,4991 626 0 0 F 1,499 PEAK Heating System Sensible Output perSystem 89,000 27,016 Total Output Btuh 89,000 Output Btuh/s ft 61.8 1,328 Cooling System 0 Output perSystem 58,500 0 Total Output Btuh 58,500 0 Total Output ons 4.9 1,328 Total Output Stuh/s ft 40.6 Total Output s ft/Ton 295.4 29,672 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Alrflow cfm 2,000 Carrier 5 Ton 45,781 5,304 89,000 Alrf low cfm/s ft 1.39 Total Adjusted System Output 1 45,7811 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 5,304 1 89,000 Aug 3 PM I Jan 1 AM Airflow cfmfTon 410.3 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF Outside Air 0 cfm Supply Fan 2,000 cfm 69 of 69 OF 111 OF Heating Coil 111 OF -•••••• ROOM vIn 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 79/64°F 79/64°F 57/56°F Outside Air 0 cfm Supply Fan Cooling Coil58 / 56 OF _........ .... _.. 2,000 cfm 45.7% ROOM 79/64OF 78/64°F A 4 EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2012-12-20712:34:44 ID: Page 17 of 30 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name The Madison Club Date 12/20/2012 System Name HVAC 3,4 & 5 Floor Area 3,414 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 COIL CFM Total Room Loads 2,601 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 71,000 43,610 2,532 1,254 48,373 Total Output Btuh 213,000 0 Output Btuh/s ft 62.4 2,518 2,377 Cooling System o 0 Output perSystem 47,000 0 0 0 0 Total Output Stuh 141,000 o 2,532 0 Total Output ons 11.8 2,518 2,377 Total Output Btuh/s ft 41.3 Total Output s ft/Ton 290.6 48,645 53,127 Air System CFM perSystem 1,800 HVAC EQUIPMENT SELECTION Airflow cfm 5,400 Carrier Split DX/FAU 95,570 32,879 213,000 Airflow cfm/s ft 1.58 1 213,000 Jan 1 AM Airflow cfm/Ton 459.6 Outside Air % 0.0% Total Adjusted System Output 1 95,570 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 32,879 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 cfm Supply Fan 5,400 cfm 70 of 70 OF Own 107 OF Heating Coil 106 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112178 OF 78 / 66 OF 78167 OF 62 / 61 OF 10 0 Outside Air Ar I 0 cfm Supply Fan Cooling Coil 5,400 cfm 78 / 66 OF 62 / 61 OF 54.6% ROOM 78/ 66 OF EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-12-20712:34:44 ID: Page 18 of 30 • • • ROOM LOAD SUMMARY Project Name Date The Madison Club 12120/2012 System Name Floor Area HVAC 1 1,124 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Master Suite Sleeping Space 1 459 13,353 902 459 13,353 902 365 15,823 PAGE TOTAL TOTAL' Total includes ventilation 459 13,353 902 365 15,823 459 13,3531 902 365 15,8 I EnemyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-12-20712:34:44 ID: Page 19 of 30 1 • 0 • ROOM LOAD SUMMARY Project Name Date The Madison Club 12120/2012 System Name Floor Area HVAC 2 1,440 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Bdrms Z 3, 4 & Guest Livin Sleeping Space 1 1,209 25,869 1,499 1,209 26 169 1,499 6261 27,016 PAGE TOTAL TOTAL' 1,209 25,8691 1,4991 626 27,016 1,209 25,869 1,499 626 27,016 Total includes ventilation load for zonal systems. EnemyPro 5.1 by Enem ySoft User Number.' 6712 RunCode: 2012-12-20712:34:44 ID: Page 20 of 30 • • • ROOM LOAD SUMMARY Project Name Date The Madison Club 12/20/2012 HVAC 3.4 & 5 3,414 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name I Mult. I CFM I Sensible I Latent CFM I Sensible I Latent CFM I Sensible Liv/Off/GreaWit/Din living Space 1 1 2,6011 43,6101 2,532 2,6011 43,6101 2,532 1,2541 48,373 1 for zonal User Ni PAGE TOTAL TOTAL' 2,601 43,610 2,532 1,254 48,373 2,601 43,610 2,532 1,254 48,373 • • • ROOM HEATING PEAK LOADS Project Name The Madison Club ROOM INFORMATION DESIGN CONDITIONS Room Name Sleeping Space Time of Peak Floor Area 1,124.0 R' Outdoor Dry Bulb Temperature Indoor D Bulb Tem erature 70 OF 12/2012012 Jan 1 AM 26 OF Conduction Area U -Value AT OF Btu/hr R-38 Roof Attic 1,111.7 X 0.0260 X 44 = 1,272 Skylight 12.3 X 0.5900 X 44 = 319 R-21 Wall 735.0 X 0.0690 X 44 = 2,231 Metal Dual Tint Doors 220.0 X 0.5200 X 44 = 5,034 Double Non Metal Tinted 111.0 X 0.2800 X 44 = 1,368 Slab -On -Grade perim = 89.0 X 0.7300 X 44 = 2,859 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 13,082 Infiltration:[ 1.00 X 1.064 X 1,124 X 11.20 X 0.279 /60] X 44 = 2,741 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 15,823 5.1 • • • ROOM HEATING PEAK LOADS Project Name Date The Madison Club 12120/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Sleeping Space Time of Peak Jan 1 AM Floor Area 1,440.0 ft2 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr R-38 Roof Attic 1,424.0 X 0.0260 X 44 = 1,629 Skylight 16.0 X 0.5900 X 44 = 415 R-21 Wall 1,345.2 X 0.0690 X 44 = 4,084 Metal Dual Tint Doors 450.0 X 0.5200 X 44 = 10,296 Double Non Metal Tinted 102.8 X 0.2800 X 44 = 1,266 Slab -On -Grade perim = 181.0 X 0.7300 X 44 = 5,814 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 23,505 Infiltration:[ 1.00 X 1.064 X 1,440 X 10.70 X 0.292 /60] X 44 = 3,512 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 27,016 Energ Pro 5.1 by Energ Soft User Number.- 6712 RunCode: 2012-12-20712:34:44 ID: Page 23 of 30 • • • ROOM HEATING PEAK LOADS Project Name Date The Madison Club 12/20/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Space Time of Peak Jan 1 AM Floor Area 3,414.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr R-38 Roof Attic 3,406.0 X 0.0260 X 44 = 3,896 Skylight 8.0 X 0.5900 X 44 = 208 R-21 Wall 1,787.8 X 0.0690 X 44 = 5,428 Double Non Metal Tinted 626.4 X 0.2800 X 44 = 7,717 Metal Dual Tint Doors 592.5 X 0.5200 X 44 = 13,556 Wood Door 20.0 X 1.4500 X 44 = 1,276 Slab -On -Grade perim = 248.0 X 0.7300 X 44 = 7,966 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 40,047 Infiltration:[ 1.00 X 1.064 X 3,414 X 12.20 X 0.256 /60] X 44 = 8,325 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 48,373 Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2012-12-20712:34:44 ID: Page 24 of 30 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Madison Club 1 12120/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Sleeping Space Outdoor Dry Bulb Temperature 112 OF Floor Area 1,124.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OFI Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof Affic (tM 1,111.7 X 0.0260 X 56.0 = 1,619 R-21 Wall (N) , 43.0 X 0.0690 X 23.0 = 68 R-21 Wall (SE) 179.0 X 0.0690 X 31.0 = 383 R-21 Wall (S) 60.0 X 0.0690 X 26.0 = 108 R-21 Wall (SK9 68.01 X 0.0690 X 31.0 = 145 R-21 Wall W 385.0 X 0.0690 X 33.0 = 877 X X = X X = X X = Page Total 1 3,199 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Skylight (W) 0.0 X 26.7 + 12.3 X 79.5 = 978 N (N) 0.0 X 21.2 + 140.0 X 21.2 = 2,963 17 (SE) 0.0 X 15.2 + 52.0 X 21.2 = 1,104 M (S) 0.0 X 21.2 + 80.0 X 21.2 = 1,698 16 (SM 0.0 X 15.2 + 52.0 X 21.2 = 1,104 15 (SM 0.0 X 15.2 + 7.0 X 21.2 = 149 X + X = X + X = X + X = Page Total 7,996 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 )( 0.87 X 61.51 X 34 = 1,927 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,353 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.87 X 61.51 X 0.00276 = 702 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 902 EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2012-12-20T12:34:44 ID: Pa a 25 of 30 0 • RESIDENTIAL ROOM COOLING LOAD SUMMARY The Madison Club 12/20/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Sleeping Space Outdoor Dry Bulb Temperature 112 OF Floor Area 1,440.0 R2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Ananna Surfar_pc R-38 Roof Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-21 Wall Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,424.0 0.0260 56.0 39.0 0.0690 23.0 329.2 0.0690 27.0 167.0 0.0690 33.0 104.0 0.0690 31.7 163.0 0.0690 26.0 97.0 0.0690 29.3 134.0 0.0690 33.0 312.0 0.0690 31.2 Page Total Items shown with an asterisk (•) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded I Fpnpctratinn Skylight Skylight Skylight H 9 7 E C 6 Orientation (tM (►M (tM (N) (NE) (NE) (E) (E) (SE) Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 26.7 4.0 79.5 0.0 26.7 4.0 79.5 0.0 26.7 8.0 79.5 0.0 21.2 60.0 21.2 0.0 15.2 7.0 20.8 0.0 15.2 21.8 20.8 0.0 21.2 75.0 38.4 0.0 21.2 110.0 38.4 9.0 15.2 0.0 21.91 Page Total I Internal Gain 3.0 Occupants X 230 Btuh/occ. 0.0 Dwelling Unit X 1,6001 Btu Infiltration: 1.064 X 0.87 X 78.80 X 34 = Air Sensible CFM ELA AT Btu/hr 62 613 380 227 292 196 305 671 4,821 Btu/hr 318 318 636 1,270 146 454 1 1371 I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25,8691 Latent Gain Occupants 3.0 Occupants X 200 Btuh/occ. Infiltration: 4.771 X 0.87 X 78.80 X 0.00276 = Air Sensible CFM ELA AW Btu/hr 1 8991 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 499 • • C] • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Madison Club 12/20/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Sleeping Space Outdoor Dry Bulb Temperature 112 OF Floor Area 1,440.0 ft' Outdoor Wet Bulb Tem erature p 78 °F Indoor Dry Bulb Temperature 78 OFI Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X X X = X X = X X = X X = X X = X X = Page Total D Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 5 (SE) 7.0 X 15.2 + 0.0 X 21.9 = 107 D (S) 0.0 X 21.2 + 35.0 X 21.2 = 743 F (SM 0.0 X 21.2 + 90.0 X 25.6 = 2,307 11 (IM 0.0 X 15.2 + 42.0 X 30.7 = 1,289 G (NW) 0.0 X 21.2 + 80.0 X 33.1 = 2,649 10 (NIM 0.0 X 15.2 + 7.0 X 26.0 = 182 8 (NIA9 0.0 X 15.2 + 9.0 X 26.0 = 234 X + X = X +1 X = Page Total 7,510 Internal Gain Btu/hr Occupants 3.0 Occupants X 230 Btuh/occ. = 690 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.87 X 78.80 X 34 = 2,469 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25,869 Latent Gain Btu/hr Occupants 3.0 Occupants X 200 Btuh/occ. = 600 Infiltration: 4,771 X 0.87 X 78.80 X 0.00276 = 899 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,499 EnerovPro 5.1 by EneroySoft User Number: 6712 RunCode: 2012-12-20712:34:44 ID: Page 27 of 30 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Madison Club 1 12/20/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Space Outdoor Dry Bulb Temperature 112 OF Floor Area 3,414.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Ooaaue Surfaces R-38 Roof Attic R-21 Wall R-21 Wall Wood Door R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-21 Wall Orientation (NE) (SE) (SE) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 3,406.0 0.0260 56.0 270.5 0.0690 23.0 354.0 0.0690 27.0 20.0 1.4500 27.0 30.4 0.0690 33.0 155.0 0.0690 32.3 256.7 0.0690 31.7 60.0 0.0690 29.3 166.01 0.06901 26.0 15.2 28.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fanastratinn Skylight14 3 2 28 B 28 1 S 4 Orientation (tM (N) (N) (N) (N) (N) (N) (NE) (E) Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 26.7 8.0 79.5 0.0 15.2 48.0 15.2 0.0 15.2 28.0 15.2 0.0 15.2 12.0 15.2 0.0 21.2 57.5 21.2 0.0 15.2 12.0 15.2 0.0 15.2 28.0 15.2 0.0 21.2 62.0 27.4 83.4 15.2 22.2 30.7 Page Total Btu/hr 4,959 429 660 783 69 346 561 121 298 8,226 Btu/hr 636 732 427 183 1,217 183 427 1,697 1,9531 7.455 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460 Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 0.87 X 186.82 X 34 = 5,853 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 43,6101 Latent Gain Btu/hr Occupants 2.0 Occupants X 200 Btuh/occ. = 400 Infiltration: 4.771 X 0.87 X 186.82 X 0.00276 = 2,132 Air Sensible CFM ELA AW C • RESIDENTIAL ROOM COOLING LOAD SUMMARY rrolect rvame The Madison Club ROOM INFORMATION Room Name Floor Area Indoor Dry Bulb Temper; Opaque Surfaces R-21 Wall R-21 Wall R-21 Wall Orientation 12/20/2012 DESIGN CONDITIONS Living Space Outdoor Dry Bulb Temperature 3,414.0 ft2 Outdoor Wet Bulb Temperature 78 OF Outdoor Daily Range: Area X X X X X X X XX Xj U -Factor X X X X X X X X CLTD' = = = = = = = = = 147.7 0.0690 31.7 95.5 0.0690 33.0 252.0 0.0690 31.2 21.9 15.8 15.2 0.0 21.9 13.5 15.2 0.0 21.9 21.0 15.2 0.0 19.3 110.0 21.2 0.0 21.2 216.0 15.2 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fanactratinn 20 23 22 21 19 R P 18 Q Orientation (E) (SE) (SE) (SE) (SE) (S) (S) (S K9 (SM Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 97.0 21.2 0.0 37.4 20.0 15.2 0.0 21.9 15.8 15.2 0.0 21.9 13.5 15.2 0.0 21.9 21.0 15.2 0.0 19.3 110.0 21.2 0.0 21.2 216.0 15.2 0.0 15.3 50.3 15.2 0.0 21.9 78.01 21.2 0.0 28.61 Page Total 112 OF 78 OF 34 OF Btu/hr 323 217 542 1, Btu/hr 2,053 305 241 206 320 2,328 3,294 767 1,6511 11,163 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 )( 0.87 X 186.82 X 34 = 5,853 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 43,6101 Latent Gain Btu/hr Occupants 2.0 Occupants X F Btuh/occ. = 400 Infiltration: 4,771 X 0.87 X 186.82 X 0.00276 = 2,132 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR 0 w • R£SWENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Madison Club 1 12120/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Space Outdoor Dry Bulb Temperature 112 OF Floor Area 3,414.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OFI Outdoor Daily Range: 34 OF .Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X I I X = Page Total 0 Items shown with an asterisk (•) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 14 (W) 0.0 X 15.2 + 15.2 X 30.7 = 466 ,/ (VV) 0.0 X 21.2 + 48.0 X 38.4 = 1,842 13 W 13.9 X 15.2 + 3.7 X 30.7 = 325 12 (VV) 11.4 X 15.2 + 3.0 X 30.7 = 266 Y (NVtq 0.0 X 21.2 + 140.0 X 33.1 = 4,637 27 (NM 0.0 X 15.2 + 9.0 X 26.0 = 234 X + X = X + X = X +1 X = Page Total 7,770 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 186.82 X 34 = 5,853 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 43,610 Latent Gain Btu/hr Occupants 2�0 Occupants X 200 Btuh/occ. _ 400 Infiltration: 4,771 X 0.87 X 186.82 X 0.00276 = 2,132 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,532 EnerovPro 5.1 bv EneravSoft User Number: 6712 RunCode: 2012-12-20712:34:44 ID: Page 30 of 30