12-1348 (SFD) Title 24BUILDING ENERGY ANALYSIS REPORT
PROJECT:
The Madison Club
Lot 54B
La Quinta, Ca 92253
Project Designer:
TDC Associates Design and Drafting
Po Box 1654
.La Quinta, CA 92253
(760) 771-6589
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, Ca 92211
(760) 200-4780�2� ����
CIN OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DA
Job Number:
Date:
12/20/201 ,ptJ 1'12��3
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential an. �onyesidenial 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC -- www.energysoff.com.
1
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
Room Load Summary
Room Heating Peak Loads
Room Cooling Peak Loads
EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 6712
1
2
3
13
16
19
22
25
s
0
W-]
•
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
The Madison Club
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration 11212012012
Date
Project Address
Lot 54B La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,978
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
Roof Wood Framed Attic R-38 5,942 Radiant Barrier New
Wall Wood Framed R-21 3,868 New
Slab Unheated Slab -on -Grade None 5,978 Perim = 518' New
Door Opaque Door None 20 New
FENESTRATION U- Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status
Skylight 12.3 0.590
0.39 none none None New
Front (N) 257.5 0.520
0.29 none none Bug Screen New
Left (SE) 52.0 0.280
0.26 none none Bug Screen New
Rear (S) 115.0 0.520
0.29 none none Bug Screen New
Rear (Std 59.0 0.280
0.26 none none Bug Screen New
Skylight 4.0 0.590
0.39 none none None New
Skylight 4.0 0.590
0.39 none none None New
Skylight 8.0 0.590
0.39 none none None New
Front (NE) 28.8 0.280
0.26 none none Bug Screen New
Left (E) 185.0 0.520
0.29 none none Bug Screen New
Left (SE) 16.0 0.280
0.26 12.0 none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 16.0 SEER Setback
New
1 Central Furnace 80% AFUE
Split Air Conditioner 16.0 SEER No Setback
New
3 Central Furnace 80% AFUE
Split Air Conditioner 16.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC 1 Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
HVAC 2 Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
HVAC 3,4 & 5 Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
2 Small Gas 75
0.66 All Pipes Ins
New
EnergyPry 5.1 by EnergySoft User Number: 6712
RunCode: 2012-12-20712:34:44 ID:
Page 3 of 30
C]
•
•
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
The Madison Club
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration 11212012012
Date
Project Address
Lot 54B La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,978
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status
Rear (SM 90.0 0.520 0.29 none none Bug Screen New
Right (tM 57.2 0.280 0.26 none none Bug Screen New
Right (NIM 220.0 0.520 0.29 none none Bug Screen New
Right (NK9 25.0 0.280 0.26 none none Bug Screen New
Skylight 8.0 0.590 0.39 none none None New
Front (N) 128.0 0.280 0.26 none none Bug Screen New
Front (NE) 62.0 0.520 0.29 none none Bug Screen New
Left (E) 105.6 0.280 0.26 10.0 none Bug Screen New
Left (E) 97.0 0.520 0.29 10.0 none Bug Screen New
Left (SE) 49.3 0.280 0.26 10.0 none Bug Screen New
Rear (SE) 21.0 0.280 0.26 10.0 none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-12-20712:34:44 ID:
Page 4 of 30
•
•
•
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
The Madison Club
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration 11212012012
Date
Project Address
Lot 54B La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,978
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status
Rear (S) 110.0 0.520 0.29 10.0 none Bug Screen New
Rear (S) 216.0 0.280 0.26 10.0 none Bug Screen New
Right (SK9 50.3 0.280 0.26 10.0 none Bug Screen New
Right (SW) 78.0 0.520 0.29 10.0 none Bug Screen New
Right (tM 48.0 0.520 0.29 none none Bug Screen New
Right (Vo 32.0 0.280 0.26 10.0 none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
EnergyPro, 5.1 by EnergySoft User Number.' 6712 RunCode: 2012-12-20712:34:44 ID:
Page 5 of 30
9
•
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
The Madison Club
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
11212012012
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw reuirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass: 731.0 112 Covered Slab Floor, 3.500" thick at Sleeping Space
HIGH MASS Design - Verify Thermal Mass: 393.0 ft2 Exposed Slab Floor, 3.500" thick at Sleeping Space
HIGH MASS Design - Verify Thermal Mass: 1,050.0 ft2 Covered Slab Floor, 3.500" thick at Sleeping Space
HIGH MASS Design - Verify Thermal Mass: 390.0 ft2 Exposed Slab Floor, 3.500" thick at Sleeping Space
The HVAC System HVAC 3, 4 & 5 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must
have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HIGH MASS Design - Verify Thermal Mass: 508.0 ft2 Covered Slab Floor, 3.500" thick at Living Space
HIGH MASS Design - Verify Thermal Mass: 2,906.0 ft2 Exposed Slab Floor, 3.500" thick at Living Space
The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The Cooling System Carrier 4 Ton includes credit for a 12.5 EER Condenser A certified HERS rater must field verity the installation of the correct
Condenser.
The HVAC System HVAC 1 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 1 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC
System.
The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier 5 Ton includes credit for a 12.7 EER Condenser. A certified HERS rater must field verify the installation of the correct
Condenser.
The HVAC System HVAC 2 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 2 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC
System.
The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
The Cooling System Carrier Split DX/FAU includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the
correct Condenser.
The HVAC System HVAC 3, 4 & 5 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
EneMyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2012-12-20712:34:44 ID: Page 6 of 30
•
•
•
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
The Madison Club
Building Type ® Single Family ❑ Addition Alone
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
Date
11212012012
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The HVAC System HVAC 3,4 & 5 incorporates HERS Verified Refrigerant Charge ora Charge Indicator Display.
The HVAC System HVAC 3, 4 & 5 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the
HVAC System.
The HVAC System HVAC 3, 4 & 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that
duct leakage meets the specified criteria.
h—ne—mvPr, 5.1 by EneMySoft User Number 6712 RunCode: 2012-12-20712:34:44 ID: Pae 7 of 30
•
•
•
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type O Single Family ❑ Addition Alone
Date
The Madison Club
I ❑ Multi Family ❑ Existing+ Addition/Alteration
11212012012
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 4.08 6.37 -2.29
Space Cooling 52.45 46.25 6.20
Fans 10.44 12.25 -1.81
Domestic Hot Water 6.10 6.43 -0.33
Pumps 0.00 0.00 0.00
Totals 73.07 71.30 1.77
Percent Better Than Standard: 2.4
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: • (N) 0 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (N) 1,532 476
Fuel Available at Site: Natural Gas (E) 1,397 505
Raised Floor Area: 0 (S) 1,225 611
Slab on Grade Area: 5.978 (VVJ 1,837 511
Average Ceiling Height: 11.7 Roof 5,978 36
Fenestration Average U -Factor: 0.42 TOTAL: 2,139
Average SHGC: 0.28 Fenestration/CFA Ratio: 35.8.%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and comple
Documentation Author
Company Scott Design and Title 24, Inc, 12/20/2012
Address 77-085 Michigan Drive Name Tim Scott
City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone (760) 2004780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company TDC Associates Design and Drafting A
Address Po Box 1654 Name Brian de Coster
City/State/zip La Quinta, CA 92253 Phone (760) 771-6589 Signed License # Date
EnemvPro 5.1 by EnemySoft user Number: 6712 RunCode: 2012-12-20712:34:44 ID: Page 8 of 30
•
•
C]
CERTIFICATE OF COMPLIANCE: Residential
Part 4 of R
Project NameType
Madison Club
"5C!F-I
m Single Family ❑Addition AloneThe
❑ Multi Family ❑ Existing+ Addition/A0/2012
OPAQUE SURFACE DETAILS
Surface
T e Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
1,112
0.026 R-38
270
0 New 4.2.1-A9
Master Suite
Wall
43
0.069 R-21
0
90 New 4.3.1-A6
Master Suite
Wall
179
0.069 R-21
135
90 New 4.3.1-A6
Master Suite
Wall
60
0.069 R-21
180
90 New 4.3.1-A6
Master Suite
Wall
68
0.069 R-21
225
90 New 4.3.1-A6
Master Suite
Wall
385
0.069 R-21
270
90 New 4.3.1-A6
Master Suite
Slab
731
0.730 None
0
180 New 4.4.7-A1
Master Suite
Slab
393
0.730 None
0
180 New 4.4.7-A1
Master Suite
Roof
1,424
0.026 R-38
270
0 New 4.2.1-A9
Bdrms 2, 3, 4 & Guest Livi
Wall
39
0.069 R-21
01
90 New 4.3.1-A6
Bdrms 2, 3, 4 & Guest Livi
Wall
329
0.069 R-21
30
90 New 4.3.1-A6
Bdrms 2, 3, 4 & Guest Livi
Wall
167
0.069 R-21
90
90 New 4.3.1-A6
Bdrms 2, 3, 4 & Guest Livi
Wall
104
0.069 R-21
120
90 New 4.3.1-A6
Bdrms 2, 3, 4 & Guest Livi
Wall
163
0.069 R-21
180
90 New 4.3.1-A6
Bdrms 2, 3, 4 & Guest Livi
Wall
97
0.069 R-21
210
90 New 4.3.1-A6
Bdrms 2, 3, 4 & Guest Livi
Wall
134
0.069 R-21
270
90 1 New 14.3.1-A6
18dryns 2, 3, 4 & Guest Livi
FENESTRATION SURFACE DETAILS
ID
Tvpe
Area U -Factor
SHGC
Azm Status
Glazing Type
Location/Comments
1
Skylight
12.3 0.590 NFRC
0.39 1 NFRC 270 New
Skylight
Master Suite
2
Window
140.0 0.520 NFRC
0.29 1 NFRC 0 New
Metal Dual Tint Doors
Master Suite
3
Window
52.0 0.280 NFRC
0.26 NFRC 135 New
Double Non Metal Tinted
Master Suite
4
Window
80.0 0.520 NFRC
0.29 NFRC 180 New
Metal Dual Tint Doors
Master Suite
5
Window
52.0 0.280 NFRC
0.26 NFRC 225 New
Double Non Metal Tinted
Master Suite
6
Window
7.0 0.280 NFRC
0.26 NFRC 225 New
Double Non Metal Tinted
Master Suite
7
Skylight
4.0 0.590 NFRC
0.39 NFRC 270 New
Skylight
Bdrms 2, 3, 4 & Guest Living
8
Skylight
4.0 0.590 NFRC
0.39 NFRC 270 New
Skylight
Bdrms 2, 3, 4 & Guest Living
9
Skylight
8.0 0.590 NFRC
0.39 NFRC 270 New
Skylight
Bdrms 2, 3, 4 & Guest Living
10
Window
60.0 0.520 NFRC
0.29 NFRC 0 New
Metal Dual Tint Doors
Bdrms 2, 3, 4 & Guest Living
11
Window
7.0 0.280 NFRC
0.26 NFRC 30 New
Double Non Metal Tinted
Bdrms 2, 3, 4 & Guest Living
12
Window
21.8 0.280 NFRC
0.26 NFRC 30 New
Double Non Metal Tinted
Bdrms 2, 3, 4 & Guest Living
3
Window
75.0 0.520 NFRC
0.29 NFRC 90 New
Metal Dual Tint Doors
Bdrms 2, 3, 4 & Guest Living
4
Window
110.0 0.520 NFRC
0.29 NFRC 90 New
Metal Dual Tint Doors
Bdrms 2, 3, 4 & Guest Living
5
r1ill
Window
9.0 0.280NFRC
0.26 NFRC 120 New
Double Non Metal Tinted
Bdrms 2, 3, 4 & Guest Living
6
Window
7.01 0.280 NFRC
0.26 NFRC 120 New
Double Non Metal Tinted
Bdrms 2, 3, 4 & Guest Living
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
Hot Wd
Ove hang Left Fin
Len H t LExt RExt Dist Len
Right Fin
Hot Dist Len H t
1
None
1.00
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
None
1.00
8
None
1.00
9
None
1.00
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
1 0.76
2.0 18.0 12.0 0.1 12.0 12.0
16
JBug Screen
1 0.76
10.0 6.5 12.0 0.1 12.0 12.0
EnergyPro
5.1 by EnergySoft User Number: 6712
RunCode: 2012.12-20712:34:44 ID:
Page 9 of 30
C]
0
•
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
The Madison Club
Building Type m Single Family ❑ Addition Alone
O Multi Family 0 Existing+ Addition/Alteration
Date
2120/2012
OPAQUE SURFACE DETAILS
Surface
T e Area
U- Insulation
Factor Cavity Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Wall
312
0.069 R-21
300
90 New 4.3.1-A6
Bdrms 2, 3, 4 & Guest Livi
Slab
1,050
0.730 None
0
180 New 4.4.7-A1
Bdrms 2, 3, 4 & Guest Livi
Slab
390
0.730 None
0
180 New 4.4.7-A1
Bdrms 2, 3, 4 & Guest Livi
Roof
3,406
0.026 R-38
270
0 -New 4.2.1-A9
Liv/Off/GreaWibDin
Wall
271
0.069 R-21
0
90 New 4.3.1-A6
Liv/0ff/Gmat#Qt1Din
Wall
354
0.069 R-21
30
90 New 4.3.1-A6
Liv/Off/GreaWit/Din
Door
20
1.450 None
30
90 New 4.5.1-A1
Liv/Off/Great/Kit/Din
Wall
30
0.069 R-21
90
90 New 4.3.1-A6
Liv/Off/GreaWit/Din
Wall
155
0.069 R-21
105
90 New 4.3.1-A6
Liv/Off/GreaWit/Din
Wall
257
0.069 R-21
120
90 New 4.3.1-A6
LiV/Off/GreaWit/Din
Wall
60
0.069 R-21
150
90 New 4.3.1-A6
Liv/Off/GreaWit/Din
Wall
166
0.069 R-21
180
90 New 4.3.1-A6
Liv/Off/GreatXit/Din
Wall
148
0.069.R-21
240
90 New 4.3.1-A6
Liv/Off/GreatlK&Din
Wall
96
0.069 R-21
270
90 New 14.3.1-A6
Liv/Off/Great/Kit/Din
Wall
252
0.069 R-21
300
90 New 14.3.1-A6
JLWOWGreaWdlDin
Slab
508
0.730 None
0
180 New 4.4.7-A1
JLWOfflGreaWitlDin
FENESTRATION SURFACE DETAILS
ID
Type
Area LI -Factor'
SHGC
Azm Status
Glazing Type
Location/Comments
17
Window
35.0 0.520 1 NFRC
0.29 NFRC 180 New
Metal Dual Tint Doors
Bdrms 2, 3, 4 & Guest Living
18
Window
90.0 0.520 1 NFRC
0.29 NFRC 210 New
Metal Dual Tint Doors
Bdrms 2, 3, 4 & Guest Living
19
Window
42.0 0.280 NFRC
0.26 NFRC 270 New
Double Non Metal Tinted
Bdrms 2, 3, 4 & Guest Living_
20
Window
80.0 0.520 NFRC
0.29 NFRC 300 New
Metal Dual Tint Doors
Bdrms 2, 3, 4 & Guest Living
21
Window
7.0 0.280 NFRC
0.26 NFRC 300 New
Double Non Metal Tinted
Bdrms 2, 3, 4 & Guest Living
22
Window
9.0 0.280 NFRC
0.26 NFRC 300 New
Double Non Metal Tinted
Bdrms 2, 3, 4 & Guest Living
23
Skylight
8.0 0.590 NFRC
0.39 NFRC 270 New
Skylight
Liv/Off/GreaWit/Din
24
Window
48.0 0.280 NFRC
0.26 NFRC 0 New
Double Non Metal Tinted
Liv/Off/GreatXit/Din
25
Window
28.0 0.280 NFRC
0.26 NFRC 0 New
Double Non Metal Tinted
Liv/Off/GreaWit/Din
26
Window
12.0 0.280 NFRC
0.26 NFRC 0 New
Double Non Metal Tinted
Liv/Off/GreaWit/Din
27
Window
57.5 0.520 NFRC
0.29 NFRC 0 New
Metal Dual Tint Doors
Liv/Off/GreaWit/Din
28
Window
12.0 0.280 NFRC
0.26 NFRC 0 New
Double Non Metal Tinted
Liv/Off/GreatXit/Din
29
Window
28.0 0.280 NFRC
0.26 NFRC 0 New
Double Non Metal Tinted
Liv/Off/GreaWit/Din
30
Window
62.0 0.520 NFRC
0.29 NFRC 30 New
Metal Dual Tint Doors
Liv/Off/GreaWit/Din
31
Window
105.6 0.280 NFRC
0.26 NFRC 90 New
Double Non Metal Tinted
Liv/Off/GreaWit/Din
32
Window
97.0 0.520 1 NFRC
0.29 NFRC 105 New
Metal Dual Tint Doors
Liv/0ff/Great4Gt1Din
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t I Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len I Hot Dist Len H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
None
1.00
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
31
JBug Screen
0.76
10.0 10.0 10.0 0.1
10.0 10.0
32
JBug Screen
0.76
10.0 6.0 10.0 0.1
10.0 10.0
�E-n-emyPro
5.1 by EnergySoft User Number: 6712
RunCode: 2012-12-20712:34:44 ID:
Pae 10 of 30
•
•
•
CERTOCATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
The Madison Club
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
2120/2012
OPAQUE SURFACE DETAILS
Surface U- Insulation
T e Area Factor Cavitv Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Slab
2,906 0.730 None
0
180 New 4.4.7-A1
Liv/Off/GreaWit/Din
FENESTRATION SURFACE DETAILS
ID
Tvpe Area
U -Factor
SHGC
Azm Status Glazing Type
Location/Comments
33
Window 20.0
0.280 NFRC
0.26 NFRC 120 New
Double Non Metal Tinted
Liv/Off/GreaWit/Din
34
Window 15.8
0.280 NFRC
0.26 NFRC 120 New
Double Non Metal Tinted
Liv/Off/GreaWit/Din
35
Window 13.5
0.280 NFRC
0.26 NFRC 120 New
Double Non Metal Tinted
Liv/Off/Great/Kit/Din
36
Window 21.0
0.280 NFRC
0.26 NFRC 150 New
Double Non Metal Tinted
Liv/Off/Great/Kit/Din
37
Window 110.0
0.520 NFRC
0.29 NFRC 180 New
Metal Dual Tint Doors
Liv/Off/Great/Kit/Din
38
Window 216.0
0.280 NFRC
0.26 NFRC 180 New
Double Non Metal Tinted
Liv/Off/Great/Kit/Din
39
Window 50.3
0.280 NFRC
0.26 NFRC 240 New
Double Non Metal Tinted
Liv/Off/GreaWit/Din
40
Window 78.0
0.520 NFRC
0.29 NFRC 240 New
Metal Dual Tint Doors
Liv/Off/GreaWit/Din
41
Window 15.2
0.280 NFRC
0.26 NFRC 270 New
Double Non Metal Tinted
Liv/Off/Great/Kit/Din
42
Window 48.0
0.520 NFRC
0.29 NFRC 270 New
Metal Dual Tint Doors
Liv/Off/Great/Kit/Din
43
Window 17.6
0.280 NFRC
0.26 NFRC 270 New
Double Non Metal Tinted
Liv/Off/Great/Kit/Din
44
Window 14.4
0.280 NFRC
0.26 NFRC 270 New
Double Non Metal Tinted
Liv/Off/Great/Kit/Din
45
Window 140.0
0.520 NFRC
0.29 NFRC 300 New
Metal Dual Tint Doors
Liv/Off/Great/Kit/Din
46
Window 9.0
0.280 NFRC
0.26 NFRC 300 New
Double Non Metal Tinted
Liv/Off/GreaWit/Din
(1) U -Factor Type:
2 SHGC Typo:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
H t Wd
Ove hang Left Fin
Len H t LExt RExt Dist Len
Right Fin
H t Dist Len H t
33
Bug Screen
0.76
10.0 6.0 10.0 0.1
10.0 10.0
34
Bug Screen
0.76
10.0 6.0 10.0 0.1
10.0 10.0
35
Bug Screen
0.76
10.0 6.0 10.0 0.1
10.0 10.0
36
Bug Screen
0.76
10.0 6.0 10.0 0.1
10.0 10.0
37
Bug Screen
0.76
10.0 6.5 10.0 0.1
10.0 10.0
38
Bug Screen
0.76
7.0 8.3 10.0 0.1
10.01 10.0
39
Bug Screen
0.76
10.0 6.0 10.0 0.1
10.01 10.0
40
Bug Screen
0.76
10.0 6.0 10.0 0.1
10.0 10.0
41
IBuo Screen
0.76
Bu Screen
0.76
Bu Screen
0.76
10.0 6.0 10.0 0.1
10.0 10.0
Bu Screen
0.76
10.0 6.0 10.0 0.1
10.0 10.0
r45
Bu Screen
0.76
Bug Screen
0.76
EnergyPro
5.1 by EnergySoft User Number. 6712
RunCode: 2012-12-20712:34:44 ID:
Pae 11 of 30
•
C7
C]
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF=1 R
Project Name
The Madison Club
Building Type ®Single Family ❑Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
11212012012
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existing Altered Removed Volume Year Built
HVAC 1 Sleeping Space
1,124
12,589
HVAC 2 Sleeping Space
1,440
15,408
HVAC 3,4 & 5 Living Space
3,414
41,651
Totals 5,9781 01 01 0
HVAC SYSTEMS
System Name Oty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC 1 1 Central Furnace
80% AFUE Split Air Conditioner 16.0 SEER Setback
New
HVAC 2 1 Central Furnace
80% AFUE S lit Air Conditioner 16.0 SEER No Setback
New
HVAC 3,4 & 5 3 Central Furnace
80% AFUE Split Air Conditioner 16.0 SEER Setback
New
:t
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0
m New
HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0
m New
HVAC 3,4 & 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0
M New
WATER HEATING SYSTEMS
S stem Name
Q
T e
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Bradforf White 75 Gal
2
Small Gas
All Pipes Ins
65,000
75
0.66
n/a
n/a
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
ff
c
0
m
a
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty.THP
Plenum Outside Buried
❑
EnergyPro 5.1 by EnergySoft User Number: 6712
RunCode: 2012-12-20712:34:44 ID:
Pae 12 of 30
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name Date
The Madison Club 11212012012
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Buildina Envelooe Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
4150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent LI -factor.
6150(f): Air retardina wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form.
§150(8): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150(e)1A• Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible operable and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the buildina. are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
§150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or RCCA.
§150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculatinQ sections of hot water pipes are insulated per Standards Table 150-13.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
41500)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
16150(i)4: Solar water-heatina systems and/or collectors are certified by the Solar Rating and Certification Corporation.
•I
EnemvPro 5.1 by EnemvSolf User Number: 6712 RunCode: 2012-12-20T12:34:44 ID: Page 13 of 30
C
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
The Madison Club
11212012012
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
§150(m)10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 .
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
' EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-12-20712:34:44 ID: Page 14 of 30
L
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name.
Date
The Madison Club
11212012012
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within, six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 2012-12-20712:34:44 ID: Page 15 of 30
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
The Madison Club
12/20/2012
System Name
Floor Area
HVAC 1
1,124
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
CFM
Sensible
Latent CFM
Output perSystem
71,000
15,823
Total Room Loads 459
13,353
902 365
Total Output Btuh
71,000
Return Vented Lighting
0
Output Btuh/s ft
63.2
778
Return Air Ducts
771
Cooling System
0
Return Fan
0
Output perSystem
58,5001
0
Ventilation 0
0
01 0
Total Output Btuh
58,500
0
Supply Fan
0
Total output ons
4.9
778
Supply Air Ducts
771
Total Output Btuh/s ft
52.0
Total Output s ft/Ton
230.6
1 17,379
TOTAL SYSTEM LOAD 14,8941
9021
Air System
CFM perSystem
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
1,600
Carrier 4Ton
48,130
0 71,000
Airflow cfm/s ft
1.42
Airflow cfm/Ton
328.2
Outside Air %
0.0%
Total Adjusted System Output
48,130
0 1 71,000
Outside Air (cfm/ft
0.00(Adjusted
for Peak Design conditions)
Note: values above given at ARI conditions
TIME OF SYSTEM PEAK
Aug 3 PM I Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF 70 OF
70 OF 111 OF
Outside Air
0 cfm Supply Fan
Heating Coil
111 OF
1,600 cfm
ROOM
70 of
I
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling
Peak
112 / 78 °F 78160
OF 78 / 60 OF 50 / 49 OF
o
Outside Air
0 cfm
Supply Fan Cooling Coil
1,600 cfm
51 / 49 °F
34.3% ROOM
78/60OF
78/60°F
01
A I
�
EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2012-12-20T12:34:44
ID:
Page 16 of 30
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
The Madison Club
Date
12/20/2012
System Name
HVAC 2
Floor Area
1,440
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING PEAK
CFM Sensible
Total Room Loads 1,209 25,869
Return Vented Lighting 0
Return Air Ducts 1,493
Return Fan o
Ventilation 0 0
Supply Fan 0
Supply Air Ducts 1,493
TOTAL SYSTEM LOAD 28,856
COIL HTG.
Latent CFM
1,4991 626
0 0
F 1,499
PEAK
Heating System
Sensible
Output perSystem 89,000
27,016
Total Output Btuh 89,000
Output Btuh/s ft 61.8
1,328
Cooling System
0
Output perSystem 58,500
0
Total Output Btuh 58,500
0
Total Output ons 4.9
1,328
Total Output Stuh/s ft 40.6
Total Output s ft/Ton 295.4
29,672
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Alrflow cfm
2,000
Carrier 5 Ton 45,781
5,304
89,000
Alrf low cfm/s ft
1.39
Total Adjusted System Output 1 45,7811
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
5,304 1 89,000
Aug 3 PM I Jan 1 AM
Airflow cfmfTon 410.3
Outside Air % 0.0%
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 69 OF
Outside Air
0 cfm Supply Fan
2,000 cfm
69 of
69 OF 111 OF
Heating Coil
111 OF
-••••••
ROOM vIn
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 79/64°F 79/64°F 57/56°F
Outside Air
0 cfm Supply Fan Cooling Coil58 / 56 OF
_........ .... _..
2,000 cfm 45.7% ROOM
79/64OF 78/64°F
A 4
EnergyPro5.1 by EnergySoft
User Number: 6712 RunCode: 2012-12-20712:34:44 ID:
Page 17 of 30
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
The Madison Club
Date
12/20/2012
System Name
HVAC 3,4 & 5
Floor Area
3,414
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
3
COIL
CFM
Total Room Loads 2,601
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 71,000
43,610
2,532 1,254
48,373
Total Output Btuh 213,000
0
Output Btuh/s ft 62.4
2,518
2,377
Cooling System
o
0
Output perSystem 47,000
0
0 0
0
Total Output Stuh 141,000
o
2,532
0
Total Output ons 11.8
2,518
2,377
Total Output Btuh/s ft 41.3
Total Output s ft/Ton 290.6
48,645
53,127
Air System
CFM perSystem
1,800
HVAC EQUIPMENT SELECTION
Airflow cfm
5,400
Carrier Split DX/FAU
95,570
32,879
213,000
Airflow cfm/s ft
1.58
1 213,000
Jan 1 AM
Airflow cfm/Ton 459.6
Outside Air % 0.0%
Total Adjusted System Output 1 95,570
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK
32,879
Aug 3 PM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF 70 OF
Outside Air
0 cfm Supply Fan
5,400 cfm
70 of
70 OF Own 107 OF
Heating Coil
106 OF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112178 OF 78 / 66 OF 78167 OF 62 / 61 OF
10 0
Outside Air Ar I
0 cfm Supply Fan Cooling Coil
5,400 cfm
78 / 66 OF
62 / 61 OF
54.6% ROOM
78/ 66 OF
EnergyPro 5.1 by EnergySoR
User Number: 6712 RunCode: 2012-12-20712:34:44
ID:
Page 18 of 30
•
•
•
ROOM LOAD SUMMARY
Project Name Date
The Madison Club 12120/2012
System Name Floor Area
HVAC 1 1,124
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Master Suite Sleeping Space 1 459 13,353 902 459 13,353 902 365 15,823
PAGE TOTAL
TOTAL'
Total includes ventilation
459 13,353
902
365
15,823
459 13,3531
902
365
15,8 I
EnemyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-12-20712:34:44 ID: Page 19 of 30 1
•
0
•
ROOM LOAD SUMMARY
Project Name Date
The Madison Club 12120/2012
System Name Floor Area
HVAC 2 1,440
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Bdrms Z 3, 4 & Guest Livin Sleeping Space 1 1,209 25,869 1,499 1,209 26 169 1,499 6261 27,016
PAGE TOTAL
TOTAL'
1,209
25,8691
1,4991
626 27,016
1,209
25,869
1,499
626 27,016
Total includes ventilation load for zonal systems.
EnemyPro 5.1 by Enem
ySoft User Number.' 6712 RunCode: 2012-12-20712:34:44 ID: Page 20 of 30
•
•
•
ROOM LOAD SUMMARY
Project Name Date
The Madison Club 12/20/2012
HVAC 3.4 & 5
3,414
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name I Mult. I CFM I Sensible I Latent CFM I Sensible I Latent CFM I Sensible
Liv/Off/GreaWit/Din living Space 1 1 2,6011 43,6101 2,532 2,6011 43,6101 2,532 1,2541 48,373
1
for zonal
User Ni
PAGE TOTAL
TOTAL'
2,601 43,610
2,532
1,254
48,373
2,601 43,610
2,532
1,254
48,373
•
•
•
ROOM HEATING PEAK LOADS
Project Name
The Madison Club
ROOM INFORMATION DESIGN CONDITIONS
Room Name Sleeping Space Time of Peak
Floor Area 1,124.0 R' Outdoor Dry Bulb Temperature
Indoor D Bulb Tem erature 70 OF
12/2012012
Jan 1 AM
26 OF
Conduction
Area U -Value
AT OF
Btu/hr
R-38 Roof Attic
1,111.7
X
0.0260
X
44
=
1,272
Skylight
12.3
X
0.5900
X
44
=
319
R-21 Wall
735.0
X
0.0690
X
44
=
2,231
Metal Dual Tint Doors
220.0
X
0.5200
X
44
=
5,034
Double Non Metal Tinted
111.0
X
0.2800
X
44
=
1,368
Slab -On -Grade
perim = 89.0
X
0.7300
X
44
=
2,859
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Items shown with an asterisk (') denote conduction through an interior surface to another room
Page Total
13,082
Infiltration:[ 1.00 X 1.064
X 1,124 X 11.20
X 0.279
/60] X 44
= 2,741
Schedule Air Sensible
Area Ceiling Height
ACH
AT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM
15,823
5.1
•
•
•
ROOM HEATING PEAK LOADS
Project Name
Date
The Madison Club
12120/2012
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Sleeping Space
Time of Peak
Jan 1 AM
Floor Area
1,440.0 ft2
Outdoor Dry Bulb Temperature
26 OF
Indoor Dry Bulb Temperature
70 OF
Conduction
Area U -Value
AT OF
Btu/hr
R-38 Roof Attic
1,424.0 X 0.0260 X
44 =
1,629
Skylight
16.0 X 0.5900 X
44 =
415
R-21 Wall
1,345.2 X 0.0690 X
44 =
4,084
Metal Dual Tint Doors
450.0 X 0.5200 X
44 =
10,296
Double Non Metal Tinted
102.8 X 0.2800 X
44 =
1,266
Slab -On -Grade
perim = 181.0 X 0.7300 X
44 =
5,814
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
Items shown with an asterisk (') denote conduction through
an interior surface to another room
Page Total
23,505
Infiltration:[ 1.00 X 1.064 X
1,440 X 10.70 X 0.292
/60] X 44 =
3,512
Schedule Air Sensible
Area Ceiling Height ACH
AT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM
27,016
Energ Pro 5.1 by Energ Soft User Number.- 6712
RunCode: 2012-12-20712:34:44 ID:
Page 23 of 30
•
•
•
ROOM HEATING PEAK LOADS
Project Name
Date
The Madison Club
12/20/2012
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Living Space
Time of Peak
Jan 1 AM
Floor Area
3,414.0 ft'
Outdoor Dry Bulb Temperature
26 OF
Indoor Dry Bulb Temperature
70 OF
Conduction
Area
U -Value
AT OF
Btu/hr
R-38 Roof Attic
3,406.0
X 0.0260
X
44 =
3,896
Skylight
8.0
X 0.5900
X
44 =
208
R-21 Wall
1,787.8
X 0.0690
X
44 =
5,428
Double Non Metal Tinted
626.4
X 0.2800
X
44 =
7,717
Metal Dual Tint Doors
592.5
X 0.5200
X
44 =
13,556
Wood Door
20.0
X 1.4500
X
44 =
1,276
Slab -On -Grade
perim = 248.0
X 0.7300
X
44 =
7,966
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Items shown with an asterisk (') denote conduction through an interior surface to another room
Page Total
40,047
Infiltration:[ 1.00 X 1.064
X 3,414 X 12.20 X 0.256
/60] X 44
= 8,325
Schedule Air Sensible
Area
Ceiling Height ACH
AT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM
48,373
Energ Pro 5.1 by Energ Soft User Number: 6712
RunCode: 2012-12-20712:34:44
ID:
Page 24 of 30
•
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
The Madison Club
1 12120/2012
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Sleeping Space
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,124.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 78 OFI
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof Affic
(tM 1,111.7 X 0.0260
X
56.0 =
1,619
R-21 Wall
(N) , 43.0 X 0.0690
X
23.0 =
68
R-21 Wall
(SE) 179.0 X 0.0690
X
31.0 =
383
R-21 Wall
(S) 60.0 X 0.0690
X
26.0 =
108
R-21 Wall
(SK9 68.01 X 0.0690
X
31.0 =
145
R-21 Wall
W 385.0 X 0.0690
X
33.0 =
877
X
X
=
X
X
=
X
X
=
Page Total
1 3,199
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
Skylight
(W) 0.0 X 26.7 +
12.3 X
79.5
= 978
N
(N) 0.0 X 21.2 +
140.0 X
21.2
= 2,963
17
(SE) 0.0 X 15.2 +
52.0 X
21.2
= 1,104
M
(S) 0.0 X 21.2 +
80.0 X
21.2
= 1,698
16
(SM 0.0 X 15.2 +
52.0 X
21.2
= 1,104
15
(SM 0.0 X 15.2 +
7.0 X
21.2
= 149
X +
X
=
X +
X
=
X +
X
=
Page Total
7,996
Internal Gain
Btu/hr
Occupants
1.0 Occupants X 230
Btuh/occ.
=
230
Equipment
0.0 Dwelling Unit X 1,600
Btu
=
0
Infiltration: 1.064
)( 0.87 X 61.51 X 34 =
1,927
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
13,353
Latent Gain
Btu/hr
Occupants
1.0 Occupants X 200
Btuh/occ.
=
200
Infiltration: 4,771
X 0.87 X 61.51 X 0.00276 =
702
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
902
EnemvPro 5.1 by EnemySoft
User Number: 6712 RunCode: 2012-12-20T12:34:44 ID:
Pa a 25 of 30
0
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
The Madison Club 12/20/2012
ROOM INFORMATION DESIGN CONDITIONS
Room Name Sleeping Space Outdoor Dry Bulb Temperature 112 OF
Floor Area 1,440.0 R2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF
Ananna Surfar_pc
R-38 Roof Attic
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
1,424.0
0.0260
56.0
39.0
0.0690
23.0
329.2
0.0690
27.0
167.0
0.0690
33.0
104.0
0.0690
31.7
163.0
0.0690
26.0
97.0
0.0690
29.3
134.0
0.0690
33.0
312.0
0.0690
31.2
Page Total
Items shown with an asterisk (•) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
I Fpnpctratinn
Skylight
Skylight
Skylight
H
9
7
E
C
6
Orientation
(tM
(►M
(tM
(N)
(NE)
(NE)
(E)
(E)
(SE)
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
26.7
4.0
79.5
0.0
26.7
4.0
79.5
0.0
26.7
8.0
79.5
0.0
21.2
60.0
21.2
0.0
15.2
7.0
20.8
0.0
15.2
21.8
20.8
0.0
21.2
75.0
38.4
0.0
21.2
110.0
38.4
9.0
15.2
0.0
21.91
Page Total
I Internal Gain
3.0 Occupants X 230 Btuh/occ.
0.0 Dwelling Unit X 1,6001 Btu
Infiltration: 1.064 X 0.87 X 78.80 X 34 =
Air Sensible CFM ELA AT
Btu/hr
62
613
380
227
292
196
305
671
4,821
Btu/hr
318
318
636
1,270
146
454
1 1371
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25,8691
Latent Gain
Occupants 3.0 Occupants X 200 Btuh/occ.
Infiltration: 4.771 X 0.87 X 78.80 X 0.00276 =
Air Sensible CFM ELA AW
Btu/hr
1 8991
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 499
•
•
C]
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
The Madison Club
12/20/2012
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Sleeping Space
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,440.0 ft'
Outdoor Wet Bulb Tem erature
p
78 °F
Indoor Dry Bulb Temperature 78 OFI
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area
U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
D
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area
GLF Area GLF
Btu/hr
5
(SE)
7.0 X 15.2 +
0.0 X
21.9 =
107
D
(S)
0.0 X 21.2 +
35.0 X
21.2 =
743
F
(SM
0.0 X 21.2 +
90.0 X
25.6 =
2,307
11
(IM
0.0 X 15.2 +
42.0 X
30.7 =
1,289
G
(NW)
0.0 X 21.2 +
80.0 X
33.1 =
2,649
10
(NIM
0.0 X 15.2 +
7.0 X
26.0 =
182
8
(NIA9
0.0 X 15.2 +
9.0 X
26.0 =
234
X +
X
=
X +1
X
=
Page Total
7,510
Internal Gain
Btu/hr
Occupants
3.0 Occupants X
230
Btuh/occ.
=
690
Equipment
0.0 Dwelling Unit X
1,600
Btu
=
0
Infiltration: 1.064
X 0.87 X 78.80 X 34 =
2,469
Air Sensible
CFM ELA
AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
25,869
Latent Gain
Btu/hr
Occupants
3.0 Occupants X 200
Btuh/occ.
=
600
Infiltration: 4,771
X 0.87 X 78.80 X 0.00276 =
899
Air Sensible
CFM ELA
AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,499
EnerovPro 5.1 by EneroySoft
User Number: 6712 RunCode: 2012-12-20712:34:44 ID:
Page 27 of 30
•
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
The Madison Club 1 12/20/2012
ROOM INFORMATION DESIGN CONDITIONS
Room Name Living Space Outdoor Dry Bulb Temperature 112 OF
Floor Area 3,414.0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF
Ooaaue Surfaces
R-38 Roof Attic
R-21 Wall
R-21 Wall
Wood Door
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
Orientation
(NE)
(SE)
(SE)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
3,406.0
0.0260
56.0
270.5
0.0690
23.0
354.0
0.0690
27.0
20.0
1.4500
27.0
30.4
0.0690
33.0
155.0
0.0690
32.3
256.7
0.0690
31.7
60.0
0.0690
29.3
166.01
0.06901
26.0
15.2
28.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fanastratinn
Skylight14
3
2
28
B
28
1
S
4
Orientation
(tM
(N)
(N)
(N)
(N)
(N)
(N)
(NE)
(E)
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
26.7
8.0
79.5
0.0
15.2
48.0
15.2
0.0
15.2
28.0
15.2
0.0
15.2
12.0
15.2
0.0
21.2
57.5
21.2
0.0
15.2
12.0
15.2
0.0
15.2
28.0
15.2
0.0
21.2
62.0
27.4
83.4
15.2
22.2
30.7
Page Total
Btu/hr
4,959
429
660
783
69
346
561
121
298
8,226
Btu/hr
636
732
427
183
1,217
183
427
1,697
1,9531
7.455
Internal Gain Btu/hr
Occupants 2.0 Occupants X 230 Btuh/occ. = 460
Equipment 1.0 Dwelling Unit X 1,600 Btu
Infiltration: 1.064 X 0.87 X 186.82 X 34 = 5,853
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 43,6101
Latent Gain Btu/hr
Occupants 2.0 Occupants X 200 Btuh/occ. = 400
Infiltration: 4.771 X 0.87 X 186.82 X 0.00276 = 2,132
Air Sensible CFM ELA AW
C
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
rrolect rvame
The Madison Club
ROOM INFORMATION
Room Name
Floor Area
Indoor Dry Bulb Temper;
Opaque Surfaces
R-21 Wall
R-21 Wall
R-21 Wall
Orientation
12/20/2012
DESIGN CONDITIONS
Living Space Outdoor Dry Bulb Temperature
3,414.0 ft2 Outdoor Wet Bulb Temperature
78 OF Outdoor Daily Range:
Area
X
X
X
X
X
X
X
XX
Xj
U -Factor
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
147.7
0.0690
31.7
95.5
0.0690
33.0
252.0
0.0690
31.2
21.9
15.8
15.2
0.0
21.9
13.5
15.2
0.0
21.9
21.0
15.2
0.0
19.3
110.0
21.2
0.0
21.2
216.0
15.2
0.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fanactratinn
20
23
22
21
19
R
P
18
Q
Orientation
(E)
(SE)
(SE)
(SE)
(SE)
(S)
(S)
(S K9
(SM
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
97.0
21.2
0.0
37.4
20.0
15.2
0.0
21.9
15.8
15.2
0.0
21.9
13.5
15.2
0.0
21.9
21.0
15.2
0.0
19.3
110.0
21.2
0.0
21.2
216.0
15.2
0.0
15.3
50.3
15.2
0.0
21.9
78.01
21.2
0.0
28.61
Page Total
112 OF
78 OF
34 OF
Btu/hr
323
217
542
1,
Btu/hr
2,053
305
241
206
320
2,328
3,294
767
1,6511
11,163
Internal Gain Btu/hr
Occupants 2.0 Occupants X 230 Btuh/occ. = 460
Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600
Infiltration: 1.064 )( 0.87 X 186.82 X 34 = 5,853
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 43,6101
Latent Gain Btu/hr
Occupants 2.0 Occupants X F Btuh/occ. = 400
Infiltration: 4,771 X 0.87 X 186.82 X 0.00276 = 2,132
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR
0
w
•
R£SWENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
The Madison Club
1 12120/2012
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Living Space
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,414.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
78 OFI
Outdoor Daily Range:
34 OF
.Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X I I
X
=
Page Total
0
Items shown with an asterisk (•) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
14
(W) 0.0 X 15.2 +
15.2
X 30.7
= 466
,/
(VV) 0.0 X 21.2 +
48.0
X 38.4
= 1,842
13
W 13.9 X 15.2 +
3.7
X 30.7
= 325
12
(VV) 11.4 X 15.2 +
3.0
X 30.7
= 266
Y
(NVtq 0.0 X 21.2 +
140.0
X 33.1
= 4,637
27
(NM 0.0 X 15.2 +
9.0
X 26.0
= 234
X +
X
=
X +
X
=
X +1
X
=
Page Total
7,770
Internal Gain
Btu/hr
Occupants
2.0 Occupants X 230
Btuh/occ.
=
460
Equipment
1.0 Dwelling Unit X 1,600
Btu
=
1,600
Infiltration: 1.064
X 0.87 X 186.82 X 34 =
5,853
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
43,610
Latent Gain
Btu/hr
Occupants
2�0 Occupants X 200
Btuh/occ.
_
400
Infiltration: 4,771
X 0.87 X 186.82 X 0.00276 =
2,132
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
2,532
EnerovPro 5.1 bv EneravSoft
User Number: 6712 RunCode: 2012-12-20712:34:44 ID:
Page 30 of 30