11-0611 (SFD) Revision 1 Title 24I BUILDING ENERGY ANALYSIS REPORT I PROJECT: Evertson Residence 53-165 Humboldt Boulevard La Quinta, CA 92253 Project Designer: Andrzej W. Weber Architect 2276 Via Alba Palm Desert, CA 92260 (760) 340-3002 Report Prepared by: Scott DeVoe BREEZE AIR CONDITIONING ti 75-145 St. Charles Place CITY OF � QUINT Palm Desert, CA 92211 A (760) 346-0855 BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA rE 2611 BY %4 - Job Number: FH 5 2011 Date: By 6/29/2011 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29709:40:42 /D: TABLE OF CONTENTS Cover Page* Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 3665 1 2 3 18 21 27 33 39 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Evertson Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 Project Address 53-165 Humboldt Boulevard La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,354 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Rafter Filled 8,354 New Wall Wood Framed Filled 5,701. New Slab Unheated Slab -on -Grade None 8,592 Perim = 547' New Door Opaque Door None 24 New Floor Wood Framed w/o Crawl Space R-38 1,055 New Door Opaque Door None 24 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (N) 15.0 0.370 0.29 none none Bug Screen New Left (E) 15.0 0.370 0.29 none none Bug Screen New Left (E) 15.0 0.370 0.29 none none Bug Screen New Left (E) 42.0 0.370 0.29 5.0 none Bug Screen New Left (E) 42.0 0.370 0.29 5.0 none Bug Screen New Left (E) 4.0 0.350 0.36 none none Bug Screen New Left (E) 4.0 0.350 0.36 none none Bug Screen New Left (E) 4.0 0.350 0.36 none none Bug Screen New Left (E) 15.0 0.370 0.29 none none Bug Screen New Left (E) 44.0 0.570 0.67 none none Bug Screen New Left (E) 4.0 0.350 0.36 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.2 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.2 SEER Setback New 3 Central Furnace 80% AFUE Split Air Conditioner 16.2 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Zone #1 Ducted Ducted Conditioned 6.0 New Zone #2 Ducted Ducted Conditioned 6.0 New Zone #3 Ducted Ducted Conditioned 6.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Large Gas 100 0.80 Kitchen Pipe Ins New Ener Pro 5.1 by Energ Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 3 -of -4-71 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Evertson Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 Project Address 53-165 Humboldt Boulevard La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,354 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status FENESTRATION Orientation Area(ft) U- Exterior Factor SHGC Overhang Sidefins Shades Status Left (E) 4.0 0.350 0.36 none none Bug Screen New Left (E) 4.0 0.350 0.36 none none Bug Screen New Left (E) 60.0 0.370 0.29 6.0 none Bug Screen New Left (E) 9.0 0.370 0.29 none none Bug Screen New Left (E) 9.0 0.370 0.29 none none Bug Screen New Left (E) 12.0 0.370 0.29 • none none Bug Screen New Left (E) 12.0 0.370 0.29 none none Bug Screen New Left (SE) 5.0 0.370 0.29 none none Bug Screen New Left (SE) 42.0 0.370 0.29 8.0 none Bug Screen New Rear (SIM 42.0 0.370 0.29 18.0 none Bug Screen New Rear (SK9. 42.0 0.370 0.29 18.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 20.7 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 20.7 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 20.7 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Zone #4 Ducted Ducted Conditioned 6.0 New Zone #5 Ducted Ducted Conditioned 6.0 New Zone #6 Ducted Ducted Conditioned 6.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 4 of 47 PERFORMANCE CERTIFICATE: Resideritial Part 1 of 5 CF-1 R Project Name Evertson Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 Project Address 53-165 Humboldt Boulevard La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,354 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (N) 54.0 0.350 0.19 22.0 none Bug Screen New Front (N) 17.3 0.370 0.29 none none Bug Screen New Front (N) 24.0 0.350 0.19 18.0 none Bug Screen New Front (N) 12.0 0.350 0.36 none none Bug Screen New Front (N) 4.0 0.350 0.36 none none Bug Screen New Front (N) . 4.0 0.350 0.36 none none Bug Screen New Front (NE) 64.0 0.370 0.29 5.0 none Bug Screen New Front (NE) 10.0 0.350 0.36 none none Bug Screen New Left (SE) 10.5 0.350 0.36 30.0 none Bug Screen New Left (SE) 90.0 0.340 0.32 30.0 none Bug Screen New Rear (S) 210.0 0.340 0.32 30.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Energ Soft User Number. 3665 RunCode: 2011-06-29T09:40:42 ID: Page 5 of 47 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Evertson Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 Project Address 53-165 Humboldt Boulevard La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,354 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special . Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Rear (S) 33.8 0.350 0.36 30.0 none Bug Screen New Rear (S) 4.0 0.350 0.36 none none Bug Screen New Rear (S) 4.0 0.350 0.36 none none Bug Screen New Rear (SM 22.8 0.350 0.36 30.0 none Bug Screen New' Rear (SlM 30.3 0.370 0.29 30.0 none Bug Screen New Rear (SlM 90.0 0.340 0.32 30.0 none Bug Screen New Right (lM 20.0 0.350 0.19 none none Bug Screen New Right (lM 16.0 0.370 0.29 none none Bug Screen New Right (lM 30.0 0.370 0.29 none none Bug Screen New Right (lM 30.0 0.370 0.29 none none Bug Screen New Right (lM 30.0 0.370 0.29 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status M Energ Pro 5.1 by Energ Soft User Number. 3665 RunCode: 2011-06-29709:40:42 ID: Page 6 of 47 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Evertson Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 Project Address 53-165 Humboldt Boulevard La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,354 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (tM 30.0 0.370 0.29 none none Bug Screen New Right (tM 4.0 0.350 0.36 none ' none Bug Screen New Right (l q 4.0 0.350 0.36 none none Bug Screen New Right (149 4.0 0.350 0.36 none none Bug Screen New Right (149 24.0 0.350 0.19 none none Bug Screen New Right (I49 15.0 0.370. 0.29 none' none Bug Screen New Front (NE) 48.0 0.350 0.19 9.0 none Bug Screen New Left (SE) 4.0 0.370 0.29 none none Bug Screen New Left (SE) 6.0 0.370 0.29 none none Bug Screen New Rear (SK9 6.0 0.370 0.29 none none Bug Screen New Right (tq 6.0 0.370 0.29 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID: Page 7 of 47 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Evertson Residence Project Address 53-165 Humboldt Boulevard La Quinta Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 8,354 n/a Date 6/29/2011 # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures --If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features --If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type' Cavit (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (N) 6.0 0.370 0.29 none none Bug Screen New Front (N) 8.0 0.370 0.29 none none Bug Screen New Left (E) 8.0 0.370 0.29 none none Bug Screen New Left (E) 48.0 0.350 0.19 7.0 none Bug Screen New Right (149 4.0 0.370 0.29 none none Bug Screen New Right (W) 4.0 0.370 0.29 none none Bug Screen New Right (lM 4.0 0.370 0.29 none none Bug Screen New Right (W) 8.0 0.370 0.29 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Energ Pro 5.1 by Energ Soft User Number: 3665 RunCode: 2011-06-29T09:40:42 /D: Page 8 of 47 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Evertson Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date I 6/29/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford White 100 Gal is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System Zone #1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. The HVAC System Zone #4 must serve only Sleeping Areas. . The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. The HVAC System Zone #5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. The HVAC System Zone #6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -413 form for each of the measures listed below for final to be given. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System Zone #1 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System Zone #2 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System Zone #3 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System Zone #4 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 9 of 47 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Evertson Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System Zone #5 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts andPlenums. The HVAC System Zone #5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System Zone #6 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #6 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ener Pro 5.1 by Ener Soft User Number 3665 RunCode: 2011-06-29T09:40:42 ID: Pae 10 of 47 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Evertson Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 6/29/2011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 3.70 2.85 0.85 Space Cooling 61.41 57.74 3.68 Fans 12.08 13.43 -1.35 Domestic Hot Water 4.11 2.74 1.37 Pumps 0.00 0.00 0.00 Totals 81.31 76.76 4.55 Percent Better Than Standard: 5.6% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 1,610 266 Fuel Available at Site: Natural Gas (E) 2,264 513 Raised Floor Area: 1,055 (S) 1,591 485 Slab on Grade Area: 8.592 (W) 1,783 233 Average Ceiling Height: 12.0 Roof 8,354 0 Fenestration Average U -Factor: 0.36 TOTAL: 1.497 Average SHGC: 0.30 Fenestration/CFA Ratio: 17.9 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency.Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company BREEZE AIR CONDITIONING 612912011 Address 75-145 St. Charles Place Name Scott Devoe City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone (760) 346-0855 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design; duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Andrzej W. Weber Architect F Address 2276 Via Alba Name Andrzej W. Weber City/State/Zip Palm Desert, CA 92260 Phone (760) 340-3002Signed License # ate Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Pae 11 of 47 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Evertson Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 OPAQUE SURFACE DETAILS Surface Type Area -U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Roof 1,483 0.033 Filled 270 0 New 4.2.2-A23 Zone #1 Wall 313 0.071 Filled 0 90 New - 4.3.1-A15 Zone #1 Wall 530 0.071 Filled 90 90 New 4.3.1-A15 Zone #1 Wall 28 0.071 Filled 180 90 New 4.3.1-A 15 Zone #1 Wall 1881 0.071 Filled 270 90 New 4.3.1-A 15 Zone #1 Slab 1,483 0.730 None 0 180 New 4.4.7-A1 Zone #1 Roof 1,378 0.033 Filled 270 0 New 4.2.2-A23 Zone #2 Wall 64 0.071 Filled 0 90 New 4.3.1-A15 Zone #2 Wall 101 0.071 Filled 45 90 New 4.3.1-A15 Zone #2 Wall 415 0.071 Filled 90 90 New 4.3.1-A15 Zone #2 Wall 139 0.071 Filled 135 90 New 4.3.1-A15 Zone #2 Wall 20 0.071 Filled 180 90 New 4.3.1-A15 Zone #2 Wall 132 0.071 Filled 225 90 New 4.3.1-A15 Zone #2 Slab 1,557 0.730 None 0 180 New 4.4.7-A1 Zone #2 Roof 3,926 0.033 Filled 270 0 New 4.2.2-A23 Zone #3 Wall 413 0.071 Filled 0 90 New 4.3.1-A 15 Zone #3 FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Window 15.0 0.370 NFRC 0.29 NFRC 0 New Wood Clad Lo/E (Oper)(33) Zone #1 2 Window 15.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(32) Zone #1 3 Window 15.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E O er 31 Zone #1 4 Window 42.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(27) Zone #1 5 Window 1 42.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(26) Zone #1 6 Window 4.0 0.350 NFRC 0.36 NFRC 90 New Wood Clad Lo/E (Fix)(28) Abv. Zone #1 7 Window 4.0 0.350 NFRC 0.36 NFRC 90 New Wood Clad Lo/E (Fix)(29) Abv. Zone #1 8 Window 4.0 0.350 NFRC 0.36 NFRC 90 New Wood Clad Lo/E (Fix)(30) Abv. Zone #1 9 Window 15.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(22) Zone #1 10 Window 44.0 0.570 Default 0.67 Default 90 New Default Glass Block (21) Zone #7- 11 Window 4.0 0.350 NFRC 0.36 NFRC 90 New Wood Clad Lo/E (Fix)(23) Abv. Zone #1 12 Window 4.0 0.350 NFRC 0.36 NFRC 90 New Wood Clad Lo/E (Fix)(24) Abv. Zone #1 13 Window 4.0 0.350 NFRC 0.36 NFRC 90 New Wood Clad Lo/E (Fix)(25) Abv. Zone #1 14 Window 60.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(20) Zone #2 15 Window 9.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(19) Zone #2 16 lWindow 9.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(18) Zone #2 (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Ri ht Fin Len H t . LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 7.0 6.0 5.0 1.0 5.0 5.0 5 Bug Screen 0.76 7.0 6.0 5.0 1.0 5.01 5.0 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 6.0 10.0 6.0 1.0 6.0 6.0 15 IBug, Screen i 0.76 16 IBug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID: Pae 12 of 47 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Evertson Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 150 0.071 Filled 45 90 New 4.3.1-A 15 Zone #3 Wall 24 0.071 Filled 90 90 New 4.3.1-A 15 Zone #3 Wall 162 0.071 Filled 135 90 New 4.3.1-A 15 Zone #3 Wall 346 0.071 Filled 180 90 New 4.3.1-A 15 Zone #3 Wall 129 0.071 Filled 225 90 New 4.3.1-A 15 Zone #3 Wall 704 0.071 Filled 270 90 New 4.3.1-A 15 Zone #3 Slab 3,926 0.730 None 0 180 New 4.4.7-A1 Zone #3 Roof 512 0.033 Filled 270 0 New 4.2.2-A23 Zone #4 Wall 66 0.071 Filled 225 90 New 4.3.1-A 15 Zone #4 Wall 193 0.071 Filled 270 90 New 4.3.1-A 15 Zone #4 Wall 83 0.071 Filled 315 90 New 4.3.1-A 15 Zone #4 Slab 1,626 0.730 None 0 180 New 4.4.7-A1 Zone #4 Roof 534 0.033 Filled 270 0 New 4.2.2-A23 Zone #5 Wall 128 0.071 Filled 45 90 New 4.3.1-A15 Zone #5 Wall 229 0.071 Filled 135 90 New 4.3.1-A15 Zone #5 Wall 210 0.071 Filled 225 90 New 4.3.1-A15 Zone #5 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 12.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(17) Zone #2 18 Window 12.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(15) Zone #2 19 Window 5.0 0.370 NFRC 0.29 NFRC 135 New Wood Clad Lo/E O er 16 Zone #2 20 Window 42.0 0.370 NFRC 0.29 NFRC 135 New Wood Clad Lo/E (Oper)(14) Zone #2 21 Window 42.0 0.370 NFRC 0.29 NFRC 225 New Wood Clad Lo/E (Oper)(12) Zone #2 _ 22 Window 42.0 0.370 NFRC 0.29 NFRC 225 New Wood Clad Lo/E (Oper)(13) Zone #2 23 Window 54.0 0.350 NFRC 0.19 NFRC 0 New Wood Clad Fr. Door (0) Zone #3 24 Window 17.3 0.370 NFRC 0.29 NFRC 0 New Wood Clad Lo/E (Oper)(37) Zone #3 25 Window 24.0 0.350 NFRC 0.19 NFRC 0 New Wood Clad Fr. Door (N) Zone #3 26 Window 12.0 0.350 NFRC 0.36 NFRC 0 New Wood Clad Lo/E (Fix)(38) Abv. Zone #3 27 Window 4.0 0.350 NFRC 0.36 NFRC 0 New Wood Clad Lo/E (Fix)(39) Abv. Zone #3 28 lWindow 4.0 0.350 NFRC 0.36 NFRC 0 New Wood Clad Lo/E (Fix)(42) Abv. Zone #3 29 Window 64.0 0.370 NFRC 0.29 NFRC 45 New Wood Clad Lo/E (Oper)(43) Zone #3 30 Window 10.0 0.350 NFRC 0.36 NFRC 45 New Wood Clad Lo/E (Fix)(44) Abv. Zone #3 31 Window 10.5 0.350 NFRC 0.36 NFRC 135 New Wood Clad Lo/E (Fix)(11) Zone #3 32 Window 90.01 0.340 NFRC 0.32 NFRC 135 New Wood Clad Lo/E (SGD)(1) Zone #3 (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Ri ht Fin Len H t I LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 7.0 6.0 8.0 1.0 8.0 8.0 21 Bug Screen 0.76 7.0 6.0 18.01 1.0 18.0 18.0 22 Bug Screen 0.76 7.0 6.0 18.0 1.0 18.0 18.0 23 Bug Screen 0.76 9.0 6.0 22.0 1.0 22.0 22.0 24 Bug Screen 0.76 25 Bug Screen 0.76 8.01 3.0 18.0 1.0 18.0 18.0 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 7.0 6.0 5.0 1.0 5.0 5.0 30 Bug Screen 0.76 31 Bug Screen 0.76 7.0 1.5 30.0 12.0 30.0 30.0 32 JBug Screen 0.76 10.0 9.0 30.0 12.0 30.0 30.0 Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID: Pae 13 of 47 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Evertson Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1612912011 OPAQUE SURFACE DETAILS Surface Type Area Ll- Insulation Factor Cavi Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 44 0.071 Filled 270 90 New 4.3.1-A 15 Zone #5 Wall 35 0.071 Filled 315 90 New 4.3.1-A 15 Zone #5 Door 24 0.500 None 315 90 New 4.5.1-A4 Zone #5 Floor 534 0.029 R-38 0 180 New 4.4.2-A8 Zone #5 Roof 521 0.033 Filled 270 0 New 4.2.2-A23 Zone #6 Wall 175 0.071 Filled 0 90 New 4.3.1-A15 Zone #6. Wall 223 0.071 Filled 90 90 New 4.3.1-A15 Zone #6 Wall 30 0.071 Filled 135 90 New 4.3.1-A 15 Zone #6 Wall 152 0.071 Filled 180 90 New 4.3.1-A 15 Zone #6 Door 24 0.500 None 180 90 New 4.5.1-A4 Zone #6 Wall 282 0.071 Filled 270 90 New 4.3.1-A 15 Zone #6 Floor 521 0.029 R-38 0 180 New 4.4.2-A8 Zone #6 FENESTRATION SURFACE DETAILS ID Type Area Ll -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 210.0 0.340 NFRC 0.32 NFRC 180 New Wood Clad Lo/E (SGD)(J) Zone #3 34 Window 33.8 0.350 1 NFRC 0.36 NFRC 180 New Wood Clad Lo/E (Fix)(10) Zone #3 35 Window 4.0 0.350 NFRC 0.36 NFRC 180 New Wood Clad Lo/E Fix 40 Abv. Zone #3 36 Window 4.0 0.350 NFRC 0.36 NFRC 180 New Wood Clad Lo/E (Fix)(41) Abv. Zone #3 37 Window 22.8 0.350 NFRC 0.36 NFRC 225 New Wood Clad Lo/E (Fix)(9) Zone #3 38 Window 30.3 0.370 NFRC 0.29 NFRC 2251 New Wood Clad Lo/E (Oper)(8) Zone #3 39 Window 90.0 0.340 NFRC 0.32 NFRC 225, New Wood Clad Lo/E (SGD)(H) Zone #3 40 Window 20.0 0.350 1 NFRC 0.19 NFRC 270 1 New Wood Clad Fr. Door (F) Zone #3 41 Window 16.0 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(6) Zone #3 42 Window 30.0 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(34) Zone #3 43 Window 30.0 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(35) Zone #3 44 Window 30.0 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(36) Zone #3 45 Window 30.0 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(2) Zone #4 46 Window 4.0 0.350 NFRC 0.36 NFRC 270 New Wood Clad Lo/E (Fix)(3) Abv. Zone #4 47 Window 4.0 0.350 NFRC 0.36 NFRC 270 New Wood Clad Lo/E (Fix)(4) Abv. Zone #4 48 Window 4.0 0.350 NFRC 0.36 NFRC 270 New Wood Clad Lo/E (Fix)(5) Abv. Zone #4 (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t I Wd Ove hanq Left Fin Ri ht Fin Len H t LExt REA Dist Len H t Dist Len H t 33 Bug Screen 0.76 10.01 21.0 30.0 12.0 30.0 30.0 34 Bug Screen 0.76 7.01 4.8 30.0 12.0 30.0 30.0 35 Bug Screen 0.76 36 Bug Screen 0.76 37 - Bug Screen 0.76 7.0 3.3 30.0 12.0 30.0 30.0 38 Bug Screen 0.76 7.0 4.3 30.0 12.0 30.0 30.0 39 Bug Screen 0.76 10.0 9.0 30.01 12.0 30.01 30.0 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Buq Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 JBug Screen 0.76 48 IBua Screen 0.761 1 Ener Pro 5.1 by Ener Soft User Number: 3665 Runcode: 2011-06-29709:40:42 ID: Pae 14 of 47 CERTIFICATE OF COMPLIANCE: Residential . Part 4 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Evertson Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 1612912011 OPAQUE SURFACE DETAILS Surface U Insulation Joint Appendix Type I Area I Factor I Cavity Exterior I Frame I Interior Frame Azm I Tilt I Status 1 4 1 Location/Comments FEN ID 49 ID 49 156 N SURFACE DETAILS Area U -Factor 24.0 0.350 NFRC 15.0 0.370 NFRC 48.0 0.350 NFRC 4.0 0.370 NFRC 6.0 0.370 NFRC 6.0 0.370 NFRC 6.0 0.370 NFRC 6.0 0.370 NFRC 8.0 0.370 NFRC 8.0 0.370 NFRC 48.0 0.350 NFRC 4.0 0.370 NFRC 4.0 0.370 NFRC 4.01 0.370 NFRC (1) LI -Factor Type: (2) SHGC Type: 116-A = Defau 116-B = Defau 'ERIOR SHADING DETAILS Exterior Shade Type SHGC Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 SHGC` Azm Status 0.19 NFRC 270 New 0.29 NFRC 270 New 0.19 NFRC 45 New 0.29 NFRC 135 New 0.29 NFRC 135 New 0.29 NFRC 2251 New 0.29 NFRC 270 New 0.29 NFRC 0 New 0.29 NFRC 0 New 0.29 NFRC 90 New 0.19 NFRC 90 New 0.29 NFRC 270 New 0.29 NFRC 2701 New 0.29 NFRC 270 New 0.29 NFRC 270 New Table from Standards, NFRC = Labeled Table from Standards, NFRC = Labeled Window Overhana Wood Clad Fr. Door Wood Clad Lo/E (OF Wood Clad Fr. Door Wood Clad Lo/E (OF Wood Clad Lo/E (OF Wood Clad Lo/E (Of Wood Clad Lo/E (Of Wood Clad Lo/E (Of Wood Clad Lo/E (Of Wood Clad WE (Of Wood Clad Fr. Door Wood Clad Lo/E (Of Wood Clad Lo/E (OF Wood Clad WE (04 LEA I RExt 1.01 9.01 9.0 6.01 7.01 1.01 7.01 7 Left Fin Zone #4 Zone #4 Zone #5 Zone #5 Zone #5 Zone #5 Zone #5 Zone #6 Zone #6 Zone #6 Zone #6 Zone #6 Zone #6 Zone #6 Zone #6 ents it Fin nT EnerPro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29T09:40:42 /D: Page 15 of 47 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Evertson Residence Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 113/2.c)/2011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built Zone #1 Mst. Bedroom 1,483 16,313 . Zone #2 Office / Guest Bed 2 & 3 1,378 14,469 Zone #3 Grt. Rm /Kit. /Dining 3,926 54,964 Zone #4 Guest Bed 4 512 5,120 Zone #5 Casita / Guest Bed 5 534 4,806 Zone #6 Casita / Guest Bed 6 521 4,689 Totals 1 8,354 01 01 0 HVAC SYSTEMS System Name Qty. Heatinq Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Zone #1 1 Central Furnace 80% AFUE Split Air Conditioner 16.2 SEER Setback New Zone #2 1 Central Furnace 80% AFUE Split Air Conditioner 16.2 SEER Setback New Zone #3 3 Central Furnace 80% AFUE Split Air Conditioner 16.2 SEER Setback New Zone #4 1 Central Furnace 80% AFUE Split Air Conditioner 20.7 SEER Setback New Zone #5 1 Central Furnace 80% AFUE Split Air Conditioner 70.7 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location. R -Value Ducts Tested? Status Zone #1 Ducted Ducted Conditioned 6.0 m New Zone #2 Ducted Ducted Conditioned 6.0 m New Zone #3 Ducted Ducted Conditioned 6.0 16 New Zone #4 Ducted Ducted Conditioned 6.0 0 INew Zone #5 Ducted Ducted Conditioned 6.01 m INew WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White 100 Gal 2 Large Gas Kitchen Pipe Ins 85,000 100 0.80 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft C 0 ro Q — System Name Pipe Length Pipe Diameter Insul. Thick. Qt . HP Plenum Outside Buried Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Pae 16 of 47 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Evertson Residence Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existinq Altered Removed Volume Year Built Totals 1 8,3541 01 OF 0 HVAC SYSTEMS System Name Qty. Heatin Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Zone #6 1 Central Furnace 80% AFUE Split Air Conditioner 20.7 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Zone #6 Ducted Ducted Conditioned 6.0 m New WATER HEATING SYSTEMS S stem Name aty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft c 0 i� Q — System Name Pipe Length Pipe Diameter Insul. Thick. Qty.THP Plenum Outside Buried Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Pae 17 of 47 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Evertson Residence Date 6/29/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leaka e. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i):The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent LI -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. §150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected.frorn physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise_ residential occupancies meet the air release valve, backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID: Page 18 of 47 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Evertson Residence 6/29/2011 §150(m)1: All air-distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply-air and return-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in'cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m .10: Flexible ducts cannot have porous inner cores. §150(0): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings. Window operation isnot a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro rammed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line- voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw-base socket. §150(k)6: Liqhting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi-scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual-on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoR User Number: 3665 RunCode: 2011-06-29709:40:42 /D: Page 19 of 47 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Evertson Residence 6/29/2011 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less _than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number.- 3665 RunCode: 2011-06-29T09:40:42 ID: Page 20 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Evertson Residence Date 6/29/2011 System Name Zone #1 Floor Area 1,483 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 1,009 18,063 Return Vented Lighting 0 Return Air Ducts 378 Return Fan 0 Ventilation 273 11,570 Supply Fan 0 Supply Air Ducts 378 TOTAL SYSTEM LOAD 1 30,388 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 88,000. 2,444 832 22,002 Total Output (Btuh) 88,000 Output Btuh/s ft 59.3 321 Cooling System 0 Output perSystem 59,500 5,327 273 15,645 Total Output Btuh 59,500 7,771 0 Total Output (Tons) 5.0 321 Total Output (Btuh/s ft) 40.1 Total Output s ft/Ton 299.1 38,289 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Lennox XC21/SL280UHV (5 Ton) 48,189 3,447 88,000 Airflow cfm/s ft 1.35 Airflow cfm/Ton 403.4 Outside Air (%) 13.7% Total Adjusted System Output 48,189. (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 3,447 88,000 Aug 3 PM Jan 1 AM Outside Air (cfm/s ft) 0.18 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 72 OF Outside Air AV - 273 cfm Supply Fan AL 2,000 cfm 80 OF 72 OF 105 OF Heating Coil 105 OF ROOM 80 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 78/63°F 78/64°F 55/54°F Outside Air 273 cfm Ar Supply Fan Cooling Coil 55 / 54 OF 2,000 cfm 52.6% ROOM ,w 72 / 61 OF 72 / 61 OF EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID: Page 21 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Evertson Residence Date 6/29/2011 System Name Zone #2 Floor Area 1,378 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 973 Return Vented Lighting Return Air Ducts Return Fan Ventilation 364 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 88,000 17,433 2,485 775 20,501 Total Output Btuh 88,000 0 Output Btuh/s ft 63:9 365 300 Cooling System 0 0 Output per System 59,500 15,429 7,167 364 20,864 Total Output (Btuh) 59,500 0 365 1 33,591 9,652 0 Total Output ons 5.0 300 Total Output (Btuh/s ft) 43.2 Total Output s ft/Ton 277.9 41,964 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Lennox XC21/SL280UHV (5 Ton) 49,892 2,4251 88,000 Airflow (cfm/s ft) 1.45 Airflow cfm/Ton) 403.4 Outside Air (%) 18.2 % Total Adjusted System Output 49,892 (Adjusted for Peak Design conditions) . TIME OF SYSTEM PEAK 2,425 Aug 3 PM 88,000 I Jan 1 AM Outside Air (cfm/s ft) 0.26 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 364 cfm Supply Fan 2,000 cfm 80 OF 70 OF 105 OF Heating Coil 105 OF Roots in 80 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 79/64°F 79/64°F 55/54°F Outside Air _ 364 cfm Supply Fan Cooling Coil 55 / 54 OF 2,000 cfm - 52.4% ROOM in 72 / 61 OF 72 / 61 OF EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29709:40:42 /D: Page 22 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Evertson Residence Date 6/29/2011 System Name Zone #3 Floor Area 3,926 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 COIL CFM Total Room Loads 2,348 Return Vented Lighting Return Air Ducts Return Fan Ventilation 273 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 88,000 42,142 6,340 2,075 54,936 Total Output (Btuh) 264,000 0 Output Btuh/s ft 67.2 881 803 Cooling System 0 0 Output per System 59,500 11,581 5,262 273 15,652 Total Output (Btuh) 178,500 0 881 .55,485 11,602 0 Total Output (Tons) 14.9 803 Total Output (Btuh/s ft) 45.5 Total Output s ft/Ton 263.9 1 72,193 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 6,000 Lennox XC21/SL280UHV (5 Ton) 134,638 16,104 264,000 Airflow (cfm/s ft) 1.53 Airflow cfm/Ton 403.4 Outside Air (%) 4-6% Total Adjusted System Output 134,638 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 16,104 264,000 Aug 3 PM Jan 1 AM Outside Air (cfm/s ft) 1 0.07 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 26 OF 77 OF Outside Air 273 cfm Supply Fan AL 6,000 cfm 80 OF 77 OF 105 OF Heating Coil 105 OF FROOM 80 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 74162 OF 74 / 62 OF 55 / 54 OF o Outside Air 273 cfm Ar Supply Fan Cooling Coil 55 / 54 OF 6,000 cfm - - 52.9% � ROOM ]" 72/61°F 72/61°F EnergyPro 5.1 by EnergySoff User Number: 3665 RunCode: 2011-06-29T09:40:42 ID: Page 23 of 47 HVAC SYSTEM HEATING. AND COOLING LOADS SUMMARY Project Name Evertson Residence Date 6/29/2011 System Name , Zone #4 Floor Area 512 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 516 9,213 Return Vented Lighting 0 Return Air Ducts 193 Return Fan 0 Ventilation 182 7,704 Supply Fan 0 Supply Air Ducts 193 TOTAL SYSTEM LOAD 1 17,301 COIL HTG. PEAK Latent CFM Sensible 975 445 11,740 172 0 3,626 182 10,420 0 172 4,600 22,503 Heating System Output per System 66,000 Total Output (Btuh) 66,000 Output Btuh/s ft 128.9 Cooling System Output per system 25,600 Total Output (Btuh) 25,600 Total Output (Tons) 2.1 Total Output Btuh/s ft 50.0 Total Output s ft/Ton 240.0 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Lennox XC21/SL280UHV (2 Ton) 22,352 454 66,000 Airflow (cfm/s ft) 1.56 Airflow cfm/Ton 375.0 Outside Air (%) 22.8% Total Adjusted System Output 22,352 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 454 66,000 Aug 3 PM Jan 1 AM Outside Air (cfm/s ft) 0.36 Note: values above givenat ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 °F Outside Air 182 cfm Supply Fan 800 cfm 80 OF 68 OF 105 OF Heating Coil 105 OF Room 80 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 81 /65°F 81 /65°F 55154°F Outside Air 182 cfm AL Supply Fan Cooling Coil55154 800 cfm 52.1 % 72/61 OF 4 *1 1 -.4 —0 1 1 1 -3 .4 OF ROOM 72/61 OF 1 EnergyPro 5.1 by EnergySoft User Number. 3665 RunCode: 2011-06-29709:40:42 /D: Page 24 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Evertson Residence Date 6/29/2011 System Name Zone #5 Floor Area 534 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 357 6,398 Return Vented Lighting 0 Return Air Ducts 134 Return Fan 0 Ventilation 182 7,717 Supply Fan 0 Supply Air Ducts 134 TOTAL SYSTEM LOAD 1 14,383 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 66,000 1,008 326 8,613 Total Output (Btuh) 66,000 Output Btuh/s ft 123.6 126 Cooling System 0 Output. per System 25,600 3,616 182 10,431 Total Output (Btuh) 25,600 4,624 0 Total Output (Tons) 2.1 126 Total Output Btuh/s ft 47.9 Total Output s ft/Ton 250.3 19,295 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Lennox XC21/SL280UHV (2 Ton) 22,315 490 66,000 66,000 Jan 1 AM Airflow (cfm/s ft) 1.50 Airflow cfm/Ton 375.0 Outside Air (%) 22.8% Total Adjusted System Output 22,315 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 490 Aug 3 PM Outside Air (cfm/s ft) 0.34 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 0 Outside Air 182 cfm Supply Fan 800 cfm 80 OF 68 OF 105 OF Heating Coil 105 OF ROOM 80 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 81/65°F 81/65°F 55/54°F Outside Air 182 cfm Ar Supply Fan Cooling Coil 55 / 54 OF 800 cfm 52.2% ROOM 72/61 OF 72/61 OF EnergyPro 5.1 by EnergySoR User Number.- 3665 RunCode: 2011-06-29709:40:42 /D: Page 25 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Evertson Residence 6/29/2011 System Name Floor Area Zone #6 521 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Out ut per System 66,000 Total Room Loads 406 7,260 988 369 9,743 Total Output (Btuh) 66,000 Return Vented Lighting 0 Output Btuh/s ft 126.7 Return Air Ducts 152 .142 Cooling System Return Fan 0 0 Output per System 25,600 Ventilation 182 7,713 3,621 182 10,427 Total Output Btuh 25,600 Supply Fan 0 0 Total Output Tons 2.1 Supply Air Ducts 152 142 Total Output (Btuh/s ft) 49.1 TOTAL SYSTEM LOAD 15,277 4,609 20,455 Total Output s tt/Ton 244.2 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Lennox XC21/SL280UHV (2 Ton) 22,329 475 66,000 Airflow (cfm/s ft) 1.54 Airflow (cfm/Ton) 375.0 Outside Air %) 22-8% Total Adjusted System Output 22,329 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 475 Aug 3PM 66,000 Jan 1 AM Outside Air (cfm/s ft) 0.35 Note: values above given at.ARl conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 68 OF 105 OF Outside Air 182 cfm Supply Fan Heating Coil 105 OF 800 cfm ROOM 80 OF 80 °F COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 81!65°F 81/65°F 55/54°F 0 � Outside Air 182 cfm Supply Fan Cooling Coil 55 / 54 OF 800 cfm 52.1 % .- ROOM EQ] 72161 OF 1-4 72/61 OF EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29709:40:42 /D: Page 26 of 47 ROOM LOAD SUMMARY Project Name Date Evertson Residence 6/29/2011 System Name Floor Area Zone #1 1,483 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name I Mult. I CFM I Sensible Latent CFM I Sensible I Latent CFM Sensible Zone #1 Mst. Bedroom 1 1,009 18,063 2,444 1,009 18,063 2,444 832 22,002 PAGE TOTAL TOTAL• 1,009 18,0631 2,4441 832 22, 002 1,009 18,0631 2,4441 832 22,002 Total includes ventilation load for zonal systems. Ener Pro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 27 of 47 ROOM LOAD SUMMARY Project Name Date Evertson Residence 6/29/2011 System. Name Floor Area Zone #2 1,378 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM I Sensible Zone #2 Office / Guest Bed 2 & 3 1 1 973 17,433 2,485 973 17,433 2,485 7751 20,501 PAGE TOTAL TOTAL* * Total includes ventilation load for zonal 973 17,433 2,485 775 20,501 973 17,433 2,485 775 20,501 Ener Pro 5.1 by EnerqySoft User Number: 3665 RunCode: 2011-06-29709:40:42 - ID: Page 28 of 47 ROOM LOAD SUMMARY Project Name Date Evertson Residence 6/29/2011 System Name Floor Area Zone #3 3,926 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone #3 • Grt. Rm / Kit. / Dining 1 2,3481 42,142 6,340 2,3481 42,142 6, 340 . 2,0751 54,936 PAGE TOTAL TOTAL' 2,348 42,142 6,3401 Z0751 54,936 2,348 42,142 6,3401 2,0751 54,93 Total includes ventilation load for zonal systems. Ener Pro 5.1 by EnerqySoft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 29 of 47 ROOM LOAD -SUMMARY - Evertson Residence 6/29/2011 System Name Floor Area Zone #4 512 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible Latent CFM I Sensible Latent I CFM I Sensible Zone #4 Guest Bed 4 1 516 9,213 975 516 9,2131 9751 4451 11,740 PAGE TOTAL TOTAL* * Total includes ventilation load for zonal 516 9,213 975 445 11,740 516 9,213 975 445 11,740 of 47 ROOM LOAD SUMMARY Project Name Date Evertson Residence 6/29/2011 System Name Floor Area Zone #5 534 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible Latent CFM I Sensible I Latent I . CFM Sensible Zone #5 Casita /Guest Bed 5 1 1 357 6,3981 1,008 3571 6,3981 1,008 326 8,613 PAGE TOTAL TOTAL• 57 P357 6,3981 1,0081 326 8,613 6,398 1,008 326 8,613 ' Total includes ventilation load for zonal systems. Ener Pro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 31 of 47 ROOM LOAD SUMMARY Project Name Date Evertson Residence 6/29/2011 System Name Floor Area Zone #6 521 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM Sensible I Latent CFM I Sensible Latent CFM I Sensible Zone #6 Casita / Guest Bed 6 1 1 406 7,2601 988 406 7,2601 988 369 9,743 PAGE TOTAL TOTAL' Total includes ventilation 406 7,260 988 369 9,743 406 7,260 988 369 9,743 ROOM HEATING PEAK LOADS Project Name Evertson Residence ' - Date 7 6/29/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Mst. Bedroom Floor Area 1,483.0 ft2 Indoor Dry Bulb Temperature 80 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value AT °F = = = = = - = = = = = = = = = = = = = = = = = = = = = = = = = 54 Btu/hr Icynene (Roof). (R-38, 10" Thk) 1,483.0 X 0.0330 X 54 2,643 Icynene (Wall) (R-21, 5.5"Thk) 1,058.0 X X X 0.0710 X X X 54 4,056 Wood Clad Lo/E (Oper)(33) 15.0 0.3700 54 300 Wood Clad Lo/E (Oper)(32) 15.0 0.3700 54 300 Wood Clad WE (Oper)(31) 15.0 X X 0.3700 X X 54 300 Wood Clad WE (Oper)(27) 42.0 0.3700 54 839 Wood Clad WE (Oper)(26) 42.0 X 0.3700X 54 839 Wood Clad WE (Fix)(28) Abv. 4.0 X X X 0.3500 X X X 54 76 Wood Clad Lo/E (Fix)(29) Abv. 4.0 0.3500 54 76 Wood Clad Lo/E (Fix)(30) Abv. 4.0 0.3500 54 76 Wood Clad WE (Oper)(22) 15.0 X 0.3700 X 54 300 Default Glass Block (21) 44.0 X X 0.5700 X X 54 1,354 Wood Clad Ld/E (Fix)(23) Abv. 4.0 0.3500 54 76 Wood Clad WE (Fix)(24) Abv. 4.0 X X X 0.3500 X X X 54 76 Wood Clad WE (Fix)(25) Abv. 4.0 0.3500 54 76 Slab -On -Grade perim = 103.0 0.7300 54 4,060 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:l 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,483 X Area to another room 11.00 X 0.420 Ceiling Height ACH Page Total /60] X AT 15,444 = 6,557 TOTAL HOURLY HEAT LOSS FOR ROOM 22,002 EnergyPro 5.1 by EnergySoft User Number. 3665 RunCode: 2011-06-29T09:40:42 ID: Page 33 of 47 ROOM HEATING PEAK LOADS Project Name Evertson Residence Date 6/29/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Office / Guest Bed 2 & 3 Floor Area 1,378.0 ft2 Indoor Dry Bulb Temperature 80 OF Time of Peak Outdoor Dry Bulb Temperature Jan 1 AM 26 OF Conduction Area Icynene (Roof) (R-38, 10" Thk) 1,378.0 X Icynene (Wall) (R-21, 5.5" Thk) 870.0 X Wood Clad Lo/E (Oper)(20) 60.0 X Wood Clad Lo/E (Oper)(19) 9.0 X Wood Clad Lo/E (Oper)(18) 9.0 X Wood Clad Lo/E (Oper)(17) 12.0 X Wood Clad WE (Oper) (15) 12.0 X Wood Clad Lo/E (Oper)(16) 5.0 X Wood Clad Lo/E (Oper)(14) 42.0 X Wood Clad Lo/E (Oper)(12) 42.0 X Wood Clad Lo/E (Oper)(13) 42.0 X Slab-On-Grade perim = 100.5 X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (`) denote conduction through an interior surface to Infiltration:[ 1.00 X 1.064 X 1,378 X Schedule Air Sensible Area Ceiling Fraction U-Value 0.0330 X 0.0710 X 0.3700 X 0.3700 X 0.3700 X 0.3700 X 0.3700 X 0.3700 X 0.3700 X 0.3700 X 0.3700 X 0.7300 X X X X X X X X X X X X X X X X X X x X another room 10.50 X 0.440 Height ACH AT °F 54 = 54 = 54 = 54 = 54 = 54 = 54 = 54 = 54 = 54 = 54 = 54 = _ = = = = = = = = = = = = = = = = = = Page Total /60] X 54 AT Btu/hr 2,456 3,336 1,199 180 180 240 240 100 839 839 839 3,962 14,408 = 6,093 TOTAL HOURLY HEAT LOSS FOR ROOM 20,501 EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 34 of 47 ROOM HEATING PEAK LOADS Project Name Evertson Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Grt. Rm /Kit. /Dining Time of Peak Floor Area 3,926.0 ft' Outdoor Dry Bulb Temperature Indoor Dry Bulb Temperature 80 OF Conduction Area H-Vahio Icynene (Roof) (R-38, 10" Thk) Icynene (Wall) (R-21, 5.5".Thk) Wood Clad Fr. Door (0) Wood Clad Lo/E (Oper)(37) Wood Clad Fr. Door (N) Wood Clad Lo/E (Fix)(38) Abv. Wood Clad Lo/E (Fix)(39) Abv. Wood Clad Lo/E (Fix)(42) Abv. Wood Clad Lo/E (Oper)(43) Wood Clad Lo/E (Fix)(44) Abv. Wood Clad Lo/E (Fix)(11) Wood Clad Lo/E (SGD)(1) Wood Clad Lo/E (SGD)(J) Wood Clad Lo/E (Fix)(10) ` Wood Clad Lo/E (Fix)(40) Abv. Wood Clad Lo/E (Fix)(41) Abv. Wood Clad Lo/E (Fix)(9) Wood Clad Lo/E (Oper)(8) Wood Clad WE (SGD)(H) Wood Clad Fr. Door (F) Wood Clad Lo/E (Oper)(6) Wood Clad WE (Oper)(34) Wood Clad Lo/E (Oper)(35) Wood Clad Lo/E (Oper)(36) Slab -On -Grade 3,926.0 1,927.3 54.0 17.3 24.0 12.0 4.0 4.0 64.0 10.0 10.5 90.0 210.0 33.8 4.0 4.0 22.8 30.3 90.0 20.0 16.0 30.0 30.0 30.0 perim = 199.0 X .0.0330 X 0.0710 X 0.3500 X X X X 0.3700 0.3500 0.3500 0.3500 X 0.3500 X 0.3700 X 0.3500 X 0.3500 X 0.3400 X X X X 0.3400 0.3500 0.3500 0.3500 X 0.3500 X 0.3700 X 0.3400 X 0.3500 X X X 0.3700 0.3700 0.3700 X 0.3700 X 0.7300 X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to another room Infiltration:[ 1.00 x 1.084 X 3,926 X 14.00 X 0.330 Schedule Air Sensible Area Ceiling Height ACH AT °F' 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 Page Tc /60] XC AT 6/29/2011 Jan 1 AM 26 OF Btu/hr . 6, 996 7,369 1,021 346 454 c 227 c 76 76 c 1,279 c 189 198 1,652 c 3,856 639 76 76 431 605 1,652 c 378 c 320 599 599 599 7,845 tal 37,577 54 = 17,359 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 54,936 Energ Pro 5.1 by Energ Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 35 of 47 ROOM HEATING PEAK LOADS Project Name Evertson Residence Date 6/29/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Bed 4 Floor Area 512.Oft' Indoor Dry Bulb Temperature 80 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 512.0 X 341.0 X U -Value 0.0330 X 0.0710 X 0.3700 X 0.3500 X AT °F 54 c 54 = 54 = 54 = 54 = 54 = 54 = 54 = 54 = = = _ = = = = = = = = = = = = = = = = = Page Total / 60 � X 54 AT Btu/hr Icynene (RooO (R-38, 10" Thk) 912 Icynene (Wall) (R-21, 5.5" Thk) 1,307 Wood Clad Lo/E (Oper)(2) 30.0 X X X X X 599 Wood Clad WE (Fix)(3) Abv. 4.0 76 Wood Clad WE (Fix)(4) Abv. 4.0 0.3500 X X 76 Wood Clad Lo/E (Fix)(5) Abv. 4.0 0.3500 76 Wood Clad Fr. Door (E) 24.0 0.3500 X X X X X X 454 Wood Clad Lo/E (Oper)(1) 15.0 X 0.3700 300 Slab -On -Grade perim = 144.0 X X 0.7300 5,676 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (`) denote conduction Infiltration:[ 1.00 )( 1.064 Schedule Air Sensible Fraction through an interior surface to X 512 X Area Ceiling another room 10.00 X 0.462 Height ACH 9,476 = 2,264 TOTAL HOURLY HEAT LOSS FOR ROOM 11,740 Energ Pro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 36 of 47 ROOM HEATING PEAK LOADS Project Name Evertson Residence Date 6/29/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita / Guest Bed 5 Floor Area 534.0 ft2 Indoor Dry Bulb Temperature 80 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature_ 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = = = = = = = = = = = = = = = = = - = = = = = = = = = 54 Btu/hr Icynene (Root) (R-38, 10" Thk) 534.0 0.0330 54 952 Icynene (Wall) (R-21, 5.5"Thk) 644.0 0.0710 54 2,469 Wood Clad Fr. Door (lM 48.0 0.3500 54 907 Wood Clad Lo/E (Oper)(55) 4.0 0.3700 54 80 Wood Clad Lo/E (Oper)(54) 6.0 0.3700 54 120 Wood Clad Lo/E (Oper)(53) 6.0 0.3700 54 120 Wood Clad Lo/E (Oper)(52) 6.0 0.3700 54 120 Wood Door (V) 24.0 0.5000 54 648 Icynene (Floor) (R-38, 10" Thk) 534.0 0.0290 54 836 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 534 X Area another room 9.00 X 0.513 Height ACH Page Total /60] X AT 6,252 = 2,361 TOTAL HOURLY HEAT LOSS FOR ROOM 8,613 EnergyPro 5.1 by EnergySoft User Number.- 3665 Runcode: 2011-06-29709:40:42 ID: Page 37 of 47 ROOM HEATING PEAK LOADS Project Name7.612912011 Evertson Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Casita / Guest Bed 6 Floor Area 521.0 ft2 Indoor Dry Bulb Temperature 80 OF. Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value 0.0330 X 0.0710 X 0.3700 X 0.3700 X 0.3700 X 0.3500 X 0.5000 X 0.3700 X 0.3700 X 0.3700 X 0.3700 X 0.0290 X X X X X X X X X X X X X X X X X X X X another room 9.00 X 0.513 Height ACH AT °F 54 = Btu/hr Icynene (Roof) (R-38, 10" Thk) 521.0 928 Icynene (Wall) (R-21, 5.5" Thk) 861.0 54 = 3,301 Wood Clad Lo/E (Oper)(47) 6.0 54 = 120 Wood Clad Lo/E (Oper)(46) 8.0 54 = 160 Wood Clad Lo/E (Oper)(56) 8.0 54 = 160 Wood Clad Fr. Door (T) 48.0 54 = = 907 Wood Door (S) 24.0 54 648 Wood Clad Lo/E (Oper)(51) 4.0 54 = = 80 Wood Clad Lo/E (Oper)(50) 4.0 54 80 Wood Clad Lo/E (Oper)(49) 4.0 54 = 80 Wood Clad Lo/E (Oper)(48) 8.0 54 = 160 Icynene (Floor) (R-38, 10" Thk) 521.0 54 = 816 = Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 521 X Area Page Total /60] X 54 AT 7,440 = 2,304 TOTAL HOURLY HEAT LOSS FOR ROOM 9,743 Energ Pro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 38 of 47 I RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Evertson Residence 6/29/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Mst. Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,483.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF Outdoor Daily Range: 34 OF. Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr Icynene (Root) (R-38, 10" Thk) (W) 1,483.0 X 0.0330 X 56.0 = 2,741 Icynene (Wall) (R-21, 5.5" Thk) - (N) 313.0 X 0.0710 X 23.0 = 511 Icynene (Wall) (R-21, 5.5" Thk) (E) 530.0 X 0.0710 X 33.0 = 1,242 Icynene (Wall) (R-21, 5.5" Thk) (S) 27.5 X 0.0710X 26.0 = 51 Icynene (Wall) (R-21, 5.5" Thk) 167.5 X 0.0710 X 33.0 = 439 15.0 X - X X = X X = X X = X J X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fenestration OperWdw (5030)(33) OperWdw (5030)(32) OperWdw (5030)(31) OperWdw (6070)(27) OperWdw (6070)(26) FxWdw (2020) Abv.(28) FxWdw (2020) Abv. (29) FxWdw (2020) Abv.(30) OperWdw (5030)(22) Orientation (N) (E) (E) (E) (E) (E) (E) (E) (E) 1 4,9841 Shaded Area GLF 18.2 + 18.2 + 18.2 + 18.2 + 18.2 + 20.4 + 20.4 + 20.4 + 18.2 + Unshaded Area 15.0 X 15.0 X GLF 18.2 = 0.0 X X 0.0 35.4 = 0.0 X 15.0 X X X 35.4 = = = 18.0 X X 24.0 35.4 18.0 24.0 35.4 0.0 X 0.0 X 0.0 X 0.0 X 4.0 X X X 41.7 = = 4.0 41.7 4.0 41.7 = 15.0 X Page Total Btu/hr 272 531 531 1,176 1,176 167 167 167 531 4,7171 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. _ 230 Equipment 0.0 Dwelling Unit X 1,600 Btu - 0 Infiltration: 1.064 X 1.24 X 81.15 X 40 = 4,285 Air Sensible . CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,063 Latent Gain Btu/hr Occupants 1.0 Occupants X 200Btuh/occ. = 200 Infiltration: 4,771 X 1.24 X 81.15 X 0.00467 = 2 P44 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2.444 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Evertson Residence 6/29/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Mst. Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,483.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF Outdoor Daily Range: 34 OF Opaque Surfaces ` Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X - X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr ' GIsBIk (8056)(21) (E) 0.0 X 36.3 + 44.0 X 76.0 = 3,346 FxWdw (2020) Abv.(23) (E) 0.0 X 20.4 + 4.0 X 41.7 = 167 FxWdw (2020) Abv.(24) (E) 0.0 X 20.4 + 4.0 X 41.7 = 167 FxWdw (2020) Abv.(25) (E) 0.0 X 20.4 + 4.0 X 41.7 = 167 X + X - X + X - X + X - X + IX - X + X - Page Total 3,847 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 )( 1.24 X 81.15 X 40 = 4,285 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,063 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 1.24 X 81.15 X 0.00467 = 2,244 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,444 Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 40 of 47 RESIDENTIAL ROWCOOLING LOAD SUMMARY Project -Name Date Evertson Residence 76/29/2011 ROOM INFORMATION DESIGN CONDITIONS . Room Name Office /.Guest Bed 2 & 3 Outdoor Dry Bulb Temperature 112 °F Floor Area 1,378.0 ft? Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature - 72 OF Outdoor Daily Range: 34 OF Opaque Surfaces Icynene (Roof) (R-38, 10" Thk) Icynene (Wall) (R-21, 5.5" Thk) Icynene (Wall) (R-21, 5.5" Thk) Icynene (Wall) (R-21, 5.5" Thk) Icynene (Wall) (R-21, 5.5" Thk) Icynene (Wall) (R-21, 5.5" Thk) Icynene (Wall) (R-21, 5.5" Thk) Orientation (S) Area X X X X X X X X X U -Factor X X X X X X X X X. CLTD' = = = = = = = = _ 1,378.0 0.0330 77.0 64.0 0.0710 31.0 100.5 0.0710 34.0 415.0 0.0710 44.0 139.0 0.0710 43.0 19.5 0.0710 38.0 132.0 0.0710 52.0 J Page Total IItems shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fenestration OperWdw (10060)(20) OperWdw (3030)(19) OperWdw (3030)(18) OperWdw (4030)(17) OperWdw (4030)(15) OperWdw (2620)(16) OperWdw (6070)(14) OperWdw (6070)(12) OperWdw (6070)(13) Orientation (E) (E) (E) (E) (E) (SE) (SE) (Std (SW) Btu/hr 3,501 141 243 1,296 424 53 1 6,1461 Shaded Area GLF 38.0 X 21.7 0.0 X 21.7 0.0 X 21.7 0.0 X 21.7 0.0 X 21.7 0.0 X 21.7 42.0 X 21.7 42.0 X 21.7 42.0 X 21J Unshaded Area + 22.0 + 9.0 X X X X X X X X X GLF = = = = = = = = 47.6 47.6 + + 9.0 47.6 12.0 47.6 + 12.0 47.6 + + + 5.0 46.9 0.0 46.9 0.0 59.1 +1 0.0 Page Total Btu/hr 1,873 428 428 571 571 234 913 913 913 Internal Gain Btu/hr Occupants 2.0 OccupantsX 230 Btuh/occ. _ 460 Equipment 0.0 Dwelling Unit X 1,200 Btu - 0 Infiltration: 1.064 X 1.24 X 75.40 X 40 = 3,982 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,433 Latent Gain Btu/hr Occupants 2.0 Occupants X 200 Btuh/occ. = 400 Infiltration: 4,771 X 1.24 X 75.40 X 0.00467 = 2,085 Air Sensible CFM ELA AW [TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 9 dpF RESIDENTIAL ROOM COOLING LOAD SUMMARY rrulecr rvarue Date Evertson Residence 6/29/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Grt. Rm / Kit. / Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 3,926.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF Outdoor Daily Ranqe: 34 OF Surfaces Icynene (Roof) (R-38, 10" Thk) Icynene (Wall) (R-21, 5.5" -Thk) Icynene (Wall) (R-21, 5.5" Thk) Icynene (Wall) (R-21, 5.5" Thk) Icynene (Wall) (R-21, 5.5" Thk) Icynene (Wall) (R-21, 5.5" Thk) Icynene (Wall) (R-21, 5.5" Thk) Icynene (Wall) (R-21, 5.5" Thk) I (NE) I I'm I Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = c = c c = = 3,926.0 0.0330 56.0 413.2 0.0710 23.0 150.0 0.0710 29.0 24.0 0.0710 33.0 161.5 0.0710 31.0 346.2 0.0710 26.0 128.9 0.0710 31.0 703.5 0.0710 33.0 X X X 20.4 = 18.2 64.0 Paqe Total IItems shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) FPflAC}fA}1[1rfl SwngGIsDr (6090)(0) FxdWdw (2866)(37) SwngGIsDr (3080)(N) FxWdw (2060) Abv.(38) FxWdw (2020) Abv.(39) FxWdw (2020) Abv.(42) OperWdw (8080)(43) FxWdw (5020) Abv. (44) FxdWdw (1670)(11) Orientation (N) Btu/hr 7,255 675 309 56 355 639 284 1, 648 1 11,2221 Shaded Area GLF Unshaded Area + 54.0 X + 17.3 X + 24.0 X + 12.0 X + 4.0 X GLF 0.0 X X 14.1 14.1 = 0.0 18.2 18.2 = 0.0 X X X 14.1 14.1 c 0.0 20.4 20.4 c 0.0 20.4 20.4 = 0.0 X 0.0 X 0.0 X 10.5 X 20.4 + + + 4.0 X X X 20.4 = 18.2 64.0 27.5 = 20.4 10.0 Latent Gain 20.4 +1 0.01 X 2.0 Occupants X 200 Btuh/occ. = 400 Page Total Btu/hr 759 314 337 244 81 81 1,759 319 214 4,110 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. 460 Equipment 1.0 Dwelling Unit X 1,600 Btu - _ 1,600 Infiltration: )( 1.24 X 214.83 X 40 '= 11,345 Sensible Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 42,142 Latent Gain Btu/hr Occupants 2.0 Occupants X 200 Btuh/occ. = 400 Infiltration: X 1.24 X 214.83 X 0.00467 = 5,940 Sensible Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM a '2An RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Evertson Residence 6/29/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Grt. Rrri / Kit. / Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 3,926.0 ft2 Outdoor Wet Bulb Temperature 78 °F Indoor Dry Bulb Temperature 72 OF Outdoor Dailv Ranae: 34 OF ue Surfaces Orientation Area U -Factor CLTD' X X = X X = X X = X X = X X = X X = X X = X X X X Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration S/dgG/sDr (90100)(/) S/dgG/sDr (210100)(J) FxdWdw (41070)(10) FxWdw (2020) Abv.(40) . FxWdw (2020) Abv.(41) FxdWdw (3370)(9) OperWdw (4470)(8) S/dgG/sDr (90100)(H) SwngG/sDr (2680)(F) Orientation (SE) (S) (S) (S) (S) (SK9 (S K9 (SIAL (� Shaded Area GLF + + + + + + + + + Unshaded Area 0.0 X 0.0 X GLF = = = = 0 0 = = = 90.0 X X 18.7 26.0 210.0 •18.7 18.7 33.8 X 20.4 0.0 X X X X X 20.4 0.0 X 20.4 4.0 20.4 0,01 X 20.4 4.0 20.4 22.8 X X 20.4 0.0 28.6 30.3 18.2 0.0 24.8 90.0 X 0.0 X 18.7 0.0 X 20.0 X 26.0 14.1 25.3 Page Total Btu/hr 01 Btu/hr 1,681 3,922 688 82 82 464 550 1.681 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460 Equipment 1.0 Dwelling Unit X 1,600 Btu c 1,600 Infiltration: 1.064 )( 1.24' X 214.83 X 40 = 11,345 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM NBtu/h Latent Gain Occupants 2•o Occupants X 20o Btuh/occ.Infiltration: sibleX X X Air Sensible CFM ELA ptp/ I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM a awn RESIDENTIAL ROOM COOLING LOAD SUMMARY' Project Name Date Evertson Residence 6/29/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Grt. Rm /Kit. /Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 3,926.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X _ -X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr OperWdw (4040)(6) (W) 0.0 X 18.2 + '16:0 X 35.4 = 566 OperWdw (6050)(34) (W) 0.0 X 18.2 + 30.0 X 35.4 c 1,061 OperWdw (6050)(35) (W) 0.0 X 18.2 + 30.0 X 35.4 = 1,061 OperWdw (6050)(36) (W) 0.0 X 18.2 + 30.0 X 35.4 = 1,061 X + X - X + X - X + X - X + X - X + X - Page Total 3,750 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. 460 Equipment 1.0 Dwelling Unit X 1,600 Btu _ 1,600 Infiltration: 1.064 X 1.24 X 214.83 X 40 = 11,345 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 42,142 Latent Gain Btu/hr Occupants 2.0 Occupants X 200 Btuh/occ. = 400 Infiltration: X 1.24 X 214.83 X 0.00467 = 5,940 Sensible Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,340 Ener Pro 5.1 by Ene Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 44 of 47 RESIDENTIAL ROOM COOLING LOAD. SUMMARY Project Name Date Evertson .Residence 6/29/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Bed 4 Outdoor Dry Bulb Temperature 112 OF Floor Area 512.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72.°F I Outdoor Daily' Range: 34 OF Opaque Surfaces Orientation Area U -Factor - CLTD' Btu/hr. . Icynene (Roof) (R-38, 10" Thk) 512.0 X 0.0330 X 77.0 = 1,301 Icynene (Wall) (R-21, 5.5" Thk) (StM 66.0 X 0.0710 X 52.0 = 244 Icynene (Wall) (R-21, 5.5" Thk) (149 192.5 X 0.0710 X 55.0 = 752 Icynene (Wall) (R-21, 5.5" Thk) (NtA9 82.5 X 0.0710 X - 48.1 = 282 X X' _ X X = X X = X X = X X = Page Total 2,578 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr OperWdw (6050)(2) (K9 0.0 X 21.7 + 30.0 X 64.8 = 1,944 FxWdw (2020) Abv. (3) W 0.0 X 24.8 + 4.0 X 78.2 = 313 FxWdw (2020) Abv. (4) (W) .0.0 X 24.8 + 4.0 X 78.2 = 313 FxWdw (2020) Abv.(5) (tM 0.0 X 24.8 + 4.0 X 78.2 = 313 SwngGIsDr(3080)(E) (W) 0.0 X 16.4 + 24.0 X 44.6 = 1,070 OperWdw (5030)(1) 0.0 X 21.7 + 15.0 X 64.8 = 972 X + X - X + X - X +1 X - Page Total 4,925 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,200 Btu = 0 Infiltration: 1.064 X 1.24 X 28.02 X 40 = 1,479 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,213 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 1.24 X 28.02 X 0.00467 = 775 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 975 Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 45 of 47 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Evertson Residence 6/29/2011. ROOM INFORMATION DESIGN CONDITIONS Room. Name Casita / Guest Bed 5 Outdoor Dry Bulb Temperature 112 OF Floor Area 534.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF Outdoor Daily Range: 34 OF, Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr Icynene (Roof) (R-38, 10" Thk) (149 534.0 X 0.0330 X 56.0 - = 987 Icynene (Wall) (R-21, 5.5" Thk) (NE) 127.5 X 0.0710 X 29.0 = 263 Icynene (Wall) (R-21, 5.5" Thk) (SE) 228.5 X 0.0710 X 31.0 = 503 Icynene (Wall) (R-21, 5.5" Thk) (St9 210.0 X 0.0710 X 31.0 = 462 Icynene (Wall) (R-21, 5.5" Thk) (149 43.5 X 0.0710 X 33.0 = 102 Icynene (Wall) (R-21, 5.5" Thk) (NlM 34.5 •X 0.0710 X 30.2 c 74 Wood Door (Vq (NKq 24.0 X 0.5000 X 30.2 = 363 Icynene (Floor) (R-38, 10" Thk) 534.0 X 0.6290 X 19.0 c 294 X X = Items shown with an•asterisk (') denote conduction through an interior surface to another room. Page Total 3,047 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF . Btu/hr SwngGlsDr (6080)(149 (NE) 0.0 X 14.1 + 48.0 X 20.2 c 968 OperWdw (2020)(55) (SE) 0.0 X 18.2 + 4.0 X 24.8 = 99 OperWdw (3020)(54) (SE) 0.0 X 18.2 + 6.0 X 24.8 c 149 OperWdw (3020)(53) (SK9 0.0 X 18.2 + 6.0 X 24.8 c 149 OperWdw (3020)(52) W 0.0 X 18.2 + 6.0 X 35.4 c 212 X + X _ X + X - X + X _ X + X - Page Total 1,577 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.24 X 29.22 X 40 = 1,543 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,398 Latent Gain Occupants 1.0 Occupants X 200 Btuh/occ. Btu/hr = 200 Infiltration: 4,771 X 1.24 X 29.22 X 0.00467 = 808 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,008 Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID: Page 46 of 47 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Evertson Residence 6/29/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita 7 Guest Bed '6 Outdoor Dry Bulb Temperature 112 OF Floor Area 521.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr Icynene (Root) (R-38, 10" Thk) (149 521.0 X 0.0330 X, 56.0 = 963 Icynene (Wall) (R-21, 5.5" Thk) (N) 175.0 X 0.0710 X 23.0 = 286 Icynene (Wall) (R-21, 5.5" Thk) (E) 223.0 X 0.0710 X 33.0 = 522 Icynene (Wall) (R-21,•5.5" Thk) (SE) 30.0 X 0.0710 X 31.0 = 66 Icynene (Wall) (R41, 5.5" Thk) (S) 151.5 X 0.0710 X 26.01 280 .Wood Door (S) (S) 24.0 X 0.511 000 X 26.0 = 312 Icynene (Wall) (R-21, 5.5" Thk) (VV) 281.5 X 0.0710 X 33.0 = 660 Icynene (Floor) (R-38, 10" Thk) 521.0 X 0.0290 X 19.0 = 287 X J X = Page Total 3,375 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr OperWdw (3020)(47) (N) 0.0 X 18.2 + 6.0 X 18.2 = 109 OperWdw (4020)(46) (N) 0.0 X 98.2 + - 8.0 X 18.2 = 145 OperWdw (4020)(56) (E) 0.0 X 18.2 + 8.0 X 35.4 = 283 SwngG/sDr (6080)(7) (E) 27.6 X 14.1+ 20.4 X 25.3 = 905 OperWdw (2020)(51) (►M 0.0 X 18.2 + 4.0 X 35.4 = 142 OperWdw (2020)(50) (169 0.0 X 18.2 + 4.0 X 35.4 = 142 OperWdw (2020)(49) 0.0 X 18.2 + 4.0 X 35.4 = 142 OperWdw (4020)(48) 0.0 X 18.2 + 8.0 X 35.4 = 283 X 1 +1 X = Page Total 2,149 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.24 X 28.51 X 40 = 1,505 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7,260 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 1.24 X 28.51 X 0.00467 = 788 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 988 Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 47 of 47 r Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011 1 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Evertson Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 Project Address 53-165 Humboldt Boulevard La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,354 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Roof Wood Framed Rafter Filled 8,354 New Wall Wood Framed Filled 5,701 New Slab Unheated Slab -on -Grade None 8,592 Perim = 547' New Door Opaque Door None 24 New Floor Wood Framed w/o Crawl Space R-38 1,055 New Door Opaque Door None 24 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC , Overhang Sidefins Shades Status Front (N) 15.0 0.370 _ 0.29 none none Bug Screen New Left (E) 15.0 0,370 e _ Bug Screen New Left (E) 15.0 0 370 C 0. no Bug Screen New Left (E) 42.0 0. 70RJ III DING ne Bug Screen � New Left (E) 42.0 0. 70 fun an OV P De Bug Screen New Left (E) 4.0 0. 50 flh none Screen New tJe:FBug Left(E) 4.0 0. 50 F 6CQ none Bug. Screen New Left (E) 4.0 0. Bug Screen New Left (E) 15.0 0.3 Left (E) 44.0 0.5 &040,364one BY Bug Screen New none Bug Screen New Left (E) 4.0 0.350 0.36 none none Bug Screen New HVAC SYSTEMS Ot . HeatingMin. Eff t_ (pit Cooling"Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.2 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.2 SEER Setback New 3 Central Furnace 80% AFUE Split Air Conditioner 16.2 SEER Setback New HVAC DISTRIBUTION Location Heating to Duct Cooling _Duct Location R -Value Status Zone #1 Ducted Ducted Conditioned 6.0 New Zone #2 Ducted Ducted Conditioned 6.0 New Zone #3 Ducted Ducted Conditioned 6.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 2 Large Gas 100 0.80 Kitchen Pipe Ins New Energ Pro 5.1 by Ener Soft User Number: 3665 Run Code: 2011-06-29T09:40:42 ID: Pae 1 of 15 Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Evertson Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 Project Address 53-165 Humboldt Boulevard La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,354 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status FENESTRATION Orientation Area(fe) U- Exterior Factor SHGC Overhang Sidefins Shades Status Left (E) 4.0 0.350 0.36 none none Bug Screen New Left (E) 4.0 0.350 0.36. none - none Bug Screen New Left (E) 60.0 0.370 0.29 6.0 none Bug Screen New Left (E) 9.0 0.370 0.29 norie none Bug Screen New Left (E) 9.0 0.370 0.29 none none Bug Screen New Left (E) 12.0 0.370 ' 0.29 none none Bug Screen New Left (E) 12.0 0.370 0.29 none none Bug Screen New Left (SE) 5.0 0.370 0.29 none none Bug Screen New Left (SE) 42.0 0.370 0.29 8.0 none Bug Screen New Rear (SM 42.0 0.370 0.29 18.0 none Bug Screen New Rear (SVV) 42.0 0.370 0.29 18.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 20.7 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 20.7 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 20.7 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Zone #4 Ducted Ducted Conditioned 6.0 New Zone #5 Ducted Ducted Conditioned 6.0 New Zone #6 Ducted Ducted Conditioned 6.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Energ Pro 5.1 by Ener Soft User Number: 3665 Run Code: 2011-06-29T09:40:42 /D: Page 2 of 15 Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: Ca10ERTS, Inc Electronically Filed by Scott DeVoe and Authenticated at Ca10ERTS.com - 6/29/2011 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Evertson Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 Project Address 53-165 Humboldt Boulevard La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. FloorArea 8,354 Addition Tn/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special CavityFeatures see Part 2 of 5 Status FENESTRATION U- Orientation Area(fo Factor Exterior SHGC Overhang Sidefins Shades Status Front (N) 54.0 0.350 0.19 22.0 none Bug Screen New Front (N) 17.3 0.370 0.29 none none Bug Screen New Front (N) 24.0 0.350 0.19 18.0 none Bug Screen New Front (N) '12.0 0.350 0.36 none none Bug Screen New Front (N) 4.0 0.350 0.`36 none none Bug Screen New Front (N) 4.0 0.350 0.36 none none Bug Screen New Front (NE) 64.0 0.370 0.29 5.0 none Bug Screen New Front (NE) 10.0 0.350 0.36 none none Bug Screen New Left (SE) 10.5 0.350 0.36 30.0 none Bug Screen New Left (SE) 90.0 0.340 0.32 30.0 none Bug Screen New Rear (S) 210.0 0.340 0.32 30.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Energ Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 3 of 15 Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: Ca10ERTS, Inc Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Evertson Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 Project Address 53-165 Humboldt Boulevard La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,354 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status FENESTRATION U- Orientation Area(fiz) Factor Exterior SHGC Overhang Sidefins Shades Status Rear (S) 33.8 0.350 0.36 30.0 none 'Bug Screen New Rear (S) 4.0 0.350 0.36 - none none Bug Screen New Rear (S) 4.0 0.350 0.36 none none Bug Screen New Rear (SW) 22.8 0.350 0.36 30.0 f none Bug Screen New Rear (SM 30.3 0.370 0.29 30.0 none Bug Screen New Rear (SM 90.0 0.340 0.32 30.0 none Bug Screen New Right (W) 20.0 0.350 0.19 none none Bug Screen New Right (W) 16.0 0.370 0.29 none none Bug Screen New Right (W) 30.0 0.370 0.29 none none Bug Screen New Right ((M 30.0 0.370 0.29 none none Bug Screen New Right (tM 30.0 0.370 0.29 none none Bug Screen New HVAC SYSTEMS (fit . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number: 3665 Run Code: 2011-06-29T09:40:42 ID: Pa e 4 of 15 Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Evertson Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 Project Address 53-165 Humboldt Boulevard La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,354 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special CavityFeatures see Part 2 of 5 Status FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Right (tom 30.0 0.370 0.29 none none Bug Screen New Right 4.0 0.350 0.36 none none Bug Screen New Right (tM 4.0 0.350 0.36 none none Bug Screen New Right (149 4.0 0.350 0.36 none none Bug Screen New Right (VV) 24.0 0.350 0.19 none none Bug Screen New Right (lM 15.0 0.370 0.29 none none Bug Screen New Front (NE) 48.0 0.350 0.19 9.0 none Bug Screen New Leff (SE) 4.0 0.370 0.29 none none Bug Screen New Left (SE) 6.0 0.370 0.29 none none Bug Screen New Rear (Sly 6.0 0.370 0.29 none none Bug Screen New Right (M 6.0 0.370 0.29 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 5 of 15 Reg: 211-NO031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc Electronically Filed by Scott DeVoe and Authenticated at Ca10ERTS.com - 6/29/2011 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Evertson Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 Project Address 53-165 Humboldt Boulevard La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,354 Addition Fn/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (N) 6.0 0.370 0.29 none none Bug Screen New Front (N) 8.0 0.370 0.29- none none Bug Screen New Left (E) 8.0 0.370 0.29 none none Bug Screen New Left (E) 48.0 0.350 0.19 7.0 none Bug Screen New Right (tM 4.0 0.370 0.29 none none Bug Screen New Right (W) 4.0 0.370 0.29 none none Bug Screen New Right (W) 4.0 0.370 0.29 none none Bug Screen New Right (W) 8.0 0.370 0.29 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. 'Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number: 3665 Run Code: 2011-06-29T09:40:42 /D: Page 6 of 15 Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc Electronically Filed by Scott Devoe and Authenticated at CalCERTS.com - 6/29/2011 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Eveftson Residence Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustification and documentation submitted. The DHW System Bradford White 100 Gal is a non-NAECA large storage gas water heater. Verity DHW details. The HVAC System Zone #1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. The HVAC System Zone #4 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. The HVAC System Zone #5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. The HVAC System Zone #6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se arate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. i HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System Zone #1 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System Zone #2 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System Zone #3 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System Zone #4 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ener Pro 5.1 by Ener Soft User Number: 3665 Run Code: 201 1-06-29 70 9:40:42 ID: Pa - e 7 of 15 Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc Electronically Filed by Scott Devoe and Authenticated at Ca10ERTS.com - 6/29/2011 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Evertson Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. t HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System Zone #5 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System Zone #6 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System Zone #6 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ener Pro 5.1 by Ener Soft User Number: 3665 Run Code: 2011-06-29709:40:42 /D: Page 8 of 15 Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Evertson Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 6/29/2011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 3.70 2.85 0.85 Space Cooling 61.41 57.74 3.68 Fans 12.08 13.43 -1.35 Domestic Hot Water 4.11 2.74 1.37 Pumps 0.00 0.00 0.00 Totals 81.31 76.76 4.55 Percent Better Than Standard: 5.6% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 1,610 266 Fuel Available at Site: Natural Gas (E) 2,264 513 Raised Floor Area: 1,055 (S) 1,591 485 Slab on Grade Area: 6,592 (Vto 1,783 233 Average Ceiling Height: 12.0 Roof 8,354 0 Fenestration Average U -Factor: 0.36 TOTAL: 1,497 Average SHGC: 0.30 Fenestration/CFA Ratio: 17.9% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company BREEZE AIR CONDITIONING Address Name Scott DeVoe 6/29/2011 75-145 St. Charles Place City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone (760) 346-0855 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Andrzej W. Weber Architect Address 2276 Via Alba Name Andrzej W. Weber City/State/Zip Palm Desert, CA 92260 Phone (760) 340-3002 Signed License # Date Ener Pro 5.1 by Ener Soft User Number: 3665 Run Code: 2011-06-29709:40:42 ID: Page 9 of 15 Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2012 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Evertson Residence Building Type ® Single Family O Addition Alone O Multi Family O Existing+ Addition/Alteration Date 1612912011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavit Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Roof 1,483 0.033 Filled 270 0 New 4.2.2-A23 Zone #1 Wall 313 0.071 Filled 0 90 New 4.3.1-A 15 Zone #1 Wall 530 0.071 Filled 90 90 New 4.3.1-A15 Zone #1 Wall 28 0.071 Filled 180 90 New 4.3.1-A15 Zone #1 Wall 188 0.071 Filled 270 90 New 4.3.1-A15 Zone #1 Slab 1,483 0.730 None 0 180 New 4.4.7-A1 Zone #1 Roof 1,378 0.033 Filled 270 0 New 4.2.2-A23 Zone #2 Wall 64 0.071 Filled 0 90 New 4.3.1-A 15 Zone #2 Wall 101 0.071 Filled 45 90 New 4.3.1-A 15 Zone #2 Wall 415 0.071 Filled 90 90 New 4.3.1-A 15 Zone #2 Wall 139 0.071 Filled 1351 90 New 4.3.1-A15 Zone #2 Wall 20 0.071 Filled 180 90 New 4.3.1-A15 Zone #2 Wall 132 0.071 Filled 225 90 New 4.3.1-A 15 Zone#2 Slab 1,557 0.730 None 0 180 New 4.4.7-A1 Zone #2 Roof 3,926 0.033 Filled 270 0 New 4.2.2-A23 Zone #3 Wall 413 0.071 Filled 0 90 New 4.3.1-A15 lZone #3 FENESTRATION SURFACE DETAIL'S ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 1 Window 15.0 0.370 NFRC 0.29 NFRC 0 New Wood Clad LoIE (Oper)(33) Zone #1 2 Window 15.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad LoIE (Oper)(32) Zone #1 3 Window 15.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad LoIE (O er)(31) Zone #1 4 Window 42.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad LoIE (Oper)(27) Zone #1 5 Window 42.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(26) Zone #1 6 Window 4.0 0.350 NFRC 0.36 NFRC 90 New Wood Clad LoIE (Fix)(28) Abv. Zone #1 7 Window 4.0 0.350 NFRC 0.36 NFRC 90 New Wood Clad Lo/E (Fix)(29) Abv. Zone #1 8 Window 4.0 0.350 NFRC 0.36 NFRC 90 New Wood Clad Lo/E (Fix)(30) Abv. Zone #1 9 Window 15.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad LoIE (Oper)(22) Zone #1 10 Window 44.0 0.570 Default 0.67 Default 90 New Default Glass Block (21) Zone #1 11 Window 4.0 0.350 NFRC 0.36 NFRC 90 New Wood Clad LoIE (Fix)(23) Abv. Zone #1 12 Window 4.0 0.350 NFRC 0.36 NFRC 90 New I Wood Clad Lo/E (Fix)(24) Abv. Zone #1 13 Window 4.0 0.350 NFRC 0.36 NFRC 90 New Wood Clad LoIE (Fix)(25) Abv. Zone #1 14 Window 60.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(20) Zone #2 15 Window 9.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(19) Zone #2 16 Window 9.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(18) Zone #2 (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat 7 Wd Ove hanq Left Fin Ri ht Fin Len Hcjt LExt RExt Dist I Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 7.0 6.0 5.0 1.0 5.0 5.0 5 Bug Screen 0.76 7.0 6.0 5.0 1.0 5.0 5.0 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Buq Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 6.0 10.0 6.0 1.0 6.0 6.0 15 Bug Screen 0.76 16 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID: Pae 10 of 15 Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Evertson Residence Building Type 0 Single Family 0 Addition Alone 0 Multi Family 0 Existing+ Addition/Alteration Date 1612912011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation FactorCavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 150 0.071 Filled 45 90 New 4.3.1-A15 Zone #3 Wall 24 0.071 Filled 90 90 New 4.3.1-A 15 Zone #3 Wall 162 0.071 Filled 135 90 New 4.3.1-A15 Zone #3 Wall 1 346 0.071 Filled 180 90 New 14.3.1-A15 Zone #3 Wall 129 0.071 Filled 225 90 New 14.3.1-A 15 Zone #3 Wall 704 0.071 Filled 270 90 New 4.3.1-A 15 Zone #3 Slab 3,926 0.730 None 0 180 New 4.4.7-A1 Zone #3 Roof 512 0.033 Filled 270 0 New 4.2.2-A23 Zone #4 Wall 66 0.071 Filled 225 90 New 4.3.1-A15 Zone #4 Wall 193 0.071 Filled 270 90 New 4.3.1-A15 Zone #4 83 0.071 Filled 315 90 New 4.3.1-A15 Zone #4 Slab 1,626 0.730 None 0 180 New 4.4.7-A1 Zone #4 ,Wall Roof 534 0.033 Filled 270 0 New 4.2.2-A23 Zone #5 Wall 128 0.071 Filled 45 90 New 4.3.1-A15 Zone #5 Wall 229 0.071 Filled 135 90 New 4.3.1-A15 JZone #5 Wall 2101 0.071 Filled 2-5.710 New 4.3.1-A15 lZone #5 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 12.0 0. 3701 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(17) Zone #2 18 Window 12.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(15) Zone #2 19 Window 5.0 0.370 NFRC 0.29 NFRC 135 New Wood Clad Lo/E (Oper)(16) Zone #2 20 Window 42.0 0.370 NFRC 0.29 NFRC 135 New Wood Clad Lo/E (Oper)(14) Zone W2- 21 Window 1 42.0 0.370 NFRC 0.29 NFRC 225 New Wood Clad Lo/E (Oper)(12) Zone #2 22 Window 42.0 0.370 NFRC - 0.29 NFRC 225 New Wood Clad Lo/E (Oper)(13) Zone #2 23 Window 54.0 0.350 NFRC 0.19 NFRC 0 New Wood Clad Fr. Door (0) , Zone #3 24 Window 17.3 0.370 NFRC 0.29 NFRC 0 New Wood Clad Lo/E (Oper)(37) Zone #3 25 Window 24.0 0.350 NFRC 0.19 NFRC 0 New Wood Clad Fr. Door (N) Zone #3 26 Window 12.0 0.350 NFRC 0.36 NFRC 0 New Wood Clad Lo/E (Fix)(38) Abv.- Zone #3 27 Window 4.0 0.350 NFRC 0.36 NFRC 0 New Wood Clad Lo/E (Fix)(39) Abv. + Zone #3 28 Window 4.0 0.350 NFRC 0.36 NFRC 0 New Wood Clad Lo/E (Fix)(42) Abv. Zone #3 29 Window 64.0 0.370 NFRC 0.29 NFRC 45 New Wood Clad Lo/E (Oper)(43) Zone #3 30 Window 10.0 0.350 NFRC 0.36 NFRC 45 New Wood Clad Lo/E (Fix)(44) Abv. Zone #3 31 Window 10.5 0.350 NFRC 0.36 NFRC 135 New Wood Clad Lo/E (Fix)(11) Zone #3 32 Window 90.0 0.340 NFRC I 0.32 NFRC 135 New Wood Clad Lo/E (SGD)(1) Zone #3 (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t I Wd Ove hanq Left Fin Ri ht Fin Len H t LExt REA Dist I Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 7.0 6.0 8.0 1.0 8.0 8.0 21 Bug Screen 0.76 7.0 6.0 18.0 1.0 18.0 18.0 22 Bug Screen 0.76 7.0 6.0 18.0 1.0 18.0 18.0 23 Bug Screen 0.76 9.0 6.0 22.0 1.0 22.0 22.0 24 Bug Screen 0.76 25 Bug Screen 0.76 8.0 3.0 18.0 1.0 18.0 18.0 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 7.0 6.0 5.0 1.0 5.0 5.0 30 Bug Screen 0.76 31 Bug Screen 0.76 7.0 1.5 30.0 12.0 30.0 30.0 32 18ug Screen 0.76 10.0 9.0 30.0 12.0 30.0 30.0 Ener Pro 5.1 by Ener Sok User Number: 3665 Run Code: 2011-06-29T09:40:42 ID: Pae 11 of 15 Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Evertson Residence Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1612912011 OPAQUE SURFACE DETAILS 1 Surface Type Area U- Insulation Factor Cavit Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 44 0.071 Filled 270 90 New 4.3.1-A15 Zone #5 Wall 35 0.071 Filled 315 90 New 4.3.1-A15 Zone #5 Door 24 0.500 None 315 90 New 4.5.1-A4 Zone #5 Floor 534 0.029 R-38 0 180 New 4.4.2-A8 Zone #5 Roof 521 0.033 Filled 270 0 New 4.2.2-A23 Zone #6 Wall 175 0.071 Filled 0 90 New 4.3.1-A 15 Zone #6 Wall 223 0.071 Filled 90 90 New 4.3.1-A15 Zone #6 Wall 30 0.071 Filled 135 90 New 4.3.1-A 15 Zone #6 Wall 152 0.071 Filled 180 90 New 4.3.1-A15 Zone #6 Door 24 0.500 None 180 90 New 4.5.1-A4 Zone #6 Wall 282 0.071 Filled 270 90 New 4.3.1-A15 Zone #6 Floor 521 0.029 R-38 0 180 New 4.4.2-A8 Zone #6 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 210.0 0.340 NFRC 0.32 NFRC 180 New Wood Clad Lo/E (SGD)(J) Zone #3 34 Window 33.8 0.350 NFRC 0.36 NFRC 180 New Wood Clad Lo/E (Fix)(10) Zone #3 35 Window 4.0 0.350 NFRC 0.36 NFRC 180 New Wood Clad Lo/E (Fix)(40) Abv. Zone #3 36 Window 4.0 0.350 NFRC 0.36 NFRC 180 New Wood Clad Lo/E (Fix)(41) Abv. Zone #3 37 Window 22.8 0.350 NFRC 0.36 NFRC 225 New 1 Wood Clad Lo/E (Fix)(9) Zone #3 38 Window 30.3 0.370 NFRC 0.29 NFRC 225 New Wood Clad Lo/E (Oper)(8) Zone #3 39 Window 90.0 0.340 NFRC 0.32 NFRC 225 New Wood Clad Lo/E (SGD)(H) Zone #3 40 Window 20.0 0.350 NFRC 0.19 NFRC 270 New Wood Clad Fr. Door (F) Zone #3 41 Window 16.0 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(6) Zone #3 42 Window 30.0 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(34) Zone #3 43 Window 30.0 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(35) Zone #3 44 Window 30.0 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(36) Zone #3 45 Window 30.01 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(2) Zone #4 46 Window 4.0 0.350 NFRC 0.36 NFRC 270 New Wood Clad Lo/E (Fix)(3) Abv. Zone #4 47 Window 4.0 0.350 NFRC 0.36 NFRC 270 New Wood Clad Lo/E (Fix)(4) Abv. Zone #4 48 Window 4.0 0.350 NFRC 0.36 NFRC 270 New Wood Clad Lo/E (Fix)(5) Abv. I Zone #4 (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t I Wd Ove hanq Left Fin Ri ht Fin Len I H t LExt I RExt Dist I Len H t Dist Len Hat 33 Bug Screen 0.76 10.0 21.0 30.01 12.0 30.01 30.0 34 Bug Screen 0.76 7.0 4.8 30.01 12.0 30.01 30.0 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 7.0 3.3 30.0 12.0 30.0 30.0 38 Bug Screen 0.76 7.01 4.3 30.0 12.0 30.0 30.0 39 Bug Screen 0.76 10.01 9.0 30.0 12.0 30.0 30.0 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 1E 46 Bug Screen 0.76 47 JBug Screen 0.76 48 JBug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID: Pae 12 of 15 Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Evertson Residence Building Type 0 Single Family 0 Addition Alone 0 Multi Family 0 Existing+ Addition/Alteration Date 6/29/2011 OPAQUE SURFACE DETAILS Surface U- -Type Area Factor Insulation Joint Appendix Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 49 Window 24.0 0.350 1 NFRC 0.19 NFRC 270 New Wood Clad Fr. Door (E) Zone #4 50 Window 15.0 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(1) Zone #4 51 Window 48.0 0.350 NFRC 0.19 NFRC 45 New Wood Clad Fr. Door (W) Zone #5 52 Window 4.0 0.370 NFRC 0.29 NFRC 135 New Wood Clad Lo/E (Oper)(55) Zone #5 53 Window 1 6.0 0.370 NFRC 0.29 NFRC 135 New Wood Clad Lo/E (Oper)(54) Zone #5 54 Window 6.0 0.370 NFRC 0.29 NFRC 225 New Wood Clad Lo/E (Oper)(53) Zone #5 55 Window 6.0 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(52) Zone #5 56 Window 6.0 0.370 NFRC 0.29 NFRC 0 New Wood Clad Lo/E (Oper)(47) Zone #6 57 Window 8.0 0.370 NFRC 0.29 NFRC 0 New Wood Clad Lo/E (Oper)(46) Zone #6 58 Window 8.0 0.370 NFRC 0.29 NFRC 90 New Wood Clad Lo/E (Oper)(56) Zone #6 59 Window 48.0 0.350 NFRC 0.19 NFRC 90 New Wood Clad Fr. Door (T) Zone #6 60 Window 4.0 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(51) Zone #6 61 Window 4.0 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(50) Zone #6 62 Window 4.0 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(49) Zone #6 63 Window 8.0 0.370 NFRC 0.29 NFRC 270 New Wood Clad Lo/E (Oper)(48) Zone #6 (1) LI -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade T e SHGC Window H t Wd Ove hanq Left Fin Len H t LExt RExt Dist Len I Ri ht Fin H t Dist Len H t 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 8.0 6.0 9.0 1.0 9.0 9.0 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Btkq Screen 0.76 58 Bug Screen 0.76 59 Bug Screen 0.76 8.0 6.0 7.0 1.0 7.0 7.0 60 Bug Screen 0.76 61 Bug Screen 0.76 62 Bug Screen 0.76 63 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Pae 13 of 15 Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc Electronically Filed by Scott Devoe and Authenticated at CaICERTS.com - 6/29/2011 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Evertson Residence Building Type la Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existinq Altered Removed Volume Year Built Zone #1 Mst. Bedroom 1,483 16,313 Zone #2 Office / Guest Bed 2 & 3 1,378 14,469 Zone #3 Grt. Rm / Kit. / Dining 3,926 54,964 Zone #4 Guest Bed 4 512 5,120 Zone #5 Casita / Guest Bed 5 534 4,806 Zone #6 Casita / Guest Bed 6 521 4,689 Totals 8,354 0 +0— 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Type Min. Eff. Thermostat Type Status Zone #1 1 Central Furnace --Cooling 80% AFUE Split Air Conditioner 16.2 SEER Setback New Zone #2 1 Central Furnace 80% AFUE Split Air Conditioner 16.2 SEER Setback New Zone #3 3 Central Furnace 80% AFUE Split Air,, Conditioner .16.2 SEER Setback New Zone #4 1 Central Furnace 80% AFUE Split i41r Conditioner 120.7 SEER Setback New Zone #5 1 Central Furnace 80% AFUE Split Air Conditioner 1 r20.7 SEER Setback New HVAC DISTRIBUTION System Name Heating .:, ,aDuct.r '" V Coolin Duct Location R -Value Ducts' ` Tested? Status Zone #1 Ducted Ducted Conditioned 6.0 m New Zone #2 Ducted Ducted Conditioned 6.0 m New Zone #3 Ducted Ducted Conditioned 6.0 New Zone #4 Ducted Ducted I Conditioned 6.01 New Zone #5 Ducted Ducted Conditioned 601 INew WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White 100 Gal 2 Large Gas Kitchen Pipe Ins 85,000 100 0.80 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft � 0 m CQ System Name Pipe Pipe Diameter Insul. Thick. Qt . HP Plenum Outside Buried O _Length Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID: Pae 14 of 15 Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc Electronically Filed by Scott Devoe and Authenticated at CalCERTS.com - 6/29/2011 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Evertson Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/29/2011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built Totals 8,3541 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff, Thermostat Type Status Zone #6 1 Central Furnace 80% AFUE Split Air Conditioner 20.7 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status Zone #6 Ducted Ducted Conditioned 6.0 IZ New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft c: o 75 Q75 — System Name Pipe Length Pipe Diameter Insul. Thick. . Qt HP Plenum Outside Buried ❑ Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID: Pae 15 of 15 Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc