11-0611 (SFD) Revision 1 Title 24I BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Evertson Residence
53-165 Humboldt Boulevard
La Quinta, CA 92253
Project Designer:
Andrzej W. Weber Architect
2276 Via Alba
Palm Desert, CA 92260
(760) 340-3002
Report Prepared by:
Scott DeVoe
BREEZE AIR CONDITIONING
ti
75-145 St. Charles Place CITY OF � QUINT
Palm Desert, CA 92211 A
(760) 346-0855 BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DA rE 2611 BY
%4 -
Job Number:
FH 5 2011
Date: By
6/29/2011
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29709:40:42 /D:
TABLE OF CONTENTS
Cover Page*
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
Room Load Summary
Room Heating Peak Loads
Room Cooling Peak Loads
EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 3665
1
2
3
18
21
27
33
39
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Evertson Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
Project Address
53-165 Humboldt Boulevard La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
8,354
Addition
n/a
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features see Part 2 of 5 Status
Roof Wood Framed Rafter Filled 8,354 New
Wall Wood Framed Filled 5,701. New
Slab Unheated Slab -on -Grade None 8,592 Perim = 547' New
Door Opaque Door None 24 New
Floor Wood Framed w/o Crawl Space R-38 1,055 New
Door Opaque Door None 24 New
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Front (N) 15.0 0.370 0.29 none none Bug Screen New
Left (E) 15.0 0.370 0.29 none none Bug Screen New
Left (E) 15.0 0.370 0.29 none none Bug Screen New
Left (E) 42.0 0.370 0.29 5.0 none Bug Screen New
Left (E) 42.0 0.370 0.29 5.0 none Bug Screen New
Left (E) 4.0 0.350 0.36 none none Bug Screen New
Left (E) 4.0 0.350 0.36 none none Bug Screen New
Left (E) 4.0 0.350 0.36 none none Bug Screen New
Left (E) 15.0 0.370 0.29 none none Bug Screen New
Left (E) 44.0 0.570 0.67 none none Bug Screen New
Left (E) 4.0 0.350 0.36 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 16.2 SEER Setback New
1 Central Furnace 80% AFUE
Split Air Conditioner 16.2 SEER Setback New
3 Central Furnace 80% AFUE
Split Air Conditioner 16.2 SEER Setback New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
Zone #1 Ducted
Ducted Conditioned 6.0 New
Zone #2 Ducted
Ducted Conditioned 6.0 New
Zone #3 Ducted
Ducted Conditioned 6.0 New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
2 Large Gas 100
0.80 Kitchen Pipe Ins New
Ener Pro 5.1 by Energ Soft User Number: 3665
RunCode: 2011-06-29709:40:42 ID:
Page 3 -of -4-71
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Evertson Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
Project Address
53-165 Humboldt Boulevard
La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
8,354
Addition
n/a
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features see Part 2 of 5 Status
FENESTRATION
Orientation Area(ft)
U- Exterior
Factor SHGC Overhang Sidefins Shades Status
Left (E) 4.0
0.350 0.36 none none Bug Screen New
Left (E) 4.0
0.350 0.36 none none Bug Screen New
Left (E) 60.0
0.370 0.29 6.0 none Bug Screen New
Left (E) 9.0
0.370 0.29 none none Bug Screen New
Left (E) 9.0
0.370 0.29 none none Bug Screen New
Left (E) 12.0
0.370 0.29 • none none Bug Screen New
Left (E) 12.0
0.370 0.29 none none Bug Screen New
Left (SE) 5.0
0.370 0.29 none none Bug Screen New
Left (SE) 42.0
0.370 0.29 8.0 none Bug Screen New
Rear (SIM 42.0
0.370 0.29 18.0 none Bug Screen New
Rear (SK9. 42.0
0.370 0.29 18.0 none Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace
80% AFUE Split Air Conditioner 20.7 SEER Setback New
1 Central Furnace
80% AFUE Split Air Conditioner 20.7 SEER Setback New
1 Central Furnace
80% AFUE Split Air Conditioner 20.7 SEER Setback New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
Zone #4 Ducted
Ducted Conditioned 6.0 New
Zone #5 Ducted
Ducted Conditioned 6.0 New
Zone #6 Ducted
Ducted Conditioned 6.0 New
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID:
Page 4 of 47
PERFORMANCE CERTIFICATE: Resideritial Part 1 of 5
CF-1 R
Project Name
Evertson Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
Project Address
53-165 Humboldt Boulevard La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
8,354
Addition
n/a
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity (ft) Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Front (N) 54.0 0.350 0.19 22.0 none Bug Screen New
Front (N) 17.3 0.370 0.29 none none Bug Screen New
Front (N) 24.0 0.350 0.19 18.0 none Bug Screen New
Front (N) 12.0 0.350 0.36 none none Bug Screen New
Front (N) 4.0 0.350 0.36 none none Bug Screen New
Front (N) . 4.0 0.350 0.36 none none Bug Screen New
Front (NE) 64.0 0.370 0.29 5.0 none Bug Screen New
Front (NE) 10.0 0.350 0.36 none none Bug Screen New
Left (SE) 10.5 0.350 0.36 30.0 none Bug Screen New
Left (SE) 90.0 0.340 0.32 30.0 none Bug Screen New
Rear (S) 210.0 0.340 0.32 30.0 none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by Energ Soft User Number. 3665 RunCode: 2011-06-29T09:40:42 ID:
Page 5 of 47
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Evertson Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
Project Address
53-165 Humboldt Boulevard La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
8,354
Addition
n/a
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special .
Cavity (ft) Features see Part 2 of 5 Status
FENESTRATION U-
Orientation Area(ft) Factor
Exterior
SHGC Overhang Sidefins Shades Status
Rear (S) 33.8 0.350
0.36 30.0 none Bug Screen New
Rear (S) 4.0 0.350
0.36 none none Bug Screen New
Rear (S) 4.0 0.350
0.36 none none Bug Screen New
Rear (SM 22.8 0.350
0.36 30.0 none Bug Screen New'
Rear (SlM 30.3 0.370
0.29 30.0 none Bug Screen New
Rear (SlM 90.0 0.340
0.32 30.0 none Bug Screen New
Right (lM 20.0 0.350
0.19 none none Bug Screen New
Right (lM 16.0 0.370
0.29 none none Bug Screen New
Right (lM 30.0 0.370
0.29 none none Bug Screen New
Right (lM 30.0 0.370
0.29 none none Bug Screen New
Right (lM 30.0 0.370
0.29 none none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
M
Energ Pro 5.1 by Energ Soft User Number. 3665 RunCode: 2011-06-29709:40:42 ID:
Page 6 of 47
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Evertson Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
Project Address
53-165 Humboldt Boulevard La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
8,354
Addition
n/a
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity (ft) Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Right (tM 30.0 0.370 0.29 none none Bug Screen New
Right (tM 4.0 0.350 0.36 none ' none Bug Screen New
Right (l q 4.0 0.350 0.36 none none Bug Screen New
Right (149 4.0 0.350 0.36 none none Bug Screen New
Right (149 24.0 0.350 0.19 none none Bug Screen New
Right (I49 15.0 0.370. 0.29 none' none Bug Screen New
Front (NE) 48.0 0.350 0.19 9.0 none Bug Screen New
Left (SE) 4.0 0.370 0.29 none none Bug Screen New
Left (SE) 6.0 0.370 0.29 none none Bug Screen New
Rear (SK9 6.0 0.370 0.29 none none Bug Screen New
Right (tq 6.0 0.370 0.29 none none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID:
Page 7 of 47
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF-1 R
Project Name
Evertson Residence
Project Address
53-165 Humboldt Boulevard La Quinta
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
California Energy Climate Zone Total Cond. Floor Area Addition
CA Climate Zone 15 8,354 n/a
Date
6/29/2011
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures --If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features --If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type' Cavit (ft) Features see Part 2 of 5
Status
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades
Status
Front (N) 6.0 0.370 0.29 none none Bug Screen
New
Front (N) 8.0 0.370 0.29 none none Bug Screen
New
Left (E) 8.0 0.370 0.29 none none Bug Screen
New
Left (E) 48.0 0.350 0.19 7.0 none Bug Screen
New
Right (149 4.0 0.370 0.29 none none Bug Screen
New
Right (W) 4.0 0.370 0.29 none none Bug Screen
New
Right (lM 4.0 0.370 0.29 none none Bug Screen
New
Right (W) 8.0 0.370 0.29 none none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat
Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value
Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution
Status
Energ Pro 5.1 by Energ Soft User Number: 3665 RunCode: 2011-06-29T09:40:42 /D:
Page 8 of 47
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Evertson Residence
Building Type ® Single Family ❑ Addition Alone
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
Date
I 6/29/2011
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The DHW System Bradford White 100 Gal is a non-NAECA large storage gas water heater. Verify DHW details.
The HVAC System Zone #1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
The HVAC System Zone #4 must serve only Sleeping Areas. . The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
The HVAC System Zone #5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
The HVAC System Zone #6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -413 form for each of the measures listed below for final to be given.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System Zone #1 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually
verify the installation of the HVAC unit and all Ducts and Plenums.
The HVAC System Zone #1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System Zone #2 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually
verify the installation of the HVAC unit and all Ducts and Plenums.
The HVAC System Zone #2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System Zone #3 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually
verify the installation of the HVAC unit and all Ducts and Plenums.
The HVAC System Zone #3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System Zone #4 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually
verify the installation of the HVAC unit and all Ducts and Plenums.
The HVAC System Zone #4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 9 of 47
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Evertson Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System Zone #5 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually
verify the installation of the HVAC unit and all Ducts andPlenums.
The HVAC System Zone #5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System Zone #6 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually
verify the installation of the HVAC unit and all Ducts and Plenums.
The HVAC System Zone #6 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
Ener Pro 5.1 by Ener Soft User Number 3665 RunCode: 2011-06-29T09:40:42 ID: Pae 10 of 47
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Evertson Residence
❑ Multi Family ❑ Existing+ Addition/Alteration
6/29/2011
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 3.70 2.85 0.85
Space Cooling 61.41 57.74 3.68
Fans 12.08 13.43 -1.35
Domestic Hot Water 4.11 2.74 1.37
Pumps 0.00 0.00 0.00
Totals 81.31 76.76 4.55
Percent Better Than Standard: 5.6%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (N) 1,610 266
Fuel Available at Site: Natural Gas (E) 2,264 513
Raised Floor Area: 1,055 (S) 1,591 485
Slab on Grade Area: 8.592 (W) 1,783 233
Average Ceiling Height: 12.0 Roof 8,354 0
Fenestration Average U -Factor: 0.36 TOTAL: 1.497
Average SHGC: 0.30 Fenestration/CFA Ratio: 17.9
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency.Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company BREEZE AIR CONDITIONING
612912011
Address 75-145 St. Charles Place Name Scott Devoe
City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone (760) 346-0855 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design;
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Andrzej W. Weber Architect
F
Address 2276 Via Alba Name Andrzej W. Weber
City/State/Zip Palm Desert, CA 92260 Phone (760) 340-3002Signed License # ate
Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Pae 11 of 47
CERTIFICATE OF COMPLIANCE:
Residential Part 4 of 5 CF -1 R
Project Name
Evertson Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
OPAQUE SURFACE DETAILS
Surface
Type Area
-U- Insulation
Factor Cavity Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Roof
1,483
0.033 Filled
270
0 New 4.2.2-A23
Zone #1
Wall
313
0.071 Filled
0
90 New - 4.3.1-A15
Zone #1
Wall
530
0.071 Filled
90
90 New 4.3.1-A15
Zone #1
Wall
28
0.071 Filled
180
90 New 4.3.1-A 15
Zone #1
Wall
1881
0.071 Filled
270
90 New 4.3.1-A 15
Zone #1
Slab
1,483
0.730 None
0
180 New 4.4.7-A1
Zone #1
Roof
1,378
0.033 Filled
270
0 New 4.2.2-A23
Zone #2
Wall
64
0.071 Filled
0
90 New 4.3.1-A15
Zone #2
Wall
101
0.071 Filled
45
90 New 4.3.1-A15
Zone #2
Wall
415
0.071 Filled
90
90 New 4.3.1-A15
Zone #2
Wall
139
0.071 Filled
135
90 New 4.3.1-A15
Zone #2
Wall
20
0.071 Filled
180
90 New 4.3.1-A15
Zone #2
Wall
132
0.071 Filled
225
90 New 4.3.1-A15
Zone #2
Slab
1,557
0.730 None
0
180 New 4.4.7-A1
Zone #2
Roof
3,926
0.033 Filled
270
0 New 4.2.2-A23
Zone #3
Wall
413
0.071 Filled
0
90 New 4.3.1-A 15
Zone #3
FENESTRATION SURFACE DETAILS
ID
Type
Area LI -Factor'
SHGC
Azm Status
Glazing Type
Location/Comments
1
Window
15.0 0.370 NFRC
0.29 NFRC
0 New
Wood Clad Lo/E (Oper)(33)
Zone #1
2
Window
15.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad Lo/E (Oper)(32)
Zone #1
3
Window
15.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad Lo/E O er 31
Zone #1
4
Window
42.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad Lo/E (Oper)(27)
Zone #1
5
Window 1
42.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad Lo/E (Oper)(26)
Zone #1
6
Window
4.0 0.350 NFRC
0.36 NFRC
90 New
Wood Clad Lo/E (Fix)(28) Abv.
Zone #1
7
Window
4.0 0.350 NFRC
0.36 NFRC
90 New
Wood Clad Lo/E (Fix)(29) Abv.
Zone #1
8
Window
4.0 0.350 NFRC
0.36 NFRC
90 New
Wood Clad Lo/E (Fix)(30) Abv.
Zone #1
9
Window
15.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad Lo/E (Oper)(22)
Zone #1
10
Window
44.0 0.570 Default
0.67 Default
90 New
Default Glass Block (21)
Zone #7-
11
Window
4.0 0.350 NFRC
0.36 NFRC
90 New
Wood Clad Lo/E (Fix)(23) Abv.
Zone #1
12
Window
4.0 0.350 NFRC
0.36 NFRC
90 New
Wood Clad Lo/E (Fix)(24) Abv.
Zone #1
13
Window
4.0 0.350 NFRC
0.36 NFRC
90 New
Wood Clad Lo/E (Fix)(25) Abv.
Zone #1
14
Window
60.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad Lo/E (Oper)(20)
Zone #2
15
Window
9.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad Lo/E (Oper)(19)
Zone #2
16
lWindow
9.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad Lo/E (Oper)(18)
Zone #2
(1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hanq Left Fin Ri ht Fin
Len H t . LExt RExt Dist Len H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
7.0 6.0
5.0 1.0
5.0 5.0
5
Bug Screen
0.76
7.0 6.0
5.0 1.0
5.01 5.0
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
6.0 10.0
6.0 1.0
6.0 6.0
15
IBug, Screen
i 0.76
16
IBug Screen
0.76
Ener
Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID:
Pae 12 of 47
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Evertson Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation
Factor Cavity Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Wall
150
0.071 Filled
45
90 New 4.3.1-A 15
Zone #3
Wall
24
0.071 Filled
90
90 New 4.3.1-A 15
Zone #3
Wall
162
0.071 Filled
135
90 New 4.3.1-A 15
Zone #3
Wall
346
0.071 Filled
180
90 New 4.3.1-A 15
Zone #3
Wall
129
0.071 Filled
225
90 New 4.3.1-A 15
Zone #3
Wall
704
0.071 Filled
270
90 New 4.3.1-A 15
Zone #3
Slab
3,926
0.730 None
0
180 New 4.4.7-A1
Zone #3
Roof
512
0.033 Filled
270
0 New 4.2.2-A23
Zone #4
Wall
66
0.071 Filled
225
90 New 4.3.1-A 15
Zone #4
Wall
193
0.071 Filled
270
90 New 4.3.1-A 15
Zone #4
Wall
83
0.071 Filled
315
90 New 4.3.1-A 15
Zone #4
Slab
1,626
0.730 None
0
180 New 4.4.7-A1
Zone #4
Roof
534
0.033 Filled
270
0 New 4.2.2-A23
Zone #5
Wall
128
0.071 Filled
45
90 New 4.3.1-A15
Zone #5
Wall
229
0.071 Filled
135
90 New 4.3.1-A15
Zone #5
Wall
210
0.071 Filled
225
90 New 4.3.1-A15
Zone #5
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm Status Glazing Type
Location/Comments
17
Window
12.0 0.370 NFRC
0.29 NFRC 90 New
Wood Clad Lo/E (Oper)(17)
Zone #2
18
Window
12.0 0.370 NFRC
0.29 NFRC 90 New
Wood Clad Lo/E (Oper)(15)
Zone #2
19
Window
5.0 0.370 NFRC
0.29 NFRC 135 New
Wood Clad Lo/E O er 16
Zone #2
20
Window
42.0 0.370 NFRC
0.29 NFRC 135 New
Wood Clad Lo/E (Oper)(14)
Zone #2
21
Window
42.0 0.370 NFRC
0.29 NFRC 225 New
Wood Clad Lo/E (Oper)(12)
Zone #2 _
22
Window
42.0 0.370 NFRC
0.29 NFRC 225 New
Wood Clad Lo/E (Oper)(13)
Zone #2
23
Window
54.0 0.350 NFRC
0.19 NFRC 0 New
Wood Clad Fr. Door (0)
Zone #3
24
Window
17.3 0.370 NFRC
0.29 NFRC 0 New
Wood Clad Lo/E (Oper)(37)
Zone #3
25
Window
24.0 0.350 NFRC
0.19 NFRC 0 New
Wood Clad Fr. Door (N)
Zone #3
26
Window
12.0 0.350 NFRC
0.36 NFRC 0 New
Wood Clad Lo/E (Fix)(38) Abv.
Zone #3
27
Window
4.0 0.350 NFRC
0.36 NFRC 0 New
Wood Clad Lo/E (Fix)(39) Abv.
Zone #3
28
lWindow
4.0 0.350 NFRC
0.36 NFRC 0 New
Wood Clad Lo/E (Fix)(42) Abv.
Zone #3
29
Window
64.0 0.370 NFRC
0.29 NFRC 45 New
Wood Clad Lo/E (Oper)(43)
Zone #3
30
Window
10.0 0.350 NFRC
0.36 NFRC 45 New
Wood Clad Lo/E (Fix)(44) Abv.
Zone #3
31
Window
10.5 0.350 NFRC
0.36 NFRC 135 New
Wood Clad Lo/E (Fix)(11)
Zone #3
32
Window
90.01 0.340 NFRC
0.32 NFRC 135 New
Wood Clad Lo/E (SGD)(1)
Zone #3
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hanq Left Fin Ri ht Fin
Len H t I LExt RExt Dist Len H t Dist Len H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
7.0 6.0 8.0 1.0
8.0 8.0
21
Bug Screen
0.76
7.0 6.0 18.01 1.0
18.0 18.0
22
Bug Screen
0.76
7.0 6.0 18.0 1.0
18.0 18.0
23
Bug Screen
0.76
9.0 6.0 22.0 1.0
22.0 22.0
24
Bug Screen
0.76
25
Bug Screen
0.76
8.01 3.0 18.0 1.0
18.0 18.0
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
7.0 6.0 5.0 1.0
5.0 5.0
30
Bug Screen
0.76
31
Bug Screen
0.76
7.0 1.5 30.0 12.0
30.0 30.0
32
JBug Screen
0.76
10.0 9.0 30.0 12.0
30.0 30.0
Ener
Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID:
Pae 13 of 47
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Evertson Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1612912011
OPAQUE SURFACE DETAILS
Surface
Type Area
Ll- Insulation
Factor Cavi Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Wall
44
0.071 Filled
270
90 New 4.3.1-A 15
Zone #5
Wall
35
0.071 Filled
315
90 New 4.3.1-A 15
Zone #5
Door
24
0.500 None
315
90 New 4.5.1-A4
Zone #5
Floor
534
0.029 R-38
0
180 New 4.4.2-A8
Zone #5
Roof
521
0.033 Filled
270
0 New 4.2.2-A23
Zone #6
Wall
175
0.071 Filled
0
90 New 4.3.1-A15
Zone #6.
Wall
223
0.071 Filled
90
90 New 4.3.1-A15
Zone #6
Wall
30
0.071 Filled
135
90 New 4.3.1-A 15
Zone #6
Wall
152
0.071 Filled
180
90 New 4.3.1-A 15
Zone #6
Door
24
0.500 None
180
90 New 4.5.1-A4
Zone #6
Wall
282
0.071 Filled
270
90 New 4.3.1-A 15
Zone #6
Floor
521
0.029 R-38
0
180 New 4.4.2-A8
Zone #6
FENESTRATION SURFACE DETAILS
ID
Type
Area Ll -Factor
SHGC
Azm Status Glazing Type
Location/Comments
33
Window
210.0 0.340 NFRC
0.32 NFRC 180 New
Wood Clad Lo/E (SGD)(J)
Zone #3
34
Window
33.8 0.350 1 NFRC
0.36 NFRC 180 New
Wood Clad Lo/E (Fix)(10)
Zone #3
35
Window
4.0 0.350 NFRC
0.36 NFRC 180 New
Wood Clad Lo/E Fix 40 Abv.
Zone #3
36
Window
4.0 0.350 NFRC
0.36 NFRC 180 New
Wood Clad Lo/E (Fix)(41) Abv.
Zone #3
37
Window
22.8 0.350 NFRC
0.36 NFRC 225 New
Wood Clad Lo/E (Fix)(9)
Zone #3
38
Window
30.3 0.370 NFRC
0.29 NFRC 2251 New
Wood Clad Lo/E (Oper)(8)
Zone #3
39
Window
90.0 0.340 NFRC
0.32 NFRC 225, New
Wood Clad Lo/E (SGD)(H)
Zone #3
40
Window
20.0 0.350 1 NFRC
0.19 NFRC 270 1 New
Wood Clad Fr. Door (F)
Zone #3
41
Window
16.0 0.370 NFRC
0.29 NFRC 270 New
Wood Clad Lo/E (Oper)(6)
Zone #3
42
Window
30.0 0.370 NFRC
0.29 NFRC 270 New
Wood Clad Lo/E (Oper)(34)
Zone #3
43
Window
30.0 0.370 NFRC
0.29 NFRC 270 New
Wood Clad Lo/E (Oper)(35)
Zone #3
44
Window
30.0 0.370 NFRC
0.29 NFRC 270 New
Wood Clad Lo/E (Oper)(36)
Zone #3
45
Window
30.0 0.370 NFRC
0.29 NFRC 270 New
Wood Clad Lo/E (Oper)(2)
Zone #4
46
Window
4.0 0.350 NFRC
0.36 NFRC 270 New
Wood Clad Lo/E (Fix)(3) Abv.
Zone #4
47
Window
4.0 0.350 NFRC
0.36 NFRC 270 New
Wood Clad Lo/E (Fix)(4) Abv.
Zone #4
48
Window
4.0 0.350 NFRC
0.36 NFRC 270 New
Wood Clad Lo/E (Fix)(5) Abv.
Zone #4
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t I Wd
Ove hanq Left Fin Ri ht Fin
Len H t LExt REA Dist Len H t Dist Len H t
33
Bug Screen
0.76
10.01 21.0 30.0 12.0
30.0 30.0
34
Bug Screen
0.76
7.01 4.8 30.0 12.0
30.0 30.0
35
Bug Screen
0.76
36
Bug Screen
0.76
37
- Bug Screen
0.76
7.0 3.3
30.0 12.0
30.0 30.0
38
Bug Screen
0.76
7.0 4.3
30.0 12.0
30.0 30.0
39
Bug Screen
0.76
10.0 9.0 30.01 12.0
30.01 30.0
40
Bug Screen
0.76
41
Bug Screen
0.76
42
Buq Screen
0.76
43
Bug Screen
0.76
44
Bug Screen
0.76
45
Bug Screen
0.76
46
Bug Screen
0.76
47
JBug Screen
0.76
48
IBua Screen
0.761
1
Ener
Pro 5.1 by Ener Soft User Number: 3665 Runcode: 2011-06-29709:40:42 ID:
Pae 14 of 47
CERTIFICATE OF COMPLIANCE: Residential . Part 4 of 5 CF -1 R
Project Name Building Type m Single Family ❑ Addition Alone Date
Evertson Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 1612912011
OPAQUE SURFACE DETAILS
Surface U Insulation Joint Appendix
Type I Area I Factor I Cavity Exterior I Frame I Interior Frame Azm I Tilt I Status 1 4 1 Location/Comments
FEN
ID
49
ID
49
156
N SURFACE DETAILS
Area
U -Factor
24.0
0.350 NFRC
15.0
0.370 NFRC
48.0
0.350 NFRC
4.0
0.370 NFRC
6.0
0.370 NFRC
6.0
0.370 NFRC
6.0
0.370 NFRC
6.0
0.370 NFRC
8.0
0.370 NFRC
8.0
0.370 NFRC
48.0
0.350 NFRC
4.0
0.370 NFRC
4.0
0.370 NFRC
4.01
0.370 NFRC
(1) LI -Factor Type:
(2) SHGC Type:
116-A = Defau
116-B = Defau
'ERIOR SHADING DETAILS
Exterior Shade Type
SHGC
Bug Screen
0.76
Bug Screen
0.76
Bug Screen
0.76
Bug Screen
0.76
Bug Screen
0.76
Bug Screen
0.76
Bug Screen
0.76
Bug Screen
0.76
Bug Screen
0.76
Bug Screen
0.76
Bug Screen
0.76
Bug Screen
0.76
Bug Screen
0.76
Bug Screen
0.76
Bug Screen
0.76
SHGC`
Azm Status
0.19 NFRC
270 New
0.29 NFRC
270 New
0.19 NFRC
45 New
0.29 NFRC
135 New
0.29 NFRC
135 New
0.29 NFRC
2251 New
0.29 NFRC
270 New
0.29 NFRC
0 New
0.29 NFRC
0 New
0.29 NFRC
90 New
0.19 NFRC
90 New
0.29 NFRC
270 New
0.29 NFRC
2701 New
0.29 NFRC
270 New
0.29 NFRC
270 New
Table from Standards, NFRC = Labeled
Table from Standards, NFRC = Labeled
Window
Overhana
Wood Clad Fr. Door
Wood Clad Lo/E (OF
Wood Clad Fr. Door
Wood Clad Lo/E (OF
Wood Clad Lo/E (OF
Wood Clad Lo/E (Of
Wood Clad Lo/E (Of
Wood Clad Lo/E (Of
Wood Clad Lo/E (Of
Wood Clad WE (Of
Wood Clad Fr. Door
Wood Clad Lo/E (Of
Wood Clad Lo/E (OF
Wood Clad WE (04
LEA I RExt
1.01 9.01 9.0
6.01 7.01 1.01 7.01 7
Left Fin
Zone #4
Zone #4
Zone #5
Zone #5
Zone #5
Zone #5
Zone #5
Zone #6
Zone #6
Zone #6
Zone #6
Zone #6
Zone #6
Zone #6
Zone #6
ents
it Fin
nT
EnerPro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29T09:40:42 /D: Page 15 of 47
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF -1 R
Project Name
Evertson Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
113/2.c)/2011
BUILDING ZONE INFORMATION
System Name
Zone Name
Floor Area ft
New Existing Altered Removed Volume
Year Built
Zone #1 Mst. Bedroom
1,483
16,313
.
Zone #2 Office / Guest Bed 2 & 3
1,378
14,469
Zone #3 Grt. Rm /Kit. /Dining
3,926
54,964
Zone #4 Guest Bed 4
512
5,120
Zone #5 Casita / Guest Bed 5
534
4,806
Zone #6 Casita / Guest Bed 6
521
4,689
Totals 1 8,354 01 01 0
HVAC SYSTEMS
System Name Qty. Heatinq Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type
Status
Zone #1
1 Central Furnace
80% AFUE Split Air Conditioner 16.2 SEER Setback
New
Zone #2
1 Central Furnace
80% AFUE Split Air Conditioner 16.2 SEER Setback
New
Zone #3
3 Central Furnace
80% AFUE Split Air Conditioner 16.2 SEER Setback
New
Zone #4
1 Central Furnace
80% AFUE Split Air Conditioner 20.7 SEER Setback
New
Zone #5
1 Central Furnace
80% AFUE Split Air Conditioner 70.7 SEER Setback
New
HVAC DISTRIBUTION
System Name
Heating
Duct
Cooling Duct Location. R -Value
Ducts
Tested? Status
Zone #1 Ducted
Ducted Conditioned 6.0
m
New
Zone #2 Ducted
Ducted Conditioned 6.0
m
New
Zone #3 Ducted
Ducted Conditioned 6.0
16
New
Zone #4 Ducted
Ducted Conditioned 6.0
0
INew
Zone #5 Ducted
Ducted Conditioned 6.01
m
INew
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Bradford White 100 Gal
2
Large Gas
Kitchen Pipe Ins
85,000
100
0.80
0.00%
0.0
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
ft
C
0
ro
Q —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qt . HP
Plenum Outside Buried
Ener Pro 5.1 by Ener Soft
User Number: 3665
RunCode: 2011-06-29709:40:42 ID:
Pae 16 of 47
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF -1 R
Project Name
Evertson Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ft
New Existinq Altered Removed Volume Year Built
Totals 1 8,3541 01 OF 0
HVAC SYSTEMS
System Name Qty. Heatin Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Zone #6 1 Central Furnace
80% AFUE Split Air Conditioner 20.7 SEER Setback
New
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
Zone #6 Ducted
Ducted Conditioned 6.0
m New
WATER HEATING SYSTEMS
S stem Name
aty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
ft
c
0
i�
Q —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty.THP
Plenum Outside Buried
Ener Pro 5.1 by Ener Soft User Number: 3665
RunCode: 2011-06-29709:40:42 ID:
Pae 17 of 47
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Evertson Residence
Date
6/29/2011
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leaka e.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i):The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1R Form.
*§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent LI -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
§150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected.frorn physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise_ residential occupancies meet the air release
valve, backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-13.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
§150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID: Page 18 of 47
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R
Project Name
Date
Evertson Residence
6/29/2011
§150(m)1: All air-distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply-air and return-air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure system that meets the
applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in'cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m .10: Flexible ducts cannot have porous inner cores.
§150(0): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low-Rise Residential Buildings. Window operation isnot a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
pro rammed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line-
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw-base socket.
§150(k)6: Liqhting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi-scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet,
and utility rooms are high efficacy and controlled by a
manual-on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoR User Number: 3665 RunCode: 2011-06-29709:40:42 /D: Page 19 of 47
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Evertson Residence
6/29/2011
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
_than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number.- 3665 RunCode: 2011-06-29T09:40:42 ID: Page 20 of 47
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Evertson Residence
Date
6/29/2011
System Name
Zone #1
Floor Area
1,483
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING
CFM Sensible
Total Room Loads 1,009 18,063
Return Vented Lighting 0
Return Air Ducts 378
Return Fan 0
Ventilation 273 11,570
Supply Fan 0
Supply Air Ducts 378
TOTAL SYSTEM LOAD 1 30,388
PEAK COIL HTG.
PEAK
Heating System
Latent CFM
Sensible
Output perSystem 88,000.
2,444 832
22,002
Total Output (Btuh) 88,000
Output Btuh/s ft 59.3
321
Cooling System
0
Output perSystem 59,500
5,327 273
15,645
Total Output Btuh 59,500
7,771
0
Total Output (Tons) 5.0
321
Total Output (Btuh/s ft) 40.1
Total Output s ft/Ton 299.1
38,289
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Lennox XC21/SL280UHV (5 Ton) 48,189
3,447
88,000
Airflow cfm/s ft 1.35
Airflow cfm/Ton
403.4
Outside Air (%)
13.7%
Total Adjusted System Output 48,189.
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
3,447 88,000
Aug 3 PM Jan 1 AM
Outside Air (cfm/s ft) 0.18
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 72 OF
Outside Air
AV -
273 cfm Supply Fan
AL 2,000 cfm
80 OF
72 OF 105 OF
Heating Coil
105 OF
ROOM
80 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 78/63°F 78/64°F 55/54°F
Outside Air
273 cfm Ar Supply Fan Cooling Coil 55 / 54 OF
2,000 cfm
52.6% ROOM ,w
72 / 61 OF 72 / 61 OF
EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID:
Page 21 of 47
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Evertson Residence
Date
6/29/2011
System Name
Zone #2
Floor Area
1,378
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 973
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 364
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 88,000
17,433
2,485 775
20,501
Total Output Btuh 88,000
0
Output Btuh/s ft 63:9
365
300
Cooling System
0
0
Output per System 59,500
15,429
7,167 364
20,864
Total Output (Btuh) 59,500
0
365
1 33,591
9,652
0
Total Output ons 5.0
300
Total Output (Btuh/s ft) 43.2
Total Output s ft/Ton 277.9
41,964
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Lennox XC21/SL280UHV (5 Ton) 49,892
2,4251
88,000
Airflow (cfm/s ft)
1.45
Airflow cfm/Ton) 403.4
Outside Air (%)
18.2 %
Total Adjusted System Output 49,892
(Adjusted for Peak Design conditions) .
TIME OF SYSTEM PEAK
2,425
Aug 3 PM
88,000
I Jan 1 AM
Outside Air (cfm/s ft) 0.26
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 70 OF
Outside Air
364 cfm Supply Fan
2,000 cfm
80 OF
70 OF 105 OF
Heating Coil
105 OF
Roots in
80 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 79/64°F 79/64°F 55/54°F
Outside Air _
364 cfm Supply Fan Cooling Coil 55 / 54 OF
2,000 cfm -
52.4% ROOM in
72 / 61 OF 72 / 61 OF
EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29709:40:42 /D:
Page 22 of 47
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Evertson Residence
Date
6/29/2011
System Name
Zone #3
Floor Area
3,926
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
3
COIL
CFM
Total Room Loads 2,348
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 273
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 88,000
42,142
6,340 2,075
54,936
Total Output (Btuh) 264,000
0
Output Btuh/s ft 67.2
881
803
Cooling System
0
0
Output per System 59,500
11,581
5,262 273
15,652
Total Output (Btuh) 178,500
0
881
.55,485
11,602
0
Total Output (Tons) 14.9
803
Total Output (Btuh/s ft) 45.5
Total Output s ft/Ton 263.9
1 72,193
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
6,000
Lennox XC21/SL280UHV (5 Ton) 134,638
16,104
264,000
Airflow (cfm/s ft)
1.53
Airflow cfm/Ton 403.4
Outside Air (%)
4-6%
Total Adjusted System Output 134,638
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
16,104 264,000
Aug 3 PM Jan 1 AM
Outside Air (cfm/s ft) 1 0.07
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak)
26 OF 77 OF
Outside Air
273 cfm Supply Fan
AL 6,000 cfm
80 OF
77 OF 105 OF
Heating Coil
105 OF
FROOM
80 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112 / 78 OF 74162 OF 74 / 62 OF 55 / 54 OF
o
Outside Air
273 cfm Ar Supply Fan Cooling Coil 55 / 54 OF
6,000 cfm - -
52.9% � ROOM ]"
72/61°F 72/61°F
EnergyPro 5.1 by EnergySoff User Number: 3665 RunCode: 2011-06-29T09:40:42 ID:
Page 23 of 47
HVAC SYSTEM HEATING. AND COOLING LOADS SUMMARY
Project Name
Evertson Residence
Date
6/29/2011
System Name ,
Zone #4
Floor Area
512
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING PEAK
CFM Sensible
Total Room Loads 516 9,213
Return Vented Lighting 0
Return Air Ducts 193
Return Fan 0
Ventilation 182 7,704
Supply Fan 0
Supply Air Ducts 193
TOTAL SYSTEM LOAD 1 17,301
COIL HTG. PEAK
Latent CFM Sensible
975 445 11,740
172
0
3,626 182 10,420
0
172
4,600 22,503
Heating System
Output per System 66,000
Total Output (Btuh) 66,000
Output Btuh/s ft 128.9
Cooling System
Output per system 25,600
Total Output (Btuh) 25,600
Total Output (Tons) 2.1
Total Output Btuh/s ft 50.0
Total Output s ft/Ton 240.0
Air System
CFM per System
800
HVAC EQUIPMENT SELECTION
Airflow cfm
800
Lennox XC21/SL280UHV (2 Ton) 22,352
454
66,000
Airflow (cfm/s ft) 1.56
Airflow cfm/Ton 375.0
Outside Air (%)
22.8%
Total Adjusted System Output 22,352
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
454 66,000
Aug 3 PM Jan 1 AM
Outside Air (cfm/s ft) 0.36
Note: values above givenat ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 68 °F
Outside Air
182 cfm Supply Fan
800 cfm
80 OF
68 OF 105 OF
Heating Coil
105 OF
Room
80 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 81 /65°F 81 /65°F 55154°F
Outside Air
182 cfm AL Supply Fan Cooling Coil55154
800 cfm
52.1 %
72/61 OF
4 *1 1 -.4 —0 1 1 1 -3 .4
OF
ROOM
72/61 OF
1
EnergyPro 5.1 by EnergySoft User Number. 3665 RunCode: 2011-06-29709:40:42 /D:
Page 24 of 47
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Evertson Residence
Date
6/29/2011
System Name
Zone #5
Floor Area
534
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING
CFM Sensible
Total Room Loads 357 6,398
Return Vented Lighting 0
Return Air Ducts 134
Return Fan 0
Ventilation 182 7,717
Supply Fan 0
Supply Air Ducts 134
TOTAL SYSTEM LOAD 1 14,383
PEAK COIL HTG.
PEAK
Heating System
Latent CFM
Sensible
Output per System 66,000
1,008 326
8,613
Total Output (Btuh) 66,000
Output Btuh/s ft 123.6
126
Cooling System
0
Output. per System 25,600
3,616 182
10,431
Total Output (Btuh) 25,600
4,624
0
Total Output (Tons) 2.1
126
Total Output Btuh/s ft 47.9
Total Output s ft/Ton 250.3
19,295
Air System
CFM per System
800
HVAC EQUIPMENT SELECTION
Airflow cfm
800
Lennox XC21/SL280UHV (2 Ton) 22,315
490
66,000
66,000
Jan 1 AM
Airflow (cfm/s ft) 1.50
Airflow cfm/Ton 375.0
Outside Air (%) 22.8%
Total Adjusted System Output 22,315
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
490
Aug 3 PM
Outside Air (cfm/s ft) 0.34
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 68 OF
0
Outside Air
182 cfm Supply Fan
800 cfm
80 OF
68 OF 105 OF
Heating Coil
105 OF
ROOM
80 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 81/65°F 81/65°F 55/54°F
Outside Air
182 cfm Ar Supply Fan Cooling Coil 55 / 54 OF
800 cfm 52.2% ROOM
72/61 OF 72/61 OF
EnergyPro 5.1 by EnergySoR User Number.- 3665 RunCode: 2011-06-29709:40:42 /D:
Page 25 of 47
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Evertson Residence
6/29/2011
System Name
Floor Area
Zone #6
521
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING PEAK
COIL HTG. PEAK
Heating System
CFM Sensible
Latent CFM Sensible
Out ut per System
66,000
Total Room Loads 406 7,260
988 369 9,743
Total Output (Btuh)
66,000
Return Vented Lighting 0
Output Btuh/s ft
126.7
Return Air Ducts 152
.142
Cooling System
Return Fan 0
0
Output per System
25,600
Ventilation 182 7,713
3,621 182 10,427
Total Output Btuh
25,600
Supply Fan 0
0
Total Output Tons
2.1
Supply Air Ducts 152
142
Total Output (Btuh/s ft)
49.1
TOTAL SYSTEM LOAD 15,277
4,609 20,455
Total Output s tt/Ton 244.2
Air System
CFM per System
800
HVAC EQUIPMENT SELECTION
Airflow cfm
800
Lennox XC21/SL280UHV (2 Ton) 22,329
475
66,000
Airflow (cfm/s ft) 1.54
Airflow (cfm/Ton) 375.0
Outside Air %)
22-8%
Total Adjusted System Output 22,329
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
475
Aug 3PM
66,000
Jan 1 AM
Outside Air (cfm/s ft) 0.35
Note: values above given at.ARl conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 68 OF
68 OF 105 OF
Outside Air
182 cfm Supply Fan
Heating Coil
105 OF
800 cfm
ROOM
80 OF
80 °F
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 81!65°F 81/65°F 55/54°F
0 �
Outside Air
182 cfm
Supply Fan
Cooling Coil
55 / 54 OF
800 cfm
52.1 %
.-
ROOM EQ]
72161 OF
1-4
72/61 OF
EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29709:40:42 /D:
Page 26 of 47
ROOM LOAD SUMMARY
Project Name Date
Evertson Residence 6/29/2011
System Name Floor Area
Zone #1 1,483
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name I Mult. I CFM I Sensible Latent CFM I Sensible I Latent CFM Sensible
Zone #1 Mst. Bedroom 1 1,009 18,063 2,444 1,009 18,063 2,444 832 22,002
PAGE TOTAL
TOTAL•
1,009 18,0631
2,4441
832
22, 002
1,009 18,0631
2,4441
832
22,002
Total includes ventilation load for zonal systems.
Ener Pro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 27 of 47
ROOM LOAD SUMMARY
Project Name Date
Evertson Residence 6/29/2011
System. Name Floor Area
Zone #2 1,378
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM I Sensible
Zone #2 Office / Guest Bed 2 & 3 1 1 973 17,433 2,485 973 17,433 2,485 7751 20,501
PAGE TOTAL
TOTAL*
* Total includes ventilation load for zonal
973
17,433
2,485
775 20,501
973
17,433
2,485
775 20,501
Ener Pro 5.1 by EnerqySoft User Number: 3665 RunCode: 2011-06-29709:40:42 - ID: Page 28 of 47
ROOM LOAD SUMMARY
Project Name Date
Evertson Residence 6/29/2011
System Name Floor Area
Zone #3 3,926
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Zone #3 • Grt. Rm / Kit. / Dining 1 2,3481 42,142 6,340 2,3481 42,142 6, 340 . 2,0751 54,936
PAGE TOTAL
TOTAL'
2,348
42,142
6,3401
Z0751
54,936
2,348
42,142
6,3401
2,0751
54,93
Total includes ventilation load for zonal systems.
Ener Pro 5.1 by EnerqySoft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 29 of 47
ROOM LOAD -SUMMARY -
Evertson Residence 6/29/2011
System Name Floor Area
Zone #4 512
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK
Zone Name Room Name Mult. CFM I Sensible Latent CFM I Sensible Latent I CFM I Sensible
Zone #4 Guest Bed 4 1 516 9,213 975 516 9,2131 9751 4451 11,740
PAGE TOTAL
TOTAL*
* Total includes ventilation load for zonal
516
9,213
975
445
11,740
516
9,213
975
445
11,740
of 47
ROOM LOAD SUMMARY
Project Name Date
Evertson Residence 6/29/2011
System Name Floor Area
Zone #5 534
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK
Zone Name Room Name Mult. CFM I Sensible Latent CFM I Sensible I Latent I . CFM Sensible
Zone #5 Casita /Guest Bed 5 1 1 357 6,3981 1,008 3571 6,3981 1,008 326 8,613
PAGE TOTAL
TOTAL•
57
P357
6,3981
1,0081
326
8,613
6,398
1,008
326
8,613
' Total includes ventilation load for zonal systems.
Ener Pro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 31 of 47
ROOM LOAD SUMMARY
Project Name Date
Evertson Residence 6/29/2011
System Name Floor Area
Zone #6 521
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. I CFM Sensible I Latent CFM I Sensible Latent CFM I Sensible
Zone #6 Casita / Guest Bed 6 1 1 406 7,2601 988 406 7,2601 988 369 9,743
PAGE TOTAL
TOTAL'
Total includes ventilation
406
7,260
988
369
9,743
406
7,260
988
369
9,743
ROOM HEATING PEAK LOADS
Project Name
Evertson Residence ' -
Date
7 6/29/2011
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Mst. Bedroom
Floor Area 1,483.0 ft2
Indoor Dry Bulb Temperature 80 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value
AT °F
=
=
=
=
=
-
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
54
Btu/hr
Icynene (Roof). (R-38, 10" Thk)
1,483.0
X
0.0330
X
54
2,643
Icynene (Wall) (R-21, 5.5"Thk)
1,058.0
X
X
X
0.0710
X
X
X
54
4,056
Wood Clad Lo/E (Oper)(33)
15.0
0.3700
54
300
Wood Clad Lo/E (Oper)(32)
15.0
0.3700
54
300
Wood Clad WE (Oper)(31)
15.0
X
X
0.3700
X
X
54
300
Wood Clad WE (Oper)(27)
42.0
0.3700
54
839
Wood Clad WE (Oper)(26)
42.0
X
0.3700X
54
839
Wood Clad WE (Fix)(28) Abv.
4.0
X
X
X
0.3500
X
X
X
54
76
Wood Clad Lo/E (Fix)(29) Abv.
4.0
0.3500
54
76
Wood Clad Lo/E (Fix)(30) Abv.
4.0
0.3500
54
76
Wood Clad WE (Oper)(22)
15.0
X
0.3700
X
54
300
Default Glass Block (21)
44.0
X
X
0.5700
X
X
54
1,354
Wood Clad Ld/E (Fix)(23) Abv.
4.0
0.3500
54
76
Wood Clad WE (Fix)(24) Abv.
4.0
X
X
X
0.3500
X
X
X
54
76
Wood Clad WE (Fix)(25) Abv.
4.0
0.3500
54
76
Slab -On -Grade
perim = 103.0
0.7300
54
4,060
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (') denote conduction
Infiltration:l 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 1,483 X
Area
to another room
11.00 X 0.420
Ceiling Height ACH
Page Total
/60] X
AT
15,444
= 6,557
TOTAL HOURLY HEAT LOSS FOR ROOM 22,002
EnergyPro 5.1 by EnergySoft User Number. 3665 RunCode: 2011-06-29T09:40:42 ID: Page 33 of 47
ROOM HEATING PEAK LOADS
Project Name
Evertson Residence
Date
6/29/2011
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Office / Guest Bed 2 & 3
Floor Area 1,378.0 ft2
Indoor Dry Bulb Temperature 80 OF
Time of Peak
Outdoor Dry Bulb Temperature
Jan 1 AM
26 OF
Conduction Area
Icynene (Roof) (R-38, 10" Thk) 1,378.0 X
Icynene (Wall) (R-21, 5.5" Thk) 870.0 X
Wood Clad Lo/E (Oper)(20) 60.0 X
Wood Clad Lo/E (Oper)(19) 9.0 X
Wood Clad Lo/E (Oper)(18) 9.0 X
Wood Clad Lo/E (Oper)(17) 12.0 X
Wood Clad WE (Oper) (15) 12.0 X
Wood Clad Lo/E (Oper)(16) 5.0 X
Wood Clad Lo/E (Oper)(14) 42.0 X
Wood Clad Lo/E (Oper)(12) 42.0 X
Wood Clad Lo/E (Oper)(13) 42.0 X
Slab-On-Grade perim = 100.5 X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (`) denote conduction through an interior surface to
Infiltration:[ 1.00 X 1.064 X 1,378 X
Schedule Air Sensible Area Ceiling
Fraction
U-Value
0.0330 X
0.0710 X
0.3700 X
0.3700 X
0.3700 X
0.3700 X
0.3700 X
0.3700 X
0.3700 X
0.3700 X
0.3700 X
0.7300 X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
x
X
another room
10.50 X 0.440
Height ACH
AT °F
54 =
54 =
54 =
54 =
54 =
54 =
54 =
54 =
54 =
54 =
54 =
54 =
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Page Total
/60] X 54
AT
Btu/hr
2,456
3,336
1,199
180
180
240
240
100
839
839
839
3,962
14,408
= 6,093
TOTAL HOURLY HEAT LOSS FOR ROOM
20,501
EnergyPro 5.1 by EnergySoft User Number: 3665
RunCode: 2011-06-29709:40:42
ID:
Page 34 of 47
ROOM HEATING PEAK LOADS
Project Name
Evertson Residence
ROOM INFORMATION DESIGN CONDITIONS
Room Name Grt. Rm /Kit. /Dining Time of Peak
Floor Area 3,926.0 ft' Outdoor Dry Bulb Temperature
Indoor Dry Bulb Temperature 80 OF
Conduction Area H-Vahio
Icynene (Roof) (R-38, 10" Thk)
Icynene (Wall) (R-21, 5.5".Thk)
Wood Clad Fr. Door (0)
Wood Clad Lo/E (Oper)(37)
Wood Clad Fr. Door (N)
Wood Clad Lo/E (Fix)(38) Abv.
Wood Clad Lo/E (Fix)(39) Abv.
Wood Clad Lo/E (Fix)(42) Abv.
Wood Clad Lo/E (Oper)(43)
Wood Clad Lo/E (Fix)(44) Abv.
Wood Clad Lo/E (Fix)(11)
Wood Clad Lo/E (SGD)(1)
Wood Clad Lo/E (SGD)(J)
Wood Clad Lo/E (Fix)(10) `
Wood Clad Lo/E (Fix)(40) Abv.
Wood Clad Lo/E (Fix)(41) Abv.
Wood Clad Lo/E (Fix)(9)
Wood Clad Lo/E (Oper)(8)
Wood Clad WE (SGD)(H)
Wood Clad Fr. Door (F)
Wood Clad Lo/E (Oper)(6)
Wood Clad WE (Oper)(34)
Wood Clad Lo/E (Oper)(35)
Wood Clad Lo/E (Oper)(36)
Slab -On -Grade
3,926.0
1,927.3
54.0
17.3
24.0
12.0
4.0
4.0
64.0
10.0
10.5
90.0
210.0
33.8
4.0
4.0
22.8
30.3
90.0
20.0
16.0
30.0
30.0
30.0
perim = 199.0
X
.0.0330
X
0.0710
X
0.3500
X
X
X
X
0.3700
0.3500
0.3500
0.3500
X
0.3500
X
0.3700
X
0.3500
X
0.3500
X
0.3400
X
X
X
X
0.3400
0.3500
0.3500
0.3500
X
0.3500
X
0.3700
X
0.3400
X
0.3500
X
X
X
0.3700
0.3700
0.3700
X
0.3700
X
0.7300
X
X
X
X
X
X
Items shown with an asterisk (') denote conduction through an interior surface to another room
Infiltration:[ 1.00 x 1.084 X 3,926 X 14.00 X 0.330
Schedule Air Sensible Area Ceiling Height ACH
AT °F'
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
Page Tc
/60] XC
AT
6/29/2011
Jan 1 AM
26 OF
Btu/hr
. 6, 996
7,369
1,021
346
454
c 227
c 76
76
c 1,279
c 189
198
1,652
c
3,856
639
76
76
431
605
1,652
c 378
c 320
599
599
599
7,845
tal 37,577
54 = 17,359
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 54,936
Energ Pro 5.1 by Energ Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 35 of 47
ROOM HEATING PEAK LOADS
Project Name
Evertson Residence
Date
6/29/2011
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Guest Bed 4
Floor Area 512.Oft'
Indoor Dry Bulb Temperature 80 °F
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
512.0 X
341.0 X
U -Value
0.0330 X
0.0710 X
0.3700 X
0.3500 X
AT °F
54 c
54 =
54 =
54 =
54 =
54 =
54 =
54 =
54 =
=
=
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Page Total
/ 60 � X 54
AT
Btu/hr
Icynene (RooO (R-38, 10" Thk)
912
Icynene (Wall) (R-21, 5.5" Thk)
1,307
Wood Clad Lo/E (Oper)(2)
30.0
X
X
X
X
X
599
Wood Clad WE (Fix)(3) Abv.
4.0
76
Wood Clad WE (Fix)(4) Abv.
4.0
0.3500
X
X
76
Wood Clad Lo/E (Fix)(5) Abv.
4.0
0.3500
76
Wood Clad Fr. Door (E)
24.0
0.3500
X
X
X
X
X
X
454
Wood Clad Lo/E (Oper)(1)
15.0
X
0.3700
300
Slab -On -Grade
perim = 144.0
X
X
0.7300
5,676
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (`) denote conduction
Infiltration:[ 1.00 )( 1.064
Schedule Air Sensible
Fraction
through an interior surface to
X 512 X
Area Ceiling
another room
10.00 X 0.462
Height ACH
9,476
= 2,264
TOTAL HOURLY HEAT LOSS FOR ROOM 11,740
Energ Pro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 36 of 47
ROOM HEATING PEAK LOADS
Project Name
Evertson Residence
Date
6/29/2011
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita / Guest Bed 5
Floor Area 534.0 ft2
Indoor Dry Bulb Temperature 80 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature_ 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
-
=
=
=
=
=
=
=
=
=
54
Btu/hr
Icynene (Root) (R-38, 10" Thk)
534.0
0.0330
54
952
Icynene (Wall) (R-21, 5.5"Thk)
644.0
0.0710
54
2,469
Wood Clad Fr. Door (lM
48.0
0.3500
54
907
Wood Clad Lo/E (Oper)(55)
4.0
0.3700
54
80
Wood Clad Lo/E (Oper)(54)
6.0
0.3700
54
120
Wood Clad Lo/E (Oper)(53)
6.0
0.3700
54
120
Wood Clad Lo/E (Oper)(52)
6.0
0.3700
54
120
Wood Door (V)
24.0
0.5000
54
648
Icynene (Floor) (R-38, 10" Thk)
534.0
0.0290
54
836
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 534 X
Area
another room
9.00 X 0.513
Height ACH
Page Total
/60] X
AT
6,252
= 2,361
TOTAL HOURLY HEAT LOSS FOR ROOM 8,613
EnergyPro 5.1 by EnergySoft User Number.- 3665 Runcode: 2011-06-29709:40:42 ID: Page 37 of 47
ROOM HEATING PEAK LOADS
Project Name7.612912011
Evertson Residence
ate
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita / Guest Bed 6
Floor Area 521.0 ft2
Indoor Dry Bulb Temperature 80 OF.
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
0.0330 X
0.0710 X
0.3700 X
0.3700 X
0.3700 X
0.3500 X
0.5000 X
0.3700 X
0.3700 X
0.3700 X
0.3700 X
0.0290 X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
another room
9.00 X 0.513
Height ACH
AT °F
54 =
Btu/hr
Icynene (Roof) (R-38, 10" Thk)
521.0
928
Icynene (Wall) (R-21, 5.5" Thk)
861.0
54
=
3,301
Wood Clad Lo/E (Oper)(47)
6.0
54
=
120
Wood Clad Lo/E (Oper)(46)
8.0
54
=
160
Wood Clad Lo/E (Oper)(56)
8.0
54
=
160
Wood Clad Fr. Door (T)
48.0
54
=
=
907
Wood Door (S)
24.0
54
648
Wood Clad Lo/E (Oper)(51)
4.0
54
=
=
80
Wood Clad Lo/E (Oper)(50)
4.0
54
80
Wood Clad Lo/E (Oper)(49)
4.0
54
=
80
Wood Clad Lo/E (Oper)(48)
8.0
54
=
160
Icynene (Floor) (R-38, 10" Thk)
521.0
54
=
816
=
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 521 X
Area
Page Total
/60] X 54
AT
7,440
= 2,304
TOTAL HOURLY HEAT LOSS FOR ROOM 9,743
Energ Pro 5.1 by EnergySoft User Number: 3665 RunCode: 2011-06-29709:40:42 ID: Page 38 of 47
I
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Evertson Residence 6/29/2011
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Mst. Bedroom
Outdoor Dry Bulb Temperature 112 OF
Floor Area 1,483.0 ft2
Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 72 OF
Outdoor Daily Range: 34 OF.
Opaque Surfaces Orientation
Area
U -Factor CLTD'
Btu/hr
Icynene (Root) (R-38, 10" Thk) (W)
1,483.0 X
0.0330 X 56.0
= 2,741
Icynene (Wall) (R-21, 5.5" Thk) - (N)
313.0 X
0.0710 X 23.0
= 511
Icynene (Wall) (R-21, 5.5" Thk) (E)
530.0 X
0.0710 X 33.0
= 1,242
Icynene (Wall) (R-21, 5.5" Thk) (S)
27.5 X
0.0710X 26.0
= 51
Icynene (Wall) (R-21, 5.5" Thk)
167.5 X
0.0710 X 33.0
= 439
15.0 X
- X
X
=
X
X
=
X
X
=
X
J X
=
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
I Fenestration
OperWdw (5030)(33)
OperWdw (5030)(32)
OperWdw (5030)(31)
OperWdw (6070)(27)
OperWdw (6070)(26)
FxWdw (2020) Abv.(28)
FxWdw (2020) Abv. (29)
FxWdw (2020) Abv.(30)
OperWdw (5030)(22)
Orientation
(N)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
1 4,9841
Shaded
Area
GLF
18.2 +
18.2 +
18.2 +
18.2 +
18.2 +
20.4 +
20.4 +
20.4 +
18.2 +
Unshaded
Area
15.0 X
15.0 X
GLF
18.2 =
0.0
X
X
0.0
35.4
=
0.0
X
15.0
X
X
X
35.4
=
=
=
18.0
X
X
24.0
35.4
18.0
24.0
35.4
0.0 X
0.0 X
0.0 X
0.0 X
4.0
X
X
X
41.7
=
=
4.0
41.7
4.0
41.7
=
15.0 X
Page Total
Btu/hr
272
531
531
1,176
1,176
167
167
167
531
4,7171
Internal Gain Btu/hr
Occupants 1.0 Occupants X 230 Btuh/occ. _ 230
Equipment 0.0 Dwelling Unit X 1,600 Btu - 0
Infiltration: 1.064 X 1.24 X 81.15 X 40 = 4,285
Air Sensible . CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,063
Latent Gain Btu/hr
Occupants 1.0 Occupants X 200Btuh/occ. = 200
Infiltration: 4,771 X 1.24 X 81.15 X 0.00467 = 2 P44
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
2.444
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Evertson Residence
6/29/2011
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Mst. Bedroom
Outdoor Dry Bulb Temperature
112 OF
Floor Area 1,483.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 72 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces ` Orientation Area U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
-
X
X
=
Page Total
0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area
GLF
Btu/hr '
GIsBIk (8056)(21) (E) 0.0 X 36.3 +
44.0
X 76.0
= 3,346
FxWdw (2020) Abv.(23) (E) 0.0 X 20.4 +
4.0
X 41.7
= 167
FxWdw (2020) Abv.(24) (E) 0.0 X 20.4 +
4.0
X 41.7
= 167
FxWdw (2020) Abv.(25) (E) 0.0 X 20.4 +
4.0
X 41.7
= 167
X +
X
-
X +
X
-
X +
X
-
X +
IX
-
X +
X
-
Page Total
3,847
Internal Gain
Btu/hr
Occupants 1.0 Occupants X 230
Btuh/occ.
=
230
Equipment 0.0 Dwelling Unit X 1,600
Btu
=
0
Infiltration: 1.064 )( 1.24 X 81.15 X 40 =
4,285
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
18,063
Latent Gain
Btu/hr
Occupants 1.0 Occupants X 200
Btuh/occ.
=
200
Infiltration: 4,771 X 1.24 X 81.15 X 0.00467 =
2,244
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
2,444
Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID:
Page 40 of 47
RESIDENTIAL ROWCOOLING LOAD SUMMARY
Project -Name Date
Evertson Residence 76/29/2011
ROOM INFORMATION DESIGN CONDITIONS .
Room Name Office /.Guest Bed 2 & 3 Outdoor Dry Bulb Temperature 112 °F
Floor Area 1,378.0 ft? Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature - 72 OF Outdoor Daily Range: 34 OF
Opaque Surfaces
Icynene (Roof) (R-38, 10" Thk)
Icynene (Wall) (R-21, 5.5" Thk)
Icynene (Wall) (R-21, 5.5" Thk)
Icynene (Wall) (R-21, 5.5" Thk)
Icynene (Wall) (R-21, 5.5" Thk)
Icynene (Wall) (R-21, 5.5" Thk)
Icynene (Wall) (R-21, 5.5" Thk)
Orientation
(S)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X.
CLTD'
=
=
=
=
=
=
=
=
_
1,378.0
0.0330
77.0
64.0
0.0710
31.0
100.5
0.0710
34.0
415.0
0.0710
44.0
139.0
0.0710
43.0
19.5
0.0710
38.0
132.0
0.0710
52.0
J
Page Total
IItems shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
I Fenestration
OperWdw (10060)(20)
OperWdw (3030)(19)
OperWdw (3030)(18)
OperWdw (4030)(17)
OperWdw (4030)(15)
OperWdw (2620)(16)
OperWdw (6070)(14)
OperWdw (6070)(12)
OperWdw (6070)(13)
Orientation
(E)
(E)
(E)
(E)
(E)
(SE)
(SE)
(Std
(SW)
Btu/hr
3,501
141
243
1,296
424
53
1 6,1461
Shaded
Area GLF
38.0 X 21.7
0.0 X 21.7
0.0 X 21.7
0.0 X 21.7
0.0 X 21.7
0.0 X 21.7
42.0 X 21.7
42.0 X 21.7
42.0 X 21J
Unshaded
Area
+ 22.0
+ 9.0
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
47.6
47.6
+
+
9.0
47.6
12.0
47.6
+
12.0
47.6
+
+
+
5.0
46.9
0.0
46.9
0.0
59.1
+1 0.0
Page Total
Btu/hr
1,873
428
428
571
571
234
913
913
913
Internal Gain Btu/hr
Occupants 2.0 OccupantsX 230 Btuh/occ. _ 460
Equipment 0.0 Dwelling Unit X 1,200 Btu - 0
Infiltration: 1.064 X 1.24 X 75.40 X 40 = 3,982
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,433
Latent Gain Btu/hr
Occupants 2.0 Occupants X 200 Btuh/occ. = 400
Infiltration: 4,771 X 1.24 X 75.40 X 0.00467 = 2,085
Air Sensible CFM ELA AW
[TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 9 dpF
RESIDENTIAL ROOM COOLING LOAD SUMMARY
rrulecr rvarue Date
Evertson Residence 6/29/2011
ROOM INFORMATION DESIGN CONDITIONS
Room Name Grt. Rm / Kit. / Dining Outdoor Dry Bulb Temperature 112 OF
Floor Area 3,926.0 ft' Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 72 OF Outdoor Daily Ranqe: 34 OF
Surfaces
Icynene (Roof) (R-38, 10" Thk)
Icynene (Wall) (R-21, 5.5" -Thk)
Icynene (Wall) (R-21, 5.5" Thk)
Icynene (Wall) (R-21, 5.5" Thk)
Icynene (Wall) (R-21, 5.5" Thk)
Icynene (Wall) (R-21, 5.5" Thk)
Icynene (Wall) (R-21, 5.5" Thk)
Icynene (Wall) (R-21, 5.5" Thk)
I (NE) I
I'm I
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
c
=
c
c
=
=
3,926.0
0.0330
56.0
413.2
0.0710
23.0
150.0
0.0710
29.0
24.0
0.0710
33.0
161.5
0.0710
31.0
346.2
0.0710
26.0
128.9
0.0710
31.0
703.5
0.0710
33.0
X
X
X
20.4
=
18.2
64.0
Paqe Total
IItems shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
FPflAC}fA}1[1rfl
SwngGIsDr (6090)(0)
FxdWdw (2866)(37)
SwngGIsDr (3080)(N)
FxWdw (2060) Abv.(38)
FxWdw (2020) Abv.(39)
FxWdw (2020) Abv.(42)
OperWdw (8080)(43)
FxWdw (5020) Abv. (44)
FxdWdw (1670)(11)
Orientation
(N)
Btu/hr
7,255
675
309
56
355
639
284
1, 648
1 11,2221
Shaded
Area
GLF
Unshaded
Area
+ 54.0 X
+ 17.3 X
+ 24.0 X
+ 12.0 X
+ 4.0 X
GLF
0.0
X
X
14.1
14.1
=
0.0
18.2
18.2
=
0.0
X
X
X
14.1
14.1
c
0.0
20.4
20.4
c
0.0
20.4
20.4
=
0.0 X
0.0 X
0.0 X
10.5 X
20.4
+
+
+
4.0
X
X
X
20.4
=
18.2
64.0
27.5
=
20.4
10.0
Latent Gain
20.4
+1
0.01
X
2.0 Occupants X 200 Btuh/occ.
= 400
Page Total
Btu/hr
759
314
337
244
81
81
1,759
319
214
4,110
Internal Gain
Btu/hr
Occupants
2.0
Occupants X
230
Btuh/occ.
460
Equipment
1.0
Dwelling Unit X
1,600
Btu
-
_
1,600
Infiltration:
)( 1.24 X 214.83
X 40 '=
11,345
Sensible
Air Sensible CFM ELA
AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
42,142
Latent Gain
Btu/hr
Occupants
2.0 Occupants X 200 Btuh/occ.
= 400
Infiltration:
X 1.24 X 214.83
X 0.00467 =
5,940
Sensible
Air Sensible CFM ELA
AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM a '2An
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Evertson Residence 6/29/2011
ROOM INFORMATION DESIGN CONDITIONS
Room Name Grt. Rrri / Kit. / Dining Outdoor Dry Bulb Temperature 112 OF
Floor Area 3,926.0 ft2 Outdoor Wet Bulb Temperature 78 °F
Indoor Dry Bulb Temperature 72 OF Outdoor Dailv Ranae: 34 OF
ue Surfaces Orientation
Area U -Factor CLTD'
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X
X X
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
S/dgG/sDr (90100)(/)
S/dgG/sDr (210100)(J)
FxdWdw (41070)(10)
FxWdw (2020) Abv.(40) .
FxWdw (2020) Abv.(41)
FxdWdw (3370)(9)
OperWdw (4470)(8)
S/dgG/sDr (90100)(H)
SwngG/sDr (2680)(F)
Orientation
(SE)
(S)
(S)
(S)
(S)
(SK9
(S K9
(SIAL
(�
Shaded
Area
GLF
+
+
+
+
+
+
+
+
+
Unshaded
Area
0.0 X
0.0 X
GLF
=
=
=
=
0
0
=
=
=
90.0
X
X
18.7
26.0
210.0
•18.7
18.7
33.8
X
20.4
0.0
X
X
X
X
X
20.4
0.0
X
20.4
4.0
20.4
0,01
X
20.4
4.0
20.4
22.8
X
X
20.4
0.0
28.6
30.3
18.2
0.0
24.8
90.0 X
0.0 X
18.7
0.0 X
20.0 X
26.0
14.1
25.3
Page Total
Btu/hr
01
Btu/hr
1,681
3,922
688
82
82
464
550
1.681
Internal Gain Btu/hr
Occupants 2.0 Occupants X 230 Btuh/occ. = 460
Equipment 1.0 Dwelling Unit X 1,600 Btu c 1,600
Infiltration: 1.064 )( 1.24' X 214.83 X 40 = 11,345
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM NBtu/h
Latent Gain Occupants 2•o Occupants X 20o Btuh/occ.Infiltration: sibleX X X
Air Sensible CFM ELA ptp/
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM a awn
RESIDENTIAL ROOM COOLING LOAD SUMMARY'
Project Name
Date
Evertson Residence
6/29/2011
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Grt. Rm /Kit. /Dining
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,926.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 72 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
X
X
_
-X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
OperWdw (4040)(6)
(W) 0.0 X 18.2 +
'16:0
X 35.4
= 566
OperWdw (6050)(34)
(W) 0.0 X 18.2 +
30.0
X 35.4
c 1,061
OperWdw (6050)(35)
(W) 0.0 X 18.2 +
30.0
X 35.4
= 1,061
OperWdw (6050)(36)
(W) 0.0 X 18.2 +
30.0
X 35.4
= 1,061
X +
X
-
X +
X
-
X +
X
-
X +
X
-
X +
X
-
Page Total
3,750
Internal Gain
Btu/hr
Occupants
2.0 Occupants X 230
Btuh/occ.
460
Equipment
1.0 Dwelling Unit X 1,600
Btu
_
1,600
Infiltration: 1.064
X 1.24 X 214.83 X 40 =
11,345
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
42,142
Latent Gain
Btu/hr
Occupants
2.0 Occupants X 200
Btuh/occ.
=
400
Infiltration:
X 1.24 X 214.83 X 0.00467 =
5,940
Sensible
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT
HEAT GAIN FOR ROOM
6,340
Ener Pro 5.1 by Ene Soft
User Number: 3665 RunCode: 2011-06-29709:40:42 ID:
Page 44 of 47
RESIDENTIAL ROOM COOLING LOAD. SUMMARY
Project Name
Date
Evertson .Residence
6/29/2011
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Guest Bed 4
Outdoor Dry Bulb Temperature
112 OF
Floor Area
512.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 72.°F
I Outdoor Daily' Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor -
CLTD'
Btu/hr. .
Icynene (Roof) (R-38, 10" Thk)
512.0 X 0.0330
X 77.0 =
1,301
Icynene (Wall) (R-21, 5.5" Thk)
(StM 66.0 X 0.0710
X 52.0 =
244
Icynene (Wall) (R-21, 5.5" Thk)
(149 192.5 X 0.0710
X 55.0 =
752
Icynene (Wall) (R-21, 5.5" Thk)
(NtA9 82.5 X 0.0710
X - 48.1 =
282
X
X' _
X
X =
X
X =
X
X =
X
X =
Page Total
2,578
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area GLF
Btu/hr
OperWdw (6050)(2)
(K9 0.0 X 21.7 +
30.0 X 64.8
= 1,944
FxWdw (2020) Abv. (3)
W 0.0 X 24.8 +
4.0 X 78.2
= 313
FxWdw (2020) Abv. (4)
(W) .0.0 X 24.8 +
4.0 X 78.2
= 313
FxWdw (2020) Abv.(5)
(tM 0.0 X 24.8 +
4.0 X 78.2
= 313
SwngGIsDr(3080)(E)
(W) 0.0 X 16.4 +
24.0 X 44.6
= 1,070
OperWdw (5030)(1)
0.0 X 21.7 +
15.0 X 64.8
= 972
X +
X
-
X +
X
-
X +1
X
-
Page Total
4,925
Internal Gain
Btu/hr
Occupants
1.0 Occupants X 230
Btuh/occ. =
230
Equipment
0.0 Dwelling Unit X 1,200
Btu =
0
Infiltration: 1.064
X 1.24 X 28.02 X 40 =
1,479
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
9,213
Latent Gain
Btu/hr
Occupants
1.0 Occupants X 200
Btuh/occ. =
200
Infiltration: 4,771
X 1.24 X 28.02 X 0.00467 =
775
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
975
Ener Pro 5.1 by Ener Soft
User Number: 3665 RunCode: 2011-06-29709:40:42 ID:
Page 45 of 47
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Evertson Residence
6/29/2011.
ROOM INFORMATION
DESIGN CONDITIONS
Room. Name Casita / Guest Bed 5
Outdoor Dry Bulb Temperature
112 OF
Floor Area 534.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 72 OF
Outdoor Daily Range:
34 OF,
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
Icynene (Roof) (R-38, 10" Thk) (149 534.0 X 0.0330
X 56.0 - =
987
Icynene (Wall) (R-21, 5.5" Thk) (NE) 127.5 X 0.0710
X 29.0 =
263
Icynene (Wall) (R-21, 5.5" Thk) (SE) 228.5 X 0.0710
X 31.0 =
503
Icynene (Wall) (R-21, 5.5" Thk) (St9 210.0 X 0.0710
X 31.0 =
462
Icynene (Wall) (R-21, 5.5" Thk) (149 43.5 X 0.0710
X 33.0 =
102
Icynene (Wall) (R-21, 5.5" Thk) (NlM 34.5 •X 0.0710
X 30.2 c
74
Wood Door (Vq (NKq 24.0 X 0.5000
X 30.2 =
363
Icynene (Floor) (R-38, 10" Thk) 534.0 X 0.6290
X 19.0 c
294
X
X =
Items shown with an•asterisk (') denote conduction through an interior surface to another room.
Page Total
3,047
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area GLF .
Btu/hr
SwngGlsDr (6080)(149 (NE) 0.0 X 14.1 +
48.0 X 20.2
c 968
OperWdw (2020)(55) (SE) 0.0 X 18.2 +
4.0 X 24.8
= 99
OperWdw (3020)(54) (SE) 0.0 X 18.2 +
6.0 X 24.8
c 149
OperWdw (3020)(53) (SK9 0.0 X 18.2 +
6.0 X 24.8
c 149
OperWdw (3020)(52) W 0.0 X 18.2 +
6.0 X 35.4
c 212
X +
X
_
X +
X
-
X +
X
_
X +
X
-
Page Total
1,577
Internal Gain
Btu/hr
Occupants 1.0 Occupants X 230
Btuh/occ. =
230
Equipment 0.0 Dwelling Unit X 1,600
Btu =
0
Infiltration: 1.064 X 1.24 X 29.22 X 40 =
1,543
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
6,398
Latent Gain
Occupants 1.0 Occupants X 200
Btuh/occ.
Btu/hr
=
200
Infiltration: 4,771 X 1.24 X 29.22 X 0.00467 =
808
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,008
Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID:
Page 46 of 47
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Evertson Residence
6/29/2011
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Casita 7 Guest Bed '6
Outdoor Dry Bulb Temperature
112 OF
Floor Area
521.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 72 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
Icynene (Root) (R-38, 10" Thk)
(149 521.0 X 0.0330
X, 56.0 =
963
Icynene (Wall) (R-21, 5.5" Thk)
(N) 175.0 X 0.0710
X 23.0 =
286
Icynene (Wall) (R-21, 5.5" Thk)
(E) 223.0 X 0.0710
X 33.0 =
522
Icynene (Wall) (R-21,•5.5" Thk)
(SE) 30.0 X 0.0710
X 31.0 =
66
Icynene (Wall) (R41, 5.5" Thk)
(S) 151.5 X 0.0710
X 26.01
280
.Wood Door (S)
(S) 24.0 X 0.511 000
X 26.0 =
312
Icynene (Wall) (R-21, 5.5" Thk)
(VV) 281.5 X 0.0710
X 33.0 =
660
Icynene (Floor) (R-38, 10" Thk)
521.0 X 0.0290
X 19.0 =
287
X J
X =
Page Total
3,375
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area GLF
Btu/hr
OperWdw (3020)(47)
(N) 0.0 X 18.2 +
6.0 X 18.2
= 109
OperWdw (4020)(46)
(N) 0.0 X 98.2 + -
8.0 X 18.2
= 145
OperWdw (4020)(56)
(E) 0.0 X 18.2 +
8.0 X 35.4
= 283
SwngG/sDr (6080)(7)
(E) 27.6 X 14.1+
20.4 X 25.3
= 905
OperWdw (2020)(51)
(►M 0.0 X 18.2 +
4.0 X 35.4
= 142
OperWdw (2020)(50)
(169 0.0 X 18.2 +
4.0 X 35.4
= 142
OperWdw (2020)(49)
0.0 X 18.2 +
4.0 X 35.4
= 142
OperWdw (4020)(48)
0.0 X 18.2 +
8.0 X 35.4
= 283
X 1 +1
X
=
Page Total
2,149
Internal Gain
Btu/hr
Occupants
1.0 Occupants X 230
Btuh/occ. =
230
Equipment
0.0 Dwelling Unit X 1,600
Btu =
0
Infiltration: 1.064
X 1.24 X 28.51 X 40 =
1,505
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
7,260
Latent Gain
Btu/hr
Occupants
1.0 Occupants X 200
Btuh/occ. =
200
Infiltration: 4,771
X 1.24 X 28.51 X 0.00467 =
788
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
988
Ener Pro 5.1 by Ener Soft
User Number: 3665 RunCode: 2011-06-29709:40:42 ID:
Page 47 of 47
r Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011
1 Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Evertson Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
Project Address
53-165 Humboldt Boulevard La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
8,354
Addition
n/a
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
Roof Wood Framed Rafter Filled 8,354 New
Wall Wood Framed Filled 5,701 New
Slab Unheated Slab -on -Grade None 8,592 Perim = 547' New
Door Opaque Door None 24 New
Floor Wood Framed w/o Crawl Space R-38 1,055 New
Door Opaque Door None 24 New
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC , Overhang Sidefins Shades Status
Front (N) 15.0 0.370 _
0.29 none none Bug Screen New
Left (E) 15.0 0,370 e _ Bug Screen New
Left (E) 15.0 0 370 C 0. no Bug Screen New
Left (E) 42.0 0. 70RJ III DING
ne Bug Screen � New
Left (E) 42.0 0. 70 fun
an OV P De Bug Screen New
Left (E) 4.0 0. 50 flh
none Screen New
tJe:FBug
Left(E) 4.0 0. 50 F 6CQ none Bug. Screen New
Left (E) 4.0 0.
Bug Screen New
Left (E) 15.0 0.3
Left (E) 44.0 0.5 &040,364one
BY Bug Screen New
none Bug Screen New
Left (E) 4.0 0.350
0.36 none none Bug Screen New
HVAC SYSTEMS
Ot . HeatingMin. Eff
t_ (pit
Cooling"Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 16.2 SEER Setback
New
1 Central Furnace 80% AFUE
Split Air Conditioner 16.2 SEER Setback
New
3 Central Furnace 80% AFUE
Split Air Conditioner 16.2 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
to Duct
Cooling _Duct Location R -Value Status
Zone #1 Ducted
Ducted Conditioned 6.0 New
Zone #2 Ducted
Ducted Conditioned 6.0 New
Zone #3 Ducted
Ducted Conditioned 6.0 New
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
2 Large Gas 100
0.80 Kitchen Pipe Ins New
Energ Pro 5.1 by Ener Soft User Number: 3665
Run Code: 2011-06-29T09:40:42 ID:
Pae 1 of 15
Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc
Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011
Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2013
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Evertson Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
Project Address
53-165 Humboldt Boulevard
La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
8,354
Addition
n/a
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
FENESTRATION
Orientation Area(fe)
U- Exterior
Factor SHGC Overhang Sidefins Shades Status
Left (E) 4.0
0.350 0.36 none none Bug Screen New
Left (E) 4.0
0.350 0.36. none - none Bug Screen New
Left (E) 60.0
0.370 0.29 6.0 none Bug Screen New
Left (E) 9.0
0.370 0.29 norie none Bug Screen New
Left (E) 9.0
0.370 0.29 none none Bug Screen New
Left (E) 12.0
0.370 ' 0.29 none none Bug Screen New
Left (E) 12.0
0.370 0.29 none none Bug Screen New
Left (SE) 5.0
0.370 0.29 none none Bug Screen New
Left (SE) 42.0
0.370 0.29 8.0 none Bug Screen New
Rear (SM 42.0
0.370 0.29 18.0 none Bug Screen New
Rear (SVV) 42.0
0.370 0.29 18.0 none Bug Screen New
HVAC SYSTEMS
Ot . Heating
Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace
80% AFUE Split Air Conditioner 20.7 SEER Setback
New
1 Central Furnace
80% AFUE Split Air Conditioner 20.7 SEER Setback
New
1 Central Furnace
80% AFUE Split Air Conditioner 20.7 SEER Setback
New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
Zone #4 Ducted
Ducted Conditioned 6.0
New
Zone #5 Ducted
Ducted Conditioned 6.0
New
Zone #6 Ducted
Ducted Conditioned 6.0
New
WATER HEATING
Ot . Type
Gallons Min. Eff Distribution Status
Energ Pro 5.1 by Ener Soft User Number: 3665 Run Code: 2011-06-29T09:40:42 /D:
Page 2 of 15
Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: Ca10ERTS, Inc
Electronically Filed by Scott DeVoe and Authenticated at Ca10ERTS.com - 6/29/2011
Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Evertson Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
Project Address
53-165 Humboldt Boulevard La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. FloorArea
8,354
Addition
Tn/a
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
CavityFeatures see Part 2 of 5 Status
FENESTRATION U-
Orientation Area(fo Factor
Exterior
SHGC Overhang Sidefins Shades Status
Front (N) 54.0 0.350
0.19 22.0 none Bug Screen New
Front (N) 17.3 0.370
0.29 none none Bug Screen New
Front (N) 24.0 0.350
0.19 18.0 none Bug Screen New
Front (N) '12.0 0.350
0.36 none none Bug Screen New
Front (N) 4.0 0.350
0.`36 none none Bug Screen New
Front (N) 4.0 0.350
0.36 none none Bug Screen New
Front (NE) 64.0 0.370
0.29 5.0 none Bug Screen New
Front (NE) 10.0 0.350
0.36 none none Bug Screen New
Left (SE) 10.5 0.350
0.36 30.0 none Bug Screen New
Left (SE) 90.0 0.340
0.32 30.0 none Bug Screen New
Rear (S) 210.0 0.340
0.32 30.0 none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
Energ Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID:
Page 3 of 15
Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: Ca10ERTS, Inc
Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011
Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2013
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Evertson Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
Project Address
53-165 Humboldt Boulevard La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
8,354
Addition
n/a
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
FENESTRATION U-
Orientation Area(fiz) Factor
Exterior
SHGC Overhang Sidefins Shades Status
Rear (S) 33.8 0.350
0.36 30.0 none 'Bug Screen New
Rear (S) 4.0 0.350
0.36 - none none Bug Screen New
Rear (S) 4.0 0.350
0.36 none none Bug Screen New
Rear (SW) 22.8 0.350
0.36 30.0 f none Bug Screen New
Rear (SM 30.3 0.370
0.29 30.0 none Bug Screen New
Rear (SM 90.0 0.340
0.32 30.0 none Bug Screen New
Right (W) 20.0 0.350
0.19 none none Bug Screen New
Right (W) 16.0 0.370
0.29 none none Bug Screen New
Right (W) 30.0 0.370
0.29 none none Bug Screen New
Right ((M 30.0 0.370
0.29 none none Bug Screen New
Right (tM 30.0 0.370
0.29 none none Bug Screen New
HVAC SYSTEMS
(fit . Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by Ener Soft User Number: 3665 Run Code: 2011-06-29T09:40:42 ID:
Pa e 4 of 15
Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc
Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011
Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Evertson Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
Project Address
53-165 Humboldt Boulevard La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
8,354
Addition
n/a
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
CavityFeatures see Part 2 of 5 Status
FENESTRATION U-
Orientation Area(ft) Factor
Exterior
SHGC Overhang Sidefins Shades Status
Right (tom 30.0 0.370
0.29 none none Bug Screen New
Right 4.0 0.350
0.36 none none Bug Screen New
Right (tM 4.0 0.350
0.36 none none Bug Screen New
Right (149 4.0 0.350
0.36 none none Bug Screen New
Right (VV) 24.0 0.350
0.19 none none Bug Screen New
Right (lM 15.0 0.370
0.29 none none Bug Screen New
Front (NE) 48.0 0.350
0.19 9.0 none Bug Screen New
Leff (SE) 4.0 0.370
0.29 none none Bug Screen New
Left (SE) 6.0 0.370
0.29 none none Bug Screen New
Rear (Sly 6.0 0.370
0.29 none none Bug Screen New
Right (M 6.0 0.370
0.29 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29709:40:42 ID:
Page 5 of 15
Reg: 211-NO031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc
Electronically Filed by Scott DeVoe and Authenticated at Ca10ERTS.com - 6/29/2011
Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2013
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Evertson Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
Project Address
53-165 Humboldt Boulevard La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
8,354
Addition
Fn/a
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Front (N) 6.0 0.370 0.29 none none Bug Screen New
Front (N) 8.0 0.370 0.29- none none Bug Screen New
Left (E) 8.0 0.370 0.29 none none Bug Screen New
Left (E) 48.0 0.350 0.19 7.0 none Bug Screen New
Right (tM 4.0 0.370 0.29 none none Bug Screen New
Right (W) 4.0 0.370 0.29 none none Bug Screen New
Right (W) 4.0 0.370 0.29 none none Bug Screen New
Right (W) 8.0 0.370 0.29 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
WATER HEATING
Qty. Type Gallons Min. 'Eff Distribution Status
Ener Pro 5.1 by Ener Soft User Number: 3665 Run Code: 2011-06-29T09:40:42 /D:
Page 6 of 15
Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc
Electronically Filed by Scott Devoe and Authenticated at CalCERTS.com - 6/29/2011
Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Eveftson Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special 'ustification and documentation submitted.
The DHW System Bradford White 100 Gal is a non-NAECA large storage gas water heater. Verity DHW details.
The HVAC System Zone #1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
The HVAC System Zone #4 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
The HVAC System Zone #5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
The HVAC System Zone #6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a
se arate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
i
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System Zone #1 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually
verify the installation of the HVAC unit and all Ducts and Plenums.
The HVAC System Zone #1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System Zone #2 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually
verify the installation of the HVAC unit and all Ducts and Plenums.
The HVAC System Zone #2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System Zone #3 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually
verify the installation of the HVAC unit and all Ducts and Plenums.
The HVAC System Zone #3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System Zone #4 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually
verify the installation of the HVAC unit and all Ducts and Plenums.
The HVAC System Zone #4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
Ener Pro 5.1 by Ener Soft User Number: 3665 Run Code: 201 1-06-29 70 9:40:42 ID: Pa - e 7 of 15
Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc
Electronically Filed by Scott Devoe and Authenticated at Ca10ERTS.com - 6/29/2011
Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Evertson Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
t
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System Zone #5 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually
verify the installation of the HVAC unit and all Ducts and Plenums.
The HVAC System Zone #5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System Zone #6 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually
verify the installation of the HVAC unit and all Ducts and Plenums.
The HVAC System Zone #6 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
Ener Pro 5.1 by Ener Soft User Number: 3665 Run Code: 2011-06-29709:40:42 /D: Page 8 of 15
Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc
Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011
Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Evertson Residence
❑ Multi Family ❑ Existing+ Addition/Alteration
6/29/2011
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 3.70 2.85 0.85
Space Cooling 61.41 57.74 3.68
Fans 12.08 13.43 -1.35
Domestic Hot Water 4.11 2.74 1.37
Pumps 0.00 0.00 0.00
Totals 81.31 76.76 4.55
Percent Better Than Standard: 5.6%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (N) 1,610 266
Fuel Available at Site: Natural Gas (E) 2,264 513
Raised Floor Area: 1,055 (S) 1,591 485
Slab on Grade Area: 6,592 (Vto 1,783 233
Average Ceiling Height: 12.0 Roof 8,354 0
Fenestration Average U -Factor: 0.36 TOTAL: 1,497
Average SHGC: 0.30 Fenestration/CFA Ratio: 17.9%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company BREEZE AIR CONDITIONING
Address Name Scott DeVoe 6/29/2011
75-145 St. Charles Place
City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone (760) 346-0855 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Andrzej W. Weber Architect
Address 2276 Via Alba Name Andrzej W. Weber
City/State/Zip Palm Desert, CA 92260 Phone (760) 340-3002 Signed License # Date
Ener Pro 5.1 by Ener Soft User Number: 3665 Run Code: 2011-06-29709:40:42 ID: Page 9 of 15
Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc
Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011
Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2012
CERTIFICATE OF COMPLIANCE:
Residential
(Part 4 of 5) CF -1 R
Project Name
Evertson Residence
Building Type ® Single Family O Addition Alone
O Multi Family O Existing+ Addition/Alteration
Date
1612912011
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation
Factor Cavit Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Roof
1,483
0.033 Filled
270
0 New 4.2.2-A23
Zone #1
Wall
313
0.071 Filled
0
90 New 4.3.1-A 15
Zone #1
Wall
530
0.071 Filled
90
90 New 4.3.1-A15
Zone #1
Wall
28
0.071 Filled
180
90 New 4.3.1-A15
Zone #1
Wall
188
0.071 Filled
270
90 New 4.3.1-A15
Zone #1
Slab
1,483
0.730 None
0
180 New 4.4.7-A1
Zone #1
Roof
1,378
0.033 Filled
270
0 New 4.2.2-A23
Zone #2
Wall
64
0.071 Filled
0
90 New 4.3.1-A 15
Zone #2
Wall
101
0.071 Filled
45
90 New 4.3.1-A 15
Zone #2
Wall
415
0.071 Filled
90
90 New 4.3.1-A 15
Zone #2
Wall
139
0.071 Filled
1351
90 New 4.3.1-A15
Zone #2
Wall
20
0.071 Filled
180
90 New 4.3.1-A15
Zone #2
Wall
132
0.071 Filled
225
90 New 4.3.1-A 15
Zone#2
Slab
1,557
0.730 None
0
180 New 4.4.7-A1
Zone #2
Roof
3,926
0.033 Filled
270
0 New 4.2.2-A23
Zone #3
Wall
413
0.071 Filled
0
90 New 4.3.1-A15
lZone #3
FENESTRATION SURFACE DETAIL'S
ID
Type
Area U -Factor
SHGC2
Azm Status
Glazing Type
Location/Comments
1
Window
15.0 0.370 NFRC
0.29 NFRC
0 New
Wood Clad LoIE (Oper)(33)
Zone #1
2
Window
15.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad LoIE (Oper)(32)
Zone #1
3
Window
15.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad LoIE (O er)(31)
Zone #1
4
Window
42.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad LoIE (Oper)(27)
Zone #1
5
Window
42.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad Lo/E (Oper)(26)
Zone #1
6
Window
4.0 0.350 NFRC
0.36 NFRC
90 New
Wood Clad LoIE (Fix)(28) Abv.
Zone #1
7
Window
4.0 0.350 NFRC
0.36 NFRC
90 New
Wood Clad Lo/E (Fix)(29) Abv.
Zone #1
8
Window
4.0 0.350 NFRC
0.36 NFRC
90 New
Wood Clad Lo/E (Fix)(30) Abv.
Zone #1
9
Window
15.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad LoIE (Oper)(22)
Zone #1
10
Window
44.0 0.570 Default
0.67 Default
90 New
Default Glass Block (21)
Zone #1
11
Window
4.0 0.350 NFRC
0.36 NFRC
90 New
Wood Clad LoIE (Fix)(23) Abv.
Zone #1
12
Window
4.0 0.350 NFRC
0.36 NFRC
90 New
I Wood Clad Lo/E (Fix)(24) Abv.
Zone #1
13
Window
4.0 0.350 NFRC
0.36 NFRC
90 New
Wood Clad LoIE (Fix)(25) Abv.
Zone #1
14
Window
60.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad Lo/E (Oper)(20)
Zone #2
15
Window
9.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad Lo/E (Oper)(19)
Zone #2
16
Window
9.0 0.370 NFRC
0.29 NFRC
90 New
Wood Clad Lo/E (Oper)(18)
Zone #2
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
Hat 7 Wd
Ove hanq Left Fin Ri ht Fin
Len Hcjt LExt RExt Dist I Len H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
7.0 6.0
5.0 1.0
5.0 5.0
5
Bug Screen
0.76
7.0 6.0
5.0 1.0
5.0 5.0
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Buq Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
6.0 10.0
6.0 1.0
6.0 6.0
15
Bug Screen
0.76
16
Bug Screen
0.76
Ener Pro 5.1 by Ener Soft User Number: 3665 RunCode: 2011-06-29T09:40:42 ID:
Pae 10 of 15
Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc
Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011
Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Evertson Residence
Building Type 0 Single Family 0 Addition Alone
0 Multi Family 0 Existing+ Addition/Alteration
Date
1612912011
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation
FactorCavity Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Wall
150
0.071 Filled
45
90 New 4.3.1-A15
Zone #3
Wall
24
0.071 Filled
90
90 New 4.3.1-A 15
Zone #3
Wall
162
0.071 Filled
135
90 New 4.3.1-A15
Zone #3
Wall
1 346
0.071 Filled
180
90 New 14.3.1-A15
Zone #3
Wall
129
0.071 Filled
225
90 New 14.3.1-A 15
Zone #3
Wall
704
0.071 Filled
270
90 New 4.3.1-A 15
Zone #3
Slab
3,926
0.730 None
0
180 New 4.4.7-A1
Zone #3
Roof
512
0.033 Filled
270
0 New 4.2.2-A23
Zone #4
Wall
66
0.071 Filled
225
90 New 4.3.1-A15
Zone #4
Wall
193
0.071 Filled
270
90 New 4.3.1-A15
Zone #4
83
0.071 Filled
315
90 New 4.3.1-A15
Zone #4
Slab
1,626
0.730 None
0
180 New 4.4.7-A1
Zone #4
,Wall
Roof
534
0.033 Filled
270
0 New 4.2.2-A23
Zone #5
Wall
128
0.071 Filled
45
90 New 4.3.1-A15
Zone #5
Wall
229
0.071 Filled
135
90 New 4.3.1-A15
JZone #5
Wall
2101
0.071 Filled
2-5.710
New 4.3.1-A15
lZone #5
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm Status Glazing Type
Location/Comments
17
Window
12.0 0. 3701 NFRC
0.29 NFRC 90 New
Wood Clad Lo/E (Oper)(17)
Zone #2
18
Window
12.0 0.370 NFRC
0.29 NFRC 90 New
Wood Clad Lo/E (Oper)(15)
Zone #2
19
Window
5.0 0.370 NFRC
0.29 NFRC 135 New
Wood Clad Lo/E (Oper)(16)
Zone #2
20
Window
42.0 0.370 NFRC
0.29 NFRC 135 New
Wood Clad Lo/E (Oper)(14)
Zone W2-
21
Window 1
42.0 0.370 NFRC
0.29 NFRC 225 New
Wood Clad Lo/E (Oper)(12)
Zone #2
22
Window
42.0 0.370 NFRC -
0.29 NFRC 225 New
Wood Clad Lo/E (Oper)(13)
Zone #2
23
Window
54.0 0.350 NFRC
0.19 NFRC 0 New
Wood Clad Fr. Door (0) ,
Zone #3
24
Window
17.3 0.370 NFRC
0.29 NFRC 0 New
Wood Clad Lo/E (Oper)(37)
Zone #3
25
Window
24.0 0.350 NFRC
0.19 NFRC 0 New
Wood Clad Fr. Door (N)
Zone #3
26
Window
12.0 0.350 NFRC
0.36 NFRC 0 New
Wood Clad Lo/E (Fix)(38) Abv.-
Zone #3
27
Window
4.0 0.350 NFRC
0.36 NFRC 0 New
Wood Clad Lo/E (Fix)(39) Abv. + Zone #3
28
Window
4.0 0.350 NFRC
0.36 NFRC 0 New
Wood Clad Lo/E (Fix)(42) Abv.
Zone #3
29
Window
64.0 0.370 NFRC
0.29 NFRC 45 New
Wood Clad Lo/E (Oper)(43)
Zone #3
30
Window
10.0 0.350 NFRC
0.36 NFRC 45 New
Wood Clad Lo/E (Fix)(44) Abv.
Zone #3
31
Window
10.5 0.350 NFRC
0.36 NFRC 135 New
Wood Clad Lo/E (Fix)(11)
Zone #3
32
Window
90.0 0.340 NFRC
I 0.32 NFRC 135 New
Wood Clad Lo/E (SGD)(1)
Zone #3
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t I Wd
Ove hanq Left Fin Ri ht Fin
Len H t LExt REA Dist I Len H t Dist Len H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
7.0 6.0 8.0 1.0
8.0 8.0
21
Bug Screen
0.76
7.0 6.0 18.0 1.0
18.0 18.0
22
Bug Screen
0.76
7.0 6.0 18.0 1.0
18.0 18.0
23
Bug Screen
0.76
9.0 6.0 22.0 1.0
22.0 22.0
24
Bug Screen
0.76
25
Bug Screen
0.76
8.0 3.0 18.0 1.0
18.0 18.0
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
7.0 6.0 5.0 1.0
5.0 5.0
30
Bug Screen
0.76
31
Bug Screen
0.76
7.0 1.5 30.0 12.0
30.0 30.0
32
18ug Screen
0.76
10.0 9.0 30.0 12.0
30.0 30.0
Ener
Pro 5.1 by Ener Sok User Number: 3665
Run Code: 2011-06-29T09:40:42 ID:
Pae 11 of 15
Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc
Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011
Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Evertson Residence
Building Type m Single Family ❑ Addition Alone
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1612912011
OPAQUE SURFACE DETAILS
1
Surface
Type Area
U- Insulation
Factor Cavit Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Wall
44
0.071 Filled
270
90 New 4.3.1-A15
Zone #5
Wall
35
0.071 Filled
315
90 New 4.3.1-A15
Zone #5
Door
24
0.500 None
315
90 New 4.5.1-A4
Zone #5
Floor
534
0.029 R-38
0
180 New 4.4.2-A8
Zone #5
Roof
521
0.033 Filled
270
0 New 4.2.2-A23
Zone #6
Wall
175
0.071 Filled
0
90 New 4.3.1-A 15
Zone #6
Wall
223
0.071 Filled
90
90 New 4.3.1-A15
Zone #6
Wall
30
0.071 Filled
135
90 New 4.3.1-A 15
Zone #6
Wall
152
0.071 Filled
180
90 New 4.3.1-A15
Zone #6
Door
24
0.500 None
180
90 New 4.5.1-A4
Zone #6
Wall
282
0.071 Filled
270
90 New 4.3.1-A15
Zone #6
Floor
521
0.029 R-38
0
180 New 4.4.2-A8
Zone #6
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm Status Glazing Type
Location/Comments
33
Window
210.0 0.340 NFRC
0.32 NFRC 180 New
Wood Clad Lo/E (SGD)(J)
Zone #3
34
Window
33.8 0.350 NFRC
0.36 NFRC 180 New
Wood Clad Lo/E (Fix)(10)
Zone #3
35
Window
4.0 0.350 NFRC
0.36 NFRC 180 New
Wood Clad Lo/E (Fix)(40) Abv.
Zone #3
36
Window
4.0 0.350 NFRC
0.36 NFRC 180 New
Wood Clad Lo/E (Fix)(41) Abv.
Zone #3
37
Window
22.8 0.350 NFRC
0.36 NFRC 225 New
1 Wood Clad Lo/E (Fix)(9)
Zone #3
38
Window
30.3 0.370 NFRC
0.29 NFRC 225 New
Wood Clad Lo/E (Oper)(8)
Zone #3
39
Window
90.0 0.340 NFRC
0.32 NFRC 225 New
Wood Clad Lo/E (SGD)(H)
Zone #3
40
Window
20.0 0.350 NFRC
0.19 NFRC 270 New
Wood Clad Fr. Door (F)
Zone #3
41
Window
16.0 0.370 NFRC
0.29 NFRC 270 New
Wood Clad Lo/E (Oper)(6)
Zone #3
42
Window
30.0 0.370 NFRC
0.29 NFRC 270 New
Wood Clad Lo/E (Oper)(34)
Zone #3
43
Window
30.0 0.370 NFRC
0.29 NFRC 270 New
Wood Clad Lo/E (Oper)(35)
Zone #3
44
Window
30.0 0.370 NFRC
0.29 NFRC 270 New
Wood Clad Lo/E (Oper)(36)
Zone #3
45
Window
30.01 0.370 NFRC
0.29 NFRC 270 New
Wood Clad Lo/E (Oper)(2)
Zone #4
46
Window
4.0 0.350 NFRC
0.36 NFRC 270 New
Wood Clad Lo/E (Fix)(3) Abv.
Zone #4
47
Window
4.0 0.350 NFRC
0.36 NFRC 270 New
Wood Clad Lo/E (Fix)(4) Abv.
Zone #4
48
Window
4.0 0.350 NFRC
0.36 NFRC 270 New
Wood Clad Lo/E (Fix)(5) Abv.
I Zone #4
(1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t I Wd
Ove hanq Left Fin Ri ht Fin
Len I H t LExt I RExt Dist I Len H t Dist Len Hat
33
Bug Screen
0.76
10.0 21.0 30.01 12.0
30.01 30.0
34
Bug Screen
0.76
7.0 4.8 30.01 12.0
30.01 30.0
35
Bug Screen
0.76
36
Bug Screen
0.76
37
Bug Screen
0.76
7.0 3.3 30.0 12.0
30.0 30.0
38
Bug Screen
0.76
7.01 4.3 30.0 12.0
30.0 30.0
39
Bug Screen
0.76
10.01 9.0 30.0 12.0
30.0 30.0
40
Bug Screen
0.76
41
Bug Screen
0.76
42
Bug Screen
0.76
43
Bug Screen
0.76
44
Bug Screen
0.76
45
Bug Screen
0.76
1E
46
Bug Screen
0.76
47
JBug Screen
0.76
48
JBug Screen
0.76
Ener
Pro 5.1 by Ener Soft User Number: 3665
RunCode: 2011-06-29T09:40:42 ID:
Pae 12 of 15
Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc
Electronically Filed by Scott DeVoe and Authenticated at CalCERTS.com - 6/29/2011
Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2013
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Evertson Residence
Building Type 0 Single Family 0 Addition Alone
0 Multi Family 0 Existing+ Addition/Alteration
Date
6/29/2011
OPAQUE SURFACE DETAILS
Surface U-
-Type Area Factor
Insulation Joint Appendix
Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
U -Factor
SHGC
Azm Status Glazing Type
Location/Comments
49
Window 24.0
0.350 1 NFRC
0.19 NFRC 270 New Wood Clad Fr. Door (E)
Zone #4
50
Window 15.0
0.370 NFRC
0.29 NFRC 270 New Wood Clad Lo/E (Oper)(1)
Zone #4
51
Window 48.0
0.350 NFRC
0.19 NFRC 45 New Wood Clad Fr. Door (W)
Zone #5
52
Window 4.0
0.370 NFRC
0.29 NFRC 135 New Wood Clad Lo/E (Oper)(55)
Zone #5
53
Window 1 6.0
0.370 NFRC
0.29 NFRC 135 New Wood Clad Lo/E (Oper)(54)
Zone #5
54
Window 6.0
0.370 NFRC
0.29 NFRC 225 New Wood Clad Lo/E (Oper)(53)
Zone #5
55
Window 6.0
0.370 NFRC
0.29 NFRC 270 New Wood Clad Lo/E (Oper)(52)
Zone #5
56
Window 6.0
0.370 NFRC
0.29 NFRC 0 New Wood Clad Lo/E (Oper)(47)
Zone #6
57
Window 8.0
0.370 NFRC
0.29 NFRC 0 New Wood Clad Lo/E (Oper)(46)
Zone #6
58
Window 8.0
0.370 NFRC
0.29 NFRC 90 New Wood Clad Lo/E (Oper)(56)
Zone #6
59
Window 48.0
0.350 NFRC
0.19 NFRC 90 New Wood Clad Fr. Door (T)
Zone #6
60
Window 4.0
0.370 NFRC
0.29 NFRC 270 New Wood Clad Lo/E (Oper)(51)
Zone #6
61
Window 4.0
0.370 NFRC
0.29 NFRC 270 New Wood Clad Lo/E (Oper)(50)
Zone #6
62
Window 4.0
0.370 NFRC
0.29 NFRC 270 New Wood Clad Lo/E (Oper)(49)
Zone #6
63
Window 8.0
0.370 NFRC
0.29 NFRC 270 New Wood Clad Lo/E (Oper)(48)
Zone #6
(1) LI -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade T
e SHGC
Window
H t Wd
Ove hanq Left Fin
Len H t LExt RExt Dist Len I
Ri ht Fin
H t Dist Len H t
49
Bug Screen
0.76
50
Bug Screen
0.76
51
Bug Screen
0.76
8.0 6.0 9.0 1.0 9.0 9.0
52
Bug Screen
0.76
53
Bug Screen
0.76
54
Bug Screen
0.76
55
Bug Screen
0.76
56
Bug Screen
0.76
57
Btkq Screen
0.76
58
Bug Screen
0.76
59
Bug Screen
0.76
8.0 6.0 7.0 1.0 7.0 7.0
60
Bug Screen
0.76
61
Bug Screen
0.76
62
Bug Screen
0.76
63
Bug Screen
0.76
Ener
Pro 5.1 by Ener Soft
User Number: 3665
RunCode: 2011-06-29709:40:42 ID:
Pae 13 of 15
Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc
Electronically Filed by Scott Devoe and Authenticated at CaICERTS.com - 6/29/2011
Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011
CERTIFICATE OF COMPLIANCE: Residential
(Part 5 of 5)
CF -1 R
Project Name
Evertson Residence
Building Type la Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ft
New Existinq Altered Removed Volume
Year Built
Zone #1 Mst. Bedroom
1,483
16,313
Zone #2 Office / Guest Bed 2 & 3
1,378
14,469
Zone #3 Grt. Rm / Kit. / Dining
3,926
54,964
Zone #4 Guest Bed 4
512
5,120
Zone #5 Casita / Guest Bed 5
534
4,806
Zone #6 Casita / Guest Bed 6
521
4,689
Totals 8,354 0
+0— 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Type
Min. Eff. Thermostat Type
Status
Zone #1 1 Central Furnace
--Cooling
80% AFUE Split Air Conditioner
16.2 SEER Setback
New
Zone #2 1 Central Furnace
80% AFUE Split Air Conditioner
16.2 SEER Setback
New
Zone #3 3 Central Furnace
80% AFUE Split Air,, Conditioner
.16.2 SEER Setback
New
Zone #4 1 Central Furnace
80% AFUE Split i41r Conditioner
120.7 SEER Setback
New
Zone #5 1 Central Furnace
80% AFUE Split Air Conditioner
1 r20.7 SEER Setback
New
HVAC DISTRIBUTION
System Name Heating
.:, ,aDuct.r '" V
Coolin Duct Location R -Value
Ducts' `
Tested? Status
Zone #1 Ducted Ducted Conditioned
6.0
m
New
Zone #2 Ducted Ducted Conditioned
6.0
m
New
Zone #3 Ducted Ducted Conditioned
6.0
New
Zone #4 Ducted Ducted I Conditioned
6.01
New
Zone #5 Ducted Ducted Conditioned
601
INew
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Bradford White 100 Gal
2
Large Gas
Kitchen Pipe Ins
85,000
100
0.80
0.00%
0.0
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water
Piping Length
ft
�
0
m
CQ
System Name
Pipe
Pipe
Diameter
Insul.
Thick.
Qt . HP
Plenum Outside Buried
O
_Length
Ener Pro 5.1 by Ener Soft User Number: 3665
RunCode: 2011-06-29T09:40:42 ID:
Pae 14 of 15
Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc
Electronically Filed by Scott Devoe and Authenticated at CalCERTS.com - 6/29/2011
Electronically Signed at CalCERTS.com by Kelly Bradshaw (Bradshaw Construction Inc) 7/15/2011
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R
Project Name
Evertson Residence
Building Type 10 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
6/29/2011
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existinq Altered Removed Volume Year Built
Totals 8,3541 01 01 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff, Thermostat Type Status
Zone #6 1 Central Furnace
80% AFUE Split Air Conditioner 20.7 SEER Setback New
HVAC DISTRIBUTION
System Name Heating
Duct Ducts
Cooling Duct Location R -Value Tested? Status
Zone #6 Ducted
Ducted Conditioned 6.0 IZ New
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
ft
c:
o
75
Q75
—
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
.
Qt HP
Plenum
Outside Buried
❑
Ener Pro 5.1 by Ener Soft User Number: 3665
RunCode: 2011-06-29T09:40:42 ID: Pae 15 of 15
Reg: 211-N0031754A-000000000-0000 Registration Date/Time: 2011/06/29 13:21:26 HERS Provider: CalCERTS, Inc