Loading...
13-1184 (BLCK) Structural CalcsT v Structural Ca Ic'u- la tions BodaI U RECEIVE, rj, Residence SEP 19200 °^qMUIVI_ 4�'r��- 53485 Humb-olt Blvd. EVE�(ar.�,:;��,� . La Quinta, CA September 10, 2013 Retaining.,Wall D'es'ign Scope of Work: CITY OF LA QU1 e� �FE1TY DEPT. A FOR CONS UCTION DATE �4 JHA James G. McIntosh Architecture and Engineering 73-995 EI Paseo, Suite 201 Palm Desert, CA 92260 (760) 346-6155 FAX: (760) 346-8842 v Page No. —L of IPages Date: SEPT. 10, 2013 Job Name: Bodal James G. McIntosh Calculation By. J. MAC Architecture and Engineering Checked By. Table of Contents Design Criteria ........................ Wall A Design ............................................... Pg LO Wall B Design Pg Soils Report .......................................... Pg — C 0 D E C O N F O R M A N C E All Construction Shall Comply with the 2010 California Residential Code, which adopts the 2009 IRC, 2009 UMC, 2009 UPC and 2008 NEC. Section R106.2 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONST CTION QATE 13 JHA James G. McIntosh Architecture and Engineering Design Criteria I Wind Ps= �\ kzt I ps30 (6—)) 95 MPH. Basic Wind Speed kzt=1.0 (SEC 6.5.7) 9 s = 20.44 PSF. Page No. 20" of Pages Date: SEPT. 10, 2013 Job Name: BOdal Calculation By. J. MAC Checked By. ALLOWABLE SOIL _ RLSS JRL 1,500 PSF. Basic. Increases: h 250 PSF for EACH ADDITIONAL 1 FT. of WIDTH 250 PSF for EACH ADDITIONAL 6 INCHES of DEPTH MAX. ALLOWABLE BEARING PRESSURE = 2500 PSF. SEE ATTACHED SOILS REPORT CITY OF LA QUINTA BUILDING & SAFETY,DEPT. APPROVED FOR CONSTUCTION DATE -`6 B �mn FTG. z° 0 ° z �D OVERBURDEN 31-011 _�_ I 1 \y\! ------ - I N G T-01111 WIND LOAD 4'- 0" JMA Architecture Inc. JM>a73-995 EI Paseo Suite 201 '_/ Palm Desert, CA 92260 Architecture and En91n-1.9 (760) 346-6155 Cantilevered Retaining Wall Description : Retaining Wall A Criteria 1,980 psf OK Retained Height = 7.00 ft Wall height above soil = 4.00 ft Slope Behind Wall = 0.00:1 Height of Soil over Toe = 36.00 in Water height over heel = 0.0 ft Vertical component of active 110.00 pd Lateral soil pressure options: 110.00 pcf NOT USED for Soil Pressure. 0.400 NOT USED for Sliding Resistance. NOT USED for Overturning Resistance. Surcharge Loads 12.00 in i Lateral Load Applied to Stem 1,278.0 lbs Lateral Load = 0.0 plf Surchargge Over Heel Used To Resist Sliding & Overturning 35.0 psf Surcharge Over Toe = 35.0 psf Used for Sliding & Overturning 30.00 Axial Load Applied to Stem i Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Design Summary i Wall Stability Ratios Overturning = 1.82 OK Sliding = 3.91 OK Total Bearing Load = 3,191 lbs ...resultant ecc. = 11.59 in Project Title: Engineer: Project ID: Project Descr: Soil Data 1,980 psf OK Allow Soil Bearing = 2,500.0 psf Equivalent Fluid Pressure Method 2,500 psf Heel Active Pressure = 35.0 psf/ft Toe Active Pressure = 35.0 psf/ft Passive Pressure = 250.0 psflft Soil Density, Heel = 110.00 pd Soil Density, Toe = 110.00 pcf Friction Coeff btwn Ftg & Soil = 0.400 Soil height to ignore 1,036.3 lbs for passive pressure = 12.00 in i Lateral Load Applied to Stem 1,278.0 lbs Lateral Load = 0.0 plf ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Soil Pressure @ Toe = 1,980 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe _ 2,267 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 6.2 psi OK Footing Shear @ Heel = 0.5 psi OK Allowable = 75.0 psi Sliding Calcs (Vertical Component NOT Used) Lateral Sliding Force = 1,036.3 lbs less 100% Passive Force = - 2,776.9 lbs less 100% Friction Force = 1,278.0 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 :1 Stability = 0.0 lbs OK Load Factors Wind on Exposed Stem = 20.4 psf Stem Construction Design Height Above Ftg Wall Material Above "Ht" Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data -- Printed: 12 SEP 2013. 2:0617M File = c:lUsersgim.JMAID000ME-11ENERCA-lftdal.ec6 ENERCALC, INC. 1983-2013, Build:6.13.8.31,*Ver.6.13.8.31 Calculations per ACI 318-05, ACI 530.05, IBC 2006, CBC 2007, ASCE 7.05 ( Adjacent Footing Load 2nd Adjacent Footing Load = 0.0 lbs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Fig CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil 8.00 _ at Back of Wall - 0.0 ft Poisson's Ratio = 0.300 Top Stem 2nd 3rd Stem OK Stem OK Stem OK ft = 7.00 3.00 0.00 = Masonry Masonry Masonry in = 8.00 8.00 12.00 _ # 5 # 5 # 5 in = 32.00 16.00 8.00 = Center Edge Edge fb/FB + fa/Fa = Total Force @ Section lbs = Moment.... Actual ft -1= Moment..... Allowable ft -I = Shear..... Actual psi = Shear..... Allowable psi = Wall Weight psi = Rebar Depth 'd' in = Lap splice if above in = Lap splice if below in = Hook embed into footing in = Masonry Data 84.0 fm psi = Fs psi = Solid Grouting Dead Load 1.200 Modular Ration' Live Load 1.600 Short Term Factor Earth, H 1.600 Equiv. Solid Thick. Wind, W 1.600 Masonry Block Tyl Seismic, E 1.000 Masonry Design M 0.207 0.490 0.496 81.8 406.3 826.3 163.5 953.0 2,801.9 789.8 1,986.1 6,158.6 1.8 6.4 7.7 38.7 38.7 38.7 58.0 84.0 133.0 3.75 5.25 9.00 30.00 30.00 30.00 30.00 30.00 7.00 30.00 30.00 7.00 1,500 24,000 No 21.48 1.000 in = 4.90 1,500 1,500 24,000 20,000 Yes Yes Yes Yes 21.48 21.48 1.000 1.000 7.60 11.60 thoQIT"v' OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONS RUCTIO DATE {U� B JMA Architecture Inc. Project Title: JHA� 73-995 EI Paseo Suite 201 Engineer: Project ID: Palm Desert, CA 92260 Project Descr: . ! 0 Atchitect- and Engineadng (760) 346-6155 511 Cantilevered Retaining Walt Description : Retaining Wall A Footing Dimensions & Strengths Toe Width = 3.00 ft Heel Width = 1.08_ Total Footing Width = 4.08 Footing Thickness = 18.00 in ' Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft fc = 2,500 psi Footing Concrete Density Fy = 60,000 psi = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm.= 3.00 in ti File = ' ENER Footing Design Results Toe Heel -Factored Pressure = 2,267 0 psi Mu' : Upward = 7,981 0 ft -Ib Mu' : Downward = 3,813 68 ft -Ib Mu: Design = 4,168 68 ft -Ib Actual 1 -Way Shear = 6.17 0.54 psi Allow 1 -Way Shear = 75.00 75.00 psi Toe Reinforcing = # 5 @ 8.00 in Distance Heel Reinforcing = # 4 @ 0.00 in Item Key Reinforcing = None Spec'd ft Other Acceptable Sizes & Spacings Toe: Not req'd, Mu < S' Fr it Heel: Not req'd, Mu < S' Fr Heel Active Pressure = Key: No key defined 2.83 Printed:12 SEP 2013. 2:06PM INC. 19n2013, Build:6.13.8.3f, Ver:6.13.8.31 Summa of Overturning & Resisting Forces & Moments :....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item lbs ft ft -Ib lbs it ft -Ib Heel Active Pressure = 1,264.4 2.83 3,582.4 Soil Over Heel = 61.6 4.04 248.9 Surcharge over Heel = 94.7 4.25 402.3 Sloped Soil Over Heel = Toe Active Pressure = 554.4 1.50 -531.6 Surcharge Over Heel = 2.8 4.04 11.3 Surcharge Over Toe = 50.1 2.25 -112.8 Adjacent Footing Load = Adjacent Footing Load = Axial Dead Load on Stem = Added Lateral Load = ' Axial Live Load on Stem = Load @ Stem Above Soil = 81.8 10.50 858.5 Soil Over Toe = 990.0 1.50 1,485.0 Surcharge Over Toe = 105.0 1.50 157.5 Stem Weight(s) = 967.0 3.40 3,289.8 Earth @ Stem Transitions = 146.7 3.83 562.2 Total = 1,036.3 O.T.M. = 4,198.9 Footing Weight = 918.0 2.04 1,872.7 Resisting/Overturning Ratio = 1.82 Key Weight = Vertical Loads used for Soil Pressure = 3,191.1 lbs Vert. Component = Total = 3,191.1 lbs R.M. = 7,627,5 ' Axial live load NOT included in t tal displayed, or used for overturning resistance, but is included for soi pressure calculation. CITY CIF (meq QUINTA 13UILDING & SAFETY DEPT. APPRov�� FOR • II�'N.0 3'-0" #5@8.in @Toe Designer select #4@0.in T-0" all orz.ren.d @ Heel 4'-1 C ITa P CCOF LA QU IN TABUIL BUILDING &SAFETY DEPT FARPR0VED RUCTION DATE IE3 3 8.in Mas w/ #5 @ 32.in o/c 8. in Mas w/ #5 @ 16.in o/c Solid Grout 2 3/4" T -O" Y I WALL CAP PER 0/44 --�� L1 1 1 I 1 I 1 EXTERIOR PLASIM to .� I . 1 8 GREY CONCRETE BLOCK. I GROUT d MW ABV• RETAfM 1 I OROLR ALL CELLS SOLD I --------------OW 71x5 LE WATERPROOF SAM SDE of WALL W14M RETAP" OOCIIRS Fr- VARMS FROM M8 to 979.8 +/- PLANTM AREA —� 1 1 I 1 1 ------------- .r cut. —4_ U . 9 PROPW I VI LM 9876 i• I I) I I 1• I - 0 I 1 I 1• cD 1 Q 1� Q i t� 0 tlI J � I• b z 1 1 I• t 1 EX OMP PLASTER to i• MATCH B1XDPIG 1 1� 1 1 'I i I 1• 'I 1 I LOT 66 I PAQ b n 51 V z z L.LJ ry 21:56c 1 1��A ��,"�1G &-SAFETY DEPT. PPROVED R CON§TRUCTAON DATE B RETAINING WALL B JMA Architecture Inc. Project Title: JHA73-995 EI Paseo Suite 201 Engineer: Project ID: f r Palm Desert, CA 92260 Protect Descr: Mehit-t- and Engineering (760) 346-6155 04 0 Cantilevered Retaining -Wall Description: Retaining Wall B Criteria 1,770 psf OK Retained Height = 5.00 ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 36.00 in Water height over heel = 0.0 ft Vertical component of active Footing Shear @ Heel = Lateral soil pressure options: Allowable = NOT USED for Soil Pressure. Sliding Calcs (Vertical Component NOT Used) NOT USED for Sliding Resistance. NOT USED for Overturning Resistance. Surcharge Loads - 2,205.8 lbs Surchar_gge Over Heel = 35.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 35.0 psf Used for Sliding & Overturning ...Height to Top = Axial Load Applied to Stem ...Height to Bottom = Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Design Summary Wall Stability Ratios Overturning = 1.87 OK Sliding = 6.24 OK Total Bearing Load = 2,202 lbs ...resultant ecc. = 8.53 in Soil Pressure @ Toe = 1,770 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,123 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 9.9 psi OK Footing Shear @ Heel = 3.2 psi OK Allowable = 75.0 psi Sliding Calcs (Vertical Component NOT Used) Lateral Sliding Force = 494.9 lbs less 100% Passive Force = - 2,205.8 lbs less 100% Friction Force = - 880.0 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 :1 Stability = 0.0 lbs OK Load Factors Soil Data 1.200 Allow Soil Bearing = 2,500.0 psi Equivalent Fluid Pressure Method Short Term Factor Heel Active Pressure = 35.0 psf/ft Toe Active Pressure = 35.0 psf/ft Passive Pressure = 250.0 psf/ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pcf Friction Coeff btwn Ftg & Soil = 0.400 Soil height to ignore 58.0 for passive pressure = 12.00 in Lateral Load Applied to Stem 5.25 Lateral Load = 0.0 plf ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Wind on Exposed Stem = 20.4 psf Stem Construction -� Design Height Above Ftg Wall Material Above'Ht' Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB +fa/Fa Total Force @ Section Moment.... Actual Moment..... Allowable Shear..... Actual Shegr..... Allowable Wall' Weight Rebir Depth 'd' Lap splice if above Lap splice if below Hook embed into footing Masonry Data fm Fs Solid Grouting Dead Load 1.200 Modular Ratio'n' Live Load 1.600 Short Term Factor Earth, H 1.600 Equiv. Solid Thick. Wind, W 1.600 Masonry Block TyF Seismic, E 1.000 Masonry Design M Prirted:12 SEP 2013. 234PI,1 File = c:lUsersyim.JMAID000ME-lIENERCA-1%Wal.ec6 ENERCALC, INC. 19832013, Build:6.13.8.31. Ver.6.13.8.31 Calculations per ACI 318-05, ACI 530-05, IBC 2006, CBC 2007, ASCE 7-05 Adjacent Footing Load , Adjacent Footing Load = 0.0 lbs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil 8.00 _ at Back of Wall 0.0 ft Poisson's Ratio = 0.300 Top Stem 2nd Stem OK Stem OK ft = 5.00 0.00 = Masonry Masonry in = 8.00 8.00 _ # 5 # 5 in = 32.00 8.00 = Center Edge = 0.466 0.658 lbs = 122.6 424.9 ft -I = 367.9 1,641.9 ft -I = 789.8 2,495.7 psi = 2.7 6.7 psi = 38.7 38.7 psf = 58.0 84.0 in = 3.75 5.25 in = 30.00 30.00 in = 30.00 7.00 in = 30.00 7.00 psi = 1,500 1,500 psi = 24,000 20,000 = No Yes Yes = 21.48 21.48 = 1.000 1.000 in = 4.90 7.60 IT`Y` F LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTkkUCTION JMA Architecture Inc. Project Title: JHA 73-995 EI Paseo Suite 201 Engineer: Project ID: Palm Desert, CA 92260 Project Descr: A,ddt..t­ and Engineering (760) 346-6155 ftled:12 SEP 2013. 2:34P61 Cantilevered RetainingWall file=c.Wsershim.JMA\CocUME-11ENERCA-liwal.ec6. ENERCALC, INC. 1983-2013, Build:6.13.8.31, Ver:ISA3.8:31 Description : Retaining Wall B rF-ooting Design Resuits -� Footing Dimensions & Strengths I Toe Width = 2.00 it Toe Heel Heel Width = 1.08 Factored Pressure = 2,123 0 psf Total Footing Width = 3.08 Mu': Upward = 3,538 0 ft -Ib Footing Thickness = 12.00 in Mu': Downward = 1,483 151 ft -Ib Mu: Design = 2,054 151 ft -Ib Key Width = Key Depth = 0.00 in 0.00 in Actual 1 -Way Shear = 9.92 3.25 psi Key Distance from Toe = 0.00 ft Allow 1 -Way Shear Toe Reinforcing = 75.00 75.00 psi = # 58.00 in fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = # 4 1 0.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min. As % = 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm.= 3.00 in Toe: Not req'd, Mu < S' Fr Heel: Not req'd, Mu < S' Fr Key: No key defined Summary of t Nerturning & Resisting Forces & Moments OVERTURNING..... .....RESISTING..... Force Distance Moment Force instance Moment Item lbs ft ft -Ib lbs ft ft -Ib Heel Active Pressure = 630.0 2.00 1,260.0 Soil Over Heel = 227.3 2.87 653.2 Surcharge over Heel = 66.8 3.00 200.5 Sloped Soil Over Heel = Toe Active Pressure = -280.0 1,33 -373.3 Surcharge Over Heel = 14.5 2.87 41.6 Surcharge Over Toe = -14.5 2.00 -89.1 Adjacent Footing Load = Adjacent Footing Load = Axial Dead Load on Stem = Added Lateral Load = ' Axial Live Load on Stem = Load @ Stem Above Soil = 122.6 9.00 1,103.8 Soil Over Toe = 660.0 1.00 660.0 Surcharge Over Toe = 70.0 1.00 70.0 Stem Weight(s) = 768.0 2.33 1,792.0 Earth @ Stem Transitions = Total = 494.9 O.T.M. = 2,101.8 Footing Weight = . 462.0 1.54 711.5 Resisting/Overturning Ratio = 1.87 Key Weight = Vertical Loads used for Soil Pressure = 2,201.8 lbs Vert, Component = Total = 2,201.8 lbs R.M. = 3,928.3 ' Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVE FOR CONST UCTI N DATE BY 0 T -O" #5@8.in @Toe 8.in Mas w/ 95 0 32 in n1n Designer select #40O0.in all horiz. reinf. 1-4 @ Heel i r 3--1 CITY OF LA QUINTA BUILDING &SAFETY DEPT. APPROVED FOR CON RUCTION DATE 0 k