Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
06690 (SFD)
rY �� 4 P.O. BOX 1504 Building 7&105 CALLE ESTADO Address 79-�-Ift Horseshoe fZD , LA QUINTA, CALIFORNIA 92253 Owner T. tFeack Address 46-175 Je Aso -n City Zip Tel. La Ouintfl 92253 Address City lZip State Lic. I City & Classif. Lic- # Arch., Engr., Designer Address Tel. CityI Zip I State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and ..v SIGNATURE ,7-r+ - - i' DATE f f OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractors License Law for the following reason: (Sec.%7031.5,Business and Professions Code: Any city or county which requires a permit to construct, after, improve, demolish, or repair any shlocYrme, prior to its issuance also requires the applicant for such permit to fie a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penafty of not more than five hundred dollars (5500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale- (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon and who does such work himself or through his own employees, provided that such Improvements are not intended or offered for safe. 11 however, the building. or improvement is sold within one year of conpletion, the owner -builder will have the burden of proving that he did not build or inprove for the purpose of safe.) O I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License taw does not apply to an owner of property who bunds or krproves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ I am exempt under Sec. B. 8 P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Workers Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company - ❑ Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed If the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ anyperson in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions or the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Clivi Code.) Lenders Name Lenders Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I car ity that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above-. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip No. 06690 BUILDING: TYPE CONST. OCC: GRP. A.P. Number 617-112-025 ,Legal Description Project Description Sid? Sq. Ft. a0�a No. No. Dw. Size Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ •Demolition ❑ AQ FOOL Estimated Valuation $118,302 PERMIT AMOUNT Plan Chk. Dep. $250.00 Plan Chk. Bal. 341.03 Const. 706.00 Mech. 53.50 Electrical 133.97 Plumbing 157.50 S.M.I. 8.33 Grading 20.00 Driveway Enc. 20.00 Infrastructure 2,565,84 Jon ;'--" r :t.Jr.1'" ,,.. f v"^L� i ,^t 1 , � _ }•- TOTAL 54,256.17 14,� REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR 1. 11/x8/99 Issued by:-* Date Permit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FLIES, 1ST FL. SQ. FT. ® $ UNITS A.C. UNIT COLL, AREA SLAB GRADE YARD SPKLR SYSTEM 2ND FL Sp. FT. ROUGH PLUMB. BONDING HEATING (ROUGH) MOBILEHOME SVC. BAR SINK POR. SQ. FT. ® SEWER OR SEPTIAN GAR. SO. FT. ® POWER OUTLET ROOF DRAINS FOUND. REINF. f % C DRAINAGE PIPING CAR P. SO. FT. ® LOOP HEATING (FINAL) WALL SQ. FT. REINF. STEEL DRINKING FOUNTAIN. SQ FT ® GAS (FINAL) /� URINAL ESTIMATED CONSTRUCTION VALUATION $ ' WATER PIPING NOTE: Not to be used as property tax valuation FLOOR DRAIN MECHANICAL FEES FINAL INSP. WATER SOFTENER VENT SYSTEM FAN EVAP.000L HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRYTRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE,TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER. B.T.U. SQ. FT. ® c BATH TUB SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 11/. c SEWAGE DISPOSAL SQ.FT.GAR ® 3/ac HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING �� UNDERGROUND A.C. UNIT COLL, AREA SLAB GRADE �Z Q ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIAN ROUGH WIRING. DUCT WORK ROCK STORAGE FOUND. REINF. f % C _ AS (ROUGH) 1.7METER LOOP HEATING (FINAL) OTHER APPJEQUIP. REINF. STEEL GAS (FINAL) /� EMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM LUMBER GR. FRAMING ROOFING VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING 9(,j MESH INSULATION/SOUND 21/f/ FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL GARDEN WALL FINAL WATER SYSTEM FINAL INSP. FINAL INSP. WIV, GRADING cu. yd. $ plus x$ .g s 4.4 Qum& P.O. BOX 1504 APPLICATION ONLY Building rip_ ��5 �/ 7&105 CALLE CALIFORNIAESTAD9 Address / / /J.�.SF_ . r n F_ LA OUINTA, ORNIA 92253 Mailing I Address,L)/�_/%S tJ�FfE/�So� 121-2-9,3 - - Contractor. State Lic:I City & Classif. Lic. # Designer Address Tel. CityI Zip I State I Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that 1 am licensed under provisions of Chapter 9 (commencing with Section 7000) of tvision 3 of the Business and Professions Code, and my license is in full force and effect SIGNATURE DATE OWNER -BUILDER DECLARATION 1 hereby affirm that 1 am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Bmsiress and Professions Code: any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also therequires Me Provisions oContractors License Law, a fe a �Chaptened ra9 (commencing with tement that he is licensed ectio 000) of Dmision 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation o/ Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty o/ not more than five hundred dollars ($500). ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Protessions Code: The Contractor's License Law does not apply to an owner o/ property who builds or improves thereon and who does such work himself or through his. own employees, Provided that such mirprovements are not intended or offered for sale. d, however, the building Air improvement is sold within one year or compietion, the owner -budder will have the burden of proving that he did not build or improve for the purpose o/ safe.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts -for such projects with a corbactor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec B. & P.C. for this reason n Date / ! tTwrp� C 11'/ 0'"'e Z;to .. WORKERS' COMPENSATION DECLARATION 1 hereby affirm that 1 have a certificate of consent to self -insure, or a certificate of Workers Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is /or one hundred dollars ($100) vafuation or fess.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner oars to become subject- o the :T rs' Compensation Laws f mfo is Dat�Owner Gti ImfO PPi.hCAM: it, after nlgdffg this Certificate o/ Exemption u should become subject to the Workers' Compensalkxf provisions of the Labor Code, you must forthwith coney with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY 1 hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097 Civil Code.) Lenders Name-l�fid/�i O F7.�� ✓� SE? Lenders Address This is abuilding permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. 1 cerifty that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above- mentioned property fo risgection purpose Signature of appli . "'-442A Date Mailing Add F nit city,State Zip BUILDING DIVISION LDING: TYPE CONST. OCC. GRP. P. Number 7 I% Z 2 5 gal Description 07 3 oject Description Sq. Ft.No. No. Dw. Size 2 O Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Ll Alc7 �Ot� Estimated Valuation PERMITy, AMOUNT Plan Chk. Dep. 'L 5 !7, v 0 Plan Chk. Bal. qd Const. --70 • or Mech. Electrical / 7j Plumbing S.M.I. Grading 7-0.to Driveway Enc. 2OC;3 Infrastructure Z 147 TOTAL —2- 7 O, U o REMARKS 0e5 rzn AIN nc n 44 -JA -00 4 f1 ' r ..�'C--�.3.. o .. - f t� CASH i TpTAIL 1 250.00 -- ZONE: ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: CONSTRUCTION ESTIMATE GROUND PLUMBING NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SQ. FT. ® $ r UNITS BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING YARD SPKLR SYS EM 2ND FL. SO. FT. ® FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) ` 7i + REINF. STEEL MOBILEHOME SVC. TEMP. POLE BAR SINK POR. SQ. FT. ® GROUT WATER HEATER SERVICE FINAL INSP. GAR. SQ. FT. ® BOND BEAM POWER OUTLET IROOF DRAINS =$ LUMBER GR. FINAL INSP. DRAINAGE PIPING CARP. SQ. FT. ® ROOFING WALL SO. FT. ® 1.4 DRINKING FOUNTAIN VENTILATION FIRE ZONE ROOFING URINAL SQ. FT. ® FIREPLACE ESTIMATED CONSTRUCTION VALUATION $ SPARK ARRESTOR WATER PIPING NOTE: Not to be used as property tax valuation LATHING FLOOR DRAIN MECHANICAL FEES MESH WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN FINISH GRADING WASHER(AUTO)(DISH) APPLIANCE DRYER FINAL INSPECTION GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED CERT. OCC. LAUNDRYTRAY AIR HANDLING UNIT CFM INSPECTOR'S SIGNATURESIINITIALS KITCHEN SINK ABSORPTION SYSTEM B.T.U. GARDEN WALL FINAL 7d TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT ISHOWER BOILER B.T.U. SQ. FT. @ c BATH TUB SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 1114 c 3 SEWAGE DISPOSAL SO.FT.GAR ® 3/4c Fri- HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE L PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP. FRAMING FINAL INSP. ROOFING REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATION/SOUND FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL 7d 011ILE of AGRICUt_ I UIt(\l_ CU�1h1I551U(�IL'It ANO WI:IC;1 I I S b hI ASURES 49-613 Il,+y 1160 Msite 11-12 '01101ellit, CA 92136 619-341-0291 E. U011 51'n11r,Y co•a�u�lur..tn )n�11.5 U wALOCE A�S�SIA\I 1'; t�a•aiStnt�l.n CEEME.41 tO.NVEMSIE PUMA Cr1SC IIU.� UEVCLAPI:itt 5 l W l t tE U&�N� . T�UUIlES3 t r�(o• S • �zs�se-) A� • L `A • '1•r;E,c:l�l lulac t � � 1 .� Dear Developed n Eter >revlewLlg your lanclsccj11111k1 Itlallh, till {1lttnt 11�tVa17�eylisted 6ubslilutlivlls violation o[ yuarantlne 1t1+rs iiuveE111ny 1112 Wac"e do occur End they d11[er [r1_m Itlant nclteaul listed, this oC[ice nlusl be Itotil iecl iulu�diately . • Lor ttvlectLly a11d 1►Eeservllly the Coachella Valleys pest --[rte envirolment•. ,fila,>k you 1 � ny�icul.tui-ai _ 1 �.ssloiierle ul:[lc� ccs U1dlo and ltiverslde U[[1ce —7 � Fs / S 1-7Z62-"�*0 /AJ b,A-A1 "S, AI "e's (f,�C 4 Desert Sands Unified School District CERTIFICATION OF PAYMENT 0 �e9 SCHOOI4,A ITY FEES I W . ctnn TO: City of La ,Quisnt�a DATE: Depayr�tment O Community Development �T8-1'0.5-Gable Estado Qv � La Qu1innta, CA 92253 This is to certify that developer of YJA AQ which is located at_ f within this District, has paid school facility fees imposed pursuant to the authorityO g �at by Gov nment Cod S ctio 53080 in the amo nt of ( co a ing a total of square feet of ( ) residential or ( ) industrial/commercial development and that building permits for this footage in this development may now be issued by your jurisdiction. for ESERT SAND •UNIFIED SCHOOL DISTRICT White - Building Department • Yellow - Facilities Planning • Pink - Accounting • Gold - Developer (10)-37 MN Z O U W U)' X Z O U W U) .4 COUNTY OF RIVERSIDE ENVIRONMENTAL ~"iOf P'f°'I NO' HEALTH SERVICES DIVISION PERMIT APPLICATION FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM Appiksant: Submit this form with four copies of a scaled plot plan (1-20 scale) drawn to County speculations as indicated on the attached check list A non-refundable filing fee (see below) is required when the application is submitted. Check must be made payable to the County of Riverside. Approval of this application shall remain valid for a period not to exceed one year from date of approval. 40j /VERIFYj ITEMS IN SECTION A FROM BUILDING & SAFETY APPLICATION BUILDING DEPARTMENT APPLICATION LOG # Agent, Contractor, Contact Person Phone J Address 8 Firm r Ow^� 1 Phone ' Mailing Address k - ��,� Clty'' State Zip Job Property Address Legal Description Prop. (PM, Tract LW) 2z j 3 M&C fs/{oE T o4- O Loj Size- ! ter Agenc /Wath Use of Perron P/P, CU, eta Other Our CtW ,� , Al � Dwelling, MH Site Prep, etc. GJ Signature of Applicant Date CATEGORY: REV CODE FEE 4BW CATEGORY: REVCODE FEE FACE DISPOSAL 1238 7.00 ❑ SITE EVALUATION UPON REQUEST 7349 $ 43.00 O MULTIPLE PARCELS WITHIN SAME (NO PLOT PLAN) LAND DIVISION ❑ SEWER/SEPTIC VERIFICATION 7348, $ 17.00 a. 1:'6t'4 Parcels (Each) 1238 $ 57.00 (Less than 1 year) b. Each Parcel after 4 7344 $ 24.00 O PRELIMINARY ELECTIVE 7352 $ 23.00 O Rereview (2nd review same parcel) 7344 $ 24.00 EVALUATION (Attach DOH SAN 53) ❑ Site Evaluation in Conjunction.wtth ❑ HOLDING TANK 7351 $ 47.00 Critical Area 7348 $111.00 ❑ ALTERNATIVE/EXPERIMENTAL 7345 $222.00 O Site Evaluation Lot Less than) SYSTEM r 10,000' Sq. Ft. 7347 $ 87.00 I Holding Tank Agreements Completed ❑Yes Oallo / l�t�/ f —rl-1l / Certification of'Existing S.D. System Required O Yes WOCB Clearance required. (Attach Form O Yes o DOH SAN 007, Santa Ana Region Only) Solis Percolation Report Required. ❑Yes ❑,No Special Feasibility Boring Report Required. ❑ Yes Detailed Contour Plot Plans Required (1 to 5 ft interval) O Yes ❑0 - Other O Yes giNo Staff Specialist Lot inspection Required O Yes @--'No ' Lot Inspection Date i f Sills boring report by Date /�f//Prr� /� / Soils Map Page, Sol Type / _ D APPraed by ��Date No. of Systema /// Type Systems) ❑ HoldTank ❑ Existing No. Dwelling Unite (0 u Uing Bedrooms, [e (1) Septic Tank Soil RateGrease/Sand �G�� ❑ RepfaoertM rr 3 $ D A y �^ SSoQ Gal ye aft .,�Ir Gel qJ Leach Line Sq. Ft. ElMorn trench area Sidewall allowance fL rock/ sq. R lnsfall Une(s) It king f1 wide with Leach Bed sq. ft. �DofteL per running ft min. b� v drelnlines or area Leachlines/bed special design for slope: (3) Pit Diameter No. Pits Pit Below Seepage Pit Total Depth (TD) Applicable - / Inlet (BI) �'oZ y 8 / Max. Allowa�le D?pth N/AOverburden factor �O 0 No. 2 System REMARKS: - This application isPP}�OVfor the category checked in SECTION B above, regarding the design of a subsurface disposal system as indicated on the accompan�using the requirements set forth in SECTION C above. A building permit is necessary for the installation of the above -designed system. No construction is permitted in the required reserved 100% expansion area. (Septic tank and sewer lines must be 50' minimum from any wells q lo�'..R-P� ( Leach lines must be 100' minimum from any wells, including expansion ea (Seepage pits must be 150 minimum from any wells, including expansio area Signature of Health Official Date RECEIPT NO. 41 %bFL n '3 Issued By /� ���/1 �� Date _ DISTRICT: ❑ Riverside, ❑� ndio ❑ Hemet q Perris ❑ Rancho Calif. O Blythe 'DOH -SAN -122 (Rev. 7/89) DISTRIBUTION: WHITE - Office file YELLOW - Applicant PINK - Bldg. Dept GOLDENROD - Plans/Records 7 One Hundred Thirteen Corporation Indian Palms Country Club — Wagne RCC(ILT. PICSlderlt Thomas Pardo. Vice President Ron Sainz. Vice President October 23, 1989 Mr. Eugene Feack 46-175 Jefferson Street La Quinta, CA 92253 a Re: Lots 35 & 36 - Tract 2180 La. Quinta, CA Dear Mr. Feack: 4$630 Munroe Street Indio. California 92201 Phone (619) 347 0911 Please be advised that we have inspected ,your building sites and conclude that the water run-off from your rear yards poses no hazard to the golf course. The right to drain water onto the golf course does not include swimming pool drainage. or- hazardous chemicals that would damage the grass. Therefore, we grant ,you permission to grade the lots according to city requirements and to drain excess water onto the'golf course. Sincerely Thomas Pardo Vice President TP:bl 0 One Hundred Thirteen Corporation — Indian Patens Country Club — WVayne Reeder. President Thomas Pardo. Vice Prasideni Run Sainr., Vice President October 23, 1989 Mr. Eugene Feack 46-175 Jefferson Street La Quinta, CA 92253 Re: Lots 35 & 36 - Tract 2180 La Quinta, CA Dear Mr. Feack : 48 630 Monrue Street Indio, Calilornw 92201 Phone (619) 347 0941 Please be advised that we have inspected your building sites and conclude that the water run-off from your rear yards poses no hazard to the.golf course. The right to drain water• onto.the golf course does not include swimming pool drainage, or• hazardous chemicals that would damage the grass. Therefore, we grant .you permission to grade the lots according to city requirements and to drain excess water onto the golf course. Sincerely Thomas Pardo Vice President TP:bl PROJECT DATA SUMMARY owner \\ rproject system type documentation author date Form 1 checked by date SITE INFORMATION C I Heating Degree Day (from Appendix C) .......................................................... HDD 1 °F•day Outside Design Temperature (from Appendix C or Appendix G) ...................... Tow 2 ( OF PROPOSED BUILDING ENVELOPE INFORMATION Gross Floor Area if Low -Rise (from Calculations) ............................................ At 3 ` " ft2 Gross Wall Area if High -Rise (from Calculations) ............................................ Aw 4ft2 Designed Glazing Area (from Calculations)..................................................... A9 5 ft2 Basic Glazing Area (16% of Line 3 if low-rise or 40% of Line 4 if high-rise) ........ Abg 6 Z- � ft2 T Description of AssemDly J ` °F) Glazing 1� Ugl 7 Btu/ (hr • ft2 • U92 8 Btu/ (hr .ft2 •OF) _ �":-- U 9 9 Btu/ (hr •ft2 •°F) Wall 1 C�9� . Uwl 10 •oS Btu/(hr•ft2•°F) Uw2 11 Btu/ (hr. ft2 •°F) Uw3 12 Btu/ (hr • ft2 -OF) Uw4 13 Btu/ (hr. ft2 •)F) Ceiling/Roof \ s ` — Ucl 14 O7;•CO3 Btu/ (hr•ft2•°F) Uc2 15 Btu/ (hr •ft2 •°F) Floor Ufl 16 Btu/ (hr •ft2•OF) U12 17 Btu/ (hr.ft2 •OF) PROPOSED SPACE HEATING SYSTEM (Chapter 7) Gas Furnace Building Design Hourly Heat Loss (from Form 2) ..................................... q 18 Btu/hr Maximum Allowed Bonnet Capacity, 1.5 x Line 18 ............................................... 19 Btu/hr Proposed Furnace Make Model Description Rated Bonnet Capacity Electric Resistance Alone Electric Resistance Life Cycle Cost (from Form 5) .................................... sLCCe 20 S Lowest Life Cycle Cost of the Other Systems (from Form 5) ................... sLCC lowest 21 S Non•Depletable Energy w/Electric Resistance Back -Up Percentage of Annual Heat Loss Met by Non-Depletable Energy Source (from Calculations)............................................................................... 22 Heat Pump with Electric Resistance Supplementary Heat Percentage of Annual Heat Loss Met by Electric Resistance (from Calculations)•............................................................................................ 23 % PROPOSED WATER HEATING SYSTEM INFORMATION (Chapter 8). Electric Resistance Alone Electric Resistance Life Cycle Cost (from Form 6) . ................................. wLCCe 24 S Lowest Life Cycle Cost of the Other Systems (from Form 6) ................... wLCCbslml 25 S PROPOSED SWIMMING POOL HEATING SYSTEM INFORMATION (Chapter 9) Solar Life Cycle Cost (from Form 7)............................................................... pLCCs 26 $ Natural Gas Life Cycle Cost (from Form 7) ...................................................... pLCCng 27 $ HOURLY AND ANNUAL Form 2R BUILDING HEAT LOSS RATE (8/81) Check One: Proposed Design' Standard Design Enforcement Agency Use Only owner protect out oing permit numOar pro catlon system typecnecxea oY bocumentauon autnor pats aate SITE INFORMATION Heating Degree Day (from Appendix) . . . .. . ... .. .. . . .. HOD I Z 7�1 oF• day ^� 0 Outside Design Temperature (from Appendix) .. .. .. . . . . . . . Tow �> 1 F Outside January Mean Temperature (from Appendix) .. . . .. . . . . .. . T.Ian pF PROPOSED BUILDING ENVELOPE INFORMATION For Uninsulated-Floor Over Vented Unheated Space. .. .. .. . Line 2 - S'F 'AThu 3 1 Lq I 0 For Stab -on Ground Floors ........... 700F - qL) of -ATM 4 ! of Gross Floor Area (from plans) . . . .. . .. . ..... .... .. . . . . . At CONDUCTIVE HEAT LOSS Average U ft 2 Gross Well Area (from plans) .. ... .. . . ..... .. ... .. . . . . .. . Aw �' ft2 Designed Glazing Area (from plans) . . . . . . . . .. . . . . . . . . . . . . . Ag a Z Coal- ft2 Basic Glazing Area (16% of Af if low-rise or 40% of A,,if high-rise) . . . . . . .A-, X x = ft2 HOURLY HEAT LOSS DESIGN TEMPERATURE DIFFERENCE 2 9 For All Assemblies Other Than The Three Below . ..70oF - > I of ITh 1 l of Tow from above 0 'For Insulated Floor Over Vented Unheated Space .... .. .... Line 1 =2 -ATM 2 F a For Uninsulated-Floor Over Vented Unheated Space. .. .. .. . Line 2 - S'F 'AThu 3 F For Stab -on Ground Floors ........... 700F - qL) of -ATM 4 ! of Tian from above CONDUCTIVE HEAT LOSS Average U of Assembly, Area, ft2 or or F2 from CT hourly heat Description of Assembly Lon Graph Graph 4-1 from above S- �li �/� �� 1 1✓ �� loss, qO ��� Btu/hr Glazing x - x a S C(J� \ ���`UJA� .O rj (� X ' Wall X X x = ^� �p� '3= Caiiing/Roof ♦ L (��� \ 1 5O x "' �r x %.� a Floor.5 5-�_S x X —�— __,_�—_ --Ir = ( Other ri ► tbo X 1� 13i J L� = Z 6> volume Subtotal 5to/hr ' um o the above q INFILTRATION ...... 1 ft2 x �'�� ft x .d x 'F . 6 from l Al from above weigntea from Th Average Table 3-7 Line 1 Calling Height Subtotal 7Btu/hr n V T— 5 line io DUCT HEAT LOSS (Enter 0 if there are no ducts) . ... . . . .. ... . •.. . . 0.15 x Line 7 B :TOTAL "Fl0URL'Y HEAT LOSS, qL 9� Btu/hr ine7 line ANNUAL HEAT LOSS, aL of qday/Yr x L� 1 ` Btu/hr X 111.0 x 24 hr/day } _SaF 10 Cj \ Btu/yr HOO Hourly Heat Loss C from ., Tn from from above from Line 9 Table 3-8 Line 1 3-7 _.S DJ L C,A �4r-� wt�,-z,, 3 ao to 1 � _.S DJ L C,A �4r-� wt�,-z,, 3 ao �-= HEAT TRANSFER COEFFICIENT PROPOSED CONSTRUCTION ASSEMBLY Fora 3 ist of Construction Components R , >YVC. I �� 7 ���J �.• � ,yam s. �� g ' (9 O Inside Surface Air Film cooling heating Sketch of Construction Assembly Outside Surface Air Film V'T WEIGHT: Ib/ft2 IZ3�; cooling heating Check one: Total Resistance Rt Wall cooling heating Roof U -Value (1441tl,C� .Z1f �T Q,�03� . ���j(-P Floor ..— cooling heating HEAT TRANSFER COEFFICIENT PROPOSED CONSTRUCTION ASSEMBLY Form 3 .? List of Construction Components R 2. CIEo 3. 1 1J S v L�`n� ►J Ce 30� �� ,� 4. �Q ,1 1>Qv i,J /�.�� �L'� 5. 1 Z 6. 3 L{ 7. 8. Inside Surface Air Film Sketch of Construction Assembly WEIGHT: Ib/ft2 Check one: Wall Roof Floor Outside Surface Air Film Total Resistance Rt U Value'(f tl I l 1 , � L4 /t-�) 1(p .CMZ cooling heating zs ,iz cooling heating 3Z. 3 -9 I cooling heating cooling heating ,�10 , l BUILDING DESIGN AND EQUIPMENT SUMMARY F©l m 2 project title zone prolect dares proletLqnor documentation autnor date ' v--, A^� page 1 of 2 plan check/permit number CneCked by date -T-\ Typp 2 Enforcement Agency Use Only Com Oiiance method 1prescrletwe or :errrmance, describe) Type 3 ,,{G ft2 BUILDING Description of Item Dimension Points Type 4 __R HG 11t; ft2 �P Type 5 Total Floor Area SJ L./\I\-_D � � �`� 1. Floor:- Slab Perimeter, Type 1 1 �.1 F ft Ty 2 F, ft 7- �- �3aiczci, Type 1 1 EDF 11 i \ C-- OqL� D%f �-Li Type 2 C gZj0\7 (D t.G,D {t= , \ ) c, il ft2 Z Ceiling: Typa 1 Type 2 ft2 ` ` ►J S J l_,11 1 N TYpe ��-�i ft2 Q 3. Wall: i I Type 2 ft2 \ 4. Glazing: West, Type 1 ��-' ��'`� Zy \ % 4,3 fe Type 2 7Vl. L .4,J L r % ftz L.S� /, �Z ft - North. Type 1 Type 29" East, Type 1 n J A i h`-1 ft2 �° Z� ft2 Type 2 South, Type 1 DJ "\\-- f '"`� G „ ft: Z Y _�:.___ ft2 I Lj ' Type 2 %, .ftz Skylight, Type 1 IJ0 —�C ft2 Type 2 _SC 1`12 �A_ 1'� '� SC 5. Shading Coefficient: West North �I ' ?a % SC East `\ ' 1,� % Sc South Sc — Z 6. Horizontal South Overhang ZO ft A 7. Movable Insulation ft2 ^� 8, infiltration Control �\ �"� _ Zg ,� t3 PC Z� 1�Z ft: I 9. Thermal Mass:. Type 1 -T-\ Typp 2 fr Type 3 ,,{G ft2 Type 4 __R HG 11t; ft2 �P Type 5 Q }IC MG ft2 3 Point Total This Page 1/83 — 420 — CEC 284-66 (2/83) SUMMARY Form 2 page 2 of 2 oroiect title climate zone project address HEATING, VENTILATING, AIR CCNGITIONING SYSTEM Points 10. Heating (fill in information on proposed system) Central Gas Furnace 1�� Drano and model number SE C>D-z! Btu/hr neating capacity Heat Pump brand and model number Btu/hr nearing capacity at 47—F ACOP Active Solar type (liquid or air) collector brand and model number fta O collector area collec:or orientation collector tilt rated y - Interceot Other solar fraction rated slope describe 11. Cooling (fill in information on proposed sy stem) E'.eciric Air ConditionerL- orand and model number seasonal EER (` S2 c) -`o Btu/hr cooling caoauty at 95 F Electric Heat Pump E�2 Btu/hr cooling capacity at 950 F I Other describe 12. Mechanical Ventilation describe DOMESTIC WATER SYSTEM 13. Heating (fill in information on proposed system) Gas Only Gallons brand and model number tank size , Heat Pump w/Electric Backup Gallons brand and model number tank size Active Solar_ collector brand and model numberated rated slope solar traction y - �ntercept ft2 backup neater type, brand and model number collector area collector orientation Other describe Point Total from Page 1 V Total Point Score } 1183 - 420 - CEC (E1 G16WSERIES — UP F O GAS O ° III FURNACES 50,000 to 100,000 Btuh Input Add -On Cooling — 1 thru 5 Nominal Tons Typical Applications Closet Installation with cooling coil and electronic air cleaner. Basement Installation with cooling coil, return air cabinet and power humidifier. M�ilOy� y < o c�i O CrcTIRIU � Aluminized Steel Burners �ama� Lennox DURACLIRVEa Aluminized Steel Heat Exchanger r. ENGINEERING DATA HEATING UNITS GAS Page 9 May 1984 Supersedes October 1983 Lennox G16 Series Up -Flo Gas Furnaces Feature High Efficiency Operation and Installation Versatility The G16 series line of gas fired furnaces include six models (natural gas or LPG) with Btuh input capacities of 50,000, 75,000, 100,000 and energy efficiencies (AFUE) of 80% or above. Compact, stand- ard size cabinet size, with side or bottom return air entry, will allow installation in a basement, closet, recreation or utility room. Op- tional return air cabinets are available to simplify return air duct �connection to the furnace. The matching return air cabinet may be installed on either side of the furnace. Lennox add-on evaporator �oils, electronic air cleaners and power humidifiers can easily be cldecl to the furnace for a cgmplete all season installation. Units are equipped with the gas saving automatic POWERLITEt'" pilot ignition system. Pilot flame is on only dur- ing main burners operating cycles. No need to shut off pilot dur- ing air conditioning season. Flue draft will be created by a induced NOTE — Specifications, Ratings and Dimensions subject to change without notice. draft blower mounted on the flue collector box on the outlet of the heat exchanger. The furnaces can be vented vertically as a common vent with another appliance. G16 series furnaces are design certified by A.G.A. Laboratories and ratings are certified by GAMA. Units have been rated and tested according to Department of Energy (DOE) test procedures and Federal Trade Commission (FTC) labeling regulations in the Lennox Research Laboratory. G16X (natural gas) models meet the California Nitrogen Oxides (NOx) Standards and California Seasonal Efficiency requirements. Blower data is from unit tests conducted in the Lennox Laboratory air test chamber. Units are shipped factory assembled with all controls installed. Each unit is factory test operated insuring proper operation. Installer has only to make flue vent, gas supply and electrical connections. I 5V1:(;11-IL:A I IUNS Model No. ttG16Q2X-50 G16Q2-50 tTG16Q3X-50 G1603-50 TtG16C 3X-75 G1603-75 ttG16Q4X-75 G16Q4-75 ttG16Q4X-100 G16Q4-100 ttG16Q5X-100 G16Q5-100 Input Btuh 50.000 50.000 75,000 75,000 100,000 100,000 Output Btuh 41,000 41,000 61,000 61,000 81,000 81,000 tA.F.U.E. 81.0% 81.0% 80.0% 80.0% 80.1% 80.1% California Seasonal Efficiency 1 76.095 78.3% 77.0% 78.4% 76.4% 77.5% Temperature rise range (OF) 35 — 65 20 — 50 35-65 25 — 55 35-65 25 — 55 High static certified by AGA (in. wg) 50 .75 .50 .75 .50 .75 Flue size connection (in. diameter) 3 3 3 3 3 3 Gas piping size I.P.S. (in.) natural or LPG 1/2 1/2 1/2 1/2 1/2 1/2 Blower motor horsepower 1/4 1/3 1/3 1/2 1/2 3/4 Blower wheel nominal dia. x width (in.) 9 x 7 10 x7 10 x 7 10 x 8 10 x 8 12 x 12 Net filter area (sq. ft.) & cut size (in.) (5.8) 36 x 28 x 1 (5.8) 36 x 28 x 1 (5.8) 36 x 28 x 1 (6.6) 40 x 28 x 1 (8.9) 52 x 28 x 1 (8.9) 52 x 28 x 1 Tons of cooling that can be added 1, 1-1/2 or 2 2-1/2 or 3 2-1/2 or 3 3-1/2 or 4 2-1/2,3,3-1/2or4 4 or 5 Shipping weight (lbs.) — 1 Package 160 165 170 195 240 260 Electrical characteristics 120 volts — 60 hertz — 1 phase (less than 12 amps) — All Models Return Air Cabinet (0otional) I Model No. RA10-16-49 RA10-16-49 RA10-16-49 RA10-16-49 RA10-16-53 RA10-16-53 IShipping Wt. (lbs.) 54 54 54 54 56 56 'LPG Kit — Optional LB-33151CAD (All Models) tAnnual Fuel Udization Efficiency based on DOE test procedures anc according to FTC labeling regulations. 'LPG Kit must be ordered extra for field changeover. ttNot available with LPG. HIGH ALTITUDE DEBATE A.G.A. INSTALLATION CLEARANCES Sides 1 inch Rear 1 inch Top Front 1 inch 6 inches Floor Combustible 'Flue '4 inches 'This is clearance to all flue pipes except type "B". Type "B" vent clearance is as listed by U.L. NOTE — Flue sizing and air for combustion and ventilation must conform to the methods outlined in American National Standard (ANSI -2223.71 National Fuel Gas Code. G16 SERIES FURNACES ,73/4UCSOFEN'..PLY } 1.1/16 S1/8 77.13/16 1-11/16 267/8 69+/ 16 1 17-1/2 (Lett) 21-1/2 GAS PIPING INLETS Might) tbol[h eild_I Ll 2.3/8 A ELECTRICAL INLETS Iboth aid -I O o r�---22 21/16 1 D RETURN AIR OPENING L I__lbot we_ _J t J+ . b nom) I I 1.1/2 I HE If the heating value of the gas does not exceed values listed in the table, derating of the unit is not required. Should the heating value of the gas exceed the table values, or if the elevation is greater than 6,000 feet above sea level it will be necessary to derate the unit. Lennox requires that derate conditions be 4% per thousand feet above sea level. Thus at an altitude of 4000 feet, if the heating value of the gas exceeds 1000 Btu/ft', unit will require a 16% derate. Elevation Above Sea Level (feet) Maximum Heating Value (Btu/ft') 5001 — 6000 900 4001 — 5000 950 3001 — 4000 1000 2001 — 3000 1050 Sea Level — 2000 1100 DIMENSIONS (inches) AIRFLOW C Model No. A B C D E I F I G G1602(X)-50, G16Q3(X)-50 G1603(X)-75 49 16-1/4 14-1/8 14 11 2-5/8 5 G16Q4(X)-75 49 21-1/4 19-1/8 14 14 3-5/8 7-1/2 G1604(X1-100, G16Q5(X)-100 53 26-1/4 24-1/8 18 21 2-5/8 10 —10a— RETURN AIR CABINET 4 17-3/4NOTE — Return Air Cabinet shipped knocked 14 RETURN AIR down and must be OPENING field assembled. 26.118 — . 1f— 16 A r— ----� I 2 22.1/8—r W. I B RETURN AIR I KNOCKOUT (both sides) -' L— ------ 1.1 rz Model No. RA10-16-49 RA10-16-53 A 49 53 B 14 18 l a17N HS18 SERIES EXPANSIOVALVE SYSTEM CONDENSING UNITS t (1 thru 5 Nominal Ton) *12,300 to 60,000 Btuh Cooling Capacity 'DOE and ARI 210 Standard Ratings Lennox HS18 Series Condensing Units Provide Low Cost Installation With Maximum Cooling Efficiencies High efficiency, compact size and operational dependability have been featured in the design of the HS18 series of condensing units. Available in 1 thru 5 nominal ton sizes with seasonal energy effi- ciency ratings of up to 10.20 and cooling capacities of 12,300 to 60,000 Btuh. Units are applicable to expansion valve systems and are compatible to a variety of matching Lennox blower powered and furnace add-on evaporator units, See Selector table. For complete data see evaporator unit bulletins indexed in Coils - Blower Coil Units section. Compact design of condensing unit cabinet and vertical discharge of air provides ease of concealment for installation on a slab at ground level or on a roof. c Weather resistant Cabinet is constructed of galvanized steel with a baked -on outdoor enamel paint finish for maximum protection from rust and corrosion. Extra large four sided wraparound coil provides maximum cooling efficiency. Additionally, cooling effi- ciency is increased by the use of durable copper tubing and ripple - edged aluminum fins. Powerful direct drive fan with totally enclosed motor draws air thru the entire coil and discharges it up and away from shrubs and lawn. Rugged, PVC coated steel wire fan and coil guards are furnished. Compressor is protected from excessive current and temperatures. Electrical control box is located for easy access. Service valves and refrigerant line connections are exter- nally located. Available as options to be ordered extra are; ther- mostat, timed -off control, low ambient kit, start kits, crankcase heater, mounting base and refrigerant line sets Condensing units are shipped completely factory assembled, piped and wired. In addition, each unit is test operated at the factory to ensure proper operation. The installer has only to set condens- ing unit in the desired location, connect refrigerant lines and make electrical connections to complete a low cost installation. ENGINEERING DATA COOLING UNITS CONDENSING UNITS Page 27 July 1, 1983 Supersedes 9-15-K �[e,�[K•.iON •>v, �[S ONI. US[D wilN[>uDY[P n.[N us[o..+�N .nu.[n cD .aN[N�s •s us.[D ca.•voN�N�s •s usnD wuN •v. Typical Applications Unit on slab at grade level NOTE - Specifications, Ratings and Dimensions subject to change without notice. Multiple units on rooftop •n r i I SPECIFICATIONS Model No. I HS18-411-413 HS18-461-463 HS18-511-513 HS18751-653 Condenser Net face area Isq. ft.) Outer coil 9.2 9.2 18.2 18.2 Inner coil I 5.1 8.6 5.4 7.5 Coil Tube diameter (in.) & No. of rows I 3/8 - 1.56 3/8 - 2 3/8-- 1.29 3/8 - 1.41 8.7 Fins per inch I 20 20 20 20 Condenser Diameter (in.) & No. of blades 18 - 4 18 - 4 22 - 4 22 - 4 Motor hp 1/6 1/6 1/3 1/3 Fan Cfm (factory setting) 2500 2400 3900 3800 1.2 Rpm (factory setting) 1050 1050 1075 1060 Watts (factory setting) I 260 265 400 420 'Refrigerant - 22 charge furnished 11 5 lbs. 14 oz. 6 lbs. 11 oz. 8 lbs. 6 oz. 9 lbs. 9 oz. Liquid line (o.d. in.) connection (sweat) 11 3/8 3/8 3/8 3/8 Suction line (o.d. in.) connection (sweat) 11 3/4 7/8 7/8 1-1/8 Shipping weight (lbs.) 1 Package 11 167 187 215 245 'Refrigerant charge sufficient for 25 ft. length of refrigerant lines. FIELD WIRING LENNOX I DISCONNECT I I THERMOSTAT I I DISCONNECT I ulnI ` SWI not furnished (optional) uTCH I nn by Lennox) by Lennox) I A -Two wire power (not furnished) g B - Two or Three wire power (not furnished) - See electrical data . C C - Two wire low voltage (not furnished) - 18 ga. minimum I D - Four wire low voltage (not furnished) - 18 ga. minimum LENNOX CONDENSING LE UNIT All wiringmust conform to NEC and local electrical codes. HE..TING ING UNIT U OR 'CB EVAPORATOR 'CB blower -coil evaporator unit applications require a separate 20 VA (minimum rating) transformer. ELECTRICAL DATA Model No. Model No. I HS18-141 HS18-211 HS18-261 HS18-311 HS18-411 HS18-413 Line voltage data 208/230v 1208/230v 208/230v 208/230v 460v 208/230v 208/230v 460v 60hz - 1 o 60hz - 3 h 60hz - 1 ph 60hz - 3 h 60hz - 3 h 60hz - 1 ph 60hz - 3 h 60hz - 3 h 208.'230v 60hz - 1oh 208/230v 60hz - 1 h 208/230v 60hz - 1 h 208/230v 60hz - 1 h 208/230v 60hz - 1 h 208/230v 60hz - 3oh 460v 60hz - 3oh Compressor Rated load amps 5.8 8.7 12.4 14.0 17.6 11.5 5.1 Power factor I .98 .95 .98 .97 .98 .88 .88 2.0 Locked rotor amps I1 31.0 49.0 65.0 81.0 88.0 65.0 33.0 Condenser Coil Fan Motor Full load ams 11 1.2 1.2 1.2 1.2 1.2 1.2 .7 Locked rotor ams 1 2.2 2.2 2.2 2.2 2.2 2.2 1.3 Recommended max. fuse or circuit breaker size (amps) 15 20 25 30 40 25 15 *Minimum circuit ampacity 8.5 12.1 16.7 18.7 23.2 15.6 7.6 Model No. HS18-461 I HS18-463 HS18-511 HS18-513 HS18-651 HS18-653 Line voltage data L10-26-25 25 208/230v 1208/230v 208/230v 208/230v 460v 208/230v 208/230v 460v 60hz - 1 o 60hz - 3 h 60hz - 1 ph 60hz - 3 h 60hz - 3 h 60hz - 1 ph 60hz - 3 h 60hz - 3 h Compressor Rated load amps 21.2 1 13.3 23.7 14.7 7.0 25.8 16.5 8.7 Power factor .98 .88 .98 .88 .88 .94 .88 .88 Locked rotor amps 108.0 74.0 116.0 92.0 46.0 142.0 107.0 53.0 Condenser Coil Fan Motor Full load ams 1.2 1.2 2.0 2.0 1.1 2.0 2.0 1.1 Locked rotor ams 2.2 I 2.2 4.5 4.5 2.3 4.5 4.5 2.3 Rec. max. fuse or circuit breaker size (am s) 45 .30 50 35 15 60 35 20 "Minimum circuit ampacity 1 27.8 18.0 31.8 20.5 10.1 34.5 22.9 1 12.2 'Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements. NOTE - Extremes of operating range are plus and minus 10% of line voltage. - REFRIGERANT LINE KITS INSTALLATION CLEARANCES (inches) Condensing Unit Model No. Line Length of Set Suct. & Liq. Model No. Lines (ft.) Liquid Line (o.d. in.) Suction Line (o.d. in.) HS18-141 HS18-211 HS18-261 L10-26-20 20 3/8 5i8 L10-26-25 25 3/8 5r8 L10-26-35 35 3/8 5r8 L10-26-50 50 3/8 5i8 HS18-311 HS18-410 L10-41-20 20 3/8 3!4 L10-41-30.. 30 L10-41-40 40 L10-41-50 50 HS18-460 HS18-510 L10-65-30 30 3/8 7/8 L10-65-40 40 L10-65-50 50 HS18-650 'Not Available 3/8 1-1/8 NOTE - Specify correct line kit model number when ordering. 'Field fabricate. -27b- NOTE - 48 inch clearance required on top of unit. *NOTE - One side must be 36 inches for service. Two of the remaining sides may be 12 inches. *Sound Rating Number in accordance with ARI Standard 270. � Kit is optional and must be ordered extra for field installation. -Furnished as standard with coil. 'Rated in accordance with ARI Standard 210 and DOE; 450 cfm (maximum) evaporator air volume per ton of cooling, 95°F outdoor air temperature, 80OF db/67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. -Denotes blower powered evaporator. tStart Kit is required for field installation with 1 phase model condensing units and must be ordered extra. See Repair Parts Cross Reference List for kit requirement. RATINGS NOTE- To determine sensible capacity, leaving wet bulb and dry bulb temperatures not shown in the tables, see Miscellaneous Engineering Data section, Page 9. HS18-141 WITH C16-18FF EVAPORATOR UNIT 'ARI Standard 210 Ratings Outdoor Air Temperature Lennox Evaporator Unit Condensing Unit SEEREER Enter. Total 8595 -_Expansion Model No. 105 Cooling Total Dehumid- Total Comp. Sensible (Btuh/ (Btuh/ Sensible Wet Sensible Sensible Air Total Comp. Total Comp. Bulb Vol. Cool Valve *ARI Standard Total Cool Capacity Unit ifying Up -Flo Down -Flo Horizontal Cool Cool Motor Watt) Watt) (°F) (cfm) Ca Watts Ratio (S/TI Kit 270 SRN (bels) Ratio ISM p' (Btuh) Watts Capacity Watts Ratio ISM 1 phase 3 Phase D Bulb (°F) (Btuh) Input D Bulb (°F) (Btuh) Input 8.10 7.70 31.600 4100 1 23% "CB11-41FF "CB11-41FF 76 84 LB-25778CB 8.40 7.85 32,000 4070 1 27% CR4-41 FF 76 8.65 8.15 32,000 3916 1 32%CH3-41-2FF 76 80 84 350 8.55 8.10 33,200 40% 1 25% C16-31 FF .81 .93 1.0011 11,000 1200 9.05 8.40 34,600 4122 1 28% ---- -- CH3-51-2FF 1060 HS18-411 .98 1.00 12,000 1140 .87 1.00 1.00 11,400 1220 .89 1.00 1.00 10,900 (Use SEER) 8.90 8.25 35,200 4279 I 21% C1641WFF .90 1.00 1.00 LB-25778CF 9.00 8.30 35,800 4303 I 21% C16-46FF C16-46WFF ____ ____ HS18-413 1.00 1.00 (Use EER) 9.00 8.35 36,000 4320 1 22% - CR4-51 FF ---- .75 .86 11,700 8.75 8.35 36,600 4393 I 21% t"CP12-41V t"CPR12-41V t.'CPS12-41/46V -Factory (8.0) .65 .78 .91 12,800 1160 .66 /E1203 /ES12Q4 /ES12Q4 Installed 11,300 8.95 8.45 36,600 4330 21% "CB10-51 •'CB10-51 •"C810-51 .83 .97 13,000 9.00 8.45 36,800 4354 I 20% --- -- CH16-51FF .74 .92 1.00 9.65 8.85 36,800 4150 I 21% ---- 13,400 "CB15-900/41 LB-25778CF .58 .69 12,600 9.25 8.65 37,600 4351 1 19% C14-41FF .47 t9 .71 11 900 8.15 .48 4799 1 0 425 14,500 1 1100 .47.60 .72 8.60 8.05 39,500 4910 I 27% C16-41 FF ____ 12,100 1340 .50 .65 .79 500 14 700 1100 C 16-41 W F F .63 .77 13 900 1190 .50 8.70 8.10 41,000 5069 I 23% C16-46FF .52 .69 .85 LB -25778C F HS18-461 C16-46WFF 8,75 8.15 41,500 1 5096 1 25% CR4-51 FF ---- (Use SEER) 8.65 8.10 42,000 5200 o 24/0 t"CP12-46V t"CPR12-46V t"CPS12-41/46V *Factory /E12Q4 /E12Q4 /ES12Q4 Installed tHS18-463 8,80 8.15 42,000 5145 I 24% "C610-51 "CB10-51 "CB10-51 (Use EER) 8.80 8.20 42,000 5118 1 24% C16-51FF ---- ---- 9.00 8.25 42,000 5082 1 25% CH16-51FF LB-25778CF (8.2) 9.40 8.70 43,000 4953 I 24% "CB15-900/46 9.00 8.25 43,500 5277 I 24% t"CP12-51V t"CPR12-51V ____ *Factory /E12Q4 /E12Q4 Installed 9.05 8.35 43 500 5215 1 23% C14-41 FF ---- ---- LB-25778CF 5200I 377. C 177777--- 9.15 8.45 46,500 5506 I 24% C16-46FF ____ ____ C 16-46W FF 9.15 8.45 47,500 5614 25% ____ CR4-51 FF HS18-511 CR4-65FF LB-25778CC 9.40 8.65 47,500 1 5485 1 29% CH 16-51 FF (Use SEER) 9.20 8.50 48.000 5631 24% C16-51 FF ---- ---- 9.25 8.55 48,000 5625 26% "C810-51 "CB10-51 "CB10-51 HS18-513 9.70 8.95 48,500 5430 1 27% ---- ---- "CB15-900/46 (Use EER) 9.35 8.65 49,000 5679 1 24% C16.65FF ---- 9.50 8.90 50,000 5630 26% "CP12-51V "CPR12-51V ---- -Factory (8.0) /E12Q4 /E12Q4 9.65 8.85 51,000 5754 24% CH16-65V Installed 10.20 9.35 51 500 5510 24% '•CB15-1200/65 9.75 8.95 52 000 5794 23% C14-65 LB-25778CC 8.15 53!500 6565 I o ---- --- 7.80 7.40 54,500 7360 26% "C810.65 "CB10-65 '•CB10-65 8.50 8.00 54,500 6809 27% CR4-65FF HS18-651 LB-25778CD 8.50 8.00 55,000 6877 26% C16-51FF (Use SEER) 8.60 8.10 57,000 7047 1 24% 1 C16-65FF ---- ---- HS18-653 9.25 8.25 58,500 7105 26% *'CP12-65V '"CPR12-65V -_-_ *Factory /E12Q5 /E12Q5 (Use EER) 8,85 8.25 59,000 7140 1 25% ---- ---- CH16-65V Installed (8.2)9.00 8.35 59,500 7106 26% C14-65 9.40 8.75 60 000 6870 24% •"CB15-1200/65 LB-25778CD *Sound Rating Number in accordance with ARI Standard 270. � Kit is optional and must be ordered extra for field installation. -Furnished as standard with coil. 'Rated in accordance with ARI Standard 210 and DOE; 450 cfm (maximum) evaporator air volume per ton of cooling, 95°F outdoor air temperature, 80OF db/67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. -Denotes blower powered evaporator. tStart Kit is required for field installation with 1 phase model condensing units and must be ordered extra. See Repair Parts Cross Reference List for kit requirement. RATINGS NOTE- To determine sensible capacity, leaving wet bulb and dry bulb temperatures not shown in the tables, see Miscellaneous Engineering Data section, Page 9. HS18-141 WITH C16-18FF EVAPORATOR UNIT NOTE - All values are gross capacities and do not include evaporator coil blower motor heat deduction. - 27d - Outdoor Air Temperature nterinq Condenser Coil (°F) Enter. Total 8595 105 115 Total Comp. Sensible Total Comp. Sensible Wet Sensible Sensible Air Total Comp. Total Comp. Bulb Vol. Cool Motor To Total Cool Motor To Total Cool Cool Motor To Total Cool Cool Motor To Total (°F) (cfm) Ca Watts Ratio (S/TI Ca p' Watts Ratio ISM p' Watts Ratio ISM p' Watts Ratio ISM (Btuh) Input D Bulb (°F) (Btuh) Input D Bulb (°F) (Btuh) Input D Bulb °F) (Btuh) Input Dr Bulb °F) 76 84 76 76 76 80 84 350 12,100 1050 .79 .91 1.00 11,600 1130 .81 .93 1.0011 11,000 1200 .83 1 .96 11.00 10,400 1270 .86 .99 1.00 63 425 12,700 1060 .84 .98 1.00 12,000 1140 .87 1.00 1.00 11,400 1220 .89 1.00 1.00 10,900 1290 .92 1.00 1.00 500 13,100 1070 .90 1.00 1.00 12,500 1150 .92 1.00 1.00 11,900 1240 .95 1.00 1.00 11 300 1310 .99 1.00 1.00 350 13,000 1070 .61 .73 .84 12.400 1150 .62 .75 .86 11,700 1230 .64 .77 .89 11,000 1300 .65 .79 .92 67 425 13,400 1080 .65 .78 .91 12,800 1160 .66 .80 .94 12,100 1240.68 .83 .97 11,300 1310 .70 .86 1.00 500 13,700 1080 .68 .83 .97 13,000 1170 .70 .86 1.00 12 300 1250 .72 .89 1.00 11,600 1320 .74 .92 1.00 350 14 100 1090 .46 .57 .67 13,400 1180 .46 .58 .69 12,600 1260 .47 t9 .71 11 900 1330 .48 1 .60 1 .73 71 425 14,500 1 1100 .47.60 .72 13 700 1190 .48 .61 .74 12 900 1270 .49 .63 .77 12,100 1340 .50 .65 .79 500 14 700 1100 .49 .63 .77 13 900 1190 .50 .65 .79 13 100 1270 .51 .67 .82 12 300 1350 1 .52 .69 .85 NOTE - All values are gross capacities and do not include evaporator coil blower motor heat deduction. - 27d - RATINGS ) NOTE - To determine sensible capacity, leaving wet bulb and dry bulb temperatures not shown in the tables, see Miscellaneous Engineering Data section, Page 9. HS18-511-513 WITH CH16-65V EVAPORATOR UNIT NOTE - All values are gross capacities and do not include evaporator coil blower motor heat deduction. HS18-511-513 WITH CB15-1200/65 EVAPORATOR UNIT Outdoor Air Temperature Entering Condenser Coil (°F) Enter. 85 85 85 95 95 95 1 105 105 115 115 Enter. Total Enter. Total Sensible Total Sensible Sensible Sensible Total Sensible Sensible Sensible Total Sensible Sensible Sensible Sensible Air Wet Air Total Comp. To Total Total Comp. To Total Total Comp. To Total Total Comp. To Total Bulb Vol. Cool Motor To Total Cool Motor To Total Cool Motor To Total Cool Motor To Total (°F) (cfm) Ca p' Watts Ratio (S/T)' Ca p' Watts Ratio (S/T) Ca p' Watts Ratio (S/T) Ca p' Watts Ratio (S/T) o) Dr Bulb (OF) Input (Btuh) Input D Bulb (°F) (Btuh) Input D Bulb °F IBtuh) Input D Bulb °F (Btuh) Input D Bulb (°F) 76 1 80 84 76 80 84 84 80 1 84 76 80 84 80 84 80 84 76 80 84 76 80 84 76 80 1 84 76 80 84 80 1 84 1500 52,000 4270 .78 .90 1.00 149.100 4610 .80 .93 11.00 146,100 4910 .83 .96 1.00 42,800 5160 .86 1.00 1.00 63 180053,800 1800 4330 .83 .97 1.00 50,600 4670 .86 1.00 11.00 147,800 5000 .89 1.00 1.00 45 000 5290 .93 1.00 1.00 1.00 1.00 2100 55.400 1 4400 .89 1.00 1.00 52,600 4760 .92 1.00 1.00 49 700 5090 .95 1.00 1.00 46.700 5380 .99 1.00 1.00 11.00 1.00 1500 55,600 4400 .61 .72 .84 52.400 4750 .62 .74 .86 149,000 5060 .64 .77 .90 145,600 5320 .66 .80 .93 67 1800 57 100 4450 .64 .77 .90 53 700 4800 .66 .80 .93 50,200 5120 .68 .83 .97 46,700 5380 .70 .86 1.00 .86 1.00 2100 58.200 4490 .68 .82 .97 54,700 4840 .70 .85 1.00 51 100 5160 .72 .89 1.00 47,500 5430 .75 .93 1.00 .92 1.00 1500 59.500 4540 .46 .56 .67 56,100 4900 .46 .58 .69 152,400 5220 .47 .59 .71 48,800 5500 .48 .61 .74 71 1800 60,900 4590 .47 .60 .72 57,300 4950 .48 .61 .74 53,500 5270 .49 .63 .77 49,700 5550 .50 .65 .80 .50 2100 61.900 4620 .49 .63 .77 58.200 4980 .50 .65 .79 54.300 5310 1 .51 1 .67 .83 50,400 1 5580 .52 .69 .86 NOTE - All values are gross capacities and do not include evaporator coil blower motor heat deduction. HS18-511-513 WITH CB15-1200/65 EVAPORATOR UNIT NOTE - All values are gross capacities and do not include evaporator coil blower motor heat deduction. HS18-511-513 WITH C14-65 EVAPORATOR UNIT Outdoor Air Temperature Enterinq Condenser Coil (°F) Enter. 85 85 95 95 105 105 115 115 Enter. Total Enter. Total Sensible Total Sensible Sensible Sensible Total Sensible Sensible Sensible Total Sensible Sensible Sensible Sensible Air Wet Air Total Comp. To Total Total Comp. To Total Total Comp. To Total Total Comp. To Total Bulb Vol. Cool Motor Ratio (S/T) Cool Motor Ratio IS/ Cool Motor Ratio (S/T°) Cool Motor Ratio (S/ (°F) (cfm) Cap. Watts D Bulb (F) Cap. Watts o D Bulb F Cap. Watts D Bulb (OF) Cap. Watts o) Dr Bulb (OF) Input D (Btuh) Input Input Dr (Btuh) Input Input Dr IBtuhl Input Input IBtuh1 Input 80 84 76 1 80 84 76 84 80 1 84 .75 76 80 84 80 84 .76 76 80 84 76 80 1 84 5890 76 80 1 84 4310 1500 51 800 14270 49,900 .78 .90 1.001 48,900 4600 .80 .93 1.00 45,900 4900 .83 .96 1.001 42,700 5150 .86 1.00 1.00 63 1800 53,5W 4320 .83 .97 1.001 50,100 1 4660 .86 1.00 1.00 47,500 4980 .89 1.00 1.0011 44,700 5270 .92 1.00 1.00 4430 2100 54,8W 1 4380 .88 1.00 1.001 52,100 4730 .91 1.00 1.001 49.200 5070 .94 1.00 1.00 46,200 5350 .99 11.00 1.00 4440 1500 55 500 1 4400 .61 .72 .84 52,200 4740 .62 .74 .86 1 48.900 5050 .64 .77 .90 45,500 5310 .66 .80 .93 67 1800 56 800 1 4440 .64 .77 .90 53 400 4790 .66 .80 .93 150-000 5100 .68 .83 .97 46,500 5370 .70 .86 1.00 59.000 14520 2100 57,800 1 4480 .67 .82 .96 54,300 4830 .69 .85 .99 1 50.800 5140 .71 .88 1.00 47,200 5410 .74 .92 1.00 4570 1 150011 59,400 1 4540 1 .46 .56 .67 55,900 4890 1 .46 1 .58 1 .6911 52,400 5220 .47 S.59 .71 48,700 5490 .48 .61 .74 71 1800 60,700 4580 .47 .59 .72 57 100 4940 .48 .61 .74 53,400 5260 .49 .63 .77 49 600 5540 .50 .65 .80 .49 2100 61 600 4610 .49 .62 .76 57 900 4970 .50 .64 .79 54.100 5300 .51 .66 .82 50 200 5570 .52 NOTE - All values are gross capacities and do not include evaporator coil blower motor heat deduction. HS18-511-513 WITH C14-65 EVAPORATOR UNIT NOTE - All values are gross capacities and do not include evaporator coil blower motor heat deduction. HS18-651-653 WITH CH16-51FF EVAPORATOR UNIT Outdoor Air Temperature Entering Condenser Coil (°F) Enter. 85 8595 95 105 105 115 Enter. Total Wet Sensible Total Comp. Sensible Sensible Total Comp. Sensible Sensible Total Comp. Sensible Sensible Wet Air Total Comp. Vol. Cool Total Comp. Total Cool Total Comp. Total Cool Total Comp. Total Bulb Vol. Cool Motor To Total Cool Motor To Total Cool Motor To Total Cool Motor To Total (°F) (cfm) Ca Cap. Watts Ratio Ca p' Watts Ratio IS/T) Ca p' Watts Ratio (S/T) Ca p' Watts Ratio (S/T) Dr Bulb (°F) IBtuh) Input D Bulb Bullb °F) ( (Btuh) Input Dr Bulb °F (Btuh) Input Dr Bulb °F (Btuh) Input Dry Bulb (°F 76 80 84 76 1 80 84 1500 76 80 1 84 .75 .85 .96 76 80 84 .76 .87 .98 76 80 1 84 5890 1500 53,000 4310 .79 .91 1.00 49,900 4640 .81 .94 1.00 46,900 4950 .84 .97 1.00 43,700 5210 .87 1.00 1.00 63 1800 54,800 4370 .84 .98 1.001 51,600 4710 .87 1.00 1.00 48,800 5050 .90 1.00 1.00.1 45,800 5330 .94 1.00 1.00 .97 1.00 2100 56 500 4430 .90 1.00 1.001 53 600 4800 .93 1.00 1.00 50.600 5130 .97 1.00 1.00 47,500 5420 1.00 1.00 1.00 .60 1500 56 600 1 4440 .61 .73 .84 53 200 4780 .63 .75 .87 49,800 5100 .64 .78 .90 46,300 5360 .66 .81 .94 67 1800 58,000 4480 .65 .78 .91 54 500 4830 .67 .81 .95 51,000 5150 .69 .84 .98 47,300 5420 .71 .88 1.00 1 59,100. 2100 59.000 14520 .69 .84 .98 55 500 4870 .71 .87 1.00 51,800 5190 .73 1 .90 1.00 48,200 5460 .76 .94 1.00 .45 1500 60,500 1 4570 1 .46 1 .57 .68 56,900 1 4930 .46 .58 1 .70 53.200 5260 .47 .60 .72 49,400 5530 .48 .62 .75 71 1800 61,800 1 4620 1 .48 1 .60 .73 58,100 1 4980 1 .48 1 .62 1 .7511 54.200 1 5300 .49 .64 .78 50 300 5580 .50 .66 .81 66,400 1 2100 62 700 1 4650 .49 .64 .78 58 900' 5010 .50 .66 .81 54.900 5340 .51 .68 .84 51 000 5610 .53 .71 1 .88 NOTE - All values are gross capacities and do not include evaporator coil blower motor heat deduction. HS18-651-653 WITH CH16-51FF EVAPORATOR UNIT NOTE - All values are gross capacities and do not include evaporator coil blower motor heat deduction. Outdoor Air Temperature Enterinq Condenser Coil (°F) Enter. 8595 105 115 Wet Total Air Total Comp. Sensible Total Comp. Sensible Total Comp. Sensible Total Comp. Sensible Bulb Vol. Cool Motor To Total Cool Motor To Total Cool Motor To Total Cool Motor To Total (°F) (cfm) Cap. Watts Ratio IS/T) Ca p' Watts Ratio IS/TI Ca p' Watts Ratio IS/TI Cap. p Watts Ratio (S/T) (Btuh) Input Dr Bulb (°F) (Btuh) Input Dr Bulb (°F) (Btuh) Input Dr Bulb (°F) (Btuh) Input Dr Bulb (°F) 76 84 76 84 76 80 84 76 80 84 1500 55,700U5490 .75 .85 .96 53,000 5550 .76 .87 .98 50,400 5890 .78 .90 1.00 47,900 6220 .80 .92 1.00. 63 1750 57,300.78 .90 1.00 54,500 5640 .80 .93 1.00 51,800 5990 .82 .95 1.00 49,300 6320 .84 .98 1.00 2000 58,600.82- .95 1.00 55 900 5720 .84 .97 1.00 52.900 6060 .86 1.00 1.00 50 600 6420 .89 1.00 1.00 1500 59,700.59 .69 .79 56,800 5780 .60 .71 .81 53,900 6130 .61 .72 .83 51.200 6460 .62 .74 .86 67 1750 61,100.61 .73 .84 58 100 5850 .62 .74 .86 55 200 6210 .63 .76 .88 52 300 6540 .65 .78 .91 200062 200.63 .76 .88 1 59,100. 5910 .65 .78 .91 56.100 1 6270 .66 '.80 .94 53.200 6600 .68 .82 .97 150011 63,900. ( 5640 .45 .54 .64 1 60,900 "6010 .45 1 .55 .65 57,900 6380 .46 1 .56 .67 55 000 6720 .46 .57 .68 71 1750 65 300 5710 .46 .57 .67 62 200 6090 .46 .58 .69 59 100 6450 .47 .59 .71 56,000 6780 .47 .60 .73 2000 11 66,400 1 5760 .47 .59 .71 1 63,100 6140 .47 .60 .72 59,900 6500 .48 .61 1 .74 jj 56,800 6840 .49 .63 .77 NOTE - All values are gross capacities and do not include evaporator coil blower motor heat deduction.