Loading...
14-0404 (SOL) Solar PlansVICINITY MAP Riverside County: APN #600051001-5 CONSTRUCTION HOURS: OCTOBER 1 THRU APRIL 30 Monday - Friday 7:00 am - 5:30 pm Saturday 8:00 am - 5:00 pm Sunday NOT ALLOWED Government Code Holidays NOT ALLOWED MAY 1 THRU SEPTEMBER 30 Monday - Friday 6:00 am - 7:30 pm Saturday 8:00 am - 5:00 pm Sunday NOT ALLOWED Government Code `Holidays NOT ALLOWED •-% PROJECT CONTACTS: CONTRACTOR:RENOVA Lea Waki: lea@renovasolar.com Isaac Gamez: isaac@renovasolar.com SCOPE OF WORK: APPLICABLE CODES: Calilfornia Residential Code 2013 California Electrical Code 2013 National Electrical Code 2011 2012 California Amendments SHEETINDEX GENERAL C1 Cover Sheet S1 Site Plan S2 Plot Plan ELECTRICAL E1 Marking/Panel Schedule E2 Single Line STRUCTURAL P1 Profile Elevations DATA SHEET w�N Module Inverter C Load Calculation Wind Calculation Ana Unirac Racking Disconnect Project consist of installing: conduits w/fittings and wires; roof stanchions for rack mounting system to support the photo voltaic (PV) modules; power inverters to provide a renewable power source for the customer; and upgrade the existing main service panel.' M N O O 00 LO W J } J z i3 (D CL Drawn I 0 fY W 0 U) W W itO 2 L0 M 00 ti N N 0) Q U Z Date Drawn: 03/31/2014 Revision No. 0 Sheet No. • C.1 v � pNNQ vp 0 w�N C o? E Ana M N O O 00 LO W J } J z i3 (D CL Drawn I 0 fY W 0 U) W W itO 2 L0 M 00 ti N N 0) Q U Z Date Drawn: 03/31/2014 Revision No. 0 Sheet No. • C.1 ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 CALIFORNIA RESIDENTIAL, 2013 ELECT RICA TIONAL ELECTRICAL CODE. HORSESH OE RD EXISTING METER # AK164-3606 PROPOSED BI-DIRECTIONAL METER EXISTING 200A MAIN SERVICE PANEL AIC RATING 10,000 AMPERES 120/240 VOLT, 1 0, 3W ¢� LOCATED ON WEST EXTERIOR WALL > 60 AMP AC DISCONNECT SQUARE -D #DU222RB CL 120/240 VOLT LOCATED NEXT TO MAIN PANEL 60 AMP AC DISCONNECT SQUARE -D #DU222RB 120/240 VOLT LOCATED IN GARAGE FRONIUS 10000 WATT INVERTER FRONIUS IG PLUS ADVANCE 10.0-1 120/240 VOLT – LOCATED IN GARAGE SOLAR MODULES CITY OF LA QUINTA BUILDING & SAFETY DEPT. AP®QED FOR CONSTRUCTION DATE BY—*— - STRING #1 - STRING #2 - STRING #3 - STRING #4 POOL SOLAR SYSTEM SIZE: 10.464 kW DC CEC AC SYSTEM SIZE: 9.211 kW AC NOTES: 1. THIS IS A 10.464 KW SOLAR ELECTRIC SYSTEM USING (32) SUNPOWER SPR-327NE-WHT-D (327 WATT) PHOTOVOLTAIC MODULES. 2. THIS SYSTEM IS GRID-INTERTIED VIA UL -LISTED POWER CONDITIONING INVERTER: (1) FRONIUS IG PLUS ADVANCED 10.0-1 3. THIS SYSTEM HAS NO UPS, NO BATTERIES. 4. THIS IS A ROOF MOUNTED SYSTEM, ADDING 2.68 LB/SQ FT. FOLLOWING THE ROOF SLOPE. ROOF IS SPANISH TILE AT 17° PITCH (AVG 17°). , 5. THE SYSTEMS SQUARE FOOTAGE IS 580 FT' (16% OF TOTAL ROOF AREA). THE MODULES AZIMUTH IS 196°(AVG 196°). 6. MODULES ARE 0 DEGREES TILT ABOVE ROOF SLOPE, NOT TO EXCEED 18" . ABOVE ROOF SURFACE. 7. BUILDING IS A SINGLE STORY DWELLING. 8. LAG SCREWS ARE 3/8" X 4" AT 48" O.C. MAX, WITH 2.5" INTO FRAMING. 9. MODULES WILL BE SECURED TO ROOFTOP USING UNIRAC STANDOFF ATTACHMENTS. 10. ATTACHMENTS WILL BE DOUBLE -FLASHED. 11. DESIGNED FOR BASIC WIND SPEED OF 110 MPH PER UNIRAC CALCULATIONS, SEE SPECS. �HIMN / I12. VISIBLE DIMOENSIONS ARE SHALL L6E4 PAINTED TO MATCH. 13. MODULE 14. SYSTEM INSTALLATION SHALL BE PER NEC 690 AND IS SUBJECT TO FIELD INSPECTION BY THE CITY. 15. PROPER CLEARANCES SHALL BE IN ACCORDANCE WITH ALL ADOPTED CAL FIRE GUIDELINES. PATIO COVER r N W E s SCALE: 1" - 20' c 0 ¢� k > c-" CL b U a�rnMb Q r� fJ a (D M Ccg W ND > 10 CE (D C CL c W U "4BCE� ■ AEURFF1ITEo = PV Installation Company Renova Energy Corp. California.- 2012 s '., t;nr.E:ecf f-nrrry Prartiticnars Drawn By: CESAR LOPEZ Date Drawn: 04/24/2014 Revision No. 1 Sheet No S.1 0 cM L0 W _ M �. O W U 00 U LI) W Q J = Z U-)cy J M ui 00 0) � J z U N 2 a Drawn By: CESAR LOPEZ Date Drawn: 04/24/2014 Revision No. 1 Sheet No S.1 FWA 4 Al _._.p. ,s_ # ate- w .. _ k...�w, wt'7 - 4. ♦ _ r ^'k'C'^" ..n.�.,,,.. r s , •;i,sl f • - ■ renova. Renova Energy Corp 75-181 Mediterranean Ave. Palm Desert, CA 92260 (760)568-3413 1 :------ un4r%O'.)c ' WARNING: ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. OPERATING CURRENT: 23.9 Amps OPERATING VOLTAGE: 357.1 Volts MAXIMUM VOLTAGE: 550.3 Volts SHORT-CIRCUIT CURRENT: 25.8 Amps NOTE: MOUNT ON DC DISCONNECT OF FRONIUS INVERTER BACKGROUND "RED" AND "WHITE" LETTERING. J THIS PANEL IS FED BY TWO SOURCES: UTILITY AND SOLAR PHOTOVOLTAIC I A NOTE: MOUNT ON MAIN SERVICE PANEL COVER A WARNING: WARNING: ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. MAX AC OPERATING CURRENT: 41.7 Amps OPERATING AC VOLTAGE: 240 Volts NOTE: MOUNT ON AC DISCONNECT THIS FACILITY IS EQUIPPED WITH A PHOTOVOLTAIC GENERATOR LOCATED ON THE ROOF AS SHOWN. THE SYSTEM MAY BE DISCONNECTED FROM THE FACILITY PER THE AC DISCONNECT AS SHOWN. SITE PLAN 200A MAIN PANEL 60 AMP AC DISCONNECT (INSIDE GARA, FRONIUS 10000W INVER (INSIDE GARAI 60 AMP AC DISCONNECT (NEXT TO PAN 0 NOTE: MOUNT ON SERVICE PANEL *ALL PLACARDS SHALL BE RED WITH WHITE LETTERING PROJECT SIGNAGE SCALE: N/A 0 3" WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. NOTE: MOUNT ON MAIN SERVICE PANEL AT SOLAR BREAKER 3" - PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATIONS NOTE: MOUNT ON DISCONNECTS 3" THE MAIN BREAKER HAS BEEN DOWN -SIZED TO 175 AMPS NO UP-SIZING IS PERMITTED, NOTE: MOUNT NEXT TO MAIN BREAKER SAFEGUARDS * SOLAR BREAKER SHALL BE LISTED FOR USE IN EXISTING MAIN PANEL. ACCEPTED BREAKER REPLACEMENTS ARE EATON, SQUARE -D & GE. * ALL JUNCTION BOXES SHALL BE NEMA OUTDOOR/RAINTIGHT RATED. * WILEY CABLE CLIPS SHALL BE USED. ' ALL EMT SHALL USE OUTDOOR RAINTIGHT COMPRESSION FITTINGS. * SERIES SOLAR CIRCUITS SHALL BE FUSED AT 15 AMPS DC. *ALL EQUIPMENT SHALL BE LABELED. * ADD COMBINER / JUNCTION BOXES AS NEEDED. *AN INTERNAL BLOCKING DIODE IS PROVIDED IN EACH MODULE. *GROUND FAULT PROTECTION DEVICE IS INTERNALLY BUILT INTO SUNPOWER INVERTERS. *MODULE GROUNDING SHALL BE MADE WITH ILSCO GBL-4DB LUGS AND #8 SOLID BARE COPPER USING WEEB CONNECTIONS. *ALL NEUTRAL TO GROUND CONNECTIONS SHALL OCCUR IN THE MAIN PANEL. *EMT SHALL BE 1" MINIMUM. * JUNCTION BOX/ COMBINER BOX ENTRY SHALL USE COMPRESSION FITTINGS. MATERIALS (32) SUNPOWER 327 WATT PHOTOVOLTAIC MODULES #SPR-327NE-WHT-D (1) FRONIUS IG PLUS ADVANCED 10.0-1 - 9,995 W; 240 VOLT (2) SQUARE -D AC DISCONNECT, 60A NON -FUSIBLE, 2 -POLE #DU222RB SOLAR PRODUCTION SUMMARY GROSS NAMEPLATE RATING (32 x 327/1000) 10.464 kW CEC-AC SYSTEM SIZE 9.211 kW W _*_ E .S NOTES+ SOLAR PRODUCTION STATS.IIALE. 2 I P.V. PLAN J NAI=. 1 3" BACKGROUND CIRCUIT CODE: "RED"AND co WARNING: "WHITE' CL CN ELECTRIC SHOCK HAZARD LETTERING. C IF A GROUND FAULT IS INDICATED, THE t L: LONG -CONTINUOUS NORMALLY GROUNDED CONDUCTORS LOCATION: EXTERIOR WEST WALL MAYBE UNGROUNDED AND ENERGIZED. —� NOTE: MOUNT ON INVERTER THIS FACILITY IS EQUIPPED WITH A PHOTOVOLTAIC GENERATOR LOCATED ON THE ROOF AS SHOWN. THE SYSTEM MAY BE DISCONNECTED FROM THE FACILITY PER THE AC DISCONNECT AS SHOWN. SITE PLAN 200A MAIN PANEL 60 AMP AC DISCONNECT (INSIDE GARA, FRONIUS 10000W INVER (INSIDE GARAI 60 AMP AC DISCONNECT (NEXT TO PAN 0 NOTE: MOUNT ON SERVICE PANEL *ALL PLACARDS SHALL BE RED WITH WHITE LETTERING PROJECT SIGNAGE SCALE: N/A 0 3" WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. NOTE: MOUNT ON MAIN SERVICE PANEL AT SOLAR BREAKER 3" - PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATIONS NOTE: MOUNT ON DISCONNECTS 3" THE MAIN BREAKER HAS BEEN DOWN -SIZED TO 175 AMPS NO UP-SIZING IS PERMITTED, NOTE: MOUNT NEXT TO MAIN BREAKER SAFEGUARDS * SOLAR BREAKER SHALL BE LISTED FOR USE IN EXISTING MAIN PANEL. ACCEPTED BREAKER REPLACEMENTS ARE EATON, SQUARE -D & GE. * ALL JUNCTION BOXES SHALL BE NEMA OUTDOOR/RAINTIGHT RATED. * WILEY CABLE CLIPS SHALL BE USED. ' ALL EMT SHALL USE OUTDOOR RAINTIGHT COMPRESSION FITTINGS. * SERIES SOLAR CIRCUITS SHALL BE FUSED AT 15 AMPS DC. *ALL EQUIPMENT SHALL BE LABELED. * ADD COMBINER / JUNCTION BOXES AS NEEDED. *AN INTERNAL BLOCKING DIODE IS PROVIDED IN EACH MODULE. *GROUND FAULT PROTECTION DEVICE IS INTERNALLY BUILT INTO SUNPOWER INVERTERS. *MODULE GROUNDING SHALL BE MADE WITH ILSCO GBL-4DB LUGS AND #8 SOLID BARE COPPER USING WEEB CONNECTIONS. *ALL NEUTRAL TO GROUND CONNECTIONS SHALL OCCUR IN THE MAIN PANEL. *EMT SHALL BE 1" MINIMUM. * JUNCTION BOX/ COMBINER BOX ENTRY SHALL USE COMPRESSION FITTINGS. MATERIALS (32) SUNPOWER 327 WATT PHOTOVOLTAIC MODULES #SPR-327NE-WHT-D (1) FRONIUS IG PLUS ADVANCED 10.0-1 - 9,995 W; 240 VOLT (2) SQUARE -D AC DISCONNECT, 60A NON -FUSIBLE, 2 -POLE #DU222RB SOLAR PRODUCTION SUMMARY GROSS NAMEPLATE RATING (32 x 327/1000) 10.464 kW CEC-AC SYSTEM SIZE 9.211 kW W _*_ E .S NOTES+ SOLAR PRODUCTION STATS.IIALE. 2 I P.V. PLAN J NAI=. 1 MAIN PANEL SCHEDULE SCALE: A N/A `'F NOTES 1. THE PV SOURCE CIRCUIT IS POSITIVELY GROUNDED. SUPPORT SYSTEM 2. WIRE AND SIZES ARE AS INDICATED OR LARGER. * WIND LOAD: BASIC WIND SPEED (3 -SECOND GUST, 110 MPH) 3. ALL EQUIPMENT IS BONDED BY MECHANICAL MEANS OR BY A GROUNDING CONDUCTOR. * WIND EXPOSURE C, 4. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE #8 AWG COPPER GROUND WIRE * CONDUIT SUPPORT BY COOPER/BEELINE OR CADDY AND BONDED TO THE EXISTING GROUNDING ELECTRODE SYSTEM. * VISIBLE AND ACCESSIBLE 5. CHANGES TO DESIGN NEED PRIOR ENGINEER APPROVAL. * SOLARMOUNT RACKING SYSTEM, LAG BOLTED DIRECTLY INTO RAFTERS. MARKING *MARKING IS REQUIRED ON INTERIOR AND EXTERIOR DIRECT CURRECT (DC) CONDUIT, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES AND DISCONNECTS. (CRC R331.2) *THE MATERIAL USED FOR MARKING SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. MARKING AS REQUIRED IN SECTIONS R 331.2.2 THROUGH R331.2.4 SHALL HAVE LETTERS CAPITALIZED WITH A MINIMUM HEIGHT OF 3/8" WHITE ON RED BACKGROUND. (CRC R331.2.1) *THE MARKING CONTENT SHALL CONTAIN THE WORDS•"WARNING; PHOTOVOLTAIC POWER SOURCE" (CRC R331.2.2) *THE MAIN SERVICE MARKING SHALL BE PLACED ADJACENT TO THE MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM THE LOCATION WHERE THE DISCONNECT IS OPERATED. (CRC R311.2.3) *THE MARKING SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES EVERY 10 FEET, WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND • BELOW PENETRATIONS OF ROOF/CEILING AS$EMBLIF.S, WALLS OR BARRIERS. (CRC 8331.2.4) CITE' OF LA OUINTA BUILDING & SAFETY DEPT. 0 FOR CONSTRUCTION DATE BY C. 0 r CIRCUIT CODE: N: NON -CONTINUOUS co PANEL: MAIN PANELVOLTAGE: 240/120 1P,3W CL CN a �jmrnCl) C BUS: 200 A t L: LONG -CONTINUOUS a LOCATION: EXTERIOR WEST WALL CLm � �C)i (U a) W R: DEMANDABLE RECEPTACLES c MOUNTING: FLUSH Ln C c K: KITCHEN W AIC RATING: 10,000 � VA LOAD o TYPE C.B. BUS C.B. TYPE p VA LOAD U LOAD DESCRIPTION 0 00 M p LOAD DESCRIPTION A B L) N R L TR P A B TR P L R N 0 A B U 1 4997.5 Fronius IG Plus Advanced 10.0-1 L 60 60 2 x L Drawn By: 2 3 14997.5 Fronius IG Plus Advanced 10.0-1 L - - x L 04/24/2014 4 4997.514997.51 PHASE TOTALS 1 PHASE TOTALS PHASE TOTALS A+B CONNECTED VA (CODE N): TOTAL PHASE A: 4997.5 CONNECTED VA (CODE L): 9995 TOTAL PHASE B: 4997.5 CONNECTED VA (CODE R): CONNECTED VA (CODE K): TOTAL CONNECTED KVA: 9.995 DEMAND KVA ' EXISTING LOADS UNKNOWN TOTAL ADJUSTED KVA: 9.995 TOTAL PANEL AMPS: 41.7 AMPS W/L CL: 41.7 MAIN PANEL SCHEDULE SCALE: A N/A `'F NOTES 1. THE PV SOURCE CIRCUIT IS POSITIVELY GROUNDED. SUPPORT SYSTEM 2. WIRE AND SIZES ARE AS INDICATED OR LARGER. * WIND LOAD: BASIC WIND SPEED (3 -SECOND GUST, 110 MPH) 3. ALL EQUIPMENT IS BONDED BY MECHANICAL MEANS OR BY A GROUNDING CONDUCTOR. * WIND EXPOSURE C, 4. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE #8 AWG COPPER GROUND WIRE * CONDUIT SUPPORT BY COOPER/BEELINE OR CADDY AND BONDED TO THE EXISTING GROUNDING ELECTRODE SYSTEM. * VISIBLE AND ACCESSIBLE 5. CHANGES TO DESIGN NEED PRIOR ENGINEER APPROVAL. * SOLARMOUNT RACKING SYSTEM, LAG BOLTED DIRECTLY INTO RAFTERS. MARKING *MARKING IS REQUIRED ON INTERIOR AND EXTERIOR DIRECT CURRECT (DC) CONDUIT, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES AND DISCONNECTS. (CRC R331.2) *THE MATERIAL USED FOR MARKING SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. MARKING AS REQUIRED IN SECTIONS R 331.2.2 THROUGH R331.2.4 SHALL HAVE LETTERS CAPITALIZED WITH A MINIMUM HEIGHT OF 3/8" WHITE ON RED BACKGROUND. (CRC R331.2.1) *THE MARKING CONTENT SHALL CONTAIN THE WORDS•"WARNING; PHOTOVOLTAIC POWER SOURCE" (CRC R331.2.2) *THE MAIN SERVICE MARKING SHALL BE PLACED ADJACENT TO THE MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM THE LOCATION WHERE THE DISCONNECT IS OPERATED. (CRC R311.2.3) *THE MARKING SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES EVERY 10 FEET, WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND • BELOW PENETRATIONS OF ROOF/CEILING AS$EMBLIF.S, WALLS OR BARRIERS. (CRC 8331.2.4) CITE' OF LA OUINTA BUILDING & SAFETY DEPT. 0 FOR CONSTRUCTION DATE BY C. 0 r co N W CL CN a �jmrnCl) C 0 rnmL c t _C0 a C� CLm � �C)i (U a) W 0 c� E c 0_ Ln C c F NABCEP C[ltN:��l1!l�01 PV Installation Company Renova Energy Corp. California - 2012 Crr Fea Enerry Pnrtrticnere: Sheet No EA 0 co W Ln M O 07 O W U 00 C/) Ln W Q W � Z Li) J M C E 00 M Q z J U a� .a a Drawn By: CESAR LOPEZ Date Drawn: 04/24/2014 Revision No. 1 Sheet No EA c� • -� TO IID Solar System Size: 10.464 kW DC MAIN PANEL EXISTING 200 AMP MAIN SERVICE PANEL fu 70 SOLAR ARRAY CEC System Size: 9.211 kW AC AIC RATING 10,000 AMPERES 240/120 VOLT, 2 -POLE > 00 o > (32) SUNPOWER 327 WATT NUMBER OF WIRES: (3) THREE LOCATED ON WEST EXTERIOR WALL acN PHOTOVOLTAIC MODULES SINGLE PHASE Qo #SPR-327NE-WHT-D METER # AK1 B4-3606 I 0-2 a A' MODULE PTC RATING: 301.4W (2) #2 THWN-2 PROPOSED BI-DIRECTIONAL a) °' d v oo" 0 U (4 STRINGS OF 8 MODULES) (1) #2 THWN-2 NEUTRAL METER # DC DISCONNECT 1 #8 THWN-2 EGC w.= `° O a) SIJ Q co FUSED AT 15 AMPS FRONIUS IG PLUS �1� #8 THWN-2 GEC DOWNSIZE EXISTING 2 0AC > m (D L > o n o `" AVANCED 10.0-1 1 1/4" EMT MAIN BREAKER TO 175 �� o INVERTER ��a o 240 V, 2P 20 AMP SOLA U BREAKER) BREAKER NBAR 60 AMP NON -FUSIBLE 60 AMP NON -FUSIBLE G BAR LOCATED IN AC DISCONNECT AC DISCONNECT -- GARAGE SQUARE -D #DU222RB SQUARE -D #DU222RB ALOCATED PV Installation Company 240V, 2P 240V, 2P IN GARAGE LOCATED NEXT TO PANELWU GEC 8) #8 THWN-2 - GEC Renova Energy Corp. camornia - 2012 1) #8 THWN-2 EGC GROUND 1/4" EMT (2) #2 THWN-2 TO 60 AMP 2 -POLE SOLAR BREAKER *ALL WIRING BETWEEN MODULES SHALL BE TYPE USE -2 OR PV -WIRE IF EXPOSED. NOM Ammkm, Boan7 of (1) #2 THWN-2 NEUTRAL-/NABCEP ALL CONDUIT SHALL BE 1" EMT OR LARGER. D ALL CONDUIT SHALL BE BONDED. 1 #8 THWN-2 EGC ALL CONDUIT SHALL BE SUPPORTED BY RUBBER PYRAMID SUPPORTS. �1; #8 THWN-2 GEC (CONNECTED TO GND) EMT ENTRY TO MAIN STEEL CITY 6"X6"X4" (OR LARGER) OUTDOOR JUNCTION BOXES SHALL BE USED AS NEEDED. *TO BE DETERMINED INAFIELD MONITOR/ PV SUPERVISOR ALL CONDUIT SHALL HAVE PLASTIC STRAIN RELIEF CONNECTORS TO PROTECT WIRES. INTERNET 120 VOLT SINGLE LINE DIAGRAM SCALE: N/A M DC CIRCUITS AC CIRCUITS O LO M LO = 0) MODULES TO FRONIUS 1000OW INVERTER FRONIUS 1000OW INVERTER TO MAIN PANEL N p U) Q 4 STRINGS X 8 MODULES = 32 MODULES O LU (� / = 25[PER NEC 215 1 AMPS (60 AMP SOLAR BREAKER) 65A X 1. . . MAX VOLTAGE DC = (MODULE Voc + ((25°C -Temp Record Low°C [via www.solarabcs.org]) x T coefV)) X #modules in series 9995W 240 VOLT 41. = 52 002(A)1] � MAX VOLTAGE DC= (64.9 +((25°C - 3°C) x .1766)) X 8 modules in series = 550.3 VOLTS AC CONDUIT SHALL BE MOUNTED 1/2" TO 3 1/2" ABOVE ROOFTOP SURFACE. � Q O F- 6.46 AMPS EACH CIRCUIT X 1.56[PER NEC 690.8] = 10.1 AMPS ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR & 44°C AMBIENT TEMP. PER SOLARABCS.ORG 6.46 LU J = Z_ FUSED AT 15 AMPS EACH CIRCUIT LOCATED AT INVERTER #2 WIRE = 130 AMPS X .58[PER NEC TABLE 310.15(B)(16) & PER NEC TABLE 690.31(C)] = 75.4 AMPSJ U-) Cf) Cy DC CONDUIT SHALL BE MOUNTED 1/2" TO 3 1/2" ABOVE ROOFTOP SURFACE. 75.4 AMPS X 1.0[CONDUIT FILL PER NEC TABLE 310.15(B)(3)(a)] = 75.4 AMPS > 60 AMPS = OK 00 ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR & 44°C AMBIENT TEMP. PER SOLARABCS.ORG (3) #2 THWN-2 AWG WIRE, (2) #8 THWN-2 GROUND ca #8 WIRE = 55 AMPS X .58[PER NEC TABLE 310.15(B)(16) & PER NEC TABLE 690.31(C)] = 31.9 AMPS 1 1/4" EMT @ 40% FILL PER NEC TABLE C.1 = (5) #2 THWN-2 WIRES = OK ) 0 31.9 AMPS X .70[CONDUIT FILL PER NEC TABLE 310.15(B)(3)(a)] = 22.3 AMPS > 15 AMPS = OK ` CITY OF LA QUI NTA 4 STRINGS= (8) #8 THWN-2 AWG WIRE, (1) #8 THWN-2 GROUND raven By: 1 1/4" EMT @ 40% FILL PER NEC TABLE C.1 = (16) #8 THWN-2 WIRES = OK BUILDING & SAFETY DEPT. CESAR LOPEZ MAIN PANEL BACKFEED CALCULATION APPRODOWNSIZE ate Drawn: EXISTING 200 AMP MAIN SERVICE PANEL EXISTING 200 AMP MAIN BREAKER TO 175 AMP FOR CONSTRUCTION 03/31/2014 evision No. 120% OF 200 AMP BUSS: ALLOWABLE BACKFED AMPS [PER NEC 705.12(D)(2)] = 240 AMPS 240 AMP - 175 AMP MAIN BREAKER= 65 TOTAL AMP ALLOWABLE DATE BY 60 AMP SOLAR BREAKER <_ 65 AMPS = OK 0 ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 CALIFORNIA RESIDENTIAL, sheet No. 2013 ELECTRICAL CODE BASED ON THE 2011 NATIONAL ELECTRICAL CODE. CALCULATIONS SCALE: 2 E.2 - - - N/A. - T.OP.VIEW AODULES NOT TO EXCEED 18" ABOVE ROOF SURFACE } ELEVATION A -A' t I a�Y�/•J i DULES NOT TO EXCEED 18" ABOVE ROOF SURFACE ELEVATION 6-6' *MODULES NOT TO EXCEED 18" ABOVE ROOF SURFACE ru ai a >o a o cN b jIU C4: rrn�Ue'� c ai m r co W y y C. o;0(0 E (Dm '_Lr) d c c c: /G G D . Pd IflSwrw�rrrer tallation Company Regova Energy corp. California,- 2072 1� NOAh"Arrie+iccan Board of. I SCALE: 1 "=3' � M W _ MO C, O (n Q c) W U `n of Q J O .z � J Cr) CY M E 1- J Z. � U N O • d Drawn By: CESAR LOPEZ Date Drawn: 04/24/2014 Revision No: • 1 Sheet No. _ P. 1 SCALE: Z 20% EFFICIENCY ! SunPower E20 panels are the highest i efficiency panels on the market today, l providing more power in the some r 1 amount of space L t MAXIMUM SYSTEM OUTPUT Comprehensive inverter compatibility ensures that customers can pair the highest - efficiency panels with the highest -efficiency inverters, maximizing system output REDUCED INSTALLATION COST More power per panel means fewer panels r per install. This saves both time and money. i� RELIABLE AND ROBUST DESIGN SunPower's unique Maxeon'"cell, technology and advanced module design,ensure industry-leading reliability MAXEONTM CELL TECHNOLOGY Patented all -back -contact solar cell, providing the industry's highest efficiency and reliability E 0 SERIES THE WORLD'S STANDARD FOR SOLAR'' SunPower' E20 Solar Pcnels provide today's highest efficiency and performance. Powered b -v SunPower Maxeon'' cell technology, the E20 series provides panel corversion efficiencies of up to 20.1 %. The E20's low voltage temperature coefficient, anti -reflective glass and exceptional low -light performance attributes provide outstanding energy delivery per peak power watt. SUNPOWER'S HIGH EFFICIENCY ADVANTAGE 20% 15% 10% 5% SERIES SERIES SERIES aunpowercorp.com C UL US MODEL: SPR-327NE-WHT-D ELECTRICAL DATA Measured at Standard Test Conditions MCI: irradiance of 1000W/ms, AM 1.5, and ceR temperature 25° C Peak Power (+5/-3%) Pmax 327 W Cell Efficiency n 22.5% Panel Efficiency n 20.1 % Rated Voltage Vmpp 54.7 V Rated Current Impp 5.98 A Open Circuit Voltage Voc 64.9 V Short Circuit Current • Isc 6.46 A Maximum System Voltage UL 600 V Temperature Coefficients Power (P) - 0.38%/K Voltage (Voc) -176.6mV/K Current (Isc) 3.5mA/K NOCT 45' C +/- 2' C Series Fuse Rating 20 A Grounding Positive grounding not required IN CURVE 7 F-1 OW-W/m' c f 50e C 6 �000 w%m' - I � 5 - - a 4 800w/ - `c t 3 i — lJ 2 500 W/m' I 0 200W/1 0 10 20 30 40 50 60 70 Voltage M Curren)/volloge characteristics with dependence on irradiance and module temperature. TESTED OPERATING CONDITIONS Temperature - 40' F to +185' F (- 40' C to + BY C) Max load 113 psf 550 kg/m2 (5400 Pa), front (e.g. snow) w/specified mounting configurations 50 psf 245 kg/m2 (2400 Pa) front and back (e.g. wind) Impact Resistance Hail: (25 mm) at 51 mph (23 m/s) WARRANTIES AND CERTIFICATIONS Warranties 25 -year limited power warranty 10 -year limited product warranty Certifications Tested to UL 1703. Class C Fire Rating DIMENSIONS 2X 11.0 (.431 MM (A) - MOUNTING HOLES (8) - GROUNDING HOLES �[ 1 181 2x 577 (22.70] 180[7.071 (IN) 12X 06.6 (.261 1 O 04.2 [.171 322 [ 12.691 4X230.8[ -?.091 lel m I o< IIB � I d 801H 2 - ENDS I r S r I - I 1559[61.39] 46[1.811 �— (A) 915[36.02] 1200[47.241 12(.47]7 1535[60.45] Please read safety and installation instructions before using this product, visit sunpowercorp.com for more details. ' 0 2011 SunPower Corporation. SUNPOWER, the SunPower logo, and THE WORLD'S STANDARD FOR SOLAR, and MAxEON are trademarks or mgbtemd trodemorb s u n p o we rc o r p . c o m of SunPo ver Corporation in the US and a8ror countries as web. All Rights Reserved. Specifications included in this datasheet am subject to change without notice. Document 21001.65484 Rev B / LTR EN CS 11 316 MECHANICAL DATA Solar Cells 96 SunPower MoxeonT' cells Front Glass High -transmission tempered glass with anti -reflective AR coating Junction Box IP -65 rated with 3 bypass diodes Dimensions: 32 x 155 x 128 mm Output Cables 1000 mm cables / Multi -Contact (MC4) connectors Frame Anodized aluminum alloy type 6063 (black) Weight 41.0 lbs (18.6 kg) IN CURVE 7 F-1 OW-W/m' c f 50e C 6 �000 w%m' - I � 5 - - a 4 800w/ - `c t 3 i — lJ 2 500 W/m' I 0 200W/1 0 10 20 30 40 50 60 70 Voltage M Curren)/volloge characteristics with dependence on irradiance and module temperature. TESTED OPERATING CONDITIONS Temperature - 40' F to +185' F (- 40' C to + BY C) Max load 113 psf 550 kg/m2 (5400 Pa), front (e.g. snow) w/specified mounting configurations 50 psf 245 kg/m2 (2400 Pa) front and back (e.g. wind) Impact Resistance Hail: (25 mm) at 51 mph (23 m/s) WARRANTIES AND CERTIFICATIONS Warranties 25 -year limited power warranty 10 -year limited product warranty Certifications Tested to UL 1703. Class C Fire Rating DIMENSIONS 2X 11.0 (.431 MM (A) - MOUNTING HOLES (8) - GROUNDING HOLES �[ 1 181 2x 577 (22.70] 180[7.071 (IN) 12X 06.6 (.261 1 O 04.2 [.171 322 [ 12.691 4X230.8[ -?.091 lel m I o< IIB � I d 801H 2 - ENDS I r S r I - I 1559[61.39] 46[1.811 �— (A) 915[36.02] 1200[47.241 12(.47]7 1535[60.45] Please read safety and installation instructions before using this product, visit sunpowercorp.com for more details. ' 0 2011 SunPower Corporation. SUNPOWER, the SunPower logo, and THE WORLD'S STANDARD FOR SOLAR, and MAxEON are trademarks or mgbtemd trodemorb s u n p o we rc o r p . c o m of SunPo ver Corporation in the US and a8ror countries as web. All Rights Reserved. Specifications included in this datasheet am subject to change without notice. Document 21001.65484 Rev B / LTR EN CS 11 316 e•) / Battery Charging Systems / Welding Technology / Solar Electronics i SHIFTING THE LIMITS FRONIUS IG PLUS ADVANCED INVERTER WITH INTEGRATED AFCI r -,1 I INON 1 -__-- / MIXTM Technology / Smart Transformer / WLAN / Quick Service / Smart Grid Switching Technology Ready / The Fronius IG Plus Advanced is the first complete inverter lineup of the NEC 2011 compliant AFCI protected inverters in the United States. Power classes ranging from 3 to 12 kW in both single and true 3 phase applications with integrated Fronius MIX Technology and wide voltage windows are the perfect match for your system design. TECHNICAL DATA: FRONIUS IG PLUS ADVANCED (3.0-1uN1 3.8-1 UNI, 5.0-1 DN16.0-1 UNI, 7.5-1 UNI) ---moi. INPUT DATA 3.0-10x1 3.8-1ux, 5.0.1,,x1 6.0 -lux[ 7.5 111x, Recommended PV -Power (kWp) 2.50-3.45 3.20-4.40 4.25-5.75 5.10 - 6.90 6.35-8.60 i Nominal Input Curr.-nt _ l b. i •1 10.5 A 13,S A _ 165 A 20.7 A Max. Usable Input Current 14.0 A 17.6 A 23.4 A 28.1 A 35.1 A MPH - Voltir., Rang,, 96.0% 96.0% i 230 - 500 V DC Startup < 1.5 W_ 260 V Consupmtion During Operation Via. Input j_ 8 W 14 W 600 V 14 W I Cooling _ I Admissable Conductor Size (DC) No. 14 to 6 AWG. For larger wire, use Fronius connecting distributor. ventilation variable Max Current er UL In ,,['Terminal OUTPUT DATA '-- 3.0 tum' 20 Am .,, For hi her m w �It 3.8-111x[ current, use Froniva cunnee.tin distributor. 5.0 -/UMI 6.0-11,x. 7.5 tum Nominal Output Power I 3,000 W 3,800 W 5,000 W 6,000 W 7,500 W j Max C ommuuu-. Output Powst s 000 W 3.600 W 5,000 w 6.000 W 7, 5uU W AC Output Voltage 208 / 240 / 277 Numbrr of Ph+ur, I 1 Admissible Conductor Size (AC) I No. 14 -4 AWG Max. Continuous 1,1011tyBarkleed ( urrent OA i Nominal Output Frequency 60 Hz O eat'n 7 uen Kane 59,3-60.5 JJZ Total Harmonic Distortion <3% Power F.hetm � GENERAL DATA 3.0-1t,., ` 3.8-1 G um O..ti5- 1 inJ. ca . 5.0-1 ux, 6.0-1 um 7.5-1 1 um CEC Efficiency 208 111 95.0 % 95.0% 95.5% 95.5% 95.0% _ 2_40 Vj 75. i :', 95.5 ;6 95.5 %, 96.0 % 95 5 277 Vi 96.0% 96.0% 96.0% 96.0% 96.0% i Corium tiun m Staruib iNi Iq _ _ _ < 1.5 W_ J Consupmtion During Operation 8 W 8 W 14 W 14 W 14 W I Cooling _ I� Controlled forced ventilation variable speed fan Enclosure Type NEMA 3R r tp5. let 24 lbs. 111 57 I Advanced Grid Features Active and reactive power control, to. voltage ride -through UL 1741-2010, IEEE 1547-2003, IEEE 1547.1, UL 16998-2013, ANSI/IEEE 062.41, FCC Part 15 A K B, NEC Article 690, Compliance �iNo 107.1-01 (Sept. 20111 California Solar Initiative - Progrun Handbook -Appendix C Inverter Integral TY Meter Perfot SQecification TECHNICAL DATA: FRONIUS IG PLUS ADVANCED(IO: INPUT DATA 10.0 - 1oNt Recommended PY-'ewer (LWp) ( 5.50-11.50 Nummal In jut Cirrent Z7.G A Max. Usable Inpct Current %IPP1 - Vole- I 46.7 A .� DC Startup 11,400 W( Max. Input Voltage Max. Continuous Uutpu. P7wer - Admissable Conductor Size (DC) 9995 W %lax. Currentper DCln ut Trrnincl JL— 12.000 W OUTPUT DATP 10.0 - 1oNt 1.4 ICY 11 0.0 3ext DELTA '' 11.4 3uxt DELTA 12.0 - 3 WY32'7 Nominal Output ?ower I 9,995 W 11,400fW 9995 W 11,400 W( 12,000 W Max. Continuous Uutpu. P7wer - 3,995 W11,400 W 9995 W 11 400 W 12.000 W AC Output Voltage 208 / 240 / 277 I 208 / 240/'_' i7 I 208/240 j 208/240 480 / 277 WYE T Number of ?has- !' 1 1 3 L 3 L 3 Admissible ConductorSize(AC) Admissible Anil) eit OP7r:tin¢Tcmperatare No. 4-4AWC Advanced Grid F=atures I Active and :eactive power control, low voltage ride -through Max. C.nnlla'JOU9lit ip B.ckleed Currerz -._�UL1741-2010, IEEE_5�-2003 IEEELS�TIUL1G99B-71 .k .. ';jVo'107,1-01 (Sept.2(kl)>Iiforiia5olrWtative-PrograriHandhook-App_ndixC:InvencrintegralS ctcrPerfcrrarc - OA Nominal Output Frequency 5011Z U matin Ireutrc R:mL 59. - ;0.5 Hz Total Harmonic Distortion ( <3% Power Factum___ 1�_ 0-85 —1 ind. i cap. GENERAL DA'A 10.0 - 1u0t 1.4 - 1u+t �', 10.0 - 3oxi DELTA 11.4 - 3t10 DELTA 12.0-3 WYE2 it Max. Efficiency I 96.2 Unit Dimension M/ > H x !ti _ It .7.1 n F9.7 x 9.9 in. CEC Efficiency 208 VI 95.0% 95.0 1 95.5% 95.0% n.a. _-Al _..9_5.57 95.1'r 95.5'x, 96.0. n.a. 277'✓ 96.0% 96.0 °« n.a. n.a. 96.0% i Cunsurn0liun in ilar.dav (-1iehtl _ _ - 1.5 W Consumption During Ope®tion I` 20W Cooling:on r.11ed Inrerd vetti!atinn, variablespeed Fm Enclosure Type N 3MA 3R Power Stack Wei+ht (381,g) Wiring Compart.writ Weight I 26 ms. (12 kg) Admissible Anil) eit OP7r:tin¢Tcmperatare —-13"F...131•F-23 C...+55°C Advanced Grid F=atures I Active and :eactive power control, low voltage ride -through Compliance --.. r r� .. . -._�UL1741-2010, IEEE_5�-2003 IEEELS�TIUL1G99B-71 .k .. ';jVo'107,1-01 (Sept.2(kl)>Iiforiia5olrWtative-PrograriHandhook-App_ndixC:InvencrintegralS ctcrPerfcrrarc - TKHNICAL DATA: FRONIUS IG PLUS ADVANCED(10.0-1 UN, ? 11.4-1UNI ,10.0UNI t•3 C-ELIA- 11.4-3UNI - D=_lA, 1e.03; WYE277), 10.0 - tort 11.4 - 110M10.0 - 3yxlDEL:.'1 11A- Sul )LLTA = 1$.0 - 3 WYE27� operating AC Voltage Range 203 >/j229 V (-_12 /+i? % ) , y47 544 277 � 244- 375 V (-12 y +ry /o) "a t, Continuous Uut ut c 20 5+.$ A it - 27- A` _-31.e A` n.a. i 24J � 41.7 A I 47.5 A 24D A` � 27.E A` n.a. 2774; 36.1 A 41.2 A iL 14.4 A'�R PftaTECTIVE EQUIPMENT 10.0 -_ luct 11.4- tuxt b.0 3:4N DELA � 17 A - 3rn DELTY 1 2:• - 3 WYE27I 1 6rwnd Fault Protection � Internal CFDI (Ground Fault Detectrr/Intrruhter) in acaodancewith JL 174'--:0E0 aad R EC 4r.. 690 JCRe'+ersePolarit Protecrcn _ frr:ernd Diode- Fslanding Protection Inernal; in accordance v+tth OL 1'41-20118 IL•fai -54i-2003 and [ILC Qv,Temperature Protection S ArrFault Circuit Protection Arc -Fault Circuit Protz_tion (Issue N•rtmr 2, linu:ry 14_2(1231EF=ICIENCY Internal AF:,'I (Arc -Fault Circuit Interrupter); in acccrdaace with UL =699 0L'tliM oFlnsmsigralion fu Photovoltaic (PV) DC w c ^ z � 0 0 0 C U t n L � t cu O / Battery Charging Systems / Welding wchaclogy / S�_Iar ElectronicWE HAVE THREE DIVISIONS AND ONE PASSION: SHIFTING TH' LIMITS. /Whether g - Battery Zhargino Systems.l�J._1cLr1g Technology or Solar Electronics - ocr goal is clearly.d-�ine3 to be tkE techn•lory ;-n-3quality leader With more than 3,000 employees worlc-wide. we shift -..helimits of woof's possible -our_;,3?active patd-.ts Er> teeTmta.} to ths.WI-CIE others prog►es: _ step by step, we in lovate in leaps and Bcurixl::. Furthe- information about all Fronias piodacisand oa global sales partners and rep-esentatives gar be found at www.fronius.com E F7Dijs IISlI LLC o 6%93 Frmit_s Cui-e P•ilage, IN +636& LL lZ h o p'_Lsa@troy iu:.cz) Out t zvetderdin aeive co a -o January 13, 2014 UniRac i 1411 Broadway Boulevard NE it Albuquerque, New Mexico 87102-1545 TEL: (505) 242-6411 FAX: (505) 242-6412 Attn.: Engineering Department, STRt1tTURAL ENGINEERS ROE�E S 1 N IN&S3878 OF CNO Re: Engineering Certification for UniRac's SolarMount Code -Compliant Installation Manual 227.3 PZSE, Inc. -Structural Engineers has reviewed UniRac's "SolarMount Code -Compliant Installation Manual 227.3" published January 2014 and specifically "Part I. Procedure to Determine the Design Wind Load", and "Part II: Procedure to Select Rail Span and Rail Type". The procedures are used to determine the calculation of the design wind force, load combinations, applied loading and rail selection. All information, data and analysis contained within the Installation Manual are based on, and comply with the following: 1. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-05 and ASCE/SEI 7-10 2. 2012 International Building Code, by International Code Council, Inc. 3. 2013 California Building Code, by California Building Standards Commission 4. 2010 Aluminum Design Manual, by The Aluminum Association This letter certifies that the structural calculations contained within UniRac's "SolarMount Code -Compliant Installation Manual 227.3 are in compliance with the above Codes. If you have any questions on the above, do not hesitate to call. Sincerely, Paul Zacher, SE - President 8137 Sunset Avenue, Suite 120 • Fair Oaks, (A 95628 • 916.961.3960 t 9.16.961.3965 f • wwaffil.(OM Engineering Variables Description Variable Value units 3/31/2014 ,' Unirac - Solarnnount / Sunframe Configurator - Project Specs h ..... ...... 15 Solarmount / Sunframe Configurator - Project Specs Roof Angle Proiect Specs Arravinfonnation >7to27 degrees Wind 6posure Name: Jim Lyle Manufacturer: Sunpaner Snow Load Importance Facto Email: cesarlopezxcl@hotmail.com Module Model: E201327 Wind Speed Telephone: Module Size: 61.39" x41.18' mph Effective Wind Area Module Rms xCds 3x14 ft2 Roof Zoe Project Location Number of Arrays 1 Address`. Total Modules 42 Description City, State: La Quinta, CA Total Kilowatts 13.734 Units Net Design Wind Pressure (Uplift) Zip code: 92253 -40,2 psf Net Design Wind Pressure (Downforce) County. Riverside Racking Type SdarMourdRoofrrtound psf Adjustment Facto for Heigh and Etposure Category Basic Wind Speed: 110 mph (User Modified) Module Orientation Portrait Importance Facto Ground Snow Load: 0 psf Rail Direction E -W Design Wind Load (Uplift) Special Notes on Basic W Ind Speed and Snow Load -40.2 psf Design Wind Load (Downforce) ��- 2000 ft. is the upper elevation limit in feet for the ground sn owload value given. 8.9 psf Partof the countyis in a Special Wind Region Material Takeoff Part Number Part Type Description Suggested P Quantity Unit Price Total Quantity 310132C SdarMount Rail SM RAIL 132' CLR 30 30 $72.00 $2,160.00 303002D Splice SM SPLICE BAR SERRATED DRK 24 24 $6.20 $148.80 3021046 Mid Clamps SM MID CLAMP, EFJMN, W/HDW, DRK 78 78 $3.42 $266.76 302006D End Clamps SM ENDCLAMP F. W/HDW, DRK 12 12 $2.87 $34.44 004400D Aluminum Flat Top STANDOFF 4.2 PIECE AL, DRK 78 78 $13.56 $1,057.68 304000D Single L -Feet SM L -FOOT SERRATED WHDW, DRK 78 78 $4.54 $354.43 0040140 Flashing FLASH IN G OATEY 11840 GLVLU M E 78 78 $6.40 $499.20 008002S Grounding Lugs GROUND WEEBLUG#1 54 54 $10.00 $540.00 308001S UGC Clip , SM GROUND CLIP. #1, UGC -1 SS, 42 '_.. 42 $2.29 $96.18 Total Price - Please note these are list prices. Contact your distributor for your system price. $5,157.49 Thermal breaks are required every40 feet. See the Unirac splicing and emwansio idm manual for details. Engineering Variables Description Variable Value units Building Heigh h ..... ...... 15 ft Roof Angle psf >7to27 degrees Wind 6posure -40.2 B Snow Load Importance Facto 0 1 Wind Speed V 110 mph Effective Wind Area Total Load Combination 2 100 ft2 Roof Zoe psf 3 Design W Ind Load Calculation Description Variable Value Units Net Design Wind Pressure (Uplift) Pnet30 (Uplift) -40,2 psf Net Design Wind Pressure (Downforce) Pnet30 (Downforce) 8.9 psf Adjustment Facto for Heigh and Etposure Category A 1 Importance Facto 1 1 Design Wind Load (Uplift) Pnet (Uplift) -40.2 psf Design Wind Load (Downforce) Pnet (Dawnforce) 8.9 psf Load Combinations Calculations Description Variable Downforce Uplift Units Dead Load D 5 5 psf Total Design Wind Load Pnet 10 -40.2 psf Snow Load S 0 Total Load Combination 1 D + 0.75Pnet + 0.75S 125 psf Total Load Combination 2 D + Prmet 15 psf httpJAmmN.Unirac.com/configurators/estimator_roofmounV?module=part&taslresGmator&mode=detail&type=solar8id=98 112 3/31/2014 Unirac - Solarmount/ Sunframe Configurator -Project Specs Value = Total Load Combination 3 D + S 5 Single L psf Total Load Combination 4 0.61) + Pnet -37.2 psf MaxAbsdute Value Load 37.2 SM RAIL 132' CUR psf ReHsed Rail Span L 4 ft Distributed Load Calculation Allowable Spars Description Variable Value Units MapmOmAbsolute Value ofLoad Combinations P ----- ---- 37.2-- ------- psf Module Length Perpendicular to Rails B 5.12 ft Distributed Load (Uplift) w -95.15 plf Distributed Load (Downforce) w 38.37 plf Rall Span Information Description Variable Value Units Rackrg Attachment Type Single L Racking Attachment Aluminum Flat Top Rail preference SM RAIL 132' CUR ReHsed Rail Span L 4 ft Allowable Spars Single L Foot SM 5 ft Single L Foot SMHD 8 ft Double L Foot SM 5 ft Double L Foot SMHD 8 ft Point Load Calculations (per Code, these are based on ma)dmum allovrable spans as shovm in chart above) Description Variable Downforce Uplift Units Single SM Point Load Face R 191.8 -475.8 lbs Single SMHD Point Load Force R 307.0 -761.2 lbs Point Load Calculations for your span are: Rail preference SM RAIL 132' CUR Re4sed Rail Span L 4 ft Solar Mount Point Load Force R 153.5 -380.6 lbs This engineering report and associated bill of materials is to be evaluated to Unirac SdarMount Code Cor pliant Installation Manual 227.3 (Pub 110616-1cc) and SunFrame Code Cornpliant Installation Manual 809 (Pub 110518-2cc) which references International Building Code 2003, 2006, 2009 and ASCE 7-05, ASCE 7-02 and California Building Code 2010. The installation of products related to this engineering report is subject to requirements in the aboxe mentioned installation manual. Rev 3.2 - 8252011 httpJ/www.uni rac.com/config urators/esbmator_roofmountt?module=part&taslresbmator&mode=detail&type=solar&id=98 212 SOLARMOUNT® RAIL OPTIONS PV's most versatile mounting system SolarMount* HD HD (heavy duty) rail adds the SolarMount advantage to PV PoleTops•, U-LAs (see separate data sheets), and custom applications that require long spans. ATTACHMENT OPTIONS Flexible Components Speed Installation Standoffs Use standoffs whenever flashed installations are required, on tile roofs, for example. Two- piece aluminum standoff allow precise place- ment of ,f a Flashing overs secured base prior to the installation of the standoff itself. All standoff types come in four standard heights: 3, q, 6, and 7 inches. Appropriate flashings are available. Serrated L -feet Standard for ground mount installations on v residential and commercial rooftops,use L -feet alone above asphalt composition shingles or in conjunction with flat top standoffs. Mount standard or light rails. Configure to either of two rail heights, one promoting air flow for cooling, the other offering close -to -the -roof * 1 111 aesthetics Strut -in -Tube Style Legs Quickly set the precise tilt angle required. Styles t ( are available for high profile (i or z legs per 1,�. _�' - - ;•�EAU rail) and low profile installations. �. Each serves offers three leg lengths so that you can adjust to exactly the tilt angle you want— up to a maximum of 60 degrees—without cutting and drilling at the job site. Standard SolarMount' Standard rail gives you ultimate flexibility, including40 FastFoot"I bottom mounting and tilt -up options. The FastFootr" attachment features Eco -Fasten MODULE MOUNTING technology by the Alpine Snow Guard Company, allowing attachments to metal, concrete and Assembly Sequence Is Your Choice wood decks without compromising the integrity of the roof. Top Mounting Clamps Bottom Mounting Clips Ideal for flush mount applica- .. _ - Use bottom mounting clips Tile Hook i tions, such as residential rookops, (standard and HD rail only) Made from cast aluminum, the file hook -- where it is most convenient. to whenever you prefer to attachment provides SolarMount with a .i secure footings and rails before preassemble the array using g cost-effective solution for barrel or Spanish installingmodules, to mounting module mounting holes. P g file roofs. All required lag bolts and hardware Clamps securely grip any point of Simply fit the clip into its rail the module frame, freeing you slot over the mounting bolt for are included. Refer to the file hook engineering from the constraints of module a secure connection. Adjust the data for max load capabilities. mounting holes. clip position anywhere along the rail slot. KEY BENEFITS of SolarMount® Rail Maximum flexibility Flush, high-profile or low -profile configurations Roof or ground mount Pitched or flat roof Ease of installation Installer -friendly components Minimized penetration with longer attachment spans than competitive products Designed with customer input Grounding and wire management options Complete technical support Installation and code compliance documentation • Online estimator Person-to-person customer service Core component for Unirac mounting solutions Three rail options to accommodate anyjob site Incorporated into other major product lines moon UNIRAC Bright Thinking in Solar ZZ � •„ dry" ,,,. x- _ .`s--" em ,.aa :vim ''•.�. - . - �-^ ..�:''°° �; �. -,-'" "ww�,-.,> lo r �, ..T `. r _ �,,.f „rr `� _ �^"""� "`- „�•��"•r• - '"sae _. �,�A� s r _.. r .,y - 'di - :r' �.. .,rte „��,. 1°��.. �•F'�'w„�,. .` �� ! � y sw . :, •; ,x e� %°'`, �--.�r xw"` . -.� ,.,yam -4`y i Y �. rt' '�' "r _ ' •a,✓� -'' �^+t�./f x' # tea. r <. -' i'' ' ' .fir �Y,,,. �'.�.�r"� � '�" � `- �/'' � ''i x � "S�¢s'•�'''., \' '.. . 1 � �. f. r.P--' r� r.- �,,..r' '� •{ `"tib. �,., ,r,'' -,.t. ,Ir •J' ' •m d:UNIRAC m A HILTI GROUP COMPANY SolarMount Technical Datasheet Pub 110818-1td V1.0 August 2011 SolarMount Module Connection Hardware.................................................................. 1 BottomUp Module Clip.................................................................................................1 MidClamp....................................................................................................................2 EndClamp....................................................................................................................2 SolarMount Beam Connection Hardware......................................................................3 L-Foot............................................................................................................................ 3 SolarMountBeams..........................................................................................................4 SolarMount Module Connection Hardware BE SolarMount Bottom Up Module Clip PartNo. 302000C Dimensions specified in inches unless noted • Bottom Up Clip material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear Anodized • Bottom Up Clip weight: --0.031 lbs (14g) • Allowable and design loads are valid when components are assembled with SolarMount series beams according to authorized UNIRAC documents • Assemble with one %"-20 ASTM F593 bolt, one'/<" -20 ASTM F594 serrated flange nut, and one 'W' flat washer • Use anti -seize and tighten to 10 ft -lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory • Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut Applied Load Direction Average Ultimate Ibs (N) Allowable Load Ibs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, m Tension, Y+ 1566 (6967) 686 (3052) 2.28 1038 (4615) 0.662 Transverse, Xt 1128 (5019) 329 (1463) 3.43 497 (2213) 0.441 Sliding, Z+ 66 (292) 27 (119) 2.44 1 ' 41 (181) 0.619 SolarMount Mid Clamp PartNo. 302101C, 302101D, 302103C, 302104D, 30210513,30210613 1.0 DKTANCf Wftfen MODUiFS t 1 Y 1 x Dimensions specified in inches unless noted SolarMount End Clamp Part No. 302001C, 302002C, 302002D, 302003C, 302003D,302004C,302004D,302005C,302005D, 302006C,302006D,302007D,302008C,302008D, 302009C,302009D,302010C,302011C,302012C • ::�UNIRAC A HILTI GROUP COMPANY • Mid clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • Mid clamp weight: 0.050 lbs (23g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble mid clamp with one Unirac'/4"-20 T -bolt and one'/4"-20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft -lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, m Tension, Y+ 2020 (8987) 891 (3963) 2.27 1348 (5994) 0.667 Transverse, Z± 1 520 (2313) 229 (1017) 2.27 346 (1539) 0.665 Sliding, X± 1 1194 (5312) 1 490 (2179) 2.44 1 741 (3295) 0.620 - P: A 1.S :�. SIL`:7MCOM VALES NJrrH MMI Dimensions • End clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • End clamp weight: varies based on height: —0.058 lbs (26g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single end clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble with one Unirac'/4"-20 T -bolt and one'/4"-20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft -lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory • Modules must be installed at least 1.5 in from either end of a beam Applied Load Direction Average Ultimate lbs (N) Allowable Load Ibs (N) Safety Factor, FS Design Loads lbs (N) Resistance Factor, 0 Tension, Y+ 1321 (5876) 529 (2352) 2.50 800 (3557) 0.605 Transverse, Z± 63 (279) 14 (61) 4.58 21 (92) 0.330 Sliding, X± 142 (630) 1 52 (231) 1 2.72 79 (349) 0.555 SolarMount Beam Connection Hardware SolarMount L -Foot PartNo. 304000C, 304000D Y I L►X 3:0> A ROT FOR '� ovr?ax t € 2.&1 Dimensions specified in inches unless noted ' •m Ngow o UNIRAC A HIITI GROUP COMPANY • L -Foot material: One of the following extruded aluminum alloys: 6005- T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • L -Foot weight: varies based on height: --0.215 lbs (98g) • Allowable and design loads are valid when components are assembled with SolarMount series beams according to authorized Bolt UNIRAC documents L -Foot For the beam to L -Foot connection: • Assemble with one ASTM F593 W-16 hex head screw and one ASTM F594'/a •serrated flange nut • Use anti -seize and tighten to 30 ft -lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third -party test results from an IAS accredited laboratory NOTE: Loads are given for the L -Foot to beam connection only; be sure to check load limits for standoff, lag screw, or other attachment method Applied Load Direction Average Ultimate lbs (N) Safety Allowable Load Factor, lbs (N) FS Design Load lbs (N) Resistance Factor, 0 Sliding, Z± 1766 (7856) 755 (3356) 2.34 1141 (5077) 0.646 Tension, Y+ 1859 (8269) 707 (3144) 2.63 1069 (4755) 0.575 Compression, Y- 3258 (14492) 1325 (5893) 2.46 2004 (8913) 0.615 Traverse, X± 486 (2162) 213 (949) 2.28 323 (1436) 0.664 -,SOLARMouNT Technical-- i SolarMount Beams Part No. 310132C, 310132C -B, 310168C, 310168C -B, 310168D 310208C, 31.0208C -B, 310240C, 310240C -B, 310240D, 410144M, 410168M, 410204M, 410240M :e�UNIRAC A HILTI GROUP COMPANY Properties Units SolarMount SolarMount HD Beam Height in 2.5 3.0 Approximate Weight (per linear ft) pif 0.811 1.271 Total Cross Sectional Area int 0.676 1.059 Section Modulus (XAxis)in 0.353 0.898 Section Modulus (Y --Axis) in 0.113 0.221 Moment of Inertia (X -Axis) in 0.464 1.450 Moment of Inertia (Y -Axis) in 0.044 0.267 Radius of Gyration (X -Axis) in 0.289 1.170 Radius of Gyration (Y -Axis) in 0.254 0.502 SLOT FOR T -BOLT OR 14" HEX HEAD SCREW 2X SLOT FOR BOTTOM CLIP M .500 T 1.316 SLOT FOR IJU 3y8" HEX BOLT 37 . 750 y L►X SolarMount Beam SLOT FOR T -BOLT OR 1.728 1/4" HEX HEAD SCREW SLOT FOR BOTTOM CLIP �I SLOT FOR 7 1.385 3/8" HEX BOLT 1.207 Y IIS -1.875 A L► X SolarMount HD Beam Dimensions specified in inches unless noted a Standoffs & Flashings Installation Manual 907.2 [1] Installer responsibility QThe installer is solely responsible for: • Complying with all applicable local or national building codes, including any that may supercede this manual; • Ensuring that Unirac and other products are appropriate for the particular installation and the installation environment; • Ensuring that the roof, its rafters, connections, and other structural support members can support the array under building live load conditions; • Using only Unirac parts and installer -supplied parts as specified by Unirac (substitution of parts may void the warranty); • Maintaining the waterproof integrity of the roof, and • Ensuring safe installation of all electrical aspects of the PV array. mon mono U N I RAC A HILTI GROUP COMPANY See www.unirac.conVdistributors foryour nearest Unirac distributor. Unirac welcomes input concerning the accuracy and user-friendliness of this publication. Please write to publications@unirac.com. w ' O U N I RAC Installation Manual 907.2 Standoffs & Flashings Standoffs: 3-,4-, 6-, and 7 -inch lengths in each type Shaft O.D. Use Components !1m Flat top 2 -piece aluminum Use with SunFrame, SolarMount standard, or SolarMount HD rails. Secure to rafter with 2 lag screws. Secure L -foot or installer -supplied 15/8 strut directly to standoff with standoff hardware. Especially convenient when installing over a tile roof because flashing can be precisely fitted over secured base prior to installation of shaft. • Shaft • Base assembly • Bolt, 3/8" x 11/4- Flange Head • Lock washer, 3/8"" • 2 lags, 5/16" x 31/2'* (zinc) • EPDM Washer * A lag -bolt removal credit is available wherever an installer prefers to substitute a different lag bolt The installer is solely responsible for determining wheth- er lags are adequate to handle live and dead loads under wind conditions at the installation site. Wind loads and lag pullout capacities are addressed in Code -Compliant installation manual for SolarMount (Installation Manual 22 7) and SunFrome (Installation Manual 809). Flashings for all current standoffs (0/9" O.D. shaft (see illustrations, p. 3) Use only with SolarMount standard or HD rails. • Welded standoff Raised flange I5/8" Secure to rafter with 2 lag screws at opposite • 2 lags, 5/16- x 31/2 * (zinc) zinc -plated steel corners, orienting the flange parallel to the rails. 8.75"" x 12.5" Collared, soft aluminum 990103 18" x 18" Use with SunFrame, SolarMount standard, or • Welded standoff Flat top 1 -piece I S/e SolarMount HD rails. Secure to rafter with 2 lag • Bolt, 3/8- x 11/47 zinc -plated steel _ screws at opposite corners. Secure L -foot or • Lock washer, 3/8" \\i�" installer -supplied strut directly to standoff with • 2 lags, 5/16" x 31/2 standoff hardware. !1m Flat top 2 -piece aluminum Use with SunFrame, SolarMount standard, or SolarMount HD rails. Secure to rafter with 2 lag screws. Secure L -foot or installer -supplied 15/8 strut directly to standoff with standoff hardware. Especially convenient when installing over a tile roof because flashing can be precisely fitted over secured base prior to installation of shaft. • Shaft • Base assembly • Bolt, 3/8" x 11/4- Flange Head • Lock washer, 3/8"" • 2 lags, 5/16" x 31/2'* (zinc) • EPDM Washer * A lag -bolt removal credit is available wherever an installer prefers to substitute a different lag bolt The installer is solely responsible for determining wheth- er lags are adequate to handle live and dead loads under wind conditions at the installation site. Wind loads and lag pullout capacities are addressed in Code -Compliant installation manual for SolarMount (Installation Manual 22 7) and SunFrome (Installation Manual 809). Flashings for all current standoffs (0/9" O.D. shaft (see illustrations, p. 3) *Packs of 12 flashings. Flashings for other uses (1/2' - 11/8' O.D. shaft) Part no. Dimensions Collared, galvanized 990109 8.75"" x 12.5"" Flashing refers to thin, continuous pieces of sheet metal or other impervious material installed to prevent the passage of water into a structure from an angle or joint. Flashing generally operates on the principal that, for water to penetrate a joint, it must work itself upward against the force of gravity or in the case of wind -driven rain, it would have to follow a tortuous path during which the driving force will be dissi- pated. Unirac offers flashings to be used specifically with Unirac standoffs. These flashings are collared, thereby eliminating the need for the use of sealant between standoff and flashing. The flashing slides over the standoff, under the shingle above, and over the shingle below. The following installation instruction. provides an explanation of planning and installation of three different applications. Part no.* Dimensions Collared, galvanized 990101 8.75" x 12.5" Collared, aluminum 990102 8.75"" x 12.5" Collared, soft aluminum 990103 18" x 18" *Packs of 12 flashings. Flashings for other uses (1/2' - 11/8' O.D. shaft) Part no. Dimensions Collared, galvanized 990109 8.75"" x 12.5"" Flashing refers to thin, continuous pieces of sheet metal or other impervious material installed to prevent the passage of water into a structure from an angle or joint. Flashing generally operates on the principal that, for water to penetrate a joint, it must work itself upward against the force of gravity or in the case of wind -driven rain, it would have to follow a tortuous path during which the driving force will be dissi- pated. Unirac offers flashings to be used specifically with Unirac standoffs. These flashings are collared, thereby eliminating the need for the use of sealant between standoff and flashing. The flashing slides over the standoff, under the shingle above, and over the shingle below. The following installation instruction. provides an explanation of planning and installation of three different applications. Standoffs & Flashings Installation Manual 907.2 UNI RAC i Planning and installation There are many possible configurations of standoffs and flashing. The three examples here illustrate major product varieties and installation settings. Example 1 2 -piece, aluminum, flat top standoff Soft aluminum flashing Tile roof SunFrame (shown) or SolarMount rail 1 SunFrame h' rail= L -foot Tim. r Mold Flashing — Rafter to the Remove a tile over a rafter. Install the base of a two-piece standoff, ensuring that both lag bolts are screwed into the rafter. Install soft aluminum flashing over the base, inserting it under the tile above and forming it to the shape of the tile. Insert standoff shaft through the opening in the flashing screwing it down firmly in place onto the base. Seal with roofing cement or other appropriate compound. Attach L feet to standoffs. Slide L foot mounting bolts along slot on SunFrame (or SolarMount) rail. Insert footing bolts through L feet and fasten with flange nuts. Example 2 1 -piece, steel, flat top standoff No -Calk"' flashing Shingled roof SunFrame (shown) or SolarMount rail r SunFrame k Shingle rail t.• �r L -foot Rafter No -Calk collar —► Cut an opening in the roofing material over a rafter to accommodate the flashing riser. Install the standoff, ensuring that both lag bolts are screwed into the rafter. Insert the flashing under the shingle above and over the shaft of the standoff. No -Calk collar does not require sealing of the flashing and standoff shaft. Attach L -feet to standoffs. Slide L foot mounting bolts along slot on SunFrame (or SolarMount) rail. Insert footing bolts through L feet and fasten with flange nuts. ::'UNI RAC Installation Manual 907.2 Standoffs &Flashings Example 3 1 -piece, steel, raised -flange standoff No -Calk- flashing Shingled roof SolarMount rail SolarMount rail Shingle Rafter No -Calk collar --s Cut an opening in the roofing material over a rafter to accommodate the flashing riser. Install the standoff, ensuring that (1) both lag bolts are screwed into the rafter, and (2) the raised flange is oriented parallel to the rail. Insert the flashing under the shingle above and over the shaft of the standoff. No -Calk- collar does not require sealing of the flashing and standoff shaft. Slide mounting bolts along slot on SolarMount rail. Insert footing bolts through raised flange on standoff and fasten with flange nuts. 10 year limited Product Warranty Univac, Inc., warrants to the original purchaser ("Purchaser") of product(s) that it manufactures ("Product') at the original installation site that the Product shall be free from defects in material and workmanship for a period of ten (10) years, from the earlier of 1) the date the installation of the Product is completed, or 2) 30 days after the purchase of the Product by the original Purchaser.This Warranty does not cover damage to the Product that occurs during its shipment, storage, or installation. This Warranty shall beVOID if installation of the Product is not performed in accordance with Unirac's written installation instructions, or if the Product has been modified, repaired, or reworked in a manner not previously authorized by Univac IN WRITING, or if the Product is installed in an environment for which it was not designed. Unirac shall not be liable for consequential, contingent or incidental damages arising out of the use of the Product by the Purchaser under any circumstances. If within the specified Warranty period the Product shall be reasonably proven to be defective, then Unirac shall repair or replace the defective Product, or arty part thereof, in Unirac's sole discretion. Such repair or replacement shall completely satisfy and discharge all of Unirac's liability with respect to this limited Warranty. Under no circumstances shall Unirac be liable for special, indirect or consequential damages arising out of or related to use by Purchaser of the Product Manufacturers of related items, such as PV modules and flashings, may provide written warranties of their own. Unirac's limited Warranty covers only its Product, and not any related items. ��� � � I RAC 1411 Broadway Boulevard NE P,p N Albuquerque NM 87102-1S4S USA 4 LAJILeLj Advancing Renewable Technology ACCAcrne Cable Clips ACME Cable Clips simplify wire management and create a cleaner aesthetic to solar PV arrays. The clips are made of corrosion resistant stainless steel and are designed to prevent damage to cable insu- lation. The easy to install and remove design only requires a flat head screwdriver and can be reused, unlike zip ties. The universal design fits most modules and can hold one or two wires. • Made with corrosion resistant 300 series stainless steel • Dual wire compartments • Special tab for easy installation and removal with flat -head screwdriver • Designed to prevent damage to cable insulation • Sized for USE -2 cable (5-5.4mm) or PV cable (6.8-7.2mm) ACC Holds: 1 to 2 USE -2 wires or 1 PV wire DC Power Systems (800) 967-6917 www.dcpower-systems.com ACC- PV Holds: 1 to 2 PV wires Contact us at: 845.247.4708'.www.we-lic.com _ RMOU TM NT Top Mounting UniRac Grounding, Clips and WEEBLugs = 225.6 UGC -1 ' To �> mou ning c I clamps Module i x i Nib C ��I uS I I Figure 26 Slide UGC -1 grounding u...:.._ ..I . e:€_€_`€.r. aL_j �a UGC 1 i—lv �,,� eli-intotopmountings(oto rail f .. r Intertek .. + _ = Torque modules in pldce on top of eonru.ms co; - clip. Nibs will penerinte rail 'anod- uL sa„dare'4e7? 8, r izationhndcreategrounding-path, � SolarMounf®rdihjan through,rail (see Fig: 3;, reverse side). ; v e NP 1 ■■or■®�■ ®�■�®■r®. ®��■rrr®, rrrr�r®■ fture ' .. . even �■rr■■■r mer■®r�■..■�rr■■� rr■■r■�®■ rrrrrr■ r■r■rr�r. ®■terror■. ®r�r��®■. and , � . .. "X" denotes places to install UGC -I. A■i®w■wi■■ rwr®®r®®. �r®r■i®sr. �rr■�r■r ■■■■■■r■ ■■■srt�r rrrr■■rr ®a■■■tr■ Even Number ofModules in row r■r�■�r■ �€r�r■■�®. ®r�r■■■rr. do�r�rr■. 'rrr■■■■■ r■■■■t■■ r■r■re�■®■■■■■r■■ �■■rrrr■ rr■®■rrr rrr■r■rr ■s■rrr®■ UNI RAC Installation Sheet 225.6 Unirac Grounding Clips and WEEBLugs 10 year limited Product Warranty See http://www.unirac.com for current warranty documents and information. YOUR UNIRAC DISTRIBUTOR SOLIGENT Soligent 4 www.s7-6917 www.soligent.net r t,Y N I RAC1411 Broadway Boulevard NE ma U Albuquerque NM 8'7102 -1545 -USA' Pogc 2 r i Product Data Sheet DU222RB SWITCH NOT FUSIBLE GD 240V 60A 2P NEMA3R t. " .....,. If"M UUi Technical Characteristics a j SQUARE 33 W Schneider Elcctrfc List Price $353.00 USD Availability Stock Item: This item is normally stocked in our distribution facility. Number of Poles 2 -Pole Terminal Type Lugs Type of Duty General Duty Maximum Voltage Rating 240VAC Wire Size #10 to #2 AWG(AI) - #14 to #2 AWG(Cu) Action Single Throw Ampere Rating 60A Approvals UL Listed File Number E2875 Enclosure Rating NEMA3R Enclosure Type Rainproof and Sleet/Ice proof (Indoor/Outdoor) Factory Installed Neutral No Disconnect Type Non -Fusible Mounting Type Surface Shipping and Ordering Category 00106 - Safety Switch, General Duty, 30 - 200 Amp, NEMA3R Discount Schedule DE1A GTIN 00785901491491 Package Quantity 1 Weight 4.7 lbs. Availability Code Stock Item: This item is normally stocked in our distribution facility. Retumability Y Country of Origin MX As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document Generated: 11/17/2011 17:11:35 ® 2011 Schneider Electric. All rights reserved. Schneider Electric