14-0404 (SOL) Revision 1 Solar PlansALL CONSTRUCTION SHALL COMPLY WITH THE 2013 CALIFORNIA RESIDENTIAL, 2013 ELECTRICA ZONAL ELECTRICAL CODE. EXISTING METER # AK164-3606 PROPOSED BI-DIRECTIONAL METER EXISTING 200A MAIN SERVICE PANEL AIC RATING 10,000 AMPERES 120/240 VOLT, 1 (1), 3W LOCATED ON WEST EXTERIOR WALL 60 AMP AC DISCONNECT \ SQUARE -D #DU222RB 120/240 VOLT LOCATED NEXT TO MAIN PANEL 60 AMP AC DISCONNECT SQUARE -D #DU222RB 120/240 VOLT LOCATED IN GARAGE FRONIUS 10000 WATT INVERTER FRONIUS IG PLUS ADVANCE 10.0-1 120/240 VOLT - LOCATED IN GARAGE SOLAR MODULES ®- STRING #1 F1- STRING #2 - STRING #3 ❑ -STRING #4 HORSESHOE Rn 0 POOL PATIO COVER SOLAR SYSTEM SIZE: 10.464 kW DC CEC AC SYSTEM SIZE: 9.211 kW AC, 1. THIS IS A 10.464 KW SOLAR ELECTRIC SYSTEM USING (32) SUNPOWER SPR-327NE-WHT-D (327 WATT) PHOTOVOLTAIC MODULES. 2. THIS SYSTEM IS GRID-INTERTIED VIA UL -LISTED POWER CONDITIONING INVERTER: (1) FRONIUS IG PLUS ADVANCED 10.0-1 3. THIS SYSTEM HAS NO UPS, NO BATTERIES. 4. THIS IS A ROOF MOUNTED SYSTEM, ADDING 2.68 LB/SQ FT. FOLLOWING THE ROOF SLOPE. ROOF IS SPANISH TILE AT 17° PITCH (AVG 17°). 5. THE SYSTEMS SQUARE FOOTAGE IS 580 FT' (16% OF TOTAL ROOF AREA). THE MODULES AZIMUTH IS 196°(AVG 196°). 6. MODULES ARE 0 DEGREES TILT ABOVE ROOF SLOPE, NOT TO EXCEED 18" ABOVE ROOF SURFACE. 7. BUILDING IS A SINGLE STORY DWELLING. 8. LAG SCREWS ARE 3/8" X 4" AT 48" O.C. MAX, WITH 2.5" INTO FRAMING. 9. MODULES WILL BE SECURED TO ROOFTOP USING UNIRAC STANDOFF ATTACHMENTS. 10. ATTACHMENTS WILL BE DOUBLE -FLASHED. 11. DESIGNED FOR BASIC WIND SPEED OF 110 MPH PER UNIRAC CALCULATIONS, SEE SPECS. 12. VISIBLE EXPOSED CONDUIT SHALL BE PAINTED TO MATCH. 13. MODULE DIMENSIONS ARE 41.2" X 61.4" 14. SYSTEM INSTALLATION SHALL BE PER NEC 690 AND IS.SUBJECT TO FIELD INSPECTION BY THE CITY. 15. PROPER CLEARANCES SHALL BE IN ACCORDANCE WITH ALL ADOPTED CAL FIRE GUIDELINES. CITY 0F7CA___0UINTA BUILDING®T. & SAFETY.DEP A �' ROVED FOR CONSTRUCTION DATE50Z317-41n - 13Y__R4 _____ I SCALE PV Installation Company Renova Energy Corp. California - 2012 Ammiaan Boob of nc9 u V ai c o > Qo M 04 � u') U c rn MF` W CNI _ C ) U) l0 (D 0 o-��VO E vU Of LO d C 0 U w PV Installation Company Renova Energy Corp. California - 2012 Ammiaan Boob of Drawn By: ` CESAR LOPEZ , Date Drawn: 4 05/21/2014 40 Revision No. S 9 2 Sheet No. 1$1 20' o O M u') W CNI _ C14 M 0 w U ago L w Q J Z 4 �.. U-) J cv) Cl z�tig U N 'o n Drawn By: ` CESAR LOPEZ , Date Drawn: 4 05/21/2014 40 Revision No. S 9 2 Sheet No. 1$1 20' o WARNING: ELECTRIC SHOCK HAZARD. DO NOT TOUC TERMINALS. TERMINALS ON BOTH THE LIN AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. OPERATING CURRENT: 23.9 Amps OPERATING VOLTAGE: 357.1 Volts MAXIMUM VOLTAGE: 550.3 Volts SHORT-CIRCUIT CURRENT: 25.8 Amps BACKGROUND "RED" AND "WHITE" LETTERING. NOTE: MOUNT ON DC DISCONNECT 1P,3W CIRCUIT CODE: OF FRONIUS INVERTER fo VA LOAD LOAD DESCRIPTIONp A B W O TYPE C.B. BACKGROUND 3 a) THIS PANEL IS FED BY TWO SOURCES: U � "RED" AND 1 4997.5 Fronius IG Plus Advanced 10.0-1 UTILITY AND SOLAR PHOTOVOLTAIC 60 60 2 "WHITE" L o LETTERING. NOTE: MOUNT ON MAIN SERVICE PANEL COVER L 4" ®WARNING: THIS FACILITY IS EQUIPPED WITH A PHOTOVOLTAIC GENERATOR LOCATED ON THE ROOF AS SHOWN. THE SYSTEM MAY BE DISCONNECTED FROM THE FACILITY PER THE AC DISCONNECT AS SHOWN. 200A MAIN SITE PLAN PANEL 60 AMP AC DISCONNECT (NEXT TO PANEL) 60 AMP AC DISCONNECT (INSIDE GARAGE) FRONIUS 10000W INVERTER (INSIDE GARAGE) 0 NOTE: MOUNT ON SERVICE PANEL *ALL PLACARDS SHALL BE RED WITH WHITE LETTERING PROJECT SIGNAGE SCALE: N/A WARNING: ELECTRIC SHOCK HAZARD. DO NOT TOUC TERMINALS. TERMINALS ON BOTH THE LIN AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. MAX AC OPERATING CURRENT: 41.7 Amps OPERATING AC VOLTAGE: 240 Volts NOTE: MOUNT ON AC DISCONNECT 3" WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, THE NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. NOTE: MOUNT ON INVERTER W WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. NOTE: MOUNT ON MAIN SERVICE PANEL AT SOLAR BREAKER 3" _ PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATIONS NOTE: MOUNT ON DISCONNECTS 3" THE MAIN BREAKER HAS BEEN DOWN -SIZED TO 175 AMPS T NO UP-SIZING IS PERMITTED NOTE: MOUNT NEXT TO MAIN BREAKER SAFEGUARDS * SOLAR BREAKER SHALL BE LISTED FOR USE IN EXISTING MAIN PANEL. ACCEPTED BREAKER REPLACEMENTS ARE EATON, SQUARE -D & GE. * ALL JUNCTION BOXES SHALL BE NEMA OUTDOOR/RAINTIGHT RATED. * WILEY CABLE CLIPS SHALL BE USED. * ALL EMT SHALL USE OUTDOOR RAINTIGHT COMPRESSION FITTINGS. * SERIES SOLAR CIRCUITS SHALL BE FUSED AT 15 AMPS DC. * ALL EQUIPMENT SHALL BE LABELED. * ADD COMBINER / JUNCTION BOXES AS NEEDED. * AN INTERNAL BLOCKING DIODE IS PROVIDED IN EACH MODULE. *GROUND FAULT PROTECTION DEVICE IS INTERNALLY BUILT INTO SUNPOWER INVERTERS. *MODULE GROUNDING SHALL BE MADE WITH ILSCO GBL-4DB LUGS AND #8 SOLID BARE COPPER USING WEEB CONNECTIONS. *ALL NEUTRAL TO GROUND CONNECTIONS SHALL OCCUR IN THE MAIN PANEL. *EMT SHALL BE 1" MINIMUM. * JUNCTION BOX/ COMBINER BOX ENTRY SHALL USE COMPRESSION FITTINGS. MATERIALS (32) SUNPOWER 327 WATT PHOTOVOLTAIC MODULES #SPR-327NE-WHT-D (1) FRONIUS IG PLUS ADVANCED 10.0-1 - 9,995 W; 240 VOLT (2) SQUARE -D AC DISCONNECT, 60A NON -FUSIBLE, 2 -POLE #DU222RB SOLAR PRODUCTION SUMMARY GROSS NAMEPLATE RATING (32 x 327/1000) 10.464 kW CEC-AC SYSTEM SIZE 9.211 kW WE S NOTES+ SOLAR PRODUCTION STATS. I SN ALE. 2 I P.V. PLAN ° NIA 'I PANEL: MAIN PANELVOLTAGE: 240/120 LOCATION: EXTERIOR WEST WALL BUS: 200 A MOUNTING: FLUSH AIC RATING: 10,000 1P,3W CIRCUIT CODE: NINON -CONTINUOUS L: LONG -CONTINUOUS R: DEMANDABLE RECEPTACLES K: KITCHEN fo VA LOAD LOAD DESCRIPTIONp A B W O TYPE C.B. BUS C.B. TYPE W p U a) VA LOAD LOAD DESCRIPTION A B U � N R L TR P A B TR P L R N 1 4997.5 Fronius IG Plus Advanced 10.0-1 L 60 60 2 x L o 2 3 4997.5 Fronius IG Plus Advanced 10.0-1 L - -I ix— I I 1L 4 4997.5 4997.5 PHASE TOTALS PHASE TOTALS * EXISTING LOADS UNKNOWN TOTAL PHASE A: TOTAL PHASE B: PHASE TOTALS A+B 4997.5 4997.5 CONNECTED VA (CODE N): CONNECTED VA (CODE L): 9995 CONNECTED VA (CODE R): CONNECTED VA (CODE K): TOTAL CONNECTED KVA: 9.995 DEMAND KVA TOTAL ADJUSTED KVA: 9.995 TOTAL PANEL AMPS: 41.7 AMPS W/L CL: 41. MAIN PANEL SCHEDULE �N;A NOTES 1. THE PV SOURCE CIRCUIT IS POSITIVELY GROUNDED. SUPPORT SYSTEM 2. WIRE AND SIZES ARE AS INDICATED OR LARGER. *WIND LOAD: BASIC WIND SPEED (3 -SECOND GUST, 110 MPH) 3. ALL EQUIPMENT IS BONDED BY MECHANICAL MEANS OR BY A GROUNDING CONDUCTOR. * WIND EXPOSURE C 4. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE #8 AWG COPPER GROUND WIRE * CONDUIT SUPPORT BY COOPER/BEELINE OR CADDY AND BONDED TO THE EXISTING GROUNDING ELECTRODE SYSTEM. * VISIBLE AND ACCESSIBLE 5. CHANGES TO DESIGN NEED PRIOR ENGINEER APPROVAL. * SOLARMOUNT RACKING SYSTEM, LAG BOLTED DIRECTLY MARKING INTO RAFTERS. *MARKING IS REQUIRED ON INTERIOR AND EXTERIOR DIRECT CURRECT (DC) CONDUIT, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES AND DISCONNECTS. (CRC R331.2) *THE MATERIAL USED FOR MARKING SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. MARKING AS REQUIRED IN SECTIONS R 331.2.2 THROUGH R331.2.4 SHALL HAVE LETTERS CAPITALIZED WITH A MINIMUM HEIGHT OF 3/8" WHITE ON RED BACKGROUND. (CRC R331.2.1) "THE MARKING CONTENT SHALL CONTAIN THE WORDS "WARNING; PHOTOVOLTAIC POWER SOURCE" (CRC R331.2.2) *THE MAIN SERVICE MARKING SHALL BE PLACED ADJACENT TO THE MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM THE LOCATION WHERE THE DISCONNECT IS OPERATED. (CRC R311.2.3) *THE MARKING SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES EVERY 10 FEET, WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS. (CRC R331.2.4) CITY OF LA QUINTA BUILDING & SAFETY DEPT AP �" JD FOR CONSTRUCTION DATE BY t—�!--- 4 .f PV Installation �� Company Renova Energy Corp. California - 2012 1 .enAi,M F.nnrgy F'nctiuonns E M z m 0 a W M W L0 M o W V 00 � W Q I--- J X: Z JJ M CY c 0 J Drawn By: CESAR LOPEZ Date Drawn: 05/21/2014 Revision No. Sheet No. %i rs fo a; Qo 0 D.0 0 O CD a) 0TNQ 1C rn�U , Goo) w0y^, U a) US i 1- M a) CD C o ;fro o �CLO ova LO C1 c 0 U 4 .f PV Installation �� Company Renova Energy Corp. California - 2012 1 .enAi,M F.nnrgy F'nctiuonns E M z m 0 a W M W L0 M o W V 00 � W Q I--- J X: Z JJ M CY c 0 J Drawn By: CESAR LOPEZ Date Drawn: 05/21/2014 Revision No. Sheet No. %i —� TO IID Solar System Size: 10.464 kW DC MAIN PANEL EXISTING 200 AMP MAIN SERVICE PANEL to ai SOLAR ARRAY CEC System Size: 9.211 kW AC AIC RATING 10,000 AMPERES 240/120 VOLT, 2-POLE y ¢> o 0 co (32) SUNPOWER 327 WATT NUMBER OF WIRES: (3) THREE LOCATED ON WEST EXTERIOR WALL PPHOTOVOLTAIC MODULES SINGLE PHASE �°'�' `� 0 #SPR-327NE-WHT-D METER # AK164-3606 MODULE PTC RATING: 301 AW (2) #6 THWN-2 PROPOSED BI-DIRECTIONAL 2) cai h a °' � t (4 STRINGS OF 8 MODULES) (1) #6 THWN-2 NEUTRAL METER # DC DISCONNECT 1 #8 THWN-2 EGC w y ^� C ; 1 FUSED AT 15 AMPS FRONIUS IG PLUS �1) #8 THWN-2 GEC DOWNSIZE EXISTING 2 0A c� E—>� AVANCED 10.0-1 1" EMT 0 MAIN BREAKER TO 175 a)— a pro INVERTER 0 240 V, 2P 20 AMP lSOLA U BREAKER) BREA ER J IJNBAR M' � 60 AMP NON-FUSIBLE 60 AMP NON-FUSIBLE G BAR LOCATED IN AC DISCONNECT AC DISCONNECT PV Installation GARAGE SQUARE-D #DU222RB SQUARE-D #DU222RB Company 240V, 2P 240V, 2P Renova Energy Corp. (8) #8 THWN-2 LOCATED IN GARAGE LOCATED NEXT TO PANEL GEC CaUfornia - 2012 (1) #8 THWN-2 EGC GROUND '1 1/4" EMT (2) #6 THWN-2 TO 60 AMP 2-POLE 0 SOLAR BREAKER * ALL WIRING BETWEEN MODULES SHALL BE TYPE USE-2 OR PV-WIRE IF EXPOSED. "A°"I'­°kwaoe°°'Cp I ABCt' (1) #6 THWN-2 NEUTRAL 7 ALL CONDUIT SHALL BE 1" EMT OR LARGER. 0 ALL CONDUIT SHALL BE BONDED. 1 #8 THWN-2 EGC ALL CONDUIT SHALL BE SUPPORTED BY RUBBER PYRAMID SUPPORTS. �1; #8 THWN-2 GEC (CONNECTED TO GND) EMT ENTRY MAIN PANEL STEEL CITY 6"X6"X4" (OR LARGER) OUTDOOR JUNCTION BOXES SHALL BE USED AS NEEDED. R TO BE DETERMINED IN FIELD MONITOR/ PV SUPERVISOR ALL CONDUIT SHALL HAVE PLASTIC STRAIN RELIEF CONNECTORS TO PROTECT WIRES. INTERNET 120 VOLT SINGLE LINE DIAGRAM SCALE: o - co DC CIRCUITS AC CIRCUITS LO O 04 M 07 MODULES TO FRONIUS 1000OW INVERTER= FRONIUS 10000W INVERTER TO MAIN PANEL O (n Q 4 STRINGS X 8 MODULES = 32 MODULES O L1J (� MAX VOLTAGE DC = MODULE Voc + ((25*C - Temp Record Low C via www.solarabcs.or x T coe X # modules in series 9995W/ 240 VOLT = 41.65A X 1.25[PER NEC 215.2(A)1] = 52.1 AMPS (60 AMP SOLAR BREAKER) LO MAX VOLTAGE DC= (64.9 +((25°C - 3°C) x.1766)) X 8 modules in series = 550.3 VOLTS AC CONDUIT SHALL BE MOUNTED INSIDE GARAGE W 0 H 6.46 AMPS EACH CIRCUIT X 1.56[PER NEC 690.8] = 10.1 AMPS ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR & 44°C AMBIENT TEMP. PER SOLARABCS.ORG J = Z FUSED AT 15 AMPS EACH CIRCUIT LOCATED AT INVERTER #6 WIRE = 75 AMPS X .82[PER NEC TABLE 310.15(B)(16) & PER NEC TABLE 690.31(C)] = 61.5 AMPS J M E5 DC CONDUIT SHALL BE MOUNTED 1/2" TO 3 1/2" ABOVE ROOFTOP SURFACE. 61.5 AMPS X 1.0[CONDUIT FILL PER NEC TABLE 310.15(B)(3)(a)] = 61.5 AMPS > 60 AMPS = OK 0 ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR & 44°C AMBIENT TEMP. PER SOLARABCS.ORG(3) #6 THWN-2 AWG WIRE, (2) #8 THWN-2 GROUND 02 z #8 WIRE = 55 AMPS X .58[PER NEC TABLE 310.15(B)(16) & PER NEC TABLE 690.31(C)] = 31.9 AMPS 1" EMT @ 40% FILL PER NEC TABLE C.1 = (7) #6 THWN-2 WIRES = OK aU' 2 31.9 AMPS X .70[CONDUIT FILL PER NEC TABLE 310.15(B)(3)(a)] = 22.3 AMPS > 15 AMPS = OK a.. 4 STRINGS= (8) #8 THWN-2 AWG WIRE, (1) #8 THWN-2 GROUND Drawn By: 1 1/4" EMT @ 40% FILL PER NEC TABLE CA = (16) #8 THWN-2 WIRES = OK - —CESAR MAIN PANEL BACKFEED CALCULATION CITY OF LA QUINTA LOPEZ _ EXISTING 200 AMP MAIN SERVICE PANEL BUILDING & SAFE I Y DEPT. Date Drawn: DOWNSIZE EXISTING 200 AMP MAIN BREAKER TO 175 AMP APPROVED A P P R V 05/21/2014 120% OF 200 AMP BUSS: ALLOWABLE BACKFED AMPS [PER NEC 705.12(D)(2)] = 240 AMPS Revision No. 240 AMP - 175 AMP MAIN BREAKER = 65 TOTAL AMP ALLOWABLE CONSTRUCTION FOR 60 AMP SOLAR BREAKER:5 65 AMPS = OK 1 ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 CALIFORNIA RESIDENTIAL, sheet No. Y 2013 ELECTRICAL CODE BASED ON THE 2011 NATIONAL ELECTRICAL CODE. DATE B*=j CALCULATIONS SCALE: E.2 12- - TOP VIEW a�`° ELEVATION —A' � Qo 0 _ a0 O @ N M in 0 rn�UC08 CV C > 10 rn �MYO 0 Cao Evm �� l0 La 0 U PV Installation Company Renova Energy Corp. CaUfornia - 2012 A- NoM AmeManBoeN of NABCEP a MODULES NOT TO EXCEED 18" ABOVE ROOF SURFACE SCALE: 2 ELEVATION B—B M LU LO M = 0) OW At Q U LO H J = Z Jto M CO Q 0) Z � J CD 0 0 - Drawn By: CESAR LOPEZ A Date Drawn: 05/21/2014 Revision No. 2 i l Sheet No. MODULES NOT TO"EXCEED 18" ABOVE ROOF SURFACE MODULES -NOT TO EXCEED 18" ABOVE ROOF SURFACE P. 1 , SCALE: 3