Alta Verde - Pasa Tiempo TR 34243 (Plans 1-3) Revision 1 - Title 24LA QUINTA, CA
CLIMATE ZONE,15
i .
D & R Calcs .
CITY OF LA QUINTA
BUILDING & SAFETY DEPT..
APPROVED
FOR CONSTRUCTION
DATE,'zi — + BY .
Title 24 Energy Calculations D & R Calcs
Micropas v7.10 Performance Method (858) 486-9506®0�
August 16, 2006
TITLE 24 COMPLIANCE REQUIREMENTS SUMMARY
PASA Tiempo Plan 1
'Ceiling Insulation = R-30 min. PROVIDE RADIANT BARRIER ROOF SHEATHING
(NOTE ON PLANS)
Wall Insulation. = R-19 min.
Floor Insulation = N/A
Thermal Mass Areas = See floor plan
Glazing All windows & doors to be dual glazed. Allglass is Low E.
Glazing shall be installed with a NFRC certifying label
attached showing Uvalue.
Solar Heat Gain Co -efficient = 0. 35. windows & doors
Uvalue = 0 40 vinyl/wd windows
Owner to purchase windows &doors w/ specified Uvalues'& SHGC's or better.
Hot Water Heater = (1) 75 GAL a. o. Smith #BTC-251-*** or eq. Standby loss
2.0 min. Provide demand recirc pump..
Infiltration— Standard
AFUE
- 0 .,78 min.
SEER
- 13. 0 min
WITH
TXV
Duct
Insulation
= R-4:2 min. PROVIDE DUCT
TESTING BY
HERS
RATER
Heater sizing
Zone 1 "LIVING".
Zone 2 "SLEEPING/' -
Air Conditioning -
Zoned "LIVING"
Zone 2 "SLEEPING"
Sensible heat load.- 25,063.Btu
(Verify HVAC equip. w/ Mechanical)
Sensible heat load - 24,035 Btu
(Verify HVAC equip. w/ Mechanical)
Sensible cool'g
load
= 19,602
Btu
Latent cool'g
load-
= 4,724
Btu*,
Sensible cool'g
load
='18,467.Btu
Latent cool'g
load
= 4,450
Btu
Verify HVAC sizing & equipment with a Mechanical Engineer/Contractor.
Owner may install any Make & Model HVAC equipment that is equal or greater
than the minimum efficiencies.listed above. All equipment is listed "or eq"
~ERTIFICATE OF
COMPLIANCE: RESIDENTIAL COMPUTER METHOD,
CF-1R
Page 1
Project Title..........
Pasa Tiempo
Plan,.l
----------------
Date..08/16/06
10:09:35
?roject.Address.,.......
5th & Madison
******* ---------------------
La Quinta
*v7.10*
)ocumentation Author...
Diane P. Mendoza
*******
Building Permit #
D & R Calcs
14107.Ipava
Drive
Plan Check /
Date
Poway,' CA
92064
858-486-9506
Field Check/Date
_'limate Zone...........
15
---------------------
"bmpliance Method...:..
MICROPAS7 v7.10
for 2005
Standards
by Enercomp,
Inc.
MICROPAS7
v7.10
File-PSTMPOI
Wth-CTZ15SO5
Program -FORM
CF-1R
1 User#-MP0864
--------------------------------------=---------------------------------------
User-D &
R Calcs Run-Pasa
Tiempo
Plan 1
=
MICROPAS7
ENERGY USE
SUMMARY
=
= Energy
Use,
Standard
Proposed
Compliance =
_ (kTDV/sf-yr)
Design
Design
Margin =
- Space
Heating..........
2.04
1.97
0.07
= Space
Cooling..........
70.74
67.87
2.87 =
= Water
Heating..........
.
9.66
9.97
-0.31. _
=
North
Total
82.44.
79.81
2.63 =
= Space
Heating..........
2.04
2.10
-0.06 =
= Space
Cooling:.........
70.74
68.09
2.65 _
Water
Heating..........
9.66
9.97
-0.31 =
=
East Total
82.44
80.16
2.28
- Space
Heating..........
2."04
2.13
-0.09 =
- Space
Cooling..........
70.74
67.24
3.50 =
= Water
Heating..........
9.66
.9.97
-0.31 =
=
South
Total.
82.44
79.34
3.10 =
= Space
Heating..........
2.04
2.04
0.00 _
= Space
Cooling..........
70.74
67.98
2.76 =
= Water
Heating..
......
9.66
9.91
-0.31 =
_
West Total-
82.44
79.99
2.45 =
_ ***
Building
complies
with Computer
Performance
_
*** HERS.Verification
Required -for
Compliance
:ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2
-------------------------------------------------------------------------------
?roject Title.......... Pasa Tiempo Plan 1 Date..08/16/06 10:09:35
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOI Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 1
---------'----------------------------------------------------------------------
GENERAL INFORMATION
HERS Verification.......... Required
Conditioned Floor Area..... 2659 sf
Building Type.............. Single Family Detached
Construction Type ......... New
Fuel Type ................. NaturalGas
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... FullYear
Floor Construction Type....
Number of -Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage..........
Average Glazing U-factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Slab On Grade
2
28198 cf
265.9 sf
18 % of floor area
0.4 Btu/hr-sf-F
0.35
10.6 ft
BUILDING ZONE INFORMATION
Floor
# of
# of
Cond-
Thermo-
Vent
Vent
Verified
Area
Volume
Dwell
Peop-
it-
stat
Height
Area
Leakage or. -
;one Type
--------------
(sf)
-----
(cf)
------
Units
-----
le
-----
ioned
-----
Type
--------
(ft)
-----
(sf)
-------
Housewrap
-- -------
.,IVING
Residence
1304
14648
0.49
1.5
Yes
Setback
2.0
Standard
No
)LEEPING
Residence
1355
1.3550
0.51
1.5
Yes
Setback
2.0
Standard
No
OPAQUE SURFACES
U-
Sheath-
Solar
Appendix
Frame
Area
fact-
Cavity
ing
Act
Gains
IV Location/
Surface
Type
(sf)
or
R-val
R-val
Azm
Tilt
Reference Comments.
`.,IVING
1
Door
Wood
28
0.500
0
0
315
90
Yes
IV.5 A4
2
Wall
Wood
109
0.074
19
0
0
90
Yes
IV.9 A5
3
Wall
Wood
135
0.074
19
0
0
90
No
IV.9 A5
5
Wall
Wood
440
0.074
19
0
90
90
Yes
IV.9 A5
7
Wall
Wood
213
0.074
19
0
180
90
Yes
IV.9 A5
9
Wall
Wood
125
0.074
19
0
270
90
Yes
IV.9 A5
,.1
RoofRad
Wood
1304
0.032
30
0
n/a
0
Yes
IV.1 A7
)LEEPING
4
Wall
Wood
190
0.074
19
0
0
90
Yes
IV.9 A5
6
Wall
Wood
295
0.07.4
19
0
90
90
Yes'IV.9
A5
t
'ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3
------------------------------------------
>roject Title.......... Pasa Tiempo Plan 1 Date..08/16/06 10:09:35
---------------------------------------- -
MICROPAS7 v7 10 File-PSTMPOI Wth-CTZ15S05 Program-FORM.CF-1R
User#-MP0864. User-D & R Calcs Run-Pasa Tiempo Plan 1
------------------------------------------------------------------------=-- ---
OPAQUE SURFACES
U-
Sheath-
Solar
Appendix
Frame
Area
fact-
Cavity
ing
Act
Gains
IV Location/
Surface
Type
(sf)
or
R-val
R-val
Azm
Tilt
Reference Comments
------------
8 Wall
-----
Wood
----
191
-----
0.074
-----
19
-----
0
---
180
----
90-Yes
---
-----------------------
IV.9 A5
_0 Wall
Wood
542
0.074
19
0
270
•.90
Yes
IV.9 A5
'.2 RoofRad
Wood
1355
0.032
30.
0
n/a
0
Yes
IV..1 A7
PERIMETER LOSSES
Appendix
Length
F2
Insul
Solar
IV
Location/
Surface
(ft)
Factor
R-val
Gains
Reference
Comments
------------
LIVING
------
--------
-------
-----
---------
----------------------
13
SlabEdge
127
0.730
R-0
No
IV.26 Al
SLEEPING
14
SlabEdge
120
0.730
R-0
No
IV.26 Al
FENESTRATION
SURFACES
---------------------
Exterior
Area
U-
Act
Shade
)rientation
(sf)
factor
SHGC
Azm Tilt
Type
Location/Comments
JIVING
1
Door
Front
(N)
40.0
0.400
0.350
0
90
Standard
FRONT/Vinyl/Wd Dr LoE
2
Wind
Front
(N)
18.0
0.400
0.350
0
90
Standard
FRONTI/Vinyl/Wd Op LoE
4
Wind
Left
(E)
20.0.0.4.00
0.350
90
90
Standard
LEFT/Vinyl/Wd Op LoE
5
Wind
Left
(E)
8.0
0.400
0.350
90
90
Standard
LEFTI/Vinyl/Wd Op LoE
6
Wind
Left
(E)
14.0
0.400
0.350
90
90
Standard
LEFT11/Vinyl/Wd Op LoE
8
Door
Back
(S)
80.0
0.400
0.350
180
90
Standard
BACK/Vinyl/Wd Dr LoE
9
Wind
Back
(S)
40.0
0.400
0.350.180
90
Standard
BACK1/Vinyl/Wd Op LoE
-.1
Wind
Right
(W)
50.0
0.400
0.350
270
90
Standard
RIGHT/Vinyl/Wd Op LoE
,3LEEPING
!.
3
Wind
Front
(N)
40.0
0.400
0.350
0
90
Standard
FRONT2/Vinyl/Wd Op LoE
7
Door
Left
(E)
40.0
0.400
0.350
90
90
Standard
LEFT2/Vinyl/Wd Dr LoE
-0
Door
Back
(S)
64.0
0.400
0.350
180
90
Standard
BACK2/Vinyl/Wd Dr LoE
.2
Wind
Right
(W)
15.0
0.400
0.350
270
90
Standard
RIGHT2/Vinyl/Wd Op LoE
-_3
Wind
Right
(W)
50.0
0.400
0.350
270
90
Standard
RIGHT21/Vinyl/Wd Op Lo.E
'ERTIFICATE OF
COMPLIANCE: RESIDENTIAL COMPUTER METHOD
CF-1R Page 4
)roject
Title.,.........
Pasa
Tiempo
Pl.an..l.
Date..08/16/06
----------------
10:09:35
MICROPAS7
v7.10
File-PSTMPOI
Wth-CTZ15S05
7
Program -FORM
------------
CF-1R
---------------------------------------------------------------------------
User#-MP0864
User-D &'R
Calcs
Run-Pasa Tiempo
Plan 1
OVERHANGS
---Window---
------------
Overhang ------------
Area
Left
Right
Surface
(sf)
Width
Height
------
Depth
-----
Height Extension
------ ---------
Extension.
---------
-----------
LIVING
-----
-----
1
Door
40.0
n/a
8.0.
2.0
1.5
n/a
n/a
2
Window
18.0
n/a
6.0'
8..0
1.5
n/a
n/a
4
Window
20.0
n/a
5.0
7.0
2.0
n/a
n/a
5
Window
8.0
n/a
2-0.
1.5
2.0
n/a
n/a
6
Window
14.0
n/a
4.0
1.5
2.0
n/a
n/a
8
Door
80.0
n/a
8.0
11..5
1.0
n/a
n/a
9
Window
40.0
n/a
5.0
1.5
2.0
n/a
n/a
11
Window
50.0
n/a'
5.0
.8.0
1.0
n/a
n/a
SLEEPING
7
Door
40.0
n/a
8.0
2.5
2.0
n/a
n/a
10
Door
64.0-
n/a
8.0
1.5
2.0
n/a
n/a
12
Window
15.0,
n/a
3.0
1.5
2..0
n/a
n/a
13
Window
50.0
n/a
8.0
1.5
2.0
n/a
n/a'
SLAB SURFACES
-------------
Area
Slab Type
(sf)
LIVING
Standard Slab 1304
SLEEPING
Standard Slab. 1355
HVAC SYSTEMS
Verified
Number.
Verified
Verified
Verified.Verified
Maximum
System
of
Minimum
Refrig Charge
Adequate
Fan Watt
Cooling
Type
Systems
Efficiency
EER.
or TXV
Airflow
Draw
Capacity
JIVING
Furnace
1
0.780 AFUE
n/a
n/a
n/a
n/a
n/a
ACSplit
1
13.00 SEER
No
Yes
No
No
No
;LEEPING
Furnace
1
0.780 AFUE
n/a
n/a
n/a
n/a
n/a
ACSplit
1
13.00 SEER
No
Yes
No
No
No
ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD .CF-1R Page 5
---------------
------------------------------- -
-Iroject Title...,....... Pasa Tiempo Plan 1 Date..'08/16/06 10:09:35
-----------------------------------------------------
MICROPAS7 v7 10 File-PSTMPOI Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-P.asa Tiempo Plan 1
------------------------------------------------------------------------------
HVAC SIZING
Verified
Total Sensible Design Maximum
Heating Cooling Cooling Cooling
System Load Load Capacity Capacity
Type (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr).
LIVING
Furnace 25063 n/a n/a n/a
ACSplit n%a 19536 24244 n/a
SLEEPING
Furnace .24035 n/a n/a n/a
ACSplit n/a 18467 22917 n/a
-----------------------------------------------------
Total .49098 38002 47161 n/a
Orientation of -Maximum..... Front Facing 270 deg (W)
Sizing Location............. PALM DESERT
Winter Outside Design ...... .26 F
Winter Inside Design....... 7.0 F
Summer Outside Design...... 111*F
Summer Inside -Design ....... 75 F
Summer Range .............. .,34 F
DUCT SYSTEMS
-------------
Verified.Verified Verified
System Duct Duct Duct Surface Buried
Type Location R-value Leakage Area Ducts
LIVING
Furnace Attic R-4.2 Yes No No
ACSplit Attic R-4.2, Yes No No
SLEEPING
Furnace Attic R-4.2 Yes No No
ACSplit Attic R-4.2 Yes .No No
WATER HEATING SYSTEMS
---------------------
Number Tank External
Heater in Energy Size Insulation
.'ank.Type Type Distribution Type System Factor (gal) -R-value.
1 Large Gas Recirc/Demand 1 n/a '75 R-n/a-
'ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6
-------------------------------------------------------------------------------
_)roject Title .......... Pasa Tiempo Plan 1 Date...08/16/06 10:09:35.
-----------------------------------------------
MICROPAS7 v7.10 File-PSTMPOI Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 1
-------------------------------------------------------------------------------
WATER HEATING SYSTEMS DETAIL
Standby Internal Tank
Recovery Rated Loss Insulation Pilot
System. Efficiency Input Fraction R-value Light
--------------------------------------------------------------------
1 Large 0.79 n/a 0.02 R-n/a n/a
SPECIAL FEATURES AND MODELING'ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans,"***
*** installed to manufacturer and CEC specifications, and ***.
*** verified during plan -check -and field inspection. ***
-his building incorporates a HERS verified.Refrigerant Charge test
it a HERS verified Thermostatic Expansion Valve (TXV). If a
!ooling system is not installed, then HERS verification is not necessary.
,'his building incorporates HERS verified Duct Leakage.
,his is a multiple orientation building. This printout is for the front
-'acing North.
-his building incorporates a Radiant. Barrier.
'his building incorporates a non-standard Water Heating System.
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and, ***
*** must be reported on the CF-4R installation certificate. ***
'his building incorporates a HERS verified Refrigerant Charge test
,r a HERS verified Thermostatic Expansion Valve (TXV). If a
!ooling system is not installed, then HERS verification is not necessary.
'his building incorporates HERS verified Duct Leakage. Target leakage is
-alculated and documented on the CF-4R. If the measured CFM is above the
-arget, then corrective action must be taken to reduce the duct leakage and
hen must be retested. Alternatively, the compliance calculations could be
edone without duct testing. If ducts are not installed, then HERS
..erification is not necessary.
l
;ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 7
----------------
-------------------------------------------------------------------------------
?roject Title.......... Pasa Tiempo Plan 1 Date..08/16/06 10:09;35
MICROPAS7 v7.10 File-PSTMPOI Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 1
------------------------------------------------=------------------------------
REMARKS
'Terify HVAC sizing & equipment w/Mechanical engineer/contractor.
COMPLIANCE STATEMENT
--------------------
This certificate of compliance lists the building.features and performance
specifications needed to comply with Title-24,,Parts 1 and 6 of the.
California Code of Regulations, and the administrative regulations to
implement them.' This certificate has been signed by the individual with
overall design responsibility.
DESIGNER or OWNER
Name.... Bill Currier
Company. Colbourn Currier Noll
Address. 10675 Treena Street #101
San Diego, CA 92031
Phone... (858) 695-1914
License.
DOCUMENTATION AUTHOR
Name.... Diane P. Mendoza
Company. D & R Calcs
Address. '14107 Ipava Drive
Poway, CA 92064
Phone... 858-486-9506
Signed.. Signed.. -Q lb�L
(date) te)
ENFORCEMENT AGENCY
Name....
Title'...
Agency..
Phone.
Signed.
(date)
^IANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 1
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
lroject Title.......... Pasa Tiempo Plan 1 Date..08/16/06 10:09:35
'project Address........ 5th & Madison ******* ---------------------
La Quinta *v7.10*
)ocumentation Author... Diane P. Mendoza ******* Building Permit #'
D & R Calcs
14107 Ipava Drive Plan Check / Date
Poway, CA 92064
858-486-9506 Field Check/ Date
"limate Zone............ 15 ---------------------
:ompliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc.
---------------=--------------=----=-------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOI Wth-CTZ15S05 Program -FORM MF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan l
-------------------------------------------------------------------------------
dote: Lowrise residential buildings subject to the Standards. must contain these
neasures regardless of the compliance approach used. More, stringent compliance
zequirements from the Certificate of Compliance supersede the items marked with
in asterisk (*). When this checklist is incorporated into the permit documents,
':he features noted shall be considered by all parties as minimum component
performance specifications for the mandatory measures whether they are shown
elsewhere in the documents or on this checklist only.
3UILDING ENVELOPE MEASURES
De- En-
sign- force-
n/a
er ment
�150(a): Minimum R-19 insulation in wood framed ceiling or
equivalent U-factor in metal frame ceiling
l
150(b): Loose fill insulation manufacturer's labeled R-Value
,150(c): Minimum R-13 wall insulation in wood framed walls or
equivalent U-factor in metal frame walls (does not apply
to exterior mass walls)
150(d) Minimum R-13 raised floor insulation in framed floors
or equivalent U-factor
150(e): Installation of Fireplaces, Decorative.Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable.metal or glass door covering the entire
opening of the firebox
b. Outside air intake with damper -and control, flue
damper and control
2. No continuous burning gas pilot lights allowed
i
150(f): Air retarding wrap installed to comply with Sec. 151
meets requirements specified in ACM Residential Manual
150(g): Vapor barriers mandatory in Climate Zones 14,16 only
150(1): Slab edge insulation - water absorption rate for the
insulation material without facings no greater than 0.3%,
water vapor permeance rate no greater than 2.0 perm/inch
118: Insulation specified or installed meets insulation quality
standards. Indicate type and include CF-6R form
116-17: Fenestration Products, Exterior Doors and Infiltration/
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage
2. Fenestration products (except field -fabricated) have
ZANDATORY MEASURES CHECKLIST: RESIDENTIAL
MF-1R Page 2
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
_'roject Title.......... Pasa Tiempo Plan 1 Date..08/16/06 10:09:35
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOI Wth-CTZ15S05 Program -FORM MF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 1
label with certified U-factor,- certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification
3. Exterior doors and windows weatherstripped; all joints.
and penetrations caulked and sealed
;PACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En-
.sign- force
n/a er ment
110-113: HVAC equipment, water heaters, showerheads and
faucets certified by the Energy Commission
150(h): Heating and/or cooling loads calculated in accordance
with'ASHRAE, SMACNA or ACCA
150(i): Setback thermostat on all applicable heating and/or
cooling systems
150(j): Water system pipe and tank insulation and cooling
systems line insulation
.1. Storage gas water heaters rated with an Energy Factor
less than 0.58 must be externally wrapped with insulation
having an installed thermal resistance -of R12 or greater
2. Back-up tanks for solar system, unfired storage tanks, or
other -indirect hot water tanks have R-12 external
insulation or R-16 internal and indicated on the
exterior of the tank showing the R-value
3. The following piping is insulated according to Table 150-A/B
or Equation 150-A Insulation Thickness.:
1. First 5 feet of hot and cold water pipes closest to
water heater tank, non -recirculating systems, and
entire length of recirculating sections of hot water
pipes shall be insulated to Table 150B
2. Cooling system piping (suction, chilled water, or
brine lines), piping insulated between heating source
and indirect hot water tank shall be insulated to
Table 150-B and Equation 150-A
4. Steam hydronic heating systems or hot water systems >15 psi,
meet requirements of Table 123-A
5. Insulation must be protected from damage, including that due
to sunlight, moisture; equipment maintenance and wind
6. Insulation for chilled water piping and refrigerant suction
Piping includes a vapor retardant or is enclosed entirely
in conditioned space
7. Solar water -heating systems/collectors are certified by the
Solar Rating and Certification Corporation /
150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to
meet the requirements of the CMC Sections 601, 602, 603,
604, 605 and Standard 6-5;.supply-air and return -air ducts
and plenums are insulated to a minimum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings
shall be sealed with mastic, tape, or other duct -closure
system that meets the applicable requirements of UL 181,
RANDATORY MEASURES CHECKLIST: RESIDENTIAL
MF-1R Page 3
-------------------------------------------------------------------------------
?rojec.t Title.......... Pasa Tiempo Plan 1 Date..08/16/06 10:09:35
-------=-----------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOI Wth-.CTZ15S05 .Program -FORM MF-1R
User#-MP0864 User-D & R-Calcs Run-Pasa Tiempo Plan 1
-------------------------------------------------------------------------------
UL 181A, or UL 181B, or aerosol sealant that meets the
requirements of.UL 723. If mastic or tape is used to seal
openings greater than 1/4 inch, the combination of mastic
/
and either mesh or tape shall be used
2. Building cavities, support platforms for air handlers; and
plenums defined or constructed with -materials other than
sealed sheet metal, duct board or flexible duct shall not
be used for.conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in
cavities and support platformsshall not be compressed to cause
reductions in the cross -sectional area of the duct s
3. Joints and seams of duct systems and their components
shall not be sealed with cloth backed rubber adhesive
duct tapes.unless such tape is used in combination with
_mastic and draw bands.
Exhaust fan systems have back draft or automatic dampers
.4.
5. Gravity ventilating systems serving conditioned space have
�G
either automatic or readily accessible, manually
operated dampers
/
6. Protection of Insulation. Insulation shall be protected
from damage due to sunlight, moisture, equipment mainten-
ance and wind. Cellular foam insulation shall be protected
as above or painted with a coating that is water retardant
and provides shielding from solar radiation that can cause
degradation of the material
7.-Flexible ducts cannot have porous inner cores
114: Pool and Spa Heating Systems and Equipment
1. A .thermal efficiency that complies with the Appliance
Efficiency Regulations, on -off switch mounted outside of
the heater, weatherproof operating instructions, no
electric resistance heating and no pilot light
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for future solar heating
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch
115: Gas -fired central furnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
pilot light (Exception: Non -electrical cooking appliances
with pilot < 150 Btu/hr)
118(i): Cool Roof material meets specified criteria
.tESIDENTIAL LIGHTING MEASURES
De- En-
sign- force
n/a
er ment
150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID:
contain only high efficacy lamps as outlined in Table
150-C, and do not contain a medium screw base socket
(E24/E26). Ballast for lamps 13 watts or greater are .electronic
and have an output frequency no less than 20 kHz
1ANDATORY MEASURES CHECKLIST: RESIDENTIAL
MF-1R Page 4
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
>roject Title........ . Pasa Tiempo Plan 1 Date..08/16/06 1.0:09:35
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOI Wth-CTZ15S05 Program -FORM MF-1R
User#-MP0864. User-D & R Calcs Run-Pasa Tiempo Plan 1
150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain
only high efficacy lamps as outlined in Table 150-C,
luminaire has factory installed HID ballast
150(k)2: Permanently installed luminaires in kitchens shall
be high efficacy luminaires. Up to 50 percent of the wattage,
as determined in Sec. 130(c), of permanently installed luminaires
in kitchens may be in luminaires that are not high efficacy
luminaires, provided that these luminaires are controlled
by switches separate from those controlling the high
efficacy luminaires
-50(k)3: Permanently installed luminaires in bathrooms,
garages, laundry rooms, utility rooms shall be' high.
efficacy luminaires OR are controlled by an occupant
-sensor(s) certified to comply with Section 119(d) that
does not turn on automatically or have an always on option
".50(k)4: Permanently installed luminaires located other than.
in kitchens, bathrooms, garages, laundry rooms, and utility
rooms shall be high efficacy luminaires (except closets
less than 70 ft2), OR -are controlled by a dimmer switch
OR are controlled'by an occupant sensor(s) that complies
with Section 119(d) that does not turn on automatically
or have an always on option
-5.0(k)5: Luminaires that are recessed into insulated ceilings
are approved for zero clearance insulation.cover (IC) and
are certified air tight to ASTM E283 and labeled as air
tight.(AT) to less than 2.0 CFM at 75 Pascals
.50(k)6: Luminaires providing outdoor lighting and permanently
mounted to a residential building or to other buildings on
the same lot shall be high efficacy luminaires (not in-
cluding lighting around swimming pools/water features or
other Article 680 locations) OR are controlled by occupant
sensors with integral photo control certified to comply
with. Section 119(d)
-.50(k)7: Lighting for parking lots for 8 or more vehicles shall
have lighting that complies with Sec. 130, 132, and 147.
Lighting for parking garages for 8 or more vehicles shall
have lighting that complies with Sec. 130, 131, and 146
-50(k)8: Permanently installed lighting in the enclosed, non -
dwelling spaces of low-rise residential buildings with four
or more dwelling units shall be. high efficacy luminaires OR
are controlled by an occupant sensor(s) certified to
comply with Section 119(d)
0
gVAC SIZING
----------------
HVAC
Page 1
Project Title.......... Pasa Tiempo Plan 1
Date..08/16/06 10:09:35
Project Address........ 5th & Madison
*******
-=-------------------
La Quinta
*v7.10*
)ocumentation Author... Diane P. Mendoza
*******
Building Permit #
D & R Calcs.
14107 Ipava Drive
Plan Check /
Date
Poway,.CA 92064
858-486-9506
Field Check/
Date
:limate Zone........... 15
-------------
------
:ompliance Method...... MICROPAS7 v7.10 for
2005 Standards by Enercomp,
Inc.
MICROPAS7 v7.10 File=PSTMPOI. Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs
--------------------------------------------------------------------------------
Run-Pasa Tiempo Plan 1
GENERAL INFORMATION
-------------------
Floor Area .................
2659 sf
Volume .....................
28198 cf
Front Orientation..........
Front Facing
0 deg (N)
.Sizing Location............
PALM DESERT
Latitude .............. ...
33.7 degrees
Winter Outside. Design,.....
26 F
Winter Inside Design.......
70 F
Summer Outside Design......
111 F
.Summer Inside Design.......
75 F
Summer Range...............
34 F
Interior Shading Used.......
Yes
Exterior Shading Used......
Yes
Overhang Shading Used......
Yes
Latent Load Fraction.......
0.24
HEATING AND COOLING
LOAD SUMMARY
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
23004
10507
Glazing Conduction and Solar...:.
8430
.12342
Infiltration .....................
10012
5789
Internal Gain ....................
n/a
2290
Ducts ..............................
7652
6414
Sensible Load ......................
49098
37342
Latent Load ......................
n/a
8999
Minimum Total Load
49098
46341
Note: The loads shown are only one of the criteria affecting the.selection
of HVAC equipment'. Other relevant design factors such as air flow
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
IVAC SIZING HVAC Page 2
_?roject.Title..*......... Pasa Tiempo Plan 1 Date..08/16/06 10:09:.35
MICROPAS7 v7.10 File-PSTMPOI Wth-CTZ15S05 Program-HVAC SIZING
L User#-MP0864 User-D & R Calcs Run-Pasa Tiem o Plan 1
HEATING AND COOLING LOAD SUMMARY BY -ZONE
-----------------------------------------
ZONE 'LINING'
Floor Area.............. .........
1304 sf
Volume ...........................
14648 cf
Heating
Cooling
Description
.(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
11495
5313
Glazing Conduction and Solar.....
4752
6031
Infiltration .....................
4910
2839
Internal Gain. ..... ............
n/a
1122
Ducts ............................
3906
3174
Sensible Load .............. .....
25063
18479
Latent Load...., .................
n/a
4453
Minimum Zone Load
25063
22932.
ZONE 'SLEEPING'
Floor Area....... ...........
1355 sf
Volume...... .... ..............
13550 cf
Heating
Cooling.
Description
(Btu/hr)
(Btu/hr).
Opaque Conduction and Solar......
11509
5194
Glazing Conduction and Solar.....
3678
6311
Infiltration.......... .. ......
._ 5102
2950
Internal Gain... ..................
n/a
1168
Ducts ..........................
3746
3240
Sensible Load ................ ....
24035'
18863
Latent Load....... ...............
n/a
4546
Minimum Zone Load
24035
23409
3VAC SIZING HVAC Page 3
---------------
-------------------------------
?roject Title.......... Pasa Tiempo Plan 1 Date..08/16/.06 10:09:35
-----------------=----------------------------=--------------------------------
MICROPAS7 v7.10 File-PSTMPOI Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo,Plan l
-------------------------------------------------------------------------------
GENERAL INFORMATION
-------------------
Floor Area ................. 2659 sf'
Volume ....................... 28198 cf
Front..Orientation.......... Front Facing 90 deg (E)
Sizing Location ............. PALM DESERT
Latitude ................... 33.7 degrees
Winter Outside Design ....... 26 F
Winter Inside Design....... 70 F
Summer Outside Design...... 111 F
Summer Inside Design....... 75 F
Summer Range............... 34 F
Interior Shading Used ....... Yes
Exterior Shading Used...... Yes
Overhang Shading Used....... Yes
Latent Load Fraction....... 0.24
HEATING AND COOLING LOAD SUMMARY
Heating
Cooling
Description
---------------------------------
(Btu/hr)
-----------
(Btu/hr.)
-----------
Op aque Conduction and Solar......
23004
9979
Glazing Conduction and Solar......
8430
13408
Infiltration.... ...............
10012
5789
Internal Gain ....................
n/a
2290
Ducts....... .......... ........
7652
6526
Sensible Load ....................
49098
37991
Latent Load ......................
n/a
9156
-----------
Minimum Total Load
49098
-----------
47147
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must.also be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
[VAC SIZING HVAC Page 4
Iroject Title.......... Pasa Tiempo Plan 1 Date..08/16/06 10:09:35
MICROPAS7 v7.10 File-PSTMPOI Wth-CTZ15S05 Program-HVAC-SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 1
---------------------------------------------------------------------------------
HEATING'AND COOLING LOAD SUMMARY'BY ZONE
----------------------------------------
ZONE 'LIVING'
Floor.Area.......... .............. 1304 sf
Volume.......... ............. 14648 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque.Conduction and Solar......
11495
5159
Glazing Conduction and Solar.....
4752
7116
Infiltration.....................
4910
2839.
Internal Gain ....................
n/a
1122
Ducts ... ........................
3906
3367
-----------
Sensible Load .................
25063
-----------
19602
Latent Load .......................
n/a
4724
Minimum Zone Load
25063
24327
ZONE 'SLEEPING'
Floor Area ....................... 1355 sf
Volume 13550 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
11509
.4820
Glazing Conduction and Solar..:..
3678
6292
•Infiltration.. ...................
5102
2950
Internal Gain. ...............:...
n/a
1168
Ducts..... ..... ...........
3746
3159
Sensible Load ....................
24035
18389
Latent Load., ....................
n/a
4432
Minimum Zone. Load
24035
22820
r
[VAC SIZING HVAC Page 5
------------------
-'roject Title.......... Pasa Tiempo Plan 1 Date..08/16/06 1.0:09:35
MICROPAS7 v7.10 File-PSTMPOI Wth-CTZ15S05 Program-HVAC.SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 1
------------------------------------------------------------------------------
GENERAL INFORMATION
-------------------
Floor Area... ........ 2659 sf
Volume.................... 28198 cf
Front Orientation.......... Front Facing 180 deg (S).
Sizing Location............ PALM DESERT
Latitude ................... 33.7 degrees
Winter Outside Design...... 26 F
Winter Inside Design....... 70 F
Summer Outside Design...... 111 F
.Summer Inside Design....... 75 F
Summer Range.......... ... 34 F
Interior Shading Used...... Yes
Exterior Shading Used...... Yes
Overhang Shading Used...... Yes
Latent Load Fraction....... 0.24
HEATING AND COOLING LOAD SUMMARY
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
23004
10507
Glazing Conduction and Solar.....
8430
12342
Infiltration........ ...........
10012
5789
Internal Gain ....................
n/a
2290
Ducts............. ..............
76.52
6414
Sensible Load ....................
49.098
37342
Latent Load ......................
n/a
8999
Minimum'Total Load
-----------
49098
-----------
46341
Note: The loads shown are only one of the criteria affecting the'selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment•,.oversizing safety.margin, etc., must also be
consideredit is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
r
iVAC SIZING HVAC Page 6
-------------------------------------------------------------------------------
?roject Title.......... Pasa Tiempo Plan l Date..08/16/06 10:09:35
-------------------=------------------------------------------------------=----
-------------------------------------------------------------------------------
MICROPAS7'v7.10 File-PSTMPOI Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan ,1
-------------------------------------------------------------------------------
HEATING AND COOLING LOAD SUMMARY BY ZONE
----------------------------------------
ZONE 'LIVING'
Floor Area................ ..... 1304 sf
Volume ........................... 14648 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
11495
5313
Glazing Conduction and Solar.....
4752
6031
Infiltration .....................
4910
2839
Internal Gain .................
n/a
1122
Ducts .................... ......
3906
3174
Sensible Load............. ..... .
-----------
25063
-----------
18479
Latent Load .:..................:
n/a
4454
Minimum Zone Load
25063
22933,
ZONE'SLEEPING'
Floor Area...... 1355 sf
Volume ........................... 13550 cf
Heating
Cooling
Description-
---------------------------------
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
-----------
11509
-----------
5194
Glazing Conduction and Solar.....
3678
6311
Infiltration .....................
5102
2950
Internal Gain.................
n/a
1168.
Ducts ....... ....................
3746
3240
Sensible Load .................... .
24035
18862
Latent Load ......................
n/a
4546
Minimum Zone Load
24035
23408
iVAC'SIZING HVAC Page 7
---------------
_'roject Title........., Pasa Tiempo Plan 1 Date..08/16/06 10:09:35
----------------
7
MICROPAS7 v7.10 File-PSTMPOI Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864. User-D & R Calcs Run-Pasa Tiempo Plan 1
--------------------------------------------------------------------------------
GENERAL'INFORMATION
Floor Area.. 2659 sf
Volume ..................... 28198 cf
Front Orientation.......... Front Facing 270 deg (W)
Sizing Location............ PALM DESERT
Latitude.. 33.7 degrees
Winter Outside Design...... 26 F.
Winter Inside Design....... 70 F
Summer Outside, Design...... 111 F
Summer Inside Design....... 75 F
Summer Range............. 34 F
Interior Shading Used...... Yes
Exterior Shading Used...... Yes
Overhang Shading Used...... Yes
Latent Load Fraction....... 0.24
HEATING AND COOLING LOAD SUMMARY
Heating
Cooling
Description
---------------------------------
.(Btu/hr)
-----------
(Btu/hr)
-----------
Opaque Conduction and Solar......
23004
9989
Glazing Conduction and Solar.....
. 8430
13408
Infiltration .. .. ...............
.10012
5789
Internal Gain ......................
n/a
.229.0
Ducts......... :................
7652
6527
Sensible Load.......... ........
49098
38002
Latent Load ......................
n/a
9159
Minimum Total Load
49098
47161
Note: The loads shown are only one of the criteria affecting the selection.
of HVAC equipment. Other relevant design factors such ,as air flow
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. . It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
rN
iVAC SIZING HVAC Page 8
?roject Title.......... Pasa Tiempo Plan 1 Date..08/16/06 10:09:35
------------------------------- ----------
MICROPAS7 v7.10 File-.PSTMPOl Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 1
HEATING AND COOLING.LOAD SUMMARY BY ZONE
----------------------------------------
ZONE 'LIVING'
Floor Area....... 1304 sf
Volume ............................ 14648 cf
Heating
Cooling
Description
---------------------------------
(Btu/hr)
----------=
(Btu/hr)
-----------
Opaque Conduction and Sblar......
11495
5103
Glazing Conduction and Solar.....,
4752
7116
Infiltration ......................
4910
2839
Internal Gain ....................
n/a
1122
Ducts ............................
3906
3356
Sensible Load ....................
---------=-
25063
-----------�
19536
Latent Load............... .....
n/a
4708.
Minimum.Zorie Load
25063
24244
ZONE 'SLEEPING'
Floor Area ....................... 1355 sf.
Volume ........................... 13550 cf
Heating,
Cooling
Description
(Btu/hr).
(Btu/hr)
Opaque Conduction and Solar......
11509
4885
Glazing Conduction and Solar.....
3678
6292
Infiltration ......................
5102
2950
Internal Gain.. ...............
n/a
1168
Ducts............ ..............
3746
3172
Sensible Load ....................
24035
18467
Latent Load....... ..............
n/a
4450
Minimum Zone Load
24035
229.17
PASA TIEMPO
PLAN 1 w/ CASITA
LA QUINTA, ' . CA
CLIMATE ZONE 15
D & R Calcs
Title 24 Energy Calculations
Micropas v7.10 Performance Method
August 1.6, 2006
TITLE.24 COMPLIANCE REQUIREMENTS SUMMARY
PASA Tiempo Plan 1 w/ Casita
Ceiling Insulation = R-30 min. PROVIDE RADIANT BARRIER ROOF SREATHING
(NOTE ON PLANS)
Wall Insulation = R-19 min.
Floor Insulation = N/A
Thermal Mass Areas = See floor plan
i
Glazing = All windows & doors to be dual glazed. All glass is Low E.
Glazing shall be installed with a,NFRC certifying label
attached showing Uvalue.
Solar Heat Gain Co -efficient = 0.35 windows & doors
Uval.ue 0.40 vinyl/wd windows
Owner to purchase windows & doors w/ specified Uvalues & SHGC's-or better.
Hot Water Heater = (1) 75 GAL a. o. Smith #BTC-251-*** or eq. Standby loss
2.0 min. Provide demand recirc pump.
Infiltration = Standard
AFUE - 0.78 min. SEER - 13. 0 min WITH TXV
Duct' Insulation = R-4.2 min. PROVIDE DUCT TESTING BY HERS RATER
Heater sizing
Zone 1 "LIVING" Sensible heat load - 25,063 Btu
(Verify HVAC equip. w/ Mechanical)
Zone 2 "SLEEPING" Sensible heat load,- 30,050 Btu
(Verify HVAC.equip. w/ Mechanical).
Air Conditioning -
Zone 1 "LIVING" Sensible cool'g load = 19,436 Btu
Latent cool'g load = 4,684 Btu
Zone 2 "SLEEPING" Sensible'cool'g load = 22,015 Btu
Latent cool'g load, 5,306 Btu
Verify HVAC.sizing &.equipment with a Mechanical Engineer/Contractor.
Owner may install any Make & Model HVAC equipment that is equal or greater
than the minimum efficiencies listed above. All equipment'is.listed "or eq"
:ERTIFICATE.OF
COMPLIANCE: RESIDENTIAL COMPUTER METHOD
CF-1R
Page 1
--------------------------------------=----------------------------------------
>roje.ct Title..........
Pasa Tiempo
Plan 1/Casita
Date..08/16/06 10:10:02
droject Address........
5th & Madison
*******
---------------------
La Quinta
*v7.10*
)ocument.ation Author...
Diane-P'. Mendoza
*******.
Building Permit #
D & R Calcs
14107 Ipava
Drive
Plan Check
/Date
Poway., CA. 92064
858-486-9506
Field Check/
Date
"limate Zone ...........
15
---------------------
.ompliance Method......
MICROPAS7 v7.10
for 2005
Standards
by Enercomp,
Inc.
-------------------------------------------------------------------------------
MICROPAS7
v7.10 File-PSTMPOIC
Wth-CTZ15S05
Program
-FORM CF-1R
User#-MP0864
-------------------------------------------------------------------------------
User-D & R Calcs
Run-Pasa
Tiempo
Plan 1/Casita
=
MICROPAS7
ENERGY USE SUMMARY
=
= Energy
----------------------------
Use
Standard Proposed
Compliance
_ (kTDV/sf-yr)
_-----------------------
----------
Design
----------
Design
Margin =
_ Space
Heating..........
1.94
1.93
---------- _
0.01 =
- Space
Cooling ..
67.56
65.26
2.30. _
= Water
Heating..........
8.57
8.85
-0.28 =
=
North Total
78.07
76.04
2.0.3 -
Space
Heating1.94
2.04
-0.10 =
= Space
Cooling...........
67.56
64.93
2.63 =
_ -Water
Heating..........
8.57
8.85
-0.28 =
=
East Total
78.07
75.82
2.25 =
= Space
Heating...........
1.94
2.07
-0.13 =
- Space
Cooling67.56
64.78
2'.78 _
= Water'Heating..........
8.57
8.85.
-0.28 =
=
South Total
78.07
75.70
2.37 =
= Space
Heating..........
1.94
1.97
-0.03 =
Space
Cooling..........
67.56
65.24
2.32 =
= Water
Heating..........
8.57
8.85
-0.28 =
=
West Total
.78.07
76.06
2.01 =
_ ***
Building complies
with Computer
Performance
_
*** HERS Verification
Required for
Compliance-*** _
:ERTIFICATE OF COMPLLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2
?roject Title.......... Pasa Tiempo Plan 1/Casita Date..08/16/06 10:10':02
-----------------------
------------------------------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOIC Wth-CTZ15S05 Program -FORM CF-1R L.
User#-MP.0864 User-D & R Cal.cs Run-Pasa Tiempo Plan 1/Casita
GENERAL INFORMATION
HERS Verification.......... Required
Conditioned Floor Area..... 2998 sf
Building Type.............. Single Family Detached
Construction Type New
Fuel Type NaturalGas
Building Front Orientation. Cardinal - N.,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... FullYear
Floor Construction Type....
Number of Building Zones...
Conditioned Volume..........
Slab -On -Grade Area.........
Glazing Percentage..:.......
Average Glazing U-factor...
Average Glazing SHGC.......
Average.Ceiling Height.....
Slab On Grade
2 .
31588 cf
2998 sf
16.8 % of floor area
0.4 Btu/hr-sf-F
0.35
10.5 ft
BUILDING ZONE INFORMATION
Floor
#
of
# of
Cond-
Thermo-
Vent Vent Verified
Area
Volume Dwell
Peop-
it-
stat
Height Area Leakage or
;one Type
-------------
(sf)
-----
(cf) Units
------ -----
le
-----
ioned
-----
Type.,
--------
(ft) (sf) Housewrap
----- ------- ----------
.JIVING
Residence
1304
14648
0.43
1.3
Yes
Setback
2.0 Standard No
'SLEEPING
Residence
1694
16940
0.57
1..7
Yes
Setback
2.0 Standard No
OPAQUE SURFACES
i7=
---------------
Sheath-
Solar Appendix
Frame
Area
fact-
Cavity ing
Act
Gains IV Location/
Surface
Type
(sf)
or
R-val R-val
Azm
Tilt
Reference Comments
'JIVING
1 Door
Wood
28
0.500
0
0
315
90 Yes
IV.5 A4
2 Wall
Wood
109
0..074
19
0
0
90 Yes
IV.9 A5
3 Wall
Wood
135
0.074
19
0
0
90 No
IV.9 A5
5 Wall
Wood
440
0.074
19
0
90
90 Yes
IV.9 A5
7 Wall
Wood
213
0.074
1.9
0
180
90 Yes
IV.9 A5
9 Wall
Wood
125
0.074
19
0
270
90 Yes
IV.9 A5
_1 RoofRad
Wood
1304
0.032
30
0
n/a
0 Yes
IV.1 A7
;LEEPING
4 Wall
Wood
194
0.074
19
0
0
90 Yes
IV.9 A5
6 Wall
Wood
278
0.074
19
0
90
90 Yes
'IV.9 A5
'ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3
>roject Title Pasa Tiempo.Plan 1/Casita Date..08/16/06 10:10:02
-------=---------------------------------------------------------------------=-
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOIC Wth-CTZ15S05 Program -FORM CF-iR
User#-MP0864 User-D & R-Calcs Run-Pasa Tiempo Plan 1/Casita
Surface
8 Wall
_0 Wall
,_2 RoofRad
Surface.
------------
,LIVING.
13 S1abEdge
SLEEPING
14 S1abEdge
)rientation
OPAQUE SURFACES
---------------
U- Sheath Solar Appendix
Frame Area fact- Cavity ing. Act Gains IV .Location/
Type (sf) or R-val R-val Azm Tilt Reference Comments
Wood 191 0.074 19 0 180 90 Yes IV.9 A5
Wood 730 0.074 19 0 270 90.Yes IV.9 A5
Wood 1694 0.032 30 0 n/a. 0 Yes IV.1 A7
PERIMETER LOSSES
----------------
Appendix
Length F2. Insul Solar IV Location/
(ft) Factor R-val Gains Reference.Comments
--------.------------- ------------------------------------
127 , 0.730 R-'0
180 0.730 R-0
.jIVING
1
Door.
Front
(N)
2
Wind
Front
(N)
4
Wind
Left
(E)
5
Wind
Left
(E)
6
Wind
Left
(E)
9
Door
Back
( S )
.0
Wind
Back
(S)
-'-2
Wind
Right
. (W)
_SLEEPING
3
Wind
Front
(N)
7
Door
Left
(E)
8
Door
Left
(E)
_ 1
Door
Back
( S )
,3
Wind
Right
(W)
_4
Wind
Right
(W)
No IV.26 Al
No IV.26 Al
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
(s"f) factor SHGC Azm Tilt Type Location/Comments
----- ----- ----- --- ------------------------------------
'40.0
�18.0
0.400
0.350
0
90
-Standard
FRONT/Vinyl/Wd Dr LoE
0.400
0.350
0
90
Standard
FRONTI/Vinyl/Wd Op LoE
)20.0
0.400
0.350
90
90
Standard
LEFT/Vinyl/Wd Op LoE
8.0
0.400
0.350
90
90
Standard
LEFT1/Vinyl/Wd Op LoE
✓14.0
0.400
0.350
90
90
Standard
LEFT11/Vinyl/Wd Op LoE
A80.0
0.400
0.350
180
90
Standard
BACK/Vinyl/Wd Dr LoE
�40.0
0*.400
0.350.180
90
Standard
BACK1/Vinyl/Wd Op LoE
50.0
0.400
0.350
270
90
Standard,
RIGHT/Vinyl/Wd Op LoE
46.0
0.400
0.350
0
90
Standard
FRONT2/Vinyl/Wd Op LoE
V40.0
0.400
0.350
90
90
Standard
LEFT2/Vinyl/Wd Dr LoE
120.0
0.400
0.350
90
90
Standard
LEFT21/Vinyl/Wd Dr.LoE
✓64.0
0.400,0.350
180
90
Standard
BACK2/Vinyl/Wd Dr LoE
15.0
0.400
0.350
270
90
Standard
RIGHT2/Vinyl/Wd Op LoE
50.0
0.400
0.350
270
90
Standard
RIGHT21/Vinyl/Wd Op LoE,
,ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4
?roject Title...:...... Pasa Tiempo Plan 1/Casita Date..08/16/06 10:10:02
' MICROPAS7 v7.10 -File-PSTMPOIC' Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 1/Casita
-----=------------------------------------------------------------------------
OVERHANGS
---Window--- -----------
-Overhang -------
-----
Area
Left
Right
Surface
(sf)
Width
Height Depth
Height Extension
Extension
LIVING.
1
Door
40.0
n/a
8.0 2.0
1.5
n/a
n/a
2
Window
18.0
n/a
6.0 8.0
1.5
n/a
n/a
4
Window
20.0
n/a
5.0 7.0.
.2.0
n/a
n/a
5
Window
8.0
n/a
2.0 1.5
2.0
n/a
n/a
6
Window
14.0
n/a
4.0 1.5
2.0
n/a
n/a
9
Door
80.0,
n/a
8.0 11.5
1.0
n/a
n/a
10
Window
.40.0
n/a
5.0 1.5
2.0
n/a
n/a
12
Window
50.0
n/a
5.0 8.*0
1.0
n/a
n/a
SLEEPING
7
Door
40.0
n/a
8.0 2.5
2.0
n/a
n/a
8
Door
20.0
n/a
8.0 7.0
2:0.
n/a
n/a
11
Door
64.0
n/a.
8.0 1.5
2.0
n/a
n/a.
13
Window
15.0
n/a'
3.0 1.5
2.0
n/a.
n/a
14
Window
50.0
n/a
8.0 1._5
2.0
n/a
n/a
SLAB SURFACES
------------
Area
Slab Type
(sf)
LIVING
Standard
Slab
1304
SLEEPING
Standard
Slab
1694
HVAC SYSTEMS
------------
Verified
Number
Verified
Verified
Verified
Verified
Maximum
System
-of
Minimum
Refrig Charge
Adequate
Fan Watt
Cooling
Type
Systems
Efficiency
EER
or TXV
Airflow
Draw
Capacity
------------
-------
-----------
JIVING
Furnace
1
0.780 AFUE
n/a
n/a
n/a
n/a
n/a
ACSplit
1
13.00 SEER
No
Yes
No
No
No
SLEEPING
Furnace
1
0.780 AFUE
n/a
n/a
n/a
n/a
n/a
ACSplit
1
13.00 SEER
No
Yes
No
No
No
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5
------------------
?roject.Title.......... Pasa Tiempo Plan l/Casita Date..08/16/06 10:'10:02
------ ---------------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOIC Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calc.s Run-Pasa Tiempo Plan 1/Casita
HVAC SIZING
Verified
Total
Sensible
Design
Maximum
Heating
Cooling
Cooling
Cooling
System
Load
Load
Capacity
Capacity
Type
-------------
(Btu/hr)
----------
(Btu/hr)
----------
(.Btu/hr)
--------- ----------
(Btu/hr)
LIVING
-
Furnace
25063
n/a
n/a
n/a
ACSplit
h/a
19370
.24038
n/a
SLEEPING
Furnace
30050
n/a
n/a
n/a
ACSplit
n/a
21382
26535
n/a
-------------
Total
----------
55113
----------
40752
--------------------
50573
n/a
Orientation of
Maximum.....
Front Facing
270 deg (W)
Sizing
Location............
PALM DESERT
Winter
Outside
Design......
26 F
Winter
Inside'Design.......
70 F
Summer
Outside
Design......
111 F
Summer
Inside Design.......
75 F
Summer
Range...............
34 F
System
Type
LIVING
Furnace
ACSplit
SLEEPING
Furnace
ACSplit
DUCTSYSTEMS
-
Verified Verified Verified
Duct Duct Duct Surface Buried
Location R-value Leakage Area Ducts
Attic
R-.4.2
Yes
No
Attic
R-4.2
Yes
No
Attic
R-4.2,
Yes
No
Attic
R-4.2
Yes
No
Heater
-'ank Type Type
---------------------=-
1 Large Gas
WATER HEATING SYSTEMS
---------------------
Number
in Energy
Distribution Type System Factor
------------------- --------------
Recirc/Demand 1 n/a
No
No
No
No
Tank
External
Size
Insulation
(gal)
R-value
------
75
----------
R-n/a
_'ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6
7-7
3roject Title........... Pasa Tiempo Plan 1/Casita Date..08/16/06 10:10:02
----------------------------------------------------=--------------------------
---------------------7-7-------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOIC Wth-CTZ15S05. Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 1/Casita
-------------- ----------------------------------------------------------------
WATER HEATING SYSTEMS DETAIL
Standby Internal Tank
Recovery Rated Loss Insulation Pilot
System Efficiency Input Fraction R-value Light
--------------------------------------------------------------------
1 Large 0.79 n/a 0.02 R-n/a n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
***,installed to manufacturer and CEC specifications, and **.*
*** verified during plan check and field inspection. ***
-his.building incorporates a HERS verified Refrigerant Charge test
jr a HERS verified Thermostatic Expansion Valve (TXV). If a
:ooling system is not installed, then HERS verification is not necessary.
'his building incorporates HERS verified Duct Leakage.
This is a multiple orientation building. This printout is for the front
:acing North.
-his building incorporates a Radiant Barrier.
'his building incorporates a non-standard Water Heating System.
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
***.verification by a certified home energy rater under_ ***
***.the supervision of a CEC-approved HERS provider using ***
*** CEC. approved testing and/or verification methods and ***
*** must be reported on the CF-4R installation certificate. ***
this building incorporates a HERS verified Refrigerant Charge test
)r a HERS verified Thermostatic Expansion Valve (TXV). If a
:ooling system is not installed, then HERS verification is not necessary.
'his building incorporates HERS verified Duct Leakage. Target leakage is
calculated and documented on the CF-4R. If the measured CFM is above the
`arget, then corrective action must be taken to reduce the duct leakage and
:hen must be retested. Alternatively, the compliance calculations could be
-edone without duct testing. If ducts are not installed, then HERS
verification is not necessary.
'ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 7
----------
'roject.Title.......... Pasa Tiempo Plan 1/Casita Date..08/16/06 10:10:02
MICROPAS7 v7.10 File-PSTMPOIC 'Wth-CTZ15805 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 1/Casita
REMARKS
"erify.HVAC sizing & equipment w/ Mechanical engineer/contractor.
COMPLIANCE STATEMENT
This certificate of compliance lists the buil'ding•features and performance.
specifications needed to comply with Title-24, Parts 1 and 6 of the
California Code of Regulations, and.the administrative regulations to
implement them. This certificate has.been signed by the individual with
overall design responsibility.
DESIGNER -or OWNER DOCUMENTATION AUTHOR
Name..'.:, Bill Currier Name.... Diane P. Mendoza
Company. Colbourn Currier Noll Company. D & R Calcs
Address. 10675 Treena Street #101 Address. 14107 Ipava Drive
San Diego, CA 92031 Poway, CA 92064
Phone.'.. (858) 695-1914' Phone... 858-486-9506'
License.
Signed.. Signed.,. :"0("
(date) date)
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed..
(date)
-V.ANDATORY MEASURES CHECKLIST: RESTDENTIAL MF-1R Page 1
----------------
----
project Title........... Pasa Tiempb Plan 1/Casita Date...08/16/06 10:10:02
9roject Address........ 5th & Madison ******* ---------------------
La Quinta *v7.10*
Documentation Author... Diane P. Mendoza ******* Building Permit #
D & R Calcs
14107 Ipava Drive Plan Check / Date
Poway., CA 92064
858-486-9506 Field Check/ Date
_"limate Zone........... 15 ---------------------
-ompliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc.
--------------------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOIC Wth-CTZ15S05 Program -FORM MF-1R
User#-MP0864 User=D & R Calcs Run-Pasa Tiempo Plan 1/Casita
-------:------------------------------------------------------------------------
Jote: Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. More stringent compliance
-equirements from the Certificate of Compliance supersede the items marked with
in asterisk (*). When this.checklist is incorporated into the permit documents,.
:he features noted shall be considered by all parties as minimum component
?erformance. specifications for the mandatory.measures whether they are shown
elsewhere in the documents or on this checklist only.
.3UILDING ENVELOPE MEASURES
n/a
,150(a) Minimum R-19 insulation in wood framed ceiling or
equivalent U-factor in metal frame ceiling
150(b): Loose fill insulation manufacturer's labeled R-Value
�150(c):. Minimum R-13 wall insulation in wood framed walls or
equivalent U-factor in metal frame walls (does not apply
to exterior mass walls)
,150(d): Minimum R-13 raised floor insulation in framed floors
or equivalent U-factor
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
l..Masonry and factory -built fireplaces have:
a. Closeable metal or glass door covering the entire
. opening of the firebox
b. Outside air intake with damper.and control, flue
damper and.control
2. No continuous burning gas' pilot lights allowed
150(f): Air retarding wrap .installed to comply with Sec. 151
meets requirements specified in ACM Residential Manual
150(g) Vapor barriers mandatory in Climate Zones 14,16,only �G
150(1): Slab edge insulation - water absorption rate for the
insulation material without facings no greater than 0.3%,
water vapor permeance rate no greater than 2.0 perm/inch
118: Insulation specified or installed meets insulation quality
standards. Indicate type and include CF-6R form
116-17: Fenestration Products, Exterior Doors and Infiltration/
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage
2. Fenestration products (except field -fabricated) have
De- En-
sign- force-
er ment
i
l
Z
4ANDATORY MEASURES CHECKLIST: RESIDENTIAL
MF-1R Page .2
-------------------------------------------------------------------------------
?roject Title.......... Pasa Tiempo Plan 1/Casita. Date..08/16/06 10:10:02
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOIC Wth-CTZ15S05 Program -FORM MF-1R
User#-MP0864 User-D & R Cal'cs Run-Pasa Tiempo Plan 1/Casita
-----------------------------------------------------------------------------
label with certified U-factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed .
SPACE CONDITIONING, WATER,HEATING AND PLUMBING SYSTEM MEASURES De En-
sign- force
n/a er ment
110-113: HVAC equipment, water heaters, showerheads and
faucets certified by the Energy Commission
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA _
150(i): Setback thermostat on all applicable heating and/or
cooling systems
150(j): Water system pipe and tank insulation and cooling
systems line insulation
1. Storage gas water heaters rated with an Energy Factor
less than 0.58 must be externally wrapped with insulation
having an installed thermal resistance of R12 or greater_
2. Back-up tanks for solar system, unfired storage tanks, or
other indirect hot water tanks have R-12 external
insulation or R-16 internal and indicated on the
exterior of the tank showing the R-value
3. The following piping is insulated according to Table
or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest
150-A/B
to
water heater tank, non -recirculating systems, and
entire length of recirculating sections of hot water
pipes shall be.insulated to Table 150B
2. Cooling system piping (suction, chilled water, or
brine lines), piping insulated between heating source
and indirect hot water tank shall be insulated to
Table 150-B and Equation 150-A
4. Steam hydronic heating systems or hot-water systems >15 psi
Meet requirements of Table 123-A
5. Insulation must be protected from damage, including that due
to sunlight, moisture, equipment maintenance and wind
6. Insulation for chilled water piping and refrigerant suction
piping includes a vapor retardant or is enclosed entirely
in conditioned space
7. Solar water -heating systems/collectors are certified by the
Solar Rating and Certification Corporation
7150 (m) Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to
meet the requirements of the CMC Sections 601, 602, 603,
604, 605 and Standard 6-5; supply -air and return -air ducts
and plenums are insulated to a minimum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings
shall be sealed with mastic, tape, or other duct -closure
system that meets the applicable requirements of UL.181,
4ANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R
Page,3
?roject Title.......... Pasa Tiempo Plan 1/Casita Date..08/16/06 10:10:02
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOIC Wth-CTZ15505 Program -FORM MF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 1/Casita
----------------------------------------------------------------7--------------
UL 181A, or UL 181B or aerosol sealant that meets the
requirements of UL 723. If mastic or tape is used to seal
openings greater,than 1/4 inch, the combination of mastic
and either mesh or tape shall be used
2. Building cavities, support platforms for air handlers, and
plenums defined or constructed with materials other than
sealed sheet metal, duct board or flexible duct shall not
be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in
cavities and support platforms shall not be compressed to cause
reductions=in the cross -sectional area of the ducts
3. Joints and seams of duct systems and their components
shall not be sealed with cloth backed rubber adhesive
duct.tapes unless such tape is used in combination with /
mastic and draw bands
4. Exhaust fan systems have back draft or automatic dampers
5. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
operated dampers
6. Protection of Insulation. Insulation shall be protected
from damage due to sunlight, moisture, equipment mainten-
ance and wind. Cellular foam insulation shall be protected
as above or painted with a coating that is water retardant
and provides shielding from solar radiation that can cause j
degradation of the material
7. Flexible ducts cannot have porous inner cores
114: Pool and Spa Heating Systems and Equipment '
1. A thermal efficiency that complies with the Appliance
Efficiency Regulations, on -off switch mounted outside of
heater, weatherproof operating instructions, no
.the
electric resistance heating and no pilot light �
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for future solar heating
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch
115: Gas -fired central furnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
pilot light (Exception:'Non-electrical cooking appliances /
with pilot < 150 Btu/hr)
118(i): Cool Roof material meets specified criteria
-ZESIDENTIAL LIGHTING MEASURES De-
En-
sign-
force
n/a er
ment
150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID:
contain only high efficacy lamps as outlined in Table
150-C, and do not contain a medium screw base.socket /
(E24/E26). Ballast for lamps 13 watts or greater are electronic
and have.an output frequency no less than 20 kHz
MANDATORY MEASURES CHECKLIST: RESIDENTIAL
MF-1R Page 4
-----------------------=-------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Pasa Tiempo Plan 1/Casita Date..08/16/06 10:10:02
--------------------------------------------------------------=----------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOIC Wth-CTZ15S05 Program -FORM MF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan l/Casita
150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain
only high efficacy lamps as outlined.in.Table 150-C,
luminaire has factory installed HID. ballast•
150(k)2: Permanently installed luminaires in kitchens shall
be high efficacy luminaires. Up to 50 percent of the wattage,
as determined in Sec. 130(c), of permanently installed luminaires
in kitchens may.be in luminaires that are not high efficacy
luminaires, provided that these luminaires are controlled
by switches separate from those controlling the high
efficacy luminaires
L50(k)3: Permanently installed luminaires in bathrooms,
garages, laundry rooms, utility rooms shall be high
efficacy luminaires OR are controlled by an occupant
sensor(s) certified to comply with Section 119(d) that
does not turn on automatically or have an always on option
150(k)4: Permanently installed luminaires located other than
in kitchens, bathrooms, garages, laundry rooms, and utility
rooms shall be high efficacy luminaires (except closets
less than 70 ft2), OR are controlled by a dimmer switch
OR are controlled by an occupant sensor(s) that complies
with Section 119(d) that does not turn on automatically
or have an always on option
150(k)5: Luminaires that are recessed into insulated.ceilings
are approved for zero clearance insulation cover (IC) and
are certified air tight to ASTM E283 and labeled as air
tight (AT) to less.than 2.0 CFM at 75 Pascals
L50(k)6: Luminaires providing outdoor lighting and permanently
.mounted to a residential building or to other buildings on
the same lot shall be high efficacy luminaires.(not in-
cluding lighting around swimming pools/water features or
.other Article 680 locations) OR are controlled by occupant
sensors with integral photo control certified to comply
with Section 119(d)
150(k)7: Lighting for parking lots for 8 or -more vehicles shall
have lighting that complies with Sec. 130, 132, and 147.
Lighting for parking garages for 8 or more vehicles shall.
have lighting that complies with Sec. 130, 131, and 146
150(k)8: Permanently installed lighting in the enclosed, non -
dwelling spaces of low-rise residential buildings with four
or more dwelling units shall be high efficacy luminaires OR /
are controlled .by an occupant sensor(s) certified to
comply with Section 119(d)
gVAC SIZING HVAC Page 1
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
?roject Title.......... Pasa Tiempo Plan 1/Casita Date..08/16/06.10:10-:02
"roject Address........ 5th & Madison ******* ---------------------
La Quinta *v7.10*
)ocumentation Author... Diane P. Mendoza ******* Building Permit #
D & R Calcs
14107 Ipava Drive Plan Check / Date
Poway, CA 92.064
858-486-9506 Field Check/ Date
21imate Zone......... 15 ---------------------
Method ....... MICROPAS.7 v7.10 for 2005 Standards.by Enercomp, Inc.
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOIC Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 1/Casita
-------------------------------------------------------------
GENERAL INFORMATION
-------------------
Floor Area ...........:.....
Volume.......
Front Orientation..........
Sizing Location............
Latitude ...................
Winter Outside Design......
Winter Inside Design.......
Summer Outside Design......
Summer Inside Design.......
Summer Range.. ...........
Interior Shading Used......
Exterior Shading Used......
Overhang Shading Used......
Latent Load Fraction.......
2998 sf
31588 cf
Front Facing 0 deg (N)
PALM DESERT
33.7 degrees
26 F
70 F
111 F
75 F
34 F
Yes
Yes
Yes
0.24
HEATING AND COOLING LOAD SUMMARY
r
Description
----- 7----- 7---------------------
Opaque Conduction and Solar......
Glazing Conduction and Solar.....
Infiltration ......................
Internal Gain ....................
Ducts.............................
Sensible Load ....................
Latent Load. .....................
Heating Cooling
(Btu/hr) (Btu/hr)
----------------------
26348
11497
8888
13087
11288
6527
n/a
2290
8589
6927
55113 40328
n/a 9719
----------- --------
Minimum Total Load 55113 50047
Note: The loads shown are only one of the criteria affecting the selection
of. HVAC equipment. Other relevant design factors such as air flow
requirements, outside air, outdoor design temperatures, coil. sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. - It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
IVAC SIZING HVAC Page 2
?roject Title .......... Pasa Tiempo Plan 1/Casita Date..08/16/06 10:10:02
__ __---------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOIC Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 -User-D & R Calcs Run-Pasa Tiempo Plan 1/Casita
HEATING AND COOLING LOAD SUMMARY BY ZONE .
------------------------------- - --------
ZONE 'LIVING'
Floor Area .................... 1304 sf-
Volume......................... 14648 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and.Solar......
11495
5313
Glazing Conduction and Solar.....
4752
6031
Infiltration...... ..... .......
4910
2839
Internal Gain ....................
n/a
985
Ducts..... ...................
3906
3146
Sensible Load............. ......
25063
18313
Latent Load ........ I...............
n/a
.4413
Minimum Zone Load
25063
22726
ZONE 'SLEEPING'
Floor Area ............:..........
1694 sf
Volume ...........................
16940 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
14852
6184_
Glazing Conduction 'and Solar......
4136
7056
Infiltration.,..... ..........
6378
3688
Internal Gain:..... ..............
n/a
1305
Ducts ........:.......
4683
3781
Sensible Load .....................
30050
22015
Latent.Load......................
n/a
5306
Minimum Zone Load
30050
27321
[VAC SIZING HVAC Page 3
---------------------------------------------------------------------------=---
-------------------------------------------------------------------------------
?roject Title........... Pasa Tiempo Plan !/Casita Date..08/1'6/06 10:10:02
-----------------
MICROPAS7 v7.10 File-PSTMPOIC Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 1/Casita
------------------------------•------------------------------------------------
GENERAL INFORMATION
--------------------
Floor Area.............:...
2998
sf
Volume .....................
31588
cf
Front Orientation..........
Front
Facing 90 deg (E)
Sizing Location............
PALM
DESERT -
Latitude ...................
33.7
degrees
Winter Outside Design:.....
26 F
Winter Inside*Design..:....
70 F
Summer Outside Design......
111.F
Summer Inside Design.......
75 F
Summer Range......... ....
34 F
Interior Shading Used......
Yes.
Exterior Shading Used......
Yes
Overhang Shading Used......
Yes
Latent Load Fraction.......
0.24
HEATING AND COOLING LOAD SUMMARY
Heating
Cooling
Description
---------------------------------
(Btu/hr)
-----------
(Btu/hr)
Opaque Conduction and Solar.....:.
26348
-----------
10817
Glazing Conduction and Solar.....
8888
14055
Infiltration .. ..................
11288
6527
Internal Gain. ....................
n/a
2290 .
Ducts....... *.....................
8589
6987
Sensible Load ....................
55113
40675
Latent Load ......................
n/a
9803
Minimum Total Load
55113
50478
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant. design factors such as air flow
requirements, outside "air, outdoor design temperatures, coil sizing,
availability of equipment,..oversizing safety margin, etc., must also be
considered. It is -the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
iVAC SIZING HVAC Page.4
-------------
?roject Title.......... Pasa Tiempo Plan l/Casita Date..08/16/06,10:10:0.2
MICROPAS7 v7.10 File-PSTMPOIC Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R-Calcs Run-Pasa Tiempo Plan 1/Casita
'HEATING AND COOLING LOAD SUMMARY BY ZONE
ZONE 'LIVING'
Floor Area... ...... ........ 1304 sf
Volume ........................... 14648 cf
Heating Cooling
Description (.Btu/hr) (Btu/hr)
Opaque Conduction and Solar...... 11495 5159
Glazing Conduction and Solar..... 4752 7116.
Infiltration.... 4910 2839
Internal Gain :.................... n/a 985
Ducts...... ......... 3906 3339
Sensible Load.......:. ......... 25063 19436
Latent Load..... ...... n/a 4684,
Minimum Zone Load 25063 2412.1
ZONE 'SLEEPING'
Floor Area ....................... 1694 sf
Volume. ............................ 16940 cf
Heating
Cooling
Description
(Btu/hr)
.(Btu/hr)
Opaque Conduction and Solar......
14852
5659
Glazing Conduction and Solar....,.
4136
6939
Infiltration.. .... .........
6378
3688
Internal Gain... .... .........
n/a
1305
Ducts ............................
.4683'
3648
Sensible Load.......... ........
30050
21239
Latent Load ........................
n/a
5119
Minimum Zone Load
30050
26357
-IVAC SIZING HVAC Page 5
------------------------
?roject.Title......I.... Pasa Tiempo Plan 1/Casita Date..08/16/06 10:10:02
MICROPAS7 v7.10 File-PSTMPOIC Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 1/Casita
GENERAL INFORMATION
Floor Area .................
2998 sf
Volume ......................
31588 cf
Front Orientation..........
Front Facing
180 deg (S)
Sizing Location............
PALM DESERT
Latitude ...................
33.7 degrees
Winter Outside Design......
26 F
Winter Inside Design.......
70 F
Summer Outside Design.......
-111 F
Summer Inside Design ........
75 F
Summer Range................
34 F.
Interior Shading Used .......
Yes
Exterior Shading Used......
Yes
Overhang Shading Used......
Yes
Latent Load Fraction.......
0.24
HEATING AND COOLING.LOAD
SUMMARY
---------------------------------
Heating
Cooling
Description
---------------------------------
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
----------------------
26348
11498
Glazing Conduction and Solar......
8888
13087
Infiltration .....................
11288
.6527
Internal Gain ....:..............:
n/a
2290
Ducts ...............................
8589
69:27
Sensible Load......... .. ....
55113
40329
Latent Load ......................
n/a
9719
Minimum Total Load
55113'
50048
Note:'The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as .air flow
requirements, outside air,.outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
iVAC SIZING HVAC Page 6
?roject .Title:...:..:... Pasa Tiempo Plan 1/Casita Date..08/16/06 10':10:02
MICROPAS7 v7.10 File-PSTMPOIC Wth-CTZ15S05 Program-H-VAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 1/Casita
HEATING AND COOLING LOAD SUMMARY BY ZONE
--------------------------------------
ZONE 'LIVING'
Floor Area.. ....................... 1304 sf
Volume .................... ..... 14648 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
11495
5313
Glazing Conduction and Solar.....
4752
6031
Infiltration........ .........
4914
2839
Internal Gain.........,. ....
n/a
985
Ducts . ............. ............
3906'
3146
Sensible Load .................... .
25063
18313
Latent Load ......................
n/a
4414,
Minimum Zone Load
25063
22727
ZONE 'SLEEPING'
Floor Area ........................ 1694 sf.
Volume ........................... 16940 cf
Heating
Cooling
`Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
14852
6185
Glazing Conduction and Solar.....
4136
7055
Infiltration.. ............... .
6378
3688
Internal Gain ......................
n/a
1305
Ducts ............................
4683
3781
Sensible Load ....................
30050
22015
Latent Load ....:.................
n/a
5306
Minimum Zone Load
30050
27321
iVAC SIZING HVAC Page 7
-------------------------------------------------------------------------------
?roject Title........... Pasa,Tiempo Plan 1/Casita Date..08/16/06 10:10:02
MICROPA S7 v7.10 File-PSTMPOIC Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan l/Casita
GENERAL INFORMATION
Floor Area ................. 2998 sf
Volume... ........... 31588 cf
Front Orientation........... Front.Facing 270 deg (W)
Sizing Location............ PALM DESERT
Latitude. 33.7 degrees
Winter Outside Design...... 26 F
Winter Inside Design....... 70 F
Summer Outside Design...... 1.11 F .
Summer Inside Design....... 75 F
Summer Range...... 34 F
Interior Shading Used......, Yes
Exterior Shading Used...... Yes
Overhang Shading Used...... Yes.
'Latent Load Fraction........ 0.24
HEATING AND COOLING LOAD SUMMARY
Heating
Cooling
Description
---------------------------------
(Btu/hr)
-----------
(Btu/hr)
Opaque Conduction and Solar::....
26348
-----------
10882
Glazing Conduction and Solar.....
8888*
14054
Infiltration........... ........
11288 -
6527
Internal Gain ....................
. .n/a
2290
Ducts.....'............
8589
7.000
Sensible Load... ...............
55113
40752
Latent Load..... .................
n/a
9821
Minimum Total Load
-----------
55113
-----------
50573
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors.such as air -flow--
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin., etc., must also be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
1
IVAC SIZING HVAC Page 8
?roject Title.......... Pasa Tiempo Plan 1/Casita Date..08/16/06 10:10:02
-------------------------------=---------------------=-------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-PSTMPOIC Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864, User-D &'R Calcs Run-Pasa Tiempo Plan 1/Casita,
HEATING AND COOLING LOAD SUMMARY BY ZONE
ZONE 'LIVING'
Floor Area ....................... 1304 sf
Volume ........................... 14648 cf
Heating
Cooling
Description
(Btu/hr).
(Btu/hr)
Opaque Conduction and Solar......
.11495
5103
Glazing Conduction and S.olar.....
. 4752
7116
Infiltration ......................
4910
2839
Internal Gain ....................
n/a
985
Ducts.......... ................
3906
3327.
Sensible Load— .............
25063
19370
Latent Load. ...................
n/a
4668.
Minimum Zone Load
25063
24038
ZONE 'SLEEPING'
Floor Area........... 1694 sf
Volume ........................... 16940 cf
Heating
Cooling
Description
---------------------------------
(Btu/hr)
(Btu/hr)'
Opaque Conduction and Solar......
-----------
14852
- ---------
5778
Glazing Conduction and Solar.....
4106
6938
Infiltration ....................
6378
3688
Internal Gain....................
n/a
1305
Ducts .... :....................... ..
4683
3673
Sensible Load .....................
30050
21382
Latent Load ......................
n/a
5153
Minimum Zone Load
30050
26535
D & R Calcs
4
Title.24 Energy Calculations D & R Calcs
Micropas v7'.20..Performance' Method (858) 4186-'9506
April.4, 200.7
TITLE.24 COMPLIANCE REQUIREMENTS SUMMARY
Pasa Tiempo Plan'2
Ceiling Insulation = •R-30 min. PROVIDE RADIANT BARRIER ROOF. SHT'G
(NOTE ON PLANS)'
Wall' Insulation R-19 min.
Floor Insulation _ N/A
Thermal Mass Areas = See Floor plan.
Glazing All windows & doors to be dual ,glazed. All glass is Low E.
Glazing.shall be installed with a NFRC certifying label
attached showing Uvalue•:
Solar Heat Gain Co efficient = 0.35 dual windows, doors
Uvalue = 0.40 vinyl/wd windows & doors
Owner to purchase windows & doors wl specified Uvalues'& SHGC's or better.
Hot Water Heater _ (1) 75 gal A.O.Smith #BTC-2517.*** or eq. Standby
loss is 2.0 min. Provide a recirc pump.
Infiltration = Standard
AFUE - 0 .• 78 min. SEER - 13. 0 min.. WITH TXV
Duct Insulation . = R-4.2 min. PROVIDE DUCT TESTING BY HERS RATER
Heater sizing
Zone 1 "LIVING" Sensible heat load - 28;370 Btu
(verify HVAC equip. w/ Mechanical)
Zone 2 "SLEEPING" Sensible heat load-,25,077 Btu
(verify HVAC equip. w/ Mechanical)
A/C Sizing
Zone 1 "LIVING" Sensible _cool'g load 20,225 Btu
Latent cool'g load = 4,874 Btu
Zone-2 "SLEEPING Sensible cool'g load = 19,42.9•Btu
Latent.cool'g load = 4,682 Btu
Verify HVAC sizing & equipment with a Mechanical Engineer/Contractor..
Owner may install any Make & Model HVAC equipment.that is equal or'greater
than the minimum efficiencies listed above. All equipment is listed"or eq"
-'ERTIFICATE OF COMPLIANCE: RESIDENTIAL.COMPUTER
METHOD CF-lR
Page 1
?roject Title..........
Pasa Tiempo Plan 2'
Date..04/04/07 10:02:56
project Address.........
5th & Madison
******* ---------------------
La Quinta
*v7.20*
)ocumentation Author...
Diane P..Mendoza
*******
Building Permit #
D & R Calcs
14107 Ipava Drive
Plan Check /
Date
Poway, CA 92064
858-486-5506
Field Check/
Date
'limate Zone...........
15
-------.--------------
.ompliance Method.......
MICROPAS7 v7.20 for 2005
Standards by Enercomp,
Inc.
-------------------------------------------------------------------------------
MICROPAS7 v7.20
File-PSTMP02R Wth-CTZ15S05
Program -FORM CF-1R
User#-MP0864
-------------------------------------------------------------------------------
User-D & R Calcs Run-Pasa
Tiempo Plan.2
----------------------------
----------------------------
MICROPAS7 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed . Compliance =
= .(kTDV/sf-yr)
Design
Design
Margin. _
= Space
Heating...........
2.05
2.09
=0..04 =
= Space
Cooling...........
68.30
67.68
0.62 _
Water
Heating..........
9.01
9.30
-0.29 _
=
North Total
79.36
79.07
0.29 =
= Space
Heating.. .......
2.05
2.26'
-0.21 _
= Space
-Cooling ........
68.30,
65.77
2.53 =
= Water
Heating..........
9.01
9.30
-0.29 _
=
East Total
79.36
77.33
. 2.03 =
= Space
Heating..........
2.05
2.24
-0.19 =
= Space
Cooling...........
.68.30
66.45
1.85. _
= Water
Heating.....!....
9.01
9.30
-0.29 _
South Total
79.36
77.99
1.37 =
_ Space
Heating..........
2.05
1.93
0.12 =
- Space
Cooling..........
68.30
66.42
1.88 =
= Water
Heating..........
9.01
9.30
-0.29 =
=
West Total
79.36
77.65
1.71 =
_ ***
Building complies
with Computer Performance
_
***.HERS Verification
Required
for Compliance
*** _
I
'ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF--1R Page 2
?roject Title.......... Pasa Tiempo Plan 2.'. Date..04/04/07 10:02:56
MICROPAS7 v7 20 File-PSTMPO2R Wth-CTZ15S'05. Program -FORM CF-1R
User#-MP08'64 User-D & R Calcs Run-Pasa Tiempo Plan 2
-------------------------------------------------------------------------------
GENERAL INFORMATION
-------------------
HERS Verification.......... Required
Conditioned Floor Area..... 2851 sf
Building Type........... Single Family Detached
Construction Type ......... New
Fuel Type ................. NaturalGas
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units:... 1
Number'of Building Stories. 1
Weather Data Type.......... FullYear
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U-factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Slab On Grade
2
29839 cf
2851 .s.f
16.2 % of floor area
0 .'4 Btu/hr-sf -F
0.35
10.5 ft
BUILDING ZONE INFORMATION
Floor
# of
# of
Cond-
Thermo-
Vent
. Vent
Verified
Area
Volume
Dwell
Peop-
it-
stat
Height
Area
Leakage or
7one.Type
(sf)
(cf)
Units
le
ioned
Type
--------
(ft)
-----
(sf)'
-------
Housewrap
----------
--------------
IjIVING
-----
------
-----
-----
-----
Residence
1541
16739
0.54
1.6
Yes
Setback
2.0
Standard
No
SLEEPING
Residence
1310
13100
0.46
1.4
Yes
Setback
2:0
Standard
No
OPAQUE SURFACES
U-
Sheath-
Solar.
Appendix
Frame
Area
fact-
Cavity
ing
Act
Gains
IV Location/
Surface
Type
(sf)
or
R-val
R-val
Azm
Tilt
Reference Comments
------------
�IVING
-----
----
-----
-----
-----
---
----
---
-----------------------
1
Door
Wood
28
0.500
0
0
315
-.90
Yes
IV.5 A4
2
Wall
Wood
117
0.074
19
0
0
90
Yes
IV.9 A5
3
Wall
Wood
230
0.074
19
0
0
90
No
IV.9 A5
5
Wall
Wood
392
0.074
19
0
.90
90
Yes
IV.9 A5
6
Wall
Wood
150
0.074
19
0
90,
90
No
IV:9 A5
8
Wall
Wood
275
0.074
19
0
180
90
Yes
IV.9 A5
LO
Wall
Wood
165
0.074
19
0
270
90
Yes
IV.9 A5
L2
RoofRad
Wood
1541
0.032
30
0
n/a
0
Yes
IV.1 A7
SLEEPING
4
Wall
Wood
139
0.074
19
0
0
90
Yes
IV.9 A5
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3
-------------------------------------------------------------------------------
?roject Title.......... Pasa Tiempo Plan 2 Date..04/04/07 10:02:56
------------------------------------------ ------ - ------------
MICROPAS7 v7.20 File-PSTMP02R Wth-CTZ15SO5 Program -FORM CF-lR
User#-MP0864 User-D & R Cal.cs Run-Pasa Tiempo Plan 2
OPAQUE SURFACES
---------------
U Sheath- Solar -Appendix
Frame Area fact- Cavity ing Act Gains IV Location/
Surface Type (sf) or R-val R-val Azm Tilt Reference Comments
------------ ----- ---- ----- ----- ----- --- ---- --------------------------
7 Wall Wood 310 0..074 19 0 90 90 Yes IV.9 A5
9 Wall Wood 131 0.074 19 0 180 90 Yes IV.9 A5
Ll Wall Wood 653 0.074 19 0 270 90 Yes IV.9 A5
L3 RoofRad Wood 1310 0.032 30 0 n/a 0 Yes IV.1 A7
Surface
LIVING
14 SlabEdge
SLEEPING
15 S1abEdge
PERIMETER LOSSES
Appendix
Length F2 Insul. Solar IV Location/
(ft) Factor R-val Gains Reference Comments
150 0.730 R-0 No IV.26 Al .
146 0.730 R-0 No IV.26 Al.
)rientation
.jIVING
1 Door Front (N)
3 Wind Left (E)
4 Wind Left (E)
6 Door Back- (S)
7 Wind Back (S)
9 Wind Right (W)
-'_0 Wind Right (W)
_3LEEPING
2 Wind Front (N)
5 Door Left ('E)
8 Door Back (S)
.1 Wind Right (W)
Wind Right- (W)
FENESTRATION SURFACES
-------------------
Exterior
Area U- Act Shade
(sf) factor SHGC Azm Tilt Type Location/Comments
40.0
0.400
0.350
0
90
8.0
0.400
0.350
90
90
30.0
0.400
0.350
90
90
96.0.0.400
0.350
180
90
30.0
0.400.
0.350
180
90
25.0
0.400
0.350
270
90
10.0
0.400
0.350
270
90
36.0
0.400
0.350
0
90
.40.0
0.400
0.350
90
90
64.0
0.400
0.350
180
>90
75.0
0.400
0.350
270
90
7.5
0.400
0.350
270
90
Standard FRONT/Vinyl/Wd Dr LoE
Standard LEFT/V.inyl/Wd Op LoE
Standard LEFT1/Vinyl/Wd Op LoE
Standard BACK/Vinyl/Wd Dr LoE
Standard BACK1/Viny.1/Wd Op LoE
Standard RIGHT/Vinyl/Wd'Op LoE
Standard RIGHTI/Vinyl/Wd Op LoE
Standard FRONT2/Vinyl/Wd Op LoE
Standard LEFT2/Vinyl/Wd Dr LoE
Standard BACK2/Vinyl/'Wd Dr LoE
Standard RIGHT2/Vinyl/Wd Op LoE
Standard RIGHT21/Vinyl/Wd Op LoE
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4
Project Title.......... Pasa Tiempo Plan 2. Date..04/04/07 10:02:56
MICROPAS7 v7.20 File-PSTMPO2R. Wth-CTZ15S05 Program -FORM CF-lR
User#-MP0864 User-D & R Calcs .Run-Pasa Tiempo Plan 2
------------------------------------------------------------------------- - - - - - -
Surface
LIVING
.1 Door
3 Window
4 Window
6 Door
7 Window
9 Window.
10 Window
SLEEPING
5 Door
8 Door
11 Window
12 Window
OVERHANGS
---Window--- =-------- --Overhang------=-----
Area Left Right
(sf) Width Height Depth Height Extension Extension
----- ----- -- --- ----- - ----------------------
40.0
n/a
8.0
1.5
2.0
n/a
n/a
8.0
n/a
2.0
1.5
2.0
n/a
n/a
30.0
n/a
5.0
1.5
2.0
n/a
n/a
96.0
n/a
8.0
12.0
1.0
n/a_
n/a
30.0
n/a
5.0
1.5
2.0
n/a
n/a
25.0
n/a
5.0
1.5
2.0
n/a
n/a
10.0
n./a
4.0
1.5
2'.0
n/a
n/a
40.0
n/a
8.0
1.5
2:0
n/a
n/a
64.0
n/a
8.0
1.5
2.0
n/a
n/a
75-0
n/a
5.0
1.5
2.0
n/a
n/a
7.5
n/a
.3.0
1.5
2.0
n/a
n/a
SLAB SURFACES
Area
Slab Type (.sf )
LIVING
Standard Slab. 1541
SLEEPING
Standard Slab 11310
HVAC SYSTEMS
------------
Verified
Number
Verified
Verified
Verified
Verified.Maximum
System
of
Minimum
Refrig Charge
Adequate
Fan Watt
Cooling
Type
Systems
Efficiency ,
EER
or TXV
Airflow
Draw
Capacity
,IVING
Furnace.
1
0..780 AFUE
n/a
n/a
n/a
n/a
n/a .
ACSplit
1
13.00 SEER
No
Yes
No
No
No
_:LEEPING
Furnace
1
0.780 AFUE
n/a
n/a
n/a
n/a
n/a
ACSplit
1
13.00 SEER
No
Yes
No
No
No
:'ERTIFICATE OF COMPLIANCE: RESIDENTIAL.COMPUTER METHOD CF-1R Page 5
)roject Title.......... Pasa Tiempo Plan-2 Date.:04/04/07 10:02:56
-------------------------------------------------------------------------------
MICROPAS7-v7.20 File-PSTMP02_R Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run'-Pasa*Tiempo Plan 2
-------------------------------------------------------------------------------
HVAC SIZING
---- - - - - -
-
Verified
Total
Sensible
Design
Maximum
Heating
Cooling,
Cooling
Cooling
System
Load
Load
Capacity
Capacity
Type
(Btu/hr)
(Btu'/hr)
(Btu/hr)
(Btu/hr)
LIVING
Furnace
28370
n/a
n/a
n/a
ACSplit
n/a
20225
25100.
n/a
SLEEPING'
Furnace
25077
n/a
n/a
n/a
ACSplit
n/a
19427
24109
n/a
Total
53446
39652
49208.
n/a
Orientation of
Maximum.....
Front Facing
0 deg (N)
Sizing
Location
.............
PALM DESERT
Winter
Outside
Design......
26 F
Winter
Inside Design.......
70 F
Summer
Outside
Design......
111 F
Summer
Inside Design.......
75 F
Summer
Range..........
.....
34 F
DUCT SYSTEMS
------------
Verified Verified
Verified
System
Duct.
Duct'
Duct •� Surface
Buried
Type
Location.
,R-value
Leakage Area
Ducts
LIVING
Furnace
Attic
R-4.2
Yes No
No
ACSplit
Attic
R-4.2
Yes No
No.
SLEEPING
Furnace
Attic
R-4.2
Yes No
No
ACSplit:
Attic
R-4.2
Yes No
No'
WATER HEATING SYSTEMS
Number Tank External
Heater in Energy Size Insulation.
-'ank Type Type Distribution Type. System Factor (gal). R-value
1 Large Gas Recirc/Demand 1 n/a 75 R-n/a
v
CERTIFICATE OF COMPLIANCE.: RESIDENTIAL COMPUTER METHOD CF-1R Page 6
?roject'Title.......... Pasa Tiempo Plan 2 Date..04/04/07 10:02:56
-------------------------------------------
MICROPAS7 v7 20 File-PSTMPO2R Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2.
--------------------------------------------------------------------------------
WATER HEATING SYSTEMS DETAIL
Standby. Internal Tank
Recovery Rated Loss .Insulation Pilot
System.. Efficiency Input Fraction R=value Light
1 Large 0.79 n/a. 0.02 R- n/a n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during.plan'check and field inspection. ***
This building incorporates a HERS verified Refrigerant Charge test
Dr a HERS verified. Thermostatic Expansion Valve (TXV). If a
tooling system is not installed, then HERS verification is not necessary.
Chis building incorporates HERS verified Duct Leakage.
-his is a.multiple orientation building. This printout is for the front
-acing North..
.his building incorporates a Radiant Barrier...
'his building incorporates a non-standard Water Heating System.
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC'approved ' testing 'and/or verification methods and ***
*** must be reported on the CF-4R installation certificate. ***
this building incorporates a HERS verified Refrigerant Charge test
)r a HERS verified Thermostatic Expansion Valve (TXV)..-If a
-=ling'system is not installed, then HERS verification is not necessary.
'his building incorporates HERS verified Duct Leakage. Target leakage is
,alculated and documented on the CF-4R. If the measured CFM is above the
,target, then corrective.,action must be taken to reduce the duct leakage and.
.hen must be retested. Alternatively, the compliance calculations could be
-edone without duct testing. If ducts are.not installed, then HERS
.,erification is not necessary.
1
'ERTIFICATE OF COMPLIANCE:.RESIDENTIAL COMPUTER METHOD. CF-1R Page 7
--------------
-------------------------------------------------------------------------------
?roject Title.......... Pasa Tiempo Plan 2. Date..04/04/07 10:02:56
-------------------------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP02R Wth-CTZ15S05 Program -FORM CF-1R
User#7MP0864 User-D & R Calcs Run-Pasa Tiempo.Plan.2
-------------------------------------------------------------------------------
REMARKS
,Ierify HVAC sizing & equipment w/ Mechanical engineer/contractor.
COMPLIANCE STATEMENT
--------------------
This certificate of compliance lists the building features and performance
specifications needed to comply with`Title-24, Parts 1 and 6 of the
California Code. of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design. responsibility. ,
DESIGNER or OWNER DOCUMENTATION AUTHOR
Name.... Bill Currier
Company. Colbourn Currier Noll
Address.. i0675 Treena Street #101
San Diego, CA.92031
Phone... (858) 695-1914
License.
Signed...
(date)
ENFORCEMENT AGENCY
Name....
Title.
Agency..
Phone..
Signed:.
(date)
Name.... Diane P. Mendoza
Company. D & R Calcs.
Address. 14107 Ipava Drive
Poway, CA 92064.
Phone.... 858-486-9506
Signed.. -
/)!�(da
AANDATORY MEASURES CHECKLIST: RESIDENTIAL' MF-1R Page 1
?roject Title.......... Pasa Tiempo Plan 2 Date..04/04/07 10:02:56
Project Address........ 5th & Madison ******* ---------------------
La Quinta *v7.20*
Documentation Author... Diane P. Mendoza ******* Building Permit #
D & R Calcs
14107 Ipava Drive Plan Check / Date
Poway, CA 92064
858-486-9506 Field Check/ Date
_'limate Zone........... 15 ---------------------
-ompliance Method...... MICROPAS7 v7.20 for 2,005 Standards by Enercomp, Inc.-
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.20. File-PSTMPO2R Wth-CTZ15S05 Program -FORM MF-1R
{ User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2
-------------------------------------------------------------------------------
Jote: Lowrise residential buildings subject to the Standards must contain.these
measures regardless of the compliance approach used. More stringent compliance
:equirements from.the Certificate of Compliance supersede the items marked with
in asterisk (*). When this checklist is incorporated into the permit documents,
-he features noted shall be.considered by all parties as minimum component
performance specifications for the mandatory measures whether they are shown
L�lsewhere in the documents or on this checklist only.
_3UILDING ENVELOPE MEASURES
n/a
,150(a): Minimum R-19 insulation in wood framed ceiling or
equivalent U-factor in metal frame ceiling.
150(b): Loose fill insulation manufacturer's labeled R-Value
,150(c): Minimum R713 wall insulation in wood framed walls or
equivalent U-factor in metal frame walls (does not apply
to exterior mass walls)
'150(d): Minimum R-13 raised floor insulation in framed floors
or.equivalent U-factor
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door covering the entire
opening of the firebox
b. Outside air intake with damper and control, flue
damper and control
2. No continuous burning gas pilot lights allowed
150(f): Air retarding wrap installed to comply with Sec. 151
meets requirements specified in ACM Residential Manual
'150(g): Vapor barriers mandatory in Climate Zones 14,16 only
150(1): Slab edge insulation - water absorption rate for the
insulation material without facings no greater than 0.3%,
water vapor permeance rate no greater than 2.0 perm/inch
118: Insulation specified or installed meets insulation quality
standards. Indicate type and include CF-6R form
116-17: Fenestration Products, Exterior Doors and Infiltration/
Exfiltration Controls
1. Doors and.windows between conditioned and unconditioned
spaces designed to limit air leakage
2. Fenestration -products -(except field -fabricated) have
De-. En-
sign- force-
'er ment
4ANDATORY MEASURES CHECKLIST: RESIDENTIAL
MF-1R Page 2
?roject Title.......... Pasa Tiempo Plan 2 Date..04/04/07 10:02:56
MICROPAS7 v7.20 File-PSTMPO2R Wth-CT215S05 Program -FORM MF-1R
User#-MP0864' User-D & R Calcs Run-Pasa Tiempo Plan 2
label with certified U-factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certif.ication
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
110-113: HVAC.equipment, water heaters, showerheads and
faucets certified by the Energy Commission
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA
De- En-
sign- force
n/a er ment
150(i) Setback thermostat on all applicable heating and/or
cooling systems
150(j): Water system pipe and tank insulation and cooling
systems line insulation
1. Storage gas water heaters rated with an Energy Factor
less than 0..58 must be externally wrapped with insulation
having an installed thermal resistance of R12 or greater
2. Back-up tanks for solar system, unfired storage tanks, or
other indirect hot water tanks have R-12 external
insulation or R-16 internal and indicated on the
exterior of the tank showing the.R-value
3. The following piping is insulated according to Table 150-A/B
or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water.pipes closest to
water heater tank, no systems, and
entire length of recirculating sections of hot water
pipes shall be insulated to Table 150B
2. Cooling system piping (suction., chilled water, or
brine lines), piping insulated between heating source.
and indirect hot water tank shall be insulated to
Table 150-B and Equation 150-A
4. Steam hydronic heating systems or hot water systems >15 psi,*
meet requirements of Table 123-A
5. Insulation must be protected from damage, including that due
to sunlight, moisture, equipment maintenance and wind
6. Insulation for chilled water piping and refrigerant suction
piping includes a vapor retardant or is enclosed entirely
in conditioned space
7. Solar water -heating systems/collectors are certified by the..
Solar Rating and Certification Corporation —�-
150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to
meet the requirements of the CMC Sections 601, 602, 603,
604, 605 and Standard 6-5; supply -air and return -air ducts
and plenums are insulated to a minimum installed level of
R-4.2 or enclosed entirely in conditioned.space. Openings
shall be sealed with mastic, tape; or other duct -closure
system that meets the applicable requirements of UL 181,
4ANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 3
----------------------------------------=---------------=----------------------
-------------------------------------------------------------------------------
?roject Title............ Pasts Tiempo Plan 2 Date..04/04/07 10:02:56
-------------------------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP02R Wth-CTZ15S05 .Program -FORM MF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2
UL 181A, or UL 181B or aerosol sealant that meets the
requirements of UL 723. If mastic or tape is used to seal
openings greater than 1/4 inch,. the combination of mastic
and either mesh or tape shall be used
2. Building cavities, support platforms for air handlers, and
plenums defined or constructed with materials other than
sealed sheet metal, duct board or flexible duct shall not
be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in
cavities and support platforms shall not be compressed to
reductions in the cross -sectional area of the ducts _
3. Joints and seams -of duct systems and their components
shall not be sealed with cloth backed rubber adhesive
duct tapes unless such tape is used in combination with
mastic and draw bands _
4. Exhaust fan systems have back draft or automatic dampers
5. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
operated dampers
6. Protection of Insulation. Insulation shall be protected
,from damage due to sunlight, moisture, equipment mainten-
ance and wind. Cellular foam insulation shall be protected
as above or painted with a coating that is water retardant
and provides shielding from solar radiation that can cause
degradation of the material
7. Flexible ducts cannot have porous inner cores
114: Pool and Spa Heating Systems and Equipment
1..A thermal efficiency that complies with the'Appliance
Efficiency Regulations, on -off switch mounted outside of
the heater, weatherproof operating instructions, no
electric resistance heating and no pilot light
2. System is installed with:
cause
a. At least 36 inches of pipe between filter and heater
for future solar.heating
b. Cover for outdoor pools or outdoor spas.
3..Pool system has directional inlets and a circulation
pump time switch
115: Gas -fired central furnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
pilot.light (Exception: Non -electrical cooking appliances
with pilot < 150 Btu/hr)
118(i): Cool Roof material meets specified criteria .
..ESIDENTIAL LIGHTING MEASURES De.- En-
sign- force
n/a er ment
150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID:
contain only high efficacy lamps as outlined in Table
15.0-C,, and do not contain a medium screw -base socket
(E24/E26). Ballast for lamps 13 watts or greater are electronic
and have an output frequency no less than 20 kHz
RANDATORY MEASURES
CHECKLIST:
RESIDENTIAL
MF-1R
Page 4
?roject Title.......... Pasa
Tiempo Plan 2
Date..04/04/07
10:02:56
MICROPAS7 v7'.20 File-PSTMPO2R Wth-CTZ15S05 Program -FORM MF-1R
User#-MP0864 User-D &.R Calcs Run-Pasa Tiempo Plan 2
150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain
only high efficacy lamps as outlined in Table 150-C,
luminaire has factory installed HID ballast
150(k)2: Permanently installed luminaires in kitchens shall
be high efficacy luminaires. Up to 50 percent of the wattage,
as determined in Sec. 130(c), of permanently installed luminaires
in kitchens may be in luminaires that are not high efficacy
luminaires, provided that these luminaires are controlled
by switches separate from those controlling the high
.efficacy luminaires
.50(k)3: Permanently installed luminaires in bathrooms,
garages,.laundry rooms, utility rooms shall be high
efficacy luminaires OR are controlled by an occupant
sensor(s) certified to comply with Section 119(d) that
does not turn on automatically or have an always on option
.50(k)4: Permanently installed luminaires located other than
in kitchens, bathrooms, garages, laundry rooms, and utility
rooms'shall be high efficacy luminaires (except closets
less than 70 ft2), OR are controlled by a dimmer switch
OR are controlled by an occupant sensor(s) that complies
with Section 119(d) that does not turn on automatically
or have an always on -option
_50(k)5: Luminaires that are recessed into insulated ceilings
are approved for zero clearance insulation cover (IC) and
are certified air tight to ASTM E283 and labeled as air.
tight (AT).to less than 2.0 CFM at 75 Pascals
.50(k)6: Luminaires providing outdoor lighting and permanently
mounted to a residential building or to other buildings on
the same lot shall be high efficacy luminaires (not in-
cluding lighting around swimming pools/water features or
other Article 680 locations) OR are controlled by occupant
sensors with integral photo control certified to comply
with Section 119(d)
'.50(k)7: Lighting for parking.lots for 8 or more vehicles shall
have lighting that complies with Sec. 130, 132, and 147.
Lighting for parking garages.for 8 or more vehicles shall
have lighting that complies with Sec. 130, 131, and. 146 —�
_50(k)8: Permanently installed lighting in the enclosed, non-.
dwelling spaces of low-rise residential buildings with four
or more dwelling units -shall be high efficacy luminaires OR
are controlled by an occupant sensor(s) certified to
comply with Section 119(d)
AVAC SIZING' HVAC Page 1
?roject Title.......... Pasa Tiempo Plan 2 Date..04/04/07 10:02:56
Project Address........ 5th & Madison ******* ---------------------
La Quinta *v7.20*
7ocumentation Author...- Diane P. Mendoza ******* Building Permit #
D & R Calcs
14107. Ipava Drive Plan Check / Date
Poway, 'CA 92064
858-486-9506 Field Check/ Date
_'limate Zone........... 15 ---------------------
ompliance Method...... MICROPAS7 v7.20 for 2005 Standards by Enercomp, Inc.
------------=-------------------------------=-------------=--------------------
MICROPAS7 v7.20 File-PSTMPO2R Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2
c
--------------------------------------------------------------------=----------
GENERAL INFORMATION
Floor Area ......... :.......
Volume ....................
Front Orientation..........
Sizing Location............
Latitude .................:.
Winter Outside Design......
Winter Inside Design.......
Summer Outside Design......
Summer Inside Design.......
Summer Range., .............
Interior Shading Used......
Exterior Shading Used......
Overhang Shading Used......
Latent Load Fraction.......
Description
2851 sf
29839 cf
Front Facing 0 deg -(N)
PALM DESERT
33.7 degrees
26 F
70 F
111 F
75 F
34 F
Yes
Yes
Yes
0.24
HEATING AND COOLING LOAD SUMMARY
--------------------------------
Opaque Conduction and Solar......
Glazing Conduction and Solar.....
Infiltration ................ ....
Internal Gain............ ......
Ducts. ...........................
Sensible Load:..... ...........
Latent Load.* ....................
Heating Cooling
(Btu/hr) (Btu/hr)
26260
11122
8122
13223
10735
6207
n/-a
2290
8329
6811.
53446 39652
n/a 9556
Minimum Total Load 53446 49208
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outside air, outdoor design temperatures, .coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It is the HVAC designer's responsibility 'to consider all
factors when selecting the HVAC equipment.
-TVAC SIZING HVAC Page 2
--------------------------------
Iroject Title........... Pasa Tiempo Plan 2. Date..04/04/07 10:02;56
-------------------------------------------------------
MICROPAS7 v7.20 File-PSTMPO2R Wth-CTZ15S05 'Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2
--------------------
------------------------------------------------------------
HEATING AND COOLING LOAD SUMMARY BY ZONE
ZONE 'LIVING '
Floor Area... ...............
1541 sf
Volume ...........................
16739 cf
Heating
Cooling
Description
(Btu/hr)
-----------
(Btu/hr)
----------,-
---------------------------------
Opaque Conduction and Solar.......
13940
5867
Glazing Conduction and•Solar......
4206
6293
Infiltration . ............ .....
5802
3355
Internal Gain........ ..........
n/a
1237
Ducts ............................
4421
3474
Sensible Load .....................
28370
20225
Latent Load........ ........ ..
n/a
4874
Minimum Zone Load
28370
25100
ZONE 'SLEEPING'
Floor Area. ... ................
1310 sf
Volume ...........................
13100 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
12320
5255
Glazing Conduction and Solar......
3916
6929
Infiltration .....................
4933
2852
Internal Gain ....................
n/a
.1053
Ducts ............................
3908
3337
Sensible.Load.....................
25077
19427
Latent Load .......................
n/a
4682
Minimum Zone Load
----- - - - - -- .-
25077
---- - - - - - -
.24109
-iVAC SIZING { HVAC Page 3
-------------------------------------------------------------------------------
?roject Title..........., Pasa.Tiempo Plan 2 Date..04/04/07 10:02:56
-------------------------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP02R Wth-CTZ15S05 Program-HVAC SIZING
' User#-MP0864 User-D & R Calcs, Run-Pasa Tiempo Plan 2
GENERAL INFORMATION
-------------------
Floor Area ................. 2851 sf
Volume.. ................. 29839 cf
Front Orientation.......... Front Facing 90.deg (E)
Sizing Location......... PALM DESERT
Latitude ................... 33.7 degrees
Winter Outside Design...... 26 F
Winter Inside Design....... 70 F
Summer Outside Design...... 111 F
Summer Inside Design....... 75 F
Summer Range ............... 34 F
Interior Shading Used:..... Yes
Exterior Shading Used...... Yes
Overhang Shading'Used...... Yes
Latent Load Fraction ........ 0.24.
HEATING AND COOLING -LOAD SUMMARY
Heating
Cooling
Description
(Btu/.hr).
(Btu/hr)
Opaque Conduction and Solar......
26.260
10445
Glazing Conduction and Solar....:
8122
12722
Infiltration........... .........
10735
6207
Internal Gain..... .............
n/a
2290
Ducts.... ......... ..........
8329
6567
Sensible Load......... .........
-----------
53446
-----------
38230
Latent Load......... ...........
n/a
9213
Minimum Total Load
53446
47443
Note: The loads shown are. only one of the criteria affecting the selection
of HVAC equipment.. Other relevant design.factors such as air flow
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
_1VAC SIZING HVAC Page 4.
?roject Title............ Pasa Tiempo Plan 2 Date..04/04./07 10:02:56
MICROPAS7 v7.20 File-PSTMP02R Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2
HEATING AND COOLING LOAD SUMMARY BY ZONE
ZONE 'LIVING'
Floor Area......... 1541 sf
Volume ............................ 16739 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
13940
5752
Glazing Conduction and Solar.....
4206
6234
Infiltration.. .......
58.02
3355
Internal Gain ....................
n/a
1237
Ducts ............................
4421
3438.
Sensible Load... .............
28370
2.0016
Latent Load. ............... ..
n/a
4824
Minimum Zone Load
28370
24840
ZONE 'SLEEPING'
Floor Area...... .. ........
1310 sf
Volume ............................
13100 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction.and Solar.:....
12320
4692
Glazing Conduction -and Solar.....
3916
6488
Infiltration....... ............
4933
2852
Internal Gain ....................
n/a
1053
Ducts.. ...........................
3908
3128
Sensible Load............." ...
-----------------------
.25077
18214
Latent Load... ......... ....
n/a
43.90
Minimum,Zorie Load
25077
22603
_1VAC SIZING HVAC Page 5
----------------------
Project Title...:...... Pasa Tiempo Plan 2 Date..0.4/04/07 10:02:56
MICROPAS7 v7 20 File-PSTMP02R Wth-CTZ15SO5 Program-HVAC SIZING
' User#-MP0864 User-D.& R Calcs Run-Pasa Tiempo Plan 2
--------------------------------------------------------------------------------
GENERAL INFORMATION
Floor Area ................. 2851 sf
Volume ......... .............:29839 cf
Front Orientation.......... Front Facing
Sizing Location............ PALM DESERT
Latitude. .... 33.7 degrees
Winter Outside Design...... 26 F
Winter Inside Design........ 70 F
Summer Outside Design...... 111 F
Summer Inside Design........ 75 F'
Summer Range ............... 34 F
Interior Shading Used ....... Yes
Exterior Shading -Used ....... Yes
Overhang.Shading Used....... Yes
Latent Load Fraction....... 0.24
HEATING AND COOLING LOAD SUMMARY
--------------------------------
Heating
Description (Btu/hr)
Opaque Conduction and Solar...... .26260
Glazing Conduction and Solar..... 8122
Infiltration ..................... 10735
Internal Gain... ...... n/a
Ducts.. 8329
Sensible Load............ ...... 53446
Latent Load ...................... n/a
Minimum -Total Load 53446
180 deg (S)
Cooling
(Btu/hr)
11110
13222
6207
2290
6808
39637
9553
49.190
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment.' Other relevant design factors such. as air flow
requirements, outside air, outdoor design temperature.s, coil sizing,
availability of equipment, oversizing safety margin, etc., must also 'be
considered. It is the HVAC designer's responsibility to consider- all
factors when selecting the HVAC equipment.
[VAC SIZING HVAC Page 6
'roject Title.......... Pasa Tiempo Plan 2 Date...04/04/07,10:02:56
---------------------------------------------------------
MICROPAS7 v7 20 File-PSTMPO2R Wth,CTZ15S05 Program-HVAC SIZING.
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan72
-------------------------------------------------------------------------------
HEATING AND COOLING LOAD SUMMARY BY ZONE
----------------------------------------
ZONE 'LIVING'
Floor Area ........................
1541 sf
Volume ...........................
16739 cf
'Heating:
Cooling
Description
(Btu/hr).
(Btu/hr)
Opaque Conduction and Solar......
13.940
5853
Glazing Conduction and Solar.....
4206
6293
Infiltration ........................
5802
3355
Internal Gain... ...............
n/a
1237
Ducts....... .........:.........
4421
3471
Sensible Load.. .... .............
28370
20208
Latent Load .......................
n/a
4870
Minimum Zone Load
28370
25078
ZONE 'SLEEPING'
Floor Area... .................... 1310 sf
Volume.. 13100 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
12320
5257
Glazing,Conduction and Solar.....
3916
6929
Infiltration.......... .............
49.33
2852
Internal Gain.................
n/a
1053
Ducts ..............................
3908
3337
Sensible Load ....................
-----------
25077
-----------
19429
Latent Load .........................
n/a
4682
Minimum Zone Load
----------------------
25077
24112
_1VAC SIZING HVAC Page 7
-------------------------------------
'roject Title.......... Pasa Tiempo Plan 2 Date..04/04/07 10:02:56
MICROPAS7 v7 20 File-PSTMP02R Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2
--------------------------------------------------------------------------------
GENERAL INFORMATION
Floor Area .................
2851 sf
Volume ......... ...........
29839 cf
Front Orientation..........
Front Facing
270 deg (W)
Sizing Location. ..........
PALM DESERT
p
Latitude ... ...............
33.7 degrees
Winter Outside Des .ign......
26 F
Winter Inside Design...:...
70 F
Summer Outside Design......
111-F
Summer Inside Design.......
75 F
Summer Range ...............
34 F
Interior Shading Used......
Yes.
Exterior Shading Used......
Yes
Overhang Shading Used......
Yes.
Latent Load Fraction.......
0.24
HEATING AND COOLING
LOAD SUMMARY
Heating
Cooling
Description
---------------------------------
(Btu/hr)
----------------------
(Btu/hr)
Opaque Conduction and Solar.......
26260
10503
Glazing Conduction and Solar.....
8122
12.722
Infiltration .....................
10735
6207
Internal Gain.........
n/a
2290
Ducts ............................
8329
65.79
Sensible Load........
53446
38301
Latent -Load .............
n/a
9230
Minimum Total Load
53446
47531
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin,.etc., must also be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
3VAC SIZING HVAC Page 8
---------------------------------------------------==--------------------------
Project Title ........... Pasa Tiempo Plan 2 Date..04/04/07 10:02:56
MICROPAS7 V7.20 File-PSTMPO2R Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864. User-D & R Calcs Run-Pasa Tiempo Plan 2
HEATING AND COOLING LOAD SUMMARY BY ZONE
----------------------------------------
ZONE 'LIVING'
.Floor Area .............. ....
1541 sf
Volume..... ....................
16739 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque.Conduction and Solar......
13940
5720
Glazing Conduction and Solar......
4206
6234
Infiltration.. ............ ....
5802
3355
Internal Gain........ ........
n/a
1237
Ducts............ .... .. .....
4421
3431
Sensible Load....... ...........
28.370
19977
Latent Load ......................
n/a
4815
Minimum Zone Load
28370
24792
ZONE 'SLEEPING'
Floor Area........ ................
1310 sf
Volume... ......... ...........
13100 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
12320
4783
Glazing Conduction and Solar..'....
3916
.6488
Infiltration...... ..... .......
4933
2852
Internal -Gain.......'.:......
n/a
1053
Ducts .............................
3908
3147
Sensible Load..................
25077
18323
Latent Load ......................
n/a
4416
Minimum Zone Load
25077
22739
12
PASA-TIEMPO
PLAN 2'w/ CASITA
LA QUINTA, CA
CLIMATE ZONE 15
Title 24 Energy Calculations D & R Calcs
Micropas v7.20 Performance Method (858) 486-9506
April 4:, 2007 "
TITLE,24 COMPLIANCE REQUIREMENTS SUMMARY
Pasa Tiempo Plan 2 w/ Casita
Ceiling Insulation = R-30 min. PROVIDE RADIANT BARRIER ROOF SHT'G
(NOTE ON PLANS)
Wall Insulation = R-19 min.
Floor Insulation = N/A
Thermal Mass Areas = See Floor plan
Glazing All .windows & doors to be dual glazed. Ali glass is.Low E.
Glazing shall be installed with -a NFRC certifying label.
attached.showing Uvalue.
Solar Heat Gain Co -efficient = 0.35 dual windows, , doors
Uvalue = 0.40 vinyl/wd windows & doors
Owner to purchase windows & doors w/ specified Uvalues & SHGC's or better.
Hot Water Heater = (1) 75 gal A.O.Smith #BTC-251 *** or eq. Standby
loss is 2.0 min. Provide a recirc pump..
Infiltration Standard
AFUE - 0. 78 min.
SEER - 13. 0 min. WITH TXV
Duct Insulation = R-4.2. min. ' PROVIDE DUCT TESTING BY HERS RATER
Heater sizing
Zone 1 "LIVING" Sensible heat load*- 28,292 Btu
(verify HVAC equip. wl Mechanical)
Zone 2 "SLEEPING" 'Sensible heat load 31,.001 Btu
'(verify HVAC equip.. w/ Mechanical)
A/C Sizing
Zone 1 "LIVING" Sensible cool'g
load
= 2.0,045
Btu
Latent.cool'g
load
= 4;831
Btu
Zone 2 "SLEEPING" Sensible cool'g
load
= 23,212
Btu
i, Latent.cool'g
load
= 5,594
Btu
Verify HVAC sizing & equipment with a Mechanical Engineer/Contractor..
Owner may install any Make &.Model HVAC equipment that is equal or greater.
than the minimum efficiencies listed above. All equipment is listed "or.eq
,CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1
-------------------------=-------------------------=---------------------------
?ro.ject Title.......... Pasa.Tiempo Plan (2/Casita Date..04/04/07 10:09:43
-3roject Address........ 5th & Madison *******---------------------
La Quinta *v7.20*
Documentation Author... Diane P. Mendoza ******* Building Permit #
D & R Calcs
14107 Ipava Drive Plan Check / Date
Poway, CA 92064
858-486-9506 Field Check/ Date
:limate Zone........... 15 ---------------------
_ompliance Method...... MICROPAS7 v7.20 for 2005 Standards -by Enercomp, Inc.
------------------------------- -- - ----
MICROPAS7 v7.20 File-PSTMP2CR Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2/Casita
----------------------------------------------------------=--
=
MICROPAS7
ENERGY USE
SUMMARY
=
_ 'Energy
----------------------------
Use
Standard
Proposed Compliance
=
_ (kTDV/sf-yr)
Design
Design
Margin =
= Space
Heating..........
2.15
2.13
0.02 _
= Space
Cooling...:....
69.04
68.33
0.71 =
= Water
Heating..........
8.25
8.51
-0.26 =
=
North Total
79.44
78.97
0.47 =.
= Space
Heating..........
2.15
2.34
-0.19 =
= Space
Cooling.. ......
69.04
67.39 _
1.65 =
= Water
Heating..........
8.25
.8.51
-6.26 =
=
East Total
79.44
78.24
1.20 =
J
= Space
Heating...... ..
2.15
2.34
-0.19 =
Space
Cooling..........
69.04
66.86
2.18 =
= Water
Heating..... ...
8.25
8.51
-0..26 =
=
South Total
79.44
77.71
1.73 =
= Space
Heating..........
2.15
2.01
0.14 =
- Space
Cooling..........
69.04
67.66
1.38 =
= Water
Heating..........
8.25
.8.51
70.26 =
=
West Total
79.44
78.18
1.26 =
_ ***Building
complies
with Computer
Performance
_
------=----------------------------------------------------------
*** HERS Verification
Required
for Compliance"**,*
_
s
"ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2
?roject Title.......... Pasa Tiempo Plan 2/Casita Date..04/04/07 10:09:43
-------------------------------------------------------------=-----------------
-------------------------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP2CR Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan-2/Casita
-------------------------------------------------------------------------------
GENERAL INFORMATION
HERS Verification.......... Required
Conditioned Floor Area..... 3115 sf.
Building Type .............. Single Family Detached
Construction Type New
Fuel Type ................. NaturalGas.
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type..:....... FullYear
Floor Construction Type....
Number of Building Zones...
Conditioned Volume;....r...
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U-factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Slab On Grade
2
32479 cf
3115 sf
16.6 % of floor area
0..4 Btu/hr-sf-F
0.35
10.4 ft
BUILDING ZONE INFORMATION
Floor
# of
# of
Cond-
Thermo-
Vent
Vent Verified
Area
Volume
Dwell
Peop-
it-
stat
Height
Area Leakage or
;one Type
(sf)
(cf)
Units
le
ioned
Type
(ft)
(sf) Housewrap
-------------
__jIVING
-----
------
-----
-----
-----
--------
-----
-----------------
Residence
1541
16739
0.49
1.5
Yes
Setback
2.0
Standard No
`;LEEPING
Residence
1574
15740
0.51
1.5
Yes
Setback
2.0
Standard No
_�urface
T,IVING
1 Door
2 Wall
3 Wall
5 ,Wall
6 Wall
8 Wall
-0 Wall.
2 RoofRad
-LEEPING
4 Wall
OPAQUE SURFACES
U-
---------------
Sheath-
Solar
Appendix
Frame
Area
fact-
Cavity
ing
Act
Gains
IV Location/
Type
(sf)
or
R-val
R-val
Azm
Tilt
Reference Comments
Wood
28
0.500
0
.0
315
90
Yes
IV.5
A4
Wood
120
0.074
19
0
0
90
Yes
IV.9
A5
Wood
210
0.074
19
0
0
'90
No
IV.9
A5
Wood
392
0.074
19
0
90
90
Yes
IV.9
A5
Wood
150
0.074
19
0
90,
90
No
IV.9
A5
Wood
275
0.074
19
0
180
90
Yes
IV.9
A5
Wood
165
0.074
19
0
270
90
Yes
IV.9
A5
Wood
1541
0.032
30.
0
n/a
0
Yes
IV.1
A7
Wood
209
0.074
19
0
0
90
Yes
IV.9
A5
'ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3
------------------------------------------------------------------------------=
?roject Title........... Pasa Tiempo Plan 2/Casita Date..04/04/07 10:09:43
-----------------------------------------=-------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP2CR Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2/Casita
-------------------------------------------------------------------------------
Surface
------------
7 Wall
9 Wall
'.1 Wall
__3 RoofRad
Surface
LIVING
14.S1abEdge
SLEEPING
15 SlabEdge
')rientation
OPAQUE SURFACES
U-
---------------
Sheath-
Solar
Appendix
Frame
Area
fact-
Cavity ing
Act
Gains
IV Location/
Type
(sf)
or
R-val R-val
Azm
Tilt
Reference Comments
Wood
'420
0.074
19 0
90
90
Yes
IV.9 A5
Wood
171
0.074
19 0
180
90
Yes
IV.9-A5
Wood
.758
0.074
19 0
270
90
Yes
IV.9 A5
Wood
1574
0.032
30 0
n/a
0
Yes
IV.1 A7
PERIMETER LOSSES
----------------
Appendix
Length F2 Insul Solar IV Location/
(ft)' Factor R-val Gains Reference Comments
150
184
JIVING
1
Door
Front
(N)
3
Wind
Left
(E)
4
Wind
Left
(E)
6
Door
Back
(S)
7
Wind
Back
(S)
9
Wind
Right
(W)
.0
Wind
Right
(W)
jLEEPING
2
Wind
Front
(N)
5
Door
Left
(E)
8
Door
Back
(S)
.1
Wind
Right.
(W)
-.2
Wind
Right
(W)
0.730 R-0 No IV.26 Al
0.730 R-0 No IV.26 Al
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
(sf).factor SHGC Azm Tilt Type
----- ----- ----- --- ------------
Location/Comments
------------------------
40'.0
0.400
0.350
0
90
Standard
FRONT/Vinyl/Wd Dr LoE
8.0
0.400
0.350
90
90
Standard
LEFT/Vinyl/Wd Op LoE
30.0
0.400
0.350
90
90
Standard
LEFT1/Vinyl/Wd Op LoE
96.0
'0.400
0.350.180
90
Standard
BACK/Vinyl/Wd Dr Lo'E
30.0
0.400
0'.350
180
90
Standard
BACK11/Vinyl/Wd Op LoE
25.0
0.400
0.350
27,0
90
Standard
RIGHT/Vinyl/Wd Op LoE
10.0
0.400
0.350
270
90
Standard
RIGHTI/Vinyl/Wd Op LoE
51.0
0.400
0.350
0
90
Standard
FRONT2/Vinyl/Wd Op'LoE
.40.0
0.400-0.350
90
90
Standard
LEFT2/Vinyl/Wd Dr LoE
104.0
0.400
0.350
180
90
Standard'BACK2/Vinyl/Wd
Dr LoE
75.0
0.400
0.350
270
90
Standard
RIGHT2/Vinyl/Wd Op LoE
7.5
0.400
0.350
270
90
Standard
RIGHT21/Vinyl/Wd Op LoE
1
:ERTIFICATE OF
COMPLIANCE: RESIDENTIAL COMPUTER.METHOD
CF-1R Page 4
?roject
Title
Pasa
Tiempo Plan
2/Casita
Date..04/04/07 10:.09.:43
----------------------------------------------------------------------
MICROPAS7
v7.20 ..File-PSTMP2CR
Wth-CTZ15S05
Program
-FORM CF-1R.
t
User#-MP0864"
User-D
& R Calcs.
Run-Pasa Tiempo
Plan 2/Casita
OVERHANGS
---Window---
-------------
Overhang
------------
Area.
Left
' Right
Surface
(sf).Width
Height Depth
-Height Extension
Extension
LIVING
1
Door
40.0
n/a
8.0 1.5
2.0.
n/a
n/a
3
Window
8.0
n/a
2.0 1.5
2.0
n'/a
n/a
4
Window"
30.0
n/a
5.0 1.5
2.0
n/a
n/a
6
Door
9.6.0
n/a
8.0 .12..5
1.0
n/a
n/a
7
Window
30.0
n/a
5.0 1.5
2.0
n/a
n/a
9
Window
25.0
n/a
5.0. 1.5
2.0
n/a
n/a.
10
Window
10.0
n/a
4.0 -1.5
2.0
n/a
n/a
SLEEPING
5
D"oor
40.0
n/a
8.0 1.5
"2.0
n/a
n/a
8
Door.
104.0
n/a
8.0 1.5
2.0
n/a
n/a
11
Window
75.0
n/a
5.0 1.5
2.0
n/a
n/a
12
Window
7.5
n/a
3.0 1.5
2.0
n/a
n/a
SLAB SURFACES
Area
Slab Type
(sf)
LIVING
Standard
Slab 1541
SLEEPING
Standard Slab 1574
HVAC SYSTEMS
------------
Verified
Number.
Verified
Verified
Verified
Verified
Maximum
System
of
Minimum
Refrig Charge
Adequate
Fan Watt
Cooling
Type
Systems
Efficiency.
EER
or TXV
Airflow
Draw
Capacity
_jIVING
Furnace
1
0.780 AFUE
n/a
n/a.
n/a
n/a
n/a
ACSplit
1
13.00 SEER
No
Yes
No
No
No
.>LEEPING
Furnace
1
0.780 AFUE
n/a
n/a
n/a
n/a'
n/a
ACSplit
1
13.00 SEER
No
Yes
No
No
No'
:ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD
CF-1R Page 5
?roject.Title..........
Pasa Tiempo Plan.2/Casita
Date..04/04/07 10:09:43
1 MICROPAS7 v7 20
-------------------------------------------------
File-PSTMP2CR Wth-CTZ15S05 Program
-FORM CF-1R.
User#-MP0864
-----------------------------------
User-D & R
Calcs Run-Pasa Tiempo
7--------------------------------------------
Plan 2/Casita,
HVAC SIZING,
Verified
Total
Sensible
Design.
Maximum
Heating
Cooling
Cooling
Cooling
System
Load
Load
Capacity
Capacity
Type
(Btu/hr)
(Btu/hr)
(Btu/hr)
(Btu/hr)'
LIVING
Furnace
28292
n/a
n/a
n/a
ACSplit
n/a
20045
24876
n/a
SLEEPING
Furnace.
31001
n/a
n/a
n/a
ACSplit
n/a
23101
28668
n/a
Total
59292
43146
53545.
n/a
Orientation of Maximum....
Sizing Location... ........
Winter Outside Design......
Winter Inside Design.......
Summer Outside Design......
Summer Inside Design.......
Summer Range ...............
Front Facing O,deg (N)
PALM . DESERT
26 F ,
70 F
111 F
75 F
34 F
DUCT SYSTEMS
Verified
Verified
Verified -
System
Duct
Duct
Duct
Surface
Buried
Type
Location
R-value
Leakage
Area
Ducts
LIVING
Furnace.
Attic
R-4.2
Yes-
No
No.
ACSplit
Attic
R-4.2
Yes
No
No
SLEEPING
Furnace
Attic
R-4.2
Yes
No
No
ACSplit
Attic,
R-4.2
Yes
No
No
Heater
'ank Type Type
1 Large Gas
WATER HEATING SYSTEMS
Number
in Energy
Distribution Type System: Factor.
Recirc/Demand 1 n/a
Tank '
External
Size.
Insulation
(gal)
R-value
75
R-n/a
'ERTIFICATE.OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6
-------------=-----------------------------------------------------------------
-------------------------------------------------------------------------------
'roject Title.......... Pasa Tiempo Plan 2/Casita Date..04/04/07 10:09:43
---------=----------=-------------------------------------------------=--------
MICROPAS7 v7.20 File-PSTMP2CR Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2/Casita
-------------------------------------------------------------------------------
WATER.HEATING SYSTEMS DETAIL
Standby Internal Tank .
Recovery Rated Loss Insulation Pilot
System Efficiency Input Fraction R-value Light
--------------------------------------------------------------------
1 Large 0.79 n/a 0.02 R- n/a. n/a
SPECIAL FEATURES AND%MODELING ASSUMPTIONS
-----------------------------------------
*** Items in thissection should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
—his building incorporates a HERS verified Refrigerant Charge test
jr a HERS verified Thermostatic Expansion Valve (TXV). If a
:ooling.system is not installed, then HERS verification is not necessary.
:his building incorporates HERS verified Duct Leakage.
—his is a multiple orientation building. This printout is for the front
pacing North.
—his-building incorporates a Radiant Barrier.
'his building incorporates a non-standard Water Heating System.
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-4R installation certificate. ***
.'his building incorporates a HERS verified Refrigerant Charge test
,r a HERS verified Thermostatic Expansion Valve (TXV). If a
.00ling system is not installed, then HERS verification is not necessary.
'his building incorporates HERS verified Duct Leakage. Target leakage is
!alculated and documented on the CF-4R. If the measured CFM is above the
Larget, then corrective.action must be taken to reduce the duct leakage and
hen must be retested. Alternatively, the compliance calculations could be
-edone without duct testing. If ducts are not installed, then HERS
verification is no_t.necessary.
'_ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 7
?roject Title.......... Pasa Tiempo Plan 2/Casita Date..04/04/07 10:09:43
--------------
. .MICROPAS7 v7.20 File-PSTMP2CR Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2/Casita I.
-------------------------------------------------------------------------------
REMARKS
�Terify HVAC sizing & equipment W/ Mechanical engineer/contractor.
COMPLIANCE STATEMENT
This certificate of compliance lists the, building,features and performance
specifications needed to comply with Title-24,'Parts 1 and 6 of the
California Code of Regulations, and the administrative' regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility.
DESIGNER or OWNER DOCUMENTATION AUTHOR
Name..... Bill Currier
Company..Colbourn Currier Noll
Address. 10675 Treena Street#101
San Diego, CA 92031
Phone:.. (858) 695-1914
License.
Signed..
(date)
Name....
Title...
Agency..
Phone...
Signed.
Name.... Diane P. Mendoza
Company. D & R Calcs
Address. 14107 Ipava Drive
Poway, CA 92064
Phone... 858-486-9506
Signed..
ENFORCEMENT AGENCY
(date)
t
--IANDATORY MEASURES CHECKLIST: RESIDENTIAL
MF-1R
Page 1
'roject Title..........
Pasa Tiempo Plan 2/Casita
----------------
Date..04/04/07 10:09:43
-'roject Address........
5th & Madison
******* ---------------------
I
La Quinta
*v7:20*
)ocumentation Author...
Diane P. Mendoza
*******
Building Permit #
D & R Calcs
14107 Ipava Drive
Plan Check /
Date
Poway, CA 92064
858-486-9506
Field Check/
Date
'limate Zone..... ......
15
---------------------
.ompliance Method......
MICROPAS7 v7.20 for 2005
Standards by Enercomp,
Inc.
MICROPAS7 v7.20
File-PSTMP2CR Wth-CTZ15S05
Program -FORM MF-1R
User#-MP0864
-----------------------------------------------------------------------------=
User-D & R Calcs Run-Pasa
Tiempo Plan 2/Casit-a
Tote: Lowrise residential buildings subject to the.Standards must contain these
-ieasures regardless of the compliance approach used. More stringent compliance
--equirements from the Certificate of Compliance supersede the items marked with
in asterisk (*). When this checklist is incorporated into the permit documents,
`.he' features noted shall be considered by all parties as minimum component
,erformance specifications for .the mandatory measures whether they are shown
!lsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
n/a
150(a).: Minimum R-19 insulation in wood framed ceiling or
equivalent U-factor .in metal frame ceiling
150(b): Loose fill insulation manufacturer's labeled R-Value �C
150(c): Minimum-R-13 wall insulation in wood framed walls or
equivalent U-factor in metal frame walls (does not apply
to exterior mass walls)
150(d): Minimum R-13 raised floor insulation in framed floors
or equivalent U-factor
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door covering the entire
opening of the firebox
b. Outside air intake with damper and control, flue
damper and control
2. No continuous burning gas pilot lights allowed
150(f): Air retarding wrap installed to comply with Sec. 151
meets requirements specified in ACM Residential Manual /
150(g): Vapor barriers mandatory in Climate Zones 14,16 only
150.(1): Slab edge insulation - water absorption rate for the
insulation material without facings no greater than 0.30,
water vapor permeance rate.no greater than 2.0 perm/inch
118: Insulation specified or installed meets insulation quality
standards. Indicate type and include CF-6R-form
116-17: Fenestration Products, Exterior Doors and Infiltration/
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage
2..Fenestration products (except field -fabricated) have
De- .En-
sign- force-
er ment
[ANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R
Page 2
_'roject Title.......... Pasa Tiempo Plan 2/Casita Date..04/04/07 10:09:43
------------- -
-----
MICROPAS7 v7.20 File-PSTMP2CR Wth-CTZ15S05 Program-FORM.MF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2/Casita
--------------------------------------------------------------------------------
label with certified U-factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed
PACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De-
En-
sign-
force
n/a er
ment
110-113: HVAC equipment, water heaters, showerheads and.
faucets certified by the Energy Commission
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA
150(i): Setback thermostat on all applicable heating and/or
cooling systems
150(j): Water system pipe and tank insulation and cooling
systems line insulation
1. Storage gas water heaters rated with an -Energy Factor
less than 0.58 must be externally wrapped with insulation
having an installed thermal resistance of.R12 or greater
2. Back-up tanks for solar system, unfired.storage tanks, or
other indirect hot water tanks have R-12 external
insulation or R-16 internal and indicated on the
exterior of the tank showing the R=value
3. The following piping is insulated according to Table 150-A/B
or Equation 150-A Insulation Thickness:
1. First'5 feet of hot and cold water pipes closest to
water heater tank, non -recirculating systems, and
entire length of recirculating sections of hot water
pipes shall be insulated to Table 150B �.
2. Cooling system piping (suction, chilled water, or
brine lines), piping insulated between heating source
and indirect hot water tank shall be insulated to /
Table 150-B and Equation 150-A
4. Steam hydronic heating systems or hot water systems >15 psi,
meet requirements.of Table 123-A
5. Insulation must be protected from damage, including that due
to sunlight, moisture, equipment maintenance and wind
6. Insulation for chilled water piping and refrigerant suction
piping includes a vapor retardant or is enclosed entirely
in conditioned space
7. Solar water -heating systems/collectors are certified by the
Solar Rating and Certification Corporation
150 (m) : Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to
meet the requirements of .the CMC Sections 601, 602, 603,
604, 605 and Standard 6-5; supply -air and return -air ducts
and plenums are insulated to a minimum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings
shall be sealed with mastic, tape, or other duct -closure
system that meets the applicable requirements of UL 181,
QANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 3
-------=---------------------------------------------=-------------------------
?roject Title........... Pasa Tiempo Plan,2/Casita Date..04/04/07 10:09:43
-------------------------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP2CR Wth-CTZ15S05 Program -FORM MF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2/Casita
------------ -------------------------------------------------------------------
UL 181A, or UL 181B or aerosol sealant that meets the
requirements of UL 723. If mastic or tape is used to seal
openings greater than 1/4 inch, the combination of mastic
and either mesh or tape shall be used
2: Building cavities, support platforms for air handlers, and
plenums defined or constructed with materials other than
sealed sheet metal, duct board or flexible duct shall not
.be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in
cavities and support platforms shall not be compressed to cause
reductions in the cross -sectional area of the ducts
3. Joints and seams of duct systems and their components
shall not be sealed with cloth backed rubber adhesive
duct tapes unless such tape is used in combination with
mastic and draw bands
4. Exhaust fan systems have back draft or automatic dampers
5. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually.
operated dampers /
6. Protection of Insulation. Insulation shall be protected
from damage due to sunlight, moisture, equipment mainten-
ance and wind. Cellular foam insulation.shall be protected
as above or painted with a coating that is water retardant
and provides shielding from solar radiation that can cause /
degradation of the material
7. Flexible ducts cannot have porous inner cores
114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance
Efficiency Regulations, -on -off switch mounted outside of
the heater, weatherproof operating instructions, no
electric resistance heating and no pilot light
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for future solar heating
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch
115: Gas -fired central furnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
pilot light (Exception: Non -electrical cooking appliances
with pilot < 150 Btu/hr)
118(i): Cool Roof material meets specified criteria
.ESIDENTIAL LIGHTING MEASURES De- En-
sign -.force
n/a er ment
150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID:
contain only.high efficacy lamps as -outlined in Table
150-C, and do not contain a medium screw base socket
(E24/E26). Ballast for lamps 13 watts or greater are electronic
and have an output frequency no less than 20 kHz
IANDATORY MEASURES CHECKLIST:RESIDENTIAL
MF-1R Page 4
------------------------------
)roject Title........:. Pasa Tiempo Plan 2/Casita Date..04/04/07 10:09:43
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
.MICROPAS7 v7.20 File-PSTMP2CR Wth-CTZ15S05 Program -FORM MF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2/Casita
150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain
only high efficacy lamps as -outlined in Table 150-C,
luminaire has factory installed HID ballast
150(k)2: Permanently installed luminaires in kitchens shall
be high efficacy.luminaires. Up to 50 percent of the wattage,
as determined in Sec. 130(c), of permanently installed luminaires
in kitchens may be in luminaires that are not high efficacy
luminaires, provided that these luminaires are controlled
by switches separate from those controlling the high
efficacy luminaires.
.50(k)3: Permanently installed luminaires in bathrooms,
garages, laundry rooms, utility rooms shall be high
efficacy luminaires OR are controlled by an'occupant
sensor(s) certified to comply with Section 119(d) that
does not turn on automatically or have aft always on option
-1.50(k)4: Permanently installed luminaires located other than
in kitchens, bathrooms, garages, laundry rooms, and utility
rooms shall be high efficacy luminaires (except closets
less than 70 ft2), OR are controlled by a dimmer switch
OR are controlled by an occupant sensor(s) that.complies
with. -Section 119(d) that does not turn on.automatically
or have an always on option
_50(k)5: Luminaires that are recessed into insulated ceilings
are -approved for zero clearance insulation cover (IC) and
are certified air tight to ASTM E283 and labeled as air
tight (AT) to less than 2.0 CFM at 75 Pascals
.50(k)6: Luminaires providing outdoor lighting and permanently
mounted to a residential building or to other buildings on
the same lot shall be high efficacy luminaires (not in-
cluding lighting around swimming pools/water features or
other Article 680 locations.) OR are controlled by occupant
sensors with integral photo control certified to comply
with Section 119(d)
,.50(k)7: Lighting for parking lots for 8 or more vehicles shall
have lighting that complies with Sec. 130, 132, and 147.
Lighting for parking garages for 8 or more vehicles shall
have lighting that complies with Sec. 130, 131, and 146
-50(k)8: Permanently.installed lighting in the enclosed, non -
dwelling spaces of low-rise residential buildings with four
or more dwelling units shall be high efficacy luminaires OR
are controlled by an occupant sensor(s) certified to
comply with Section 119(d)
gVAC SIZING HVAC Page 1
?roject Title.......... Pasa Tiem o Plan 2/Casita Date..04/04/07 10:09:43
?roject Address........ 5th & Madison ******* ----------=-----------
La Quinta *v7.20*
)ocumentat.ion Author... Diane P. Mendoza ******* Building Permit #
D & R Calcs
14107 Ipava Drive Plan Check / Date
Poway, CA 92064.
858-486-9506 Field -Check/ Date
21imate Zone.... 15 ---------------------
:ompliance Method...... MICROPAS7 v7.20 for 2005 Standards by Enercomp, Inc.
----------------------------------------------- - --
MICROPAS7 v7.20 File-PSTMP2CR Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2/Casita
----------------------------------=--------------------------------------------
GENERAL INFORMATION
-------------------
Floor Area .................
Volume. .................
Front Orientation..........
Sizing Location........ ...
Latitude ....................
Winter Outside Design...:..
Winter Inside Design.......
Summer Outside Design......
Summer Inside Design.......
Summer Range.. .. .....
Interior Shading Used......
Exterior Shading.Used.......
Overhang.'Shading Used......
Latent Load Fraction.......
Description
3115 sf
32479 cf
Front Facing 0 deg (N).
PALM DESERT
33.7 degrees
26 F
70 F
111 F
75 F
34 F
Yes
Yes
Yes
0.24
HEATING AND COOLING LOAD SUMMARY
--------------------------------
Opaque Conduction and Solar......
Glazing Conduction and Solar.....
Infiltration:..... .... .......
Internal Gain ....................
Ducts........:..........I........
Sensible Load ....................
Latent Load .......................
Minimum Total Load
Heating Cooling
(Btu/hr) (Btu/hr)
-----------
29233
-----------
12324
9090
14340
11729
6781
n/a
2290
9240
7411
59292
43146
n/a
10398
59292 53545
Note: The loads shown are only one of. the criteria.affecting
of HVAC equipment. Other relevant de°sign factors such
requirements, outside air, outdoor design temperatures,
availability of equipment, oversizing safety margin, etc.,
considered.- It is the HVAC designer's responsibility to
factors when selecting the HVAC equipment.
the selection
as air flow
coil sizing,
Must also be
consider all'
[VAC SIZING HVAC Page 2
'rojec.t Title.......... Pasa Tiempo Plan 2/Casita Date..04/04/07 10:09:43
------------------------
MICROPAS7 v7.20; File-PSTMP2CR Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2/Casita
HEATING AND COOLING LOAD SUMMARY BY ZONE
------------- - --------------------------
ZONE 'LIVING'
Floor Area .......................
1541 sf
Volume ............................
16739 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
138.74
5832
Glazing Conduction and Solar...:.
4206
6293
Infiltration.:..... ....
5802
3355
Internal Gain..................
n/a
1122
Ducts....... ............ ......
4409'
3443
Sensible Load........... .......
28292
20045
Latent Load ..:...................
n/a
4831
Minimum Zone Load
28292
24876
ZONE 'SLEEPING'
Floor Area... ..................... 1574 sf
Volume ........................... 15740 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar ......
15359
'6491
Glazing Conduction and Solar,_...
4884
8047
Infiltration .....................
5927
3427
Internal Gain... ......
n/a
1168
Ducts.. ...........................
4831
3968
Sensible:Load.....................
31001
23101
,Latent Load .......................
n/a.
5567
Minimum Zone Load
31001
28668
[VAC SIZING HVAC Page 3
'roject Title.......... Pasa Tiempo Plan 2/Casita . Date..04/04/07 10:09:43
---------------------------------------------------=---------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP2CR Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2/Casita
------------------------------------------------------------------------------
GENERAL INFORMATION
Floor Area................. 3115 sf
Volume.............. 32479 cf
Front Orientation.......... Front Facing 90 deg (E)
Sizing Location............ PALM DESERT
Latitude ................... 33.7 degrees
Winter Outside Design...... 26 F
Winter Inside, Design....... 70 F
Summer Outside Design...... 111 F
Summer Inside Design....... 75 F
Summer Range.... ......... 34 F .
Interior Shading Used...... Yes
.Exterior Shading Used...... Yes
Overhang Shading,Used.....'. Yes
Latent Load Fraction....... 0.24
HEATING AND COOLING LOAD SUMMARY
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar...:..
29233
11575
Glazing Conduction and Solar......
9090
14921
Infiltration .....................
11729
6781
Internal Gain ....................
n/a
2290
Ducts ................... ... ...
92.40
7376
Sensible Load ..:.................
59292
42943
Latent Load... ... .......
n/a
10349
Minimum Total Load
59292
53292
Note: The loads shown are only one of the criteria affecting the.selection
of HVAC equipment. Other relevant design factors such `as air flow
requirements, outside air, outdoor design temperatures,coil sizing,
availability of equipment, oversizing safety margin,.etc., must also be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting,the HVAC equipment.
[VAC SIZING HVAC Page 4
'roject.Title........... Pasa Tiempo Plan 2%Casita. Date..04/04/07 10:09:43
'MICROPAS7 v7.20 File-PSTMP2CR Wth-CTZ15S05' Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2/Casita
HEATING AND COOLING LOAD SUMMARY BY ZONE
ZONE 'LIVING'
Floor Area ....................
1541 sf
Volume... ....................... .
16739 cf
Heating.
Cooling.
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar.......
13874
5721
Glazing Conduction and Solar.....
4206
6234
Infiltration .....................
5802
3355
Internal Gain ....................
n/a
1122 -
Ducts. .......... .. ... .........
4409
3408
Sensible Load .....................
28292
19839
Latent Load ........................
n/a
4781
Minimum Zone Load
28292
24621
ZONE 'SLEEPING'
Floor Area .......................
1574 sf.
Volume ...........................
15740 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
15359
5854
Glazing Conduction and Solar.....
4884
8686
Infiltration. ........ .....:..
5927
3427
Internal Gain ......................
n/a
1168
Ducts .............................
4831
3968
Sensible Load .............. ....
31001.
.23104
Latent Load .......................
n/a.
5568
Minimum Zone Load
31001
28672
IVAC SIZING HVAC Page.5
>roject Title.......... Pasa Tiempo Plan 2/Casita Date..04/04/07 10:09:43
-----------------
MICROPAS7 v7.20 File-PSTMP2CR Wth-CTZ15S05 Program-HVAC SIZING
User#.-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2/Casita
------------=------------------------------------------------------------------
GENERAL INFORMATION
Floor Area ..................
3115 sf
Volume. ..................
32479 cf
Front Orientation..........
Front Facing
180 deg (S)
Sizing Location............
PALM DESERT
Latitude .......:...........
33.7 degrees
Winter Outside Design......
26 F
Winter Inside Design.......
70 F
Summer Outside Design......'
111 F
Summer Inside Design.......
75 F.
Summer Range ...............
34 F
Interior Shading Used......
Yes
Exterior Shading.Used.......
Yes
Overhang Shading Used.......
Yes
Latent Load .Fraction .......
0.24
` HEATING AND COOLING
LOAD -SUMMARY
--------------------------------
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
29233
12321
Glazing Conduction and Solar.....
9090
14340
Infiltration ......................
11729
6781
Internal Gain. ......................
n/a
2290
Ducts......* ...................
9240
7410
Sensible Load ......................
59292
43142
Latent Load ......................
n/a
10397
Minimum Total.Load
59292
53539
Note,: The loads shown are only one of -'the criteria affecting the selection.
of HVAC equipment. Other relevant design factors such as air flow
requirements,, outside air, outdoor, design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It, is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
iVAC SIZING �HVAC Page 6
------------------
?roj-,ect Title.......... Pasa Tiempo Plan 2/Casita Date..04/04/07 10:09:43
-------------------------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP2CR Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2/Casita'
-------------------------------------------------------------------------------
HEATING AND COOLING LOAD SUMMARY BY ZONE
-----------------------------------------
ZONE 'LIVING'
Floor Area........................ 1541 sf
Volume................ 16739 cf
Heating-
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
13874
5819
Glazing Conduction and Solar......
4206
6293
Infiltration .....................
5802
3355
Internal Gain ........................
n/a
1122
Ducts. ............... .....
.4409
3440
Sensible Load....... ...........
28292
20029
Latent Load ......................
n/a
4827
Minimum Zone Load-
28292
24856
ZONE 'SLEEPING'
Floor Area.......................
1574 sf
Volume ...........................
15740 cf
Heating
Cooling
Description
.(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
15359
6501
Glazing Conduction and Solar.....
4884
8047
Infiltration.... ...............
5927
3427
Internal Gain. .. .. .........
n/a
1168
Ducts. ............... ........
4831
3970
Sensible Load. ..................
31001
23113
Latent Load...........11 ...........
n/a
5570
Minimum Zone Load
31001
28683
[VAC SIZING HVAC Page 7
_'roject Title ........ .:..Pasa Tiempo Plan 2/Casita Date..04/04/07.10:09:43
---------------------------------------------------------
MICROPAS7 v7 20 File-PSTMP2CR. Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 2/Casita
GENERAL INFORMATION
-------------------
Floor Area .................
3115
sf
Volume .....................
32479
cf
Front Orientation..........
Front
Facing.270
Sizing Location............
PALM
DESERT
Latitude... ..............
33.7
degrees
Winter Outside'Design......
26 F
Winter Inside Design.......
70 F
-
Summer Outside Design......
111 F
Summer Inside Design.......
75 F
Summer Range ...............
34 F
Interior Shading Used......
Yes
Exterior Shading Used......
Yes
Overhang Shading Used......
Yes
Latent Load Fraction.......
0.24
-
HEATING AND COOLING LOAD SUMMARY
Heating
Description.
(Btu/hr).
Opaque Conduction and Solar......
29233
Glazing Conduction and Solar.....
9090
Infiltration ......................
11729
Internal Gain ....................
n/a
Ducts ............................
9240
Sensible Load ................ ..
59292
Latent Load ......................
n/a
Minimum Total Load
59292
deg (W)
Cooling
(Btu/hr)
11632
14921
6781
2290
7388
43013
10366
53379
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors .such as air flow
requirements, outside air, outdoor design temperatures, coil -sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It is the HVAC designer's responsibility to. consider all
factors when selecting the HVAC equipment.
[VAC SIZING
HVAC Page 8
Iroject Title.......... Pasa Tiempo Plan 2/Casita
Date..04/04/,07 10:09:43
MICROPAS7 v7.20 File-PSTMP2CR Wth-CTZ15S05
Program-HVAC
SIZING
User#-MP0864 User-'D & R Calcs Run-'Pasa
Tiempo
Plan 2/Casita
HEATING.AND.COOLING LOAD
----------------------------------------
SUMMARY BY
ZONE
ZONE 'LIVING'
Floor Area ...................
1541 sf
Volume............ ..........:.....
16739 cf
Heating.'
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
13874
5689
Glazing Conduction and Solar.....
.4206
6234
Infiltration......... .........
5802
3355
-Internal Gain .............
n/a.
1122
Ducts ............................
4409
3401
Sensible Load.. ...................
..28292
i9801
Latent Load... .......... .......
n/a
4772.
Minimum Zone Load
28292
24573
ZONE 'SLEEPING'
Floor Area.... .................
1574 sf
Volume....... ..................
15740 cf
Heating
Cooling .
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
15359
5944
Glazing Conduction and Solar.....
4884'
8687
Infiltration.... ..................
5927
3427
Internal Gain... .............
n/a
1168
Ducts ..............................
4831
3987
Sensible Load ....................
31001
23212
Latent Load......... ..........
n/a
5594
Minimum Zone Load
31001
28806
i
PASA .. TIEMPO
PLAN 3 w/ CASITA
LA QUINTA, CA
CLIMATE ZONE 15
D & R Calcs',
Title 24 Energy.Calculations
Micropas v7.20 Performance Method
July 16., 2007
ThTLE 24 COMPLIANCE REQUIREMENTS SUMMARY-
PASA Tiempo Plan 3 w/ Casita
r
Ceiling Insulation = R-30 min. PROVIDE RADIANT BARRIER ROOF SHEATHING
(NOTE ON PLANS)
Wall Insulation = R-19 min.
Floor. Insulation = n/a
Thermal Mass Areas See floor plan.
Glazing = All windows & doors to be dual glass. All glass is Low E.-
Glazing shall be installed with a NFRC certifying label
attached showing Uvalue.
Solar Heat Gain Co -efficient = 0-.35 dual windows & doors
UValue = 0.40 vinyl/wd windows & doors
Owner to purchase windows & doors w/ specified Uvalues & SHGC's or better.
Hot Water Heater = (1) 75 gal A. O. Smi th #BTC-251- * * * or eq. : Standby
Loss is 2.0 min. Provide a recirc pump.
Infiltration = Standard
AFUE
- 0. 78 (e)
SEER - 13. 0 min WITH TXV - HERS- VERIFIED
Duct
Insulation =
R-4.2 min. PROVIDE DUCT
TESTING BY A HERS RATER
Heater sizing
Zone
1."LIVING"
Sensible heat load -
28,311 Btu
(Verify HVAC-equip.
w/ Mechanical)
Zone.2
"SLEEPING"
Sensible heat load -
26,641 Btu
(Verify HVAC equip.
w/ Mechanical)
A/C Sizing
Zone
1 "LIVING"
Sensible cool'g load
=:20,053 Btu. '
Latent cool'g load
='.4,833 Btu
Zone
2."SLEEPING"
Sensible cool'g load
= 17,939 Btu
Latent cool'g load
= 4,323 Btu
Verify HVAC sizing & equipment with a Mechanical.Engineer/Contractor.
Owner may install any Make & Model HVAC equipment that is equal or greater
than the minimum efficiencies.listed above. All equipment is listed "or eq"
CERTIFICATE OF
COMPLIANCE: RESIDENTIAL COMPUTER METHOD
CF-1R
Page 1
---------------------------------------------=---------------------------------
-------------------------------------------------------------------------------
Project Title..........
Pasa Tiempo Plan 3/Casita
Date..07/16/07.14:25:17
Project Address........
5th & Madison
*******
---------------=------
La Quinta
*v7.20*
Documentation Author...
Diane P. Mendoza
*******
Building Permit #
D & R Calcs
14107 Ipava Drive
Plan Check %.Date
Poway; CA 920.64
858-486-9506
Field Check/
Date
Climate Zone...........
15
---------------------
Compliance Method.......
MICROPAS7 v7.20 for 2005
Standards
by Enercomp,
Inc.
MICROPAS7
v7.20
File-PSTMP3CR Wth-CTZ15S05
Program-FORM.CF-1R
User#-MP0864
User-D & R,Calcs Run-Pasa
Tiempo
Plan 3/Casita
_.
MICROPAS7 ENERGY USE SUMMARY
=
= Energy Use
----------------------------
Standard Proposed
Compliance =
_ (kTDV/sf-yr)
------------------------
Design.
-------------------
Design
Margin. _
-
= Space
Heating..........
1.83
1.84
----------
-0.01 =
- Space
Cooling..........
64.69
62.37
2.32 =
= Water
Heating..........
8..25
8.51
-0.26 =
_
North
Total 74.77
72.72
2.05 =
- Space
Heating..........
. 1.83
2.19
-0.36 =
- Space
Cooling
............ 64.69
61.32
3.37 =
= Water
Heating..........
.. 8.25
8.51
-0.26 =
=
East Total' 74.77
72.02
2.75 =
= Space
.Heating
.......... 1.83
2.34
-0.51 =
_ Space
Cooling..........
64.69
61,33
3.36 =
= Water
Heating.
....... 8.25
8.51
-0.26 =
=
South Total 74.77
72.18
2.59 _
= Space
Heating...
.... 1.83
1.95
-0.12 =
= Space
Cooling........
64.69
60.10
4.59 =
_ Water
Heating.......
.. 8.25
8.51
-0.26 =
_
West Total 74.77
70.56
4.21 =
Building complies with Computer
Performance
_ *** HERS
Verification Required for
Compliance****._
CERTIFICATE OF COMPLIANCE: RESIDENTIAL_COMPUTER METHOD CF-1R Page 2
Project Title.......... Pasa Tiempo Plan 3/Casita Date..07/16/07 ,14:25:17
-------------------------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP3CR Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa.Tiempo Plan 3/Casita I'
---------------------------------------=---------------------------------------
GENERAL INFORMATION
HERS Verification........... Required
Conditioned Floor Area...... 3113 sf
Building Type., ............ Single Family Detached
Construction Type .......... New
Fuel.Type ................ NaturalGas"
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units.... 1
Number of Building Stories. 1
Weather Data Type..;....... FullYear
Floor -Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
.Average Glazing U-factor...
Average.Glazing SHGC.......
Average Ceiling Height.....
lone Type
---------------
JIVING
Residence
-)LEEPING
Residence
jurf ace
------------
'JIVING
1
Door
2
Wall
4
Wall
5
Wall
8
Wall
-.0
Wall
_..2
RoofRad .
LEEPING
3
Wall
6
Wall
Slab On Grade
2
32534 cf
31'13 sf
15.5 % of floor area
0.4 Btu/hr-sf-F
0.35
10.5 ft
BUILDING ZONE INFORMATION
Floor # of # of Cond- Thermo- 'Vent Vent Verified
Area Volume Dwell Peop- it: stat Height Area Leakage or
(sf) (cf) Units le ioned Type (ft). (sf). Housewrap
---- ------ ---=- ----- ------------- ----------------------
1658 17984
1455 14550
Frame Area
Type (sf)
U-
fact-
or
0.53 1.6 Yes Setback 2.0 Standard No
0.47 1.4 Yes Setback 2.0 Standard No
OPAQUE SURFACES
---------------
Sheath Solar Appendix
Cavity ing Act Gains IV Location/
R-val R-val Azm Tilt Reference Comments
Wood
24
0.500
0
0
315
90
Yes
IV.5
A4
Wood
126
0.074
19
0
0
90,Yes
IV.9
A5
Wood
75
0.074
19
0
90
90
Yes
IV.9
A5
Wood
90
0.074
19
0
90
90
No
IV.9
A5
Wood
244
0.074
.19
.0
180
90.Yes
IV.9
A5
Wood
518
0'.074
19
0
270
90
Yes
IV.9
A5
Wood
1658
0.032
30
0
n/a
0
Yes
IV.1
A7
Wood
390
0.074
19
0
0
90
Yes
IV.9
A5
Wood
495
0.074
19
0
90
90
Yes
IV..9
A5
-'ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3
---------------------------------------------------=---------------------------
-------------------------------------------------------------------------------
?roject Title.......... Pasa Tiempo Plan 3/Casita Date..07/16/07 14:25:17
-----------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP3CR Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 3/Casita
-------------------------------------------------------------------------------
Surface
------------
7 Wall
9 Wall
'-1 Wall
-3 RoofRad
Surface
LIVING
14 SlabEdge
SLEEPING
15 SlabEdge
'lrientation
OPAQUE SURFACES
U- Sheath- Solar Appendix
Frame Area fact- Cavity ing Act Gains IV Location/
Type (sf) or. R-val R-val Azm Tilt Reference Comments
- --- ---- -- -- ----- ----- --- ---- --- --------- --------------
Wood 148 0.'074 19 0 90 90 No IV.9 A5
Wood 157 0.074 19 0 180 90 Yes IV.9 A5
Wood .200 0.0.74 19 0 270 90 Yes IV.9 A5
Wood 1455 0.032 30 0 n/a. 0 Yes IV.1•A7
PERIMETER LOSSES
----------------
Appendix
Length F2 Insul Solar IV. Location/
(ft) Fact.or R-val Gains Reference Comments
136 0.730 R-0 No IV.26 Al
158 0.730 R-0 No IV.26 Al
,IVING
L Door Front (N) ,
2 Wind Left (E)
6 Door Back (S)
7-Wind Back (S)
y0 Door Right (W)
1 Wind Right (W)
.2 Wind Right (W)
-'LEEPING
3 Wind Left (E)
4 Wind Left (E)
5 Wind Left (E)
8 Door Back ( S )
9 Wind Back. (S)
,3 Door Right (W)
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
(sf) factor SHGC,Azm Tilt Type Location/Comments
40.0 0.400 0.350 0 90 Standard FRONT/Vinyl/Wd Dr LoE
25.0 0.400 0.350 90 90 Standard LEFT/Vinyl/Wd Op LoE
96.0 0.400 0.350 180 90 Standard BACK /Vinyl/Wd Dr LoE
30.0 0.400 0'.350 180 90 Standard BACK1/Vinyl/Wd Op LoE
40.0 0.400 0.350 270 90 Standard RIGHT/Vinyl/Wd Dr LoE
45.0 0.400 0.350 270 90' Standard RIGHT1/Vinyl/Wd Op LoE.
12.0 0.400 0.350 270 90 Standard RIGHTII/Vinyl/Wd Op.,-LoE
6.0 0:4,00 0.350 90 90 Standard LEFTIR/Vinyl/Wd Op LoE
.4.0 0.400 0.350 90 90 Standard LEFT2/Vinyl/Wd Op LoE
75.0 0.400 0.350 90. 90 Standard LEFT21/Vinyl/Wd Op LoE
64.0 0.400 0.350 180. 90 Standard BACK2/Vinyl/Wd.Dr LoE
4.0 0.400 0.350 180 90 Standard BACK21/Vinyl/Wd Op LoE
40.0 0.400.0.350 270 90 Standard RIGHT2/Vinyl/Wd Dr LoE
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4
-----------------
-----------------.------------------------------------------------------------_
Project Title........... Pasa Tiempo.Plan 3/Casita. Date..07/16/07 14:25:17
-------------------------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP3CR Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 3/Casita
-------------------------------------------------------------------------------
OVERHANGS
---Window---
--------------
Overhang ------------
Area
Left
Right
Surface
(sf).Width
-----
Height
Depth
Height
Extension
Extension
-----------
LIVING
------
------
-----
------
---------
---------
1
Door
40.0
n/a
8.0
10.0
0.0
n/a
n/a .
.2
Window
25.0
n/a
5_0
8.0
1.0
n/a
n/a
6
Door
96.0
n/a
8.0
11.5
1.0
n/a
n/a
7
Window
30.0
n/a
5.0
1.5
2.0
n/a
n/a
10
Door
40.0
n/a
8.0
8.5
0.0
n/a
n/a _
11
Window
45.0
n/a
5..0,
1.5
2.0
n/a
n/a'
12
Window
12.0
n/a
2.0
1.5
2.0
n/a
n/a
SLEEPING
3
Window
6.0
n/a
3.0.
1.5
2.0
n/a
n/a
4
Window
4.0
n/a
2.0
1_5
2.0
n/a
n/a
5
Window
75.0
n/a
5.0
1.5
2.0
n/a'
n/a
8
Door
64.0
n/a
8.0
1.5
2'.0
n/a
n/a
9
Window
4.0
n/a
.2.0
5.0
1.0
n/a
n/a
.13
Door
40.0
n/a
8.0
8.5
0.0
n/a
n/a
SLAB SURFACES
-------------
Area
Slab Type
(sf)
LIVING
Standard Slab 1658
SLEEPING
Standard Slab 1455
HVAC SYSTEMS
Verified
Number
Verified
Verified
Verified
Verified
Maximum
System
of
Minimum
Refrig Charge
Adequate
Fan Watt -Cooling
Type
Systems
Efficiency
EER
or TXV-
Airflow
Draw
Capacity
' ,IVING
Furnace
1
0.780 AFUE
n/a
n/a
n/a
n/a
n/a
ACSplit
1
13.00 SEER-
No
Yes
No
No
No
"LEEPING
Furnace
1
0.780 AFUE
n/a
n/a
n/a
n/a
n/a
ACSplit
1
13.0.0 SEER
No
Yes
No
No
No
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5
----------------------------------
Project Title.......... Pasa Tiempo Plan 3/Casita Date..07/16/07 14:25:17,
--------------------------------------------------------=====------------------
MICROPAS7 v7.20 File-PSTMP3CR Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 3/Casita
--------------------------------------=----------------------------------------
HVAC SIZING
r
Verified
Total
Sensible
Design
Maximum
Heating
Cooling
Cooling
Cooling
System
Load
Load
Capacity
Capacity
Type
-------------
(Btu/hr)
--------
(Btu/hr)
(Btu/hr)
(Btu/hr)
LIVING
-
-----------
--------------------
p
Furnace
28311
n/a
n/a
n/a
ACSplit
n/a
20948
25996
n/a,
SLEEPING
Furnace
26641
n/a
n/a
n/a,
ACSplit
n/a
18797..
23328
n/a
Total
549,52
39745
49324
n/a
Orientation of
Maximum.....
Front Facing
180 deg (S)
Sizing
Location............
PALM DESERT -
Winter
Outside
Design.......
26 F
Winter
Inside Design::.....
70 F
Summer
Outside
Design......
111 F
Summer
Inside Design.:.....
75 F
Summer
Range ....:..........
34 F'
DUCT SYSTEMS
Verified
Verified
Verified
System
Duct
Duct
Duct
Surface
Buried
Type
Location
R-value
Leakage
Area
Ducts
LIVING
Furnace
Attic
R-4.2
Yes
No
No
ACSplit
Attic
R-4.2
Yes
No
No
SLEEPING
Furnace
Attic
R-4.2
.Yes
No
No
ACSplit
Attic
R-4.2
Yes
No
No
WATER HEATING SYSTEMS
Number Tank External
Heater in Energy Size Insulation
-'ank'Type Type Distribution Type System Factor (gal) R-value
------------------------------------------ -------------- ----------------
1 Large Gas Recirc/Demand 1 n/a 75 R-n/a
i
_'ERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6
-----------------=-----------------------------------------------------=--------
-------------------------------------------------------------------------------
?roject Title.......... Pasa Tiempo Plan 3/Casita Date..07/16/07 14:25:17
----------------------------------=--------------------------------------------
-------------------------------------------------------------------------------
' MICROPAS7 v7.20 File-PSTMP3CR Wth-CTZ15S05 Program -FORM CF-1R`
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 3/Casita
-------------------------------------------------------------------------------
WATER HEATING SYSTEMS DETAIL'
----------------------------
Standby Internal Tank
Recovery .Rated Loss. Insulation Pilot
System Efficiency Input. Fraction R-value 'Light
1 Large 0.19 n/a 0.02 R- n/a n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection'. ***
,his building incorporates a HERS verified Refrigerant Charge test
jr a HERS verified Thermostatic Expansion Valve (TXV). If a
:ooling system is not installed, then HERS verification is not necessary.
this building incorporates HERS verified Duct Leakage.
,his is a multiple orientation building. This printout is for the front
'acing North.
-'his building incorporates'a Radiant Barrier.
'his building incorporates a non-standard Water Heating System. '
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision'of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods.and ***
*** must .be.reported on the CF-4R installation certificate. ***
.'his building incorporates a HERS verified Refrigerant Charge test
)r a HERS veri.fied Thermostatic Expansion Valve (TXV). If a
pooling system is not installed, then HERS verification is not necessary.
'his building incorporates HERS verified Duct Leakage. Target leakage.is
:alculated and documented on the CF-4R. If the measured CFM -is above the
..arget, then corrective action must be taken to reduce the duct leakage and
hen must be retested. Alternatively, the compliance calculations could be
-edone without duct testing. If ducts are not installed, then HERS
%erification.is not necessary.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD- CF-1R- Page 7
------------------------
Project Title........... Pasa Tiempo Plan 3/Casita Date..07/16/07.14:25 17.
----------------------------------------------------------
MICROPAS7 v7. 20 File=PSTMP3CR Wth-CTZ15S05 Program -FORM CF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 3/Casita
REMARKS
Verify HVAC sizing & equipment-w/ Mechanical engineer/,contractor..
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications 'needed to comply with Title-24, Parts 1 and 6'of the
California Code of Regulations, and 'the administrative regulations to
implement them. This certificate has been signed.by the individual with
overall design responsibility.
DESIGNER or OWNER DOCUMENTATION AUTHOR
Name.... Bill Currier Name_.. Diane P. Mendoza
Company..Colbourn Currier Noll Company. D & R Calcs
Address. 10675 Treena Street 410.1 Address. 14107 Ipava Drive
San Diego, CA 92031 Poway, CA 92064
Phone... (858) 695=1914 Phone... 858-.48:6-9506 "
License.
Signed.. Signed.. �� �' �� Z1%
(date) (date)
ENFORCEMENT.AGENCY
Name....
Title...
Agency..
Phone...
Signed.:
(date)
,MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page,1
-------------------------------------------------------------------------------
?roject Title.......... Pasa Tiempo Plan 3/Casita Date..07/16/07 14:25:17.
?roject Address........ 5th & Madison ******* ---------------------
La Quinta *v7.20*
)ocumentation Author... -Diane P. Mendoza ******* Building Permit #
D & R Calcs
14107 Ipava Drive Plan Check / Date
Poway, CA 92064
858-486-9506 Field Check/.Date
'-limate Zone........... 15 ---------=-----------
-ompliance Met.hod...... MICROPAS7 v7.20 for 2005 Standards by Enercomp, Inc.
------------=------------------------------=-----------------------------------
--------------------------------------------------------------------------------
MICROPAS7 v7.'20 File-PSTMP3CR Wth-CTZ15S05 Program -FORM MF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 3/Casita
------------------ ----------------------------------------------------=--------
Tote: Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. More stringent compliance
-equirements from the Certificate of Compliance supersede the items marked with
in asterisk (*). When this checklist is incorporated into the permit documents,.
-:he features noted shall be considered by all parties as minimum component
performance specifications for the mandatory measures whether.they are shown
!lsewhere in the documents or on this checklist only.
3UILDING ENVELOPE MEASURES
150(a): Minimum R-19 insulation in wood framed ceiling or
De- En-
sign force-
n/a er ment
equivalent U-factor in metal frame ceiling
/
150(b): Loose fill insulation manufacturer's labeled R-Value
150(c): Minimum R-13 wall insulation in wood framed walls or
equivalent U-factor in metal frame walls (does not apply
to exterior mass walls)
✓-
150(d): Minimum R-13 raised floor insulation in framed floors
or equivalent U-factor ✓
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and.factory-built fireplaces have:
a: Closeable metal or glass door covering the entire
opening of the firebox
/
b. Outside air intake with damper and control, flue
damper and control
/
2. No'continuous burning gas pilot lights allowed
/
150(f): Air retarding wrap installed to comply with Sec..151
meets requirements specified in ACM Residential,Manual /
150(g): Vapor barriers mandatory in Climate Zones 14,16 only
150(1): Slab edge insulation - water absorption rate for the
insulation material without facings no greater than 0.3%,
water vapor permeance rate no greater than 2.0 perm/inch
118: Insulation specified or installed meets insulation quality
standards. Indicate type and include CF-6R form
116-17: Fenestration Products, Exterior Doors and Infiltration/
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage
2. Fenestration products (except field. -fabricated) have
RANDATORY MEASURES CHECKLIST: RESIDENTIAL
MF-1R Page 2
--------------------------------------------------------------------------------
-------------------------------------------------------------------------------
?roject Title...:...... Pasa Tiempo Plan 3/Casita Date..07/16/07 14:25:17
-------------------------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP3CR Wth-CTZ15S05 Program -FORM MF-1R
User#-MP0864 User=D & R Calcs Run-Pasa Tiempo Plan 3/Casita
-------------------------------------------------------------------------------
label with certified U-factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed
'PACE' CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
n/a
110-113: HVAC.equipment, water heaters, showerheads and
faucets certified by the Energy"Commission
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA
150(i): Setback thermostat on all applicable heating and/or
cooling systems
150(j): Water system pipe and tank insulation and cooling
systems line insulation
J . Storage gas water heaters -rated with an Energy Factor
less than 0.58 must,be externally wrapped with insulation
having an installed thermal resistance of R12 or greater
2. Back-up tanks for solar system, unfired storage tanks, or
other indirect hot water tanks have R-12 external
insulation or R-16 internal and indicated on the
exterior of the tank showing the R-value
3. The following piping is insulated according to Table 150-A/B
or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to
water heater tank, non -recirculating systems, and
entire length of recirculating sections of, hot water
pipes shall. be insulated to Table 150B
2. Cooling system piping (suction, chilled water, or
brine lines), piping insulated between heating source
and indirect hot water tank shall be insulated to
Table 150-B and Equation 150-A
De- En-
sign- force
er ment
M
l
4. Steam hydronic heating systems or not water systems >15 psi,
meet requirements of Table 123-A
5. Insulation must be protected from damage, including that due
to sunlight, moisture; equipment maintenance and wind z�
6. Insulation for chilled water piping and refrigerant suction
piping includes a vapor retardant or is enclosed entirely
in conditioned space
7. Solar water -heating systems/collectors are certified by thy/
Solar Rating and Certification Corporation
'150 (m) : Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to
meet the requirements of the CMC Sections 601, 602, 603,
604, 605 and Standard 6-5; supply -air and return -air ducts
and plenums are insulated to a minimum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings
shall be sealed with mastic, tape, or other duct -closure
system that meets the applicable requirements of UL 181,
4ANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 3
-------------------------------------------------------------------------------
?roject Title.......... Pasa Tiempo Plan 3/Casita. Date..07/16/07 14:25:17
-------------------------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP3CR Wth-CTZ15S05 Program -FORM MF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 3/Casita
-------------------------------------------------------------------------------
UL 181A, or UL 181B or aerosol sealant that meets the
requirements of UL 723. If mastic or tape is used to seal
openings greater than 1/4 inch, the combination of mastic
and either mesh or tape shall be used
2. Building cavities, support platforms for air handlers, and
plenums defined or constructed with materials other than
sealed sheet metal, duct board or flexible duct shall not
be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in
cavities and support platforms shall not be compressed to cause
reductions in the cross -sectional area of the ducts
3. Joints and seams of duct systems and their components
shall not be sealed with cloth backed rubber adhesive
duct tapes unless such tape is used in combination with f
mastic and draw bands
4. Exhaust fan systems have back draft or automatic dampers
5. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
operated dampers
6. Protection of Insulation. Insulation shall be protected
from damage due to sunlight, moisture, equipment mainten-
ance and wind. Cellular foam insulation shall be protected
as above or painted with a coating that is water retardant
and provides shielding from solar radiation that can cause
degradation of the material
7. Flexible ducts cannot have porous inner cores
114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with.the Appliance
Efficiency Regulations, on -off switch mounted outside of
the heater, weatherproof operating instructions, no
electric resistance heating and no pilot light
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for future solar heating
b. Cover for outdoor pools or out spas.
3. Pool system has directional inlets and a circulation
pump time switch
115: Gas -fired central furnaces, pool heaters,.spa heaters or
household cooking appliances have no continuously burning
pilot light (Exception: Non -electrical -cooking appliances
with pilot < 150 Btu/hr)
118(i): Cool Roof material meets, specified criteria
RESIDENTIAL LIGHTING MEASURES De- En-
sign- force
n/a er ment
150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID:
contain only high efficacy lamps as outlined in Table
150-C, and do not contain a medium screw base socket
(E24/E26). Ballast for lamps 13 watts or greater are electronic /
and have an output frequency no less than 20 kH-z
_4ANDATORY MEASURES CHECKLIST: RESIDENTIAL
MF-1R Page 4
-------------
Project Title........... Pasa Tiempo Plan 3/Casita Date..07/16/07 14:25:17
MICROPAS7 v7.20 File=PSTMP3CR Wth-CTZ15S05 Program -FORM MF-1R
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 3/Casita
150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain
only high efficacy lamps as outlined in Table 150-C,
luminaire has factory installed HID ballast
150(k)2: Permanently installed luminaires in kitchens shall
be high efficacy luminaires. Up to 50 percent of the wattage,
as determined in Sec. 130(c), of permanently installed luminaires
in kitchens may be in luminaires that are not high efficacy
.luminaires, provided.that these luminaires are controlled
by switches separate from those controlling the high
efficacy luminaires
L50(k)3: Permanently installed luminaires in bathrooms,
garages, laundry rooms, utility rooms shall be high
efficacy luminaires OR are controlled by an occupant
sensor(s) certified to comply.with Section 119(d) that
does not turn on automatically or have an always on option
-,_50(k)4: Permanently installed luminaires located other than
in kitchens, bathrooms, garages, laundry rooms, and utility
rooms shall be high efficacy luminaires (except closets
less than 10 ft2), OR are controlled by a dimmer switch
OR are controlled by an occupant sensor(s) that complies
with Section 119(d) that does not turn on automatically
or have an always on option
.50(k)5: Luminaires that are recessed into insulated ceilings
are approved for zero clearance insulation cover (IC) and
are certified air tight to ASTM E283 and labeled as air
tight (AT) to less than 2.0 CFM at 75 Pascals
.50(k)6: Luminaires providing outdoor lighting and permanently
mounted to a residential building or.to other buildings on
the same lot shall be high efficacy luminaires (not in-
cluding lighting around swimming pools/water features or
.other Article 680 locations) OR are controlled by occupant
sensors with integral photo control certified to comply
with Section 119(d)
,50(k)7: Lighting for parking lots for 8 or more vehicles shall
have lighting that complies with Sec. 130, 132, and 147.
Lighting for parking garages for 8 or more vehicles shall
have lighting that complies with Sec. 130, 131, and 146
_50(k)8: Permanently installed lighting in the enclosed, non -
dwelling spaces.of low-rise residential buildings with four /
or more dwelling units shall be high efficacy luminaires OR
are controlled by an occupant sensor(s) certified to
comply with Section 119(d)
i,
HVAC SIZING
HVAC
Page 1
--------------------
Project Title.......... Pasa Tiempo.'Plan 3/Casita Date..07/16/07 14:25:17:
Project Address........ 5th & Madison
******* -------------------
7-
La Quinta
*v7.20*
Documentation Author.:. Diane P. Mendoza
*******
Building Permit.#
D & R Calcs
14107 Ipava Drive
Plan Check /-
Date
Poway, CA 92064
8587486-9506
Field Check/
Date
_"limate Zone:..:....... 15
---------------------
-ompliance Method...... MICROPAS7 v7.20 for
2005 Standards by Enercomp,
Inc:
-----------------------------------------------------------------
MICROPAS7.v7.20 File-PSTMP3CR Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 -User-D & R Calcs Run-Pasa-Tiempo Plan 3/Casita
GENERAL INFORMATION
-------------------
Floor Area...
3113 sf
Volume .....................
32534 cf
Front Orientation..........
Front Facing O'deg (N):
Sizing Location............
PALM DESERT
Latitude...................
33.7 degrees
Winter Outside Design......
26 F
Winter Inside Design.......
70 F
Summer Outside Design......
111 F
Summer In Design........
75 F
Summer Range. ...... .....
34 F
Interior Shading Used ......
'Yes
Exterior Shading Used....:.
Yes..
Overhang Shading Used.::...
Yes
Latent Load Fraction.......
0.24
HEATING AND COOLING LOAD SUMMARY
Heating
Description
(Btu/hr)
Opaque Conduction and Solar......
26201
Glazing Conduction and Solar.....
8466
Infiltration........ ...........
.11721
Internal Gain .... ...... ........
n/a
Ducts.. ... ......... ... .....
8564
Sensible Load... ........:......
54952'
Latent Load........ ...............
n/a
Minimum Total Load
54952
Cooling
(Btu/hr)
10992
12804
6777
2290
6815
.39678
9563
49241
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outside air, outdoor design .temperatures coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It 'is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
-1VAC SIZING HVAC 'Page 2
-----------------------
Project Title.:........ Pasa Tiempo Plan 3/Casita Date..07/16/07 14:25:17
-----------------------------------------------------------------
MICROPAS7 v7..20 File-PSTMP3CR Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 3/Casita
HEATING AND COOLING LOAD SUMMARY BY ZONE
----------------------------------------
ZONE 'LIVING'
Floor Area ............... ......
1658 sf
Volume ...........................
17984 cf,
Heating
Cooling
Description
(Btu/hr)
.(Btu/hr)
Opaque Conduction and Solar.......
12587
5441
Glazing Conduction and Solar.....
5069
7093
.Infiltration... .....:.............
.6243
3609
Internal Gain............. .....
n/a
1214
Ducts .. .........................
4412
3600
Sensible Load:, .... .. .........
28311
.20956
Latent Load........ .....
n/a
5050
Minimum Zone Load
28311
26007
ZONE 'SLEEPING'
Floor Area............ ......... 1455 sf
Volume ..:........................ 14550 cf
Heating.
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
13614
5552
Glazing.Conduction-and Solar.....
3397
5711
Infiltration ......................
5478
3168
Internal Gain ................ ..
n/a
1076
Ducts............ ......... .......
4152
3216
Sensible Load .....................
26641
18722
Latent Load ......................
n/a
4512
Minimum Zone Load
26641
23234
iVAC SIZING HVAC Page 3
----------------------------
7
3roject Title.......... Pasa Tiempo Plan 3/Casita Date..07/16/07 14.:25:17.
-------------------------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP3CR Wth-CTZ15S05 Program-HVAC SIZING
J User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 3/Casita
------------------'------------------------------------------------------------
GENERAL INFORMATION
-------------------
Floor Area .................. 3113 sf
Volume..... 32534 cf
Front Orientation.......... Front Facing 90 deg (E)'
.Sizing'Location............ PALM DESERT
Latitude........... 33.7 degrees
Winter Outside.Design...... 26 F
Winter Inside Design....... 70 F
Summer Outside Design...... 111 F
Summer Inside Design....... 75 F
Summer Range .............. .. 34 F
Interior Shading.Used..... Yes
Exterior Shading Used....... Yes
Overhang Shading Used.... Yes.
Latent Load Fraction....... 0.24
HEATING AND COOLING LOAD.SUMMARY
---------------------------------
Heating Cooling
Description (Btu/.hr) (Btu/hr)'
--------------------------------------------------- ---
Opaque Conduction and Solar...... 26201 10710
Glazing Conduction -and Solar..... 8466 11625
Infiltration..................... 11721 6777
Internal."Gain........... _ ........... n/a 2290
Ducts .................. 8564 6513
Sensible Load............ ...... 54952 37915
Latent Load ....................... n/a 9138
Minimum Total Load 54952 47053
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also_ be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
r
iVAC SIZING HVAC Page 4
----------------
Project Title ............ Pasa Tiempo Plan 3/Casita Date..07/16/07 14:25:17
MICROPAS7 v7:20 File-PSTMP3CR Wth-CTZ15S0.5 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 3/Casita
-------------------'-------------------------------------.-----------------------
HEATING AND COOLING LOAD SUMMARY BY ZONE
ZONE 'LIVING'
Floor Area .....................
1658 sf
Volume ...........................
17984 cf
Heating
Cooling
Description
---------------------------------
(Btu/hr)
-----------
(Btu/hr)
-----------
Opaque Conduction and Solar......
12587
5200
Glazing Conduction and Solar.....
5069
6444
Infiltration .....................
6243
3609
Internal Gain....... ............
n/a
1214
Ducts ..... ....................
4412
3415
Sensible Load..... .............
28311
19883
Latent Load...... ...........
n/a
4792
Minimum Zone Load,
-----------
28311
-----------
24674
ZONE 'SLEEPING'
Floor Area .......................
1455 sf
Volume. ............._...... .. .
14550 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
,.Opaque Conduction and Solar......
13614
5511
Glazing Conduction and Solar.....
3.397
5181
Infiltration .....................
5478
3168
Internal Gain .....................
n/a
1076
Ducts ...............................
4152
3097
Sensible Load ....................
26641
18033
Latent Load ........................
n/a
4346
Minimum Zone Load
26641
22379
iVAC SIZING HVAC Page 5
--------------------------------------------------------------------------------
?roject Title.......... Pasa Tiempo Plan 3/Casita Date..07/16/.07 14:2.5:17
---=---------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP3CR Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo.Plan 3/Casita
-------------------------------------------------------------------------------
GENERAL INFORMATION
-------------------
Floor Area. .............. 3113 sf
Volume ..................... 32534 cf.
t Front Orientation.......... Front Facing 180 deg (S)
Sizing Location .............. PALM DESERT
Latitude ................... 33.7 degrees
Winter Outside Design:..... 26 F
Winter Inside Design....... 70 F
Summer Outside Design....... 111 F
Summer Inside Design........ 75 F
Summer Range....... ...... 34• F
Interior Shading Used....... Yes'
Exterior Shading Used...... Yes.
Overhang Shading -Used...... Yes
Latent Load Fraction....... 0.24
HEATING AND COOLING LOAD SUMMARY
----------=---------------------
Heating Cooling
Description (Btu/hr) (Btu/hr)
-------------------------------------------------------
Opaque Conduction and Solar...... 26201 11047
Glazing Conduction and Solar..... 8466 12804
s Infiltration............ ........ 11721 6777
Internal Gain ..................... n/a 2290
Ducts............ .............. 8564 6827
Sensible Load .................... 54952 39745
Latent Load....... ................ n/a 9579
----------------------
Minimum Total Load 54952 49324
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements; outside air, outdoor 'design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc.,, must also be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
iVAC SIZING HVAC Page. 6
--------------------
Project Title.......... Pasa Tiempo Plan 3/Casita Date..07/16/07 14:25:17
------- - - - ---- ---------------- ----
MICROPAS7 v7.20 File-PSTMP3CR Wth-CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan 3/Casita
HEATING AND COOLING LOAD SUMMARY BY ZONE
--------------------------------------
ZONE 'LIVING'
Floor Area ..................:.... 1658.sf
Volume .............. ............ 17984 cf
Heating
Cooling
Description
---------------------------------
(Btu/hr)
-----------
(Btu/hr)
-----------
Opaque Conduction and Solar......
12587
5434
Glazing Conduction and Solar.....
5069
7093
Infiltration .....................
6243
3609
Internal Gain ............... ...
n/a
1214.
Ducts ............................
4412
3598
Sensible Load .....................
28311
20948
Latent Load.......... ..........
n/a
5048
Minimum Zone Load
-----------
28311
-----------
25996
ZONE 'SLEEPING'
Floor Area..... 1455 sf
Volume .........I .................. 14550 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and.Solar......
13614
5613
Glazing Conduction and Solar......
3397
5712
Infiltration .....................
5478
3168
Internal Gain ....................
n/a
1076
Ducts ............................
4152
3229
Sensible Load....................
26641
18797
Latent Load ......................
n/a
4530
- Minimum Zone Load
26641
23328
iVAC SIZING HVAC Page 7
---------------------------------------------------------------------------------
?roject Title.......... Pasa Tiempo Plan:3/Casita. Date...07/16/07 14:25:17
-----------------==-------------------------=----------------------------------
MICROPAS7 v7.2.0 File-PSTMP3CR Wth=CTZ15S05 Program-HVAC SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo Plan.3/Casita
-------------------------------------------------------------------------------
GENERAL INFORMATION
Floor Area ................. 3113 sf
Volume ... ................. 32534 cf
Front Orientation.......... Front Facing 270 deg (W)
Sizing Location........*.... PALM DESERT
Latitude ................. 33.7 degrees
Winter Outside Design...... 2.6 F
Winter Inside Design....... 70 F
Summer Outside Design...... 111 F
Summer Inside Design....... 75 F
Summer Range .............. 34 F
Interior Shading Used...... Yes
Exterior Shading.Used...... Yes.
Overhang Shading Used...... Yes
Latent Load Fraction....... 0.24 .
HEATING AND COOLING LOAD SUMMARY
Heating. Cooling
Description r(Btu/hr) (Btu/hr)
Opaque Conduction and Solar...... 26201 10773
Glazing Conduction and Solar..... 8466 11625 .
Infiltration........... 11721 6777
Internal Gain........ n/a 2290
Ducts.... 8564 6526
Sensible Load .................... 54952 37992
Latent Load.... n/a .9156
Minimum Total Load 54952 47148
Note: The loads shown are only one of the criteria affecting.the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outside air,.outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin,.etc.,- must also be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
HVAC SIZING
HVAC .—Page 8
Project Title.......... Pasa Tiempo Plan 3/Casita
Date..07/16/07 14:25:17
-------------------------------------------------------------------------------
MICROPAS7 v7.20 File-PSTMP3CR Wth-CTZ15S05. .Program-HVAC
SIZING
User#-MP0864 User-D & R Calcs Run-Pasa Tiempo.
Plan 3/Casita
HEATING AND COOLING LOAD.SUMMARY
--------------------------------------
BY
ZONE
ZONE 'LIVING'
Floor Area.
1658 sf
Volume....... ..................
17984 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
12587
5341
Glazing Conduction and Solar.....
5069
6444
Infiltration .................
6243
3609
Internal Gain..... ...._...... ..
n/a
1214
Ducts .............. .*...........
4412
3444
Sensible Load... ... ...........
28311
20053
Latent Load.. ...................
. n/a
4833
Minimum Zone Load
28311
24885'
ZONE 'SLEEPING'
Floor Area....... ..............
1455 sf
Volume.. ............... ......
14550 cf
Heating
Cooling
Description
(Btu/hr)
(Btu/hr)
Opaque Conduction and Solar......
13614
5433
Glazing Conduction and Solar..:..
3397
5181
- Infiltration ...............
5478
3168
Internal Gain ....................
n/a
107.6
Ducts .............................
4152
3081
Sensible Load........ ..........
26641
17939
Latent Load ...................
n/a
4323
Minimum Zone Load
26641
22262
19
r