10-0732 (SFD) Title 24
if BUILDING ENERGY ANALYSIS REPORT PROJECT: Mr. & Mrs. Cedar 51-255 Calle Hueneme La Quinta, CA 92253 Project Designer: Coronel Enterprises 42-760 Madio Indio, Ca 92210 (760) 775-1234 Report Prepared by: ' Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 ` (760) 200-4780 U001,ca v � PQ GoNs-� Job Number: RECZ1V1FD •�'� MAR 2 5 2011 Date: BY: 2/25/2011 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. • This program developed by EnergySoft, LLC — www.energysoft.com. EnemvPro 5.1 by EnerovSoft User Number. 6712 Run Code: 2011-02-25709:19:59 ID: • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Mr. & Mrs. Cedar Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2125/2011 Project Address 51-255 Calle Hueneme La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,964 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 1,697 Radiant Barrier New Wall Wood Framed R-21 2,529 New Door Opaque Door None 20 New Slab Unheated Slab -on -Grade None 1,388 Perim = 185' New Floor Wood Framed w/Crawl Space R-19 275 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (N) 238.4 0.400 0.35 none none Bug Screen New Front (E) 44.1 0.400 0.35 none none Bug Screen New Left (S) 85.7 0.400 0.35 none none Bug Screen New Rear (IM 52.4 0.400 0.35 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Instant Gas 0 0.85 All Pipes Ins New EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-02-25709:19:59 ID: Page 3 of 21 • • 0 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project NameBuilding Mr. & Mrs. Cedar 713Multi Type m Single Family ❑ Addition Alone Family ❑ Existing+ Addition/Alteration Date 2125/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24ACB460 / 58C VX110 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnemyPro 5.1 by EnemySoft User Number.- 6712 Run Code: 2011-02-25709:19:59 ID: Page 4 of -2- 1 • • C7 PERFORMANCE CERTIFICATE:. Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Mr. & Mrs. Cedar 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 2/25/2011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 5.89 6.59 -0.70 Space Cooling 63.17 56.28 6.89 Fans 13.05 16.50 -3.46 Domestic Hot Water 15.69 9.96 5.73 Pumps 0.00 0.00 0.00 Totals 97.79 89.33 8.46 Percent Better Than Standard: 8.7% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 605 44 Fuel Available at Site: Natural Gas (S) 880 86 Raised Floor Area: 275 (tM 605 52 Slab on Grade Area: 1,388 (N) 880 238 Average Ceiling Height: 10.0 Roof 1,697 0 Fenestration Average U -Factor: 0.40 TOTAL: 421 Average SHGC: 0.35 Fenestration/CFA Ratio: 21.4% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 225/2011 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Coronel Enterprises Address 42-760 Madio Name Ish Coronel City/State/Zip Indio, Ca 92210 Phone (760) 775-1234 Signed License # Date EnemvPro 5.1 by EnemySoft User Number: 6712 Run Code: 2011-02-25709:19:59 ID: Page 5 of 21 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. & Mrs. Cedar Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1212512011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,121 0.025 R-38 0 0 New 4.2.1-A21 1st Floor Wall 337 0.069 R-21 0 90 New 4.3.1-A6 1st Floor Wall 305 0.069 R-21 90 90 New 4.3.1-A6 1st Floor Door 20 1.450 None 90 90 New 4.5.1-A1 1st Floor Wall 480 0.069 R-21 180 90 New 4.3.1-A6 1st Floor Wall 305 0.069 R-21 270 90 New 4.3.1-A6 1st Floor Slab 951 0.730 None 0 180 New 4.4.7-A1 1st Floor Slab 437 0.730 None 0 180 New 4.4.7-A1 1st Floor Roof 576 0.025 R-38 0 0 New 4.2.1-A21 2nd Floor Wall 304 0.069 R-21 0 90 New 4.3.1-A6 2nd Floor Wall 2361 0.069 R-21 90 90 New 4.3.1-A6 2nd Floor Wall 3141 0.069 R-21 180 90 New 4.3.1-A6 2nd Floor Wall 248 0.069 R-21 270 90 New 4.3.1-A6 2nd Floor Floor 275 0.037 R-19 0 180 New 4.4.1-A4 2nd Floor FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 6.2 0.400 NFRC 0.35 NFRC 0 New Double Metal Tint 1st Floor 2 Window 6.2 0.400 NFRC 0.35 NFRC 0 New Double Metal Tint 1st Floor 3 Window 20.1 0.400 NFRC 0.35 NFRC 0 New Double Metal Tint 1st Floor 4 Window 33.5 0.400 NFRC 0.35 NFRC 0 New Double Metal Tint 1st Floor 5 Window 33.5 0.400 NFRC 0.35 NFRC 0 New Double Metal Tint 1st Floor 6 Window 33.5 0.400 NFRC 0.35 NFRC 0 New Double Metal Tint 1st Floor 7 Window 21.6 0.400 NFRC 0.35 NFRC 0 New Double Metal Tint 1st Floor 8 Window 21.6 0.400 NFRC 0.35 NFRC 0 New Double Metal Tint 1st Floor 9 Window 21.6 0.400 NFRC 0.35 NFRC 0 New Double Metal Tint 1st Floor 10 Window 20.1 0.400 NFRC 0.35 NFRC 90 New Double Metal Tint 1st Floor 11 Window 2.3 0.400 NFRC 0.35 NFRC 180 New Double Metal Tint 1st Floor 12 Window 2.3 0.400 NFRC 0.35 NFRC 180 New Double Metal Tint 1st Floor 13 Window 18.1 0.400 NFRC 0.35 NFRC 180 New Double Metal Tint 1st Floor 14 Window 4.0 0.400 NFRC 0.35 NFRC 180 New Double Metal Tint 1st Floor 15 Window 4.0 0.400 NFRC 0.35 NFRC 180 New Double Metal Tint 1st Floor 16 Window 4.0 0.400 NFRC 0.35 NFRC 1 1801 New Double Metal Tint I 1st Floor (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Ri ht Fin Hot Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 JBug Screen 0.76 16 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-02-25T09:19:59 ID: Page 6 of 21 • • CERTIFICATE OF COMPLIANCE: Residential (Pant 4 of 5) CF -1 R Project Name Mr. & Mrs. Cedar Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1212512011 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 4.0 0.400 NFRC 0.35 NFRC 180 New Double Metal Tint 1st Floor 18 Window 8.0 0.400 NFRC 0.35 NFRC 180 New Double Metal Tint 1st Floor 19 Window 8.0 0.400 NFRC 0.35 NFRC 180 New Double Metal Tint 1st Floor 20 Window 8.0 0.400 NFRC 0.35 NFRC 270 New Double Metal Tint 1st Floor 21 Window 8.0 0.400 NFRC 0.35 NFRC 270 New Double Metal Tint 1st Floor 22 Window 6.0 0.400 NFRC 0.35 NFRC 270 New Double Metal Tint 1st Floor 23 Window 6.0 0.400 NFRC 0.35 NFRC 270 New Double Metal Tint 1st Floor 24 Window 6.2 0.400 NFRC 0.35 NFRC 270 New Double Metal Tint 1st Floor 25 Window 6.2 0.400 NFRC 0.35 NFRC 270 New Double Metal Tint 1st Floor 26 Window 9.8 0.400 NFRC 0.35 NFRC 0 New Double Metal Tint 2nd Floor 27 Window 9.8 0.400 NFRC 0.35 NFRC 0 New Double Metal Tint 2nd Floor 28 Window 9.8 0.400 NFRC 0.35 NFRC 0 New Double Metal Tint 2nd Floor 29 Window 5.6 0.400 NFRC 0.35 NFRC 0 New Double Metal Tint 2nd Floor 30 Window 5.6 0.400 NFRC 0.35 NFRC 0 New Double Metal Tint 2nd Floor 31 Window 8.0 0.400 NFRC 0.35 NFRC 90 New Double Metal Tint 2nd Floor 32 jWndow 8.0 0.400 NFRC 0.35 NFRC 90 New Double Metal Tint 12nd Floor (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Len H t LExt RExt Dist Left Fin Right Fin Len Hat Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 lBug Screen 0.76 32 jBug, Screen 0.76 EnergyPro 5. 1 by EnergySoft User Number. 6712 Run Code: 2011-02-25709:19:59 ID: Page 7 of 21 • • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. & Mrs. Cedar Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2125/2011 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 33 Window 8.0 0.400 NFRC 0.35 NFRC 90 New Double Metal Tint 2nd Floor 34 Window 11.0 0.400 NFRC 0.35 NFRC 180 New Double Metal Tint 2nd Floor 35 Window 4.0 0.400 NFRC 0.35 NFRC 180 New Double Metal Tint 2nd Floor 36 Window 4.0 0.400 NFRC 0.35 NFRC 180 New Double Metal Tint 2nd Floor 37 Window 6.0 0.400 NFRC 0.35 NFRC 180 New Double Metal Tint 2nd Floor 38 Window 6.0 0.400 NFRC 0.35 NFRC 180 New Double Metal Tint 2nd Floor 39 Window 6.0 0.400 NFRC 0.35 NFRC 270 New Double Metal Tint 2nd Floor 40 Window 6.0 0.400 NFRC 0.35 NFRC 270 New Double Metal Tint 2nd Floor (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC Hat Wd Ove hang Len H t I LExt RExt Dist Left Fin Right Fin Len Hat Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2011-02-25T09:19:59 ID: Page 8 of 21 • r U • CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Mr. & Mrs. Cedar Building Type © Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1212512011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built HVAC 1st Floor 1,388 13,880 2nd Floor 576 5,760 Totals 1,9641 01 0 0 HVAC SYSTEMS System Name aty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS S stem Name ki T e Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status TAKAGI T -K2 Instant Gas All Pipes Ins 175,000 0 0.85 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length (ft)c 0 i� a a — System Name Pipe Len th Pipe Diameter Insul. Thick. Qt . HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-02-25709:19:59 ID: Page 9 of 21 a MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Mr. & Mrs. Cedar Date 2/25/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent LI -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro5.1 by EnergySoft User Number: 6712 Run Code: 2011-02-25709:19:59 ID: Page 10 of 21 14 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Mr. & Mrs. Cedar 2/25/2011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d . §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 wafts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2011-02-25709:19:59 ID: Page 11 of 21 4 4 ANDATORY MEASURES SUMMARY: Residential Pa e 3 of 3 MF -1 R ect Name Date & Mrs. Cedar rr 2/25/20111 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-02-25709:19:59 ID: Page 12 of 21 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mr. & Mrs. Cedar Date 2/25/2011 System Name HVAC Floor Area 1,964 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 1,558 28,863 Return Vented Lighting 0 Return Air Ducts 1,360 Return Fan 0 Ventilation 0 0 Supply Fan 2.978 Supply Air Ducts 1,360 TOTAL SYSTEM LOAD 1 34,561 1 COIL HTG. Latent CFM 3,246 563 0 0 3,246 PEAK Heating System Sensible Output perSystem 110,000 31,112 Total Output Btuh 110,000 Output Btuh/s ft 56.0 1,188 Cooling System 0 Output perSystem 57,500 0 Total Output Btuh 57,500 -2,978 Total Output Tons 4.8 1,188 Total Output Btuh/s ft 29.3 Total Output s ft/Ton 409.9 1 30,510 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ACB460 / 58CVX110 42,739 8,344 110,000 Airflow cfm/s ft 1.02 Airflow cfm/Ton 417.4 110,000 Jan 1 AM Outside Air % 0.0% Total Adjusted System Output 42,739 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 8,344 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 69 OF 69 OF 121 OF 123 OF Heating Coil Supply Fan 2,000 cfm 122 ° F --A ROAM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 79/65°F 79/65°F 59/57°F 60/58°F c 0 c Cooling Coil Supply Fan 2.000 cfm 49.3% 61 / 58 OF :............. .... .._................... _... __.., ROOM . 78/65°F EnergyPro 5.1 by EnergySoR User Number: 6712 Run Code: 2011-02-25709:19:59 ID: Page 13 of 21 • • • ROOM LOAD SUMMARY Project Name Mr. & Mrs. Cedar System Name HVAC ROOM LOAD SUMMARY Date 2/25/2011 Floor Area 1,964 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. Zone Name Room Name Mult. CFM I Sensible Latent CFM Sensible Latent CFM Sensible 1st Floor 1st Floor 1 1,018 1 18,861 1,963 1,018 18,861 1,963 414 22,886 2nd Floor 2nd Floor 1 5401 10,003 1,283 540 10,003 1, 283 149 8,226 PAGE TOTAL TOTAL* 1,558 28,863 3,246 563 31,112 1,5581 28,8631 3,2461 563 31,112 Total includes ventilation load for zonal systems. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-02-25709:19:59 ID: Pae 14 of 21 C7 ROOM HEATING PEAK LOADS Project Name Mr. & Mrs. Cedar Date 2/25/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name 1st Floor Floor Area 1,388.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0250 X X 0.0690 X X 0.4000 X AT °F 44 = Btu/hr R-38 Roof Attic 1,121.0 1,233 R-21 Wall 1,426.9 44 = = 4,332 Double Metal Tint 313.0 44 5,509 Wood Door 20.1 X X 1.4500 X X 44 = 1,282 Slab -On -Grade perim = 185.0 0.7300 44 = = = 5,942 X X X X X X X X X X = = X X X X X X X X X X X X X X X X X X = = = = = = = X X = X X X X X X X X X X X X = = X X X X X X X X X X to another room 10.00 X 0.424 Ceiling Height ACH = = = = Page Total /60] X 44 AT Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,388 X Area 18.299 = 4,588 TOTAL HOURLY HEAT LOSS FOR ROOM 22,886 Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2011-02-25709:19:59 ID: Page 15 of 21 • ROOM HEATING PEAK LOADS Project Name Mr. & Mrs. Cedar Date 2/25/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Floor Area 576.0 ft' Indoor Dry Bulb Temperature 70 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0250 X 0.0690 X 0.4000 X 0.0370 X X X X X X X X X X X X X X X X X X X X X X X X X X X to another room 10.00 X 0.424 Ceiling Height ACH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F Btu/hr 44 = 634 44 = 3,347 44 = 1,894 44 = 448 = = Page Total 6,322 /60] X 44 = 1,904 AT R-38 Roof Attic 576.0 R-21 Wall 1,102.4 Double Metal Tint 107.6 R-19 Floor No Crawlspace 275.0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 576 X Area TOTAL HOURLY HEAT LOSS FOR ROOM 8,226 Energ Pro 5.1 by Energ Soft User Number: 6712 Run Code: 2011-02-25709:19:59 ID: Page 16 of 21 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr. & Mrs. Cedar 2/25/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name 1st Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 1,388.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Ranae: 34 OF Ot)aaue Surfaces R-38 Roof Attic R-21 Wall R-21 Wall Wood Door R-21 Wall R-21 Wall Orientation (E) I Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = 1,121.0 0.0250 56.0 337.2 0.0690 23.0 304.8 0.0690 33.0 20.1 1.4500 33.0 480.31 0.0690 26.0 304.6 0.0690 33.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration A-1 A-2 12-3 15-4 16-5 17-6 B-7 B-8 B-9 Orientation (N) (N) (N) (N) (N) (N) (N) (N) (N) Shaded Area GLF 21.0 21.0 21.0 21.0 21.0 21.0 21.0 21.0 21.0 + + + + + + + + +1 Unshaded Area 6.2 6.2 20.1 33.5 33.5 33.5 21.6 21.6 21.6 GLF X 21.0 X 21.0 X 21.0 X 21.0 X 21.0 X 21.0 X 21.0 X 21.0 XI 21.0 Page Total 0.0 X X X X 0.0 0.0 0.0 0.0 X X 0.0 0.0 X 0.0 X 0.0 X Btu/hr 1,569 694 962 862 694 5, Btu/hr 130 130 422 703 703 703 453 453 453 4,151 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.16 X 75.95 X 34 = 3,194 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18.8611 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.16 X 75.95 X 0.00276 = 1,163 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR n is RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Mr. & Mrs. Cedar - ROOM INFORMATION DESIGN CONDITIONS Room Name 1St Floor Outdoor Dry Bulb Temperature Floor Area 1,388.0 ft-- Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 78 OF Outdoor Daily Ranae: ue Surfaces Orientation Date 2/25/2011 Area U -Factor CLTD' X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fanestratinn 1-10 C-11 C-12 7-13 E-14 E-15 E-16 E-17 F-18 (Mpnitatinn Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 21.0 20.1 41.8 0.0 21.0 2.3 21.1 0.0 21.0 2.3 21.1 0.0 21.0 18.1 21.1 0.0 21.0 4.0 21.1 0.0 21.0 4.0 21.1 0.0 21.0 4.0 21.1 0.0 21.0 4.0 21.1 0.0 21.0 8.0 21.1 Page Total 112 OF 78 OF 34 OF Btu/hr 01 Btu/hr 840 48 48 381 84 84 84 84 169 1,823 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 )( 1.16 X 75.95 X 34 = 3,194 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18.861 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.16 X 75.95 X 0.00276 = 1,163 Air Sensible CFM ELA ' AW •1 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM C7 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr. & Mrs. Cedar 2/25/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name 1st Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 1,388.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr F-19 (S) 0.0 X 21.0 + 8.0 X 21.1 = 169 F-20 (1/19 0.0 X 21.0 + 8.0 X 41.8 = 334 F-21 (169 0.0 X 21.0 + 8.0 X 41.8 = 334 D-22 (K9 0.0 X 21.0 + 6.0 X 41.8 = 251 D-23 W 0.0 X 21.0 + 6.0 X 41.8 = 251 A-24 (Vii 0.0 X 21.0 + 6.2 X 41.8 = 259 A-25 (W) 0.0 X 21.0 + 6.2 X 41.8 = 259 X + X - X +1 X - Page Total 1,856 Internal Gain Btu/hr Occupants 4.0 Occupants X 2301 Btuh/occ. =1 E920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.16 X 75.95 X 34 = 3,194 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,861 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.16 X 75.95 X 0.00276 = 1,163 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,963 EnemvPro 5. 1 by EnemySoft User Number: 6712 Run Code: 2011-02-25709:19:59 ID: Pae 19 of 21 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Room Name Floor Area Indoor Dry Bulb Opaque Surfaces R-38 Roof Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-19 Floor No Crawlsoace Orientation (E) Date 2/25/2011 DESIGN CONDITIONS 2nd Floor Outdoor Dry Bulb Temperature 576.0 ft2 Outdoor Wet Bulb Temperature 78 OF Outdoor Daily Range: Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 576.0 0.0250 56.0 304.4 0.0690 23.0 236.0 0.0690 33.0 314.01 0.0690 26.0 248.0 0.0690 33.0 275.0 0.0370 19.0 0.0 21.0 5.6 21.0 0.0 21.0 8.0 41.8 0.0 21.0 8.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration H-26 H-27 H-28 G-29 G-30 J-31 J-32 J-33 K-34 Orientation (N) (N) (N) (N) (N) (E) (E) (E) (s) Shaded Unshaded 112 OF 78 OF 34 OF Btu/hr 806 483 537 563 565 1 3,1481 Area X X X X X X X X X GLF + + + + + + + + +1 Area X X X X X X X X X GLF = = = = = = = = = 0.0 21.0 9.8 21.0 0.0 21.0 9.8 21.0 0.0 21.0 9.8 21.0 0.0 21.0 5.6 21.0 0.0 21.0 5.6 21.0 0.0 21.0 8.0 41.8 0.0 21.0 8.0 41.8 0.0 21.0 8.0 41.8 0.0 1 21.0 11.01 1 21.1 Page Total Btu/hr 206 206 206 118 118 334 334 334 232 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 )( 1.16 X 31.52 X 34 = 1,326 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10.0031 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.16 X 31.52 X 0.00276 = 483 Air Sensible CFM EIA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,283 • I • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr. & Mrs. Cedar 2/25/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 576.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF, Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr E-35 (S) 0.0 X 21.0 + 4.0 X 21.1 = 84 E-36 (S) 0.0 X 21.0 + 4.0 X 21.1 c 84 L-37 (S) 0.0 X 21.0 + 6.0 X 21.1 c 126 L-38 (S) 0.0 X 21.0 + 6.0 X 21.1 c 126 D-39 (119 0.01 X 21.0 + 6.0 X 41.8 = 251 D-40 (VV) 0.0 X 21.0 + 6.0 X 41.8 = 251 X + X - X + X - X +1 X = Page Total 923 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,6001 Btu Infiltration: 1.064 X 1.16 X 31.52 X 34 = 1,326 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,003 Latent Gain Btu/hr Occupants 4 0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.16 X 31.52 X 0.00276 = 483 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,283 E,emvPro 5.1 by EnemySoft User Number. 6712 RunCode: 2011-02-25T09:19:59 ID: Page 21 of 21