08-0401 (RC) Title 24I
TITLE 24 REPORT
Title 4 Re ofpr:
The Dunes etail en er - Retail 3
79-710 Highway 111 #J05'
La Quinta, CA 92253
C?a•Cc-� �d � �� �D5
Project Designer:
KKE Architects
525 East Colorado Boulevard
Pasadena, CA 91101
(626) 796-8230
Report Prepared By:
C+J Technical Solutions
C&J Technical Solutions And Services, Inc.
4000 Valley Blvd., Suite 103
Walnut, CA 91789
(909) 598-6067
Job Number:
C07079
MAR 0 3 2008
Date:
BY
2/28/2008
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.4 by EnergySoft Job Number: C07079 User Number: 5950
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Nonresidential Performance Title 24 Forms 3
Form ENV -MM Envelope Mandatory Measures 14
Form MECH-MM Mechanical Mandatory Measures 15
HVAC System Heating and Cooling Loads Summary 17
EnergyPro 4.4 by EnergySoft Job Number: C07079 User Number: 5950
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1
PROJECT NAME
This Certificate of Compliance Ilsts the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
DATE
The Dunes Retail Center - Retail 3
BUILDING CONDITIONED FLOOR AREA
10,008 Sq,Ft.
2/28/2008
PROJECT ADDRESS
NONRESIDENTIAL HIGH RISE RESIDENTIAL 0
HOTEL/MOTEL GUEST ROOM
79-710 Highway 111 La Quinta
NEW CONSTRUCTION ADDITION ❑
EXISTING + ADDITION/ALTERATION
Building Permit #
PRINCIPAL DESIGNER - ENVELOPE
TELEPHONE
California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect.
KKE Architects
(626) 796-8230
contractor performing this work.
DOCUMENTATION AUTHOR
TELEPHONE
1
Checked by/Date
C&J Technical Solutions And Services, Inc.
(909) 598-6067
Enforcement Agency Use
GENERAL INFORMATION
This Certificate of Compliance Ilsts the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations. This certificate applies only to a Building using the performance compliance approach.
DATE OF PLANS
BUILDING CONDITIONED FLOOR AREA
10,008 Sq,Ft.
CLIMATE ZONE
15
BUILDING TYPE ®
NONRESIDENTIAL HIGH RISE RESIDENTIAL 0
HOTEL/MOTEL GUEST ROOM
PHASE OF CONSTRUCTION ®
NEW CONSTRUCTION ADDITION ❑
EXISTING + ADDITION/ALTERATION
STATEMENT OF COMPLIANCE
This Certificate of Compliance Ilsts the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations. This certificate applies only to a Building using the performance compliance approach.
The documentation preparer hereby certifies that the documentation Is ac urate and complete.
DOCUMENTATION AUTHOR
SIGNATU DAT
C+J Technical Solutions
he Principal Designer hereby certifys that the proposed building de gn represe d ' t 's t of construction do u ents is
consistent with the other compliance forms and worksheets, with t specificati s nd w h any other calculations bmitted With this
permit application. The proposed building as designed meets the ergy effici n rements contained in sec tns 110, 6,
through 118, and 140, 142, 143 or 149 of Title 24, Part 6.
ENV. LTG. MECH.
R ❑ ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to
sign this document as the person responsible for its preparation; and that I am licensed in the State of
California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect.
0 ❑ 2.1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section
5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed
contractor performing this work.
R R ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document
because it pertains to a structure or type of work described as exempt pursuant to Business and Professions
Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in
full in the Nonresidential Manual.)
ENVELOPE COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
ENV -1
Required Forms
PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATURE LIC. NO. DATE
KKE Architects
LIGHTING COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
Lighting Compliance Not In The Scope Of
Required Forms
This UUMILLdl
PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE
MECHANICAL COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
MECH-1 MECH-2 MECH-3 MECH-5
Required Forms
PRINCIPAL MECHANICAL DESIGNER - NAME Si UR
LIC. NO.
DA
Polar Barr Air Conditioning Inc.
IS1911&)'j
I EneravPro 4.4 by EneravSoft User Number: 5950 Job Number: C07079 Paae:3 of 24 1
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF -
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
ANNUAL TDV ENERGY USE SUMMARY (kBtu/sgft-yr)
ENERGY COMPONENT
Standard
Design
1
. Proposed
Design
8
Compliance
Margin
Space Heating' .
Space Cooling
Indoor Fans
Heat Rejection
Pumps & Misc.
Domestic Hot Water
Lighting
Receptacle
Process
TOTALS:
Percent better than Standard:
0.88
0.66
0.22
343.56
260.78
82.77
54.82
60.08
-5.26
o.o0
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
172.79
172.79
0.00
91.58
91.58
0.00
o.o0
0.00
0.00
663.63
585.90
77.73
1,316
11.7%°
( 11.7% eXCIL
BUILDING COMPL
r GENERAL INFORMATION
Building Orientation
Number of Stories
Number of Systems
Number of. Zones
N o deg
Conditioned Floor Area 10,008 sgft.
Unconditioned Floor Area 0 sgft.
Conditioned Footprint Area 10,008 sgft.
Fuel Type Natural Gas
1
10
8
950
Orientation Gross Area Glazing Area Glazing Ratio
Front Elevation
N)
950
sgft.•
427
sgft.
44.9%
.'
Left Elevation
(E)
-
1,700
sgft.
107
sgft.
6.30
Rear Elevation
S
600
sgft.
250
sgft.
41.6%
Right Elevation
Total
Roof
(W)
2,235 sgft.
5,485 sgft.
10,008 sgft.
1,316
sgft.
sgft.
sgft.
58.99/6
2,100
=:�
Standard Proposed
Lighting Power Density 1.616 wisgft. 1.616 wisgn.
Prescriptive Env. Heat Loss 1,687 etum 1,787 stun,
Prescriptive Env. Heat Gain 183,942 etum-F 220,179 Btum-F
Remarks:
Run Initiation Time: 02/28/08 16:35:09 Run Code: 1204245309
EnergyPro 4.4 by EnergySoft User Number: 5950 1Job Number: C07079 Page:4 of 24
PERFORMANCE CERTIFICATE OF COMPLIANCE Part of PERF -1
PROJECT NAME
The Dunes Retail Center - Retail 3
DATE
2/28/2008
ZONE INFORMATION
System Name
Zone Name
Occupancy Type
Floor
Area
(sgft.)
Inst.
LPD
(W/sf)l
Ctrl. Allowed LPD Proc.
Credits Area Tailored Loads
(W/sf)2 /sf 3 /sf 4 (W/sf)
Tenant A
Zone 1
Retail Sales, Wholesale
1,308
-1.700
Tenant B
Zone 1
Retail Sales, Wholesale
1,200
-1.700
Tenant C
Zonal
Retail Sales, Wholesale
1,200
-1.700
Tenant D
Zonal
Retail Sales, Wholesale
1,200
-1.700
Tenant E
Zone 1
Retail Sales, Wholesale
1,200
-1.700
Tenant F .-
Zone 1
Barber and Beauty Shop
1,200
-1.000
Tenant G
Zonell
Retail Sales, Wholesale
1,200
-1.700
Tenant H
Zonell
Retail Sales Wholesale
1,500
"1.700
Notes: 1. See LTG -2-C
(Items marked with asterisk, see LTG -2 -C by others)
2. See LTG -4-C 3. See LTG -5-C
(by others)
4. See LTG -6-C
Items above require special documentation
EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST
The local enforcement agency should pay special attention to the Items specitiea In tins cnecKus[. i nese items require speciai written fusuncazion
and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of
the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation
submitted.
The HVAC System "York BHP060" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement.
The HVAC System "York BHP042" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement.
The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and
documentation for their use have been provided by the applicant.
Authorized Signature or Stam
I EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Page:5 of 24 1
CERTIFICATE OF COMPLIANCE ENV -7-C
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
OPAQUE SURFACES
# Surface
Type
Area
U -Fac.
Insulation
Cay. Cont.
Act.
Am.
Tilt
Cond:
Status
Joint Appendix
IV Reference
Location / Comments
1 Wall
461
0.074
R-19
R-0.0
0
90
New
09-A5
Zonell
2 Wall
250
0.074
R-19
R-0.0
90
90
New
09-A5
Zone 1
3 Wall
347
0.074
R-19
R-0.0
270
90
New
09-A5
Zone 1
4 Roof
1,308
0.036
R-30
R-0.0
0
0
New
02-A9
Zonell
5 lWall
1 200
0.074
R-19
R-0.01
90
90
1 New
09-A5
Zonell
6 Wall
12
0.074
R-19
R-0.0
270
90
New
09-A5
Zone 1
7 Roof
1,200
0.036
R-30
R-0.0
0
0
New
02-A9
Zonell
8 Wall
200
0.074
R-19
R-0.0
90
90
New
09-A5
Zone 1
9 Wall
12
0.074
R-19
R-0.0
270
90
New
09-A5
Zone 1
10 Roof
1,200
0.036
R-30
R-0.0
0
0
New
02-A9
Zone'l
11 Wall
200
0.074
R-19
R-0.0
90
90
New
09-A5
Zone 1
12 Wall
1 512
0.074
R-19
R-0.0
270
90
New
09-A5
Zonell
13 Roof
1,200
0.036
R-30
R-0.0
0
0
New
02-A9
Zone 1
14 Wall
200
0.074
R-19
R-0.0
90
90
New
09-A5
Zonell
15 Wall
12
0.074
R-19
R-0.0
270
90
New
09-A5
Zone 1
16 Roof
1,200
0.036
R-30
R-0.0
0
0
New
02-A9
Zone 1
17 Wall
200
0.074
R-19
R-0.0
90
90
New
09-A5
lZonel
18 Wall
1
0.074
R-19
R-0.0
270
90
New
09-A5
jZonel
19 lRoof
1 1,2001
0.036
R-30
R-0.01
0
0
New
02-A9
jZonel
20 lWall
1 2001
0.074
R-1 91
8-0.0
90
90
New
09-A5
IZonel
Removed)
1-1 More than or equal to 10,000 sq.tt. of site-bullt fenestration area must Include a label certificate either Issued by NFRC or provide a CEC Default Label Certificate using the default LI -factors from
Standards Table 116-A and B. Certificate shall be filed In the contractor's omlect office during construction and In the building managers office atter construction
#
ITYpe
Area U -Fac?
SHGC2
Act.
Azm.
Cond.
Stat.
Glazing Type
Location/
Comments
1
Window
Front
N
75 0.560 NFRC
0.41 NFRC
0
New
SOLARBAN 60 LOW -E
Zone 1
2
Window
Front
N
140 0.560 NFRC
0.41 NFRC
0
New
SOLARBAN 60 LOW -E
Zone 1
3
Window
Front
N
24 0.560 NFRC
0.41 NFRC
0
New
SOLARBAN 60 LOW -E
Zone 1
4
Window
Right
W
48 0.560 NFRC
0.41 NFRC
270
New
SOLARBAN 60 LOW -E
Zone 1
5
Window
Right
W
140 0.560 NFRC
0.41 NFRC
2701
New
SOLARBAN 60 LOW -E
Zone 1
6
Window
Right
(W)
140 0.560 NFRC
0.41, NFRC
270
New
SOLARBAN 60 LOW -E
Zone 1
7
Window
Right
W
48 0.560INFRCI
0.41 NFRC
270
New
SOLARBAN 60 LOW -E
Zone 1
8
Window
Right
W
140 0.560 NFRC
0.41 NFRC
270
New
SOLARBAN 60 LOW -E
Zone 1
9
Window
Right
W
48 0.560 NFRC
0.41 NFRC
270
New
SOLARBAN 60 LOW -E
Zone 1
10 Window
Right
(W)
140 0.560 NFRC
0.41 NFRC
270
New
SOLARBAN 60 LOW -E
Zone 1
11 Window
Right
W)
48 0.560 NFRC
0.41 NFRC
270
New
SOLARBAN 60 LOW -E
Zone 1
12 Window
Right
W
140 0.560 NFRC
0.41 NFRC
270
New
SOLARBAN 60 LOW -E
Zone 1
13 lWindow
Right
W
48 0.560 NFRC
0.41 INFRCI
2701
New
I SOLARBAN 60 LOW -E
Zone 1
(1) U -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value.
2 SHGC Type: 116.8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR SHADING
##
Exterior Shade Type
SHGC
Window
Hgt. Wd.
Overhang Left Fin Right Fin
Len. H t. LExt.RExt. Dist. Len. Hat. Dist. Len. H t.
1
None
0.76
10.0 7.0
4.0
0.1
4.0
4.0
2
None
0.76
3
None
0.76
7.0 3.0
4.0
0.1
4.0
4.0
4
None
0.76
7.0 3.0
4.0
0.1
4.0
4.0
5
None
0.76
6
None
0.76
8.0 13.3
4.0
0.1
4.0
4.0
7
None
0.76
7.0 3.0
4.0
0.1
4.0
4.0
8
None
0.76
9
None
0.76
8.0 3.0
4.0
0.1
4.0
4.0
10
None
0.76
10.5 7.0
3.0
0.1
3.0
3.0
11
None
0.76
8.0 3.0
1 3.0
0.1
3.0
3.0
12
None
0.76
13
None
0.76
8.0 3.0
1 4.0
0.1
4.0
4.0
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
1-1The proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 W, a ceiling height greater than 15 feet, and an LPD for general
lighting of at least 0.5 W/ft2. See Section 143(c). If this box Is checked, ENV -4-C must be filled out. when submitting under the Prescriptive Compliance Approach.
1 EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Paae:6 of 24 1
CERTIFICATE OF COMPLIANCE ENV -1-C
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
OPAQUE SURFACES
# Surface
Type
Area
U -Fac.
Insulation
Cay. Cont.
Act.
Am.
Tilt
Cond:
I Status
Joint Appendix
IV Reference
Location / Comments
21 Wall
12
0.074
R-19
R-0.0
270
90
1 New
09-A5
Zone 1
22 Roof
1,20
0.036
R-30
R-0.0
0
0
New
02-A9
Zone 1
23 Wall
62
0.074
R-19
R-0.0
0
90
New
09-A5
Zone 1
24 Wall
350
0.074
R-19
R-0.0
180
90
New
09-A5
Zone 1
25 Wall 1
143
0.074
R-19
R-0.0
90
90
New
09-A5
Zone 1
26 Roof
1,500
0.036
R-30
R-0.0
0
0
New
02-A9
Zone 1
New
SOLARBAN 60 LOW -E
Zone 1
21 Window
Rear
S
94 0.560 NFRC
0.41 NFRC
180
New
SOLARBAN 60 LOW -E
Zone 1
22 Window
Rear
S
107 0.560 NFRC
0.41 NFRC
180
New
SOLARBAN 60 LOW -E
Zone 1
23 Window
Left
(E)
107 0.560 NFRC
0.41 NFRC
90
New
SOLARBAN 60 LOW -E
Zone 1
F-1 More than or equal to 10,000 sq.lt. of she-bulft fenestration area must Include a label certificate either Issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from
Standards Table 116-A and B. Cert0lcate shall be filed In the contractor's orolect office during construction and In the building managers office after construction
# 1 Type
Area U -Fac'
SHGC2
Act.
Azm.
Cond.
Stat.
Glazing Type
Location/
Comments
14 Window
Ri ht
W
48 0.560 NFRC
0.41 NFRC
270
New
SOLARBAN 60 LOW -E
Zone 1
15 Window
Right
W
140 0.560 NFRC
0.41 NFRC
270
New
SOLARBAN 60 LOW -E
Zone 1
16 Window
Right
W
140 0.560 NFRC
0.41 NFRC
270
New
SOLARBAN 60 LOW -E
Zone 1
17 Window
Right
W
48 0.560 NFRC
0.41 NFRC
270
New
SOLARBAN 60 LOW -E
Zone 1
18 Window
Front
N
140 0.560 NFRC
0.41 NFRC
01
New
SOLARBAN 60 LOW -E
Zone 1
19 Window
Front
(N)
48 0.560 NFRC
0.41 NFRC
0
New
SOLARBAN 60 LOW -E
Zone 1
20 lWindow
Rear
S
48 0.560 NFRCI
0.41 NFRC
180
New
SOLARBAN 60 LOW -E
Zone 1
21 Window
Rear
S
94 0.560 NFRC
0.41 NFRC
180
New
SOLARBAN 60 LOW -E
Zone 1
22 Window
Rear
S
107 0.560 NFRC
0.41 NFRC
180
New
SOLARBAN 60 LOW -E
Zone 1
23 Window
Left
(E)
107 0.560 NFRC
0.41 NFRC
90
New
SOLARBAN 60 LOW -E
Zone 1
(1) 1.1 -factor Type: 11 6-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value.
2 SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR SHADING.
## Exterior Shade Type
SHGC
Window
Hgt. Wd.
Overhang Left Fin Right Fin
Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t.
14 None
0.76
8.0 3.0
4.0 0.1
4.0
4.0
15 None
0.76
16 None
0.76
17 None
0.76
7.0 3.0
4.0 0.1
4.0
4.0
18 None
0.76
8.0 13.3
4.0 0.1
4.0
4.0
19 None
0.76
8.0 3.0
4.0 0.1
4.0
4.0
20 None
0.76
8.0 3.0
4.0 0.1
4.0
4.0
21 None
0.76
10.0 9.0
2.0 0.1
2.0
2.0
22 None
0.76
8.0 10.0
4.0 0.1
4.0
4.0
23 None
0.76
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
The proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 ft2, a telling height greeter than 15 feet, end an LPD for general
lighting of at least 0.5 W1112. See Section 143(x). If this box Is checked, ENV -4-C must be filled out. when submitting under the Prescriptive Compliance Approach.
EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Paoe:7 of 24 1
(CERTIFICATE OF COMPLIANCE MECH-I-C
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 1
2/28/2008
ueslgner:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to
check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the
equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential
ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent
selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work
appropriately.
Building Departments:
SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or�space, or a new space -conditioning system serving a
building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for
Code Compliance.
In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation
certificates. and ooeratina and maintenance information meet the recuirements of Section 10-103(b) and Title 24 Part 6.
STATEMENT OF COMPLIANCE
❑ MECH-2-A: Ventilation System Acceptance Document
-Variable Air Volume Systems Outdoor Air Acceptance
-Constant Air Volume Systems Outdoor Air Acceptance
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit.
❑ MECH-3-A: Packaged HVAC Systems Acceptance Document
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit.
❑ MECH-4-A: Air -Side Economizer Acceptance Document
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the
commission do not require equipment testing but do require construction Inspection.
❑ MECH-5-A: Air Distribution Acceptance Document
Equipment requiring acceptance testing
This test required If the unit serves 5,000112 ofspaca or less and 25% or more of the ducts are In nonconoitioned or somiconditloned space (Ore an
attic. New systems that most the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or
replace the packaged unit.
❑ MECH-6-A: Demand Control Ventilation Acceptance Document
Equipment requiring acceptance testing
All new DCV controls Installed on new or existing packaged systems must be tested.
❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document
Equipment requiring acceptance testing
All new VA fan volume controls installed on new or existing systems must be tested
❑ MECH-8-A:-Hydronic System Control Acceptance Document
-Variable Flow Controls Applies to chilled and hot water systems.
-Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header.
-Supply Water Temperature Reset Controls
Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 SWIM
-Water-loop Heat Pump Controls
Applies to all new watedoop heat pump systems where the combined loop pumps are greater than 5 hp.
-Variable Frequency Controls Applies to all now distribution pumps onnow variable flow chilled hydrant: heat pump
or condenser water systems where the pumps motors are greater than 5 hp.
Equipment re uiring acceptance testing
EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Page:8 of 24
AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
SYSTEM FEATURES
ITEM OR SYSTEM TAG(S)
Number of Systems
T-24
MANDATORY MEASURES Section
Heating Equipment Efficiency
Cooling Equipment Efficiency
Heat Pump Thermostat
Furnace Controls
Natural Ventilation
Minimum Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control
Outdoor Damper Control
Isolation Zones
Pipe Insulation
Duct Insulation
PRESCRIPTIVE MEASURES
Calculated Heating Capacity x 1.43 2
Proposed Heating Capacity 2
Calculated Sensible Cooling Capacity x 1.212
Proposed Sensible Cooling Capacity 2
Fan Control
DP Sensor Location
Supply Pressure Reset (DDC only)
Simultaneous Heat/Cool
Economizer
Heating Air Supply Reset
Cooling Air Supply Reset
Duct Sealing for Prescriptive Compliance
AIR SYSTEMS, Central or Single one
Tenant A
Tenant B
Tenant C
2
1
1
Reference on Plans or Specification 1
112(a)
7.70 HSPF
7.70 HSPF
7.70 HSPF
112(a)
13.0 SEER / 11.3 EER
13.0 SEER / 11.2 EER
13.0 SEER / 11.2 EER
112(b)
Yes
Yes
Yes
112(c), 115(a)
n/a
n/a
n/a
121(b)
No
No
No
121 b
327 cfm
300 cfm
300 cfm
121 c
No
No
No
121(c)
No
No
No
121 c 122(e)
Programmable Switch
Programmable Switch
Pro rammable Switch
122(e)
Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required
122
Gravity
Gravity
Gravity
122(g)
n/a
n/a
n/a
123
No
124
R-4.2 I
R-4.2 I
R-4.2
144 a & b
n/a
n/a
n/a
144 ja & b
52,464 btuh
34,976 btuh
34,976 btuh
144 a & b
n/a
n/a
n/a
144 a & b
61,854 btuh
44,043 btuh
46,431 btuh
144 c
Constant Volume
Constant Volume
Constant Volume
144 (c)
144 c
No
No
No
144 d
No
No
No
144 a
No Economizer
No Economizer
No Economizer
144
Constant Temp
Constant Ternp
Constant Tem
144(f)
Constant Temp
Constant Temp
Constant Temp
144 k
No
No
No
1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the
required features are documented. If a requirement is not applicable, put "N/A" in the column.
2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1.
3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing Is required for Prescriptive Compliance,
see PERF -1 for performance method duct sealing requirements.
I Faun Inniayon I lme: 02/2S/OS 16:35:09 Hun Gocfe: 1204245309 1
EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Page:9 of 24
AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
SYSTEM FEATURES
ITEM OR SYSTEM TAG(S)
Number of Systems
T-24
MANDATORY MEASURES Section
Heating Equipment Efficiency
Cooling Equipment Efficiency
Heat Pump Thermostat
Furnace Controls
Natural Ventilation
Minimum Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control
Outdoor Damper Control
Isolation Zones
Pipe Insulation
Duct Insulation
PRESCRIPTIVE MEASURES
Calculated Heating Capacity x 1.43 2
Proposed Heating Capacity 2
Calculated Sensible Cooling Capacity x 1.212
Proposed Sensible Cooling Capacity 2
Fan Control
DP Sensor Location
Supply Pressure Reset (DDC only)
Simultaneous Heat/Cool
Economizer
Heating Air Supply Reset
Cooling Air Supply Reset
Duct Sealing for Prescriptive Compliance
1: For each central and single zone air systems (or group of similar units) fill In the reference to sheet number and/or specification section and paragraph number where the
required features are documented. If a requirement is not applicable, put "N/A" in the column.
2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1.
3: Enter Yes If System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing Is required for Prescriptive Compliance,
see PERF -1 for performance method duct sealing requirements.
NATFA TO FIFI n - Fnr Rrrilrlinn npnnrtmpnt Ilcp nniv
AIR SYSTEMS, Central or Single one
Tenant D
Tenant E
Tenant F
1
1
1
Reference on Plans or Specification 1
112(a)
7.70 HSPF
7.70 HSPF
7.70 HSPF
112(a)
13.0 SEER / 11.2 EER
13.0 SEER / 11.2 EER
13.0 SEER / 11.2 EER
112(b)
Yes
Yes
Yes
112(c), 115(a).
n/a
n/a
n/a
121(b)
No
No
No
121(b)
300 cfm
300 cfm
480 cfm
121 c
No
No
No
121(c)
No
No
No
121 c 122 a
Pro rammable Switch
Programmable Switch
Procirammable Switch
122(e)
Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required
122
Gravity
Gravity
Constant Temp
122(g)
n/a
--Gravity
n/a
n/a
123
No
124 1
R-4.2
I R-4.2 I
R-4.2
144 a & b
n/a
n/a
n/a
144 a & b
34,976 btuh
34,976 btuh
34,976 btuh
144 a & b
n/a
n/a
n/a
144 a & b
46,458 btuh
46,431 btuh
49,525 btuh
144 c
Constant Volume
Constant Volume
Constant Volume
144 (c)
144 c
No
No
No
144 d
No
No
No
144(s)
No Economizer
No Economizer
No Economizer
144
Constant Temp
Constant Temp
Constant Tem
144 (f)
Constant Temp
Constant Temp
Constant Temp
F144 (k)
No
No
No
Run Initiation Time: 02/28/08 16:35:09 Run Code: 1204245309
EnergyPro 4.4 by EnergvSoft User Number: 5950 Job Number: C07079 Page:10 of 24
AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
SYSTEM FEATURES
ITEM OR SYSTEM TAG(S)
Number of Systems
T-24
MANDATORY MEASURES Section
Heating Equipment Efficiency
Cooling Equipment Efficiency
Heat Pump Thermostat
Furnace Controls
Natural Ventilation
Minimum Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control
Outdoor Damper Control
Isolation Zones
Pipe Insulation
Duct Insulation
PRESCRIPTIVE MEASURES
Calculated Heating Capacity x 1.43 2
Proposed Heating Capacity 2
Calculated Sensible Cooling Capacity x 1.212
Proposed Sensible Cooling Capacity 2
Fan Control
DP Sensor Location
Supply Pressure Reset (DDC only)
Simultaneous HeaVCool
Economizer
Heating Air Supply Reset
Cooling Air Supply Reset
Duct Sealing for Prescriptive Compliance
AIR SYSTEMS, Central or Single Zone
Tenant G Tenant H
1 2
Reference on Plans or Specification t
112(a)
7.70 HSPF
7.70 HSPF
144 a & b
112(a)
13.0 SEER / 11.2 EER
13.0 SEER / 11.3 EER
n/a
112(b)
Yes
Yes
64,374 btuh
112(c), 115(a)
n/a
n/a
144 (c
121(b)
No
No
No
121(b)
300 cfm
375 cfm
No
121 c
No
No
144
121(c)
No
No
Constant Temp
121(c), 122(e)
Programmable Switch
Programmable Switch
No
122(e)
Heating & Cooling Required
Heating & Cooling Require
122
Gravity
Gravity
122(g)
n/a
n/a
123
124
R-4.2
R-4.2
144 a & b
n/a
n/a
144 a & b
34,976 btuh
52,464 btuh
144 a & b
n/a
n/a
144 a & b
46,429 btuh
64,374 btuh
144 c
Constant Volume
Constant Volume
144 (c
144 c
No
No
144 d
No
No
144 a
No Economizer
No Economizer
144
Constant Temp
Constant Tem
144 (f)
Constant Temp
Constant Temp
144 k)
No
No
1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the
required features are documented. If a requirement is not applicable, put "N/A" in the column.
2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1.
3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance,
see PERF -1 for performance method duct sealing requirements.
I Hun Initiation Time: u2/2S/u8 16:35:09 Run Code: 1204245309 1
EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Paoe:11 of 24 1
MECHANICAL VENTILATION MECH-3-CI
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
PRESCRIPTIVE REHEAT
TLIMITATION (Section 144(d))
MECHANICAL VENTILATION Section
121(b)2)
AREA
BASIS
OCCUPANCY
BASIS
VAV MINIMUM
A
B
C
D
E
F
G
H I
I
J
K
L
M
N
ZONE/SYSTEM
0
n3
a
vim—
°
a
`W'0
-n
T�3
c
�-5.Cr 3
xD
C)M
..y�
Z
C3
cQ
�cD
coy
Man
T
°'�
'
�
m�
x°
-nC-A
"��
�
ado
ox
o �
��D
�
n;m
-A .m
�Dfo
�'
ca
��
cpm°
nu)
� -
9N
n
�°°
rn x
.0
�a
o°
a3d
o°x
Oyo
0_
o
N
='Q
a
09
-.
m
'
w
n
Zone 1
1,308
0.25
327
327
327
Tenant A
Total
327
327
Zone 1
1,20C
0.25
300
300
300
Tenant B
Total
300
300
Zone 1
1,200
0.25
300
300
300
Tenant C
Total
300
3001
1
Zone 1
1,200
0.25
300
300
300
Tenant D
Total
300
300
Zone 1
1,200
0.25
300
300
300
Tenant E
Total
300
300
Zone 1
1,200
0.40
4801
1 480
480
Tenant F r' ! s
Total
480
480
Zone 1
1,200
0.25
300
1
300
300
Tenant G
Total
300
300
Zone 1
1.50C
0.25
375
375
375
Tenant H
Total
1 375
3751
1
C Minimum ventilation rate per Section 121 Table 121-A
E Based on fi seat or the greater of the expected number of occupants and 50% of the CBC occupant load foregress purposes fors aces without fixed seating.
H Required Ventilation Air (REO'D V.A.) is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS (column D or G).
I Must be greater than orequal to H or use Transfer Alr column N to make up the difference.
J Design fan supply cfm (Fan CFM) x 30%; or
K Condition area (ft. sq.) x 04 cfm/ft. sq.; or
L Maximum of Columns H, J, K, or 300 cfm
M IThIs must be less than orequal to Column L and greater that orequal to the sum of Columns H + N.
N Transfer air must be provided where the Required Ventilation Air (column 1) Is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal
to the difference between the Required Ventilation Air (column 1) and the Design Minimum Air (column M), column H - M.
EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Page: 12 of 24
MECHANICAL EQUIPMENT DETAILS
Part 1 of 2 MECH-5-C
PROJECT NAME
The Dunes Retail Center - Retail 3
COOLING
DATE
2/28/2008
CHILLER AND TOWER SUMMARY
System Type
QN
Efficiency
Tons
PUMPS
Output
Equipment Name
Equipment Type
Economizer Type
Tot.
City
GPM
BHP
Motor Drive
Eff. Eff.
Pump
Control
7.70 HSPF
-.City.
13.0 SEER/ 11.3 EER
New
No Economizer
York BHP060
Packaged DX
6
56,000
0.0
7.70 HSPF
55,000
13.0 SEER / 11.2 EER
New
No Economizer
DHW BOILER SUMMARY
Energy Standby TANK INSUL.
Rated Vol. Condition Factor Loss or Ext.
Svstem Name Svstem Tvoe Distribution Tvoe atv InDut (Gals.) I Status i or RE Pilot I R -Val.
CENTRAL SYSTEM RATINGS
HEATING
COOLING
System Name
System Type
QN
Output
Aux.
kW
Eff.
Output
EfflclencV
Condition
Status
Economizer Type
York BHP042
Packaged DX
4
42,000
0.0
7.70 HSPF
42,000
13.0 SEER/ 11.3 EER
New
No Economizer
York BHP060
Packaged DX
6
56,000
0.0
7.70 HSPF
55,000
13.0 SEER / 11.2 EER
New
No Economizer
ENVELOPE MANDATORY MEASURES ENV -MM
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 1
2/28/2008
DESCRIPTION
Designer
Enforcement
X] §118(a) Installed Insulating Material shall have been certified by the manufacturer to
comply with the California Quality Standards for Insulating material, Title 20,
Chapter 4, Article 3.
R§118(c) All Insulating Materials shall be Installed in compliance with the flame spread rating
and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2.
X❑ §117(a) All Exterior Joints and openings in the building that are observable sources of air
leakage shall be caulked, gasketed, weatherstripped or otherwise sealed.
X❑ §116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit
and the building, and shall be weatherstripped (except for unframed glass doors
and fire doors).
F-] § 116(a)1 Manufactured Doors and Windows Installed shall have air Infiltration rates not
exceeding those shown in Table Number 1-E. of the Standards. Manufactured
fenestration products must be labeled for U -value according to NFRC procedures.
§118(e) Demising Walls in Nonresidential Buildings:
The opaque portions of framed demising walls In nonresidential buildings shall
have Insulation with an Installed R -value of no less than R-13 between framing
members.
EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Page:14 of 24
MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
DESCRIPTION
Designer
Enforcement
Equipment and Systems Efficiencies
0 ' § 11 Any appliance for which there is a California standard established In the
.Appliance Efficiency Regulations will comply with the applicable standard.
a §115(a) Fan type central furnaces shall not have a pilot light.
§123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees
Fahrenheit, or within HVAC equipment, shall be insulated in accordance with
Standards Section 123.
X❑ §124 Air handling duct systems shall be Installed and Insulated In compliance with
Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards.
Controls
§122(e) Each space conditioning system shall be Installed with one of the following:
X] §122(e)1 A Each space conditioning system serving building types such as offices and
manufacturing facilities (and all others not explicitly exempt from the
requirements of Section 112 (d)) shall be Installed with an automatic time switch
with an accessible manual override that allows operation of the system during
off -hours for up to 4 hours. The time switch shall be capable of programming
different schedules for weekdays and weekends and have program backup
capabilities that prevent the loss of the device's program and time setting for at
least 10 hours if power Is Interrupted; or
§122(e)1 B An occupancy sensor to control the operating period of the system; or
❑ §122(e)1 C A41 -hour timer that can be manually operated to control the operating period of
the system.
0 §122(e)2 Each space conditioning system shall be installed with controls that temporarily
restart and temporarily operate the system as required to maintain a setback
heating and/or a setup cooling thermostat setpoint.
§122(g) Each space conditioning system serving multiple zones with a combined
conditioned floor area more than 25,000 square feet shall be provided with
Isolation zones. Each zone: shall not exceed 25,000 square feet; shall be
provided with isolation devices, such as valves or dampers, that allow the supply
of heating or cooling to be setback or shut off Independently of other Isolation
areas; and shall be controlled by a time control device as described above.
❑ §122(a&b) Each space conditioning system shall be controlled by an Individual thermostat
that responds to temperature within the zone. Where used to control heating, the
control shall be adjustable down to 55 degrees F or lower. For cooling, the
control shall be adjustable up to 85 degrees F or higher. Where used for both
heating and cooling, the control shall be capable of providing a deadband of at
least 5 degrees F within which the supply of heating and cooling Is shut off or
reduced to a minimum.
RI §122(c) Thermostats shall have numeric setpoints In degrees Fahrenheit (F) and
adjustable setpoint stops accessible only to authorized personnel.
§112(b) Heat pumps shall be Installed with controls to prevent electric resistance
supplementary heater operation when the heating load can be met by the heat
pump alone.
EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Pagel5 of 24
MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 1
2/28/2008
Description
Designer
Enforcement
Ventilation
❑X §121(e) Controls shall be provided to allow outside air dampers or devices to be operated
at the ventilation rates as specified on these plans.
❑ §122(f) Gravity or automatic dampers Interlocked and closed on fan shutdown shall be
provided on the outside air intakes and discharges of all space conditioning and
exhaust systems.
§122(f) All gravity ventilating systems shall be provided with automatic or readily
accessible manually operated dampers in all openings to the outside, except for
combustion air openings.
§121 (f)i Air Balancing: The system shall be balanced In accordance with the National
Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or
Associated Air Balance Council (AABC) National Standards (1989); or
§121(f)2 Outside Air Certification: The system shall provide the minimum outside air as
shown on the mechanical drawings, and shall be measured and certified by the
Installing licensed C-20 mechanical contractor and certified by (1) the design
mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3)
the person with overall responsibility for the design of the ventilation system; or
❑ §121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or
remote device capable of measuring the quantity of outside air on a continuous
basis and displaying that quantity on a readily accessible display divice; or
§121(f)4 Another method approved by the Commission.
Service Water Heating Systems
❑ §113(b)2 If a circulating hot water system Is Installed, it shall have a control capable of
automatically turning off the circulating pump(s) when hot water Is not required.
❑ §113(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit
the outlet temperature to 110 degrees F.
EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Pagel6 of 24
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
SYSTEM NAME FLOOR AREA
Tenant A 1,308
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems
2
Heating System
Output per System
42,000
Total Output (Btuh)
84,000
Output (Btuh/sqft)
64.2
Cooling System
Output per System
42,000
Total Output (Btuh)
84,000
Total Output (Tons)
7.0
Total Output (Btuh/sqft)
64.2
Total Output (sgft/Ton)
186.9
Air System
CFM per System
1,400
Airflow (cfm)
2,800
Airflow (cfm/sqft)
2.14
Airflow (cfm/Ton)
400.0
Outside Air (%)
11.7
Outside Air (cfm/sqft)
0.25
Note: values above
HEATING SYSTE
26.0 OF
Outside Air
327 cfm
69.7 of
11.0 / 77.6 of
Outside Air
327 cfm
74.7/61.8 ° F
at ARI conditions
YCHROMETRICS
64.60F
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensible
Latent
CFM
I Sensible
2,151
43,495
5,450
431
16,038
0
2,175
802
0
0
327
12,615
6,231
327
15,218
0
0
2,175
802
62,3161 11,6811 32 860
York BHP042 61,854 11,967 52,464
Total Adjusted System Output61,854 11,967 52,464
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Jul 5 m Jan 12 am
105.0 of
Heating Coil Supply Fan
2800 cfm
105.0 of
Supply Air Ducts
104.7 of
ROOMS
70.0 of
�% Return Air Ducts 4
79.0/64.OoF 1111111 55.0/53.80F
Cooling Coil
Supply Fan
2800 cfm
55.0/53.80
-�j Supply Air Ducts
55.7 / 54.1 of
49.7% R.H. ROOMS
74.0 / 61.6 of
>% Return Air Ducts `S
EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Page:17 of 24 1
1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
SYSTEM NAME FLOOR AREA
Tenant B 1,200
Number of Systems
1
Heating System
Output per System
56,000
Total Output (Btuh)
56,000
Output (Btuh/sgft)
46.7
Cooling System
Output per System
55,000
Total Output (Btuh)
55,000
Total Output (Tons)
4.6
Total Output (Btuh/sqft)
45.8
Total Output (sgft/Ton)
261.8
Air System
CFM per System
2,000
Alrf low (cfm)
2,000
Airflow (cfm/sqft)
1.67
Airflow (cfm/Ton)
436.4
Outside Air (%)
15.0
Outside Air (cfm/sqft)
0.25
Note: values above oiven at ARI conditions
26.0 OF
,
Outside
300 cfm
69.8 of
:DOLING SYS'
11.0 / 77.6 of
Outside Air
300 cfm
72.7/61.4 of
EnergyPro 4.4
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM I
Sensible
Total Room Loads 1,647
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 300
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
29,789
5,000
0
1,489
0
12,222
5,474
0
1,489
46,6251
10,4741
York BHP060 44,043 4,474 34,976
Total Adjusted System Output44,043 4,474 34,976
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Jul 5 m Jan 12 am
63.3 OF p 105.OoF
Heating Coil
105.0 of
Supply Air Ducts
;O
Supply Fan 104.8 of
2000 cfm ROOM
70.0 of
Return Air Ducts I
78.4 / 64.2 of a 55.0 / 53.9 of
User Number: 5950
Cooling Coil
Supply Fan
2000 cfm
55.0 / 53.9 of
-,j Supply Air Ducts
55.7 / 54.2 of
54.2% R.H. ROOMS
72.0 / 61.1 of
�% Return Air Ducts ;
Job Number: C07079
18 of 24
1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
SYSTEM NAME FLOOR AREA
Tenant C 1,200
ENGINEERING CHECKS 11SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
56,000
Total Output (Btuh)
56,000
Output (Btuh/sgft)
46.7
Cooling System
Output per System
55,000
Total Output (Btuh)
55,000
Total Output (Tons)
4.6
Total Output (Btuh/sgft)
45.8
Total Output (sgft/Ton)
261.8
Air System
CFM per System
2,000
Alrflow (cfm)
2,000
Airflow (cfm/sgft)
1.67
Airflow (cfm/Ton)
436.4
Outside Air (%)
15.0
Outside Air (cfm/sqft)
0.25
Note: values above given at ARI conditions
26.0 of
Outside Air
— 0
300 cfm
69.8 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensiblel
Latent
CFM
Sensible
1,566
31,661
5,000
194
7,223
0
1,583
361
0
0
300
11,569
5,573
300
13,994
0
0
1,583
361
48,0011 10,5731 21.939
York BHP060 46,431 2,460 34,976
Total Adjusted System Output as,a31 2,aso 34,s7s
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Jul 5 m Jan 12 am
63.30F � 105.OoF
Heating Coil Supply Fan
2000 cfm
105.0 of
Supply Air Ducts
104.8 of
ROOMS
70.0 of
k Return Air Ducts `i
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0/77.6OF 80.2/64.7OF 55.0/53.8OF 55.0/53.8OF
0I Supply Air Ducts
Outside Air;;,
300 cfm Cooling Coil Supply Fan 55.7 / 54.1 of
2000 cfm 50.3% R.H. ROOMS
74.7/62.0 OF 74.0/61.7 OF
o .. ,.., A.. n, ,..s.. E
I EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Pape:19 of 24 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
SYSTEM NAME FLOOR AREA
Tenant D 1,2 0
26.0 of
Outside
—�-7�
300 cfm
69.8 of
M
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensiblel
Latent
1, CFM
I Sensible
1,615
32,651
5,000
238
8,851
0
1,633
443
0
0
300
11,562
5,574
300
13,981
0
0
1,633
443
49,0941 10,5741 23 718
York BHP060 46,458 2,437 34,976
Total Adjusted System Output 46,458 2,437 34,976
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Jul 5 pm Jan 12 am
,earn Temperatures at Time of Heating Peak)
63.2 OF 0 105.OoF
Heating Coil Supply Fan
2000 cfm
105.0 of
—� Supply Air Ducts
104.8 of
ROOMS
70.0 of
1
K Return Air Ducts 1�
[COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0 / 77.6 of 80.2 / 64.7 of 55.0 / 53.8 of 55.0 / 53.8 of
„rysr.^ Supply Air Ducts
Outside Air y
300 cfm Cooling Coil Supply Fan 55.8 / 54.1 of
2000 cfm 50.3% R.H. ROOMS
74.8/62.0 OF 74.0/61.7 of
h Return Air Ducts ',I
I EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Paae:20 of 24 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
SYSTEM NAME FLOOR AREA
Tenant E 1,200
Number of Systems
1
Heating System
Output per Systerh
56,000
Total Output (Btuh)
56,000
Output (Stuh/sqft)
46.7
Cooling System
Output per System
55,000
Total Output (Btuh)
55,000
Total Output (Tons)
4.6
Total Output (Btuh/sqft)
45.8
Total Output (sgft/Ton)
261.8
Air System
CFM per System
2,000
Alrf low (cfm)
2,000
Airflow (cfm/sqft)
1.67
Alrf low (cfm/Ton)
436.4
Outside Air (°/,)
15.0
Outside Air (cfm/sgft)
0.25
Note: values above given at ARI conditions
26.0 OF
Outside Air
300 cfm
69.8 OF
63.3 OF
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
I Sensible
48,001 10,5731 21 939
York BHP060 46,431 2,460 34,976
Total Adjusted System Output46,431 2,460 34,976
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Jul 5 m Jan 12 am
105.0 OF
Heating Coil
Supply Fan
2000 cfm
105.0 OF
Supply Air Ducts
104.8 OF
ROOMS
70.0 OF
k Return Air Ducts 4
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0/77.6 OF 80.2/64.7 OF 55.0/53.8 OF 55.0/53.8 OF
0 Supply Air Ducts
Outside Air .>
300 cfm Cooling Coil Supply Fan 55.7 / 54.1 OF
2000 cfm 50.3% R.H. ROOMS
74.7/62.00F 74.0 I /61.7 OF
�N Return Air Ducts 4
I EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Page:21 of 24 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
SYSTEM NAME FLOOR AREA
Tenant F (�� 1,200
Number of Systems
1
Heating System
Output per System
56,000
Total Output (Btuh)
56,000
Output (Btuh/sqft)
46.7
Cooling System
Output per System
55,000
Total Output (Btuh)
55,000
Total Output (Tons)
4.6
Total Output (Btuh/sgft)
45.8
Total Output (sgft/Ton)
261.8
Air System
CFM per System
2,000
Alrf low (cfm)
2,000
Airflow (cfm/sgft)
1.67
Airflow (cfm/Ton)
436.4
Outside Air (°/,)
24.0
Outside Air (cfm/sqft)
0.40
Note: values above given at ARI conditions
26.0 OF
Outside
��
480 cfm
69.8 of
111.0 / 77.6 OF
0
Outside
480 cfm
74.7/62.1 °F
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensiblel
Latent
I CFM I
Sensible
Total Room Loads 1,480
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 480
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
29,917
6,120
0
1,496
0
18,531
8,787
0
1,496
1 53,7981
14,9071
HVAC EQUIPMENT SELECTION
York BHP060 49,525 634 34,976
Total Adjusted System Output49,525 634 34,976
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Jul 5 p1m Jan 12 am
59.3°F 105.0°F
Heating Coil Supply Fan
2000 cfm
105.0 OF
3i,Supply Air Ducts
104.8 OF
ROOMS
70.0 OF
k Return Air Ducts `i
83.4/66.30F M 55.0/53.70F
Cooling Coil Supply Fan
2000 cfm
55.0/53.70
-� Supply Air Ducts
55.7 / 54.0 OF
50.6% R.H. ROOMS
74.0 / 61.8 OF
�% Return Air Ducts '�
EnergyPro 4.4 by EnergySoft • User Number: 5950 Job Number: C07079 Page:22 of 24
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
SYSTEM NAME FLOOR AREA
Tenant G __1,2 0 0
ENGINEERING CHECKS 1SYSTEM LOAD
II
Number of S stems
1
Heating System
Output per System
56,000
Total Output (Btuh)
56,000
Output (Btuh/sgft)
46.7
Cooling System
Output per System
55,000
Total Output (Btuh)
55,000
Total Output (Tons)
4.6
Total Output (Btuh/sgft)
45.8
Total Output (sgft/Ton)
261.8
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sgft)
1.67
Alrflow (cfm/Ton)
436.4
Outside Air (%)
15.0
Outside Air (cfm/sgft)
0.25
Note: values above given at ARI conditions .
26.0 of
Outside
'—�
300 cfm
69.8 of
11.0 / 77.6 OF
Outside
er—y
300 cfm
74.7/62.0 OF
4.4
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM I
Sensiblel
Latent
I CFM
I Sensible
47,900 10,573 21 939
York BHP060 46,429 2,463 34,976
Total Adjusted System Output 46,429 2,463 34,976
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Jul 5 1 Jan 12 am
63.30F ` 105.0 OF
Heating Coil Supply Fan
2000 cfm
105.0 of
Supply Air Ducts
104.8 of
ROOMS
70.0 of
�% Return Air Ducts
80.2 / 64.7 of 4 55.0 / 53.8 of
User Number: 5950
Cooling Coil
Supply Fan
2000 cfm
55.0/53.80
—�j Supply Air Ducts
55.7/54.1OF
50.3% R.H. ROOMS
74.0 / 61.7 OF
Return Air Ducts
Job Number: C07079
o124
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Dunes Retail Center - Retail 3 2/28/2008
SYSTEM NAME FLOOR AREA
Tenant H 1.500
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems
2
Heating System
Output per System
42,000
Total Output (Btuh)
84,000
Output (Btuh/sqft)
56.0
Cooling System
Output per System
42,000
Total Output (Btuh)
84,000
Total Output (Tons)
7.0
Total Output (Btuh/sgft)
56.0
Total Output (sgft/Ton)
214.3
Air System
CFM per System
1,400
Airflow (cim)
2,800
Airflow (cfm/sgft)
1.87
Alrflow (cfm/Ton)
400.0
Outside Air (%)
13.4
Outside Air (cim/sqft)
0.25
Note: values above given at ARI conditions
26.0 OF
?�
Outside Air
375 cfm
74.7 OF
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
ICOILHTG.PEAK
CFM
I Sensiblel
Latent
1. CFM
I Sensible
2,082
44,304
6,250
F 614
19,601
0
2,215
980
0
0
375
14,469
7,112
375
19,424
0
0
2,215
980
65,298 13,362 40 985
HVAC EQUIPMENT SELECTION
York BHP042 64,374 9,830 52,464
Total Adjusted System Output4,374 9,830 52,464
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
68.2°F rf= 105.0°F
Heating Coil
105.0 OF
Supply Air Ducts
Supply Fan 104.7 OF
2800 cfm ROOMS
75.0 OF
k Return Air Ducts 4
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) I
12.0 / 77.9 OF
Outside Air
375 cfm
75.7/62.2 °F
80.6 / 64.6 OF = 55.0 / 53.7 OF 55.0 / 53.7 OF
Cooling Coil
xf Supply Air Ducts
�O
Supply Fan 55.7 / 54.0 of
2800 cfm 48.1% R.H. ROOMS
75.0 / 62.0 OF
Return Air Ducts
EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Paoe:24 of 24 1