08-0401 (RC) Title 24I TITLE 24 REPORT Title 4 Re ofpr: The Dunes etail en er - Retail 3 79-710 Highway 111 #J05' La Quinta, CA 92253 C?a•Cc-� �d � �� �D5 Project Designer: KKE Architects 525 East Colorado Boulevard Pasadena, CA 91101 (626) 796-8230 Report Prepared By: C+J Technical Solutions C&J Technical Solutions And Services, Inc. 4000 Valley Blvd., Suite 103 Walnut, CA 91789 (909) 598-6067 Job Number: C07079 MAR 0 3 2008 Date: BY 2/28/2008 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: C07079 User Number: 5950 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form ENV -MM Envelope Mandatory Measures 14 Form MECH-MM Mechanical Mandatory Measures 15 HVAC System Heating and Cooling Loads Summary 17 EnergyPro 4.4 by EnergySoft Job Number: C07079 User Number: 5950 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME This Certificate of Compliance Ilsts the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the DATE The Dunes Retail Center - Retail 3 BUILDING CONDITIONED FLOOR AREA 10,008 Sq,Ft. 2/28/2008 PROJECT ADDRESS NONRESIDENTIAL HIGH RISE RESIDENTIAL 0 HOTEL/MOTEL GUEST ROOM 79-710 Highway 111 La Quinta NEW CONSTRUCTION ADDITION ❑ EXISTING + ADDITION/ALTERATION Building Permit # PRINCIPAL DESIGNER - ENVELOPE TELEPHONE California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. KKE Architects (626) 796-8230 contractor performing this work. DOCUMENTATION AUTHOR TELEPHONE 1 Checked by/Date C&J Technical Solutions And Services, Inc. (909) 598-6067 Enforcement Agency Use GENERAL INFORMATION This Certificate of Compliance Ilsts the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. DATE OF PLANS BUILDING CONDITIONED FLOOR AREA 10,008 Sq,Ft. CLIMATE ZONE 15 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL 0 HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ADDITION ❑ EXISTING + ADDITION/ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance Ilsts the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation Is ac urate and complete. DOCUMENTATION AUTHOR SIGNATU DAT C+J Technical Solutions he Principal Designer hereby certifys that the proposed building de gn represe d ' t 's t of construction do u ents is consistent with the other compliance forms and worksheets, with t specificati s nd w h any other calculations bmitted With this permit application. The proposed building as designed meets the ergy effici n rements contained in sec tns 110, 6, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. R ❑ ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. 0 ❑ 2.1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. R R ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATURE LIC. NO. DATE KKE Architects LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Lighting Compliance Not In The Scope Of Required Forms This UUMILLdl PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures MECH-1 MECH-2 MECH-3 MECH-5 Required Forms PRINCIPAL MECHANICAL DESIGNER - NAME Si UR LIC. NO. DA Polar Barr Air Conditioning Inc. IS1911&)'j I EneravPro 4.4 by EneravSoft User Number: 5950 Job Number: C07079 Paae:3 of 24 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF - PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 ANNUAL TDV ENERGY USE SUMMARY (kBtu/sgft-yr) ENERGY COMPONENT Standard Design 1 . Proposed Design 8 Compliance Margin Space Heating' . Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process TOTALS: Percent better than Standard: 0.88 0.66 0.22 343.56 260.78 82.77 54.82 60.08 -5.26 o.o0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 172.79 172.79 0.00 91.58 91.58 0.00 o.o0 0.00 0.00 663.63 585.90 77.73 1,316 11.7%° ( 11.7% eXCIL BUILDING COMPL r GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of. Zones N o deg Conditioned Floor Area 10,008 sgft. Unconditioned Floor Area 0 sgft. Conditioned Footprint Area 10,008 sgft. Fuel Type Natural Gas 1 10 8 950 Orientation Gross Area Glazing Area Glazing Ratio Front Elevation N) 950 sgft.• 427 sgft. 44.9% .' Left Elevation (E) - 1,700 sgft. 107 sgft. 6.30 Rear Elevation S 600 sgft. 250 sgft. 41.6% Right Elevation Total Roof (W) 2,235 sgft. 5,485 sgft. 10,008 sgft. 1,316 sgft. sgft. sgft. 58.99/6 2,100 =:� Standard Proposed Lighting Power Density 1.616 wisgft. 1.616 wisgn. Prescriptive Env. Heat Loss 1,687 etum 1,787 stun, Prescriptive Env. Heat Gain 183,942 etum-F 220,179 Btum-F Remarks: Run Initiation Time: 02/28/08 16:35:09 Run Code: 1204245309 EnergyPro 4.4 by EnergySoft User Number: 5950 1Job Number: C07079 Page:4 of 24 PERFORMANCE CERTIFICATE OF COMPLIANCE Part of PERF -1 PROJECT NAME The Dunes Retail Center - Retail 3 DATE 2/28/2008 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft.) Inst. LPD (W/sf)l Ctrl. Allowed LPD Proc. Credits Area Tailored Loads (W/sf)2 /sf 3 /sf 4 (W/sf) Tenant A Zone 1 Retail Sales, Wholesale 1,308 -1.700 Tenant B Zone 1 Retail Sales, Wholesale 1,200 -1.700 Tenant C Zonal Retail Sales, Wholesale 1,200 -1.700 Tenant D Zonal Retail Sales, Wholesale 1,200 -1.700 Tenant E Zone 1 Retail Sales, Wholesale 1,200 -1.700 Tenant F .- Zone 1 Barber and Beauty Shop 1,200 -1.000 Tenant G Zonell Retail Sales, Wholesale 1,200 -1.700 Tenant H Zonell Retail Sales Wholesale 1,500 "1.700 Notes: 1. See LTG -2-C (Items marked with asterisk, see LTG -2 -C by others) 2. See LTG -4-C 3. See LTG -5-C (by others) 4. See LTG -6-C Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the Items specitiea In tins cnecKus[. i nese items require speciai written fusuncazion and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "York BHP060" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. The HVAC System "York BHP042" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stam I EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Page:5 of 24 1 CERTIFICATE OF COMPLIANCE ENV -7-C PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 OPAQUE SURFACES # Surface Type Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Cond: Status Joint Appendix IV Reference Location / Comments 1 Wall 461 0.074 R-19 R-0.0 0 90 New 09-A5 Zonell 2 Wall 250 0.074 R-19 R-0.0 90 90 New 09-A5 Zone 1 3 Wall 347 0.074 R-19 R-0.0 270 90 New 09-A5 Zone 1 4 Roof 1,308 0.036 R-30 R-0.0 0 0 New 02-A9 Zonell 5 lWall 1 200 0.074 R-19 R-0.01 90 90 1 New 09-A5 Zonell 6 Wall 12 0.074 R-19 R-0.0 270 90 New 09-A5 Zone 1 7 Roof 1,200 0.036 R-30 R-0.0 0 0 New 02-A9 Zonell 8 Wall 200 0.074 R-19 R-0.0 90 90 New 09-A5 Zone 1 9 Wall 12 0.074 R-19 R-0.0 270 90 New 09-A5 Zone 1 10 Roof 1,200 0.036 R-30 R-0.0 0 0 New 02-A9 Zone'l 11 Wall 200 0.074 R-19 R-0.0 90 90 New 09-A5 Zone 1 12 Wall 1 512 0.074 R-19 R-0.0 270 90 New 09-A5 Zonell 13 Roof 1,200 0.036 R-30 R-0.0 0 0 New 02-A9 Zone 1 14 Wall 200 0.074 R-19 R-0.0 90 90 New 09-A5 Zonell 15 Wall 12 0.074 R-19 R-0.0 270 90 New 09-A5 Zone 1 16 Roof 1,200 0.036 R-30 R-0.0 0 0 New 02-A9 Zone 1 17 Wall 200 0.074 R-19 R-0.0 90 90 New 09-A5 lZonel 18 Wall 1 0.074 R-19 R-0.0 270 90 New 09-A5 jZonel 19 lRoof 1 1,2001 0.036 R-30 R-0.01 0 0 New 02-A9 jZonel 20 lWall 1 2001 0.074 R-1 91 8-0.0 90 90 New 09-A5 IZonel Removed) 1-1 More than or equal to 10,000 sq.tt. of site-bullt fenestration area must Include a label certificate either Issued by NFRC or provide a CEC Default Label Certificate using the default LI -factors from Standards Table 116-A and B. Certificate shall be filed In the contractor's omlect office during construction and In the building managers office atter construction # ITYpe Area U -Fac? SHGC2 Act. Azm. Cond. Stat. Glazing Type Location/ Comments 1 Window Front N 75 0.560 NFRC 0.41 NFRC 0 New SOLARBAN 60 LOW -E Zone 1 2 Window Front N 140 0.560 NFRC 0.41 NFRC 0 New SOLARBAN 60 LOW -E Zone 1 3 Window Front N 24 0.560 NFRC 0.41 NFRC 0 New SOLARBAN 60 LOW -E Zone 1 4 Window Right W 48 0.560 NFRC 0.41 NFRC 270 New SOLARBAN 60 LOW -E Zone 1 5 Window Right W 140 0.560 NFRC 0.41 NFRC 2701 New SOLARBAN 60 LOW -E Zone 1 6 Window Right (W) 140 0.560 NFRC 0.41, NFRC 270 New SOLARBAN 60 LOW -E Zone 1 7 Window Right W 48 0.560INFRCI 0.41 NFRC 270 New SOLARBAN 60 LOW -E Zone 1 8 Window Right W 140 0.560 NFRC 0.41 NFRC 270 New SOLARBAN 60 LOW -E Zone 1 9 Window Right W 48 0.560 NFRC 0.41 NFRC 270 New SOLARBAN 60 LOW -E Zone 1 10 Window Right (W) 140 0.560 NFRC 0.41 NFRC 270 New SOLARBAN 60 LOW -E Zone 1 11 Window Right W) 48 0.560 NFRC 0.41 NFRC 270 New SOLARBAN 60 LOW -E Zone 1 12 Window Right W 140 0.560 NFRC 0.41 NFRC 270 New SOLARBAN 60 LOW -E Zone 1 13 lWindow Right W 48 0.560 NFRC 0.41 INFRCI 2701 New I SOLARBAN 60 LOW -E Zone 1 (1) U -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2 SHGC Type: 116.8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. Hat. Dist. Len. H t. 1 None 0.76 10.0 7.0 4.0 0.1 4.0 4.0 2 None 0.76 3 None 0.76 7.0 3.0 4.0 0.1 4.0 4.0 4 None 0.76 7.0 3.0 4.0 0.1 4.0 4.0 5 None 0.76 6 None 0.76 8.0 13.3 4.0 0.1 4.0 4.0 7 None 0.76 7.0 3.0 4.0 0.1 4.0 4.0 8 None 0.76 9 None 0.76 8.0 3.0 4.0 0.1 4.0 4.0 10 None 0.76 10.5 7.0 3.0 0.1 3.0 3.0 11 None 0.76 8.0 3.0 1 3.0 0.1 3.0 3.0 12 None 0.76 13 None 0.76 8.0 3.0 1 4.0 0.1 4.0 4.0 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES 1-1The proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 W, a ceiling height greater than 15 feet, and an LPD for general lighting of at least 0.5 W/ft2. See Section 143(c). If this box Is checked, ENV -4-C must be filled out. when submitting under the Prescriptive Compliance Approach. 1 EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Paae:6 of 24 1 CERTIFICATE OF COMPLIANCE ENV -1-C PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 OPAQUE SURFACES # Surface Type Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Cond: I Status Joint Appendix IV Reference Location / Comments 21 Wall 12 0.074 R-19 R-0.0 270 90 1 New 09-A5 Zone 1 22 Roof 1,20 0.036 R-30 R-0.0 0 0 New 02-A9 Zone 1 23 Wall 62 0.074 R-19 R-0.0 0 90 New 09-A5 Zone 1 24 Wall 350 0.074 R-19 R-0.0 180 90 New 09-A5 Zone 1 25 Wall 1 143 0.074 R-19 R-0.0 90 90 New 09-A5 Zone 1 26 Roof 1,500 0.036 R-30 R-0.0 0 0 New 02-A9 Zone 1 New SOLARBAN 60 LOW -E Zone 1 21 Window Rear S 94 0.560 NFRC 0.41 NFRC 180 New SOLARBAN 60 LOW -E Zone 1 22 Window Rear S 107 0.560 NFRC 0.41 NFRC 180 New SOLARBAN 60 LOW -E Zone 1 23 Window Left (E) 107 0.560 NFRC 0.41 NFRC 90 New SOLARBAN 60 LOW -E Zone 1 F-1 More than or equal to 10,000 sq.lt. of she-bulft fenestration area must Include a label certificate either Issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from Standards Table 116-A and B. Cert0lcate shall be filed In the contractor's orolect office during construction and In the building managers office after construction # 1 Type Area U -Fac' SHGC2 Act. Azm. Cond. Stat. Glazing Type Location/ Comments 14 Window Ri ht W 48 0.560 NFRC 0.41 NFRC 270 New SOLARBAN 60 LOW -E Zone 1 15 Window Right W 140 0.560 NFRC 0.41 NFRC 270 New SOLARBAN 60 LOW -E Zone 1 16 Window Right W 140 0.560 NFRC 0.41 NFRC 270 New SOLARBAN 60 LOW -E Zone 1 17 Window Right W 48 0.560 NFRC 0.41 NFRC 270 New SOLARBAN 60 LOW -E Zone 1 18 Window Front N 140 0.560 NFRC 0.41 NFRC 01 New SOLARBAN 60 LOW -E Zone 1 19 Window Front (N) 48 0.560 NFRC 0.41 NFRC 0 New SOLARBAN 60 LOW -E Zone 1 20 lWindow Rear S 48 0.560 NFRCI 0.41 NFRC 180 New SOLARBAN 60 LOW -E Zone 1 21 Window Rear S 94 0.560 NFRC 0.41 NFRC 180 New SOLARBAN 60 LOW -E Zone 1 22 Window Rear S 107 0.560 NFRC 0.41 NFRC 180 New SOLARBAN 60 LOW -E Zone 1 23 Window Left (E) 107 0.560 NFRC 0.41 NFRC 90 New SOLARBAN 60 LOW -E Zone 1 (1) 1.1 -factor Type: 11 6-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2 SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING. ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 14 None 0.76 8.0 3.0 4.0 0.1 4.0 4.0 15 None 0.76 16 None 0.76 17 None 0.76 7.0 3.0 4.0 0.1 4.0 4.0 18 None 0.76 8.0 13.3 4.0 0.1 4.0 4.0 19 None 0.76 8.0 3.0 4.0 0.1 4.0 4.0 20 None 0.76 8.0 3.0 4.0 0.1 4.0 4.0 21 None 0.76 10.0 9.0 2.0 0.1 2.0 2.0 22 None 0.76 8.0 10.0 4.0 0.1 4.0 4.0 23 None 0.76 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 ft2, a telling height greeter than 15 feet, end an LPD for general lighting of at least 0.5 W1112. See Section 143(x). If this box Is checked, ENV -4-C must be filled out. when submitting under the Prescriptive Compliance Approach. EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Paoe:7 of 24 1 (CERTIFICATE OF COMPLIANCE MECH-I-C PROJECT NAME DATE The Dunes Retail Center - Retail 3 1 2/28/2008 ueslgner: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or�space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates. and ooeratina and maintenance information meet the recuirements of Section 10-103(b) and Title 24 Part 6. STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require construction Inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit serves 5,000112 ofspaca or less and 25% or more of the ducts are In nonconoitioned or somiconditloned space (Ore an attic. New systems that most the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls Installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VA fan volume controls installed on new or existing systems must be tested ❑ MECH-8-A:-Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 SWIM -Water-loop Heat Pump Controls Applies to all new watedoop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all now distribution pumps onnow variable flow chilled hydrant: heat pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment re uiring acceptance testing EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Page:8 of 24 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance AIR SYSTEMS, Central or Single one Tenant A Tenant B Tenant C 2 1 1 Reference on Plans or Specification 1 112(a) 7.70 HSPF 7.70 HSPF 7.70 HSPF 112(a) 13.0 SEER / 11.3 EER 13.0 SEER / 11.2 EER 13.0 SEER / 11.2 EER 112(b) Yes Yes Yes 112(c), 115(a) n/a n/a n/a 121(b) No No No 121 b 327 cfm 300 cfm 300 cfm 121 c No No No 121(c) No No No 121 c 122(e) Programmable Switch Programmable Switch Pro rammable Switch 122(e) Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required 122 Gravity Gravity Gravity 122(g) n/a n/a n/a 123 No 124 R-4.2 I R-4.2 I R-4.2 144 a & b n/a n/a n/a 144 ja & b 52,464 btuh 34,976 btuh 34,976 btuh 144 a & b n/a n/a n/a 144 a & b 61,854 btuh 44,043 btuh 46,431 btuh 144 c Constant Volume Constant Volume Constant Volume 144 (c) 144 c No No No 144 d No No No 144 a No Economizer No Economizer No Economizer 144 Constant Temp Constant Ternp Constant Tem 144(f) Constant Temp Constant Temp Constant Temp 144 k No No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing Is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. I Faun Inniayon I lme: 02/2S/OS 16:35:09 Hun Gocfe: 1204245309 1 EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Page:9 of 24 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance 1: For each central and single zone air systems (or group of similar units) fill In the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes If System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing Is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. NATFA TO FIFI n - Fnr Rrrilrlinn npnnrtmpnt Ilcp nniv AIR SYSTEMS, Central or Single one Tenant D Tenant E Tenant F 1 1 1 Reference on Plans or Specification 1 112(a) 7.70 HSPF 7.70 HSPF 7.70 HSPF 112(a) 13.0 SEER / 11.2 EER 13.0 SEER / 11.2 EER 13.0 SEER / 11.2 EER 112(b) Yes Yes Yes 112(c), 115(a). n/a n/a n/a 121(b) No No No 121(b) 300 cfm 300 cfm 480 cfm 121 c No No No 121(c) No No No 121 c 122 a Pro rammable Switch Programmable Switch Procirammable Switch 122(e) Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required 122 Gravity Gravity Constant Temp 122(g) n/a --Gravity n/a n/a 123 No 124 1 R-4.2 I R-4.2 I R-4.2 144 a & b n/a n/a n/a 144 a & b 34,976 btuh 34,976 btuh 34,976 btuh 144 a & b n/a n/a n/a 144 a & b 46,458 btuh 46,431 btuh 49,525 btuh 144 c Constant Volume Constant Volume Constant Volume 144 (c) 144 c No No No 144 d No No No 144(s) No Economizer No Economizer No Economizer 144 Constant Temp Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp F144 (k) No No No Run Initiation Time: 02/28/08 16:35:09 Run Code: 1204245309 EnergyPro 4.4 by EnergvSoft User Number: 5950 Job Number: C07079 Page:10 of 24 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous HeaVCool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance AIR SYSTEMS, Central or Single Zone Tenant G Tenant H 1 2 Reference on Plans or Specification t 112(a) 7.70 HSPF 7.70 HSPF 144 a & b 112(a) 13.0 SEER / 11.2 EER 13.0 SEER / 11.3 EER n/a 112(b) Yes Yes 64,374 btuh 112(c), 115(a) n/a n/a 144 (c 121(b) No No No 121(b) 300 cfm 375 cfm No 121 c No No 144 121(c) No No Constant Temp 121(c), 122(e) Programmable Switch Programmable Switch No 122(e) Heating & Cooling Required Heating & Cooling Require 122 Gravity Gravity 122(g) n/a n/a 123 124 R-4.2 R-4.2 144 a & b n/a n/a 144 a & b 34,976 btuh 52,464 btuh 144 a & b n/a n/a 144 a & b 46,429 btuh 64,374 btuh 144 c Constant Volume Constant Volume 144 (c 144 c No No 144 d No No 144 a No Economizer No Economizer 144 Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp 144 k) No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. I Hun Initiation Time: u2/2S/u8 16:35:09 Run Code: 1204245309 1 EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Paoe:11 of 24 1 MECHANICAL VENTILATION MECH-3-CI PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 PRESCRIPTIVE REHEAT TLIMITATION (Section 144(d)) MECHANICAL VENTILATION Section 121(b)2) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H I I J K L M N ZONE/SYSTEM 0 n3 a vim— ° a `W'0 -n T�3 c �-5.Cr 3 xD C)M ..y� Z C3 cQ �cD coy Man T °'� ' � m� x° -nC-A "�� � ado ox o � ��D � n;m -A .m �Dfo �' ca �� cpm° nu) � - 9N n �°° rn x .0 �a o° a3d o°x Oyo 0_ o N ='Q a 09 -. m ' w n Zone 1 1,308 0.25 327 327 327 Tenant A Total 327 327 Zone 1 1,20C 0.25 300 300 300 Tenant B Total 300 300 Zone 1 1,200 0.25 300 300 300 Tenant C Total 300 3001 1 Zone 1 1,200 0.25 300 300 300 Tenant D Total 300 300 Zone 1 1,200 0.25 300 300 300 Tenant E Total 300 300 Zone 1 1,200 0.40 4801 1 480 480 Tenant F r' ! s Total 480 480 Zone 1 1,200 0.25 300 1 300 300 Tenant G Total 300 300 Zone 1 1.50C 0.25 375 375 375 Tenant H Total 1 375 3751 1 C Minimum ventilation rate per Section 121 Table 121-A E Based on fi seat or the greater of the expected number of occupants and 50% of the CBC occupant load foregress purposes fors aces without fixed seating. H Required Ventilation Air (REO'D V.A.) is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS (column D or G). I Must be greater than orequal to H or use Transfer Alr column N to make up the difference. J Design fan supply cfm (Fan CFM) x 30%; or K Condition area (ft. sq.) x 04 cfm/ft. sq.; or L Maximum of Columns H, J, K, or 300 cfm M IThIs must be less than orequal to Column L and greater that orequal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column 1) Is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column 1) and the Design Minimum Air (column M), column H - M. EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Page: 12 of 24 MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME The Dunes Retail Center - Retail 3 COOLING DATE 2/28/2008 CHILLER AND TOWER SUMMARY System Type QN Efficiency Tons PUMPS Output Equipment Name Equipment Type Economizer Type Tot. City GPM BHP Motor Drive Eff. Eff. Pump Control 7.70 HSPF -.City. 13.0 SEER/ 11.3 EER New No Economizer York BHP060 Packaged DX 6 56,000 0.0 7.70 HSPF 55,000 13.0 SEER / 11.2 EER New No Economizer DHW BOILER SUMMARY Energy Standby TANK INSUL. Rated Vol. Condition Factor Loss or Ext. Svstem Name Svstem Tvoe Distribution Tvoe atv InDut (Gals.) I Status i or RE Pilot I R -Val. CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type QN Output Aux. kW Eff. Output EfflclencV Condition Status Economizer Type York BHP042 Packaged DX 4 42,000 0.0 7.70 HSPF 42,000 13.0 SEER/ 11.3 EER New No Economizer York BHP060 Packaged DX 6 56,000 0.0 7.70 HSPF 55,000 13.0 SEER / 11.2 EER New No Economizer ENVELOPE MANDATORY MEASURES ENV -MM PROJECT NAME DATE The Dunes Retail Center - Retail 3 1 2/28/2008 DESCRIPTION Designer Enforcement X] §118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for Insulating material, Title 20, Chapter 4, Article 3. R§118(c) All Insulating Materials shall be Installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. X❑ §117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. X❑ §116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). F-] § 116(a)1 Manufactured Doors and Windows Installed shall have air Infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls In nonresidential buildings shall have Insulation with an Installed R -value of no less than R-13 between framing members. EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Page:14 of 24 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies 0 ' § 11 Any appliance for which there is a California standard established In the .Appliance Efficiency Regulations will comply with the applicable standard. a §115(a) Fan type central furnaces shall not have a pilot light. §123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. X❑ §124 Air handling duct systems shall be Installed and Insulated In compliance with Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards. Controls §122(e) Each space conditioning system shall be Installed with one of the following: X] §122(e)1 A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be Installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power Is Interrupted; or §122(e)1 B An occupancy sensor to control the operating period of the system; or ❑ §122(e)1 C A41 -hour timer that can be manually operated to control the operating period of the system. 0 §122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. §122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with Isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off Independently of other Isolation areas; and shall be controlled by a time control device as described above. ❑ §122(a&b) Each space conditioning system shall be controlled by an Individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling Is shut off or reduced to a minimum. RI §122(c) Thermostats shall have numeric setpoints In degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. §112(b) Heat pumps shall be Installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Pagel5 of 24 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME DATE The Dunes Retail Center - Retail 3 1 2/28/2008 Description Designer Enforcement Ventilation ❑X §121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. ❑ §122(f) Gravity or automatic dampers Interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. §122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. §121 (f)i Air Balancing: The system shall be balanced In accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or §121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or ❑ §121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or §121(f)4 Another method approved by the Commission. Service Water Heating Systems ❑ §113(b)2 If a circulating hot water system Is Installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water Is not required. ❑ §113(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Pagel6 of 24 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 SYSTEM NAME FLOOR AREA Tenant A 1,308 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 Heating System Output per System 42,000 Total Output (Btuh) 84,000 Output (Btuh/sqft) 64.2 Cooling System Output per System 42,000 Total Output (Btuh) 84,000 Total Output (Tons) 7.0 Total Output (Btuh/sqft) 64.2 Total Output (sgft/Ton) 186.9 Air System CFM per System 1,400 Airflow (cfm) 2,800 Airflow (cfm/sqft) 2.14 Airflow (cfm/Ton) 400.0 Outside Air (%) 11.7 Outside Air (cfm/sqft) 0.25 Note: values above HEATING SYSTE 26.0 OF Outside Air 327 cfm 69.7 of 11.0 / 77.6 of Outside Air 327 cfm 74.7/61.8 ° F at ARI conditions YCHROMETRICS 64.60F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 2,151 43,495 5,450 431 16,038 0 2,175 802 0 0 327 12,615 6,231 327 15,218 0 0 2,175 802 62,3161 11,6811 32 860 York BHP042 61,854 11,967 52,464 Total Adjusted System Output61,854 11,967 52,464 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 5 m Jan 12 am 105.0 of Heating Coil Supply Fan 2800 cfm 105.0 of Supply Air Ducts 104.7 of ROOMS 70.0 of �% Return Air Ducts 4 79.0/64.OoF 1111111 55.0/53.80F Cooling Coil Supply Fan 2800 cfm 55.0/53.80 -�j Supply Air Ducts 55.7 / 54.1 of 49.7% R.H. ROOMS 74.0 / 61.6 of >% Return Air Ducts `S EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Page:17 of 24 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 SYSTEM NAME FLOOR AREA Tenant B 1,200 Number of Systems 1 Heating System Output per System 56,000 Total Output (Btuh) 56,000 Output (Btuh/sgft) 46.7 Cooling System Output per System 55,000 Total Output (Btuh) 55,000 Total Output (Tons) 4.6 Total Output (Btuh/sqft) 45.8 Total Output (sgft/Ton) 261.8 Air System CFM per System 2,000 Alrf low (cfm) 2,000 Airflow (cfm/sqft) 1.67 Airflow (cfm/Ton) 436.4 Outside Air (%) 15.0 Outside Air (cfm/sqft) 0.25 Note: values above oiven at ARI conditions 26.0 OF , Outside 300 cfm 69.8 of :DOLING SYS' 11.0 / 77.6 of Outside Air 300 cfm 72.7/61.4 of EnergyPro 4.4 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible Total Room Loads 1,647 Return Vented Lighting Return Air Ducts Return Fan Ventilation 300 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 29,789 5,000 0 1,489 0 12,222 5,474 0 1,489 46,6251 10,4741 York BHP060 44,043 4,474 34,976 Total Adjusted System Output44,043 4,474 34,976 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 5 m Jan 12 am 63.3 OF p 105.OoF Heating Coil 105.0 of Supply Air Ducts ;O Supply Fan 104.8 of 2000 cfm ROOM 70.0 of Return Air Ducts I 78.4 / 64.2 of a 55.0 / 53.9 of User Number: 5950 Cooling Coil Supply Fan 2000 cfm 55.0 / 53.9 of -,j Supply Air Ducts 55.7 / 54.2 of 54.2% R.H. ROOMS 72.0 / 61.1 of �% Return Air Ducts ; Job Number: C07079 18 of 24 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 SYSTEM NAME FLOOR AREA Tenant C 1,200 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 56,000 Total Output (Btuh) 56,000 Output (Btuh/sgft) 46.7 Cooling System Output per System 55,000 Total Output (Btuh) 55,000 Total Output (Tons) 4.6 Total Output (Btuh/sgft) 45.8 Total Output (sgft/Ton) 261.8 Air System CFM per System 2,000 Alrflow (cfm) 2,000 Airflow (cfm/sgft) 1.67 Airflow (cfm/Ton) 436.4 Outside Air (%) 15.0 Outside Air (cfm/sqft) 0.25 Note: values above given at ARI conditions 26.0 of Outside Air — 0 300 cfm 69.8 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensiblel Latent CFM Sensible 1,566 31,661 5,000 194 7,223 0 1,583 361 0 0 300 11,569 5,573 300 13,994 0 0 1,583 361 48,0011 10,5731 21.939 York BHP060 46,431 2,460 34,976 Total Adjusted System Output as,a31 2,aso 34,s7s (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 5 m Jan 12 am 63.30F � 105.OoF Heating Coil Supply Fan 2000 cfm 105.0 of Supply Air Ducts 104.8 of ROOMS 70.0 of k Return Air Ducts `i COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6OF 80.2/64.7OF 55.0/53.8OF 55.0/53.8OF 0I Supply Air Ducts Outside Air;;, 300 cfm Cooling Coil Supply Fan 55.7 / 54.1 of 2000 cfm 50.3% R.H. ROOMS 74.7/62.0 OF 74.0/61.7 OF o .. ,.., A.. n, ,..s.. E I EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Pape:19 of 24 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 SYSTEM NAME FLOOR AREA Tenant D 1,2 0 26.0 of Outside —�-7� 300 cfm 69.8 of M Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent 1, CFM I Sensible 1,615 32,651 5,000 238 8,851 0 1,633 443 0 0 300 11,562 5,574 300 13,981 0 0 1,633 443 49,0941 10,5741 23 718 York BHP060 46,458 2,437 34,976 Total Adjusted System Output 46,458 2,437 34,976 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 5 pm Jan 12 am ,earn Temperatures at Time of Heating Peak) 63.2 OF 0 105.OoF Heating Coil Supply Fan 2000 cfm 105.0 of —� Supply Air Ducts 104.8 of ROOMS 70.0 of 1 K Return Air Ducts 1� [COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 of 80.2 / 64.7 of 55.0 / 53.8 of 55.0 / 53.8 of „rysr.^ Supply Air Ducts Outside Air y 300 cfm Cooling Coil Supply Fan 55.8 / 54.1 of 2000 cfm 50.3% R.H. ROOMS 74.8/62.0 OF 74.0/61.7 of h Return Air Ducts ',I I EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Paae:20 of 24 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 SYSTEM NAME FLOOR AREA Tenant E 1,200 Number of Systems 1 Heating System Output per Systerh 56,000 Total Output (Btuh) 56,000 Output (Stuh/sqft) 46.7 Cooling System Output per System 55,000 Total Output (Btuh) 55,000 Total Output (Tons) 4.6 Total Output (Btuh/sqft) 45.8 Total Output (sgft/Ton) 261.8 Air System CFM per System 2,000 Alrf low (cfm) 2,000 Airflow (cfm/sqft) 1.67 Alrf low (cfm/Ton) 436.4 Outside Air (°/,) 15.0 Outside Air (cfm/sgft) 0.25 Note: values above given at ARI conditions 26.0 OF Outside Air 300 cfm 69.8 OF 63.3 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 48,001 10,5731 21 939 York BHP060 46,431 2,460 34,976 Total Adjusted System Output46,431 2,460 34,976 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 5 m Jan 12 am 105.0 OF Heating Coil Supply Fan 2000 cfm 105.0 OF Supply Air Ducts 104.8 OF ROOMS 70.0 OF k Return Air Ducts 4 DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6 OF 80.2/64.7 OF 55.0/53.8 OF 55.0/53.8 OF 0 Supply Air Ducts Outside Air .> 300 cfm Cooling Coil Supply Fan 55.7 / 54.1 OF 2000 cfm 50.3% R.H. ROOMS 74.7/62.00F 74.0 I /61.7 OF �N Return Air Ducts 4 I EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Page:21 of 24 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 SYSTEM NAME FLOOR AREA Tenant F (�� 1,200 Number of Systems 1 Heating System Output per System 56,000 Total Output (Btuh) 56,000 Output (Btuh/sqft) 46.7 Cooling System Output per System 55,000 Total Output (Btuh) 55,000 Total Output (Tons) 4.6 Total Output (Btuh/sgft) 45.8 Total Output (sgft/Ton) 261.8 Air System CFM per System 2,000 Alrf low (cfm) 2,000 Airflow (cfm/sgft) 1.67 Airflow (cfm/Ton) 436.4 Outside Air (°/,) 24.0 Outside Air (cfm/sqft) 0.40 Note: values above given at ARI conditions 26.0 OF Outside �� 480 cfm 69.8 of 111.0 / 77.6 OF 0 Outside 480 cfm 74.7/62.1 °F COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent I CFM I Sensible Total Room Loads 1,480 Return Vented Lighting Return Air Ducts Return Fan Ventilation 480 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 29,917 6,120 0 1,496 0 18,531 8,787 0 1,496 1 53,7981 14,9071 HVAC EQUIPMENT SELECTION York BHP060 49,525 634 34,976 Total Adjusted System Output49,525 634 34,976 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 5 p1m Jan 12 am 59.3°F 105.0°F Heating Coil Supply Fan 2000 cfm 105.0 OF 3i,Supply Air Ducts 104.8 OF ROOMS 70.0 OF k Return Air Ducts `i 83.4/66.30F M 55.0/53.70F Cooling Coil Supply Fan 2000 cfm 55.0/53.70 -� Supply Air Ducts 55.7 / 54.0 OF 50.6% R.H. ROOMS 74.0 / 61.8 OF �% Return Air Ducts '� EnergyPro 4.4 by EnergySoft • User Number: 5950 Job Number: C07079 Page:22 of 24 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 SYSTEM NAME FLOOR AREA Tenant G __1,2 0 0 ENGINEERING CHECKS 1SYSTEM LOAD II Number of S stems 1 Heating System Output per System 56,000 Total Output (Btuh) 56,000 Output (Btuh/sgft) 46.7 Cooling System Output per System 55,000 Total Output (Btuh) 55,000 Total Output (Tons) 4.6 Total Output (Btuh/sgft) 45.8 Total Output (sgft/Ton) 261.8 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.67 Alrflow (cfm/Ton) 436.4 Outside Air (%) 15.0 Outside Air (cfm/sgft) 0.25 Note: values above given at ARI conditions . 26.0 of Outside '—� 300 cfm 69.8 of 11.0 / 77.6 OF Outside er—y 300 cfm 74.7/62.0 OF 4.4 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 47,900 10,573 21 939 York BHP060 46,429 2,463 34,976 Total Adjusted System Output 46,429 2,463 34,976 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 5 1 Jan 12 am 63.30F ` 105.0 OF Heating Coil Supply Fan 2000 cfm 105.0 of Supply Air Ducts 104.8 of ROOMS 70.0 of �% Return Air Ducts 80.2 / 64.7 of 4 55.0 / 53.8 of User Number: 5950 Cooling Coil Supply Fan 2000 cfm 55.0/53.80 —�j Supply Air Ducts 55.7/54.1OF 50.3% R.H. ROOMS 74.0 / 61.7 OF Return Air Ducts Job Number: C07079 o124 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center - Retail 3 2/28/2008 SYSTEM NAME FLOOR AREA Tenant H 1.500 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 Heating System Output per System 42,000 Total Output (Btuh) 84,000 Output (Btuh/sqft) 56.0 Cooling System Output per System 42,000 Total Output (Btuh) 84,000 Total Output (Tons) 7.0 Total Output (Btuh/sgft) 56.0 Total Output (sgft/Ton) 214.3 Air System CFM per System 1,400 Airflow (cim) 2,800 Airflow (cfm/sgft) 1.87 Alrflow (cfm/Ton) 400.0 Outside Air (%) 13.4 Outside Air (cim/sqft) 0.25 Note: values above given at ARI conditions 26.0 OF ?� Outside Air 375 cfm 74.7 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK ICOILHTG.PEAK CFM I Sensiblel Latent 1. CFM I Sensible 2,082 44,304 6,250 F 614 19,601 0 2,215 980 0 0 375 14,469 7,112 375 19,424 0 0 2,215 980 65,298 13,362 40 985 HVAC EQUIPMENT SELECTION York BHP042 64,374 9,830 52,464 Total Adjusted System Output4,374 9,830 52,464 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 68.2°F rf= 105.0°F Heating Coil 105.0 OF Supply Air Ducts Supply Fan 104.7 OF 2800 cfm ROOMS 75.0 OF k Return Air Ducts 4 COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) I 12.0 / 77.9 OF Outside Air 375 cfm 75.7/62.2 °F 80.6 / 64.6 OF = 55.0 / 53.7 OF 55.0 / 53.7 OF Cooling Coil xf Supply Air Ducts �O Supply Fan 55.7 / 54.0 of 2800 cfm 48.1% R.H. ROOMS 75.0 / 62.0 OF Return Air Ducts EnergyPro 4.4 by EnergySoft User Number: 5950 Job Number: C07079 Paoe:24 of 24 1