Trilogy TR 30023 (Product 1) 2007 Code Update - Title 24TITLE 24 Energy Conservation Compliance Report � MAR 2 0 2008 I U TRILOGY AT LA QUINTA La Quinta, California PRODUCT-1 Prepared For.- SHEA HOMES 60946 Desert Rose La Quinta, CA 92253 Phone: (760) 777-6026 Date :Feb 25th, 2008 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION qaw - t oo-C, � AIR CONDITIONING INC. "Working As Team to Be The Best In Our Industry" Chinh Nguyen, Certified Energy Analyst 1610 N. Maple Street Corona, CA 92880-1760 (800) 700-0799 / (951) 739-9509 fax E-mail.- chinh.nquven(0Dwestpacair.com Table of Contents 11 -Cover Sheet -T-24 Summary report -Plan 4210 - CF-1R Certificate of Compliance - MF-1 R Mandatory Measures Check List - Plan 4210/option Bay 2 - CF-I R Certificate of Compliance - MF-1 R Mandatory Measures Check List - Plan 4210/option Bay 2/Casita - CF-1 R Certificate of Compliance - MF-1R Mandatory Measures Check List - Plan 4510 - CF-1 R / Certificate of Compliance - MF-1 R Mandatory Measures Check List - Plan 4510/Option Bay 2/Study - CF-1 R / Certificate of Compliance - MF-1 R Mandatory Measures Check List - Plan 4510/Option Bay 2/Study/Casita CF-1 R / Certificate of Compliance - MF-1 R Mandatory Measures Check List - Plan 4520 - CF-1R / Certificate of Compliance - MF-1 R Mandatory Measures Check List - Plan 4520/Option Bay 2 - CF-I R / Certificate of Compliance - MF-1 R Mandatory Measures Check List Plan 4520/Option Bay 2/Casita - CF-I R / Certificate of Compliance - MF-1 R Mandatory Measures Check List - Plan 4515 CF-I R / Certificate of Compliance MF-1R Mandatory Measures Check List - Plan 4515/Option Bay - CF-1 R / Certificate of .Compliance MF-1 R Mandatory Measures Check List TITLE-24 SUMMARY REPORT The Following is the requirement to exceed the 2005 Residential Energy Standards (California Code of Regulations, Title 24, Part 6 and the Administrative Regulations, Title 24, Part 1) 15% 1. R-38 Roof Insulation. 2. Radiant Barrier is Required. 3. R-13 Exterior Wall Insulation. 4. Low-e Vinyl Windows & Sliding Doors to be selected by Owner: -Operable Windows with U value of 0.34 & SHGC of 0.30 -Fixed Windows with U value of 0.34 & SHGC of 0.33 -Sliding Glasses Door with U value of 0.34 & SHGC of 0.31 5. R-6.0 Duct Insulation. 6. Gas Furnace with 80% AFUE . 7. Condenser 14.0 SEER With Minimum EER of 11.5 8. TXV Required. 9. 50 Gallons Water Heater to be selected by Owner. 10.Ducts Tested Required. I I.Quality Insulation Installation is Required. SHEA HOMES PRODUCT-1 TRILOGY AT LA QUINTA PLAN -4210 Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-.lR Page 1 Project Title.......... Plan 4210 Standard Date..02/25/08 16:37:26 Project Address........ ******* -------=------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # Westpac Air Conditioning, Inc. I I 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 1 I (951) 739-9501 1 Field Check/ Date 1 Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------- 1 MICROPAS7 v7.10 File-TRI_4210 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387. User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- ---------------------------- ---------------------------- MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) Design Design Margin = = Space Heating.......... 2.05 1.62 0.43 = - Space Cooling.......... 79.88 60.90 18.98 = = Water Heating.......... 14.58 13.23 1.35 = = North Total 96.51 75.75 20.76 = = Space Heating.......... 2.05 1.92 0.13 = - Space Cooling.......... 79.88 61.85 18.03 = = Water Heating.......... 14.58 13.23 1.35 = = East Total 96.51 77.00 19.51 = = Space Heating.......... 2.05 2.28 -0.23 = - Space Cooling.......... 79.88 60.30 19.58 = = Water Heating.......... 14.58 13.23 1.35 = = South Total 96.51 75.81 20.70 = = Space Heating.......... 2.05 1.84 0.21 = - Space Cooling.......... 79.88 60.26 19.62 = = Water Heating.......... 14.58 13.23 1.35 = = West Total 96.51 75.33 21.18 = _ *** Building complies with Computer Performance _ *** HERS Verification Required for Compliance *** _ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4210 Standard Date..02/25/08 16:37:26 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_4210 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 1355 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of .Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 12195 cf 1355 sf 21.5 % of floor area 0.34 Btu/hr-sf-F 0.31 9 ft BUILDING ZONE INFORMATION ------------------------- Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ----- ------------- ----- ------- ---------- Residence 1355 12195 1.00 4.0 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 1 Wall ----- Wood ---- 222 ----- 0.102 ----- 13 ----- 0 --- 180 ---- 90 --- Yes --------- IV.9 A3 ------------ SOUTH 2 Wall Wood 348 0.102 13 0 270 90 Yes IV.9 A3 WEST 3 Wall Wood 133 0.102 13 0 0 90 Yes IV.9 A3 NORTH 4 Wall Wood 350 0.102 13 0 90 90 Yes IV.9 A3 EAST 5 Wall Wood 198 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 6 RoofRad Wood 1355 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 7 Door Wood 20 0.387 0 0 0 90 Yes None Wood Door 8 Door Wood 18 0.387 0 0 0 90 No None Wood Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4210 Standard Date..02/25/08 16:37:26 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_4210 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- PERIMETER LOSSES Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ 9 SlabEdge ------ 152 -------- 0.900 ------- R-0 ----- No --------- None ---------------------- To Outside 10 SlabEdge 24 0.550 R-0 No None TO GARAGE FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ 1 Wind Back (S) ----- 36.0 ----- 0.340 ----- 0.300 --- 180 ---- 90 -------- Standard ------------------------ SGLASSI/Vinyl/Operable W 2 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS2/Vinyl/Sliding G1 3 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS3/Vinyl/Operable W 4 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS4/Vinyl/Operable W 5 Wind Right (W) 12.0 0.340 0.300 270 90 Standard WGLASSI/Vinyl/Operable W 6 Wind Right (W) 6.0 0.340 0.300 270 90 Standard WGLASS2/Vinyl/Operable W 7 Wind Right (W) 5.0 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind 8 Wind Right (W) 12.0 0.340 0.300 270 90 Standard WGLASS4/Vinyl/Operable W 9 Wind Front (N) 5.5 0.340 0.330 0 90 Standard NGLASSI/Vinyl/Fixed Wind 10 Wind Front (N) 12.0 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind 11 Wind Front (N) 3.5 0.340 0.330 0 90 Standard NGLASS3/Vinyl/Fixed Wind 12 Wind Front (N) 15.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W 13 Wind Left (E) 4.0 0.340 0.330 90 90 Standard EGLASSI/Vinyl/Fixed Wind 14 Wind Left (E) 36.0 0.340 0.300 90 90 Standard EGLASS2/Vinyl/Operable W 15 Door Left (E) 24.0 0.340 0.310 90 90 Standard EGLASS3/French Door OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- 1 Window ----- 36.0 ----- 6.00 ------ 6.00 ----- 6.00 ------ 0.50 --------- n/a --------- n/a 2 Door 48.0 6.00 8.00 6.00 0.50 n/a n/a 3 Window 36.0 6.00 6.00 6.00 0.50 n/a n/a 9 Window 5.5 5.50 1.00 5.00 0.50 n/a n/a 10 Window 12.0 2.00 6.00 5.00 0.50 n/a n/a 15 Door 24.0 3.00 8.00 8.00 0.50 n/a n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 Project Title.......... Plan 4210 Standard Date..02/25/08 16:37:26 I MICROPAS7 v7.10 File-TRI_4210 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ Standard Slab 1355 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type ------------ Systems ------- Efficiency EER or TXV Airflow Draw Capacity Furnace 1 ----------- ----- 0.800 AFUE n/a ------------- n/a -------- n/a -------- n/a -------- n/a ACSplit 1 14.00 SEER 11.5 Yes No No No HVAC SIZING Total Sensible Heating Cooling System Load Load Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- Furnace 28375 n/a ACSplit n/a 22040 Orientation of Maximum..... Sizing Location............ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range ............... Verified Design Maximum Cooling Cooling Capacity Capacity (Btu/hr) --------- (Btu/hr) ---------- n/a n/a 27352 n/a Front Facing 90 deg (E) LA QUINTA 26 F 70 F 111 F 75 F 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location ----------- R-value ------- Leakage Area Ducts Furnace Attic R-6 ------- Yes -------- No -------- No ACSplit Attic R-6 Yes No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4210 Standard Date..02/25/08 16:37:26 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_4210 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- WATER HEATING SYSTEMS --------------------- Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6 ------------------------------------------ Project Title.......... Plan 4210 Standard Date..02/25/08 16:37:26 I MICROPAS7 v7.10 File-TRI_4210 Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION -------------------------- redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. Name... Company Address Phone... License. Signed.. Name.... Title... Agency.. Phone... DESIGNER or OWNER Kyle Tibbitts Shea Homes/Trilogy 60946 Desert Rose La Quinta, CA 92253 (76_0) 777-6026 (date) ENFORCEMENT AGENCY Signed.. (date) Name.... Company. Address. Phone... Signed.. DOCUMENTATION AUTHOR Chinh Nguyen Westpac Air Conditioning, Inc. 1610 N. Maple St. Corona, CA 92880 MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 1 Project Title.......... Plan 4210 Standard Date..02/25/08 16:37:26 Project Address......... Documentation Author... Climate Zone.......... Compliance Method..... La Quinta, CA Chinh Nguyen Westpac Air Conditioning, 1610 N. Maple St. Corona, CA 92880 (951) 739-9501 15 MICROPAS7 v7.10 for 2005 Building Permit # Plan Check / Date Field Check/ Date Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_4210 Wth-CTZ15S05 Program -FORM MF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling 150(b): Loose fill insulation manufacturer's labeled R-Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox / b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only j 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF-6R form / 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage / 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 2 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4210 Standard Date..02/25/08 16:37:26 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_4210 Wth-CTZ15S05 Program -FORM MF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES n/a 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value / 3. The following piping is insulated according to Table'150- B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, De- En- sign- force er ment MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4210 Standard Date..02/25/08 16:37:26 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_4210 Wth-CTZ15S05 Program -FORM MF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to sea openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used 2. Building cavities, support platforms for air handlers, an plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to reductions in the cross -sectional area of the ducts 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands _ 4. Exhaust fan systems have back draft or automatic dampers_ 5. Gravity ventilating systems serving conditioned space hav either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protecte as above or painted with a coating that is water retardan and provides shielding from solar radiation that can caus degradation of the material 7. Flexible ducts cannot have porous inner cores _ 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no j electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating L b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES n/a 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic and cause - De- En- sign- force er ment MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R ------------------------------------------------------------------------------- Page 4 ------------------------------------------------------------------------------- Project Title.......... Plan 4210 Standard Date..02/25/08 ------------------------------------------------------------------------------- 16:37:26 ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_4210 Wth-CTZ15S05 Program -FORM MF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ---- ---------- ---------- -------- ----- ----------------------------- ---- and have an output frequency no less than 20 kHz 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) SHEA HOMES PRODUCT-1 TRILOGY AT LA QUINTA PLAN -4210/OPT. BA Y 2 Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 1 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title........... Plan 4210/Option Bay 2 Date..02/25/08 16:39:26 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. 1 1 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 I 1 (951) 739-9501 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 1 MICROPAS7 v7.10 File-T4210OB2 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- ---------------------------- ---------------------------- MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) _----------------------- ---------- Design Design ---------- Margin = = Space Heating.......... 1.99 ---------- 1.55 - 0.44 = = Space Cooling.......... 79.20 60.73 18.47 = = Water Heating.......... 14.40 13.08 1.32 = = North Total 95.59 75.36 20.23 = - Space Heating.......... 1.99 2.00 -0.01 = - Space Cooling.......... 79.20 62.79 16.41 = = Water Heating.......... 14.40 13.08 1.32 = = East Total 95.59 77.87 17.72 = - Space Heating.......... 1.99 2.39 -0.40 = - Space Cooling.......... 79.20 59.58 19.62 = = Water Heating.......... 14.40 13.08 1.32 = = South Total 95.59 75.05 20.54 = = Space Heating.......... 1.99 1.85 0.14 = - Space Cooling.......... 79.20 60.83 18.37 = - Water Heating.......... 14.40 13.08 1.32 = = West Total 95.59 75.76 19.83 = _ *** Building complies with Computer Performance _ *** HERS Verification Required for Compliance *** _ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4210/Option Bay 2 Date..02/25/08 16:39:26 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T4210OB2 Wth-CTZ15S05 Program -FORM CF-1R J User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 1381 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 12429 cf 1381 sf 23.7 % of floor area 0.34 Btu/hr-sf-F 0.31 9 ft BUILDING ZONE INFORMATION Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units, le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ----- ------------- ----- ------- ---------- Residence 1381 12429 1.00 4.0 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 1 Wall ----- Wood ---- 186 ----- 0.102 ----- 13 ----- 0 --- 180 ---- 90 --- Yes --------- IV.9 A3 -------------- SOUTH 2 Wall Wood 348 0.102 13 0 270 90 Yes IV.9 A3 WEST 3 Wall Wood 133 0.102 13 0 0 90 Yes IV.9 A3 NORTH 4 Wall Wood 350 0.102 13 0 90 90 Yes IV.9 A3 EAST 5 Wall Wood 198 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 6 RoofRad Wood 1355 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 7 Door Wood 20 0.387 0 0 0 90 Yes None Wood Door 8 Door Wood 18 0.387 0 0 0 90 No None Wood Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4210/Option Bay 2 Date..02/25/08 16:39:26 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4210OB2 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- PERIMETER LOSSES ---------------- Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ 9 SlabEdge ------ 152 -------- 0.900 ------- R-0 ----- No --------- None ---------------------- To Outside 10 SlabEdge 24 0.550 R-0 No None TO GARAGE FENESTRATION SURFACES Exterior Area U- Act Shade Orientation ------------------ (sf) ----- factor ----- SHGC ----- Azm --- Tilt ---- Type -------- Location/Comments 1 Wind Back (S) 36.0 0.340 0.300 180 90 Standard ------------------------ SGLASSI/Vinyl/Operable W 2 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS2/Vinyl/Sliding Gl 3 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS3/Vinyl/Operable W 4 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS4/Vinyl/Operable W 5 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASSS/French Door 6 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS6/Vinyl/Operable W ,7 Wind Right (W) 12.0 0.340 0.300 270 .90 Standard WGLASSI/Vinyl/Operable W 8 Wind Right (W) 6.0 0.340 0.300 270 90 Standard WGLASS2/Vinyl/Operable W 9 Wind Right (W) 5.0 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind 10 Wind Right (W) 12.0 0.340 0.300 270 90 Standard WGLASS4/Vinyl/Operable W 11 Wind Front (N) 5.5 0.340 0.330 0 90 Standard NGLASSI/Vinyl/Fixed Wind 12 Wind Front (N) 12.0 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind 13 Wind Front (N) 3.5 0.340 0.330 0 90 Standard NGLASS3/Vinyl/Fixed Wind 14 Wind Front (N) 15.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W 15 Wind Left (E) 4.0 0.340 0.330 90 90 Standard EGLASSI/Vinyl/Fixed Wind 16 Wind Left (E) 36.0 0.340 0.300 90 90 Standard EGLASS2/Vinyl/Operable W 17 Door Left (E) 24.0 0.340 0.310 90 90 Standard SGLASS3/French Door OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface ----------- (sf) ----- Width Height Depth Height Extension Extension 1 Window 36.0 ----- 6.00 ------ 6.00 ----- 6.00 ------ 0.50 --------- n/a --------- n/a 2 Door. 48.0 6.00 8.00 6.00 0.50 n/a n/a 3 Window 36.0 6.00 6.00 6.00 0.50 n/a n/a 4 Window 12.0 2.00 6.00 3.00 0.50 n/a n/a 6 Window 12.0 2.00 6.00 3.00 0.50 n/a n/a 7 Window 12.0 2.00 6.00 3.00 0.50 n/a n/a 8 Window 6.0 2.00 3.00 2.00 0.50 n/a n/a 9 Window 5.0 5.00 1.00. 2.00 0.50 n/a n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 Project Title.......... Plan 4210/Option Bay 2 Date..02/25/08 16:39:26 I MICROPAS7 v7.10 File-T4210OB2 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface --=-------- (sf) Width Height Depth Height Extension Extension 11 Window ----- 5.5 ----- 5.50 ------ 1.00 ----- 5.00 ------ 0.50 --------- n/a --------- n/a 12 Window 12.0 2.00 6.00 5.00 0.50 n/a n/a 16 Window 36.0 6.00 6.00 3.00 0.50 n/a n/a 17 Door 24.0 3.00 8.00 .8.00 0.50 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ Standard Slab 1381 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type ------------ Systems Efficiency EER or TXV Airflow Draw Capacity Furnace ------- 1 ----------- ----- 0.800 AFUE n/a ------------- n/a -------- n/a -------- n/a -------- n/a ACSplit 1 14.00 SEER 11.5 Yes No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) Furnace 28914 n/a n/a ---------- n/a ACSplit n/a 23305 28922 n/a Orientation of Maximum..... Sizing Location............ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range ............... Front Facing 90 deg (E) LA QUINTA 26 F 70 F 111 F 75 F 34 F CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4210/Option Bay 2 Date..02/25/08 16:39:26 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4210OB2 Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R-value Leakage Area Ducts ------------------------------------------------------- Furnace Attic R-6 Yes No No ACSplit Attic R-6 Yes No No WATER HEATING SYSTEMS --------------------- Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications., and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4210/Option Bay 2 Date..02/25/08 16:39:26 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4210OB2 Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION -------------------------- This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7 Project Title.......... Plan 4210/Option Bay 2 Date..02/25/08 16:39:26 I MICROPAS7 v7.10 File-T421OOB2 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER Name.... Kyle Tibbitts Company. Shea Homes/Trilogy Address. 60946 Desert Rose La Quinta, CA 92253 Phone... (760) 777-6026 License. ?(o Z-Z9%r M 0 VE, � 71 M � � E ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Chinh Nguyen Company. Westpac Air Conditioning, Inc. Address. 1610 N. Maple St. Corona, CA 92880 Phone... (951) 739-9501 Signed.. (dat / MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 1 ----------------------- ----------------------- Project Title.......... Project Address........ ------------------------------------------------------- ------------------------------------------------------- Plan 4210/Option Bay 2 Date..02/25/08 16:39:26 La Quinta, CA Documentation Author... Chinh Nguyen Westpac Air Conditioning, 1610 N. Maple St. Corona, CA 92880 (951) 739-9501 Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4210OB2 Wth-CTZ15S05 Program -FORM MF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- ******* --------------------- *v7.10* I I ******* I Building Permit # I Inc. I I Plan Check / Date I I I I Field Check/ Date I Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling 150(b): Loose fill insulation manufacturer's labeled R-Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified'in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF-6R form 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL _ MF-lR Page 2 ------------- Project Title.......... Plan 4210/Option Bay 2 Date..02/25/08 16:39:26 I MICROPAS7 v7.10 File-T4210OB2 Wth-CTZ15S05 Program -FORM MF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I --------=---------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES n/a 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A �L 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, De- En- sign- force er ment wMe MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 3 Project Title.......... Plan 4210/Option Bay 2 Date..02/25/08 16:39:26 MICROPAS7 v7.10 File-T4210OB2 Wth-CTZ15S05 Program -FORM MF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands - 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light.(Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 4 Project Title.......... Plan 4210/Option Bay 2 Date..02/25/08 16:39:26 MICROPAS7 v7.10 File-T4210OB2 Wth-CTZ15S05 Program -FORM MF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- and have an output frequency no less than 20 kHz 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast / 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires - 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option / 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential, buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) SHEA HOMES PRODUCT-1 TRILOGY AT LA QUINTA PLAN -4210/0PT. BA Y 21CASITA Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1 Project Title.......... Plan 4210/Opt.Bay2/Casita Date..02/25/08 16:40:20 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I 1 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 I (951) 739-9501 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. I MICROPAS7 v7.10 File-T4210CST Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- = _ MICROPAS7 ENERGY USE SUMMARY = = Energy ---------------------------- Use Standard - Proposed Compliance = _ (kTDV/sf-yr) _----------------------- ---------- Design Design -------------------- Margin = - = Space Heating.......... 2.46 2.42 0.04 = = Space Cooling.......... 81.21 63.48 17.73 = Water Heating.......... 12.94 11.81 1.13 = = North Total 96.61 77.71 18.90 = = Space Heating.......... 2.46 2.73 -0.27 = = Space Cooling.......... 81.21 65.09 16.12 = - Water Heating.......... 12.94 11.81 1.13 = = East Total 96.61 79.63 16.98 = - Space Heating.......... 2.46 3.12 -0.66 = - Space Cooling.......... 81.21 63.19 18.02 = - Water Heating.......... 12.94 .11.81 1.13 = = South Total 96.61 78.12 18.49 = = Space Heating.......... 2.46 2.60 -0.14 = = Space Cooling.......... 81.21 63.91 17.30 = - Water _ Heating 12.94 -------- 11.81 1.13 = - = West Total 96.61 ---------------- 78.32 18.29 = _ *** Building complies with Computer Performance _ *** HERS Verification Required for Compliance *** _ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2 Project Title.......... Plan 4210/Opt.Bay2/Casita Date..02/25/08 16:40:20 MICROPAS7 v7.10 File-T4210CST Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 1636 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 2 Conditioned Volume......... 14724 cf Slab -On -Grade Area......... 1636 sf Glazing Percentage......... 23 % of floor area Average Glazing U-factor... 0.34 Btu/hr-sf-F Average Glazing SHGC....... 0.31 Average Ceiling Height..... 9 ft BUILDING ZONE INFORMATION ------------------------- Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type ------=------- (sf) (cf) Units le ----- ------ ----- ----- ioned Type (ft) (sf) Housewrap ------------- ----- ------- ---------- HOUSE Residence 1381 12429 0.80 3.2 Yes Setback 2.0 Standard No CASITA Residence 255 2295 0.20 0.4 Yes Setback 2.0 Standard No OPAQUE SURFACES --------------- U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface ------------ Type (sf) or R-val R-val Azm Tilt Reference Comments HOUSE ----- ---- ----- ----- ----- --- ---- --- --------- -------------- 1 Wall Wood 222 0.102 13 0 180 90 Yes IV.9 A3 SOUTH 3 Wall Wood 348 0.102 13 0 270 90 Yes IV.9 A3 WEST 5 Wall Wood 133 0.102 13 0 0 90 Yes IV.9 A3 NORTH 7 Wall Wood 350 0.102 13 0 90 90 Yes IV.9 A3 EAST 9 Wall Wood 198 0.102 1.3 0 0 90 No IV.9 A3 GARAGE WALL 10 RoofRad Wood 1381 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 12 Door Wood 20 0.387 0 0 0 90 Yes None Wood Door 13 Door Wood 18 0.387 0 0 0 90 No None Wood Door CASITA 2 Wall Wood 105 0.102 13 0 180 90 Yes IV.9 A3 SOUTH CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4210/Opt.Bay2/Casita Date..02/25/08 16:40:20 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4210CST Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 4 Wall ----- Wood ---- 129 ----- 0.102 ----- 13 ----- 0 --- 270 ---- 90 --- Yes --------- IV.9 A3 -------------- WEST 6 Wall Wood 123 0.102 13 0 0 90 Yes IV.9 A3 NORTH 8 Wall Wood 135 0.102 13 0 90 90 Yes IV.9 A3 EAST 11 RoofRad Wood 255 0.025 38 0 n/a 0 Yes IV.1 A18 Attic PERIMETER LOSSES Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ --------------------- -------------- ---------------------- HOUSE 14 SlabEdge 152 0.900 R-0 No None To Outside 16 SlabEdge 24 0.550 R-0 No None TO GARAGE CASITA •15 SlabEdge 64 0.900 R-0 No None To Outside FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ HOUSE 1 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASSI/Vinyl/Operable W 2 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS2/French Door 3 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS3/Vinyl/Operable W 4 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS4/Vinyl/Operable W 6 Wind Right (W) 12.0 0.340 0.300 270 90 Standard WGLASS1/Vinyl/Operable W 7 Wind Right (W) 6.0 0.340 0.300 270 90 Standard WGLASS2/Vinyl/Operable W 8 Wind Right (W) 5.0 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind 9 Door Right (W) 12.0 0.340 0.310 270 90 Standard WGLASS4/Vinyl/Sliding G1 11 Wind Front (N) 5.5 0.340 0.330 0 90 Standard NGLASSI/Vinyl/Fixed Wind 12 Wind Front (N) 12.0 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind 13 Wind Front (N) 4.0 0.340 0.330 0 90 Standard NGLASS3/Vinyl/Fixed Wind 14 Wind Front (N) 15.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W 17 Wind Left (E) 4.0 0.340 0.330 90 90 Standard EGLASSI/Vinyl/Fixed Wind 18 Wind Left (E) 36.0 0.340 0.300 90 90 Standard EGLASS2/Vinyl/Operable W 19 Door Left (E) 24.0 0.340 0.310 90 90 Standard EGLASS3/French Door CASITA 5 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS5/Vinyl/Sliding G1 10 Wind Right (W) 6.0 0.340 0.300 270 90 Standard WGLASSS/Vinyl/Operable W 15 Wind Front (N) 15.0 0.340 0.300 0 90 Standard NGLASS5/Vinyl/Operable W 16 Wind Front (N) 15.0 0.340 0.330 0 90 Standard NGLASS6/Vinyl/Fixed Wind CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4210/Opt.Bay2/Casita Date..02/25/08 16:40:20 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T4210CST Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- HOUSE ----- ----- ------ ----- ------ --------- --------- 1 Window 36.0 6.00 6.00 6.00 0.50 n/a n/a 2 Door 48.0 6.00 8.00 6.00 0.50 n/a n/a 3 Window 36.0 6.00 6.00 6.00 0.50 n/a n/a 11 Window 5.5 5.50 1.00 5.00 0.50 n/a n/a 12 Window 12.0 2.00 6.00 5.00 0.50 n/a n/a 13 Window 4.0 2.00 2.00 8.00 0.50 n/a n/a 14 Window 15.0 3.00 5.00 8.00 0.50 n/a n/a 19 Door 24.0 3.00 8.00 8.00 0.50 n/a n/a CASITA 5 Door 48.0 6.00 8.00 6.00 0.50 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ HOUSE Standard Slab 1381 CASITA Standard Slab 255 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type Systems Efficiency EER or TXV Airflow Draw Capacity ------------ HOUSE ------- ----------- ----- ------------- -------- -------- -------- Furnace 0.8 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 0.8 14.00 SEER 11.5 Yes No No No CASITA HPSplit 0.2 7.70 HSPF n/a n/a n/a n/a n/a HPSplit 0.2 14.00 SEER 11.5 Yes No No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5 Project Title.......... Plan 4210/Opt.Bay2/Casita Date..02/25/08 16:40:20 MICROPAS7 v7.10 File-T4210CST Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr) ----------------------------------------------------- HOUSE Furnace 28538 n/a n/a n/a ACSplit n/a 21186 26291 n/a CASITA HPSplit 8593 n/a n/a n/a HPSplit n/a 6053 7512 n/a ----------------------------------------------------- Total 37131 27239 33804 n/a Orientation of Maximum..... Front Facing 90 deg (E) Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location ----------- R-value Leakage Area Ducts HOUSE ------- ------- -------- --------- Furnace Attic R-6 Yes No No ACSplit Attic R-6 Yes No No CASITA HPSplit Attic R-6 Yes No No HPSplit Attic R-6 Yes No No WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6 Project Title.......... Plan 4210/Opt.Bay2/Casita Date..02/25/08 16:40:20 I MICROPAS7 v7.10 File-T4210CST Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7 Project Title.......... Plan 4210/Opt.Bay2/Casita Date..02/25/08 16:40:20 I MICROPAS7 v7.10 File-T4210CST Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- REMARKS COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... Kyle Tibbitts Name.... Chinh Nguyen Company. Shea Homes/Trilogy Company. Westpac Air Conditioning, Inc. Address. 60946 Desert Rose Address. 1610 N. Maple St. La Quinta, CA 92253 Corona, CA 92880 Phone... (760) 777-6026 Phone... (951) 39-9501 License.oZZgj Signed.. Signed.. V (date) (date ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) MANDATORY MEASURES CHECKLIST.: RESIDENTIAL MF-1R Page 1 Project Title.......... Plan 4210/Opt.Bay2/Casita Date..02/25/08 16:40:20 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. 1 1 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 1 1 (951) 739-9501 1 Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. I MICROPAS7 v7.10 File-T4210CST Wth-CTZ15S05 Program -FORM MF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling 150(b): Loose fill insulation manufacturer's labeled R-Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox V b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only T 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.30, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality . standards. Indicate type and include CF-6R form 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned / spaces designed to limit air leakage J 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 2 ------------------- Project Title.......... Plan 4210/Opt.Bay2/Casita Date..02/25/08 16:40:20 I MICROPAS7 v7.10 File-T4210CST Wth-CTZ15S05 Program -FORM MF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES n/a 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A __Z 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, De- En- sign- force er ment WA MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 3 Project Title.......... Plan 4210/Opt.Bay2/Casita Date..02/25/08 16:40:20 MICROPAS7 v7.10 File-T4210CST Wth-CTZ15S05 Program -FORM MF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used 2. Building cavities, support platforms for air handlers, and - plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts i 1 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands / 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light j 2. System is installed with: a. At least 36 inches of pipe between filter and heater f f 1 1- or uture so ar eating j b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch 115: Gas -fired central furnaces, pool heaters, spa heaters or� household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 4 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4210/Opt.Bay2/Casita Date..02/25/08 16:40:20 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T4210CST Wth-CTZ15S05 Program -FORM MF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------ ----- and have an output frequency no less than 20 kHz 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4:.Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air / tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) _� SHEA HOMES PRODUCT-1 TRILOGY AT LA QUINTA PLAN -4510 Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4510 Standard Date..02/25/08 16:41:03 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac.Air Conditioning, Inc. I I 1610 N. Maple St. ( Plan Check / Date I Corona, CA 92880 I (951) 739-9501 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_4510 Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- ---------------------------- ---------------------------- MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance _ _ (kTDV/sf-yr) _----------------------- ---------- Design Design -------------------- Margin = - = Space Heating.......... 2.09 1.75 0.34 = = Space Cooling.......... 78.56 57.44 21.12 = = Water - Heating.......... 13.39 12.20 1.19 = - = North Total -------- 94.04 ---------------- 71.39 22.65 = = Space Heating.......... 2.09 1.95 0.14 = - Space Cooling.......... 78.56 59.92 18.64 = = Water Heating.......... 13.39 12.20 1.19 = = East Total 94.04 74.07 19.97 = = Space Heating.......... 2.09 2.39 -0.30 = - Space Cooling.......... 78.56 57.90 20.66 = = Water Heating.......... 13.39 12.20 1.19 = = South Total 94.04 72.49 21.55 = - Space Heating.......... 2.09 2.17 -0.08 = - Space Cooling.......... 78.56 58.30 20.26 = = Water Heating.......... 13.39 12.20 1.19 = = West Total 94.04 72.67 21.37 = _ *** Building complies with Computer Performance _ *** HERS Verification ----------------------------------------------------------------- ----------------------------------------------------------------- Required for Compliance CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 Project Title.......... Plan 4510 Standard Date..02/25/08 16:41:03 MICROPAS7 v7.10 File-TRI 4510 Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 1547 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 13923 cf 1547 sf 21.3 % of floor area 0.34 Btu/hr-sf-F 0.31 9 ft BUILDING ZONE INFORMATION Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ----- ------------- ----- ------- ---------- Residence 1547 13923 1.00 4.0 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 1 Wall ----- Wood ---- 237 ----- 0.102 ----- 13 ----- 0 --- 180 ---- 90 --- Yes --------- IV.9 A3 -------------- SOUTH 2 Wall Wood 298 0.102 13 0 270 90 Yes IV.9 A3 WEST 3 Wall Wood 136 0.102 13 0 0 90 Yes IV.9 A3 NORTH 4 Wall Wood 402 0.102 13 0 90 90 Yes IV.9 A3 EAST 5 Wall Wood 333 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 6 RoofRad Wood 1547 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 7 Door Wood 20 0.387 0 0 0 90 Yes None Wood Door 8 Door Wood 18 0.387 0 0 0 90 No None Wood Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4510 Standard Date..02/25/08 16:41:03 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_4510 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- PERIMETER LOSSES ---------------- Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ 9 SlabEdge ------ 158 -------- 0.900 ------- R-0 ----- No --------- None ---------------------- To Outside 10 SlabEdge 39 0.550 R-0 No None TO GARAGE FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ 1 Wind Back (S) ----- 15.0 ----- 0.340 ----- 0.300 --- 180 ---- 90 -------- Standard ------------------------ SGLASSI/Vinyl/Operable W 2 Wind Back (S) 30.0 0.340 0.330 180 90 Standard SGLASS2/Vinyl/Fixed Wind 3 Wind Back (S) 15.0 0.340 0.300 180 90 Standard SGLASS3/Vinyl/Operable W 4 Door Back (S) 72.0 0.340 0.310 180 90 Standard SGLASS4/Vinyl/Sliding Gl 5 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS5/Vinyl/Operable W 6 Wind Right (W) 12.0 0.340 0.300 270 90 Standard WGLASSI/Vinyl/Operable W 17 Wind Right (W) 5.0 0.340 0.330 270 90 Standard WGLASS2/Vinyl/Fixed Wind 8 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASSI/Vinyl/Operable W 9 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS2/Vinyl/Operable W 10 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS3/Vinyl/Operable W 11 Wind Front (N) 6.5 0.340 0.330 0 90 Standard NGLASS4/Vinyl/Fixed Wind 12 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W 13 Wind Left (E.) 18.0 0.340 0.300 90 90 Standard EGLASS2/Vinyl/Operable W 14 Door Left (E) 48.0 0.340 0.310 90 90 Standard EGLASS3/Vinyl/Sliding Gl OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- 1 Window ----- 15.0 ----- 2.50 ------ 6.00 ----- 6.00 ------ 0.50 --------- n/a --------- n/a 2 Window 30.0 5.00 6.00 6.00 0.50 n/a n/a 3 Window 15.0 2.50 6.00 6.00 0.50 n/a n/a 4 Door 72.0 9.00 8.00 6.00 0.50 n/a n/a 10 Window 18.0 3.00 6.00 6.00 0.50 n/a n/a 11 Window 6.5 6.50 0.83 6.00 0.50 n/a n/a 13 Window 18.0 3.00 6.00 6.00 0.50 n/a n/a 14 Door 48.0 6.00 8.00 6.00 1.00 n/a n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4510 Standard Date..02/25/08 16:41:03 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_4510 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ Standard Slab 1547 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type Systems Efficiency EER or TXV Airflow Draw Capacity ------------ Furnace ------- 1 ----------- ----- ------------- 0.800 AFUE n/a n/a -------- n/a -------- n/a -------- n/a ACSplit 1 14.00 SEER 11.5 Yes No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) Furnace 31732 n/a n/a ---------- n/a ACSplit n/a 25183 31252 n/a Orientation of Maximum..... Front Facing 90 deg (E) Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location ----------- R-value Leakage Area Ducts Furnace Attic -------------- R-6 Yes -------- No --------- No ACSplit Attic R-6 Yes No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5 Project Title.......... Plan 4510 Standard Date..02/25/08 16:41:03 MICROPAS7 v7.10 File-TRI_4510 Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans,:*** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 6 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4510 Standard Date..02/25/08 16:41:03 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI.4510 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION -------------------------- redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER Name.... Kyle Tibbitts Company. Shea Homes/Trilogy Address. 60946 Desert Rose La Quinta, CA 92253 Phone... (760) 777-6026 License. '�'bZZ.QS Signed.. v y bg (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Chinh Nguyen Company. Westpac Air Conditioning, Address. 1610 N. Maple St. Corona, CA 92880 Phone... (951) 3,39-9501 Inc. Signed.. (/ (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL ------------------------------------------------------------------------------- MF-lR Page 1 ------------------------------------------------------------------------------- Project Title.......... Plan 4510 Standard Date..02/25/08 16:41:03 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I I 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 1 1 (951) 739-9501 1 Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... -----------------------------------------------------------------------------=- MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_4510 Wth-CTZ15S05 Program -FORM MF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta ------------------------------------------------------------------------------- P-1 I Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling- 150(b): Loose fill insulation manufacturer's labeled R-Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors - or equivalent U-factor _ 150(e): Installation of Fireplaces, Decorative Gas Appliances - and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed _ 150(f): Air retarding wrap installed to comply with Sec. 151 _ meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only - 150(1): Slab edge insulation - water absorption rate for the - insulation material without facings no greater than 0.30, water vapor permeance rate no greater than 2.0 perm/inch z 118: Insulation specified or installed meets insulation quality - standards. Indicate type and include CF-6R form 116-17: Fenestration Products, Exterior Doors and Infiltratior/ _ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 2 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4510 Standard Date..02/25/08 16:41:03 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_4510 Wth-CTZ15S05 Program -FORM MF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En- sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi,/ meet requirements of Table 123-A 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, y� �L MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4510 Standard Date..02/25/08 16:41:03 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_4510 Wth-CTZ15S05 Program -FORM MF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch / 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria / RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 4 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4510 Standard Date..02/25/08 ------------------------------------------------------------------------------- 16:41:03 ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI 4510 Wth-CTZ15S05 Program -FORM MF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- and have an output frequency no less than 20 kHz 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy, luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 15'0(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall / have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) SHEA HOMES PRODUCT-1 TRILOGY AT LA QUINTA PLAN -4510/OPT. BA Y 2/STUD Y Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 1 Projec t Title.......... Plan 4510/Opt Bay 2/Study Date..02/25/08 16:41:54 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # Westpac Air Conditioning, Inc. I I 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 I I (951) 739-9501 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. I MICROPAS7 v7.10 File-T4510OB2 Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- = _ MICROPAS7 ENERGY USE SUMMARY = ---------------------------- = Energy Use Standard - Proposed Compliance = _ (kTDV/sf-yr) _----------------------- ---------- Design Design -------------------- Margin = - - Space Heating.......... 2.05 1.83 0.22 = - Space Cooling.......... 77.97 60.19 17.78 = = Water Heating.......... 13.26 12.09 1.17 = = North Total 93.28 74.11 19.17 = = Space Heating.......... 2.05 2.00 0.05 = - Space Cooling.......... 77.97 62.28 15.69 = - Water Heating.......... 13.26 12.09 1.17 = = East Total 93.28 76.37 16.91 = = Space Heating.......... 2.05 2.57 -0.52 = - Space Cooling.......... 77.97 60.82 17.15 = - Water Heating.......... 13.26 12.09 1.17 = = South Total 93.28 75.48 17.80 = = Space Heating.......... 2.05 2.33 -0.28 = = Space Cooling.......... 77.97 60.38 17.59 = = Water _ Heating.......... 13.26 12.09 1.17 = = West Total -------- 93.28 ---------------- 74.80 - 18.48 = _ *** Building complies with Computer Performance _ *** HERS Verification Required for Compliance *** _ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4510/Opt Bay 2/Study Date..02/25/08 16:41:54 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T4510OB2 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 1573 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 14157 cf 1573 sf 26.7 o of floor area 0.34 Btu/hr-sf-F 0.31 9 ft BUILDING ZONE INFORMATION ------------------------- Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap ------ ------ ----- ------ ----- ----- ------------- ----- ------- ---------- Residence 1573 14157 1.00 4.0 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 1 Wall --=-- Wood ---- 201 ----- 0.102 ----- 13 ----- 0 --- 180 ---- 90 --- Yes --------- IV.9 A3 -------------- SOUTH 2 Wall Wood 298 0.102 13 0 270 90 Yes IV.9 A3 WEST 3 Wall Wood 136 0.102 13 0 0 90 Yes IV.9 A3 NORTH 4 Wall Wood 348 0.102 13 0 90 90 Yes IV.9 A3 EAST 5 Wall Wood 333 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 6 RoofRad Wood 1547 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 7 Door Wood 20 0.387 0 0 0 90 Yes None Wood Door 8 Door Wood 18 0.387 0 0 0 90 No None Wood Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4510/Opt Bay 2/Study Date..02/25/08 16:41:54 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T4510OB2 Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- PERIMETER LOSSES Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ 9 SlabEdge ------ 158 -------- 0.900 ------- R-0 ----- No --------- None ---------------------- To Outside 10 SlabEdge 39 0.550 R-0 No None TO GARAGE FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ 1 Wind Back (S) ----- 15.0 ----- 0.340 ----- 0.300 --- 180 ---- 90 -------- Standard ------------------------ SGLASSI/Vinyl/Operable W 2 Wind Back (S) 30.0 0.340 0.330 180 90 Standard SGLASS2/Vinyl/Fixed Wind 3 Wind Back (S) 15.0 0.340 0.300 180 90 Standard SGLASS3/Vinyl/Operable W 4 Door Back (S) 72.0 0.340 0.310 180 90 Standard SGLASS4/Vinyl/Sliding G1 5 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS5/Vinyl/Operable W 6 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS6/French Door 7 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS7/Vinyl/Operable W 8 Wind Right (W) 12.0 0.340 0.300 270 90 Standard WGLASSI/Vinyl/Operable W 9 Wind Right (W) 5.0 0.340 0.330 270 90 Standard WGLASS2/Vinyl/Fixed Wind 10 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASSI/Vinyl/Operable W 11 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS2/Vinyl/Operable W 12 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS3/Vinyl/Operable W 13 Wind Front (N) 6.5 0.340 0.330 0 90 Standard NGLASS4/Vinyl/Fixed Wind 14 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W 15 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASS2/Vinyl/Operable W 16 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASS3/Vinyl/Operable W 17 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W 18 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASS5/Vinyl/Operable W 19 Door Left (E) 48.0 0.340 0.310 90 90 Standard EGLASS6/Vinyl/Sliding G1 OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface ----------- (sf) ----- Width ----- Height ------ Depth ----- Height ------ Extension --------- Extension --------- 1 Window 15.0 2.50 6.00 8.00 0.25 n/a n/a 2 Window 30.0 5.00 6.00 8.00 0.50 n/a n/a 3 Window 15.0 2.50 6.00 8.00 0.25 n/a n/a 4 Door 72.0 9.00 8.00 8.00 0.25 n/a n/a 5 Window 12.0 2.00 6.00 2.50 0.20 n/a n/a 7 Window 12.0 2.00 6.00 2.50 0.20 n/a n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 Project Title.......... Plan 4510/Opt Bay 2/Study Date..02/25/08 16:41:54 I MICROPAS7 v7.10 File-T4510OB2 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- 12 Window ----- 18.0 ----- 3.00 ------ 6.00 ----- 8.00 ------ 0.25 --------- n/a --------- n/a 13 Window 6.5 6.50 0.83 8.00 0.50 n/a n/a 14 Window 18.0 3.00 6.00 2.00 0.50 n/a n/a 15 Window 18.0 3.00 6.00 2.00 0.50 n/a n/a 16 Window 18.0 3.00 6.00 2.00 0.50 n/a n/a 17 Window 18.0 3.00 6.00 2.00 0.50 n/a n/a 18 Window 18.0 3.00 6.00 8.00 0.25 n/a n/a 19 Door 48.0 6.00 8.00 8.00 0.25 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ Standard Slab 1573 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type ------------ Systems Efficiency EER or TXV Airflow Draw Capacity Furnace ------- 1 ----------- ----- ------------- 0.800 AFUE n/a n/a -------- n/a -------- n/a -------- n/a ACSplit 1 14.00 SEER 11.5 Yes No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) Furnace 32910 n/a n/a ---------- n/a ACSplit n/a 26600 33010 n/a Orientation of Maximum..... Front Facing 90 deg (E) Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5 Project Title.......... Plan 4510/Opt Bay 2/Study Date..02/25/08 16:41:54 --------------- I MICROPAS7 v7.10 File-T4510OB2 Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R-value Leakage Area Ducts ------------------------------------------------------- Furnace Attic R-6 Yes No No ACSplit Attic R-6 Yes No No WATER HEATING SYSTEMS --------------------- Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 6 Project Title.......... Plan 4510/Opt Bay 2/Study Date..02/25/08 16:41:54 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4510OB2 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION -------------------------- *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 7 ------------------------------------------------------------------------------- Project Title.......... Plan 4510/Opt Bay 2/Study Date..02/25/08 16:41:54 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4510OB2 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... Kyle Tibbitts Name.... Chinh Nguyen Company. Shea Homes/Trilogy Company. Westpac Air Conditioning, Inc. Address. 60946 Desert Rose Address. 1610 N. Maple St. La Quinta, CA 92253 Corona, CA 92880 Phone... (760) 777-6026 Phone... (951) 739-9501 License. q( ZZgS Signed.. j/ � 3 - '7'""9 Signed.. 2 /mod V (date) r (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 1 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4510/Opt Bay 2/Study Date..02/25/08 16:41:54 Project Address...... La Quinta, CA Documentation Author... Chinh Nguyen Westpac Air Conditioning, 1610 N. Maple St. Corona, CA 92880 (951) 739-9501 ******* --------------------- *v7.10* I I ******* I Building Permit # I Inc. I I I Plan Check / Date I I I I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4510OB2 Wth-CTZ15S05 Program -FORM MF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling & -30 / x 150(b): Loose fill insulation manufacturer's labeled R-Value. *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed / 150.(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF-6R form —� 116-17: Fenestration Products, Exterior Doors and Infiltrationf Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 2 Project Title.......... Plan 4510/Opt Bay 2/Study Date..02/25/08 16:41:54 ---------- I MICROPAS7 v7.10 File-T4510OB2 Wth-CTZ15S05 Program -FORM MF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES n/a 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi/ meet requirements of Table 123-A 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space 7. Solar water -heating systems/collectors are certified by the , Solar Rating and Certification Corporation -sL/ *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, i De- En- sign- force er ment l IZ MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4510/Opt Bay 2/Study Date..02/25/08 16:41:54 ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4510OB2 Wth-CTZ15S05 Program -FORM MF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used T 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts / 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material —� 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot.< 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 4 Project Title.......... Plan 4510/Opt Bay 2/Study Date..02/25/08 16:41:54 I MICROPAS7 v7.10 File-T4510OB2 Wth-CTZ15S05 Program -FORM MF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La ------------------------------------------------------------------------------- Quinta P-1 I and have an output frequency no less than 20 kHz 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located .other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) y� SHEA HOMES PRODUCT-1 TRILOGY AT LA QUINTA PLAN -4510/OPT. BAY 2/STUDYICA,SITA Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 F CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 1 Project Title.......... P14510/OptB 2/Stdy/Casita Date..02/25/08 16:42:47 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I I 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 I I (951) 739-9501 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. - ---------------------------------- I MICROPAS7 v7.10 File-T 4510C2 Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- = MICROPAS7 ENERGY USE SUMMARY = = Energy ---------------------------- Use Standard Proposed Compliance = _ (kTDV/sf-yr) _----------------------- ---------- Design Design -------------------- Margin = - - Space Heating.......... 2.29 2.11 0.18 = - Space Cooling.......... 78.45 61.11 17.34 = = Water Heating.......... 12.14 11.12 1.02 = = North Total 92.88 74.34 18.54 = = Space Heating.......... 2.29 2.14 0.15 = - Space Cooling.......... 78.45 62.54 15.91 = - Water _ Heating.......... 12.14 11.12 1.02 = = East Total -------- 92.88 ---------------- 75.80 - 17.08 = = Space Heating.......... 2.29 2.86 -0.57 = = Space Cooling.......... 78.45 62.69 15.76 = - Water Heating 12.14 11.12 1.02 = = South Total 92.88 76.67 16.21 = = Space Heating.......... 2.29 2.64 -0.35 = = Space Cooling.......... 78.45 60.47 17.98 = - Water _ Heating 12.14 11.12 1.02 = = West Total -------- 92.88 ---------------- 74.23 - 18.65 = _ *** Building complies with Computer Performance _ *** HERS Verification Required for Compliance *** _ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2 Project Title.......... P14510/OptB 2/Stdy/Casita Date..02/25/08 16:42:47 I MICROPAS7 v7.10 File-T_4510C2 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- HERS Verification.......... Required Conditioned Floor Area..... 1822 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 2 Conditioned Volume......... 16398 cf Slab -On -Grade Area......... 1822 sf Glazing Percentage......... 24.3 % of floor area Average Glazing U-factor... 0.34 Btu/hr-sf-F Average Glazing SHGC....... 0.31 Average Ceiling Height..... 9 ft BUILDING ZONE INFORMATION ------------------------- Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type -------------- (sf) (cf) Units le ----- ------ ----- ----- ioned Type (ft) (sf) Housewrap ------------- HOUSE ----- ------- ---------- Residence 1573 14157 0.80 3.2 Yes Setback 2.0 Standard No CASITA Residence 249 2241 0.20 0.8 Yes Setback 2.0 Standard No OPAQUE SURFACES --------------- U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface ------------ Type (sf) or R-val R-val Azm Tilt Reference Comments HOUSE ----- ---- ----- ----- ----- --- ---- --- --------- -------------- 1 Wall Wood 201 0.102 13 0 180 90 Yes IV.9 A3 SOUTH 2 Wall Wood 298 0.102 13 0 270 90 Yes IV.9 A3 WEST 4 Wall Wood 172 0.102 13 0 0 90 Yes IV.9 A3 NORTH 6 Wall Wood 348 0.102 13 0 90 90 Yes IV.9 A3 EAST 8 Wall Wood 333 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 9 RoofRad Wood 1547 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 11 Door Wood 20 0.387 0 0 0 90 Yes None Wood Door 12 Door Wood 18 0.387 0 0 0 90 No None Wood Door CASITA 3 Wall Wood 129 0.102 13 0 270 90 Yes IV.9 A3 WEST CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3 Project Title.......... P14510/OptB 2/Stdy/Casita Date..02/25/08 16:42:47 I MICROPAS7 v7.10 File-T_4510C2 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 5 Wall ----- Wood ---- 123 ----- 0.102 ----- 13 ----- 0 --- 0 ---- --- 90 Yes --------- IV.9 A3 -------------- NORTH 7 Wall Wood Ill 0.102 13 0 90 90 Yes IV.9 A3 EAST 10 RoofRad Wood 249 0.025 38 0 n/a 0 Yes IV.1 A18 Attic PERIMETER LOSSES Appendix Length F2 Insul Solar IV Location/ Surface ------------ (ft) ------ Factor R-val Gains Reference Comments HOUSE -------- ------- ----- --------- ---------------------- 13 S1abEdge 158 0.900 R-0 No None To Outside 14 S1abEdge 47 0.900 R-0 No None To Outside 15 S1abEdge 39 0.550 R-0 No None TO GARAGE FENESTRATION SURFACES Exterior Area U- Act Shade Orientation ------------------ (sf) ----- factor SHGC ----- ----- Azm --- Tilt ---- Type -------- Location/Comments HOUSE ------------------------ 1 Wind Back (S) 15.0 0.340 0.300 180 90 Standard SGLASSI/Vinyl/Operable W 2 Wind Back (S) 30.0 0.340 0.330 180 90 Standard SGLASS2/Vinyl/Fixed Wind 3 Wind Back (S) 15.0 0.340 0.300 180 90 Standard SGLASS3/Vinyl/Operable W 4 Door Back (S) 72.0 0.340 0.310 180 90 Standard SGLASS4/Vinyl/Sliding G1 5 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS5/French Door 6 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS6/Vinyl/Operable W 7 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS7/Vinyl/Operable W 8 Wind Right (W) 12.0 0.340 0.300 270 90 Standard WGLASSI/Vinyl/Operable W 9 Wind Right (W) 5.0 0.340 0.330 270 90 Standard WGLASS2/Vinyl/Fixed Wind 11 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS3/Vinyl/Operable W 12 Wind Front (N) 6.5 0.340 0.330 0 90 Standard NGLASS4/Vinyl/Fixed Wind 15 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W 16 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASS2/Vinyl/Operable W 17 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASS3/Vinyl/Operable W 18 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W 19 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASS5/Vinyl/Operable W 20 Door Left (E) 48.0 0.340 0.310 90 90 Standard EGLASS6/Vinyl/Sliding G1 CASITA 10 Wind Right (W) 6.0 0.340 0.300 270 90 Standard WGLASS3/Vinyl/Operable W 13 Wind Front (N) 15.0 0.340 0.300 0 90 Standard NGLASS5/Vinyl/Operable W 14 Wind Front (N) 15.0 0.340 0.300 0 90 Standard NGLASS6/Vinyl/Operable W 21 Door Left (E) 24.0 0.340 0.310 90 90 Standard EGLASS7/French Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4 Project Title.......... P14510/OptB 2/Stdy/Casita Date..02/25/08 16:42:47 I MICROPAS7 v7.10 File-T_4510C2 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface ----------- (sf) ----- Width ----- Height ------ Depth ----- Height Extension Extension HOUSE ------ --------- --------- 1 Window 15.0 2.50 6.00 8.00 0.50 n/a n/a 2 Window 30.0 5.00 6.00 8.00 0.50 n/a n/a 3 Window 15.0 2.50 6.00 8.00 0.50 n/a n/a 4 Door 72.0 9.00 8.00 8.00 0.50 n/a n/a 11 Window 18.0 3.00 6.00 6.00 0.50 n/a n/a 12 Window 6.5 6.50 0.83 6.00 0.50 n/a n/a 15 Window 18.0 3.00 6.00 2.00 0.50 n/a n/a 16 Window 18.0 3.00 6.00 2.00 0.50 n/a n/a 17 Window 18.0 3.00 6.00 2.00 0.50 n/a n/a 18 Window 18.0 3.00 6.00 2.00 0.50 n/a n/a 19 Window 18.0 3.00 6.00 6.00 0.50 n/a n/a 20 Door 48.0 6.00 8.00 6.00 1.00 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ HOUSE Standard Slab 1573 CASITA Standard Slab 249 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type Systems Efficiency EER or TXV Airflow Draw Capacity ------------ ------- ----------- ----- ------------- -------- -------- -------- HOUSE Furnace 0.8 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 0.8 14.00 SEER 11.5 Yes No No No CASITA HPSplit 0.2 7.70 HSPF n/a n/a n/a n/a n/a HPSplit 0.2 14.00 SEER 11.5 Yes No No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... P14510/OptB 2/Stdy/Casita Date..02/25/08 16:42:47 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T_4510C2 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- HVAC SIZING Total Sensible Heating Cooling System Load Load Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- - HOUSE Furnace 34634 n/a ACSplit n/a 24989 CASITA Verified Design Maximum Cooling Cooling Capacity Capacity (Btu/hr) --------- (Btu/hr) ---------- n/a n/a 31011 n/a HPSplit 4514 n/a n/a n/a HPSplit ------------- n/a ---------- 6795 ---------- 8433 n/a Total 39147 31784 -------------------- 39444 n/a Orientation of Maximum..... Front Facing 270 deg (W) Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range.... ......... 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location ----------- R-value Leakage Area Ducts HOUSE ------- --------------- --------- Furnace Attic R-6 Yes No No ACSplit Attic R-6 Yes No No CASITA HPSplit Attic R-6 Yes No No HPSplit Attic R-6 Yes No No WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 6 Project Title.......... P14510/OptB 2/Stdy/Casita Date..02/25/08 16:42:47 I MICROPAS7 v7.10 File-T_4510C2 Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a'HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 7 Project Title.......... P14510/OptB 2/Stdy/Casita Date..02/25/08 16:42:47 MICROPAS7 v7.10 File-T_4510C2 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and.,performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... Kyle Tibbitts Name.... Chinh Nguyen Company. Shea Homes/Trilogy Company. Westpac Air Conditioning, Inc. Address. 60946 Desert Rose Address. 1610 N. Maple St. La Quinta, CA 92253 Corona, CA 92880 Phone... (760) 777-6026 Phone... (951) 739-9501 License.( ZZg�j Signed.. Signed.. JV (date) (dat�YZ�/ ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 1 Project Title.......... P14510/OptB 2/Stdy/Casita Date..02/25/08 16:42:47 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I 1610 N. Maple St. I Plan Check / Date Corona, CA 92880 I I (951) 739-9501 1 Field Check/ Date 1 Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. I MICROPAS7 v7.10 File-T_4510C2 Wth-CTZ15S05 Program -FORM MF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling v 150(b): Loose fill insulation manufacturer's labeled R-Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire i opening of the firebox b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed —� 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF-6R form 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls .1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 2 Project Title.......... P14510/OptB 2/Stdy/Casita Date..02/25/08 16:42:47 I MICROPAS7 v7.10 File-T_4510C2 Wth-CTZ15S05 Program -FORM MF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En- sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space 7. Solar water -heating systems/collectors are certified by the; Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, __z MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 3 Project Title.......... P14510/OptB 2/Stdy/Casita Date..02/25/08 16:42:47 I MICROPAS7 v7.10 File-T_4510C2 Wth-CTZ15S05 Program -FORM MF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch 115: Gas -fired central furnaces, pool heaters, spa heaters or�� household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) / 118(i): Cool Roof material meets specified criteria —� RESIDENTIAL LIGHTING MEASURES n/a 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic De- En- sign- force er ment MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 4 Project Title.......... P14510/OptB 2/Stdy/Casita Date..02/25/08 16:42:47 I MICROPAS7 v7.10 File-T_4510C2 Wth-CTZ15S05 Program -FORM MF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La ------------------------------------------------------------------------------- Quinta P-1 and have an output frequency no less than 20 kHz / 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 1.50(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires.(not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) SHEA HOMES PRODUCT-1 TRILOGY AT LA QUINTA PLAN -4520 Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 1 Project Title.......... Plan 4520 Standard Date..02/25/08 16:43:46 Project Address........ ******* --------------------- La Quinta, CA *v7.10* ► I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. 1 1 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 I 1 (951) 739-9501 1 Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. I MICROPAS7 v7.10 File-TRI 4520 Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac ------------------------------------------------------------------------------- Air Conditioning, Run -Trilogy at La Quinta P-1 I ---------------------------- ---------------------------- MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) ---------------------------------- Design ---------- Design ----------- Margin = Space Heating.......... 1.72 1.19 0.53 = - Space Cooling.......... 74.14 55.08 19.06 = - Water Heating 12.82 11.70 1.12 = = North Total 88.68 67.97 20.71 = = Space Heating.......... 1.72 1.48 0.24 = - Space Cooling.......... 74.14 57.04 17.10 = - Water Heating 12.82 11.70 1.12 = = East Total 88.68 70.22 18.46 = = Space Heating.......... 1.72 1.65 0.07 = = Space Cooling.......... 74.14 54.36 19.78 = - Water Heating 12.82 11.70 1.12 = = South Total 88.68 67.71 20.97 = = Space Heating.......... 1.72 1.29 0.43 = = Space Cooling.......... 74.14 55.92 18.22 = - Water Heating.......... 12.82 11.70 1.12 = = West Total 88.68 68.91 19.77 = _ *** Building complies with Computer Performance _ *** HERS Verification Required for Compliance *** _ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 Project Title.......... Plan 4520 Standard Date..02/25/08 16:43:46 I MICROPAS7 v7.10 File-TRI_4520 Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 1662 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 14958 cf 1662 sf 20.5 % of floor area 0.34 Btu/hr-sf-F 0.3 9 ft BUILDING ZONE INFORMATION Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ----- ------------- ----- ------- ---------- Residence 1662 14958 1.00 4.0 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface ------------ Type ----- (sf) ---- or R-val R-val Azm Tilt Reference Comments 1 Wall Wood 213 ----- 0.102 ----- 13 ----- 0 --- 180 ---- 90 --- Yes --------- IV.9 A3 -------------- SOUTH 2 Wall Wood 313 0.102 13 0 270 90 Yes IV.9 A3 WEST 3 Wall Wood 134 0.102 13 0 0 90 Yes IV.9 A3 NORTH 4 Wall Wood 312 0.102 13 0 90 90 Yes IV.9 A3 EAST 5 Wall Wood 180 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 6 RoofRad Wood 1662 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 7 Door Wood 20 0.387 0 0 0 90 Yes None Wood Door 8 Door Wood 18 0.387 0 0 0 90 No None Wood Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3 Project Title.......... Plan 4520 Standard Date..02/25/08 16:43:46 ---------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_4520 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- PERIMETER LOSSES ---------------- Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ 9 S1abEdge ------ 148 -------- 0.900 ------- R-0 ----- No --------- None ---------------------- To Outside 10 S1abEdge 22 0.550 R-0 No None TO GARAGE FENESTRATION SURFACES Exterior Area U- Act Shade Orientation ------------------ (sf) ----- factor ----- SHGC ----- Azm --- Tilt ---- Type -------- Location/Comments ------------------------ 1 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASSI/Vinyl/Sliding Gl 2 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS2/Vinyl/Operable W 3 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS3/Vinyl/Operable W 4 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS4/Vinyl/Operable W 5 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS5/Vinyl/Sliding G1 6 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS6/Vinyl/Operable W 7 Wind Right (W) 12.0 0.340 0.300 270 90 Standard WGLASSI/Vinyl/Operable W 8 Wind Right (W) 6.0 0.340 0.300 270 90 Standard WGLASS2/Vinyl/Operable W 9 Wind Right (W) 4.0 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind 10 Wind Right (W) 25.0 0.340 0.300 270 90 Standard WGLASS4/Vinyl/Operable W 11 Wind Front (N) 6.0 0.340 0.330 0 90 Standard NGLASSI/Vinyl/Fixed Wind 12 Wind Front (N) 5.5 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind 13 Wind Front (N) 6.0 0.340 0.330 0 90 Standard NGLASS3/Vinyl/Fixed Wind 14 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W 15 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS5/Vinyl/Operable W 16 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W 17 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS2/Vinyl/Operable W 18 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS3/Vinyl/Operable W 19 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface ----------- (sf) ----- Width Height Depth Height Extension Extension 1 Door 48.0 ----- 6.00 ------ 8.00 ----- 6.00 ------ 0.50 --------- n/a --------- n/a 2 Window 36.0 6.00 6.00 7.00 0.50 n/a n/a 3 Window 36.0 6.00 6.00 7.00 0.50 n/a n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4 Project Title.......... Plan 4520 Standard Date..02/25/08 16:43:46 I MICROPAS7 v7.10 File-TRI_4520 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ Standard Slab 1662 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum .System of Minimum Refrig Charge Adequate Fan Watt Cooling Type ------------ Systems Efficiency EER or TXV Airflow Draw Capacity Furnace ------- 1 ----------- ----- ------------- 0.800 AFUE n/a n/a -------- n/a -------- n/a -------- n/a ACSplit 1 14.00 SEER 11.5 Yes No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) Furnace 30301 n/a n/a ---------- n/a ACSplit n/a 24991 31014 n/a Orientation of Maximum..... Front Facing 270 deg (W) Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location ----------- R-value Leakage ------- Area Ducts Furnace Attic ------- R-6 Yes -------- No --------- No ACSplit Attic R-6 Yes No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4520 Standard Date..02/25/08 16:43:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_4520 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- WATER HEATING SYSTEMS --------------------- Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of .a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test. or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 6 Project Title.......... Plan 4520 Standard Date..02/25/08 16:43:4"6 I MICROPAS7 v7.10 File-TRI_4520 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION -------------------------- redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations,.and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER Name.... Kyle Tibbitts Company. Shea Homes/Trilogy Address. 60946 Desert Rose La Quinta, CA 92253 Phone... (760) 777-6026 License. Z Signed.. _ (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Chinh Nguyen Company. Westpac Air Conditioning, Inc. Address. 1610 N. Maple St. Corona, CA 92880 Phone... (951) 739-9501 Signed.. �j f (dat ) MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 1 Project Title.......... Plan 4520 Standard Date..02/25/08 16:43:46 Project Address........ La Quinta, CA Documentation Author... Chinh Nguyen Westpac Air Conditioning, 1610 N. Maple St. Corona, CA 92880 (951) 739-9501 ******* --------------------- *v7.10* I I ******* I Building Permit # I Inc. I Plan Check / Date I I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------=------------------------------------=----- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_4520 Wth-CTZ15S05 Program -FORM MF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or p equivalent U-factor in metal frame ceiling 150(b): Loose fill insulation manufacturer's labeled R-Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls) LA *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire / opening of the firebox b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only y� 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.30, water vapor permeance rate no greater than 2.0 perm/inch —z 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF-6R form 116-17: Fenestration Products, Exterior Doors and Infiltration Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 2 Project Title.......... Plan 4520 Standard Date..02/25/08 16:43:46 I MICROPAS7 v7.10 File-TRI_4520 Wth-CTZ15S05 Program -FORM MF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En- sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance / with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or / cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A 5. Insulation must be protected from damage, including that Wu to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space 7. Solar water -heating systems/collectors are certified by the, Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4520 Standard Date..02/25/08 16:43:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_4520 Wth-CTZ15S05 Program -FORM MF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts / 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with / mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating / b. Cover for outdoor pools or outdoor spas. J 3. Pool system has directional inlets and a circulation pump time switch 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances ,! with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 4 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4520 Standard Date..02/25/08 16:43:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_4520 Wth-CTZ15S05 Program -FORM MF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- and have an output frequency no less than 20 kHz 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option j 150(k)4: Permanently installed luminaires located other than T in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall ` have lighting that complies with Sec. 130, 131, and 146 V 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) SHEA HOMES PRODUCT-1 TRILOGY AT LA QUINTA PLAN -4520/OPT. BAY 2 Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER ------------------------------------------------------------------------------- METHOD CF-1R Page 1 ------------------------------------------------------------------------------- Project Title.......... Plan 4520/Option Bay 2 Date..02/25/08 16:44:32 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # Westpac Air Conditioning, Inc. I I 1610 N. Maple St. I Plan Check / Date Corona, CA 92880 I I (951) 739-9501 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... ------------------------------------------------------------------------------- MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4520OB2 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac ------------------------------------------------------------------------------- Air Conditioning, Run -Trilogy at La Quinta P-1 I ---------------------------- ---------------------------- MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) _----------------------- ---------- Design Design -------------------- Margin = - - Space Heating.......... 1.64 1.08 0.56 = = Space Cooling.......... 72.20 53.93 18.27 = = Water Heating.......... 12.70 11.60 1.10 = = North Total 86.54 66.61 19.93 = = Space Heating.......... 1.64 1.45 0.19 = = Space Cooling.......... 72.20 55.56 16.64 = = Water Heating.......... 12.70 11.60 1.10 = = East Total 86.54 68.61 17.93 = = Space Heating.......... 1.64 1.69 -0.05 = - Space Cooling.......... 72.20 52.81 19.39 = = Water Heating.......... 12.70 11.60 1.10 = = South Total 86.54 66.10 20.44 = - Space Heating.......... 1.64 1.25 0.39 = = Space Cooling.......... 72.20 54.09 18.11 = = Water Heating.......... 12.70 11.60 1.10 = = West Total 86.54 66.94 19.60 = _ *** Building complies with Computer Performance _ *** ----------------------------------------------------------------- ----------------------------------------------------------------- HERS Verification Required for Compliance CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 --=---------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4520/Option Bay 2 Date..02/25/08 16:44:32 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T4520OB2 Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 1688 sf Building Type.............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 15218 cf 1688 sf 19 % of floor area 0.34 Btu/hr-sf-F 0.31 9 ft BUILDING ZONE INFORMATION ------------------------- Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ----- ------------- ----- ------- ---------- Residence 1688 15218 1.00 4.0 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 1 Wall ----- Wood ---- 213 ----- 0.102 ----- 13 ----- 0 --- 180 ---- 90 --- Yes --------- IV.9 A3 -------------- SOUTH 2 Wall Wood 313 0.102 13 0 270 90 Yes IV.9 A3 WEST 3 Wall Wood 153 0.102 13 0 0 90 Yes IV.9 A3 NORTH 4 Wall Wood 312 0.102 13 0 90 90 Yes IV.9 A3 EAST 5 Wall Wood 180 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 6 RoofRad Wood 1662 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 7 Door Wood 20 0.387 0 0 0 90 Yes None Wood Door 8 Door Wood 18 0.387 0 0 0 90 No None Wood Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4520/Option Bay 2 Date..02/25/08 16:44:32 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4520OB2 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- PERIMETER LOSSES Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ 9 SlabEdge ------ 148 -------- 0.900 ------- R-0 ----- No --------- None ---------------------- To Outside 10 SlabEdge 22 0.550 R-0 No None TO GARAGE FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ 1 Door Back (S) ----- 48.0 ----- 0.340 ----- 0.310 --- 180 ---- 90 -------- Standard ------------------------ SGLASSI/Vinyl/Sliding G1 2 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS2/Vinyl/Operable W 3 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS3/Vinyl/Operable W 4 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS4/Vinyl/Operable W 5 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASSS/French Door 6 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS6/Vinyl/Operable W 7 Wind Right (W) 12.0 0.340 0.300 270 90 Standard WGLASSI/Vinyl/Operable W 8 Wind Right (W) 6.0 0.340 0.300 270 90 Standard WGLASS2/Vinyl/Operable W 9 Wind Right (W) 4.0 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind 10 Wind Right (W) 25.0 0.340 0.300 270 90 Standard WGLASS4/Vinyl/Operable W 11 Wind Front (N) 5.0 0.340 0.330 0 90 Standard NGLASSI/Vinyl/Fixed Wind 12 Wind Front (N) 5.5 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind 13 Wind Front (N) 5.0 0.340 0.330 0 90 Standard NGLASS3/Vinyl/Fixed Wind 14 Wind Front (N) 4.0 0.340 0.330 0 90 Standard NGLASS4/Vinyl/Fixed Wind 15 Wind Front (N) 15.0 0.340 0.300 0 90 Standard NGLASSS/Vinyl/Operable.W 16 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W 17 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS2/Vinyl/Operable W 18 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS3/Vinyl/Operable W 19 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W OVERHANGS Window--- ------------ Overhang ------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- 1 Door ----- 48.0 ----- 6.00 ------ 8.00 ----- 6.00 ------ 0.50 --------- n/a --------- n/a 2 Window 36.0 6.00 6.00 6.00 0.50 n/a n/a 3 Window 36.0 6.00 6.00 6.00 0.50 n/a n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 Project Title.......... Plan 4520/Option Bay 2 Date..02/25/08 16:44:32 -------=----------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T4520OB2 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ Standard Slab 1688 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type ------------ Systems Efficiency EER or TXV Airflow Draw Capacity Furnace ------- 1 ----------- ----- ------------- 0.800 AFUE n/a n/a -------- n/a -------- n/a -------- n/a ACSplit 1 14.00 SEER 11.5 Yes No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) Furnace 30190 n/a n/a ---------- n/a ACSplit n/a 24569 30490 n/a Orientation of Maximum..... Sizing Location............ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range ............... Front Facing 270 deg (W) LA QUINTA 26 F 70 F 111 F 75 F 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location ----------- R-value Leakage Area Ducts Furnace Attic -------------- R-6 Yes -------- No --------- No ACSplit Attic R-6 Yes No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4520/Option Bay 2 Date..02/25/08 16:44:32 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4520OB2 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ----------------------------------------------------------------------- ------ WATER HEATING SYSTEMS --------------------- Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6 Project Title.......... Plan 4520/Option Bay 2 Date..02/25/08 16:44:32 MICROPAS7 v7.10 File-T4520OB2 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION -------------------------- redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... Kyle Tibbitts Name.... Chinh Nguyen Company. Shea Homes/Trilogy Company. Westpac Air Conditioning, Inc. Address. 60946 Desert Rose Address. 1610 N. Maple St. La Quinta, CA 92253 Corona, CA 92880 Phone... (760) 777- 26 Phone... (951) 739-9501 License. q( 7-z15 Signed.. �� QU Signed.. 2i Z•b (date) (da e) / .l' ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 1 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4520/Option Bay 2 Date..02/25/08 16:44:32 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I I 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 I I (951) 739-9501 Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4520OB2 Wth-CTZ15S05 Program -FORM MF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling-5 150(b): Loose fill insulation manufacturer's labeled R-Value / *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls) ,13 *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox ✓ b. Outside air intake with damper.and control, flue damper and control 2. No continuous burning gas pilot lights allowed 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual / 150(g): Vapor barriers mandatory in Climate Zones 14,16 only / 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF-6R form 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 2 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4520/Option Bay 2 Date..02/25/08 16:44:32 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T4520OB2 Wth-CTZ15S05 Program -FORM MF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ---------------------------------------------------- -------------------------- label.with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints ` and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En- sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor, less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-`/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to .Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A 5. Insulation must be protected from damage, including that Cie to sunlight, moisture, equipment maintenance and wind / 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space ` 7. Solar water -heating systems/collectors are certified by the , Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4520/Option Bay 2 Date..02/25/08 16:44:32 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T4520OB2 Wth-CTZ15S05 Program -FORM MF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating b. Cover for outdoor pools or outdoor spas. !/ 3. Pool system has directional inlets and a circulation pump time switch 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) l 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R ------------------------------------------------------------------------------- Page 4 ------------------------------------------------------------------------------- Project Title.......... Plan 4520/Option Bay 2 Date..02/25/08 16:44:32 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4520OB2 Wth-CTZ15S05 Program -FORM MF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- and have an output frequency no less than 20 kHz / 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall ��- be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn.on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air / tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply / / with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to ` comply with Section 119(d) / SHEA HOMES PRODUCT-1 TRILOGY AT LA QUINTA PLAN -4520/OPT. BAY 21CASITA Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF ------------------------------------------------------------------------------- COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 1 ------------------------------------------------------------------------------- Project Title.......... P1.4520/Opt.Bay2/Casita Date..02/25/08 16:45:10 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I 1610 N. Maple St. I Plan Check / Date I Corona, 'CA 92880 I I (951) 739-9501 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... ------------------------------------------------------------------------------- MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4520CST Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 ------------------------------------ User-Westpac Air Conditioning, 7------------------------------------------ Run -Trilogy at La Quinta P-1 I ----------------------------------------------------------------- ----------------------------------------------------------------- = - MICROPAS7 ENERGY USE SUMMARY = - = Energy Use ----------- ----------------- Standard Proposed Compliance = _ (kTDV/sf-yr) _----------------------- Design ---------- Design ---------- Margin = ---------- - = Space Heating.......... 2.09 1.77 0.32 = = Space Cooling.......... 75.97 58.36 17.61 = = Water Heating.......... 11.71 10.74 0.97 = = North Total 89.77 70.87 18.90 = = Space Heating.......... 2.09 2.15 -0.06 = - Space Cooling.......... 75.97 60.53 15.44 = = Water Heating.......... 11.71 10.74 0.97 = = East Total 89.77 73.42 16.35 = = Space Heating...... .. 2.09 2.39 --0.30 = = Space Cooling.......... 75.97 56.60 19.37 = = Water Heating.......... 11.71 10.74 0.97 = = South Total 89.77 69.73 20.04 = = Space Heating.......... 2.09 1.91 0.18 = = Space Cooling.......... 75.97 58.91 17.06 = = Water Heating.......... 11.71 10.74 0.97 = = West Total 89.77 71.56 18.21 = _ *** Building complies with Computer Performance _ ----------------------------------------------------------------- ----------------------------------------------------------------- *** HERS Verification Required for Compliance CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2 Project Title.......... P1.4520/Opt.Bay2/Casita Date..02/25/08 16:45:10 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4520CST Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 1943 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 2 17513 cf 1943 sf 20.3 % of floor area 0.34 Btu/hr-sf-F 0.31 9 ft BUILDING ZONE INFORMATION Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type -------------- (sf) ----- (cf) ------ Units ----- le ----- ioned ----- Type -------- (ft) ----- (sf) Housewrap ------- ---------- HOUSE Residence 1688 15218 0.80 3.2 Yes Setback 2.0 Standard No CASITA Residence 255 2295 0.20 0.8 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface ------------ Type (sf) or R-val R-val Azm Tilt Reference Comments HOUSE ----- ---- ----- ----- ----- --- ---- --- --------- -------------- 1 Wall a Wood 213 0.102 13 0 180 90 Yes IV.9 A3 SOUTH 3 Wall Wood 313 0.102 13 0 270 90 Yes IV.9 A3 WEST 5 Wall Wood 153 0.102 13 0 0 90 Yes IV.9 A3 NORTH 7 Wall Wood 312 0.102 13 0 90 90 Yes IV.9 A3 EAST 9 Wall Wood 180 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 10 RoofRad Wood 1662 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 12 Door Wood 20 0.387 0 0 0 90 Yes None Wood Door 13 Door Wood 18 0.387 0 0 0 90 No None Wood Door CASITA 2 Wall Wood 105 0.102 13 0 180 90 Yes IV.9 A3 SOUTH CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3 Project Title.......... P1.4520/Opt.Bay2/Casita Date..02/25/08 16:45:10 MICROPAS7 v7.10 File-T4520CST Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 4 Wall ----- Wood ---- 129 ----- 0.102 ----- 13 ----- --- ---- --- 0 270 90 Yes --------- IV.9 A3 -------------- WEST 6 Wall Wood 134 0.102 13 0 0 90 Yes IV.9 A3 NORTH 8 Wall Wood 135 0.102 13 0 90 90 Yes IV.9 A3 EAST 11 RoofRad Wood 255 0.025 38 0 n/a 0 Yes IV.1 A18 Attic PERIMETER LOSSES ---------------- Appendix Length F2 Insul Solar IV Location/ Surface ------------ (ft) ------ Factor -------- R-val ------- Gains Reference ----- --------- Comments --------------=------- HOUSE 14 S1abEdge 148 0.900 R-0 No None To Outside 16 S1abEdge 22 0.550 R-0 No None TO GARAGE CASITA 15 S1abEdge 64 0.900 R-0 No None To Outside FENESTRATION SURFACES Exterior Area U- Act Shade Orientation ------------------ (sf) ----- factor SHGC ----- ----- Azm --- Tilt ---- Type -------- Location/Comments ------------------------ HOUSE 1 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASSI/Vinyl/Sliding G1 2 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS2/Vinyl/Operable W 3 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS3/Vinyl/Operable W 4 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS4/Vinyl/Operable W 5 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS5/Vinyl/Sliding G1 6 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS6/Vinyl/Operable W 8 Wind Right (W) 12.0 0.340 0.300 270 90 Standard WGLASSI/Vinyl/Operable W 9 Wind Right (W) 6.0 0.340 0.300 270 90 Standard WGLASS2/Vinyl/Operable W 10 Wind Right (W) 4.0 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind 11 Wind Right (W) 25.0 0.340 0.300 270 90 Standard WGLASS4/Vinyl/Operable W 13 Wind Front (N) 5.0 0.340 0.330 0 90 Standard NGLASSI/Vinyl/Fixed Wind 14 Wind Front (N) 5.5 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind 15 Wind Front (N) 5.0 0.340 0.330 0 90 Standard NGLASS3/Vinyl/Fixed Wind 16 Wind Front (N) 4.0 0.340 0.330 0 90 Standard NGLASS4/Vinyl/Fixed Wind 17 Wind Front (N) 15.0 0.340 0.300 0 90 Standard NGLASS5/Vinyl/Operable W 20 Wind Left (E) 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W 21 Wind Left (E) _12.0 12.0 0.340 0.300 90 90 Standard EGLASS2/Vinyl/Operable W 22 Wind Left (E) 12.0 0.340 0.300 90 90 Standard SGLASS3/Vinyl/Operable W 23 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W CASITA CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4 Project Title.......... P1.4520/Opt.Bay2/Casita Date..02/25/08 16:45:10 I MICROPAS7 v7.10 File-T4520CST Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac-Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ 7 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS7/Vinyl/Sliding G1 12 Wind Right (W) 6.0 0.340 0.300 270 90 Standard WGLASSS/Vinyl/Operable W 18 Wind Front (N) 15.0 0.340 0.300 0 90 Standard NGLASS6/Vinyl/Operable W 19 Wind Front (N) 4.0 0.340 0.330 0 90 Standard NGLASS7/Vinyl/Fixed Wind OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- ----- ----- ------ ----- ------ --------- --------- HOUSE 1 Door 48.0 6.00 8.00 6.00 0.50 n/a n/a 2 Window 36.0 6.00 6.00 7.00 0.50 n/a n/a 3 Window 36.0 6.00 6.00 7.00 0.50 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ HOUSE Standard Slab 1688 CASITA Standard Slab 255 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling .Type ------------ Systems ------- Efficiency EER or TXV Airflow Draw Capacity HOUSE ----------- ----- ------------- -------- -------- -------- Furnace 1 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 1 14.00 SEER 11.5 Yes No No No CASITA HPSplit 1 7.70 HSPF n/a n/a n/a n/a n/a HPSplit 1 14.00 SEER 11.5 Yes No No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... P1.4520/Opt.Bay2/Casita Date..02/25/08 16:45:10 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T4520CST Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I --------------------------------------------------------- --------------------- HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- HOUSE Furnace 3,0190 n/a n/a n/a ACSplit n/a 23785 29517 n/a CASITA HPSplit 8463 n/a n/a n/a HPSplit n/a 6257 7765 n/a ------------- Total ---------- 38652 ---------- 30042 ---------- 37282 ---------- n/a Orientation of Maximum..... Sizing Location............ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range ............... Front Facing 90 deg (E) LA QUINTA 26 F 70 F 111 F 75 F 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location ----------- R-value Leakage Area Ducts HOUSE ------- ------- -------- --------- Furnace Attic R-6 Yes No No ACSplit Attic R-6 Yes No No CASITA HPSplit Attic R-6 Yes No No HPSplit Attic R-6 Yes No No WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 6 Project Title.......... P1.4520/Opt.Bay2/Casita Date..02/25/08 16:45:10 I MICROPAS7 v7.10 File-T4520CST Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 7 Project Title.......... P1.4520/Opt.Bay2/Casita Date..02/25/08 16:45:10 ----------- I MICROPAS7 v7.10 File-T4520CST Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- REMARKS COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... Kyle Tibbitts Company. Shea Homes/Trilogy Address. 60946 Desert Rose La Quinta, CA 92253 Phone... (760 777-6026 License. ZzQf Signed.. —�—y , (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) Name.... Chinh Nguyen Company. Westpac Air Conditioning, Inc. Address. 1610 N. Maple St. Corona, CA 92880 Phone... (951) 739-9501 Signed.. 7.,6 (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 1 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... P1.4520/Opt.Bay2/Casita Date..02/25/08 16:45:10 Project Address........ ******* --------------------- Documentation Author... Climate Zone........... La Quinta, CA Chinh Nguyen Westpac Air Conditioning, 1610 N. Maple St. Corona, CA 92880 (951) 739-9501 15 *v7.10* 1 I ******* I Building Permit # I Inc. I I I Plan Check / Date I I I Field Check/ Date I --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T4520CST Wth-CTZ15S05 Program -FORM MF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling 150(b): Loose fill insulation manufacturer's labeled R-Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF-6R form 116-17: Fenestration Products, Exterior Doors and Infiltration Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 2 Project Title.......... P1.4520/Opt.Bay2/Casita Date..02/25/08 16:45:10 MICROPAS7 v7.10 File-T4520CST Wth-CTZ15S05 Program -FORM MF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En- sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-P,/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A 5. Insulation must be protected from damage, including that d to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space 7. Solar water -heating systems/collectors are certified by t Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated'to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, �L MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 3 Project Title.......... P1.4520/Opt.Bay2/Casita Date..02/25/08 16:45:10 I MICROPAS7 v7.10 File-T4520CST Wth-CTZ15S05 Program -FORM MF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause / reductions in the cross -sectional area of the ducts 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 4 Project Title.......... P1.4520/Opt.Bay2/Casita Date..02/25/08 16:45:10 MICROPAS7 v7.10 File-T4520CST Wth-CTZ15S05 Program -FORM MF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- and have an output frequency no less than 20 kHz y� 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, -� garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option / 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) .that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air / tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) SHEA HOMES PRODUCT-1 TRILOGY AT LA QUINTA PLAN -4515 Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1 Project Title.......... Plan 4515 Standard Date..02/25/08 16:45:46 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. 1 1 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 1 1 (951) 739-9501 1 Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. I MICROPAS7 v7.10 File-TRI_4515 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 1 ------------------------------------------------------------------------------- ---------------------------- ---------------------------- MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) _----------------------- ---------- Design ---------- Design ---------- Margin = = Space Heating.......... 2.28 2.03 - 0.25 = = Space Cooling.......... 78.95 60.51 18.44 = - Water _ Heating.......... 12.43. 11.37 1.06 = = North Total ---------------- 93.66 -------- 73.91 - 19.75 = = Space Heating.......... 2.28 2.23 0.05 = - Space Cooling.......... 78.95 61.06 17.89 = - Water _ Heating 12.43 -------- 11.37 1.06 = = East Total -------- 93.66 -------- 74.66 - 19.00 = = Space Heating.......... 2.28 2.42 -0.14 = - Space Cooling.......... 78.95 60.42 18.53 = = Water _ Heating.......... 12.43 11.37 1.06 = = South Total ---------------- 93.66 -------- 74.21 - 19.45 = = Space Heating.......... 2.28 2.14 0.14 = - Space Cooling.......... 78.95 59.46 19.49 = - Water _ Heating.......... 12.43 -------- 11.37 1.06 = = West Total -------- 93.66 -------- 72.97 - 20.69 = _ *** Building complies with Computer Performance _ *** HERS Verification Required for Compliance *** _ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2 Project Title.......... Plan 4515 Standard Date..02/25/08 16:45:46 I MICROPAS7 v7.10 File-TRI_4515 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 1749 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 17636 cf 1749 sf 21.1 % of floor area 0.34 Btu/hr-sf-F 0.31 10.1 ft BUILDING ZONE INFORMATION Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ------ ------------- ----- ------- ---------- Residence 1749 17636 1.00 4.0 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface ------------ Type ----- (sf) ---- or ----- R-val R-val Azm Tilt Reference Comments 1 Wall Wood 291 0.102 ----- 13 ----- 0 --- 180 ---- 90 --- Yes --------- IV.9 A3 -------------- SOUTH 2 Wall Wood 498 0.102 13 0 270 90 Yes IV.9 A3 WEST 3 Wall Wood 158 0.102 13 0 0 90 Yes IV.9 A3 NORTH 4 Wall Wood 545 0.102 13 0 90 90 Yes IV.9 A3 EAST 5 Wall Wood 214 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 6 RoofRad Wood 1749 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 7 Door Wood 24 0.387 0 0 0 90 Yes None Wood Door 8 Door Wood 18 0.387 0 0 0 90 No None Wood Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4515 Standard Date..02/25/08 16:45:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_4515 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- PERIMETER LOSSES ---------------- Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ 9 SlabEdge ------ 187 -------- 0.900 ------- R-0 ----- No --------- None ---------------------- To Outside 10 SlabEdge 23 0.550 R-0 No None TO GARAGE FENESTRATION SURFACES Exterior Area U- Act Shade Orientation ------------------ (sf) ----- factor ----- SHGC ----- Azm --- Tilt ---- Type -------- Location/Comments ------------------------ 1 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASSI/Vinyl/Operable W 2 Wind Back (S) 24.0 0.340 0.330 180 90 Standard SGLASS2/Vinyl/Fixed Wind 3 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS3/Vinyl/Operable W 4 Wind Back (S) 18.0 0.340 0.300 180 90 Standard SGLASS4/Vinyl/Operable W 5 Wind Back (S) 36.0 0.340 0.330 180 90 Standard SGLASSS/Vinyl/Fixed Wind 6 Wind Back (S) 18.0 0.340 0.300 180 90 Standard SGLASS6/Vinyl/Operable W 7 Door Back (S) 42.7 0.340 0.310 180 90 Standard SGLASS7/French Door 8 Door Right (W) 48.0 0.340 0.310 270 90 Standard WGLASSI/Vinyl/Sliding G1 9 Wind Right (W) 4.0 0.340 0.330 270 90 Standard WGLASS2/Vinyl/Fixed Wind 10 Wind Right (W) 4.0 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind 11 Wind Right (W) 6.0 0.340 0.300 270 90 Standard WGLASS4/Vinyl/Operable W 12 Wind Right (W) 6.0 0.340 0.330 270 90 Standard WGLASSS/Vinyl/Fixed Wind 13 Wind Right (W) 18.0 0.340 0.300 270 90 Standard WGLASS6/Vinyl/Operable W 14 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASSI/Vinyl/Operable W 15 Wind Front (N) 6.0 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind 16 Wind Front (N) 26.0 0.340 0.300 0 90 Standard NGLASS3/Vinyl/Operable W 17 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W 18 Wind Left (E) 6.0 0.340 0.300 90 90 Standard SGLASS2/Vinyl/Operable W 19 Wind Left (E) 10.0 0.340 0.300 90 90 Standard EGLASS3/Vinyl/Operable W 20 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W 21 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASSS/Vinyl/Operable W OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface ----------- (sf) Width Height Depth Height Extension Extension 4 Window ----- 18.0 ----- 3.00 ------ 6.00 ----- 7.00 ------ 0.50 --------- n/a --------- n/a 5 Window 36.0 6.00 6.00 7.00 0.50 n/a n/a 6 Window 18.0 3.00 6.00 7.00 0.50 n/a n/a 7 Door 42.7 5.33 8.00 7.00 0.50 n/a n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4515 Standard Date..02/25/08 16:45:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_4515 Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface ----------- (sf) ----- Width ----- Height ------ Depth ----- Height ------ Extension --------- Extension --------- 8 Door 48.0 6.00 8.00 7.00 0.50 n/a n/a 13 Window 18.0 3.00 6.00 7.00 0.50 n/a n/a 15 Window 6.0 1.00 6.00 7.00 0.50 n/a n/a 17 Window 18.0 3.00 6.00 7.00 0.50 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ Standard Slab 1749 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type Systems Efficiency EER or TXV Airflow Draw Capacity ------------ Furnace ------- 1 ----------- ----- ------------- 0.800 AFUE n/a n/a -------- n/a -------- n/a -------- n/a. ACSplit 1 14.00 SEER 11.5 Yes No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- Furnace 36222 n/a n/a n/a ACSplit n/a 27246 33812 n/a Orientation of Maximum..... Sizing Location............ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range ............... Front Facing 0 deg (N) LA QUINTA 26 F 70 F 111 F 75 F 34 F CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4515 Standard Date..02/25/08 16:45:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_4515 Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location R-value Leakage Area Ducts Furnace ----------- Attic -------------- R-6 Yes -------- No -------- No ACSplit Attic R-6 Yes No No WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 6 -------------=----------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4515 Standard Date..02/25/08 16:45:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_4515 Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION -----------------_--------- This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 7 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4515 Standard Date..02/25/08 16:45:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_4515 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER Name.... Kyle Tibbitts Company. Shea Homes/Trilogy Address. 60946 Desert Rose La Quinta, CA 92253 Phone... (760) 777-6026 License. �p yz95 Signed.. Arf (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Chinh Nguyen Company. Westpac Air Conditioning, Inc. Address. 1610 N. Maple St. Corona, CA 92880 Phone... (951) 739-9501 Signed..��� (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 1 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4515 Standard Date..02/25/08 16:45:46 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I 1 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 I 1 (951) 739-9501 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_4515 Wth-CTZ15S05 Program -FORM MF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling 150(b): Loose fill insulation manufacturer's labeled R-Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls)i� *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.30, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF-6R form 116-17: Fenestration Products, Exterior Doors and Infiltration Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 2 Project Title.......... Plan 4515 Standard Date..02/25/08 16:45:46 I MICROPAS7 v7.10 File-TRI_4515 Wth-CTZ15S05 Program -FORM MF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain / Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES n/a 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A 5. Insulation must be protected from damage, including that d to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, De- En- sign- force er ment MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 3 ----------------------------------------------------------------------- --------- ------------------------------------------------------------------------------- Project Title.......... Plan 4515 Standard Date..02/25/08 16:45:46 MICROPAS7 v7.10 File-TRI_4515 Wth-CTZ15S05 Program -FORM MF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 1 ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used / 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts 3. Joints and seams of duct systems and their components _ shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers / 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually / operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light r� 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating b. Cover for outdoor pools or outdoor spas. / 3. Pool system has directional inlets and a circulation pump time switch 115: Gas -fired central furnaces, pool heaters, spa heaters or� household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R ------------------------------------------------------------------------------- Page 4 ------------------------------------------------------------------------------- Project Title.......... Plan 4515 Standard Date..02/25/08 16:45:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_4515 Wth-CTZ15S05 Program -FORM MF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- and have an output frequency no less than 20 kHz 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Seca 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings _ are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air j tight (AT) to less than 2.0 CFM at 75 Pascals / 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply / with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) SHEA HOMES PRODUCT-1 TRILOGY AT LA QUINTA PLAN-45151OPT. BAY Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4515/Opt. Bay Date..02/25/08 16:46:34 Project Address.. ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I I 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 I I (951) 739-9501 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T_4515OB Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- ---------------------------- ---------------------------- MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) _----------------------- ---------- Design Design -------------------- Margin = - = Space Heating.......... 2.31 2.06 0.25 = - Space Cooling.......... 79.08 60.55 18.53 = = Water Heating.......... 12.33 11.29 1.04 = = North Total 93.72 73.90 19.82 = = Space Heating.......... 2.31 2.26 0.05 = - Space Cooling.......... 79.08 61.00 18.08 = = Water Heating.......... 12.33 11.29 1.04 = = East Total 93.72 74.55 19.17 = = Space Heating.......... 2.31 2.46 -0.15 = = Space Cooling.......... 79.08 60.47 18.61 = = Water - Heating.......... 12.33 11.29 1.04 = - = South Total -------- 93.72 ---------------- 74.22 19.50 = - Space Heating.......... 2.31 2.18 0.13 = = Space Cooling.......... 79.08 59.42 19.66 = = Water Heating.......... 12.33 11.29 1.04 = = West Total 93.72 72.89 20.83 = _ *** Building complies with Computer Performance _ *** HERS Verification ----------------------------------------------------------------- ----------------------------------------------------------------- Required for Compliance CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 Project Title.......... Plan 4515/Opt. Bay Date..02/25/08 16:46:34 MICROPAS7 v7.10 File-T_4515OB Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 1773 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 17878 cf 1773 sf 20.8 % of floor area 0.34 Btu/hr-sf-F 0.31 10.1 ft BUILDING ZONE INFORMATION ------------------------- Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ----- ------------- ----- ------- ---------- Residence 1773 17878 1.00 4.0 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 1 Wall ----- Wood ---- 291 ----------- 0.102 13 ----- 0 --- 180 ---- 90 --- Yes --------- IV.9 A3 -------------- SOUTH 2 Wall Wood 523 0.102 13 0 270 90 Yes IV.9 A3 WEST 3 Wall Wood 158 0.102 13 0 0 90 Yes IV.9 A3 NORTH 4 Wall Wood 570 0.102 13 0 90 90 Yes IV.9 A3 EAST 5 Wall Wood 214 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 6 RoofRad Wood 1773 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 7 Door Wood 24 0.387 0 0 0 90 Yes None Wood Door 8 Door Wood 18 0.387 0 0 0 90 No None Wood Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4515/Opt. Bay Date..02/25/08 16:46:34 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T_4515OB Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------ PERIMETER LOSSES ---------------- Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ 9 S1abEdge ------ 192 -------- 0.900 ------- R-0 ----- No --------- None ---------------------- To Outside 10 SlabEdge 23 0.550 R-0 No None TO GARAGE FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ 1 Wind Back (S) ----- 12.0 ----- 0.340 ----- 0.300 --- 180 ---- 90 -------- Standard ------------------------ SGLASSI/Vinyl/Operable W 2 Wind Back (S) 24.0 0.340 0.330 180 90 Standard SGLASS2/Vinyl/Fixed Wind 3 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS3/Vinyl/Operable W 4 Wind Back (S) 18.0 0.340 0.300 180 90 Standard SGLASS4/Vinyl/Operable W 5 Wind Back (S) 36.0 0.340 0.330 180 90 Standard SGLASSS/Vinyl/Fixed Wind 6 Wind Back (S) 18.0 0.340 0.300 180 90 Standard SGLASS6/Vinyl/Operable W 7 Door Back (S) 42.7 0.340 0.310 180 90 Standard SGLASSI/French Door ,8 Door Right (W) 48.0 0.340 0.310 270 90 Standard WGLASSI/Vinyl/Sliding G1 9 Wind Right (W) 4.0 0.340 0.330 270 90 Standard WGLASS2/Vinyl/Fixed Wind 10 Wind Right (W) 4.0 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind 11 Wind Right (W) 6.0 0.340 0.300 270 90 Standard WGLASS4/Vinyl/Operable W 12 Wind Right (W) 6.0 0.340 0.330 270 90 Standard WGLASSS/Vinyl/Fixed Wind 13 Wind Right (W) 18.0 0.340 0.300 270 90 Standard WGLASS6/Vinyl/Operable W 14 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASSI/Vinyl/Operable W 15 Wind Front (N) 6.0 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind 16 Wind Front (N) 26.0 0.340 0.300 0 90 Standard NGLASS3/Vinyl/Operable W 17 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W 18 Wind Left (E) 6.0 0.340 0.300 90 90 Standard EGLASS2/Vinyl/Operable W 19 Wind Left (E) 10.0 0.340 0.300 90 90 Standard EGLASS3/Vinyl/Operable W 20 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W 21 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASSS/Vinyl/Operable W OVERHANGS -Window--- ------------ Overhang ------------ Area Left Right Surface (sf) Width Height.Depth Height Extension Extension ----------- 4 Window ----- 18.0 ----- 3.00 ------ 6.00 ----- 7.00 ------ 0.50 --------- n/a --------- n/a 5 Window 36.0 6.00 6.00 7.00 0.50 n/a n/a 6 Window 18.0 3.00 6.00 7.00 0.50 n/a n/a 7 Door 42.7 5.33 8.00 7.00 0.50 n/a n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4515/Opt. Bay Date..02/25/08 16:46:34 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T_4515OB Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- 8 Door ----- 48.0 ----- 6.00 ------ 8.00 ----- 7.00 ------ 0.50 --------- n/a --------- n/a 13 Window 18.0 3.00 6.00 7.00 0.50 n/a n/a 15 Window 6.0 1.00 6.00 7.00 0.50 n/a n/a 17 Window 18.0 3.00 6.00 7.00 0.50 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ Standard Slab 1773 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type Systems Efficiency EER or TXV Airflow Draw Capacity ------------ Furnace ------- 1 ----------- ----- 0.800 AFUE n/a ------------- n/a -------- n/a -------- n/a -------- n/a ACSplit 1 14.00 SEER 11.5 Yes No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- Furnace 36868 n/a n/a n/a ACSplit n/a 27545 34183 n/a Orientation of Maximum..... Sizing Location............ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range ............... Front Facing 0 deg (N) LA QUINTA 26 F 70 F 111 F 75 F 34 F CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4515/Opt. Bay Date..02/25/08 16:46:34 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T_4515OB Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location ----------- R-value ------- Leakage ------- Area -------- Ducts --------- Furnace Attic R-6 Yes No No ACSplit. Attic R-6 Yes No No WATER HEATING SYSTEMS --------------------- Number Tank External Heater in Energy Size Insulation Tank Type Type ------------------------ Distribution Type ------------------- System ------ Factor -------- (gal) ------ R-value ---------- 1 Storage Gas Standard 1 0.62 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 6 Project Title.......... Plan 4515/Opt. Bay Date..02/25/08 16:46:34 I MICROPAS7 v7.10 File-T_4515OB Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION -------------------------- This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested -Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4515/Opt. Bay Date..02/25/08 16:46:34 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T_4515OB Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER Name.... Kyle Tibbitts Name.... Company. Shea Homes/Trilogy Company. Address. 60946 Desert Rose Address. La Quinta, CA 92253 Phone... (760) 777-6026 Phone... License. Zz�rj Signed.. `l d2Signed.. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Chinh Nguyen Westpac Air Conditioning, Inc. 1610 N. Maple St. Corona, CA 92880 (951) 739-9501 / (dat ) MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 1 Project Title.......... Plan 4515/Opt. Bay Date..02/25/08 16:46:34 Project Address........ ******* La Quinta, CA *v7.10* Documentation Author... Chinh Nguyen ******* Westpac Air Conditioning, Inc. 1610 N. Maple St. Corona, CA 92880 (951) 739-9501 Building Permit # Plan Check / Date Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. I MICROPAS7 v7.10 File-T_4515OB Wth-CTZ15S05 Program -FORM MF-lR I User#=MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling 150(b): Loose fill insulation manufacturer's labeled R-Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox / b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch / 118: Insulation specified or installed meets insulation qualit standards. Indicate type and include CF-6R form G 116-17: Fenestration Products, Exterior Doors and Infiltration?' Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 2 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4515/Opt. Bay Date..02/25/08 16:46:34 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T_45150B Wth-CTZ15S05 Program -FORM MF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En- sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance / with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A z 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space j 7. Solar water -heating systems/collectors are certified by the, Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR ------------------------------------------------------------------------------- Page 3 ------------------------------------------------------------------------------- Project Title.......... Plan 4515/Opt. Bay Date..02/25/08 16:46:34 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T_4515OB Wth-CTZ15S05 Program -FORM MF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic / and either mesh or tape shall be used 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause / reductions in the cross -sectional area of the ducts / 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with / mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers / 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating / b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances / with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 4 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 4515/Opt. Bay Date..02/25/08 16:46:34 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T_4515OB Wth-CTZ15S05 Program -FORM MF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-1 I ------------------------------------------------------------------------------- and have an output frequency no less than 20 kHz 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast _ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires % 150(k)3: Permanently installed luminaires in bathrooms, T garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d)