Trilogy TR 30023 (Product 3) 2007 Code Update - Title 24TITLE 24
Energy Conservation
Compliance Report
MAR 2 0 2008 J
By
TRILOGY AT LA QUINTA
La Quinta, California
F-R-O--D'UCT--3
Prepared For
SHEA HOMES
60946 Desert Rose
La Quinta, CA 92253
Phone: (760) 777-6026
Date :Feb 26th, 2008
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
x^KNA%y km Oka- Ww or PA -I&
EXTINDACA
AIR CONDITIONING
i
Working As Team to Be The Best In Our Industry"
Chinh Nguyen, Certified Energy Analyst
1610 N. Maple Street
Corona, CA 92880-1760
(800) 700-0799 / (951) 739-9509 fax
E-mail. chinh.nouven(EDwestpacair.com
Table of Contents 11
-Cover Sheet
-T-24 Summary report
-Plan 6505
- CF-1 R Certificate of Compliance
- MF-1 R Mandatory Measures Check List
- Plan 6505/option Bay 2
- CF-1 R Certificate of Compliance
- MF-1 R Mandatory Measures Check List
- Plan 6505/option Bay 2/Casita
- CF-I R Certificate of Compliance
- MF-1 R Mandatory Measures Check List
- Plan 6420
- CF-1 R / Certificate of Compliance
- MF-1R Mandatory Measures Check List
- Plan 6420/Option Bay 2
- CF-1 R / Certificate of Compliance
- MF-1 R Mandatory Measures Check List
- Plan 6420/Option Bay 2/Casita
- CF-1 R / Certificate of Compliance
- MF-1 R Mandatory Measures Check List
- Plan 6430
- CF-1 R / Certificate of Compliance
- MF-1 R Mandatory Measures Check List
t
TITLE-24 SUMMARY REPORT
The Following is the requirement to exceed the 2005 Residential Energy
Standards (California Code of Regulations, Title 24, Part 6 and the
Administrative Regulations, Title 24, Part 1) 15%
1. R-38 Roof Insulation.
2. Radiant Barrier is Required.
3. R-13 Exterior Wall Insulation.
4. Low-e Vinyl Windows & Sliding Doors to be selected by Owner:
-Operable Windows with U value of 0.34 & SHGC of 0.30
-Fixed Windows with U value of 0.34 & SHGC of 0.33
-Sliding Glasses Door with U value of 0.34 & SHGC of 0.31
5. R-6.0 Duct Insulation.
6. Gas Furnace with 80% AFUE .
7. Condenser 14.0 SEER With Minimum EER of 11.5
8. TXV Required.
9. 50 Gallons Water Heater to be selected by Owner.
IO.Ducts Tested Required.
I I.Quality Insulation Installation is Required.
SHEA HOMES,
PRODUCT-3
TRILOGY AT LA QUINTA
PLAN -6505
Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509
I
CERTIFICATE -OF- COMPLIANCE: -RESIDENTIAL -COMPUTER -METHOD
----------CF-1R---- Page -1
------------
Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09
Project Address........ ******* ---------------------
La Quinta, CA *v7.10* II
Documentation Author... Chinh Nguyen ******* I Building Permit # I
Westpac Air Conditioning, Inc. I I
1610 N. Maple St. I Plan Check / Date
Corona, CA 92880 I
(951) 739-9501 I Field Check/ Date I
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM CF-1R I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta. P-3 I
-------------------------------------------------------------------------------
MICROPAS7 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed Compliance =
_ (kTDV/sf-yr)
_-----------------------
----------
Design
Design
--------------------
Margin =
-
- Space
Heating..........
2.34
2.14
0.20 =
- Space
Cooling..........
76.41
61.52
14.89 =
= Water
Heating..........
10.48
9.68
0.80 =
=
North Total
89.23
73.34
15.89 =
- Space
Heating..........
2.34
2.51
-0.17 =
= Space
Cooling..........
76.41
61.98
14.43 =
= Water
Heating..........
10.48
9.68
0.8.0 =
=
East Total
89.23
74.17
15.06 =
- Space
Heating..........
2.34
2.97
-0.63 =
- Space
Cooling..........
76.41
60.32
16.09 -
= Water
Heating..........
10.48
9.68
0.80 -
=
South Total
89.23
72.97
16.26 =
= Space
Heating..........
2.34
2.54
-0.20 =
= Space
Cooling..........
76.41
59.28
17.13 =
= Water
_
Heating..........
10.48
9.68
0.80 =
=
West Total
--------
89.23
----------------
71.50
-
17.73 =
_ ***
Building complies
with Computer Performance
_
*** HERS Verification
Required
for Compliance
*** _
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2
-- ---------------------------
Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM CF-1R I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
GENERAL INFORMATION
HERS Verification.......... Required
Conditioned Floor Area..... 2398 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Fuel Type ................. NaturalGas
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... FullYear
Floor Construction Type.... Slab On Grade
Number of Building Zones... 1
Conditioned Volume......... 23980 cf
Slab -On -Grade Area......... 2398 sf
Glazing Percentage......... 27.1 % of floor area
Average Glazing U-factor... 0.34 Btu/hr-sf-F
Average Glazing SHGC....... 0.31
Average Ceiling Height..... 10 ft
BUILDING ZONE INFORMATION
-------------------------
.Floor # of # of Cond- Thermo- Vent Vent Verified
Area Volume Dwell Peop- it- stat Height Area Leakage or
Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap
-------------- ----- ------ ----- ----- ------------- ----- ------- ----------
Residence 2398 23980 1.00 4.0 Yes Setback 2.0 Standard No
OPAQUE SURFACES
U-
Sheath-
Solar
Appendix
Frame
Area
fact-
Cavity
ing
Act
Gains
IV
Location/
Surface
Type
(sf)
or
R-val
R-val
Azm
Tilt
Reference
Comments
------------
1
Wall
-----
Wood
----
344
-----
0.102
-----
13
-----
0
---
180
----
90
---
Yes
---------
IV.9
A3
--------------
SOUTH
2
Wall
Wood
376
0.102
13
0
270
90
Yes
IV.9
A3
WEST
3
Wall
Wood
212
0.102
13
0
0
90
Yes
IV.9
A3
NORTH
4
Wall
Wood
572
0.102
13
0
90
90
Yes
IV.9
A3
EAST
5
Wall
Wood
13
0.102
13
0
135
90
Yes
IV.9
A3
SOUTHEAST
6
Wall
Wood
13
0.102
13
0
225
90
Yes
IV.9
A3
SOUTHWEST
7
Wall
Wood
562
0.102
13
0
0
90
No
IV.9
A3
GARAGE WALL
8
RoofRad
Wood
2398
0.025
38
0
n/a
0
Yes
IV.1
A18
Attic
9
Door
Wood
20
0.387
0
0
0
90
Yes
None
Wood Door
10
Door
Wood
18
0.387
0
0
0
90
No
None
Wood Door
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3
Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09
MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM CF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
PERIMETER LOSSES
----------------
Appendix
Length F2 Insul Solar IV Location/
Surface (ft) Factor R-val Gains Reference Comments
------------ --------------------- -------------- ----------------------
11 S1abEdge 220 0.900 R-0 No None To Outside
12 SlabEdge 58 0.550 R-0 No None TO GARAGE
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
------------------ ----- ----- ----- --- ------------ ------------------------
1 Wind Back (S) 12.0 0.340 0.330 180 90 Standard SGLASSI/Vinyl/Fixed Wind
2 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS2/French Door
3 Wind Back (S) 12.0 0.340 0.330 180 90 Standard SGLASS3/Vinyl/Fixed Wind
4 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS4/Vinyl/Operable W
5 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS5/Vinyl/Sliding G1
6 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS6/Vinyl/Operable W
7 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS7/Vinyl/Sliding Gl
8 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS8/Vinyl/Operable W
9 Wind Right (W) 48.0 0.340 0.300 270 90 Standard WGLASSI/Vinyl/Operable W
10 Wind Right (W) 48.0 0.340 0.300 270 90 Standard WGLASS2/Vinyl/Operable W
11 Wind Right (W) 24.0 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind
12 Wind Right (W) 24.0 0.340 0.330 270 90 Standard WGLASS4/Vinyl/Fixed Wind
13 Wind Front (N) 6.0 0.340 0.330 0 90 Standard NGLASSI/Vinyl/Fixed Wind
14 Wind Front (N) 6.0 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind
15 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS3/Vinyl/Operable W
16 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W
17 Wind Left (E) 48.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W
18 Wind Left (E) 6.0 0.340 0.300 90 90 Standard EGLASS2/Vinyl/Operable W
19 Wind Left (E) 4.0 0.340 0.330 90 90 Standard EGLASS3/Vinyl/Fixed Wind
20 Wind Left (E) 10.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W
21 Wind Left (E) 20.0 0.340 0.330 90 90 Standard SGLASS5/Vinyl/Fixed Wind
22 Wind Left (E) 10.0 0.340 0.300 90 90 Standard EGLASS6/Vinyl/Operable W
23 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS7/Vinyl/Operable W
24 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS8/Vinyl/Operable W
25 Wind Left (E) 36.0 0.340 0.300 90 90 Standard EGLASS9/Vinyl/Operable W
26 Wind Left (SE) 12.0 0.340 0.330 135 90 Standard SEGLASSI/Vinyl/Fixed Win
27 Wind Back (SW) 12.0 0.340 0.330 225 90 Standard SWGLASSI/Vinyl/Fixed Win
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4
-------------------------------------------------------------------------------
Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM CF-1R I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
OVERHANGS
---Window---
------------
Overhang ------------
Area
Left
Right
Surface
-----------
(sf)
Width
Height
Depth
Height
Extension
Extension
4
Window
-----
36.0
-----
6.00
------
8.00
-----
10.0
------
0.25
---------
n/a
---------
n/a
5
Door
48.0
6.00
8.00
10.0
0.25
n/a
n/a
7
Door
48.0
6.00
8.00
10.0
0.25
n/a
n/a
8
Window
36.0
6.00
8.00
10.0
0.25
n/a
n/a
9
Window
48.0
6.00
8.00
10.0
0.25
n/a
n/a
10
Window
48.0
6.00
8.00
10.0
0.25
n/a
n/a
13
Window
6.0
1.00
6.00
7.00
0.25
n/a
n/a
14
Window
6.0
1.00
6.00
7.00
0.25
n/a
n/a
17
Window
48.0
6.00
8.00
7.00
0.25
n/a
n/a
25
Window
36.0
6.00
8.00
10.0
0.25
n/a
n/a
SLAB SURFACES
-------------
Area
Slab Type (sf)
Standard Slab 2398
HVAC SYSTEMS
------------
Verified
Number
Verified
Verified
Verified
Verified
Maximum
System
of
Minimum
Refrig Charge
Adequate
Fan Watt
Cooling
Type
Systems
Efficiency EER
or TXV
Airflow
Draw
Capacity
------------
Furnace
-------
1
----------- -----
0.800 AFUE n/a
-------------
n/a
--------
n/a
--------
n/a
--------
n/a
ACSplit
1
14.00 SEER 11.5
Yes
No
No
No
HVAC SIZING
Verified
Total
Sensible
Design
Maximum
Heating
Cooling
Cooling
Cooling
System
Load
Load
Capacity
Capacity
Type
-------------
(Btu/hr)
----------
(Btu/hr)
----------
(Btu/hr)
----------
(Btu/hr)
----------
Furnace
49503
n/a
n/a
n/a
ACSplit
n/a
39379
48870
n/a
Orientation of.Maximum..... Front Facing 180 deg (S)
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5
Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM CF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
Sizing Location.._ ........ LA QUINTA
Winter Outside Design...... 26 F
Winter Inside Design....... 70 F
Summer Outside Design...... 111 F
Summer Inside Design....... 75 F
Summer Range ............... 34 F
DUCT SYSTEMS
Verified Verified Verified
System Duct Duct Duct Surface Buried
Type Location R-value Leakage Area Ducts
------------- ----------- ------ ------- -------- ---------
Furnace Attic R-6 Yes No No
ACSplit Attic R-6 Yes No No
WATER HEATING SYSTEMS
---------------------
Number Tank External
Heater in Energy Size Insulation
Tank Type Type Distribution Type System Factor (gal) R-value
------------------------------------------- -------------- ----------------
1 Storage Gas Standard 1 0.62 50 R- n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates HERS verified Insulation Installation.
This building incorporates a HERS verified Refrigerant Charge test
or a HERS verified Thermostatic Expansion Valve (TXV). If a
cooling system is not installed, then HERS verification is not necessary.
This building. incorporates HERS verified EER.
This building incorporates HERS verified Duct Leakage.
This is a multiple orientation building. This printout is for the front
facing North.
This building incorporates a Radiant Barrier.
CERTIFICATE -OF- COMPLIANCE: -RESIDENTIAL -COMPUTER -METHOD
----------CF-lR---- Page -6
Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09
MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM CF-lR
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
------------------ ------------------------------------------------------------
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-4R installation certificate. ***
This building incorporates HERS verified Insulation Installation.
This building incorporates a HERS verified Refrigerant Charge test
or a HERS verified Thermostatic Expansion Valve (TXV). If a
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified EER.
This building incorporates HERS verified Duct Leakage. Target leakage is
calculated and documented on the CF-4R. If the measured CFM is above the
target, then corrective action must be taken to reduce the duct leakage and
then must be retested. Alternatively, the compliance calculations could be
redone without duct testing. If ducts are not installed, then HERS
verification is not necessary.
REMARKS
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7
Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM CF-lR
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title-24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility.
DESIGNER or OWNER
Name.... Kyle Tibbitts
Company. Shea Homes/Trilogy
Address. 60946 Desert Rose
La Quinta, CA 92253
Phone... (7�� 27�g�026
License.
Signed.. 41��t S -'�-o 9
(date)
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed..
(date)
Name....
Company.
Address.
Phone...
Signed..
DOCUMENTATION AUTHOR
Chinh Nguyen
Westpac Air Conditioning,
1610 N. Maple St.
Corona, CA 92880
(951) 739-9501
ate)
Inc.
MANDATORY MEASURES CHECKLIST: RESIDENTIAL
-------------------------------------------------------------------------------
MF-1R
Page 1
Project Title..........
Plan 6505 Standard
Date..02/27/08 10:39:09
Project Address........
******* ---------------------
La Quinta, CA
*v7.10* I
I
Documentation Author...
Chinh Nguyen
******* I Building Permit # I
Westpac Air Conditioning,
Inc.
1
1610 N. Maple St.
I Plan Check /
Date I
Corona, CA 92880
I
1
(951) 739-9501
1 Field Check/
Date
Climate Zone...........
15
---------------------
Compliance Method......
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 for 2005
Standards by Enercomp,
Inc.
1 MICROPAS7 v7.10
File-TRI_6505 Wth-CTZ15S05
Program -FORM MF-1R
1
1 User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta
-------------------------------------------------------------------------------
P-3 I
Note: Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supersede the items marked with
an asterisk (*). When this checklist is incorporated into the permit documents,
the features noted shall be considered by all parties as minimum component
performance specifications for the mandatory measures whether they are shown
elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES De- En-
sign- force-
n/a er ment
*150(a): Minimum R-19 insulation in wood framed ceiling or
equivalent U-factor in metal frame ceiling
150(b): Loose fill insulation manufacturer's labeled R-Value _
*150(c): Minimum R-13 wall insulation in wood framed walls or
equivalent U-factor in metal frame walls (does not apply
to exterior mass walls) D rl3
*150(d): Minimum R-13 raised floor insulation in framed floors
or equivalent U-factor
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door covering the entire
/
opening of the firebox
b. Outside air intake with damper and control, flue
/
damper and control
2. No continuous burning gas pilot lights allowed
150(f): Air retarding wrap installed to comply with Sec. 151
meets requirements specified in ACM Residential Manual
150(g): Vapor barriers mandatory in Climate Zones 14,16 only
150(1): Slab edge insulation - water absorption rate for the
insulation material without facings no greater than 0.3%,
water vapor permeance rate no greater than 2.0 perm/inch
118: Insulation specified or installed meets insulation quality
standards. Indicate type and include CF-6R form
��
116-17: Fenestration Products, Exterior Doors and Infiltration?
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage
2. Fenestration products (except field -fabricated) have
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 2
-------------------------------------------------------------------------------
Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM MF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3
-------------------------------------------------------------------------------
label with certified U-factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
De- En-
sign- force
n/a
er ment
110-113: HVAC equipment, water heaters, showerheads and
faucets certified by the Energy Commission
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA
150(i): Setback thermostat on all applicable heating and/or
/
cooling systems
150(j): Water system pipe and tank insulation and cooling
systems line insulation
1. Storage gas water heaters rated with an Energy Factor
less than 0.58 must be externally wrapped with insulation
having an installed thermal resistance of R12 or greater
2. Back-up tanks for solar system, unfired storage tanks, or
other indirect hot water tanks have R-12 external
insulation or R-16 internal and indicated on the
exterior of the tank showing the R-value
3. The following piping is insulated according to Table 150-A/B
or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to
water heater tank, non -recirculating systems, and
entire length of recirculating sections of hot water
pipes shall be insulated to Table 150B
2. Cooling system piping (suction, chilled water, or
brine lines), piping insulated between heating source
and indirect hot water tank shall be insulated to
Table 150-B and Equation 150-A
4. Steam hydronic heating systems or hot water systems >15 psi,
meet requirements of Table 123-A
5. Insulation must be protected from damage, including that due
to sunlight, moisture, equipment maintenance and wind
6. Insulation for chilled water piping and refrigerant suction
-;7,-
piping includes a vapor retardant or is enclosed entirely
in conditioned space
7. Solar water -heating systems/collectors are certified by t
Solar Rating and Certification Corporation
*150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to
meet the requirements of the CMC Sections 601, 602, 603,
604, 605 and Standard 6-5; supply -air and return -air ducts
and plenums are insulated to a minimum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings
shall be sealed with mastic, tape, or other duct -closure
system that meets the applicable requirements of UL 181,
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 3
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09
----------------------------------------------------------------=--------------
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM MF-1R I
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
UL 181A, or UL 181B or aerosol sealant that meets the
requirements of UL 723. If mastic or tape is used to seal
openings greater than 1/4 inch, the combination of mastic
and either mesh or tape shall be used
2.
Building cavities, support platforms for air handlers, and
plenums defined or constructed with materials other than
sealed sheet metal, duct board or flexible duct shall not
be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in
cavities and support platforms shall not be compressed to cause
reductions in the cross -sectional area of the ducts
3.
Joints and seams of duct systems and their components
_
shall not be sealed with cloth backed rubber adhesive
duct tapes unless such tape is used in combination with
mastic and draw bands
4.
Exhaust fan systems have back draft or automatic dampers
—
5.
Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
/
operated dampers
_
6.
Protection of Insulation. Insulation shall be protected
from damage due to sunlight, moisture, equipment mainten-
ance and wind. Cellular foam insulation shall be protected
as above or painted with a coating that is water retardant
and provides shielding from solar radiation that can cause
degradation of the material
7.
Flexible ducts cannot have porous inner cores
_
114:
Pool and Spa Heating Systems and Equipment
1.
A thermal efficiency that complies with the Appliance
Efficiency Regulations, on -off switch mounted outside of
the heater, weatherproof operating instructions no
electric resistance heating and no pilot light
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for future solar heating `
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch /
115: Gas -fired central furnaces, pool heaters, spa heaters or /
household cooking appliances have no continuously burning
pilot light (Exception: Non -electrical cooking appliances
with pilot < 150 Btu/hr)
118(i): Cool Roof material meets specified criteria
RESIDENTIAL LIGHTING MEASURES De- En-
sign- force
n/a er ment
150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID:
contain only high efficacy lamps as outlined in Table
150-C, and do not contain a medium screw base socket
(E24/E26). Ballast for lamps 13 watts or greater are electronic
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 4
Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM MF-1R
I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-----------------------------------------------------------------'
and have an output frequency no less than 20 kHz
-----
150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain
only high efficacy lamps as outlined in Table 150-C,
luminaire has factory installed HID ballast
150(k)2: Permanently installed luminaires in kitchens shall
be high efficacy luminaires. Up to 50 percent of the wattage,
as determined in Sec. 130(c), of permanently installed luminaires
in kitchens may be in luminaires that are not high efficacy
luminaires, provided that these luminaires are controlled
by switches separate from those controlling the high
efficacy luminaires
150(k)3: Permanently installed luminaires in bathrooms,
garages, laundry rooms, utility rooms shall be high
efficacy luminaires OR are controlled by an occupant
sensor(s) certified to comply with Section 119(d) that
does not turn on automatically or have an always on option
150(k)4: Permanently installed luminaires located other than
in kitchens, bathrooms, garages, laundry rooms, and utility
rooms shall be high efficacy luminaires (except closets
less than 70 ft2), OR are controlled by a dimmer switch
OR are controlled by an occupant sensor(s) that complies
with Section 119(d) that does not turn on automatically
or have an always on option
/
150(k)5: Luminaires that are recessed into insulated ceilings
are approved for zero clearance insulation cover (IC) and
are certified air tight to ASTM E283 and labeled as air
/
tight (AT) to less than 2.0 CFM at 75 Pascals
150(k)6: Luminaires providing outdoor lighting and permanently
mounted to a residential building or to other buildings on
the same lot shall be high efficacy luminaires (not in-
cluding lighting around swimming pools/water features or
other Article 680 locations) OR are controlled by occupant
sensors with integral photo control certified to comply
/
with Section 119(d)
150(k)7: Lighting for parking lots for 8 or more vehicles shall
have lighting that complies with Sec. 130, 132, and 147.
Lighting for parking garages for 8 or more vehicles shall
have lighting that complies with Sec. 130, 131, and 146
150(k)8: Permanently installed lighting in the enclosed, non -
dwelling spaces of low-rise residential buildings with four
or more dwelling units shall be high efficacy luminaires OR
are controlled by an occupant sensor(s) certified to
comply with Section 119(d)
SHEA HOMES
PRODUCT-3
TRILOGY AT LA QUINTA
PLAN -6505/OPT. BAY 2
Chinh Nguyen, Certified Enery Analyst ♦ (951) 739-9501 / (951) 739-9509
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1
-------------------------------------------------------------------------------
Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06
Project Address........ ******* ---------------------
La Quinta, CA *v7.10* I I
Documentation Author... Chinh Nguyen ******* I Building Permit # I
Westpac Air Conditioning, Inc. I I
1610 N. Maple St. I Plan Check / Date I
Corona, CA 92880 I I
(951) 739-9501 I Field Check/ Date
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM CF-lR I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
-----------------------------------------------------------------
-----------------------------------------------------------------
=
MICROPAS7
ENERGY USE
SUMMARY
=
= Energy
----------------------------
Use
Standard
Proposed Compliance =
_ (kTDV/sf-yr)
_-----------------------
----------
Design
Design
--------------------
Margin =
-
- Space
Heating..........
2.31
2.11
0.20 =
- Space
Cooling..........
76.07
61.10
14.97 =
= Water
Heating..........
10.43
9.63
0.80 =
=
North Total
88.81
72.84
15.97 =
- Space
Heating..........
2.31
2.42
-0.11 =
e - Space
Cooling..........
76.07
61.51
14.56 =
= Water
_
Heating..........
10.43
9.63
0.80 =
-
=
East Total
--------
88.81
----------------
73.56
15.25 =
= Space
Heating..........
2.31
2.91
-0.60 =
- Space
Cooling..........
76.07
60.11
15.96 =
= Water
Heating..........
10.43
9.63
0.80 =
=
South Total
88.81
72.65
16.16 =
= Space
Heating..........
2.31
2.51
-0.20 =
= Space
Cooling..........
76.07
58.73
17.34 =
= Water
_
Heating..........
10.43
--------
9.63
0.80 =
-
=
West Total
88.81
----------------
70.87
17.94 =
_ ***
Building complies
with Computer
Performance
_ *** HERS Verification
Required
for Compliance
*** _
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2
Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06
MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM CF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
GENERAL INFORMATION
HERS Verification.......... Required
Conditioned Floor Area..... 2424 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Fuel Type ................. NaturalGas
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... FullYear
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U-factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Slab On Grade
1
24240 cf
2424 sf
26.8 % of floor area
0.34 Btu/hr-sf-F
0.31
10 ft
BUILDING ZONE
INFORMATION
Floor
-------------------------
# of
# of
Cond-
Thermo-
Vent
Vent Verified
Area
Volume Dwell
Peop-
it-
stat
Height
Area Leakage or
Zone Type (sf)
-------------- -----
(cf) Units
------ -----
le
-----
ioned
-----
Type
--------
(ft)
-----
(sf) Housewrap
------- ----------
Residence 2424
24240 1.00
4.0
Yes
Setback
2.0
Standard No
OPAQUE SURFACES
U-
Sheath-
Solar
Appendix
Frame
Area
fact-
Cavity
ing
Act
Gains
IV
Location/
Surface
Type
(sf)
or
R-val
R-val
Azm
Tilt
Reference
Comments
------------
1
Wall
-----
Wood
----
344
-----
0.102
-----
13
-----
0
---
180
----
90
---
Yes
---------
IV.9
A3
--------------
SOUTH
2
Wall
Wood
376
0.102
13
0
270
90
Yes
IV.9
A3
WEST
3
Wall
Wood
212
0.102
13
0
0
90
Yes
IV.9
A3
NORTH
4
Wall
Wood
572
0.102
13
0
90
90
Yes
IV.9
A3
EAST
5
Wall
Wood
13
0.102
13
0
135
90
Yes
IV.9
A3
SOUTHEAST
6
Wall
Wood
13
0.102
13
0
225
90
Yes
IV.9
A3
SOUTHWEST
7
Wall
Wood
562
0.102
13
0
0
90
No
IV.9
A3
GARAGE WALL
8
RoofRad
Wood
2398
0.025
38
0
n/a
0
Yes
IV.1
A18
Attic
9
Door
Wood
20
0.387
0
0
0
90
Yes
None
Wood Door
10
Door
Wood
18
0.387
0
0
0
90
No
None
Wood Door
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM CF-lR
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
PERIMETER LOSSES
----------------
Appendix
Length
F2
Insul
Solar
IV
Location/
Surface
(ft)
Factor
R-val
Gains
Reference
Comments
------------
11 S1abEdge
------
220
--------
0.900
-------
R-0
-----
No
---------
None
----------------------
To Outside
12 SlabEdge
58
0.550
R-0
No
None
TO GARAGE
FENESTRATION SURFACES
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
------------------ ----- ----- ----- --- ------------ ------------------------
1 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASSI/Vinyl/Operable W
2 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS2/French Door
3 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS3/Vinyl/Operable W
4 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS4/Vinyl/Operable W
5 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS5/Vinyl/Sliding Gl
6 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS6/Vinyl/Operable W
7 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS7/Vinyl/Sliding G1
8 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS8/Vinyl/Operable W
9 Wind Right (W) 48.0 0.340 0.300 270 90 Standard WGLASSI/Vinyl/Operable W
10 Wind Right (W) 48.0 0.340 0.300 270 90 Standard WGLASS2/Vinyl/Operable W
11 Wind Right (W) 24.0 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind
12 Wind Right (W) 24.0 0.340 0.330 270 90 Standard WGLASS4/Vinyl/Fixed Wind
13 Wind Front (N) 6.0 0.340 0.330 0 90 Standard NGLASSI/Vinyl/Fixed Wind
14 Wind Front (N) 6.0 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind
15 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS3/Vinyl/Operable W
16 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W
17 Wind Left (E) 48.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W
18 Wind Left (E) 6.0 0.340 0.300 90 90 Standard EGLASS2/Vinyl/Operable W
19 Wind Left (E) 4.0 0.340 0.330 90 90 Standard EGLASS3/Vinyl/Fixed Wind
20 Wind Left (E) 10.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W
21 Wind Left (E) 20.0 0.340 0.330 90 90 Standard EGLASS5/Vinyl/Fixed Wind
22 Wind Left (E) 10.0 0.340 0.300 90 90 Standard EGLASS6/Vinyl/Operable W
23 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS7/Vinyl/Operable W
24 Wind Left (E) 12.0 0.340 0.300 90 90 Standard SGLASS8/Vinyl/Operable W
25 Wind Left (E) 36.0 0.340 0.300 90 90 Standard EGLASS9/Vinyl/Operable W
26 Wind Left (SE) 12.0 0.340 0.330 135 90 Standard SEGLASSI/Vinyl/Fixed Win
27 Wind Back (SW) 12.0 0.340 0.330 225 90 Standard SWGLASSI/Vinyl/Fixed Win
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4
-------------------------------------------------------------------------------
Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06
I MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM CF-lR I
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
OVERHANGS
---Window---
------------
Overhang ------------
Area
Left
Right
Surface
(sf)
Width
Height
Depth
Height
Extension
Extension
-----------
4
Window
-----
36.0
-----
6.00
------
8.00
-----
10.0
------
0.25
---------
n/a
---------
n/a
5
Door
48.0
6.00
8.00
10.0
0.25
n/a
n/a
7
Door
48.0
6.00
8.00
10.0
0.25
n/a
n/a
8
Window
36.0
6.00
8.00
10.0
0.25
n/a
n/a
9
Window
48.0
6.00
8.00
10.0
0.25
n/a
n/a
10
Window
48.0
6.00
8.00
10.0
0.25
n/a
n/a
13
Window
6.0
1.00
6.00
6.00
0.25
n/a
n/a
14
Window
6.0
1.00
6.00
6.00
0.25
n/a
n/a
17
Window
48.0
6.00
8.00
4.00
0.25
n/a
n/a
25
Window
36.0
6.00
8.00
10.0
0.25
n/a
n/a
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
Standard Slab 2424
HVAC SYSTEMS
------------
Verified
Number
Verified Verified
Verified
Verified
Maximum
System
of
Minimum Refrig Charge
Adequate
Fan Watt
Cooling
Type
Systems
Efficiency EER or TXV
-----------
Airflow
Draw
Capacity
------------
Furnace
-------
1
----- -------------
0.800 AFUE n/a n/a
--------
n/a
--------
n/a
-------
n/a
ACSplit
1
14.00 SEER 11.5 Yes
No
No
No
HVAC SIZING
Verified
Total
Sensible
Design
Maximum
Heating
Cooling
Cooling
Cooling
System
Load
Load
Capacity
Capacity
Type
-------------
(Btu/hr)
----------
(Btu/hr)
----------
(Btu/hr)
----------
(Btu/hr)
----------
Furnace
49616
n/a
n/a
n/a
ACSplit
n/a
39701
49268
n/a
Orientation of Maximum..... Front Facing 180 deg (S)
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM CF-lR
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
Sizing Location............ LA QUINTA
Winter Outside Design...... 26 F
Winter Inside Design....... 70 F
Summer Outside Design...... 111 F
Summer Inside Design....... 75 F
Summer Range ............... 34 F
DUCT SYSTEMS
------------
Verified Verified Verified
System Duct Duct Duct Surface Buried
Type Location R-value Leakage Area Ducts
-------------------------------------------------------
Furnace Attic R-6 Yes No No
ACSplit Attic R-6 Yes No No
WATER HEATING SYSTEMS
---------------------
Number Tank External
Heater in Energy Size Insulation
Tank Type Type Distribution Type System Factor (gal) R-value
------------------------------------------- -------------- ----------------
1 Storage Gas Standard 1 0.62 50 R- n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates HERS verified Insulation Installation.
This building incorporates a HERS verified Refrigerant Charge test
or a HERS verified Thermostatic Expansion Valve (TXV). If a
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified EER.
This building incorporates HERS verified Duct Leakage.
This is a multiple orientation building. This printout is for the front
facing North.
This building incorporates a Radiant Barrier.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM CF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-4R installation certificate. ***
This building incorporates HERS verified Insulation Installation.
This building incorporates a HERS verified Refrigerant Charge test
or a HERS verified Thermostatic Expansion Valve (TXV). If a
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified EER.
This building incorporates HERS verified Duct Leakage. Target leakage is
calculated and documented on the CF-4R. If the measured CFM is above the
target, then corrective action must be taken to reduce the duct leakage and
then must be retested. Alternatively, the compliance calculations could be
redone without duct testing. If ducts are not installed, then HERS
verification is not necessary.
REMARKS
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 7
Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 ,10:41:06
I MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM CF-lR I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title-24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility.
DESIGNER or OWNER DOCUMENTATION AUTHOR
Name.... Kyle Tibbitts
Company. Shea Homes/Trilogy
Address. 60946 Desert Rose
La Quinta, CA 92253
Phone... (: , ZZ1? Q26
License. ��C.C, 5
Signed..
d
(date)
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed..
(date)
Name.... Chinh Nguyen
Company. Westpac Air Conditioning, Inc.
Address. 1610 N. Maple St.
Corona, CA 92880
Phone... (951) 739-9501
Signed.. ),/�
(d te) U
MANDATORY MEASURES CHECKLIST: RESIDENTIAL
-------------------------------------------------------------------------------
MF-lR
Page 1
-------------------------------------------------------------------------------
Project Title..........
Plan 6505/Option Bay 2
Date..02/27/08 10:41:06
Project Address........
******* ---------------------
La Quinta, CA
*v7.10* I
I
Documentation Author...
Chinh Nguyen
******* I Building Permit # I
Westpac Air Conditioning,
Inc. I
1
1610 N. Maple St.
I Plan Check/
Date I
Corona, CA 92880
I
1
(951) 739-9501
I Field Check/
Date I
Climate Zone...........
15
---------------------
Compliance Method......
MICROPAS7 v7.10 for 2005
Standards by Enercomp,
Inc.
1 MICROPAS7 v7.10
File-T6505OB2 Wth-CTZ15S05
Program -FORM MF-lR
1
1 User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta
-------------------------------------------------------------------------------
P-3 I
Note: Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supersede the items marked with
an asterisk (*). When this checklist is incorporated into the permit documents,
the features noted shall be considered by all parties as minimum component
performance specifications for the mandatory measures whether they are shown
elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
De- En-
sign- force-
n/a er ment
i*150(a): Minimum R-19 insulation in wood framed ceiling or
equivalent U-factor in metal frame ceiling
150(b): Loose fill insulation manufacturer's labeled R-Value
*150(c): Minimum R-13 wall insulation in wood framed walls or
equivalent U-factor in metal frame walls (does not apply
to exterior mass walls)
*150(d): Minimum R-13 raised floor insulation in framed floors ✓ /�'
or e uivalent U-factor
q
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door covering the entire
opening of the firebox
b. Outside air intake with damper and control, flue
damper and control
2. No continuous burning gas pilot lights allowed
150(f): Air retarding wrap installed to comply with Sec. 151
/
meets requirements specified in ACM Residential Manual
150(g): Vapor barriers mandatory in Climate Zones 14,16 only
150(1): Slab edge insulation - water absorption rate for the
insulation material without facings no greater than 0.30,
water vapor permeance rate no greater than 2.0 perm/inch
118: Insulation specified or installed meets insulation quality
standards. Indicate type and include CF-6R form
116-17: Fenestration Products, Exterior Doors and Infiltration
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage
�.
2. Fenestration products (except field -fabricated) have
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 2
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-76505OB2 Wth-CTZ15S05 Program -FORM MF-lR I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
label with certified U-factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
n/a
110-113: HVAC equipment, water heaters, showerheads and
faucets certified -by the Energy Commission
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA
150(i): Setback thermostat on all applicable heating and/or
cooling systems
150(j): Water system pipe and tank insulation and cooling
systems line insulation
1. Storage gas water heaters rated with an Energy Factor
less than 0.58 must be externally wrapped with insulation
having an installed thermal resistance of R12 or greater
2. Back-up tanks for solar system, unfired storage tanks, or
other indirect hot water tanks have R-12 external
insulation or R-16 internal and indicated on the
exterior of the tank showing the R-value
3. The following piping is insulated according to Table 150-A/B
or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to
water heater tank, non -recirculating systems, and
entire length of recirculating sections of hot water
pipes shall be insulated to Table 150B
2. Cooling system piping (suction, chilled water, or
brine lines), piping insulated between heating source
and indirect hot water tank shall be insulated to
Table 150-B and Equation 150-A
4. Steam hydronic heating systems or hot, water systems >15 ps
meet requirements of Table 123-A
5. Insulation must be protected from damage, including that due
to sunlight, moisture, equipment maintenance and wind
6. Insulation for chilled water piping and refrigerant suction
piping includes a vapor retardant or is enclosed entirely
in conditioned space
7. Solar water -heating systems/collectors are certified by the,
Solar Rating and Certification Corporation
*150(m): Ducts and ,Fans
1. All ducts and plenums installed, sealed and insulated to
meet the requirements of the CMC Sections 601, 602, 603,
604, 605 and Standard 6-5; supply -air and return -air ducts
and plenums are insulated to a minimum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings
shall be sealed with mastic, tape, or other duct -closure
system that meets the applicable requirements of UL 181,
-z
De- En-
sign- force
er ment
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 3
Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM MF-lR
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
UL 181A, or UL 181B or aerosol sealant that meets the
requirements of UL 723. If mastic or tape is used to seal
openings greater than 1/4 inch, the combination of mastic
and either mesh or tape shall be used
2. Building cavities, support platforms for air handlers, and
plenums defined or constructed with materials other than
sealed sheet metal, duct board or flexible duct shall not
be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in
cavities and support platforms shall not be compressed to cause
reductions in the cross -sectional area of the ducts
3. Joints and seams of duct systems and their components
shall not be sealed with cloth backed rubber adhesive
duct tapes unless such tape is used in combination with /
mastic and draw bands
4. Exhaust fan systems have back draft or automatic dampers /
S. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually /
operated dampers
6. Protection of Insulation. Insulation shall be,protected
from damage due to sunlight, moisture, equipment mainten-
ance and wind. Cellular foam insulation shall be protected
as above or painted with a coating that is water retardant
and provides shielding from solar radiation that can cause
degradation of the material
7. Flexible ducts cannot have porous inner cores
114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance
Efficiency Regulations, on -off switch mounted outside of
the heater, weatherproof operating instructions, no
electric resistance heating and no pilot light
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for future solar heating
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch
115: Gas -fired central furnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
pilot light (Exception: Non -electrical cooking appliances
with pilot < 150 Btu/hr)
118(i): Cool Roof material meets specified criteria
RESIDENTIAL LIGHTING MEASURES
De- En-
sign- force
n/a er ment
150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID:
contain only high efficacy lamps as outlined in Table
150-C, and do not contain a medium screw base socket
(E24/E26). Ballast for lamps 13 watts or greater are electronic
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R
Page 4
Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08
10:41:06
I MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM MF-lR
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta
P-3 I
--------------------------------------- -------------------------------
and have an output frequency no less .than 20 kHz
----
150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain
only high efficacy lamps as outlined in Table 150-C,
luminaire has factory installed HID ballast
150(k)2: Permanently installed luminaires in kitchens shall
be high efficacy luminaires. Up to 50 percent of the wattage,
as determined in Sec. 130(c), of permanently installed luminaires
in kitchens may be in luminaires that are not high efficacy
luminaires, provided that these luminaires are controlled
by switches separate from those controlling the high
efficacy luminaires
150(k)3: Permanently installed luminaires in bathrooms,
garages, laundry rooms, utility rooms shall be high
efficacy luminaires OR are controlled by an occupant
sensor(s) certified to comply with Section 119(d) that
does not turn on automatically or have an always on option
150(k)4: Permanently installed luminaires located other than
in kitchens, bathrooms, garages, laundry rooms, and utility
rooms shall be high efficacy luminaires (except closets
less than 70 ft2), OR are controlled by a dimmer switch
OR are controlled by an occupant sensor(s) that complies
with Section 119(d) that does not turn on automatically
or have an always on option
150(k)5: Luminaires that are recessed into insulated ceilings
are approved for zero clearance insulation cover (IC) and
are certified air tight to ASTM E283 and labeled as air
tight (AT) to less than 2.0 CFM at 75 Pascals
150(k)6: Luminaires providing outdoor lighting and permanently
—yl
mounted to a residential building or to other buildings on
the same lot shall be high efficacy luminaires (not in-
cluding lighting around swimming pools/water features or
other Article 680 locations) OR are controlled by occupant
sensors with integral photo control certified to comply
with Section 119(d)
150(k)7: Lighting for parking lots for 8 or more vehicles shall
have lighting that complies with Sec. 130, 132, and 147.
Lighting for parking garages for 8 or more vehicles shall
have lighting that complies with Sec. 130, 131, and 146
150(k)8: Permanently installed lighting in the enclosed, non -
dwelling spaces of low-rise residential buildings with four
or more dwelling units shall be high efficacy luminaires OR
are controlled by an occupant sensor(s) certified to `
comply with Section 119(d) /
SHEA HOMES
PRODUCT-3
TRILOGY AT LA QUINTA
PLAN -6505/OPT. BAY 21CASITA
Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
CF-lR
Page 1
Project Title..........
Pl 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58
Project Address........
******* ---------------------
La Quinta, CA *v7.10* I
I
Documentation Author...
Chinh Nguyen ******* I
Building Permit # I
Westpac Air Conditioning, Inc. I
I
1610 N. Maple St. I
Plan Check /
Date I
Corona, CA 92880 I
I
(951) 739-9501 I
Field Check/
Date I
Climate Zone...........
15 ---------------------
Compliance Method......
-------------------------------------------------------------------------------
MICROPAS7 v7.10 for 2005 Standards
by Enercomp,
Inc.
-------------------------------------------------------------------------------
I MICROPAS7 v7.10
File-T6505CST Wth-CTZ15S05 Program
-FORM CF-lR
I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy
-------------------------------------------------------------------------------
at La Quinta
P-3 I
----------------------------
----------------------------
MICROPAS7 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed Compliance =
_ (kTDV/sf-yr)
_---------------------------------
Design
Design
--------------------
Margin =
-
- Space
Heating..........
2.60
2.62
-0.02 =
- Space
Cooling..........
77.88
63.53
14.35 =
= Water
Heating..........
9.59
8.86
0.73 =
=
North Total
90.07
75.01
15.06 =
- Space
Heating..........
2.60
2.96
-0.36 =
- Space
Cooling..........
77.88
64.42
13.46 =
= Water
Heating..........
9.59
8.86
0.73 =
=
East Total
90.07
76.24
13.83 =
- Space
Heating..........
2.60
3.40
-0.80 =
- Space
Cooling
77.88
61.90
15.98 =
= Water
Heating..........
9.59
8.86
0.73 =
=
South Total
90.07
74.16
15.91 =
- Space
Heating..........
2.60
2.97
-0.37 =
= Space
Cooling..........
77.88
61.78
16.10 =
= Water
_
Heating..........
9.59
8.86
0.73 =
=
West Total
--------
90.07
----------------
73.61
-
16.46 =
_ ***
Building complies
with Computer Performance
-----------------------------------------------------------------
-----------------------------------------------------------------
*** HERS Verification
Required
for Compliance
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2
-------------------------------------------------------------------------------
Project Title.......... P1 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58
MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM CF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
GENERAL INFORMATION
HERS Verification.......... Required
Conditioned Floor Area..... 2679 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Fuel Type ................. NaturalGas
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... FullYear
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U-factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Slab On Grade
2
26790 cf
2679 sf
27 % of floor area
0.34 Btu/hr-sf-F
0.31
10 ft
BUILDING ZONE
INFORMATION
Floor
-------------------------
# of
# of
Cond-
Thermo-
Vent
Vent
Verified
Area
Volume
Dwell
Peop-
it-
stat
Height
Area
Leakage or
Zone Type
--------------
(sf)
-----
(cf)
------
Units
-----
le
-----
ioned
-----
Type
--------
(ft)
-----
(sf)
-------
Housewrap
----------
HOUSE
Residence
2424
24240
0.80
3.2
Yes
Setback
2.0
Standard
No
CASITA
Residence
255
2550
0.20
0.8
Yes
Setback
2.0
Standard
No
OPAQUE SURFACES
U-
Sheath-
Solar
Appendix
Frame
Area
fact-
Cavity
ing
Act
Gains
IV
Location/
Surface
------------
Type
(sf)
or
R-val
R-val
Azm
Tilt
Reference
Comments
HOUSE
-----
----
-----
-----
-----
---
----
---
---------
--------------
1
Wall
Wood
344
0.102
13
0
180
90
Yes
IV.9
A3
SOUTH
3
Wall
Wood
376
0.102
13
0
270
90
Yes
IV.9
A3
WEST
5
Wall
Wood
212
0.102
13
0
0
90
Yes
IV.9
A3
NORTH
7
Wall
Wood
572
0.102
13
0
90
90
Yes
IV.9
A3
EAST
9
Wall
Wood
13
0.102
13
0
135
90
Yes
IV.9
A3
SOUTHEAST
10
Wall
Wood
13
0.102
13
0
225
90
Yes
IV.9
A3
SOUTHWEST
11
Wall
Wood
562
0.102
13
0
0
90
No
IV.9
A3
GARAGE WALL
12
RoofRad
Wood
2398
0.025
38
0
n/a
0
Yes
IV.1
A18
Attic
14
Door
Wood
20
0.387
0
0
0
90
Yes
None
Wood Door
15
Door
Wood
18
0.387
0
0
0
90
No
None
Wood Door
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3
Project Title.......... Pl 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58
MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM CF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
OPAQUE SURFACES
U-
Sheath-
Solar
Appendix
Frame
Area
fact-
Cavity
ing
Act
Gains
IV
Location/
Surface
------------
Type
(sf)
or
R-val
R-val
Azm
Tilt
Reference
Comments
CASITA
-----
----
-----
-----
-----
---
----
---
---------
--------------
2
Wall
Wood
122
0.102
13
0
180
90
Yes
IV.9 A3
SOUTH
4
Wall
Wood
139
0.102
13
0
270
90
Yes
IV.9 A3
WEST
6
Wall
Wood
152
0.102
13
0
0
90
Yes
IV.9 A3
NORTH
8
Wall
Wood
145
0.102
13
0
90
90
Yes
IV.9 A3
EAST
13
RoofRad
Wood
255
0.025
38
0
n/a
0
Yes
IV.1 A18
Attic
PERIMETER LOSSES
Appendix
Length
F2
Insul
Solar
IV
Location/
Surface
------------
(ft)
------
Factor
--------
R-val
Gains
Reference
Comments
HOUSE
-------
-----
---------
----------------------
16 SlabEdge
220
0.900
R-0
No
None
To Outside
18 SlabEdge
58
0.550
R-0
No
None
TO GARAGE
CASITA
17 SlabEdge
63
0.900
R-0
No
None
To Outside
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
------------------ ----- ----- ----- --- ------------------------------------
1
Wind
Back
(S)
2
Door
Back
(S)
3
Wind
Back
(S)
4
Wind
Back
(S)
5
Door
Back
(S)
6
Wind
Back
(S)
7
Door
Back
(S)
8
Wind
Back
(S)
10
Wind
Right
(W)
11
Wind
Right
(W)
12
Wind
Right
(W)
13
Wind
Right
(W)
15
Wind
Front
(N)
16
Wind
Front
(N)
17
Wind
Front
(N)
18
Wind
Front
(N)
20
Wind
Left
(E)
21
Wind
Left
(E)
12.0 0.340 0.330 180 90 Standard SGLASSI/Vinyl/Fixed Wind
48.0 0.340 0.310 180 90 Standard SGLASS2/French Door
12.0 0.340 0.330 180 90 Standard SGLASS3/Vinyl/Fixed Wind
36.0 0.340 0.300 180 90 Standard SGLASS4/Vinyl/Operable W
48.0 0.340 0.310 180 90 Standard SGLASSS/Vinyl/Sliding Gl
36.0 0.340 0.300 180 90 Standard SGLASS6/Vinyl/Operable W
48.0 0.340 0.310 180 90 Standard SGLASS7/Vinyl/Sliding Gl
36.0 0.340 0.300 180 90 Standard SGLASS8/Vinyl/Operable W
48.0 0.340 0.300 270 90 Standard WGLASSI/Vinyl/Operable W
48.0 0.340 0.300 270 90 Standard WGLASS2/Vinyl/Operable W
24.0 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind
24.0 0.340 0.330 270 90 Standard WGLASS4/Vinyl/Fixed Wind
6.0 0.340 0.330 0 90 Standard NGLASSI/Vinyl/Fixed Wind
6.0 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind
18.0 0.340 0.300 0 90 Standard NGLASS3/Vinyl/Operable W
18.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W
48.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W
6.0 0.340 0.300 90 90 Standard SGLASS2/Vinyl/Operable W
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4
Project Title.......... P1 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58
-----------------------------------------------------------------------------=-
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM CF-lR
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
------------------ ----- ----- ----- --- ------------ ------------------------
22 Wind Left (E) 4.0 0.340 0.330 90 90 Standard EGLASS3/Vinyl/Fixed Wind
23 Wind Left (E) 10.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W
24 Wind Left (E) 20.0 0.340 0.330 90 90 Standard EGLASS5/Vinyl/Fixed Wind
25 Wind Left (E) 10.0 0.340 0.300 90 90 Standard EGLASS6/Vinyl/Operable W
26 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS7/Vinyl/Operable W
27 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS8/Vinyl/Operable W
28 Wind Left (E) 36.0 0.340 0.300 90 90 Standard EGLASS9/Vinyl/Operable W
29 Wind Left (SE) 12.0 0.340 0.330 135 90 Standard SEGLASSI/Vinyl/Fixed Win
30 Wind Back (SW) 12.0 0.340 0.330 225 90 Standard SWGLASSI/Vinyl/Fixed Win
CASITA
9 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS9/Vinyl/Sliding G1
14 Wind Right (W) 6.0 0.340 0.300 270 90 Standard WGLASS5/Vinyl/Operable W
19 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS5/Vinyl/Operable W
OVERHANGS
---Window--- ------------ Overhang ------------
Area Left Right
Surface (sf) Width Height Depth Height Extension Extension
----------- ----- ----- ------ ----- ------ --------- ---------
HOUSE
4 Window 36.0 6.00 6.00 10.0 0.25 n/a n/a
5 Door 48.0 6.00 8.00 10.0 0.25 n/a n/a
7 Door 48.0 6.00 8.00 10.0 0.25 n/a n/a
8 Window 36.0 6.00 6.00 10.0 0.25 n/a n/a
10 Window 48.0 6.00 8.00 10.0 0.25 n/a n/a
11 Window 48.0 6.00 8.00 10.0 0.25 n/a n/a
15 Window 6.0 1.00 6.00 6.00 0.25 n/a n/a
16 Window 6.0 1.00 6.00 6.00 0.25 n/a n/a
20 Window 48.0 6.00 8.00 10.0 0.25 n/a n/a
28 Window 36.0 6.00 6.00 4.00 0.25 n/a n/a
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
HOUSE
Standard Slab 2424
CASITA
Standard Slab 255
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5
Project Title.......... Pl 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM CF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
HVAC SYSTEMS
------------
Verified
Number
Verified
Verified
Verified Verified
Maximum
System
of .
Minimum
Refrig
Charge Adequate Fan Watt
Cooling
Type
------------
Systems
Efficiency
EER or TXV
Airflow Draw
Capacity
HOUSE
-------
-----------
----- -------------
--------
--------
--------
Furnace
1
0.800 AFUE
n/a n/a
n/a n/a
n/a
ACSplit
1
14.00 SEER
11.6 Yes
No No
No
CASITA
HPSplit
1
7.70 HSPF
n/a n/a
n/a n/a
n/a
HPSplit
1
14.00 SEER
11.5 Yes
No No
No
HVAC SIZING
Verified
Total
Sensible
Design
Maximum
Heating
Cooling
Cooling
Cooling
System
Load
Load
Capacity
Capacity
Type
-------------
(Btu/hr)
----------
(Btu/hr)
--------------------
(Btu/hr)
(Btu/hr)
----------
HOUSE
Furnace
49616
n/a
n/a
n/a
ACSplit
n/a
38625
47934
n/a
CASITA
HPSplit
8699
n/a
n/a
n/a
HPSplit
-------------
n/a
6411
7956
n/a
Total
----------
58315
--------------------
45036
55890
----------
n/a
Orientation of Maximum.....
Sizing Location............
Winter Outside Design......
Winter Inside Design.......
Summer Outside Design......
Summer Inside Design.......
Summer Range ...............
Front Facing 90 deg (E)
LA QUINTA
26 F
70 F
111 F
75 F
34 F
DUCT SYSTEMS
------------
Verified
Verified
Verified
System
Duct
Duct Duct
Surface
Buried
Type
-------------
Location
-----------
R-value Leakage
Area
Ducts
HOUSE
--------------
--------
---------
Furnace
Attic
R-6 Yes
No
No
ACSplit
Attic
R-6 Yes
No
No
CASITA
HPSplit
Attic
R-6 Yes
No
No
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 6
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Pl 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM CF-1R I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
------------------------------------------------------- -----------------------
DUCT SYSTEMS
------------
Verified Verified Verified
System Duct Duct Duct Surface Buried
Type Location R-value Leakage Area Ducts
-------------------------------------------------------
HPSplit Attic R-6 Yes No No
WATER HEATING SYSTEMS
---------------------
Number Tank External
Heater in Energy Size Insulation
Tank Type Type Distribution Type System Factor (gal) R-value
------------------------------------------- -------------- ----------------
1 Storage Gas Standard 1 0.62 50 R- n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates HERS verified Insulation Installation.
This building incorporates a HERS verified Refrigerant Charge test
or a HERS verified Thermostatic Expansion Valve (TXV). If a
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified EER.
This building incorporates HERS verified Duct Leakage.
This is a multiple orientation building. This printout is for the front
facing North.
This building incorporates a Radiant Barrier.
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-4R installation certificate. ***
This building incorporates HERS verified Insulation Installation.
This building incorporates a HERS verified Refrigerant Charge test
or a HERS verified Thermostatic Expansion Valve (TXV). If a
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... P1 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM CF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3
-------------------------------------------------------------------------------
HERS REQUIRED VERIFICATION
--------------------------
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified EER.
This building incorporates HERS verified Duct Leakage. Target leakage is
calculated and documented on the CF-4R. If the measured CFM is above the
target, then corrective action must be taken to reduce the duct leakage and
then must be retested. Alternatively, the compliance calculations could be
redone without duct testing. If ducts are not installed, then HERS
verification is not necessary.
REMARKS
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 8
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Pl 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM CF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title-24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility.
DESIGNER or OWNER
Name.... Kyle Tibbitts
Company. Shea Homes/Trilogy
Address. 60946 Desert Rose
La Quinta, CA 92253
Phone... (760) 777-6026
License. 6Zz
Signed.. 3^ y-of
(date)
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed..
(date)
DOCUMENTATION AUTHOR
Name.... Chinh Nguyen
Company. Westpac Air Conditioning, Inc.
Address. 1610 N. Maple St.
Corona, CA 92880
Phone... (951) 739-9501
Signed..
(date)
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 1
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Pl 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58
Project Address........ ******* ---------------------
La Quinta, CA *v7.10* I I
Documentation Author... Chinh Nguyen ******* I Building Permit # I
Westpac Air Conditioning, Inc. I 1
1610 N. Maple St. I Plan Check / Date I
Corona, CA 92880 I 1
(951) 739-9501 I Field Check/ Date I
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM MF-lR I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
Note: Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supersede the items marked with
an asterisk (*). When this checklist is incorporated into the permit documents,
the features noted shall be considered by all parties as minimum component
performance specifications for the mandatory measures whether they are shown
elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
De- En-
sign- force-
n/a
er ment
*150(a): Minimum R-19 insulation in wood framed ceiling or
ZZ�
equivalent U-factor in metal frame ceiling
150(b): Loose fill insulation manufacturer's labeled R-Value
*150(c): Minimum R-13 wall insulation in wood framed walls or
equivalent U-factor in metal frame walls (does not apply
to exterior mass walls)
*150(d): Minimum R-13 raised floor insulation in framed floors /
or equivalent U-factor
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door covering the entire
opening of the firebox
b. Outside air intake with damper and control, flue
damper and control
2. No continuous burning gas pilot lights allowed
150(f): Air retarding wrap installed to comply with Sec. 151
meets requirements specified in ACM Residential Manual
150(g): Vapor barriers mandatory in Climate Zones 14,16 only
150(1): Slab edge insulation - water absorption rate for the
insulation material without facings no greater than 0.3%,
water vapor permeance rate no greater than 2.0 perm/inch
118: Insulation specified or installed meets insulation quality
standards. Indicate type and include CF-6R form _z
116-17: Fenestration Products, Exterior Doors and Infiltration/
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage
2. Fenestration products (except field -fabricated) have
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 2
Project Title.......... P1 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM MF-lR
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
label with certified U-factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed /
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Die En-
sign- force
n/a er ment
110-113: HVAC equipment, water heaters, showerheads and
faucets certified by the Energy Commission
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA
150(i): Setback thermostat on all applicable heating and/or
cooling systems
150(j): Water system pipe and tank insulation and cooling
systems line insulation
1. Storage gas water heaters rated with an Energy Factor
less than 0.58 must be externally wrapped with insulation
having an installed thermal resistance of R12 or greater
2. Back-up tanks for solar system, unfired storage tanks, or
other indirect hot water tanks have R-12 external
insulation or R-16 internal and indicated on the `
exterior of the tank showing the R-value
3. The following piping is insulated according to Table 150-A/B
or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to
water heater tank, non -recirculating systems, and
entire length of recirculating sections of hot water
pipes shall be insulated to Table 150B
2. Cooling system piping (suction, chilled water, or
brine lines), piping insulated between heating source
and indirect hot water tank shall be insulated to
Table 150-B and Equation 150-A
4. Steam hydronic heating systems or hot water systems >15 psi,
meet requirements of Table 123-A T/
5. Insulation must be protected from damage, including that due
to sunlight, moisture, equipment maintenance and wind
6. Insulation for chilled water piping and refrigerant suction
piping includes a vapor retardant or is enclosed entirely
in conditioned space
7. Solar water -heating systems/collectors are certified by the
Solar Rating and Certification Corporation _1z
*150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to
meet the requirements of the CMC Sections 601, 602, 603,
604, 605 and Standard 6-5; supply -air and return -air ducts
and plenums are insulated to a minimum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings
shall be sealed with mastic, tape, or other duct -closure
system that meets the applicable requirements of UL 181,
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 3
Project Title.......... Pl 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58
MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM MF-lR
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
---------------------------------------------------- 7--------------------------
UL 181A, or UL 181B or aerosol sealant that meets the
requirements of UL 723. If mastic or tape is used to seal
openings greater than 1/4 inch, the combination of mastic
and either mesh or tape shall be used
2. Building cavities, support platforms for air handlers, and
plenums defined or constructed with materials other than
sealed sheet metal, duct board or flexible duct shall not
be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in
cavities and support platforms shall not be compressed to cause /
reductions in the cross -sectional area of the ducts
3. Joints and seams of duct systems and their components
shall not be sealed with cloth backed rubber adhesive
duct tapes unless such tape is used in combination with /
mastic and draw bands
4. Exhaust fan systems have back draft or automatic dampers
5. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
operated dampers
6. Protection of Insulation. Insulation shall be protected
from damage due to sunlight, moisture, equipment mainten-
ance and wind. Cellular foam insulation shall be protected
as above or painted with a coating that is water retardant
and provides shielding from solar radiation that can cause /
degradation of the material
7. Flexible ducts cannot have porous inner cores
114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance
Efficiency Regulations, on -off switch mounted outside of
the heater, weatherproof operating instructions, no /
electric resistance heating and no pilot light
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for future solar heating /
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch
115: Gas -fired central furnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
pilot light (Exception: Non -electrical cooking appliances
with pilot.< 150 Btu/hr)
118(i): Cool Roof material meets specified criteria
RESIDENTIAL LIGHTING MEASURES
De- En-
sign- force
n/a er ment
150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID:
contain only high efficacy lamps as outlined in Table
150-C, and do not contain a medium screw base socket
(E24/E26). Ballast for lamps 13 watts or greater are electronic
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 4
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... P1 6505/Opt.Bay 2/Casita Date..02/27/08
-------------------------------------------------------------------------------
10:44:58
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM MF-lR
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta
P-3 I
-----------------------------------------------------------------
and have an output frequency no less than 20 kHz
150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain
only high efficacy lamps as outlined in Table 150-C,
luminaire has factory installed HID ballast
150(k)2: Permanently installed luminaires in kitchens shall
be high efficacy luminaires. Up to 50 percent of the wattage,
as determined in Sec. 130(c), of permanently installed luminaires
in kitchens may be in luminaires that are not high efficacy
luminaires, provided that these luminaires are controlled
by switches separate from those controlling the high
/
efficacy luminaires
150(k)3: Permanently installed luminaires in bathrooms,
garages, laundry rooms, utility rooms shall be high
efficacy luminaires OR are controlled by an occupant
sensor(s) certified to comply with Section 119(d) that
does not turn on automatically or have an always on option
150(k)4: Permanently installed luminaires located other than
in kitchens, bathrooms, garages, laundry rooms, and utility
rooms shall be high efficacy luminaires (except closets
less than 70 ft2), OR are controlled by a dimmer switch
OR are controlled by an occupant sensor(s) that complies
with Section 119(d) that does not turn on automatically
or have an always on option
150(k)5: Luminaires that are recessed into insulated ceilings
are approved for zero clearance insulation cover (IC) and
are certified air tight to ASTM E283 and labeled as air
/
tight (AT) to less than 2.0 CFM at 75 Pascals
J
150(k)6: Luminaires providing outdoor lighting and permanently
mounted to a residential building or to other buildings on
the same lot shall be high efficacy luminaires (not in-
cluding lighting around swimming pools/water features or
other Article 680 locations) OR are controlled by occupant
sensors with integral photo control certified to comply
/
with Section 119(d)
/
150(k)7: Lighting for parking lots for 8 or more vehicles shall
have lighting that complies with Seca 130, 132, and 147.
Lighting for parking garages for 8 or more vehicles shall
have lighting that complies with Sec. 130, 131, and 146
150(k)8: Permanently installed lighting in the enclosed, non -
dwelling spaces of low-rise residential buildings with four
or more dwelling units shall be high efficacy luminaires OR
are controlled by an occupant sensor(s) certified to
comply with Section 119(d) _Z
SHEA HOMES
PRODUCT-3
TRILOGY AT LA QUINTA
PLAN -6420
Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 1
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43
Project Address........ ******* ---------------------
La Quinta, CA *v7.10* I I
Documentation Author... Chinh Nguyen ******* I Building Permit # I
Westpac Air Conditioning, Inc. 1 1
1610 N. Maple St. I Plan Check / Date I
Corona, CA 92880 1 1
(951) 739-9501 1 Field Check/ Date I
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM CF-lR I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
-----------------------------------------------------------------
=
MICROPAS7
ENERGY USE
SUMMARY
=
= Energy Use
Standard
Proposed Compliance
=
_ (kTDV/sf-yr)
_---------------------------------
Design
Design
--------------------
Margin =
-
= Space
Heating..........
2.31
2.44
-0.13 =
- Space
Cooling
75.88
57.45
18.43 =
= Water
Heating..........
10.32
9.54
0.78 =
=
North Total
88.51
69.43
19.08 =
- Space
Heating..........
2.31
1.89
0.42 =
- Space
Cooling..........
75.88
59.92
15.96 =
= Water
Heating..........
10.32
9.54
0.78 =
=
East Total
88.51
71.35
17.16 =
- Space
Heating..........
2.31
2.22
0.09 =
- Space
Cooling..........
75.88
60.20
15.68 =
= Water
Heating..........
10.32
9.54
0.78 =
=
South Total
88.51
71.96
16.55 =
- Space
Heating..........
2.31
2.79
-0.48 =
- Space
Cooling
75.88
58.43
17.45 =
= Water
Heating..........
10.32
9.54
0.78 =
=
West Total
88.51
70.76
17.75 =
_ ***
Building complies
with Computer
Performance
_
-----------------------------------------------------------------
*** HERS Verification
Required
for Compliance
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2
Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43
MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM CF-1R
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
GENERAL INFORMATION
HERS Verification.......... Required
Conditioned Floor Area..... 2477 sf
Building Type.............. Single Family Detached
Construction Type ......... New
Fuel Type ................. NaturalGas
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... FullYear
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U-factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Slab On Grade
1
24770 cf
2477 sf
24.2 % of floor area
0.34 Btu/hr-sf-F
0.31
10 ft
BUILDING ZONE INFORMATION
---=---------------------
Floor # of # of Cond- Thermo- Vent Vent Verified
Area Volume Dwell Peop- it- stat Height Area Leakage or
Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap
-------------- ----- ------ ----- ----- ------------- ----- ------- ----------
Residence 2477 24770 1.00 4.0 Yes Setback 2.0 Standard No
OPAQUE SURFACES
U-
Sheath-
Solar
Appendix
Frame
Area
fact-
Cavity
ing
Act
Gains
IV
Location/
Surface
Type
(sf)
or
R-val
R-val
Azm
Tilt
Reference
Comments
------------
1
Wall
-----
Wood
----
396
-----
0.102
-----
13
-----
0
---
180
----
90
---
Yes
---------
IV.9 A3
--------------
SOUTH
2
Wall
Wood
213
0.102
13
0
270
90
Yes
IV.9 A3
WEST
3
Wall
Wood
483
0.102
13
0
0
90
Yes
IV.9 A3
NORTH
4
Wall
Wood
468
0.102
13
0
90
90
Yes
IV.9 A3
EAST
5
Wall
Wood
36
0.102
13
0
315
90
Yes
IV.9 A3
NORTHWEST
6
Wall
Wood
582
0.102
13
0
0
.90
No
IV.9 A3
GARAGE WALL
7
RoofRad
Wood
2477
0.025
38
0
n/a
0
Yes
IV.1 A18
Attic
8
Door
Wood
20
0.387
0
0
315
90
Yes
None
Wood Door
9
Door
Wood
18
0.387
0
0
0
90
No
None
Wood Door
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM CF-lR
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
PERIMETER LOSSES
----------------
Appendix
Length F2 Insul Solar IV Location/
.Surface (ft) Factor R-val Gains Reference Comments
------------ --------------------- -------------- ----------------------
10 S1abEdge 215 0.900 R-0 No None To Outside
11•SlabEdge 60 0.550 R-0 No None TO GARAGE
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
------------------ ----- ----- ----- --- ------------ ------------------------
1 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASSI/Vinyl/Operable W
2 Wind Back (S) 30.0 0.340 0.300 180 90 Standard SGLASS2/Vinyl/Operable W
3 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS3/French Door
4 Door Right (W) 40.0 0.340 0.310 270 90 Standard WGLASSI/French Door
5 Wind Right (W) 2.3 0.340 0.330 270 90 Standard WGLASS2/Vinyl/Fixed Wind
6 Wind Right (W) 2.3 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind
7 Wind Right (W) 2.3 0.340 0.330 270 90 Standard WGLASS4/Vinyl/Fixed Wind
8 Wind Front (N) 24.0 0.340 0.300 0 90 Standard NGLASSI/Vinyl/Operable W
9 Wind Front (N) 24.0 0.340 0.300 0 90 Standard NGLASS2/Vinyl/Operable W
10 Door Front (N) 21.5 0.340 0.310 0 90 Standard NGLASS3/French Door
11 Wind Front (N) 6.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W
12 Wind Front (N) 40.0 0.340 0.300 0 90 Standard NGLASSS/Vinyl/Operable W
13 Wind Front (N) 10.0 0.340 0.330 0 90 Standard NGLASS6/Vinyl/Fixed Wind
14 Door Front (N) 24.0 0.340 0.310 0 90 Standard NGLASS7/French Door
15 Door Front (N) 48.0 0.340 0.310 0 90 Standard NGLASS8/Vinyl/Sliding G1
16 Wind Left (E) 20.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W
17 Wind Left (E) 12.0 0.340 0.300 90 90 Standard SGLASS2/Vinyl/Operable W
18 Door Left (E) 48.0 0.340 0.310 90 90 Standard SGLASS3/French Door
19 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W
20 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS5/Vinyl/Operable W
21 Door Left (E) 48.0 0.340 0.310 90 90 Standard EGLASS6/French Door.
22 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS7/Vinyl/Operable W
23 Wind Left (E) 24.0 0.340 0.300 90 90 Standard EGLASS8/Vinyl/Operable W
24 Wind Left (E) 24.0 0.340 0.300 90 90 Standard EGLASS9/Vinyl/Operable W
25 Wind Left (E) 20.0 0.340 0.300 90 90 Standard EGLASS10/Vinyl/Operable
26 Wind Right (NW) 9.0 0.340 0.330 315 90 Standard NWGLASSI/Vinyl/Fixed Win
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-TRI 6420 Wth-CTZ15S05 Program -FORM CF-lR
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
OVERHANGS
---Window---
------------
Overhang ------------
Area
Left
Right
Surface
-----------
(sf)
-----
Width
-----
Height
------
Depth
-----
Height Extension
---------------
Extension
---------
3
Door
48.0
6.00
8.00
10.0
0.50
n/a
n/a
4
Door
40.0
5.00
8.00
3.00
0.50
n/a
n/a
12
Window
40.0
5.00
8.00
7.00
0.50
n/a
n/a
14
Door
24.0
3.00
8.00
8.00
0.50
n/a
n/a
15
Door
48.0
6.00
8.00
8.00
0.50
n/a
n/a
16
Window
20.0
5.00
4.00
8.00
1.00
n/a
n/a
20
Window
12.0
2.00
6.00
8.00
1.00
n/a
n/a
21
Door
48.0
6.00
8.00
8.00
1.00
n/a
n/a
22
Window
12.0
2.00
6.00
8.00
1.00
n/a
n/a
26
Window
9.0
1.50
6.00
6.00
1.00
n/a
n/a
SLAB SURFACES
-------------
Area
Slab Type
(sf)
----------------
Standard
------
Slab 2477
HVAC SYSTEMS
------------
Verified
Number
Verified
Verified Verified Verified
Maximum
System
of
Minimum
Refrig Charge Adequate Fan Watt
Cooling
Type
Systems
Efficiency
EER or TXV Airflow Draw
Capacity
------------
Furnace
-------
1
-----------
0.800 AFUE
----- ------------- -------- --------
n/a n/a n/a n/a
--------
n/a
ACSplit
1
14.00 SEER
11.5 Yes No No
No
HVAC SIZING
Verified
Total
Sensible Design Maximum
Heating
Cooling Cooling Cooling
System
Load
Load Capacity Capacity
Type
-------------
(Btu/hr)
----------
(Btu/hr) (Btu/hr) (Btu/hr)
------------------------------
Furnace
49397
n/a n/a n/a
ACSplit
n/a
39589 49130 n/a
Orientation of Maximum..... Front Facing 90 deg (E)
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM CF-lR I
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
Sizing Location............ LA QUINTA
Winter Outside Design...... 26 F
Winter Inside Design....... 70 F
Summer Outside Design...... 111 F
Summer Inside Design....... 75 F
Summer Range ............... 34 F
DUCT SYSTEMS
------------
Verified Verified Verified
System Duct Duct Duct Surface Buried
Type Location R-value Leakage Area Ducts
-------------------------------------------------------
Furnace Attic R-6 Yes No No
ACSplit Attic R-6 Yes No No
WATER HEATING SYSTEMS
---------------------
Number Tank External
Heater in Energy Size Insulation
Tank Type Type Distribution Type System Factor (gal) R-value
------------------------------------------- -------------- ----------------
1 Storage Gas Standard 1 0.62 50 R- n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates HERS verified Insulation Installation.
This building incorporates a HERS verified Refrigerant Charge test
or a HERS verified Thermostatic Expansion Valve (TXV). If a
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified EER.
This building incorporates HERS verified Duct Leakage.
This is a multiple orientation building. This printout is for the front
facing North.
This building incorporates a Radiant Barrier.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 6
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-TRI 6420 Wth-CTZ15S05 Program -FORM CF-lR
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-4R installation certificate. ***
This building incorporates HERS verified Insulation Installation.
This building incorporates a HERS verified Refrigerant Charge test
or a HERS verified Thermostatic Expansion Valve (TXV). If a
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified EER.
This building incorporates HERS verified Duct Leakage. Target leakage is
calculated and documented on the CF-4R. If the measured CFM is above the
target, then corrective action must be taken to reduce the duct leakage and
then must be retested. Alternatively, the compliance calculations could be
redone without duct testing. If ducts are not installed, then HERS
verification is not necessary.
REMARKS
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM CF-lR I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title-24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility.
DESIGNER or OWNER
Name.... Kyle Tibbitts
Company. Shea Homes/Trilogy
Address. 60946 Desert Rose
La Quinta, CA 92253
Phone... (760) 777-6026
License. -76zx-
= ".Vomlrdil
._
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed..
(date)
DOCUMENTATION AUTHOR
Name.... Chinh Nguyen
Company. Westpac Air Conditioning, Inc.
Address. 1610 N. Maple St.
Corona, CA 92880
Phone... (951) 739-9501
Signed..
(date)
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 1
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43
Project Address........ ******* ---------------------
La Quinta, CA *v7.10* I I
Documentation Author.... Chinh Nguyen ******* I Building Permit # I
Westpac Air Conditioning, Inc. I I
1610 N. Maple St. I Plan Check / Date I
Corona, CA 92880 1 I
(951) 739-9501 1 Field Check/ Date I
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM MF-1R I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3
-------------------------------------------------------------------------------
Note: Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supersede the items marked with
an asterisk (*). When this checklist is incorporated into the permit documents,
the features noted shall be considered by all parties as minimum component
performance specifications for the mandatory measures whether they are shown
elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES De- En-
sign- force-
n/a er ment
*150(a): Minimum R-19 insulation in wood framed ceiling or
equivalent U-factor in metal frame ceiling A-a8
150(b): Loose fill insulation manufacturer's labeled R-Value
*150(c): Minimum R-13 wall insulation in wood framed walls or
equivalent U-factor in metal frame walls (does not apply
to exterior mass walls)—��
*150(d): Minimum R-13 raised floor insulation in framed floors
or equivalent U-factor
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door covering the entire
opening of the firebox
b. Outside air intake with damper and control, flue
damper and control
2. No continuous burning gas pilot lights allowed
/
150(f): Air retarding wrap installed to comply with Sec. 151
meets requirements specified in ACM Residential Manual
150(g): Vapor barriers mandatory in Climate Zones 14,16 only
150(1): Slab edge insulation - water absorption rate for the
insulation material without facings no greater than 0.30,
water vapor permeance rate no greater than 2.0 perm/inch
118: Insulation specified or installed meets insulation quality
standards. Indicate type and include CF-6R form
116-17: Fenestration Products, Exterior Doors and Infiltration'
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage
2. Fenestration products (except field -fabricated) have
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 2
Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM MF-lR I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
label with certified U-factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
De- En-
sign- force
n/a
er ment
110-113: HVAC equipment, water heaters, showerheads and
faucets certified by the Energy Commission
/
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA
�\
150(i): Setback thermostat on all applicable heating and/or
cooling systems
150(j): Water system pipe and tank insulation and cooling
systems line insulation
1. Storage gas water heaters rated with an Energy Factor
less than 0.58 must be externally wrapped with insulation
/
having an installed thermal resistance of R12 or greater
2. Back-up tanks for solar system, unfired storage tanks, or
other indirect hot water tanks have R-12 external
insulation or R-16 internal and indicated on the
exterior of the tank showing the R-value
3. The following piping is insulated according to Table 1502A/B
or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to
water heater tank, non -recirculating systems, and
entire length of recirculating sections of hot water
pipes shall be insulated to Table 150B
_
2. Cooling system piping (suction, chilled water, or
brine lines), piping insulated between heating source
and indirect hot water tank shall be insulated to
Table 150-B and Equation 150-A
4. Steam hydronic heating systems or hot water systems >15 psi,
meet requirements of Table 123-A
5. Insulation must be protected from damage, including that due
to sunlight, moisture, equipment maintenance and wind
6. Insulation for chilled water piping and refrigerant suction
�G
piping includes a vapor retardant or is enclosed entirely
/
in conditioned space
7. Solar water -heating systems/collectors are certified by the ,
Solar Rating and Certification Corporation
*150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to
meet the requirements of the CMC Sections 601, 602, 603,
604, 605 and Standard 6-5; supply -air and return -air ducts
and plenums are insulated to a minimum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings
shall be sealed with mastic, tape, or other duct -closure
system that meets the applicable requirements of UL 181,
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 3
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM MF-lR
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
UL 181A, or UL 181B or aerosol sealant that meets the
requirements of UL 723. If mastic or tape is used to seal
openings greater than 1/4 inch, the combination of mastic
and either mesh or tape shall be used
2.
Building.cavities, support platforms for air handlers, and
plenums defined or constructed with materials other than
sealed sheet metal, duct board or flexible duct shall not
be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in
cavities and support platforms shall not be compressed to cause
/
reductions in the cross -sectional area of the ducts
3.
Joints and seams of duct systems and their components
shall not be sealed with cloth backed rubber adhesive
duct tapes unless such tape is used in combination with
mastic and draw bands
4.
Exhaust fan systems have back draft or automatic dampers
5.
Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
operated dampers
6.
Protection of Insulation. Insulation shall be protected
from damage due to sunlight, moisture, equipment mainten-
ance and wind. Cellular foam insulation shall be protected
as above or painted with a coating that is water retardant
and provides shielding from solar radiation that can cause
degradation of the material
z
7.
Flexible ducts cannot have porous inner cores
114:
Pool and Spa Heating Systems and Equipment
1.
A thermal efficiency that complies with the Appliance
Efficiency Regulations, on -off switch mounted outside of
the heater, weatherproof operating instructions, no
electric resistance heating and no pilot light
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for future solar heating
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch -�
115: Gas -fired central furnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
pilot light (Exception: Non -electrical cooking appliances
with pilot < 150 Btu/hr)
118(i): Cool Roof material meets specified criteria
RESIDENTIAL LIGHTING MEASURES De- En-
sign- force
n/a er ment
150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID:
contain only high efficacy lamps as outlined in Table
150-C, and do not contain a medium screw base socket
(E24/E26). Ballast for lamps 13 watts or greater are electronic
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 4
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420 Standard Date..02/27/08
-------------------------------------------------------------------------------
10:46:43
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM MF-lR
I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta
P-3 I
---------------------------------------------------------------------,----1------
and have an output frequency no less than 20 kHz
150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain
only high efficacy lamps as outlined in Table 150-C,
luminaire has factory installed HID ballast
150(k)2: Permanently installed luminaires in kitchens shall
be high efficacy luminaires. Up to 50 percent of the wattage,
as determined in Sec. 130-(c), of permanently installed luminaires
in kitchens may be in luminaires that are not high efficacy
luminaires, provided that these luminaires are controlled
by switches separate from those controlling the high
efficacy luminaires
150(k)3: Permanently installed luminaires in bathrooms,
garages, laundry rooms, utility rooms shall be high
efficacy luminaires OR are controlled by an occupant
sensor(s) certified to comply with Section 119(d) that
does not turn on automatically or have an always on option
150(k)4: Permanently installed luminaires located other than
in kitchens, bathrooms, garages, laundry rooms, and utility
rooms shall be high efficacy luminaires (except closets
less than 70 ft2), OR are controlled by a dimmer switch
OR are controlled by an occupant sensor(s) that complies
with Section 119(d) that does not turn on automatically
or have an always on option
150(k)5: Luminaires that are recessed into insulated ceilings
are approved for zero clearance insulation cover (IC) and
are certified air tight to ASTM E283 and labeled as air
tight (AT) to less than 2.0 CFM at 75 Pascals
150(k)6: Luminaires providing outdoor lighting and permanently
mounted to a residential building or to other buildings on
the same lot shall be high efficacy luminaires (not in-
cluding lighting around swimming pools/water features or
other Article 680 locations) OR are controlled by occupant
sensors with integral photo control certified to comply
with Section 119(d)
150(k)7: Lighting for parking lots for 8 or more vehicles shall
have lighting that complies with Sec. 130, 132, and 147.
Lighting for parking garages for 8 or more vehicles shall
have lighting that complies with Sec. 130, 131, and 146
150(k)8: Permanently installed lighting in the enclosed, non -
dwelling spaces of low-rise residential buildings with four
or more dwelling units shall be high efficacy luminaires OR
are controlled by an occupant sensor(s) certified to /
comply with Section 119(d)
SHEA HOMES
PRODUCT-3
TRILOGY AT LA QUINTA
PLAN-6420/OPT. BAY 2
Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1
---------------------------------------=---------------------------------------
Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57
Project Address........ ******* ---------------------
La Quinta, CA *.v7.10* I I
Documentation Author... Chinh Nguyen ******* I Building Permit # I
Westpac Air Conditioning, Inc. I
1610 N. Maple St. I Plan Check / Date I
Corona, CA 92880 I I
(951) 739-9501 I Field Check/ Date I
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM CF-1R I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
----------------------------
----------------------------
MICROPAS7 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed Compliance =
_ (kTDV/sf-yr)
----------------------------------
Design
Design
--------------------
Margin =
_
- Space
Heating..........
2.28
2.41
-0.13 =
= Space
Cooling..........
75.55
56.98
18.57 =
= Water
Heating..........
10.26
9.49
0.77 =
=
North Total
88.09
68.88
19.21 =
= Space
Heating..... ...
2.28
1.87
0.41 =
= Space
Cooling..........
75.55
59.42
16.13 =
= Water
_
Heating..........
10.26
9.49
0.77 =
-
=
East Total
--------
88.09
----------------
70.78
17.31 =
- Space
Heating..........
2.28
2.19
0.09 =
- Space
Cooling..........
75.55
59.69
15.86 =
= Water
_
Heating..........
10.26
9.49
0.77 =
-
=
South Total
--------
88.09
----------------
71.37
16.72 =
- Space
Heating..........
2.28
2.74
-0.46 =
- Space
Cooling..........
75.55
57.95
17.60 =
= Water
_
Heating..........
10.26
9.49
0.77 =
-
=
West Total
--------
88.09
----------------
70.18
17.91 =
_ ***
Building complies
with Computer Performance
_
*** HERS Verification
Required
for Compliance
*** _
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM CF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
GENERAL INFORMATION
HERS Verification.......... Required
Conditioned Floor Area..... 2503 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Fuel Type ................. NaturalGas
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... FullYear
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U-factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Slab On Grade
1
25030 cf
2503 sf
23.9 % of floor area
0.34 Btu/hr-sf-F
0.31
10 ft
BUILDING ZONE INFORMATION
Floor # of # of Cond- Thermo- Vent Vent Verified
Area Volume Dwell Peop- it- stat Height Area Leakage or
Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap
-------------- ----- ------ ----- ----- ------------- ----- ------- ----------
Residence 2503 25030 1.00 4.0 Yes Setback 2.0 Standard No
OPAQUE SURFACES
U-
Sheath-
Solar Appendix
Frame
Area
fact-
Cavity
ing
Act
Gains
IV
Location/
Surface
Type
(sf)
or
R-val
R-val
Azm
Tilt
Reference
Comments
------------
1
Wall
-----
Wood
----
396
-----
0.102
-----
13
-----
0
---
180
----
90
---
Yes
---------
IV.9 A3
--------------
SOUTH
2
Wall
Wood
213
0.102
13
0
270
90
Yes
IV.9 A3
WEST
3
Wall
Wood
483
0.102
13
0
0
90
Yes
IV.9 A3
NORTH
4
Wall
Wood
468
0.102
13
0
90
90
Yes
IV.9 A3
EAST
5
Wall
Wood
36
0.102
13
0
315
90
Yes
IV.9 A3
NORTHWEST
6
Wall
Wood
582
0.102
13
0
0
90
No
IV.9 A3
GARAGE WALL
7
RoofRad
Wood
2477
0.025
38
0
n/a
0
Yes
IV.1 A18
Attic
8
Door
Wood
20
0.387
0
0
315
90
Yes
None
Wood Door
9
Door
Wood
18
0.387
0
0
0
90
No
None
Wood Door
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3
Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM CF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
PERIMETER LOSSES
Appendix
Length F2 Insul Solar IV Location/
Surface (ft) Factor R-val Gains Reference Comments
------------ --------------------- -------------- ----------------------
10 S1abEdge 215 0.900 R-0 No None To Outside
11 SlabEdge 60 0.550 R-0 No None TO GARAGE
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
------------------ --.--- ----- ----- --- ------------ ------------------------
1 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASSI/Vinyl/Operable W
2 Wind Back (S) 30.0 0.340 0.300 180 90 Standard SGLASS2/Vinyl/Operable W
3 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS3/French Door
4 Door Right (W) 40.0 0.340 0.310 270 90 Standard WGLASSI/French Door
5 Wind Right (W) 2.3 0.340 0.330 270 90 Standard WGLASS2/Vinyl/Fixed Wind
6 Wind Right (W) 2.3 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind
7 Wind Right (W) 2.3 0.340 0.330 270 90 Standard WGLASS4/Vinyl/Fixed Wind
8 Wind Front (N) 24.0 0.340 0.300 0 90 Standard NGLASSI/Vinyl/Operable W
9 Wind Front (N) 24.0 0.340 0.300 0 90 Standard NGLASS2/Vinyl/Operable W
10 Door Front (N) 21.5 0.340 0.310 0 90 Standard NGLASS3/French Door
11 Wind Front (N) 6.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W
12 Wind Front (N) 40.0 0.340 0.300 0 90 Standard NGLASS5/Vinyl/Operable W
13 Wind Front (N) 10.0 0.340 0.330 0 90 Standard NGLASS6/Vinyl/Fixed Wind
14 Door Front (N) 24.0 0.340 0.310 0 90 Standard NGLASS7/French Door
15 Door Front (N) 48.0 0.340 0.310 0 90 Standard NGLASS8/Vinyl/Sliding G1
16 Wind Left (E) 20.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W
17 Wind Left (E) 12.0 0.340 0.300 90 90 Standard SGLASS2/Vinyl/Operable W
18 Door Left (E) 48.0 0.340 0.310 90 90 Standard SGLASS3/French Door
19 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W
20 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASSS/Vinyl/Operable W
21 Door Left (E) 48.0 0.340 0.310 90 90 Standard EGLASS6/French Door
22 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS7/Vinyl/Operable W
23 Wind Left (E) 24.0 0.340 0.300 90 90 Standard EGLASS8/Vinyl/Operable W
24 Wind Left (E) 24.0 0.340 0.300 90 90 Standard EGLASS9/Vinyl/Operable W
25 Wind Left (E) 20.0 0.340 0.300 90 90 Standard EGLASS10/Vinyl/Operable
26 Wind Right (NW) 9.0 0.340 0.330 315 90 Standard NWGLASSI/Vinyl/Fixed Win
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4
Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57
MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM CF-1R
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3
-------------------------------------------------------------------------------
OVERHANGS
Window--- ------------ Overhang ------------
Area
Left
Right
Surface
(sf)
Width
Height
Depth
Height Extension
Extension
-----------
3
Door
-----
48.0
-----
6.00
------
8.00
-----
10.0
---------------
0.50
n/a
---------
n/a
4
Door
40.0
5.00
8.00
3.00
0.50
n/a
n/a
12
Window
40.0
5.00
8.00
7.00
0.50
n/a
n/a
14
Door
24.0
3.00
8.00
8.00
0.50
n/a
n/a
15
Door
48.0
6.00
8.00
8.00
0.50
n/a
n/a
16
Window
20.0
5.00
4.00
8.00
1.00
n/a
n/a
20
Window
12.0
2.00
6.00
8.00
1.00
n/a
n/a
21
Door
48.0
6.00
8.00
8.00
1.00
n/a
n/a
22
Window
12.0
2.00
6.00
8.00
1.00
n/a
n/a
26
Window
9.0
1.50
6.00
6.00
1.00
n/a
n/a
SLAB SURFACES
-------------
Area
Slab Type
----------------
(sf)
------
Standard
Slab 2503
HVAC SYSTEMS
------------
Verified
Number
Verified Verified Verified Verified
Maximum
System
of
Minimum
Refrig
Charge Adequate Fan Watt
Cooling
Type
------------
Systems
-------
Efficiency
EER or TXV
Airflow Draw
Capacity
Furnace
1
-----------
0.800 AFUE
----- -------------
n/a n/a
-------- --------
n/a n/a
--------
n/a
ACSplit
1
14.00 SEER
11.5 Yes
No No
No
HVAC SIZING
e
Verified
Total
Sensible
Design Maximum
Heating
Cooling
Cooling Cooling
System
Load
Load
Capacity Capacity
Type
-------------
(Btu/hr)
----------
(Btu/hr)
--------------------
(Btu/hr) (Btu/hr)
Furnace
49510
n/a
----------
n/a n/a
ACSplit
n/a
39656
49213 n/a
Orientation of Maximum..... Front Facing 90 deg (E)
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM CF-1R I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
Sizing Location............ LA QUINTA
Winter Outside Design...... 26 F
Winter Inside Design....... 70 F
Summer Outside Design...... 111 F
Summer Inside Design....... 75 F
Summer Range ............... 34 F
DUCT SYSTEMS
------------
Verified Verified Verified
System Duct Duct Duct Surface Buried
Type Location R-value Leakage Area Ducts
-------------------------------------------------------
Furnace Attic R-6 Yes No No
ACSplit Attic R-6 Yes No No
WATER HEATING SYSTEMS
---------------------
Number Tank External
Heater in Energy Size Insulation
Tank Type Type Distribution Type System Factor (gal) R-value
------------------------------------------- -------------- ----------------
1 Storage Gas Standard 1 0.62 50 R- n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates HERS verified Insulation Installation.
This building incorporates a HERS verified Refrigerant Charge test
or a HERS verified Thermostatic Expansion Valve (TXV). If a
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified EER.
This building incorporates HERS verified Duct Leakage.
This is a multiple orientation building. This printout is for the front
facing North.
This building incorporates a Radiant Barrier.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6
Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM CF-lR
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-4R installation certificate. ***
This building incorporates HERS verified Insulation Installation.
This building incorporates a HERS verified Refrigerant Charge test
or a HERS verified Thermostatic Expansion Valve (TXV). If a
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified EER.
This building incorporates HERS verified Duct Leakage. Target leakage is
calculated and documented on the CF-4R. If the measured CFM is above the
target, then corrective action must be taken to reduce the duct leakage and
then must be retested. Alternatively, the compliance calculations could be
redone without duct testing. If ducts are not installed, then HERS
verification is not necessary.
REMARKS
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM CF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title-24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility.
DESIGNER or OWNER
Name.... Kyle Tibbitts
Company. Shea Homes/Trilogy
Address. 60946 Desert Rose
La Quinta, CA 92253
Phone... (760) 777-6026
License. qo 77 5?5
Signed.. 16'e // - 3 -1-0
(date)
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed.
(date)
Name...
Company
Address
Phone...
Signed..
DOCUMENTATION AUTHOR
Chinh Nguyen
Westpac Air Conditioning, Inc.
1610 N. Maple St.
Corona, CA 92880
(951) 739-9501
- v%
(date) 0
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 1
-------------------------------------------------------------------------------
Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57
Project Address........ ******* ---------------------
Documentation Author..
Climate Zone..........
La Quinta, CA
Chinh Nguyen
Westpac Air Conditioning,
1610 N. Maple St.
Corona, CA 92880
(951) 739-9501
15
*v7.10* 1 I
******* I Building Permit # I
Inc. I I
I Plan Check / Date I
I I
I Field Check/ Date I
---------------------
Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM MF-lR j
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
Note: Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supersede the items marked with
an asterisk (*). When this checklist is incorporated into the permit documents,
the features noted shall be considered by all parties as minimum component
performance specifications for the mandatory measures whether they are shown
elsewhere in the documents,or on this checklist only.
BUILDING ENVELOPE MEASURES De- En-
sign- force-
n/a er ment
*150(a): Minimum R-19 insulation in wood framed ceiling or
equivalent U-factor in metal frame ceiling
150(b): Loose fill insulation manufacturer's labeled R-Value
*150(c): Minimum R-13 wall insulation in wood framed walls or
equivalent U-factor in metal frame walls (does not apply
/
to exterior mass walls)
*150(d): Minimum R-13 raised floor insulation in framed floors
or equivalent U-factor
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door covering the entire
opening of the firebox
b. Outside air intake with damper and control, flue
damper and control
2. No continuous burning gas pilot lights allowed
150(f): Air retarding wrap installed to comply with Sec. 151
meets requirements specified in ACM Residential Manual
/
150(g): Vapor barriers mandatory in Climate Zones 14,16 only
150(1): Slab edge insulation - water absorption rate for the
insulation material without facings no greater than 0.30,
water vapor permeance rate no greater than 2.0 perm/inch
118: Insulation specified or installed meets insulation quality
standards. Indicate type and include CF-6R form
116-17: Fenestration Products, Exterior Doors and Infiltration/
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage
2. Fenestration products (except field -fabricated) have
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 2
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57
MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM MF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
label with certified U-factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
De- En-
sign- force
n/a
er ment
110-113: HVAC equipment, water heaters, showerheads and
faucets certified by the Energy Commission
150(h): Heating and/or cooling loads calculated in accordance
/
with ASHRAE, SMACNA or ACCA
150(i): Setback thermostat on all applicable heating and/or
cooling systems
150(j): Water system pipe and tank insulation and cooling
systems line insulation
1. Storage gas water heaters rated with an Energy Factor
less than 0.58 must be externally wrapped with insulation
having an installed thermal resistance of R12 or greater
/
2. Back-up tanks for solar system, unfired storage tanks, or
other indirect hot water tanks have R-12 external
insulation or R-16 internal and indicated on the
exterior of the tank showing the R-value
3. The following piping is insulated according to Table 150-A/B
or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to
water heater tank, non -recirculating systems, and
entire length of recirculating sections of hot water
pipes shall be insulated to Table 150B
2. Cooling system piping (suction, chilled water, or
7—
brine lines), piping insulated between heating source
and indirect hot water tank shall be insulated to
/
Table 150-B and Equation 150-A
4. Steam hydronic heating systems or hot water systems >15 psi,
meet requirements of Table 123-A
5. Insulation must be protected from damage, including that due
to sunlight, moisture, equipment maintenance and wind
6. Insulation for chilled water piping and refrigerant suction
piping includes a vapor retardant or is enclosed entirely
in conditioned space
7. Solar water -heating systems/collectors are certified by the
Solar Rating and Certification Corporation
*150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to
meet the requirements of the CMC Sections 601, 602, 603,
604, 605 and Standard 6-5; supply -air and return -air ducts
and plenums are insulated to a minimum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings
shall be sealed with mastic, tape, or other duct -closure
system that meets the applicable requirements of UL 181,
7
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 3
Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57
MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM MF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3
-------------------------------------------------------------------------------
UL 181A, or UL 181B or aerosol sealant that meets the
requirements of UL 723. If mastic or tape is used to seal
openings greater than 1/4 inch, the combination of mastic
and either mesh or tape shall be used
/
2.
Building cavities, support platforms for air handlers, and
T
plenums defined or constructed with materials other than
sealed sheet metal, duct board or flexible duct shall not
be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in
cavities and support platforms shall not be compressed to cause
reductions in the cross -sectional area of the ducts
3.
Joints and seams of duct systems and their components
shall not be sealed with cloth backed rubber adhesive
duct tapes unless such tape is used in combination with
mastic and draw bands
4.
Exhaust fan systems have back draft or automatic dampers
5.
Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
operated dampers
6.
Protection of Insulation. Insulation shall be protected
from damage due to sunlight, moisture, equipment mainten-
ance and wind. Cellular foam insulation shall be protected
as above or painted with a coating that is water retardant
and provides shielding from solar radiation that can cause
degradation of the material
7.
Flexible ducts cannot have porous inner cores
114:
Pool and Spa Heating Systems and Equipment
1.
A thermal efficiency that complies with the Appliance
Efficiency Regulations, on -off switch mounted outside of
the heater, weatherproof operating instructions, no
electric resistance heating and no pilot light
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for future solar heating /
b. Cover for outdoor pools or outdoor spas. J
3. Pool system has directional inlets and a circulation
pump time switch
115: Gas -fired central furnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
pilot light (Exception: Non -electrical cooking appliances
with pilot < 150 Btu/hr)
118(i): Cool Roof material meets specified criteria
RESIDENTIAL LIGHTING MEASURES
De- En-
sign- force
n/a er ment
150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID:
contain only high efficacy lamps as outlined in Table
150-C, and do not contain a medium screw base socket
(E24/E26). Ballast for lamps 13 watts or greater are electronic
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Page 4
Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
10:48:57
MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM MF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta
P-3
------------------------------------------------------------------
and have an output frequency no less than 20 kHz
150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain
only high efficacy lamps as outlined in Table 150-C,
luminaire has factory installed HID ballast
150(k)2: Permanently installed luminaires in kitchens shall
be high efficacy luminaires. Up to 50 percent of the wattage,
as determined in Sec. 130(c), of permanently installed luminaires
in kitchens may be in luminaires that are not high efficacy
luminaires, provided that these luminaires are controlled
by switches separate from those controlling the high
efficacy luminaires
150(k)3: Permanently installed luminaires in bathrooms,
garages, laundry rooms, utility rooms shall be high
efficacy luminaires OR are controlled by an occupant
sensor(s) certified to comply with Section 119(d) that
does not turn on automatically or have an always on option
150(k)4: Permanently installed luminaires located other than
in kitchens, bathrooms, garages, laundry rooms, and utility
rooms shall be high efficacy luminaires (except closets
less than 70 ft2), OR are controlled by a dimmer switch
OR are controlled by an occupant sensor(s) that complies
with Section 119(d) that does not turn on automatically
/
or have an always on option
150(k)5: Luminaires that are recessed into insulated ceilings
are approved for zero clearance insulation cover (IC) and
are certified air tight to ASTM E283 and labeled as air
tight (AT) to less than 2.0 CFM at 75 Pascals
150(k)6: Luminaires providing outdoor lighting and permanently
mounted to a residential building or to other buildings on
the same lot shall be high efficacy luminaires (not in-
cluding lighting around swimming pools/water features or
other Article 680 locations) OR are controlled by occupant
sensors with integral photo control certified to comply
with Section 119(d)
150(k)7: Lighting for parking lots for 8 or more vehicles shall
have lighting that complies with Sec. 130, 132, and 147.
Lighting for parking garages for 8 or more vehicles shall /
have lighting that complies with Sec. 130, 131, and 146
t/
150(k)8: Permanently installed lighting in the enclosed, non -
dwelling spaces of low-rise residential buildings with four
or more dwelling units shall be high efficacy luminaires OR j
are controlled by an occupant sensor(s) certified to
comply with Section 119(d)
SHEA HOMES
PRODUCT-3
TRILOGY AT LA QUINTA
PLAN-6420/OPT. BAY 21CASITA
Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 1
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46
Project Address........ ******* ---------------------
La Quinta, CA *v7.10* I I
Documentation Author... Chinh Nguyen ******* I Building Permit # I
Westpac Air Conditioning, Inc. 1
1610 N. Maple St. Plan Check / Date I
Corona, CA 92880 1
(951) 739-9501 1 Field Check/ Date I
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-1R
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
----------------------------
----------------------------
MICROPAS7 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed Compliance =
_ (kTDV/sf-yr)
----------------------------------
Design
Design
--------------------
Margin =
-
= Space
Heating..........
2.57
2.86
-0.29 =
- Space
Cooling..........
77.36
60.08
17.28 =
= Water
_
Heating..........
9.31
--------
8.61
0.70 =
-
=
North Total
89.24
----------------
71.55
17.69 =
- Space
Heating..........
2.57
2.38
0.19 =
- Space
Cooling..........
77.36
62.95
14.41 =
= Water
_
Heating..........
9.31
8.61
0.70 =
-
=
East Total
--------
89.24
----------------
73.94
15.30 =
- Space
Heating..........
2.57
2.69
-0.12 =
= Space
Cooling..........
77.36
62.15
15.21 =
= Water
_
Heating..........
9.31
8.61
0.70 =
-
=
South Total
--------
89.24
----------------
73.45
15.79 =
= Space
Heating..........
2.57
3.16
-0.59 =
- Space
Cooling..........
77.36
61.37
15.99 =
= Water
_
Heating..........
9.31
8.61
0.70 =
-
=
West Total
--------
89.24
----------------
73.14
16.10 =
_ ***
Building complies
with Computer Performance
_
-----------------------------------------------------------------
-----------------------------------------------------------------
*** HERS Verification
Required
for Compliance
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2
Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-1R
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
GENERAL INFORMATION
HERS Verification.......... Required
Conditioned Floor Area..... 2758 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Fuel Type ................. NaturalGas
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... FullYear
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U-factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Slab On Grade
2
27580 cf
2758 sf
24.3 % of floor area
0.34 Btu/hr-sf-F
0.31
10 ft
BUILDING ZONE
INFORMATION
Floor
-------------------------
# of
# of
Cond-
Thermo-
Vent
Vent
Verified
Area
Volume
Dwell
Peop-
it-
stat
Height
Area
Leakage or
Zone Type
--------------
(sf)
-----
(cf)
------
Units
-----
le
-----
ioned
-----
Type
--------
(ft)
-----
(sf)
-------
Housewrap
----------
HOUSE
Residence
2503
25030
0.80
3.2
Yes
Setback
2.0
Standard
No
CASITA
Residence
255
2550
0.20
0.8
Yes
Setback
2.0
Standard
No
OPAQUE SURFACES
U-
Sheath-
Solar
Appendix
Frame
Area
fact-
Cavity
ing
Act
Gains
IV
Location/
Surface
------------
Type
(sf)
or
R-val
R-val
Azm
Tilt
Reference
Comments
HOUSE
-----
----
-----
-----
-----
---
----
---
---------
--------------
1
Wall
Wood
396
0.102
13
0
180
90
Yes
IV.9 A3
SOUTH
3
Wall
Wood
213
0.102
13
0
270
90
Yes
IV.9 A3
WEST
5
Wall
Wood
483
0.102
13
0
0
90
Yes
IV.9 A3
NORTH
7
Wall
Wood
468
0.102
13
0
90
90
Yes
IV.9 A3
EAST
9
Wall
Wood
36
0.102
13
0
315
90
Yes
IV.9 A3
NORTHWEST
10
Wall
Wood
582
0.102
13
0
0
90
No
IV.9 A3
GARAGE WALL
11
RoofRad
Wood
2477
0.025
38
0
n/a
0
Yes
IV.1 A18
Attic
13
Door
Wood
20
0.387
0
0
315
90
Yes
None
Wood Door
14
Door
Wood
18
0.387
0
0
0
90
No
None
Wood Door
CASITA
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3
Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46
MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
OPAQUE SURFACES
U- Sheath- Solar Appendix
Frame Area fact- Cavity ing Act Gains IV Location/
Surface Type (sf) or R-val R-val Azm Tilt Reference Comments
------------ ----- ---- ----- ----- ----- --- ---- --------------------------
2 Wall Wood 122 0.102 13 0 180 90 Yes IV.9 A3 SOUTH
4 Wall Wood 139 0.102 13 0 270 90 Yes IV.9 A3 WEST
6 Wall Wood 152 0.102 13 0 0 90 Yes IV.9 A3 NORTH
8 Wall Wood 145 0.102 13 0 90 90 Yes IV.9 A3 EAST
12 RoofRad Wood 255 0.025 38 0 n/a 0 Yes IV.1 A18 Attic
PERIMETER LOSSES
----------------
Appendix
Length F2 Insul Solar IV Location/
Surface (ft) Factor R-val Gains Reference Comments
------------ --------------------- -------------- ----------------------
HOUSE
15 SlabEdge 215 0.900 R-0 No None To Outside
17 SlabEdge 60 0.550 R-0 No None TO GARAGE
.CASITA
16 SlabEdge 63 0.900 R-0 No None To Outside
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
------------------ --=-- ----- ----- --- ------------ ------------------------
unrlc V
1
Wind
Back
(S)
36.0
0.340
0.300
180
90
2
Wind
Back
(S)
30.0
0.340
0.300
180
90
3
Door
Back
(S)
48.0
0.340
0.310
180
90
5
Door
Right
(W)
40.0
0.340
0.310
270
90
6
Wind
Right
(W)
2.3
0.340
0.330
270
90
7
Wind
Right
(W)
2.3
0.340
0.330
270
90
8
Wind
Right
(W)
2.3
0.340
0.330
270
90
10
Wind
Front
(N)
24.0
0.340
0.300
0
90
11
Wind
Front
(N)
24.0
0.340
0.300
0
90
12
Door
Front
(N)
21.5
0.340
0.310
0
90
13
Wind
Front
(N)
6.0
0.340
0.300
0
90
14
Wind
Front
(N)
40.0
0.340
0.300
0
90
15
Wind
Front
(N)
10.0
0.340
0.330
0
90
16
Door
Front
(N)
24.0
0.340
0.310
0
90
17
Door
Front
(N)
48.0
0.340
0.310
0
90
19
Wind
Left
(E)
20.0
0.340
0.300
90
90
20
Wind
Left
(E)
12.0
0.340
0.300
90
90
21
Door
Left
(E)
48.0
0.340
0.310
90
90
22
Wind
Left
(E)
12.0
0.340
0.300
90
90
Standard SGLASSI/Vinyl/Operable W
Standard SGLASS2/Vinyl/Operable W
Standard SGLASS3/French Door
Standard WGLASSI/French Door
Standard WGLASS2/Vinyl/Fixed Wind
Standard WGLASS3/Vinyl/Fixed Wind
Standard WGLASS4/Vinyl/Fixed Wind
Standard NGLASSI/Vinyl/Operable W
Standard NGLASS2/Vinyl/Operable W
Standard NGLASS3/French Door
Standard NGLASS4/Vinyl/Operable W
Standard NGLASSS/Vinyl/Operable W
Standard NGLASS6/Vinyl/Fixed Wind
Standard NGLASS7/French Door
Standard NGLASS8/Vinyl/Sliding G1
Standard EGLASSI/Vinyl/Operable W
Standard SGLASS2/Vinyl/Operable W
Standard SGLASS3/French Door
Standard EGLASS4/Vinyl/Operable W
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4
Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46
I MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-1R
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
------------------ ----- ----- ----- --- ------------ ------------------------
23 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASSS/Vinyl/Operable W
24 Wind Left (E) 48.0 0.340 0.330 90 90 Standard EGLASS6/Vinyl/Fixed Wind
25 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS7/Vinyl/Operable W
26 Wind Left (E) 24.0 0.340 0.300 90 90 Standard EGLASS8/Vinyl/Operable W
27 Wind Left (E) 24.0 0.340 0.300 90 90 Standard EGLASS9/Vinyl/Operable W
28 Wind Left (E) 20.0 0.340 0.300 90 90 Standard EGLASS10/Vinyl/Operable
29 Wind Right (NW) 9.0 0.340 0.330 315 90 Standard NWGLASSI/Vinyl/Fixed Win
CASITA
4 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS4/Vinyl/Sliding Gl
9 Wind Right (W) 6.0 0.340 0.300 270 90 Standard WGLASSS/Vinyl/Operable W
18 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS9/Vinyl/Operable W
OVERHANGS
---Window--- ------------ Overhang ------------
Area Left Right
Surface (sf) Width Height Depth Height Extension Extension
----------- ----- ----- ------ ----- ------ --------- ---------
HOUSE
1 Window 36.0 6.00 6.00 1.00 0.50 n/a n/a
2 Window 30.0 6.00 5.00 1.00 0.50 n/a n/a
3 Door 48.0 6.00 8.00 10.0 0.50 n/a n/a
5 Door 40.0 5.00 8.00 3.00 0.50 n/a n/a
14 Window 40.0 5.00 8.00 7.00 0.50 n/a n/a
16 Door 24.0 3.00 8.00 8.00 0.50 n/a n/a
17 Door 48.0 6.00 8.00 8.00 0.50 n/a n/a
19 Window 20.0 5.00 4.00 8.00 1.00 n/a n/a
23 Window 12.0 2.00 6.00 8.00 1.00 n/a n/a
24 Window 48.0 6.00 8.00 8.00 1.00 n/a n/a
25 Window 12.0 2.00 6.00 8.00 1.00 n/a n/a
29 Window 9.0 1.50 6.00 6.00 1.00 n/a n/a
SLAB SURFACES
-------------
Area
Slab Type (sf)
HOUSE
Standard Slab 2503
CASITA
Standard Slab 255
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5
Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-lR
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
HVAC SYSTEMS
------------
Verified
Number
Verified
Verified
Verified
Verified
Maximum
System
of
Minimum
Refrig Charge
Adequate
Fan Watt
Cooling
Type
------------
Systems
-------
Efficiency
-----------
EER
or TXV
Airflow
Draw
Capacity
HOUSE
-----
-------------
--------
--------
--------
Furnace
1
0.800 AFUE
n/a
n/a
n/a
n/a
n/a
ACSplit
1
14.00 SEER
11.5
Yes
No
No
No
CASITA
HPSplit
1
7.70 HSPF
n/a
n/a
n/a
n/a
n/a
HPSplit
1
14.00 SEER
11.5
Yes
No
No
No
HVAC SIZING
Verified
Total Sensible Design .Maximum
Heating Cooling Cooling Cooling
System Load Load Capacity Capacity
Type (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr)
-----------------------------------------------------
HOUSE
Furnace 49510 n/a n/a n/a
ACSplit n/a 39032 48439 n/a
CASITA
HPSplit 8699 n/a n/a n/a
HPSplit n/a 6411 7956 n/a
-----------------------------------------------------
Total 58209 45444 56395 n/a
Orientation of Maximum..... Front Facing 90 deg (E)
Sizing Location............ LA QUINTA
Winter Outside Design...... 26 F
Winter Inside Design....... 70 F
Summer Outside Design...... 111 F
Summer Inside Design....... 75 F
Summer Range ............... 34 F
DUCT SYSTEMS
------------
Verified Verified Verified
System Duct Duct Duct Surface Buried
Type Location R-value Leakage Area Ducts
-------------------------------------------------------
HOUSE
Furnace Attic R-6 Yes No No
ACSplit Attic R-6 Yes No No
CASITA
HPSplit Attic R-6 Yes No No
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6
Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46
MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-lR
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
DUCT SYSTEMS
------------
Verified Verified Verified
System Duct Duct Duct Surface Buried
Type Location R-value Leakage Area Ducts
-------------------------------------------------------
HPSplit Attic R-6 Yes No No
WATER HEATING SYSTEMS
---------------------
Number Tank External
Heater in Energy Size Insulation
Tank Type Type Distribution Type System Factor (gal) R-value
------------------------------------------- - ------------ ----------------
1 Storage Gas Standard 1 0.62 50 R- n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates HERS verified Insulation Installation.
This building incorporates a HERS verified Refrigerant Charge test
or a HERS verified Thermostatic Expansion Valve (TXV). If a
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified EER.
This building incorporates HERS verified Duct Leakage.
This is a multiple orientation building. This printout is for the front
facing North.
This building incorporates a Radiant Barrier.
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-4R installation certificate. ***
This building incorporates HERS verified Insulation Installation.
This building incorporates a HERS verified Refrigerant Charge test
or a HERS verified Thermostatic Expansion Valve (TXV). If a
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7
-------------------------------------------------------------------------------
Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46
I MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-lR
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
HERS REQUIRED VERIFICATION
--------------------------
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified EER.
This building incorporates HERS verified Duct Leakage. Target leakage is
calculated and documented on the CF-4R. If the measured CFM is above the
target, then corrective action must be taken to reduce the duct leakage and
then must be retested. Alternatively, the compliance calculations could be
redone without duct testing. If ducts are not installed, then HERS
verification is not necessary.
REMARKS
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 8
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-lR
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title-24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility.
DESIGNER or OWNER
Name.... Kyle Tibbitts
Company. Shea Homes/Trilogy
Address. 60946 Desert Rose
La Quinta, CA 92253
Phone... (760) 777-6026
License. 6
Signed.. 7j-y-O p
(date)
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed.
(date)
DOCUMENTATION AUTHOR
Name.... Chinh Nguyen
Company. Westpac Air Conditioning, Inc.
Address. 1610 N. Maple St.
Corona, CA 92880
Phone... (951)n739-9501
Signed..
(date)
MANDATORY MEASURES CHECKLIST: RESIDENTIAL
MF-1R
Page 1
Project Title..........
Plan 6420/OptBay2/Casita.
Date..02/27/08 10:50:46
Project Address........
******* ---------------------
La Quinta, CA
*v7.10* I
I
Documentation Author...
Chinh Nguyen
******* I Building Permit
# I
Westpac Air Conditioning,
Inc. I
1
1610 N. Maple St.
I Plan Check /
Date I
Corona, CA 92880
I
1
(951) 739-9501
I Field Check/
Date I
Climate Zone...........
15
---------------------
Compliance Method......
MICROPAS7 v7.10 for 2005
Standards by Enercomp,
Inc.
I MICROPAS7 v7.10
File-T6420CST Wth-CTZ15S05 Program -FORM MF-1R
I User#-MP2387 User-Westpac
-------------------------------------------------------------------------------
Air Conditioning, Run -Trilogy at La Quinta
P-3 I
Note: Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supersede the items marked with
an asterisk (*). When this checklist is incorporated into the permit documents,
the features noted shall be considered by all parties as minimum component
performance specifications for the mandatory measures whether they are shown
elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
De- En-
sign- force-
n/a er ment
*150(a): Minimum R-19 insulation in wood framed ceiling or
equivalent U-factor in metal frame ceiling
—
150(b): Loose fill insulation manufacturer's labeled R-Value
*150(c): Minimum R-13 wall insulation in wood framed walls or
_
equivalent U-factor in metal frame walls (does not apply
to exterior mass walls)
*150(d): Minimum R-13 raised floor insulation in framed floors
�.
or equivalent U-factor
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door covering the entire
opening of the firebox
b. Outside air intake with damper and control, flue
_
damper and control
2. No continuous burning gas pilot lights allowed
_
150(f): Air retarding wrap installed to comply with Sec. 151
meets requirements specified in ACM Residential Manual
150(g): Vapor barriers mandatory in Climate Zones 14,16 only
150(1): Slab edge insulation - water absorption rate for the
insulation material without facings no greater than 0.3%,
water vapor permeance rate no greater than 2.0 perm/inch
118: Insulation specified or installed meets insulation quality
standards. Indicate type and include CF-6R form
116-17: Fenestration Products, Exterior Doors and Infiltration/
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage
2. Fenestration products (except field -fabricated) have
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 2
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM MF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
label with certified U-factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En-
sign- force
n/a er ment
110-113: HVAC equipment, water heaters, showerheads and
faucets certified by the Energy Commission
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA
150(i): Setback thermostat on all applicable heating and/or
cooling systems
150(j): Water system pipe and tank insulation and cooling
systems line insulation
1. Storage gas water heaters rated with an Energy Factor
less than 0.58 must be externally wrapped with insulation
having an installed thermal resistance of R12 or greater
2. Back-up tanks for solar system, unfired storage tanks, or
other indirect hot water tanks have R-12 external
insulation or R-16 internal and indicated on the
exterior of the tank showing the R-value
3. The following piping is insulated according to Table 150-A/B
or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to
water heater tank, non -recirculating systems, and
entire length of recirculating sections of hot water
pipes shall be insulated to Table 150B
2. Cooling system piping (suction, chilled water, or
brine lines), piping insulated between heating source
and indirect hot water tank shall be insulated to
Table 150-B and Equation 150-A
4. Steam hydronic heating systems or hot water systems >15 psi,
meet requirements of Table 123-A
5. Insulation must be protected from damage, including that due
to sunlight, moisture, equipment maintenance and wind .
6. Insulation for chilled water piping and refrigerant suction
piping includes a vapor retardant or is enclosed entirely
in conditioned space
7. Solar water -heating systems/collectors are certified by the
Solar Rating and Certification Corporation
*150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to
.meet the requirements of the CMC Sections 601, 602, 603,
604, 605 and Standard 6-5; supply -air and return -air ducts
and plenums are insulated to a minimum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings
shall be sealed with mastic, tape, or other duct -closure
system that meets the applicable requirements of UL 181,
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 3
Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM MF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
UL 181A, or UL 181B or aerosol sealant that meets the
requirements of UL 723. If mastic or tape is used to seal
openings greater than 1/4 inch, the combination of mastic
/
and either mesh or tape shall be used
2.
Building cavities, support platforms for air handlers, and
plenums defined or constructed with materials other than
sealed sheet metal, duct board or flexible duct shall not
be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in
cavities and support platforms shall not be compressed to cause
reductions in the cross -sectional area of the ducts
3.
Joints and seams of duct systems and their components
shall not be sealed with cloth backed rubber adhesive
duct tapes unless such tape is used in combination with
/
mastic and draw bands
4.
Exhaust fan systems have back draft or automatic dampers
5.
Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
operated dampers
6.
Protection of Insulation. Insulation shall be protected
from damage due to sunlight, moisture, equipment mainten-
ance and wind. Cellular foam insulation shall be protected
as above or painted with a coating that is water retardant
and provides shielding from solar radiation that can cause
degradation of the material
7.
Flexible ducts cannot have porous inner cores
114:
Pool and Spa Heating Systems and Equipment
1.
A thermal efficiency that complies with the Appliance
Efficiency Regulations, on -off switch mounted outside of
the heater we th r r f t' t t'
, a e p o0 opera ing ins ruc ions, --
electric resistance heating and no pilot light
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for future solar heating /
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch
115: Gas -fired central furnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
pilot light (Exception: Non -electrical cooking appliances
with pilot < 150 Btu/hr)
118(i): Cool Roof material meets specified criteria
RESIDENTIAL LIGHTING MEASURES De- En-
sign- force
n/a er ment
150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID:
contain only high efficacy lamps as outlined in Table
150-C, and do not contain a medium screw base socket
(E24/E26). Ballast for lamps 13 watts or greater are electronic
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR
Page 4
Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46
MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM MF-lR
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
----------------- =-------------------------------------------------------------
and have an output frequency no less than 20 kHz
150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain
only high efficacy lamps as outlined in Table 150-C,
luminaire has factory installed HID ballast
150(k)2: Permanently installed luminaires in kitchens shall
be high efficacy luminaires. Up to 50 percent of the wattage,
as determined in Sec. 130(c), of permanently installed luminaires
in kitchens may be in luminaires that are not high efficacy
luminaires, provided that these luminaires are controlled
by switches separate from those controlling the high
efficacy luminaires
150(k)3: Permanently installed luminaires in bathrooms,
garages, laundry rooms, utility rooms shall be high
efficacy luminaires OR are controlled by an occupant
sensor(s) certified to comply with Section 119(d) that
/
does not turn on automatically or have an always on option
150(k)4: Permanently installed luminaires located other than
in kitchens, bathrooms, garages, laundry rooms, and utility
rooms shall be high efficacy luminaires (except closets
less than 70 ft2), OR are controlled by a dimmer switch
OR are controlled by an occupant sensor(s) that complies
with Section 119(d) that does not turn on automatically
or have an always on option
150(k)5: Luminaires that are recessed into insulated ceilings
are approved for zero clearance insulation cover (IC) and
are certified air tight to ASTM E283 and labeled as air
j
tight (AT) to less than 2.0 CFM at 75 Pascals
150(k)6: Luminaires providing outdoor lighting and permanently
mounted to a residential building or to other buildings on
the same lot shall be high efficacy luminaires (not in-
cluding lighting around swimming pools/water features or
other Article 680 locations) OR are controlled by occupant
sensors with integral photo control certified to comply
with Section 119(d)
150(k)7: Lighting for parking lots for 8 or more vehicles shall
have lighting that complies with Sec. 130, 132, and 147.
Lighting for parking garages for 8 or more vehicles shall
have lighting that complies with Sec. 130, 131, and 146
150(k)8: Permanently installed lighting in the enclosed, non -
dwelling spaces of low-rise residential buildings with four
or more dwelling units shall be high efficacy luminaires OR ;
are controlled by an occupant sensor(s) certified to
comply with Section 119(d)
SHEA HOMES
PRODUCT-3
TRILOGY AT LA QUINTA
PLAN -643 0
Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
CF-lR
Page 1
Project Title..........
Plan 6430 Standard Date..02/27/08 10:52:02
Project Address........
******* ---------------------
La Quinta, CA *v7.10* I
I
Documentation Author...
Chinh Nguyen ******* I
Building Permit # I
Westpac Air Conditioning, Inc. I
1
1610 N. Maple St. I
Plan Check /
Date I
Corona, CA 92880 I
1
(951) 739-9501 I
Field Check/
Date
Climate Zone...........
15 ---------------------
Compliance Method......
-------------------------------------------------------------------------------
MICROPAS7 v7.10 for 2005 Standards by Enercomp,
Inc.
-------------------------------------------------------------------------------
I MICROPAS7 v7.10
File-TRI_6430 Wth-CTZ15S05 Program
-FORM CF-1R
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy
-------------------------------------------------------------------------------
at La Quinta
.P-3 I
----------------------------
----------------------------
MICROPAS7 ENERGY USE SUMMARY
= Energy
Use
Standard
Proposed Compliance =
_ (kTDV/sf-yr)
------------------------
----------
Design
Design
--------------------
Margin =
= Space
Heating
2.30
1.88
0.42 =
= Space
Cooling..........
74.93
56.14
18.79 =
= Water.Heating..........
9.28
8.57
0.71 =
=
North Total
86.51
66.59
19.92 =
= Space
Heating..........
2.30
2.37
-0.07 =
= Space
Cooling..........
74.93
58.78
16.15 =
= Water
Heating..........
9.28
8.57
0.71 =
=
East Total
86.51
69.72
16.79 =
- Space
Heating..........
2.30
2.76
-0.46 =
- Space
Cooling
74.93
54.58
20.35 =
= Water
Heating..........
9.28
8.57
0.71 =
=
South Total
86.51
65.91
20.60 =
- Space
Heating..........
2.30
2.26
0.04 =
- Space
Cooling..........
74.93
57.07
17.86 =
= Water
_
Heating..........
9.28
8.57
0.71 =
=
West Total
--------
86.51
----------------
67.90
-
18.61 =
_ ***
Building complies
with Computer Performance
_ *** HERS Verification
Required
for Compliance
*** _
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02
I MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM CF-1R
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
GENERAL INFORMATION
HERS Verification.......... Required
Conditioned Floor Area..... 2769 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Fuel Type ................. NaturalGas
Building Front Orientation. Cardinal - N,E.,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... FullYear
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U-factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Slab On Grade
1
27690 cf
2769 sf
22.1 % of floor area
0.34 Btu/hr-sf-F
0.31
10 ft
BUILDING ZONE INFORMATION
-------------------------
Floor # of # of Cond- Thermo- Vent Vent Verified
Area Volume Dwell Peop- it- stat Height Area Leakage or
Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap
-------------- ----- ------ ----- ----- ------------- ----- ------- ----------
Residence 2769 27690 1.00 4.0 Yes Setback 2.0 Standard No
OPAQUE SURFACES
U-
Sheath-
Solar
Appendix
Frame
Area
fact-
Cavity
ing
Act
Gains
IV
Location/
Surface
Type
(sf)
or
R-val
R-val
Azm
Tilt
Reference
Comments
------------
1
Wall
-----
Wood
----
406
-----
0.102
-----
13
-----
0
---
180
----
90
---
Yes
---------
IV.9
A3
--------------
SOUTH
2
Wall
Wood
512
0.102
13
0
270
90
Yes
IV.9
A3
WEST
3
Wall
Wood
320
0.102
13
0
0
90
Yes
IV.9
A3
NORTH
4
Wall
Wood
614
0.102
13
0
90
90
Yes
IV.9
A3
EAST
5
Wall
Wood
18
0.102
13
0
135
90
Yes
IV.9
A3
SOUTHEAST
6
Wall
Wood
18
0.102
13
0
225
90
Yes
IV.9
A3
SOUTHWEST
7
Wall
Wood
532
0.102
13
0
0
90
No
IV.9
A3
GARAGE WALL
8
RoofRad
Wood
2769
0.025
38
0
n/a
0
Yes
IV.1
A18
Attic
9
Door
Wood
20
0.387
0
0
0
90
Yes
None
Wood Door
10
Door
Wood
18
0.387
0
0
0
90
No
None
Wood Door
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02
-----------------------------=-------------------------------------------------
-------------------------------------------------------------------------------
I MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM CF-lR I
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
PERIMETER LOSSES
----------------
Appendix
Length
F2
Insul
Solar
IV
Location/
Surface
(ft)
Factor
R-val
Gains
Reference
Comments
------------
11 SlabEdge
------
252
--------
0.900
-------
R-0
-----
No
---------
None
----------------------
To Outside
12 SlabEdge
55
0.550
R-0
No
None
TO GARAGE
FENESTRATION SURFACES
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
------------------ ----- ----- ----- --- ------------ ------------------------
1 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASSI/Vinyl/Operable W
2 Wind Back (S) 36.0 0.340 0.330 180 90 Standard SGLASS2/Vinyl/Fixed Wind
3 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS3/Vinyl/Operable W
4 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS4/Vinyl/Sliding G1
5 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS5/Vinyl/Operable W
6 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS6/Vinyl/Operable W
7 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASSI/French Door
8 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS8/Vinyl/Operable W
9 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS9/Vinyl/Operable W
10 Wind Back (S) 36.0 0.340 0.330 180 90 Standard SGLASS10/Vinyl/Fixed Win
11 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASSII/Vinyl/Operable
12 Wind Right (W) 12.0 0.340 0.300 270 90 Standard WGLASSI/Vinyl/Operable W
13 Wind Right (W) 12.0 0.340 0.300 270 90 Standard WGLASS2/Vinyl/Operable W
14 Wind Right (W) 4.0 0.340 0.300 270 90 Standard WGLASS3/Vinyl/Operable W
15 Wind Right (W) 20.0 0.340 0.300 270 90 Standard WGLASS4/Vinyl/Operable W
16 Wind Front (N) 24.0 0.340 0.300 0 90 Standard NGLASSI/Vinyl/Operable W
17 Wind Front (N) 6.0 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind
18 Wind Front (N) 15.0 0.340 0.300 0 90 Standard NGLASS3/Vinyl/Operable W
19 Wind Front (N) 15.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W
20 Wind Front (N) 12.0 0.340 0.300 0 90 Standard NGLASS5/Vinyl/Operable W
21 Wind Front (N) 36.0 0.340 0.330 0 90 Standard NGLASS6/Vinyl/Fixed Wind
22 Wind Front (N) 12.0 0.340 0.300 0 .90 Standard NGLASSI/Vinyl/Operable W
23 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W
24 Wind Left (E) 18.0 0.340 0.300 90 90 Standard SGLASS2/Vinyl/Operable W
25 Wind Left (E) 4.0 0.340 0.300 90 90 Standard EGLASS3/Vinyl/Operable W
26 Wind Left (E) 8.0 0.340 0.300 90 90 Standard SGLASS4/Vinyl/Operable W
27 Door Left (E) 48.0 0.340 0.310 90 90 Standard EGLASS5/Vinyl/Sliding Gl
28 Wind Left (SE) 12.0 0.340 0.330 135 90 Standard SEGLASSI/Vinyl/Fixed Win
29 Wind Back (SW) 12.0 0.340 0.330 225 90 Standard SWGLASSI/Vinyl/Fixed Win
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4
Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM CF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
OVERHANGS
---Window---
------------
Overhang ------------
Area
Left
Right
Surface
(sf)
Width
Height
Depth
Height
Extension Extension
-----------
4
Door
-----
48.0
-----
6.00
------
8.00
-----
5.00
------
0.50
------------------
n/a
n/a
5
Window
36.0
6.00
6.00
6.00
0.50
n/a
n/a
6
Window
36.0
6.00
6.00
6.00
0.50
n/a
n/a
9
Window
12.0
2.00
6.00
8.00
0.50
n/a
n/a
10
Window
36.0
6.00
6.00
8.00
0.50
n/a
n/a
11
Window
12.0
2.00
6.00
8.00
0.50
n/a
n/a
17
Window
6.0
1.00
6.00
5.00
0.50
n/a
n/a
20
Window
12.0
2.00
6.00
8.00
0.50
n/a
n/a
21
Window
36.0
6.00
6.00
8.00
0.50
n/a
n/a
22
Window
12.0
2.00
6.00
8.00
0.50
n/a
n/a
23
Window
18.0
3.00
6.00
6.00
1.00
n/a
n/a
27
Door
48.0
6.00
8.00
10.0
1.00
n/a
n/a
28
Window
12.0
2.00
6.00
5.00
1.00
n/a
n/a
29
Window
12.0
2.00
6.00
5.00
1.00
n/a
n/a
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
Standard Slab 2769
HVAC SYSTEMS
------------
Verified
Number
Verified
Verified
Verified
Verified
Maximum
System
of
Minimum
Refrig Charge
Adequate
Fan Watt
Cooling
Type
------------
Systems
Efficiency EER
or TXV
Airflow
Draw
Capacity
Furnace
-------
1
----------- -----
0.800 AFUE n/a
-------------
n/a
--------
n/a
--------
n/a
--------
n/a
ACSplit
1
14.00 SEER 11.5
Yes
No
No
No
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM CF-lR
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
HVAC SIZING
Verified
Total
Sensible
Design
Maximum
Heating
Cooling
Cooling
Cooling
System
Load
Load
Capacity
Capacity
Type
-------------
(Btu/hr)
----------
(Btu/hr)
----------
(Btu/hr)
----------
(Btu/hr)
----------
Furnace
54249
n/a
n/a
n/a
ACSplit
n/a
42766
53072
n/a
Orientation of Maximum.....
Sizing Location............
Winter Outside Design......
Winter Inside Design.......
Summer Outside Design......
Summer Inside Design.......
Summer Range. ............
Front Facing 90 deg (E)
LA QUINTA
26 F
70 F
111 F
75 F
34 F
DUCT SYSTEMS
------------
Verified Verified Verified
System Duct Duct Duct Surface Buried
Type Location R-value Leakage Area Ducts
-------------------------------------------------------
Furnace Attic R-6 Yes No No
ACSplit Attic R-6 Yes No No
WATER HEATING SYSTEMS
---------------------
Number Tank External
Heater in Energy Size Insulation
Tank Type Type Distribution Type System Factor (gal) R-value
------------------------------------------- -------------- ----------------
1 Storage Gas Standard 1 0.62 50 R- n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates HERS verified Insulation Installation.
This building incorporates a HERS verified Refrigerant Charge test
or a HERS verified Thermostatic Expansion Valve (TXV). If a
cooling system is not installed, then HERS verification is not necessary
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02
-----------------------------=------------------=------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM CF-lR
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
This building incorporates HERS verified EER.
This building incorporates HERS verified Duct Leakage.
This is a multiple orientation building. This printout is for the front
facing North.
This building incorporates a Radiant Barrier.
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-4R installation certificate. ***
This building incorporates HERS verified Insulation Installation.
This building incorporates a HERS verified Refrigerant Charge test
or a HERS verified Thermostatic Expansion Valve (TXV). If a
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified EER.
This building incorporates HERS verified Duct Leakage. Target leakage is
calculated and documented on the CF-4R. If the measured CFM is above the
target, then corrective action must be taken to reduce the duct leakage and
then must be retested. Alternatively, the compliance calculations could be
redone without duct testing. If ducts are not installed, then HERS
verification is not necessary.
REMARKS
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 7
Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM CF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title-24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility.
DESIGNER or OWNER
Name.... Kyle Tibbitts
Company. Shea Homes/Trilogy
Address. 81-260 Avenue 62
La Quinta, CA 92253
Phone... (760) 777-6026
License. �ZZQ
Signed.. f [�
(date)
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed..
(date)
DOCUMENTATION AUTHOR
Name.... Chinh Nguyen
Company. Westpac Air Conditioning, Inc.
Address. 1610 N. Maple St.
Corona, CA 92880
Phone... (951) 739-9501
Signed.. 17—
(date)
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 1
-------------------------------------------------------------------------------
Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02
Project Address........ ******* ---------------------
La Quinta, CA *v7.10*
Documentation Author... Chinh Nguyen *******
Westpac Air Conditioning, Inc.
1610 N. Maple St.
Corona, CA 92880
(951) 739-9501
Building Permit #
Plan Check / Date
Field Check/ Date
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, .Inc.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM MF-lR
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I
-------------------------------------------------------------------------------
Note: Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supersede the items marked with
an asterisk (*). When this checklist is incorporated into the permit documents,
the features noted shall be considered by all parties as minimum component
performance specifications for the mandatory measures whether they are shown
elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
De- En-
sign- force-
n/a er ment
*150(a): Minimum R-19 insulation in wood framed ceiling or
equivalent U-factor in metal frame ceiling
//3a
150(b): Loose fill insulation manufacturer's labeled R-Value
*150(c): Minimum R-13 wall insulation in wood framed walls or
equivalent U-factor in metal frame walls (does not apply
to exterior mass walls)
*150(d): Minimum R-13 raised floor insulation in framed floors
or equivalent U-factor
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door covering the entire
opening of the firebox
b. Outside air intake with damper and control, flue
damper and control
2. No continuous burning gas pilot lights allowed
150(f): Air retarding wrap installed to comply with Sec. 151
meets requirements specified in ACM Residential Manual
150(g): Vapor barriers mandatory in Climate Zones 14,16 only
150(1): Slab edge insulation - water absorption rate for the
insulation material without facings no greater than 0.30,
water vapor permeance rate no greater than 2.0 perm/inch
118: Insulation specified or installed meets insulation quality
standards. Indicate type -and include CF-6R form
116-17: Fenestration Products, Exterior Doors and Infiltration
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage
2. Fenestration products (except field -fabricated) have
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 2
Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM MF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3
-------------------------------------------------------------------------------
label with certified U-factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
De- En-
sign- force
n/a
er ment
110-113: HVAC equipment, water heaters, showerheads and
faucets certified by the Energy Commission
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA
/
150(i): Setback thermostat on all applicable heating and/or
/
cooling systems
150(j): Water system pipe and tank insulation and cooling
systems line insulation
1. Storage gas water heaters rated with an Energy Factor
less than 0.58 must be externally wrapped with insulation
/
having an installed thermal resistance of R12 or greater
2. Back-up tanks for solar system, unfired storage tanks, or
other indirect hot water tanks have R-12 external
insulation or R-16 internal and indicated on the
exterior of the tank showing the R-value
3. The following piping is insulated according to Table 150-A/B
or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to
water heater tank, non -recirculating systems, and
entire length of recirculating sections of hot water
/
pipes shall be insulated to Table 150B
2. Cooling system piping (suction, chilled water, or
brine lines), piping insulated between heating source
and indirect hot water tank shall be insulated to
/
Table 150-B and Equation 150-A
4. Steam hydronic heating systems or hot water systems >15 psi,
meet requirements of Table 123-A
.5. Insulation must be protected from damage, including that due
to sunlight, moisture, equipment maintenance and wind
6. Insulation for chilled water piping and refrigerant suction
piping includes a vapor retardant or is enclosed entirely
in conditioned space
7. Solar water -heating systems/collectors are certified by t
Solar Rating and Certification Corporation
*150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to
meet the requirements of the CMC Sections 601., 602, 603,
604, 605 and Standard 6-5; supply -air and return -air ducts
and plenums are insulated to a minimum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings
shall be sealed with mastic, tape, or other duct -closure
system that meets the applicable requirements of UL 181,
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 3
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM MF-1R
User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3
------------- -----------------------------------------------------------------
UL 181A, or UL 181B or aerosol sealant that meets the
requirements of UL 723. If mastic or tape is used to seal
openings greater than 1/4 inch, the combination of mastic
and either mesh or tape shall be used
2. Building cavities, support platforms for air handlers, and
plenums defined or constructed with materials other than
sealed sheet metal, duct board or flexible duct shall not
be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in
cavities and support platforms shall not be compressed to
reductions in the cross -sectional area of the ducts _
3. Joints and seams of duct systems and their components
shall not be sealed with cloth backed rubber adhesive
duct tapes unless such tape is used in combination with
mastic and draw bands _
4. Exhaust fan systems have back draft or automatic dampers_
5. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
operated dampers _
6. Protection of Insulation. Insulation shall be protected
from damage due to sunlight, moisture, equipment mainten-
ance and wind. Cellular foam insulation shall be protectec
as above or painted with a coating that is water retardant
and provides shielding from solar radiation that can cause
degradation of the material _
7. Flexible ducts cannot have porous inner cores _
114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance
Efficiency Regulations, on -off switch mounted outside of
the heater weather - roof o eratin instructions no
P electric resistance heating and no
pilot light
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for future solar heating /
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch
115: Gas -fired central furnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
pilot light (Exception: Non -electrical cooking appliances
with pilot < 150 Btu/hr)
118(i): Cool Roof material meets specified criteria
RESIDENTIAL LIGHTING MEASURES
n/a
150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID:
contain only high efficacy lamps as outlined in Table
150-C, and do not contain a medium screw base socket
(E24/E26). Ballast for lamps 13 watts or greater are electronic
De- En-
sign- force
er ment
MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 4
Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02-
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM
MF-1R
I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La
Quinta P-3
-------------------------------------------------------------------------------
and have an output frequency no less than 20 kHz
150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain
only high efficacy lamps as outlined in Table 150-C,
luminaire has factory installed HID ballast
150(k)2: Permanently installed luminaires in kitchens shall
be high efficacy luminaires. Up to 50 percent of the wattage,
as determined in Sec. 130(c), of permanently installed luminaires
in kitchens may be in luminaires that are not high efficacy
luminaires, provided that these luminaires are controlled
by switches separate from those controlling the high
efficacy luminaires
150(k)3: Permanently installed luminaires in bathrooms,
garages, laundry rooms, utility rooms shall be high
efficacy luminaires OR are controlled by an occupant
sensor(s) certified to comply with Section 119(d) that
does not turn on automatically or have an always on option
150(k)4: Permanently installed luminaires located other than
in kitchens, bathrooms, garages, laundry rooms, and utility
rooms shall be high efficacy luminaires (except closets
less than 70 ft2), OR are controlled by a dimmer switch
OR are controlled by an occupant sensor(s) that complies
with Section 119(d) that does not turn on automatically
or have an always on option
150(k)5: Luminaires that are recessed into insulated ceilings
are approved for zero clearance insulation cover (IC) and
are certified air tight to ASTM E283 and labeled as air
tight (AT) to less than 2.0 CFM at 75 Pascals
150(k)6: Luminaires providing outdoor lighting and permanently
mounted to a residential building or to other buildings on
the same lot shall be high efficacy luminaires (not in-
cluding lighting around swimming pools/water features or
other Article 680 locations) OR are controlled by occupant
sensors with integral photo control certified to comply
j
with Section 119(d)
150(k)7: Lighting for parking lots for 8 or more vehicles shall
have lighting that complies with Sec. 130, 132, and 147.
Lighting for parking garages for 8 or more vehicles shall
have lighting that complies with Sec. 130, 131, and 146
150(k)8: Permanently installed lighting in the enclosed, non -
dwelling spaces of low-rise residential buildings with four
or more dwelling units shall be high efficacy luminaires OR
are controlled by an occupant sensor(s) certified to
comply with Section 119(d)