Trilogy TR 30023 (Product 3) 2007 Code Update - Title 24TITLE 24 Energy Conservation Compliance Report MAR 2 0 2008 J By TRILOGY AT LA QUINTA La Quinta, California F-R-O--D'UCT--3 Prepared For SHEA HOMES 60946 Desert Rose La Quinta, CA 92253 Phone: (760) 777-6026 Date :Feb 26th, 2008 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION x^KNA%y km Oka- Ww or PA -I& EXTINDACA AIR CONDITIONING i Working As Team to Be The Best In Our Industry" Chinh Nguyen, Certified Energy Analyst 1610 N. Maple Street Corona, CA 92880-1760 (800) 700-0799 / (951) 739-9509 fax E-mail. chinh.nouven(EDwestpacair.com Table of Contents 11 -Cover Sheet -T-24 Summary report -Plan 6505 - CF-1 R Certificate of Compliance - MF-1 R Mandatory Measures Check List - Plan 6505/option Bay 2 - CF-1 R Certificate of Compliance - MF-1 R Mandatory Measures Check List - Plan 6505/option Bay 2/Casita - CF-I R Certificate of Compliance - MF-1 R Mandatory Measures Check List - Plan 6420 - CF-1 R / Certificate of Compliance - MF-1R Mandatory Measures Check List - Plan 6420/Option Bay 2 - CF-1 R / Certificate of Compliance - MF-1 R Mandatory Measures Check List - Plan 6420/Option Bay 2/Casita - CF-1 R / Certificate of Compliance - MF-1 R Mandatory Measures Check List - Plan 6430 - CF-1 R / Certificate of Compliance - MF-1 R Mandatory Measures Check List t TITLE-24 SUMMARY REPORT The Following is the requirement to exceed the 2005 Residential Energy Standards (California Code of Regulations, Title 24, Part 6 and the Administrative Regulations, Title 24, Part 1) 15% 1. R-38 Roof Insulation. 2. Radiant Barrier is Required. 3. R-13 Exterior Wall Insulation. 4. Low-e Vinyl Windows & Sliding Doors to be selected by Owner: -Operable Windows with U value of 0.34 & SHGC of 0.30 -Fixed Windows with U value of 0.34 & SHGC of 0.33 -Sliding Glasses Door with U value of 0.34 & SHGC of 0.31 5. R-6.0 Duct Insulation. 6. Gas Furnace with 80% AFUE . 7. Condenser 14.0 SEER With Minimum EER of 11.5 8. TXV Required. 9. 50 Gallons Water Heater to be selected by Owner. IO.Ducts Tested Required. I I.Quality Insulation Installation is Required. SHEA HOMES, PRODUCT-3 TRILOGY AT LA QUINTA PLAN -6505 Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 I CERTIFICATE -OF- COMPLIANCE: -RESIDENTIAL -COMPUTER -METHOD ----------CF-1R---- Page -1 ------------ Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09 Project Address........ ******* --------------------- La Quinta, CA *v7.10* II Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I I 1610 N. Maple St. I Plan Check / Date Corona, CA 92880 I (951) 739-9501 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta. P-3 I ------------------------------------------------------------------------------- MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) _----------------------- ---------- Design Design -------------------- Margin = - - Space Heating.......... 2.34 2.14 0.20 = - Space Cooling.......... 76.41 61.52 14.89 = = Water Heating.......... 10.48 9.68 0.80 = = North Total 89.23 73.34 15.89 = - Space Heating.......... 2.34 2.51 -0.17 = = Space Cooling.......... 76.41 61.98 14.43 = = Water Heating.......... 10.48 9.68 0.8.0 = = East Total 89.23 74.17 15.06 = - Space Heating.......... 2.34 2.97 -0.63 = - Space Cooling.......... 76.41 60.32 16.09 - = Water Heating.......... 10.48 9.68 0.80 - = South Total 89.23 72.97 16.26 = = Space Heating.......... 2.34 2.54 -0.20 = = Space Cooling.......... 76.41 59.28 17.13 = = Water _ Heating.......... 10.48 9.68 0.80 = = West Total -------- 89.23 ---------------- 71.50 - 17.73 = _ *** Building complies with Computer Performance _ *** HERS Verification Required for Compliance *** _ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 -- --------------------------- Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09 ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 2398 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 1 Conditioned Volume......... 23980 cf Slab -On -Grade Area......... 2398 sf Glazing Percentage......... 27.1 % of floor area Average Glazing U-factor... 0.34 Btu/hr-sf-F Average Glazing SHGC....... 0.31 Average Ceiling Height..... 10 ft BUILDING ZONE INFORMATION ------------------------- .Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ----- ------------- ----- ------- ---------- Residence 2398 23980 1.00 4.0 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 1 Wall ----- Wood ---- 344 ----- 0.102 ----- 13 ----- 0 --- 180 ---- 90 --- Yes --------- IV.9 A3 -------------- SOUTH 2 Wall Wood 376 0.102 13 0 270 90 Yes IV.9 A3 WEST 3 Wall Wood 212 0.102 13 0 0 90 Yes IV.9 A3 NORTH 4 Wall Wood 572 0.102 13 0 90 90 Yes IV.9 A3 EAST 5 Wall Wood 13 0.102 13 0 135 90 Yes IV.9 A3 SOUTHEAST 6 Wall Wood 13 0.102 13 0 225 90 Yes IV.9 A3 SOUTHWEST 7 Wall Wood 562 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 8 RoofRad Wood 2398 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 9 Door Wood 20 0.387 0 0 0 90 Yes None Wood Door 10 Door Wood 18 0.387 0 0 0 90 No None Wood Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3 Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09 MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- PERIMETER LOSSES ---------------- Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ --------------------- -------------- ---------------------- 11 S1abEdge 220 0.900 R-0 No None To Outside 12 SlabEdge 58 0.550 R-0 No None TO GARAGE FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ 1 Wind Back (S) 12.0 0.340 0.330 180 90 Standard SGLASSI/Vinyl/Fixed Wind 2 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS2/French Door 3 Wind Back (S) 12.0 0.340 0.330 180 90 Standard SGLASS3/Vinyl/Fixed Wind 4 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS4/Vinyl/Operable W 5 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS5/Vinyl/Sliding G1 6 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS6/Vinyl/Operable W 7 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS7/Vinyl/Sliding Gl 8 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS8/Vinyl/Operable W 9 Wind Right (W) 48.0 0.340 0.300 270 90 Standard WGLASSI/Vinyl/Operable W 10 Wind Right (W) 48.0 0.340 0.300 270 90 Standard WGLASS2/Vinyl/Operable W 11 Wind Right (W) 24.0 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind 12 Wind Right (W) 24.0 0.340 0.330 270 90 Standard WGLASS4/Vinyl/Fixed Wind 13 Wind Front (N) 6.0 0.340 0.330 0 90 Standard NGLASSI/Vinyl/Fixed Wind 14 Wind Front (N) 6.0 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind 15 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS3/Vinyl/Operable W 16 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W 17 Wind Left (E) 48.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W 18 Wind Left (E) 6.0 0.340 0.300 90 90 Standard EGLASS2/Vinyl/Operable W 19 Wind Left (E) 4.0 0.340 0.330 90 90 Standard EGLASS3/Vinyl/Fixed Wind 20 Wind Left (E) 10.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W 21 Wind Left (E) 20.0 0.340 0.330 90 90 Standard SGLASS5/Vinyl/Fixed Wind 22 Wind Left (E) 10.0 0.340 0.300 90 90 Standard EGLASS6/Vinyl/Operable W 23 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS7/Vinyl/Operable W 24 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS8/Vinyl/Operable W 25 Wind Left (E) 36.0 0.340 0.300 90 90 Standard EGLASS9/Vinyl/Operable W 26 Wind Left (SE) 12.0 0.340 0.330 135 90 Standard SEGLASSI/Vinyl/Fixed Win 27 Wind Back (SW) 12.0 0.340 0.330 225 90 Standard SWGLASSI/Vinyl/Fixed Win CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 ------------------------------------------------------------------------------- Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09 ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface ----------- (sf) Width Height Depth Height Extension Extension 4 Window ----- 36.0 ----- 6.00 ------ 8.00 ----- 10.0 ------ 0.25 --------- n/a --------- n/a 5 Door 48.0 6.00 8.00 10.0 0.25 n/a n/a 7 Door 48.0 6.00 8.00 10.0 0.25 n/a n/a 8 Window 36.0 6.00 8.00 10.0 0.25 n/a n/a 9 Window 48.0 6.00 8.00 10.0 0.25 n/a n/a 10 Window 48.0 6.00 8.00 10.0 0.25 n/a n/a 13 Window 6.0 1.00 6.00 7.00 0.25 n/a n/a 14 Window 6.0 1.00 6.00 7.00 0.25 n/a n/a 17 Window 48.0 6.00 8.00 7.00 0.25 n/a n/a 25 Window 36.0 6.00 8.00 10.0 0.25 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) Standard Slab 2398 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type Systems Efficiency EER or TXV Airflow Draw Capacity ------------ Furnace ------- 1 ----------- ----- 0.800 AFUE n/a ------------- n/a -------- n/a -------- n/a -------- n/a ACSplit 1 14.00 SEER 11.5 Yes No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- Furnace 49503 n/a n/a n/a ACSplit n/a 39379 48870 n/a Orientation of.Maximum..... Front Facing 180 deg (S) CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5 Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- Sizing Location.._ ........ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R-value Leakage Area Ducts ------------- ----------- ------ ------- -------- --------- Furnace Attic R-6 Yes No No ACSplit Attic R-6 Yes No No WATER HEATING SYSTEMS --------------------- Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building. incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. CERTIFICATE -OF- COMPLIANCE: -RESIDENTIAL -COMPUTER -METHOD ----------CF-lR---- Page -6 Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09 MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------ ------------------------------------------------------------ HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7 Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER Name.... Kyle Tibbitts Company. Shea Homes/Trilogy Address. 60946 Desert Rose La Quinta, CA 92253 Phone... (7�� 27�g�026 License. Signed.. 41��t S -'�-o 9 (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) Name.... Company. Address. Phone... Signed.. DOCUMENTATION AUTHOR Chinh Nguyen Westpac Air Conditioning, 1610 N. Maple St. Corona, CA 92880 (951) 739-9501 ate) Inc. MANDATORY MEASURES CHECKLIST: RESIDENTIAL ------------------------------------------------------------------------------- MF-1R Page 1 Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. 1 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 I 1 (951) 739-9501 1 Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method...... ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. 1 MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM MF-1R 1 1 User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta ------------------------------------------------------------------------------- P-3 I Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling 150(b): Loose fill insulation manufacturer's labeled R-Value _ *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls) D rl3 *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire / opening of the firebox b. Outside air intake with damper and control, flue / damper and control 2. No continuous burning gas pilot lights allowed 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF-6R form �� 116-17: Fenestration Products, Exterior Doors and Infiltration? Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 2 ------------------------------------------------------------------------------- Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM MF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En- sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or / cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction -;7,- piping includes a vapor retardant or is enclosed entirely in conditioned space 7. Solar water -heating systems/collectors are certified by t Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09 ----------------------------------------------------------------=-------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM MF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts 3. Joints and seams of duct systems and their components _ shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers — 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually / operated dampers _ 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible ducts cannot have porous inner cores _ 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions no electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating ` b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch / 115: Gas -fired central furnaces, pool heaters, spa heaters or / household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 4 Project Title.......... Plan 6505 Standard Date..02/27/08 10:39:09 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_6505 Wth-CTZ15S05 Program -FORM MF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I -----------------------------------------------------------------' and have an output frequency no less than 20 kHz ----- 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option / 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air / tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply / with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) SHEA HOMES PRODUCT-3 TRILOGY AT LA QUINTA PLAN -6505/OPT. BAY 2 Chinh Nguyen, Certified Enery Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1 ------------------------------------------------------------------------------- Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I I 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 I I (951) 739-9501 I Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- ----------------------------------------------------------------- ----------------------------------------------------------------- = MICROPAS7 ENERGY USE SUMMARY = = Energy ---------------------------- Use Standard Proposed Compliance = _ (kTDV/sf-yr) _----------------------- ---------- Design Design -------------------- Margin = - - Space Heating.......... 2.31 2.11 0.20 = - Space Cooling.......... 76.07 61.10 14.97 = = Water Heating.......... 10.43 9.63 0.80 = = North Total 88.81 72.84 15.97 = - Space Heating.......... 2.31 2.42 -0.11 = e - Space Cooling.......... 76.07 61.51 14.56 = = Water _ Heating.......... 10.43 9.63 0.80 = - = East Total -------- 88.81 ---------------- 73.56 15.25 = = Space Heating.......... 2.31 2.91 -0.60 = - Space Cooling.......... 76.07 60.11 15.96 = = Water Heating.......... 10.43 9.63 0.80 = = South Total 88.81 72.65 16.16 = = Space Heating.......... 2.31 2.51 -0.20 = = Space Cooling.......... 76.07 58.73 17.34 = = Water _ Heating.......... 10.43 -------- 9.63 0.80 = - = West Total 88.81 ---------------- 70.87 17.94 = _ *** Building complies with Computer Performance _ *** HERS Verification Required for Compliance *** _ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2 Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06 MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 2424 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 24240 cf 2424 sf 26.8 % of floor area 0.34 Btu/hr-sf-F 0.31 10 ft BUILDING ZONE INFORMATION Floor ------------------------- # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) -------------- ----- (cf) Units ------ ----- le ----- ioned ----- Type -------- (ft) ----- (sf) Housewrap ------- ---------- Residence 2424 24240 1.00 4.0 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 1 Wall ----- Wood ---- 344 ----- 0.102 ----- 13 ----- 0 --- 180 ---- 90 --- Yes --------- IV.9 A3 -------------- SOUTH 2 Wall Wood 376 0.102 13 0 270 90 Yes IV.9 A3 WEST 3 Wall Wood 212 0.102 13 0 0 90 Yes IV.9 A3 NORTH 4 Wall Wood 572 0.102 13 0 90 90 Yes IV.9 A3 EAST 5 Wall Wood 13 0.102 13 0 135 90 Yes IV.9 A3 SOUTHEAST 6 Wall Wood 13 0.102 13 0 225 90 Yes IV.9 A3 SOUTHWEST 7 Wall Wood 562 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 8 RoofRad Wood 2398 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 9 Door Wood 20 0.387 0 0 0 90 Yes None Wood Door 10 Door Wood 18 0.387 0 0 0 90 No None Wood Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- PERIMETER LOSSES ---------------- Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ 11 S1abEdge ------ 220 -------- 0.900 ------- R-0 ----- No --------- None ---------------------- To Outside 12 SlabEdge 58 0.550 R-0 No None TO GARAGE FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ 1 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASSI/Vinyl/Operable W 2 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS2/French Door 3 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS3/Vinyl/Operable W 4 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS4/Vinyl/Operable W 5 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS5/Vinyl/Sliding Gl 6 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS6/Vinyl/Operable W 7 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS7/Vinyl/Sliding G1 8 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS8/Vinyl/Operable W 9 Wind Right (W) 48.0 0.340 0.300 270 90 Standard WGLASSI/Vinyl/Operable W 10 Wind Right (W) 48.0 0.340 0.300 270 90 Standard WGLASS2/Vinyl/Operable W 11 Wind Right (W) 24.0 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind 12 Wind Right (W) 24.0 0.340 0.330 270 90 Standard WGLASS4/Vinyl/Fixed Wind 13 Wind Front (N) 6.0 0.340 0.330 0 90 Standard NGLASSI/Vinyl/Fixed Wind 14 Wind Front (N) 6.0 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind 15 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS3/Vinyl/Operable W 16 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W 17 Wind Left (E) 48.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W 18 Wind Left (E) 6.0 0.340 0.300 90 90 Standard EGLASS2/Vinyl/Operable W 19 Wind Left (E) 4.0 0.340 0.330 90 90 Standard EGLASS3/Vinyl/Fixed Wind 20 Wind Left (E) 10.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W 21 Wind Left (E) 20.0 0.340 0.330 90 90 Standard EGLASS5/Vinyl/Fixed Wind 22 Wind Left (E) 10.0 0.340 0.300 90 90 Standard EGLASS6/Vinyl/Operable W 23 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS7/Vinyl/Operable W 24 Wind Left (E) 12.0 0.340 0.300 90 90 Standard SGLASS8/Vinyl/Operable W 25 Wind Left (E) 36.0 0.340 0.300 90 90 Standard EGLASS9/Vinyl/Operable W 26 Wind Left (SE) 12.0 0.340 0.330 135 90 Standard SEGLASSI/Vinyl/Fixed Win 27 Wind Back (SW) 12.0 0.340 0.330 225 90 Standard SWGLASSI/Vinyl/Fixed Win CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4 ------------------------------------------------------------------------------- Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06 I MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- 4 Window ----- 36.0 ----- 6.00 ------ 8.00 ----- 10.0 ------ 0.25 --------- n/a --------- n/a 5 Door 48.0 6.00 8.00 10.0 0.25 n/a n/a 7 Door 48.0 6.00 8.00 10.0 0.25 n/a n/a 8 Window 36.0 6.00 8.00 10.0 0.25 n/a n/a 9 Window 48.0 6.00 8.00 10.0 0.25 n/a n/a 10 Window 48.0 6.00 8.00 10.0 0.25 n/a n/a 13 Window 6.0 1.00 6.00 6.00 0.25 n/a n/a 14 Window 6.0 1.00 6.00 6.00 0.25 n/a n/a 17 Window 48.0 6.00 8.00 4.00 0.25 n/a n/a 25 Window 36.0 6.00 8.00 10.0 0.25 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ Standard Slab 2424 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type Systems Efficiency EER or TXV ----------- Airflow Draw Capacity ------------ Furnace ------- 1 ----- ------------- 0.800 AFUE n/a n/a -------- n/a -------- n/a ------- n/a ACSplit 1 14.00 SEER 11.5 Yes No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- Furnace 49616 n/a n/a n/a ACSplit n/a 39701 49268 n/a Orientation of Maximum..... Front Facing 180 deg (S) CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R-value Leakage Area Ducts ------------------------------------------------------- Furnace Attic R-6 Yes No No ACSplit Attic R-6 Yes No No WATER HEATING SYSTEMS --------------------- Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 7 Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 ,10:41:06 I MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... Kyle Tibbitts Company. Shea Homes/Trilogy Address. 60946 Desert Rose La Quinta, CA 92253 Phone... (: , ZZ1? Q26 License. ��C.C, 5 Signed.. d (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) Name.... Chinh Nguyen Company. Westpac Air Conditioning, Inc. Address. 1610 N. Maple St. Corona, CA 92880 Phone... (951) 739-9501 Signed.. ),/� (d te) U MANDATORY MEASURES CHECKLIST: RESIDENTIAL ------------------------------------------------------------------------------- MF-lR Page 1 ------------------------------------------------------------------------------- Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I 1 1610 N. Maple St. I Plan Check/ Date I Corona, CA 92880 I 1 (951) 739-9501 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. 1 MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM MF-lR 1 1 User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta ------------------------------------------------------------------------------- P-3 I Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment i*150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling 150(b): Loose fill insulation manufacturer's labeled R-Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors ✓ /�' or e uivalent U-factor q 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed 150(f): Air retarding wrap installed to comply with Sec. 151 / meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.30, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF-6R form 116-17: Fenestration Products, Exterior Doors and Infiltration Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage �. 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 2 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-76505OB2 Wth-CTZ15S05 Program -FORM MF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES n/a 110-113: HVAC equipment, water heaters, showerheads and faucets certified -by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot, water systems >15 ps meet requirements of Table 123-A 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space 7. Solar water -heating systems/collectors are certified by the, Solar Rating and Certification Corporation *150(m): Ducts and ,Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, -z De- En- sign- force er ment MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 3 Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM MF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with / mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers / S. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually / operated dampers 6. Protection of Insulation. Insulation shall be,protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 4 Project Title.......... Plan 6505/Option Bay 2 Date..02/27/08 10:41:06 I MICROPAS7 v7.10 File-T6505OB2 Wth-CTZ15S05 Program -FORM MF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I --------------------------------------- ------------------------------- and have an output frequency no less .than 20 kHz ---- 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently —yl mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to ` comply with Section 119(d) / SHEA HOMES PRODUCT-3 TRILOGY AT LA QUINTA PLAN -6505/OPT. BAY 21CASITA Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- CF-lR Page 1 Project Title.......... Pl 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I I 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 I I (951) 739-9501 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... ------------------------------------------------------------------------------- MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy ------------------------------------------------------------------------------- at La Quinta P-3 I ---------------------------- ---------------------------- MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) _--------------------------------- Design Design -------------------- Margin = - - Space Heating.......... 2.60 2.62 -0.02 = - Space Cooling.......... 77.88 63.53 14.35 = = Water Heating.......... 9.59 8.86 0.73 = = North Total 90.07 75.01 15.06 = - Space Heating.......... 2.60 2.96 -0.36 = - Space Cooling.......... 77.88 64.42 13.46 = = Water Heating.......... 9.59 8.86 0.73 = = East Total 90.07 76.24 13.83 = - Space Heating.......... 2.60 3.40 -0.80 = - Space Cooling 77.88 61.90 15.98 = = Water Heating.......... 9.59 8.86 0.73 = = South Total 90.07 74.16 15.91 = - Space Heating.......... 2.60 2.97 -0.37 = = Space Cooling.......... 77.88 61.78 16.10 = = Water _ Heating.......... 9.59 8.86 0.73 = = West Total -------- 90.07 ---------------- 73.61 - 16.46 = _ *** Building complies with Computer Performance ----------------------------------------------------------------- ----------------------------------------------------------------- *** HERS Verification Required for Compliance CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 ------------------------------------------------------------------------------- Project Title.......... P1 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58 MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 2679 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 2 26790 cf 2679 sf 27 % of floor area 0.34 Btu/hr-sf-F 0.31 10 ft BUILDING ZONE INFORMATION Floor ------------------------- # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type -------------- (sf) ----- (cf) ------ Units ----- le ----- ioned ----- Type -------- (ft) ----- (sf) ------- Housewrap ---------- HOUSE Residence 2424 24240 0.80 3.2 Yes Setback 2.0 Standard No CASITA Residence 255 2550 0.20 0.8 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface ------------ Type (sf) or R-val R-val Azm Tilt Reference Comments HOUSE ----- ---- ----- ----- ----- --- ---- --- --------- -------------- 1 Wall Wood 344 0.102 13 0 180 90 Yes IV.9 A3 SOUTH 3 Wall Wood 376 0.102 13 0 270 90 Yes IV.9 A3 WEST 5 Wall Wood 212 0.102 13 0 0 90 Yes IV.9 A3 NORTH 7 Wall Wood 572 0.102 13 0 90 90 Yes IV.9 A3 EAST 9 Wall Wood 13 0.102 13 0 135 90 Yes IV.9 A3 SOUTHEAST 10 Wall Wood 13 0.102 13 0 225 90 Yes IV.9 A3 SOUTHWEST 11 Wall Wood 562 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 12 RoofRad Wood 2398 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 14 Door Wood 20 0.387 0 0 0 90 Yes None Wood Door 15 Door Wood 18 0.387 0 0 0 90 No None Wood Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3 Project Title.......... Pl 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58 MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface ------------ Type (sf) or R-val R-val Azm Tilt Reference Comments CASITA ----- ---- ----- ----- ----- --- ---- --- --------- -------------- 2 Wall Wood 122 0.102 13 0 180 90 Yes IV.9 A3 SOUTH 4 Wall Wood 139 0.102 13 0 270 90 Yes IV.9 A3 WEST 6 Wall Wood 152 0.102 13 0 0 90 Yes IV.9 A3 NORTH 8 Wall Wood 145 0.102 13 0 90 90 Yes IV.9 A3 EAST 13 RoofRad Wood 255 0.025 38 0 n/a 0 Yes IV.1 A18 Attic PERIMETER LOSSES Appendix Length F2 Insul Solar IV Location/ Surface ------------ (ft) ------ Factor -------- R-val Gains Reference Comments HOUSE ------- ----- --------- ---------------------- 16 SlabEdge 220 0.900 R-0 No None To Outside 18 SlabEdge 58 0.550 R-0 No None TO GARAGE CASITA 17 SlabEdge 63 0.900 R-0 No None To Outside FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------------------------------ 1 Wind Back (S) 2 Door Back (S) 3 Wind Back (S) 4 Wind Back (S) 5 Door Back (S) 6 Wind Back (S) 7 Door Back (S) 8 Wind Back (S) 10 Wind Right (W) 11 Wind Right (W) 12 Wind Right (W) 13 Wind Right (W) 15 Wind Front (N) 16 Wind Front (N) 17 Wind Front (N) 18 Wind Front (N) 20 Wind Left (E) 21 Wind Left (E) 12.0 0.340 0.330 180 90 Standard SGLASSI/Vinyl/Fixed Wind 48.0 0.340 0.310 180 90 Standard SGLASS2/French Door 12.0 0.340 0.330 180 90 Standard SGLASS3/Vinyl/Fixed Wind 36.0 0.340 0.300 180 90 Standard SGLASS4/Vinyl/Operable W 48.0 0.340 0.310 180 90 Standard SGLASSS/Vinyl/Sliding Gl 36.0 0.340 0.300 180 90 Standard SGLASS6/Vinyl/Operable W 48.0 0.340 0.310 180 90 Standard SGLASS7/Vinyl/Sliding Gl 36.0 0.340 0.300 180 90 Standard SGLASS8/Vinyl/Operable W 48.0 0.340 0.300 270 90 Standard WGLASSI/Vinyl/Operable W 48.0 0.340 0.300 270 90 Standard WGLASS2/Vinyl/Operable W 24.0 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind 24.0 0.340 0.330 270 90 Standard WGLASS4/Vinyl/Fixed Wind 6.0 0.340 0.330 0 90 Standard NGLASSI/Vinyl/Fixed Wind 6.0 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind 18.0 0.340 0.300 0 90 Standard NGLASS3/Vinyl/Operable W 18.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W 48.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W 6.0 0.340 0.300 90 90 Standard SGLASS2/Vinyl/Operable W CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4 Project Title.......... P1 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58 -----------------------------------------------------------------------------=- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ 22 Wind Left (E) 4.0 0.340 0.330 90 90 Standard EGLASS3/Vinyl/Fixed Wind 23 Wind Left (E) 10.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W 24 Wind Left (E) 20.0 0.340 0.330 90 90 Standard EGLASS5/Vinyl/Fixed Wind 25 Wind Left (E) 10.0 0.340 0.300 90 90 Standard EGLASS6/Vinyl/Operable W 26 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS7/Vinyl/Operable W 27 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS8/Vinyl/Operable W 28 Wind Left (E) 36.0 0.340 0.300 90 90 Standard EGLASS9/Vinyl/Operable W 29 Wind Left (SE) 12.0 0.340 0.330 135 90 Standard SEGLASSI/Vinyl/Fixed Win 30 Wind Back (SW) 12.0 0.340 0.330 225 90 Standard SWGLASSI/Vinyl/Fixed Win CASITA 9 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS9/Vinyl/Sliding G1 14 Wind Right (W) 6.0 0.340 0.300 270 90 Standard WGLASS5/Vinyl/Operable W 19 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS5/Vinyl/Operable W OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- ----- ----- ------ ----- ------ --------- --------- HOUSE 4 Window 36.0 6.00 6.00 10.0 0.25 n/a n/a 5 Door 48.0 6.00 8.00 10.0 0.25 n/a n/a 7 Door 48.0 6.00 8.00 10.0 0.25 n/a n/a 8 Window 36.0 6.00 6.00 10.0 0.25 n/a n/a 10 Window 48.0 6.00 8.00 10.0 0.25 n/a n/a 11 Window 48.0 6.00 8.00 10.0 0.25 n/a n/a 15 Window 6.0 1.00 6.00 6.00 0.25 n/a n/a 16 Window 6.0 1.00 6.00 6.00 0.25 n/a n/a 20 Window 48.0 6.00 8.00 10.0 0.25 n/a n/a 28 Window 36.0 6.00 6.00 4.00 0.25 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ HOUSE Standard Slab 2424 CASITA Standard Slab 255 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5 Project Title.......... Pl 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of . Minimum Refrig Charge Adequate Fan Watt Cooling Type ------------ Systems Efficiency EER or TXV Airflow Draw Capacity HOUSE ------- ----------- ----- ------------- -------- -------- -------- Furnace 1 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 1 14.00 SEER 11.6 Yes No No No CASITA HPSplit 1 7.70 HSPF n/a n/a n/a n/a n/a HPSplit 1 14.00 SEER 11.5 Yes No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) -------------------- (Btu/hr) (Btu/hr) ---------- HOUSE Furnace 49616 n/a n/a n/a ACSplit n/a 38625 47934 n/a CASITA HPSplit 8699 n/a n/a n/a HPSplit ------------- n/a 6411 7956 n/a Total ---------- 58315 -------------------- 45036 55890 ---------- n/a Orientation of Maximum..... Sizing Location............ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range ............... Front Facing 90 deg (E) LA QUINTA 26 F 70 F 111 F 75 F 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location ----------- R-value Leakage Area Ducts HOUSE -------------- -------- --------- Furnace Attic R-6 Yes No No ACSplit Attic R-6 Yes No No CASITA HPSplit Attic R-6 Yes No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 6 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Pl 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------- ----------------------- DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R-value Leakage Area Ducts ------------------------------------------------------- HPSplit Attic R-6 Yes No No WATER HEATING SYSTEMS --------------------- Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... P1 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION -------------------------- cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 8 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Pl 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER Name.... Kyle Tibbitts Company. Shea Homes/Trilogy Address. 60946 Desert Rose La Quinta, CA 92253 Phone... (760) 777-6026 License. 6Zz Signed.. 3^ y-of (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Chinh Nguyen Company. Westpac Air Conditioning, Inc. Address. 1610 N. Maple St. Corona, CA 92880 Phone... (951) 739-9501 Signed.. (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 1 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Pl 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I 1 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 I 1 (951) 739-9501 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM MF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or ZZ� equivalent U-factor in metal frame ceiling 150(b): Loose fill insulation manufacturer's labeled R-Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors / or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF-6R form _z 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 2 Project Title.......... P1 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58 ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM MF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed / SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Die En- sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the ` exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A T/ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation _1z *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 3 Project Title.......... Pl 6505/Opt.Bay 2/Casita Date..02/27/08 10:44:58 MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM MF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ---------------------------------------------------- 7-------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause / reductions in the cross -sectional area of the ducts 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with / mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause / degradation of the material 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no / electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating / b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot.< 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 4 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... P1 6505/Opt.Bay 2/Casita Date..02/27/08 ------------------------------------------------------------------------------- 10:44:58 ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6505CST Wth-CTZ15S05 Program -FORM MF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ----------------------------------------------------------------- and have an output frequency no less than 20 kHz 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high / efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air / tight (AT) to less than 2.0 CFM at 75 Pascals J 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply / with Section 119(d) / 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Seca 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) _Z SHEA HOMES PRODUCT-3 TRILOGY AT LA QUINTA PLAN -6420 Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 1 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. 1 1 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 1 1 (951) 739-9501 1 Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- ----------------------------------------------------------------- = MICROPAS7 ENERGY USE SUMMARY = = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) _--------------------------------- Design Design -------------------- Margin = - = Space Heating.......... 2.31 2.44 -0.13 = - Space Cooling 75.88 57.45 18.43 = = Water Heating.......... 10.32 9.54 0.78 = = North Total 88.51 69.43 19.08 = - Space Heating.......... 2.31 1.89 0.42 = - Space Cooling.......... 75.88 59.92 15.96 = = Water Heating.......... 10.32 9.54 0.78 = = East Total 88.51 71.35 17.16 = - Space Heating.......... 2.31 2.22 0.09 = - Space Cooling.......... 75.88 60.20 15.68 = = Water Heating.......... 10.32 9.54 0.78 = = South Total 88.51 71.96 16.55 = - Space Heating.......... 2.31 2.79 -0.48 = - Space Cooling 75.88 58.43 17.45 = = Water Heating.......... 10.32 9.54 0.78 = = West Total 88.51 70.76 17.75 = _ *** Building complies with Computer Performance _ ----------------------------------------------------------------- *** HERS Verification Required for Compliance CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43 MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 2477 sf Building Type.............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 24770 cf 2477 sf 24.2 % of floor area 0.34 Btu/hr-sf-F 0.31 10 ft BUILDING ZONE INFORMATION ---=--------------------- Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ----- ------------- ----- ------- ---------- Residence 2477 24770 1.00 4.0 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 1 Wall ----- Wood ---- 396 ----- 0.102 ----- 13 ----- 0 --- 180 ---- 90 --- Yes --------- IV.9 A3 -------------- SOUTH 2 Wall Wood 213 0.102 13 0 270 90 Yes IV.9 A3 WEST 3 Wall Wood 483 0.102 13 0 0 90 Yes IV.9 A3 NORTH 4 Wall Wood 468 0.102 13 0 90 90 Yes IV.9 A3 EAST 5 Wall Wood 36 0.102 13 0 315 90 Yes IV.9 A3 NORTHWEST 6 Wall Wood 582 0.102 13 0 0 .90 No IV.9 A3 GARAGE WALL 7 RoofRad Wood 2477 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 8 Door Wood 20 0.387 0 0 315 90 Yes None Wood Door 9 Door Wood 18 0.387 0 0 0 90 No None Wood Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- PERIMETER LOSSES ---------------- Appendix Length F2 Insul Solar IV Location/ .Surface (ft) Factor R-val Gains Reference Comments ------------ --------------------- -------------- ---------------------- 10 S1abEdge 215 0.900 R-0 No None To Outside 11•SlabEdge 60 0.550 R-0 No None TO GARAGE FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ 1 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASSI/Vinyl/Operable W 2 Wind Back (S) 30.0 0.340 0.300 180 90 Standard SGLASS2/Vinyl/Operable W 3 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS3/French Door 4 Door Right (W) 40.0 0.340 0.310 270 90 Standard WGLASSI/French Door 5 Wind Right (W) 2.3 0.340 0.330 270 90 Standard WGLASS2/Vinyl/Fixed Wind 6 Wind Right (W) 2.3 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind 7 Wind Right (W) 2.3 0.340 0.330 270 90 Standard WGLASS4/Vinyl/Fixed Wind 8 Wind Front (N) 24.0 0.340 0.300 0 90 Standard NGLASSI/Vinyl/Operable W 9 Wind Front (N) 24.0 0.340 0.300 0 90 Standard NGLASS2/Vinyl/Operable W 10 Door Front (N) 21.5 0.340 0.310 0 90 Standard NGLASS3/French Door 11 Wind Front (N) 6.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W 12 Wind Front (N) 40.0 0.340 0.300 0 90 Standard NGLASSS/Vinyl/Operable W 13 Wind Front (N) 10.0 0.340 0.330 0 90 Standard NGLASS6/Vinyl/Fixed Wind 14 Door Front (N) 24.0 0.340 0.310 0 90 Standard NGLASS7/French Door 15 Door Front (N) 48.0 0.340 0.310 0 90 Standard NGLASS8/Vinyl/Sliding G1 16 Wind Left (E) 20.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W 17 Wind Left (E) 12.0 0.340 0.300 90 90 Standard SGLASS2/Vinyl/Operable W 18 Door Left (E) 48.0 0.340 0.310 90 90 Standard SGLASS3/French Door 19 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W 20 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS5/Vinyl/Operable W 21 Door Left (E) 48.0 0.340 0.310 90 90 Standard EGLASS6/French Door. 22 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS7/Vinyl/Operable W 23 Wind Left (E) 24.0 0.340 0.300 90 90 Standard EGLASS8/Vinyl/Operable W 24 Wind Left (E) 24.0 0.340 0.300 90 90 Standard EGLASS9/Vinyl/Operable W 25 Wind Left (E) 20.0 0.340 0.300 90 90 Standard EGLASS10/Vinyl/Operable 26 Wind Right (NW) 9.0 0.340 0.330 315 90 Standard NWGLASSI/Vinyl/Fixed Win CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI 6420 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface ----------- (sf) ----- Width ----- Height ------ Depth ----- Height Extension --------------- Extension --------- 3 Door 48.0 6.00 8.00 10.0 0.50 n/a n/a 4 Door 40.0 5.00 8.00 3.00 0.50 n/a n/a 12 Window 40.0 5.00 8.00 7.00 0.50 n/a n/a 14 Door 24.0 3.00 8.00 8.00 0.50 n/a n/a 15 Door 48.0 6.00 8.00 8.00 0.50 n/a n/a 16 Window 20.0 5.00 4.00 8.00 1.00 n/a n/a 20 Window 12.0 2.00 6.00 8.00 1.00 n/a n/a 21 Door 48.0 6.00 8.00 8.00 1.00 n/a n/a 22 Window 12.0 2.00 6.00 8.00 1.00 n/a n/a 26 Window 9.0 1.50 6.00 6.00 1.00 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- Standard ------ Slab 2477 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type Systems Efficiency EER or TXV Airflow Draw Capacity ------------ Furnace ------- 1 ----------- 0.800 AFUE ----- ------------- -------- -------- n/a n/a n/a n/a -------- n/a ACSplit 1 14.00 SEER 11.5 Yes No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) (Btu/hr) (Btu/hr) ------------------------------ Furnace 49397 n/a n/a n/a ACSplit n/a 39589 49130 n/a Orientation of Maximum..... Front Facing 90 deg (E) CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43 ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R-value Leakage Area Ducts ------------------------------------------------------- Furnace Attic R-6 Yes No No ACSplit Attic R-6 Yes No No WATER HEATING SYSTEMS --------------------- Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 6 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI 6420 Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43 ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER Name.... Kyle Tibbitts Company. Shea Homes/Trilogy Address. 60946 Desert Rose La Quinta, CA 92253 Phone... (760) 777-6026 License. -76zx- = ".Vomlrdil ._ ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Chinh Nguyen Company. Westpac Air Conditioning, Inc. Address. 1610 N. Maple St. Corona, CA 92880 Phone... (951) 739-9501 Signed.. (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 1 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author.... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I I 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 1 I (951) 739-9501 1 Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM MF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling A-a8 150(b): Loose fill insulation manufacturer's labeled R-Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls)—�� *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed / 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.30, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF-6R form 116-17: Fenestration Products, Exterior Doors and Infiltration' Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 2 Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM MF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En- sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission / 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA �\ 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation / having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 1502A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B _ 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction �G piping includes a vapor retardant or is enclosed entirely / in conditioned space 7. Solar water -heating systems/collectors are certified by the , Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420 Standard Date..02/27/08 10:46:43 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM MF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used 2. Building.cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause / reductions in the cross -sectional area of the ducts 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material z 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch -� 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 4 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420 Standard Date..02/27/08 ------------------------------------------------------------------------------- 10:46:43 ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_6420 Wth-CTZ15S05 Program -FORM MF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ---------------------------------------------------------------------,----1------ and have an output frequency no less than 20 kHz 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130-(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to / comply with Section 119(d) SHEA HOMES PRODUCT-3 TRILOGY AT LA QUINTA PLAN-6420/OPT. BAY 2 Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1 ---------------------------------------=--------------------------------------- Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57 Project Address........ ******* --------------------- La Quinta, CA *.v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 I I (951) 739-9501 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- ---------------------------- ---------------------------- MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) ---------------------------------- Design Design -------------------- Margin = _ - Space Heating.......... 2.28 2.41 -0.13 = = Space Cooling.......... 75.55 56.98 18.57 = = Water Heating.......... 10.26 9.49 0.77 = = North Total 88.09 68.88 19.21 = = Space Heating..... ... 2.28 1.87 0.41 = = Space Cooling.......... 75.55 59.42 16.13 = = Water _ Heating.......... 10.26 9.49 0.77 = - = East Total -------- 88.09 ---------------- 70.78 17.31 = - Space Heating.......... 2.28 2.19 0.09 = - Space Cooling.......... 75.55 59.69 15.86 = = Water _ Heating.......... 10.26 9.49 0.77 = - = South Total -------- 88.09 ---------------- 71.37 16.72 = - Space Heating.......... 2.28 2.74 -0.46 = - Space Cooling.......... 75.55 57.95 17.60 = = Water _ Heating.......... 10.26 9.49 0.77 = - = West Total -------- 88.09 ---------------- 70.18 17.91 = _ *** Building complies with Computer Performance _ *** HERS Verification Required for Compliance *** _ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57 ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 2503 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 25030 cf 2503 sf 23.9 % of floor area 0.34 Btu/hr-sf-F 0.31 10 ft BUILDING ZONE INFORMATION Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ----- ------------- ----- ------- ---------- Residence 2503 25030 1.00 4.0 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 1 Wall ----- Wood ---- 396 ----- 0.102 ----- 13 ----- 0 --- 180 ---- 90 --- Yes --------- IV.9 A3 -------------- SOUTH 2 Wall Wood 213 0.102 13 0 270 90 Yes IV.9 A3 WEST 3 Wall Wood 483 0.102 13 0 0 90 Yes IV.9 A3 NORTH 4 Wall Wood 468 0.102 13 0 90 90 Yes IV.9 A3 EAST 5 Wall Wood 36 0.102 13 0 315 90 Yes IV.9 A3 NORTHWEST 6 Wall Wood 582 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 7 RoofRad Wood 2477 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 8 Door Wood 20 0.387 0 0 315 90 Yes None Wood Door 9 Door Wood 18 0.387 0 0 0 90 No None Wood Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3 Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57 ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- PERIMETER LOSSES Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ --------------------- -------------- ---------------------- 10 S1abEdge 215 0.900 R-0 No None To Outside 11 SlabEdge 60 0.550 R-0 No None TO GARAGE FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ --.--- ----- ----- --- ------------ ------------------------ 1 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASSI/Vinyl/Operable W 2 Wind Back (S) 30.0 0.340 0.300 180 90 Standard SGLASS2/Vinyl/Operable W 3 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS3/French Door 4 Door Right (W) 40.0 0.340 0.310 270 90 Standard WGLASSI/French Door 5 Wind Right (W) 2.3 0.340 0.330 270 90 Standard WGLASS2/Vinyl/Fixed Wind 6 Wind Right (W) 2.3 0.340 0.330 270 90 Standard WGLASS3/Vinyl/Fixed Wind 7 Wind Right (W) 2.3 0.340 0.330 270 90 Standard WGLASS4/Vinyl/Fixed Wind 8 Wind Front (N) 24.0 0.340 0.300 0 90 Standard NGLASSI/Vinyl/Operable W 9 Wind Front (N) 24.0 0.340 0.300 0 90 Standard NGLASS2/Vinyl/Operable W 10 Door Front (N) 21.5 0.340 0.310 0 90 Standard NGLASS3/French Door 11 Wind Front (N) 6.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W 12 Wind Front (N) 40.0 0.340 0.300 0 90 Standard NGLASS5/Vinyl/Operable W 13 Wind Front (N) 10.0 0.340 0.330 0 90 Standard NGLASS6/Vinyl/Fixed Wind 14 Door Front (N) 24.0 0.340 0.310 0 90 Standard NGLASS7/French Door 15 Door Front (N) 48.0 0.340 0.310 0 90 Standard NGLASS8/Vinyl/Sliding G1 16 Wind Left (E) 20.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W 17 Wind Left (E) 12.0 0.340 0.300 90 90 Standard SGLASS2/Vinyl/Operable W 18 Door Left (E) 48.0 0.340 0.310 90 90 Standard SGLASS3/French Door 19 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS4/Vinyl/Operable W 20 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASSS/Vinyl/Operable W 21 Door Left (E) 48.0 0.340 0.310 90 90 Standard EGLASS6/French Door 22 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS7/Vinyl/Operable W 23 Wind Left (E) 24.0 0.340 0.300 90 90 Standard EGLASS8/Vinyl/Operable W 24 Wind Left (E) 24.0 0.340 0.300 90 90 Standard EGLASS9/Vinyl/Operable W 25 Wind Left (E) 20.0 0.340 0.300 90 90 Standard EGLASS10/Vinyl/Operable 26 Wind Right (NW) 9.0 0.340 0.330 315 90 Standard NWGLASSI/Vinyl/Fixed Win CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57 MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 ------------------------------------------------------------------------------- OVERHANGS Window--- ------------ Overhang ------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- 3 Door ----- 48.0 ----- 6.00 ------ 8.00 ----- 10.0 --------------- 0.50 n/a --------- n/a 4 Door 40.0 5.00 8.00 3.00 0.50 n/a n/a 12 Window 40.0 5.00 8.00 7.00 0.50 n/a n/a 14 Door 24.0 3.00 8.00 8.00 0.50 n/a n/a 15 Door 48.0 6.00 8.00 8.00 0.50 n/a n/a 16 Window 20.0 5.00 4.00 8.00 1.00 n/a n/a 20 Window 12.0 2.00 6.00 8.00 1.00 n/a n/a 21 Door 48.0 6.00 8.00 8.00 1.00 n/a n/a 22 Window 12.0 2.00 6.00 8.00 1.00 n/a n/a 26 Window 9.0 1.50 6.00 6.00 1.00 n/a n/a SLAB SURFACES ------------- Area Slab Type ---------------- (sf) ------ Standard Slab 2503 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type ------------ Systems ------- Efficiency EER or TXV Airflow Draw Capacity Furnace 1 ----------- 0.800 AFUE ----- ------------- n/a n/a -------- -------- n/a n/a -------- n/a ACSplit 1 14.00 SEER 11.5 Yes No No No HVAC SIZING e Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) -------------------- (Btu/hr) (Btu/hr) Furnace 49510 n/a ---------- n/a n/a ACSplit n/a 39656 49213 n/a Orientation of Maximum..... Front Facing 90 deg (E) CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57 ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM CF-1R I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R-value Leakage Area Ducts ------------------------------------------------------- Furnace Attic R-6 Yes No No ACSplit Attic R-6 Yes No No WATER HEATING SYSTEMS --------------------- Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6 Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER Name.... Kyle Tibbitts Company. Shea Homes/Trilogy Address. 60946 Desert Rose La Quinta, CA 92253 Phone... (760) 777-6026 License. qo 77 5?5 Signed.. 16'e // - 3 -1-0 (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed. (date) Name... Company Address Phone... Signed.. DOCUMENTATION AUTHOR Chinh Nguyen Westpac Air Conditioning, Inc. 1610 N. Maple St. Corona, CA 92880 (951) 739-9501 - v% (date) 0 MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 1 ------------------------------------------------------------------------------- Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57 Project Address........ ******* --------------------- Documentation Author.. Climate Zone.......... La Quinta, CA Chinh Nguyen Westpac Air Conditioning, 1610 N. Maple St. Corona, CA 92880 (951) 739-9501 15 *v7.10* 1 I ******* I Building Permit # I Inc. I I I Plan Check / Date I I I I Field Check/ Date I --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM MF-lR j I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents,or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling 150(b): Loose fill insulation manufacturer's labeled R-Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply / to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual / 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.30, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF-6R form 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 2 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57 MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM MF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En- sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance / with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater / 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or 7— brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to / Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, 7 MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 3 Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 10:48:57 MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM MF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used / 2. Building cavities, support platforms for air handlers, and T plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating / b. Cover for outdoor pools or outdoor spas. J 3. Pool system has directional inlets and a circulation pump time switch 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Page 4 Project Title.......... Plan 6420/Option Bay 2 Date..02/27/08 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 10:48:57 MICROPAS7 v7.10 File-T6420OB2 Wth-CTZ15S05 Program -FORM MF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 ------------------------------------------------------------------ and have an output frequency no less than 20 kHz 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically / or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall / have lighting that complies with Sec. 130, 131, and 146 t/ 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR j are controlled by an occupant sensor(s) certified to comply with Section 119(d) SHEA HOMES PRODUCT-3 TRILOGY AT LA QUINTA PLAN-6420/OPT. BAY 21CASITA Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 1 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. 1 1610 N. Maple St. Plan Check / Date I Corona, CA 92880 1 (951) 739-9501 1 Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- ---------------------------- ---------------------------- MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) ---------------------------------- Design Design -------------------- Margin = - = Space Heating.......... 2.57 2.86 -0.29 = - Space Cooling.......... 77.36 60.08 17.28 = = Water _ Heating.......... 9.31 -------- 8.61 0.70 = - = North Total 89.24 ---------------- 71.55 17.69 = - Space Heating.......... 2.57 2.38 0.19 = - Space Cooling.......... 77.36 62.95 14.41 = = Water _ Heating.......... 9.31 8.61 0.70 = - = East Total -------- 89.24 ---------------- 73.94 15.30 = - Space Heating.......... 2.57 2.69 -0.12 = = Space Cooling.......... 77.36 62.15 15.21 = = Water _ Heating.......... 9.31 8.61 0.70 = - = South Total -------- 89.24 ---------------- 73.45 15.79 = = Space Heating.......... 2.57 3.16 -0.59 = - Space Cooling.......... 77.36 61.37 15.99 = = Water _ Heating.......... 9.31 8.61 0.70 = - = West Total -------- 89.24 ---------------- 73.14 16.10 = _ *** Building complies with Computer Performance _ ----------------------------------------------------------------- ----------------------------------------------------------------- *** HERS Verification Required for Compliance CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 2758 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 2 27580 cf 2758 sf 24.3 % of floor area 0.34 Btu/hr-sf-F 0.31 10 ft BUILDING ZONE INFORMATION Floor ------------------------- # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type -------------- (sf) ----- (cf) ------ Units ----- le ----- ioned ----- Type -------- (ft) ----- (sf) ------- Housewrap ---------- HOUSE Residence 2503 25030 0.80 3.2 Yes Setback 2.0 Standard No CASITA Residence 255 2550 0.20 0.8 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface ------------ Type (sf) or R-val R-val Azm Tilt Reference Comments HOUSE ----- ---- ----- ----- ----- --- ---- --- --------- -------------- 1 Wall Wood 396 0.102 13 0 180 90 Yes IV.9 A3 SOUTH 3 Wall Wood 213 0.102 13 0 270 90 Yes IV.9 A3 WEST 5 Wall Wood 483 0.102 13 0 0 90 Yes IV.9 A3 NORTH 7 Wall Wood 468 0.102 13 0 90 90 Yes IV.9 A3 EAST 9 Wall Wood 36 0.102 13 0 315 90 Yes IV.9 A3 NORTHWEST 10 Wall Wood 582 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 11 RoofRad Wood 2477 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 13 Door Wood 20 0.387 0 0 315 90 Yes None Wood Door 14 Door Wood 18 0.387 0 0 0 90 No None Wood Door CASITA CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3 Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46 MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ ----- ---- ----- ----- ----- --- ---- -------------------------- 2 Wall Wood 122 0.102 13 0 180 90 Yes IV.9 A3 SOUTH 4 Wall Wood 139 0.102 13 0 270 90 Yes IV.9 A3 WEST 6 Wall Wood 152 0.102 13 0 0 90 Yes IV.9 A3 NORTH 8 Wall Wood 145 0.102 13 0 90 90 Yes IV.9 A3 EAST 12 RoofRad Wood 255 0.025 38 0 n/a 0 Yes IV.1 A18 Attic PERIMETER LOSSES ---------------- Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ --------------------- -------------- ---------------------- HOUSE 15 SlabEdge 215 0.900 R-0 No None To Outside 17 SlabEdge 60 0.550 R-0 No None TO GARAGE .CASITA 16 SlabEdge 63 0.900 R-0 No None To Outside FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ --=-- ----- ----- --- ------------ ------------------------ unrlc V 1 Wind Back (S) 36.0 0.340 0.300 180 90 2 Wind Back (S) 30.0 0.340 0.300 180 90 3 Door Back (S) 48.0 0.340 0.310 180 90 5 Door Right (W) 40.0 0.340 0.310 270 90 6 Wind Right (W) 2.3 0.340 0.330 270 90 7 Wind Right (W) 2.3 0.340 0.330 270 90 8 Wind Right (W) 2.3 0.340 0.330 270 90 10 Wind Front (N) 24.0 0.340 0.300 0 90 11 Wind Front (N) 24.0 0.340 0.300 0 90 12 Door Front (N) 21.5 0.340 0.310 0 90 13 Wind Front (N) 6.0 0.340 0.300 0 90 14 Wind Front (N) 40.0 0.340 0.300 0 90 15 Wind Front (N) 10.0 0.340 0.330 0 90 16 Door Front (N) 24.0 0.340 0.310 0 90 17 Door Front (N) 48.0 0.340 0.310 0 90 19 Wind Left (E) 20.0 0.340 0.300 90 90 20 Wind Left (E) 12.0 0.340 0.300 90 90 21 Door Left (E) 48.0 0.340 0.310 90 90 22 Wind Left (E) 12.0 0.340 0.300 90 90 Standard SGLASSI/Vinyl/Operable W Standard SGLASS2/Vinyl/Operable W Standard SGLASS3/French Door Standard WGLASSI/French Door Standard WGLASS2/Vinyl/Fixed Wind Standard WGLASS3/Vinyl/Fixed Wind Standard WGLASS4/Vinyl/Fixed Wind Standard NGLASSI/Vinyl/Operable W Standard NGLASS2/Vinyl/Operable W Standard NGLASS3/French Door Standard NGLASS4/Vinyl/Operable W Standard NGLASSS/Vinyl/Operable W Standard NGLASS6/Vinyl/Fixed Wind Standard NGLASS7/French Door Standard NGLASS8/Vinyl/Sliding G1 Standard EGLASSI/Vinyl/Operable W Standard SGLASS2/Vinyl/Operable W Standard SGLASS3/French Door Standard EGLASS4/Vinyl/Operable W CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 4 Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46 I MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ 23 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASSS/Vinyl/Operable W 24 Wind Left (E) 48.0 0.340 0.330 90 90 Standard EGLASS6/Vinyl/Fixed Wind 25 Wind Left (E) 12.0 0.340 0.300 90 90 Standard EGLASS7/Vinyl/Operable W 26 Wind Left (E) 24.0 0.340 0.300 90 90 Standard EGLASS8/Vinyl/Operable W 27 Wind Left (E) 24.0 0.340 0.300 90 90 Standard EGLASS9/Vinyl/Operable W 28 Wind Left (E) 20.0 0.340 0.300 90 90 Standard EGLASS10/Vinyl/Operable 29 Wind Right (NW) 9.0 0.340 0.330 315 90 Standard NWGLASSI/Vinyl/Fixed Win CASITA 4 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS4/Vinyl/Sliding Gl 9 Wind Right (W) 6.0 0.340 0.300 270 90 Standard WGLASSS/Vinyl/Operable W 18 Wind Front (N) 18.0 0.340 0.300 0 90 Standard NGLASS9/Vinyl/Operable W OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- ----- ----- ------ ----- ------ --------- --------- HOUSE 1 Window 36.0 6.00 6.00 1.00 0.50 n/a n/a 2 Window 30.0 6.00 5.00 1.00 0.50 n/a n/a 3 Door 48.0 6.00 8.00 10.0 0.50 n/a n/a 5 Door 40.0 5.00 8.00 3.00 0.50 n/a n/a 14 Window 40.0 5.00 8.00 7.00 0.50 n/a n/a 16 Door 24.0 3.00 8.00 8.00 0.50 n/a n/a 17 Door 48.0 6.00 8.00 8.00 0.50 n/a n/a 19 Window 20.0 5.00 4.00 8.00 1.00 n/a n/a 23 Window 12.0 2.00 6.00 8.00 1.00 n/a n/a 24 Window 48.0 6.00 8.00 8.00 1.00 n/a n/a 25 Window 12.0 2.00 6.00 8.00 1.00 n/a n/a 29 Window 9.0 1.50 6.00 6.00 1.00 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) HOUSE Standard Slab 2503 CASITA Standard Slab 255 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5 Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46 ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type ------------ Systems ------- Efficiency ----------- EER or TXV Airflow Draw Capacity HOUSE ----- ------------- -------- -------- -------- Furnace 1 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 1 14.00 SEER 11.5 Yes No No No CASITA HPSplit 1 7.70 HSPF n/a n/a n/a n/a n/a HPSplit 1 14.00 SEER 11.5 Yes No No No HVAC SIZING Verified Total Sensible Design .Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr) ----------------------------------------------------- HOUSE Furnace 49510 n/a n/a n/a ACSplit n/a 39032 48439 n/a CASITA HPSplit 8699 n/a n/a n/a HPSplit n/a 6411 7956 n/a ----------------------------------------------------- Total 58209 45444 56395 n/a Orientation of Maximum..... Front Facing 90 deg (E) Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R-value Leakage Area Ducts ------------------------------------------------------- HOUSE Furnace Attic R-6 Yes No No ACSplit Attic R-6 Yes No No CASITA HPSplit Attic R-6 Yes No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6 Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46 MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R-value Leakage Area Ducts ------------------------------------------------------- HPSplit Attic R-6 Yes No No WATER HEATING SYSTEMS --------------------- Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- - ------------ ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 7 ------------------------------------------------------------------------------- Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46 I MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION -------------------------- cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 8 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER Name.... Kyle Tibbitts Company. Shea Homes/Trilogy Address. 60946 Desert Rose La Quinta, CA 92253 Phone... (760) 777-6026 License. 6 Signed.. 7j-y-O p (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed. (date) DOCUMENTATION AUTHOR Name.... Chinh Nguyen Company. Westpac Air Conditioning, Inc. Address. 1610 N. Maple St. Corona, CA 92880 Phone... (951)n739-9501 Signed.. (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 1 Project Title.......... Plan 6420/OptBay2/Casita. Date..02/27/08 10:50:46 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I 1 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 I 1 (951) 739-9501 I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. I MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM MF-1R I User#-MP2387 User-Westpac ------------------------------------------------------------------------------- Air Conditioning, Run -Trilogy at La Quinta P-3 I Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling — 150(b): Loose fill insulation manufacturer's labeled R-Value *150(c): Minimum R-13 wall insulation in wood framed walls or _ equivalent U-factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors �. or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox b. Outside air intake with damper and control, flue _ damper and control 2. No continuous burning gas pilot lights allowed _ 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF-6R form 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 2 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM MF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En- sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind . 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to .meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 3 Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46 ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM MF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic / and either mesh or tape shall be used 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with / mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater we th r r f t' t t' , a e p o0 opera ing ins ruc ions, -- electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating / b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 4 Project Title.......... Plan 6420/OptBay2/Casita Date..02/27/08 10:50:46 MICROPAS7 v7.10 File-T6420CST Wth-CTZ15S05 Program -FORM MF-lR I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ----------------- =------------------------------------------------------------- and have an output frequency no less than 20 kHz 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that / does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air j tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR ; are controlled by an occupant sensor(s) certified to comply with Section 119(d) SHEA HOMES PRODUCT-3 TRILOGY AT LA QUINTA PLAN -643 0 Chinh Nguyen, Certified Energy Analyst ♦ (951) 739-9501 / (951) 739-9509 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- CF-lR Page 1 Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02 Project Address........ ******* --------------------- La Quinta, CA *v7.10* I I Documentation Author... Chinh Nguyen ******* I Building Permit # I Westpac Air Conditioning, Inc. I 1 1610 N. Maple St. I Plan Check / Date I Corona, CA 92880 I 1 (951) 739-9501 I Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method...... ------------------------------------------------------------------------------- MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy ------------------------------------------------------------------------------- at La Quinta .P-3 I ---------------------------- ---------------------------- MICROPAS7 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kTDV/sf-yr) ------------------------ ---------- Design Design -------------------- Margin = = Space Heating 2.30 1.88 0.42 = = Space Cooling.......... 74.93 56.14 18.79 = = Water.Heating.......... 9.28 8.57 0.71 = = North Total 86.51 66.59 19.92 = = Space Heating.......... 2.30 2.37 -0.07 = = Space Cooling.......... 74.93 58.78 16.15 = = Water Heating.......... 9.28 8.57 0.71 = = East Total 86.51 69.72 16.79 = - Space Heating.......... 2.30 2.76 -0.46 = - Space Cooling 74.93 54.58 20.35 = = Water Heating.......... 9.28 8.57 0.71 = = South Total 86.51 65.91 20.60 = - Space Heating.......... 2.30 2.26 0.04 = - Space Cooling.......... 74.93 57.07 17.86 = = Water _ Heating.......... 9.28 8.57 0.71 = = West Total -------- 86.51 ---------------- 67.90 - 18.61 = _ *** Building complies with Computer Performance _ *** HERS Verification Required for Compliance *** _ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02 I MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM CF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 2769 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type ................. NaturalGas Building Front Orientation. Cardinal - N,E.,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 27690 cf 2769 sf 22.1 % of floor area 0.34 Btu/hr-sf-F 0.31 10 ft BUILDING ZONE INFORMATION ------------------------- Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ----- ------------- ----- ------- ---------- Residence 2769 27690 1.00 4.0 Yes Setback 2.0 Standard No OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 1 Wall ----- Wood ---- 406 ----- 0.102 ----- 13 ----- 0 --- 180 ---- 90 --- Yes --------- IV.9 A3 -------------- SOUTH 2 Wall Wood 512 0.102 13 0 270 90 Yes IV.9 A3 WEST 3 Wall Wood 320 0.102 13 0 0 90 Yes IV.9 A3 NORTH 4 Wall Wood 614 0.102 13 0 90 90 Yes IV.9 A3 EAST 5 Wall Wood 18 0.102 13 0 135 90 Yes IV.9 A3 SOUTHEAST 6 Wall Wood 18 0.102 13 0 225 90 Yes IV.9 A3 SOUTHWEST 7 Wall Wood 532 0.102 13 0 0 90 No IV.9 A3 GARAGE WALL 8 RoofRad Wood 2769 0.025 38 0 n/a 0 Yes IV.1 A18 Attic 9 Door Wood 20 0.387 0 0 0 90 Yes None Wood Door 10 Door Wood 18 0.387 0 0 0 90 No None Wood Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02 -----------------------------=------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM CF-lR I I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- PERIMETER LOSSES ---------------- Appendix Length F2 Insul Solar IV Location/ Surface (ft) Factor R-val Gains Reference Comments ------------ 11 SlabEdge ------ 252 -------- 0.900 ------- R-0 ----- No --------- None ---------------------- To Outside 12 SlabEdge 55 0.550 R-0 No None TO GARAGE FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ 1 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASSI/Vinyl/Operable W 2 Wind Back (S) 36.0 0.340 0.330 180 90 Standard SGLASS2/Vinyl/Fixed Wind 3 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS3/Vinyl/Operable W 4 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASS4/Vinyl/Sliding G1 5 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS5/Vinyl/Operable W 6 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS6/Vinyl/Operable W 7 Door Back (S) 48.0 0.340 0.310 180 90 Standard SGLASSI/French Door 8 Wind Back (S) 36.0 0.340 0.300 180 90 Standard SGLASS8/Vinyl/Operable W 9 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASS9/Vinyl/Operable W 10 Wind Back (S) 36.0 0.340 0.330 180 90 Standard SGLASS10/Vinyl/Fixed Win 11 Wind Back (S) 12.0 0.340 0.300 180 90 Standard SGLASSII/Vinyl/Operable 12 Wind Right (W) 12.0 0.340 0.300 270 90 Standard WGLASSI/Vinyl/Operable W 13 Wind Right (W) 12.0 0.340 0.300 270 90 Standard WGLASS2/Vinyl/Operable W 14 Wind Right (W) 4.0 0.340 0.300 270 90 Standard WGLASS3/Vinyl/Operable W 15 Wind Right (W) 20.0 0.340 0.300 270 90 Standard WGLASS4/Vinyl/Operable W 16 Wind Front (N) 24.0 0.340 0.300 0 90 Standard NGLASSI/Vinyl/Operable W 17 Wind Front (N) 6.0 0.340 0.330 0 90 Standard NGLASS2/Vinyl/Fixed Wind 18 Wind Front (N) 15.0 0.340 0.300 0 90 Standard NGLASS3/Vinyl/Operable W 19 Wind Front (N) 15.0 0.340 0.300 0 90 Standard NGLASS4/Vinyl/Operable W 20 Wind Front (N) 12.0 0.340 0.300 0 90 Standard NGLASS5/Vinyl/Operable W 21 Wind Front (N) 36.0 0.340 0.330 0 90 Standard NGLASS6/Vinyl/Fixed Wind 22 Wind Front (N) 12.0 0.340 0.300 0 .90 Standard NGLASSI/Vinyl/Operable W 23 Wind Left (E) 18.0 0.340 0.300 90 90 Standard EGLASSI/Vinyl/Operable W 24 Wind Left (E) 18.0 0.340 0.300 90 90 Standard SGLASS2/Vinyl/Operable W 25 Wind Left (E) 4.0 0.340 0.300 90 90 Standard EGLASS3/Vinyl/Operable W 26 Wind Left (E) 8.0 0.340 0.300 90 90 Standard SGLASS4/Vinyl/Operable W 27 Door Left (E) 48.0 0.340 0.310 90 90 Standard EGLASS5/Vinyl/Sliding Gl 28 Wind Left (SE) 12.0 0.340 0.330 135 90 Standard SEGLASSI/Vinyl/Fixed Win 29 Wind Back (SW) 12.0 0.340 0.330 225 90 Standard SWGLASSI/Vinyl/Fixed Win CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4 Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02 ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- OVERHANGS ---Window--- ------------ Overhang ------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- 4 Door ----- 48.0 ----- 6.00 ------ 8.00 ----- 5.00 ------ 0.50 ------------------ n/a n/a 5 Window 36.0 6.00 6.00 6.00 0.50 n/a n/a 6 Window 36.0 6.00 6.00 6.00 0.50 n/a n/a 9 Window 12.0 2.00 6.00 8.00 0.50 n/a n/a 10 Window 36.0 6.00 6.00 8.00 0.50 n/a n/a 11 Window 12.0 2.00 6.00 8.00 0.50 n/a n/a 17 Window 6.0 1.00 6.00 5.00 0.50 n/a n/a 20 Window 12.0 2.00 6.00 8.00 0.50 n/a n/a 21 Window 36.0 6.00 6.00 8.00 0.50 n/a n/a 22 Window 12.0 2.00 6.00 8.00 0.50 n/a n/a 23 Window 18.0 3.00 6.00 6.00 1.00 n/a n/a 27 Door 48.0 6.00 8.00 10.0 1.00 n/a n/a 28 Window 12.0 2.00 6.00 5.00 1.00 n/a n/a 29 Window 12.0 2.00 6.00 5.00 1.00 n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ Standard Slab 2769 HVAC SYSTEMS ------------ Verified Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type ------------ Systems Efficiency EER or TXV Airflow Draw Capacity Furnace ------- 1 ----------- ----- 0.800 AFUE n/a ------------- n/a -------- n/a -------- n/a -------- n/a ACSplit 1 14.00 SEER 11.5 Yes No No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02 ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- Furnace 54249 n/a n/a n/a ACSplit n/a 42766 53072 n/a Orientation of Maximum..... Sizing Location............ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range. ............ Front Facing 90 deg (E) LA QUINTA 26 F 70 F 111 F 75 F 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R-value Leakage Area Ducts ------------------------------------------------------- Furnace Attic R-6 Yes No No ACSplit Attic R-6 Yes No No WATER HEATING SYSTEMS --------------------- Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R-value ------------------------------------------- -------------- ---------------- 1 Storage Gas Standard 1 0.62 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02 -----------------------------=------------------=------------------------------ ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM CF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This is a multiple orientation building. This printout is for the front facing North. This building incorporates a Radiant Barrier. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified Insulation Installation. This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 7 Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM CF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER Name.... Kyle Tibbitts Company. Shea Homes/Trilogy Address. 81-260 Avenue 62 La Quinta, CA 92253 Phone... (760) 777-6026 License. �ZZQ Signed.. f [� (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Chinh Nguyen Company. Westpac Air Conditioning, Inc. Address. 1610 N. Maple St. Corona, CA 92880 Phone... (951) 739-9501 Signed.. 17— (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 1 ------------------------------------------------------------------------------- Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02 Project Address........ ******* --------------------- La Quinta, CA *v7.10* Documentation Author... Chinh Nguyen ******* Westpac Air Conditioning, Inc. 1610 N. Maple St. Corona, CA 92880 (951) 739-9501 Building Permit # Plan Check / Date Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, .Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM MF-lR User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 I ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U-factor in metal frame ceiling //3a 150(b): Loose fill insulation manufacturer's labeled R-Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U-factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.30, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type -and include CF-6R form 116-17: Fenestration Products, Exterior Doors and Infiltration Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 2 Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02 ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM MF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 ------------------------------------------------------------------------------- label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En- sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA / 150(i): Setback thermostat on all applicable heating and/or / cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation / having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R-value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water / pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to / Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A .5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space 7. Solar water -heating systems/collectors are certified by t Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601., 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-lR Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM MF-1R User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 ------------- ----------------------------------------------------------------- UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to reductions in the cross -sectional area of the ducts _ 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands _ 4. Exhaust fan systems have back draft or automatic dampers_ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers _ 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protectec as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material _ 7. Flexible ducts cannot have porous inner cores _ 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the heater weather - roof o eratin instructions no P electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating / b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch 115: Gas -fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES n/a 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic De- En- sign- force er ment MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Page 4 Project Title.......... Plan 6430 Standard Date..02/27/08 10:52:02- ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-TRI_6430 Wth-CTZ15S05 Program -FORM MF-1R I User#-MP2387 User-Westpac Air Conditioning, Run -Trilogy at La Quinta P-3 ------------------------------------------------------------------------------- and have an output frequency no less than 20 kHz 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply j with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d)