MA 2020-0007 77138 Casa Del Sol (10.14.2020)
October 14, 2020
Daniel Paris
Paris Construction
240 Paseo Vista Circle
Palm Desert, CA 92260
SUBJECT: MINOR ADJUSTMENT 2020-0007 – 77-138 Casa Del Sol
Dear Mr. Paris:
The Design and Development Department has reviewed your Minor Adjustment
application (MA 2020-0007), pursuant to Section 9.210.040 of the City of La Quinta
Zoning Code.
REQUEST:
Grants up to a 10% adjustment to increase the maximum height of a structure from
17’ to 18’-8” to provide architectural enhancement. This request is to increase the
maximum height of the structure to be 17’ – 11” for architectural enhancement, per
the attached exhibit. The architectural projections section of our municipal code
9.50.060 allows for architectural projections to be three (3) feet above the
maximum allowed height, which allows the chimney height to be at proposed height
of 21’ – 6”.
DECISION:
Approval is granted for the requested adjustment based on the following findings
and subject to the conditions of approval listed below:
1. Minor Adjustment 2020-0007 is consistent with the La Quinta General Plan, in
that the proposal does not alter the approved land use for the property or
affect land use on surrounding similar properties.
2. Minor Adjustment 2020-0007 is consistent with the intent of the La Quinta
Zoning Code in that the requested adjustments will be conditioned to comply
with all other development standards as required under the Zoning Code.
3. Processing and approval of Minor Adjustment 2020-0007 is in compliance with
the California Environmental Quality Act. The adjustment requested falls
under CEQA Guidelines Section 15305(a) as a “Minor Alterations to Land” -
Class 5 Categorical Exemption.
4. Approval of Minor Adjustment 2020-0007 is not detrimental to the public
health, safety and general welfare, nor injurious or incompatible with other
properties and land use in the vicinity. The adjustment has no impact on
health or safety issues and will not affect physical land use characteristics in
the vicinity. The adjustment will be compatible with the architectural styles
of the existing surrounding single-family homes.
CONDITIONS OF APPROVAL:
1. A building permit shall be obtained prior to construction. The proposed
construction shall comply with all other development standards as required
under the La Quinta Zoning Code.
2. No more than two (2) additional minor adjustments shall be approved for this
lot.
Please be advised that the City only approves three Minor Adjustments per lot,
regardless of the percentage of the development standard adjusted. This approval
consists of one Minor Adjustments and only two additional Minor Adjustments are
available to be approved for this lot. This approval relates only to the minor
adjustments referenced herein and does not imply any entitlement or approval of a
building permit for any structures shown on the plans on file. All other development
standards of the La Quinta Zoning Code are applicable and shall be adhered to in
preparing plans for building plan check. If you have any additional questions, please
contact me at 760-777-7086.
Sincerely,
Sijifredo Fernandez
Associate Planner
Attachment: 1) Elevations
A RESIDENCE FOR:JASON P. & DEBRA A. DECKER77138 CASA DEL SOLLA QUINTA, CA 92253Project:
A RESIDENCE FOR:FORJASON P. & DEBRA A. DECKER
7/27/20
Issue Date
6.0EXTERIORELEVATIONSWALLING & McCALLUM LIMITEDHereby reserves its common lawcopyright in these drawings andspecifications. They are not to becopied or assigned to any third partynot are they to be used on any otherproject or building site without thewritten permission of WALLING &McCALLUM LIMITED.WALLING & McCALLUM LIMITEDARCHITECTURE ENGINEERING PLANNING77218 Casa Del Sol- La Quinta, CA 92253 - PH\(760)360 0250 FX\(760)360 0786REVISIONS NRO--NOLL
D
HJ MIGANW
No. C 7424
ALLINGREN.FILCFOEATTSIAA218220
A R TIECH
E
CTICE NSL 1
FILE INFORMATION: Archicad:Decker Residence:Floor Plan.pln | 6.0:EXTERIOR ELEVATIONS | 7/27/20 | 8:41 AMPlan Check 7.24.20
ELEVATION GENERAL NOTES
A. REFER TO FLOOR PLANS FOR DIMENSION NOT SHOWN.
B. REFER TO STRUCTURAL PLANS FOR SIZES & DETAILS OF ALL
STRUCTURAL MEMBERS AND DIAPHRAMS.
C. REFER FOUNDATION PLAN FOR SIZES AND DETAILS OF ALL FOOTINGS.
D. REFER TO WINDOW & DOOR SCHEDULES FOR MORE INFORMATION.
E. ALL GLAZING IN HAZARDOUS LOCATIONS AS DEFINED IN 2007 CBC 2406.1
SHALL BE TEMPERED GLASS.- SEE NOTES SHEET5.0 .
a. TG = TEMPERED GLASS. | LAM = LAMINATE GLASS.
F. EXTERIOR FINISH SHALL BE 3-COAT; 7/8" PLASTER
a. CUSTOM COLOR PER EXTERIOR MATERIALS LEGEND, THIS SHEET
b. SHEET 10 GENERAL NOTES FOR APPLICATION REQUIREMENTS.
c. CONVENTIONAL 7/8" STUCCO OVER DUPONT TYVEK STUCCO WRAP
(ESR-2375)
d. SCRATCH AND BROWN COATS TO INCORPORATE CHOPPED FIBERS
G. PROVIDE MTL SPARK ARRESTORS AS SHOWN 24" ABOVE THE TALLEST
ROOF WITHIN 10'-0" OF THE CHIMNEY.
H. ALL HEIGHTS SHOWN ARE TO T.o.FRAMING FROM T.o.SLAB (+0'-0")
a. TOP OF SLAB(0'-0") IS 6" ABOVE APPROVED GRADE
I ALL EXTERIOR OPENINGS SHALL BE FLASHED AND COUNTER FLASHED.
WEATHERSTRIP ALL EXTERIOR DOORS PER CBC 1402
J GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO INSURE A
WATERTIGHT SEAL AT ALL EXTERIOR FINISHES
K.
ELEVATION REFERENCE NOTES
1. PLASTER FINISH [TYP.]
a. “MACHINE DASH” FINISH
b. SQUARED CORNERS [TYP.]
c. PROVIDE A WEEP SCREED [26ga MIN.] AT ALL EXTERIOR PLASTER TO
FOUNDATION CONNECTIONS. WEEP SCREED AT FOUNATION LINE
d. ELASTOMERIC PAINT
e. SEE GENERAL NOTES ABOVE FOR MORE FINISH AND INSTALLATION
INFORMATION
f. SEE DETAILS FOR MORE INFORMATION.
g. PROVIDE SAMPLE FOR APPROVAL PRIOR TO APPLICATION.
2. PLASTER FINISH [TYP.]
a. SMOOTH “SANTA BARBRA” FINISH
b. SQUARED CORNERS [TYP.]
c. PROVIDE A WEEP SCREED [26ga MIN.] AT ALL EXTERIOR PLASTER TO
FOUNDATION CONNECTIONS. WEEP SCREED AT FOUNATION LINE
d. ELASTOMERIC PAINT
e. SEE GENERAL NOTES ABOVE FOR MORE FINISH AND INSTALLATION
INFORMATION
f. SEE DETAILS FOR MORE INFORMATION.
g. PROVIDE SAMPLE FOR APPROVAL PRIOR TO APPLICATION.
3. CONCRETE FINISH (TYP)
a.
4. ALUM FRAME FIXED GLASS WINDOW TYPICAL; SEE WINDOW SCHEDULE
FOR ADDITIONAL INFORMATION.
5. ALUM FRAME SLIDING GLASS DOOR TYPICAL; SEE DOOR SCHEDULE FOR
ADDITIONAL INFORMATION.
6.
7. OVERHEAD DOOR - SEE DOOR SCHEDULE
8. METAL DOOR - SEE DOOR SCHEDULE
9. 4" high BRUSHED ALUM. LETTERS ON "CORTEN" BACKGROUND. NUMBERS
SHALL BE ILLUMINATED BY A TIME CLOCK CONTROLED LIGHT.
10. Fireplace
chimneys
shall
extend
at
least
2
feet
higher
than
any
portion
of
a
building
within
10
feet,
but
shall
not
be
less
than
3ft
above
the
highest
point
where
the
chimney
passes
through
the
roof.
(R1003.9
CRC)
11. EXT PLASTER CHIMNEY
a. PLASTER FINISH - “MACHINE DASH” FINISH
b. CHIMNEY CAP - SEE DETAILS
12. METAL FASCIA "PAINT LOC" 20 GA
13. RAISED PLANTER
14. CASEMENT WINDOW - SEE WINDOW SCHEDULE
15 "COR TEN" METAL SIDING
Rear Elevation
Front Elevation
Right Side Elevation
Left Side Elevation
13
7
3
15
4
3
5 315
4
13
11
1
1
3
1
114
455 5
3
1
3 11
54 1
4
14
3 1
4
3
1
1
1
1
1
3
8
1
1
34
4
1
9
1
SEE SECTIONS FOR BUILDING HEIGHTS
Scale: 1/4"=1'-0"
Scale: 1/4"=1'-0"
Scale: 1/4"=1'-0"
Scale: 1/4"=1'-0"
FINISHES
Fascias Smooth "Santa Barbra Stucco Finish
Walls Medium "Dash Coat" Stucco Finish On Wood Frame
Exposed Concrete "ICF Walls"
Stucco over "ICF wall" Medium Dash Finish
"Cor Ten" Horizontal 6" Siding
Trim Wood Stained w/ Polyeurethane Finish
Door Painted Door to Match Fixed Panel Above
Glass Fixed Glass
Sliding Glass Door
77-318
8'-6"